Loading...
0210-174 (SFD)H 04 w �Lf` Oz CD 0-6 F- W W I- a N Z D LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ "- Liceq §e #s Lic. Class 'I ! / . Exp. Date 1 6o 73 Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, -Business & Professionals Coclej 2 <`� 1 .ale.: rj�- () I am exempt under Section , B&P.C.'for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations s() I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier - ;Nrathk}';f+1DON RATIO Policy No. BMT01761201 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers,' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of'Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety, for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to '++ any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is, correct. I agree to comply with all City, and State laws relating to the building. construction, and hereby authorize •representatives of this City to enter upon' / /-- ..,✓, r..1, the above mentioned property formspecUon purposes. Sighature (OWner/Agent) Date BUILDING PERMIT PERMIT# 0210_1114 DATE VALUATION LOT TRACT JOB SITE ADDRESS x`3-035 As e�1 F{c.LA APN OWNER CONTRACTOR/DESIGNER/ENGINEER k1I}it..I3:P.RG 110 S RU LTA gG H -OR 01,18 4 2,6 00 COOK Ur. 0,120 42.600 COtqMIT. 0120 PALM DESI ,C -,Ok 92211 PALS DMM7L CA 92211 (760)340,4748 6856 USE OF PERMIT VbIXpp .rlS 1595 S.F. ,*UMIT C1f .n% NOT NICI. CI DE K.i..O6;1C WA1,14, POOL, OR DMVEWAYAPMOACH TRACT CONSTRUCTION 1,49S.00 8F a9ARAQVIC A18.POWr 48.4.00 SY 1u l[7WMM C06r Oy Cr?MUCTIOtit 96.07530 CONSIITRUC°!101d FEE 101-000.418.000 026.0 PLAW CI°1WX ME 101-000-4-39-318 $519.71 Fes+ DEPOSIT 101-000-439-318 00.439-a18 .-SH40.09 _ MFf_HANI(,L 11ZE 101-•000-421.000 $52.50 HurCT MCAL FEE 101-000-420°_01.00 $113,90 PlIU1t BINO F", 101-000-419-01)0 $113.00 i LOI40 M0,F))ON 1`'11, • 'f i`i) 7.01.000-V"I.000 "M DRADINO IM 1.01-000-123.000 $13.00 OEV.ELOPRI 7MPACT WE PRECISE PLAN ; .:,03 •GAG-4tL1 �34�i $JOEi.ltiD C°C31 " R1'F "IMT AW $.3,9 x8.87 lZM3 FRR-�PAM FEES 4250,90 t i C:1AL 1"MF+I1`fi"M DUE NOW T. T CI FINQ+NCE DEPT �• 1 :f ):IEbEIPT ,` � : DATE a P CP10 �6✓ 3Y DATE FINALED L 610 INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap •c7 3 S F.A.U. Framing . . p Compressor Insulation (.o Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall _ Exterior Lath Drywall - Int. Lath Final Final O BLOCKWALL A PROVALS Steel POOLS - SPAS Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Innes Water Piping Plumbing Top Out _ •O` % Heater Final Plumbing Final Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection o d— % Encapsulation Gas Piping_ -2,• Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) _�i COMMENTS: Building _ G1 Address (J Owner Address toi-ly =S0, MA 0, d. . l Address,C/^ e 0 v -e - City Zip T,ityl 4 P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO '/-9 Nmr�A QUINTA, CALIFORNIA 92253 BUILDING: TYPE'CONST.OCC. GRP. &' A.P. Number �-Iy — ®/ Tel. 3 �— Legal Description Project Description / (2 —On— 5In 2 S� Tel. State Lic. I City & Classif. Lic. # Arch., Engr., /f� _ C/ Designer (��[C-r/ Address Tel. S 6`O �� ,' M0 Sta CityC Lic.t# LIC ED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 13 of the Business and Professions Code, and my license is in full force and effect. a/% /w 1 SIGNATURE tI'". DATE OWNER -BUILDER DECLARATION 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to'its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or thathe is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I I I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law doesnot apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) I'! I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company rl Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of ing work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip Sq. Ft. f 5f- Size New Add ❑ -237 Estimated valuation No. No. Dw. Stories Units Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Eric._--r; -----F\I Infrast1,ructure /� iYlirily MIT-- N!l�jl Nlrl �,, 7nn� NIN111 y„y�.r IU I Lit,I L 1 LWyL ILJI TOTA tri i T Or L v, xw y v �„-� Ani re�A4 REMARKS_r ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE RC DISTRICT - PLANNING REVIEW FORM •This form is to be used by CDD staff for review of single family dwellings in the RC (Cove Residential) District per Section 9.50.090 of the Zoning Code. Its purpose is to determine: 1) . that the proposed housing design does not duplicate the same architectural style of any house within 200 feet of the applicant, and/or 2) if there is a need for the applicant to file for Master Design Guidelines. If the applicant does need to file a Master Design Guideline, please transmit this information to the Building and Safety Department as part of your correction list. Please attach additional explanations as necessary. APPLICANT: Building Horizons SITE ADDRESS: 53-035 Ave Herrera APN 774 - 053 - 013 CASE NO.: 2002-734 LEGAL: LOT 1 BLOCK 2c UNIT 2- S.C.@V.L.Q. CHECK AND APPROVED BY: Wally Nesbit DATE: Inform the assigned Building plan checker upon your assignment'to this case. The CDD Executive Secretary maintains a log book to track applications and assign case numbers. REQUIRED ITEM Y N COMMENT/CORRECTION Verify legal and APN information ✓ ©� Consistent with MDG on file (as. / applicable) MDG filing required (5 filings since 9/3/98) Architectural variety within 200 feet of the surrounding area: CID S �� Architectural design features -- - Other Requirements: r v d ° Planning City Council --- Co ase No. - - xhib it :..,..-..r..— WCertificate of Occupancy City of La Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various. ordinances of the City regulating building construction or use. For the following. BUILDING ADDRESS: 53-035 AVENIDA HERRERA Use Classification: SINGLE FAMILY DWELLING Bldg. Permit No.: 0210-174 Occupancy Group: R-3 Type of Construction:. VN Land Use Zone: RC Owner of Building: BUILDING HORIZONS Building Official Address: 42-600 COOK STREET #120 City: PALM DESERT, CA 92211 By: STEVE TRAXEL Date: 06-06-2003 POST IN A CONSPICUOUS PLACE BF,EEZE AIR CONDITIOtiING, INC. Y'7a-145 ST. CHARLES PLACE PALM DESERT, CA 92211 . PHONE: (760) 346-0855 FAY: (.760) 568-5986 LICENSE —4416394 REQtiIREyIENTS FOR TITLE 24 COMPLU CE CONTR.-kCTOPIARCHITECT: W Ltd I N �- 4 O'T<jZO !)S DATE: ADDRESS: .!9-- Ljo < CITY, STATE, ZIP: /4-t PHONE: :2L20—`-34-0— —7!IcA JOB 0— — JOB DESCRIPTION: 'Z� --,, -- C5:�t 7}�►/ );/ /./D /g P11f-P-9p-A / A-�710i,4 ,W -[—A °I? ?_ � ? Please note: Breeze Air Conditioning, Inc. has implemented the following marked boxes so the above project complies with the Title 24 requirements. WATER HEATER f ST u-iD ARD O.A. SMITH FSG 75-230 AIMERICAN PBG 102-345100-2LPV OTHER �C HVACSYSTEM X EXCPANSION VALVE ?C 6% DUCT TESTING k RADIANT BARRIER OTHER tiC ROOF R38 )c R30 OTHER WALLS R:1 <' R19 OTHER GLAZING DUAL BRONZE LOW E SQUARED DOUBLE METAL CLEAR DEFAULT DUAL CLEAR LOW E SQUARED DOUBLE METAL TINTED DEFAULT DUAL BRONZE METAL NON METAL CLEAR DEFAULT NON METAL TINTED DEFAULT OTHER U -VALUES U -VALUES S.C. OPERABLE -189 _-10 FIXED SLIDING PATIO DOORS _� O SWINGING DOORS :� D SIGHT BUILT FIXED SKYLIGHTS OTHER OTHER RESPECTFULLY, TITLE 24 REPORT Title 24 Report for: Building Horizons 53-035 Avenida Herrera La Quinta, CA 92253 Project Designer: Design Concepts 56-020 Santa Fe Trail Ste. A Yucca Valley, CA 92284 (760) 365-8742 Report Prepared By: Gina Rose BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Date: DATE % •oL BY S% 9/25/2002 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 1 • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Building Horizons . 9/25/2002 Project Title Date 53-035 Avenida Herrera La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check! Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,595 fl? Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 1,595 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition _ ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 de- Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typical, e R-30 Roof (R.30.2x12.16) Wood R-19 Wall (W.19.2x6.16) Wood Solid Wood Door None Slab On Grade n/a Slab On Grade n/a FENESTRATION 0.034 Exterior Roof 0.065 Exterior Wall 0.387 Exterior Door 0.756 Exposed Slab w/R-0.0 Perimeter Insulation 0.756 Covered Slab w/R-0.0 Perimeter Insulation Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (North) 53.4 0.85 0.70 Bug Screen ❑ Q ❑ x❑ Right (North) 32.0 0.87 0.70 Bug Screen ❑ Q ❑ Q Left (South) 28.0 0.87 0.70 Bug Screen ❑ Q ❑ Q Rear (West) 40.0 0.85 0.70 Bug Screen ❑ Q ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ El ❑❑ El El F-1 El EI 1:1 Run Initiation Time: 09/25/02 11:07:19 un Code: 1032977239 Ener Pro 3.1 B Ener Soft User Number: 3665 Job Number: Pa e:3 of 25 0 • Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Building Horizons 9/25/2002 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Slit Haat Pump 6.80 HSPF Ducts in Attic 4.2 Sethack HVAC -1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Heat Pump 10.5 SEER Ducts in Attic 42 Sethack HVAC -1 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50aa1 or cc Small Gas Standard 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Design Concepts Address: 56-020 Santa Fe Trail Ste. A Yucca Valley, CA 92284 Telephone: (760) 365-8742 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: • Telephone: EnerpvPro 3.1 By EnergvSo User Number. 3665 (date) Name: Gina Rose Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 �–Y— k?, (signature) (date) Job Number: of 25 Certificate of Compliance: Residential (Addendum) CF-1 R Building Horizons 9/25/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special Iustitication and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC.approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:5 of 25 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into . the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 0 11 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X '§ 150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. * §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X not apply to exterior mass walls). ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed: El§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:6 of 25 • E • Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) C§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. a§ 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in Kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number: Page:7 of 25 Computer Method Summary ■:.. (Part 1 of 3) C -2R -Ridirfinq Floriznns 9125120D2 Project Tie X53-035 Avenida H_prrera I a Quintn Date Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author ■ Telephone Plan Check/Date Cm liter Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.49 3.53 -0.04 Space Cooling 38.13 36.05 2.08 Domestic Hot water 15.11 15.11 0.00 Totals 56.73 54.69 2.04 BUILDING COMPLIES GENERAL INFORMATION X❑ Slab Floor Conditioned Floor Area: 1,595 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Total Fenestration Area: 9.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 14,355 Number of Stories: 1 Slab Floor Area: 1,595 BUILDING ZONE INFORMATION Zone Name # of Floor Area Volume Units Zone Type HVAC -1 1 595 14455 1 n0 Cnnditinned OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Boos_ 1.595 0.034 0 0 Wales 3.1 —0_0.6 0_ 9Q Wall _248 90 90_ Door 20 0.3BZ 9Q go .Door 20 0387 90 90 Wall 388 0.065 180 gn Wall 248 0.065 270 go • Solar Gains Y / N Form 3 Reference ►/ ■:.. ff1;1W9WJ1,%vA -1 MR -n- rRVATA /� ■ � 1TY 9WOM51.0 ■ ■ ■ ■ ■ ■ Thermostat Vent Type Hgt. Area Sathack n/a Location / Comments Fntire Residence Entire Residence Fntire Residence Fntire Residence Entire Residence Fntira Residence Fntire Residanra L_ EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:8 of 25 1 Computer Method Summary (Part 2 of 3) C -2R Building Horizons 9/25/2002 -Proiect Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _L Window Right Orth) 53.4 --USD- D- 0.70 0 q0. Double Metal Clear Default Entire Recidenae 2 Window Right (North) 16.0 0.870 0.70 0 90 Double Metal Clear Default Entire Residence 3 Window Right (North) 16.0 0.870 0.70 0 90 Double Metal Clear Default Entire Residence 4 Window Left (South) 16.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 5 Window Left (South) 9.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 6 Window Left (South) 3.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 3 Window Rear (West) 40.0 0,850 0.70 270 90 Double Metal Clear Default Entire Residence EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paoe:9 of 25 1 INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paoe:9 of 25 1 Computer Method Summary (Part 3 of 3) C -2R Building Horizons 9/25/2002 -Proiect Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 42 0.76 0.0 0 Entire Residence -Slab Perimeter 124 x.76 0.0 _0 Entire Residence HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments -Split Heat Pump 6.80 HSPF Ducts in Attic 4.2 Setback HVAC -1 *Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Heat Pump 10.5 SEER Ducts in Attic 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40.000 50 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Building Horizons 9/25/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies used on the adequacy of the special justification and documentation submitted. Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC Svstem "HVAC -1" includes credit for a Radiant Barrier installed Der Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEG approved HERS provider. me KF -R5 rater must document the field verification and diagnostic testing of these measures on a form GF -6R. Plan Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 11 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME - DATE Building Horizons 9/25/2002 SYSTEM NAME FLOOR AREA HVAC -1 1,595 HEATING SYSTEM PSYCHROMETRICS (Airs1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAR CFM Sensible Latent CFM I Sensible 1,877 29,826 5,509 2,119 31,032 59.2/57 . 7 OF 0 ROOMS 1,491 1,552 0 0 96 4,133 1,049 96 4,440 0 0 1,491 1,552 36 942 6 558 LENNOX HP29-060/CB29M-65 38,894 9,956 Total Adjusted System Output 38,894 9,956 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 26.0 OF 67.2 OF ■ 84.4 OF Outside Air 96 cfm Heating Coil 69.3 OF 38 575 36,830 36,830 Jan 12 am 84.4 OF Supply Air ucts �FO�k Supply Fan 83.7 OF 2000 cfm ROOMS 70.0 OF Retum Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I 115.0 / 78.4 OF 76.6 / 64.8 °F. 58.5 / 57.4 OF 58.5 / 57.4 OF Outside Air 96 cfm 74.7/64.0 °F Cooling Coil I.. 'a zO;r: Supply Air Ducts Supply Fan 59.2/57 . 7 OF 2000 cfm ROOMS 57.7% R.H. 74.0/63.8°F Return Air Ducts ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Pane: 12 of 25 1 4 4 ROOM LOAD SUMMARY PROJECT NAME Building Horizons DATE 9/25/2002 YSTEM NAME HVAC -1 FLOOR AREA 1,595 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Entire Residence Entire Residence 1 1,877 29,826 5,509 1,877 29,826 5,509 2,119 31,032 PAGE TOTAL 1 1,877 29,826 5,509 2,119 31,032 TOTAL 1 1,877 29,826 5,509 2,119 31,032 EnergyPro 3.1 By Ener ySoft User Number. 3665 Job Number. Page: 13 of 25 ROOM HEATING PEAK LOADS Project Title Date Building Horizons 9/25/2002 Room Information Design Conditions Room Name Entire Residence Time of Peak Jan 12 am Floor Area 1,595 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr FJ Clear 1,595.0 x x x x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X 0.0341 X x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 = — = = — = = — = = = = = = = — = — = = = = = = = = = — = = = = — — = = = = — 2,390 1,214.6 0.0655 44.0 3,498 93.4 0.8500 44.0 3,493 60.0 0.8700 44.0 2,297 40.0 0.3872 44.0 682 perimeter = 166.0 44.5 7,387 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 19 746 Infiltration: I 1.00 x 1.072 x 1 595 x 9.00 x 1.00 / 60] x 0 0 11 286 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 31 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:14 of 25 • L -J 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Building Horizons 9/25/2002 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Entire Residence 740F 116DF 420E Conduction Area U -Value DETD 1 Btu/hr X (North) 59.0 = 3,205 X A 38.6 = 3,069 X (West) 42.0 = 3,334 X 187 42.0 = 2,192 X 0.779 38.6 = 598 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 12 398 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr E (North) North A (North) A (South) B C (South) (South) D (West) 1 16.0 15) 0.779 ( 0.0 X1 X x x x X x x x + + + + + + + + + 53.4 x X X x x x x x x 15) X X x x )x )x 0.779 = = = = = = = = 624 ( 0.0 1 16.0 15) 0.779 187 ( 0.0 1 16.0 -15)x 0.779 187 ( 0.0 1 16.0 32) 0.779 399 ( 0.0 1 9.0 32) 0.779 224 ( 0.0 1 3.0 32)X 0.779 75 ( 0.0 1 40.0 73)X 0.779 2 275 ( ( -- Sched. Page Total 3,972 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,595 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Occupants 1.00 X 1,595 X 250 Btuh/occ. / 250 sgft/occ. = 1 595 Receptacle 1.00 x 1,595 X 0.200 Wafts/sqft x 3.413 Btuh/Waft = 1 089 Process 1.00 x 1,595 x 0.000 Watts/sgft x 3.41 Btuh/Waft = o Infiltration: �� x � x 5g x x � / 60] 42 = Schedule Air Sensible Area Ceiling Height ACH z:�T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29826 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 595 x 2001 Btuh/occ. / 250 sgft/occ. = 276 Receptacle 1.00 x 1 595 x 0.000 Wafts/sqft X 3.41 Btuh/Waft = 0 Process 1.00 x 1 595 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = 0 Infiltration: 1 1.00 x 4 806 x 1 59 x 9.00 X 1.00 / 60] 1 0.00368 = 4 233 chedule Alr Latent Area Ceiling Height ACH\yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,509 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 15 of 25 0 ENGINEERING DATA V 011 CB29M ELITE 10'm MULTI -POSITION BLOWER -COIL Cooling Capacity - 12,600 to 60,000 Btuh (3.7 to 17.6 kW) Heating Capacity (Heat Pump) - 11,500 to 58,000 Btuh (3.4 to 17.0 kW) Optional Electric Heat - 2.5 to 30.0 kW Bulletin No. 210105 September 2000 C U UL Supersedes November1997 0 O LISTED LISTED Typical Applications Up -Flow Installation With Optional Electronic Air Cleaner 40 0 Horizontal Installation CB29M Horizontal Left Hand Position (With Optional Electric Heat) CB29M Up -flow Position (With Optional Electric Heat) Down -Flow Installation CB29M- 41-1 Unit Type �— .Minor Revision Number CB - Blower / Evaporator Coil Nominal Cooling Capacity 21/26 - 1.5 to 2 tons (5.3 to 7.0 kW) Series 31 - 2.5 tons (8.8 kW) 41 - 3 tons (10.6 kW) Configuration 46 - 3.5 tons (12.3 kW) M - Multi -Position 51 - 4 tons (14.1 kW) 65 - 5 tons (17.6 kW) NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. nc2000 Lennox Industries Inc. SPECIFICATIONS Model Number C829M-21/26 CB29M-31 CB29M-41 CB29M-46 C829M-51 CB29M-65 Nominal cooling capacity -tons (kW) 1-5 - 2 2.5 (8.8) (5.3 - 7.0) 3(10.6) 3.5 (12.3) 4(14.1) 5 (17.6) Net face area - I'Le (m) 3.11 (0,29) 3.56 (0.33) 4.44 (0.41) 5.0 (0.46) cfm Tube outside diameter - in. (mm) Watts 3/8(9.5) Lls Watts aporator Number of rows 2 .00 0 3 570 Coil Fins per inch (fins per m) 14 (551) 400 980 12 (472) 370 .05 Suct. (vapor) line conn. - in. (mm) sweat 5/8 (16) 3!4 (19) 7/8(22.2) 1-1l8 (28) 1100 Liquid line conn. - in. (mm) sweat 395 3/8(9.5) 460 370 Condensate drain connection (fpt) - in. (mm) 25 (2) 3/4 (19) 560 440 Refrigerant 515 HCFC -22 975 460 Blower wheel nominal diameter xwidth - in. (mm) 10 x 7 (254 x 178) 10 x 8 1 (254 x 203) 10 x 9 (254 x 229) 11 1/2 x 9 (292 x 229) Blower motor output - hp (W) 1/5(149) 1 1/3(249) 1/2 (373) 314 (560) ttNumber and size of filters In. (1) 15 x 20 x 1 20 (1) 20 x 20 x 1 1150 mm (1) 381 x 508 x 25 (1) 508 x 508 x 25 425 Electrical characteristics (60hz) 208/230v-1 ph 2T460v-3 ph i�460v-3 ph 208/230v-1 ph r,460v - 3/ph, IT575v - 3 h p p Shipping weight - lbs. (kg) 1 package 121 (55) 1 123 (56) 156 (71) 160 (73) 181 (83) 1 181 (83) OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA 495 370 940 Side Return Unit Stand (Up -Flow Only) Catalog number 451<31 75 451<32 520 Ship. wt. - lbs. (kg) 5 (2) 6 (3) 1020 Wall Hanging Bracket Kit - Shipping weight - lbs. (kg) 360 451<30 - 3T1) (Up -Flow Only) 435 330 Down -Flow Combustible Base - Ship. wt. - lbs. (kg) 34,172 - 8 (4) 1035 34,173 - 8 (4) 390 960 ECB29 2.5 ::,Output - Btuh (kW) 9,500 (2.8) 10,000 (2.9) - - - - - - - - - - - - 125 -<AFUE 100% 100% ---- ---- ---- ---- 370 ECB29 5, ECB29-5CB `5 -Output - Btuh (kW) 18,000 (5.3) 19,000 (5.6) 19,000 (5.5) 20,000 (5.8) 20,000 (5.8) 20,000 (5.8) -xAFUE 100% 100°0 100% 100% 100% 100% 410 ECB29-6 ECB29-6C6 -Output - Btuh (kW) 21,500 (6.3) 22,000 (6.4) 22,500 (6.6) 22,500 (6.6) 23,500 (6.9) 24,000 (7.0) xAFUE 100% 100% 100% 100% 100% 100% 760 ECB29-8, ECB29-BCB.rAFUE YOutput Stuh (kW) 28,000 (8.2) 29,000 (8.5) 29,000 (8.5) 30,000 (8.7) 30,000 (8.7) 31_1000(9. 1 100°I° 100% 100°f° 100% 100% 100% lectric ECB29-9, ECB29-9CB [;Output - Btuh (kW) 32,000 (9.4) 33,000 (9.6) 33,000 (9.6) 34,000 (9.9) 34,000 (9.9) 34,500 (10.1) *AFUE 100% 100% 100% 100% 100% 100% eat apacity ECB29-10, ECB29-1006TAFUE aOutput - Btuh (kW) 35,000 (10.3) 36,000 (10.5) 36,000 (10.5) 37,000 (10.8) 37,000 (10.8) 37,500 (10.9) 100% 100% 100% 100% 100% 100% (1 phase) ECB29 12.5C8 MOutput - Btuh (kW) - - - - 44,500 (13.0) 44,500 (13.0) 45,500 (13.3) 45,500 (13.3) 46,500 (13.6) *AFUE - - - - 100% 100% 100% 100% 100% ECB29-15CB MOutput - Btuh (kW) - - - - 53,000 (15.5) 53,000 (15.5) 54,000 15.8) 54,000 (15.8) 55,000 (16.1) :zAFUE ---- 100610 100% 100% 100% 100% ECB29-20CB MOutput - Btuh (kW) - - - - - - - - 70,500 (20.6) 71,500 (20.9) 71,500 (20.9) 72,000 (21.1) :rAFUE ---- ---- 100% 100% 100% 100% ECB29 25C6 ',Output - Btuh (kW) - - - - - - - - - - - - 88,00 0 (25.8) 89 ,000 (26.1) *AFUE ---- ---- ---- ---- 100% 100% ECB29-3008 Output - Btuh(kW) -.-- ---- ---- ---- 106,000 (31.0) *AFUE ---- - ---- 1 100% *Annual rues utilization Ettictency based on U.S. DOE test procedures and according to FTC labeling regulations. $Disposable frame type filter fumished. LTIBlower motor is 460v - 1 phase. Optional electric heat is 460v - 3 phase. M. Blower motor is 460v single phase. Order 575v Transformer Kit (661(90) or 575v electric heater (heaters shipped with 575v to 460v step-down transformer for use with 460v units. MIncludes additional blower motor heat caoacitv. External Air volume ana motor watts at Static I Specific Blower Taps Pressure I High I Medium I Low in, w.g. I Pa I cfm j ljs�__j Watts I cfm I Us I Watts I cfm s I Watts NOTE - All air data is measured external to unit with air filter in place. Electric heaters have no appreciable air resistance. :1329M / Page 4 ► External Static Air Volume and Motor Watts at Specific Blower Taps Pressure High Medium Low in, w.g. Pa cfm L/s Watts cfm Lls Watts cfm Us I Watts .00 0 1210 570 445 1105 520 400 980 465 370 .05 10 1200 565 445 1100 520 395 980 460 370 .10 25 1185 560 440 1095 515 390 975 460 365 .15 35 1170 550 430 1080 510 385 965 475-5-360 20 50 1150 540 425 1065 500 375 955 450 350 .25 60 1125 530 420 1045 495 370 940 445 340 .30 75 1100 520 410 1020 480 360 920 435 330 .40 100 1035 490 390 960 455 335 870 410 310 .50 125 955 450 370 890 420 315 805 380 285 .60 150 865 410 350 800 380 290 725 345 260 70 175 760 360 325 695 330 265 635 300 235 -77-5-1-85 705 1335 1 315 640 1300 1 250 1580 275 225 NOTE - All air data is measured external to unit with air filter in place. Electric heaters have no appreciable air resistance. r, LINE VOLTAGE LOW VOLTAGE (70) INLETS INLETS CB29M-21126 I CB29M UP -FLOW POSITION (Top and Left Side) (Top and Right Side). I 1-3/4 SUPPLY AIR DETAIL OF PIPING PLATE 3/4 OPENING _1_ . — — — — — — — — _ (19) 49-1/4 1-118 (29) 52-1/2 1334 B SUCTION. LINE 4-318 (111) CONDENSATE 3/4 3/4 LIQUID DRAINS (2 (Horizontal (19) 11-1 16 (281) (19) f LINE 20-5/8 D / ELECTRIC , '- 2 O 14-3/4 AIR FLOW (511 502 19-3/4 502 E O CONDENSATE I 483 - 483 DRAINS (2) 533 F . 5-318* (Up-Flow and I 20 u —14 , -_. - (137) + ' s2-314 �- + Down -flow) LINE VOLTAGE LOW VOLTAGE (70) INLETS INLETS CB29M-21126 I CB29M-51 _ CB29M-65 (Top and Left Side) (Top and Right Side). I 1-3/4 I TOP VIEW L — (44) 3-1/2 (89) — — mm B� 5/8 A 45-1/4 1149 49-1/4 1251 52-1/2 1334 B 16-1/4 413 21.-1/4 540 21-1/4 7--J OPTIONAL /BLOWER)`" 524 20-5/8 524 / ELECTRIC I D 14-3/4 AIR FLOW HEAT (Field. 502 19-3/4 502 E Installed) 483 19 483 21 533 F 15 381 20 508 20 508 TOP VIEW L — (44) 3-1/2(89) — gACCESS FILTER 1-4— C-01 /. / PIPING V. `' I:. I / SUCTION - I` COIL' FILTER - — PLATE / LINE \ I, " _• gig. I' FILTER 1CCESS . I / . — — q' - / LIQUID LINE 518 PLATE_ FILTER 5/8 RetuE Al 5/ Return Air (16) FRONT VIEW (16) (25)1 SIDE VIEW (166 ) Model odCB29M-31 CB29M-21126 CB29M-41 CB29M-46 CB29M-51 _ CB29M-65 inch mm inch mm inch mm A 45-1/4 1149 49-1/4 1251 52-1/2 1334 B 16-1/4 413 21.-1/4 540 21-1/4 540 C 20-5/8 524 20-5/8 524 22-5/8 575 D 14-3/4 375 19-3/4 502 19-3/4 502 E 19 483 19 483 21 533 F 15 381 20 508 20 508 DETAIL OF PIPING PLATE CB29M DOWN -FLOW POSITION r%1!6(2s> — — — — —1 Model Model CB29M-21/26 CB29M-31 CB29M-41 CB29M-46 CB29M-51 CB29M-65 inch mm inch mm inch mm A 45-1/4 1149 49-1/4 1251 52-1/2 1334 B 16-1/4 413 21-1/4 540 21-1/4 540 C 20-5/8 524 20-5/8 524 22-5/8 575 D 14-3/4 375 19-3/4 502 19-3/4 502 E 19 483 19 483 21 533 F 15 381 20 508 20 508 FRONT VIEW SIDE VIEW CB29M / Page 11 O. � SUCTION•LINE� . 1.., - ` 58 LIQUID.,DRAINS (4,3/8 ,F CONDENSATE f (2 ' UN_ E (Horizontai� I 5/8 5/8 O. F .= 011 V- %� i {,`RETURN- E:`' AIR .`.._ ' �• ..Q` - CONDENSATE DRAINS (2) I OPENING.! -"- - z ; ° S.3/8- + + (Up -Flow and DOWn-fIOW ) - - 2-W4' ' ' (70). LUJ (25) I _e 1-3/4 �( I TOP VIEW L — (44) 3-1/2(89) — gACCESS FILTER 1-4— C-01 FILTER - — V l -,l SUCTILINON I COIL.. I. PLATE_ /:! 9 I — — LIQUID — — — — LINE— I— _ I r A OPTIONAL ELECTRIC f` ^' AIR FLOW.I. (Fie .. I dd I SLOWER)' Installed) , 1 LOW VOLTAGE • (Rl% Side) LINE VOLTAGE (Left Side) _ — — nuuuuunm .n nnuuunuw. 518 � Supply Air (i6 I _Supply Air 3/4 3/4 D��314 11 1.1/18 1� (19) (19) (19) (2811 FRONT VIEW SIDE VIEW CB29M / Page 11 O. HEAT PUMP OUTDOOR A] H P29 ELITE 11 Tm SERIES •ENGINEERING DATA SEER - 10.00 to 11.30 ` CSAiw VERIFIED Cooling Capacity - 17,900 to 58,000 Btuh (5.2 to 17.0 kW) ENERGPERFORM NCE Heating Capacity - 16,600 to 56,000 Btuh (4.9 to 16.4 kW) _ Bulletin No. 210073 September 2000 �f �\ Supersedes June 1997 CERTIFICATION APPLIES ONLY %"EN TME COMPLETE SYSTEM IS LISTED WITH API S LISTED CS LISTED Typical Application MODEL 1 1 HP29 -036 -1 Y Unit Type--=— T Vottage HP = Heat Pump Outdoor Unit P = 208I230v-1 phase-60hz Y = 208t230v-3 phase-60hz Series G = 460v-3 phase-60hz Cooling Capacity Tons (kW) J = 575v-3 phase-60hz 018 = 1.5 (5.3) Minor Revision Number 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 042 = 3.5 (12.3) 048 = 4 (14.1) 060 = 5 (17.6) 7Heating o 11.30. O.P. up to 3.00. o 8.00 (Region IV). - 1.5 through 5 Ton (5.3 through 17.6 kW) sizes. - Single or three phase power supply. - Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. - Matching up -flow, down -flow and horizontal blower coil units with supplemental electric heat provide a wide range of cooling and heating capacities and applications. See ARI Ratings table for match -ups. - Also applicable to indoor add-on coils matched with conventional furnaces with FM21 Heat Pump Control. See bulletin indexed in Thermostats and Controls tab section. - For complete data on indoor blower coil units and FM21 coils, see tab section Blower Coil Units. - Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. - Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job. Approvals - Certified in accordance with the USE certification program, which is based on ARI Standard 210/240-94. - Sound rated in Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270-95. - Tested in the Lennox Research Laboratory environmental test room. - Rated according to U.S. Department of Energy (DOE) test procedures. - Outdoor units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. - Units are UL and ULC listed. - Developed in accordance with ISO 9000 quality standard. Equipment Warranty - Compressor — Ten years (residential applications), five years (non-residential applications). - All other covered components — five years (residential), one year (non-residential applications). - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ©2000 Lennox Industries Inc. ' Installation and service must be performed by a qualified installer and servicing agency. OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA Check and Expansion Valve Kits Must be ordered extra and field installed on certain indoor coil units. See ARI Ratings table for kit selection. Crankcase Heater (Optional for 030-036-042-048-060 Models) - Prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. Hail Guards - Constructed of louvered heavy gauge steel painted to match cabinet. - Surrounds unit on all four sides to prevent damage to the coil. - See Specifications table for catalog number. Low Ambient Kit - Heat pump units operate satisfactorily in the cooling mode down to 45 OF (7`C) outdoor air temperature without any additional controls. - Low Ambient Control Kit can be field installed, allowing cooling operation down to 30°F (-1 °C). Mounting Base - High density polyethylene mounting base is lightweight, sturdy, sound absorbing and will withstand the effects of sun, heat, cold, moisture, oil and refrigerant. - Provides permanent foundation for outdoor units. - See Specifications table. Outdoor Thermostat Kit - Outdoor thermostat can be used to lock out some electric heating elements on indoor units where two stage control is applicable. - Outdoor thermostat maintains heating load on low power input as long as possible before allowing full power load to come on line. - Thermostat kit and mounting box must be ordered extra. - See Specifications table. Refrigerant Line Kits - Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. - Suction line fully insulated. - L15 lines are stubbed at both ends. - See Refrigerant Line Kits table for selection. - Not available for HP29-060. Thermostat - Thermostat not furnished with unit. See Thermostats bulletin in Thermostats and Controls Section and Lennox Price Book. Unit Stand -Off Kit - Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. - See Specifications table. Compressor Monitor (Optional for Canada Only) - Compressor monitor can be field installed. - Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F (20C). - See Specifications table. Monitor Kit (Optional for Canada Only) - Field installed Monitor Kit includes ambient compensating thermistor and service light thermostat. Thermistor reduces thermostat droop to improve the operating characteristics of the heat pump system. - Service light thermostat allows operation of the service light on the indoor thermostat. - See Specifications table. Model No. HP29-018 HP29-024 HP29-030 HP29-036 HP29-042 HP29-048 HP29-060 Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Liquid line - in. (mm) o.d. connection (sweat) T3/8 (9.5) 3/8(9.5) Vapor line - in. (mm) o.d. connection (sweat) 5/8(15.9) 3/4(19.1) 7/8 (22.2) 1-1/8 (28.6) Outdoor Net face area - sq. ft. (m) Outer coil 11.41 (1.06) 15.21 (1.41) 21.11 (1.96) Inner coil - - - - 5.44 (0.51) 14.50 (1.35) 20.31 (1.89) Coil Tube diameter - in. (mm) & no. of rows 5/16 (7.9) - 1 5/16 (7.9) - 1.37 5/16 (7.9) - 2 Fins per inch (m) 22 (866) 18 (709) Diameter - in. (mm) & no. of blades 18(457)-3 18(457)-4 22 (559) - 4 Outdoor Motor hp 1/6 (124) 1/3(249) Coil Cfm (L/s) 2400 (1135) 2550 (1205) 2530 (1195) 2975 (1405) 3020 (1425) 4330 (2045) Fan Rpm 1105 1110 1130 1125 1075 Watts 180 190 195 310 330 420 'Refrigerant charge furnished (HCFC -22) 4 lbs. 5 oz. (1.96 kg) 4 lbs. 4 oz. 5 lbs. 15 oz. 7 lbs. 5 oz. 8 lbs. 8 oz. 8 lbs. 15 oz. 12 lbs. 0 oz. (1.93 kg) (2.69 kg) (3.32 kg) (3.86 kg) (4.05 kg) (5.44 kg) Shipping weight - lbs. (kg) 1 package 152 (69) 161 (73). 173 (78) 1 182 (83) 190 (86) 254 (115) OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA Outdoor Thermostat Kit Thermostat Kit LB-29740BA (56A87) Mounting Box M-1595 (31461) or BM -10260 (33A09) (Canada Only) Crankcase Heater - - - - 90P12 Low Ambient Kit LB-57113BM (27J00) Hail Guards 171-71 171-73 171-74 Unit Stand -Off Kit 94J45 Mounting Catalog No. - Ship. weight 69J06 - 6 lbs. (3 kg) 69J07 15 lbs. (7 kg) Base Dimensions in. 22-1/4 x 22-1/4 x 3 32 x 34 x 3 mm 565 x 565 x 76 813 x 864 x 76 Monitor Kit - Canada Only LB-52359CA (76F53) Compressor Monitor - Canada Only T6-1469 45F08 -FKetngerant charge sufficient for 20 ft. (6.0 m) length of refrigerant lines. t3/8 x 5/16 in. (9.5 x 7.9 mm) adaptor furnished for liquid line connection. HP29 / Pape 3 ► 0 SPECIFICATIONS LINE KITS of I Line Set Lines f Model No. ft. m Liquid Line Outside Dia. Model No. HP29-036 HP29-042 HP29-048 HP29-060 Nominal Tonnage 3 3.5 4 5 Liquid !ine -:P.. ; ^m1 o.d. connection (sweat) .318(9.5') HP29-018 Vapor line - in. (mm) o.d. connection (sweat) 3/409.1) 7/8(22.2) 1-1/8 (28.6) Net face area Outer coil 15.21 (1.41) 21.11 (1.96) Outdoor sc. ft. (m2) Inner coil 5.44 (0.51) 14.56 (1.35) 20.31 (1.89) Coil I Tuba diameter - in. (mm) & no. of rows 5/16 (7.9) - 1.37 5116 (7.9) - 2 Fins per inch (m) 22 (866) 18 (709) Diameter - in. (mm) & no, of blades 18(457)-4 122(559)-4 Outdoor ivlotor hp 1/6(124) 1/3(249) Coil I Cfm (L/s) 2500 (1180) 3020 (1425) 4330 (2045) Fan ;Rpm 1100 1125 1075 `Naas 200 330 420 'Refrigerant charge furnished (HCFC -22) 6 lbs. 3 oz. (2.81 kg) 7 lbs. 13 oz. (3.54 kg) 8 lbs. 15 oz. (4.05 kg) 12 lbs. 0 oz. (5.44 kg) Shipping weight - lbs. (kg) 1 package 193 (88) 199 (90) 190 (86) 254 (115) OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA 7.9 Outdoor Thermostat Kit Thermostat Kit LB -297406A (56A87) Mounting *Box M-1595 (31461) or BM -10260 (33A09) (Canada Only) Hail Guards 171-73 171-74 Low Ambient Kit LB-57113BM (27J00) .92 Crankcase Heater 90P12 Outdoor Coil Fan Motor Unit Stand -Off Kit 94J45 Mounting Base Catalog No. - Ship. wt. 69J06 - 6 lbs. (3 kg) 69J07 - 15 lbs. (7 kg) Dimensions - in. (mm) 22-114 x 22-1/4 x 3 (565 x 565 x 76) 32 x 34 x 3 (813 x 864 x 76) Monitor Kit - Canada Only LB-52359CA (76F53) Compressor Monitor - Canada Only T6-1469 (45F08) HP29-042 Retngerant cnarge sunicient for 2u n. (b.0 ml length of retngerant fines. DATA - I PHASE LINE KITS of I Line Set Lines f Model No. ft. m Liquid Line Outside Dia. Vapor Line Outside Dia. in. mm in. I mm HP29-018 HP29-024 L15-21-20 20 6 Model No. HP29-018 HP29-024 I HP29-030 HP29-036 HP29-042 HP29-048 jJ HP29-060,A Line voltage data - 60 hz Si16 7.9 3/4 19 208/236v - 1 ph Ll 5-31-40 40 ) 12 1-15-31-50 50 15 HP29-036 _ Rec. maximum fuse or circuit breaker size (amps) 15 3/4 20 30 35 40 50 L15-65-30 30 9 60 'Minimum circuit ampacity I 11 22.2 13.8 19.5 21.1 26.5 31.5 1 9.5 37.4 Compressor Rated load amps 7.9 10.1 14.7 16 20.3 I 23.7 28.8 I Power factor .97 .96 .90 .91 .89 .96 I .92 Locked rotor amps 49 60 84 170 127 129 169 Outdoor Coil Fan Motor I Full load amps 1.1 1.9 I Locked rotor amos 1.9 4.1 ELECTRIC -AL. DATA -3 PHASE Model No. HP29-036 HP29-042 HP29-048 HP29-060 Line voltage data - 60 hz - 3 phase 208/230v 460v 1208/230v 460v 12081230v 460v 575v 208/230v 460v 575v Rec. maximum fuse or circuit breaker size (amps) 2010 25 15 30 15 10 40 20 15 'Minimum circuit ampacity 14.9 7.6 17.1 8.6 18.8 10.2 8.2 23.5 12.2 9.8 Rated load amps 11.0 5.6 12.8 6.4 13.5 7.4 5.8 17.3 9.0 7.1 Compressor Power factor .88 .93 .88 .86 Locked rotor amps 75 37.5 87 44 ( 120 I 49.5 I 40 137 62 50 Outdoor Coil Fan Motor Full load amps 1.1 0.55 1.1 0.55 1.9 0.90 1 0.90 1.9 0.90 Locked rotor amps 1.9 1 1.0 1.9 1. 1 4.1 1 2.1 4.1 2.1 'Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. REFRIGERANT OutdoorLength Unit Model No. LINE KITS of I Line Set Lines f Model No. ft. m Liquid Line Outside Dia. Vapor Line Outside Dia. in. mm in. I mm HP29-018 HP29-024 L15-21-20 20 6 5/16 7.9 5i8 15.9 L15-21-25 25 8 L15-21-35 35 11 1-15-21-50 50 15 HP29-030 L15-31-20 20 o Si16 7.9 3/4 19 1-15-31-30 30 9 Ll 5-31-40 40 ) 12 1-15-31-50 50 15 HP29-036 15-11-20 20 6 3/8 9.5 3/4 19 L15 -f1-30 30 9 -L15-41-50 15140 40 12 FT 50 15 HP29-042 HP29-048 L15-65-30 30 9 3/8 9.5 7/8 22.2 L15-65-10 40 12 L15-65-50 50 15 H Field Fabricate 1 3/8 1 9.5 I 1-1/8 28.5 HP29 / Page 4 ► One of the coil sides adjacent to control box must be 30 in. (762 mm) for service. One of the remaining sides may be 12 in. (914 mm) One of the remaining sides may be 6 inches (305 mm) NOTE - 48 in. (1219 mm) clearance required on top of unit. NOTE - 24 in. (610 mm) required between two units INLET AIR 4-318 4-318 INLET AIR (111) (111) INLET AIR TOP VIEW 4-3/8 (111) OPTIONAL UNITU f U INLET STAND-OFF KIT (4) / CQMPRESSbR (Field Installed) AIR COIL DRAIN OUTLETS (Around perimeter of base) r� 6-3/8 VAPOR LINE (162) CONNECTION \ LIQUID LINE CONNECTION 6-3/8 4-3/8 (162) (111) TOP VIEW BASE SECTION CC OUTDOOR DISCHARGE ■ AIR COIL FAN .,. -V. t-ly) COMPRESSOR VAPOR & LIQUID LINE CONNECTION ELECTRICAL INLETS 2-3/4 (70) 1) OPTIONAL UNITSIDE VIEW STAND-OFF KIT (4) (Field Installed) Model No. A B C HP29-018 HP29-024 in. 25 24-1/4 F 7HERMOSTATI FD ISCONNECT, [DISCONNECT, 616 HP29-030, HP29-036 HP29-042, HP29-048 in, SWITCH I_ (Optional)) (gY Others) I-- SWITCH Others) LENNOX OPTIONAL A— Two Wire Power see Electrical Data ( ) HP29-060 — —� (ay I— — — --( / SUPPLEMENTAL B — Two or Three Wire Power (size to heater capacity t O ELECTRIC. HEAT A �J C — Two Wire Power (size to indoor coil blower motor) E rouT 14A D — Two Wire Low Voltage — 18 ga. minimum ITHERMOSTATI F D E — Eight Wire Low Voltage — 18 ga. minimum —with Electric Heat — Ten Wire Low Voltage with Optional Outdoor Thermostat DISCONNECT LENNOX SWITCH- I (Others F — Four Wire Low Voltage — 18 ga. minimum OUTDOOR UNIT C LENNOX. INDOOR UNIT . G — Three Wire Low Voltage — 18 a. minimum 9 g — Field bring Not Fumished — G All wiring must conform to NEC or CEC and local electrical codes. INLET AIR 4-318 4-318 INLET AIR (111) (111) INLET AIR TOP VIEW 4-3/8 (111) OPTIONAL UNITU f U INLET STAND-OFF KIT (4) / CQMPRESSbR (Field Installed) AIR COIL DRAIN OUTLETS (Around perimeter of base) r� 6-3/8 VAPOR LINE (162) CONNECTION \ LIQUID LINE CONNECTION 6-3/8 4-3/8 (162) (111) TOP VIEW BASE SECTION CC OUTDOOR DISCHARGE ■ AIR COIL FAN .,. -V. t-ly) COMPRESSOR VAPOR & LIQUID LINE CONNECTION ELECTRICAL INLETS 2-3/4 (70) 1) OPTIONAL UNITSIDE VIEW STAND-OFF KIT (4) (Field Installed) Model No. A B C HP29-018 HP29-024 in. 25 24-1/4 24-1/4 mm 635 616 616 HP29-030, HP29-036 HP29-042, HP29-048 in, 33 32-1/4 24-1/4 mm 838 819 616 HP29-060 in. 1 37-1/4 36-1/2 28-1/4 mm 946 927. 718 4-3/8 (111) 4-3/8 (111) 4 I ) l rvu r t - naongs ror au Sao ano css cons mcwoe an casea ano uncasea coos. ❑p Certified in accordance with the USE certification program, which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines; Cooling Ratings - 95'F (35°C) outdoor air temperature and 80°F (27°C) db/67°F (19°C) wb entering indoor coil air. High Temperature Heating Ratings - 47°F (8°C) db/43°F (6°C) wb outdoor air temperature and 70°F (21'C) db entering indoor coil air. Low Temperature Heating Ratings - 17°F db/15`F wb outdoor air temperature and 70°F (21 °C) db entering indoor coil air. ® Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. i� Most popular blower coil combination. t FM21 Heat Pump Control - Use coil listed with any Lenox furnace that meets system design requirements. See FM21 bulletin in Thermostats and Controls section. HP29 / Page 9 ► ❑i ARI Standard 210/240 Ratings Unit Size Model No. Check and Cool. High Low Total Total (� Sound �t Ca p' Htg. Ca Htg. Ca Total Cool. SEER Cool. High HSPF Region IV High Ht Low Low Ht Indoor Units Expansion 'ting Number Btuh (kW) gtuh Bt h Watts (EER) C.O.P. Ht Watts (Region C.O9P. Ht WaftsRequired C.O.P. Valve Kit (kW) (kW) 42,500 43,000 27,200 4775 10.50 2-61 4145 7.50 3.04 3625 2.20 Blower Coil Unit (12.5) (12.6) (8.0) (8.90) (6.50) CB30M-41 (Multi -Position) 44,000 (12.9) 43,500 (12.7) 28,20011 (8.3) 4680 00 (g 40) 2.75 4195 7.50 (6.50) 3.04 3755 2.20 Blower Coil Unit CB30U-41/46 (Up -Flow) pC830M-46 (Multi -Position) 44,000 43,000 27,200 4835 11.00 2 67 4145 7.50 3 3625 2.20 Blower Coil Unit (12.9) (12.6) (8.0) (9.10) (6.50) .04 CB31MV-41 (Multi -Position) 44,500 44,000 28,200 5115 10.30 2.55 4295 7.50 3.00 3755 2.20 Blower Coil Unit (13.0) (12.9) (8.3) (8.70) (6.50) CB29M-46 (Multi -Position) 44,500 44,500 28,600 5205 10.20 2.51 4290 7.50 3.04 3810 2.20 Blower Coil Unit Factory (13.0) (13.0) (8.4) (8.55) (6.50) C829M-51 (Multi -Position) Installed 45,000 44,500 28,400 5145 10.30 2.56 4290 7.50 3.04 3780 2.20 Blower Coil Unit (13.2) (13.0) (8.3) (8.75) (6.50) CB29M-65 (Multi -Position) 46,000 (13.5) 44,000 (12.9) 27,600 (8.1) 4840 11.30 (9.50) 2.78 3955 8.00 (7.00) 3.26 3580 2.26 ' Blower Coil Unit CB31MV-51 (Multi -Position) CB31 MV -65 (Multi -Position) Blower Coil Unit 4 Ton HP29 048 46,000 13.5 ( ) 44,000 12.9 ( ) 27,600 (8.1) 4870 11.20 (9.45) 2.77 4030 7,gp (6.90) 3.20 3610 2.24 C63OU-51 (Up -Flow) CB30M-51 ((Multi -Position) (78) CB30U-65(Up-Flow) 1 Phase CB30M-65 (Multi -Position and Indoor Coil((tFM21) LB -85759G 3 Phase 43,500 42,500 27,000 4915 10.50 2.59 4265 7.20 2.92 3695 2.14 C33 -44C U Flow 56,120 C26-46 (Up -Flow) Factory (12.7) (12.5) (7.9) (8.85) (6.30) Installed Indoor Coil ((tFM21) C33 -48C U -Flow LB -85759G 56,120 45,000 43,000 27,000 5000 10.60 2.64 4170 7.20 3.02 3595 2.20 C26-51/65 (Up -Flow) Factory (13.2) (12.6) (7.9) (9.00) (6.30) Installed 43,500 42,500 27,000 4915 10.50 2.59 4265 7.20 2.92 3695 2.14 Indoor Coil tFM21 (12.7) (12.5) (7.9) (8.85) (6.30) CR25-20-Flow) 44,500 42,500 27,000 4970 10.50 2.62 4265 7.20 2.92 3695 2.14 Indoor Coil (tFM21 (13.0) (12.5) (7.9) (8.95) (6.30) CR26-51W only (Downlow) 43,500 (12.7) 43,500 {12.7) 27,600 (g.1) 4945 10.30 (8 80) 2.58 4220 7.40 (6.40) 3.02 3675 2.20 Indoor Coil (TFM21) CH23-41 Horizontal) LB -85759G CH33-4213-� (Horizontal) (56J20) 45,000 44,000 28,000 5055 10.50 2.61 4185 7.50 3.08 3630 2.26 Indoor Coil (TFM21 (13.2) (12.9) (8.2) (8.90) (6.50) CH23-51 (Honzont 45,000 (13.2) 44,000 (12.9) 28,000 8,00 5030 10.60 (8 95) 2.62 4185 7.50 (6.50) 3.08 3630 2.26 Indoor Coil (tFM21) CH33-48C-F (Horizontal) CH23-65 ( orizontal) 55,000 55,000 35,000 6320 10.20 2.55 5970 6.80 2.70 5025 2.04 Blower Coil Unit (16.1) (16.1) (10.3) (8.70) (6.00) C829M-51 (Multi -Position) 56,000 56,000 36,000 6255 10.50 2,62 5965 6.80 2.75 5170.. 2.04 Blower Coil Unit (16.4) (16.4) (10.6) (8.95)_ (6.00) CB29M-65 (Multi -Position) 56,000 (16.4) 53,500 (15.7) 33,500 (9.8) 5895 11.00 (9 50) 2.78 5405 7.10 (6.20) 2.90 4500 2.18 Blower Coil Unit C830U-51 (Up -Flow) C830M-51 (Multi -Position) Factory 56,000 53,500 33,500 5835 11.10 2.81 5370 7.20 2.92 4460 2.20 Blower Coil Unit Installed (16.4) (15.7) (9.8) (9.60) (6.30) CB31MV-51 (Multi -Position) 58,000 55,000 35,000e 6170 11.00 275 5555 7.20 2.90 4705 2.18 r Coil Unit CB30U65(Up-Flow) (17.0) (16.1) (10.3) (9.40) (6.30) ®CB30M-65 (u-Postion) 58,000 55,000 35,000 6040 11.10 2.81 5555 7.20 2.90 4705 2.18 Blower Coil Unit r - (17.0) (16.1) (10.3) (9.60) (6.30) CB31MV-65 (Multi -Position) 5 Ton Indoor Coil (tFM21) LB -85759G HP 8 - 60- (1fi 00 566 40 6160 10.70 2.71 5660 7.20 2.90 4785 2.18 C33 -50C l! -Flow 56,120 C26-51/65 (Up -Flow) Factory go) ) ( 4) (10 ) (9'25) (6.30) 1 Installed and Indoor Coil (tFM21) LB -85759G 3 Phase 58,000 55,000 35,000 6040 11.00 2,81 5555 7.20 2.90 4705 2.18 C33 -60D U Flow 56.120 C26-65EAP (Up -Flow) Factory (17.0) (16.1) (10.3) (9.60) (6.30) Installed 55,000 55,000 35,000 6180 10.20 2.61 5925 6.80 2.72 5025 2.04 Indoor Coil (tFM21 (16.1) (16.1) (10.3) (8.90) (5.90) CR26-51Wonly (Down -low) 57,000 56,000 35,600 6160 10.70 2.71 5660 7.20 2. 90 4785 2.18 Indoor Coil (TFM21 (16.7) (16.4) (10.4) (9.25) (6.30) CR26-65W only (Down -Flow) 56,000 (16.4) 55,500 (16.3) 35,000 (10.3) 6155 10.50 (9 10) 2.67 5980 6.80 (5 90) 2.72 5025 2.04 Indoor Coil (TFM21) CH33-48C-F (Horizontal) LB 85759G CH23-51 (Horizontai) (-85759 56.120) 57,000 (16.7) 56,000 (16.4) 35,600 (10.4) 6160 10.70 (9.25) 2.71 5660 7.20 (6.30) 2.90 4785 2.18 Indoor Coil orizo ) CH3323-65 ((Horizontal) CH23-65 (Horizontal) 58,000 8,130) 55,000 (16.1) 35,000 (10.3) 6040 11.00 (9.60) 2.81 5555 7.20 (6.30) 2.90 4705 2.18 Indoor Coil (tFM21) CH33-62D-F (Horizontal) CH23-68 Horizontal rvu r t - naongs ror au Sao ano css cons mcwoe an casea ano uncasea coos. ❑p Certified in accordance with the USE certification program, which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines; Cooling Ratings - 95'F (35°C) outdoor air temperature and 80°F (27°C) db/67°F (19°C) wb entering indoor coil air. High Temperature Heating Ratings - 47°F (8°C) db/43°F (6°C) wb outdoor air temperature and 70°F (21'C) db entering indoor coil air. Low Temperature Heating Ratings - 17°F db/15`F wb outdoor air temperature and 70°F (21 °C) db entering indoor coil air. ® Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. i� Most popular blower coil combination. t FM21 Heat Pump Control - Use coil listed with any Lenox furnace that meets system design requirements. See FM21 bulletin in Thermostats and Controls section. HP29 / Page 9 ► PROGRAMMABLE MERMOSTATS (Continued) . L22 & L23 SERIES THERMOSTATS (For Heat Pump Systems Only) Model No. Description Catalog No. L221407HP .......... 2 Heat/1Cool 7 -Day .......... 91H72 L232407HP ......... 3 Heat/2 Cool 7 -Day ......... 91H73 A2000 -ROS ..... Outdoor Temperature Sensor ..... 691-127 L22 & L23 Series 7 -Day Thermostats feature full independent seven-day programming, automatic or manual changeover, built- in time delays, large easy -to -read LCD readout with actual time and temperature in °F or °C for alternating inside and outside temperature readout (with optional outdoortemperature sensor). Two stage cooling model features low or high speed cooling op- eration indicators. "Check System" indicator shows a need for service. Also features "Aux" and "Enver" indicators for supple- mental or emergency heat operation. Check filter indicator flashes at preset interval. Thermostat features system selector switch (Off -Heat -Cool -Auto) and fan switch (On -Auto) for continu- ous or intermittent blower operation. Indicator lights show "Am- ber" indicating system is operating in manual mode or (flashing) 3 hour override. "Green" light indicates system demand (turns red during emergency heat operation or flashes red indicating check system).. Solid-state electronic technology eliminates bat- tery back-up and maintains thermostat settings during powerfail- ure indefinitely. Thermostat has four separate time and tempera- ture settings per day. Individual slide switches are used to settime begin and heat and cool temperatures. "+" and "-" buttons set time of day. "Day" button sets day of week. "Prog/Review" button reviews daily programs and displays programmed time period setpoints. "Manual" button allows manual control of tempera- ture. ".Clear" button erases programmed. setpoints when repro- gramming. "Enter" button enters time of day and temperature setpoints into memory. "Enver Ht" button allows emergency heat operation. Thermostat also features adjustable lockout of supple- mental electric heat. Monitoring of compressor run times and heating times in hours and cycles is also available. Pressing front cover reviews thermostat settings. Intelligent temperature recov- ery automatically computes time to operate system to meet ther- mostat day/night settings. Optional Outdoor Temperature Sensor is also available and must be ordered extra. With optional sensor, thermostat will give a readout of present outdoor temperature and the lowest and highest outdoor temperatures of the day and times at which they occurred. —2—