Loading...
0209-182 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date ,,�121.f�fj F.. C>niOliC Date �} J Signature of Contractor—' ontractor �- OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ), I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier CjACIk..11, C�PI1Ika1' �' Policy No. t°r4oT O° "! IEC+I (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with thoseproviions. Date: �1 " ' Applicant i% ! s Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. ; 1. Each person upon whose behalf this application is made & each person' at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property -for inspection purposes. Signature (Owner/Agent) ` f'' i ` " Date BUILDING PERMIT PERMIT# DATE VALUATION LOT 02tw482 TRACT JOB SITE APN r ADDRESS Yj..055ANi�a�. OWNER CONTRACTOR / DESIGNER / EN (NEER DTMSYti'his.z',i32d€3 42-600, C 00X S'lR.iMT 42 -CM (X-) S9 ST. #120 1 AIM DEMRT CIA 912211 VALTY1D'j'+`,.S' ZT CA x+2211 (760)240.47148 CRS..$, 6856 USE OFPERMIT G dIY6jttYYNL VAIR 16,65.` . ir". SlFrl. PERI ITDnly AVS, INOT jTi4". LUDE 81=K WALL, I'G/OL OR TRACT CONSTRUCTION 11063/00 W? OAR.61.WC.ARPORT 464.00 :;fr ESFIMIAXERs'D COST (YF C0146.27ZATUXION PERM., PRE INUM i!I'A.0 Y C:ON'"STI1UC±'ION FILE 101.000.438.000 PLA'm i H.EfCA. FFIF 101-000439-31 PRE DTOSIT 101-000-439-318 4240,04 ,M,F,CHAN1CA1 .f 1J? '. 3 !J j -CtO.t -42 ..GtOt $34.00 kF.'tY.4T';UCA[. FEE 101-C3 O-WO$116,16 P L U.Y.BI'M0 FXX 101-000-419-000 3TRO NCl M0`i'.1014 FKS • RKSoID1 101.00tlja241.0(.t0 C11tiP DINO AWP, `u 1 ij'i -000-423-000 SIS. t DlaA''Es.-PsPER INV.fAC:`T F& $i jL�S,fO P11KC:IEE11LAN 103 -oat 1-345 $1.00.00 ",l�LIC;e.S�TS'�'k1,DC1J�7h1 A.�f ..t�Ja1t'i�fi'Ia n OCT 9 2 2002 1r Tf rv-Rmr YMSIWENOW 4546 1 Ciry F9OF L�4 Gi:ilr'lT "4C� :RECEIPT DATE BY DATE FI LED .03 INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings ,OY Y7 Ducts Slab Grade a - Return Air Steel Combustion Air Roof Deck a 3 15Z Exhaust Fans O.K. to Wrap -7 . p F.A.U. Framing 3_ Compressor Insulation O Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final(o d 3 BLOCKWALI A PROVALS POOLS -SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Z . Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection *0L % Encapsulation Gas Piping _ Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole 2 OZ l�`JGv Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service ' Sub Panels '= �• Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) �O COMMENTS: fel = Cv P.O. BOX 1504 ICO APPLICATION ONLY Address 3 (� -5 VP11 t ��(I COI LA QUINTA78-495 CCAL CALIALLE FORNIA 92253 Address ! f Owner / Mailing / ��/ Address �� _ C3 00 (11-, 0 � T City �� I Zip „ Tel. f Contractor Address ✓ ? City lZip Tel. State Lia City & Classif. Lic. # Arch., Engr., Designer05 ��� Address (1 `l/ ,,,Vel. el. 7J -!1 CityY (.l i`_I'rli K 411(4 I Z% .) rf i41' I Lic.t# I LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of DivisionF3,jof the Businesspnd Pr.Qfessions Code, and my license is in full force and effect. ,!/,.c'� / ��� SIGNATURE '!"/e DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). l: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ' I 1 I, asowner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law.) 1 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company [Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work. for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: It, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issue . (Sec. 3097, Ci/,I Code.) Lender's Name �`6K ^AQ k r� ! ,n Lender's Address ....JJ y� C/rf /1 i/i IG Y►� d1 (' (� � !�. 4�C This is a building permit wharf properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. r� f rr% �.Date- Mailing Signature of applicant ✓�' ^"�- Date Mailing Address I -W' CIO? f 'Qu /I �1' /[. ,7I City, State, Zip - / _ / �+ .•-� f r.. - BUILDING: TYPE'CONST. OCC. GRP. A.P. Number L/ b /�" 0/ !Y Legal Description ect Description Sq. Ft.// No. No. Dw. Size & Stories Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ Itimated Valuation PERMIT AMOUNT Plan Chk. Dep. 7 v Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback f oro Rear Prop. Line e Stree ack from Center Line S e S Property Line WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION RC DISTRICT - PLANNING REVIEW FORM •This form is to be used by CDD staff for review of single family dwellings in the RC (Cove Residential) District -per Section 9.50.090 of the Zoning Code. Its purpose is to determine: 1) that the proposed housing design does not duplicate the same architectural style of any house within 200 feet of the applicant, and/or 2) if there is a need for the applicant to file for Master Design Guidelines. If the applicant does need to file a Master Design Guideline, please transmit this information to the Building and Safety Department as part of your correction list. Please attach additional explanations as necessary. • • APPLICANT: Building Horizons Inc SITE ADDRESS: 53-055 Ave Herrera APN 774 - 053 - 014-2 CASE NO.: 2002-726 LEGAL: LOT 2 BLOCK 1A UNIT S.C.@V.L.Q. CHECK AND APPROVED BY: Martin Magana DATE: Inform the assigned Building plan checker upon your assignment to this case. The CDD Executive Secretary maintains a log book to track applications and assign case numbers. REQUIRED ITEM Y IN COMMENT/CORRECTION Verify legal and APN information Consistent with MDG on file (as applicable) MDG filing required (5 filings since 9/3/98) roved b ,. Date Reso # Architectural variety within 200 feet of the surrounding area: Architectural design features 11,P4y El Council ' Communit Dev. DeptInitiqlp. ase N0.�ot.7— chibit 'Wan Uonditions Other Requirements: 1111111113� J��ptEp 8c .o w BERMUDA DUNES r RANCHO MIRAGE O 6 INDIAN WELLS p PALM DESERT Y LA OUINTA �a INDIO L� July 22, 2002 Desert Sands Unified School District 47-950 Dune Palms Road • La Quinta. California 92253 • (760) 777-4200 Mr. Dale Wissman Executive Director Boys & Girls Club Building Horizons 42-600 Cook St., #120 Palm Desert, CA 92211 Dear Mr. Wissman: Thank you for your recent letter requesting a waiver of Developer Fees for the 2002/03 projects located at the corner of Herrera and Chihuahua in La Quinta. Desert Sands Unified School District is proud to support your organization and therefore will grant exemption of developer fees for the following locations: APN 774-053-013 — Lot 1 APN 774-053-014 — Lot 2 We look forward to collaborating with you again in the future for the benefit of the children that we jointly serve. Please call me at 760/771-8516 with any further questions or concerns. Best regards, 4-V 4 Peggy Reyes, Director of Facilities /cros BREEZE :SIR CO`+-DITIOLNLNG, ENC. /5-145 ST. CHARLES PLACE P..LM DESERT, CA 92211 -PHOLNE: (760) 346-0355 FAX: (760) -563- 936 LICE`+SE -416- 9-1 REQLTREYIE`tT5 FOR TITLE 24 COMPLIA-N CE CO`iTR-kCTOR.'.-%,RCHITECT:�UILG 1h�CS ���--��UNS DATE:'' � oOp� ,-ADDRESS: Z" 6 00 CITY. STATE, ZIP: 1') PH0NE: a 14-0 — JOB DESCRIPTIOti: S3_ OJ S Please note: Breeze Air Conditioning, Inc. has implemented the followin; marked boxes so the above project complies with the Title 24 requirements. (L , WATER HEATER STANDARD 0..-k. S-L1ITH FSG "--.30 A.:Y ERICAN PBG 102-345100-7LPV OTHER HVAC SYSTEM 1�E�vt�c"z �-�5 z�l —Cat, t/ It ® LAI+C-4/y x-! o o (!STS S) _ E`YP.�`fSION VALVE �t 6:'/o DL CT TESTENG R.A.DLAVT BARRIER OTHER X ROOF R:3 R_0 OTHER ?c WALLS R;1 k R19 OTHER >C , GLAZL`rG DUAL BRONZE LOW E SQUARED D UAL CLEAR LOW E SQUARED DUAL BRONZE I,(ETAL OTHER U -V aLL-ES U -VALUES _ OPERABLE FIXED SLM ING P.-kTIO DOORS •B �5' SWINGL.+G DOORS SIGHT BL-ILT FIXED SKYLIGHTS OTHER OTHER RESPECTY LLY, X, DOUBLE `�TAL CLEAR DEFAULT DOUBLE METAL TINTED DEF.aULT YON -METAL, CLEAR DEFAULT NON MMTAL TIINTED DEFAULT S.C. 7 e� -r0 -r-110 Certificate of Occupancy City of L.a Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS: Use Classification: SINGLE FAMILY DWELLIN Occupancy Group: R-3 Type of Owner of Building: BUILDING HORIZONS Building Official 53-055 AVENIDA HERRERA Bldg. Permit No.: 0209-182 uction: VN Land Use Zone: RC Address: 42-600 COOK STREET #120 City: PALM DESERT, CA 92211 By: STEVE TRAXEL Date: 06-06-2003 POST IN A CONSPICUOUS PLACE TITLE 24 REPORT Title 24 Report for: Building Horizons 5.3-055 Avenida Herrera La Quinta, CA 92253 Project Designer: Design Concepts 56-020 Santa Fe Trail Ste. A Yucca Valley, CA 92284 (760) 365-8742 Report Prepared By: Gina Rose BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 9/12/2002 CITING A QUINTA BUILSAFETY DEPT. OVED FTRUCTIONiDATELBY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is r authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. _v This program developed by EnergySoft, LLC (415) 883-5900. . EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 1 i E 9 Certificate of Comaliance: Residential (Part 1 of 2) CF -1 R Building Horizons 9/12/2002 Project Title • Date 53-055 Avenida Herrera La Quinta Project Address - Building Permit # BREEZE AIR CONDITIONING (760) 346-0855. Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,665 fl? Total Conditioned Slab Area: 1,665 ft2 Average Ceiling Height: 8.9 ft Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Shadinq Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-30 Roof (R.30.2xl2.16) Wood 0.034 Exterior Roof R-19 Wall (W.19.2x6.16) Wood 0.065 Exterior Wall Solid Wood Door None 0.387 Exterior Door Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (North) 40.0 0.85 0.70 Bug Screen ❑ IRI ❑ x❑ Front (East) 20.0 0.87 0.70 Bug Screen ❑ X❑ ❑X❑ Front (East) 4.0 0.72 0.73 Bug Screen ❑ x❑ ❑ x❑ Left (South) 52.0 0.87 0.70 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 53.4 0.85 0.70 Bug Screen ❑ X❑ ❑X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 09112102 11:12:31 Run Code: 1031854351 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: I Pa e:3 of 25 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Building Horizons 9/12/2002 • Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type , Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 42 Setback HVAC -1 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal o� r Less Small Gas Recirc/Time+Temp 1 40 000 •50 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Design Concepts Address: 56-020 Santa Fe Trail Ste. A Yucca Valley, CA 92284 Telephone: (760) 365-8742 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: • Telephone: Documentation Author Name: Gina Rose Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 C Z p2. (signature) ( te) EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Paae:4 of 25 1 Certificate of Compliance: Residential (Addendum) CF -1 R Building Horizons 9/12/2002 _Project Title Date 0 Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 537 sgft Exposed Slab Floor, 3.50" thick at Entire Residence HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1128 sgft Covered Slab Floor, 3.50" thick at Entire Residence HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field veritication and diagnostic testing of these measures on a form GF -61R. plan Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 09/12/02 11:12:31 Run Code: 1031854351 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:5 of 25 • 41 • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate ofr Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(,): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturers labeled R -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does A'§ not apply to exterior mass walls). E]"§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. a§ 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑%� §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. rX §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:6 of 25 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit • documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not , be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. F§ 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X1 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures © §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number: Page:7 of 25 Computer Method Summary (Part 1 of 3) C -2R Buil- . Ponzons 19665 Floor Construction Type: 91,2/2_Q02 OP Tie 50.55A_venida�ierrera La�uinta Single Fam Detached DatqNe Project Address (East) 90 deg Total Fenestration Area: Building Permit # BREEZE AIR CS2N.DITIONING 1.00 (760) 346-0855 14,818 Documentation Author 1 Telephone Plan Check/Date B�.mputer .ance 15 1 Field Check/Date Compliance Method (Package or Computer) Floor Area Volume Climate Zone Type Hgt. Area Source Energy Use Standard Proposed Compliance —Setback_ n/a (kBtu/sf-yr) Design Design Margin Space Heating 3.55 2.72 0.82 Space Cooling 39.09 38.54 0.55 Domestic Hot Water 14.68 14.31 0.37 Totals 57.32 55.57 1.75 GENERAL INFORMATION FX-] Slab Floor Conditioned Floor Area: 19665 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Total Fenestration Area: 10.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 14,818 Number of Stories: 1 Slab Floor Area: 1,665 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 1,665 14 818 1 00_ C.nnditioned— —Setback_ n/a • 0 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Bong 1,665 903A_ /!/all— 389 ___0M5_ 0_ _91Z _W:;11_ _28.2 —0_0.6.5_ 9.0. 9.Q_ J?oor— 20 __D_a87_ 9k _90 .Door_ 18 ___0_3f9_ 90 ___ao_ (all_ 377 9 OFi5 180 9.0_ Wall —323. x.065 97,Q_ 90 Solar Gains Y / N Form 3 Reference :.. 1� 19D]kBilood Door ►� Solid W...Door Location / Comments ntir - Residence Entire -Residence Entire_ Residence Entire_ Residence -Enter . Residence Fntira RPsidenCe Fntire Residence EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 25 1 Computer Method Summary (Part 2 of 3) C -2R Building Horizons 9/12/2002 -Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments j— Windom R. -ht (Noah) 2 Window Front (East) 3 Window Front (East) 4 Window Left (South) 5 Window Left (South) 6 Window Left (South) L Window Left (South) 8 Window Rear (West) 180 90 Double Metal Clear Default Entire Residence 6.0 40-0 _0_85D_ n.70 n _99 Dputlle Metal{ tear Default_ -EntireBesjdeIIce 20.0 0.870 0.70 90 90 Double Metal Clear Default Entire Residence 4.0 0.720 0.73 90 90 Double Metal Clear Default Entire Residence 20.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 6.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 20.0 0.870 0.70 180 90 Double Metal Clear Default Entire Residence 6.0 0.870 0.70 180 90 Double Metal Clear Default . Entire Residence 53.4 0.850 0.70 270 90 Double Metal Clear Default Entire Residence INTERIOR AND EXTERIOR SHADING # Exterior Shade TvDe SHGC 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 I* — L_ EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:9 of 25 1 Computer Method Summary (Part 3 of 3) C -2R Building Horizons 9/12/2002 -Project Title Date NW THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight _5.37 _3-50 --28. 0_9.8. n/a 0 F_nkeBeside=.e-LSJab_on_Grade Concrete. Heavyweight 1.128 3_50 28 0_98 n/a 2 Entire Residence / Slab on Grade PERIMETER LOSSES • I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:10 of 25 1 F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 82 0.76 0.0 0 Entire Residence .Slab_P_etimelw 110 –116 —0 Q —0 Enti[eBesidence HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AF EE Ducts in Attic 4.2 Setback HVAC -1 •Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (°/a) Ext. Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. • I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:10 of 25 1 Computer Method Summary (Addendum) C -2R Building Horizons 9/12/2002 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies r1 L_J C )asea on the aaequacy of the special justitication ana aocumentation sunmittea. Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 537 sqft Exposed Slab Floor, 3.50" thick at Entire Residence HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1128 sqft Covered Slab Floor, 3.50" thick at Entire Residence HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field Verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft I User Number: 3665 Job Number: Paoe:11 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Building Horizons 9/12/2002 SYSTEM NAME FLOOR AREA HVAC -1 1,665 • LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK],COIL HTG. PEAK CFM Sensible LatentCFM Sensible 1,697 33,576 5,70 910 33,677 0 1,679 1,684 0 0 100 4,305 1,752 100 4,628 0 0 1,679 1,684 41,2 1 41673 LENNOXHS29-060/80UHG4/5X-100 47,228 4,422 82,000 Total Adjusted System Output 47,228 4,422 82,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.1 OF 105.3 OF 105.3 OF Supply Air Ducts Outside Air. 100 cfm 104.5 of Heating Coil Supply Fan 2000 cfm ROOMS 69.2 OF 70.0 of o,.a..... A:� n..,.a,. U49 I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0/78.4OF 76.8/63.0OF 54.8/53.6OF 54.8/53.6OF Supply Air Ducts Outside Air 100 cfm Cooling Coil Supply Fan 55.5 / 53.9 of 2000 cfm 50.2% R.H. ROOMS 74.8162.0 OF 74.0 / 61.7 OF EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:12 of 25 1 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:13 of 25 PROJECT NAME Building Horizons DATE 9/12/2002 SYSTEM NAME HVAC -1 FLOOR AREA 1,665 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Entire Residence Entire Residence 1 1,697 33,576 5,701 1,697 33,576 5,701 910 33,677 PAGE TOTAL 1,697 33,576 5,701 910 33,677 TOTAL 1 1,697 33,576 5,701 910 33,677 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:13 of 25 ROOM HEATING PEAK LOADS Project Title Date Buildinq Horizons 9/12/2002 Room Information Desi - n Conditions Room Name Entire Residence Time of Peak Jan 12 am Floor Area 1,665 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr L 2. Door 1,665.0 x X x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0341 X X x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = - = = = - = = = = = - = = = = 2,495 1,377.8 0.0655 44.0 3,968 93.4 0.8500 44.0 3,493 37.8 0.3872 44.0 644 72.0 0.8700 44.0 2,756 4.0 0.7200 44.0 127 perimeter = 192.0 44.5 8,544 nems snown wnn an astensK l 1 aenote conauction inrougn an imenor sunace to anotner room. Page Total: I 22,0271 Infiltration: I 1.00 1 x 1.072 x 1 665 x 8.90 x 60] x 0 = 11 650 chedule Air Sensible Area Ceiling Height ACH DT Fraction .Y HEAT LOSS FOR ROOM EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 14 of 25 —71 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Building Horizons 9/12/2002 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction -30 Roof R.30.2x12.16 R-19 Wall .19.2x6.16 Double Metal Clear Default Solid Wood Door Double Metal Clear Default Double Metal Clear Default Area U -Value Entire Residence 740F 116°F 42°F DETD1 X 59.0 X 38.6 X 42.0 X 38.6 X 42.0 X 42.0 X X X Btu/hr 3,345 3,481 3,334 565 2.631 121 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 13 477 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr C (North) (East) F (East) A (South) B (South) A (South) B (South) D (West) 1,138 ( 0.0 1 4.0 ( 0.0 X1 X X x X X x x X + + + + + + + + + 40.0 x X X X X X X X X 15 ) X ) x x x x X )X 0.779 = = = = = = = = = 468 ( 0.0 1 20.0 73 0.779 1,138 ( 0.0 1 4.0 73) 0.813 237 ( 0.0 1 20.0 32) 0.779 499 ( 0.0 1 6.0 32) 0.779 150 ( -0.0 1 20.0 32) 0.779 499 ( 0.0 1 6.0 32)X 0.779 150 ( 0.0 1 53.4 73)x 0.779 3,038 ( S h d Page Total 1 6,177 c e . Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,665 x 0.000 Wafts/sqft x 3.41 BtuhlWatt = 0 Occupants 1.00 X 1,665 X 250 Btuh/occ. / 250 sqft/occ. = 1,665 Receptacle 1.00 x 1,665 x 0.200 Watts/sqft X 3.413 BtuhlWaft = 1,137 Process 1.00 x 1,665 X 0.000 Watts/sqft X 3.41 Btuh/Waft = 0 Infiltration: �on� x Airs x x Ceiling Height X�x / 60]Area _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,5761 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 665 x 200 Btuh/occ. / 250 sgftlocc. = 1 332 Receptacle 1.00 x 1 665 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 1 665 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = Infiltration: 1 1.001 x 4 806 tent X Area 1 66 X Ceiling Height t X ACH 60] 0.00368 = 4 369 chedule Alr Lapyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,701 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 25 E 0 • VALUE 80TM 80UHG UP-FLOW/HORIZONTAL GAS FURNACES Bulletin No. 210215 ENGINEERING DATA *80.0 to 80.5% A F U E November 1997 45,000 to 120,000 Btuh (13.2 to 32.2 kW) Input Heating Capacity 1-1/2 thru 6 Tons (3.5 thru 21.1 kW) Nominal Add-on Cooling 'Isolated Combustion System Rating for Non -Weatherized Furnaces DESIGN Ar n:nrUia"cr P� 9Y CEHfIFEO GAS lama 9s �o� FOCI AA\ CERTIFIED UP -FLOW POSITION Typical Applications Up -Flow Utility Room Installation With Cooling Coil and Automatic Humidifier FEATURES Applications 080UHG series gas fired furnaces include ten models (natural gas or LPG/propane) with input capacities of 45,000, 60,000, 75,000, 100,000 and 120,000 Btuh (13.2, 17.6, 22.0, 29.3 and 32.2 kW) •A.F,U.E. up to 80.5%. • Up -flow or horizontal applications. •Lennox add-on evaporator coils, electronic air cleaners and power humidifiers can be easily added to the furnace. •Units are shipped factory assembled with all controls installed and wired. *Each unit is factory test operated to insure proper operation. Tubular Aluminized Steel Heat Exchanger •Constructed of aluminized steel for superior resistance to corrosion and oxidation. *Curving design allows com- plete exposure of heating sur- faces to supply air stream. • Round surfaces create mini- mum air resistance and allow air to surround all surfaces for excellent heat transfer. •Compact design reduces space requirements in unit cabinet. *Heat exchanger has been laboratory life cycle tested. HORIZONTAL POSITION Horizontal Attic Installation With Cooling Coil, Electronic Air Cleaner . and Automatic Humidifier Approvals *Units are certified by A.G.A./C.G.A. Laboratories *Ratings are certified by LAMA. *Units have been rated and tested according to U.S. DOE test procedures and FTC labeling regulations. •80UHG "X" models meet California Nitrogen Oxides (NOX) Standards and California Seasonal Efficiency requirements. *Blower data is from unit tests conducted in the Lennox Labo- ratory air test chamber. *Units are approved for conventional or horizontal (sidewall) venting. NOTE - Horizontal venting requires sidewall power venting kit, see Optional Accessories. Equipment Warranty • Heat exchanger - limited warranty for ten years. *Solid-state ignition module - limited warranty for three years. *All other components - limited warranty for one year. • Refer to the Lennox Equipment Limited Warranty certificate included with the equipment for details. Induced Draft Blower *Induced draft blower prepurges heat exchanger and safely vents flue products. *Blower is controlled by the fumace control center board for a prepurge cycle (15 seconds) and a post purge cycle (5 seconds). *Pressure switch proves blower operation before allowing gas valve to open. *Induced draft blower operates only during heating cycle. @1997 Lennox Industries Inc. NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. 49 SPECIFICATIONS Model No. 80UHG2(X)-45 80UHG2(X)-60 80UHG3(X)-60 80UHG2(X)-75 80UHG3(X)-75 80UHG4(X}75 Input Btuh (kW) 45,000 (13.2) 60,000 (17.6) 75,000 (22.0) Output Btuh (kW) 36,900 (10.8) 49,200 (14.4) 61,700 (18.1) ..A. F.U.E. 80.1% 80.5% 80.1% 80.0% California Seasonal Efficiency 75.4% 76.4% 75.9% 76.8% 76.8% 76.3% Flue size connection diameter - in. (mm) round 3 (76) 4 (102) Temperature rise range - IF (°C) 30 - 60 (17 - 33) 45 - 75 (25 - 42) High static certified by A.G.AJC.G.A. - in wg. (Pa) .50(125) Gas Piping Size I.P.S. Natural or LPG/propane 1/2(13) Blower wheel nominal diameter x width in. 9 x 7 10 x 7 9 x 7 10 x 7 12 x 8 mm 229 x 178 254 x 178 229 x 178 254 x 178 305 x 203 Blower motor output - hp (W) 1/4(187) 1/3(224) 1/4(187) 1/3(224) 1/2(373) Nominal cooling that can be added Tons 1, 1-1/2 or 2 2, 2-1/2 or 3 1, 1-1/2 or 2 2, 2-1/2 or 3 2,2-1/2,3, 3-1/2 or 4 kW 3.5, 5.3 or 7.0 7.0, 8.8 or 10.6 3.5, 5.3 or7.0 7.0, 8.8 or 10.6 7.0, 8.8, 10.6, 12.3 or 14.1 Shipping weight - Ibs. (kg) 1 package 130 (59) 135 (61) 140 (64) Electrical characteristics 120 volts - 60 hertz - 1 phase (less than 12 amps) All models Optional Accessories. (Must Be Ordered Extra). LPG/propane kit LB -69845L (38K84) Twinning Kit 96,169 - 5 lbs. (2 kg) Up-Flow/Horizontal Filter and Filter Rack Kits ©No. & size of filters - in. (mm) Single (32,102) Ten Pack (66K64) (1) 16 x 20 x 1 (406 x 508 x 25) Sidewall Power Venting Kit 79,115 - 25 lbs. (11 kg) Hanging Bracket Kit LB -69957 (46J66) - 15 lbs. (8' kg) MAnnuai ruei utilization ttnciency based on u.5. Uut test procedures and according to r i u labeling regulations. isoiateo combustion system rating for non-weamenzea tumaces. ®Polyurethane frame type filter is fumished with kit. Model No. Input Btuh (kW) Output Btuh (kW) t❑A.F.U.E. California Seasonal Efficiency Flue size connection diameter - in. (mm) round Temperature rise range - IF (°C) High static certified by A.G.AJC.G.A. - in wg. (Pa) Gas Piping Size I.P.S. Natural or LPG/propane Blower wheel nominal in. diameter x width mm Blower motor output - hp (W) Nominal cooling Tons that can be added kW Shipping weight - lbs. (kg) 1 package Electricai characteristics Twinning Kit Up-Flow/Horizontal Filter and Filter Rack Kits MNo. & size of filters - in. (mm) Sidewall Power Venting Kit Hanging Bracket Kit i T+Annual Fuel Utilization Efficiency based on U.S. DOE test MPolyurethane frame type filter is furnished with kit. 80UHG3/4(X)-100 \1 80UHG4/5(X)-100 ] 80UHG3/4-120 I 80UHG4/5() 100,000 (29.3) 120,000 (35.2) 82,000 (24.0) 98,400 (28.8) 80.1% 80.00/6 80.1% 76.5% 77.0% Not Available 75.5% 4 (102) 45 - 75 (25 - 42) 35 - 65 (19 - 36) 45 - 75 (25 - 42) .50(125) .65(162) .50(125) 1/2(13) 12x8 12x9 12x8 12x9 305 x 203 305 x 229 305 x 203 305 x 229 1/2(373) 3/4(560) 1/2(373) 3/4 (560) 2, 2 1/2, 3, 3-1/2 or 4 3-1/2, 4, 5 or 6 2, 2-1/2, 3, 3-1/2 or 4 3-1/2, 4, 5 or 6 7.0, 8.8, 10.6, 12.3 or 14.1 12.3, 14.1, 17.6 or 21.1 7.0, 8.8, 10.6, 12.3 or 14.1 12.3, 14.1, 17.6 or 21.1 175 (79) 120 volts - 60 hertz - 1 phase (less than 12 amps) All models Optional Accessories (Must'Be.Ordered Extra) LB -69845K (81,114) 96,169 - 5 lbs. (2 kg) Single (46,114) Ten Pack (66K65) (1).20 x 20 x 1 (508 x 508 x 25) 79.115 - 25 lbs. (11 kg) LB -69957 (46,166) - 15 lbs. (8 kg) to 80UHG / Page 3 ► INSTALLATION CLEARANCES - inches (mm) UP -FLOW POSITION Vent Type Type "B" Type "C" Sides 0 inches (0 mm) 0 inches (0 mm) Rear 0 inches (0 mm) 0 inches (0 mm) Top 1 inch (25 mm) 1 inch (25 mm) Front 2 inches (51 mm) 2 inches (25 mm) 'rront (service) 24 inches (610 mm) 24 inches (610 mm) Floor Combustible Combustible Flue 1 inch (25 mm) 6 inch (152 mm) NOTE -Air for combustion and supply air ventilation must conform to the methods outlined in American National Standard (ANSI -Z223.1) National Fuel Gas Code or National Standard of Canada CAN/CGA-149.1, & CAN/CGA-149.2 `Installation Code for Gas Burning Appliances". NOTE -In the U.S. flue. sizing must conform to the methods outlined in current GAMA/A.G.A. venting tables, American National Standard (ANSI -7223.1) National Fuel Gas Code or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CGA-149.1 and .2. HORIZONTAL POSITION Vent Type Type "B" Type "C" ides .:,].2 inches (51 mm) i i2 inches 51 mm) Rear 0 inches (0 mm) 0 inches (0 mm) 1!Top .%0 inches (0 mm) i.0 inches (0 mm) Front 2 inches (25 mm) 2 inches (25 mm) Front (service) 24 inches (610 mm) 24 inches (610 mm) Floor 0 inches (0 mm) 0 inches (0 mm) Flue 1 inch (25 mm) 6 inch (152 mm) NOTE -Air for combustion and supply air ventilation must conform to the methods outlined in American National Standard (ANSI -7223.1) National Fuel Gas Code or National Standard of Canada CAN/CGA-149.1, & CAN/CGA-149.2 'Installation Code for Gas Burning Appliances". NOTE -In the U.S. flue sizing must conform to the methods outlined in current GAMA/A.G.A. venting tables, American National Standard (ANSI -2223.1) National Fuel Gas Code or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CGA-149.1 and .2. Jline contact installation permissible between jacket top or sides and building joists. BLOWER DATA 80UHG2-45, 80UHG2-60 AND 80UHG2-75 BLOWER PERFORMANCE External Static Pressure High Air Volume at Various Blower Speeds Medium -High Medium -Low Low Low in. w.g. Pa cfm Us cfm Us cfm Us cfm Us 0 0 1270 600 980 460 770 365 570 270 .05 12 1245 590 975 460 770 365 565 265 .10 25 1220 575 975 460 770 365 565 265 .15 37 1195 565 965 455 765 360 560 265 .20 50 1170 550 960 455 760 360 560 265 .25 62 1140 540 950 450 760 360 555 260 .30 75 1110 525 940 445 760 360 550 260 .40 100 1060 500 910 430 750 355 545 255 .50 125 990 465 880 415 740 350 540 255 .60 150 900 425 810 380 690 325 530 250 .70 175 800 380 740 1 350 1 630 1 295 520 245 NO All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished) in place. Also see Filter Air Resistance table 8 3-60 AND 80UHG3-75 BLOWER PERFORMANCE External Static Pressure High Air Volume at Various Blower Speeds Medium -High Medium -Low Low in. w.g. Pa cfm Us cfm Us cfm Us cfm Us 0 0 1425 670 1240 585 1000 470 800 380 .05 12 1415 670 1230 580 995 470 800 380 .10 25 1400 660 1220 575 990 465 795 375 .15 37 1385 655 1200 565 985 465 795 375 .20 50 1370 1 645 1180 555 980 460 790 375 .25 62 1350 635 1160 545 970 460 780 370 .30 75 1330 630 1140 540 955 450 770 365 .40 100 1280 605 1095 515 925 435 750 355 .50 125 1210 570 1040 490 900 425 720 340 .60 150 1135 535 985 465 861 405 680 320 .70 175 1070 505 920 435 800 380 630 300 NOTE - All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished) in place. Also see Filter Air Resistance table 80UHG4-75, 80UHG3/4-100 AND 80UHG3/4-120 BLOWER PERFORMANCE External Static Pressure High Air Volume at Various Blower Speeds Medium -High Medium Medium -Low Low in. w.g. Pa cfm Us cfm Us cfm Us cfm Us cfm Us 0 0 1830 865 1600 755 1325 625 1070 505 880 415 .05 12 1815 855 1585 750 1320 625 1070 505 880 415 .10 25 1800 850 1570 740 1315 620 1070 505 880 415 .15 37 1875 885 1550 730 1310 620 1065 505 875 415 .20 50 1 1750 1 825 1530 720 1300 615 1060 500 875 415 .25 62 1725 815 1515 715 1290 610 1050 495 870 410 .30 75 1700 800 1500 710 1275 600 1040 490 870 410 AIII1h40 100 1650 780 1460 690 1245 590 1020 480 860 405 50 1 125 1600 755 1 1420 670 1210 570 1000 470 840 395 .60 150 1550 730 1 1380 650 1170 1 550 980 460 820 385 .70 175 1480 1 700 1 330 630 1130 1 535 960 455 1 790 375 NOTE - All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished) in place. Also see Filter Air Resistance table 0UHG / Page 4 j► DIMENSIONS - inches (mm) E • • GAS PIPING 2 (51) ELECTRICAL INLETS INLET (Top & Bottom)1 (25) Ei0 D olff '19 1/2 (495) '19 FLUE 4-1/4. n` i (483) OUTLET -111111110 (105) n C SUPPLY vuuu U AIR .DODO 0000 _OPENING *NOTE- Supply air opening at rear and sides of cabinet is 1 equipped with a 3/4 inch (19 mm) scored flange that may (25) be bent out 90' for plenum connection. Dimensions shown are after flange is bent out. Double scored flange at front of supply air opening may TOP VIEW be bent out for a total opening dimension (front to rear) of either 19-1/2 inches (495 mm) or 19 inches (483 mm). No A 29-5/8 (752) 2 (51) AIRFLOW —111110. "NOTE- Return air opening is equipped Return Air with a 3/4 inch (19 mm) flange 1 .•C 1 that may be bent out 90° for (25) Opening (25) plenum connection. Dimensions FRONT VIEW shown are after flange is bent out, 1 (25) 1 (25) 1 (25) 3/4 (19) "19-1/2 Return Air 1 (495) Opening (25) SIDE VIEW Model No. A B C D E F F Left Side 80UHG2-45 G Right Side GAS PIPING'-•..; INLET. in. 17 36-1/4 (Both Sides)..- ides)..- 6-3/4 2-7/16 6-1/2 12 80UHG2-75 0.0 O 0--.r', ELECTRICAL LJ: �.�. INLETS (Either Side) 11971/2 (495): 15 RETURN AIR 80UHG3-75 mm (381) KNOCKOUT; 921 381 (Either Side)'.` 62 114 254 80UHG4-75 r� r 1- "NOTE- Return air opening is equipped Return Air with a 3/4 inch (19 mm) flange 1 .•C 1 that may be bent out 90° for (25) Opening (25) plenum connection. Dimensions FRONT VIEW shown are after flange is bent out, 1 (25) 1 (25) 1 (25) 3/4 (19) "19-1/2 Return Air 1 (495) Opening (25) SIDE VIEW Model No. A B C D E F G 80UHG2-45 80UHG2-60 in. 17 36-1/4 15 6-3/4 2-7/16 6-1/2 12 80UHG2-75 80UHG3-60 80UHG3-75 mm 432 921 381 171 62 114 254 80UHG4-75 80UHG3/4-100 in. 20-1/2 39 18-1/2 8-3/8 4-1/4 8 131/2 80UHG3/4-120. 80UHG4/5-100_' 80UHG4/5-120 mm521 991 470 213 108 203 343 80UHG / Page 6 ► Technical Publications CONDENSING HS29 • ;ENGINEERING DATA ELITE 11 Tm SERIES SEER - 10.0 to 12.05 Cooling Capacity - 12 000 to 62 500 Btuh (3.5 to 18.3 M E CEFMFIC:AT'CN APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI VERIFIED Bulletin No. 210304 ENERGY September 2000 PERFORMANCE Supersedes July 2000 Typical Application C S LISTED S LISTED MODEL1 1 HS29 - 036 -1 Y Unit Type J Voltage HS = High Side Condensing Unit P = 2081230v-1 phase-60hz Series Y = 20a1230v-3 phase-60hz G = 460v-3 phase-60hz Cooling Capacity Tons (kW) J = 575v-3 phase-60hz 012 = 1 (3.5) Minor Revision Number 018 = 1.5 (5.3) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 042 = 3.5 (12.3) 048=4(14.1) 060 = 5 (17.6) FEATU RES Applications SEER up to 12.05. 1 through 5+ ton (3.5 through 17.6+ kW) matches with TXV or RFC. Single and three phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching blower powered or add-on furnace evaporator units provide a wide range of cooling capacities and applications. See ARI Ratings table. For evaporator unit data, see Coils - Blower Coil Units, this section. - Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. Installer must set condensing unit, connect refrigerant lines and make electrical connections to complete job. Approvals Certified in accordance with the USE certification program, which is based on ARI Standard 210/240-94. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270-95. Tested in the Lennox Research Laboratory environmental test room. Rated according to US Department of Energy (DOE) test procedures and approved rating methods. Condensing units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are UL and ULC listed. Energy rating verified by CSA. - Developed in accordance with ISO 9000 quality standards. Equipment Warranty Compressor — Ten years (residential applications), five year (non-residential applications). All other covered components — five years (residential), one year (non-residential applications). Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2000 Lennox Industries Inc. RFCIV METERING SYSTEM Refrigerant Flow Control ORIFICE BODY RFCIV Units applicable to expansion valve systems or RFC systems when matched with (On Coil) "BULLET' specific evaporator coils. ORIFICE RFCIV: Accurately meters refrigerant in system. ° LIQUID Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. 0-RING LINE The principle involves matching evaporator coil with proper bore size of orifice in metering device.O LIQUID Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating LINE SCREEN need for additional controls. r gam, SEAL Furnished with condensing unit. II I]. II NUT SWEAT 1��L�►I CONNECTION Unit Cabinet - Heavy gauge steel cabinet with five station metal wash process. - Powder paint finish provides superior rust and corrosion protection. - Painted base section. - Control box is conveniently located with all controls factory wired. - Corner patch plate allows access to compressor. - Drainage holes are provided in base section for moisture removal. Reciprocating Compressor (HS29-012 thru -024 Models and Three Phase Models) - Designed for dependable efficiency with minimum operating cost. - Suction cooled and overload protected with internal pressure relief. - Hermetically sealed with built-in protection from excessive current and temperatures. - Crankcase heater assures proper compressor lubrication (three phase models only). - Running gear assembly resiliently suspended internally inside case. Compressor installed in unit on resilient rubber mounts assuring low sound and vibration free operation. - HS29-012 model equipped with rotary compressor. CopelandO Compliant Scroll Compressor (HS29-030 thru -060 models) Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.'> As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. - When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. - During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and ^; maximizes efficiency. - Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. - Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. PVC coated steel wire coil guard furnished as standard. Condenser Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Rain shield on motor provides additional protection from moisture. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. g SPECIFICATIONS Model No. Model No. HS29-012 HS29-018 I HS29-024 HS29-030 HS29-036 Nominal Tonnage (kW) 1 (3.5) 1.5 (5.3) 2(7.0) 2.5 (8.8) 3(10.5) iquid line - in. (mm) o.d. connection (sweat) t3/8 (9.5) t3/8 (9.5) t3/8 (9.5) t3/8 (9.5) 3/8(9.5) uction line - in. (mm) o.d. connection (sweat) 5/8(15.9) 5/8(15.9) 5/8(15.9) 3/4(19.1) *Refrigerant charge furnished (HCFC -22) 2 lbs. 12 oz. (1.25 kg) 3 lbs. 10 oz. (1.64 kg) 3 lbs. 13 oz. 4 lbs. 4 oz. (1.73 kg) (1.93 kg) 4 lbs. 9 oz. (2.07 kg) Condenser Net face area - sq. ft. (m2) Outer Coil 7.56 (0.70) 11.33 (1.05) 13.22 (1.23) 15.11 (1.40) --- Inner Coil ---- Coil Coil Tube diameter - in. (mm) & no. of rows 18 (748) 5/16 (7.9) - 1 Diameter - in. (mm) & no. of blades Fins per inch (m) 18(457)-4 22 (866) 18 (748) 22 (866) 1/6(124) Diameter - in. (mm) & no. of blades 18(457)-3 18(457)-4 2610 (1232) Motor hp (W) 2930 (1383) 3010 (1420) 1/6(124) Condenser Fan Cfm (Us) 1125 2400 (1135) 2545 (1200) 2520 (1193) Rpm 200 1105 310 1110 310 Watts 208/230v -1 ph 180 195 200 Electrical Characteristics - 60hz 208/230v, 460v & 575v-3ph Shipping weight - lbs. (kg) 1 package 208/230v-1 ph 158 (72) 208/230v -3ph 460v-3ph Shipping weight - lbs. (kg) 1 package 107 (49) 1 140 (64) 143 (65) 140 (64) 148 (67) 145 (66) OPTIONAL ACCESSORIES= MUST,BE ORDERED EXTRA:.:. Low Ambient Control Kit - Expansion valve systems only Low Ambient Control Kit - Expansion valve systems only Crankcase Heater LB-57113BC (24H77) 90P12 - = - - I 9OP12 - - Crankcase Heater imed-Off Control 68887 9OP12 - - - - Timed -Off Control nit Stand Off Kit LB -507096K (47J27) Unit Stand Off Kit M132 -S (69J06) 94J45 Hail Guards Mounting Base 17L73 MB2-S (69J06) Hail Guards 17L71 I 17L72 17L73 Compressor Monitor (Optional for Canada Only) T6-1469 (45F08) Start Kit - See ARI Rating tables for specific usage 10J39 I 19K40 66K91 I 1 OJ42 - - - refrigerant charge sufficient for 20 ft. (6.0 m) length of refrigerant lines. 8 x 5/16 in. (9.5 x 7.9 mm) adaptor furnished for liquid line connection. SPECIFICATIONS Model No. HS29-042 HS29-048 ? HS29-060 ; HS29-062 Nominal Tonnage (kW) 3.5 (12.3) 4(14.0) 5(17.5) 5+(17.5+) Liquid line - in. (mm) o.d. connection (sweat) 3/8(9.5) Suction line - in. (mm) o.d. connection (sweat) 7/8(22.2) 1-1/8 (28.6) *Refrigerant charge furnished (HCFC 22) 5 lbs. 10 oz. (2.55 kg) 6 lbs. 3 oz. (2.81 kg) 6 lbs. 1 oz. (2.75 kg) 8 lbs. 3 oz. (3.71 kg) 7 lbs. 10 oz. (3.46 kg) 8 lbs. 3 oz. (3.71 kg) Condenser Net face area sq. ft. (m2) Outer coil 15.11 (1.40) 21.11 (1.96) Inner coil 5.40 (0.50) 14.40 (1.34) 20.3(l.89) Coil Tube diameter - in. (mm) & no. of rows 5/16 (7.9) - 1.37 5/16 (7.9) - 2 Fins per inch (m) 18 (748) 22 (866) Diameter - in. (mm) & no. of blades 18(457)-4 Motor hp (W) 1/6(124) , 1/3(249) Condenser Fan Cfm (Us) 2610 (1232) 3115 (1470) 2930 (1383) 3010 (1420) 2930 (1385) Rpm 1105 1125 1100 1125 1100 Wafts 200 325 310 315 310 Electrical Characteristics - 60hz 208/230v -1 ph 208/230v & 460v-3ph 208/230v -1 ph 208/230v, 460v & 575v-3ph 208/230v-1 ph 208/230v, 460v & 575v-3ph Shipping weight - lbs. (kg) 1 package 161 (73) 158 (72) 1 194 (88) 191 (87) 212 (96) 207 (94) 254 (115) OPTIONAL ACCESSORIES- MUST BE ORDERED EXTRA Low Ambient Control Kit - Expansion valve systems only LB-57113BC (24H77) Crankcase Heater 90P12 - - - 90P12 - = - - I 9OP12 - - imed-Off Control LB-50709BK (47,127) nit Stand Off Kit 94J45 Mounting Base M132 -S (69J06) Hail Guards 17L73 Compressor Monitor (Optional for Canada Only) T6-1469 (45F08) 'Refrigerant charge sufficient for 20 ft. (6.0 m) length of refrigerant lines. HS29 / Page 4 ► -meter to Naaonai or Canadian tiectrncai Code manual to aetermine wire, ruse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. INLET AIR i I 4 INLET AIR INLET L� AIR TOP VIEW 24-1/4 (616) (4,3/8 443/8 ) ( ) OPTIONAL UNIT J:1 ET STAND-OFF KIT (4) OMPRESSO)R (Field Installed) / D COIL DRAIN OUTLETS \ / R (Around perimeter of base) . F 6-3/8 SUCTION LINE CONNECTION (162) o LIQUID LINE -3/8 4318 CONNECTION 6 6-3/8 (111) TOP VIEW BASE SECTION 24-114 (616) CONDENSER DISCHARGE* AIR COIL FAN \ .�w� vier (1y) COMPRESSOR [ SUCTION & I' LIQUID LINE CONNECTION ELECTRICAL \ INLETS 2-3/4 (70) 51) OPTIONAL UNIT SIDE VIEW STAND-OFF KIT (4) (Field Installed) Model No. ELECTRICAL DATA 1PHASE A B HS29-012, HS29-018 HS29-024 in. 25 24-1/4 mm 635 616 HS29-030 in. 29 28-1/4 Model No. , HS29-012 I HS29-018 HS29-024 HS29-030 HS29-036 HS29-042 HS29-048 HS29-060 mm 838 Line voltage data - 60 hz 208/230v 1 p j� Rec. maximum fuse or circuit breaker size (amps) 15 20 30 35 1 40 45 60 "Minimum circuit ampacity 7.3 11.0 13.7 19.5 21.1 26.5 25.9 37.9 Rated load amps 4.9 1 7.9 10.1 14.7 16.0 20.3 19.2 28.8 Compressor Power factor .97 .96 .90 .91 .84 .98 .95 Locked rotor amps 26.3 T 48.3 60.0 84.0 100.0 127.0 137.0 169.0 Condenser Coil I Full load amps 1.1 1.9 Fan Motor Locked rotor ams 1.9 4.1 3 PHASE Model No. HS29-036 1 HS29-042 HS29-048 HS29-060 HS29-062 Line voltage data - 60 hz - 3 phase 208/230v 460v 208/230v 460v 208/230v 460v 575v 208/230v 460v 575v 208/230v 460v Rec. maximum fuse or circuit breaker size (amps) 20 10 25 15 30 15 10 40 20 1 15 40 20 'Minimum circuit ampacity 14.0 6.9 16.6 8.6 18.8 10.2 . 8.2 23.5 12.2 9.8 23.5 12.2 Rated load amps 10.3 5.1 12.4 6.4 13.5 7.4 5.8 17.3 9.0 1 7.1 17.3 9 Compressor Power factor .83 .93 .88 .86 Locked rotor amps 77.0 39.0 88.0 1 44.0 91.0 149.0 40.0 128.0 64.0 50.0 137 62 Condenser Coil Full load amps 1.1 0.55 1.1 0.55 1.9 0.9 0.9 1.9 0.9 0.9 1.9 0.9 Fan Motor Locked rotor ams 1.9 1.0 1 1.9 1.0 4.1 2.1 2.1 1 4.1 1 2.1 2.1 4.1 2.1 -meter to Naaonai or Canadian tiectrncai Code manual to aetermine wire, ruse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. INLET AIR i I 4 INLET AIR INLET L� AIR TOP VIEW 24-1/4 (616) (4,3/8 443/8 ) ( ) OPTIONAL UNIT J:1 ET STAND-OFF KIT (4) OMPRESSO)R (Field Installed) / D COIL DRAIN OUTLETS \ / R (Around perimeter of base) . F 6-3/8 SUCTION LINE CONNECTION (162) o LIQUID LINE -3/8 4318 CONNECTION 6 6-3/8 (111) TOP VIEW BASE SECTION 24-114 (616) CONDENSER DISCHARGE* AIR COIL FAN \ .�w� vier (1y) COMPRESSOR [ SUCTION & I' LIQUID LINE CONNECTION ELECTRICAL \ INLETS 2-3/4 (70) 51) OPTIONAL UNIT SIDE VIEW STAND-OFF KIT (4) (Field Installed) Model No. A B HS29-012, HS29-018 HS29-024 in. 25 24-1/4 mm 635 616 HS29-030 in. 29 28-1/4 mm 737 718 HS29-036, HS29;042- HS29-048, HS29-060,.HS29-062 in. 33 32-1/4 mm 838 819 43/8 (111) 43/8 (111) HS29 / Page 5 ► i L REFRIGERANT LINE KITS Condensin Length of Unit 9 Line Set Lines Model No. Model No. ft. m Liquid Line Outside Dia. Suction Line Outside Dia. in. mm in. mm HS29-012 HS29-018 HS29-024 L15-21-20 20 6 5/16 7.9 5/8 15.9 L15-21-25 25 8 L15 21-35 35 11 L15-21-50 50 15 HS29-030 L15-31-20 20 6 5/16 7.9 3/4 19 L15-31-30 30 9 L15-31-40 40 12 L15-31-50 50 15 HS29-036 L15-41-20 20 6 3/8 9.5 3/4 19 0 9 0 12 50 15 ML15-65-3030 HS29-048.50 0 9HS29-042 3/8 9.5 7/8 22.2 0 12 15 HS29-060_ HS29-062 Field Fabricate 3/8 9.5 1-1/8 28.5 * One of the coil sides adjacent to control box must be 30 in. (762 mm) for service. One of the remaining sides may be 12 in. (914 mm) One of the remaining sides may be 6 inches (305 mm) NOTE - 48 in. (1219 mm) clearance required on top of unit. NOTE - 24 in. (610 mm) required between two units Unit Size & Model No. ®Sound Rating Number OO ARI Standard 210/240 Ratings Up -Flow Down -Flow Cooling Cap. 10.20 EER Total Unit Watts Btuh kWSEER Evaporator Coils 1730 12,200 3.6 10.05 9.95 1225 - - - - C33-18AC23-21 --- ---- 11.75 12,500 12,500 3.7 11.00 10.05 1245 *C26-21 ---- ---12,700 1730 12,700 3.7 11.00 10.15 1250 OC26-26 - - - - C33-30A/B - - - - 10.75 12,300 3.6 11.00 9.90 1245 CR26-21 1 Ton HS29-012 (74 db)- 12,000 3.5 10.00 9.70 1235 _-__ - - 1phase 12,500 3.7 10.30 10.10 1235 ---- - - 12,800 1 3.8 10.50 10.15 1260 13,200 1 3.9 11.05 10.25 1290 1.5 Ton HS29-018 (76 db) 1 phase 18,000 1 5.3 1 10.20 10.20 1 1765 19,000 5.6 11.55 11.00 1730 19,000 5.6 11.50 10.95 1735 19,400 5.7 11.75 11.15 1740 19,000 5.6 11.50 11.00 1730 18,000 5.3 11.20 10.45 1720 18,700 5.5 10.75 10.20 1830 CB29M-21/26 (Multi -Position) OCB30M-21/26 (Multi -Position) 1/26 ---- Horizontal *'Expansion Valve Kit Required LB -85663L (26K49) C23-21 LB -85663L (26K49) - - - - - - - - *Factory Installed •Factory Installed - - - - - - - - LB -85663L (26K49) LB -85663L (26K49) #C26-26 #C26-26 CH3318A-F CH218A CH23-31 133-36-A/B/C-F LB -85663L (26K49) Valve - - - - - - - - CH33-30A-F *Factory Installed - - - - - - - - CH33-36A/B/C-F C33 -18A - - - - - LB -85663L (26K49) C23-21 OC26-21 - - - - - - - - *Factory Installed C23-26 - - - - - - - - LB -85663L (26K49) --- ;33-30A/B - - - - ---- #C26-26 #C26-26 - - - - - •Factory Installed ---- CR26-21 ---- LB -85663L (26K49) ---- ---- CH23-21 - - - - - - - - CH33-30A-F ---- ---- CH23-31 - - - - - - - - CH33-36A/B/C-F 191000 5.6 11.50 11.00 11725 C829M-21/26 (Multi -Position) 19,600 5.7 12.00 11.15 1755 OCB30M-21/26 (Multi -Position) *Factory Installed t/CB30U-21/26 - - - - Ask 18,900 5.5 11.50 10.90 1730 1 91CVP10-26/EC10Q3 - - - - - - -Ratings for C23, C26 and C33 coils include all cased and uncased coils. Wertified on accordance with the USE certification program, which is based on ARI Standard 210/240; 95°F (35°C) outdoor air temperature, 80°F (27°C) db / 67'F (19°C) wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. ®Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. ®Canada Only "Kit is required and must be ordered extra, unless shown as factory installed. • Furnished as standard with coil. ♦ Start kit is required for for proper system operation. Must be ordered extra. See specification table. HS29 / Page 6 ► Unit Size & NOTE--- EJARI Standard 210/240 Ratings Model No.Coolin Ca g p. Total Up-Flow Down-Flow Horizontal "Expansion Valve Kit L22 Sound Rating SEER EER Unit Required Number Btuh I kW Watts Evaporator Coils 44,000 112.9 10.80 9.60 4585 C26-41 - - - - I- - - - •Factory Installed C33-44C - - - - - - - - LB-85663K (26K35) 45,000 13.2 10.85 9.75 4615 C26-46 - - - - - - - *Factory Installed C33-48B/C - - - - - - 46,500 13.6 10.75 9.55 4870 C23-51 - - - - - - - - LB-85663K (26K35) C33-50C - - 46,500 13.6 11.00 9.80 4745 *Factory Installed C26-51/65 - - - - - - - - C23-51/65 ---- ---- 47,000 13.8 10.80 9.70 4845 C33-60D - - - - - - - - LB-85663K (26K35) C33-62D - - - - - - - - 48,000 14.1 11.05 10.00 4800 C26-65EAP - - - - - - - - *Factory Installed 45,000 13.2 10.65 9.50 4735 - - - - CR26-51 ---- ---46,000 46,000 13.5 11.00 1 9.80 4695 - CR26-65 ---- ---46,000 - - - - CH33-4413-F 46,000 13.5 10.85 9.65 4770 - - - - CH23-51 LB-85663K - - - - - - - - - - - CH33-SOC-F (26K35) 4 Ton 46,500 13.6 11.00 9.75 4770 _ CH23-65 HS29-048 _ _ _ _ _ CH33-62D-F (80 db) 48,000 14.1 11.00 10.00 4800 _ ---- kW SEER EER Watts Blower Coil Units Valve CB30M41 (Multi-Position) 44,000 12.9 10.75 9.55 4605 CB30U41/46 I ---- I ---- 44,000 12.9 10.85 9.70 4535 C831MV-41 (Multi-Position) 45,500 13.3 10.50 9.35 4865 CB29M-46 (Multi-Position) 45,500 13.3 10.60 9.40 4840 C829M-51 (Multi-Position) 45,500 13.3 11.00 9.80 4645 CB30M-46 (Multi-Position) 46,000 13.5 10.55 9.40 4895 CB29M-65 (Multi-Position) CB30M-51 (Multi-Position) •Factory Installed 46,500 13.6 11.05 9.90 4700 C830U-51 I ---- ---- 46,500 13.6 11.25 10.10 4605 CB31MV-51 (Multi-Position) CB30M-65 (Multi-Position) 47,000 13.8 11.05 9.90 4750 CB30U-65 - - -- I ---- 47,000 13.8 11.35 10.25 4585 C831MV-65 (Multi-Position) 44,000 12.9 10.00 9.15 4810 ®CVP10-51/EC10Q4 - - - - - - 44,000 12.9 10.00 9.15 4810 2CVP10-65/EC10Q5 -- - Btuh kW SEER EER Watts Evaporator Coils Valve - - - - - - - - U3-85663K (26K35) 55,500 16.3 10.50 8.90 6235C33-50C C26-51/65 - - - - - - - - •Factory Installed 58,000 17.0 10.50 9.20 6305 C23-51/65 - - - - C33-60D - - - - - - - - LB-85663K (26K35) C33-652D C33-62D - - - - - - - - 61,000 17.9 - 11.00 -- - - 9.35 --- 6525 - - - - - - - - eFactory Installed 52,500 15.4 10.00 8.55 6140 - - - - CR26-51 --- ---- 54,500 54,500 16.0 10.50 8.85 6160 - - - - CR26-65N Only ---- ---57,000 57,000 16.7 10.50 9.00 6335 - - - - CR26-65W Only ---- ---56,000 56,000 16.4 10.00 8.55 6550 - - - - - - - - CH33-50C-F CH23-51 LB 85663K (26K35) 5 Ton - - - - - - - - HS29-060 , 57,000 16.7 10.50 9.00 6335 - - - - - - - CH33-60D-F '(80 db) - - - - _ CH23-65 1 phase 61,000 17.9 11.00 9.35 6525 - - - - - - - CH33-62D-F CH23-68 Btuh kW SEER EER Watts Blower Coil Units Valve 54,500 16.0 10.05 8.65 6300 C829M-51 (Multi-Position) 55,500 16.3 10.05 8.50 6530 CB29M-65 (Multi-Position), 55,500 16.3 10.50 8.90 6235. CB30M-51 (Multi-Position) C630U-51 I ---- I ---- 55,500 16.3 11.00 9.55 5810 C831 MV-51 (Multi-Position) *Factory Installed 58,000 17.0 11.00 9.35 6205 CB30M-65 (Multi-Position) CB30U-65 58,000 17.0 11.00 9.35 6205 CB31MV-65 (Multi-Position) 53,000 15.5 10.00 8.50 1 6235 2CVP10-51/EC10Q4 --- - - 54,500 16.0 10.00 1 8.50 1 6410 1 p4 CVP10-65/EC10Q5 I - - - - ---- NOTE - Ratings for C23, C26 and C33 coils include all cased and uncased coils. Q Certified on accordance with the USE certification program, which is based on ARI Standard 210/240; 95°F (35°C) outdoor air temperature, 80°F (27°C) db / 67°F (19°C) wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. ®Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. ®Canada Only "Kit is required and must be ordered extra, unless shown as factory installed. • Furnished as standard with coil. HS29 / Page 9 ► LLsL��'C�;" L21 SERIES 24 HOUR THERMOSTATS For Conventional Heating/Cooling Systems Only (Non -Heat Pump Systems) THERMOSTATS Bulletin #210125 November 1996 Supersedes #480059 September 1993 • 1_21'SERIES 7 DAY THERMOSTATS For Conventional Heating/Cooling Systems Only (Non -Heat Pump Systems) Model No. • Description Catalog No. Model No. Description Catalog No. L211201 CS ......... 1 Heat/1Cool 24 Hour ........ 69H25 L211407CS .......... 1 Heat/1Cool 7 -Day ......... 75H19 L212201CS ......... 1 Heat/2 Cool 24 Hour ........ 69H26 L212407CS .......... 1 Heat/2 Cool 7 -Day ......... 75H2O A2000 -ROS ..... Outdoor Temperature Sensor .... 69H27 A2000 -ROS ..... Outdoor Temperature Sensor .... 69H27 *Automatic Or Manual Changeover *Built-in Time Delays • Large Easy -to -read LCD Readout •Actual Time And Temperature in 'F or °C for alternating inside and outside temperature readout (with optional outdoor temperature sensor) •Two Stage Coolinrg Model features low or high speed cooling operation indicators *Check Filter Indicator flashes at preset interval •System Selector Switch (Off -Heat -Cool -Auto) •Fan Switch (On -Auto) *Indicator Lights ("Amber" light indicates system operating, "Green" light indicates night period energy savings) *Solid-state Electronic Technology eliminates battery back-up and maintains thermostat settings during power failure for up to 24 hours •Two Separate (Day & Night) time and temperature settings per day *Individual Slide Switches set day and night heat and cool temperatures and nighttime beginning and ending time periods • "Cancel Night" button overrides night temperature settings •"+" and "-" buttons set time of day *Pressing front cover reviews thermostat settings Optional Outdoor Temperature Sensor A2000 -ROS With optional sensor, thermostat will give a readout of present out- door temperature and lowest and highest outdoor temperatures of the day and times at which they occurred. See next page. *Full Independent Seven-day Programming *Automatic Or Manual Changeover *-Built-in Time Delays *Large Easy -to -read LCD Readout *Actual Time And Temperature in °F or 'C for alternating inside and outside temperature readout (with optional outdoor temperature sensor) •Two Stage Cooling Model features low or high speed cooling operation indicator •Check Filter Indicator flashes at preset interval *System Selector Switch (Off -Heat -Cool -Auto) • Fan Switch (On -Auto) . *Indicator Lights show !'Amber" indicating system is operating in manual mode or (flashing) 3 hour override, "Green" light indicates system demand *Solid-state Electronic Technology eliminates battery back-up and maintains thermostat settings during power failure for up to 24 hours •Four Separate Time And Temperature Settings Per Day *Individual Slide Switches set time begin and heat and cool temperatures • "+" and "-" buttons set time of day • "Day" button sets day of week and reviews daily programs • "Review" button displays programmed time period setpoints • "Manual" button allows manual control of temperature • "Clear" button erases programmed setpoints when re -programming • "Enter" button enters time of day and temperature setpoints into memoty • Monitors compressor run times and heating times in hours and cycles • Pressing front cover reviews thermostat settings Optional Outdoor Temperature Sensor A2000 -ROS With optional sensor, thermostat will give a readout of present out- door temperature and lowest and highest outdoor temperatures of the day and times at which they occurred See next page. NOTE — Specifications, Ratings and Dimensions subject to change without notice. .4:1996 Lennox Industries Inc. ,