BSOL2014-0032
04 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: SOLARCITY'CORPORATION 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 TiG�„'Y 4Q" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2014-0032 Carrier: _ Polity Number: _ 53055 AVENIDA HERRERA I certify that in the performance of the work for which this permit is issued, I 774053014 shall not employ any person in any manner so as to become subject to the workers' 3.6kW PV SYSTEM - (14) 255W PANELS/(1) INVERTER $7,889.00 \ j workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions. OCT 30 20" A� ^ „-y OF LA OVINTA ' Date: Applicant: /' ( J 412 z" u116t DaaCIDL^w^ff DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0108752 Date: Contractor: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/30/2014 Owner: BRAULIO GUDINO 53055 AVENIDA HERRERA LA QUINTA, CA 92253 Contractor: SOLARCITY CORPORATION 000TSIDE CITY LIMITS LA QUINTA, CA 92253 (650)638-1030 Llc. No.: :LIC -0108752 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: _ Polity Number: _ I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions. Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3---)4 A� ^ of the Business and Professions Code) or that he or she is exempt therefrom and the ' Date: Applicant: /' ( J basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ($500).: , AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ( ) I, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. 1 Each person upon whose behalf this application is made, each person at whose ( ) I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application , the owner, and the applicant, each agrees to, and State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors' State License Law.). following issuance of this permit. (_) I am exempt under Sec. , B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: I certify that I have read this application and state that the above information is correct. . I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned roperty for inspection purposes. Date: Signature (Applicant or Agen TINANCIALINFORmAT.ioN 's DESCRIPTION y ACCOUNT ? zH QTY ti � PAID PAID DATE a >AMOUNT � ,,>y „.F. ,,; y, sm,.:i..,� dV"-i,�an..1,.Pow .ro-k' "`',.,_;'x8a .� ,.�.>S-ata, •.u.3R;.,b.. �wi: ,<`,y �. r..„Jh�,"4. ao�`.%€ :. <<:'. ,>.. .'a.:.s�+fh: A?. ... ,.>w'i_ ..-f.n .. r3"la BSAS SB1473 FEE 101-0000-20306, 0 $1.00: $0.00 7*tAY PAID BY METHODF _ ,t -. k 4 p ! rt RECEIPTS#F CHECK # CLTD BY , a _ rt '. Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 . aiXF .4fiR:'`l°,T DESCRIPTION r� Fd. wS F-#: ACCOUNT f .meq, r£'. fr :�Y ...:.• AMOUNT <.,r€ } d PAID PAID:DATE k ,F.s.3x{..., s .. a -<FY_. n. -., ...,•'�v�-f .-. ...? ?_ 4;�,,.-;,,y_ ._ �, ', _ �'k7 .-$i,:�,. r;t�[l. 4� 7<-.P. 3e.`s..i'>?.:h"fk .,._,,',?: �.Zr a!- F_.:' PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 yip, it#x§ >i ,'zy. 'h? S' 'a"'�:i°1 �-a:'.",=N,`q. r` # S' sem` 4 bx{2. ,„,�"XY.,.:.;�ra-.e� _ � � _ i : F.A �'.F ' CHECW# • ;:% CLTD"BY, „ =PAID BYE Y y ai ::>:"i i=t Y METHUDk �„ �. S.Pv!- r ,?^s. x_.:,. . .� i J.. 3 .:� RECEIPT# F 4 >.r.: '`fib .-. .' E 6=>�--a�F•flG . tit. .. "I 'n.':^'Ji`'"'-' <, $ :t A�.J�'"�-. d PAID DATE' ,DESCRIPT IONyF:y<%ACCOUNT� 4TYAMOUNT . w�PAID �p PV SYSTEM =ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 h.`r PAIf)BY$ _RECEIPT r , r ,:r'`tsMETHOD,q Total Paid.forELECTRICAL: $48.34 $0.00 ? Fn; i�"74'..E F�. s 1as";V,� N;,. ,y7,`• -y�Y{j '�,u'�2 �<'j,,:1>.'•C�` ;Y�..3 aMNaT� >`PAID#K�. ; DESCRIPTION'^ I�,rr, zz�z .PAIDDATEN F PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Z C ( €, •E; i dx L R .. �" dL:. Sf S PAIDaS 4 X X3�?hC I j( -,;u 'S`r _w{ S>S«5 `'� "5 F` '�.a Jh t;sREC�EIPT #�..3 i�q _ S. #, ... _ CCTOtBY MyETH00 v ,CHECK Total Paid for PERMIT -ISSUANCE: $9]'.85 $0:00 • $0.00 Description: 3.6kW PV SYSTEM - (14) 255W PANELS/(1) INVERTER ADDITIONAL Type: SOLAR Subtype: Status: APPROVED Applied: 10/29/2014 JFU Approved: 10/29/2014 JFU Parcel No: 774053014 Site Address: 53055 AVENIDA HERRERA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 218 Lot: 2 Issued: UNIT 21 _ 10/29/2014 10/29/2014 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $7,889.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 3.6kW SOLAR ARRAY - (14) 255W KYOCERA PANELS W/ (1) ABB# PVI-3.0OUTD-S-US-Z-A INVERTER [2525F] 2013 CALIFORNIA ELECTRICAL CODE. ADDRESSI Printed: Thursday, October 30, 2014 12:03:32 PM 1 of 2 ` SYSTf:MS ADDITIONAL CHRONOLOGY TYPE STAFF NAME CHRONOLOGY ACTION DATE COMPLETION DATE NOTES E-MAIL JAKE FUSON 10/29/2014 10/29/2014 EMAILED MELISSA WITH SOLARCITY TO NOTIFY PERMIT READY TO ISSUE. CONDITIONS NAME TYPE NAME ADDRESSI CONTACTS CITY STATE- ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 ( Printed: Thursday, October 30, 2014 12:03:32 PM 1 of 2 ` SYSTf:MS DESCRIPTION ACCOUNT i QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 . Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES SOLAR FINAL" PARENT PROJECTS Printed: Thursday, October 30, 201412:03:32 PM 2 of 2 �E7EY Symms Bin # 111 Ly (1I La (4u nta -Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico . La Quints, CA 92253 - (760) 777-7012. Building Permit Application and Tracking-Sheet Permit # Project Address: Owner's Name A. P. Number: 14 USMI 1 Address:5305S yl )C' Legal Description: City, ST, Zip:01_ayl�,CA 3 ' Contractor, ,Clkd Telephone: — Address:3 Project Description: City, ST, Zip: KA +e-6 2 Ci Telephone: g? %fs<%:h{v>.`��'�''�s�:? State Lic. #: City Lie. #; Arch., Engr.; Designer: Address: City., ST, Zip: Telephone: • ' State Lic. #: 14'y','�� h•Yf.;t:Gn•f{' 4'i.•l,.%+ ':Y,Ui:�il: 'f.?•f. •tom Y^ ', ;: v(f,;��;� � t �.,.:L..t;�,�; Y w, u..... v../ k:. i.Y' `:h ?o ; n � ..... Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: �JeI SSa Sq. Ft.: # Stories: # Units: Telephone #•of Contact Person: _ Estimated Value of Project: APPLICANT: DO NOT WHITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets PIan Check submitted n Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance • Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionsrssue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up - S.M.Y. H.O.A. Approval Plans resubmitted Grading IN IiOUSE:- 3"Review, ready for correctio (issue l Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees . l 9 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES M1 A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS ,OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER GC kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR - kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC C'-� 0°STA LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). - ,. I +� DEPT. MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN BUILDING c. (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY APP�— NEUT NEUTRAL UL LISTING. FOR COs`:: i Ru 10 NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING DATE BY P01 POINT OF INTERCONNECTION HARDWARE. v PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX iu Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS IAGRAM LICENSE GENERAL NOTES PV6 ELECTRICAL 1HREE LINE CALCULATIONS CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 Cutsheets Attached C-10 CALIFORNIA BUILDING CODE AND THE 2013 Q CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH Y O THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. t MODULE GROUNDING METHOD: ZEP SOLAR ? ' REV BY DATE COMMENTS AHJ: La QUIntO REVA NAME DATE COMMENTS UTILITY: Imperial Irrigation District ��� ��yy Y k Y CONFIDENTIAL - THE INFORMATION HEREIN JDB NUMBERJB-9222113 00 PREMISE O*a DESCRIPTION: DEEM O CONTAINED SHALL NOT BE USED FOR THE GADINO, BRAULIO GADINO RESIDENCE Kevin Grath '\`�'' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTile 53055 AVENIDA HERRERA 3.57 KW PV ARRAY '���SolarCit • PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA ORGANIZA710N, EXCEPT CEPT IN CONNECTION WITH CA 92253 THE SALE AND USE OF THE RESPECTIVE (14) KYOCERA # KD255GX—LFB3 3055 p`8W W0Y L& SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN APN: 774053014-3 PAGE NAME: SHEET: REk DAT- Sa, Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' T:(650) 638-1028 R(650) 638-1029 ABB PVI-3.0—OUTD—S—US—Z—A ( COVER SHEET PV 1 9/26/2014 (BBB)-sot.—QTY (265-2489) www.eolorcity.com W JI� & WARNING LABELS © LnI ® I WI I DC JUNCTION/COMBINER. BOX &LABELS Q DISTRIBUTION PANEL &LABELS Lc LOAD CENTER &WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS TRANSFORMER INFORMATION: --- KVA PHASE HIGH KV _ LOW 120/240V �� '� -METER#1 B4SR-134442 L =�J PROPOSED BI-DIRECTIONAL ° 'METER SITE PLAN N jfl---------- CUTLEWMMER #DG221URB - AC DONNECT: r! 2FT FRMAIN PANEL - INVEfb: ABB PVI-3.O1j!j:OUTD-S-US-Z-A W & WARNING LABELS © LnI ® I WI I CONFIDENTIAL — THE INFORMATION HEREIN J0B NUMBER. JB -9222113 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �^ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTlle PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGTHE SALE AND USES OF ITHE�RESPECTnnvEWTM (14) KYOCERA # KD255GX-LFB3 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB# PVI-3.0—OUTD—S—US—Z—A aw OF LA QUINTTA BUILDING & SAFEW APPROVED FOR CONSTRUCTION DATE BY—&� Front Of House -�� - - 3' FSB--®----� Iw I(n IW I ® I 3' FSB --_ B P113 I MP1C I U- 0 i 1 - AC IMPM B STRUCTURE CHANGE 200A, 240V, SINGLE PHASE, 2 WIRES,' 22kAiC EXISTING BI DIRECTIONAL METER#164SR-134442 GADINO, BRAULIO 53055 AVENIDA HERRERA LA QUINTA, CA 92253 ( GADINO RESIDENCE 3.57 KW PV ARRAY PAGE NAME SITE PLAN (E) DRIVEWAY PITCH: 18 ARRAY PITCH: 18 MPl AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 Si LEGEND a O (E) UTILITY METER & WARNING LABEL I�� INVERTER W/ INTEGRATED DC DISCO a c a� Q Ln LO 0 l� Scale: 1/8" = 1' W E 0 1' 8' 16' S DESIGN: Kevin Groth I,`�OIarCit y 3055 Clearview Way SHEET: REV: DATE Son Mateo, CA 94402 P V 2 9 2014 26 T: (650) 638-1028 F:(650) 638-1029 / / (888)—SOL—CITY (765-2489) www.adarcity.com & WARNING LABELS © DC DISCONNECT &WARNING LABELS AC DISCONNECT &WARNING LABELS DC JUNCTION/COMBINER. BOX &LABELS Q DISTRIBUTION PANEL &LABELS Lc LOAD CENTER &WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED �� '� INTERIOR EQUIPMENT IS DASHED L =�J SITE PLAN N 3055 Clearview Way SHEET: REV: DATE Son Mateo, CA 94402 P V 2 9 2014 26 T: (650) 638-1028 F:(650) 638-1029 / / (888)—SOL—CITY (765-2489) www.adarcity.com SIDE VIEW OF MP1B NTS A MP1B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER I NOTES LANDSCAPE 48" 24" PREMISE OWNER DESCPoPTION: GADINO, BRAULIO GADINO RESIDENCE � 53055 AVENIDA HERRERA 3.57 KW PV ARRAY LA QUINTA CA 92253 r PAGE NAIL ( STRUCTURAL VIEWS DESII Kevin Groth \� N,„!, � •;,� i��SolarCity MOUNTING SYSTEM - ZEP ZS Tile WTile MODULES (14) KYOCERA # KD255GX-LFB3 3055 CI�ew Woy s®, Mateo ca 94402 L(650) 638-1028 F(650) 638-1029 (888) -SOL -CITY (765-2489) wwwoorcity.. SHEET: REN DATE PV 3 9/26/2014. ABB PVI-3.o—ouTD—s—US—z—A UPLIFT CALCULATIONS ' 09 26.2014 r"'S�i�afCl4 S�eekMountT'"' PV System (/erslonA.30A '' StruleturalDesnn Softn►are Project Information &`Table 0f Corttents Ris�egory'' DESIM Kevin Groth dI ZEP ZS Tile WileIN MOUNTING SYSTEM: PVSSysteM m Type MODULES: (14) KYOCERA # KD255GX7LFB3 Solaii9ly;51eeliMounttp1_ MEET: REV: DATE PV 4 9/26/2014 Span l f SpanistfTile Roof La ers of;Cam :Raofih' Roof.Slope 18° PV System Module'Orientabon. L'andsope.and Portrait' PV _otluleA Pv ModuleWidth. 39" pV MDdule Standoff AttachmentHardiaare . SM Tile ReducO Ground/Roof Llve/.Snout/ Loads° Ground'Snow Load. ` _pg: 0.0 psf Sround Snowy _ OA psf ASCE"Table 7-4 /ISEEq :7:4' "�1 Roof Snow (vee Pv. Module's?. 0.004 ASCE.Eq:. 7.+4 Wind.Qesi `n:'Crit A; WindDeslgn Code, .� _..._..��...r Metho_ d .� ASCE 7-10 Partially/Fully Enclosed Method Basic Wind Speed :V 110 -mph Fig: Z6'S aA p use �fegdry"� � `.0 Setlo 26 Roof Style Gable Roof' R9.'ao t2Na/c sNe M>` ea Roof Heiylit§ �1Nft- on Z6 2 Effective'Wind Area'. 1 Module . A 17.7 sf- 4BC'15093.1: :Wlnd�Pressure. Calculation :Coefficients Wind Pressure. Exposure Ki 0.85 Table- 303=1: Topogfil ora Kits 1.00Sedion;26:8 Wind Dim onlity Facto Kd 0.85' ';16h 26"s6 1" Ir ortance'Factorr Is. NA' Velocity Pie&mre qh; 4h _ 0:00356 k.4(U- ) (Kd) vi^2) Equation 30,3 1. Ext: Pressure Coeffiaent (lJp) Ext; f?iessure.CoeftioentDown`!'-' Up). GC (Down ' -0 88� 0 95 . ft; .30:4-*B/C-5AIB AB O 4�2A/B1c sA%s Design Wind Pressure +p =' h (GCpj E iiaticn-30.4=1 Wind`Pressure 00 {i(u'p) -19.6 ps_fT Wind Pressure Down.-__ - down . 16.0 Allowablo5tarido."ffS.,. ci`:jo >X=Difectiion =Y "Din"ecEitin WU A116W_We Stiandoff Spadn'g Landscape 48" %39"' Maie�Allowable Cantilever. Landsr�pe :24"q, Standoff Confi uiabon; Land$ca a Not=Staggered Max StandoffT.11 L ryArea�_ Tiib' - - --- 13 sf PV Assembly Dead Load W-Pv 3 p#-,- Net Wind Upliftat°Standoff' ___"T actu 1 130 lbs. Uplift Capacity of`Standoff T allow. 4464bs' StandoffDeman Ca a ' D(R. 29c29/o= Max.AIW,6ble Standoff Spacing Portrait' Max AllowableCantilever_ StandWConfi u ation1 Portiart 19"-----. 1 A- Portrait _ Not= Staggered. Max,StandoffTributary Area: _Trip.;. 22 50 PV A Sse� mbly Dead Load Net Wlnd�Uplift�4t�Standoff 1.101KCapaoty of ` -Standoff: �T_adual;� T-,allow >-219'Ibs: 446 Itis': Standoff.:Deman Ca .D.CR', 49:09ti. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR SHALL IBENEFIT OF TNBENDI CLOSED IN WHR E EXCEPT SOLATY ORC PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF soIARCITY INC. JOB NUMBER:JB-9222113 O O PREMISE OWNER. DMPTIOK- GADINO, BRAULIO GADINO RESIDENCE 53055 AVENIDA HERRERA 3.57 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME: ( UPLIFT CALCULATIONS DESIM Kevin Groth \\` /IoASOlarCity ZEP ZS Tile WileIN MOUNTING SYSTEM: 1 MODULES: (14) KYOCERA # KD255GX7LFB3 3055 Cleardew.Way CA 94402 T:(650) Son Mateo, ) 638-1029 (BBB)-soL-aTY ('765-2469) www.solarcity.com MEET: REV: DATE PV 4 9/26/2014 iVERTER.. ABB PVI-3.0-0UTD—S-US—Z—A GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) UFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 — (1) ABB PVI-3.0—OUTD—S—US—Z—A LABEL: A — (14) KYOCERA # KD255GX—LFB3 CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number:184SR-134442 FCI nverter; Zigbee 3000W, 240V, 96% PV Module; 255W, 228.3W PTC, 40MM, Black Frame, ZEP Enabled- C-10 INV 2 Underground Service Entrance Voc: 37,6 Vpmax: 30.4 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A CENTER—FED MAIN SERVICE PANEL SolarCity E 125A/2P MAIN CIRCUIT BREAKER Inverter 1 IND CUTLER—HAMMER 125A/2P Disconnect 5 ABB 4 A > Vstart =DEFAULT DC+ - PVI-3.0—OUTD—S—US—Z—A M11x (E)LOADS — ------------------ 2gov E � — — _ —----- �7— Ll 11 L2 DC+ I 2OA/2Pr JAI N DC I EGG DC+ -GEC 3 2 VStart = DEFAULT DC- - oc Dc MP 1: 1x7 tpj ✓ B ------ =�,� - - - - - - - - - - EGC - - - - - - - - - - -- I v (1 )Conduit Kit; 3/4' EMT N GEC I C I i OF LA Q U I NTA TO 120/240V T SINGLE PHASE &SAFETY DEPT. UTILITY SERVICE I BUILDING APPROVED ' FOR CONSTRUCTION — DATE BY PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, - TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE Voc* =MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS PDI (1)SQUARE D fl HQMT2020z20 PV�ACKF E BREAKER Breaker, A 1P -20A 2P -20A 1P, 2 aces, Quad Tandem g (I CUTLER -HAMMER 8 DG221URB /� Disconnect; 30A, 240Voc, Non -Fusible, NEMA 3R „ A 0 )SolarCityy 4 STRING JUNCTION BOX D� 2x2 S1RGS, UNFUSED, GROUNDED -0) CUrTLERd-�tAMMdER I t 30ANGeneral Duty (DG) � 1 AWG #10, THWN-2, Block O I4N (1 )AWG #10, THWN-2, Red (1)AWG /8, THWN-2, Black Voc* = 296.36VDC O 4 (1)AWG i8, THWN-2, Red Vmp = 212.8 VDC Isc = 9.09 ADC Imp= 8.39 ADC 2 AWG g10, PV WIRE, Block Voc* = 296.36VDC Isc = 9.09 ADC O (1) AWG g10. Solid Bare Copper EGC Vmp = 212.8 VDC Imp= 8.39 ADC (1)AWG g10, THWN-2, White - (1) AWG g8,. T}1WRJ-2,. Green . •EGC/GEC NEUTRAL VmP =240 VAC Imp 14.5 AAC .- (1) Conduit• Kit;. 3/4' .EMT _ . • . • , • . • . ... , ... (1 AWG /10, THWN-2,.Green EGC, , .. (1 AMG J8, THWN-2, Block Voc* = 296.36VDC Vmp 212.8 VDC .. Isc = 9.09 ADC Imp= 2 (2) AWG 110, PV WIRE Block Voc* = 296.36 VDC Isc = 9.09 ADC Vmp 212.8 VDC Imp= 8.39 ADC O (1)AWG 18, THWN-2, Red = 8.39 ADC O ( 1 ) AWG #10, Solid Bare Copper EGC = ........ (1)AWG #10, THWN-2,.Creen, EGC ............................... . ................................................................ CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE SOLARCITY ,�B NUMBER ' J B-922211 3 00 PREMISE OWNER. DESCRIPTION: GADINO, BRAULIO GADINO RESIDENCE DESIGN:. Kevin Groth �• '"i Solar ity MouNTING Til No SHALL ITBEDISCLOSED N WHOLE ORCIN ZEP ZS Tile WTile S 53055 AVENIDA HERRERA 3.57 KW PV ARRAY . PART TO OTHERS OUTSIDE THE RECIPIENT'S . LA QUINTA, CA 92253 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE . (14) KYOCERA # KD255GX—LFB3 PACE NAME 3055 Cleo -view Way San Mateo, CA 94402 SHEET: HEV; DATE INVERTER-. ABB PVI-3.0—OUTD—S—US—Z—A PERRMIS90NCITY EOFISOLARCITY INC. THE WRITTEN )THREE LINE DIAGRAM PV 5 9/26/2014 (1186>S0L-63&-1028 TY 765-2 89i���rcciitycom ELECTRICAL CALCULATIONS I Icont * 1.25 = (Amps) String and 2 Combined Strings OCP Size = 20 Conductor 3: AWG -10 THWN-2 (cont * 1.25 = (Amps) 18.12 Module Type: Module Count: (cont = (Amps): Icont = (Amps) 14.5 Start ampacity Kyocera KD255GX-LFB3 14 Temperature derate (%=F) 11.36 Conduit fill derate (%) 1 Derated ampacity 36.4 Branch Circuit Individual MPPT 18.12 Ampacity 35 - 1 strings per Branch A 1 - strings per Branch B 7 modules per series string 7 modules per series string String Branch A Branch B Conductor: Conductor: Conductor: Icont * 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 55 55 PV Wire Size: AWG 10 AWG_8 AWG 8 Icont = (Amps) 11.36 14.2 14.2 Start ampacity 40 55 55 a ;;��,, 1 J Temperature derate (%=F) 0.41 0.41 0.41 y CITY OF .� Conduit fill derate (%) Derated 1 0.8 0.8 BUILDING & �� �' DEP•T. ampacity 16.4 18.04 18.04 Icont * 1.25 = (Amps) 14.2 14.2 14.2 ci APP Ampacity 40 50 50 F.OR CONSTR`- - :-0N Inverter output i Inverter Type: Inverter Count: Total ABB PVI -3.0-S AFCI 1 Icorit = (Amps): 7!.\TE 14.5 Icont * 1.25 = (Amps) 18.12 OCP Size = 20 Conductor 3: AWG -10 THWN-2 (cont * 1.25 = (Amps) 18.12 30 deg C ampacity = 40 Icont = (Amps) 14.5 Start ampacity 40 Temperature derate (%=F) 0.91 Conduit fill derate (%) 1 Derated ampacity 36.4 (cont * 1.25 = (Amps) 18.12 Ampacity 35 CONTAINEDAL A THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. d06 NUMBER: JB -9222113 O O PREMISE OWNER: DESCRIPTION: GA D I N 0, B R A D LI 0 GADINO .RESIDENCE 53055 AVENIDA HERRERA 3.57 KW PV ARRAY LA QUINTA CA 92253 r PAGE NAME: ( ELECTRICAL CALCULATIONS DESIGN: Kevin Groth �N` `Qw4p • eA _: olar ty. MOUNTING SYSTEM: ZEP ZS' Tile WTile MODULES: (14) KYOCERA # 0255GX-LFB3 3055 gearview Way T:(650) 638-1026 F:(650�638-1029 (666) -so, -CITY (765-2489) wncsolarcity.com SHEET: REV: DATE: PV 6 9/26/2014 INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV). Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF LA QUANTA BUILDING& SAFETY DEPT. APPROVE® FOR CONSTRUCTION Y DATE —_----- B (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Cleaview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED 'S ORGANIZATION, IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS - SC CA Label St e -��' �., , � 11►; San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE I�'So1a���o (888)-SOL-CrY(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. The SolarCity SleekMount hardware solu- • Zep Solar hardware and UL 1703 listed Zep tion is optimized to achieve superior Compatible modules strength and aesthetics while minimizing • Interlock and ground devices in system UL listed roof disruption and labor. The elimination of to UL 2703 visible rail ends and mounting clamps, . Interlock and Ground Zep ETL listed to UL 1703 as combined with the addition of array trim all "Grounding and Bonding System" contribute to a more visually appealing ,., • w • _ = '_ r" • j No file cutting required system. SleekMount utilizes Zep Compat- ibleTM modules with strengthened frames • Ground Zep UL and ETL listed to UL 467 as that attach directly to Zep Solar standoffs, grounding device#� effectively eliminating the need.for rail and • Anodized components for corrosion resistance' reducing the number of standoffs required: ,. • . � � i . n _ . F 1. ' Components 0^ZS Tile Roof Attachment Kit R' • t. ? © ZS Tile Replacement Flashing "16I 2;" SolarCity o January 2014 © Leveling Foot Q Lag Screw O 5/16" Wood Lag Screw Installation Instructions 0 Drill pilot hole O2 Seal pilot hole ®3 Place roof attachment kit ® Install lag QInstall flashing to jurisdiction preferences (see standoff detail on plans) © Secure leveling foot to roof attachment kit using machine screw Q Place module HIGH EFFIGIENC-Y M0JICRYSTAL PHOTOVOLTAIC MODULE QGOMPAr��� EgKYOCERa �OMPP�� CUTTING EDGE TECHNOLOGY As a pioneer with over 39 years in the solar energy industry, Kyocera demonstrates leadership in the development of solar energy products. Kyocera's Kaizen Philosophy, commitment to continuous improvement, is shown by repeatedly achieving world record cell efficiencies. QUALITY BUILT IN • UV stabilized, aesthetically pleasing black anodized frame • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire to work with transformerless inverters • Quality locking plug-in connectors to provide safe and quick connections RELIABLE • Proven superior field performance • Tight power tolerance • First module manufacturer to pass rigorous long-term testing performed by TOV Rheinland QUALIFICATIONS AND CERTIFICATIONS UL Listing y6t QIGU.E173074 C UL US - NEC 2008 Compliant, UL 1703, ISO 9001, and ISO 14001 UL1703 Certified and Registered, UL Fire Safety Class C KD 200-60 F Series KD250GX-LFB3 KD 255GX-LFB3 SOLAR by K, 0@0* ELECTRICAL SPECIFICATIONS FA -KD 200.60 F Series MODULE CHARACTERISTICS Dimensions: 65.43inf38.98inf 1.57in length/width/height (1662mmi990mmf40mm) Weight: 47.4lbs (21.5kg) PACKAGING SPECIFICATIONS Modules per pallet: 20 Pallets per 53' container. 36 Pallet box dimensions: 66ini40ini43in 1engtIT1-dth/height (1675mmf1005mm/1055mm) Pallet box weight: 1060lbs (480kg) 1 1P_ 250 255 W V_ 29.8 30.4 V ImP 8.39 8.39 A V� 36.9 37.6 V i 9.09 9.09 A P.I.- +51-0 +5/-0 % �TnOcr 45 45 °C iP.. 180 184 a W Vm• 26.8 27.4 V i lm• 6.72 6.72 A IV. 33.7 34.4 V 7.36 7.36 A PTC 223.7 228.3 W 1P_ -0.46 -0.46 %J°C Vm• -0.52 -0.52 f %/°C i Im• 0.0065 0.0065 %/°C ' V,- -0.36 -0.36 %/°C li 1. 0.060 0.060 %/°C Operating i Temp -40 t0 +90 -40 t0 +90 °C 1Series Fuse Rating 15 A '!!!!Maximum DC system Voltage (UL) 600 V Hailstone Impact in (25mm) @ 51 mph (23m(s) • Subject to simulator measurement uncertainty of,/. 3%. KYOCERA reserves the right to modify these specifications without notice. NEC 2008 COMPLIANT 1& ® W-1116: Read the instmction manual in its entirety prior to Qhandling,irutaBing8operdt- UL1703LISTED v Bg Kyocera Solar modules. 062614 FA -KD 200.60 F Series MODULE CHARACTERISTICS Dimensions: 65.43inf38.98inf 1.57in length/width/height (1662mmi990mmf40mm) Weight: 47.4lbs (21.5kg) PACKAGING SPECIFICATIONS Modules per pallet: 20 Pallets per 53' container. 36 Pallet box dimensions: 66ini40ini43in 1engtIT1-dth/height (1675mmf1005mm/1055mm) Pallet box weight: 1060lbs (480kg) KYOCERA Solar, Inc. 800-22,3 9580 800-5232329 fax wLn�v.kyocerasolar:colll 0.16- (4m) 0.35-.().47- (9-12.I FRAME CROSS SECTION DIAGRAM a"- - A 1.18-(1Lv1 css•araa - LONG/S1URT SIDE STABILIZER BAR OUR VALUED PARTNER This family of single-phase string inverters complements the typical number of rooftop solar panels enabling home -owners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions. (For example: East and West) The dual input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0%( The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed to be a completely sealed unit able to withstand the harshest environmental conditions. Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity A 1111 for abetter world" FUNI ND Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTO N :)I I I J 6.89 [175] O U v 6.81 [173] 5.73 [145] 6.36 [162] 1 .34 [9] � I • T7' N ON O N ®n M O N O O O O O 1p O O OO ® ® ® CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT °f o OUANTITY 2 QUANTITY 4 n N • M .n N 3.75 .(951 O N 27 [6.8 DIA. a 2.46 62 3 MOUNTING HOLES N [ ] .88 [22] N B m ®.36 [111] m M 4.75 [121] m lO B 1 1.01 [26] 4—A TANGENTIAL KNOCKOUTS FOR —1 2, 3/4, 1 CONDUIT QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. .281 [5.5j DIA. 2. WIRE RANGE OF LUGS IS AS FOLLOWS KNOCKOUfi LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM ,g2 [46 .82 [46 QUANTITY 1 N NEUTRAL #4-#14 COPPER OR ALUMINUM u 6.10 [155] m n 4 1D A r "-� M 'o. ula ,onWARREN 9PE S/ /98 CUTLER—HAMMER B�T•N OH M U Prrr58uRCN Pa o - a 00 - R. PROHSK 8%19/98 ^K DIMENSION SHEET ,a — 30 AMP TYPE 3R GENERAL DUTY 95-1445.DWG oam lr�ma w1 557aDGCl t1-2 rc c a �c 4M''"°95-1445 i of 1 icv. �ie/oe 4 3 2 1 J _ Switching Devices Q , Safety Switches V OG32INRB 120/240 Vac General -Duty, Fusible, Single -Throw, continued Maximum Horsepower Ratings r0 NEMA1 NEMA 3R Ampere Fuse Type Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number n Cartridge Type— Three-Pole,Three-Wire (Three Blades, Fuses) -240 Vac ® bbb 30 ° 1060 ^ - - - - - 0 OO Three -Pole, Three -Wire (Three Blades) -240 Vac 400 If — — 50-125 — DG325FGKO0 OG325FRK0@ DG321UGO0 600 Hr — — 75-200 — DG326FGKO0 DG326FRKOO • "- • Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac -- - DG323URB 0 200 — 15 60 — b/ 30 H — 1-1/1-3 3-7-1/7 — OG32INGB DG32INRB DG325UGK0' p p p 60 H — 3-10 7-1/2-15 DG322NGB OG322NRB DG326URKO jaT� jTa� jaT� 100 H 7-1/2-15 1 15-30 = DG323NGB OG323NRB 0 Maximum hp ratings apply only when dual element time delay fuses are used. 200 H — 15 25-60 — OG324NGK DG324NRK , 400 FI — — 50-125 — OG325NGK OG325NRK -- _ 600 H' — — 75-200 — OG326NGK OG326NRK DG322URB 120/240 Vac General -Duty, Non -Fusible, Single -Throw 0 Drilled to accept field installed neutral kits. Maximum Horsepower Ratings NEMA1 NEMA311 Y— Ampere Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating 120V 240V 240V 250V Catalog Number Catalog Number Two -Pole, Two -Wire (Two Blades) -240 Vac I 30 2 3 — — o/ DG221UGB0 DG221URBID 1 60 3 10 — — OG222UGBr•r OG222URBr•r 100 — 15 — — DG223UGB(D DGZ23URB0 Inn — — — — m m Three -Pole, Three -Wire (Three Blades) -240 Vac - I 30 1 3 7-1/2 — DG321UGO0 DG321URB0 6000 3 I 15 30 — DG323UGB 0 DG323URB 0 200 — 15 60 — DG324UGK0 DG324URK0 - 400 — — 125 — DG325UGK0' OG325URK0 601 — — 200 — DG326UGK0 DG326URKO Notes 0 Maximum hp ratings apply only when dual element time delay fuses are used. j 0 Use four -wire catalog numbers below. 0 Solid neutral bars are not included. Order separately from table on Page 15. ' r^ WARNING! Switch is not approved (or service entrance unless a neutral kit is installed t°) Use three -wile catalog numbers below. 0 Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition. clear line shields are available as an accessory , on 200 --WGA general -duty switches. Catalog Numbers: 200A = 767/59-11.400A = 70-8063-8.600A = 70-8060. I Volume 2—Commercial Distribution CA08100003E—February2011 www.eaton.com 27 t: F; Powering BusinessWdddmide 31, 0t�i: T t2o _ -DG221 UR.B General. Dutyy:.Safe Switch- r �Intercu `tor de'se u idad aervici0 I'l aro _ -2= Pole Non -Fusible' '�`�` '�,,.� s®ries = ►� ?-Polos sin � fusibles- ` ; y [Series..6- c ni.�:,�.'� ' P. n .• t t rk 1 F MADE IN U.S.A.-t- Tyyppe 3R Rain 'root �, , NECHOENE.II.II.� , ;X0'2 , 'W MAY Tipo 3R a prueba.de Ute` ,7 _82113.12023_ 2 T i L IZ £ 1 10 11 —56,.,,, 3 " Z-1 p;)04L55 ]rvY MN nLdM 9E0 aAlw'N O tnl3ml OMO'S941-S6 , .1LnO 1V213N30 HE 3dKl. dM Of Aw � 03M� 9 O XAIN 3W 133HS NOISN31v10 66/yq/B VXSVH08d 'S m um ,enn awosa m N3VAYd H'J6116SILd 3B Ol ION 9 H—N31ino 66/61/9 NIS N38HVM 5N 10 3 tf m 0° [SSL] OL'9 w {Nf1N1VIf11V 210 83ddOO blQ-tl# 1V211f13NnNi �Tz B'l 9b] ZB' LL I kLliNvno Wf1NIWf11V 210 93dd00. bl/j-9# SOM OVOI ONV 3NI1 bb(IONOONN SMO110d SV SI S0f11 30 30N" 3NIM 'Z 'VIO lS'S] 19 Z' 'S13NOV218 NI NMOHS 3bV (S8313WI1'11101 NI) SNOISN3114I0 DI&ON 'L ' :31ON l ,uiiNvno vnON00 L 'b/f Z/L 803 SLnO>100NN 1VI1N30NV1 8 � ro w (ZZ] 8B' S310H ONIdNf1C VIO 8'9] b KUINV(lo Z vnON00 b/f 'z/,. 11110N00 210d SlnO>100NN T/11N30NV1 8w S1f10NOONN OR 01 a� ll] 9f'b ® i 0 e .961 SLT N W I 0 N W N OI O I ZepSolar ZS Comp'" I Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Zep Compatible- systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Ground Zep Down -roof v !� ZS Comp Cutaway Illustration Interlock (Key side shown( Zep Compatible module with Zep Groove Leveling Foot Document 800-1478-001 Rev A www.zepsolar.com PAGE: 1 of 5 020131EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134:45 PM ZepSolar• Interlock Interlock Zep Z Keyside uL osteo to uL zrus Tongue side Key Side Bonding ZS COMP I GROUNDING AND BONDING Cutting *tooth' Side view Interlock Module Key side in closed position Bonding locations Cutting "tooth' on Key side Forced interference during rotation of Interlock Zep causes teeth to cut through anodization on module frame, resulting in robust and UL • certified bonding path Tongue Side Bonding Tongue side in closed position • O 111 Forced interference between matin Cutting "teeth' g parts from module Bonding location on rock -in motion cuts into module frame, removing Tongue side anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsotar.com PAGE: 2 of 5 © 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 2013 4:45 PM ZepSOlar ZS COMP I GROUNDING AND BONDING Interlock, continued Part No. 850-1388 UL Listed to UL 2703 Bonding Path - Key and Tongue Module MM. Ml 9 The Interlock bonds modules on all 4 sides to create a hyper - bonded array where every module Is structurally and electrically bonded to the surrounding modules. Tongue side Bonding Path - Array o Interlock of �j Bonding path a a b. ro w I i M rA /✓ M M W Rho 1 Down -roof 1 Key side Document 800-1478-001 Rev A www.zepsotar.com PAGE: 3 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25.20134:45 PM ®_ Zep Solar Leveling Foot ZS COMP I GROUNDING AND BONDING Tongue side .0 -> Key side Spring clip Part No. 850-1397 The Leveling Foot top portion (the Rockit) has a stainless steel UL listed to UL 2703 spring clip that bonds to the adjacent module frame on both Key and Tongue sides. Leveling Foot -Bonding With Module Frame .O Down -roof Z O Key side inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side Bonding Path - North and South Modules Bonding location on Key side Leveling Foot a ® ® Bonding path � b �d b� Bonding location on Module rotation during drop-in creates forced Down -roof Tongue side interference between Zep Groove and spring clip, cutting Into module frame, removing anodization and resulting in robust and UL certified bonding path Document 80D-1478-001 Rev www.zepsatar.com PAGE: 4 of 5 © 2013/EN Zep Solar. Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25,20134:45 PM Ground Zep Installation t 2 O 4 ;, a �_ .. Insert Ground Zep into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees, so that setscrew Insert copper EGC into ground wire on array perimeter is pointing straight up. channel. Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground .. . . . ... . .... . Zep ' . . .... Equipment Ground Conductor Bonding path OGround Zep ' Equipment Ground Conductor Bonding path Down -roof Document 800.1478-001 Rev www.zepsolarcom .. ©2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. PAGE: 5 of 5 Date Last Exported: June 25.20134:45 PM SolarCity Standard Box 4J The SOIarCity Standard Box 4J is a • Manufactured to meet UL 1741 Standards. 4 -String unfused Junction Box. The box . Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. is highly configurable and adaptable using the (4) jumper blocks included in • Factory -Installed Cordgrip Enhances Installation Speed. each box. A factory installed cordgrip • Break-Thru Skinned -Over Glands on Cordgrip Provide enhances installer productivity. Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. =-SolarCity. o October 2013 Technical Data / Specifications O Voltage Rating [VDC] : 600V Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A �D Maximum Voltage [VDC]: 600V OE Wire Size Range [AWG]: #6 to #14 ®F Enclosure Rating: NEMA 4X ©G Operating Temperature Range [°C]: -40 to 50 ©H Typical Overall Dimensions [in]: 8"x6"x4"