BWFE2014-111178-495 CALI.E TAMPICO D 4v� � VOICE (760) 777-7125
LA QUINTA,TCALIFORNIA 92253 FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/17/2014
Application Number:
BWFE2014-1111
Owner:
Property Address:
53210 AVENIDA DIAZ
3 BOULDERS
APN:
774042011
45311 GOLF CENTER STE B
Application Description:
42 LF. 5'& 24 LF 4' GARDEN WALL
INDIO, CA 0
Property Zoning:
Application Valuation:
$1,800.00
Applicant:
Contractor:
3 BOULDERS
CORONEL ENTERPRISES
45311 GOLF CENTER STE
B
51105 AVENIDA VILLA 101
INDIO, CA 0
LA QUINTA, CA 92253
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.::LIC-000 4
Date: �L�—�-1—�i Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not, intended or offered for sale. If, however, the building or improvement is sold
within bne year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_)I, as owner of the property, am exclusively contracting with licensed contractors
to cohstruct the project. (Sec. 7044, Business and Professions Code: The Contractors'
StatE License Law does not apply to an owner of property who builds or improves -
ther@on, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(-J I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
(760)775-1230
Llc. No.: :LIC -0000254
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and ag a that, if I should become pubb)'ect to the
workers' compensation provisions ofSec i n 3700 of the L CodII forthwith
comply with those provisions.
Date: 1 u—\-1 - 1"A Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or.pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relati_W to building
construction, and hereby authorize representativesd� tt i city tenter on the bo
mentioned property for inspection purposes.
Date: -Signature (ApplicantorAgentt. �J v
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT CITY AMOUNT
PAID
PAID DATE
BSAS 681473 FEE
101-0000-20306 0
$1.00
$0.00
PAID BY
METHOD RECEIPT #
CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY •
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for FENCE OR FREESTANDING WALL- $108.77 $0.00
TOTALS:0• i 00
Permit Details PERMIT NUMBER
r City of La Quinta BWFE,,2014 `1111
Description: 42 LF. S'& 24 LF 4' GARDEN WALL
CONDITIONS
CONTACTS
Type: WALL/FENCE Subtype:
Status: APPROVED
Applied: 10/17/2014 KHE
Approved:
Parcel No: 774042011 Site Address: 53210 AVENIDA DIAZ,CA
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 177
Lot: 14
Issued:
UNIT 18
EMAIL
APPLICANT
Lot Sq Ft: 0 Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $1,800.00 Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0
No. Unites: 0
Details: 42 L.F. 5' GARDEN WALL & 24 L.F.' GARDEN WALL AT PROPANE TANK AND POOL EQUIPMENT, CITY STANDARD
CHRONOLOGY
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
3 BOULDERS
45311 GOLF CENTER
INDIO
CA
0
STE B
CONTRACTOR
CORONEL ENTERPRISES
51105 AVENIDA VILLA
LA QUINTA
CA
92253
101
OWNER
3 BOULDERS
45311 GOLF CENTER
INDIO
CA
0
STE B
Printed: Friday, October 17, 2014 9:04:29 AM 1 of 2 CRWsrsrEMS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
ATTAC H M E NTS
Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS
NOTES
SEQID
INSPECTION TYPE
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
I-
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
FINAL"
Total Paid forBUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
WALL/FENCE - FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
WALL/FENCE - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDING WALL, $108.77 $0.00
TOTALS:0• 00
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
ATTAC H M E NTS
Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS
NOTES
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
INSPECTIONS
COMPLETED
DATE
RESULT
REMARKS
FOOTINGS
BOND BEAM
FINAL"
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
ATTAC H M E NTS
Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS
e ac
O
W
, Z
O
G
Z
Q
ALUMINUM SPIRAL SIAIRS
INSIALLED BY
MANUFACTURERS SPECS.
h DIE Ilrorr SfIL)r rdr_)IE.)
I
a
N
O
Y
W m
U z_
O
p o � 3
w C? C,
a
C ti a
Q
W
- o
Z
• 3
APN.:774-042-023
PROPOSED 6' Block Wall [By separate Permit]
SWALE MINIMUM (1) ONE %
APN.:774-042-011
.:::::...........:.::::..
0
0
w
(1) 24" BOX f _.... _...........�, ,,.... � PI QINT
SHOESTRING ACACIA PERMIT AND INSPECTION BY CITY OF LA
(ACACIA STENOPHYLLA) QUINTA PUBLIC WORMS
THE DEVELOPER/CONTRACTOR/OWNER
j IS RESPONSABILE FOR THE VERIFICATION OF
EXISTING CURB (OR EDGE OF STREET
U
N
`,I
e a�
Lu
F
Z
O
(`
CC
L
_Z
w
3
N
Lu
Z
O
2
�
a
Q
i
_z
W
0Z
CN
O W
N Q
3�
O W
10
D'a7
Z
Z
a
n+
al
O. _
Q
X
-- _
�
o
.:::::...........:.::::..
0
0
w
(1) 24" BOX f _.... _...........�, ,,.... � PI QINT
SHOESTRING ACACIA PERMIT AND INSPECTION BY CITY OF LA
(ACACIA STENOPHYLLA) QUINTA PUBLIC WORMS
THE DEVELOPER/CONTRACTOR/OWNER
j IS RESPONSABILE FOR THE VERIFICATION OF
EXISTING CURB (OR EDGE OF STREET
BLO*�94:
C.
ANGELUS BLOCK MASONRY FENCE WALL SYSTEM
IESIGN CRITERIA:
DESIGN CRITERIA PER 2013 CBC
:. ALLOWABLE SOIL BEARING PRESSURE = 1500psf
i. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf
COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf
i. CANTILEVER ACTIVE = 30pcf
i. MASONRY COMPRESSIVE STRENGTH, f'm = 1500psi. SPECIAL INSPECTION
NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY.
USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE
PROJECT SPECIFIC SITE.
TOTES:
REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615
GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24
INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS.
!. JOINT REINFORCEMENT ("LADDER- TYPE) SHALL BE COLD -DRAWN STEEL
WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES.
S. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS
OTHERWISE REQUIRED BY SOILS REPORT.
I. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS
BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR
WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR
ANGELUS BLOCK SLUMPSTONE SHALL BE USED.
S. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS
MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND
REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS
MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY
REQUIREMENTS OF ASTM C270.
i. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP,
AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF
GOpsi. Z, O 00 PS lr
1. . IRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE
IS PLASTIC.
3. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH
VERTICAL CONTINUITY OF THE CELLS.
). VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF
40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR
MORTAR WASHED
). GROUT ALL CELLS WITH REINFORCEMENT.
I. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL
FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL
REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT.
>-. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS
6' to 8' H
Trench Footing
Risk
6"
OPTIONAL WALL CAP
h Site Wall
T QX—..QZPj';jTA
teg_QW3 I SAFETY DEPT.
e JOWROVED
FOR CONSTRUCTION
DATE - BY
#6 STD. LADDER TYPE
(#5 STD FOR SLUMPSTONE)_
JOINT REINF. AT TOP COURSE,
AT FIRST COURSE, AND 24"o.c.
6" WIDE (NOM.) CMU
GROUT CELLS
w/ REINF.
'X' BARS PER
SCHEDULE ® -
CTR. OF WALL
'Y' BARS PER
SCHEDULE LAP
PER 'L'
F.G.
WET -SET FIRST
COURSE
2-#4 CONT.—
SEE DETAIL SHEET 5-5.1.
IINIMUM DEPTH 'D' 0 SLOPE '.�/ E( GOv LAi.lv1DT T.
SLOPE SETBACK j `( SAF�
o'—o' 1 —o" L1ILDING &
2 :1 2'-6' 2'-0" B C�ONTCONC FTrG�y,--
3 :1 2'-0"
16-f ION
RY FENCE
i' MAX.A
oMR.)
LI
MI
16" LONG CMU 18' LONG CMU TYPE PER 5-2.0
16" LONG CMU
B' LONG CMU
Jym
6'-0"
#4048"o.c.
#4054"o. c. A'
4®24o.c.
�q c.
B'
4048-o.c.
4®54 o.c.
2'-2"
A'
4016"oxc
4018"o.c.
2'-0"
3'-0"
6'-8"
//4®48"o.c.
#4®45"o. c.
B'
4048"o.c.
4054"o.c.
27-0"
2'-4"
4016"o.c.
4®18"o.c.
3'-0"
3'-2"
7'-4"
#4048"o.c.
#4045"o.c.A'
'B'
4048"o.c.
4045"o.c.
2'-0"
2'-5"
A'
408"o.c.
409"o.c.
3'-4"
3'-5"
"
#4040"o.c.
#4036"o.c.
'B'
4040"o.c.
4036"o.c.
2'-0"
2'-7"
ANDERSON
DESIGN
GROUP
Structural Engineering Building Design
228 East Badlllo Street
• Covina • CA
• 91723-2115
(626) 938-1595 •
Facsimile
(626) 938-0485
engineering
excellence .Ince
1957 -
SETBACK
PER
SCHED.
J
w
x
U
J V)
w
a
MIN.
8„ l 5'-0" MIN.
CONT. TO DAYLIGHT
Q -g( ESS
34
* P.. 31 1
s
T RUCT
F �F- C SFO
DATE SIGNED 6-25-14
S-1.2LQ
#6255
(440- t a f. 2)
d4
BLOCK CO., INC.
3 Slnce 198
ANGELUS BLOCK MASONRY FENCE WALL SYSTEM
END OF WALL
� O 5�
8' High Max. Site Wall
C ® 100mph
Risk Category I
6" Wide CMU
F
ou
„-E DEPT.
r-Oi- '0,`JS I UC T 10N
_ = B
`r
Y
A
x
x
N
RETURN TYP.
5xHF 5xHF O 5xHF
TYPICAL REINFORCED WALL STEM TYPES PLAN
WALL TYPES O & O
TOTAL WALL LENGTH
+ 3�
r 5 x HF MIN.
Z
M
L
X
0
W
z
a
TYPICAL REINFORCED WALL STEM TYPES ELEVATION
WALL TYPES n & n
ANDERSON DESIGN GROUP
Structural Engineering Building Design
228 East Badillo Street • Covina • CA • 91723-2115
(626) 938-1595 Facsimile (626) 938-0485
engineering excellence since 395]-
" LA
� OF
,JiLC,NG & SAI
A�DP0
FOF3 CONSni
5 x Hr MIN.
(pi4 2