Loading...
BWFE2014-111178-495 CALI.E TAMPICO D 4v� � VOICE (760) 777-7125 LA QUINTA,TCALIFORNIA 92253 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/17/2014 Application Number: BWFE2014-1111 Owner: Property Address: 53210 AVENIDA DIAZ 3 BOULDERS APN: 774042011 45311 GOLF CENTER STE B Application Description: 42 LF. 5'& 24 LF 4' GARDEN WALL INDIO, CA 0 Property Zoning: Application Valuation: $1,800.00 Applicant: Contractor: 3 BOULDERS CORONEL ENTERPRISES 45311 GOLF CENTER STE B 51105 AVENIDA VILLA 101 INDIO, CA 0 LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.::LIC-000 4 Date: �L�—�-1—�i Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not, intended or offered for sale. If, however, the building or improvement is sold within bne year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_)I, as owner of the property, am exclusively contracting with licensed contractors to cohstruct the project. (Sec. 7044, Business and Professions Code: The Contractors' StatE License Law does not apply to an owner of property who builds or improves - ther@on, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (-J I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)775-1230 Llc. No.: :LIC -0000254 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and ag a that, if I should become pubb)'ect to the workers' compensation provisions ofSec i n 3700 of the L CodII forthwith comply with those provisions. Date: 1 u—\-1 - 1"A Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or.pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relati_W to building construction, and hereby authorize representativesd� tt i city tenter on the bo mentioned property for inspection purposes. Date: -Signature (ApplicantorAgentt. �J v DESCRIPTION FINANCIAL INFORMATION ACCOUNT CITY AMOUNT PAID PAID DATE BSAS 681473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY • METHOD RECEIPT # CHECK # CLTD BY Total Paid for FENCE OR FREESTANDING WALL- $108.77 $0.00 TOTALS:0• i 00 Permit Details PERMIT NUMBER r City of La Quinta BWFE,,2014 `1111 Description: 42 LF. S'& 24 LF 4' GARDEN WALL CONDITIONS CONTACTS Type: WALL/FENCE Subtype: Status: APPROVED Applied: 10/17/2014 KHE Approved: Parcel No: 774042011 Site Address: 53210 AVENIDA DIAZ,CA Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 177 Lot: 14 Issued: UNIT 18 EMAIL APPLICANT Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $1,800.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 42 L.F. 5' GARDEN WALL & 24 L.F.' GARDEN WALL AT PROPANE TANK AND POOL EQUIPMENT, CITY STANDARD CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT 3 BOULDERS 45311 GOLF CENTER INDIO CA 0 STE B CONTRACTOR CORONEL ENTERPRISES 51105 AVENIDA VILLA LA QUINTA CA 92253 101 OWNER 3 BOULDERS 45311 GOLF CENTER INDIO CA 0 STE B Printed: Friday, October 17, 2014 9:04:29 AM 1 of 2 CRWsrsrEMS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE ATTAC H M E NTS Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS NOTES SEQID INSPECTION TYPE CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID I- PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 FINAL" Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: WALL/FENCE - FIRST 101-0000-42404 0 $47.86 $0.00 100 LF WALL/FENCE - FIRST 101-0000-42600 0 $60.91 $0.00 100 LF PC Total Paid for FENCE OR FREESTANDING WALL, $108.77 $0.00 TOTALS:0• 00 REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE ATTAC H M E NTS Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS NOTES SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE INSPECTIONS COMPLETED DATE RESULT REMARKS FOOTINGS BOND BEAM FINAL" REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE ATTAC H M E NTS Printed: Friday, October 17, 2014 9:04:29 AM 2 of 2 CN?WYSTEMS e ac O W , Z O G Z Q ALUMINUM SPIRAL SIAIRS INSIALLED BY MANUFACTURERS SPECS. h DIE Ilrorr SfIL)r rdr_)IE.) I a N O Y W m U z_ O p o � 3 w C? C, a C ti a Q W - o Z • 3 APN.:774-042-023 PROPOSED 6' Block Wall [By separate Permit] SWALE MINIMUM (1) ONE % APN.:774-042-011 .:::::...........:.::::.. 0 0 w (1) 24" BOX f _.... _...........�, ,,.... � PI QINT SHOESTRING ACACIA PERMIT AND INSPECTION BY CITY OF LA (ACACIA STENOPHYLLA) QUINTA PUBLIC WORMS THE DEVELOPER/CONTRACTOR/OWNER j IS RESPONSABILE FOR THE VERIFICATION OF EXISTING CURB (OR EDGE OF STREET U N `,I e a� Lu F Z O (` CC L _Z w 3 N Lu Z O 2 � a Q i _z W 0Z CN O W N Q 3� O W 10 D'a7 Z Z a n+ al O. _ Q X -- _ � o .:::::...........:.::::.. 0 0 w (1) 24" BOX f _.... _...........�, ,,.... � PI QINT SHOESTRING ACACIA PERMIT AND INSPECTION BY CITY OF LA (ACACIA STENOPHYLLA) QUINTA PUBLIC WORMS THE DEVELOPER/CONTRACTOR/OWNER j IS RESPONSABILE FOR THE VERIFICATION OF EXISTING CURB (OR EDGE OF STREET BLO*�94: C. ANGELUS BLOCK MASONRY FENCE WALL SYSTEM IESIGN CRITERIA: DESIGN CRITERIA PER 2013 CBC :. ALLOWABLE SOIL BEARING PRESSURE = 1500psf i. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf i. CANTILEVER ACTIVE = 30pcf i. MASONRY COMPRESSIVE STRENGTH, f'm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. TOTES: REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. !. JOINT REINFORCEMENT ("LADDER- TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. S. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. I. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. S. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. i. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF GOpsi. Z, O 00 PS lr 1. . IRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 3. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. ). VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED ). GROUT ALL CELLS WITH REINFORCEMENT. I. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. >-. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS 6' to 8' H Trench Footing Risk 6" OPTIONAL WALL CAP h Site Wall T QX—..QZPj';jTA teg_QW3 I SAFETY DEPT. e JOWROVED FOR CONSTRUCTION DATE - BY #6 STD. LADDER TYPE (#5 STD FOR SLUMPSTONE)_ JOINT REINF. AT TOP COURSE, AT FIRST COURSE, AND 24"o.c. 6" WIDE (NOM.) CMU GROUT CELLS w/ REINF. 'X' BARS PER SCHEDULE ® - CTR. OF WALL 'Y' BARS PER SCHEDULE LAP PER 'L' F.G. WET -SET FIRST COURSE 2-#4 CONT.— SEE DETAIL SHEET 5-5.1. IINIMUM DEPTH 'D' 0 SLOPE '.�/ E( GOv LAi.lv1DT T. SLOPE SETBACK j `( SAF� o'—o' 1 —o" L1ILDING & 2 :1 2'-6' 2'-0" B C�ONTCONC FTrG�y,-- 3 :1 2'-0" 16-f ION RY FENCE i' MAX.A oMR.) LI MI 16" LONG CMU 18' LONG CMU TYPE PER 5-2.0 16" LONG CMU B' LONG CMU Jym 6'-0" #4048"o.c. #4054"o. c. A' 4®24o.c. �q c. B' 4048-o.c. 4®54 o.c. 2'-2" A' 4016"oxc 4018"o.c. 2'-0" 3'-0" 6'-8" //4®48"o.c. #4®45"o. c. B' 4048"o.c. 4054"o.c. 27-0" 2'-4" 4016"o.c. 4®18"o.c. 3'-0" 3'-2" 7'-4" #4048"o.c. #4045"o.c.A' 'B' 4048"o.c. 4045"o.c. 2'-0" 2'-5" A' 408"o.c. 409"o.c. 3'-4" 3'-5" " #4040"o.c. #4036"o.c. 'B' 4040"o.c. 4036"o.c. 2'-0" 2'-7" ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badlllo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 engineering excellence .Ince 1957 - SETBACK PER SCHED. J w x U J V) w a MIN. 8„ l 5'-0" MIN. CONT. TO DAYLIGHT Q -g( ESS 34 * P.. 31 1 s T RUCT F �F- C SFO DATE SIGNED 6-25-14 S-1.2LQ #6255 (440- t a f. 2) d4 BLOCK CO., INC. 3 Slnce 198 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM END OF WALL � O 5� 8' High Max. Site Wall C ® 100mph Risk Category I 6" Wide CMU F ou „-E DEPT. r-Oi- '0,`JS I UC T 10N _ = B `r Y A x x N RETURN TYP. 5xHF 5xHF O 5xHF TYPICAL REINFORCED WALL STEM TYPES PLAN WALL TYPES O & O TOTAL WALL LENGTH + 3� r 5 x HF MIN. Z M L X 0 W z a TYPICAL REINFORCED WALL STEM TYPES ELEVATION WALL TYPES n & n ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badillo Street • Covina • CA • 91723-2115 (626) 938-1595 Facsimile (626) 938-0485 engineering excellence since 395]- " LA � OF ,JiLC,NG & SAI A�DP0 FOF3 CONSni 5 x Hr MIN. (pi4 2