Loading...
11475 (SFD)P.O. BOX 1504 No 11475 Building 78-105 CALLE ESTADO Address 53-240.Ave. Herrera LA QUINTA, CALIFORNIA 92253 Owner David Ross Miller Mailing BUILDING: TYPE CONST. OCC: GRP. - Address P.O. Box 772 774-054-012 A.P. Number City Zip Tel. �,fl $� 217 La Quirst 92253 Legal Description ContractorPacific Trades Project Description 'SFB Address SAS City-- Zip Tel.: State Lic. City &Classif.$4253$2 Lic.# 1955 Sq. Ft. , No. No.Dw. Size +365 Stories Units Arch., Engr., Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. Permit does not inc.l2de block walls, City Zip State patio cover, or pool. Lic. # w LICENSED CONTRACTOR'S DECLARATI61NI I herebyirm that I ;am licensed undek Provisions bf Chapter 9 (commiancing with Section 7000) of DivislRZ ofgt b,8;u'siness and Professions Code, and my license is in full force and effecL�J ��Y N SIGNATURE \ DATE OWNER -BUILDER DECLARATION Estimated Valuation 82,668.50 1 hereby affirm that I am exempt from the Contractors License Law for the following reason: (sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to'its Issuance also requires the applicant for such permit to file a signed statement that he'is licensed'pursuant to PERMIT - AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basistt ti for the alleged exemption. Any violation of Section 7031.5 by 'any applicant fora permit Plan Chk. Dep. - 250 x.00 subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). . • x Z • r O I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. do the work, and the structure is not intended or offered for sale. (Sec' 7044, Buisness and Const. •i _ �J� • r%�i Professions" Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does, such work himself or'through his own employees, Mech. 1 r •. 5 5 - provided that such improvements are not intended or offered for sale..lf, however, the building _ or Improvement is sold within one year of completion, the owner -builder will have the burden `'Electrical r 3.�� • 58 of proving that he did not build or improve for the purpose of sale.) 0 I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing 141 • 00 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. B. 30 such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) " Grading I� • ix ❑ 1 am exempt under Sec. B. & P.C. for this reason Driveway Enc. Date owner Infrastructure . r .i� • 9 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of \ 213.24 � • ?� t Workers compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) s of cy No. Company - C-opy is filed with the city. ❑ Certified copy is hereby furnished. \�✓/ TOTAL _ +..�.--.--- CERTIFICATE OF EXEMPTION FROM REMARKS = r WORKERS' COMPENSATION INSURANCE (This section need not be completed ff the permit is for one hundred dollars '($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation ' Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY: subject to the workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked.' Front Setback from Center Line Rear Setback from Rear Prop. Line " CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE \ INSPECTOR This Is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application' and state that the above information is correct. Issued by:Date Permit I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above.. imentioned property for inspection purposes. Validated by: Signature of applicant Date j Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ UNITS SLAB GRADE 0V 2ND FL SO. FT. ® BONDING YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SQ. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. ® GAS (ROUGH) DRAINAGE PIPING WALL SO. FT. OTHER APPJEOUIP. DRINKING FOUNTAIN. SO FT ® TEMP. POLE tl URINAL ESTIMATED CONSTRUCTION VALUATION $ GROUT WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. FLOOR DRAIN MECHANICAL FEES WATER SYSTEM WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FRAMING , 1 [ GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED D� n / 1 �/ ca4D c 17� �O-T S, �J i�i31 R 3 L0 LAUNDRY TRAY AIR HANDLING UNIT CFM REMARKS: KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 Ya c SEWAGE DISPOSAL SO.FT.GAR ® 3Ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE T STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK LVI GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE 0V ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER ` PJ)U H WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE tl GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP.43- Q C FRAMING , 1 [ FINAL INSP. ROOFING J D� n / 1 �/ ca4D c 17� �O-T S, �J i�i31 R 3 L0 r N ^ ✓ �" //�J r�� REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL THING aq -la Cb MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION- L CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 111/24/921 Type of Permit I La Quinta No. 111865 1 Permit # 11475 Owner Name David Miller Log No. 53240 Street Herrera City La Quinta Zip 92253 Study Area 111 APN # I Tract # Lot # 0 Square Footage 11365 Type of Development Single Family Residence I No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.58 x 1 65 or $ 2,156.70 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By David Miller Telephone Name on the check By lames E. Lively Assistant Superintendent, Business Services 4 Fee collected /exem by L ne rthur Payment Received-; Signature4A& CnEdk: MO..37:80 ;,. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/ Receipt Copy - Accounting ,4, it '40r, e At it (#z V � of t7/-Crrr,. Tit� of 14a(Quinta Ilutntug dub �'dfet� 3403h.41*13n This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 53-240 Herrera Use Classification Single Family Dwelling Bldg. Permit No. 11475 Group R3 Type Construction VW Fre Zone Use Zone SR Owner of Building David Ross Miller Address P.O. BOX 722 City La uinta CA' 92253 By; Lonnie Day Date: February 1, 1993 Building Official POST IN A CONSPICUOUS PLACE Ohl IMI= >MPUTER METHOD SUMMARY Standard Page 1 C -2R oject'Titls.......... DAVE MILLER'. -^ Date........ 08/12/92 oject Address.,..,,.. LA QUINTA ---------------------- 3.16 = = Space Cooling.......... 52.34 40.87 11.47 -. )cumentation Author... W J FINNELL ; Building Permit # ; )mpany. ................ ENERGY CONSULTING GROUP 74.25 i ;lephone.............. 800-262-9966 ; Plan Check-/ Date ; -------------------------- Floor # of Vent ampl„Ance Method...... MICROPAS3 by Enercomp., Inc. ' Field Check/ Date timate` Zone........... 15 -------------------- MICROPAS3 v3.11 File-DAVEMIL Wth-CTZ15 Program -FORM C -2R ; User#-MP1325 User -ENERGY CONSULTING GROUP Run -DAVE MILLER MICROPAS3 ENERGY USE SUMMARY ---------------------------- - Enerny Use Standard Proposed Compliance = _ (k9tu/sf-yr) Design Design Margin = _ Space Heating.......... 8.21 5.05 3.16 = = Space Cooling.......... 52.34 40.87 11.47 -. - Water Heating........... 13.70 26.39 -12.69 = = Total 74.25 72.31 1.94 = _* Building complies with Computer Performance GENERAL INFORMATION -------- ------ Conditioned Floor Area..... '1365 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (w) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type..... Slab On Grade (Package D) Number of Building Zones... 1 Conditioned Volume......... 12285 of Footprint Area ............. 1365 sf Slab -On -Grade Area......... 1365 sf Glazing Percentage......... 7.5 % of FA Average Ceiling Height..... 09 ft. BUILDING ZONE INFORMATION -------------------------- Floor # of Vent Special Cond- Area Volume Dwell Thermostat Height Vent Area Zone Type itioned (sf) (cf) Units Type (ft) (sf) ;OUSE Residence Yes 1365 12285 0 1.00 Setback 2.0 n/a GLAZING SURFACES Area Shading SC of Surface (sf) Type APUTER METHOD SUMMARY. SC Area Page 2 C -2R eject Title.......... DAVE MILLER Act 0.84 Date......:. 08/12/92 ^- MICROPAS3 v3.11 File-DAVEMIL Wth-CTZ15 Panes program -FORM C-211 ; value User#-MP1325 User -ENERGY CONSULTING Tilt GROUP Run -DAVE MILLER Shade iOUS E OPAQUE SURFACES Areae U- --------------- Insul Act -Solar 33.0 Location/ Form 3 irface (sf) value R-val Azmth Tilt Gains Comments Reference ,USE 2 Metal Slider 0.65 0 90 0.77 I Wall 239 0.065 R-19 270 90 Yes OUTSIDE None - wall 152 0.065 R-19 270 90 No GARAGE None 3 Wall 408 0.065 R-19 0 90 Yes OUTSIDE None 4 wall 408 0.065 R-19 90 90 Yes OUTSIDE None 5 Wall 80 0.065 R-19 180 90 Yes OUTSIDE None 3 Wall 160 0.065 R-19 180 90 No GARAGE None 7 Roof 1438 0.029 R-38 0 0 Yes ATTIC None B Door 20 0.330 R-2 270 90 Yes OUTSIDE None 9 Door 20 0.330 R-2 180 90 No GARAGE None PERIMETER LOSSES Length ---------------- F2 Insul Surface (ft) Factor R -vat Location/Comments HOUSE 10 SlabEdge 41 0.900 R--0 TO OUTSIDE 11 SlabEdge 118 0.720 R-0 TO OUTSIDE 12 SlabEdge 30 0.550 R-0 TO GARAGE 13 SlabEdge 13 0.500 R-0 TO GARAGE GLAZING SURFACES EXTERIOR SHADING Area Shading SC of Surface (sf) Type SC Interior SC Area # of Frame Open U- Act 0.84 Glass Shade GIs+ surface (sf) Panes Type Type value Azmth Tilt Only Type Shade iOUS E 1 Window 33.0 2 Metal Slider 0.65 270 90 0.77 drapes 0.66 2 Window 14.0 2 Metal Slider 0.65 0 90 0.77 drapes 0.66 3 Window 36.0 2 Metal Slider 0.65 90 90 0.77 drapes 0.66 4 Window 20.0 2 Metal Slider 0.65 180 90 0.77 drapes 0.66 EXTERIOR SHADING a Area Shading SC of Surface (sf) Type Ext Shade HOUSE 1 Window 33.0 50% bug scrn 0.84 2 Window 14.0 50% bug scrn 0.84 3 Window 36.0 50% bug scrn 0.84 4 Window 20.0 506 bug scrn 0.84 a )MPUTER- METHOD SUMMARY Page .3 CL ZR ,oject Title.......... DAVE MILLER Date.`........ 08/12%92 _MICROPAS3 v3.11 File-DAVEMIL Wth-CTZ15 Program -FORM C -2R User#-MP1325 User -ENERGY CONSULTING GROUP Run -DAVE MILLER THERMAL MASS ------------ e Area Thick Heat Conduct- Surface ------------ Minimum ass Type (sf) (in) Cap ivity R -value Location/Comments FUSE HOUSE HeatPump 1 S1abOnGrade 573 3.5 28.0. 0.98 R-0 KIT/DINE/BATHS 2 S1abOnGrade 792 3.5 28.0 0.98 R-2 REST OF HOUSE 3 InteriorHorz 42 1.0 24.0 0.67 R-0 KITCHEN/BATHS e HVAC SYSTEMS ------------ Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE HeatPump 8.0 HSPF Attic R-5 0.828 AirCond 10.00 SEER Attic R-5 0.818 WATER HEATING SYSTEMS Capa- --------------------- R-12 or Pilot ystem # of city Greater Effic- Standby Input Size ype Heat (gal) Blanket iency Loss Rating (Btuh) Credits torage Electric 1 37 No 0.99 RE .82% 4.5 kW n/a None SPECIAL FEATURES/REMARKS ------------------------ e ERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R -oject Title.......... DAVE MILLER Date.....:. 08/12/92, ,oject Address........ LA QUINTA--------------------- ocumentation Author..,.W J FINNELL ; Building Permit # ; =pany................ ENERGY CONSULTING GROUP eiephone.............. 800-262-9966 Plan Check / Date ; ampliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ; limate Zone.... .. 15 ..... --------------------- ------------ MICROPAS3 v3.11 File-DAVEMIL Wth-CTZ15 Program -FORM CF -1R - -- ; User#-MP1325 User -ENERGY CONSULTING GROUP Run -DAVE MILLER ; - ----------------------------------------------------------------------- ------ GENERAL INFORMATION ------------------- Conditioned Floor Area..... 1365 sf Building Type.... ... Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION ---------- --------------- Component Insul Type R -value Location/Comments Wall R-19 OUTSIDE; GARAGE Roof R-38 ATTIC Door R-2 OUTSIDE, GARAGE SlabEdge R-0 TO OUTSIDE, TO GARAGE GLAZING 31azing Area # of Interior Exterior Framing orientation (sf) Panes 'Shading Shading Overhang Type ------------------- Kindow Front (W) ------ 33.0 ----- 2 ---------- drapes --------------- 50% -------- bug scrn None -------- Metal Window. Left (N) 14.0 2 drapes 50% bug scrn None Metal Vindow Back (E) 36.0 2 drapes 509 bug scrn None Metal Vindow Right (S) 20.0 2 drapes 506 bug scrn None Metal THERMAL MASS Area Thickness ------------ Hard Surfaced/ Type ------ (sf) --------- (in) Exposed -------------- Location/Comments ------------------------ ------------ SlabOnGrade 573 3.5 Yes KIT/DINE/BATHS S1abOnGrade .792 3.5 No REST OF HOUSE InteriorHorz 42 1.0 Yes KITCHEN/BATHS s M i RTIFICATE,OF COMPLIANCE: RESIDENTIAL. Page 2 CF -1R oject- Title .......... DAVE -MILLER Date. 666.4. 08/12%92 MICROPAS3 V3.11 File-DAVEMIL Wth-CT2i5 Program -FORM CF -1R User#-MP1325 ----------------------- User -ENERGY CONSULTING GROUP ------------------------------------- Run -DAVE MILLER -----------_----_-- ASSUMED HVAC SYSTEMS -------------------- Assumed Duct Duct Assumed System '.Efficiency Location R -value HeatPump 8.0 HSPF Attic' R-5 A i rCond 10.00 SEER Attic R--5 Actual System --------------- Heating Cooling Coaling Coil ACTUAL HVAC SYSTEMS -------------------- Actual Output Manufacturer and Model # Efficiency (Btuh) (or approved equal) ------------ -------- --------------------------------- CEO Maximum output for Gas Central Furnaces: WATER HEATING SYSTEMS --------------------- Tank R-12 or # of Vol Greater Manufacturer and Model # ystem Type Heat (gal) Blanket (or approved equal) Storage, Electric 1 37 No SPECIAL FEATURES/REMARKS ------------------------ 40 Btuh Energy Credits None ;RT~IFICATE OF COMPLIANCE: RESIDENTIAL Page 3 OF' 1R x ' -oject. Title.......... DAVE MILLER . Date........ 08/12/92 - MICROPAS3 v3.11--File-DAVEMIL-yWth-CTZ15--Program-FORM CF -1R User#-MP1325 User -ENERGY CONSULTING GROUP. Run -DAVE MILLER COMPLIANCE STATEMENT - This certificate of compliancelists the building features and performance specifications needed to comply with-Title.24; Chapter 2-53 and Title 20,j Chapter 2, Subchapter 4,.Article 1 of -the California Administrative code;. This certificate. has been signed by -the individual with overall design responsibility and the building owner, who shall retain a copy of it and, transmit the certificate to any subsequent purchaser of the building. When; this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER OWNER Name.... Name.... W S . iiLo"5 Company.Company. aL%EtL 7TL.A,��.S ; Address. Address. -0.-. -Z-,v Phone... Phone...4, t,%4 — License. Signed Signed S (date) (date) DOCUMENTATION AUTHOR ENFORCEMENT AGENCY Name.... W J FINNELL Name.... Company. ENERGY CONSULTING GROUP Title... Address. 34F INDIAN HILLS Agency.. MTN CENTER, CA 92561 Phone... 800-262-9966 Phone... Signed 9_/1 Lh Signed '(date) (date) TER. HEATING Page 1 DHW' i oject Title.......... DAVE MILLER Date........ 08/12/921 oject Address........ LA QUINTA------------------ --. t �cumentation Author... -W J FINNELL ; Building Permit # ; ,mpany................ ENERGY CONSULTING GROUP ; s :lephone.............. 800-262-9966 I Plan Check / Date ,mpiiance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date imate Zone........... 15 ------------------=-- ---MICROPAS3-v3.11 File-DAVEMIL Wth-CTZ15 -Program-WATER HEATING --�- User#-MP1325 User -ENERGY CONSULTING.GROUP Run -DAVE MILLER .-_-------------------------------•-------------------------------------------- WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA ----------------- 1. Water heater type....... 2. Manufacturer............ 3. Model number............ 4. Ignition device......... 5. Tank volume... ......... 6. Recovery efficiency..... 7. Standby loss............ 8. Rated input.. .......... 9. Number of Heaters....... 10.Insulation Jacket....... Storage, Electric n/a 37 gal .99 percent x 0.01 .0082 percent/hour x0.01 15358.5 Btu/hr MC B. OPERATING DATA ----------------- 1. Climate Zone....... .... 2. Water heating budget.... 3. Tank set temp........... 4. Water main temp. .. ... 5. Daily hot water load.... S. Ambient air temp........ 7. Adj. Standby Losses..... 8. No. dwelling units...... 9. Pump power .............. 10.Pumping energy.......... 15 18700 kStu/yr/unit 140 F 70 F 50 gal 72.6 F .0082 1 0 Watts (0 Watts controller) 0 Watt-hr/yr (0 hr per day) C. WATER HEATING ENERGY CREDITS 1. Credit Name ............. None 2. Annual savings.......... 0 kBtu/yr/unit D. ANNUAL WATER HEATING ENERGY 1. ------------------------------ Recovery load........... 10539 kBtu/yr 2. Recovery energy......... 10646 ketu/yr 3. Standby loss energy..... 1361 kBtu/yr 4. Pumping energy.......... 0 kBtu/yr source 5. Total energy............ 36020 kBtu/yr,/unit source 6. Comparison .............. -17320 kBtu/yr/unit source 7. Points... ......... ... -25 8. Water Heating Energy Use 26.39 kBtu/yr/sf (D5 x 68) / 1365 sf i 40SIZING Page 1 HVAC eject Title .......... -DAVE MILLER=====---------'___= V= -Date ........ 08/12%92 eject Address........ LA QUINTA------------------�-- cementation Author... W J FINNELL Building Permit # mpany................ ENERGY CONSULTING GROUP lephone.............. 800-262-9966 ; Plan Check / Date ; mpliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date ; imate Zone......... . 15 ------------------' • i-- MICROPAS3 v3.11 File-DAVEMIL Wth-CTZ15 Program -HVAC SIZING ; User#-MP1325 U.ser-ENERGY CONSULTING GROUP Run -DAVE MILLER - ------------------------------ - ------ --------------------------------------- GENERAL INFORMATION Floor Area ................. 1365 sf Volume ........ .......... . 12285 of Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ................... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 30 F Shading Used ............... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. 'It is the HVAC designer's responsibility to consider all factors when selecting `he HVAC equipment. -0 Maximum output applicable for gas central furnaces only Heating Cooling Description -------------------------------------------- (Btuh) (8tuh) ---�-------- Opaque Conduction and Solar...... 12047 5476 Glazing Conduction............... 2745 2276 Glazing Solar .................... n/a 4533 Infiltration ..................... 7244 4293 Internal Gain .................... n/a 2550 Ducts ............................ 2204 1913 Sensible Load .................... 24239 21041 Latent Load ...................... n/a 4208 Total Load- 24239 25249 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. 'It is the HVAC designer's responsibility to consider all factors when selecting `he HVAC equipment. -0 Maximum output applicable for gas central furnaces only MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project:Title.......... DAVE MILLER Date......... 01/13/92 Project Address........ LA QUINTA --------------------- Documentation Author... W J FINNELL ; Building Permit # Company ................ ENERGY CONSULTING GROUP Telephone...; ........... 1-800-262-9966 ; Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 --------------------- ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-DAVEMILL Wt.h-CTZ15 Program -FORM MF -1R User#-MP1325 User -ENERGY CONSULTING GROUP Run -DAVE MILLER ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. * 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. 2-5311: Insulation specified or installed meets CEC quality standards. Indicate.type and form. 2-5352(f): Vapor -barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c.. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation. of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... DAVE MILLER Date. -`{� 01/13/92 MICROPAS3 v3.11 File-DAVEMILL Wth-CTZ15 Program-FORMMF-1R User#-MP1325 User -ENERGY CONSULTING GROUP Run -DAVE MILLER ; --------------------------------------------------------=---------------------- HVAC AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * 2-5316(a). Ducts -constructed, installed and insulated per Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the.CEC. 2-5352(i): Water heater insulation blanket ( R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated to R-3.or greater). 2-5312(Exception I): Pipe insulation on steam and steam condensate return and recirculating piping. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. S. Directional water inlet. LIGHTING AND APPLIANCE MEASURES ------------------------------- Design- Enforce- er meet 2-5352(j): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 2-5314(c): Gas fired appliances equipped with intermittent ignition.devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamps ballasts certified by the CEC.