Loading...
05-1553 (SFD)0 .lbw"" rgr•� A; BUILDING & SAFETY DEPARTMENT D. Sw ox 1504 (760),777-7012 ISE78- CALLE TAMPICO FAX (760) 777-7011 ,UI TA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 c�NANc of BUILDING PERMIT pplication Number 05-00001553 Date 4/27/05 Property Address . . . 53330 AVENIDA HERRERA APN: 774-084-004-21 -000000- Application-description DWELLING - SINGLE FAMILY DETACHED. Property Zoning . . . . . . .COVE RESIDENTIAL Application valuation . . . 1.13704 Owner Contractor --------------------------------- --------------------------------- CORONEL ENTERPRISES 'CORONEL CONSTRUCTION P 0 BOX 389 P.O. BOX 389 LA QUINTA, CA 92253 LA QUINTA, CA 92247 (760)564-4604 WCC: STATE FUND WC: 174445305 01/01/06 CSLB: 634981 01/31/06 CCC: B -C13 Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 481.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 1823.00 ---------------------------------------------------------------------- - - - - -- OW P.O. Box 1504• �� VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4.4 QINSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT E;r'J Application Number: Applicant: Applicant's Mailing Address: 0 04 EWA D' e �-.S- ar _dam t ` Architect or Engineer _� �7. _IFII Architect or Engineer's Address: I WI= BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION iyaffirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals and my, license is in full force and effect. .-7— . Class (Z�� 7, S(1 — Lic! ens. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the'following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. BA P.C. for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is �� issued. My WQfkers' ompensafion_insurance carrier and policy number,are: �CarriT err �h �k � r–� I Policy Number" — I certify that, in the performance of'the-work`f& which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with tpgse provisions. /-- _ -v5 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2.. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abov information is correct. I agree to comp ith all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cou ty enter pon the ab - entioned ro erty for inspection purposes. Date S-7_,��c/5 Sigq ture_(Applica-t.Age t): -------------------------------------------------------------------------- -- Application Number . . . . . 05-00001553 ---------------------------------------------------------------------------- P Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 688.50 Issue Date . . . . Plan Check Fee 447.53 Valuation . . . . 113704 Expiration Date 10/24/05 Qty Unit Charge Per Extension . BASE FEE 639.50 14.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 49.00 Permit . . . . . . MECHANICAL Additional desc . . Permit Fee . . . . 59.00 Plan Check Fee 14.75 Issue Date . . . . Valuation . . . . 0 Expiration Date . . .10/24/05 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 103.43 Plan Check Fee 25.86 Issue Date . . . Valuation 0 Expiration Date 10/24/05 Qty Unit Charge Per Extension BASE FEE 15.00 1823.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 63.81 481.00 .0200" ELEC GARAGE OR NON-RESIDENTIAL 9.62 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . . PLUMBING Additional desc . . Permit Fee 135.00 Plan Check Fee 33.75 Issue Date Valuation . . . . 0 Expiration Date 10/24/05 Qty Unit Charge Per Extension BASE FEE 15.00 11.00 6.0000 EA PLB FIXTURE 66.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 ----------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 ---------------------------------------------------------------------------- Application Number . . . . . 05-00001553 521.89 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT .00 Expiration Date 10/24/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1823 SF. SFD PERMIT DOES NOT INCLUDE BLOCK WALL, POOL/SPA OR DRIVEWAY APPROACH ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 44.75 DIF FIRE PROTECTION -RES 97.00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC'- RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 11.37 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ------------------ Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 1000.93 .00 521.89 250.00 2481.12 .00 4003.94 250.00 Credited Due .00 1000.93 .00 271.89 .00 2481.12 .00 3753.94 •4 4v P.O. BOX 1504 APPLICATION ONLY Building t�-� _� , ^ �\ 78-495CALLCALIFORNIATAMPIO Address _ 1 l�\.i �- � c f e'C �. LA OUINTA, IORNIA 92253 4� A Mailing. - Address City Zip Tel. Contractors— ress State Lic. • City & Classif. yGj (I Lic. N �1 Arch., Engr., d� Designer Address Tel. City Zip State Lic. If r LICENSED CONTRACTOR'S DECLARATION reby affirm that I am licensed under provisions of Chapter 9 (commencing with Se tlo 7 ) of Division 3 of jaa Business and Professions Code, and my license is in full for a d NM -BUILDER DECLARATION I here ffir a exempt from the Contractors License Law for the f lowing reason: (Sec 031.5,Busin s and Professions Code: Any city or county which r quires a permit to cons cf, alter, i rove, demolish, or repair any structure, prior to 'its !ss once also requires the ap ' ant for s h permit to file a signed statement that he is licensed ursuant to the provisions of a Cc actor's License Law, Chapter 9 (commencing with Sect n 7000) of Division 3 0! the Btu s antl Pro/essions Code, or that. he is exempt therefrom, and the basis !or the alleged exAtnpfion. Any violation o/ Section 7031.5 by any applica lot a permit subjects the applicant o a civil penalty of not more than live hundred dollars ($500). !: I, as owner of the property, or my employees with wages as their sole c Inpensation, will do the work, and the structure is not intended or offered for sale. (Sec. 044, Buisness and Professions Code: The Contractor's License Law does not apply to an ow er of property who builds or improves thereon and who does such work himself or through his own employees, provided that such Improveme@nts are not intended or offered for sale. If however, the building or improvement is sold wffh1h,pne year o! completion, the owner -build r will have the burden o! proving that he did not build or\mprove for the purpose of sale.) II I, as owner of the property, am exclusively contracting with lic nsed contractors to con- struct the project. (Sec. 7044, \Business and Professions Code: T e Contractor's License Law does not apply to an owner of property who builds or improves fh reon, and who contracts for such projects with a contractor(s) lice Sed pursuant to the Contractor' License Law.) I'! I am exempt under Sec. � B. & P.C. for this re on Date Owner WORKERS' COMPENSATIONECLARATION I hereby affirm that I have a certificate of co sent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified co thereof. (Sec. 3800, Labor Code.) Policy No. Company [l Copy is filed with the city. ❑ Certified c y is hereby furnished. CERTIFICATE OF EMV,TION FROM WORKERS' COMPE SATION INSURANCE (This section need not be completed if the ermif is for one hundred dollars ($100) valuation or less.) I certify that in the performance of t work. for which this permit is issued, I shall not employ any person in any manner so a to become subject to the Workers' Compensation Laws of California. \\ Date Owner NOTICE TO APPLICANT: If, after king this Certificate of\Exempfion you should become subject to the Workers' Compens ion provisions of the Labor Code, you must forthwith comply with such provisions or this pQ if shall be deemed revokedA NSTRUCTION LENDING AGENCY I hereby affirm that th a is a construction lending agency for he performance of the work for which this permit s issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building rIn t when properly filled out, signed and validate and is subject to expiration if work the eunder is suspended for 180 days. I certify that 1 hav read this application and state that the above inform tion is correct. I agree to comply ith all city and county ordinances and state laws relatt to building construction, an hereby authorize representatives -of this city to enter he above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE -CONST. OCC. GRP. A.P. Number —7"-A `V-A —00--i Legal Description \—A _,�L_� Project Description S • - 1 Sq. Ft. \i� -� Size New �' Add ❑ imated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS G;\. No. l StnriPs Alter ❑ Repair ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE City Zip Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street .Unit 1 53330 Avenida Herrera Unit 2 Unit 3 Unit 4 Unit 5 S.F. Lot # No. 1823 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Comments Certs #27231 and 27232 used for #349014 in the amount of $7,474.88. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,823 S.F. or $4,083.52 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Rabobank - Ish Coronel Check No. 349014 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by S Mc Ivrey Payment Reed $4,083.52 Over/Under Signature r7l NOTICE: Pursuant to Government Code Section 66020(d)(1), this\4,41 serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting APR -26-2005 TUE 08:56 AM Coronel Construction RECORDING REQUESTED BY. F� fidelity National Title Company EECioW No, 9850 -KC TRIe Order No_ gajtmS! 1�1 When Recorded (Mail Document and Tax Statement To: Coronel Enterprises, Inc. 51185 Avenida Villa La Quinta, CA 92253 FAX No. 760 564 4202 P-012 000 = 2005_0228196 03/23/2005 08:00A Fee:10.00 Page 1 of 2 Doc T Tax Paid Recorded in Official Records County of Riverside L.arry W. Ward Assessor, County Clerk & Recorder ArjN: / /,+-vo,+-uu,4-u uzu-u 1 z) GRANT DEEU or"''` Aovvc 1 n10 L11ML r ,.. .� .....�., D The undersigned grantor(s) declare(s) 9 Documentary transfer tax is $181.50 S� [ X I computed on full value of property conveyed, or I computed on full value less value of liens or encumbrances remaining at time of sale, ) City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, James E. Burke and 'vaientitia I_ Burke, Trustees, in trust, pursuant to the terms of the James E. Burke and Valentina I. Burke Family Trust, dated December 15, 1989, and any amendments thereto -hereby GRANT(S) to Coronel Enterprises, Inc., a California Corporation the following described real property in the City of La Quinta County of Riverside, State of California: Lot 21, Block 226, SANTA CARMELITA AT VALE LA QUINTA,, UNIT NO. 21, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 20, PAGE 22 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. DATED: February 25, 2005 STATE OF CALIFORNIA COUNTY OF ON before me, lox personally appeared Al 6 personally known to me (or proved to me on the basis o satin actory evid--an—cel to be the person(s) whose names) ,Pg/are subscribed to the within instrument and acknowledged to me that Pit/sfte/they executed the same in bars/Ker/their authorized capacity(ies), and that by Vw/Itr/their signatures) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. Wtne4s my hand and official seal. Signature James E. Burke and Valentina I. Burke, Trustees, in trust, pursuant to the terms of the James E. Burke and Valentina f. Burke Family Trust, dated December 15, 1983, and any amendments the /01,6mes Burke, Trustee Valentina 1. 1311e, Trustee MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7196) GRANT DEED JANE F. BU129DD d Commission 1 5767 ��..'�. Not ry ubllc • Cotornia b Los Angeles MarCounty 29 Con'u'n. ExpifF�s Mar 29.2.!X75 nfrwgpMy MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7196) GRANT DEED Certificate of Occupancy 4 G� OF'TBuilding & Safety Department This Certifica&F is issued pursuant to the requirements of Section 109 of the California Buildh g Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-330 AVENIDA HERRERA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-1553 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RC CORONEL CONSTRUCTION Address: P.O. BOX 389 City, ST, ZIP: LA QUINTA, CA 92247 By: KIRK KIRKLAND Date: MARCH 6, 2006 Building Official ` POST IN A CONSPICUOUS PLACE I TITLE 24 REPORT I Title 24 Report for: Coronel Enterprises Inc. Taos -All Orientations La Quinta, CA 92253 Project Designer: Stephen R. Nieto 78-120 Calle Estado Ste. 206 La Quinta, CA 92253 760-564-4707 Report Prepared By: Stephen R. Nieto South West Concepts 78120 Calle Estado, Suite 206 La Quinta, CA 92253 (760) 564-4707 Job Number: 1823 Date: 4/20/2005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE4ZA -05 BY S_ O F'G'lcc The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 1823 User Number: 5970 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number: 1823 User Number: 5970 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Coronel Enterprises Inc. 4/20/2005 Project Title Date Taos -All Orientations La Quinta Project Address Building Permit # South West Concepts (760) 564-4707 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,823 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1}823 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Tvne Tvpe U -Value (attic, garage, typical, etc. R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front 40.0 0.48 0.58 Bug Screen Q ❑ ❑ Q Front 12.0 0.35 0.59 Bug Screen Q ❑ ❑ a Left 49.0 0.50 0.58 Bug Screen ❑ 0 ❑ Q Left 9.0 0.87 0.70 Bug Screen ❑ Q ❑ Q Left 33.4 0.48 0.58 Bug Screen ❑ Q ❑ Q Left 10.0 0.35 0.59 Bug Screen ❑ 0 ❑ Q Rear 33.4 0.48 0.58 Bug Screen ❑ 0 ❑ o Rear 26.0 0.35 0.59 Bug Screen ❑ 0 ❑ Q Right 12.0 0.57 0.67 Bug Screen ❑ El ❑ Q Right 36.0 0.50 0.58 Bug Screen ❑ Q ❑ 0 ❑ ❑ ❑ ❑ Run Initiation Time: 04/20/05 08:52:16 Run Code: 1114012336 Ener Pro 3.1 By Ener Soft User Number: 5970 Job Number: 1823 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Coronel Enterprises Inc. •4/20/2005 Project Title Date ` HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 89% AFUE Ducts in Attic 4-2 Setback Res HVAC Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Sethank Res HVAC WATER HEATING SYSTEMS Water Heater Water Heater Distribution Rated 1 # in Input Tank Cap. Energy Fact! 1 External or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A-0- SMIIH FPS -50-224 Small Gas Standard 1 43 000 50 060 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name Title/Firm: Stephen R. Nieto Address: 78-120 Calle Estado Ste. 206 a Quinta CA 92253 Telephon . 7 0-564-4707 Lic.%w #: z y zd aJ- (sig ure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Steohen R. Nieto Title/Firm: South West Concepts Address: 78120 Calle Estado, Suite 206 La Qui to CA 92253 Telephone: (7R6)X64-4707 (sig ure) (date) JEnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:4 of 13 Certificate of Compliance: Residential (Addendum) CF -1 R Coronel Enterprises Inc. 4/20/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System 'Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. An Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R. Plan Field The HVAC System "Res HVAC' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 04/20/05 08:52:16 Run Code: 1114012336 EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X not apply to exterior mass walls). E]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no a greater than 2.0 perm/inch. a§ 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiftration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX] 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2, Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. 'b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. IA-] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 5970 Job Number: 11823 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R Coronel Enterprises Inc. 4/20/2005 Project Title Date Taos -All Orientations La Quinta Project Address Building Permit # South West Concepts (760) 564-4707 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 3.65 Facing North Margin Ll Facing East Margin -0 nnnr 20 0 387 90 Wall 519 0.059 90 90 Wall 341 0.059 180 90 Facing South Margin ❑ ❑ Facing West Margin 1.56 2.09 1.59 2.05 2.03 1.62 2.01 1.64 Space Cooling 38.67 36.51 2.16 35.03 3.63 34.22 4.44 32.99 5.67 Domestic Hot Water 13.83 1 12.05 1.78 12.05 1.78 12.05 1.78 12.05 1.78 50.12 6.02 48.68 7.461 1 48.31 7.84 1 47.05 9.09 Totals 56.14 3�11��]V[tZ��]►�il,�l� This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 1,823 ft Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 14.3% Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,230 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,823 ft2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area $es HVAC.' 1 A23 18 9�n 1 nn _('ondltioned Setback -2 -n/ OPAQUE SURFACES 5olar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Rnnf 1 823 0.028 _� 99 Wall 115 0.059 go ®❑ Ll R-38 Roof (R 3$ 5,.14 1 1st Flnnr 7nna R-13 Wall w/1" FPS - 1St Flnnr 7onp -0 nnnr 20 0 387 90 Wall 519 0.059 90 90 Wall 341 0.059 180 90 ®®®❑ ❑ ❑ smrl w..d nr,.r 1 St Floor 7one R-13 Wall w/1" FPS 1st Flnor 7one R-13 Wall w/1" FPS 1 qt Flnnr 7nnp _ Wall 444 0.059 270 90_ R-11 Wall w/1" FPS 1st Floor 7one a ❑❑ ❑❑°❑ F-1 --1 ❑❑❑❑ E-1 El Run Initiation Tmmeh 04/20105 08*52*16 Run Codes 1114012336 3.1 By EnergySoft User Number: 5970 1823 Page:8 of 13 Comauter Method Summary (Part 2 of 3) C -2R Coronel Enterprises Inc. 4/20/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Twe Area Factor SHGC Azm. Tilt Comments -1_ Window Front (North) 40.0 0.480 0 58 _�_ qQ Dr1Bbl . Metal Tinted I ow P 1 st Flnor Znne 2 Window Front (North) 12.0 0.350 0.59 0 90 Double Metal Tinted Low a 1st Floor Zone 3 Window Left (East) 25.0 0.500 0.58 90 90 Double Metal Tinted Low a 1st Floor Zone 4 Window Left (East) 9.0 0.870 0.70 90 90 Double Metal Clear Default 1st Floor Zone 5 Window Left (East) 24.0 0.500 0.58 90 90 Double Metal Tinted Low e 1 st Floor Zone 6 Window Left (East) 33.4 0.480 0.58 90 _ 90 Double Metal Tinted Low a 1st Floor Zone Z Window Left- ast) 10.0 0,35Q 0.59 90 _90 Double Metal Tinted Low a 1st Floor Zone 8 Window Rear (South) 33.4 0.480 0.58 180 90 Double Metal Tinted Low e 1 st Floor Zone _q_ Window Rear (South) 10.0 0.350 0.59 180 90 Rouble Metal Tinted Low a 1st Floor Zone 10 Window Rear -(South) 16.0 0.350 0.59 180 90 Double Metal Tinted Low e 1 st Floor Zone 11 Window Right (West) 12.0 0.570 0.67 270 90 Double NonMtl Clear Default 1st Floor Zone 12 Window Right (West) 16.0 0.500 0.58 270 90 Double Metal Tinted Low e 1 st Floor Zone _1a Window Right (West) 4.0 0.500 0.58 270 -90 Double Metal Tinted Low a 1st Floor Zone 14 Window Right (West) 16.0 0.500 0.58 270 90 Double Metal Tinted Low e 1 st Floor Zone INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.6 6.0 1.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 6.0 1.0 0.1 2.0 2.0 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 Run Iriffiatoon Tomee 04/20105 08:52616 Run Codev 1114012336 EnerovPro 3.1 By EneravSoft User Number: 5970 Job Number: 1823 Page:9 of 13 N Computer Method Summary. (Part 3 of 3) C -2R Coronel Enterprises Inc. 4/20/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Frame Wall. Stucco 115 033 —21 0_47 R-14 Wall w/1" FPS —2 1st Floor Znne / Exterinr Macc PERIMETER LOSSES F2 Insulation Factor R -Val. Dept 0 76 0.0 --d HVAC SYSTEMS Location / Comments 1st Floor Zone Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 89%AFUE Ducts in Attic 4.2 Setback Res HVAC Hydronic Piping Pipe Pipe Insul. . System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Res HVAC WATER HEATING SYSTEMS Ratedl Tank Energy Fact' 1 Tank insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 1 43,000 50 0.60 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 04/20/05 08:52:16 Run Code: 1114012336 EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page;10 of 13 Computer Method Summary (Addendum) C -2R Coronel Enterprises Inc. 4/20/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on ine aaequacy or the special tusuricanon ana aocumentation suominea. I Plan Field The HVAC System "Res HVAC" includes credit for a Radiant Barrier installed oer Section 8.13 of the Residential Manual. lAn Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a Corm GF -6R. Plan Field The HVAC System "Res HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Res HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page: 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Coronel Enterprises Inc. 4/20/2005 SYSTEM NAME FLOOR AREA Res HVAC 1,823 Number of Systems 1 Heating System Output per System 112,000 Total Output (Btuh) 112,000 Output (Btuh/sgft) 61.4 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 31.8 Total Output (sgft/Ton) 377.2 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.10 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYST 26.0 of Outside Air 0 cfm 69.3 of 69.3 of 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,365 33,415 -54 762 28,370 0 1,671 1,418 0 0 0 0 0 0 0 0 0 1,6711 1,418 136,756 54 31207 CARRIER 38BRC06034/35 45,068 3,530 112,000 Total Adjusted System Output45,068 3,530 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am -earn Temoeratures at Time of Heatina Peak) 105.0 of Supply Fan Heating Coil 2000 cfm Return Air Ducts Supply Air Ducts 104.3 of ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 115.0 / 73.5 of 78.8 / 62.3 of 78.8 / 62.3 of 55.0 / 53.5 of Supply Air Ducts Outside Air 0; -I 0 cfm Supply Fan Cooling Coil 55.8 / 53.9 of 2000 cfm 40.5% R.H. ROOMS 78.0 / 62.0 of 78.8/62.3 of I Return Air Ducts EneravPro 3.1 By EnerovSoft User Number: 5970 Job Number: 1823 Page: 12 of 13 1 ROOM LOAD SUMMARY PROJECT NAME Coronel Enterprises Inc. DATE 4/20/2005 SYSTEM NAME Res HVAC FLOOR AREA 1,823 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT1st SENSIBLE LATENT CFM SENSIBLE 1st Floor Zone Floor - 1 1,365 33,415 -541 r1,365 33,415 -541 762 28,370 PAGE TOTAL ' 1 1,365 33,415 -541 762 28,370 TOTAL 1 1,365 33,415 -541 762 28,370 EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page: 13 of 13