05-1553 (SFD)0
.lbw"" rgr•� A;
BUILDING & SAFETY DEPARTMENT
D. Sw
ox 1504 (760),777-7012
ISE78- CALLE TAMPICO FAX (760) 777-7011
,UI TA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
c�NANc of BUILDING PERMIT
pplication Number 05-00001553 Date 4/27/05
Property Address . . . 53330 AVENIDA HERRERA
APN: 774-084-004-21 -000000-
Application-description DWELLING - SINGLE FAMILY DETACHED.
Property Zoning . . . . . . .COVE RESIDENTIAL
Application valuation . . . 1.13704
Owner Contractor
--------------------------------- ---------------------------------
CORONEL ENTERPRISES 'CORONEL CONSTRUCTION
P 0 BOX 389 P.O. BOX 389
LA QUINTA, CA 92253 LA QUINTA, CA 92247
(760)564-4604
WCC: STATE FUND
WC: 174445305 01/01/06
CSLB: 634981 01/31/06
CCC: B -C13
Other struct info . . . . . CODE EDITION 2001 CBC
# BEDROOMS 3.00
FIRE SPRINKLERS NO
GARAGE SQ FTG 481.00
NUMBER OF UNITS 1.00
1ST FLOOR SQUARE FOOTAGE 1823.00
---------------------------------------------------------------------- - - - - --
OW
P.O. Box 1504• �� VOICE (760) 777-7012
78-495 CALLS TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 4.4 QINSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
E;r'J
Application Number:
Applicant:
Applicant's Mailing Address:
0 04
EWA
D' e �-.S- ar _dam
t `
Architect or Engineer _� �7. _IFII
Architect or Engineer's Address:
I WI=
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
iyaffirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
and my, license is in full force and effect. .-7—
. Class (Z�� 7, S(1 — Lic! ens.
OWNER -BUILDER DECLARATION
1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the'following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. BA P.C. for this reason
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
�� issued. My WQfkers' ompensafion_insurance carrier and policy number,are:
�CarriT err �h �k � r–� I Policy Number"
— I certify that, in the performance of'the-work`f& which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with tpgse provisions. /-- _
-v5
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lenders Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2.. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the abov information is correct. I agree to comp ith all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this cou ty enter pon the ab - entioned ro erty for inspection purposes.
Date S-7_,��c/5 Sigq ture_(Applica-t.Age t):
--------------------------------------------------------------------------
--
Application Number . . . . . 05-00001553
----------------------------------------------------------------------------
P
Permit . . . . . . BUILDING PERMIT
Additional desc
Permit Fee . . . . 688.50
Issue Date . . . .
Plan Check Fee 447.53
Valuation . . . . 113704
Expiration
Date
10/24/05
Qty Unit Charge
Per
Extension .
BASE
FEE
639.50
14.00
----------------------------------------------------------------------------
3.5000
THOU BLDG
100,001-500,000
49.00
Permit .
. . . . .
MECHANICAL
Additional
desc . .
Permit Fee
. . . .
59.00
Plan Check Fee
14.75
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
.10/24/05
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00
9.0000
EA MECH
FURNACE <=100K
9.00
1.00
9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
3.00
6.5000
EA MECH
VENT FAN
19.50
1.00
----------------------------------------------------------------------------
6.5000
EA MECH
EXHAUST HOOD
6.50
Permit .
. . . . .
ELEC-NEW RESIDENTIAL
Additional
desc
Permit Fee
. . . .
103.43
Plan Check Fee
25.86
Issue Date
. . .
Valuation
0
Expiration
Date
10/24/05
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1823.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
63.81
481.00
.0200"
ELEC
GARAGE OR NON-RESIDENTIAL
9.62
1.00
----------------------------------------------------------------------------
15.0000
EA ELEC
TEMPORARY POWER POLE
15.00
Permit .
. . . . .
PLUMBING
Additional
desc . .
Permit Fee
135.00
Plan Check Fee
33.75
Issue Date
Valuation . . . .
0
Expiration
Date
10/24/05
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
11.00
6.0000
EA PLB
FIXTURE
66.00
1.00
15.0000
EA PLB
BUILDING SEWER
15.00
1.00
7.5000
EA PLB
WATER HEATER/VENT
7.50
1.00
3.0000
EA PLB
WATER INST/ALT/REP
3.00
1.00
9.0000
EA PLB
LAWN SPRINKLER SYSTEM
9.00
6.00
.7500
EA PLB
GAS PIPE >=5
4.50
1.00
-----------------------------------------------------------------------------
15.0000
EA PLB
GAS METER
15.00
Permit .
. . . . .
GRADING PERMIT
Additional
desc
Permit Fee
. . . .
15.00
Plan Check Fee
.00
Issue Date
. . . .
Valuation . . . .
0
----------------------------------------------------------------------------
Application Number .
. . . . 05-00001553
521.89
----------------------------------------------------------------------------
Permit . . . . . .
GRADING PERMIT
.00
Expiration Date
10/24/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
1823 SF. SFD PERMIT DOES NOT INCLUDE
BLOCK WALL, POOL/SPA
OR DRIVEWAY
APPROACH
----------------------------------------------------------------------------
Other Fees . . . . .
. . . . ART IN PUBLIC PLACES -RES
20.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
44.75
DIF FIRE PROTECTION -RES
97.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC'- RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
11.37
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
------------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Charged Paid
1000.93
.00
521.89
250.00
2481.12
.00
4003.94
250.00
Credited Due
.00
1000.93
.00
271.89
.00
2481.12
.00
3753.94
•4 4v
P.O. BOX 1504 APPLICATION ONLY
Building t�-� _� , ^ �\ 78-495CALLCALIFORNIATAMPIO
Address _ 1 l�\.i �- � c f e'C �. LA OUINTA, IORNIA 92253
4� A
Mailing. -
Address
City Zip Tel.
Contractors—
ress
State Lic. • City
& Classif. yGj (I Lic. N �1
Arch., Engr., d�
Designer
Address Tel.
City Zip State
Lic. If
r LICENSED CONTRACTOR'S DECLARATION
reby affirm that I am licensed under provisions of Chapter 9 (commencing with Se tlo
7 ) of Division 3 of jaa Business and Professions Code, and my license is in full for a d
NM -BUILDER DECLARATION
I here ffir a exempt from the Contractors License Law for the f lowing
reason: (Sec 031.5,Busin s and Professions Code: Any city or county which r quires a
permit to cons cf, alter, i rove, demolish, or repair any structure, prior to 'its !ss once also
requires the ap ' ant for s h permit to file a signed statement that he is licensed ursuant to
the provisions of a Cc actor's License Law, Chapter 9 (commencing with Sect n 7000) of
Division 3 0! the Btu s antl Pro/essions Code, or that. he is exempt therefrom, and the basis
!or the alleged exAtnpfion. Any violation o/ Section 7031.5 by any applica lot a permit
subjects the applicant o a civil penalty of not more than live hundred dollars ($500).
!: I, as owner of the property, or my employees with wages as their sole c Inpensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 044, Buisness and
Professions Code: The Contractor's License Law does not apply to an ow er of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such Improveme@nts are not intended or offered for sale. If however, the building
or improvement is sold wffh1h,pne year o! completion, the owner -build r will have the burden
o! proving that he did not build or\mprove for the purpose of sale.)
II I, as owner of the property, am exclusively contracting with lic nsed contractors to con-
struct the project. (Sec. 7044, \Business and Professions Code: T e Contractor's License Law
does not apply to an owner of property who builds or improves fh reon, and who contracts for
such projects with a contractor(s) lice Sed pursuant to the Contractor' License Law.)
I'! I am exempt under Sec. � B. & P.C. for this re on
Date Owner
WORKERS' COMPENSATIONECLARATION
I hereby affirm that I have a certificate of co sent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified co thereof. (Sec. 3800, Labor Code.)
Policy No. Company
[l Copy is filed with the city. ❑ Certified c y is hereby furnished.
CERTIFICATE OF EMV,TION FROM
WORKERS' COMPE SATION INSURANCE
(This section need not be completed if the ermif is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of t work. for which this permit is issued, I shall not
employ any person in any manner so a to become subject to the Workers' Compensation
Laws of California. \\
Date Owner
NOTICE TO APPLICANT: If, after king this Certificate of\Exempfion you should become
subject to the Workers' Compens ion provisions of the Labor Code, you must forthwith
comply with such provisions or this pQ if shall be deemed revokedA
NSTRUCTION LENDING AGENCY
I hereby affirm that th a is a construction lending agency for he performance of the
work for which this permit s issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building rIn t when properly filled out, signed and validate and is subject to
expiration if work the eunder is suspended for 180 days.
I certify that 1 hav read this application and state that the above inform tion is correct.
I agree to comply ith all city and county ordinances and state laws relatt to building
construction, an hereby authorize representatives -of this city to enter he above.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING: TYPE -CONST. OCC. GRP.
A.P. Number
—7"-A `V-A —00--i
Legal Description \—A _,�L_�
Project Description S • -
1
Sq. Ft. \i� -�
Size
New �' Add ❑
imated Valuation
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
G;\.
No. l
StnriPs
Alter ❑ Repair
ZONE:
BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
INSPECTOR
Issued by:
Date Permit
Validated by:
Validation:
WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE
City Zip Permit #
Tract # Study Area
Type Single Family Residence No. of Units 1
Lot # No. Street
.Unit 1 53330 Avenida Herrera
Unit 2
Unit 3
Unit 4
Unit 5
S.F. Lot # No.
1823 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Comments Certs #27231 and 27232 used for #349014 in the amount of $7,474.88.
Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 1,823 S.F. or $4,083.52 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Rabobank - Ish Coronel Check No. 349014
Name on the check Telephone
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by S Mc Ivrey Payment Reed
$4,083.52 Over/Under
Signature r7l
NOTICE: Pursuant to Government Code Section 66020(d)(1), this\4,41 serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting
APR -26-2005 TUE 08:56 AM Coronel Construction
RECORDING REQUESTED BY.
F� fidelity National Title Company
EECioW No, 9850 -KC
TRIe Order No_ gajtmS! 1�1
When Recorded (Mail Document
and Tax Statement To:
Coronel Enterprises, Inc.
51185 Avenida Villa
La Quinta, CA 92253
FAX No. 760 564 4202 P-012
000 = 2005_0228196
03/23/2005 08:00A Fee:10.00
Page 1 of 2 Doc T Tax Paid
Recorded in Official Records
County of Riverside
L.arry W. Ward
Assessor, County Clerk & Recorder
ArjN: / /,+-vo,+-uu,4-u uzu-u 1 z) GRANT DEEU
or"''` Aovvc 1 n10 L11ML r ,.. .� .....�.,
D
The undersigned grantor(s) declare(s) 9
Documentary transfer tax is $181.50 S�
[ X I computed on full value of property conveyed, or
I computed on full value less value of liens or encumbrances remaining at time of sale,
) City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, James E. Burke and 'vaientitia
I_ Burke, Trustees, in trust, pursuant to the terms of the James E. Burke and Valentina I. Burke Family Trust, dated
December 15, 1989, and any amendments thereto
-hereby GRANT(S) to Coronel Enterprises, Inc., a California Corporation
the following described real property in the City of La Quinta
County of Riverside, State of California:
Lot 21, Block 226, SANTA CARMELITA AT VALE LA QUINTA,, UNIT NO. 21, COUNTY OF RIVERSIDE, STATE OF
CALIFORNIA, AS PER MAP RECORDED IN BOOK 20, PAGE 22 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE
COUNTY RECORDER OF SAID COUNTY.
DATED: February 25, 2005
STATE OF CALIFORNIA
COUNTY OF
ON before me,
lox
personally appeared
Al 6
personally known to me (or proved to me on the basis
o satin actory evid--an—cel to be the person(s) whose
names) ,Pg/are subscribed to the within instrument and
acknowledged to me that Pit/sfte/they executed the
same in bars/Ker/their authorized capacity(ies), and that
by Vw/Itr/their signatures) on the instrument the
person(s), or the entity upon behalf of which the
person(s) acted, executed the instrument.
Wtne4s my hand and official seal.
Signature
James E. Burke and Valentina I. Burke, Trustees, in
trust, pursuant to the terms of the James E. Burke
and Valentina f. Burke Family Trust, dated December
15, 1983, and any amendments the
/01,6mes Burke, Trustee
Valentina 1. 1311e, Trustee
MAIL TAX STATEMENTS AS DIRECTED ABOVE
FD -213 (Rev 7196) GRANT DEED
JANE F. BU129DD
d
Commission 1 5767
��..'�.
Not ry ubllc • Cotornia b
Los Angeles MarCounty
29
Con'u'n. ExpifF�s Mar 29.2.!X75
nfrwgpMy
MAIL TAX STATEMENTS AS DIRECTED ABOVE
FD -213 (Rev 7196) GRANT DEED
Certificate of Occupancy
4
G� OF'TBuilding & Safety Department
This Certifica&F is issued pursuant to the requirements of Section 109 of the California Buildh g
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 53-330 AVENIDA HERRERA
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-1553
Occupancy Group: R3 Type of Construction: VN Land Use Zone: RC
CORONEL CONSTRUCTION Address: P.O. BOX 389
City, ST, ZIP: LA QUINTA, CA 92247
By: KIRK KIRKLAND
Date: MARCH 6, 2006
Building Official `
POST IN A CONSPICUOUS PLACE
I TITLE 24 REPORT I
Title 24 Report for:
Coronel Enterprises Inc.
Taos -All Orientations
La Quinta, CA 92253
Project Designer:
Stephen R. Nieto
78-120 Calle Estado Ste. 206
La Quinta, CA 92253
760-564-4707
Report Prepared By:
Stephen R. Nieto
South West Concepts
78120 Calle Estado, Suite 206
La Quinta, CA 92253
(760) 564-4707
Job Number:
1823
Date:
4/20/2005
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE4ZA -05 BY S_
O F'G'lcc
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: 1823 User Number: 5970
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
1
2
3
6
8
12
13
EnergyPro 3.1 By EnergySoft Job Number: 1823 User Number: 5970
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
Taos -All Orientations La Quinta
Project Address Building Permit #
South West Concepts (760) 564-4707 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 1,823 ft2 Average Ceiling Height: 10.0 ft
Total Conditioned Slab Area: 1}823 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
Const.
Component Frame Assembly Location/Comments
Tvne Tvpe U -Value (attic, garage, typical, etc.
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
R-13 Wall w/1" EPS
Wood
0.059
Exterior Wall
Solid Wood Door
Wood
0.387
Exterior Door
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FENESTRATION
Shading Devices
Type Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
40.0
0.48
0.58
Bug Screen
Q
❑
❑ Q
Front
12.0
0.35
0.59
Bug Screen
Q
❑
❑ a
Left
49.0
0.50
0.58
Bug Screen
❑
0
❑ Q
Left
9.0
0.87
0.70
Bug Screen
❑
Q
❑ Q
Left
33.4
0.48
0.58
Bug Screen
❑
Q
❑ Q
Left
10.0
0.35
0.59
Bug Screen
❑
0
❑ Q
Rear
33.4
0.48
0.58
Bug Screen
❑
0
❑ o
Rear
26.0
0.35
0.59
Bug Screen
❑
0
❑ Q
Right
12.0
0.57
0.67
Bug Screen
❑
El
❑ Q
Right
36.0
0.50
0.58
Bug Screen
❑
Q
❑ 0
❑
❑
❑ ❑
Run Initiation Time: 04/20/05 08:52:16 Run
Code: 1114012336
Ener Pro 3.1 By Ener Soft
User Number: 5970
Job Number: 1823
Pa e:3 of 13
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Coronel Enterprises Inc. •4/20/2005
Project Title Date `
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Central Furnace 89% AFUE Ducts in Attic 4-2 Setback Res HVAC
Cooling Equipment Minimum
Duct
Type (air conditioner, Efficiency
Location
Duct
Thermostat Location /
heat pump, evap. cooling) (SEER)
(attic, etc.)
R -Value
Type
Comments
Split Air Conditioner 12.0 SEER
Ducts in Attic
4.2
Sethank
Res HVAC
WATER HEATING SYSTEMS
Water Heater Water Heater
Distribution
Rated 1
# in Input
Tank
Cap.
Energy Fact! 1 External
or Recovery Standby Tank Insul.
System Name Type
Type
Syst. Btu/hr
(gal)
Efficiency Loss (%) R -Value
A-0- SMIIH FPS -50-224 Small Gas
Standard
1 43 000
50
060 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name
Title/Firm: Stephen R. Nieto
Address: 78-120 Calle Estado Ste. 206
a Quinta CA 92253
Telephon . 7 0-564-4707
Lic.%w
#: z
y zd aJ-
(sig ure) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name: Steohen R. Nieto
Title/Firm: South West Concepts
Address: 78120 Calle Estado, Suite 206
La Qui to CA 92253
Telephone: (7R6)X64-4707
(sig ure) (date)
JEnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:4 of 13
Certificate of Compliance: Residential (Addendum) CF -1 R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The HVAC System 'Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
An Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R.
Plan
Field
The HVAC System "Res HVAC' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 04/20/05 08:52:16 Run Code: 1114012336
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:5 of 13
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
❑X 1150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
X not apply to exterior mass walls).
E]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
a
greater than 2.0 perm/inch.
a§ 118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiftration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§ 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
❑X § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
FX §150(j): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page:6 of 13
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
FX] 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2, Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
'b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
IA-] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 5970 Job Number: 11823 Page:7 of 13
Computer Method Summary (Part 1 of 3) C -2R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
Taos -All Orientations La Quinta
Project Address Building Permit #
South West Concepts (760) 564-4707
Documentation Author Telephone Plan Check/Date
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer) Cimate Zone
Source Energy Standard
Use (kBtu/sf-yr) Design
Space Heating 3.65
Facing
North Margin
Ll
Facing
East Margin
-0
nnnr 20 0 387 90
Wall 519 0.059 90 90
Wall 341 0.059 180 90
Facing
South Margin
❑
❑
Facing
West Margin
1.56 2.09
1.59 2.05
2.03 1.62
2.01 1.64
Space Cooling 38.67
36.51 2.16
35.03 3.63
34.22 4.44
32.99 5.67
Domestic Hot Water 13.83
1 12.05 1.78
12.05 1.78
12.05 1.78
12.05 1.78
50.12 6.02
48.68 7.461
1 48.31 7.84
1 47.05 9.09
Totals 56.14
3�11��]V[tZ��]►�il,�l�
This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations.
Total Conditioned Floor Area: 1,823 ft
Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Building Front Orientation: All Four Orientations Total Fenestration Area: 14.3%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,230 ft 3
Number of Stories: 1 Total Conditioned Slab Area: 1,823 ft2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
$es HVAC.' 1 A23 18 9�n 1 nn _('ondltioned Setback -2 -n/
OPAQUE SURFACES 5olar
Act. Gains
Type Area U -Val. Azm. Tilt Y / N Form 3 Reference
Location / Comments
Rnnf 1 823 0.028 _� 99
Wall 115 0.059 go
®❑
Ll
R-38 Roof (R 3$ 5,.14 1 1st Flnnr 7nna
R-13 Wall w/1" FPS - 1St Flnnr 7onp
-0
nnnr 20 0 387 90
Wall 519 0.059 90 90
Wall 341 0.059 180 90
®®®❑
❑
❑
smrl w..d nr,.r 1 St Floor 7one
R-13 Wall w/1" FPS 1st Flnor 7one
R-13 Wall w/1" FPS 1 qt Flnnr 7nnp
_
Wall 444 0.059 270 90_
R-11 Wall w/1" FPS 1st Floor 7one
a
❑❑
❑❑°❑
F-1
--1
❑❑❑❑
E-1
El
Run Initiation Tmmeh 04/20105 08*52*16 Run Codes 1114012336
3.1 By EnergySoft User Number: 5970 1823 Page:8 of 13
Comauter Method Summary (Part 2 of 3) C -2R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
FENESTRATION SURFACES
U- Act. Glazing Type Location/
# Twe Area Factor SHGC Azm. Tilt Comments
-1_
Window Front
(North)
40.0
0.480
0 58
_�_
qQ Dr1Bbl . Metal Tinted I ow P
1 st Flnor Znne
2
Window Front
(North)
12.0
0.350
0.59
0
90 Double Metal Tinted Low a
1st Floor Zone
3
Window Left
(East)
25.0
0.500
0.58
90
90 Double Metal Tinted Low a
1st Floor Zone
4
Window Left
(East)
9.0
0.870
0.70
90
90 Double Metal Clear Default
1st Floor Zone
5
Window Left
(East)
24.0
0.500
0.58
90
90 Double Metal Tinted Low e
1 st Floor Zone
6
Window Left
(East)
33.4
0.480
0.58
90
_ 90 Double Metal Tinted Low a
1st Floor Zone
Z
Window Left-
ast)
10.0
0,35Q
0.59
90
_90 Double Metal Tinted Low a
1st Floor Zone
8
Window Rear
(South)
33.4
0.480
0.58
180
90 Double Metal Tinted Low e
1 st Floor Zone
_q_
Window Rear
(South)
10.0
0.350
0.59
180
90 Rouble Metal Tinted Low a
1st Floor Zone
10
Window Rear
-(South)
16.0
0.350
0.59
180
90 Double Metal Tinted Low e
1 st Floor Zone
11
Window Right
(West)
12.0
0.570
0.67
270
90 Double NonMtl Clear Default
1st Floor Zone
12
Window Right
(West)
16.0
0.500
0.58
270
90 Double Metal Tinted Low e
1 st Floor Zone
_1a
Window Right
(West)
4.0
0.500
0.58
270
-90 Double Metal Tinted Low a
1st Floor Zone
14
Window Right
(West)
16.0
0.500
0.58
270
90 Double Metal Tinted Low e
1 st Floor Zone
INTERIOR AND EXTERIOR SHADING
window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
6.6
6.0
1.0
0.1 2.0 2.0
2
Bug Screen
0.76
2.0
6.0
1.0
0.1 2.0 2.0
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
Run Iriffiatoon
Tomee
04/20105
08:52616
Run Codev 1114012336
EnerovPro 3.1
By EneravSoft
User Number: 5970
Job Number: 1823
Page:9 of 13
N
Computer Method Summary. (Part 3 of 3) C -2R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Frame Wall. Stucco 115 033 —21 0_47 R-14 Wall w/1" FPS —2 1st Floor Znne / Exterinr Macc
PERIMETER LOSSES
F2 Insulation
Factor R -Val. Dept
0 76 0.0 --d
HVAC SYSTEMS
Location / Comments
1st Floor Zone
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Central Furnace 89%AFUE Ducts in Attic 4.2 Setback
Res HVAC
Hydronic Piping Pipe Pipe Insul. .
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat
Location /
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type
Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback
Res HVAC
WATER HEATING SYSTEMS Ratedl Tank
Energy Fact' 1 Tank insul.
Water Heater Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
A.O. SMITH FPS -50-224 Small Gas Standard 1 43,000 50
0.60 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby
Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 04/20/05 08:52:16 Run Code: 1114012336
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page;10 of 13
Computer Method Summary (Addendum) C -2R
Coronel Enterprises Inc. 4/20/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
)asea on ine aaequacy or the special tusuricanon ana aocumentation suominea. I Plan Field
The HVAC System "Res HVAC" includes credit for a Radiant Barrier installed oer Section 8.13 of the Residential Manual.
lAn Air Retarding Wrap must be installed per the manufacturer's specifications that must comply with ASTM E1677-95.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a Corm GF -6R.
Plan
Field
The HVAC System "Res HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Res HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page: 11 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Coronel Enterprises Inc. 4/20/2005
SYSTEM NAME FLOOR AREA
Res HVAC 1,823
Number of Systems
1
Heating System
Output per System
112,000
Total Output (Btuh)
112,000
Output (Btuh/sgft)
61.4
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
Total Output (Btuh/sgft)
31.8
Total Output (sgft/Ton)
377.2
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.10
Airflow (cfm/Ton)
413.8
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
EATING SYST
26.0 of
Outside Air
0 cfm
69.3 of
69.3 of 69.3 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
1,365
33,415
-54
762
28,370
0
1,671
1,418
0
0
0
0
0
0
0
0
0
1,6711
1,418
136,756 54 31207
CARRIER 38BRC06034/35 45,068 3,530 112,000
Total Adjusted System Output45,068 3,530 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
-earn Temoeratures at Time of Heatina Peak)
105.0 of
Supply Fan Heating Coil
2000 cfm
Return Air Ducts
Supply Air Ducts
104.3 of
ROOMS
70.0 of
I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak
115.0 / 73.5 of 78.8 / 62.3 of 78.8 / 62.3 of 55.0 / 53.5 of
Supply Air Ducts
Outside Air 0;
-I
0 cfm Supply Fan Cooling Coil 55.8 / 53.9 of
2000 cfm 40.5% R.H. ROOMS
78.0 / 62.0 of
78.8/62.3 of I
Return Air Ducts
EneravPro 3.1 By EnerovSoft User Number: 5970 Job Number: 1823 Page: 12 of 13 1
ROOM LOAD SUMMARY
PROJECT NAME
Coronel Enterprises Inc.
DATE
4/20/2005
SYSTEM NAME
Res HVAC
FLOOR AREA
1,823
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT1st
SENSIBLE
LATENT
CFM
SENSIBLE
1st Floor Zone
Floor -
1
1,365
33,415
-541
r1,365
33,415
-541
762
28,370
PAGE TOTAL ' 1 1,365 33,415 -541 762 28,370
TOTAL 1 1,365 33,415 -541 762 28,370
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 1823 Page: 13 of 13