10165 (SFD)f 441W O.4% N o . 10165 Building 78-105 CALLE ESTADO . Address 53-440 Herrera LA QUINTA, CALIFORNIA 92253 Owner . )( G 1/7 Harry Chaplin Mailing Address P. 0. Bow 204 BUILDING: TYPE CONST. A.P. Number 774-084-011 Legal Description Project Description OCC: GRP. Let 14 Block 226 5FD i City P.D. Zjp 92261 Tel. Contractor Sun Country Construction Address 78365 F; igl way ? l l #166 City Zip Tel.: Tia Q3uinta 92253 564-4690 State Lic. City & Classif. 358739 Lic. # 1787 Sq. Ft. Size 1512 No. No. Dw. Stories Units Arch., Engr., Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. Permit does not include block walls or nool City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing wittf Section 7000) of Division 3 of theBusin ef�$ys en/d•Prorof "scions Code, and my license is in 7%111 forcee�fAnd effect. &.44R., ✓ 9�1 SA (i r11 •SIGNATURE � � '" \"� e� 1 f j' DATE ' OWN ER-BOU MDER DECLARATION I hereby affirm that I am exempt from the Contractor's License law for the following reason: (Sec. 7031.5,Suslness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of properly y -who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale. If, however, the building, or Improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) Estimated Valuation 91,002.80 PERMIT ' AMOUNT Plan Chk. Dep. 250.00 Plan Chk. Bal. 2 2.15 Const. rt A - 603 3 . 5 0 Mech. 5 ri . 50 Electrical �'� 6 Plumbing 1 1 {� O I, as owner of the property, am exclusively contracting with licensed contractors to com struct -the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property -who builds or improves thereon, and, who contracts for - such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) , O I am exempt under Sec. B. & P.C. for this reason S.M.I. . 9. 20 Grading 20 .00• Driveway Enc. 20.00 Date Owner Infrastructure 1956.26 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company R%Copy is.filed with the city. O Certified copy is hereby furnished. TOTAL 3443.65 3193.55 CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars (8100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation' Laws of California. REMARKS i 1 i G 1 tis €i aa , Al11 }.k 111 � ..}+��'1, A -�1+.. #, •. v •xrewr x I 1ae m rrc„ r "N Date Owner NOTICE TO APPLICANT: If, after making this .Certificate of .Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. .ZONE BY: ' Minimum Setback Distances: Front.Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil code.)Side Side Street Setback from Center Line Setback from Property Line Lender's Name i Lender's Address FINAL DATE Issued by: Validated by: INSPECTOR Date Permit ' This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct.. ' i I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. 4' Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS SLAB GRADE /� 3/ 2ND FL SO. FT. BONDING YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. GAS (ROUGH) DRAINAGE PIPING WALL SO. FT. OTHER APPJEOUIP. DRINKING FOUNTAIN. SO FT ® TEMP. POLE O URINAL ESTIMATED CONSTRUCTION VALUATION $ GROUT WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. FLOOR DRAIN MECHANICAL FEES WATER SYSTEM WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FRAMING (% %/?/ GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM REMARKS: KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1Vi c SEWAGE DISPOSAL SO.FT.GAR ® V4c HOUSE SEWER MESH GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK 3� GROUND PLUMBING 2fJ' UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE /� 3/ ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER n ROUGH WIRING. DUCTWORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL ® �� GAS (FINAL) TEMP. POLE O GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL INSP. GRADING -cu. yd. $ plus x$ =$ LUMBER GR. FRAMING (% %/?/ FINAL INSP. ROOFING � ////7 /il 7 7 REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUNDlei FINISH GRADING FINAL INSPECTION- �0 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL i� l 4 •� P.O. BOX 150440U APPLICATION ONLY '134jilding 78-105 CALLE ESTADO Address LA QUINTA, CALIFORNIA 92253Owner A &-intBUILDING: TYPE CONST. OCC. GRP: Mailing Address City /� Zip Tel. �di/elf(tel Address / ZID_ _ , I Tel.. State Lic. City & Classif. ����?i Lic. # 7 .... _..., _.... -1 Designer Address CityI Zip I State Lic. # LICENSED CONT X OR' DECLARATION I hereby affirm that I am tic used un r p 6 s'p Chapter 9 (commencing with Section effect. of Division 3 f t B si ess r6fesa e�-a\ y license is in full force and effect. /X' SIGNATURE DATE OWNER -BUILDER .ECI RATION -I'hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a - permit to construct, alter, Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any -.applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 0 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Dale _ Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any Person in any manner so as to become subject to the Workers' Compensation Laws of California. Date - Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all ci�tyy,,and county ordinances and state laws relating to building construction, and hereby au brize representatives sof this city to enter the above-. mentioned property for inspection purposes. Signature of appl .Mailing Address_ City, State, Zip- / '` BUILDING DIVISION A.P. Number 77 q/_ Legal Description /,.,7-/.— ,7 l Project Description Sq. Ft. Z o. No. Dw. Size Stories. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. —� Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. nfrastructure .�+ TOTAL ` 2-61 REMARKS 005401 40 4064 40-45-94 10 oa_v_ .. i0 CASH i TOTAL i 275.00 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR i Issued by: Date ` Permit 1' Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SQ. FT. ® $ UNITS SLAB GRADE 2ND FL. SQ. FT. BONDING YARD SPKLR SYSTEM STORAGE TANK MOBILEHOME SVC. BAR SINK POR. SO. FT. ® DUCT WORK ROCK STORAGE GAR. SO. FT. ® POWER OUTLET ROOF DRAINS HEATING (FINAL) OTHER APPJEOUIP. DRAINAGE PIPING CAR P. SD. FT. TEMP. POLE WALL SO. FT. GROUT DRINKING FOUNTAIN SQ FT ® FINAL INSP. URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER SYSTEM WATER PIPING NOTE: Not to be used as property tax valuation =$ FLOOR DRAIN MECHANICAL FEES FINAL INSP. WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB GAR. FIREWALL SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4cVELECT SEWAGE DISPOSAL MESH SO.FT.GAR ® 3/aHOUSE SEWER INSULATION/SOUND GAS PIPING PERMIT FEE FINISH GRADING PERMIT FEEPERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE IPL.CK.FEE CONST. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT t 82-879 Highway111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated ; (619) 347-8631 Date 10/28/91 No. 110952 Owner Name Type of Permit Harry Chaplin No. 53440 Street Herrera city La Quinta zip 92253 La Quinta Permit # 110165 Log # Study Area 112 APN # I Tract # I Lot # E� Square Footage 11512 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.58 X 11.512 or $ 2,388.96 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Sun Country Construction Telephone Name on the check'- g� James E. Lively Assistant Superintendent, Business Services Fee collected /exempted by Vickie J. Durrett Signature. Payment Received', , Check No. 1041 Collector. Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting COACHELLA VALLEY WATER DISTRICT CASH RECEIPT DETAIL Received From: Address: Account No. Lot(s) Service Address Meter(s) AService(s) 1- / ❑ Backflow(s) ❑ House Laterals) ❑ DetectorCheck(s) ❑ Meter Surcharge ASanitation Capacity Charge ❑ W.S.B.F.C. ❑ Temporary Construction Meter ❑ Turn on Charge ❑ Uncollected Account -Name ❑ Inspection Fee - Tract - 4 Fee - ❑ Plan Check Fees Water / Sewer - Tract - ❑ Bond Payment - A.D. - Bond ❑ Customer Deposit ❑ Other Na 36304 $ 1 6n U a4 /_ -, — , Tiof Katutnta Iluabing dub- �Sdfv 34tlmwon This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances ;,qf,the City regulating building construction or use: For the following: BUILDING ADDRESS 53-440.HERRERA Use Classification SINGLE FAMILY DWELLING Bldg. Permit No. _ Group R3 Type Construction VN Fre Zone Use Zone Owner of Building HARRY CHAPLIN Address P. 0. BOX 2084 City PALM DESERT, CA 92260 By; LONNIE DAY Date: JANUARY 28, 1992 Building Official POST IN A CONSPICUOUS PLACE 10165 SR Ell ' - TITLE 24 REPORT OR: ~ SUN COUNTRY CONSTRUCITON PLAN 1512 . LOT 14 BLOC�226 AVENIDA-HERRERA LA QUINTA, CA 92253 ~ . . . PROJECT DESIGNER: . SUN COUNTRY CONSTRUCTION 78-365 HIGHWAY 111, SUITE>166 LA QUINTA, CA 92253 (619) 564-4690 OWNER: MIKE WHITLEY ' 78-365 HIGHWAY 111, SUITE 166 LA QUINTA, CA 92253 ' ` ' ^ . . ' REPORT PREPARED BY: . SIERRA MECHANICAL ' 83-580 PEACH ST., SUITE #4 ' INDIO, CA 92201 (619) 345-4430 LICENSE #315890 Job Number: 1121�2 ' ' ' Date: 10/11/091 . � - - ' ' .. ' The COMPLY 24 computer program has been used to^perform the calculations summarized in this compliance report. This program has interim approval and is authorized by the California Energy Commission for u\se with the Second Generation Non&esidential Building Energy Efficiency Standards for Nonresidential Occupancies. Second Generation Residential Occupancies shown to comply with this program conform to the kes6lts produced bythe Public Domain Point System, developed by the Cplifornia Energy Commission. .This program developed by Gabel Dodd' Associates (415) 428-0803i - . '. •1 Table Of Contents for Title 24 Report Cover Page .......,..........<...................................... 1 Table of Contents ........................... ....... ....... 2 Form CF--IR Certificate of Compliance. Residential ............... Form MF--'1R Mandatory Measures Check:listb Residential ..........a..... 6 r Form P--2R Point_ System Summary .................. . .. ............. , . S Foray WS-••1F Points Thermal Mass Worksheet. ..... e ... . . ...... . . . . . . , .. 9 Form WS--2Fi Interpolation . Wor-i::sheet ...... .. o ...... „ .... .to Domestic_• Hot Water Worksheet. .. < .... ..,....... .....q ....... „ .. . .. is. Form S Shading Coefficient: (SC) Worksheet . .....,.>............. . 12 Form, WS-...4 HVAC System SUmmar•y Sheets .................. ......... < .. 17 HVAC 'Lone y Space Loads Summary ......................................... 18 P ' / CERTIFICATE OF COMPLIANCE: Residential (part 1 of 3) CF -1R page 3 of 20 . � ' _______________________________________________________ Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY`24 v 3.10 � Designer- SUN COUNTRY CONSTRUCTIONI Building Permit No | Location; Indio Date: 10/11/19911 Checked By, | Documentation: SIERRA MECHANICAL 1 Date (User # 2225) --------------------------------------------------r------------------------ PROJECT ADDRESS Job #: 1121-2 LOT 14 BLOCK 226 AVENIDA HERRERA LAQUINTA, CA 92253 GENERAL INFORMATION Compliance Method: Climate Zone: Total Conditioned Floor Area: Building Occupancy: Front Entry Orientation: Number of Dwelling Units: Floor Construction Type: Infiltration Control: BUILDING SHELL INSULATION Component Area R-13 Wall w/1" Thermax 1237 R-38 Roof/Gyp Ceiling* 1536 Carpeted Slab 1136 Exposed Slab 376 Point System 15 1512 sqft Single Fam Det West ' 1 Slab Standard U -Value Location/Comments 0.0514WHOLE HOUSE 0.0290 WHOLE HOUSE 0.7260 WHOLE HOUSE/Insul= R-0.0 0.9000 WHOLE HOUSE/Insul= R-0.0 THERMAL MASS Thick Mass Material Area (in) Type Location/Dbscription ----------- _--------- ____ _____ ---- ___ ______________________________ * Concrete, Heavyweight 1136 4.000 Covered WHOLE HOUSE/Int Mass Concrete, Heavyweight 376 4.000 Exposed WHOLE HOUSE/Int Mass . . / ` ` CERTIFICATE OF COMPLIANCE: Residential (part 2 of 3) CF -1R page 4 of 20 . --------------------------------------- -------- ______________________ Project: SUN COUNTRY CONSTRUCITON PLAN 1517 | COMPLY 24 v 3.10 Designer: SUN COUNTRY CONSTRUCTION | Building Permit No ' Location: Indio _ Date: 10/11/19q11 Checked By ` | - . Documentation: SIERRA MECHANICAL | Date (User # 2225) _________________-_________________________________________________________ ` GLAZING Glass w/Int ' .Location Orient Area Type U_Val SC Shade Description --------- ______ _____ ______ _____ _____ �____ ___________------ _----- ' � WHOLE HOUSE South 48.0 Double 0.6b 0.88 0.75 Double/Nonwhite Drapes West 6.8 Double 0.65 0.88 0.33 Doublf�/Light Blinds West 40.0 Double 0.65 0.88 0.33 Double/Light Blinds North 38.4 Double 0.65 0.88 0.75 �Double/Nonwhite Drapes East 35.4 Single 1.2c). 1.00 0.91 Single/NonWhite Drapes ' East 43.4 Single 1.10 1.00 0.91 Single/NonWhite Drapes . SHADI ` (for Glazing above) Over ` Locati'on Exterior Device SC hang Framing.Type ' ....................... ____ ____ _______________________ WHOLE HOUSE 50 % Bug Screen / .0.84 2.0 Metal w/Mullions . None 1.00 2.0 Metal w/o Mullions ' 50 % Bug Screen 0.84 2.0 Metal w/Mullions ` 50 % Bug Screen 0.84 2.0 Metal w/o Mullions None 1.00 15.0 Wood Door w/Mullions None 1.00 2.0 Wood Door w/Mullions . . ` . ' . ' ' ` . ° ' ' , . ` ` . / ' ` CERTIFICATE OF COMPLIANCE: Residential (part.3 of 3)CF-1R page 5 of 20 . . . Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 ^ � Designer: SUN COUNTRY CONSTRUCTION | Building Permit No - � Location: Indio Date: 10/11`/19911 Checked By | Documentation: SIERRA MECHANICAL 1 Date (User # 2225) ` ` / HVAC SYSTEMS Minimum Output Duct Duct Manufacturer/Model No. System Type Efficiency (Btuh) Location RVa1 !or approved equal) ' Heat Pump 7.100 HSPF 42000 Vent. Attic Space 5.2 CAR 38YK042-3/40YR042HP Heat Pump 10.000 SEER 42000 Vent. Attic Space CAR 38YK042-3/40YR042HP Max. Furnace Output: 45000 Btuh+ [(77% - 71%) x 7000] = 89985 Btuh Cooling Exception: ______ CFM Cooling (see Load Calcs) requires Btuh � ` HOT WATER SYSTEMS Tank Manufacturer/Model No. # of Energy R-12 System Type Volume (or approved equal) Sys Credits Blanket ___________________ ______ _______________________ _____ _______ _______ ` Electric Resistance 45.0 Rheemglas 81V -52D (SE) 1 2805 Y SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) COMPLIANCE STATEMENT This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24; Chapter 2"53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative Code. This certificate has been signed by theindividual with ov6rall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this Certificate of Compliance is submitted for a single building plan to be built in multiple orientations, all building Conservation features which vary are indicated in the Special Features/Remarks section. / DESIGNER � BUILDING OWNER SUN COUNTRY CONSTRUCTION MIKE WHITLEY 78-365 HIGHWAY 1119 SUITE 166 78-365 HTGHWAY,111, SUITE 166 LA QUINTA, CA 92253 LA QUINTA, CA 92253 (619) 564-4690 License No: Signed: DOCUMENTATION AU -OR ' SIERRA MECHANICAL 83 P AITT Sign /-��/ Signe ENFORCEMENT AGENCY Name: Agency: Telephonq:________ Signed:' (Date) ` NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items mar"ked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate,of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist.only. � BUILDING ENVELOPE MEASURES . Enforcement o Sec. 2-5352(a): Minimum ceiling insulation R-19 weighted average. * o Sec. 2-5352(b): Loose fill insulation manufacturers labeled RnValue. o Sec. 2-5352(c): Minimum wall insulation in'framed walls R-11 ' weighted average (does not apply to exterior mass walls). * ` o Sec. 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water'vapor transmission rate no greater than 2.0 perm/inch.� _ o Sec. 2-5311: Insulation specified or installed meets . California Energy Commission '(CEC) quality standards. Indicate type and form. o Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. ' o Sec. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. �. Doors and windows certified. co -Doors -and windows weatherstripped; all joints and penetrations caulked and sealed. � o Sec. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CK quality standards. o Sec. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Ti/ht fitting, closeable metal or glass door b. Outside,air intyk6 with damper and control c. Flue damper and control . 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 6 of 20 Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 Designer: SUN COUNTRY CONSTRUCTION | 1 Building Permit | No Location: Indio Date: 10/11/19911 Checked By Documentation: SIERRA MECHANICAL �-------------------------------------------------------------- � !-Date (User = ----------------- # 2225) NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items mar"ked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate,of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist.only. � BUILDING ENVELOPE MEASURES . Enforcement o Sec. 2-5352(a): Minimum ceiling insulation R-19 weighted average. * o Sec. 2-5352(b): Loose fill insulation manufacturers labeled RnValue. o Sec. 2-5352(c): Minimum wall insulation in'framed walls R-11 ' weighted average (does not apply to exterior mass walls). * ` o Sec. 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water'vapor transmission rate no greater than 2.0 perm/inch.� _ o Sec. 2-5311: Insulation specified or installed meets . California Energy Commission '(CEC) quality standards. Indicate type and form. o Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. ' o Sec. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. �. Doors and windows certified. co -Doors -and windows weatherstripped; all joints and penetrations caulked and sealed. � o Sec. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CK quality standards. o Sec. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Ti/ht fitting, closeable metal or glass door b. Outside,air intyk6 with damper and control c. Flue damper and control . 2. No continuous burning gas pilots allowed. ` ` MANDATORY MEASURES CHECKLIST (part 2 of 2) ' MF -1R' page 7 of 20 Project: SUN 'OUNTRY CONSTRUCITON PLAN 1512 COMPLY 24 v 3.10 | Designer: SUN COUNTRY CONSTRUCTION | Building Permit No Location: Indio Date: 10/11/1991| Checked By | Documentation: SIERRA MECHANICAL | Date (User # 2225) ___________________________________________________________=______________ ` HVAC AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 2-5352(g) and 2-5303: Space conditioning equipment , sizing: -attach calculations. ` o Sec. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. . o Sec. 2-5316(a): Ducts constructed� installed and insulated , � per Chapter 10, 1976 UMC. * ' o Sec. 2-5316(b): Exhaust systems have damper controls. o Sec. 2-5314(c): Gas2fired space heating equipment has intermittent ignition devices. ` o Sec. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. ` o Sec. 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage & backup.tinks for solar water heating systems; first 5 feet of pipes closest to tank insulated (R-3 or greater). o Sec. 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating piping. ' o Sec; 2-5318(d): Swimming Pool Heating 1. System has: ' a. On/off switch on heater. b. Weatherproof i� nstruction plate on heater. c. Plumbed to allow for solar. ' 2. 75 percent thermal efficiency.,, 3. Pool cover. 4. Time clock. ' 5! Directional.water inlet. ' LIGHTING AND APPLIANCE MEASURES oSec. 2-5352(j): Lighting - 25 lumens/watt or greater for`_ general lightihg in Vitchens and. bathrooms. o Sec. 2-5314(c\: Gas fired appliances equipped with intermittent ignition devices. ' o Sec. 2-5314(a): Refrigerators, refrigerator -freezers, ^freezer, and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. ' . , ` � POINTS SYSTEM SUMMARY: CLIMATE ZONE - ___.________________________________ 15 _ P-2R page 8 of 20 _ �____________�_�______________________ � Project: SUN COUNTRY CONSTRUCITON . � PLAN 1512 | COMPLY 24 . v 3.10 ' r | Designer: SUN COUNTRY CONSTRUCTION | Building Permit No Location: Indio Date: 10/11/1991| � Checked By Docum' tation: SIERRA MECHANICAL ------------------------ �______________________________________________ | Date (User # 2225) . BUILDING DATA ------------- Conditioned Floor Area 1512 sqft Number of Stories 1 Occupancy Type Single Fam Det SCORE CARD Measure _--- ______1. Points ------------ _-------- -------- 1.Roof Insulation 0.0290 (U-Value) O 2. Wall Insulation 0.0514 (U-Value) ' 3 3. Raised Floor Insulation ' 0.0000 (U-Value) - � ' 3a. Controlled Vent Crawlspace 0.0 (R-Value) | |-> 0 4. Slab Edge Insulation 0.7560 (f2 factor)-! 5. Infiltration Standard 0 6. Glass Heat Loss. 0.82 14.0% -3 Sum 1-6 0 7. Shade Open Area % Glass SC OH Eff % _____ _______ a. North 38.4 2.5 x ____ 0.74 = 1.9 0 b. East 78.8 5.2 x 0.92 x 0.77 = 3.7 -1 c. South 48.0 3.2 x 0.68 x 0.83 = 1.8 0 d. West `46.8 3.1 x 0.70 x 0.89 = 1.9 0 e. Skylight 0.0 .0.0 x 0.00 = 0.0 0 8. Shade Closed' Area% Glass _______ SC OH Eff % _____ a. North 38.4 2.5 x ____ 0.63 = 1.6 0 b. East 78.8 5.2 x 0.84 x 0.69 = 3.0 -5 c. South 48.0 3.2 x 0.58 x 0.63 = 1.2 1 d. West 46.8 3.1 x 0;26 x 0.83 = 0.7 3 e. Skylight 0.0 '0.0x 0.00 = 0.0 0 9. Interior Thermal Mass 2.54 0 ' . �s � 10 Exterior Wall Ma . 0 00 0 Sum 7-10 -2 . 11. Heating System 7.106 HSPF x 0.83 Duct Eff = 5.89 Eff HSPF 1 .Zonal Control: No ' 12. Cooling System 10.000 SEER x 0.82 Duct Eff = 8.20 Eff SEER 13 13. Water Heating (see DHW Worksheet) = -11 ' ' . ' . Point To .tal: 1 ` THERMAL MASS WORKSHEET . WS -1R page 9 of 20 . ___=----------------------- _------------- _____�--------------------- _______ Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 | Designer: SUN COUNTRY CONSTRUCTION | Building permit No | � Location: Indio � Date: 10/11/1991| Checked By . | Documentation: SIERRA MECHANICAL | Date (User # 2225) " ___________________________________________________________________________ INTERIOR'THERMAL MASS Interior Interior Sides Wall Mass Mass Mass Mass Material Thick ______________________ _____ ' Exposed U-VAlue _______ _______ ' Area ______ Factor ________ Capacity -------- Concrete, Heavyweight 4.00 0 1136.0 x 1.8 = 2067.5 'Concrete, H6avyweight 4.00 J376.0 x 4.7 = 1767.2 ' / ` ' TOTAL 3834.7 INTERIOR MASS FACTOR 3834.7 IMC / 1512 sft = 2.54 * Mass listed above with a Wall U -Value denotes the Interior Mass credit for Exterior Mass Walls, and are repeated below for Exterior Mass credit. 0 SidesExposed indicates mass covered with surface matyrAal >= R-2. EXTERIOR MASS WALLS ' Exterior "Exterior Sides Wall Mass Mass Mass � Mass Material Thick Exposed U -Value Area Factor Capacity � ______________________ _____ _______ _______ ______ ________ ________ NONE ` ` , INTERPOLATION, WEIGHTED AVERAGE & ADDITION WORKSHEET WS -2R page 10 of 20 � ___------ _----------------------- _------------------------------------------ Project: SUN COUNTRY CONSTRnCITON PLAN 1512 | COMPLY 24 v 3.10 | Designer: SUN COUNTRY CONSTRUCTION | Building Permit No | Location: Indio _ ' Date: 10/11/1991| Checked By � Documentation:� SIERRA MECHANICAL 1 Date (User #�2225) ----------------------------- _-------- _____________________________________ INTERPOLATION Point � � Point Point Score Actual Value 'Score Score Value Value Point Item 1 Value 1 2 1 2 1 Score _______ _____ _�____ _____ _____ _____ _____ ` _____ � Roof 4 +( 0.0290 - 0.02) x ( -4 - 4) /( 0.04 - 0.02> = 0 Wall 6 +( 0.0514 - 0.04) x ( 1 - 6) /( 0.06 - 0.04) = 3 Slab Edge 2 +( 0.7569 - 0.70) x ( -1 - 2) /( 0.80 - 0.70) = 0 Glass Type 1 -11 +(14.0212 -14.00) x ( -13 - -11) /(15.00 -14.00) = -11 Glass Type 2 2 +(14.0212 -14.00) x ( 1 - 2) /(15.00 714.00) = 2 N Shade Open 0 +( 1.8881 - 1.00) x ( 0 - 0) /( 2.00 - 1700) = 0 E Shade Open -1 +( 3.6882 - 3.00) x ( -1 - -1) /( 4.00 - 3.00> = -1 S Shade Open 0 +( 1^8123 - 1"00) x ( 0 - 0) /( 2.00 - 1.00) = 0 W Shade Open 0 +( 1.9142 - 1.00) x ( O - 0) /( 2.00 - 1.00) = 0 N Shade Clsd 0 +( 1.6091 - 1.00) x ( 0 -' 0) /( 2.00 - 1.00) = 0 E Shade Clsd -5 +( 3.0037 - 3.00) x ( -8 - -5) /( 4.00 - 3.00) = -5 S Shade Clsd 2 +( 1.1603 - 1.00) x ( -2 - 2) /( 2.00 - 1.00> = 1 W Shade Clsd 6 +( 0.6715 - 0.00) x ( 2 6) /( 1.00 - 0.001 = 3 rnt Mass 0 +( 2.5362 - 2150) x ( 1'- 0) /( 3.00 - 2.50> = 0 Heating 1 +( 5.8896 5.50) x ( 2 - 1) /( 6.42 - 5.50) = 1 Cooling 11 +( 8.1952 - 8.00) x ( 20 - 11) /( 9.00 - 8.00) 13 WEIGHTED AVERAGE POINTS Type 1 Type 2 ' Type 3 Total Average Item Points Area ______ Points ______ Area Points ______ � Area ____ Area _____ Points --------- ______Glass ___ GlassType 1,2&3(-11.0 ____ x 79 + 2.0 ____ 9 133 + 0.0 x 0) /. 212 = -3 n ` DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 11 of 20 Project: SUN COUNTRY CONSTRUCITON PLAN 1512 } COMPLY 24 v 3.10 . | Designer: SUN COUNTRY CONSTRUCTION. | Building Permit No | Location: Indio Date: 10/11/1991| Checked By | Documentation: SIERRA MECHANICAL | Date (User # 2225) ___________________________________________________________________________ A EQUIPMENT DATA � 15 ---- 1 ______________________________------------------------------------------ Water heater type SE Enter SG or SE ` 2 Manufacturer & 140 F, fixed input 3 Model number 70.0 Rheemglas 81V52D (SE) 4 Ignition d .vice, IID GP, gas pilot or IID, int. ignition device 5 Tank volume 45.0 Total gallons, from CEC ApplianceDirectory 6 Recovery efficiency 99.7 Percent from CEC Appliance Directory 7 Standby loss- 0.7 Perceht/hour, from CEC Appliance Directory 8 Rated input 39249 Btu/hr, from CEC Appliance Directory 10 Pumping energy 0.0 (1 kWh - 3413 Btu) 9 Number of Heaters 1 From building plans (total) 10 Insulation Jacket Y (Y/N) R-12 insulating jacket on the plans B OPERATING DATA 1 Climate Zone 15 See Appendix D .2 Water heating budget 18700 KBtu/yr/unit, see Table 1 3 Tank set temp. 140 F, fixed input 4 Water main temp. 70.0 F, see Table 1 5 Daily hot water load 50 50 or 35 gallons/unit, see Table 1 6 Ambient air temp. 72.6 F, see Table 1 7 Adj Standby Losses 0.0055 . See Table 2 or Appendix B 8 No. dwelling units 1 From building plans (total) 9 Number of pumps 0 From building plans 10 Pumping energy 0.0 Watt-hr/yr per Pump, see Table 3 C WATER HEATING ENERGY CREDITS ___________________________________________________________________________ 1 � Credit nameSee Table 5 � ` 2 Annual savings 2805.0 KBtu/yr/dwelling unit, see Table 5 D CALCULATE ANNUAL WATER HEATING ENERGY (KBtu/yr) . ___________________________________________________________________________ 1 Recovery load 7734.4 {[05 x 8.29 x(146 -B4)0 365 x 0.001i-C21x B8 2 Recovery energy 7757.6 D1 / A6 ' 3 Standby loss energy 1172.4 124 - [(D2 x 1000)/(A8 x Aq x 365)]} x 8.25 x A5 x B7 x 365 x (140-B6) , 0.001 x A9 4 Pumping energy- 0.0 B9 x B10 x 3.413 x 3 x 0.001 5 Total energy 26790.1 GAS SYSTEMS: (D2 + D3 + D4) / BB ELECTRI& {[(D2 + D3) x 31 + D4} / B8 6 Water heating budget comparison -8090.1 KBtu/yr/unit B2 - D5 7 Water heating budget -10.7 Points (D6 / Floor Area) x 2 x B8 M ' ` Glazing Type: Double 0.84 . SHADING COEFFICIENT (SC) WORKSHEET ' ' FORM S page 12 of 20 Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 Designer: SUN COUNTRY CONSTRUCTION / � � Interior Shade Type: Building Permit No Location: Indio Date: | 10/11/1991| | SC Shade Open: 0.88 Checked By S. Documentation: SIERRA MECHANICAL' ___________________________________________________________________________ 1 Date (User ` # 2225) GENERAL INFORMATION 1. Glazing Type: Double 0.84 3. Framing Type: Metal w/Mullions 5. Framing/Mullion Factor: 0.81 (from Table G-10) 6. Interior Shade Type: Double/Nonwhite Drapes 7. SC Shade Open: 0.88 . (from Table G-9 or show calculation) S. SC Shade Closed: 0.75 (from Table G-9 or show calculation) GLAZING, INTERIOR -SHADE & FRAMING 9a. 0.88 (SC #7) x 0.81 (FMF #5) = 0.71 SC Shade Open 10a.0.75 (SC #8) x 0.81 (FMF #5) = 0.61 SC Shade Closed EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen ` 11. SC Exterior Shade: 0.84 (from Table G-11 or manufacturer's data) 12. [(0.84 (SC ' #11) x 0.25) + 0i75] x 0.71 (SC #9a) = 0.68 SC Shade Open 13. [(0.84 (SC #11) x 0.25) + 0.753 x 0.61 (SC #10a) = 0.58 SC Shade Closed OVERHANG FACTOR Glass Ovrhng Dist Glass Proj OH Factor OH Factor Orientation Area Depth Above Height Ratio Shade Open Shade Clsd ___________ _____ ______ _____ ______ _____ __________ ---------- South 48.0 2.0 / ( 0.1 + 4.0) = 0.49 0.83 0.63 4% V GENERAL INFORMATION 1. Glazing Type: Double ` SHADING COEFFICIENT (SC) WORKSHEET - --------------------------- ---------------------------------- ,FORM S page 13 _________�___ of 20 Project: SUN COUNTRY CONSTRUCITON PLAN 1512 Metal COMPLY 24 v 3.10 Designer: SUN COUNTRY CONSTRUCTION | � Building Permit No Lpcation: Indio Date: 10/11/1991| Checked By Documentation: SIERRA MECHANICAL ' � � ___________________________________________________________________________ � � | Date (User # 2225) GENERAL INFORMATION 1. Glazing Type: Double 3. Framing Type: Metal w/o Mullions 5. Framing/Mullion Factor: 0.88 (from Table G-10) 6. Interior Shade Type: Double/Light Blinds . 7. SC -Shade Open: 0.88 (from Table,G-q or show calculation) 8. SC Shade ' Closed: 0.33 (from Table G-9 or show calculation) ' GLAZING, INTERIOR SHADE &FRAMING 9a, 0.88 (SC #7) x 0.88 (FMF #5) = 0.77 SC Shade Open 10a.0.33 (SC #8) x 0.88 (FMF #5)'= 0.29 SC Shade Closed ' EXTERIOR'SHADE OVERHANG FACTOR Glass Orientation Area ___________ ----- West 6.8 Exterior Shade Type: NO EXTERIOR SHADE Ovrhng Dist Glass Proj OH Factor OH Factor Depth Above Height Ratio. Shade Open Shade Clsd ______ _____ __________ __________ � 2.0 / ( 0.1 +. 6.8) = 0.29 0.91 0.87 ^ N ` � SHADING COEFFICIENT (SC) WORKSHEET � FORM S page 14 of 20 -------- ____----------------------------------- Project: SUN COUNTRY.CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 ' | Designer: SUN'COUNTRY CONSTRUCTION | Building Permit No | Location: Indio Date: 10/11/1991| Checked By � Docum6ntation: SIERRA MECHANICAL | Date (User # 2225) -------------------------- _________________________________________________ GENERAL INFORMATION 1. Glazing Type: Double 3; Framing Type: Metal w/Mullions 5. Framing/Mullion Factor: 0.81 (from Table 6-10) . 6. Interior Shade Type: Double/Light Blinds 7. SC Shade Open: 0.88 (from Tdble G-9 or show calculation) S. SC.Shade Closed: 0.33 (from Table G-9 or show calculation) ° GLAZING, INTERIOR,SHADE & FRAMING � ' 9a. 0.88 (SC 47) x 0.81 (FMF #5) = 0.71 SC Shade Open 10a.0.33 (SC #8) x 0.81 (FMF #5) = 0.27 SC Shade Closed EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen 11. SC Exterior Shade: 0.84 (from Table 0-11 or manufacturer's data) 12. [(0.84 (SC #11) x 0.25) + 0.751 x 0.71 (SC #9p) = 0.68 SC Shade Open 13. [(0.84 (SC #11) x 0.25) + 0.751 x 0.27.(SC #10a) = 0.26 SC Shade Closed OVERHANG FACTOR Glass Ovrhng Dist Glass Proj OH Factor OH Factor Orientation Area Dppth� Above Height Ratio Shade Open Shade Clsd � ___________ _____ ______ _____ ______ _____ __________ ----------- West _________West 40.0 2.0 / ( 0.1 + 510) = 0.39 0.88 0.82 ` � ` SHADING COEFFICIENT (SC) WORKSHEET FORM S page 15 of 20 ` Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10' | Designer: SUN COUNTRY CONSTRUCTION | Building Permit No | �� Locati"n: Indio nate: 10/11/1991| Checked By � Documentation: SIERRA MECHANICAL | Date (User # 2225) --------------------------------------- 7-7 -- � GENERAL INFORMATION 1. Glazing Type: Double' 3. Framing Type: Metal w/o Mullions 5. Framing/Mullion Factor: 0.88 (from Table G-10) 6. Interior Shade Type: Double/Nonwhite Drapes 7. SC Shade Open: 0.88 (from Table G-9 or show calculation) q. SC Shade Closed: 0.75 <from Table 8-9 or show calculation) / GLAZING, INTERIOR SHADE & FRAMING 9a. 0.88 (SC #7) x 0.88 (FMF #5) =, 0.77 SC Shade Open 10a.0.75 (SC #8) x 0.88 (FMF #5) = 0.66 SC Shade Closed EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen ' 11. SC Exterior Shade: 0.84 (from Table G"11 or manufacturer's data) 12. [(0.84 (SC #11) x 0.25) - + 0.75] x 0.77 (SC #9a) = 0.74 SC Shade Open 13. [(0.84 (SC #11) x 0.25) +,0.751 x'0.66 (SC #10a) = 0.63 SCShade Closed OVERHANG FACTOR Glass! Ovrhng Dist Glass Proj OH Factor OH Factor Orientation Area Depth' Above Height Ratio Shade Open Shade Clsd ___________ _____ ______ _"___ ______ _____ __________ ------------ ,NO _________'NO OVERHANGS . v ` SHADING COEFFICIENT (SC) WORKSHEET FORM S page 16 of 20 � _____________________________________-_____________________________________ Project: SUN COUNTRY CONSTRUCITON PLAN 1512 COMPLY 24 v 3.10 | ' Designer: SUN COUNTRY CONSTRUCTION | Building Permit No | Location: Indio Date: 10/11/1991| Checked By . � Documentation: SIERRA MECHANICAL ` .| Date (User # 2225) -------------- ----------------------------------- ---------------------��� ' ` GENERAL INFORMATION ' 1. Glazing Type: Single 3. Framing Type:� Wood Door w/Mullions . 5. Framing/Mullion Factor: 0.92 (from Table G-10> 6. Interior Shade Type: Single/NonWhite Drapes 7. SC Shade Open: 1.00 (from Table G-9 or show calculation) 8. 8C Shade Closed: 0.91 (from Table G-9 or show calculation) . GLAZING, INTERIOR SHADE & FRAMING ' 9a. 1.00 (SC #7) x 0.92 (FMF #5)'= 0.92 SC Shade Open ' 10a.0.91 (SC #8) x 0.92 (FMF #5) = 0.84 SC Shade Closed EXTERIOR SHADE OVERHANG FACTOR Glass Orientation Area ___________ East 35.4 East 43.4 Exterior Shade Type: NO.EXTERIOR SHADE Ovrhng Dist Glass Proj OH Fact6r OH Factor Depth ______ Above _____ Height ______ Ratio _____ �Shade Open ---------- Shade Clsd __________ 15.0 / ( 0.5 ` + 6.8)-= 1.70 0.58 0.47 2.0 / ( 0.1 + 6.8> = 0.29 0.92 0.87 N ` . « HVAC SYSTEM SUMMARY SHEET WS-4 page 17 of 20 . __=__________________._L___________________________________________________ Prqject: SUN COUNTRY CONSTRUCITON PLAN 1512 1 COMPLY 24 v 3.10 | Designer: SUN COUNTRY CONSTRUCTION 1 Building Permit No .| Location: Indio ` Date: 10/11/1991| Checked By | ' . Documentation: SIERRA MECHANICAL | Date (User # 2225) ------------------------------ --- --------- 7-----7 ----------�������������� � HEATING Heating System Name: System Type: Output Capacity: Rated SSE or COP: Supply Air Temperature: COOLING � Cooling System Name: System Type: : Aotal Output Capacity: Sensible Output Capacity: Latent Output Capacity: Rated EER: Coil Bypass Factor: _ Economizer: Supply Air Temperature: FANS / Supoly Air CFM: Fan Type: ' Fan Multiplier: Brake Horsepower: Motor Efficiency:, ' Drive Efficiency: Fan Type: Fan Multiplier: Brake Ho"sepower:' Motor Efficiency: Drive Efficiency: ' DUCTS Supply Duct Heat Gain: Return Duct Heat Gain: Supply Duct Air Leakage: Return Duct Air Leakage: CAR 38YK042-3/40YR042HP Heat Pump 42000 Btu/hr ^ ` 2.980 105 F �^ CAR 38YK042-3/40YR042HP Heat Pump. 42000 Btu/hr 31300 Btu/hr 10700 Btu/hr 9.000 0.100 ' . No 55 F 1565 cfm Draw -Through 1 0.50 95.0 % 100.0 % Draw -Through 1 ' 0.43 95.0 % 100.0 % 5.0 % 1.0 % 2.0 % 2.0 X x � HVAC ZONE HEATING & COOLING LOAD SUMMARY . _______________________-___________________________-____________________ page 18 of 20 Projept: SUN COUNTRY CONSTRUCITON PLAN 1512 1 COMPLY 24 v 3.10 Designer: SUN COUNTRY CONSTRUCTION ` � 1 | Building Permit No / Location: Indio , Date: 10/11/1991\ Checked By � Documentation: SIERRA MECHANICAL ----------- _________------------------------------------------ .| | Date (User # 2225) � ' HVAC ZONE DESCRIPTION4 HVAC Zone Name: WHOLE HOUSE Heating System Name: CAR 38YK042-3/40YR042HP Cooling System Name: _ CAR 38YK042-3/40YR042HP System Multiplier: 1 Heating Schedule: Residential Heating Cooling Schedule; Residential Cooling Fan Schedule: Residential HVAC & Fans ' Peak Load Method: COINCIDENT Relative Humidity: 50 % COOLING SPACES IN THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT WHOLE HOUSE (Jan 12am) 25994 (Aug *2pm) 22921 680 - TOTAL SPACE LOAD 25994 22921 680 ` Bypass Ventilation Air ( 0 cfm) . 0 ( 0 cfm) 0 -0 Supply Duct Conduction 1300 ' 1146` . Supply Duct Leakage 520 458 14 Supply Fan Heat Gain ^ -2492 2492 EFFECTIVE SPACE LOAD ------- 25321 --- ---- ------- 27018 694 Ventilation ( 0 cfm) 0 ( 0 cfm) 0 -0 Return Air Lighting Gain 0 Return Duct Conduction 253 270 ' Return Duct Leakage 506 540 14 Return Fan Heat Gain -0 0 TOTAL SYSTEM LOAD' 26081 27829 707 2.3 tons 0.1 tons SYSTEM PERFORMANCE ' 29337 30505 7323 AT DESIGN CONDITIONS 2.5 tons 0.6 tons ' ` ` RESIDENTIAL SPACE HEATING LOAD SUMMARY . page 19 of 20 --------------------- _----------- ______---------- __________---- _--------- � Project: GUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 v 3.10 | . Designer: SUN COUNTRY CONSTRUCTION 1 Building Permit No ` | Location: Indio � _ Date: 10/11/19911 Checked By � ' Documentation: SIERRA MECHANICAL 1 Date (User # 2225) ------------------ _--------------------------- _---------- __________-___ Space Name: WHOLE HOUSE Design Indoor Dry Bulb T6mperature: 70 F Design Outdoor Winter Dry Bulb Temperature:' 29 F' Design Temperature Differen,ce: 41 F ' Conduction _________________ Area ' U -Value TD ____ Btu/hr R-13 Wallj w/1" Thermax ______ 1237.0 x _______ 0.0514 x 41.0 ______ = 2607 Double/Nonw'ite Drapes- ' 06.4 x 0.6500 x 41.0 =' 2303. Double/Light Blinds 46.8 x '0.6500 x 41.0 = 1247 Single/NonWhite Drapes 78.8 x 1��1000 x 41.0 = 3554 R�38 Roof/Gyp Ceiling 1536.0 x 0.0290 x 41.0 = 1829 Carpeted Slab Perim = 128.O x 43 = 5504 Exposed Slab � � Perim,= 33.0, � x 43 � , Infiltration: 1.00 x 0.018 x 1512 sqft x 9.0 ft x 0.75 AC x 41.0 = `7532 ' TOTAL HOURLY HEAT LOSS FOR SPACE 25994 SUPPLY AIR QUANTITY ` -------------- Heating: 25994 Btu/hr / [1.10 (105 F Supply - V F Stat)] = 591' cfm ' ` ` RESI.DENTIAL SPACE COOLING LOAD SUMMARY . ----------------------------- W______-______________________________________ ' page 20 of 20 Project: SUN COUNTRY CONSTRUCITON PLAN 1512 | COMPLY 24 y 3.10 ' . Designer: SUN COUNTRY CONSTRUCTION | | Building Permit No � Location: Indio Date: 10/11/19911 Checked By Documentation: SIERRA MECHANICAL | | Date (User_# 2225) Space Name: . WHOLE HOUSE Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference: 34 F Conduction Area U -Value DETD Btu/hr R-13 Wall w/1" Thermax 1237.0 x ___..... 0.0512 x 29.6 = 1874 Double/Nonwhite Drapes 86.4, x 0.6179 x 34.0 = 1815 Double/Light Blinds 46.8 x 0.6179 x 34.0 = 983 Single/NonWhite Drapes 78.8 x. 1.0110 n 34.0 = 2709 R-38 Roof/Gyp Ceiling 1536.0 x 0.0284 x 50.0 2185 Infiltration: 1.00 x 0.018 x 1512 sqft x 9.0 ft x 0.75 AC x 34.0 = 6246 Shaded Unshaded Solar Gain Orient. _________ Area SGF ____ ___ Area SGFSC Btu/hr _________________ Double/Nonwhite Drapes South [ 48.0 x 15 + ____ ___ ____ 0.0 x 32] x 0.58 ------ = 420 Double/Light Blinds West [ 1.5 x 15 + 5.3 x 73] x 0.29 = 119 Double/Light Blinds. West [` 12.0 x 15 + 28.0` x 731 x 0.26 = 571 Double/Nonwhite Drapes North [ 0.0 Y 15 + 38.4 x 15].x 0.63 = 365 Single/NonWhite Drapes East [ 35.4 x 15 + 0.0 V731 x 0.84 = 445 Single/NonWhite Drapes East ' [ 9.6 x 15 + 33.8'x 73] x 0.84 = 2188 Internal Gain ^fOp Frac. Area Heat Gain Conv., Btu/hr _______________________ -------- Lighting 1.00. ______ x 1512.0 _________ x _____ 0.200 x 3.413 = 1032 Equipment 1100 x 1512.0. x 0.250 x 3.413 = 1290 Occupants 1.00 x 1512.0 x 225 / _500 = 680 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 22921 ` Latent Gain Op Frac. Area Heat Gain Conv. Btu/hr Equipment 1.00 x 1512.0 _________ x _____ 0.000 x 3.413 = 0 Occupants 1.80 x 1512.0 x 225 / 500 = 680' ' TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 680 SUPPLY.AIR QUANTITY ------------ _------ Cooling: 22921 Btu/hr / [1.08* ( 78 F TStat - 55 F Supply)] = 923 cfm 0 • (M. HEATING { COOLING Product Data 1989 38YK (60 Hz) Heat Pump Sizes 018 thru 060 The 38YK Outdoor Sections of split -system heat pumps are designed for quiet, reliable heating during the winter and cooling during the summer. These heat pump systems provide economy of operation through energy conservation. They recover heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, remove indoor heat and excess humidity during the cooling season. All models have ARI certified ratings and are UL and CSA listed. All models available in 208/ 230 volts, single phase, 60 hertz. FEATURES/BENEFITS Compressor — Designed specifically for heat pump duty, with high energy efficiency during heating and cooling operation. Each compressor is hermetically sealed against contamination to assure long life and dependable performance, internally sprung and externally mounted on rubber isolators for quiet operation. For improved serviceability each compressor, except 5 ton units, is equipped with a compressor terminal plug. Continuous compressor operation is approved down to — 30 F in the heating mode, and down to 55 F in the cooling mode. (See heating and cooling performance tables.) All models include a discharge -tube muffler to prevent sound transmission of the compressor pulsations to the indoor or outdoor coils. Built -In -Reliability Components — Includes a suction -tube accumulator that keeps liquid refrigerant from reaching the compressor; a liquid tube low-pressure switch that stops the compressor if refrigerant charge is Form 38YK-2PD f lost; a crankcase heater to keep the compressor oil warm and free of refrigerant for maximum lubricity; an internal compressor relief valve for high-pressure protection; and compressor start capacitor and relay components to assure reliable z, operation of the units during brownout conditions and low outdoor °y. temperatures. Defrost Control Board — Incorporates a defrost relay, defrost timer, and low -voltage terminal board. The defrost control is a time/ temperature initiation/termination control which includes three field - selectable time periods of 30, 50, and 90 minutes. Weather -Protective Cabinet — Steel is protected with a heavy coating commonly called "galvanizing," then coated with a layer of zinc phosphate to which a coat of modified polyester powder coating is applied and baked - on. This provides each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting rust -resistant, quality'appearance. Unit Design — All units are equipped with totally enclosed fan motors for greater reliability under rain and snow conditions. The large, wraparound coil uses copper tube and enhanced aluminum fin and is designed for optimum heat transfer during heating and cooling. The vertical air discharge carries the sou>id and air up and away from adjacent patio areas and foliage. Sufficient space is provided between rows of composite coils so they can be cleaned with a common garden hose. External Service Valves — Both service valves are brass, back seating type with sweat connections. Each valve has a service port for ease of checking operating refrigerant pressures. Features — Sound shield on 024 thru 060 sizes and bi-flow thermostatic expansion valve for indoor coil. AWeather Armor" II Cabinet ® High -Efficiency Fan Motor Precision -Matched Fan '. O. Vertical Exhaust vHeavy -Gauge Protective Grille OTotal Service Access 2 O Copper. Tube/Aluminum Fin Coil QSolid Brass Service Valves I 0 Accumulator Low -Pressure Switch Chronotemp IIT" Defrost Control ® High -Precision Reversing Valve 53 ®. Heat -Pump -Tough Compressor O4' fi Compressor Crankcase Heater ® Compressor Isolation Pads e High -Relief Basepan •J I • 38YK030-00/ Indoor Coil Airflow 40A0031 I Cfm• 1125 Instantaneous Capacity (MBtuh) Integrated Capacity (MBtuh)t Total Power Input (KW)$ HEAT PUMP HEATING PERFORMANCE Indoor Section EDB Heating Capacity OUTDOOR COIL ENTERING AIR TEMPERATURE F Indoor Section Size Heating Capacity 700 -3 7 17 27 37 47 57 67 10.2 13.5 17.3 21.2 25.8 31.1 38.0 45.3 9.35 12.4 15.7 18.8 23.5 31.1 38.0 45.3 2.13 2.28 2.43 2.59 2.75 2.93 3.15 3.39 Multinliers for Determinino the Performance With Other Indoor Sections 40AQ 031 1.00 Indoor Section Size Heating Capacity Power Indoor Section Size Heating Capacity Power 28HONG 036 0.99 0.97 28RM 036 0.97 0.99 28RD 136 0.99 0.97 28SL 030 0.97 0.99 28RD/RN 130 0.97 0.97 036 0.99 0.99 38.2 030 0.97 0.97 40AQ 031 1.00 1.00 036 0.99 0.97 036 0.99 0.99 28RH 030 0.97 0.97 40RC 030 0.99 1.01 036 0.99 0.97 043 1.00 1.00 Indoor Section Size Capacity Heating Power Indoor Section Size Heating Capacity . 38YK036-00/ 40OB/QH043 I Indoor Coil Airflow Cfm' 1350 042 I EDB 1.01 OUTDOOR COIL ENTERING AIR TEMPERATURE F 036 0.96 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity MBtuh 15.0 18.7 22.7 27.2 32.3 38.2 45.6 53.2 Integrated Capacity MBtuh 13.8 17.2 20.7 24.2 29.4 38.2 45.6 53.2 Total Power Input K t 2.68 2.85 3.02 3.18 3.37 3.58 3.88 4.21 1.02 Mnitinliam fnr rlatprmininn the Parfnrmnnra With rlthar Inrinnr Sartinns 043 0.97 0.99 Indoor Section Size Capacity Heating Power Indoor Section Size Heating Capacity . Power 28HQ/V0 042 0.97 1.01 28RH 036 0.96 1.01 28RD 136 0.96 1.01 042 0.96 1.01 28RD/RN 036 0.96 1.01 28RM 036 0.95 1.07 43.3 042 0.96 1.01 28SL 036 0.97 1.06 142 0.97 1.02 042 0.97 1.02 Multinliers for Determinino the Performance With Other Indoor Sections 043 0.97 0.99 40QB/QH 042 0.99 0.99 143 0.97 0.99 043 1.00 1.00 242 0.97 1.01 048 0.98 0.98 Indoor Section Size Hea ing Capacity Power Indoor Section Size Heating Capacity 38YK042-00/ 40QB/QH049 I Indoor Coil Airflow Cfm• 1575 048 I EDB 1.00 OUTDOOR COIL ENTERING AIR TEMPERATURE F 042 0.97 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity MBtuh 18.3 22.4 26.8 31.5 36.9 43.3 51.0 58.8 Integrated Capacity MBtuh 16.9 20.6 24.4 28.0 33.5 43.3 51.0 58.8 Total Power Input K 3.02 3.21 3.40 3.59 3.80 4.06 4.40 4.79 0.98 Multinliers for Determinino the Performance With Other Indoor Sections 043 0.98 0.98 Indoor Section Size Hea ing Capacity Power Indoor Section Size Heating Capacity Power 28HONO 048 0.98 1.00 28RH 042 0.97 1.00 28RD 048 0.99 1.00 048 0.99 1.00 29.7 35.0 40.9 049 0.99 0.98 28RM 048 0.98 1.01 28RD/RN 042 0.97 1.00 28SL 042 0.97 1.00 142 0.97 1.00 049 0.98 0.98 Multinliprc fnr nptprmininn tho PPrfnrmnnra With r)thpr Inrinnr Cartinne 043 0.98 0.98 40QB/QH 042 0.99 0.99 143 0.98 •0.99 043 0.99 0.98 242 0.97 1.00 048 0.98 0.98 148 0.99 1.00 049 1.00 1.00 248 0.98 1.00 See notes on page 12. HEAT PUMP HEATING PERFORMANCE 38YK048-00/ Indoor Coil Airflow Capacity EDB Indoor Section OUTDOOR COIL ENTERING AIR TEMPERATURE F Heating Capacity Power 4008/1 I Cfm• 1800 0.99 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity MBtuh 20.5 24.9 29.7 35.0 40.9 48.2 56.4 62.8 Integrated Capacity MBtuh t 18.8 22.9 27.1 31.1 37.2 48.2 56.4 62.8 Total Power Input K $ 1 3.47 3.68 3.89 4.10 4.33 4.63 4.95 5.22 248 0.96 1.01 Multinliprc fnr nptprmininn tho PPrfnrmnnra With r)thpr Inrinnr Cartinne 1.00 060 1.00 1.00 062 0.99 Indoor Section Size Capacity Heating Power Indoor Section Size Heating Capacity Power 28HONO 060 0.99 1.00 28RM 048 0.96 1.02 28RD 048 0.98 1.01 28SL 049 0.97 1.00 049 0.98 1.00 061 0.99 0.99 28RD/RN 148 0.98 1.01 40QB/QH 048 1.00 1.00 057 0.98 1.00 049 1.00 1.00 248 0.96 1.01 060 0.99 1.00 060 1.00 1.00 062 0.99 1.00 061 0.99 0.99 063 0.99 0.99 28RH 048 0.98 1.01 060 0.98 1.00 38YK060-00/ 40QB005 & 315016-402 Indoor Coil Airflow Cfm • 2000 EDB 700 Power Indoor Section OUTDOOR COIL ENTERING AIR TEMPERATURE F Heating Capacity Power -3 7 17 27 37 47 57 67 Instantaneous Capacity MBtuh 22.6 29.3 36.0 43.1 51.0 61.0 73.1 85.9 Integrated Capacity MBtuh t 20.8 26.9 32.8 38.2 46.4 61.0 73.1 85.9 Total Power Input (K t 3.87 1 4.22 1 4.56 1 4.90 5.26 1 5.68 6.19 6.73 Multinliers for Determinino the Performance With Other Indoor Sections Indoor Section Size Heating Capacity Power Indoor Section Size Heating Capacity Power 28RD/RN 057 0.95 1.01 4008 160 0.98 1.02 0.99 060 0.96 1.00 40QB/QH 060 1.00 1.07 28RH 061 1 0.96 1.00 1 062 1 1.00 1.05 060 0.95 1.01 1 063 1 0.98 1.03 28SL 061 0.97 1.00 40QB + 315016-402 005 1.00 1.00 'See the Heating Performance Correction Factors Table for Cfm and indoor coil entering air temperature adjustments. tThe Btuh heating capacity values shown are net "integrated" values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. $The KW values include the compressor, outdoor fan motor, and indoor blower motor. The KW from supplement heaters should be added to these values to obtain total system KW. EDB = Entering Dry Bulb. HEATING PERFORMANCE CORRECTION FACTORS Indoor Coil Cfm Correction Factors per 12,000 Btuh of Capacity Power ARI Cooling Capacity 400 0.99 1.01 450 1.00 1.00 500 1.01 0.99 Indoor Coil Entering Air Temp F (DB) 65 1.01 0.97 70 1.00 1.00 75 0.99 1.03 System Design 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 ins. water column. 2. Minimum outdoor operating air temperature for cooling mode without low ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature for cooling mode is 125°F (51.71C). 4. Minimum outdoor operating air temperature for heating mode is - 30°F (- 34.4°C). 5. Maximum outdoor operating air temperature for heating mode is 66°F (18.91C). 6. For reliable operation, unit should be level in all horizontal planes. 7. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft. Indoor coil below = 150 ft. (See items 8 and 9 following.) 8. For inter -connecting refrigerant tube lengths greater than 50 ft, consult long tube application bulletin available from equipment distributor. 9. Not more than 3 ft of refrigerant tube should be buried in the ground. If necessary to bury tubes under a sidewalk, provide a minimum 6 -in. vertical rise to the valve connections at the unit. 10. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 11. Mixmatches of indoor coil capacity more than one size larger than outdoor unit capacity may result in inadequate indoor comfort. Accessory Description and Usage 1. Motormaster-Low Ambient Operation Kit This solid state head pressure controller is a fan speed control device activated by a temperature sensor. It is specifically designed to control outdoor fan motor speed in response to saturated condensing temperature. For outdoor air temperatures between 550 and 0°F (12.8° and - 17.81C), it maintains condensing temperature at 100°F + / - 10°F (37.80 + / - 50C). For single phase units a ball bearing fan motor is also required. SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C). All commercial installations. (Note: 3 phase units have ball bearing fan motors as standard) 2. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all single phase units where LOW AMBIENT OPERATION KIT (Item 1) has been added. 3. Winter Start Control A SPST delay relay which bypasses the low pressure switch for approximately 3 minutes to permit start-up for cooling operation under low load conditions. SUGGESTED USE: All heat pumps where LOW AMBIENT OPERATION KIT (Item 1) has been added. 4. Evaporator Freeze Thermostat A SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where WINTER START CONTROL (Item 3) has been added. 5. Isolation Relay A SPDT relay which switches the low ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE: All heat pumps where LOW AMBIENT OPERATION KIT (Item 1) has been added. 6. Time Guard IIT" Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5 -minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to "play" with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 -feet. High rise applications. 7. Sound Blanket/Shield/Hood Wrap around sound attenuation cover for the compressor. Reduces the sound level by about 0.2 bels. SUGGESTED USE: Unit installed closer than 15 -feet to quiet areas -bedrooms, etc. Unit installed between two houses less than 10 -feet apart. 8. Outdoor Thermostat A SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with single stage supplemental heaters smaller than 30 KW. 9. Secondary Outdoor Thermostat A SPDT temperature actuated switch which turns on second stage of supplemental electric heaters when outdoor air temperature drops below the second stage set point. SUGGESTED USE: Heat pump installations where two stage operation of supplemental heaters is desired. 10. Service Sentry A current sensing lockout relay which provides immediate notification that compressor is not operating during a call for heating or cooling. Used with proper room thermostat, the thermostat light is turned on signifying service is required. This can minimize electricity cost increase due to operation on supplemental heaters only. SUGGESTED USE: As a feature to notify owner immediately when the system is not operating most efficiently. 11. Optimizer II An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a predeter- mined economic balance point temperature. then switches to allow furnace operation only below that temperature. Requires OUTDOOR THERMOSTAT (Item 8) adjusted for economic balance point temperature. SUGGESTED USE: All heat pump and gas- or oil -fired furnace combination systems. 12. Refrigerant High Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 psig. Provides additional protection against compressor damage due to loss of outdoor air flow. To prevent rapid compressor recycling, COMPRESSOR SHORT CYCLE PROTECTOR (Item 6) can be used with this switch. SUGGESTED USE: Installations exposed to very "dirty" outdoor air. Installations where condenser inlet air temperature exceeds 125°F (51.70C). 13. Refrigerant Filter Drier-Biflow A device for removing contaminants from refrigerant circulating in a heat pump system; two direction flow for heat pumps. SUGGESTED USE: All field connected split system heat pumps. 13 14. Support Feet Four stick -on plastic feet which raise the unit 4 inches above the mounting pad. This allows sand, dirt and other debris to be flushed from the unit base; minimizes) corrosion. t� SUGGESTED USE: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. 15. Snow Rack Coated wire rack which supports unit 18 inches above mounting pad to allow for drainage from unit base. SUGGESTED USE: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. UNITED TECHNOLOGIES Carrier Corporation • Syracuse, New York 13221 10-89 CARRIER Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 1 4 Page 14 Catalog No. 523-872 Printed in U.S.A. PC101 Form 38YK-2PD - (i Tab 5a Sa Replaces: 38YK-1 PD • • DETAILED COOLING CAPACITIES' Evaporator Air CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM E W B Capacity MBtuh Total System KW- Capacity MBtuh Total System KW" Capacity MBtuh Total System KW" Capacity MBtuh Total System KW" Total Sens Total Sens Total Sens Total Sens 38YK060-00 Outdoor Section With 48OB005 & 315016-402 Indoor Sec ion Size 72 66.4 32.9 6.18 62.9 31.7 6.62 59.4 30.5 7.04 55.9 29.2 -7.45 1800 67 60.5 42.2 6.02 57.3 40.9 6.42 54.1 39.6 6.81 50.8 38.3 7.18 0.98 62 55.1 51.0 5.86 52.3 49.7 6.23 49.3 48.1 6.60 46.5 46.4 6.94 57 53.6 53.6 5.81 51.3 51.3 6.20 48.9 48.9 6.57 46.4 46.4 6.94 7/8 72 67.2 34.2 6.31 63.7 32.9 6.75 60.1 31.7 7.18 56.4 30.4 7.59 2000 67 61.3 44.3 6.15 58.0 43.0 6.56 54.7 41.7 6.95 51.13 40.4 7.32 62 56.0 53.9 5.99 53.2 52.4 6.38 50.3 50.3 6.75 47.7 47.7 7.13 57 55.2 55.2 5.97 1 52.8 52.8 6.37 1 5.03 50.3 6.75 47.7 47.7 7.13 72 67.9 35.4 6.43 64.2 34.1 6.88 1 60.6 32.8 7.31 56.9 31.6 7.72 2200 67 61.9 46.6 6.27 58.6 1 45.1 6.68 55.1 1 43.7 7.08 51.7 42.4 7.46 62 57.0 56.5 6.12 54.2 54.2 6.52 51.5 51.5 6.92 48.9 48.9 7.30 57 56.7 56.7 6.12 54.1 54.1 6.52 51.5 51.5 6.92 48.9 48.9 7.30 'Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25 feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. tTotal and sensible capacities are net capacities. Blower motor heat has been subtracted. $Sensible capacities shown are based on 80 F entering air at the indoor coil. For sensible capacities at other than 80 F, deduct 835 Btuh per 1000 Cfm of indoor coil air for each degree below 80 F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80 F. "System KW is total of indoor and outdoor unit KW's. EWB = Entering Wet Bulb. HEAT PUMP HEATING PERFORMANCE 38YK018-00/ Indoor Coil Airflow EDB OUTDOOR COIL ENTERING AIR TEMPERATURE F 401Q025 Cfm • 675 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity (MBtuh) 6.01 7.88 10.1 12.6 15.6 19.0 23.0 27.4 Integrated Capacity (MBtuh)t 5.53 7.24 9.17 11.2 14.2 19.0 23.0 27.4 Total Power Input (KW)$ 1 1.44 1.55 1.66 1.78 1.91 2.07 2.25 2.47 Multioliers for Determinino the Performance With Other Indoor Sections Indoor Section Size muni nerS Tor uetermininq ine verTormance wan Viner m000r JecuonS Size Heating Capacity Indoor Section Size Co linq Capacity Power 1.06 Indoor Section Size Cooling Capacity Power 28RD/RN 057 0.92 0.94 40QB/QH 400B 160 0.98 1.02 025 1.00 060 0.96 0.95 030 1.00 40QB/QH 060 0.93 1.00 061 1 0.96 0.95 062 0.94 0.98 28RH 060 0.92 0.94 063 0.97 0.99 28SL 061 0.97 0.95 1.03 400B + 315016-402 005 1.00 1.00 15.00 18.00 'Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25 feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. tTotal and sensible capacities are net capacities. Blower motor heat has been subtracted. $Sensible capacities shown are based on 80 F entering air at the indoor coil. For sensible capacities at other than 80 F, deduct 835 Btuh per 1000 Cfm of indoor coil air for each degree below 80 F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80 F. "System KW is total of indoor and outdoor unit KW's. EWB = Entering Wet Bulb. HEAT PUMP HEATING PERFORMANCE 38YK018-00/ Indoor Coil Airflow EDB OUTDOOR COIL ENTERING AIR TEMPERATURE F 401Q025 Cfm • 675 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity (MBtuh) 6.01 7.88 10.1 12.6 15.6 19.0 23.0 27.4 Integrated Capacity (MBtuh)t 5.53 7.24 9.17 11.2 14.2 19.0 23.0 27.4 Total Power Input (KW)$ 1 1.44 1.55 1.66 1.78 1.91 2.07 2.25 2.47 Multioliers for Determinino the Performance With Other Indoor Sections Indoor Section Size Heating Capacity Power Indoor Section Size Heating Capacity Power 28RD/RN 018 0.95 1.06 28HO 024 0.99 1.03 67 019 0.99 1.03 40QB/QH 024 1.00 1.04 024 0.99 1.03 025 1.00 1.00 28RH 018 0.95 1.06 030 1.00 1.05 Total Power Input (KW)$ 024 0.99 1.03 40RC 018 0.97 1.01 28RM 024 0.98 1.04 1 024 0.99 1.04 38YK024-00/ Indoor Coil Airflow Heating Capacity EDB Indoor Section OUTDOOR COIL ENTERING AIR TEMPERATURE F Heating Capacity Power 40AQ031 I Cfm* 900 0.97 700 -3 7 17 27 37 47 57 67 Instantaneous Capacity (MBtuh) 9.59 12.2 15.1 18.4 22.2 26.5 32.0 37.9 Integrated Capacity (MBtuh)t 8.83 11.2 13.7 16.3 20.2 26.5 32.0 37.9 Total Power Input (KW)$ 1.83 1.96 2.09 2.23 2.37 2.54 2.76 3.02 1.02 Multioliers for Determinino the Performance With Other Indoor Sections 030 0.98 1.02 28RM Indoor Section Size Heating Capacity Power Indoor Section Size Heating Capacity Power 28RD/RN 024 0.97 1.03 28SL 030 0.97 1.01 025 0.97 1.03 40A0 030 0.98 1.00 130 0.98 1.00 031 1.00 1.00 28RD 030 0.98 1.00 036 0.98 1.01 28RH 024 0.97 1.03 40RC 024 0.98 1.02 030 0.98 1.00 030 0.98 1.02 28RM 024 0.97 1.03 28HO 030 0.98 1.00 See notes on page 12. 10 Model number nomenclature i!• Physical data 3 0 0 Packaging Series Electrical 3 - 208/230-1 MODEL 38YK 38YK 018 • 1 030-00 1 036-00 1 042-00 Electric Heat Pump 060-00 Nominal Capacity Heat Pump 036 - 36,000 Btu 018 - 18,000 Btu 042 - 42,000 Btu 024 - 24,000 Btu 048 - 48,000 Btu 030 - 30,000 Btu 060 - 60,000 Btu i!• Physical data 3 0 0 Packaging Series Electrical 3 - 208/230-1 MODEL 38YK 018-00 1 024-00 1 030-00 1 036-00 1 042-00 048-00 060-00 REFRIGERANT Heat Pump Outdoor 22 Control Piston TXV' TXV (Cooling) 018-00 Charge (Ibs) 6.75 1 9.75 1 8.75 1 .38 1 9.75 12.75 15.75 COND FAN Propeller Type, Direct Drive 61 315175-76101 Air Discharge • 036-00 Vertical 315175-76101 + Air Qty (Cfm) 042-00 2600 1 3000 3800 COND COIL 67 315175-76201 060-00 Face Area (sq ft) 315175-76401 15.00 18.00 24.50 CONNECT. (in. ID) Sweat Vapor 5/8 3/4 I 7/8 Liquid 3/8 REFRIG TUBES' (in. OD) Vapor 5/8 3/4 1-1/8 Liquid 3/8 OPER. WEIGHT (Ibs) 194 249 251 253 257 275 361 NOTE: See unit Installation Instructions for proper installation. 'Tube sizes are for runs up to 50 ft. For tube set over 50 ft, consult long tube information. `pt,fED TO,y� �''EOE.wTE f 9q'7TAN[Alko t 3 Metering device device Heat Pump Outdoor Indoor Size Piston TXV' 018-00 42 315175-75901 024-00 49 315175-76001 030-00 61 315175-76101 • • 036-00 59 315175-76101 + 042-00 63 315175-76201 048-00 67 315175-76201 060-00 82 315175-76401 'TXV listed is for any approved coil combination. All TXV's are bi-flow. t 3 Dimensions ; AIR AIR U AIR DI: 3/8-D. (9.5) KNOCKOUTS t�_ E A89396 UNIT SERIES A 8 C D E F G H K SIZE (IN.) . (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) (IN.) (mm) 018 00 31-7/8" 809.6 30" 762.0 34.15/16" 887.3 4" 101.6 9-3/4" 247.6 21-1/2" 546.1 27-7/8" 708.0 5/8" 15.88 8.3/16" 207.9 024 00 31-7/8" 809.6 30" 762.0 34-15/16" 887.3 4" 101.6 9.3/4" 247.6 21-1/2" 546.1 27-7/8" 708.0 3/4" 19.05 8-3/16" 207.9 030 00 31-7/8" 809.6 30" 762.0 34-15/16" 887.3 4" 101.6 9-3/4" 247.6 21-1/2" 546.1 27-7/8" 708.0 3/4" 19.05 8-3/16" 207.9 036 00 31.7/8" 809.6 30" 762.0 34-15/16" 887.3 4" 101.6 9-3/4" 247.6 21-1/2" 546.1 27.7/8" 708.0 3/4" 19.05 8-3/16" 207.9 • 042 00 31-7/8" 809.6 30" 762.0 34-15/16" 887.3 4" 101.6 9-3/4" 247.6 21.1/2" 546.1 27-7/8" 708.0 7/8" 22.22 8-3/16" 207.9 048 00 37-7/8" 962.0 30" 762.0 34-15/16" 887.3 4" 101.6 9.3/4" 247.6 27-1/2" 698.5 33-7/8" 860.4 7/8" 1 22.22 8-3/16" 207.9 060 00 1 37.7/8" 1962.01 38-5/8" 1 981.0 45" 1 1143. 5-15/16" 1 150.8 11-13/16" 300.0 27-1/2" 1 698.5 33-7/8" 860.4 7/8" 1 22.22 8-9/16" 1 217.4 Accessories ORDERING NUMBER _ DESCRIPTION ORDERING NUMBER DESCRIPTION 32LT660004 Motormaster Controller Sizes 024-060'$ 313074-751 Outdoor Thermostat HC36GE230 Low Ambient Motor Size 024-030$ 313074-752 Secondary Outdoor Thermostat HC40GE230 Low Ambient Motor Sizes 036-048$ 313076-751 Service Sentryt HC38GE230 Low Ambient Motor Size 060$ 3BYH900051 Optimizer II HN67XZ210 Winter Start Control$ 313079-751 High Pressure Switch -All Sizes HH22UA025 Evaporator Freeze Thermostat$ P504 -8083S Refrigerant Filter Drier-Biflow (New Construction) HN61 KK066 Isolation Relay$ P504 -8163S Refrigerant Filter Drier-Biflow (Add-on or Replacement) 313909-751 Time Guard'N' II 38TH900011 Four Support Feet -4 in. Standard Start Capacitor and Relay Size 018-060 3BYH900011 Snow Rack -Sizes 018-048 312991-751 Sound Blanket 018 Size 38YH900021 Snow Rack -Size 060 Standard Sound Blanket 024-060 Sizes 4.06 36.6 'Low Ambient motor required. tFor indicator light function, thermostat specified must be used $Consult Low Ambient Installation Instructions for application. •0 DETAILED COOLING CAPACITIES' Evaporator Air _ CONDENSER:ENTERING AIR TEMPERATURES F 85 95 105 115 CFM E W, B Capacity MBtuht Total System KW • • Capacity MBtuht Total System KW' • CapacityTotal MBtuht System KW' • Capacity MBtuht Total System KW Total Sens$ Total Sens$ Total Sens$ Total Sens$ 38YK042-00 Outdoor Section With 40QB/QH049 Indoor Section-- - --" Multipliers for Determininq the Performance With Other Indoor Sections Indoor Section 72 47.4 23.8 4.24 44.9 22.9 4.60 42.2 --22.0 4.94 39:6 "21".1- -5.28 1400 67 43.1 30.6 4.16 40.7 29.6 4.49 38.3 28.7 4.82 35:8 27.7 5.13 28RD/RN 62 39.3 37.0 4.08 37.1 35.9 4.39 34:9 34.6 4.70 33.0 33.0 --5.00 060 0.98 0.95 57 38.4 38.4 4.06 36.6 36.6 4.38 34.8 34.8 4.69 33.0 33.0 5.00 248 0.99 1 0.97 72 48.1 24.8 4.34 45.4 23.9 4.69 42.6 22.9 5.04 39.9 22.0 5.38 1575 67 43.7 32.3 4.26 41.2 31.3 4.59 38.7 30.3 4.92 36.2 29.4 5.23 62 40.1 39.2 4.18 37.9 37.8 4.50 35.9 35.9 4.82 34.0 34.0 5.14 57 39.7 39.7 4.17 37.8 37.8 4.50 35.9 35.9 4.82 33.9 33.9 5.14 72 48.6 25.7 4.42 45.8 24.8 4.79 43.0 23.8 5.14 40.2 22.9 5.48 1750 67 442 33.9 4.35 41.6 32.9 4.68 39.1 .31.9 5.01 36.5 30.9 5.33 62 40.8 40.7 4.28 38.8 38.8 4.61 36.8 36.8 4.94 34.7 34.7 5.26 57 40.8 40.8 4.28 38.8 38.8 4.61 36.8 36.8 4.94 34.7 34.7 5.26 Multipliers for Determininq the Performance With Other Indoor Sections Indoor Section Size Cooling Capacity Power Indoor Section Size Cooling Capacity Power 28HONG 048 0.95 0.96 28RH 042 0.94 0.96 28RD 048 0.96 0.96 048 0.96 0.96 34.5 049 1.00 0.97 28RM 048 0.96 0.96 28RD/RN 042 0.94 0.96 28SL 042 0.95 0.96 142 0.94 0.96 049 0.99 0.97 043 1.00 0.97 042 0.96 0.97- .97-143 060 0.98 0.95 143 1.00 0.97 40QB/0H 043 0.98 0.99 242 0.99 0.97 048 0.98 0.99 148 0.96 0.96 049 1.00 1.00 248 0.99 1 0.97 72 56.2 38YK048-00 Outdoor Section With 40QB/QH063 Indoor Section MUILpIIers for Determining the Performance With Other Indoor Sections Indoor Section 72 55.6 27.8 5.06 52.4 26.6 5.48 49.2 25.5 5.89 46.1 24.4 6.29 1600 67 50.4 35.6 4.96 47.5 34.5 5.35 44.6 33.4 4.73 41.8 32.2 6.10 148 0.94 0.93 62 45.8 43.2 4.86 43.3 41.9 5.23 40.8 40.4 5.59 38.5 38.5 5.95 060 0.98 0.95 57 44.9 44.9 4.84 42.8 42.8 5.21 40.6 40.6 5.58 38.5 38.5 5.95 72 56.2 28.9 5.18 53.0 27.8 5.61 49.8 26.7 6.02 46.6 25.6 6.42 1800 67 51.1 37.6 5.08 48.2 36.5 5.48 45.2 35.3 5.86 42.2 34.2 6.24 62 46.8 45.8 4.99 44.3 44.2 5.37 41.9 41.9 5.75 39.7 39.7 6.12 57 46.4 46.4 1 4.98 1 44.2 1 44.2 1 5.36 1 41.9 41.9 5.75 1 39.6 1 39.6 1 6.12 72 56.7 30.0 5.30 53.5 28.9 5.73 50.3 27.8 6.15 46.9 26.6 6.55 2000 67 51.6 39.6 5.20 48.6 38.4 5.60 45.5 37.2 5.99 42.5 36.1 6.37 62 47.6 47.6 5.12 1 45.3 1 45.3 5.51 43.0 43.0 5.90 40.6 40.6 6.28 57 47.7 47.7 5.12 45.3 45.3 5.51 43.0 43.0 5.90 40.6 40.6 6.28 MUILpIIers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Capacity Power Indoor Section Size Cooling Capacity Power 28HONO 060 0.96 0.93 28RM 048 0.93 0.92 28RD 048 0.94 0.93 28SL 049 0.96 0.94 049 0.97 0.94 061 0.99 0.95 28RD/RN 148 0.94 0.93 048 0.94 0.96 248 0.95 0.93 049 0.97 1.00 057 0.97 0.94 40QB/QH 060 0.96 0.96 060 0.98 0.95 062 0.97 1.01 061 1.00 0.95 063 1.00 0.99 28RH 048 0.94 1 0.93 060 0.97 1 0.94 See notes on page 10. 4 9 DETAILED COOLING CAPACITIES' Evaporator CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 Air - Power E Capacity Total Capacity Total Capacity Total Capacity Total CFM W. MBtuht System MBtuht System MBtuht System MBtuht System Total Sens Total Sens Total Sens Total Sens 40AO B KW" KW" KW" KW" 38YK030-00 Outdoor Section With 40A0031 Indoor Section 030 72 33.7 16.7 2.87 31.9 16.1 3.11 30.0 15.4 3.36 28.1 14.7 3.60 1000 67 30.6 21.2 2.82 28.9 20.6 3.05 27.2 19.9 3.28 25.4 19.2 3.50 19.3 62 27.7 25.6 2.77 26.2 24.8 2.99 24.7 24.0 3.20 23.2 23.0 3.42 25.7 57 26.9 26.9 2.76 25.6 25.6 2.98 24.4 24.4 3.20 23.1 23.1 3.42 29.7 72 34.2 17.4 2.93 32.3 16.7 3.18 30.4 16.0 3.42 28.5 15.4 3.66 1125 67 31.0 22.4 2.88 29.3 21.7 3.12 27.5 21.0 3.34 25.7 20.3 3.57 27.1 62 28.3 27.0 2.84 26.7 26.2 3.06 25.2 25.2 3.28 23.8 23.8 3.50 30.5 57 27.8 27.8 1 2.83 1 26.5 26.5 3.05 1 25.2 25.2 3.28 23.8 23.8 3.50 30.5 72 34.6 18.0 2.99 32.6 17.3 3.24 30.7 16.6 3.48 28.7 16.0 3.73 1250 67 31.4 23.5 2.94 1 29.6 1 22.7 3.18 27.8 22.0 3.41 26.0 21.3 3.63 62 28.8 28.3 2.90 27.2 27.2 3.12 25.8 25.8 3.35 24.5 24.5 3.58 23,800 57 28.6 28.6 2.90 27.2 27.2 3.12 25.8 1 25.8 3.35 24.5 24.5 3.58 Multinliers for Determinino the Performance With Other Indoor Sections Indoor Section Size Co ling Capacity Power Indoor Section Size Cooling Capacity Power 28HO/V0 036 0.99 0.98 28RM 036 0.97 0.98 28RD 136 1.01 0.99 28SL 030 0.96 0.98 !' 28RD/RN 130 0.99 0.97 036 0.99 0.99 UNIT 030 0.99 0.97 40AO 031 1.00 1.00 036 1.01 1 0.99 036 0.98 0.99 28RH 030 0.99 0.97 40RC 030 0.97 1.00 036 1.01 0.99 32.0 3.83 39YK036-00 Outdoor Section With 40013/01-1043 Indoor Section MUItiDliers for Determinina the Performance With Other Indoor Sections -Indoor Section 72 41.6 20.9 3.67 39.3 20.1 3.99 37.0 19.3 4.31 34.7 18.5 4.62 1200 67 37.7 26.7 3.61 35.6 25.9 3.92 33.5 25.0 4.21 31.4 24.2 4.50 UNIT 62 34.3 32.2 3.56 32.4 31.3 3.84 30.5 30.2 4.12 28.8 28.8 4.40 1.00 57 33.5 33.5 3.54 32.0 32.0 3.83 30.4 30.4 4.12 28.8 28.8 4.40 75 72 42.2 21.8 3.74 39.8 21.0 4.07 37.5 20.2 4.39 35.1 19.3 4.70 1350 67 38.3 28.2 3.68 36.2 27.4 3.99 34.0 26.5 4.29 31.7 25.7 4.58 135.0 62 35.0 34.1 3.63 33.1 33.0 3.93 31.4 31.4 4.22 29.7 29.7 4.50 2.76 57 34.6 34.6 3.63. 33.0 33.0 3.92 31.4 31.4 4.22 29.7 28.7 4.50 1500 67 38.8 29.7 3.76 36.5 28.8 4.07 34.3 27.9 4.37 32.0 27.1 4.66 40RC018 62 35.7 35.6 3.71 33.9 33.9 4.01 32.2 32.2 4.31 30.5 30.5 4.60 9.50 57 35.7 35.7 3.71 34.0 34.0 4.01 32.2 32.2 4.31 30.5 30.5 4.60 MUItiDliers for Determinina the Performance With Other Indoor Sections -Indoor Section Size Cooling Capacity Power Indoor Section Size Cooling Capacity Power 28HONO 042 0.96 0.98 28RH 036 0.96 0.97 28RD 136 0.96 0.97 042 0.96 0.98 28RD/RN 036 0.96 0.97 28RM 036 0.93 0.98 UNIT 042 0.96 0.98 28SL 036 0.95 0.98 142 0.95 0.98 042 0.96 0.98 Cfm 043 1.00 1.00 4006/0H 042 0.97 0.99 143 1.00 0.99 043 1.00 1.00 242 0.99 0.99 82.0 22.4 See notes on page 10. 0-0 THERMOSTAT/SUBBASE PKG. HH07AT175 HH07AT165 HH93AZ195 HH93AZ196 HH07AE001 Electrical data DESCRIPTION Thermostat-Auto/Manual OF Thermostat-Auto/Manual °C Subbase -Manual Subbase -Auto Night Setback (Includes thermostat and subbase) OF OUTDOOR UNIT 38YK V/PH 60 Hz OPER VOLTS' COMPR FAN MCA MIN. WIRE SIZE** MAX. LENGTH (Ft. )$ MAX FUSEL OR HACR TYPE CKT BKR AMPS Max Min LRA RLA FLA 018-300 49.0 9.1 0.9 12.3 14 75 20 024-300 Seasonal Sound UNIT 53.0 13.4 0.9 17.6 12 80 30 030-300 r ? 38YK Cfm 65.0 15.3 0.9 20.0, 12 70 35 036-300 208/230/1 253 187 82.0 22.4 1.4 29.4 10 75 50 042-300 28RD/RN019 650 106.0 22.7 1.4 29.8 10 75 50 048-300 28RHO18 650 127.0 25.5 1.4 33.3 8 110 50 060-300 28HQ024 650 135.0 28.9 1.4 37.5 8 95 60 FLA -Full Load Amps HACR-Heating, Air Conditioning, Refrigeration LRA -Locked Rotor Amps MCA -Minimum Circuit Amps RLA -Rated Load Amps 'Permissible limits of the voltage range at which unit will operate satis- factorily. tTime-delay fuse. #Length shown is as measured one way along the wire path between the unit and the service panel for minimum 2% voltage drop. Combination Ratings NOTE: Control circuit is 24 v on all units and requires external power source. If other than 60 C copper wire is used, size can be determined from unit ampacity given in above table and applicable table of National Electric Code. Wire size selected must have current capacity not less than that of copper wire specified and must not create a volt- age drop between service panel and unit in excess of 2% of unit rated voltage. Must use copper wire from disconnect to unit. See notes on page 7. 8 5 ARI STANDARD RATINGS' Cooling Heating Seasonal OUTDOOR INDOOR Efficiency . HI -Temp Lo -Temp Seasonal Sound UNIT UNIT With Efficiency Rating r ? 38YK Cfm TC TXV HSPF (Bels) TC COP TC COP' 28RD/RN018 650 17,800 9.80 18,000 2.56 9,900 1.92 6.30 7.6 28RD/RN019 650 18,400 10.10 18,800 2.76 10,000 1.98 6.50 7.6 28RHO18 650 17,800 9.80 18,000 2.56 9,900 1.92 6.30 7.6 28HQ024 650 18,000 9.80 18,800 2.76 10,000 2.00 6.60 7.6 28RD/RN024 650 18,400 10.10 18,800 2.76 10,000 1.98 6.50 7.6 018-00 28RHO24 650 18,400 10.10 18,800 2.76 10,000 1.98 6.50 7.6 28RM024 650 18,100 10.00 18,500 2.70 10,000 1.98 6.50 7.6 40RC018 650 18,200 10.00 18,300 2.74 9,900 2.02 6.60 7.6 40A0024 650 18,000 9.50 18,900 2.76 10,100 1.98 6.60 7.6 40AQ025t 650. 18,500 10.00 18,900 2.86 10,000 2.00 6.75 7.6 40RCO24 650 18,500 10.00 18,700 2.72 10,100 2.00 " 6.60 7.6 40AQ030 650 18,700 10.00 18,900 2.72 10,200 2.00 6.60 7.6 28RD/RN024 875 23,400 10.00 25,600 3.00 14,900 2.08 6.90 7.6 28RD/RN025 875 23,800 10.10 25,600 3.00 14,900 2.08 6.90 7.6 28RHO24 875 23,400 10.00 25,600 3.00 14,900 2.08 6.90 7.6 28RM024 875 23,400 10.00 25,600 2.98 14,800 2.08. 6.90 7.6 28HQ030 875 23,800 10.00 26,000 3.12 15,000 2.12 7.10 7.6 28RD030 875 24,000 10.20 26,000 3.12 15,100 2.14 7.20 7.6 024-00 28RD/RN130 875 24,000 10.20 26,000 3.12 15,100 2.14 7.20 7.6 28RHO30 875 24,000 10.20 26,000 3.12 15,100 2.14 7.20 7.6 28SLO30 875 23,400 10.00 25,600 3.06 15,000 2.12 7.00 7.6 40RCO24 875 23,200 10.00 25,800 3.06 15,000 2.10 7.00 7.6 40AQ030 875 23,200 10.00 25,800 3.10 15,000 2.10 7.00 7.6 40A0031 t 875 24,000 10.30 26,400 3.18 15,000 2.14 7.20 7.6 40RC030 875 23,000 10.00 26,000 3.06 15,200 2.10 7.00 7.6 40A0036 1 875 1 23,600 1 10.00 1 26,000 1 3.10 1 15,000 2.10 7.00 1 7.6 See notes on page 7. 8 5 Combination Ratings cont'd See notes on page 7. M Nr, • Combination Ratings cont'd OUTDOOR UNIT 38YK INDOOR ' ` UNIT ARI STANDARD RATINGS' Sound `' Cfm Cooling Heating TC Seasonal Efficiency- With• - TXV _HkTemp- L_o_-T_e_mp Seasonal ,_ - - - - rRating (Bels) TC - - - OUTDOOR INDOOR 060-00 40QB/QH060 40QB/QH062 40QB/QH063 40QB005 and 315016-402t 4008160 Efficiency HI -Temp Lo-Tetnp_ -Seasonal' -Sound UNIT UNIT 7.20 7.20 " 7.30 7.50 7.30 8.0 8.0 8.0 8.0 8.0 With 16.5 15.7 Efficiency Rating TC COP TC COP 38YK 0.99 CIM TC TXV HSPF (Bels) 16.2 28RD030 1000 28,800 10.20 30,000 3.08 17,000 2.16 7.00 7.6 11.1 28RD/RN130 1000 28,800 10.20 30,000 3.08 17,000 2.16 7.00 7.6 675 28RHO30 1000 28,800 10.20 30,000 3.08 17,000 2.16 7.00 7.6 16.2 28SLO30 1100 28,000 10.00 30,000 3.04 17,100 2.12 6.90 7.6 15.9 28HQN0036 1100 28,800 10.10 30,600 3.14 17,200 2.16 7.10 7.6 16.8 28RD/RN036 1100 29,400 10.30 30,800 3.16 17,300 2.18 7.20 7.6 030-00 28RD136 1100 29,400 10.30 30,800 3.16 17,300 2.18 7.20 7.6 2.50 28RHO36 1100 29,400 10.30 30,800 3.16 17,300 2.18 7.20 7.6 2.30 28RM036 1100 28,400 10.10 30,000 3.02 17,100 2.12 7.00 7.6 2.13 28SLO36 1100 29,000 10.20 30,600 3.10 17,300 2.18 7.10 7.6 2.01 40AQ031t 1100 29,200 10.30 31,000 3.10 17,200 2.14 7.20 7.6 40RC030 1100 28,400 10.00 30,600 3.04 17,400 2.12 6.90 7.6 40A0036 1100 28,600 10.00 1 30,600 3.10 17,300 1 2.14 7.00 7.6 28RD/RN036 1200 34,400 10.00 36,400 3.00 22,000 2.14 7.00 7.8 28RD136 1200 34,400 10.00 36,400 3.00 22,000 2.14 7.00 7.8 28RHO36 1200 34,400 10.00 36,400 3.00 22,000 2.14 7.00 7.8 28RM036 1300 33,400 9.60 36,000 2.80 22,000 2.10 6.85 7.8 28SLO36 1300 34,200 9.50 36,800 2.88 22,200 2.14 7.00 7.8 28HOlVO042 1300 34,400 9.80 37,000 3.06 22,200 2.16 7.00 7.8 036-00 28RD/RN042 1300 34;400 9.90 36,600 3.00 22,200 2.14 7.00 7.8 28RD/RN142 1300 34,200 9.80 36,800 3.00 22,200 2.14 7.00 7.8 28RD/RN043 1300 36,000 10.00 37,000 3.12 22,400 2.20 7.20 7.8 28RD/RN143 1300 36,000 10.00 37,000 3.10 22,400 2.20 7.20 7.8 28RD/RN242 1300 35,800 10.00 36,800 3.04 22,200 2.16 7.00 7.8 28RHO42 1300 34,400 9.90 36,600 3.00 22,200 2.14 7.00 7.8 28SLO42 1300 34,400 9.80 36,800 3.00 22,200 2.14 7.00 7.8 40QB/QH042 1300 35,000 10.00 37,500 3.14 22,600 2.18 7.00 7.8 4008/01-1043t 1300 36,000 10.00 1 38,000 3.16 22,600 1 2.20 7.30 7.8 28RD/RN042 1500 38,500 9.70 41,500 3.00 25,800 2.20 7.20 7.8 28RD/RN142 1500 38,500 9.60 41,500 3.00 25,800 2.20 7.10 7.8. 28RD/RN043 1500 41,000 10.00 42,000 3.08 26,000 2.20 7.30 7.8 28RD/RN143 1500 41,000 10.00 42,000 3.06 26,000 2.20 7.30 7.8 28RD/RN242 1500 40,500 10.00 41,500 3.00 25,800 2.20 7.20 7.8 28RHO42 1500 38,500 9.70 41,500 3.00 25,800 2.20 7.20 7.8 28SLO42 1500 39,000 9.70 41,500 3.00 25,800 2.20 7.00 7.8 28HONQ048 1500 39,000 9.70 42,000 3.02 25,800 2.20 7.20 7.8 28RD048 1500 39,500 9.90 42,500 3.06 26,000 2.20 7.30 7.8 042-00 28RD/RN148 1500 39,500 9.90 42,500 3.06 26,000 2.20 7.30 7.8 28RD049 1500 41,000 10.00 42,500 3.12 26,000 2.22 7.30 7.8 28RD248 1500 40,500 10.00 42,000 3.04 26,000 2.20 7.30 7.8 28RHO48 1500 39,500 9.90 42,500 3.06 26,000 2.20 7.30 7.8 28RM048 1500 39,500 9.90 42,000 3.00 26,000 2.20 7.20 7.8 28SLO49 1500 40,500 10.00 42,000 3.08 26,000 2.20 7.30 7.8 40QB/QH042 1500 39,500 9.60 42,500 3.08 26,200 2.20 7.30 7.8 40QB/QH043 1500 40,000 9.80 42,500 3.12 26,200 2.22 7.30 7.8 40QB/QH048 1500 40,000 9.60 42,000 3.10 26,600 2.20 7.10 7.8 40QB/QH049t 1500 41,000 10.00 1 43,000 3.10 26,600 1 2.20 7.30 7.8 28RD048 1750 45,000 9.80 47,000 3.00 28,600 2.20 7.20 8.0 28RD/RN148 1750 45,000 9.80 47,000 3.00 28,600 2.20 7.20 8.0 28RD049 1750 46,500 10.00 47,000 3.04 28,400 2.20 7.20 8.0 28RD248 1600 45,500 10.00 46,000 2.94 28,000 2.18 7.00 8.0 28RHO48 1750 45,000 9.80 47,000 3.00 28,600 2.20 7.20 8.0 28RM048 1600 44,500 9.80 46,000 2.90 28,200 2.18 7.00 8.0 28SLO49 1750 46,000 10.00 46,500 3.00 28,400 2.20 7.10 8.0 28HONQ060 1600 46,000 10.00 47,500 3.06 28,600 2.20 7.20 8.0 048-00 28RD/RN057 1750 46,500 10.00 47,000 3.04 28,400 2.20 7.20 8.0 28RD/RN060 1750 47,000 10.00 48,000 3.10 29,000 2.20 7.30 8.0 28RD/RN061 1750 48,000 10.00 47,500 3.10 28,600 2.20 7.30 8.0 28RHO60 1750 46,500 10.00 47,000 3.04 28,400 2.20 7.20 8.0 28SLO61 1750 47,500 10.00 47,500 3.10 28,800 2.20 7.30 8.0 40QB/QH048 1750 45,000 9.70 48,000 3.10 29,000 2.20 7.30 8.0 40OB/QH049 1750 46,500 9.80 47,500 3.06 29,000 2.20 7.10 8.0 40QB/QH060 1750 46,000 9.50 47,500 3.06 29,600 2.16 7.10 8.0 4008/01-1062 1750 46,500 9.50 47,500 3.10 29,600 2.20 7.10 8.0 4008/QH063t 1750 48,000 10.00 1 48,000 3.10 29,600 1 2.20 7.30 8.0 28RD/RN057 2000 53,500 9.70 58,000 3.00 34,200 2.28 7.20 8.0 28RD/RN060 2000 55,500 9.90 58,500 3.06 35,000 2.30 7.20 8.0 060-00 28RD/RN061 2000 55,500 10.00 58,500 3.08 34,400 2.30 .7.20 8.0 28RHO60 2000 53,500 9.70 58,000 3.00 34,200 2.28 7.20 8.0 28SLO61 2000 56,500 10.00 59,000 3.10 34,600 2.30 7.20 8.0 See notes on page 7. M Nr, • Combination Ratings cont'd OUTDOOR UNIT 38YK INDOOR ' ` UNIT ARI STANDARD RATINGS' Sound `' Cfm Cooling Heating TC Seasonal Efficiency- With• - TXV _HkTemp- L_o_-T_e_mp Seasonal ,_ - - �- Efficiency_ HSPF rRating (Bels) TC COP TC COP 060-00 40QB/QH060 40QB/QH062 40QB/QH063 40QB005 and 315016-402t 4008160 2000 2000 2000 2000 2000 54,000 54,500 56,000 58,000 1 56,500 9.00 9.30 9.80 10.00 10.00 61,000 61,000 60,000. 61,000 60,000 3.00 3.06 3.06 3.20 3.10 36,200 35,800 35,600 36,000 1 35,000 2.22 2.26 2.28 2.30 1 2.30 7.20 7.20 " 7.30 7.50 7.30 8.0 8.0 8.0 8.0 8.0 COP-coetticlent of Pertormance Tc - I otal capacity (utuh) HSPF-Heating Seasonal Performance Factor 'Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: f Cooling Standard: 80 F db 67 F wb indoor entering air temperature and 95 F db air entering outdoor unit. r, HI -Temp Heating Standard: 70 F db indoor entering air temperature and 47 F db 43 F wb air entering outdoor unit. Lo -Temp Heating Standard: 70 F db indoor entering air temperature and 17 F db 15 F wb air entering outdoor unit. tOutdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined under l+ DOE computer simulation procedures. DETAILED COOLING CAPACITIES' 00 1 ir 00 38YK019-00 Outdoor Section With 40A0025 Indoor Section Evaporator Air CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 CFM E W B MB CapRiid Total System Capacity MBtuht Total System KW" Capacity MBtuht Total System KW-- Capacity MBtuht Total System KW• TotalKW' Total Sens# Total I Sens# Total I Sens# 00 1 ir 00 38YK019-00 Outdoor Section With 40A0025 Indoor Section Multipliers for Determinina the Performance With Other Indoor Sections Indoor Section 72 21.5 10.7 2.04 20.3 10.3 2.16 19.1 9.82 2.29 17.8 9.38 2.41 600 67 19.4 13.5 1.98 18.3 13.1 2.09 17.1 12.6 2.22 16.0 12.1 2.33 018 0.96 0.96 62 17.6 16.2 1.92 16.5 15.7 2.03 15.5 15.2 2.15 14.5 14.5 2.27 0.99 57 17.0 17.0 1.90 16.2 16.2 12.02 15.4 15.4 2.14 14.5 14.5 2.27 72 21.9 11.1 2.08 20.6 10.7 2.21 19.3 10.2 2.33 18.0 9.81 2.46 675 67 19.8 14.3 2.02 18.6 13.8 2.14 17.4 13.4 2.26 16.2 12.9 2.38 62 18.0 17.2 1.96 16.9 16.7• 2.08 15.9 15.9 2.20 15.0 15.0 2.33 57 1 17.7 1 17.7 1.96 16.8 16.8 2.08 15.9 15.9 1 2.20 15.0 15.0 1 2.32 7222.1 28.6 11.6 2.12 20.9 11.1 2.25 19.5 10.7 2.37 18.2 10.2 2.50 750 67 20.0 15.0 2.06 18.8 14.6 2.18 17.6 14.1 2.30 16.4 13.6 2.42 62 18.3 18.1 2.01 17.3 17.3 2.13 16.4 16.4 2.25 15.4 15.4 2.38 57 18.2 18.2 2.01 17.3 17.3 2.13 16.4 16.4 2.25 15.4 15.4 2.38 Multipliers for Determinina the Performance With Other Indoor Sections Indoor Section Size Cooling Capacity Power Indoor Section Size Cooling Capacity Power 28RD/RN 018 0.96 0.98 28HO 024 0.99 1.03 25.1 019 0.99 0.99 40AO 024 0.97 0.99 024 0.99 0.99 025 1.00 1.00 28RD 018 0.96 0.96 030 1.01 1.01 20.6 024 0.99 0.99 40RC 018 0.98 0.97 28RM 024 0.98 0.99 024 1.00 1 0.99 38YK024-00 Outdoor Section With 40AU031 Indoor Section Multipliers for Determininq the Performance With Other Indoor Sections Indoor Section 72 27.8 13.7 2.43 26.3 13.1 2.65 24.7 12.6 2.87 23.2 12.0 3.08 800 67 25.1 17.2 2.40 23.7 16.6 2.61 22.3 16.1 2.81 20.9 15.5 3.01 036 0.98 62 22.7 20.6 2.37 21.4 20.0 2.57 20.1 19.3 2.76 18.8 18.6 2.96 024 57 21.8 21.8 2.36 20.8 20.8 2.56 19.8 19.8 2.76 18.7 18.7 2.95 72 28.3 14.2 2.47 26.7 13.7 2.69 25.1 13.1 2.92 23.5 12.6 3.13 900 67 25.6 18.1 2.44 24.1 17.5 2.65 22.6 17.0 2.86 21.2 16.4 3.06 62 23.1 21.8 2.42 21.8 21.1 2.62 20.6 20.4 2.82 19.4 19.4 3.02 57 1 22.6 1 22.6 1 2.41 21.6 21.6 1 2.61 20.5 1 20.5 2.81 19.4 19.4 3.01 72 28.6 14.7 2.52 27.0 14.2 2.74 25.4 13.6 2.96 23.8 13.1 3.18 1000 67 25.9 19.0 2.49 24.4 18.4 2.70 22.9 17.8 2.91 21.4 17.3 3.11 62 23.6 22.9 1 2.46 22.3 22.1 2.66 21.1 21.1 2.87 19.9 19.9 2.07 57 23.3 23.3 2.46 22.2 22.2 2.66 21.1 21.1 2.87 19.9 19.9 3.07 Multipliers for Determininq the Performance With Other Indoor Sections Indoor Section Size Cooling Capacity Power Indoor Section Size Cooling Capacity Power 28RD/RN 024 0.97 0.99 28SL 030 0.97 0.99 025 0.99 0.99 40A0 030 0.97 1.00 030 1.00 0.99 031 1.00 1.00 130 1.00 0.99 036 0.98 1.01 28RH 024 0.97 10.99 40RC 024 0.97 10.99 030 1.00 0.99 030 0.96 1.01 28RM 024 0.97 0.99 28HO 030 0.98 1.00 See notes on page 10. 7 AND DON'T WORRY ABOUT COMING BACK. Installers in the busy California housing industry look for products that will save them time. The new time -saving Honeywell Y8224 thermostat uses proven, reliable technology to control the cycling rate of virtually all systems' from intermittent ignition furnaces to single stage heat pumps — without installer adjustments. That's right, no setting required. Improper settings cause callbacks which are time-consuming and nibble away at your profit margins. AVOID "BURN OUT" It's also pretty tough. It won't "burn out" the way a typical thermostat's anticipator can, causing even more lost time and profits. Y 181212141 THERMOSTAT k � t - - t• ^�X � ? < ;ta ,.—. id'. i.� �*-+�-xs. >r� "..` sit _ � ,} . QFINISN FAST WITH S]Yi[ Other features like factory -set programming, "level it to the eye" positioning, Honeywell's 1-800# for homeowner programming questions and more will help your installer get in and out fast. And avoid coming back. We designed it to look nice too. SLEEK CALIFORNIA STYLING Builders and homeowners will like the color and lines of the white Y8224 thermostat. Its slimmer profile and white case complement the contemporary decor of California's new homes. QUALITY COMPONENTS LIKE SEIKO TIMER MOVEMENT Quality and reliability are important to your customers, both builders and homeowners, and Seiko is a name recognized for producing superior timepieces. • White design complements • Easy to install in new the contemporary decor of construction. Meets California California's new homes. Title 24 requirements. • Battery clips provide option for • Color -coded heating and battery back-up. Homeowners cooling levers. can purchase and install alkaline batteries to keep the timer running in the event o1 a power failure. • Quiet operating Seiko timer stat • Quality that reflects well on you. requires less power from the timer to control the switching . q brand our customers y between the comfort setting recognize. and the energy savings setting. The Seiko timer controls a micro switch which controls the switching. SIERRA MECHANIC AL 83-580 PEACH S1_ SUITE #4 the INOIO. CA 92201 contact: 819-345-4430 Cl #315890-C20 For more information about Honeywell Y8224 thermo HONEYWELL RESIDENTIAL & BUILDING CONTROLS 1985 DOUGLAS DRIVE NORTH GOLDEN VALLEY. MN 55422 NORTHERN CALIFORNIA: (415) 370-1373 SOUTHERN CALIFORNIA: (213) 726-6036 MODELS AVAILABLE: Y8224A1019 Provides single stage heating and cooling with HEAT -OFF -COOL system switching and AUTO -FAN fan switching. Has common R. Subbase with 0 and 8 terminals tar control of dampers or heat pump changeover valves. Y8224A1035 Provides single stage heating and cooling with HEAT -OFF -COOL system switching and AUTON fan switching. Fan energies with make of both heating and cooing equipment for control of electric furnaces and fan coil units. Y8224AI001 Provides single stage heating or cooling. Does not have fan or system switching. Comes with wallplate for either heating -only or cooling -only. • Flip up decorator cover. • Factory -programmed for night- time energy savings period. Extra clips are included for one day -time setting. Honeywell HELPING YOU CONTROL YOUR WORLD ?Pex<dPe a4:z Duet San Diego, CA PRODUCT INFORMATION UL Class I Air Duct HC -25 HC -7 HC -25 (25' length) is constructed with a HC -7 (7' length) is constructed with a galva- galvanized spring steel helix wire, encap- nized spring steel helix wire, encapsulated in sulated in a 2 -ply, air -tight inner core. Thick a 2 -ply, air -tight inner core. A universal fiberglass insulation encompasses the core and male/female collar is factory attached to each a durable polyethylene vapor barrier surrounds end. Thick fiberglass insulation encompasses the entire duct. Compression packaged one the core and a durable polyethylene vapor bar - piece (25') per Duct-DispenserT" Carton, rier surrounds the entire duct. Compression (U.S. Pat. No. 4,771,884). packaged 2 pieces (14') per carton. PHYSICAL PROPERTIES I.D. Sizes 4"-10" in 1" increments 12"-20" in 2" increments All IDs are 3/8 " over sized Vapor Barrier Seamless, durable polyethylene Perm. Rating is 0.19 per ASTM E96 -A Conductance C = .19 at 750 F Resistance R = 5.2 at 75 " F (average all diameters) MAXIMUM OPERATING CONDITIONS Pressure Positive 4" W.G. Negative 1/2 " W. G. Friction Loss (See table reverse side) . Velocity 4000 feet per minute Temperature 0' F to 200' F at continuous operation ..... .._ CODES . - ..... UL 181 Air Duct Listed and labeled as a Class I Air Duct; FHC 25/50 UMC 10-1 Complies with the standards of the Uniform Mechanical Code NFPA 90A & 90B Meets requirements California Insulation Manufacturer, License #TD -1092 Specifications subject to change without notice 10 20 �MII■■■■ I/I/► 1 �M�m ����■■ /�►��'�I�I►. 111 ��■ W -4, P Aq h"q AW, ■ ►.14"RAW,INA W:►a1141.110,10EMAORI � 111 �����■■■■�����:1�■i.\���i�/����■■■� IV14M .111 ■■■■■■■tl■■■■■\��I■i �►I/■■■■��1■ :111 �����■■■■�������■■■►���������■■■� 1111 �����....�������■..�\������■■.� 1 1 1 II 1 40 60 80 100 5002 S. 38th Place 2300 S. Friebus Avenue, No. 106 F Phoenix, AZ 85040 7 2435 Gardena Avenue z 14742 Raymar Street Long Beach, CA 90806 200 Van Nuys, CA 91405 685 N. Poplar Street 3970 Home Avenue a San Diego, CA 92105 a 320 Lambert St., No. 8 9722 Alpaca Street 400 0 S. EI Monte, CA 91733 F 600 800 U `m 1000 a U �MII■■■■ I/I/► 1 �M�m ����■■ /�►��'�I�I►. 111 ��■ W -4, P Aq h"q AW, ■ ►.14"RAW,INA W:►a1141.110,10EMAORI � 111 �����■■■■�����:1�■i.\���i�/����■■■� IV14M .111 ■■■■■■■tl■■■■■\��I■i �►I/■■■■��1■ :111 �����■■■■�������■■■►���������■■■� 1111 �����....�������■..�\������■■.� 1 1 1 II 1 JPL40 12/88 2500 629 Alpine Way 5002 S. 38th Place 2300 S. Friebus Avenue, No. 106 Escondido, CA 92025 Phoenix, AZ 85040 Tucson, AZ 85713 2435 Gardena Avenue 2095 Chicago Avenue 14742 Raymar Street Long Beach, CA 90806 Riverside, CA 92507 Van Nuys, CA 91405 685 N. Poplar Street 3970 Home Avenue Orange, CA 92668 San Diego, CA 92105 320 Lambert St., No. 8 9722 Alpaca Street Oxnard, CA 93030 S. EI Monte, CA 91733 JPL40 12/88 2500 �TABLE�, S DETERMINING WATER;HEATING ENERGY CREDITS. Energy .."credits" may • be. taken,jor ��water heating, systems or., devices which: - reduce the heating load': r' Credi-"ts.-.must- be calculated using the following procedures identified,-in.'tshhi�s�.,table.and only for the devices listed. r-� �F�`§!'•�t��5'�r"t�1�{�i„F�'i'L : a. _ ' .. .: ..:: • ...r `._.ti.i,,.;..rt..,:7,h...._..+:»r.:n..�.a....•J:.,...-,..._,....� - '- Water rfieating,,energy savings-,. or, credits, are based on a fixed savings percentage '.for- each, .of,. the .identified energy saving devices; 'except solar water heating systems.-which,.calculate energy savings according to an F -chart type` solar`}analysis. - :Manufacfu`rers "of water heating energy .savings products cannot claim greater•�•savings than what the CEC allows through this method. Products which can be shown to provide greater savings may apply for consideration_as.an exceptional.method through the process described in Title 20, Section"'1409,• Exceptional Methods, of the Building Energy Efficiency Standards. 1. Identify the energy saving device(s) being used and enter the identifier on Step*Cl, of the WORKSHEET. Energy Saving Device Active solar water heati Internal wood stove boiler Identifier stem ASOLAR Passive `solar watee*heating system - 2.-----Calculate–.the -water-:--heating--energy referring to the appropriate table. Water Saving Device. Active solar water heater Hot water recovery system Internal wood stove -boiler Point of Use Passive solar water heating system WSB f5*11>F:Td savings for.- the-=device(s)- -by Table 5A 5B 5C 5D 5E 3. Regardless,.of,--,actual,. water..heat ing system design,,. edi,t.,.may only be taken for ggg device per'"dwelling unit. ; 4.,.,_,Credit-.may not . be taken,, any system. fail.ing ;toy...meet;;-all specified .,,.>instal.lation.criteria Water Heating 6-29 '. .i :.. .' "' : Sr , '��.. lr•"'.. ..1- - r .., 1• ... .. r rit: 'tty -..` -.i ` -. .. .• • TABLE 5B tr. •.;, �OETERMI1 INGEN�RG AVINGSFR M' HOIATErR�RECOVERY'"'SYSTEMS' A hot water recovery system (HWRS) is a device which reclaims hot water energy from the distribution piping of thewater heating system. Efficiency of these systems"is dependent on household use patterns and the layout of the piping. Based ,on ':-an independent study - completed in 1983 by Battei"e. w.. yy Al Laboratories,-the,,,Commissi.on has determined,that: a HWRS can reclaim hot waterty ; t •fT•.,.N•e#yliN'•".}F'^•� t yi6 •}i?t6tW�'�ru,'e fL: ii t.- t - ).v -aft ..n M" a.A•. {„ .. Y-.: :r� . �.3s. ,j'y�r < energy.: 2i'7r..: LS•a:..%C:a ..-xR •.w> yfi ,{!.:.:•5'. ,�' _ - i.a.• ""'Y' „t.,.•rx ' .. .j •t.. ltr .moi The fixed values listed below may be used in line C2 of the WORKSHEET when a HWRS is specified. They were derived using the following formula: HWRS Savings = .15 x Water Heating Budget (Table 1) HWRS SAVINGS (KBtu/yr) Climate Zone Single Family M U L T I F A M I L Y * All "thers 1 3330 3330 2115 2 3120 3120 2550 3 3120 3120 2565 4 3090 3090 2535 5 3090 3090 2520 6 2910 2910 2385 7 2910 2910 2385 8 2910 2910 2385 9 2910 2910 2385 10 . 2910 2910 2385 11 3060 3060 2490 12 3090 3090 2520 13 3060 3060 2490 14 3135 3135 2580 C1`�-280.57 2805 2265 16 3435 3435 2835 Multifamily buildings with common walls but no common floors/ceilings. Installation Criteria: 1. HWRS must be plumbed such that a positive supply o; cold water from the water.' supply, main is provided to the appropriate connection on the device. 2. HWRS must be connected to each water heater serving individual dwelling units. 3. Credit for only one HWRS may be taken even though more than one may be installed or specified in the building plans. 4. Credit m'ay-not be taken for a HWRS in a multifamily central water heating ,system which serves multiple dwelling units: 5. Credit.;:may not be taken for a HWRS in a water heating system equipped with a recirculating hot water loop unless the recirculating pump has a demand pumping control as described in Table 3. +'- �:::rr:;. c:azservation .tlanual devised Juh 1990