Loading...
0309-115 (PAT)U) _N L1J (S C) ' W � Q � o Z C.0 0' o �V(D WW I— a Cl) Z co LO N ON _0 °) Z `rHcc0 0 J J m< O a LO M H 't Z_ co 5 ^0 Q J LICENSED CONTRACTOR DECLARATION I.hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and 1. Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 664-238 s423p Date Signature of,Contractor / �.�„_......,.�•--'may �.�•�,y'� `i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for. the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE" FUND Policy No. t�k�i�.1gP (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and-agrdi_t6i if I should become Ap subject to the workers' compensation.provisions of, -Section 3700 of the Labor Code, I shall forthwith comply with those prov_isions.r' Warning: Failure to,`secure Workers' Compensation -coverage is unlawful and shall subject an err ployerr to criminal penalties.a d civil fines up to $100,000, in addition to the cosi F-C-06pensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state•thatthe bove information is correct. I agree to comply with all City, -and State laws relating to the building construction, and hereby authorize jrep esd tatives of this City to enter upon the above-mentioned property for_inspecJ&on•purposes. Signature (OwnedAgen�/%y/-►%� Date PERMIT* - BUILDING PERMIT y - Iw&-11.5 TRACT DATE VALUATION ,3�LOT o9lutw0C tux) JOB SITE APN ADDRESS M-445 AVESMA JUM IZA. OWNER CONTRACTOR / DESIGNER / EN &NEER JAMEE SAVT MWARD QEC)RC'E Wt -OR 53445.A\rRN1D.A11 d 53a L"W_, 3.1C)'%VU R, LAQ1:,T1N'1:A `' CA ,922.51 t.,AQITRI'fA CA 92253 ` (t (POP71. -1180 CTRL# 2851 USE OF PERMIT PATIO 1$0 IY BUILT UP rar TTO COVF : PCk CITY STAN MRD PORC;HRATIO 130.00 O RS'.%IV"3�b°F D COST 011' CCNYERUC°IM 2,„394M PLAN CHECK FU 301-000�39m2118 X35.10 ("C44snuJC'ii om nF 101-000-419.000 $Sd.f10 STRONG IN16TION ISLE- fUr'.SID 101.000.241.000 ' S.50 SEP.10 2003 lj CITY OF LA C!:34�3'tA F1�1At4 CrFT. iUrB-TOTAL CONTIRD ON AND MAN C.M.0 AT "' ins PPs-AAM 17.> s 7 50100 '.I~QTAL MOM FENS XPE NOW $89.60 RECEIPT DATE BY`w DATE FINALE INSPECT // �/( INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bonb Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer.Connection Encapsulation Gas Piping Gas Test Appliances Final • Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: �,�,—� � .�� pass �,���s C /-` % 0y �LK� [[ 14 RAFTt R SPAN TABLE �� co O cc wc) : cs GRADING RULES"J.S 00 OS 207-70 (FEET & INCHES) 2x4 to"..o 24" _ �.. 8.,_, .. I� 6' -0.• -o.. I 7. _ 3" 1 I 2x6 16" O.C. 15'-0" 14'-0" 10'-9" 13'-0" SIZE 24" " 12'-6" 11'-6" 8'-9" 10'-6" 4x6 32" " 10-0" 8'-6" N/A N/A 2x8 16" O.C. 18'-0" 17'-0" 13'-6" 16'-0" 12'- 0" 24" 15'-6" i ' - =6" 11'-0" 13'-0" 6x10 32" " 13'-0" 1 11'-6" N/A N/A NOTES: 1. 32" RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID PATIO COVERS (NOT LATTICE) RAFTER SPAN IS LIMITED TO 10'-0" USING. THIS STANDARD. L ATTICE ROOF BUILT-UP ROOF HEADERS HEADERS DSUC. LAS FIR N. 1 DOUGLAS FIR NO. 1 i SPAN SIZE SPAN 1.,4x4 Wt 5'-0" 8'-0" 4x 4'-0" 4x6 6'-0" .4x8 8'-0" 4x8 1 1 '-0" 400 14'-0" 4x10 10'-0" 402 17'-0" 402 12'- 0" i I 6x8 14'-0" 6x8 12'-C' 6x10 17'-0" 6x10 14'-io' ALL CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF THE:. 2001 CALIFORNIA BUILDING CODE. SUPPLEMENTAL NOTES: ROOFING NOTES: A. BUIL-UP ROLLED ROOF: SLOPE TO DRAIN. B. ROCK ROOF: 3%12 MAXIMUM PITCH. RAFTER SIZE AND SPACING R( fF PITCH CONTINUOUS LEDGER (SAME SIZE AS RAFTERS) HEADER SIZE AFTEP SPAN: ---- _ O.H. 2000 P.S.I CONCRETE --+1 - ;FINISH GRADE L J a W a 0 c G _ POST SIZE.---- SIDE SETBACK (4'x4" MIN.) FINISH GRADE 1 L--- MIN. 12"x12' FOOTING I 1 L_J 12' BELOW GRADE L -J SPECIFY ROOFING AND SHEATHIN;, OR OPEN LATTICE (SEE ROOFlNG NOTE ON RfVARSE) In 1 ti -'T' AND 'L' STRAPS 6*x6*x1"%I/6" WITH h I (4) 16C NAILS OR BOLT Z POST SPACING O.H. OVERALL LENGTH r` T OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA VIA ONE 1/4' x 5" LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL. BUILDING DEPARTMENT APPROVAL BELOW CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE -91 02>1 Eff PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE —�, U -STRAP OR AN NON -CORROSIVE �gll• o Wo; (4)- 16d NAILS OR BOLT U -STRAP OR ANGLE — (4)- 16d NAILS OR BOLT PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE ANCHOR BOLT (EMBED — 7" MIN. INTO CONCRETE) TYPICAL PATIO COVER DATE OF APPLICATION �. OWNER'S NAME w/ S STREET ADDRESS 'r ys 151 CITY. ST ZIP 1-4 TELEPHONE H.O.A. APPROVAL