Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-5354 (AR)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T,iht. 4 4 a" Application Number: 05-00005354 Property Address: 53600 AVENIDA HERRERA APN: 774-124-006-19 -000000- Application description: ADDITION - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 3832 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT --------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions.of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: - - - - - - - - -- - - - Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by aXpplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 1/) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contr ors' State License Law does not apply to an owner of property who builds or improves thereon, and w o ontracts for the projects with a contractors) licensed pursuant to the Contractors' State License La (_ 1��Owner: , B.&P.C. for is reason IfDate: r CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097; Civ. C.). Lender's Name: Lender's Address: LQPERi,IIT VOICE'(760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760J 777-7153 Date: 12/08/05 Owner: GARCIA STEVEN A 53-600 AVENIDA HURRERA LA QUINTA, CA 92253 �stx -t info . . . . . C De Con c r. Ow DEC 0 9.1005 J. DI ION Crry OF LA QUINTN 0 01 / 2 0 0 5 FINANCE DEK LiC. - - - -'- ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NO POII Number E FOOTAGE certify that, in the performance of t ork for which this permit is issued, 1 shall not employ any person in any -manner so as to bOthwjUi e subject to the workers' compensat laws of California, y1 an agree that, if I should becoject t workers' compensati ovisions of Section // 3100 of the Labor(,°od _ se orovisi09. WARNIN& �AILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any2,ce omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application beco eand void if work is not commenc within 180 days from date of issuance of such per itsation of work for 180 days w' ject permit to cancellation. I certify that I have read this application and state thAiconstructi ation is rr e to co y with all city and county ordinances and state laws relating toon, ereby ize re sentativesof th'ouy tenter upon thea ove-mentioned prn ses. Dat //U S' ture (Applicant or Agent): 1 LQPERA11T Application Number . . . . 05-00005354 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 63.00 Plan Check Fee 40.95 Issue Date . . . . Valuation . . . . 3832 Expiration Date 6/06/06 Qty Unit Charge Per Extension BASE FEE 45.00 2.00 9.0000 THOU BLDG 2,001-25,000 18.00 ---------------------------------------------------------------------------- Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee 17.35 Plan Check Fee 4.34 Issue Date . . . . Valuation 0 Expiration Date 6/06/06 Qty Unit Charge Per Extension BASE FEE 15.00 67.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 2.35 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date Valuation 0 Expiration Date 6/06/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ----------------------------------------------------------=----------------- Special Notes and Comments 67 SQ. FT. ADDITION TO HOUSE December 8, 2005 1:19:48 PM JJOHNSON ----------- --------------------------------------------------- Fees . . . . . . . . . ENERGY REVIEW FEE 4.10 STRONG MOTION (SMI) - RES .50 Fee summary Charged Paid Credited Due -- - - - - - - - - - - - - - ------ - - - - ------ - - - - ------ - - - - ------ - - - - - - Permit Fee Total 104.35 .00 .00 104.35 Plan Check Total 51.29 .00 .00 51.29 Other Fee Total 4.60 .00 .00 4.60 .Grand Total 160.24 00 .00 160.24 0 Date 12/8/05 No. 27931 Owner Scott Garcia Address 53600 Avenida Hurrera City La Quinta Zip 92253 Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 4795.0 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units o. z: o BERMUDA DUNES r V% RANCHO MIRAGE INDIAN WELLS PALM DESERT y Ct� LA DUINTA INDIO y7ti 774-124-006 La'Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53600 Avenida Hurrera 67 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 67 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Scott Garcia Check No. Name on the check Telephone )blinding Exempt By Dr. Doris Wilson.� Superintendent i �1 Fee collected /exempted ar n MCGiI y �. Payment Recd g0.o0 QverMA-deir" Signature NOTICE: Pursuant to Government Code Section B6020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date-on-which- those ateon-whichthose amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting B`"# 5 City of La Quinta Building iii Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # D S35 Project Address: Owner's Name: S e oTT !� A. P. Number: 77 1/—Qo Address: 3-�Do )4vJ- Legal Description: Lar ITb %��� ct— (S' Contractor: �1� �vj/ cry City, ST, Zip: Telephone: Address: Project Description://—,//d/ pa/ 7-2� City, ST, Zip: / Telephone: State Lie. # : City Lie. #: Arch., Engr., Designer. Address: City, ST, Zip: Telephone: State Lie. #: Name of Contact Person: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. FL:67 #Stories: #Units: Telephone # of Contact Person,: - Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING . PERMIT FEES Plan Sets a� Plan Check submitted 1 It,, Amount Structural Calcs. Reviewed, ready/r corrections Plan Check Deposit Truss Calcs. Called Contact e I o Plan Check Balance Energy Calcs, Plans picked up Construction Flood plain plan Plans resubmitted j��p Mechanical Grading plan 2d Review, ready for correctio srssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3W Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 0 TITLE 24 REPORT oAot MtRA Title 24 Report for: Garcia Residence 53-600 Avenida Herrera a , La Quinta,.CA Project Designer: " 1 Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 Job Number: NO V 0 2 2005 Date: - BY 10/31/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: User Number: 2655 5 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 I EnergyPro 4.0 by EnergySoft Job Number: User Number: 2655 Certificate Of Compliance: Residential ❑ Addition (Part 1 of 3) CF -1 R (',arria RPcidencp Project Title 53-6nn Avenida HPrrPra L�Qtainta ❑ Multi Family Q Existing + Add/Alt 1 n/31 /2nn5 Date Project Address Building Front Orientation: (West) 270 deg Raised Floor Area: Building Permit # Insll-form Inc Natural Gas (760) 779-0657 1,904 ft2 Documentation Author Telephone Plan Check/Date FnPravPrr) Complilgrice Method 201 ft 2 Avg. U: 0.84 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance Number of Stories: (kBtu/sf-yr) Design Design Margin # of Thermostat Space Heating 6.74 4.97 1.78 Units Zone Type Type yap_ rnndalnned Setback— Space Cooling 102.84 103.58 -0.74 Fans 15.82 15.34 0.48 Domestic Hot Water 11.83 13.32 -1.49 Pumps 0.00 0.00 0.00 Totals 137.24 137.21 0.04 than Standard: Building Type: 5fl Single Family ❑ Addition Total Conditioned Floor Area: 1,904 ft2 ❑ Multi Family Q Existing + Add/Alt Existing Floor Area: 1,352 ftz Building Front Orientation: (West) 270 deg Raised Floor Area: 0 ft Fuel Type: Natural Gas Slab on Grade Area: 1,904 ft2 Fenestration: Average Ceiling Height: 8.7 ft Area: 201 ft 2 Avg. U: 0.84 Number of Dwelling Units: 1.00 Ratio: 10.6% Avg. SHGC: 0.69 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name I Ming lone Floor Area Volume 1 9na 1�6 58p Units Zone Type Type yap_ rnndalnned Setback— Hgt. Area —2 —n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 12n n 074 R_19 R -n n 97n Ap Wall Wood 99 0074 R-14 -n n 115 9Q Wall Wood 198 0074 R_19 R_0 n _n -9 Wall Wnnd 22 n n74 R_19 R-0 0 995 _sp Rnof Wnod 557 n o:i2 R_3n R-0 0 180 Wall Wood 780 n 110 R_11 R-00 97n An nnnr NnnP 9n 1 450 Non R-0 0 970 -qQ Wall Wnnd R7n n 11n R_11 R-10 77n -qn Wall Wood 457 0 11 n R_11 R-0 0 n gn Wall Wood ?nn n_110 R_11 R-00 0 Q Wall Wnnd Fiss n110 R_11 R -nn gn A Wall Wnnd 470 _0 11 n R_1 1 R-1 n gn P Wall Wnnd 285 0 110 R_11 R-0 0 18n _90 Roof Wnnd 1,352 0 051 R_19 R-0 0 770 Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:3 of 10 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Garcia Residence 10/31/2005 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Window Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments J_ Windnw Front_(W(West) 16n 079 NERC: 06 NERC 970 _9L New Do ihl Mtl In .nated Addition 2 Window Front Northwest 8.0 0.720 NFRC 0_63 NFRC 315 90 New Double Mtl Uncoated Addition 3 Window Left (North) 2.0 0.720 NFRC 0_63 NFRC 0 90 New Double Mtl Uncoated Addition 4 Window Right (Southwest 8.0 0.720 NFRC 0_63 NFRC 225 90 New Double Mtl Uncoated Addition 5 Window Left (North) 24.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone 6 Window Lefto h) 24.0 0.870 NFRC 0.70 NFRC 0 90 Existing_ Double Mtl Uncoated Default Living Zone Z 0.1 2.0 2.0 80.0 0.870 JNFRQ 0 70 NFRC 90 90 Removed Double Mtl Uncoated Default Living Zone 8 Window Rear (East) 24.0 0.870 NFRC 0.70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 5 Window Right (South) 40.0 0.870 NFRC-Q.70 NFRC 180 __Q Existing Double Mtl Uncoated Default Living Zone 10 Window Right (,South) 3.0 0=870 NERC 0_70 NFRC 180 90 Existing Double Mtl Uncoated Default Living Zone 11 Window Right (South) 12.0 0.870 NFRC 0.70 NFRC 180 90 Existing Double Mill Uncoated Default Living Zone 12 Window Right (South) 40.0 0.870 NFRC 0_70 NFRC 180 90 Existing Double Mtl Uncoated Default Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside Condition Location/ Window (sq (in.) Cap. Cond. R -Val. Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 1.0 3.0 2.0 0.1 2.0 2.0 Ti Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 THERMALWASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 New Addition Slab Perimeter 122 None No Insulation 26-A1 Existing Living Zone Run Initiation Time: 10/31/05 14:32:16 Run Code: 1130797936 EnergyPro 4.0 by Energysoft User Number: 2655 Job Number: Page:4 of 10 Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R Garcia Residence 10/31/2005 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living one Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Living Zone Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ezt. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Twe In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business 8 Professions Code) Name Title/Firm: Address: Telephone: ' Lic. M (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: Joan D. Ha Title/Firm: I nsu-form. Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: (760) 779-0657 (signatu ) (date) (signature/stamp) (date) EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Paae:5 of 10 1 Certificate Of Compliance: Residential (Addendum) CF -1 R Garcia Residence 10/31/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Existing Wall "Front Wall" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Front Wall Removed" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Left Wall" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Left Wall Removed" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Rear Wall" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Rear Wall Removed" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Right Wall" has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Roof "Roof' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- arr�...�.. 01— 111-- ICFUIL=U U11 L51=I Plan I Field installation certificate. EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Pape:6 of 10 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑X ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: Q ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not Q ❑ ❑ apply to exterior mass walls). Q ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. 1K ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox 0 ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. b. outside air intake with damper and control, flue damper and control EK ❑ ❑ 0 2. No continuous burning gas pilot lights allowed. ER ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. 0 ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor 0 ❑ ❑ Q permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑X ❑ ❑ ❑ CF -6R Form: EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑X ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain infiltration EK ❑ ❑ Coefficient (SHGC), and certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑X ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ER ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE„SMACNA or ACOA. ❑X ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑X ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation Q ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑X ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑X ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and 0 ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ER ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed Q ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified_ by the Solar Rating and Certification Corporation. ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. WA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, X❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than X❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. FXI 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating FXI dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. C ❑■ ® ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ® ❑ ❑ b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ® ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (): Cool Roof material meets specified criteria X❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table © ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, X❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined X❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.X❑ ❑ ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are X❑ ❑ ❑ controlled by an occupant sensor that complies with Section i 19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the 0 ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Garcia Residence 10/31/2005 SYSTEM NAME FLOOR AREA Living Zone 1,904 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 5,405 34,337 3,411 1,443 36,141 0 6,108 4,637 0 0 0 0 0 0 0 0 0 6,108 4,637 46,5531 3,4111 45 414 HVAC EQUIPMENT SELECTION BRYANT 597CNX036000 40,295 28,337 120,000 Total Adjusted System Output 40 295 28,337 120,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12m EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.0°F 69.0°F 94.50F ";" Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 93.5 °F 4420 cfm ROOMS 70.0 OF 69.0 °F a `n Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.9/77.6°F 79.3/69.2°F 79.3/69.2°F 70.7/66.3°F Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 72.0 / 66.7 OF 4420 cfm 63.2% R.H. ROOMS 79.3/69.2 °F 78.0 / 68.8 OF h Return Air Ducts y EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:9 of 10 1 ROOM LOAD SUMMARY PROJECT NAME Garcia Residence DATE 10/31/2005 SYSTEM NAME Living Zone FLOOR AREA 1,904 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 1 226 7,791 1,325 1 226 7,791 1,325 230 5,752 Living Zone Existing Living 1 4,179 26,546 2,086 4,179 26,546 2,086 1,213 30,389 PAGE TOTAL 1 5,405 34,337 3,411 1,443 36,141 TOTAL 1 5,405 34,337 3,411 1,443 36,141 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 10