Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
002015 (SFD)
Building Address Sii1; Owner phy tww Mailing ' Address City Zip A=rtia Contractor S.. T a 0 it�t 4 04� Quin& Tel. P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 No. 0020.5 BUILDING: TYPE CONST. V - OCC: GRP.- � A.P. Number 774-123-01-9 Legal Description 7-ift Project Description 1 1 l "a 20739 #25 LyaqniM° ZONE: BY: ' "City Minimum Setback Distances: Tela Front Setback from Center Line MOT"Zip - 4.IN9 525-2*R06 CONSTRUCTION LENDING AGENCY State Lic. City UAIG 13" & Classif:W r 121sss Lic. # Sq. Ft. 1 480 No. No. Dw. �- • Arch., Engr.; Size - Stories Units FINAL DATE INSPECTOR Designer New •® Add ❑ Alter ❑ Repair ❑ ' Demolition ❑ Address Tel. I certify that I have read this application and state that. the above information is correct. Issued by: Date Permit agree to comply with all oity'and -county ordinances and -state laws relating to building. City Zip State mentioned property for inspectionpurposes._ _ .--� "—J'� �'/Y ^ Signature of applicant i y � F �• r / J JIX., f s Lic. # ~ LICENSED CONTRACTOR'S DECLARATION /j Validation: I hereby affirm a that I m licensed under provisions,ofthapter 9 (commencing with Section 7000) of Division 3 of the Business and Professio^nSs_'C_ode„and niy,license is in full force and'.l effect, :r.i Jf �1 _lrr 1T � - r •f fir.... -) "., A4005 1 28 688.3G U _. _SIGNATURE' - %.% I DATE OWNER BUILDER DECLARATION f Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following C glh $ 0.226. reason: i on: (Sec. 7031:5, Business and Professions Code: Any county which requires a permit to construct, alter, improve, demolish, or repair anystiiiclure, prior to its issuance also l' requires the applicant for such permit to file a signed statement that: he is licensed pursuant to PERMIT s AMOUNT • the provisions of the Contractor's License Law, Chapter 9 (commencing with.Section 7000) of ,. Division 3 of the Business 'and Professions Code, or. that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5- by 'any applicant for a permit . Plan Chk. Dep. ',1 rt ' subjects the applicant to a "civil penalty of not more than five hundred dollars ($500):' Plan Chk. Bal. ".71 O_I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec.- 7044, Buisness and Professions Const. O;Jh) Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, Mech. provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold. within one year of completion, the, owner -builder will have the burden • EI@CtrlCdl of proving that he did not build or improve for the purpose of sale.) - ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- -Plumbing struct the project. (Sec. 7044, Business and Professions Code: The. -Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. A QA such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) - - Grading _ ".00 ❑ I am exempt under Sec. B. & P.C. for this reason Driveway Enc. 20,00 Date owner- Infrastructure WORKERS' COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of iI Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company a. Copy is.filed with the city. ❑ Certified copy is hereby furnished. TOTAL CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed i1 the permit is for onehundreddollars ($100) valuation or less.) - i I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. REMARKS Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY: ' subject to the Workers' Compensation provisions of the'Labor 'Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear. Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This is a building permit when properly filled out, signed and validated, and is subject to - expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that. the above information is correct. Issued by: Date Permit agree to comply with all oity'and -county ordinances and -state laws relating to building. construction, and hereby authorize representatives of,, tKis1city to.-entei the above- mentioned property for inspectionpurposes._ _ .--� "—J'� �'/Y ^ Signature of applicant i y � F �• r / J JIX., f s Validated by: Mailing Address r~ -' tl Validation: City, State, Zip' --- - -- �.�' A4005 1 28 688.3G U _. HARD COPY CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SQ. FT. ® $ UNITS LAB GRADE Z � , Q *rtOUGH PLUMB. Z �� BONDING YARD SPKLR SYSTEM 2ND FL. SQ. FT. @ FORMS 'SEWER OR SAC� 6 OUGH WIRING Z� MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® GAS (ROUGH) METER LOOP GAR. SO. FT. ® POWER OUTLET ROOF DRAINS GAS (FINAL) A GYEMP. POLE _/1 DRAINAGE PIPING CAR P. I SO. FT. ® GROUT WATER HEATER WALL SQ. FT. FINAL INSP. DRINKING FOUNTAIN SO. FT. ® WATER SYSTEM URINAL ESTIMATED CONSTRUCTION VALUATION $ =$ WATER PIPING NOTE: Not to be used as property tax valuation 4fRAMING 2 FLOOR DRAIN MECHANICAL FEES ` WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 c SEWAGE DISPOSAL 1' _NSULATION/SOUND SQ.FT.GAR ® 3/ac HOUSE SEWER FINISH GRADING GAS PIPING PERMIT FEE FINAL INSPECTION PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK P ROUND PLUMBING 2i�/ UNDERGROUND A.C. UNIT COLL. AREA LAB GRADE Z � , Q *rtOUGH PLUMB. Z �� BONDING HEATING (ROUGH) STORAGE TANK FORMS 'SEWER OR SAC� 6 OUGH WIRING Z� DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) A GYEMP. POLE _/1 GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. 4fRAMING 2 FINAL INSP. ROOFING ` DEC 17 1r�l REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING 3 �' MESH 1' _NSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS, GARDEN WALL FINAL T414f 4 4 Quigro 5� P.O. BOX 1504 APPLICATION ONLY Building 78-105 CALLE ESTADO Address LA QUINTA, CALIFORNIA 92253 Owner 69 L11 i BUILDING: TYPE CONST. OCC. GRP. Mailing / Address / QQ�-�/� I A.P. Number % 74,/ / - /Z 5— F City 11 TZip// Tel. '� � � tUL 40,4 7-1 �Zlv�� Legal Description L 6 7-14-y-���. Z30 - UA/f 7 Z Z Contractor- - Project Description Address Z0 L. e4 /?Q 1-4City e I d % LIZ % ZI` / Tel.. State Lic. & Classif./ 32 �—�—�- City Lic. # Sq. Ft. No. / No. Dw. / Size / Stories Units Arch., Engr., Designer New 2�' Add ❑ Alter ❑ Repair ❑ -Demolition ❑ Address Tel. City Zip State LICENSED CONTRACTOR'S DiCLARiTION I her�yy firm that I a�tcensed-under progisiioons of Chaptey9 (commencing with Section 7000)lof DiDiv�ision 3 of the Busi ess-and Professions�Code! nd my icense is iyn full orceeand effece/,>-/ ,-% 77 �� 7 /J — � t SIGNA�TTU�RE�""— DATE .OWNER.—BUILDER DECLARATION fl hereby affirm that I'am'ezempt-from the Contractor's License Law for the following reason: (Sec. 7031.5,Buslness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty or not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property -who builds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. B. ti P.C. for this reason S.M.I. Grading Driveway Enc. Date owner Infrastructure WORKERS' COMPENSATION DECLARATION Ihereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. TOTAL ape a CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE REMARKS (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.)," Side Street Setback from Center Line Side Setback from Property Line Lender's 'Name FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above Information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for Inspection purposes. Signature of applicant Date .Mailing Address Validation: A 3 7 7 7 1 9 2 5 0, 0 0 CK City, State, Zip BUILDING DIVISION CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ UNITS SLAB GRADE ROUGH PLUMB. BONDING YARD SPKLR SYSTEM 2ND FL. SO. FT. FORMS SEWER OR SEPTIC TANK ROUGH WIRING MOBILEHOME SVC. BAR SINK POR. SO. FT. ® GAS (ROUGH) METER LOOP GAR. SO. FT. ® POWER OUTLET ROOF DRAINS GAS (FINAL) TEMP. POLE DRAINAGE PIPING CAR P. SO. FT. ® GROUT WATER HEATER WALL SO. FT. FINAL INSP. DRINKING FOUNTAIN BOND BEAM WATER SYSTEM URINAL SO. FT. ® =$ LUMBER GR. ESTIMATED CONSTRUCTION VALUATION $ FINAL INSP. WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED FIRE ZONE ROOFING LAUNDRYTRAY AIR HANDLING UNIT CFM FIREPLACE KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB MESH SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® 3/ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL 2y �y0 H BERMUDA DUNES r RANCHO MIRAGE INDIAN WELLS �+ d PALM DESERT a ,P LA OOINTA '`p INDIO Desert Sanas Unified School District 82.879 HIGHWAY 111 A INDIO. CALIFORNIA 92201.5678 • )619) 347.8631 January 7, 1986 a City of La Quinta Department of Community Development 78-105 Calle Estado La Quinta, CA 92253 Re: Lot, Blk 230, Unit 22 Gentlemen: ' The developer of the above referenced lot has mitigated its impacts on our overcrowded schools by payment of the amount of $628 per unit to be applied to the cost of district educational facilities made necessary by such new development. Sincerely, � rL i. n --L John D. Brooks Assistant Superintendent Business Services JDB/crm Q Z 0 I— U W l W U Z O U W y ..... -r _ .ter. i • — .. �, - • <• .__ .� •��. . y,. . { r — /1Zc,c/2 Receipt No. � 6 7 2 7 7 Issued By QV District: Riverside ❑ Indio -0 Hemet ❑ Date. 9 3a -S - DISTRIBUTION: WHITE - Office File YELLOW - Applicant PINK - Building Dept. GOLDENROD - Pending File DOH SAN 122 (Rev 10/84) 71-L G - -2 COUNTY OF RIVERSIDE, DEPARTMENT OF HEALTH ' • t 1 PERMIT APPLICATION FOR A SUBSURFACE DISPOSAL SYSTEM ' Applicant: Submit this form with three copies of a scaled plot plan drawn to county specifications required on the attached check list. A non refundable filing fee of $15 is required when the application is submitted. Check must be made payable to County of Riverside. Name Mailing Address H6 -S, m 6 NOryme".t" C.ov� (�,Q,�C30y, Sl, 3S City 1L) eyto►-� State Zip Code S Phone 71 s -?)804 'Property Address LCity.or Community-- 'Legal Description of Property (Lot, Parcel Map, Tract) S C3 I K a 3 o ULA; T 2 'Assessors Parcel No. Water, Serving Prop ert From Lot size s p n / Signature of Applicant Date ! / '• 'The above information must be verified from Building Application Staff Use — Do Not Write Below This Line Initial Date WQCB Clearance required Yes ❑ No ED Soils feasibility report required Yes ❑t.` No © , Yes No Detailed boring report required Q 1) Q Detailed contour plot required Yes El No s Comments: Soils or boring report by Date Approved by ^\\�-- ,DVte. / / (� �yG G r �Z Soils Map Page Soil Type Tract File No.z Oth r�fx Number of Bedrooms i/ 3 Septic Tank Size (gallons) V / 0� W Rate Required �� /r i/a,�ldy Type of System New Addition Replacement `� ❑--` Leach line sq. ft. of bottom area trench Leach bed (sq. ft. of bottom area bed) � r Seepage Pit Diameter Number of Pits Seepage Pit Depth B. 1. Total Depth of Pit Location of System Add itionalRequirements yy�ty i Zryz a... 0664ff .LcQ4Y A permit is approved/denied for the design of a subsurface disposal system as indicated on the accompanied plot plan using the requirements set forth in Section B above. A building permit is necessary for the installation, of the above designed system. W Signature of Health Official— Date I/ 7—/TL1 ITL1 /1Zc,c/2 Receipt No. � 6 7 2 7 7 Issued By QV District: Riverside ❑ Indio -0 Hemet ❑ Date. 9 3a -S - DISTRIBUTION: WHITE - Office File YELLOW - Applicant PINK - Building Dept. GOLDENROD - Pending File DOH SAN 122 (Rev 10/84) 71-L G - -2 s T I TL_E 't 4 P4.e:LAJ F=<EE3 I I3EM-I IAL_ FF— P4 EZ- F (3 '%r' S L-P JEC M I T" T L FOR BUILDING 1, LA QUINTA SUBDIVISIONS, LA QUINTA COMPUTER RUN BY IE M E FR C'V 1 714-968-3062 TITLE �4 GC3MF="L. I ANGE AF=P F'FCaif-1iGH ZONE 15 PROPERTY: BUILDING 1, LA QUINTA SUBDIVISIONS, LA QUINTA APPROACH: AB163 SLAB FLOOR, 1 STORY, 98% ATTIC COMPLIANCE: ALLOWED POINTS 74 PROPOSED POINTS -3 SPECIAL REQUIREMENTS: 1. INSULATION: CEILING - R38 SLAB P - NONE WALL - R11 2. GLAZING: ALL SINGLE GLAZING 3. SHADING: WHITE ROLLER SHADES ON NORTH & EAST GLAZING 4. THERMAL MASS:(SEE ATTACHED BREAKDOWN) 139SF OF 3.5IN UNCARPETED SLAB 5. HEATING: HEAT PUMP W/ 8.0 EER & NITE-SETBACK 6. WATER HEATING: GAS OR HEAT PUMP 7. OTHER: - EXTERIOR WALL ELECTRIC OUTLET GASKETS "THEFcM L— M 1B E3 _ TAF Z"EOFF SHEE.T PROPERTYa BLDG 1, LA QUINTA SUBDIVISIONS, LA QUINTA LOC TYPE W L SF 1. SLAB KIT 3.51N 4 9.55 38 2 i 3 b BA 1 " 5 5.5 28 3.. 5 15 BA 2 5 7.'5 37 3 5 - 15 TOTAL 139 T I TLE 24 CPrLC:::UL._AT I C3 P4 , '.�- HEET PROPERTY: BLDG 1, LA QUINTA SUBDIVISIONS, LA QUINTA SUBJECT: MASS CALCULATIONS 1. CONCRETE SLAB: 3.5IN UNCARPETED'SLAB - 139SF WT = 3.5 * 150 / 12 44 R = 3.5 * .08 = .28 HC (TBL 3-14A) 8 MCF (T BL -14C) = 7.8 MASS CAPACITY: 1. 131 * 7.8= 1084 MC = 1084 / 1344 = .81 THERMAL MASS POINTS: FROM TABLE 3-14E TMP = +b O%A:02 R5 4/03/84 VH/dr Climate Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Point System Compliance Goal for Assembly Bill 163 AB 163 Compliance Goal Package 0 Slab Floor For .1 -Story Fo r 2- or 3 -story Buildings Buildings 0* -1 -7 -13 -6 -10 F -9 -13 -3 -9. -5 -9 -2 -8 -7 -13 -2 -10 -8 -14, -7 -11 0* -1 -5 -11 -9 -13 -4 _8 -6 -8 Attachment A AB 163 Compliance Goal Package_E Raised Floor)__ For 1 -Story For 2- or 3 -story Buildings_ Buildings 0* 0* -16 -16 -3 -3 -10 -10 -10 -10 -11 -11 9 -9 -12 -12' 9 -11 -15 -15 -12 -12 0 -2 -9 -11 -11 -17 -6 -8 -4 -4 *The AB 163 compliance goals for climate Zones 1 and 12 calculated to positive scores, but the standards require no greater than a zero score (a zero point system score equals the energy budget for the particular climate zone). G C3 M F L_ I d!nb Fq C.:. E_ E:. IF -4 E i:.-.: fF L_ I !E; lr 2r' C3 hi E-_- PROPERTY ADDRESS: BUILDING 1 - LA QUINTA SUBDIVISIONS. LA QUINTA P'ROP'OSED SYSTEM BUILDING SHELL MEASURE **TOTAL FLOOR AREA 1344 SF 1. SLAB PERIMETER INSUL DEPTH 0 IN R-- 0 3. CEILING INSULATION ( 90% ATTIC. ADD 4 POINTS) R- 30 4. WALL INSULATION R--- 11' GLAZING % AREA SINGLE DOUBLE 5. NORTH FACING 4.46 % 60 SF= i i SF 6. EAST FACING 1.19 % 16 SF i i SF 7. SOUTH FACING 6.1 % 82 SF 0 SF Go -WEST FACING 0 % 0 SF 0 SF � 9. SKYLIGHT 0 % 0 SF 0 SF 10.SHADING COEFFICIENT A. EAST SHADING .25 SC B. SOUTH SHADING 1 SC C. WEST SHADING .0 SC D. NORTH SHADING .25 SC E. SKYLIGHT 0 SC 1 1 !HORIZONTAL SOUTH OVERHANG, LENGTH 2 FT 12. MOVABLE INSULATION. "/. OF FLOOR AREA % & INFILTRATION MEDIUM 14.THERMAL MASS, EXTERIOR MASS Q SF HC- 0 R- 0 INTERIOR MASS 139 SF HC-- G R-:- ow28 HVAC SYSTEMS 16.HEAT PUMP 0 EER DOMESTIC WATER HEATING 21.GAS WATER HEATER POINT SYSTEM COMPLIANCE TOTAL enernyl computer run zone Q M FORM POINTS -4 4 -- 6 -6 0 0 0 6 1 x ow FORM PROPERTY ADDRESS: BLDGS 1. °< 2 - ,LA QUI NTA SUBDIVISIONS. LA QUI NTA SITE INFORMATION HEATING DEGREE DAIS` 1 . 12.32 P / DAY OUTSIDE DESIGN TEMPERATURE "':1' F. P'ROP'OSED BUILDING ENVELOPE INFORMATION GROSS FLOOR AREA 3. 1344 SF" GROSS WALL AREA 4. N/A DESIGNED GLAZING AREA 5. 158 SF BASIC GLAZING AREA .6.. ?15 SF, DESCRIPTION OF ASSEMBLY SINGLE GLAZING 7. 1.1 £iTU/HR/Sf= DOUBLE GLAZING 8. .65 BTU/HR/SF SKYLITE GLAZING 9. C> BTU/HR/SF WALL ASSEMBLY #1 10. .08 Fs-C,U/HR/SF WALL ASSEMBLY #2 11. .075 BTU/HR/SF ROOF ASSEMBLY #1 14. .025 BTU/HR/SF ROOF ASSEMBLY.#2 15. BTU/HR/SF CONC SLAB EDGE #1 16. 21 BTU/HR/LF CONC SLAB EDGE #2 17. 0 BTU/HR/LF PROPOSED SPACE HEATING SYSTEM BUILDING HOURLY H1. -AT LOSS 18. 2984' BTU/HR MAX ALLOWED CAPACITY 19. =8794 BTU/HR KITE -SET -BACK ALLOWANCE(1.3*10BTU/SF) 19A. 17471 BTU/HR MAX WITH NITS -SET --BACK; 19B. 5666 BTU/HR energyl/heatlassl Fm Ff C3 0 EE c_— -T- ��E---- enk -r L. C3 SS E3 �eA L. C.-, tJ L_ '17 1 C-3 I'q FORM2 PROPERTY ADDRESS: BLDGS. 1 & 2 - LA QUINTA SUBDIVISIONS, LA QUINTA DESIGN TEMPERATURE DIFFERENCE � FOR CONDITIONS OTHER THAN BELOW 70 - 31 1. 39 DEG F ' UNINSULATED FLOOR OVER UNHEATED SPACE LINE1./2 2. 19.5 DEG F INSULATED FLOOR OVER UNHEATED SPACE LINE2.-5 3. 14.5 DEG F CO.NDPCTIVE HEAT LOSS ASSEMBLY SF -LF U FAC FRM FAC TEMP DIF BTU/HR SINGLE GLAZING ` 158 X 1.1 X 1 X 39 6778 DOUBLE GLAZING 0 X .65 X 1 X 39 = 0 SKYLITE GLAZING 0 ' X 0 X 1 X 39 = 0 WALL ASSEMBLY 1 914 X .08 X 1.18 X 39 = 3364 wALLASBEMBLY 2 ' 144 X .075 X 1^13 X 39 = 475 ROOF ASSEMBLY 1 1344 X 1025 X 1.06 x 39 = 1389 ROOF ASSEMBLY 2 0 X 0 X 0 X 39 = 0 CONC SLAB EDGE 1 152' X 21 X 0 X 0 = 3192 COW SLAB EDGE 2 0 X0 X 0 X 0 = 0 SUBTOTAL (TOTAL CONDUCTIVE HEAT LOSS). ' 4. = 15198 INFILTRATION LOSS 1344 SF X 8 FT X .018' X 39 5. = 10752 SUBTOTAL (ADD LINES 4. . & 5.) 6. . = 25950 DUCT HEAT LOSS (15% OF LINE 6.) 25950 X .15 7. = 3892 SUBTOTAL (ADD LINES 6. & 7.) 8. =.29842 NIGHT SET -BACK ALLOWANCE 1344 X 10 9. = 13440 TOTAL HEAT LOSS ' (ADD LINES 8..& 9.) 10. = 43282 MAXIMUM AL -LOWED OUTPUT 43282 X 1.3 11. = 56266 ' energv1/heatloss2 ` ` ' ' ` HIE n _ -F'" F=i P4 S F= C F;: C) F= F= r-- I � I E= tJ :_F_' by FORM •_+ WALL ASSEMBLY 1 COMPONENTS R VALUE 1. 7/81N STUCCO 0.16 2. 15# FELT 0.06 3. R-'1 1 HATT'S 11. 00 4. 1/2IN DRYWALL 0.45 5. INSIDE AIR FILM 0.68 6. OUTSIDE AIR FILM 0.17 TOTAL RESISTANCE 12.54 U FACTOR 0.060 WALL ASSEMBLY 2 COMPONENTS R VALUE• ' 1. 1/2IN DRYWALL_ 0.45 2. R-11 BATTS 11.00 _. 5/8.IN DRYWALL 0.6' 4. INSIDE AIR FILM 0.68 5. OUTSIDE AIR F=ILM 0.68 TOTAL-RESISTANCE 13.43 U FACTOR 0.075 ROOF ASSEMBLY 1 COMPONENTS R VALUE 1 . ASPHALT SHINGLES 0. 44 2. 1/21N SHEATHING 0.62 3. R-38 HATTS 38.(.-)o 4. 1/2IN DRYWALL 0.45 5. INSIDE AIR FILM 0.62 6. OUTSIDE AIR FILM 0.17 TOTAL_ RESISTANCE 40.30 U FACTOFt 0.025 M n Ink _r C3 F=< Ne F-- F= dnk -IF U F=,C FEE E3 E: vi 1-4 C) Li E; EZ PROPERTY ADDRESS: LAQUINTA SUBDIVISIONS, LA QUINTA BUILDING ENVELOPE 1. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACE MUST BE FULLY WEATHERSTRIPPED. 2. THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED OR SEALED: A. EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES. B. BETWEEN EXTERIOR WALL SOLE PLATES AND FLOORS AND BETWEEN EXTERIOR WALL PANELS. C. PENETRATIONS IN WALLS, CEILINGS, AND FLOORS FOR PLUMBING AND ELECTRICAL DISTRIBUTION SYSTEMS. . D. OPENINGS IN ATTIC FLOORS. E. ALL OTHER OPENINGS.IN THE BUILDING ENVELOPE. 3. MANUFACTURED DOORS AND WINDOWS MUST BE LABELED AND CERTIFIED PER ANSI, AAMA, NWMA, FHOA, OR ASTM STANDARDS. 4.. EXHAUST FANS, SHALL HAVE BACKDRAFT OR AUTOMATIC DAMPERS. 5. IF A MASONRY OR FACTORY -BUILT FIREPLACE IS INSTALLED, IT SHALL HAVE THE FOLLOWING: A. CLOSEABLE METAL OR GLASS DOORS COVERING THE ENTIRE OPENING OF THE FIREBOX, EXCEPT THAT A DOOR IS NOT REQUIRED IF IT WOULD INTERFERE WITH ANY DEVICE, PERMANENTLY INSTALLED IN THE FIREPLACE, THAT IS DESIGNED TO INCREASE THE CIRCULATION OF HEAT.' B. A FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL. HEATING AND COOLING 1. THE HVAC SYSTEM WIiLREQUIRE THAT'AEAT LOSS CALCULATIONS BE PREPARED TO SIZE THE SYSTEM. THESE CALCULATIONS SHOULD BE PREPAREDON ONE OF THE STATE APPROVED FORMS, 2. THIS UNIT MUST BE IpPED WITH A PROGRAMMABLE NIGHT ` SET -BACK THERMOSTAT. 3. FOR THIS UNIT.THE MAKE, MODEL NUMBER AND BTU OUTPUT MUST BE SHOWN ON THE PLANS. SELECT FROM THE STATE APPROVED LIST AVAILABLE IN THE BUILDING DEPARTMENT. PG 2LA QUlNTA SUBDIVISIONS, LA QUINTA 4�INSULATE ALL DUCTS ACCORDING TO UNIFORM MECHANICAL CODE, CHAPTER 10 OF THE 1979 EDITION. ' WATER HEATING 1. INSULATE TANK WITH R-12 EXTERNAL BLANKET. 2. INSULATE INLET AND OUTLET PIPES WITH R-3FIRST 5 FEET. 3. SHOW MAKE, MODEL, AND SIZE OF WATER HEATER ON PLANS. LIGHTING 1. GENERAL LIGHTING IN KITCHENS AND BATHS SHALL HAVE AN EFFICIENCY OF NOT LESS THAN 25 LUMENS PER WATT, EXCEPT THAT LUMINAIRES USED AS THE ONLY LIGHTING IN BATHS ARE EXEMPT FROM THIS REQUIREMENT. CERTIFICATION I CERTIFY THAT ALL OF THE ABOVE MANDATORY FEATURES HAVE BEEN INCORPORATED INTO THE PROJECT PLANS FOR THIS PROJECT, AND THAT THESE'pLANS COMPLY WITH THE TITLE 24 ENERGY REQUIREMENTS. PLAN PREPARER DATE energy1/mannew � COMPLEX SPACE INPUT PRINTOUT H&.S MANAGEMENT,RESIDENCE DATE PREPARED: 12/ 9/85 20615842.Q WALL TYPE WEIGHT (lb/sgft) EXTERNAL COLOR U -VALUE (Btu/hr/F/sgft) 1 L. M 0.08 2 - -------------------------------------------------------------------------------- ROOF TYPE SHADED WEIGHT EXTERNAL U -VALUE AREA ALL DAY? (lb/sgft) COLOR (Btu/hr/F/sgr-t) (sgft) 1 N L. L 0.03 19344 i 2 3' ------------------------------------------------------------------------------ GLASS TYPE U -VALUE WEIGHT SHADE INTERNAL (Btu%hr/F/sgft) (lb/sgft) FACTOR SHADES? 1 1.13 L 1.00 N, 2 1.13 L 1.00 N 3 1.13 L 1.00 N ---•-----------------------------------------------•--------------------------- SHADE TYPE WINDOW REVEAL ------OVERHANG----- -------FINS------- HEIGHT(ft) DEPTH(in) HT (in) EXTEN(in) SEP (in) EXTEN(in-) 1 4.0 0.0 1.0 36.0 0.0 0.0 2 3.0 0.0 1.0 36.0 0.0 0.0 3 ------------------------------------------------------------------------------ 6.0 0.0 1.0 36.0 0.0 0.0 PARTITIONS9CEILINGS9FLOORS AREA U -VALVE --------DELTA T-------- ADJ TO UNCONDITIONED SPACE (sgft) (Btu/hr/F/soft) COOLING HEATING Walls 144 0.08 40 F 20 F Ceilings 0 0.03 0 % 0 Floors -------------------------------------------------------------------=--------- 0 0.08 0 % 0 SLAB FLOOR 1. Area = 1344 sqft a 2. Perimeter = 152 ft 3. Depth = i ft ----------------------------------------------------------------------------- INFILTRATION AND INTERNAL LOAD DATA: 1. TOTAL FLOOR AREA = 11'344 sq ft 2. COOLING SEASON INFILTRATION AIR = 0.05 Cfm/sgft 67 Cfm Total 3. HEATING SEASON INFILTRATION AIR = 0.05 Cfm/sqft •67 Cfm Total 4. PEOPLE 269 sqft/person FOR TOTAL 5 PEOPLE OCCUPANCY SCHEDULE 3 ACTIVITY LEVEL 2: OFFICE WORK/RETAIL STORE SENSIBLE 245 Btu/hr/per LATENT 205 Btu/hr/per 5. LIGHTING 1.00 Watts/sgft FOR'TOTAL 11344 Watts LIGHTING SCHEDULE : 17 LIGHTS ARE INCANDESCENT 6. OTHER ELEC. 0.50 Watts/sgft FOR TOTAL 672 Watts 7. MISC. SENSIBLE _ 0 Btuh SCHEDULE NUMBER : 0 LATENT - ' 0 Btuh SCHEDULE NUMBER : 0 *���••x•�•��t**�*��•�t•�•*��t*4•x•at�aa�•�•-�i••��•�•�•�•�•�•��taa���*•�•gat•��-*�•��••��•*at•�**•�*at�at•�t•�•�t•�at•�•�•�t�t•�at•�t••*�i Pg 2 • INPUT DATA FOR.H&.S MANAGEMENTeRESIDENCE WALL AREAS (sq rt) BY TYPE AND EXPOSURE EXPOSURE TYPE 1 TYPE 2 TYPE 3 TOTAL ------------------------------------------------------------------------------------ NE 0 0 0 0 E 64 0 0 64 SE. 0 0 0 0 S 317 0 0 317 SW 0 0 0 0 W 224 0 0 224 NW 0 0 0 0 N 324 0 0 324 -----^------------------------------------------------------------------------- .b TOTALS 929 0 0 929 �••x•�t••x••�• •�• •x•* �••�••x• �• •�•�• �••� •�• �••x• •x• •x••x••x••�•�• •� �••x•�• �c••� �• •�• •�• �• �• �• �• •x• �• •x• •x• •� �• •x• •�• •x• •� •x• •x• •� �•� �• �• •� •x• •x• �• �c• •� � �• •�• •x• •x••x• •� * �• •� •x• * �t• �• •x• •� GLASS AREAS AND SHADING TYPES B,Y GLASS TYPE AND EXPOSURE e <--GLASS TYPE i —> <•--GLASS TYPE 2 —> <—•—GLASS TYPE 3 —> AREA SHADE AREA SHADE AREA SHADE TOTAL AREA EXP. (sgft) TYPE (sgft) TYPE (sgft) TYPE (sgft) ------------------------------------------------------------------•------------ NE 0 0 0 0 0 0 0 -E 16 1 0 0 0 0 16 SE 0 0 0 0 0 0 0 S 0 0 42 2 40 3 82 SW 0 0 0 0 0 0 0 W 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 N 24 1 36 2 0 0 60 H. 0 0 0 0 0 0 0 --------------------------------------------------------------------------- TOTALS 40 78 40 1.58 •* •��•� at••�••��t•�•at••�tet•at�•aa•�••�t••�a •�• •�•�••�• •x••�• •�• �••tt•�••�••�• •� mat• �t• •�t �t• •�• •�••�• �• •�• •� •x• •�• •x• at •�t -�aaaa •x• •�t• �••�• •� at at• •� •� •� �••�t• •�• # •�• as •�• •�• •x••�•�• •�• •�••� •�r•�••� INPUT ECHO FOR: - H&S MANAGEMENT ;I JOB NAME: LA QUINTA DATE PREPARED 12/ 9/85 20615842.0*��*��a�aaaa���x -Dailyhours of system operation = 24 ------------------------------------------------------------------------- Indoor Air Data: Cooling Season — Dry Bulb = 75 F Wet -Bulb = 63 F Rel. Humidity = 51 Heating Season — Dry Bulb = 68 F ---------------------------•----------------------------------------------- Supply Data:. ''Cooling Season — Supply Air Temperature — 57 F Heating Season — Supply Air Temperatures ------------------------------------ 110 F y - --------------------------- --------------------------Supply Fan Data: Supply Estimated fan static pressure = 0.50 in. Fan type #= 2.) Blow—Thru -----------------------------------------------------------------=------- Ventilation Air Data: t Cooling Season — Total Cfm = 67 Cfm Heating Season — Total Cfm = 67 Cfm ---------------------------------------------------- --------�,a Plenum Data; ' Does return air flow through plenum ? N?.' ------------------------------------------------------------------------- Safety Factors: " Cooling = 10 Heating Warm-up = 20 F LIST OF SPACES INCLUDED IN ZONE Name Mult Name Mult 1 (C) H&S MANAGEMENT,RESIDENCE x 1 --------------- Safety Factors: Cool irig = 10 Heating Warm—up = 30 ----------------------------------------------------------------------------- LIST OF SPACES INCLUDED IN ZONE Name Mult Name Mult 1 (C) H&.S MANAGEMENT,RESIOENCE x: 1 •�••x• •� •ii• �• at• •� •x•-�c• •�`•�• •� � •�•*•� •� •�t•at•-x• * •� �• •� •�c• �• �• •� •x• •�• � •�t• �t• ��t• •� ae •� •� •� �- at• at• •� •:e ac• •� •x• �• •� � •� �t••�• * •� * � * � •� * * •�t•�• �• �• •� ac• •� at• •� •� •� INPUT ECHO FOR: • H&S MANAGEMENT JOB NAME: LA QUINTA' DATE_ PREPARED 12/ 9/85 M�x�t*�M�x**31*x*�t�s•*x� 20615842.0���•�*�*�*atx�*��t Daily hours of system oper•ati�en = 24 ------------------------------------------------------------------------------------- Indoor Air Data: Cooling Season — Dry Bulb = 75 F Wet Bulb = 63 F Rel. Humidity = 51 Heating Season — ------------------------------------------------------------------------- Dry Bulb = 68 F Supply Data: Coaling Season — Supply Air Temperature = 57 F Heating Season — ----------------------------------------------------------------------------- Supply Air Temperature = 110 F Supply Fan Data: A Estimated fan static pressure — 0.50 in. Fan type _ 2) Blow—Thru ----------------------------------------------------------------------------- Ventilatiori Air Data: Cooling Season — Total Cfm = 67 Cfm Heating Season — Total Cfm — 67 Cfm Plenum Data: Does return air flow through plenum ? N --------------- Safety Factors: Cool irig = 10 Heating Warm—up = 30 ----------------------------------------------------------------------------- LIST OF SPACES INCLUDED IN ZONE Name Mult Name Mult 1 (C) H&.S MANAGEMENT,RESIOENCE x: 1 •�••x• •� •ii• �• at• •� •x•-�c• •�`•�• •� � •�•*•� •� •�t•at•-x• * •� �• •� •�c• �• �• •� •x• •�• � •�t• �t• ��t• •� ae •� •� •� �- at• at• •� •:e ac• •� •x• �• •� � •� �t••�• * •� * � * � •� * * •�t•�• �• �• •� ac• •� at• •� •� •� SINGLE.HOUR LOAD CALCULATION OUTPUT FOR Aug. 5 PM; H&.S MANAGEMENT JOB NAME: LA GUINTA DATE PREPARED: 12/ 9/85 SITE NAME: LA Q%UINTA CA. 30615842.0 OUTDOOR DB/WB: 112.0/ 80.0 F INDO(:)R 'DB: 75.0 F RH: 51 x••�•�•�•�•M••�•�•��••���•�•�•�•*�•�•�#ars••��a�•x•�•x•as••��•�•�•M•a�•�•�•�•�a�•�•�•�•�•x-�•�•�•�a�•�•�#•�•��•a�•�•� Element by Element Loads For H&S MANAGEMENT%RESIDENCE Element . Description E WALL ---> Sens 174 Btu/hr .Area : 64 sgft U—Val : 0.080 Btu/hr/sgft/F Eqv. dT 34.0 F S WALL ---> Sens 19065 Btu/hr- Area 317'sgft U—Val : 0.080 Btu/hr/sgft/F Eqv. dT 42.0 F W WALL ---> Sens 1x039 Btu/hr Area 224 sgft U—Val : 0.080 Btu/hr/sgft/F Eqv. dT 58.0 F N WALL --->. Sens 855 Btu/hr Area 324 sgft U—Val : 0.080 Btu/hr/sgft/F Eqv. dT 33.0 F ROOF ------ > Sens 1,976 Btu/hr Area 19344 sgft U—Val 0.030 Btu/hr/soft/F Eqv. dT 49.0 F Exposed to Sun 0 % of load to plenum 100 % of load to space E GLASS --> Sans 1•-)038 Btu/hr Area 16 sgft U—Val 1.130 Br_i.,/hr/sgft/F Eqv, dT 37.0 F Bare Glass / External Shade Glass Factor.: 1.000 PSHG(Btu/hr/sq ft) Exposed . 192.1 Shaded 12.9 Trans: 669'Bt'u/hr Solar 369 Btu/hr N GLASS --> Sens 1,307 Btu/hr Area 24 sgft U—Val . 1.130 Btu/hr/sgft/F Eqv". dT 37.0 F Bar•. Glass / External Shade Glass Factor ': '1.000 PSHG(B'tu/hr/sq ft) Exposed 12.9 Shaded 12.9 Trans: 19003 Btu/hr Solar : 303 Btu/hr S GLASS --> Sens 3,382 Btu/hr Area : 42 sgft U—Vat : 1.130 Btu/hr/sgft/F Eqv. dT 37.0 F Bare Glass / External Shade Glass Factor : 1.000 PSHG(Btu/hr/sq ft) Exposed 92.2 Shaded 12.9 N GLASS --> Sens 19960 Btu/hr Area 36 sgft U—Val 1.130 Btu/hr/sgft/F Eqv. dT 37.0 F Bare Glass / External Shade Glass Factor : 1.000 PSHG(Btu/hr/sq ft) Exposed 12.9. Shaded 12.9 Trans: 19505 Btu/hr Solar 455 Btu/hr S GLASS --> Sens 39221 Btu/hr Area 40 sgft U—Val :1.130 Btu/hr/sgft/F Eqv, dT 37.0 F Bare Glass / External Shade Glass Factor : 1.000 PSHG(Btu/hr/sq ft) Exposed 92.2 Shaded 12.9 Trans: 1,672 Btu/hr Solar 1,549 Btu/hr PARTITION —> Sens : 461 Btu/hr Area 144 sgft U—Val : 0.0£30 Btu/hr/sgft/F Cooling dT 40 F Heating dT : —20 F LIGHTS ----> Sens 2,294 Btu/hr Watts/sq ft : 1.00 Floor Area : 11344 sq ft Schedule Pct 50 % Total . 672 Watts Lights Incandescent 0 % of load to plenum 100 % of load to space PEOPLE ----> Sens : 1,225 Btu/hr L.at 1%025 Btu/hr Sq ft/person 269 Floor Area 1,344 sq ft Schedule Pct 100 % Total . 5 people Sensible : 245 Btu/hr/per Latent : 205 Btu/hr/per INFIL. ----> Sens : 2,735 Btu/hr Lat : 1,734 Btu/hr Rate:0.05 cfm/sgft Floor Area: 19344 sgft Temp. diff:37.0 F Sp. humidity diff:0.'0053 lb/lb OTHR ELEC —> Sens 1,147 Btu/hr Watts/sq ft 0.50 Floor Area : 19344 sq ft Schedule Pct : 50 % Total . 336 Watts SINGLE_ HOUR LOAD CALCULATION OUTPUT FOR Aug. 5 PM; H&.S MANAGEMENT JOB NAME: LA QUINTA DATE PREPARED: 12/ 9/85 SITE NAME: LA QUINTA CA. 30615842.0 OUTDOOR DB/WB: 112.0/ 80.0 F INDOOR DB: 75.0 F RH: 51 Zone Loads & Systerti Information Summary LOAD COMPONENT SENSIBLE(Btu/hr) LATENT(Btu/hr) --------------------------------------------------------------- SOLAR GAIN 41303 0 GLASS TRANSMISSION 6+606 0 WALL TRANSMISSION 3,134 0 ROOF TRANSMISSION 19976 0 TRANS. LOSS TO UNCOND. SPACE 461 0 LIGHTING ( 672 W TOTAL.) 2%294 0 OTHER ELEC. ( 336 W TOTAL) 1,147 0 PEOPLE ( 5 PEOPLE TOTAL.) 1 , 225 1, 025 MISCELLANEOUS LOADS 0 0 COOLING INFILTRATION 21735 1+734 COOLING SAFETY BTU's .'.`'_,388 276 SUB—TOTALS 261267 39035 NET VENTILATION AIR LOAD 2.,727 1,560 SUPPLY FAN LOAD (BHP= 0.2) 582 0 ROOF LOAD TO PLENUM 0 0 LIGHTING LOAD TO PLENUM ----------------------------------------------------------------- 0 0 TOTAL COOLING LOADS '9,577 4+594 TOTAL COOL-ING LOAD = 34, 171 Btu/hr; or 2.85 ton; or 472.0 sq ft/tun ZONE TOTAL FLOOR AREA = 1,344 sq ft. •�. •*.�••�.•�• •�. •� •� •�•�•.�•.�•.�•.M. •* •*.�• •�•.�• •*.�•.�••�• •�••�• •� •x•-�• •*at •oaf •�• �• •�• at• •�-•x• •�• •� of •�t• •x• aE •�• �• •� •�t •�•.�• •* •�••�• * •�••�• •� � •� � TRANSMISSION AND SOLAR GAIN BY EXPOSURE LOAD COMPONENT AREA TRANSMISSION SOLAR GAIN (sq ft) <Btu/hr) (Btu/hp) GLASS LOADS: NE 0 0 0 E 16 669 369 SE 0 0 0 S 82 3, 4'8 39175 SW 0 0 0 W 0 0 0 NW 0 0 0 N 60 2v5O9 759 H 0 0 0 ...WALL LOADS: NE 0 0 — E 64 174 — SE 0 0 — S 317 1,065 — SW' 0 0 — W 224 1,039 — NW 0 0 — N 324 855 — •�.•�•�. •x• •�•:t• �••�• •� •�• •x• •� •,raF •� •x• aEaE aF•�• •� �• •�.•* •*•�. •* •* •�. •jt• •* •x• •�• •� •�• •� •�• •�• •�•� at •�• •* •�• •�• •�• •� •�• •�• •� •�• aa• ac• •� •�• ae •� �t �aF COIL SELECTION PARAMETERS COIL ENTERING AIR TEMP. (DB/WB) _ 77.3/ 64.9 deg F COIL LEAVING AIR TEMP. (DB/WB) = 57.0/ 56.4 deg F •COIL SENSIBLE LOAD _ 29,577 Btu/hr COIL_ TOTAL. LOAD — 34, 171 Btu/hr COOLING SUPPLY AIR TEMPERATURE — 57.0 deg F TOTAL COOLING CFM = 1,327 Cfm COOLING CFM%SQFT _ 0:99 Cfm/sgft RF_SULT I NG ROOM REL_:. HUMIDITY = 53 •��•a�•����•�-�•�•�•�•�•�•��-•�•�•��•iF•�•iF•�•�•��••�a�••�•��••�a••�aE••�•x••�a�•gas•�•a��a•�•�-�•�•�•�•���••�•�•�•�•�•��r HEATING LOAD CALCULATION OUTPUT H&S MANAGEMENT JOB NAME: LA GUINTA DATE PREPARED: 12/ 9/85 SITE NAME: LA QUINTA CA. 20615842.0 WINTER DESIGN DRY BULB: 29.0 F= INDOOR DB: 68.0 F HEATING LOAD SUMMARY Note; Heating load it computed at Winter design condition. LOAD COMPONENT LOAD (Btu/hr) ---------------------------------------------------------------- WALL TRANSMISSION 2,898 ROOF TRANSMISSION 11572 GLASS TRANSMISSION 6%963 TRANSMISSION LOSS TO UNCOND. SPACES 230 INFILTRATION LOSS 2,883 SLAB FLOOR 3,901 HEATING SAFETY BTU'S 5,534 ------------------------------------------------- SUB—TOTAL 23%982 NET VENTILATION LOSS 29874 TOTAL HEATING LOAD 26x857 HEATING SUPPLY CFM 519 Cfm HEATING SUPPLY AIR TEMPERATURE 110.0 Sieg F HEATING VENTILATION•AIR CFM 67 Cfm HEATING SEASON ROOM DRY BULB TEMP. 68 des F