14824 (SFD)t
P.O. BOX 1504
Building 53-960 Ave. Herrera 78-495 CALLE TAMPICO
Address LA QUINTA, CALIFORNIA 92253
Owner
Double 0 Construction
Mailing
Address 51-960 Ave. Herrera
City Zip Tel.
. La. Quinta, .CA 92253 771-1563
Contractor
same
. Address
Zip I Tel.:
State Lic. City
& Classif. S 681012 • Lic. # 323
Arch., Engr.,
Designer
Address Tel.
City lZip I State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
000) of Divisions3 of the Business and Professions Code,,la1nd my license is In fullyfcorcand
(fact f t'"Yi AG4 i l J_(_
SIGNATURE Y r DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
- .reason: (Sec. 7031.5,Bustness and Professions Code: Any city or county which .requires a
permit to construct, after, improve, demolish, or repair any structure, prior to Its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to
the provisions or the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of notmore than rive hundred dollars ($500).
❑ I, as owner of, the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does, not apply town owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.) -
0 1, as owner of the property, am exclusively contracting with licensed contractors. to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's, License Law
does not apply to an, owner of property who builds or Improves thereon, . and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec B. & P.C. for this reason r
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy N Company
twicopy is filed with the city, O Certified copy is hereby furnished. .
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE t
(This section need not be completed If the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
=any parson In any manner so as to become subject to the Workers' Compensation
Laws of California
Date Owner
NOTICE TO APPLICANT: ff, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND
SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE
HUNDRED THOUSAND DOLLARS.($100,000), IN ADDITION TO THE COST -OF COMPENSATION,
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND
ATTORNEY'S FEES.
This Is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days:
1 certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives. -of .this city to enter the above-.
mentioned property for inspection purposes.' '
Signature of applicant Date
Mailing Address
City, State, Zip
I
No. 14824
I
BUILDING: TYPE CONST.STN OCC.
GRP. .R3
A.P. Number 77zl'/0( s`--
Legal Description—1,/3 bul
Project Description
REMARKS
ZONE: BY:
Minimum Setback Distances:. MAR 2 1igq
)
Front Setback froCen er Line ``'
Rear Setback fron Rear Prop. Line U
Side Street Setb cByom Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:' Date Permit
Validated by:
Validation:
Sq. Ft.
Size 1420
"No.
Stories
No. Dw.
Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
does
not include
cove'redj patio, -
—Permit
block wall,
or pool.
Estimated Valuation
$86,352.00
PERMIT
AMOUNT
Plan Chk. Dep.
250.00
•
Plan Chk. Bal.
260.62
Const.
581.00
Mech.
55.50
Electrical
121.40
Plumbing
138 00
S.M.I.
8.51
Grading
20.00
Driveway Enc.
00
Infrastructure
1015.70
Precise Plan
25.00
TOTAL
3,375.73
3,125.7.3
REMARKS
ZONE: BY:
Minimum Setback Distances:. MAR 2 1igq
)
Front Setback froCen er Line ``'
Rear Setback fron Rear Prop. Line U
Side Street Setb cByom Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:' Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING; FEES
1ST FL. SO. FT. ® $
UNITS
SLAB GRADE -/ 9�
ROUGH PLUMB.
BONDING
YARD SPKLR SYSTEM
2ND FL. SO. FT. 0
FORMS J C5
EWE O SEPTIDT
ROUGH WIRING
MOBILEHOME SVC.
BAR SINK
FOR. SO. FT. ®
GAS (ROUGH)
METER LOOP
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
GAS (FINAL)
TEMP. POLE
DRAINAGE PIPING
CAR P. SO. FT.
GROUT
WATER HEATER
WALL SO. FT. ®
FINAL INSP.
DRINKING FOUNTAIN
SO. FT. ®
WATER SYSTEM
URINAL
ESTIMATED CONSTRUCTION VALUATION $
=$
WATER PIPING
NOTE: Not to be used as property tax valuation
f FINAL INSP.
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE,TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID 0 114 c
SEWAGE DISPOSAL
INSULATIONISOUND
FINISH GRADING
SO.FT.GAR ® 3/ac
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK l
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE -/ 9�
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS J C5
EWE O SEPTIDT
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF. 'Y /9
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
f FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
A
0
rn
G
r
_
ITI T-
oAN3m�
�Azm
TOO
m
Cl
mm
A
m
m
rDuj
zD
A
TJ1
DDD�
"Dry 0
m0N�
?o
mm0
AMD
�DL
DDG�
LF
OzDm
NzA
-mum
ONZ
mn�
DO
A
w
DDT
G��O
mz
� N 1
�Xc
O
�Or
N
NDO
3rr
�Oo
mrU3
Z -0 T
P_nO
O
A
1
A N
Om
z
mzZ
z��
A0�
7C
tp�rG�
ZOM
AEr
A03m
1>
r= O
z
G�
cC
D
N
(P -n
mD
Nn
U�
-A
OD
TITLE 24 REPORT FOR:
D D 1421 SQ. FT.
LA QUINTA, CA.
PROJECT DESIGNER:
D D CONSTRUCTION
51-960 AVENIDA HERRERA
LA QUINTA, CA.
(619) 771-1561
REPORT PREPARED BY:
R.Krown, CEA R92-93 204
KROWN MECHANICAL DESIGN
P.O.BOX 1761
LA QUINTA, CA 92253
(619) 773-2623
Job Number: 95007R
Date: 3/16/1995
Asaly•t
rr
A ��s
CA■EC
Cs�'rya ��� d D�3+o �„q, CoNuwinre
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential Building Energy Efficiency Standards.
This program developed by Gabel Dodd Associates (510) 428-0803.
Table Of Contents for Title 24 Report
--------------------------------------
CoverPage
... ..................... -• ...... ............................
1
Table
of Contents
............ ............... ,.........................
2
Form
CF-1R
Certificate of Compliance: Residential ....................
3
Form
MF-1R
Mandatory Measures Checklist: Residential ................
5
Form
C-2R
Computer Method Summary ......................................
7
Form
ENV-3
Construction Assemblies ........ ..........................
10
I�
QERTIFICATE OF COMPLIANCE: Residential. (part .1 of 2) CF-1R page 3 of 12
---------------------------------------------------------------------------
Project Name: D D .1421 SQ. FT. Date: 3/16/.1995
Address:
LA QUINTA. CA. ;Building Permit No
i
i
Designer: D D CONSTRUCTION ;Checked by / Date
i
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
----------------------------------------------------------------------------
GENERAL INFORMATION
Compliance Method: COMPLY 24 version 4.11
Climate Zone: 15
Conditioned Floor Area: 1421 sgft
Building Type: Single Fam Det
Building Front Orientation: 180 deg (S)
Number of Dwelling Units: 1
Floor Construction Type: Slab on Grade
BUILDING SHELL INSULATION
Component U-Value Location/Comments
R-13 Powerwall (2x4.16) 0.060 WHOLE HOUSE
R-13 Partition (2x4„16) 0.085 WHOLE HOUSE
Built-up/Air/R-38/Gypbd 0.024 WHOLE HOUSE
Slab Perimeter w/R-0.0 0.720 WHOLE HOUSE
Slab Perimeter w/R-0.0 0.900 WHOLE HOUSE
FENESTRATION Shading Devices Frame
Orient. Area U-Val Type Interior Exterior OH SF Type
Back (N) 38.0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal
Right (E) 20.0 0.60 Double Opaque White R1 Standard Bug Scr N N Wood
Front (S) 20.0 0.60 Double Opaque White R1 Standard Bug Scr N N Wood,
Front (S) 20.0 0.60 Double Opaque White R1 Standard Bug Scr Y N Wood
Front (S) 6.0 0.87 Double Std Drape Standard Bug Scr Y N Metal
Front (S) 42.0 0.87 Double Opaque White R1 Standard Bug Scr N N Metal
Front (S) 12.0 1.40 Double Std Drape Standard Bug Scr N N Metal
Left (W) 40.0 0.77 Double Std Drape Standard Bug Scr N N Metal
Skylight 8.0 0.80 Double none none N N Metal
THERMAL MASS Area Thick
Type Covering (sf) (in) Location/Description
Concrete, Heavyweight Covered 1253 3.50 Slab on Grade
Concrete, Heavyweight Exposed 168 3.50 Slab on Grade
CERTIFICATE OF COMPLIANCE: Residential (part 2 of 2) CF-1R page 4 of 12
• Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
r
r
Documentation: !CROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
----------------------------------------------------------------------------
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
PackHtPump 6.600 HSPF Ducts in Attic 4.2 SetBck FAU/CU/COIL 1
PackHtPump 10.000 SEER Ducts in Attic 4.2 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R-Val
Std Gas 50 gal or Less Pipe Insulation StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R-Val Light
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
PROPANE W.H. WOOD FRENCH DOORS, 1" @ 1.5#/Sq.Ft EPS on walls
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Parts 1 & 6 of the Califor-
nia Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions
D D CONSTRUCTION
51-960 AVENIDA HERRERA
LA QUINTA, CA.
(619) 771-1561 Lic #:
Code)
ftu I Daa 2/)A&C,
(signature) (d te)
ENFORCEMENT
Name:
Title:
Agency:
Telephone:-
AGENCY
DOCUMENTATION AUTHOR
R.Krown, CEA R92-93 204
KROWN MECHANICAL DESIGN
P.O.BOX 1761
LA QUINTA, CA 92253
(619) 773-2623
(signature) (date)
(signature/stamp) (date)
MANDATORY MEASURES CHECKLIST (part 1 of 2) MF-1R page 5 of 12
-----------------------------------------------------------------------------
Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
` a
' Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents; the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
o Sec. 150(a): Minimum R-19 ceiling insulation. *
o Sec. 150(b): Loose fill insulation manufacturers
labeled R-Value.
o Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls). *
o Sec. 150(d): Minimum R-13 raised floor insulation in framed
floors; Minimum R-8 in concrete raised floors. *
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & form.
Enforcement
o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label w/certified U-Value
c. Exterior doors and windows weatherstri.pped; all joints
and penetrations caulked and sealed.
o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150(f): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards.
o Sec. 150(e): Installation of Fireplaces, Decorative Gas
Appliances and Gas Logs
1: Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF-1R page 6 of 12
----------------------------------------------------------------------------
Project Name: D D 1421 SQ. FT. :Date: 3/16/199.5
i
z
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
---------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 150(i): Setback thermostat on all applicable
heating systems.
o Sec. 150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (eg unfired storage tanks or
backup solar hot water tanks) have insulation blanket
(R-12 or greater) or combined interior/exterior insulation
(R-16 or greater).
2. First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposed piping insulated in recirculation
sections of hot water system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and indirect hot
water tank.
o Sec. 150(m) Ducts and Fans
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers.
o Sec. 114:Pool and Spa Heating Systems and Equipment
1. System is certified with 78510 thermal efficiency, on -off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36" pipe between Filter and heater for future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas -fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150(k): Lighting - 40 lumens/watt or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY
C-2R
page 7 of 12
Project Name: D D 1421 SQ. FT.
;Date:
3/16/1995
Documentation: KROWN MECHANICAL DESIGN
i
;COMPLY
24 User 2366
Standard
Proposed
Compliance
Source Energy Use (KBtu/sf-yr)
Design
Design
Margin
Space Heating
4.83
4.17
0.67
Space Cooling
33.77
34.52
-0.74
Domestic Hot Water
14.70
13.91
0.79
TOTALS
53.31
52.59
0.72
*** BUILDING COMPLIES ***
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
COMPLY 24 version 4.11
15
1421 sqf t
Single Fam Det
180 deg (S)
1
1
Slab on Grade
14210 cuft
1421 sqf t
1421 sqf t
BUILDING ZONE INFORMATION
Floor # of Vent
Zone Name Area Volume Units Zone Type TStat Type Hgt Area
FAU/CU/COIL 1 1421 14210 1.00 Conditioned Setback 2 n/a
OPAQUE SURFACES Act Solar
Type Area U-Val Azm Tilt Gains Form 3 Reference Location/Comments
ZONE NAME = FAU/CU/COIL 1
Wall
445
0.060
180
90
Yes
R-13
Powerwall
(2x4.16)
WHOLE
HOUSE
Wall
313
0.060
270
90
Yes
R-13
Powerwall
(2x4.16)
WHOLE
HOUSE
Wall
372
0.060
0
90
Yes
R-13
Powerwall
(2x4.16)
WHOLE
HOUSE
Wall
128
0.060
90
90
Yes
R-13
Powerwall
(2x4.16)
WHOLE
HOUSE
Wall
135
0.085
0
90
Yes
R-13
Partition
(2x4.16)
WHOLE
HOUSE
Wall
210
0.085
90
90
Yes
R-13
Partition
(2x4.16)
WHOLE
HOUSE
Roof
1413
0.024
180
0
Yes
Built-up/Air/R-38/Gypbd
WHOLE
HOUSE
1
i a
1 r
COMPUTER METHOD SUMMARY
C-2R page 8 of 12
Project Name: D D 1421
SQ. FT.
;Date: 3/16/1995
Documentation: KROWN MECHANICAL
---------------------------------------------------------------------------
DESIGN
i
;COMPLY 24 User 2366
PERIMETER LOSSES
F2
Insulation
Type Length
Factor
R-Val Depth
Location/Comments
ZONE NAME = FAU/CU/COIL
1
Covered 155.0
0.72
0.0 0 in
WHOLE HOUSE
Exposed 24.5
0.90
0.0 0 in
WHOLE HOUSE
FENESTRATION SURFACES
Act
#
Type
Area
Frame
Div
U-Val
Azm
Tilt
ZONE NAME =
FAU/CU/COIL
1
1
Wdw
Front
(S)
12„0
Metal
No
1.40
180
90
2
Wdw
Front
(S)
12.0
Metal
No
0.87
180
90
3
Wdw
Front
(S)
20.0
Wood
No
0.60
180
90
4
Wdw
Front
(S)
30.0
Metal
No
0.87
180
90
5
Wdw
Front
(S)
20.0
Wood
No
0.60
180
90
6
Wdw
Front
(S)
6.0
Metal
No
0.87
180
90
7
Wdw
Left
(W)
40.0
Metal
No
0.77
270
90
8
Wdw
Back
(N)
6.0
Metal
No
0.87
0
90
9
Wdw
Back
(N)
16.0
Metal
No
0.87
0
90
10
Wdw
Back
(N)
16.0
Metal
No
0.87
0
90
11
Wdw
Right
(E)
20.0
Wood
No
0.60
90
90
12
Sky
Front
(S)
8.0
Metal
No
0.80
180
0
SC
Glass
Only Location/Comments
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.86
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.88
WHOLE
HOUSE
0.63
WHOLE
HOUSE
INTERIOR
& EXTERIOR SHADING
#
Type
Interior Shade Type
SC
Exterior
Shade Type
SC
1
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
2
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
3
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
4
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
5
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
6
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
7
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
8
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
9
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
10
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
11
Wdw
Opaque White
Rlr
Shade
0.40
Standard
Bug
Screen
0.87
12
Sky
None
1.00
None
1.00
0
COMPUTER METHOD SUMMARY C-2R page 9 of 12
---------------------------------- - --- - ---------------------------------
Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
I� Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
f-- ------__--------------__----------------------------------------------------
OVERHANGS/SIDE FINS
--Window--
# Type Ht Wd
5 Wdw 6.7 3.0
6 Wdw 2.0 3.0
-----Overhang-------
Len Ht LExt RExt
7.0 0.1 7.0 7.0
7.0 0.1 7.0 3.5
---Left Fin--- ---Right Fin --
Dist Len Ht Dist Len Ht
THERMAL MASS Area Thick Heat Inside Location
Type (sf) (in) Cap Cond Form 3 Reference R-Val. Comments
,ZONE NAME = FAU/CU/COIL 1
Covered Slab 1253 3.50 28 0.98 n/a 2
Exposed Slab 168 & SO 28 0.98 n/a O
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
PackHtPump 6.600 HSPF Ducts in Attic 4.2 SetBck FAU/CU/COIL 1
PackHtPump 10.000 SEER Ducts in Attic 4.2 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R-Val
Std Gas 50- gal -or-Less Pipe Insulation StorGas _ '1 0.53 50.0 -12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R-Val Light
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
PROPANE W.H. WOOD FRENCH DOORS, 1" @ 1.5#/Sq.Ft EPS on walls
r
0
PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 10 of 12
---------------------------------------------------------------------------
Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
I
Documentation:
_-KROWN- MECHANICAL -DESIGN
--- ---;COMPLY-24-User-2366
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
Assembly Name: R-13 Partition (2x4.16)
Assembly Type: Wall.
Assembly Tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: O.C.
Framing Percent: 15.0
Absorptivity: 0.20
Roughness: Smooth Plaster, Metal
ASSEMBLY U-VALUE
Th
R-Value
Construction Components
Fr
(in)
Cavity
Frame
---------------------------------------------------------------------------
Outside Air Film
0.17
0.17
1. Gypsum or Plaster Board
0.625
0.56
0.56
2. Membrane, Vapor -Seal, Plastic Film
0.010
0.06
0.06
3_ Insulation, Mineral Fiber, R-13
*
3.500
13.00
3.46
4. Gypsum or Plaster Board
0.500
0.45
0.45
S.
6.
7.
8.
9_
Inside Air Film
0.68
0.68
---------------------------------------------------------------------------
Unadjusted
R-Values
14.92
5.39
ADJUSTMENT FOR FRAMING
(1 /14.92) x (0.85) + (1 / 5.39) x (0.15) =
0.085
TOTAL
U-VALUE
=
0.085
TOTAL
R-VALUE
=
11.79
Weight: 6.4 lb/sqft
Heat Capacity: 1.86
PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 11 of 12
---------------------------------------------------------------------------
Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Assembly Name: R-13 Powerwall (2x4.16)
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: __" O.C.
Framing Percent: 15.0
Absorptivity: 0.70
Roughness: Stucco, Wood Shingles
Th
R-Value
Construction Components
---------------------------------------------------------------------------
Fr
(in)
Cavity
Frame
Outside Air Film
0.17
0.17
1. Stucco
0.875
0.17
0.17
2_ Membrane, Vapor -Seal, Plastic Film
0.010
0.06
0.06
3. Insulation, 1-1/2# E.P.S.
1.000
4.63
4.63
4. Insulation, Mineral Fiber. R-13
*
3.500
13.00
3.46
5_ Gypsum or Plaster Board
0.500
0.45
0.45
6.
7.
s.
9.
Inside Air Film
---------------------------------------------------------------------------
0.68
0.68
Unadjusted
R-Values
19.17
9.63
ADJUSTMENT FOR FRAMING
(1 /19.17) x (0.85) + (1 / 9.63) x (0.15) =
0.060
TOTAL
U-VALUE
=
0.060
TOTAL
R-VALUE
=
16.69
Weight:
Heat Capacity:
12.4 lb/sqft
2.91
' FROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 12 of 12
---------------------------------------------------------------------------
Project Name: D D 1421 SQ. FT. ;Date: 3/16/1995
i
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION Assembly Name: Built-up/Air/R-38/Gypbd
Assembly Type: Roof
Assembly Tilt: 0 deg (Horizontal Roof)
Framing Material: Wood
Framing Spacing: _" O.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
-------------------------------
Sketch of Construction Assembly
Roughness:
Concrete, Asph.
Shingles
ASSEMBLY U-VALUE
Th
R-Value
Construction Components
--____-------------------------------------------------------------------------------
Fr (in)
Cavity
Frame
Outside Air Film
0.17
0.17
1. Roofing, Built -Up
0.375
0.33
0.33
2. Plywood
0.625
0.77
0.77
3. Air Space
* 12.000
0.80
11.88
4. Insulation, Mineral Fiber, R-38
11.500
38.00
38.00
5. Gypsum or Plaster Board
0.500
0.45
0.45
6.
7.
8.
9.
Inside Air Film
0.61
0.61
---------------------------------------------------------------------------
Unadjusted
R-Values
41.13
52.21
ADJUSTMENT FOR FRAMING
(1 /41.13) x (0.90) + (1 /52.21) x
(0.10) =
0.024
TOTAL U-VALUE
=
0.024
TOTAL R-VALUE
=
42.03
Weight:
Heat Capacity:
10.1 lb/sqf t
3.28