07-2931 (RER)j,_ 1" .
P.O.-50X 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Ti&t 4 4 a"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number:
07-00002931
Property Address:
77495 CALLE HIDALGO
APN:
773-124-025-2 .-000000-
Application description:
REMODEL - RESIDENTIAL
Property Zoning:
COVE RESIDENTIAL
Application valuation:
35000
Applicant: Architect or Engineer
ala
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: License No.:
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
(�) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State license w.).
( ) 1 am exempt under P. `Seec. , B.& . for his re/on
ate: :O d ner:
CONSTRUCTIONENDING AGENCY
I hereby affirm under penalty of perjury that there is a constructs n lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
DANIEL & CARMEN JON]
77-495 CALLE HILDAL(
LA QUINTA, CA 92253
Contractor:
Owner
fw.b.: ��sb��m8• 14C
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/20/07
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier Policy Number
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner sofis4o become ubject to the workers' compensation laws of California,
and agree that, if I sho d be om u ct to the workers' compensation provisions of Section
/ 3,7y0�0 of the Labor C e, I all r ith comply with those provisions.
te:
WARNING: FAILURE TO SECURE WORKERS' COPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTf SAND CIVIUFINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such per' or cessati n of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the ove info o is correct. I agree to comply with all
city and county ordinances and state laws relating to buil g constr nd hereby authorize representatives
of this county to,enter upon above-mentioned prope for ins rposes.
."ate: `1VId D nature (Applicant or Agent):
LQPERMIT
Application Number . . . . . 07-00002931
------ Structure Information RES REMODEL W/1,089SF PATIO COVER
-----
Other struct info . .
. . . CODE EDITION 2001/2004/2005
----------------------------------------------------------------------------
# BEDROOMS
1.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee* . . . .
317.00 Plan Check Fee
206.05
Issue Date
Valuation
35000
Expiration Date
6/17/08
. Qty Unit Charge
Per
Extension
BASE FEE
252.00
10.00 . 6.5000
----------------------------------------------------------------------------
THOU BLDG 25,001-50,000
65.00
Permit
ELECT'- ADD/ALT/REM
Additional desc .
Permit Fee . . . .
92.88 Plan Check Fee
14.88
Issue Date . . . .
Valuation
0
Expiration Date
6/17/08
Qty Unit Charge
Per
Extension
BASE FEE
• 15.00
2225.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
77.88
.00 .0200
-------------------------------------
ELEC GARAGE OR NON-RESIDENTIAL
--------------------------------------
.00
Permit . .
MECHANICAL
Additional desc .
Permit Fee
26.00 Plan Check Fee
6.50
Issue Date . . . .
Valuation . . . .
0
Expiration Date
6/17/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT
4:50
1.00 6.5000
----------------------------------------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit
PLUMBING
Additional desc .
Permit Fee
33..00 Plan Check Fee
8.25
Issue Date . . . .
Valuation . . . .
0
Expiration Date
6/17/08
Qty Unit Charge
Per
Extension
., Application Number . . . 07-00002931
Permit . . . . . . PLUMBING
Qty Unit, Charge Per
Extension
BASE FEE
15.00
3.00 6.0000 EA PLB FIXTURE
18.00
----------------------------------------------------------------------------
Special Notes and Comments
RESIDENTIAL REMODEL WITH 412SF CARPORT,
677SF PATIO COVER ADDITION. [ENGINEERED]
2001 CBC, 2004 CEC, 2005 -ENERGY. THIS
PERMIT DOES NOT INCLUDE BLOCKWALLS OR
DRIVEWAY APPROACH. December 20, 2007
9:05:13 AM AORTEGA FOR JJOHNSON
----------------------------------------------------------------------------
Other Fees . . . . . . . . ENERGY REVIEW
FEE
20.61
STRONG MOTION
(SMI) -.RES
3.50
Fee summary Charged Paid
----------- --
Credited
Due
-- -- - ----- - - - - ----- - - - - ---
Permit Fee Total 468.88 .00
--- - - - - ----
.00
-- - - - - - -
468.88
Plan Check Total 235.68 .00
.00
235.68
Other Fee Total 24.11 .00
.00
24.11
Grand Total 728.67 .00
.00
728.67
C
LQPERMIT
Bin #
��B
City of La Quinta
. IBuilding & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 77777012
Building Permit Application and Trackln Sheet
Pp g
I
Per it
` I
Project Address: `77-q15-
Owner's Name: V �
A. P. Number: —7 73 - I Z7 r C) -2 +
Address: 7_ yg ? Le -
Legal Description:
City, ST, Zip: lc
Contractor: N� ��L^2
Telephone -.'
Address: Sh/
Project Description:
City, ST, Zip:
f X70 12N LL/S 4,040 17 j01)
Telephone:;.._,
State Lic. # : City Lic. #:
Arch., Engr., Designer:,5&' 4T E (,') . C01VCe 10 % f
Address: '� - (� o
City, ST, Zip: L CL
Telephone: --�'(0 5l -t0d) 7
Construction Type: Occupancy:
State Lic. #:
Project type (circle one): New Add'nAlter Repair Demo
Name of Contact Person: S��/N fD
Sq. Ft.:Z2
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project: S`p
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal
Req'd
Recd
TRACKING. f I
PERMIT FEES
Plan Sets
Plan Check submitted t
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
12f.5[07
Plan Check Balance
Energy Calcs.
Plans picked up Yz z- 7
Construction
Flood plain plan
Plans resubmitted (�
Mechanical
Grading plan
2" Review, ready for correctio - s (
Electrical
Subcontactor List
Called Contact Person.
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person,
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
��U2�Il/�1�a7 11'tz'I�tao1�•J�1s NWPOOC
i nils -R c",
TELEPHONE (760) 777-7012 FAX (760) 777-7011
OWNERBUILDER INFORMATION
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified.
'For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a
permit. Building permits are not required to be signed by property owners unless they are personally performing their
own work. If your work is being performed by someone other than yourself, you may protect yourself from possible
liability if that person applies for the proper permit in his or her name.
Contractors are required by law to be licensed and bonded by the State of California and to have a business license
from the City or County. They are also required by law to put their license number on all permits for which they
apply.
If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be
aware of the following information for your benefit and protection.
If you employ or otherwise engage any persons other than your immediate family, and the work (including materials
and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or
subcontractors, then you may be an employer.
If you are an employer, you must register with the State and Federal Government as an employer and you are subject
to several obligations include State and Federal income tax withholding, federal social security taxes, worker's
compensation insurance, disability insurance costs and unemployment compensation contributions.
There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with
respect to worker's compensation insurance.
For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if
you wish, the U.S. Small Business Administration). For more specific information about your obligations under State
Law, contact the Department of Benefit Payments and the Division of Industrial Accidents.
If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their
work personally or through their own employees, without a licensed contractor or subcontractor, only under limited
conditions.
A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building
permit, erroneously implying that the property owner is providing his or her own labor and material personally.
Building permits are not required to be signed by property owners unless they are performing their own work
personally.
Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your
community or at 1020 N. Street, Sacramento, California 95814.
Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of
these matters. The building permit will not be issued until the verification is returned.
Very truly yours,
CITY OF LA QUINTA
DEPT. OF BUILDING AND SAFETY
78-495 Calle Tampico
La Quinta, CA 9223
11
OWNER'S
PROPERTY ADDRESS
D -7-A31
PERMIT NUMBER(S)
CITY OF LA QUINTA
PLAN CHECK CORRECTION LIST
South West Concepts
78-120 Calle Estado, Suite 206
La Quinta, CA 92253
(760) 564-4707
PLAN CHECK N(:;;
ADD S 78-495 Ca e Hidalgo
SCOPE OF - R Trellis Addition
December 4, 2007
FIRST CHECKNINAL
(Structural)
OCCUPANCY R-3
TYPE -OF -CONST:. V -N
The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our
professional opinion.the plans are in substantial conformance with the building codes and regulations
adopted by the CITY OF LA QUINTA and the State of California Amendment.
APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING
APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND
ASSOCIATIONS.
Plans checked by: Perry astopoulos, P�
VCA CODE GROUP
2200 W.'Orangewood Avenue, Suite 155
Orange, CA 92868
(714) 363-4700
k1
VCA File No. LQ -20451
<i
I TITLE 24 REPORT I
Title 24 Report for:
Daniel Jones addition
77-495 Avenida Hidalgo
La Quinta, CA 92253
Project Designer:
Stephen Nieto
78-120 Calle Estado Suite 206
La Quinta, CA 92253
760-564-4707
Report Prepared By:
Stephen Nieto
South West Concepts
78120 Calle Estado, Suite 206
La Quinta, CA 92253
(760) 564-4707
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATEO BY
Job Number:
Date:
11/9/2007
Mgm T
III NOV 0 9 2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.4 by EnergySoft Job Number: User Number: 5970 1
TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 9
Form WS -5R Residential Kitchen Lighting 11
HVAC System Heating and Cooling Loads Summary 12
Room Load Summary 13
EnergyPro 4.4 by EnergySoft Job Number: User Number: 5970
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
_QwieLlones _afttion
(N) 0 deg
Fuel Type:
Natural Gas
11/7/2007
Project Title
Area: 459 ft 2
Avg. U: 0.43
Ratio: 20.6%
Date
77-495 Avenida Carranza
La Qu.i.nta
Floor Area Volume
8.0
ft
Project Address
1.00
Number of Stories:
Building Permit#
bout_ hist ConcPnts
(760) 564-4707
Documentation Author
Telephone
Plan Check/Date
FgrgyPro
Compli ce Method
CA Climate 7onp. 15
Climate Zone
Field Check/Date
TDV
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.94
2.61
0.33
Space Cooling
97.53
87.62
9.92
Fans
14.13
12.45
1.68
Domestic Hot Water
0.00
0.00
0.00
Pumps
0.00
0.00
0.00
Totals
114.60
102.67
11.93
better than Standard:
Building Type: W Single Family ❑ Addition
❑ Multi Family n Existing + Add/Alt
Building Front Orientation:
(N) 0 deg
Fuel Type:
Natural Gas
Fenestration:
ft2
Area: 459 ft 2
Avg. U: 0.43
Ratio: 20.6%
Avg. SHGC: 0.30
BUILDING ZONE INFORMATION
Zone Name
Floor Area Volume
10.4
Total Conditioned Floor Area:
2,225
ft2
Existing Floor Area:
2,225
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
2,225
ft2
Average Ceiling Height:
8.0
ft
Number of Dwelling Units:
1.00
Number of Stories:
1
# of Thermostat Vent
Units Zone Type Type Hgt. Area
OPAQUE SURFACES Insulation Act. Gains Condition
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt _Y/
_�ACall� Wood— 417 _0102 R_13__R-OQ 0 90
none—None _ 20 0.500 __None_ R-0.0_ 0_ 9Il
DQot— clone_ 20 0.,.5.0.0_—Llone_ R-0 0 0_ 90
Wall Wood— —304 —0102_ —R-13 _B_0.0_ _90_ 90
Wall Wood 371x_102—B-1.3 -00 JR0 9.0
Wall Wood 434 _0102 R-13_ JR -0a —97_0 go
Rnof Wood— 2 995 0 048 RA R-0 n n n
N
Status JA IV Reference Location / Comments
IX
1X
[XI
EK
X
IN
DQ
❑
❑
❑
❑
❑
❑❑
❑❑
71
❑❑
F-1
F-1
El
❑Existing
❑Existing_
❑
1:1
❑Existing
❑
❑❑
❑
❑
❑
❑
❑
E]
Q
F-1
71
El
09-A3 EAStina Zone
28-A4 Existing_Zone
Existing_ 28-A4 Existing Zone
Existing 09-A3 Existing Inn
09-A3 Exisfinn7nne
Existing 09-A3 _ Exisiinq 7nne
Fritting 01-A14 Extstinao lone
Run Initiation Time: 11/07/07 11:13:13 Run Code: 1194462793
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:3 of 13
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Daniel Jones addition 11/7/2007
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments
1_
2
Window Front
Existing
(N)
13 3 _0_330 NFRC _021 NFRC 0_ _90- Altered_ Milgard French Door
0.790 116-A 0_70 116-B Double Metal Clear
Existing Zone
pre -altered for above
3
Window Front
(N)
27.0
0.330 NFRC 0.21 NFRC
0
90 Altered Milgard French Door
Existing Zone
4
Existing
10
Bug Screen
0.790 116-A 0.70 116-B
Double Metal Clear
pre -altered for above
5
Window Front
(N)
13.3
0.330 NFRC 0.21 NFRC
0
90 Altered Milgard French Door
Existing Zone
6
L
Existing
Window Front
(N)
32.00
0.790 116-A 0_70 116-B
333 NFRC0 26 NFRC
0
Double Metal Clear
90 Altered Milgard casement
ore -altered for above
Existing Zone
8
Existing
Bug Screen
0.790 116-A 0.70 116-B
Double Metal Clear
pre -altered for above
5
Window Front
(N)
20
0.99 116-A 0.74 116-8
0
90 Existing Single Non Metal Clear
Existing Zone
1Q
1
12
W__indow Front
Existing
Window Front
(N)
(N)
11.0
11.0
0.32 NFRC 0.27 NFRC
0.790 116-A 0_70 116-B
0.320 NFRC 0_27 NFRC
0
0
90 Altered Milgard double hung
Double Metal Clear
90 Altered Milgard double hung
Existing Zone
pre -altered for above
Existing Zone
13
Existing
x_7 -90116-A_ Z0 116_B
Double Metal Clear
pre -altered for above
14
15
Window Left
Existing
(E)
16.9
0.330 NFRC 0.21 NFRC
0.790 116-A 0.70 116-B
90
90 Altered Milgard French Door
Double Metal Clear
Existing Zone
pre -altered for above
16
Window Left
(E)
50.0
0.990 116-A 0_74 116-B
90
90 Existing Single Non Metal Clear
Existing Zone
17
Window Left
(E)
16.9
0.330 NFRC 0.21 NFRC.
90
90 Altered Milgard French Door
Existing Zone
18
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
19
Window Left
(E)
20
0.30 NFRC 0.30 NFRC
90
90 Altered Milgard Fixed
Existing Zpne
1. Indicate source either from NFRC or Table 11 EA. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING Window OverhangLeft Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len.
Right Fin
Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
3
Bug Screen
0.76
5
Bug Screen
0.76
7
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
12
Bug Screen
0.76
14
0.76
Bug Screen
16
0.76
Bug Screen
17
Bug Screen
0.76
19
0.76
Bug Screen
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Tvoe Length R -Val. Location JA IV Reference Status Comments
Run Initiation Time: 11/07/07 11:13:13 Run Code: 1194462793
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:4 of 13
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Daniel Jones addition 11/7/2007
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments
ZQ
Fxisting
0.76
_0_9.9116=A._0-74 116
Single-RoaMeiaLClear
ate-alteredlo7 above
21
Window Rear
(S)
3.0 0.330 NFRC 0_26 NFRC
180
90 New Milgard awning
Existing Zone
22
Window Rear
(S)
20.0 0.330 NFRC 0.21 NFRC
180
90 Altered Milgard French Door
Existing Zone
23
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
24
Window Rear
(S)
11.0 0.330 NFRC 0.21 NFRC
180
90 Altered Milgard French Door
Existing Zone
25
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
are -altered for above
26
Window Rear
(S)
4.5 0.330 NFRC0 26 NFRC
180
90 Altered Milgard awning
Existing Zone
27
Existing
0.790 116-A 0.70 116-B
Double Metal Clear
pre -altered for above
28
Window Rear
(S)
13.3 0.330 NFRC0 21 NFRC
180
90Altered Milgard French Door
Existing Zone
?,Q
Existing
0_790 116-A 0_70 116-B
Double Metal Clear
ore -altered for above
30
Window Rear
(S)
27.0 0.330 NFRC 0.21 NFRC
180
90 Altered Milgard French Door
Existing Zone
31
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
,U
33
Window Rear�
_Existing
13.3 0.330 NFRC x_21 NFRC _180 90 Altered Milgard French Door
0.790 116-A 0_70 116-B Double Metal Clear
-Exisbng_Zone
pre -altered for above
34
Window Rear
(S)
23.7 0.330 NFRC 0.21 NFRC
180
90 Altered Milgard French Door
Existing Zone
35
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
36
_Existing
Window Rear
(S)
40.5 0.330 NFRC 0.21 NFRC:
180
90 Altered Milgard French Door
Existing Zone
37
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
38
Window Rear
(S)
23.7 0.330 NFRC0 21 NFRC
180
90Altered Milgard French Door
Existing Zone
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len.
Right Fin
Hgt. Dist. Len. Hgt.
21
22
Bug Screen
Bug Screen
0.76
0.76
24 Bug Screen 0.76
26 Bug Screen 0.76
28 Bug Screen 0.76
30 Bug Screen 0.76
32 Bug Screen 0.76
34 Bug
Screen
0.76
36 Bug
Screen
0.76
38 Bug
Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Tvoe Lenqth R -Val. Location JA IV Reference Status Comments
Run Initiation Time: 11/07/07 11:13:13 Run Code: 1194462793
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:5 of 13
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Daniel Jones addition 11/7/2007
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Tvge Area U -Factor' SHGCz Azm. Tilt Stat. Glazing TVDe Comments
3RQ
FxictLg
079 116 -A -O -U 116
Doub_le_M .tal .lew
ore-alteredf9LaboyP
40
Window Rear (S)
33.7 0.330 NFRC 0.21 NFRC
180 90 Altered Milgard French Door
Existing Zone
41
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
pre -altered for above
42
Window Right (W)
14.0 0.330 NFRC 0_26 NFRC
270 90 Altered Milgard casement
Existing Zone
43
Existing
0.790 116-A 0_70 116-B
Double Metal Clear
ore -altered for above
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
40 Bug Screen 0.76
42 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
Run Initiation Time: 11/07/07 11:13:13 Run Code: 1194462793
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:6 of 13
PERIMETER LOSSES
Condition
Insulation
Location/
Type Length R -Val.
Location
JA IV Reference Status
Comments
Run Initiation Time: 11/07/07 11:13:13 Run Code: 1194462793
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:6 of 13
Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R
Daniel Jones addition 11/7/2007
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated Tank Energy Tank Insul.
Water Heater # in Input Cap. Condition Factor Standby R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length_ Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Stephen Ni
Title/Firm: Stephen Nieto Title/Firm: South Wes
Address: 78-120 Calle Estado uite 206 Address: 78120 Call
Telephone: 760-564-4707 f rN Lic. #: 1. Telephone:
(signature) !r / v / / (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Daniel Jones addition 11/7/2007
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
)ased on the adequacy of the special justification and documentation submitted.
Plan I Field
I Multiple Dwellina Units are served by a common water heater. Verifv DHW details on Part 3 of the CF -1 R. I I I
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a
HERS provider using approved testing and/or verification methods. Plan Field
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page:B of 13
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
❑
❑
*§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
*§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
❑
❑
❑
*§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
❑
❑
❑
1. Masonry and factory -built fireplaces have:
❑
E
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
b. outside air intake with damper and control, flue damper and control
❑
❑
❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
❑
❑
❑
§ 116: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑
❑
CF -6R Form:
❑
❑
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑X
❑
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
E
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 1506.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number:
Page:9 of 13
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
❑ ❑ ❑
Lighting Measures
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑
❑
❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑ ❑
R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ 0 ❑
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
❑ ❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
tape shall be used.
❑ ❑ ❑
by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
❑
❑
❑
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support
❑ ❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680
platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions
§ 150(k)7: Lighting for parking lots for 6 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
in the cross-sectional area of the ducts.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
❑
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
❑
❑
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
❑
❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
❑
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑
❑
❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑
❑
❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑
❑
❑
b. Cover for outdoor pools or outdoor spas.
❑
❑
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑
❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑
❑
❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ❑ ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric
and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ 0 ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ ❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
❑ ❑ ❑
by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 6 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number:
Page: 10 of 13
Residential Kitchen Lighting Worksheet WS -5R
Daniel Jones addition 11/7/2007
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
1 57w Com act Fluorescent Tri /Quad 4 in Yes X No F 62.0 x 7 = 434 or
PS5w Lng Cmpt T5 Fluorescent Twin Elec Yes X No 109.0 x 1 = 109 or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
YesNo x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 543 B: 0
COMPLIES IF A,,-- B YES R NOEI
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Paae:11 of 13 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
Daniel Jones addition
11/7/2007
SYSTEM NAME
FLOOR AREA
Res HVAC
2,225
Number of Systems
COIL HTG. PEAK
Heating System
Output per System
Latent
Total Output (Btuh)
Sensible
Output (Btuh/sgft)
Cooling System
Output per System
0
Total Output (Btuh)
0
Total Output (Tons)
0
Total Output (Btuh/sqft)
0
Total Output (sgft/Ton)
0
Air System
CFM per System
5,4501
Airflow (cfm)
Airflow (cfm/sqft)
Airflow (cfm/Ton)
Outside Air (%)
Outside Air (cfm/sgft)
Note: values above given at ARI conditions
26.0 of
—> 4
Outside Air
0 cfm
70.0 of
PSYCHROMETRICS
—Oma
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
I CFM
Sensible
1,252
30,636
2,507
660
28,091
0
5,450
3,604
0
0
0
0
0
0
0
0
0
5,4501
3,604
41,5 1 35,300
Total Adjusted System Output
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
rstream Temoeratures at Time of Heatina Peak)
110 0 OF
Heating Coil
0..4. .... A;. rl-4.
Supply Air Ducts
110.0 of
ROOMS
70.0 of
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolie Peak
111.0 / 77.6 of 78.0 62.3 of 55.0 / 53.7 of
Supply Air Ducts
Outside Air
0 cfm Cooling Coil 55.0 / 53.7 of
41.2% R.H. ROOMS
78.0/62.2 of 78.0/62.2OF
Return Air Ducts
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page: 12 of 13
ROOM LOAD SUMMARY
PROJECT NAME
Daniel Jones addition
DATE
11/7/2007
SYSTEM NAME
Res HVAC
FLOOR AREA
2,225
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Existing Zone
All Existing Rooms
1
1,252
30,636
2 507
1,252
30,636
2,507
660
28,091
PAGE TOTAL 1 1,252 30,636 2,507 660 28,091
TOTAL 1,252 30,636 F 2,507 660 28,091
EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: Page: 13 of 13