Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-5437 (SFD) Title 24
I TITLE 24 REPORT I Title 24 Report LATROBE RESIDE 52845 LATROE LA QUINTA, C CITY OF LA QUINTA foyJILDING & SAFETY DEPT. NC' 'APPROVED ONE SDA / /� BNSTY Project Designer: DAVID YORK, ARCHITECT 12 W. AVE. SAN GABRIEL SAN CLEMENTE, CA 92672 (949.)887=8034 Report Prepared By: DAVID YORK David York, Architect 12 West Ave. San Gabriel San Clemente, CA 92672 (949) 887-8034 %i Pew N. Job Number: _ y EXP.ii°8 0 \\ LATROBE F GN Date: • /llllllll�� 3/2/2006 4.2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance rep�or, This authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Build°ltlg.Efi6q- This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by. EnergySoft �„w,,' Job Number. LATROBE User Number. 3715 I T - TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory' Measures Summary. 9 Form WS -5R Residential Kitchen Lighting 11 HVAC System Heating and Cooling .Loads Summary 12 EnergyPro 4.0 by EnergySoft Job Number.' LATROBE User Number. 3715 Certificate Of Compliance: Residential ft2 (Part 1 of 3) CF -1 R REE.SIDENCE I AT - R ft2 Raised Floor Area: 0 3/2/200-6 Project Title 5,022 ft2 Average Ceiling Height: Date 52845 1 ATROBE LA QUINTA 1.00 Number of Stories: Project Address Building Permit # York_ Architect (949) 887-8034 _David Documentation Author Telephone Plan Check/Date FnergVPrn Compfffice Method 15 Climate Zone Field Check/Date Source Energy Use . Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.37 2.52 -0.14 Space Cooling 64.23 47.26 16.97 Not Valid for permit Fans 9.25 10.59 -1.34 Domestic Hot water 5.11 8.05 -2.94 applications submitted on or Pumps 0.00 0.15 -0.15 after 01/23/06 because Totals 80.97 68.57 12.40 Energy Budget is based on Building Type: &] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (West) 270 deg Natural Gas Area: 1,074 ft 2 Avg. U: 0.46 Ratio: 21.4% Avg. SHGC: 0.34 Total Conditioned Floor Area: 5,022 ft2 Existing Floor Area: nla ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,022 ft2 Average Ceiling Height: 12.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area �JRCDND.LTJONING ----U22 -60,264 1 nn_ Conditioned -Setback- -2 -nla OPAQUE SURFACES Insulation Act. 1st Flnnr Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wood- 535_ -0.069_ -R-21 R-0 0 _270__90 1st Floor Wall -W- od-1.764 _0.06.9 R-21 R-0-0 0- 9.0 Door None 24 0.500 None R-0.0 0 90 Wall_ Wood_ -I3.0_ -0.069_ R-21 _M-0- -90 -90 Mali_ Wood- 2 082 _0..069 -e=21 R-nrm _180__90 Jst-Eloor Roof 1Nnnd 4 550 0.025 _B_3$_ R-0.0 270 Q Roof_ Waod- 472 -0.036_ _R-3.0_ _R-0.0_ -0 0 Gains Condition Y / N Status JA IV Reference Location / Comments New _09--A6 1st Flnnr New 09-A6 1stFlaor New 28-A4 1st Floor New D9 -A6 1stFloor New _09-A6 1stFlnnr New 91-A18 1sf Eloor New D2- Q Jst-Eloor EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Pane:3 of 12 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R LATROBE RESIDENCE 3/2/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 Miadow Front (West) 1.0 0- 0 310 -NEB.. 0.33 _NFRC _227-0_ 90 New JELQU_UFN FIXED AsLFloor Type Length 2 Window Front (West) 30.0 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor None No Insulation 26-A1 3 Window Front (West) 60.0 0.350 NFRC 0_25 NFRC 270 90 New JELD-WEN FRENCH 1st Floor 4 Window Front (West) 48.0 0.790 116-A 0_70 116-8 270 90 New Double Metal Clear 1st Floor 5 Window Front (West) 25.0 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 6 Window Left (North) 24.0 0.350 NFRC 0_25 NFRC 0 90 New JELD-WEN FRENCH 1st Floor 7 Window Left (North) 25.0 0.350 NFRC 0.29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 8 Window Left' North) 40.0 0.350 NFRC 0.25 NFRC 0 90 New JELD-WEN FRENCH 1st Floor 5 Window Left (North) 10.0 0.310 NFRC 0.33 NFRC 0 90 New JELD-WEN FIXED 1st Floor 10 Window Left (North) 10.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 11 Window Left (North) 10.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 12 Window Left (North) 15.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor n Wjndow Left (North) 15-0 0.35.0 -NE Q29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 14 Window Left North) 18.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 15 Window Left (North) 10.0 0.310 NFRC 0_33 NFRC 0 90 New JELD-WEN FIXED 1st Floor 16 Window Left (North) 40.0 0.350 NFRC 0_25 NFRC 0 90 New JELD-WEN FRENCH 1st Floor 17 Window Left (North) 18.0 0.350 NFRC 0_29 NERC 0 90 New JELD-WEN OPENABLE 1st Floor 18 Window Left (North) 27.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 19 Window Left (North) 25.0 0.350 NFRC 0.29 NFRC 0�9 New JELD-WEN OPENABLE 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 3.0 5.0 8.0 0.1 8.0 8.0 0.1 4.0 0 0.1 4.0 0 2 Bug Screen 0.76 3 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 0.0 0.0 0 0.1 4.0 0 4 Bug Screen 0.76 5.0 --&0 0. 8.0 8.0 0. 4.0 _0. 4.0 0 5 Bug Screen 0.76 6 Bug Screen 0.76 8.0 3.0 2.0 0,_1 2.0 2.0 0.1 2.0 0 0.1 2.0 0 7 Bug Screen 0.76 8 Bug Screen 0.76 . 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 600 None No Insulation 26-A1 New 1st Floor Slab Perimeter 400 None No Insulation 26-A1 New 1st Floor Run Initiation Time: 03/02/06 10:04:07 Run Code: 1141322647 EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Page:4 of 12 Certificate Of Compliance: -Residential (Part 2 of 3) CF -1 R LATROBE RESIDENCE 3/2/2006 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGC2 True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 20 -Window -Rear --(East) --71-0- 21 Window Rear East 28.0 -0620-NERC _0..40 _NERC 0.310 NFRC 0_33 NFRC -90 90 _90_ N.ewr F -EED1V0 BOOR est Floor 90 New JELD-WEN FIXED 1st Floor 22 Window Rear (East) 193.0 0.620 NFRC 0_40 NFRC 90 90 New FLEETWOOD DOOR 1st Floor 23 Window Rear (East) 27.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor 24 Window Rear (East) 96.0 0.620 NFRC 0_40 NFRC 90 90 New FLEETWOOD DOOR 1st Floor 25 Window Rear (East) 4.5 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor .25 27 Window Right (South)_ 22.5 Window Right (South) 10.0 0.35U NFRC_ 22 NFRC 0.350 NFRC 0.29 NFRC _1aO_ 180 20 New - JELD-WEN OPENABLE 90 New JELD-WEN OPENABLE 1st Floor 1st Floor 2$ Window Right (South) 15.0, 0.350 NFRC Q9 _NFRC_ 1$9_ -90 New JELD-WEN OPENABLE 1st Floor .29 Window Right (South) 15.0 0.350 NFRC-"2 NERC 180 -90 New JELD-WEN OPENABLE 1st Floor _3Q Window Right (South) 7.5 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 31 Window Right (South). 7.5 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor ,U Window Right (South) 40.0 0.350 NFRC 0.25 -NERC 1fl0_ 20 N-ew JELD-WEN- RENCH tat Floor 33 Window Right (South) 7.5 0.310 NFRC 0_33 NFRC 180 90 New JELD-WEN FIXED 1st Floor 34 Window Right (South) 7.5 0.310 NFRC 0_33 NFRC 180 90 New JELD-WEN FIXED 1st Floor 35 Window Right (South) 7.5 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 36 Window Right (South) 7.5 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 37 Window Right (South) 12.0 0.310 NFRC 0_33 NFRC 180 90 New JELD-WEN FIXED 1st Floor ,3Q Window Right (Soutb) 4.5 0.359 NFRC_0.29 _NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. , Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 16.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.1 4.0 0 23 Bug Screen 0.76 4.0 6.0 2.0 --0-1 ---2-0 _2.0 0. 2. 0 0. 0_Q 0 24 Bug Screen 0.76 8.0 10.0 4.0 0.1 4.0 4.0 25 Bug Screen 0.76 26 Bug Screen 0.76 4.0 5.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.0 0.0 0 27 Bug Screen 0.76 8.0 4.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.1 4.0 0 28 Bug Screen 0.76 29 Bug Screen 0.76 3.0 2.0 10.0 0.1 10.0 10.0 0.0 0.0 0 0.1 4.0 0 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 . Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type f Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 03/02/06 10:04:07 Run Code: 1141322647 EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number: LATROBE Page:5 of 12 Certificate Of-Comaliance : Residential (Part 2 of 3) CF -1 R LATROBE RESIDENCE 3/2/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments -39 JNindow Right (-$outh)__l0_0 _0-35-0 BERG 0-2911FRG 18t __90_ New JELQW.EWORENABI E__ Ast- oor 40 Window Right (South) 10.0 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 41 Window Right (South) 4.5 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist Len Hgt Dist Len Hgt 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 03102106 10:04:07 Run Code: 1141322647 EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Page•6 of 12 e Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R LATROBE RESIDENCE 3/2/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type AIRCONDITIONING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? AIRCONDITIONING Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE (%) Ext. A 0 Smith Water Products CTG -50- Small Gas Recirc/Temp 2 37,000 50 New 0.62 n/a n/a -22 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft)_ Add 1/2" Control # HP Twe In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: DAVID YORK, ARCHITECT Address: 12 W. AVE. SAN GABRIEL Documentation Author Name: DAVID YORK Title/Firm: David York, Architect Address: 12 West Ave. San Gabriel SAN CLEMENTE, CA 92672 San Clemente, CA 92672 Telephone: _(949)887-8034 Telephone:9( 49) 887-8034 Lic. #: `a_.-- g o, o �,D (signature) (date) n e)����`3 (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Certificate Of Compliance: Residential (Addendum) CF -1 R LATROBE RESIDENCE 3/2/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the [aequacy or Me special iusurrca[ion ano aocumentauon sunminea. Plan Field Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10. The HVAC System "AIRCONDITIONING" includes credit for Reduced Fan Power. Fan is shown in the HERS section below. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HERS Required Verification Items In this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -411 pian Field installation certificate. The HVAC System "AIRCONDITIONING" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System "AIRCONDITIONING" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "AIRCONDITIONING" incorporates a HERS verified Refrigerant Charge test or a HERS verged Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System "YORK P1 DUB16V/CZB04211" includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. This building has tight construction with reduced infiltration and a target blower door test range between 1973 and 6444 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 1973 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Paae:8 of 12 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check N/A If not Q ❑ ENFORCE - applicable. NIA DESIGNER MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ FX] ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value:. Q ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls), ❑X ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. Q ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑X ❑ ❑ § 150(f): Air retarding wrap installed to comply with 9151 meets requirements specified in the ACM Residential Manual. ❑X ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X ❑ ❑ perneance rate no greater than 2.0 pemVnch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El 0 El Form: ❑X ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 0 ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑X ❑ S. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, 0 ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑X ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑X ❑ ❑ EnergyPro4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Page:9 of 12 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retumair ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ Q ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑X ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ Q ❑ luminaire has factory installed HID ballast 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,ggarages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR ❑ ❑X ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the Q ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section I I9(d). 7. Flexible ducts cannot have porous inner cores. © ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ Q ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ © ❑ b. Cover for outdoor pools or outdoor spas. 0 ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ Q ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Nonelectrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑X ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,ggarages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR ❑ ❑X ❑ are controlled by an occupant sensor that complies with Section f19(d) that does not tum on automatically or have an always on option. 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ElX ❑ El certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the Q ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section I I9(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. 0 ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro4.0 by EnergySoft User Number. 3715 Job Number. LATROBE Page:10 of 12 Residential Kitchen Lighting Worksheet WS -5R LATROBE RESIDENCE 3/2/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined In Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be Installed In kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 32w Com act Fluorescent Triple 4 Pin Yes _X1 No F 38.0 x 7 = 266 or WIRow Voltage Halogen Yes No IX 80.0 x 3 = or 240 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes' No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 266 B: 240 COMPLIES IF A z B YESC JX NO ❑ EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number: LATROBE Pane: 11 of 12