Loading...
07-1636 (AC)P.O. BOX 1504 78-495 CALLE, TAMPICO LA QUINTA, CALIFORNIA ;92253 Application Number: 07-0000163'6 Property Address: 46300 DUNE PALMS RD APN: 649-040-0.13- . - - Application description: ADDITION - COMMERCIAL Property Zoning: MEDIUM DENSITY RES Application valuation: 6118 Ii• M'dRe I Applicant: Architect -,or Engineer: LICENSED CONTRACTOWS. DECLARATION BUILDING & SAFETY DEPARTMENT .BUILDING PERMIT I hereby affirm under penalty of perjury that 1 am licensed under provisions of. Chapter 9 (commencing with Section 7000) of Division3_of'tlie Business and'Professionals Code,. and my License is in full force;and..effect. License Cle c B' C9 C53 License N_ o.i 435033 Date: _ Contractor: OWNER -BUIL EIi DECLARATION I'hereby,affirm under penalty of perjurythat1am exempt from the Corrtracior's State. License Law for the following reason:(Sec. 7031:5,.Business and Profession& Code: Any city or countythavrequires,a permitto. construct,. alter„improve, demolish, -.or repairany structure,.prior to its issuance,�slso requires,the applicant for the, permit to file a signed statement that he or she is licensed pursuant to the:provisions of the:Contractor's State License Law (Chapter9 (commencing with Section 70 00) of Division 3 of the. Business and Professions,Code) or that he or she is exempt therefrom and'the basis for the alleged exemption. Any+'violationof'Sebtion 7031.5 by any applicant for a:parmitsubjects the applicant'to,.a civil,penalty of not.more than five hundred dollars (6500)•: (__ 1 I, as owner'ofthe property, or my employees with wages as:theirsole compensation, will do,the work, and the structure isnot intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law:does:not apply to.an owner of property who builds-orimproves thereon, and who does the woI k himself or herself through his or her own employees; provided that the improvements are not intended or offered for sale. If, however, the building or improvementis sold within one year of completion, the owner -builder will have the burden 'of proving that hwor she did not build or improve -for the purpose of sale:): (_ 1 Ij as;owne_r of ,the propertyaam exclusively contracting with, licensed' contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'` State L.icense;Lew,does nat.apply town ownerof” property who builds•or improves thereon, and' who. contracts for'the projects with a.contractor(s) licensed. pursuant;to the Contractors' State License Law:). (_) I am' exempt.under'Sec.. „B:&P.C. for thi,s'reason Date:, Owner: CONSTRUCTION LENDING.AGENCY Thereby affirm under penalty of perjury that there is a construction lending agency for the.performance.of the work for which this permit isissued (Seo. 3097, Civ. C.). Lender's Name: _ Lender's Address: LOPERMIT VOICE (760) 777-70,12 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/19/07 Owner: LA .QUINTA CONG_REGATItJ HOVAH P 0 BOX 256 ILA QUINTA, CA 92253 d Contractor: 19" STOKER CONSTRU.C. , 564.71 TWENTYNINE:P YUCCA VALLEY, CA 92284 (760)365-8691 LiC. No.: 435033 \ WORKER'S COMPENSATION DECLARATION .I hereby affirm under,penalty of perjury; one of the following declarations: _ I' have";and: will maintain a certificate".of'consent to'self-Insure for workers' compensation, as provided for •by Section3700mf the Labor Code, for the,performance of the work for which this permit is issued. _ I have and.will:maimain workers! compensation insurance; as required by Section 3700 of the:.Labor Code; for the performance of the,work for which this permit'is issued., My workers' compensation,_ insurance carrier and policy number are: Carrier NIC INS Policy Number 75:600005307 I certify that;, in the performance of the work for which this permit is issued, I shall riot empioy any personlin any manner so'es to become subjectto the workers' compensation laws of California, and.agree that if l,should become subject to the workers' compensatlon. provisions of Section 3 00 of the Labor'Code, trail forthwith.comply with rhos prov ions. Date. Applicant: WARNI Gi FAILURE TO SECURE_WORKERS' COMPENSA ON COVERAGE IS_UNLAWFUL,;AND SHALL SUBJECT- AN EMPLOYER TO CRIMINAL PENALTIESAND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (9100;000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES.AS PROVIDED,:FOR.IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND.ATTORNEWS FEES:. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is:hereby made to the Director of Building and`Safety for a permit:subjectto the ,conditions and restrictions set forth on this application. 1. Each person upon'whose behalf this application is .made, each person et whose request and for fit whose benework is performed under or pursuantto any permit issued as -a result of this application, the.owner; and the applicant,; each agrees to, andshall defend,: indemnify'and hold harmless the City of,,La Quinta, its officers, agents, and employees for any act or omission relatedlto the work being_ performed;under<or'following.issuance;of this permit. 2. Any permit issued es a result of this application becomes null•and void if work is not -commenced within 180 days from date of issuance of such, permit, or cessation of work for 180 days will su6iect permit to cancellation. I certifythat I have read this application and'state•that therabove information is:correct. I agree to comply with all city and county ordinances and state lews'relating to building construction,+and" hereby authorize representatives of this coup Totriter upon the above-mentioned propertyfor i pection'purpos i Date! Signature (Applicant: or Agent): Application Number . . . . 07-00001636 Structure Information Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . ASSY BLDG <300 NO STAGE Other struct info . . . . . CODE EDITION 2001/2005 FIRE SPRINKLERS YES PATIO SQ FTG 460:00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 90.00 Plan Check Fee 58.50 Issue Date . . . . Valuation . . . . 6118 Expiration Date .. . 5/17/08 Qty Unit Charge Per Extension BASE FEE 45.00 5.00 9.0000 THOU BLDG 2,001-25,000 45.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 24..20 Plan Check Fee 6.05 Issue -Date Valuation 0. Expiration Date . . 5/17/08 Qty Unit. Charge Per Extension BASE FEE 15.00 460.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.20 ------------------------------------------------------------------------------ Special Notes and.Comments 460 SQ. FT. PATIO ADDITION Fee summary Charged Paid Credited - -- ----------- ---------- -Permit Due ---------- ---------------.-- ---- PermitFee Total - 114.20 .00 .00 114.20 Plan Check Total 64.55 .00 .00 64.55 Grand Total 178.75 .00 .00 178.75 LQYERMIT Taff 4 4 Q" P.O. Box 1504 78-495 C.ALLE TAMPICO LA QUINTA, CALIFORNIA 922.53 To: Greg Butler, Building & Safety Manager From: Doug Evans, Director -CDD Permit #: 07-1-636 BUILDWO & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-70.11 To CDD: June 5, 2007 Due Date: June 15, 2007 Status: 1 sr Review Building. Plans Approval (This is an approval to issue'a Building Permit) The Community Development Department has reviewed the Building Plans for the following project: Description:. Address or General Location: Applicant Contact: Porch Addition on (2) Buildings 46-300 Dune Palms Rd.. Jeff Stoker (760)250-1176 The Community Development Department finds that: ...these Building Plans do not require Community Development epartment approval. ....these Building Plans, are approved by the Community Development Department. ❑ ...these. Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. 61. Doug Leans, Director -CDD %/7 /0'7 Date Bin ff City of -La QuInta: ' Buil in f d g 8i Safety Division• P.O. Box i 504, 78-495 Calle Ta"MPICo Permit' _ a % La Qulnta CA 92253 - 760 777-7012 -Building Permit APPOcation. and Tracidn - Sheet : ProjectAdatrss:' 4�30C� l��UaG�oJ►. a +Rp Owner,SNamc: aQ Jit 1►�1►�5 A. P. Numbe : .. pip . 13 Address: 22 Ca W . Legal Description: City, ST,. Zip•'3.w1%i b Al. RU -0 contractor. tie ae�_ S-,p�C.e,,�. Telephone: ')( Address: . gr,�.j ( p p�'w,3 `Project Dcs*don - k1., city, n zip: 9 i IL g Telephone: %(r0 •Z Sb •. I (r . State Lic. # 13 * -65a Ci;y Lie #: , _ Ardi., >�'•• �gn� ' tom. a� .I- • :. • Address: City, ST. Zip: Telephone,.'7- •'sig, S q 6{ iAM Consttudionjrpe: Occupancy: State Lie. #: Project type (circle o New Ad&n Alter Repair Demo Name of ContactPeason:..,� �vyeZtl Sq; Ft.: („� #Stories; # Umts: Telephone # of -contact Personr &&frosted Value dProject: APPLICANT: DO NOT WMM BELOW THIS UNE d. Submittal Req'd Recd TRACKING • �/ PERMIT FEES Plan Sete a Pian Check*nbniitted '( 01 Item ...Amount Structural Cala. Reviertsd, ready r corrections Plan Check Deposit r� Truss Cala. Caned Contact (q 6 Plan .Cheek Balanu. Eacra Caia. rlaas Mciced nP Construction, Flood;plufa plan . Plana.reeabmitted Meehadteal Grading, plan 2!! Rcvlew, ready r ¢orrectio , Electrical Sabeontaetor ust • Caned contact Mumbing Grant Deed Pians piekM up .M.1. H.O.A. Approval �.Planrresubmitted . �l Grading IN HOUSE.- ''' Review, ready for correctionsante Developer Impact Fee . Plannlog Approval Called Contact Person A.U.P. Pub. Wigs. Appr Date ofpermitbsee a School Fees Total PermltFees. BUILDING & SAFETY DEPARTMENT November 1, 2007 Mr. John Hacker JHA Engineering, Incorporated 41921 Beacon Hill,, Suite A Palm Desert, CA 92211 RE",Plan Review Extension Request — 46300 Dune Palms Rd. (Kingdom Hall) Dear Mr. Hacker: I have reviewed your letter received via e-mail on. 10/31/07, requesting a time extension for the Plan'Review of the two porch additions at the above address submitted under Application number 074636. Plan review status: - Original application date: 06/04/07 180 -day expiration date: 12/03/07 25 -day extension date: 12/28/07 Under the provisions of California Building Code Section 10.7.4, your request is hereby granted. Please note that La Quinta does not grant extensions beyond a Code change. Because the Building Code specifies that "no application shall be extended more than once," please be advised that unless a building permit for this project is issued on or before Friday, December 28, 2007, your application will expire automatically, and will need to be submitted anew under the 2007 California Building Standards Code. Greg Butler. Building & Safety Manager P.O. Box 1.504 • LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253 (760) 777-7012 0 FAX (760) 777-7011 City of La Quinta Building and Safety Department 78-495 Calle Tampico La Quinta, Ca. 92253 ENGINEERING, _INC. Caxsti>r V Civdl Eng►aeen & S"y= Attention: Greg Butler. Re: Extension to plan check application Dear Mt. Greg Butler, We would like to ask for an extension to the plan. check application for .Permit No. 1636, which is the. La Quinta Kingdom Hall of Jehovah's Witnesses porch addition. The plan check process began in June and we have. been notified that we need to file an extension before: the 180 day expiration deadline. If you have any questions please feel, free to contact our office at your earliest convenience. Respectfully, John H. Hacker R.C.E. 14614 41921, BEACON HILL • SUITE A • PALM DESERT, CA. 92211 (760) 779-0657 FAX (760) 77:9-5'143 TITLE 24 REPORT Title 24 Report for: Kingdom Hall of Jehovah's Witnesses 46300 Dune Palms La Quinta, CA ZLD&%- #. - Project Designer: 11 Report Prepared By: Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 Job Numb r:CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROV D FOR CONSTRU ION gY Date: 9/17/2007 The EnergyPro computer program has.been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the Califomia Energy Commission for use With both the Residential and' Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by,EnergySoft. Job Number. User Number: 2655 t. �• TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form 0LTG-1-C Certificate of Compliance 3 Form OLTG-2-C Lighting Compliance Summary 5 Form OLTG-3-C Illuminated Area Calculation Worksheet 6 Form LTG -MM Lighting Mandatory Measures 7 EnergyPro 4.3 by EnergySoft Job Number. User Number. 2655 ]PERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C " PROJECT NAME DATE Kingdom !Hall of Jehovah's Witnesses 9/17/2007 PROJECT ADDRESS 46300 Dune Palms La Quinta # PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit DOCUMENTATION AUTHOR TELEPHONE Checked by%Daie Insu-form, Inc. (.760) 779-0657 1 Enforcement Agency Use. GENERAL INFORMATION DATE OF PLANS LIGHTING.ZONE 7OUTDOOR LZ1 LZ2 LZ3 LZ4 FUNCTIOiV TYPE OUTDOOR LIGHTING F—] OUTDOOR SIGNS INDOOR.SIGNS PHASE OF CONSTRUCTION Q NEW CONSTRUCTION FX] ADDITION F-1 ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the outdoor lighting system specifications need to comply with Title 24, Parts 1 and of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCU ENTATION AUTHOR SIGNATURE DATE The Principal Lighting Designer hereby certifies that the pro d tdoor lighting and signs. design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110; 119, 130 through 132, and 146,and 149 of Title 24, Part6. Please Check One: (These sections of the Business and, Professions Code are printed in full in the Nonresidential Manual.) 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that. I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. 0 I affirm that I am eligible under the provisions of Divisiom 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that/ am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING, DESIGNER -NAME SIGNATURE DATE LIC. # LIGHTING COMPLIANCE% FORMS & WORKSHEETS Check box if worksheet`is included ®OLTG-I-C: Certificate. of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of'2 maybe incorporated in schedules on the p Either LT.G-1-C or OLTG-1-C may be used for signs as follows:' 1. Use LTG -1-C if the project consists solely of indoor signs. 2. Use LTG -1-C if:the project consists of indoor lighting, outdoor or indoor signs, but.no other outdoor lighting. ,3. Use OLTG-I-C ifth&project-consists solely of outdoor signs, 4. Use OLTG-I-C if the:project consists of outdoor lighting, outdoor or indoor signs, but no other indoor lighting. ®OLTG-2-C: LIGHTING COMPLIANCE SUMMARY. Applicable parts required for ALL outdoor lighting allowances (Except Signs). MOLTG-3-C: AREA CALCULATIONSWORKSHEET. Applicable parts required for all outdoor area calculations. OOLTG-4-C: SIGN LIGHTING COMPLIANCE. Required'for all internally and externally illuminated signs, for both indoor and outdoor signs. EnergyPro 4.3 by'EnergySoft User Number:. 2655 Job Number: Page:3'of;7 ans. leERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-1-C IP80JECT NAME I DATE om Hall of Jehovah's Witnesses 9/17/2007 Lighting Schedules on Plans Show that Outdoor Licifiting Meets Allowed U-cifiting Power ❑X ❑ Lighting power allowance for general site Illumination on OLTG-2-C Part 1 of 4 Not Applicable ❑ ❑X Lighting power allowance for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4 Not Applicable ❑ a Lighting power allowances for specific applications,, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4 Not Applicable ❑ ❑X Lighting power allowances for vehicle•service station canopies on OLTG-2-C part 4 of 4 Not Applicable ❑ ❑X Sign lighting compliance on OLTG;4-C Not Applicable IMandatory ❑ ❑X Measures on Plans Show that Outdoor Ughting Meets Outdoor Liahting Controls Eguiorrient Installed lighting power has been determined in accordance with Section 130(c)1 Not Applicable ❑ ❑X All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumins per Watt or are controlled by motion sensor per Section 132(a) Not Applicable ❑ ❑X All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances,: canopies, and all outdoor sales: areas meet the Cutoff Requirements of Section 132(b) NotApplicable ❑1 ❑X All permanently Installed:outdoor lighting meets the control requirements of Section 132(c)1 Not Applicable ❑ ❑X .Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements of Section 132(c) Not Applicable MANDATORY AUTOMATIC CONTROLS NOTE TO FIELD CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) AREA CONTROLLED EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page -4 of 7 �WQHMNG COMPLIANCE SUMMARY (Part 1 of 4) OLTG-2-C Hall of Jehovah's 9/17/2007 LIGHTING POWER ALLOWANCES - GENERAL SITE ILLUMINATION - Table 147 -Al Allotted Watts Luminaire Lam !Ballasts Installed Watts A B C D E F G H I J K L M I N 1 0 Lighting Applicatlon Category (Table 147-A) r D m' d ,.o., spa a D_ �° I'o rNa �+� r o o D Wx x n d Fla A' o a e Description v Hn,, m e o$ ?: o o r �m �'3 ° r -r c3 3 0� m m rd 0 3 v s m r C01 1-2) ��. m o m m r cd 3 d n m n v m rZ 3c 3 m� o, H ° xa z m Ext Task 76 0.70 5361 (1) 38w Compact Fluorescent 2D Elec 1 38 1. 37.0 X 14 51 I Total Allotted Watts 536 Total Installed Watts 518 I EnergyPro 4.3 byEnergySoft User Number: 2665 Job Number. Page:5 of 7 1 LLUMINATED AREA CALCULATION WORKSHEET (Part 2 of 5) OLTG-3-C IROJECT NAME DATE all of Jehovah's 9/17/2007 A. Hardscalge Method ii Hardsca a for ddvewa s, site roads, sidewalks, walkways and bikewa s A B List Specific Application,(Table 147-A Length of 25"wide path incorporating as much of he paved area as possible. 765 Checklist Checklist ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one, ighting application,.and the applications are consistent with actuatuse of the areas. ❑ Seaton 147 (c)1 B Method,ii -General illumination areas for site roadway, driveway, sidewalk, walkway; or'6ikOwe includes only those illuminated areas that are.in the bounds of the Application and includes a 25 foot wide area running alon the axis of the ath of travel and much of the aved area as ssibla. B. Buildina Entrances without Canopies A B C Smaller of 18 ft or distance to the edge of the Width of Door plus 3 feet on each side property line Area �sf) (A.x B) 51 15 765 Checklist ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only, one lighting application, and theapplications are consistent with the actual use of the areas. Section 147 (c)1 A - General illumination areas Includes only those illuminated areas,that in the bounds of the Application and.are with.a square pattern around a ❑ luminaire that issix -times.ttie luminaire mounting height, with the luminaire imthe middle of the pattern, less any areas that are within buildings, undercanopies, beyond property lines; or obstiucted,by a signs or other structures: I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:6 of 7 1 ILIGHT-ING MANDATORY MEASURES LTG -MM Kinadom Hall of Jehovah's Witnesses 1 9/17 DESCRIPTION Designer Enforcement §131(d)1 For every floor, tall interiorlighting systems shall be equipped with ai separate automatic control to.shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. F §131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is providedwith a :manual, accessible override switch.in sight oflthe fights. The area of override is not to exceed 5,000 square feet 0 §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipmentshall be certified and installed as directed by the manufacturer. Fvl §1:11 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project arecertified and listed in the Directory. All installed fixtures.shall be. certified. §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures -are tandem wired with two lamp ballasts where required by Standards1ection 132; or all one and three lamp fiuorescentfixtures are Specified with electronic high -frequency ballasts.and are exempt from tandem Wiring requirements. 0 §131(a) Individual Room/Area Controls:_ Each room and.area in this building is equipped, with a separate switch or occupancy sensor device.for each area with floor -to - ceiling walls. FX 0131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250"square feet and that allow for the effective use of'daylightIn the area shall have 50% of the lamps in each daylit area controlled by a separate switch;,. or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. Enetgypm 4.3 by EnergySoft User Number: 2655 Job Number. Page:7 of 7 8 KINGDOM HALL OF JEHOVAH'S WITNESSES consrnocnoxeouns PORCH ADDITION IN 771— ASSESSOR's PARCEL NUMBER:. labor bay Veteran's` _ 4 Thariksgltl Christrnas ` r STREET ADDRESS INDEX KINGDOM HALL OFJEHOVAKSWITNESSES; NTALA _ = BUILDING 1 _ TITLE SHEET A RE -INSPECTION FEE OF $30 WILL BE CHARGED IF THE APPROVED PLANS AND JOB CARD ARE NOT ON TO 1-10 THE SITE FOR A S61f#BRMEUMAP INSPECTION. NO EXCEPTIONSI FRED WARING AN ADEQUATELY SIZED DEBRIS CONTAINER N S REQUIRED ON THE JOB SITE DURING ALL 3 PHASES OF CONSTRUCTION AND MUST BE HIGHWAY 111 EMPTIED AS NECESSARY. FAILURE TO DO SO MAY CAUSE THE CITY TO HAVE THE CONTAINER DUMPED AT THE EXPENSE OF THE OWNER/ CONTRACTOR." TO 1-10 z MILES a o N z NORTH p W SITE TLrcU lS� o� ' GENERAL NOTES: 1. ALL CONSTRUCTION SHALL COMPLY WIW04 . 2001 CALIFORNIA j,� BUILDING, PLUMBING, MECHANICAL, ��(LECTRICAL and 2005 ENERGY CODES and ALL OTHER CODES. 2; ALL 'OR EQUAL' SUBSTITUTIONS MUST BE SUBMITTED TO, and. APPROVED BY THE BUILDING OFFICIAL PRIOK-M-It4STALLATION OF THE ITEM. cl B01LD1 ®& QI{J�j�7-a A P� AFE7�, DE -r FOR Cp rl ® VE® LEGAL DESCRIPTION:. J STR T1pN THE SOUTH HALF OF THE SOUTH 3� ��R 0 660 F ET OF THE NORTHWEST QUARTER OF -TKE-NAR f3 _ SECTIO_ N 29, TOWNSHIP 5 SOUTH, RANGE 7 EAS , I BASE AND MERIDIAN, EXCEPTING THEREFROM THAT PORTION fN�.l DUNE PALMS ROAD. } 'F ASSESSOR's PARCEL NUMBER:. 649-040-01.3 STREET ADDRESS INDEX 46300 DUNE. PALMS ROAD T,01 TITLE SHEET LA QUINTA, CA 92253 T.02 SITE PLAN A.01 FLOOR PLAN = A.02 BUILDING ELEVATIONS SQUARE FOOTAGE A.03 ROOF PLAN BUILDING: 4,576 A.04 CONCRETE / FLATWORK PLAN A.05 DEMO PLAN TOTAL: 4,576 A.06 SECTION E.01 LIGHTING PLAN BUILDING CLASSIFICATION GROUP: A DIVISION: 3 TYPE: V FIRE RESISTANCE: NONE TOTAL OCCUPANTS: 293 n�(��OCrl�n lob OCT 31 2007 IU� TITLE SHEET BUILDING 1 Ro co c C� as J co cu IZ c D 0 0 M' w W rn U o 0 cl) rn O v r Z o w I- U Q 2 cn o cr) 1 O I SITE PLAN NOTES: 1. DRIVEWAY APPROACH REQUIRES A.'SEPERATE PERMIT and INSPECTION FROM THE.. CITY OF LA OUINTA PUBLIC WORKS DEPARTMENT. 2. PROVIDE PARKING SPACES TO COMPLY WITH CBC TABLE 11-6 TOTAL PARKING SPACES= 135 REQUIRED H/C SPACES ='5 PROVIDED H/C SPACES - 5 n SITE PLAN BUILDINGS 1 & 2 C) c 0 o rn L' v N o Lu W cn ol c w z ~ U O= J = U vi )o au- a O J J 0 O = M coqctO V z Y C) c 0 o rn L' v N o Lu W cn ol c s � M �. W-0. r LIBRARY . o- •• ■ Illlr) IIr) Illy) Illy) ,Dr) Illy) Illy) Ilrr) Illy) Illy) �. Pow Illy) Ilir) illlr) Ilir) Illy) Ilir) Illy) Illy) Illy) Illy) Illy) �. ►Illy) Illy) Illy) Illy) Illy) Illy) Illy) Illy) ,���) Illy) Illy) ililr) lily) lily) lily) lur) ,lir) lily) lur) lur) liq) ,Irl ' ' ►li►r) I�lr) lily) I�lr) I�lr) I�lr) Inr) I�lr) I�lr) lin) ►lr) ..:. ililr) lilr)ilr) lily) llilr)ilr) il ly) lily) lily) +i�r) I�lr) lur) ITr) � Ilia) lily) lily) lily) ,ir) lilt) lu1) lily) lily) _ •6 � Il�lr) lily) Ills) Illy) IIr) Ar)_,ur) lily) Illy) Illy) Illy) Illy) IIr) I�lr) ►ilr) Illy) Illy) Illi) +�lr) I�lr) Illy) Illy) uiu) lily) ,ilr) ,ilr) ,ilr) +i►r) ►ilr) ,ilr) ,ilr) ,ilr) _ �. o - ■ cn LIBRARYjcc - - r/ !ijj iii irk r�J irk ark .iii ca ca ■ .. _ .. 0cl to �■ El OFFICE d- 00 EAST ELEVATION (PARKING LOT) I � , = t 1 MACHINE DASH PLASTERED I I COLUMNS TYP. STUCCO , I I I I SOUTH ELEVATION (ENTRANCE') - MACHINE DASH STUCCO NEW: FINISH GRADE FINISH PLASTERED COLUMNS TYP. ELEVATIONS BUILDING 1 Tiii fO z 0 v w v W o W w w F- U C/) c Q U >= co 0 U co O� LL 0- O C J :3 J; Q o 2 M 2 `° O 0 Q Z Y 0 d - q� 0 cn N r7 � i 00 Q Qw 'coc -00 I CV .— I FINISH PLASTERED COLUMNS TYP. ELEVATIONS BUILDING 1 Tiii fO z 0 v w v W o W w w F- U C/) c Q U >= co 0 U co O� LL 0- O C J :3 J; Q o 2 M 2 `° O 0 Q Z Y 0 0 q� 0 cn N O o Q Qw 'coc W C '_------------------------ ROOF PLAN NOTES Y • - I 1. FLAT CONC. ROOF TILE. BY MONIER UFETILE COLOR. I:C.B.O. #2656 z 2. ALL FLASHING and COUNTERFLASHING SHAM BE A MINIMUM 28 GA. ED n CORROSION RESISTANT. ALL GALVANIZED VALLEY FLASHING TO BE W rn MINIMUM 28 GAUGE. Irc 3. ROOF TO MEET REQUIREMENTS FOR CLASS "A' ROOF SYSTEM. Ar CLASS 'A' ROOF ASSEMBLY TO MEET ALL REQUIREMENTS PER CBC: �DO �� �A I � 4. STRUCTURAL OBSERVATION PER UBC 1702 IS REQUIRED. z 5. SPECIAL INSPECTION FOR ALL FIELD WELDING, HIGH STRENGTH BOLTING, 0 PITCH LL#-'� I CONCRETE PLACEMENT WITH to > 2500 psi COMPREHENSIVE STRENGTH. F- Jv 6. ALL SHOP WELDING SHALL BE DONE BY A FABRICATOR APPROVED BY Z DEPARTMENT OF BUILDING. & SAFETY PER UBC 1701.7(f). IN LIEU OF.-_ tr FABRICATOR APPROVAL, THE OWNER MAY EMPLOY A SPECIAL INSPECTOR, Q WHICH IS TO BE APPROVED BY THE DEPARTMENT OF BUILDING do SAFETY: LL LLJ I WHO WILL INSPECT ALL PHASES OF SHOW WELDING DURING TIME THE WELDING IS TAKING PLACE. THE FABRICATOR OR SPECIAL INSPECTOR Q Q' B SHALL SUBMIT THEIR CREDENTIALS FOR REVIEW AND APPROVAL BY THE DEPARTMENT OF BUILDING & SAFETY AND PRIOR TO THE START OF Q O I # I FABRICATION OR INSPECTION. i.- 4:12 4:12 4:12 I GENERAL NOTES Z ap I 4 PITCH PITCH DI I• PITCH 4 in 12 Q a to SHEATHING 5/8' Plywood NAILING 6' O.C. ® Edges 12' O.C. O Field ATTIC VENTS Attic ventilation opening shall be covered (n w/ corrosion resistant metalmesh w/mesh W openings of 1/4' in dimension per Sec.1505.3 (n Attic area ® building - 4,576 sq.fL Cl) e 4,576/300 - 15.25 sq.fL attic vents- required Provide min. 15.25 sq.fL attic vents tiles. ®roof: Z Q AREA OF EACH VENT — 2.00 SO. FT. ~ V 8 VENTS PROVIDED - 16 SO. FT. 16.00 SO. FT. > 15.25 SO. FT. I IN X L I !n C_ Q C3 v HEAVY GAUGE ° GALVANIZED STEEL PAINTED TO MATCH O = J 1 ROOF TILES 4:12 '� 4:12 I LU E 4 PITCH PITCH D RECESSED LOUVERED vat$ a CuLL 4:12 N PITCH Q`Q O 1/4-.12 e �# CMO fi x 14 It rL—.r--] sr r r a.• r 0 Ir >o• r Z BUILT-UP FLAT ROOFING 4 4:12 I ROOF VENT DETAIL Y L 1 PITCH 1/4:12 rn I \/ — O O 9 CO O 6'B . 8" IN 40 COL. ROOF PLAN ` Q EMBED. 3'-8' INTO FTG. (3) W/ECC66 WELDED AT TOP — BUILDING 1 U -.1 w W Q = V 0 U) 1w, �ONCREI LATWOR PLAN 3UILDINC= � 5 y r co Cl) cn `° I W I rr-1-0, d I w I U) I W ci I 0 cc WIX E I ) Q a ua a O 0 I C J � CD J 0 -I Q 2 c„ o I � Z I Y REMOVE I _ m EXISTING Q q 0 OVERHANG I rn Lo DEMO PLAN I 1�>Tlolo<l - BUILDING 1 6i w W W o CO N. . 00 cn R' � _rn d 4 Z O Z Q D F 12 m 4' p 16 II 11 II 11 II II II II `��'� NEW PORCH ROOF FRAMING II I1 II IP 11 II II II II IIS Z � Lc) u u u u 11 11 11 11 u 1I a �i�' �, c o� EXISTING TRUSSES - - ECC66 CC614 WELDED AT TOP d w U) 6X14DF#1- 6'X 14DF#1 EXISTING FLOOR SLABLu~ 6' ST SCHED. 40 COL j� 6'0.STL SCHED. 40 COL °1 z EMBED. Y-8' INTO FTG. V U C CURB HT. VARIES Cy (3) 24" DIAM. X 48' FLAGPOLE FTG. N O J W W E PUILPINC4 5�CON A �-. �01 o o Q o o o 01 z Y - C) 4- SECTION 0 0 BUILDING 1 CD o . � a w Q ocni w W, • . i �� f 20 ELECTRICAL NOTES: 1. ALL EXIT SIGNS SHALL BE 6i ILLUMINATYED AT ALL TIMES. TO 0 C INSURE CONTINUED ILLUMINATION 6 ,. FOR A DURATION OF NOT LESS THAN j 1 1/2 HOURS IN CASE OF PRIMARY L c POWER LOSS, THE EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM PROVIDED FROM STORAGE BATTERIES, UNIT EQUIP. OR AN ONSITE GENERATOR. Z 0 �u��. 2. ALUMINUM CONDUCTORS ARE z PERMITTED ONLY IF SIZE 1/0 OR LARGER, and ONLY TO FEED MAIN OR SUB—PANELS. ALL OTHER CURRENT U CARRYING CONDUCTORS SHALL BE COPPER. 3. ALL OUTDOOR RECEPTACLES TO BE WEATHER PROOF and GFCI PROTECTED. _ m 4. ALL WIRING TO BE MC CABLEZ CID o0 0 ccoo SYMBOLS OF EXISTING DUPLEX RECEPTACLE OUTLET QUADRUPLEX RECEPTACLE OUTLET FLOOR DUPLEX RECEPTACLE OUTLET WATT HOUR METER =()WPWEATHERPROOF DUPLEX RECEPTACLE * ALL RECEPTACLES Y8" AFF TO OR 16" TO BOTTOM OF OUTLET BOX (U.O.N.) -mmmL FLUSH MOUNTED PANELBOARD AND LP CABINET (6'-6" AFF TO TOP; U.O.N.) O PROGRAMMABLE THERMOSTAT (5'-0" AFF; U.O.N.) 4 REMOTE TEMPERATURE SENSOR MOTOR � EWCELECTRIC WATER COOLER (EWC) RELAY HOME RUN TO PANEL WITH CIRCUIT NUMBER TS TIME CLOCK FOR EXTERIOR LIGHTS AND EXIT LIGHTS SYMBOLS OF NEW + DECO LIGHTING 0 RECESSED LIGHTING SWITCH HOME RUN TO PANEL WITH CIRCUIT NUMBER LIGHTING PLAN BUILDING 1 Lu w Z F-- Q O Lu OfQ O(L J —i 2. O D Z Y N C a ca J a N C 0 0 M co Ilt rn 0 T- 0 uj w w