Loading...
HomeMy WebLinkAbout07-2966 (BLCK) Wall/Fence__V P.O. BOX 1504 . 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07 -0000296.6 - Property Address: 47795 DUNE PALMS RD APN: 60A-020-0307 -. Application description: WALL/FENCE Property Zoning: REGIONAL COMMERCIAL Application valuation: 62800 Applicant: Architect or.Engineer: LICENSED CONTRACTOR'S DECLARATION BUILDING soot s z t+vr v 1 hereby affirm under penalty of perjury that. ['am licensed under provisions,of 'Chapter,9, (commencing with Section TOGO) of Division r3 of the Business and'Professionals Code; and'.my License.. is in,full-force and effect:. License Class: B Li` No.: 396120 Date: th & Contractor: OWNER=BUILDER: DECLARATION I hereby affirm under penalty of perjury that I.am exempt from the Contractor's.State License Low -for the following reason (Sec: 7031.5,,Business and Professions�Code: Any city or county -that requires a permit to construct, alter, improve, demolish, or repair'anystructure, prior to,its issuance, also requires the.applicant-for'the_ permitsto file a signed statement that;he or she is licensed pursuant -to the provisions of the Contractor's State License Law (Chapter -9 (commencing,with Section 7000) of;Division 3 otthe BusinessandProfessions Code) or that he•or she, is.exempt therefrom and,the basis for the alleged exemption. Any violation of Section 7031 .5.by anyapplicant for a permit subjects the applicant to a civil penalty of'not more.than five hundred dollars ($5001.: 1—) I, as owner of the property;.or my employees with,wages as their sole compensation,, will do the work_, and the structure is not intended or offered for sale, (Sec. 7044, Business and Professions Code: The. Contractors' State License Law does not apply to an owner of property who. builds or improves thereon, and who does.the work himself:orherself through his or he,ownemployees, provided that' -the improvements are,not intended or offered for sale. If, however, the building or improvement is.sold within one year of completion; the owner -builder will 'have the burden of proving that he or she did not build or improve for the purpose of: sale:): I _ 1 l,, as owner of the property, :am exclusively contracting with licensed contractors to construct the project (Sec: 7044, Business and Professions Code: The Contractors' State License Law does not applyto an owner of property who builds or improves thereon, and who contracts for the projects with -.a contractor(s) licensed pursuant to'the Contractors' State License Law.). y _) I am exempt under Sec. , B.&P:C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under -penalty of perjurythat:there,is a..construction lending agency for the performance of the workforwhich this permit is issued ISec. 3097, Civ. C.), Lender's Name: Lender's Address: LQPERMTf VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/16/08 Owner: COACHELLA VALLEY a45701 MONROE ST INDIO, CA 92201 HOUSING COALI 1-G Contractor: BROWN CONSTRUCTION., INC. PO BOX 9.8'07'00 WEST'SARAMENTO, CA 957.98 (916)373-930,0 Lic.. No.: 396120 WORKER'S COMPENSATION' DECLARATION I hereby affirm under penalty of perjury one of the4ollowing'declarations: . I have and will maintain -.a certificate of consent to:se[Mnsure.for workers' compensation,;as,provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. I have and will maintain workers' compensation:insurence, as required by Section,3700,of the Labor Code, for the, performance' of the work for which this permit is issued. My workers' compensation insurance carrier 'and policy number are: Carrier AMER INC Policy.Number 3424:477 _ I certify that, ircthe performance of the work forwhich this permit is,issuad, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California; and agree,that, if I should become .subject .to the workers: compensation provisions,of Section 3700 of!the de�1 a1»4' rthwith cam I w' : hose provisions. Dater Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES,AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000). IN ADDITION TO'THE'COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION3708.OF THELABORCODE; iNTEREST, AND ATTORNEY'S:FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the.Director of:Building and Safety for a permit subject to the conditions and, restrictions set'forth on this application. 1. Each person upon whose behalf this application is,made, each person at whose request and for whose benefit work,is performed under or pursuant,wany..permit issuedas aresult of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless.the City of La Quint&, its officers, agents and employees for anyact or omission related to the work being performed under or following issuance of this permit. 2. Anypermit'issued as result of this application becomes null and void if work isnot commenced within'180 days from date, of,issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. l,certify thatl have read this, applicationandstate that:the above.information.is correct. I agree to comply with all city and county ordinances andlstate laws relating to b4jWieg•eene ion„ewd-p- uthorize.representatives ,of this county to.enter upon the -above mentio ,Inspection ores. Date;-_ %1110olt Signature, (Applicant or Agent)- — - 3 Application Number . . . . . 07-00002966 Permit WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 473.00 Plan Check Fee 00 Issue Date . . Valuation 62.800 Expiration Date 7/14/08 Qty Unit Charge Per Extension BASE FEE 414.50 13.00 4.5000 THOU BLDG 50,001-100,000 58.50 ------------------------------------------------------------------ Special Notes and Comments• PERIMETER+WELL SITE WALLS [ORCO SPEC] WALL HEIGHTS SHALL NOT EXCEED APPROVED SITE DEVELOPMENT REQUIREMENTS. 2001 CBC. THIS PERMIT DOES NOT INCLUDE INTERIOR SITE WALLS, TRASH ENCLOSURES OR MONUMENT SIGNS.• January 9, 2008 9:41:21 AM AORTEGA Fee summary Charged Paid Credited Due ---------- ---------- Permit Fee Total 473.00 .00. ---------- .00 473.00 Plan Check Total .00 .00 00 :00 Grand Total 473.00 .00 .00 473.00 LQMRMIT :i, FEB.-25-2008(NON) 08:26 SOUTHERN CR SOIL 4 TESTIN6 (FAX)760 775 8362 P.013/034 .'" '4N "` SOUTIMR v c�o� s0�. & TEs�Q INC.'55306 6240 RWHROALL STRMT. BAN DIEGO. CA 92120 a Phrm.(019) 2110.4331 Fax (619) 280.4717 1 83-740 CrMUS AYL�NUC, SUITE CA DMIO. CA 922 1 • Phone (760) 775-5993 Fax (760) 775.4362 s1 &T FILE RCL N� C am PL NC FDC wulin l ov _ I . — MW 1NS Wfi0N. MPW FM gmfORM00=m IQWFOMWMMOWV ❑ wa3= ❑ BE ROOK o Q.C. COMMM O ROOMGlWATERPROOFING ❑ P.T. CONCMMISMM ❑ 13.MANCHOM p H.S. WX= ❑ TIMOJFt:I p PNI1S,f: hKLTa► r.. eV. 'iA 06R'RtNQ: rJ C4AAR! WD.f N N .,t_ PA. r... L 'T21 &„carat NJA npamtu: %Ve . a DEAl 4vt r u cUraw ; 1DCJVR7N -s4 17A1E D86CIf M Mt OF WORK MEWMD- MM M M Vft a'S VM ww"m 3acwv'1 .' �. �>r ,f:. O .6.1� y` G At All. qA-01WAZ lam. Gr d f-' Z ' L.G �� � o �► w»�r t , ' .rte �^1 � S iJ IM ►�,. � x � ' W M W u? 414M A49 A'v- le /10-4f !Yf . XS �. UM l h%Mby Certs #131 l'hOM UVPOCM M LOOM POMI d work Urma nQ10!(OIfOC1wft . 111Q mA trapeated 4 to the bed d my M WMOE QO Mn Complla = "llh the MPM*d PkM Oulaalp o11D CppOCado f the goYeirrYtg IOY�a j'�” %'` �'� �� QRS IUIa: RL4GISRLUION HQ USA I hme gf Cesw "Val hoe ' ' F; 4ed Mie Cboyo, wMMOC wont In awcvdm=Th the IOgIlhOh10lH' 01 DSA OppMOWO dOCU(T1onh 8Rnpov antlih�/EhQ WC10 Cormc d In aooOrdonOe Vwlh ft Offt.D%k44mw�w we vak Put �Mlpt1lfe do0urnorlx 'WKA+ewmo�ko�lhorJtrOwwOrk 111MpOfif011NaQlt; NRR-03-2008(.KON) 12:98 SOUTHERN CR 50IL & TESTI'NG (FRx,)760 775 8362 _ _ P.017/020 `°n """'°' "` SOUTHERN CALIFORNIA SOIL & TESTINGS, INC. 55,312 &m,R1VWAU S1'RRfrr, PIAN DISCO. CA 92120 • ftme (619) 2804321 fax (619) 204717 K3-748 CrMU5 AVENUE, • %Url*E 4 1NDIO. CA 92201 . Phone (760) 775.5983 Fax (7(Al) 7754362 SMT PILENM4 $ P.O. NM" C IM I PL I I I NC li I I RX I I rmu r ar FW hiBPECTION REPORT Kft ❑ tIEA1Pp>i w ccwMM - MASOM ❑ WROM ❑ mmomo c,c,coNcRM ❑ M0F1N lWX8WW0VW ❑ Pi CONCEM isl m ❑ e-OWANCM0. .0 "=MG Q NIOJE MM biAte- PWZ#: MFulo. MAW. m! 1A 7 9 wlfl PkilAs & ..VqWo ' CaNIRlK:IUIR !l � �vuomcrt�eciry: � /� acf:of 6. et, �!. DAZE. ONION OP WORK UGPECMD. 7W MONme flmpwslr my Duni it 3SQ V4 Z,7� I !�r or� . A[ S7j'"► �lrhroor 64F Ar 01E s �•�. ! A- f I �R• .� � :� osw+ r,✓ ' AoeZt F,/Z � `. C.i's'� ,,...r...� �' I �_ r fib..•► IDG I h0i0Dy CoAW MW I hoW kq9GW MO abovelow work W" noted alNetgYkeLOFF to work hepWICO Is to 1W (Deaf of ImowloaQC In Corr plWae wllh Ino apprarod elan► VeCMccW,. 9 ��,� lo t�edor curiae I raC6nuu10�I NG DU I hereby cofW W f nw+e hpecled iho dWM rotaorted work In cw rcWw vAM fig Z �$ � ? r regWP rr" of DBA qVrOrod memQen SA d 1o:AInD were 00MLOW in OCC«aa11Co wm 1h_a a"0% vavMld Ifre wat 1DAM corrg3ft w M To dooLDYW eamfarQwf Mmrmrcav vlrx tlspxta hgllae SOIL & TIISTINO, mc. SOUTHERN CALIFORNIA SOIL & TESTINGS INC. 553-06 0 I� 6280 RIVERDALE STREET,' SAN',DIEGO, CA 92120 • Phone (619) 2804321 Fax (619) 2804717 S 83-740 CITRUS AVENUE, • SUITE Q INDIO, CA 92201 • Phone (760) 775-5983 Fax (760) 775-8362 SCS&T FILE NO._ 01220 04? P.O. No.. l C PL NC FIX PAGEOF I FIELD INSPECTION' REPORT FOR: ❑ REINFORCED CONCRETE REINFORCED MASONRY ❑ WELDING ❑ FIREPROOFING Q. C. CONCRETE ❑ ROOFING / WATERPROOFING ❑ P.T. CONCRETE/ STRESS ❑ EPDXY ANCHORS ❑ H.S. BOLTING ❑ PROJECT In nL TD ►n3 7ASE.#: N DFILENO.:J(� DA APP NIA PROJECT ADDRE ' q'779571>4-, t. Pa w,S led. PERMIT NO.: PLAN FILE NO.: NIA ARCHITECT: II �Y• t�va v 2 h ENGINEER: GKenwrl414-q j -A" vX GENERAL CONTRACTOR: f SUB CONTRACTOR: I- 1 Y+t a i _G,, LOCATION OF WORK INSPECTED: C'!4 MATERCLASSIfICAIION IAL : w�D /ry DATE DESCRIPTION OF WORK;INSPECTED: TIME ARRIVED: 97"^" TIME DEPARTED: 3P" G G /0 /+5 o t y= 1/'/S �i °� o :, ,-A f/u Q16., ZGG�� 4 o 0 4,, edv":59- / V Af�ewor/tea l .�,-.c � �-•-r. / s IVa✓ _ ,t' a��c. s � l...r / �E. 4S,' Or / ,LQ'y AVDL -1r j Tfi'. SCr D f �N�?�Y� G���• Lli .S/t-S/ A �oYC r �sq � [t diY/fi G�vyt Qry,/sgarMCy LJi �-� ,� •% S RE. REVIEW: UBC I hereby certify #vat I have Inspected the above reported work. Unless noted otherwise, . the work inspected'is to the best of my knowledge In compliance with.the;approved plaits,, the governing building laws. specifications and applic2F_0'0� (� . Inspector IriHials' INSPE RS SSNATURE REGISTRATION NO. DSA I hereby certify that I have Inspected the above reported work in,accordance wtth the Z� . v� requUements of DSA approved documents. Sampling and testing were conducted In accordance with'the requirements of the DSA approved doc4pafft: The Wolk Inspected PWMINTENDE11111S WjkTURE DATE compiles with the >pog6d documents Yes: hlo• ~Inspector Initlals: SMI zos REV 2)06 l i `°`" *""" "` SOUTHERN CALIFORNIA SOIL & TESTINGS INC. 5 5 3 12- o 6280 RIVERDALE STREET, SAN DIEGO, CA 92120 • Phone (619) 2804321 Fax (619).280-4717 83-740 CITRUS AVENUE; SUITE G, INDIO, CA 92201 • Phone (760) 775-5983 Fax (760) 775-8362 '/ SCS&T FILE NO. T D 0 " P.O. NO. - r'f C M I PL I I NC I F—F1 I I PAGE ( OF i. FIELD INSPECTION REPORT FOR: ❑ REINFORCED CONCRETE j9rREINFORCED MASONRY ❑ WELDING ❑ FIREPROOFING Q. C. CONCRETE ❑ ROOFING /WATERPROOFING ❑ RT. CONCRETE/ STRESS ❑ EPDXY ANCHORS ❑ H.S. BOLTING ❑ PROJECT TITLE: du��S PHASE #: DSA FILE NO.: � DSA APP. NO.: IJ ✓~' n L N�� N PROJECT ADDRESS4-7-7 �� �„ p w t n /) . J d�/VJL/ PERMIT NOi�a _ �� �� �/] PLAN FILE NO.: ARCHITECT: CO ENGINEER: , U1rAG dV r- H!/t/ N 4/.rl�Glam/�t GENERAL CONTRACTOR:SUB ivI,�Y7 ltL. / 0-"/ CONTRACTOR: C7 ' �► / "�fEsC�% LOCATION OF WORK INSPECTED' �4L MATERIAL CLASSIFICATION: 4 400, C / -14XV DATE DESCRIPTION OF WORK INSPECTED: TIME ARRIVED: TIME DEPARTED: a , Z -v7' c 67 l / , AGG •G �j L.7 / tG�l /H G �. / O /� �•� �o ` a i� a-i� wo 010 a o -rk 4 r a ' /� %y , g2• t /,rs r,,- Z/ - Z� Iry aS lirw Lsy► f yw�w.•� l.Z l.Jr -/h- Awn . L RE. REVIEW: 'UDC I hereby certify that I have Inspected the above reported wail Unless noted otherwise, the work Inspected Into the best of mV knowledge in compliance with the approved, plans, specifications and applof the governing building laws: Inspector Initials r% IN S TUBE REGISTRATION NO. DSA I hereby certify that I have Inspected jhe above reported work In,accordance Ilth the _ Z Z-7 requirements of DSA approved documents. Sampling and testing were conducted in accordance WIIII the -fegU Of the,DSA approved doCU IS. 'Thework:inspected PERINTEN SIGNA E DATE compiles With the DSA documents. - •argnuhue wnlorrzes Yes: Inspector lniMais: scsaT aos aEv arae r'f 'SOIL ° """° "` SOUTHERN CALIFORNIA SOIL & TESTINGS INC. '55321 6280 RIVERDALE STREET, SAN DIEGO, CA 92120 •Phone (619) 2804321 Fax (619) 280-4717 83-740 CITRUS AVENUE, SUITE CA INDIO, CA 92201 • Phone,(760) 775-5983 Fax (760) 775-8362 Qy' f SCS&T FILE NO.: 0 o v?'ZO j P.O. NO. - C PL NC FIX PAGE / OF�_ FIELD INSPECTION REPORT FOR: []'REINFORCED CONCRETE REINFORCED MASONRY ElWELDING E]FIREPROOFING Fj Q. C. CONCRETE ❑ ROOFING /WATERPROOFING ❑ P.T. CONCRETE [STRESS ❑ EPDXY ANCHORS ❑ H.S. BOLTING ❑ PROJECT TRLE: PHASE #: N DSA FILE NO.: N r4 DSA APP. NO.: N to W, s ►Q PROJECT ADDRESS / 97 �" �a�I PERMIT NO.: �' w� '' 9I PLAN FILE ^, A N t- � G 0., S if ARCHITECT:. ENGINEER: GENERAL CONTRACTOR: SUB CONTRACTOR: iA A'+ i Pi. /1l• LOCATION OF WORK INSPECTED: MATERIAL CLASSIFICATION:� /y� p►c i� v5-oVIJ1 DATE DESCRIPTION OF WORK INSPECTED: TIME ARRIVED: TIME DEPARTED:S"^4 YC S � " 61 ifr � ra ✓� . GOYI %^ih 0`LI N$. �' Q I i alc G• -r b qypm-p n rsF rf s H S c c/f k✓e�<, Jr A—✓07,-. CG " S A 6 G , so, . R - a�..�► i. Izz, e- �rj r f y e Zoe. 7 /K A L111 -01y hog eo oAv P.E. REVIEW: UBC I hereby certify mat I have Inspected the above reported work. Unless noted otherwise, the work,lnspected Is to the best.of.myknowledge In.compllance wfm the approved plans, speclficatians and applicable ihe.governing building laws. 7 �/ R`► j , Inspector Inma1S INSPECTS SIG T REGISTRATION NO. DSA I hereby certify that'I have Inspected the above reported work In accordance with the Sampling b 0 p y requirements of DSA approved uments and testing ., conducted In accordancem.1th the req nts of the DSA approved docum The work Inspected. •S DAiE complies with the documents Yes: Inspector. Initials: ovl►iorizes rhe abae wak srser zos REV 2106 Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: - "XtY 77-r' TI%tAio Owner's Name:! �{ Address: '16 `961 kAAJ2ftPE 1.97li— /—OW/VW4 A. P. Number: �j ,--p e� ^'� 3 Legal Description: City, ST, Zip: ���/� lt�A41 e Contractor: 73ftX_SXJ Telephone: p 1 43 21 3r.— Project Description: Address: City, ST, Zip: Telephone: City Lic. #: ! IVtM W 1 « Dr ` vI State Lic. # : Arch., Engr., Designer: Address: S. L� � r f 1 City, ST, Zip: /�'f IL/i(,r� •Z•s� Telephone: JLM3 � Construction Type: Occupancy: State Lic. #: p Project type (circle one Add'n Alter Repair Demo Name of Contact Pe son: Sq. FL: # Stories: # Units•. Telephone # of Contact Person r 32 d Estimated Value of Project: APPLICANT: O NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"' Review, ready for correctionsrissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- "" Review, ready for correction ssue Developer Impact Fee Planning Approval Called Contact Person I 1 Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees l °i' 14A)8 ' W*VY TO 7*60C Tibf 4 4 a9ba P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To Planning: November 13, 2007 From: Les Johnson, Director -Planning Due Date: November 26, 2007 Permit #: 7-2966 Status: 1st Review Building Plans Approval (This is an approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: Site Lighting/Perimeter Walls/Signage Address or General Location: 47-795 Dune Palms Road Applicant Contact: Maria Song (760)902-5028 The Planning Department finds that: ❑ ...these Building Plans do not require Planning Department approval. ...these Building Plans are approved by the Planning Department. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please turn them to the Planning Department for review. • I Z S o'7 es Jo n on, Director -Planning bale • Faxi 4 /MAMAIri F S(f��15 ' 6�� t� .sue z r'� '��zx►rt- r�.1 + Aff9cqA4-c"t�� • >e-- APP&ck5t�. -ftvvm o4s ETA Awv=oAL Biz City of La Quinn Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Petmit # 2"I Project Address: — ���Wft<;Owner's Name: s A. P. Number: 1 ' O%),(+ Address: �v r��� C Legal Description: TOMONOr— 05r DNE tiW W 5M City, ST, Zip: N 1) Cjk [ U Contractor: ' l N M 01\1 Telephone: ` ?j Address: I e S • 1�41\40 . Project Description: City, ST, Zip:: W, U I H I V Telephone: —L `2� ' K/ .�26 6 pep WS State Lic. # : 'J City Lic. #:! , Arch., Engr., Designer: (N t N CO Address: S. clvlo w- 4 la City, ST, Zip: Telephone: Construction Type: Occupancy: State Lic. #: C109 Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: tAN A— SON Sq. Ft_: # Stories: # Units: Telephone # of Contact Person: q.01 r;12$ Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Req'd TRACKING PERMIT FEES Plan Sets Plan Check submitted ( 9, Item Amount Structural Coles. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans bicked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN IIOUSE:- 7r' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees �- CITY OF LA QUINTA PLAN CHECK CORRECTION LIST Interactive Design Corporation 199 S. Civic Drive, Suite 10 Palm Springs, CA 92262 (760) 323-4990 PLAN CHECK NO. 07-2966 ADDRESS 47-795 Dune Palms SCOPE OF WORK Lighting Pole FDN's December 19, 2007 FIRST CHECK/FINAL (Structural) OCCUPANCY R-1/U-1 TYPE-OF-CONST. V-N The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Perry stopoulos, PE VCA CODE GROUP 2200 W. Orangewood Avenue, Suite 155 Orange, CA 92868 (714) 363-4700 #756 VCA File No. LQ-20470 1 8' HIGH ORCD WALL SYSTEM SITE WALL • FOR 80 MPH WIND @a EXPOSURE C WALL TYPE 2 W/ INTEGRAL COLOR SLUMPSTONE IJ OPTIONAL FLAT CAP z z moQ� CITY OF LA U I B ILDING & SAF APPROVE ORCO 6616 CMU GROUTED ONLY @ VERT STEEL NOTE: PROVIDE 06 DOWEL AND #4 DROP -IN BAR AT EACH SIDE OF CONTROL JOINT. #4 VERT DROP -IN BAR @ 16' O/C (36' O/C FOR 18' LONG CMU) #6 STD JOINT REINFORCEMENT @ 24' O/C (4 PLACES) PER USC STD. 11-10. USE 45 STD. FOR SLUMP BLOCK #6 DOWEL @ 16' O/C (18- O/C FOR 18-LONG CMU) 8+2'-9' I I I I ( I I I I I #4 HORZ CONT. DESIGN CRITERIA: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF Z. ALLOWABLE LATERAL PASSIVE PRESSURE = 150 PCF 3. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 4. REINFORCING STEEL : GRADE 40 FOR #4 WS AND SMALLER 8 GRADE 60 FOR #5 AND LARGER S. SELSMIIC - ZONE 4, Na = 1.05 6. 1500 PSI MASONRY COMPRESSION STRENGTH, HALF STRESSES USED - NO SPECIAL INSPECTION REQD. MIN. FOOTING DEPTH FOR 5' TO DAYLIGHT SLOPE WALL @ FOP WALL @ 1 FT. SETBACK WALL @ 1 Ff SETBACK 1 7101 2-6^ 2'-0' 3 TO 1 11-8' NOTES.- 1. CONCRETE BLOCK SHALL CONFORM TO UBCSTD. 21-4. ORCD STD. PRECISION, SPLIT FACE SLUMPED, OR WEOGELOCX BLOCK MAY BE USED 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 1-112 PARTS 54ND TO 3-1/1 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE11/V. Fc = 2000 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO AWN A 615 GRADE 40 FOR #4 BARS AND SMALLER, GRADE 60 FOR #5 AND LARGER. PROVIDE 40 54R DIAMETER LAP FOR GRADE 40 REA4R AND 48 BAR DIAMETER LAP FOR GRADE 60. 4. REL34R SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOC4TED. 5. CONCRETE BLOCK SHALL BE LAVED IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO, 6. ALL BLOCK CFLS CONTAINING VERTICAL REHAR SHALL BE SOLID GROUTED. 7. USE OBP TYPE S MORTAR PROPOR77ONED USING UBC TABLE NO. 21-A I PART CEMENT TO 1/1 PART LIME TO 4-1/2 PARTS DAMP, LOOSES4ND. & GROUT FOR CONCRETE BLOCK TO BE 1 PART CEMENT TO 3 PAR75 54ND (GROUT MAY CONTAIN 2 PARTS 3/8' PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSITUENTS 9. BLOCK STEM MAY BE WET -SET 1-1/1' INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC BLOCK STEM MAY BE PLACED TO EITHER EDGE OF 7HE TRENCH TYPE FOOTING, 10. FOOTING MUST' BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPAC71ON OF 90 %. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETEANDALL REQUIRED STEEL IS TILED IN PLACE SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING 40' O/C OR 20' IF THE WALL IS TO BE STUCCO COATED. 5' TO DAYLIGHT I"A COACHELLA VALLEY HOUSING COALITION DUNE PALMS/LA QUINTA /O 4 O u m w m ~ cn C31925 z * Exr.12-31-2008 \s�q� CIV 1\- -NT DATE-1 Timothy S. Mallis - Civil Engineer Title : Job # Dsgnr: Date: 8:31AM, 9 OCT 00 Orco Block Inc. Description 4510 Rutile St. Riverside, Ca. 90509 Scope: (909) 685-1521 Rev: 510300 Cantilevered Retaining Wall Design Page 1 User. -99 E '1 3522, Ver 5..3, 22Jun-1999, W n32 I (c) 1983.99 NERCALC c:\ec\new6walls.ecw:Calculations Description Orco Wall System 8'-0" high tract wall Tor 60 mph Exp t; wlna condition Criteria Retained Height = 0.33 ft Wall height above soil = 7.67 ft Slope Behind Wal = 0.00: 1 Height of Soil over Toe = 4.00 in Soil Density = 110.00 pcf Wind on Stem 16.9 psf Design Summary Total Bearing Load 846 Ibs ...resultant ecc. 9.36 in Soil Data Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 30.0 Toe Active Pressure = 30.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Frictior 0.300 Soil height to ignore for passive pressure 0.00 in Soil Pressure @ Toe 1,199 psf OK Soil Pressure @ Heel 0 psf OK Allowable 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,661 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 8.0 psi OK Footing Shear @ Heel 2.7 psi OK Allowable 76.0 psi Wall Stability Ratios Overturning 1.59 OK Sliding 2.48 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 129.5 Ibs less 100% Passive Force- - 133.3 Ibs less 100% Friction Force= - 253.7 Ibs Added Force Req'd 0.0 Ibs OK ....for 1.5 : 1 Stability 0.0 Ibs OK Footing Design Results Toe Heel Factored Pressure 1,661 0 ps Mu': Upward 772 0 ft Mu' : Downward 165 179 ft Mu: Design 607 179 ft Actual 1-Way Shear = 7.95 2.70 ps Allow 1-Way Shear = 76.03 76.03 ps Toe Reinforcing = None Spedd Heel Reinforcing = None Spedd Key Reinforcing = None Spedd Stem Construction �# i Top Stem Stem OK Design height ft= 2.67 Wall Material Above "Ht" Masonry Thickness 6.00 Rebar Size # 4 Rebar Spacing 32.00 Rebar Placed at Center Design Data fb/FB + fa/Fa 0.712 Total Force @ Section Ibs = 90.1 Moment.... Actual ft-# = 240.1 Moment..... Allowable ft-# = 337.1 Shear..... Actual psi = 4.0 Shear..... Allowable psi = 25.8 Bar Develop ABOVE Ht. in = 20.00 Bar Lap/Hook BELOW Ht. in = 20.00 Wall Weight psf = 47.0 Rebar Depth 'd' in = 2.81 Masonry Data - fm psi= 1,500 Fs psi = 20,000 Solid Grouting No Special Inspection No Modular Ratio'n' 25.78 Short Term Factor 1.333 f Equiv. Solid Thick. in = 3.90 # Masonry Block Type = Normal Weight # Concrete Data fc psi = i Fy psi = i other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S " Fr Heel: Not req'd, Mu < S ' Fr Key: No key defined Footing Strengths & Dimensions 'c = 2,000 psi Fy = 40,000 psi An. As % = 0.0012 roe Width = 1.00 ft feel Width = 1.50 Total Footing Widtt sooting Thickness = 12.00 in Key Width 0.00 in Key Depth 0.00 in Key Distance from Toe 0.00 ft over @ Top = 3.00 in @ Btm.= 3.00 in 2nd Stem OK 0.00 Masonry 6.00 # 6 16.00 Center 0.992 129.6 539.9 544.0 5.4 25.8 30.00 6.00 52.0 2.81 1,500 20,000 No No 25.78 1.333 4.50 4 Timothy S. Mallis - Civil Engineer Orco Block Inc. 4510 Rutile St. Riverside, Ca. 90509 (909) 685-1521 Rev: 510300 User. KW-0603522. Ver 5.1.3, Z2.J -1999, W.32 (c) 1963-99 ENERCALC Title : Dsgnr: Description Scope: Cantilevered Retaining Wall Design Job # Date: 8:31AM, 9 OCT 00 Description Orco Wall System 8'-0" high tract wall for 80 mph Exp C wind condition Page 2 Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 26.5 0.44 11.8 Soil Over Heel = 36.3 2.00 72.6 Toe Active Pressure = -26.7 0.44 11.9 Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 129.6 5.17 669.5 SeismicLoad = Total = 129.5 O.T.M. = 669.4 Resisting/Overturning Ratio = 1.59 Vertical Loads used for Soil Pressure = 845.6 Ibs Vertical component of active pressure used for soil pressure Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load Axial Dead Load on Stem = 0.00 Soil Over Toe = 36.7 0.50 18.3 Surcharge Over Toe = Stem Weight(s) = 389.4 1.25 486.7 Earth @ Stem Transitions = Footing Weigh( = 375.0 1.25 468.7 Key Weight = Vert. Component = 8.3 2.50 20.8 Total = 845.6 Ibs R.M.= 1,067.2 Timothy ;il Engineer Title: Job # Orco Ell- Dsgnr: Date: 8:23AM, 9 OCT 00 t Description 4510 Rutile 5 Riverside, Ca. 90509 Scope (909) 685-1521 Rev: 511Y300-06 Pole Embedment in Soil Page 1 User: KW-aea3522, Ver 5.7.3, 22-Jun•1999, Win32 g * i (c) 1983-99 ENERCALC c:\ec\new6wa11s.ecw:Calcu1ation Description Trench footing for 8'-0" high block wall 80 mph Exp C wind condition General Information Allow Passive 150.00 pcf Applied Loads... Max Passive 1,500.00 psf Point Load 0.00 Ibs Load duration factor 1.333 distance from base 0.000 ft Pole is Rectangular Width f4,4411-az 4GON6 (v,94L = 12.000 in Distributed Load 16.90 #/ft No Surface Restraint distance to top 7.670 ft distance to bottom 0.330 ft Summary Moments @ Surface... Point load 0.00 ft-# Total Moment 496.18 ft-# Distributed load 496.18 Total Lateral 124.05 Ibs Without Surface Restraint... With Surface Restraint... Required Depth 2.792 ft Req'd Depth 0.000 ft Press @ 113 Embed... Pressure @ Base... Actual 188.84 psf Actual Allowable 186.11 psf Allowable Surface Restraint Force �n m 10'-Orr HIGH ORCO WALL SYSTEM SITE WA 7 7 N ti FOR 70 MPH WIND @a EXPOSURE C r:,rLr•�r� #4 HORZ C aW.. ORCO 8816 C74U GROUTED ONLY @ VERT STEEL NOTE: PROVIDE (2)#4 DOWEd & 04 DROP -IN BAR AT EAW SYDEOFCONTROL )DINT 04 VERT DROP -IN BAR @ 32' O/C #8 S7D)OINT REINFORC2 4ENT @ 24' O/C (5 PLACES) PER uwSm 21-m. 04 DOWEL @ 16'0/C @ EDGE OF 8'04U. 41' 18' LEVEL GRADE BOTH SIDES X-0" CONT. NOTE.' SOLID GGOUT RETAINING PORTION OFC74U STEM DESIGN CRITERIA: 1. ALLOWABLE SOIL SEARM PRESSURE = 15W PSF 2. ALLOWABLE LATERAL PASSIVE PRESSURE= 150PCF 3. GROUT S7RENGTH = 2000 PSI @ 28 DAYS 4. REINFORCING STEEL : GRADE 40 FOR #4 54RSAND SMALLER I GRADE 60 FOR #SAND LARGER 5. SEISWC - ZONE 4, Na = 1.05 6.1500 PSI PL450MYCOMPRE&SIOHNS7REIYG7H. HALFSTRESSES USED - NO &RECTAL INSPECTION REQO. NOTES.' 1.COAX ETEBLOCKSHALLCONORMTOL47CSTD.21-i.ORCO STD. PREU M4 SPLIT FAG$ SLUMPED, OR WL7aMOCK BLOM MAYBE L.EFD ZCU GWMFORfaOI1NGSH4LLBE1PARTCLN&iT702-1/2 PARTSS AV 703-1/2 PARTS GAAVH. WITHA M40" OF 1-112 GQWW OF WA7ER A9Z SLUC P0R7L4N0CFN5VT SHALL C0 NPURM 7DA57MC I5V TYPELM - 25W PST 3. REWFOROW 57M SHALL BEDBVRMIDANO CDNFURM 70 ASIMA 615 GUM 40 FOR 04 84RSAMD 9W7LLfR GRADE 60 FOR #SAND LARGER AROVIDE 40 BAR DIAMEMR LAP FUR GRADE 40 REBNI AND 48 AAR DIAMETER LAP MR 6 R40EM. 4. REM4R S4WL BE(FNTBtM BN 77E CpYG MBL000CELL DN W fiW ITIS LOCAMD. 5. CDAUPE7FELM SWU BELAYED DNA RUNNING BOND PATTERN WITH VERTICIL CON77NUMOF71 ECFUS UNO, 6. ALL SLOQCCHI.S COMADWG VHL77CAL REM SMU BE S01M GROMP. 7. USFOBP7YPESMORTAR PROPOR7IONLD LONG UBCTABLEAU 21A1PARTCEHM 701/2PART PE70+k2PARTS aW LOOSESAND. &GROUTI RCOACRE7EBLOCK70WIPART®M9NT703 PAR7SS4ND (GROUTMAY M%?ADN 2 PART AW PF4 GRAVEL IF WEATHHC CONDIr"SAREFAVORABLEAND BLOiX UNOBS7RGX7ID CELL S)2F 5 gOFIMW TOALLOW GOOD GROL?ROW).WATER RMLL BEADDED TO PRO ME G" GROUT ROW W TA SEG REG47ION OF THE LtiNSI7U6VTS 9.&=S7EMANY BEWETSET1-1/2'A707HEFOOTINGWH E TW CONCRETE15PLA571G BL=ST 94MAYSE PIAGFD TO ErrHBZ S) GE OF T NE T RB K H TYPE fV 077NG. 10. FOD7MWSTBEPDUREDONORINTUUNDLSTUMD NATURAL SOIL OR ON CONPACIID FILL WIINA MM MUM COMPACTION OF90 %. 11. F MT ROECUOW TD BEAFTr3R FOOTING TRUKHESARE READY FOR CaVOW SAND ALL REQUIRD SAFE LS TIED IN PLACE 5EMWTM WTF0N70BEWMVTFEREWDtEDVFR77CALLSIN PLAGFAND 7HE BWOr WALL iS RSWYTO6ROUT. LZAIWARMICWNTTOLJODNT9MaW 4V01COR21Y0/CIF77E WALL 5 70 BESTLACL0 MGM 12' DRAINSTAR SUB -DRAIN CONTINUOUS PER NER569. FOLLOW MFGS INSTALLA77ON RECOM MATIONS PROVIDE OUTLET FITIM AND 4' 0THR000H NEW WALL @ 100'IN7SGVAL5. @16"O/C" 6' 04 HORZCONT. @ 11' O/C TOPAND BOTTDMASSHOWN COACHELLA VALLEY HOUSING COALITION DUNE PALMS/LA QUINTA Exp. 12/3112Toa I* s�gTF OF Ll t TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951)685-1521 Rev: 510300 User: KW-0603522, Ver 5.1.3, 22-Ju 1999, Win32 (c) 1983-99 ENERCALC Title : Dsgnr: Description Scope : Cantilevered Retaining Wall Design Job # Date: 3:30PM, 30 AUG 07 Page 1 Description DUNE PALMS 2' RETAINING W/ 8' CMU WALL ON TOP LEVEL BACKFILL 70C WIND & .258W SEISMIC Criteria Retained Height = 2.00 ft Wall height above soil = 8.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf t C, ? q>`� Wind -on Stem = 15.0 psf / (a Design Summary Total Bearing Load = 1,644 Ibs ...resultant ecc. = 10.69 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Soil Pressure @ Toe = 1,798 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,447 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 12.9 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 2.00 OK Sliding = 2.50 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 277.5 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 575.3 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK FootingDesign Results Toe Heel Factored Pressure = 2,447 0 psf Mu': Upward = 0 0 ft Mu': Downward = 0 0 ft Mu: Design = 0 1,303ft-# Actual 1-Way Shear = 0.00 12.93 psi Allow 1-Way Shear = 0.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Stem Construction # # Top Stem Stem OK Design height ft = 2.67 Wall Material Above "Ht" = Masonry Thickness = 8.00 Rebar Size = # Rebar Spacing = 32.00 Rebar Placed at = Center Design Data fb/F13 + fa/Fa = 0.732 Total Force @ Section Ibs = 110.0 Moment.... Actual ft-# = 403.0 Moment..... Allowable ft-# = 550.7 Shear..... Actual psi = 4.0 Shear..... Allowable psi = 25.8 Bar Develop ABOVE Ht. in = 20.00 Bar Lap/Hook BELOW Ht. in = 20.00 Wall Weight psf = 55.0 Rebar Depth 'd' in = 3.81 Masonry Data fm psi= 1,500 Fs psi = 20,000 Solid Grouting = No Special Inspection = No Modular Ration' = 25.78 Short Term Factor = 1.330 Equiv, Solid Thick. in = 4.90 Masonry Block Type = Medium Weight Concrete Data fc psi = Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S ` Fr Heel: Not req'd, Mu < S' Fr Key: No key defined Footing Strengths & Dimensions 4 fc = 2,500 psi Fy = 40,000 psi Min. As % = 0.0012 Toe Width = 0.00 ft Heel Width = 3.00 Total Footing Width = 30 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in 2nd Stem OK 0.00 Masonry 8.00 # 4 16.00 Edge 0.637 190.0 766.7 1,204.2 3.3 25.8 20.00 6.00 78.0 5.25 1,500 20,000 Yes No 25.78 1.330 7.60 J �NFE SSIpNq�� LLU CE31925 :1Exp- 12/31 /2008 \sT CIV��- �TF OF C A�.\F TIMOTHY S. MALLIS CIVIL ENGINEER Title: Job # ORCO BLOCK INC. Dsgnr: Date: 3:30PM, 30 AUG 07 1 Description 4510 RUTILE ST. RIVERSIDE, CA. 92509 Scope: (951)685-1521 Rev: 510300 User: KW-0603522,Ver5.1.3,22-Jun-1999,Wn32 Cantilevered Retaining Wall Design Page 2 g (c) 1983-99 ENERCALC cAdocuments and settinqs\tmallis\mv document Description DUNE PALMS 2' RETAINING W/ 8' CMU WALL ON TOP LEVEL BACKFILL 70C WIND & .258W SEISMIC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs It ft-# Heel Active Pressure = 157.5 1.00 157.5 Soil Over Heel = 536.7 1.83 983.9 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 120.0 7.00 840.0 Soil Over Toe = SeismicLoad = Surcharge Over Toe = Stem Weight(s) — 611.4 0.33 203.8 Total = 277.5 O.T.M. = 997.5 Earth @ Stem Transitions = Resisting/Overturning Ratio = 2.00 Footing Weight = 450.0 1.50 675.0 Vertical Loads used for Soil Pressure = 1,643.6 Ibs Key Weight = Vert. Component = 45.5 3.00 136.5 Vertical component of active pressure used for soil pressure Total = 1,643.6 Ibs R.M.= 1,999.2 QRpFESS/ ANY CE31925 N TI Exp. 12/31 /2008 CIVIL ��Q' )�OF CAL�F��/ 7--10" & 10" HIGH CRC® 32" SQ. PILASTER V= AREA - Do NOT GROUT ABOVE GROUND GROUT BOTTOM 2' OF RETAfNWO-7 L—,P TIES O 24' 0/C J N VERT O EACH CORNER AND AS SHOWN W16 OR 5516 CAW - BLOGYI CELLS TO BE SOLID GROUTED ONLY. 32" SO. I PILASTER - SEE DETAIL SELOW (4) #4 VLrT DROP -IN BARS ® EA. CqRNER CELL AND AS OWN 3 77ES @24" 0/C h Q �e 0 3 2 ® U � U Q Q - O O (8) f4 D WELS W/ 24" MIN. EXTENSI INTO CMU. — ® EA. C ER CELL 33" AND AS OWN 12" EQUAL 2 a— oc' �I R {r Q V 14 HORZ ® 8" O/C E. 32" SO. 3'-3" SQUARE FOR 7-10" HIGH 3'-9" SQUARE FOR 10" HIGH DESIGN 17 nBVA: 1. ALLOWABLE SOIL BEARING PRESSURE =1500 PSF 2. ALLOWABLE LATERAL PASSIVE PRESSURE = 150 PCF 3. GROUT STRENGTH = 2000 PSI @ 28 DAYS 4. REINFORCING STEEL : GRADE 40 FOR #4 BARS AND SMALLER 6 GRADE 60 FOR #5 AND LARGER 5. SEMWC - ZONE 4, Na = 1.05 6. 1500 PSI MASONRY COMPRESSION STRENGTH. HALF STRESSES' USED - NO SPECIAL INSPECTION REQD. 574I1xi1 1. CONCRETE BLOCK SHALL CONFORM TO UBCSTD. 214. ORCO STD. PRECL40N, SPLIT FACE; SLUMPED, OR W&-X.ROCK BLOCK MAYBE USED 2. CONCRETE FOR F0077NG SHILL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL W17HA MAXIMUM OF I-112 GALLONS OF WATER PER S4CK PORTIAN'D CEMENT SHALL CONFORM TO ASTM C 150 TYPE H.Fc = 1500 P57 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO A57M A 615 GRADE 40 FOR #4 BARS AND SMALLER, GRADE 60 FOR #SAND LARGER. PROVIDE 40 BAR DIAMETER LAP FOR GRADE 40 REPAR AND 48 BAR DIAMETER LAP FOR GRADE 60. 4. REB4R SHILL BE CENTERED IN THE CONCRETE BLOCK CELL IN WMCH IT IS LOCA7W. 5. CONCRETE BLOCK SHALL BE LAYED IN A RUNNING BOND PATTERN WITH VERTICAL CONT INUITY OF THE M l [' UNO. 6. ALL BLOCK CELLS MWAINING VER771AL REBAR SHALL BESOIID GROUTED. 7. USE OBP TYPE 5 MORTAR PROPIORWONED USING UBC TABLE NO. 21-A I PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSESAND. B. GROUT FOR CONCRETE BLOCK TORE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAYCAYTAIN 2 PARTS 3/8' PEA GRAVEL IF WEATHER CONDI'7fOWLSARE FAVORABLEAND BLOCK UMOSS MUCTED CELL .SIZE 15 SU1i77CI0VT TO ALLOW GOOD GROUT ROW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE C0AWTUENTS. 9. BLOCK STEM MAY BE WET-5EF 1-112"INTO THE fUOTING WFBLE THE CONCRETE IS PL4577C BLOCK STEM M4Y HE PLACED TO EITHER EDGE OF THE TRENCH TYPE ROOTING. 10. FOOTING msr BE R7URED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MIMMUM COMPACTION OF 90 %. 11. FIRST INSPECTION TO BEAFTER F0077NG THE ONES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TTED IN PLACEE, SECOND 176PEC77ON TO BE WHEN THE REQUIRED VERTICAL 15IN PLACE AND THE BLOCK WALL 15 READY TO GROVE IZ MAXIMUM CONTROL JOINT SPACING: 40' O/C OR 20' 0/CIF THE SOLID GROUT WALLIS TO BE STUCCO COATED. RETAINING COACHELLA VALLEY HOUSING COALITION DUNE _ PALMS/LA QUINTA EQUAL PILASTER NO. 1 W/ b INTEGRAL COLOR SLUMPSTONE E' CL1 23 1 . Exp, 12/31/20U TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. Job # Date: 9:30AM, 13 DEC 07 4510 RUTILE ST. Title : Dsgnr: Description RIVERSIDE, CA. 92509 Scope (951) 685-1521 • Rev51930D Page 1 [U..;:KW-OB03522.Ver5.1.3.22Jurr1998,Win32 Cantilevered Retaining Wall Design (c) 1983.89 ENERCALC c:\documents and settings\tmallis\mv documer Description DUNE PALMS V RETAINING W/ 32 X 32 PILASTER T LEVEL BACKFILL 70C WIND & .258W SEISMIC W/ 4' WIDE FOOTING ALONG WALL Criteria Retained Height = 1.00 ft Wall height above soil = 7.00ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3-00 in Soil Density = 115.00 pcf Wind on Stem = 45.0 psf Design Su_h mmary Total Bearing Load = 2,062 Ibs ...resultant ecc. = 9.61 in Soil Data T Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Stem Construction T Design height ft = Wall Material Above "Ht" _ Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Ibs = Moment.... Actual ft-# = Moment..... Allowable ft-# = Shear..... Actual psi = Shear..... Allowable psi = Soil Pressure @ Toe = 1,668 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,313 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 15.2 psi OK Footing Shear @ Heel = 3.8 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 1.96 OK Sliding = 2.18 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 385.0 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 721.9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK Footing Design Results wToe Heel Factored Pressure = 2,313 0 psf Mu': Upward = 1,593 0 ft-# Mu': Downward = 209 342 ft-# Mu: Design = 1,385 342ft-# Actual 1-Way Shear = 15.17 3.82 psi Allow 1-Way Shear = 85.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Bar Develop ABOVE Ht. Bar Lap/Hook BELOW Ht. Wall Weight Rebar Depth 'd' Masonry Data in = in = psf = in = Stem Footing Strengths & Dimensions fc = 2,500 psi �Fy = 40,000 psi Min. As % = 0.0012 Toe Width Heel Width Total Footing Width Footing Thickness Key Width Key Depth Key Distance from Toe Cover @ Top = 3.00 in 2nd Stem OK Stem OK 2.67 0.00 Masonry Masonry 16.00 16.00 # 4 # 4 8.00 8.00 Center Edge 0.218 239.9 639.2 2,926.8 2.9 25.8 20.00 20.00 177.1 7.75 f m psi = 1,500 Fs psi = 20,000 Solid Grouting = Yes Special Inspection = No Modular Ratio'n' = 25.78 Short Term Factor = 1.330 Equiv. Solid Thick. in = 15.62 Masonry Block Type = Medium Weight Concrete Data f c psi = Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S * Fr Heel: Not req'd, Mu < S * Fr Key: No key defined 0.209 332.5 1,423.3 6,815.5 2.3 25.8 20.00 6.00 177.1 13.00 1,500 20,000 Yes No 25.78 1.330 15.62 = 0.96 ft = 2.29 12.00 in 0.00 in 0.00 in 0.00 ft @ Btm.= 3.00 in s w3 CE31925 Exp.12/3-1/2008 yj. �s / \Tq CIVtI cC� TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951) 685-1521 Title : Dsgnr: Description Scope : Rev. 510300 User. K'FN 99 522. Ver 5.1.3. 22-Jun-1999, Win32 Cantilevered Retaining Wall Design (c) 1983 ENERCALC Job # Date: 9:30AM, 13 DEC 07 Page 2 Description DUNE PALMS V RETAINING W/ 32 X 32 PILASTER T LEVEL BACKFILL 70C WIND & .258W SEISMIC W/ 4' WIDE FOOTING ALONG WALL Summary of Overturning & Resisting Forces & Moments -s ':.K; s:.�__..n_i�•,�i. ._. �.�cae^.=�c:.._^Rt�r�_��•c-csxa:-���> .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# Ibs ft ft-# Heel Active Pressure = 700 067 467 Soil Over Heel = 110.2 2.77 305.4 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @_ Stem Above Soil = 315.0 5.50 1,732.5 Soil Over Toe = 27.6 0.48 13.2 SeismicLoad = Surcharge Over Toe = Stem Weight(s) - 1,417.0 1.63 2,302.6 Total = 385.0 O.T.M. = 1,779.2 Earth @ Stem Transitions = Resisting/Overturning Ratio = 1.96 Footing Weight = 487.5 1.63 792.2 Key Weight = Vertical Loads used for Soil Pressure = 2,062.4 Ibs Vert. Component = 20.2 3.25 65.7 Vertical component of active pressure used for soil pressure Total = 2,062.4 Ibs R.M.= 3,479.0 f �ij f��i ry `l••Lf:': 4 c CE31,25 1: ' Exp.12/31/2006 (� a�rr TIMOTHY S. MALLIS CIVIL ENGINEER Title: Job # ORCO BLOCK INC. Dsgnr: Date: 9:30AM, 13 DEC 07 4510 RUTILE ST. Description RIVERSIDE, CA. 92509 Scope (951) 685-1521 Rev: 510300 User:KW-0603522.Ver5.1.3.22-Jun-1999,Wn32 Cantilevered Retaining Wall Design Page 1 (c) 1983-99 ENERCALC c:ldocuments and settingsltmallislmy document Description DUNE PALMS V RETAINING W/ 8' 32 X 32 PILASTER T LEVEL BACKFILL 70C WIND & .258W SEISMIC W/ 4' WIDE FOOTING ALONG WALL Criteria Retained Height = 1.00 ft Wall height above soil = 9.00 It Slope Behind Wall = 0.00 : 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf Wind on Stem = 45.0 psf Design Summary Total Bearing Load = s �2,528 lbs ...resultant ecc. = 11.91 in Soil Pressure @ Toe = 1,910 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,652 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 21.3 psi OK Footing Shear @ Heel = 4.7 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 1.83 OK Sliding = 2.11 OK Sliding Ca►cs (Vertical Component Used) Lateral Sliding Force = 475.0 lbs less 100% Passive Force = - 117.2 lbs less 100% Friction Force = - 884.7 lbs; Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Stem Construction Design height a ft = Wall Material Above "Ht" _ Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section lbs = Moment.... Actual ft-# = Moment.....Allowable ft-# = Shear ... ..Actual psi = Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results` Toe Heel Factored Pressure = 2,652 0 psf Mu': Upward = 2,540 0 ft-# Mu': Downward = 297 482 ft-# Mu: Design = 2,242 482 ft-# Actual 1-Way Shear = 21.28 4.73 psi Allow 1-Way Shear = 85.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Shear..... Allowable psi = Bar Develop ABOVE Ht. in = Bar Lap/Hook BELOW Ht. in = Wall Weight psf = Rebar Depth 'd' in = Masonry Data p Stem Footing Strengths 8r Dimensions r fc = 2,500 psi �Fy = 40,000 psi Min. As % = 0.0012 Toe Width = 1.21 ft Heel Width = 2.54 Total Footing Width =7� Footing Thickness = 12.00 in Stem OK 2.67 Masonry 16.00 # 4 8.00 Center 0.413 329.9 1,208.9 2,926.8 4.0 25.8 20.00 20.00 177.1 7.75 fm psi= 1,500 Fs psi = 20,000 Solid Grouting = Yes Special Inspection = No Modular Ratio'n' = 25.78 Short Term Factor = 1.330 Equiv. Solid Thick. in = 15.62 Masonry Block Type = Medium Weight Concrete Data fc psi = Fy psi = Key Width Key Depth Key Distance from Toe Cover @ Top = 3.00 in 2nd Stem OK 0.00 Masonry 16.00 # 4 8.00 Edge 0.328 422.5 2,233.3 6,815.5 3.0 25.8 20.00 6.00 177.1 13.00 1,500 20,000 Yes No 25.78 1.330 15.62 0.00 in 0.00 in 0.00 ft @ Btm.= 3.00 in Other Acceptable Sizes & Spacings Toe: #4@ 19.75 in, #5@ 30.50 in, #6@ 43.25 in, #7@ 48.25 in, #8@ 48.25 in, #9@ 4 Heel: Not req'd, Mu < S " Fr Key: No key defined f CE31925 1 Exp. 12/31 /202 r OF TIMOTHY S. MALLIS CIVIL ENGINEER Title: Job # ORCO BLOCK INC. Dsgnr: Date: 9:30AM, 13 DEC 07 Description: - 4510 RUTILE ST. RIVERSIDE, CA. 92509 Scope (951) 685-1521 - Rev: 510300 User: KW-0603522,Ver5.13.22-Jun-1999,Win32 Cantilevered Retaining Null Design Page 2 g (C) 198199 ENERCALC c:\documents and settings\tmallis\mv document Description DUNE PALMS V RETAINING W/ 8' 32 X 32 PILASTER T LEVEL BACKFILL 70C WIND & .258W SEISMIC W/ 4' WIDE FOOTING ALONG WALL Summary of Overturning & Resisting Forces & Moments "'-•CC".::.L:gSCa�'^'_:.L'^T'. �'?S.i:�3'3?�.i"^.'g+-:�� J*°o'PP�_^_T�.I!_3Y.wTi'AiP_9'�"CS.'Sl�_'-'-' `!L?A:A..:..."�"^S^��:?... .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# lbs ft ft-# Heel Active Pressure = 70.0 0.67 46.7 Soil Over Heel = 139.0 3.15 437.1 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 405.0 6.50 2,632.5 Soil Over Toe = 34.7 0.60 21.0 SeismicLoad = Surcharge Over Toe = Stem Weight(s) - 1,771.2 1.88 3,321.0 Total = 475.0 O.T.M. = 2,679.2 Earth @ Stem Transitions = Resisting/Overturning Ratio = 1.83 Footing Weight = 562.5 1.88 1,054.7 Vertical Loads used for Soil Pressure = 2,527.6 Ibs Key Weight = Vert. Component = 20.2 3.75 75.8 Vertical component of active pressure used for soil pressure Total = 2,527.6 Ibs R.M.= 4,909.6 �A� S f ,+ Cc 3 1 S2 r i Exp. 12/31 /2-008 ., 6' HIGH ORCO WALL SYSTEM SITE WALL FOR 80 MPH WIND pia EXPOSURE C I OPTIONAL RAT CAP ESIGN CRITERIA: ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF ALLOWABLE LATERAL PASSIVE PRESSURE = 150 PCF GROUT STRENGTH = 2000 PST @ 28 DAYS. REINFORCING STEEL : GRADE 40 FOR #4 BARS AND SMALLER BADE 60 FOR #5AND LARGER SE 5MIIC - ZONE 4, Na = 1.05 1500 PSI MASONR Y COMPRESSION STRENGTH. GOLF STRESSES USED - NO SPECIAL INSPECTION REQD. S:' TNCRETE BLOCK SHALL CONFORM TO UBC STD. 11-4. ORCO PRECISION, SPLIT FACE, SLUMPED, OR WLDGELOCK BLOCK BE U5ED NVOWTE FOR R7077NG SHALL BE 1 PART CEMENT TO 2-1/1 IS SAND TO 3-1/1 PARTS GRAVEL WITH A MAXIMUM OF 1-112 .ONS OF WATER PER SACK PORTLAND CEMENT SHALL CONFORM S M C 150 TYPE LTIV. Fc = 2000 PST 7NFORGNG STEEL SHALL BE DEFORMED AND CONFORM TO NA 615 GRADE 40 FOR #4 BARS AND SMALLER, GRADE 60 FOR NO LARGER PROVIDE 40 BAR DIAMETER LAP FOR GRADE 40 IR AND 46 BAR DIAMETER LAP FOR GRADE 60. =BAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN CH IT IS LOCATED. ONCRETE BLOCK SHALL BELAYED IN A RUNNING BOND TERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 1 BLOCK CELLS CONTAINING VERTICAL REZ{AR SHALL BE SOLID UT D. SE OBP TYPE S MORTAR PROPORTIONED USING UBC TABLE NO. . 1 PART CE 4ENT TO 1/1 PART LIME TO +1/1 PARTS DAMP, SE SAND, ROUT FOR CONCRETE BLOCK TO BE 1 PART CEMENT TO 3 P5 SAND (GROUT MAY CONTAIN 1 PAM 3/8" PEA GRAVEL IF ITHER CONDITIONS ARE FAVORABLEAND BLOCK UNOBSTRUCTED . SIZE LS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER LL BE ADDED TO PRODUCE GOOD GROUT RAW WITHOUT REGATION OF THE CONSIMENTS LOCK STEM MAY BE WET SET 1-1/2"INTO THE FOOTING WHILE CONCRETE IS PfAS77C BLOCK STEM MAY BE PLACED TO fER EDGE OF THE TRENCH TYPE FOOTING. 10077NG MUST BE POURED ON OR INTO UNDISTURBED URAL SOIL OR ON C 001PACTED FILL WITH MIAOMUM 1PAC77ON OF 90 %. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE DY FOR COACRETEAND ALL REQUIRED STEEL IS TIED IN PLACE OND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS M SAND THE BLOCK WALL IS READY TO GROUT. MAXIMUM CONTROL JOINT SPACING: 40' O/C OR 20' O/C IF THE 115 TO BE STUCCO COATED. COACHELLA VALLEY HOUSING COALITION DUNE PALMS/LA QUINTA WALL TYPE 1 W/ INTEGRAL COLOR SLUMPSTONE TIMOTHY S. MALLIS CIVIL ENGINEER Title: Job # ORCO BLOCK INC- Dsgnr: Date: 10:24AM, 13 DEC 07 Description 4510 RUTILE ST. RIVERSIDE, CA. 92509 Scope: (951)685-1521 Rev: 51030D �/�� Page 1 User :KVJ-0603522,Ver5.1.3,22-Jun-1999,Wn32 Cantilevered Retaining Wall Design (c)1983-99 ENERCALC c:ldocuments and settinosltmallislmv documer Description DUNE PALMS V RETAINING W/ 5'-6" WALL TYPE 1 T LEVEL BACKFILL 70C WIND & .258W SEISMIC Criteria Retained Height = 1.00 ft Wall height above soil = 5.50 ft Slope Behind Wall = 0.00 : 1 Height of Soil over Toe = 3.00 in Soil Density = 115.W pcf Wind on Stem = 16.9 psf Design Surn- Total Bearing Load s = 740 Ibs ...resultant ecc. = 6.93 in Soil Data Allow Soil Bearing = 2,000.0 psff Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Soil Pressure @ Toe = 1,168 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,591 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 6.4 psi OK Footing Shear @ Heel = 3.1 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 1.64 OK Sliding = 2.31 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force 163.0 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 259.1 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK Footing Design Results - Toe Heel Factored Pressure = 1,591 0 ps Mu': Upward = 469 0 ft Mu': Downward = 96 168 ft Mu: Design = 373 168 ft Actual 1-Way Shear = 6.40 3.07 ps Allow 1-Way Shear = 85.00 85.00 ps Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Stem COilStruction Top Stem Stem OK Design height ft = 1.00 Wall Material Above "Ht" = Masonry Thickness = 6.00 Rebar Size = # 4 Rebar Spacing = 32.00 Rebar Placed at = Center Design Data fb/FB + fa/Fa = 0.787 Total Force @ Section Ibs = 93.0 Moment.... Actual ft­# = 255.6 Moment..... Allowable ft-#= 324.8 Shear..... Actual psi = 4.2 Shear..... Allowable psi = 25.8 Bar Develop ABOVE Ht. in = 20.00 Bar Lap/Hook BELOW Ht. in = 20.00 Wall Weight psf = 45.4 Rebar Depth 'd' in = 2.75 Masonry Data --- fm psi= 1,500 Fs psi = 20,000 Solid Grouting = No Special Inspection = No Modular Ratio 'n' = 25.78 Short Term Factor = 1.330 f Equiv. Solid Thick. in = 3.90 # Masonry Block Type = Medium Weight Concrete Data fc psi= Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S * Fr Heel: Not req'd, Mu < S * Fr Key: No key defined Footing Strengths & Dimensions c =- 2,500=psi Fy _ 40,000 psi Ain. As % = 0.0012 roe Width = 0.75 ft -feel Width = 1.25 Total Footing Width = -ootmg Thickness = 12.00 In 4ey Width = 0.00 in Cey Depth = 0.00 in <ey Distance from Toe = 0.00 ft over @ Top = 3.00 in @ Btm.= 3.00 in 2nd Stem OK 0.00 Masonry 6.00 # 4 24.00 Edge 0.983 110.5 354.4 360.5 3.7 25.8 20.00 6.00 62.6 2.75 1,500 20,000 Yes No 25.78 1.330 5.60 CF31925 u' Exp. 12/,1 /2008 ' d, n- �q�� OF AI 1F�`��\P TIMOTHY S. MALLIS CIVIL ENGINEER Title: ORCO BLOCK INC. Dsgnr: Description 4510 RUTILE ST. RIVERSIDE, CA. 92509 Scope (951)685-1521 Job # Date: 10:24AM, 13 DEC 07 Rev: 510300 r-'Bye L User. KW-0603522, Ver 513. 22-Jun-1999 W1n32 Cantilevered Retaining Wall Design 0) 1983-99 ENERCN-c c:ldocuments and settings\trnallislmy document Description DUNE PALMS V RETAINING W/ 5'-6" WALL TYPE 1 T LEVEL BACKFILL 70C WIND & .258W SEISMIC Summary of O9 verturtiin & Resistn Forces Moments. ..... OVERTURNING ..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 70.0 0.67 46.7 Soil Over Heel = 86.3 1.63 140.2 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 93.0 4.75 441.5 Soil Over Toe = 21.5 0.38 8.1 SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 312.1 1.00 312.1 Total = 163.0 O.T.M. = 488-2 Earth @ Stem Transitions = Resisting/Overturning Ratio = 1.64 Footing Weight = 300.0 1.00 300.0 Key Weight = Vertical Loads used for Soil Pressure = 740.2 lbs Vert. Component = 20.2 2.00 40.4 Vertical component of active pressure used for soil pressure Total = 740.2 lbs R.M.= 800.8 J CE31925 Exp. 12/31 /2008 S/" C(VlL RAT CAP DE576NO UTEWA: 1. ALLOWABLE SO& BEARIAG PRERRM. ISM PSF 2 ALLOWABLE LATElM hLgnT FRESSURF=1507KF 3. GVUr57R8Yf.W - 2GM PSI 26DAYS. 4.RE ORCVG STEEL: GRADE 40 MR A454RSAPM SANIER GUOE 60FOR PS AND LARGER 5. SE3MC-ZONE 4, N14 - t05 G 13W PSI MASOMRYLZWPR!SWON STRETG77L HALFSTREZES U5W - NO SPCIIAL NWEC77701V RLip, NOTE, L CO CREFF NDCX SFWLL CONFORM ro L.WSTD 214. Cl ( STD. PREP SPITFACT SLIUFED, ON WLO[SOOSFLOCX MAYBE WED z Cv.CXm Rw FO'JTAGSFWL W 19ANTCE+BVT TO. 1/2 PARTS SAFD To 1.112 AW?S GRAY WITMA MQ@MM CF I-{Q frif.lO16 C1` WATER PR54CX POKnAV9 C8EN19W1 CAWMM TO AS/ 0750TYPE Eft -2RDi 3. ROAFOAC G SM SW1 BE DEFURMED AND CDY-V"70 A57N A 6I5 CiL 40 FOR AN BARS AMD 94VLM CRAVE 602W ISAW L4RS91 PROVIDE 40 BAR LAP POP GRADE 40 RE W AND 48 BAR DIAMETER LAP FOR LRADF 60. 4. MAV SFWL BE CSWERE07R THE ONKRETE AL=CHI M WavaFnalDDa7P.� s CUM7tEPFB111Q"SINII BELAYEDINA RUARDW DOD PATPERN•TTF YDRIfiv COMDNRIY fF 7FE MLS LNG, 6 All BLOOC CELLS CL77TADUW VERTYC L REBAPSAND. BE50"D GKUifD. T.IHCWTYPES AFORM PR0YKRT70MDLGW LOC TABLC O z1w 7 vAPTCRENT ro 1/I FAe7 LLPETa+Yz MRISLPAMv, LOD.SEs4b. BCFDUTFUPCTl'1[RFIEm 1® TIU3 PwATArT55ADOPOOTNAYCWAVV F7SWF sVEZSLIIO6ARER40QEAFV&WaL#44005 sFTAU,0WaPDr4 MTPR 9WBEAVPRODUCEGM06RDaTFfOwTI7OPT SRiECATIOMOFTE CON4RA`NTS a LRCUCSTEN FpYBWFT3ETl-1/r1NiD 77E WOTAB W/RIE THE WAC ISPAS7M ALOMSIERM4YBEPLACIDro EPFMEt Si ZOFTPE7ROWCHTYPE70OIDA- Ia FOOWV MKTBE PoIAPED ON OR I IM= 7LRRW FWTLAM SOL CA OY[gWAC7ED PILL WTTHA M Wff R NIACrJ 1Y OF90W tl. FDtST INSPWIA]M ro BEAFPHt FDOIRYG PRBRSESARE READY FOP C0110" AAO ALL A[QL1 STM a 7197 MFUSLE SEO]MDEPELDCN ro BE WHEN TFEAEC,RARHP VM77M aM PIACEAMD TiE BWM WALL a RE401'TV 690t7 . Iz MWMM CON/FIX JOWT 59ACI W OY1- CA 30 WCIE ME WALLa7OEs71 amPP51 10' SETBACK I I I I I I I I I I I L------J I I I I I I I I I I r______; I I I I I I I I I I I I I I I I I I I I I I I I I I I TYPE 2 RETAINING WALL ORCO 6616 C74U GROUTED ONLY @ VERT 57M V BAR. PROVIDE 24' LAP INTO 8X6X16 OVU. #6 57D JOINT REINFORC EMENr o 014"0/C (3 PLACES) PER UBC STD. 21-10. USE #5STD. FOR b SLUMP BLOCK #4 HORZ CONT. @ 24' O/C LEVEL S407 FILL BA V-M W/ S=BACKRLL SOIL. o III _ WALL TYPE 3 W/ INTEGRAL COLOR SLUMPSTONE III_ o COACHELLA VALLEY Q ' DOWa HOUSING COALITION z' an DUNE PALMS/LA QUANTA bd-11- 12'DRAIKSTAR SUB -DRAIN CONTINMU5 PERNER-569. FOLLOW MfVS INSTALLATION REMMENDA77ONS. PROVIDEOUTLETFrMAfG AND 4' D THROUGH NEW WALL @ 100' INTERVALS. �-I WEAR ti • #4 12' O/C 0PAND RZ. CONT. @A®SSNOWN �TiOM 'B' 1J �1 'A' 'B A 'F' DOWEL 'G' VERT V BAR 2'-6' #4032' 0/C 33' #4®320/C ' #4f32' O/C P4 -F'-0- 12. L 6' F Z'-8' Z'-9' #4®32' 0/C 4/' #4�32• oic #4t32' 0/C P7' 12' L 6'� 3'-4' 3'-0' #4�16' 0/C 49' L #4032' 01C #4®16' 0/C 12' 4'-0' 3'-3' #5016' 0/C I5T #4f32' 0/C #4@16' 0/C `' U- -Ar 1925� 12 31/200r i ;ilk ' TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951) 685-1521 Rev: 510300 User :KW-0603522.Ver5.1.i, 22-Jun-1999 Wn32 Cantilevered Retaining Wall Design I (c) 1983-99 ENERCALC Title : Dsgnr: Description Scope : Job # Date: 4.40PM, 12 DEC 07 Page 1 Description DUNE PALMS 2' RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Criteria Retained Height = 2.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf Wind on Stem = 16.9 psf Design summary :L..��S�1C•i1_Pr. - .Yv:�iS.4L..+v'i..v�4i:�c Total Bearing Load = 1,250 Ibs ...resultant ecc. = 9.25 in Soil Pressure @ Toe = 1,739 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable Soil Data Footing Strengths &Dimensions f Allow Soil Bearing = 2,000.0 psf fc = 2,500 psi Fy = 40,000 psi Equivalent Fluid Pressure Method Min. As % = 0.0012 Heel Active Pressure = 35.0 Toe Width = 0.00 ft Toe Active Pressure = 0.0 Heel Width = 2.50 Passive Pressure = 150.0 Total Footing Width = 2.50- Water height over heel = 0.0 ft Footing Thickness = 12.00 in FootingjjSoil Friction = 0.350 Soil height to ignore Key Width 0.00 in = for passive pressure = 0.00 in Key Depth 0.00 in Key Distance from Toe - 0.00 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in Stem Construction Top Stem 2nd z s ^ ' K=n •Y -x Stem OK Stem OK Design height ft = 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Rebar Placed at = Center Edge ACI Factored @ Toe = 2,346 psf . fb1FB + fa/Fa �/FB _ 0.937 0.791 ACI Factored @Heel = D psf Total Force @ Section Ibs = 101.4 171.4 Footing Shear @ Toe = 0.0 psi OK Moment.... Actual ft-# = 304.2 553.7 Footing Shear @ Heel = 10.3 psi OK Moment..... Allowable ft-# = 324.8 699.6 Allowable = 85.0 psi Shear..... Actual psi = 4.5 2.9 Wall Stability Ratios Overturning = 1.78 OK Shear ..... Allowable psi = 25.8 22.3 Sliding = 2.14 OK Bar Develop ABOVE Ht. in = 20.00 20.00 Sliding Calcs (Vertical Component Used) Bar Lap/Hook BELOW Ht. in = 20.00 6.00 Lateral Sliding Force = 258.9 Ibs Wall Weight psf = 42.0 78.0 less 100% Passive Force = - 117.2 Ibs Rebar Depth V in = 2.75 5.25 less 100% Friction Force = - 437.6 Ibs Masonry Data Added Force Req'd = 0.0 Ibs OK f m Fs psi = psi = 1,500 20,000 1,500 20,000 ....for 1.5 : 1 Stability = 0.0 Ibs OK Solid Grouting = No Yes Footing Desi n Results Special Inspection = No No . �__- Modular Ratio'n' = 25.78 25.78 Toe Heel Short Term Factor = 1.330 1.150 Factored Pressure = 2,346 0 psf Equiv. Solid Thick. in = 3.90 7.60 Mu': Upward = 0 0 ft-# Masonry Block Type = Medium Weight Mu': Downward = 0 0 ft-# Concrete Data Mu: Design = 0 941 ft-# fc psi= ActualI -Way Shear = 0.00 10.32psi Fy psi= Allow 1-Way Shear = 0.00 85.00 psi other Acceptable Sizes & Spacings Toe Reinforcing = None Spec'd Toe: Not req'd, Mu < S ' Fr Heel Reinforcing = None Spec'd Heel: Not req'd, Mu < S . Fr Key Reinforcing = None Spec'd Key: No key defined �- Jr c CE5 Exp. 12/a /2008 � hi CIVIL U` CAUr TIMOTHY S. MALLIS CIVIL ENGINEER Title: ORCO BLOCK INC. Dsgnr: Description 4510 RLITILE ST. RIVERSIDE, CA. 92509 Scope: (951) 685-1521 Job # Date: 4:40PM, 12 DEC 07 User KV4-0603522, Ver 5.1.3. 22-Jun-1999, Win32 Cantilevered Retaining Wall Design rays c (c) 198a-99 ENERCALC cAdocuments and settinpsltmallislmv document Description DUNE PALMS 2' RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Summar�r of Overturning & Resistin_g Forces &Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Heel Active F ressure = )Dl.Z ).uv Toe Active Pressure = 0.42 Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 101.4 6.00 SeismicLoad = Total = 258.9 O.T.M. _ Resisting/Overturning Ratio = 1.78 Vertical Loads used for Soil Pressure = 1,250.2 Ibs Vertical component of active pressure used for soil pressure 157.5 Soil Over Heel = Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = 608.4 Soil Over Toe Surcharge Over Toe = Stem Weight(s) _ 765.9 Earth @ Stem Transitions = Footing Weight = Key Weight = Vert. Component = Total = 421.7 1.58 667.6 KM 408.0 0.28 115.0 375.0 1.25 468.7 45.5 2.50 113.8 1,250.2 Ibs R.M.= 1,365.1 u] a CE31��� Exp. 12/ 31 /20 j,6 TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. ` RIVERSIDE, CA. 92509 (951) 685-1521 Title : Dsgnr: Description Scope: Rev: 510300 User KW-0603522, Ver5.1.3, 22-Jun-1999, Win32 Cantilevered Retaining Wall Design ICI 15B3-99 ENERCALC I Job # Date: 4:40PM, 12 DEC 07 Description DUNE PALMS 2'-8" RETAINING W16' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Criteria Retained Height = 2.67ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf Wind on Stem = 16.9 psf Design Summer Total Bearing Load = 1,581 Ibs ...resultant ecc. = 8.79 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingjjSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Soil Pressure @ Toe = 1,641 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,198 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 14.2 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 2.05 OK Sliding = 1.99 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 337.1 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 553.2 lbs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK Footing Design Results Toe Heel Factored Pressure = 2,198 0 ps Mu': Upward = 0 0 ft Mu' : Downward = 0 0 ft Mu: Design = 0 1,166ft Actual 1-Way Shear = 0.00 14.20 psi Allow 1-Way Shear = 0.00 85.00 ps Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Stem Construction # = Top Stem Stem OK Design height ft = 2.67 Wall Material Above "Hf' = Masonry Thickness = 6.00 Rebar Size = # 4 Rebar Spacing = 32.00 Rebar Placed at = Center Design Data fb/FB + fa/Fa = 0.937 Total Force @ Section Ibs = 101.4 Moment.... Actual ft-# = 304.2 Moment..... Allowable ft-# = 324.8 Shear..... Actual psi = 4.5 Shear..... Allowable psi = 25.8 Bar Develop ABOVE Ht. in = 20.00 Bar Lap/Hook BELOW Ht. in = 20.00 Wall Weight psf = 42.0 Rebar Depth 'd' in = 2.75 Masonry Data - f m psi = 1,500 Fs psi = 20,000 Solid Grouting = No Special Inspection = No Modular Ration' = 25.78 Short Term Factor = 1.330 f Equiv. Solid Thick. in = 3.90 Masonry Block Type = Medium Weight # Concrete Data fc psi= Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S ' Fr Heel: Not req'd, Mu < S' Fr Key: No key defined Page 1 Footing Strengths & Dimensions 'c = 2,500 psi Fy = 40,000 psi Min. As % = 0.0012 Toe Width = 0.00 ft Heel Width = 2.75 Total Footing Width = Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in 2nd Stem OK 0.00 Masonry 8.00 # 4 32.00 Edge 0.981 226.2 686.0 699.6 3.8 22.3 20.00 6.31 78.0 5.25 1,500 20,000 Yes No 25.78 1.150 7.60 TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951) 685-1521 Title : Dsgnr: Description: Scope: Job # Date: 4:40PM, 12 DEC 07 Rev: 510300 Page 2 User: KW-0603522. Ver 5. 1.3. 22-Jun- 1999, ~32 Cantilevered Retaining Wall Design l-1c11983-99ENERCALC c:\documents and settings\tmallislmy document Description DUNE PALMS 2'-8" RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Summary], of Overturnin 8� Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# lbs ft ft-# Heel Active Pressure = 235.7 1.22 288.3 Soil Over Heel = 639.7 1.71 1,092.8 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 101.4 6.67 676.3 Soil Over Toe = SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 460.3 0.29 132.4 Total = 337.1 O.T.M. = 964.7 Earth @ Stem Transitions = Resisting/Overturning Ratio = 2.06 Footing Weight = 412.5 1.38 567.2 Key Weight = Vertical Loads used for Soil Pressure = 1,580.5 Ibs Vert. Component = 68.1 2.75 187.3 Vertical component of active pressure used for soil pressure Total = 1,580.5 Ibs R.M.= 1,979.7 `...r i , `a. ' CF.31925 �z Exp. 12/3114 l i l/ ��9T1C1VIL�f� �✓ C�f V TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951) 685-1521 Rev: 510300 User KW-0603522. Ver 5 1 3. 22-Jun-1999, Wm32 (.) 1983-99 ENERCALC Title: Dsgnr: Description Scope: Cantilevered Retaining Wall Design Job # Date: 4.40PM, 12 DEC 07 Description DUNE PALMS T-4" RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Criteria Retained Height = 3.33 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf Wind on Stem = 16.9 psf Design Summary Total Bearing Load = 1,950 Ibs ...resultant ecc. = 8.58 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 0.0 ft FootingIlSoil Friction = 0.3S0 Soil height to ignore for passive pressure = 0.00 in Soil Pressure @ Toe = 1,657 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,207 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 18.6 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 2.26 OK Sliding = 1.86 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 429.5 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 682.5 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK FootingDesi n Results Toe Heel Factored Pressure = 2,207 0 ps Mu': Upward = 0 0 ft Mu': Downward = 0 0 ft Mu: Design = 0 1,457ft Actual 1-Way Shear = 0.00 18.65 ps Allow 1-Way Shear = 0.00 85.00 ps Toe Reinforcing = None Specd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Stem Construction # Top Stem su,y= Stem OK Design height ft = 3.33 Wall Material Above "Ht" = Masonry Thickness = 6.00 Rebar Size = # 4 Rebar Spacing = 32.00 Rebar Placed at = Center Design Data fb/FB + fa/Fa = 0.937 Total Force @ Section Ibs = 101.4 Moment.... Actual ft-# = 304.2 Moment..... Allowable ft-# = 324.8 Shear..... Actual psi = 4.5 Shear..... Allowable psi = 25.8 Bar Develop ABOVE Ht. in = 20.00 Bar Lap/Hook BELOW Ht. in = 20.00 Wall Weight psf = 42.0 Rebar Depth 'd' in = 2.75 Masonry Data f m psi = 1,500 Fs psi = 20,000 Solid Grouting = No Special Inspection = No Modular Ratio'n' = 25.78 Short Term Factor = 1.330 f Equiv. Solid Thick. in = 3.90 Masonry Block Type = Medium Weight # Concrete Data fc psi = i Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S ` Fr Heel: Not req'd, Mu < S " Fr Key: No key defined Page 1 Footing Strengths & Dimensions ' c = 2,500 psi Fy = 40,000 psi Ain, As % = 0.0012 Toe Width = 0.00 ft Heel Width = 3.00 Total Footing Width = ---- 3-.0-9- Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in 2nd Stem OK 0.00 Masonry 8.00 # 4 16.00 Edge 0.823 295.5 857.3 1,041.2 5.2 22.3 20.00 6.00 78.0 5.25 1,500 20,000 Yes No 25.78 1.150 7.60 /C'_ CE31325 (b Exp. 12/31 J /Z008 CIVIL OF Al IFS/ TIMOTHY S. MALLIS CIVIL ENGINEER Title: ORCO BLOCK INC. Dsgnr: � 4510 RUTILE ST. Description RIVERSIDE, CA. 92509 Scope: (951) 685-1521 I Rev 510300 User:KW-0603522,Ver51.3.22-Jurn1999.WA32 Cantilevered Retaining Wall Design (6) 1983-99 ENEftCALC Job # Date: 4:40PM, 12 DEC 07 Description DUNE PALMS T-4" RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Page 2 Summary of Overturnin 8� Resisting Forces 8� Moments y ....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 328.1 1.44 473.6 Soil Over Heel = 893.6 1.83 1,638.2 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 101.4 7.33 743.3 Soil Over Toe = SeismicLoad = Surcharge Over Toe = Stem Weight(s) - 511.7 0.29 149.6 Total = 429.5 O.T.M. = 1,216.8 Earth @ Stem Transitions = Resisting/Overturning Ratio = 2.26 Footing Weight = 450.0 1.50 675.0 Vertical Loads used for Soil Pressure = 1,950.1 Ibs Key Weight = Vert. Component = 94.8 3.00 284.4 Vertical component of active pressure used for soil pressure Total = 1,950.1 Ibs R.M.= 2,747.1 TIMOTHY S. MALLIS CIVIL ENGINEER ORCO BLOCK INC. 4510 RUTILE ST. RIVERSIDE, CA. 92509 (951) 685-1521 V Rev: 51113111) User. KW-0603522, Ver 5.1.3. 22-J-1999, Win32 L (C) 1983-99 ENERCALC Title : Dsgnr: Description Scope : Cantilevered Retaining Null Design Job # Date: 4:40PM, 12 DEC 07 Description DUNE PALMS 4'-0" RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Criteria Retained Height = 4.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 3.00 in Soil Density = 115.00 pcf Wind on Stem = 16.9 psf Desi n Suimaryg. �a Total Bearing Load = 2,366 Ibs ...resultant ecc. = 8.56 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 Toe Active Pressure = 0.0 Passive Pressure = 150.0 Water height over heel = 00 ft FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Soil Pressure @ Toe = 1,731 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,294 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 23.7 psi OK Allowable = 85.0 psi Wall Stability Ratios Overturning = 2.40 OK Sliding = 1.75 OK Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 538.9 Ibs less 100% Passive Force = - 117.2 Ibs less 100% Friction Force = - 828.2 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 : 1 Stability = 0.0 Ibs OK Footing Design Results Toe Heel Factored Pressure = 2,294 0 ps Mu': Upward = 0 0 ft Mu' : Downward = 0 0 ft Mu: Design = 0 1,841 ft-# Actual 1-Way Shear = 0.00 23.74 psi Allow 1-Way Shear = 0.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Stem Construction -, T Design height ft = Wall Material Above "Ht" _ Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Ibs = Moment.... Actual ft-# _ Moment..... Allowable ft-# _ Shear..... Actual psi = Shear..... Allowable psi = Bar Develop ABOVE Ht. in = Bar Lap/Hook BELOW Ht. in = Wall Weight psf = Rebar Depth 'd' in = Masonry Data p Stem Stem O 4. Mason 6. 32.0 Cent Page 1 Footing Strengths & Dimensions 7 _ 00 00 er fcf = 2,500 psi Fy = 40,000 psi Min" As % = 0.0012 Toe Width = 0.00 ft Heel Width = 3.25 Total Footing Width = � 1, Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in 2nd K Stem OK 0.00 ry Masonry 8.00 4 # 5 0 16.00 Edge 0.937 101.4 304.2 324.8 4.5 25.8 20.00 20.00 42"0 2.75 fm f # -# psi= 1,500 Fs psi = 20,000 Solid Grouting = No Special Inspection = No Modular Ratio'n' = 25.78 Short Term Factor = 1.330 Equiv. Solid Thick. in = 3.90 Masonry Block Type = Medium Weight Concrete Data fc psi = Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S . Fr Heel: Not req'd, Mu < S ' Fr Key: No key defined 0.890 381.4 1,083.1 1,216.7 5.8 22.3 25.00 6.00 78.0 5.25 1,500 20,000 Yes No 25.78 1.150 7.60 CE-319.25 ExP- 12131/200 8 J' VI �1 TIMOTHY S. MALLIS CIVIL ENGINEER Title: Job # ORCO BLOCK INC. Dsgnr: Date: 4.40PM, 12 DEC 07 � 4510 RUTILE ST. Description • RIVERSIDE, CA. 92509 Scope: a (951) 685-1521 N Rev, 510300 Page 2 User: KVJ- 1,22. Ver 5.1.3. 22-Jun-1999, Wn32 Cantilevered Retaining Wall Design (c) 1983-99 ENERCALC c:\documents and settingsltmallis\my documen Description DUNE PALMS 4'-0" RETAINING W/ 6' CMU WALL ON TOP LEVEL BACKFILL 80C WIND & .258W SEISMIC Summary of Overturnin 8: Resisting Forces &Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs It ft-# Ibs ft ft-# Heel Active Pressure = 437.5 1.67 729.2 Soil Over Heel = 1,188.3 1.96 2.327.2 Toe Active Pressure = 0.42 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 101.4 8.00 811.2 Soil Over Toe = SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 564.0 0.30 167.0 Total = 538.9 O.T.M. = 1,540.4 Earth @ Stem Transitions = Resisting/Overturning Ratio = 2.40 Footing Weight = 487.5 1.63 792.2 Key Weight = Vertical Loads used for Soil Pressure = 2,366.2 Ibs Vert. Component = 126.4 3.25 410.8 Vertical component of active pressure used for soil pressure Total = 2,366.2 Ibs R.M.= 3,697.1