Loading...
11-0131 (SOL)P.O. BOX 1504. 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00000131 Property Address: 47795 DANE PALMS RD APN: 60.0-020-041- - Application description: SOLAR Property Zoning: REGIONAL COMMERCIAL Application valuation: 19131 T419 4 4 Qum& Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am.licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B' Cl'0 C46 License : 910836 it Contractor: Date: 4/1 OWNER -B ER DECLARATION I hereby affirm under penalty of perik that I am;exempt from the Contractor's State License Lew for the following reason (Sec. 7031-6, Business "and Professions Code: Any city or county"that requires a permit to construct, alter, improve; demolish, or repair any structure, prior to its issuance, also requires 'the applicant .for the permit to file a signed statement that he;orrshe,is.licerwed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section.7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the%basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects.the applicant to a civil penalty, of not more than five hundred dollars,($ 600).: 1 _) 1, as ownerof the property, or myemployees with wages as.their sole compensation, will do the work, and the structureJs.not intended or offered for sale (Sec: 7044; Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves'thereon, sand who does the work himself'orherself•through his or her own^employees,., provided that the improvements,are not'imended or offered for sale. If, however,the building or improvement is sold within one year of completion, the owner -builder will have the:burden of proving that he or she did not -build or improve for the purpose of sale.). (. .) I, as owner of the property, em exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Coder The Contractors' State License Law does.not apply town owner of property who builds or improves thereon,.and who contracts for the projects with -a coritractoris) licensed pursuant to the Contractors' State License Law.): I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirrn finder penalty of:perjury that there.ina construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)• Lender's Name: Lender's Address:, LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011. INSPECTIONS (760) 777-7153 Data: 2/14/11 Owner: COACHELLA VALLEY HOUSING COALI 45701 MONROE ST 1.-G, INDIO, CA 92201 17 D q Contractor: RENOVA ENERGY CORP 75181 MEDITERRANEAN AVENUE (3F LAQUOTA PALM DESERT, CA 92211 trl�lA�ve,�C�PT (760)_568-3413 Lic. No.: 910836 WORKER'S. COMPENSATION DECLARATION I, hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a'certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code;,for the performance of,the work for which this permit is issued.. _ I have and will maintain workers' compensation insurance, as required.by Section -3700 of the Labor Code, for the.performince,of the work for which this permit is issued. My workers' compensation insurance carrier and'policy.numberare: Carrier NORGUARD INS Policy. Number REWC128450 _ I certify that, in the performance of the work for which this permit is issued, I shall.not employ any person in any manner sous to become subject to the workers' -compensation laws of California, and agree that, if I -should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall rthwith comply with tho provisions. Date:g-&-Zll Applicant: WARNING: FAILURE TO SECURE W KERS' COMPENSATIO VE GE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMI L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S.FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Applicationis, hereby made to the'Director of Building and Safety for a permit subject to the conditions and restrictions set forth, on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to,.and shall defend, indemnify:and hold harmless the City of Le Ouinta, its officers, agents and employees for any act or ornission related to the work being performed underor following issuance of this permit. 2. Any permit issued as a result of this applicationbecomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will.subject permit to cancellation. I. certify that I have read this application and state that -.the above information incorrect: 1 agree -to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter. upon the above-mentioned property for. inspection purposes. ` Date: /S- '/r Signature (Applicant or Agent): N LQPEL r Application Number . . . . . 11-00000131 Permit. . . SOLAR PERMIT Additional desc . . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . Valuation 19131 Expiration Date 8/13/11 Qty Unit Charge Per. Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 Permit . . . Additional desc . . Permit Fee . Issue Date . . . . Expiration Date . . ELEC-MISCELLANEOUS 22.50 Plan Check Fee 5.63 Valuation . . . . 0 8/13/11 Qty Unit Charge Per Extension - BASE FEE 15.00 1.00 7.50.00 EA ELEC PWR APP >1 TO <=10 7.50 --------------------------------------------------------------------------------- Special Notes and Comments 3.24k -W PV SYSTEM - (,12) 270W PANELS W/ (1)SOLECTRIA PVI- 3000 INVERTER [251SF] 2010.CALIFORNIA ELECTRICAL CODE. [BUILDING: 3100 - CARPORT: 51 February 14, 2011 10:32:41 AM AORTEGA ------------------.---------------------------------------------------------- Other Fees . . . . . . BLDG SIDS ADMIN (SB1473) 1.00 .Fee summary Charged Paid Credited Due Permit Fee Total 42.00 .00 .00 42.00 Plan Check Total 1.0.51 :00 .00 10.51 Other .Fee Total 1.00 .00 .00 1.00 Grand Total 53.51 .00 .00 53.51 Bin # City of La Qu►nta Budding 8r Safety Dbislon P.O. Box 1504, 78-495 Calle Tampico La Qainta, CA 92253 -.(760) 77770.12 Building Permit Application and Tracking Sheet Perinit # - 1�1 Project Address: 4777Y h I NE PA tM3 RA-. Owner's Nene:�oaL�j eMlla VGt �f• Co�i tl rl A. P. Number: 6000 20O y l Address: YS70 I � `on IVE! 5-f _ Sv,-�fe CT Legal Description: Contractor: Reno o, rCi1 C0 r Co r , Address: 75l g1 Me ;'Terrer',' Aw Av Ave— City, ST, Zip:._Ii (� C . c Telephone: - 6 0 — -3q-7—"3/-5'7 PmjectDesai on: 't (/ 11 t C � � So %ar �o v o17�, C City, ST, Zip: Payr., 1/e f e(_.fit. 7zz l J ► �1 f �i ii i 9 v► 6 ✓1 exT l' Telephone: 60 ,SCS- 3y13 reA&roved State Lic. # : City Lic. #: Arch., Engr.,.Designer. Address: City, ST, Zip: Telephone: Construction Type: Occupancy: Project type (circle, one): New Add'n Alter Repair Demo State Lic. #: Name of Contact Person: Sq. Ft.: #'Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: "Rasa APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sebe Pfau Check submitted Item Amount' Structural Gales. Reviewed, ready for corrections Plan Check Deposit Truss Calls. Called Contact Person Plan Check Balance Title 24 Calls. Plans picked up Construction Flood plain plan Pians resubmitted Mechanical Grading plan 2'' Review, ready for corrections/issue Eleetrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plana resubmitted Grading IN HOUSE:- ''s Review, ready forcormcdons/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Data of permit issue School Fees Total Permit Fees A141 %at,- INVERTER #12 PV ARRAY System Size = 2.819 kW (1 String of 12 modules) Qty (12) Suntech STP270-24Vd 270 watt modules 44.5 Volts / 8.20 Amps PV source #Pv0 USE -2 Qty. (1) Solectri'a PVI 3000 circuit C 12 modules in series Pv- Disconnect 3000 Watt Inverter / 240 Volts EG Typical Mounted on �Voltage 534 x 1.12 (Temp31°to 230f) [per NEC 690.7] = 598 Volts DC structure at - M readily Li T accessible V Sched 40 PVC I locationmm (2) #8 THWN-2 (2) #8 THWN-2 AWG Wire VDC(1) r #8 THWN-2 Gnd N ed Roof 0 _ cc J -box To Main- 600 Amp Multi - Metering Panel M Meter #: 1 B4SR-133149 1 Phase, 1.20/240 V (1) 20 Amp 2 pole breaker in house panel as. Solar system disconnect. Accessible o � o House Subpanel 100 Amp 240 Volt AC Buss 100 Amp Wer Ground +GEC CITY OF LA QUINTA BUILDING T. 8 SAFETY DEP APPROVED FOR CONSTRUCTION DATE BY 60o 20o q / N i0 4 cc M 2) c <0 dW a 30�� � °r° m c L6 a Y � �o E '158.20 Amps each circuit.X 1.56 = 1.2.79 Amps DC = 12 x 44.5 = 534 Volts DC �Voltage 534 x 1.12 (Temp31°to 230f) [per NEC 690.7] = 598 Volts DC M 1 (Strings) per Inverter max = LO (2) #8 THWN-2 AWG Wire Outdoor U) (1) N #8 THWN-2 Ground 0 _ cc � #8 AWG-THWN-2 de -rated to 82%(ambient temp 50° @ 90' rating[underground per NEC Table 690.31(c)]) =45.1 Amps DC Indoor - a Q 45.1 Amps x :80%(per NEC Table 310.15(13)(2)(a)= 36.08 Amps DC E N V Fused at 15 Amps each circuit located at inverter +� � C EMT C0 0 +-• C € W L1) Z_ p) -� EMT Solectria PVI 3000 DC Disconnect (D p f1` a � J (2) #10 THWN-2 inverter Integrated in Drawn By: (1) #10 THWN-2 Neutral Located next to main panel Inverter Located 8FT. From House Subpanel (1) #8 Ground M.D. Checked By: 600 VDC rated T.H. V-.IF(iseRating Date Drawn: :Z: 02/03/2011 30 Amp Revision No. 240 Volt AC Knife Switch 0 �� Disconnect = 15Amps SQUARE -D E.13 •� DU221.RB 0 WM CP 1 Disconnect )00111 6 (12 modules) Bldg #31.00 100 Amp House Panel 240 Volt --,,30 Amp AC Disconnect Lockable 240 Volts 240 H: 4,580 kWh Solectria PVI 3000 E: 4,426 kWh 3,24 kW DC 2.819 kW AC CP 14 CITY CITY OF LA QUINTA C" BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE eyd 4EEE-�� ALAR) Checked By: T.H. Date Drawn: 02/03/2011 Revision No. 0 Sheet No. S.17 Inverter #12 UU C) W cf) C.4 > 0 cr—, M D � L�,)< "LO 02 (cr) L ob CU Ell - r:L 04 M CCOD L 0, coo E— IF a) C: CU (D E LO ALAR) Checked By: T.H. Date Drawn: 02/03/2011 Revision No. 0 Sheet No. S.17 Inverter #12 W cf) Cn E "LO CU Ell - — CU 04 M L mU a) C: CU (D E LO C 'F3 M Zti (j ,0 CU a. ALAR) Checked By: T.H. Date Drawn: 02/03/2011 Revision No. 0 Sheet No. S.17 Inverter #12 Trust Suntech to Deliver Reliable. Performance Over Time World's leading manufacturer of crystallinesilicon photovoltaic,modules Unrivaled' manufacturing capacity and world class technology • Rigorous quality control meetingthe highest international standards: ISO 001:1009 and ISO 14001: 2004 Certification and standards: IEC 61.215„IEC 61730,conformltyto+CE Industry leading warranty ® . s �x ri to wa ®Copyright 2010 Suntech Power 25 yeautransferrable power output warranty: 5 year/9596;12 year/.90%,18 year/8596,25 year/8096 -' Based on nominal power Warrants 6.7%more power than the. market standard over 25 years 5 year material and workmanship warranty ®&CE A®, II Textured surface and silicon nittide.anti-reflection coating Improves light absorption for more current production Suntech's reputation is founded ommore than 1.5 gigawatts<ofhigh - performing solar modules installed_ around'the world • Please refer to Suntech Standard Module lnsfalladon Manual fordetails "Pleaserefer to, SuntEo Product Warraw for details 9a Note: mm lrnarJ Current -Voltage & Power -Voltage Curve (280-24) 9 r 3e 4, 3 I 0 Voltage M taeewW = ewww - mWhin = =Whw - =wW Temperature Characteristics Nominal Operating Cell Temperature (NOM ..................................... _......................... ............... ..... .. 45±2"C _...... _._.............._................. Temperature Coefficient of Pmax ....................... _........... .......... _..... ......... _.............. .................................. -0.47,%rC .-._.._..................... TemperatureCoeffident of Voc -0.34 %/°C Temperature Coefficient of Isc 0.045 96PC Dealer information box Specifications are subject to change wit hout-further.notification Electrical Characteristics LSIX Optlinum Operating Voltage.(Vmp) STP27"4(Vd -- 35.OV — STP275-24Nd —� 35A V Optimum Operating Cirrent(imp) 7.71A 7.84A Open -.Circuit Voltage (Voc) 44.5V 44.7 V Short- Circuit Current (Isc) 8:20 A 8.26 A Maximum Power at STC Wma4 270 W 275 W Module Efficiency 13:9% 14.2% Operating Temperature -40°Cto+85'C -40°Cto+85°C Maximum System Voltage 600 V DC 600 V DC Maximum Series Fuse Rating 20A 20A Power Tolerance 0/+5 W 0/+5W STC Irtadiance t 000 W /m', module temperature 25'(_ AWLS NGCT Maximum Power (W) I STP270.24/Vd 197W STP275424/Vd 201 W Maximum Power Voltage (V) 31.8.V 31.9V Maximum Power Current (A) 6.20 A 6,29 A Open Circuit Voltage.(Vod 40.6V 40.7 V Short Circuit Current (Isc) 6.63 A 6.68 A EMdency Reductlon (from 1000 W/m'to 200 W/m?) <4.5% <4.5% NOCT. Irradiance 800 W/m', ambient. temperature 20 °C; wind speed I m/s Mechanical Characteristics Solar Cell No. of Cells Dimensions Weight Front Glass Frame ......... .... Junction Box Output Cables Packing Configuration Polycrystalline 156 x156 mm (6 inches)' 72:(6 x 12) 1956 x 992 x,50'mm (77:0 x 39.1 x 2.0 inches) 27 kgs (59.5 lbs.) 4.0 mm (a 16 Inches) tempered glass Anodize0aluminium alloy .................................................................... _ IP67 rated H+5 RADOX* SMART cable 4.0 mm2 (0.006 inches'), symmetrical lengths (-)1100 mm (43.3 Inches) and (+) 1100 mm (43.3:inches), F4 connectors (MC4 compatible) Container 21YGP 4D'GP i 41YHC Pieces per pallet .............. I .... ...................... ........................... _............. 21 ............ .................. ............................. 21 -......... 21 ....... .................... ......... Pallets per container 6 12 24 Pieces per container 126 252 504 ;;Moil, JLECTRIA N E W A B L E S PV1 3000 PVI 4000 a breakthrough in efficiency and quality XtBT 1p © top CEC efficiency ® DC disconnect ® string combiner m quick -mount bracket a lightweight ® 10 year warranty ® powerful LCD display a latest UL174111EEE1547 a universal 2401208VAC ® positive ground option * transformer isolation o free PC software and RS232&485 parts ® detachable DC wiring box' Solectria Introduces the PVI 3000/4000/5000/5300 Inverter: exceptional quality and efficiency with more standard features. 1W INVERTER SPECIFICATIONS PVI 3000 1. PV14000 1 PVI 5000 1 PVI 5300 Input Cordinwus Power@240 VAC 208 VAC 305OW 2840W 4100W 3580W 515.OW 452OW '5575W 484OW Recommended Max. PV @240 VAC Array Power, STC Rating @208 VA 360OW 3400W 490OW 430OW 620OW 540OW 6700W 580DW PPT voltage Range 20OV-550 VDC 20OV-550 VDC . 20OV-550 VDC 20OV-550 VDC Maximum lnputVokage 600 VDC 600 VDC 600 VDC 600 VDC tike Volta98 1 235 VDC 235 VDC 235 VDC 235 VDC Maximum 1 ut Current 16 A 20 A 25 A 251A Maximum Short Circuit Current 24 A I 24A 30 A 30A Fused Inputs 3 1 4 4 4 Output ntinuous Power 4R240 VAC 208 VAC 290OW 270OW 390OW 3400W 490OW 430OW 530OW 460OW ohage Range @240 VAC 208 VAC 212-264 VAC 184228 VAC 212-264 VAC 184-228 VAC 212-264 VAC 184228 VAC 212-264 VAC 184-228 VAC Frequency 60Hz Ran a:,59.3-W.5Hz 601-1z Range: 59.3-60.51-1z 601-1z Ran e::59.3-60.5Hz 601-1z Range: 59.3-60.5Hz nuous Current 13-A 16.3 A 20.7'A 22.1 A ut Current Protection Required 20 A 25 A 30 A 30A ex; Backfeed Current 0 A O A O A O;A Factor UtlB , >99% Uti , >99% utility. >99% utility, >99% .HD <3% <3% 1 <3% <3% deny Peak @240 VAC 208 VAC 96.7 96.4 96.7 96.5 96.7 96.4 96.6 96.3 EC EMdency @240 VAC 208 VAC 96.0 95.5 96.0 95.5 96.0 96.0 96.0 95.5 General Fused PV Combiner 600 VDC Disconnect Detachable Wiring Box DC Connections AC Connection INDUSTRY LEADING FEATURES • Highest efficiency tranformer isolated inverters in the industry, 96% CEC, full linel *Fully integrated with DC disconnect, 3 or 4 fuse combiner and detachable DC wiring box. •Widest DC voltage range, 200-600 VDC. e Easy installation with low weight (47-60 lb) with quick - mount bracket feature, and, universal. 2401208 VAC operation. e High reliability, 10 year warranty and certification to latest UL1741/IEEE1547. *Free PC software and both RS232&485 communication ports. eSolrenView or Fat Spanlel Inverter -Direct Internet, and/or revenue -grade monitoring options available. Also compatible with Energy Recommerce, Drakerand others'. *Optional integrated panel assemblies with kWh meter and/or AC disconnect. SROLE EC;TRIA ENEWABLS DC Power Systems (800) 967-6917 www.dcpower-systems.com www.soiren.com Ralnprool, NEMA 3R. aterial Painted aluminum emperature Range -25°C to t55°C Convection Convection and fan assist fng 47 lb (21.4 kg) 48 lb (21.8 kg) 58.5 Ib (26.6 kg) 60 m (27.4 kg) WxH) 29.76 in x 17.76 in x 9.76'i 29.76 in x 17.76 In x9.27 In 41mm x 464mm x 176mm 41 mm x 454mm x 210mms12 to 6 AWG input end output connectlons UL1741AEEE1847JEEE1547.1, ANSI62.41.2, FCC part'15 B 10 years standard Fused PV Combiner 600 VDC Disconnect Detachable Wiring Box DC Connections AC Connection INDUSTRY LEADING FEATURES • Highest efficiency tranformer isolated inverters in the industry, 96% CEC, full linel *Fully integrated with DC disconnect, 3 or 4 fuse combiner and detachable DC wiring box. •Widest DC voltage range, 200-600 VDC. e Easy installation with low weight (47-60 lb) with quick - mount bracket feature, and, universal. 2401208 VAC operation. e High reliability, 10 year warranty and certification to latest UL1741/IEEE1547. *Free PC software and both RS232&485 communication ports. eSolrenView or Fat Spanlel Inverter -Direct Internet, and/or revenue -grade monitoring options available. Also compatible with Energy Recommerce, Drakerand others'. *Optional integrated panel assemblies with kWh meter and/or AC disconnect. SROLE EC;TRIA ENEWABLS DC Power Systems (800) 967-6917 www.dcpower-systems.com www.soiren.com Introducing Type VBII 60OVDC Enclosed Photovoltaic Disconnect Switches. The first UL Listed line of'disconnect switches specifically designed for use with three separate 60OVDC circuits. One VBII disconnect performs the function of three competitive switches. These switchesare designed for use in negative ground 60OVDCmax. photovoltaic systems which must°co.mply with Article:690�of the: NEC. Features • Available in 30-100A ratings in both fusible and non -fusible versions • Type 1 and 3R enclosures for either indoor or outdoor applications • All. switches comply with UL98 requirements. and are UL listed in file number E335018 as UL1.741 Photovoltaic Disconnect Switches • Tested per UL requirements to control three separate600VDC circuits ina single 3 pole switch • Factory'instalied ground barsupplied as standard • Door labeling required by Article 690 of the NEC is supplied as standard, • Unique enclosure design features a rolled gut front flange that prevents cuts and scrapes to conductor insulation and to the installer's hands • Metal handle with large plastic grip features a positive stop in both the ON and OFF positions • Two and 3 point mounting provisions are standard • Largetop,, bottom and side gutters facilitate wiring • Line and load Lugs accept larger conductors than required by UL to allow larger cables to be used when required to minimize voltage drop Heavy Duty Photovoltaic Disconnect Switches Answers for industry. SIEMENS Magnets A true design innovation! A very hot arc is generated by the interruption of a 600VDC circuit when under load. This damages conventional safety switch contacts and insulating material after a small number of operations unless the poles are connected in series to spread this destructive energy over at least two,sets of contacts. As illustrated above, powerful magnets have been incorporated into the line base assembly of our disconnects which are UL1741 test requirement l � I \�Con�rectsl. strategically located and specifically aligned to disperse this energy'and to very quickly extinguish the arc. The result is a line of disconnects that performs at a level far beyond that of any conventional safety switch. These switches have passed the extremely rigorous testing required by UL1741 for photovoltaic disconnects with three separate 600VDC circuits connected to a single 3 pole switch as detailed below. The test requirements for UL1741 are the same as those for Note: Disconnects are .subject to applicable de -rating factors UL98 except that the overload testing per UL1741 must be defined by Article 690 of the NEC. conducted at 20096 of the switch rating and this is reduced to 15096 for UL98. Wiring diagrams Non -Fusible disconnects Photovoltaic 0 f-) 0 + + + Arrays + + « Disconnect Switch (+) (+) (+) Output to Inverter(s) 0 0 (-) W HF36ZPV HNF361,RPV Ordering information (for use on negative ground systems) 0 a- li i I HNF363RPV I I I I I � HA161234 � A Note: All disconnects are. rated aY10,000 AIC per UL requirements when used with ; J or protected by Class K, J, or R fuses rated at 600VDC. I Accessories HP63. _ _ -. _- .;3 pole 100'A kit HR612 lip*i i I 1 HN61.2 � � I 1 l ECH5200 s 1 HR61.2. _ 30A, 600V 3.pole kit HR62 60A, 60OV 3 pole kit. HR63 100A,.600V3 pole kit, �,HN6J2 30Aneutral-kit HN623 11 60;and TOOA neutralkit" A Ila co HA161234 ki i` 1, N0;.1;NC (10A at_250V_AC_max.)- HA261234 2 NO« 2NC (I PA at.250V ACrmax); ECH5075 _ I;'Ye_(conduit size) _ ECHS100 11 V (conduit size) I_ ECHST25 1 1 Y. (conduit size) ECH5T5 l—w conduit size) JCH5200 _ - ,' 2' (conduit size) ECHS250 . 214 (conduitsize) �HP61 7j 3,pole 30A IA HP62 3 pole, 60A kit - HP63. _ _ -. _- .;3 pole 100'A kit HR612 lip*i i I 1 HN61.2 � � I 1 l ECH5200 Dimension Drawing TOP ENDWALL (outdoor only) OVISION FOR TYPE %T HUB .64 C G 27 DIA I F 45 64 9 01 1011 12 OU 1 35 AA(2) KI &-60- -27 1 i5 2 .50, 8 0 .2y 7 1:.69 7 Kn1douls 2.50 J (Mockout) 10.17 - 825 .32 (%"r only) F 5.05 C Q A oo /-BBFor 3D&IODA AA for 60A li8.35 FPN BOTTOM ENDWALL (Also. typical for top endwall for indoor switches) i- D I BB (1) CODA BB (3) 3DA AA I$ ODA M AA (2) IDDA .25 27 DIA .65 1--.75 DETAIL C Catalog number I Dimensions - Inches -".&"t Locations 1) 45 64 9 01 1011 12 OU 1 35 434 63 9:SQ 91 1.46 91 -i I H:Fj6,iPV- 16.26 9w15 17.,46- 11 1.5i iffi 14:62 1.19 _71- &-60- -27 1 i5 2 .50, 8 0 .2y 7 1:.69 7 2.50 [4110361W 11.11 6. 12.31 �76.52 7.20 1.35" 3.00 4 - 95 1.80 9" IL 1.46 .91 HNF362PV 16:2b 9;15F1-7,46, 111.58 1 13.3.6 PV 7r 410340 21.95 9.64 23.15 1 1-2.01 1.9.34 1938 1.119 j�7:00 T .98 AS 65 3.50 2.50 �2.88 �; 2. =1.46 IHF362RPV ii 16.26 13.36 IF 9.15 17.46 11.53 1 IC2 1.1 6.00 .72- -25 11.25 2.50 !1 .87 j1.69 'y 1.69 -F87 =21.95 1:1;4 -I 230. 2.88 98 2.45 85 6.64� - 'F - - - H 12.31 )01 i5 iO NF361'RPV �Lll_-" 7 -IF 1.35 -'( ;I d 3.00 1' . 1.86 91 1.462) .91 HNF363RPV 121 _95 964 23-15 12:01 79.3A 1938 1-19 7-00 350 250 2 -RA 9A 2 45 AS 1) Additional knockouts supplied near the -top in back and side surfaces of indoor Notes: enclosures are not shown. 1. Indoor enclosures'are constructed of .054 inch:thick cold rolled steel', 2) Knockout supplied on,left side only. 1 Outdoor enclosures are constructed from .054 inch thick.galvanized steel 3. Finish is ANSI #61 gray Knockout sizes (inches) and wiring bending/side gutter space -1; � Conduit -size Wire bending & side gutter space (inches) Knockout Catalog nurnbei code (inches) ifr3 1�11 ON __TA__A(_cohcentric) 3 30 .02 _�.61 -A - �­- 4.-, j - -11 jiN-F-3- 6--1P-V-, _H_43�61 kF7V' f�____ 3.02 (t ngiritia :7F5b 5, 1. 0 IHF362FV I ,HF362RPV AA 3.54 3.57 2 HNIF362PV, HNF.iC?-RP-Vl (tangential) 100 1 25 1_541 8.68 1 '5 i0o AA (tangential) 160-, -.2 -5, .5-6 -j� .0 RPIV !I FC --12.75 BB (tangential) 0 §P­V.HNF363,RPV 1.0 , 1,15, 1.50_2 60 The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of.contract. All product designations may be trademarks or product names of Siemens Ad or supplier companies whose use by third! parties,fortheir own purposes could violate the rights of the owners. Wiley Electronics LLC Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For Pro Solar Installations WEEB-PMC WEEBLUG G. Products are tested to UL 467 3M8177 UL standard for safety grounding and bonding equipment Document Number 104-0404-000008-005 Wiley Electronics LLC. 2006© — All Rights Reserved. SYSTEM OVERVIEW electrically connect spliced rails W. V..11,. VVI IV VV•VI Note: WEEBs are intended for single use only. Functionality will not be guaranteed if reused. WEE'B-PMC ASSEMBLY Wiley Electronics LLC. 20060 -,All Rights Reserved 0 Place WEEB-PMC over sliding nuts aligning clearance a hole to threaded hole Use mid clamp and fasteners to position WEEB-PMC teeth under edge of solar module Slightly lift solar module to slide -lift into position Wiley Electronics LLC. 2006© - All Rights Reserved O Use mid clamp and bolt to position WEEB-PMC Ensure WEEB-PMC teeth are properly aligned under solar modules Wiley Electronics LLC. 2006© - All Rights Reserved Wiley Electronics LLC. 2006© —All Rights Reserved WE,EB-PMC LAYOUT EVEN NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-PMC CXR=4X1 WEEB-PMC NEEDED = C X R= 4 X 1= 4 ODD NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-PMC CXR=5X1 WEEB-PMC NEEDED = [C+1] X R = [5+1] X 1 = 6 Note: When replacing a single faulty module, also remove the adjacent module which contacts the same WEEBs as the faulty module. This will ensure that there are never ungrounded modules in the array. Wiley Electronics LLC. 20060 —.All Rights Reserved Dd 0 of Foi on Assen fasten WEEBLUG ASSEMBLY Wiley Electronics LLC. 2006© — All Rights Reserved 0 Wiley Electronics LLC. 2006© -All Rights Reserved nent ground id torque bolt N -m PMC SPLICE KIT ASSEMBLY 0 c� r rL-wwv ue fasteners ft -Ib / 13.5 N -m `-WARNING—Electric Shock HazaV d No user serviceable parts inside Contact authorized servicer for assistance WARNING -Dual Power Sources Second source is photovoltaic system u Solar Discont��,ect WARNING — Electri oc'k Hazard DO NOT TO RMIINALS Terminals on b ie and Load sides may be energized in the Open Position. WARNING Panel Contains D.C. Solar Power System Disconnect May NOT De— Energize All Power Sources Too -,Electrical connomrs, compression, taps, spliceM grotmft and more Pap 1 of 1 ,COOL LAY -IN ALMU w • Manufactured horn ldgh strength 1061 •T0 aluminum alloy. • Moatro-un plated. • ORA Is UL 467 Umbd for grounding and bonding. • QBLA10 & COL -260 are UL 407 Recognised for grounding and bonding. • Lay -In teeWe. • SdIlable for use with either copper or esurMrwrn, • Pravtdea tow con%d resistance. • Ratod for 000 V ta. iL . • Seo New GBL -40B br lay4n copper lug suitoble for direct burial. tea. • UL Filo E34440JE8207 • cabins Ntrnhane link he ran Ilia au auullahAM Ph.010 4. ILSCO 09L4DBT.Iug at'taohed to PVtoad ule http:llebusinesailsoo.cam ymbapplvvWslor else+rvleVCotcmyDisplay?storoad-l0001&1angld t&c auaogld-,,, 7I1/2008 Range 8oq Bio gin N,A GA No. lCatimbpRo,Hax 481A 1 "4M10 8 7Aldsia1 M GBL -M 1 10-148TR. 114 8 7036U 8010 GBL.M Z 210`MCM8M. 114 7w 79�a�e601® Ph.010 4. ILSCO 09L4DBT.Iug at'taohed to PVtoad ule http:llebusinesailsoo.cam ymbapplvvWslor else+rvleVCotcmyDisplay?storoad-l0001&1angld t&c auaogld-,,, 7I1/2008 AWARNING All Professional Solar Products (ProSolar) are engineered and tested to withstand stated specifications (as stated on published specification sheets) when installed properly. Fail- ure to install properly may decrease the .performance. of in- stallation. 0 SAFETY All regional safety 'requirements should be followed when installing Professional Solar Products. All tools and equip- ment located on the roof should be secured to avoid falling object hazards. All equipment/tools should be properly maintained and inspected prior to use. Any exposed studs should be protectively capped to help avoid injury. This installation manual is. intended for use by professional installers with a working knowledge of construction princi- ples. • Chalk line • 3/16" carbide masonry drill bit • 3/8" masonry drill bit (for tile roof) • Cordless drill • Cordless impact wrench with 1/2" socket Rooffrov Installation Manual Date Modified: 08/13/07 APPLICATION: The RoofTrac mounting system consists of sup- port rails and top-down clamping hardware which is integrated with either a TileTrac or Fast lack attachment device. The RoofTrac mounting sys- tem can be utilized on virtually all standard con- struction residential roof -tops, mounting 4' on center, to install the majority of popular framed solar modules. Page 1 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All Information contained In this manual Is property of Professional Solar Products (PSP). TIIeTmc6 is a registered trademark for PSP and is covered under U.S. patent #5,746,029. Roan rae® and FwUaek® is a registered trademark for PSP and is covered under U:S. patent #6,360,491. Rooffraco Installation Manual Date Modified: 08/13/07 1) Utilizing the Splice Kit 2) Attaching Support rails to the TileTrac®/FastJack®' 3) Installing modules 4) Cleanup and safety Step 1: Utilizing the Splice Kit 6:�i7 'r �It ie rocomended thdtyou}pre=instaifiae3sptrce kat the ground for easler[handirng oftthe 5vp porirarls after, rnsaflmglthe�spirces. serthe iengths,agarnstthe buildiigE7yprcally� the.lnstaller on. the roof can pelt the lengths torthe goof wrthoutrarlyechanrc'W-.,quipment and handle the r f n z t17 yy.�tl IIJ7. I T ti CS�'n ft n lengths as- one unit 113 Y T »•n a. I0. 13 I 17 _1... I.AI�r ,. t..�q �1� i,.l ,.t� I�7.�1� �r1,[•^S t3jful ,''�;frri .J �d-�5a-i�11 ._4d. , �bl l - Felt Tip Pen Splice holes— mark with permanent ink pen I f V -groove drill guide Lower Support \� 1/8" Gap Turn the support rails upside down (as illustrated) so the bottom is facing up. Place the lower support over the rails to. use as a template. Center the lower support over the rails and mark along the V groove drill guide using a small felt pen. Uni-Bit® Intersections of the reference mark and extended "V" groove. Use' of tiUrnbrt� �� t'will decrease dnU {�- ;trme.to approxi- ,� r matelyAseconds s to er hole' ; Drill two holes using a 1/2"#10 UniBit®. Drill at the intersection of the reference mark and the "V" groove drill guide. Page 2of7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All information contained In this manual is property of Professional. Solar Products (PSP). TIIeTracO is a registered trademark for PSP and is covered underU:S. patent#5,746,029. RoorryacO and.Fastdack® is a.registered trademark,for PSP and is covered under U.S. peterd #6;360,491: professional so • .. -* Rooffrav Installation Manual Date Modified: 08/13/07 Insert the splice "A" into the channel and install "B" —the two 5/16" bolts / lock washers— into the lower support "C". Tighten using a 1/2" socket. Splice insert is designed to expand into the extrusion walls forcing the rails into alignment, do not over tighten. Roof Trac® support rails can now can be handled and installed as one solid rail. A q% l Insert Extrusion cket B 5/16 bolts/ �v lock washers Lower Support Splice Expansion :Feature:- ` RootTrac® splice kitpareadesignedi to hold support rails in alignment and allow for:thermal; expansion ofithwaluminum. After fastening the support rails to the attachments,,renf ve:one of the 5/1.6"'bolts::Themial expansion ofthe .aluminum-support`raiis will now°be;absorbed;im the splice connection instead pf stressing the roof attachments; .The remaining Splice kit bolt and assembly will, keep the support:rails in.perfect alignment: Page 3 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All Information contained in this manual is property of Professional Solar Products (PSP). 'TlleTrac® Is a registered trademark for PSP and is covered under U.S. pateryt45,746,029. RoofTrac® and FastJack® is.a, registered trademark for PSP and is covered under US. patent46,360,491. Rooffraco Installation Manual Date Modified: 08/13/07 Step 2: Attaching Support Rails, to TileTrac®/FasUack® T -wrench N -e TileTrac® version (FastJack version on next page) TileTrac Device Nut/Washer combo Installation of the RoofTrac® support rails to the TileTrac®. After the TileTrac® has. been installed (refer to the respective installation guide), lay the support rail (upside down) next to the attachments, step 1, as illustrated above. Mark the channel adjacent to the attachment devices. Align and mark the intersecting "V" groove drill guide on the rail and drill a 1/2" hole through the rail. After drilling the hole, place the rail over the attachment feet, install the 3/8" washer and nut and tighten using a 9/16" deep socket wrench. Your support rails are now secure and ready for installation of the modules. ttmexosapproxrmately.3�secondsap�er Page 4 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All information contained in this manual,is property of Professional Solar Products (PSP). TiieTraa® is a registered trademark for PSP and is covered under U.S. patent #5;746,029. RoofTrac® and FasWack® is a registered trademark for PSP and Is covered.under U.S. patent #6,360,491. .A Nut/Washer combo Installation of the RoofTrac® support rails to the TileTrac®. After the TileTrac® has. been installed (refer to the respective installation guide), lay the support rail (upside down) next to the attachments, step 1, as illustrated above. Mark the channel adjacent to the attachment devices. Align and mark the intersecting "V" groove drill guide on the rail and drill a 1/2" hole through the rail. After drilling the hole, place the rail over the attachment feet, install the 3/8" washer and nut and tighten using a 9/16" deep socket wrench. Your support rails are now secure and ready for installation of the modules. ttmexosapproxrmately.3�secondsap�er Page 4 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All information contained in this manual,is property of Professional Solar Products (PSP). TiieTraa® is a registered trademark for PSP and is covered under U.S. patent #5;746,029. RoofTrac® and FasWack® is a registered trademark for PSP and Is covered.under U.S. patent #6,360,491. professional SOLAR product Rafters Installation of the Roofrrac® support rails to the Fastlack®. After the FastJack® has been installed (refer to the respective installation guide), lay the support rail (upside down) next to the attachments. Mark the channel adjacent.to the attachment devices. Align and mark the intersecting "V".groove on the rail and Rooffraco Installation Manual Date Modified: 08/13/07 FastJack® Standard Flashing drill a 1/2" hole through the rail. After drilling the hole in the support rail, place the rail over the attachment feet, make any necessary final adjustments and tighten the 3/8" Bolt & Washer combination to attach the support rail to the FastJack®. Your support rails are now secure and ready for installation of the modules. Page,5 of 7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007: All information contained in,this manual is property of Professional Solar Products (PSP). TIIeTrac® is,a registered trademark for PSP and is covered under U:S. patent #5,746,029. RoolTrac® and�FasWack® is a ,registered trademark for PSP and is covered under U.S. patent #6;360,491. E professional SOLAR Rooffracial products Installation Manual Date Modified: 08/13/07 f =far cbnvenrence,, it!(5advisable tb pre-asserrrble the bolt, loctz washer and clamp into the J 3 siidrng insert prior, to bringrn tem Lu{ to the roof t r r4 ! ll -TV -Z �1 rr f �J.; yT.. . L- y i t '1l 1 I J'4"4. Fig. 2 #4 r} Fig.1 Eli- t I a - � Attachment and clamping of the solar modules to TileTrac® or Fast)ack® attachments works exactly the same. After the support rails have been fastened, you are ready to install the solar modules. There are two sets of clamps; the outside clamps (end clamp) (Fig. 1) and the inter -module clamps (Fig. 2) that install between the modules. Please note that all module end clamps are specially extruded to fit a specific brand of module as specified in the ordering guide. NOTE: Clamping hardware is not engineered or intended for use on support rail/strut other than the Professional Solar Products brand. Page 6 of 7 COPYRIGHT PROFESSIONAL SOLAR'PRODUCTS 2007: All Information contained in this manual Is property of Professional Solar Products (PSP). TIIeTrac® is a registered trademark for PSP and is covered under U.S. patent #5,746,029. RoofTrac® and Fastiack® is a registered trademark for PSP and Is covered under U.S. patent #6,360,491. Step 5: Installing Modules Rooffrar Installation Manual Date Modified: 08/13/07 Slide the two end clamps near the end of the support rail and install your end module (first). Carefully square the module to the frame and tighten the clamps using a 1/2" box wrench or drive socket. DO NOT OVER TIGHTEN, we recom- mend a maximum torque of 12. foot pounds to prevent damage to the module. After the first module is secured, slide two inter - module clamp sets onto the first module side frame. They are designed to stay in place, freeing you up to slide and align the next module into place. Repeat this procedure until all modules are in- stalled onto the support rail. Upon installation of the last module in the panel, install the module end clamp to the end of the last module. Before fully tightening the bolts, make any adjustments needed to create a square and even array. Once all modules are in the position desired, use a 5/16" Socket impact set to 12 ft. lbs to tighten the bolts on the clamps. To complete the installation, cut off any excess support rail not used with a reciprocating saw. You may want to use an extrusion blade. Page 7 of'7 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2007; AII'infonnation contained in this manual is property of Professional Solar Products (PSP). TIIsTraa® Ise registered trademark for PSP and is covered under U.S. patent #5;748,029. RoolTrac® and Fast lack® Is a registered trademark for PSP and Is covered under U.S. patent #6,380;491. Rail Placement -in Valley of Corrugated Roofing O Screw Placement(2 every 4' purlin with washer) PrOfts6lo l Solar ItaQ(2' bxfi deo) 3/16' x 1 Vr Stainkm SOeel Sor AK" Cae4 Carport Purlln S.13