10-0828 (RER)P.O. BOX 1504 T4ht 4
Qum&
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 10-00000828 Owner:
Property Address: 51645 EISENHOWER DR HANSEN DAVID
APN: 773-134-018-6 -000000- 51645 EISENHOWER DR
Application description: REMODEL. - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: COVE RESIDENTIAL
Application valuation: 188226
Contractor:
Applicant: Architect or Engineer: DAVIS RESTORATION OF
77833 PALAPAS ROAD
PALM DESERT, CA 92211
(760)360-185S
Lic. No-: 677877
LICENSED CONTRACTOR'S DECLARATION
1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B /Iraw 677877
Date:i •- $4 Contractor:
A OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does'not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ I 1 am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.)..
Lender's Name:
Lender's Address:
LQPERI.IIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 11/10/10
WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this -permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier NAT' L UNION Policy Number 4880392
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to;be-V7Urkef< compensation provisions of Section
3700 of the Labor C „ I sha h �th cply ith t se provisions.
Date: r/ 140-0 Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or c for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above inf mation is rrect. I agrP
ply with all
city and county ordinances and state laws relating to bu'Id' constru n, ereb uth entatives
of this county to enter upon the above-mentioned propert nspec
Date: -/� Signature (Applicant or Agent):
Application Number . . . . . 10-00000828
------ Structure.Information FIRE REPAIR ENTIRE RESIDENCE [ENG]
-----
Other struct info . .
. . . CODE EDITION 2007/2008
----------------------------------------------------------------------------
# BEDROOMS
3.00
Permit . . .
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
951.00
Plan Check Fee
618.15
Issue Date . . . .
Valuation . . . .
188226
Expiration Date . .
5/09./11
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
89.00 3.5000
----------------------------------------------------------------------------
THOU BLDG
100,001-500,000
311.50
.Permit. . . .
ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee
72.70
Plan Check Fee
18.18
Issue Date . . . .
Valuation . . . .
0
Expiration Date
5/09/11
Qty Unit Charge
Per
Extension
BASE
FEE ,_
15.00
1433.00 .0350
ELEC
NEW RES- 1 OR 2 FAMILY
50.16
377.00 .0200
----------------------------------------------------------------------------
ELEC
GARAGE OR NON-RESIDENTIAL
7.54
Permit
MECHANICAL
Additional desc .
Permit Fee
57.00
Plan Check Fee
14.25
Issue Date.
Valuation
0
.Expiration Date
5/09/11
Qty Unit Charge
'Per
Extension
BASE
FEE
15.00
1.00 9.0000
EA MECH
FURNACE <=100K
9.00
1.00, 4.5000
EA ^MECH
VENT INST/ DUCT ALT
4.50
1.00 9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
2.00 6.5000
EA MECH
VENT FAN
13.00
1.00 6.5000'
-----------------------------------------------------------------------------
EA MECH
EXHAUST HOOD
6-.50
Permit . . .
PLUMBING
Additional desc . .
Permit Fee . . . .
40.50
Plan Check'Fee
10.13
Issue Date . . . .
Valuation . . . .
0
LQPERAIIT
Application Number . . . . . 10-00000828
Permit . . . . . PLUMBING
Expiration Date . . 5/09/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
2.00 6.0000 EA PLB FIXTURE
12.00
1.00 .7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
:
3.00
----------
Notes and Comments
FIRE REPAIR TO ENTIRE RESIDENCE
[ENGINEERED] REPLACE ROOF TRUSSES AT 1/2
OF ROOF, ELECTRICAL REWIRE, REPLACE
MECHANICAL UNITS, INSULATE AND DRYWALL
PER BID PACKAGE/SCOPE OF WORK FROM PAUL
DAVIS RESTORATION AND ENGINEERED PLAN. -
2007/2008 CALIFORNIA BUILDINGS CODES.
November 10, 2010 3:54:48 PM AORTEGA
---------=--------------
--------------
--------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473)
8.00
ENERGY REVIEW FEE
61.82
STRONG MOTION (SMI) - RES
18.82
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
Permit Fee Total 1121.20 .00 .00
1121.20
Plan Check Total 660.71 .00 .00
660.71
Other Fee Total 88.64 .00 .00
88.64
Grand Total 1870.55 .00 .00
1870.55
LQPERn11T
�l
•.' • N. Ciochini,
P.O. Box1•
PaM Desert CA 92.1
•1 • ••:
Fax •1 4• 4•1
•a moo• by the Cr: • for' • o.� • ci
• -- and • Surveyas
August 31, 2010
The City of LaQuinta
78-495 Calle Tampico
LaQuinta, CA 92253
Req1564 Eisenhower
Gentlemen:
The design of the prefabricated wood roof trusses for the subject project as prepared
by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12,
2010, and signed by Ong, Choo Soon are in general conformance with the structural
plans prepared by Joseph N. Cicchini, P.E. for the subject project.
qsi,ncerely,
eph N. Cicchini, P.E.
QROFES, C�
y\ N. CSC
CD o. 27 ?
LU m
M
CC Exp: Za
CIVIL/,�P
RE4CEIVUt r)
By.
SEP O 1 2010
•L' • m
P Box 4206
Pahi Desert CA 92260
.1 • ..:
Fax .1 4. 4.i
August 31, 2010
The City of LaQuinta
78-495 Calle Tampico
LaQuinta, CA 92253
Re: 51564 Eisenhower
Gentlemen:
The design of the prefabricated wood roof trusses for the subject project as prepared
by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12,
2010, and signed by Ong, Choo Soon are in general conformance with the structural
plans prepared by Joseph N. Cicchini, P. E. for the subject project.
cerely,
oeph N. Cicchini, P.E.
e ()FESS/o
N N • Cl C'9l
No.35727 n
LUn
c� Exp:,
CIVI
�3110
I� SEP 0 1 2010
\ 0�
Joseph N. Ciochini,
P Box0•
Pah Desert CA 92260
•1 • 6•i
Fax • • • 1
Lica-sed by I - Boad o •' C.� • .I
•I and lLarxJ &neps
August 31, 2010
The City of LaQuinta
78-495 Calle Tampico
LaQuinta, CA 92253
Re: 51564 Eisenhower
Gentlemen:
The design of the prefabricated wood roof trusses for the subject project as prepared
by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12,
2010, and signed by Ong, Choo Soon are in general conformance with the structural
plans prepared by Joseph N. Cicchini, P.E. for the subject project.
cerely,
DIOL
J s In N. Cicchini, P.E.
RECEIVER
SEP 01 2010
e�pFESS/pN
N., C//�,c�l��
W No. 27 m
`c rn
Exp:
11./1\N-'
�� SEP 0 1 2010
Joseph 11
Box 4206
Palm Desert CA. 92260
•1 • i•i
Fax .1 �•.1
Engrem and • &xveyas
December 7, 2010
The City of LaQuinta
Department of Building and Safety
78-495 Calle Tampico
LaQuinta, CA 92253
Re: 51-645 Eisenhower Drive
Plan Check #10-0825
Gentlemen:
The following change to the approved structural plans for the subject project is
acceptable in this case:
1. Change the roof diaphragm sheathing to 15/32' A.P.A. Rated Sheathing,
Exposure 1, Oriented Strand Board, from 19/32" Plywood shown on the
approved Plans.
incerely,
G
Jo ph N. Cicchini, P.E.
/2- (a -/o
By: John W. Thompson
Rancho Mirage Office: ® (760) 834-8860
Other: ❑
lIJW`1V17 , V1J:11VL'J_:JV11VV"C71iL\.PlVL'IJ W WV I r
® 71-,780 San Jacinto Dr: Ste: E2, Rancho Mirage;
Ca. 92270 ph. (760) 834-8860 fax (760) 834-8861
Letter of Transmittal
To:
City of La Quinta Today's Date:
9-15-10
78-495 Calle Tampico City Due Date:
9-15-10
La Quinta, CA 92253 Project Address:
51-645 Eisenhower Drive
Attn:
Phillip Plan Check #:
10-825
Submittal: ® 15t
❑
4th
❑ 2nd
❑
5th
❑ 3`d
❑
Other:
We are forwarding: ® By Messenger ❑ By
Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions: Includes:
# Of Descriptions:
Copies:
Copies:
®
1 Structural Plans
❑
Revised Structural Plans
®
1 Struct. Calcs
❑
Revised Struct. Calcs
®
1 Truss Calculations w/LTR
❑
Revised Truss
❑
Soils Report
❑
Revised Soils Report
❑
Structural Comment List
❑
Approved Structural Plans
❑
Redlined Structural Plans
❑
Approved Structural Calcs
❑
Redlined Structural Calcs
❑
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
®
1 Other: Scope of Work
Comments: Structural content is approvable.
This Material Sent for:
❑ Your Files
®
Per Your Request
❑ Your Review
❑
Approval
❑ Checking
❑
At the request of:
Other: ❑
By: John W. Thompson
Rancho Mirage Office: ® (760) 834-8860
Other: ❑
3
Bin�
ID
Permit #
City of La Quinta
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
,
Project Address:
Owner's Name: A S
A. P. Number:
Address:
Legal Description:
City, ST, Zip: M— Lb d2C;
Contractor:
, ••
.--
S.f:J:.::;:•:;,,;:j•:;.::::<..jti::;:•:c•i ter:;:;;%:•
Telephone: - % "-'"t»
Address: 7 7 6 3 3
Project Description:
City, ST, Zip: Pn&m
Telephone:
State Lic. # : 6,, 7 % $ % %
City Lic. #; 3
Arch., Engr., Designer:
6S EP o CJ /'0' PC
Address:
i
City., ST, Zip:
y Z(Q
Telephone: 7
:;: ;; :;%:,:j;.<,r; ;y ;:;: i^w a" h: .. • •
``>=`' $ `w`•''>3><%' ' `' 'v
Construction Type: Occupancy:
Project a circle one): New Add'n Alter(17FDDemo
State Lic. #
Name of Contact Person:
P/ -)7O e_
Sq. Ft.: 18(1
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project Z Z
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
3
Plan Sets
Plan Check submitted 10 1p
Item
Amount
-25
Structural Calcs.
Reviewed, ready for corrections Cl
Plan Check Deposit
z
Truss Calcs.
Called Contact Person tia
Plan Check Balance.
Title 24 Calcs.
Plans picked up 9
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correctio ssu U
Electrical
Subcontactor List
Called Contact Person
Plumbing '
Grant Deed
Plans picked up
S.M.I.
UA)= rApproval
Plans resubmitted
Grading
IN HOUSE:-
'd Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
RECEIVE
3OA.
SEP 01 2010
Total Permit Fees
9-1 ,o 1,-W — MS 1,610- AFfl&
BY:
�`i�s bitp •s
514 Zro — STW MPA-VWLE
F<�'alQuest.com ® - Report
Page 1 of 2
Property Detail
Report It CoreLogic
For Property Located At
RealQuest
Professional
51645 EISENHOWER
DR, LA QUINTA CA 92253-3158
Owner Information:
Owner Name:
HANSEN DAVID A/WINTERRINGER GAY L
Mailing Address:
51645 EISENHOWER DR, LA QUINTA CA 92253-3158 H003
Phone Number:
Vesting Codes:
HW / / JT
Location Information:
Legal Description:
LOT 6 BILK 115 MB 018/079 SANTA CARMELITA AT VALE LA QUINTA NO
12
County:
RIVERSIDE, CA APN:
773-134-018
Census Tract / Block.
451.11 / 3 Alternate APN:
773-134-018
Township -Range -Sect:
Legal Book/Page: 18-79
Legal Lot: 6
Legal Block: 115
Market Area:
Neighbor Code:
Owner Transfer Information:
Recording/Sale Date:
/
Sale Price:
Document #:
Last Market Sale Information:
Recording/Sale Date:
11/02/2005 /
10/07/2005
Sale Price:
$342,000
Sale Type:
FULL
Document #:
910018
Deed Type:
GRANT DEED
Transfer Document #:
New Construction:
Title Company:
Lender:
Seller Name:
Prior Sale Information:
Subdivision:
Map Reference:
Tract #:
School District:
Munic/Township:
Deed Type:
1 st Mtg Document #:
1st Mtg Amount/Type:
1st Mtg Int. Rate/Type:
1 st Mtg Document #:
2nd Mtg Amount/Type:
2nd Mtg Int. Rate/Type:
Price Per SgFt:
Multi/Split Sale:
CHICAGO TITLE CO.
FIRST HORIZON HM LN CORP
ALEJOS ELZORA F
Prior Rec/Sale Date: 10/24/1997 /
Prior Lender:
09/26/1997
Prior Sale Price: $96,500
Prior 1 st Mtg Amt/Type:
Prior Doc Number: 386862
Prior 1st Mtg Rate/Type:
SANTA CARMELITA
AT VALE LA
QUINTA 12
/ 849-E7
DESERT SANDS
INDIO
$239,400 / CONV
6.50 / ADJ
910019
$68,400 / CONV
/ FIXED
$201.06
COUNTRYWIDE HM
LNS INC
$95,759 / FHA
/ FIX
Prior Deed Type:
GRANT DEED
Property Characteristics:
Gross Area:
2,207
Parking Type:
GARAGE/CARPORTConstruction:
Living Area:
1,701
Garage Area:
506
Heat Type:
Tot Adj Area:
1,701
Garage Capacity:
Exterior wall:
Above Grade:
Parking Spaces:
3
Porch Type:
Total Rooms:
7
Basement Area:
Patio Type:
Bedrooms:
3
Finish Bsmnt Area:
Pool:
Bath(F/H):
2 / 1
Basement Type:
Air Cond:
Year Built / Eff:
1989 /
Roof Type:
Style:
Fireplace:
Y / 1
Foundation:
SLAB
Quality:
# of Stories:
1.00
Roof Material:
TILE
Condition:
Other Improvements:
ADDITION; PORCH; FENCE
Site Information:
Zoning:
R1
Acres:
0.11
County Use:
Flood Zone:
X500
Lot Area:
4,792
State Use:
Flood Panel:
0607090005BLot
Width/Depth:
x
Site
Influence:
Flood Panel Date:
08/19/1991
Res/Comm Units:
1 /
Sewer Type:
Land Use:
SFR
Water Type:
CENTRAL
STUCCO
PORCH
PATIO
CENTRAL
CONTEMPORARY
GOOD
SINGLE FAM
RESID (R01)
NONE
TYPE UNKNOWN
http://pro.realquest.com/j sp/report.j sp?&client=&action=confirm&type=getreport&recordno... 9/2/2010
1;ealQuest.com ® - Report
Page 2 of 2
Tax Information:
Total Value: $240,000
Land Value: $84,000
Improvement Value: $156,000
Total Taxable Value: $240,000
Assessed Year: 2009
Improved W 65%
Tax Year: 2009
Property
Tax:
Tax Area:
Tax
Exemption:
$3,316.06
20016
http://pro.realquest.com/j splreport.j sp?&client=&action=confirm&type=getreport&recordno... 9/2/2010
1
APPLICATION If ADDRESS 514& eA5JW L LBy Ak
VALUATION SQ . FT.
1st FLOOR
2nd FLOOR
COVERED PATIO
GARAGE
TYPE CONST:
OCCUPANCY
A/C
FIRE SPRINKLER
# OF BEDROOM
FLOOD ZONE
# OF -UNITS
CODE EDITION
ROOF TYPE
MECHANICAL
�3
w
# VENT FANS Z
# EXHAUST HOOD Z
A/C <3 TON
A/C >3 TON
FAU <100,000 BTU Cj
FAU >100,000 BTU r
DUCT ALTERATION j
# OF FIXTURES
SEWER r
SEPTIC SYSTEM --
ROOF DRAINS
WATER HEATER y
WATER PIPING
LAWN SPRINKLER f
GAS PIPING 1-4
GAS PIPING >4
GAS METER
i
UNIT COUNTS /:GAS
TOILETS
BIDET --
SHOWERS
BATHTUBS
SINKS
BAR SINK r-
BBQ
OVEN :-
RANGE
CQO KTO P
❑RINKING FOUN
WASHER t
DRYER [
WATER HEATER
ROOF DRAINS --
FLOOR DRAINS �►
KITCHEN SINK
VEG SINK
LAUNDRY SINK --
FIREPLACE
ELECTRICAL
SQ. FT- LIV
GARAGE SQ-.
TEMP POWER
FIXTURE #
GRADING
<50 CU YDS
>50 CU YDS
CDD APPROVAL _
ENGINEER APP.
TO: V OUNG
TODAY'S DATE: I
PROJECT ADDRES
APPLICANT NAME:
SUBMITTAL:
BIN NUMBER: ❑
4
P.O. Box 1504
LA QUFNTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
❑VCA
. '.
INCLUDED HEREWITH:
BUILDING & SAFETY DEPARTMEN '
(760) 777-701
FAX (760) 777-7011
V
QQ�
l7
❑ESGIL ATTENTION:
DUE DATE:
AJ.SLII &JA..I.--.s Q
❑2ND
TRANSMITTAL
W��NS
❑REDLINED PLANS
WRUCT
❑REDLINED STRUCT
V(RUSS
❑REDLINED TRUSS
❑SOILS
❑REDLINED SOILS
[-]ENERGY
❑REVISED ENERGY
❑CORRECTION LIST
[OTHER
s5W6 4 Wo RX
113R0 ❑e 05Tm
PERMIT NUMBER:
❑REVISED PLANS
❑REVISED STRUCT
❑REVISED TRUSS
❑REVISED SOILS
❑APPROVED PLANS
❑APPROVED STRUCT
[]APPROVED TRUSS
[]APPROVED SOILS
❑CUSTOMER RESPONSES
Or#mss L n-T c k-
-BUILDING DEPARTMENT USE ONLY -
GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS []COVE CHECK (w/Application)
LOCATION ON BOARD: LEFT MIDDLE RIGHT
SENT TO: 110/ SY SV SH STRUCT/NON-STRUCT
ASSIGN NON-STRUCTURAL TO:
COMMENTS:
P.O. Box 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253�'
RESIDENTIAL PLAN CHECK
DATE: SEPTEMBER 15, 2010
STATUS: FIRST REVIEW
PLAN CHECKED BY: AJ ORTEGA&
TELEPHONE NUMBER: (760) 777-7018
4y-,Q,UA4(v
UC'�r• BU �., & SAFETY DEPARTMENT
8,20,
ON LIST (os)
(760)777-7012
FAX (760) 777-7011
ADDRESS: 51-645 EISENHOWER DRIVE
DESCRIPTION: FIRE REPAIR
APPLICANT: PAUL DAVIS RESTORATION
PLAN CHECK #: 10-0825
This submittal has been checked for compliance with the 2007 California Building, Electrical, Mechanical, and
Plumbing Codes, 2008 California Energy Code, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:
3- STRUCTURAL CALCULATIONS
3- SCOPE OF WORK
2- TRUSS CALCULATIONS
2- ENERGY DOCUMENTS
1- CORRECTION LIST
r
ti
BUILDING DEPARTMENT STAFF:
DO NOT accept any resubmittal unless ALL of the
following items are included:
1- NON-STRUCT. (REDLINED) CALCS.
1- STRUCTURAL (APPROVABLE) CALCS.
1- SCOPE OF WORK (REDLINED)
1- ENERGY DOCUMENT (REDLINED)
1- CORRECTION LIST w/responses
2- REVISED PLAN SETS
2- REVISED STRUCT. CALCS.
, REVISED TRUSS CALCS.
2- REVISED ENERGY DOCS.
1- ASSESSORS SITE/FLOOR PLAN
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not w
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number'
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List (os) Page 1 of 4
City of La Quinta ;
SECTION A - GENERAL
1) Provide the Project Address on the first sheet of Plans. Correct address throughout documents/plans.
Provide the Assessor's Parcel Number (APN) and complete legal description of Project on the first sheet of
Plans.
Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared
by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions
Code §5536. Resubmittals will not be accepted with signatures missing.
/Note on Plans: "All construction shall comply with the 2007 California Building, Electrical, Mechanical, and
Plumbing Codes, 2008 California Energy Code and the City of La Quinta Municipal Code." Remove notes
referencing other Codes.
Note on Plans: "All `or equal' substitutions must be submitted to, and approved by the'Building Official prior
to installation of the item."
SECTION B — PRECISE / SITE PLAN / ZONING
/Shwoon Site Plan the location, height, and materials for all existing and proposed walls, fences, and gates.
(LQMC §9.60.030)
SECTION C - ARCHITECTURAL
/1�
pecify the make, model number, and ICC Evaluation Report Number (or UL Listing Number) of factory -built
fireplaces and/or wood stoves. (CSC Appendix Chapter 1, § 106.1.1)
Show dimensions for hearth extension at masonry fireplace. Hearths shal [ exlend•gk.least. 16 inches from the
front of, and at least 8 inches beyond each side of, the fireplace opening. \V, lier6 the fireplace opening is 6
square feet or larger, the hearth extension shall extend at least 20 inches in front of, and at least 12 inches
beyond each side of, the fireplace opening. (CBC §2111.10)
Installation of Fireplaces, Decorative Gas Appliances and Gas Logs, if masonry or factory -built shall have the
following: Metal or Glass Doors, Combustion Air Intake, and a Flue Damper. (CEC § 150 (e) LA-C)
4j Specify exterior cement plaster application (total thickness and number of coats). (CBC §2512.1) Provide wall
construction assembly that matches what is being proposed on Energy Documents. Additional
information provided on Sheet S3.1 does not specify proposed alterations.
SECTION E — ELECTRICAL
1) Provide on the plan location and ampacity of electrical meter and all sub -panels. (CBC Appendix Chapter 1,
§106.1.1)
,}'provide at least 50 percent of the total wattage installed for kitchen illumination from high -efficacy luminaires.
A kitchen lighting worksheet shall be provided on plan detailing proposed fixture wattage, lamp type and
efficacy rating that clearly identifies compliance with CEC § 150(k)8.
Residential Plan Check Correction List Page 2 of 4
City of La Quinta
,___I-�Note on Plans: "Provide at least two 20-ampere small appliance branch circuits to serve all wall, floor, and
countertop receptacles in kitchen, pantry, breakfast room, dining room, or similar area. Such circuits shall have
no other outlets." (CEC §210.11(C)(1) and 210.52(B)(1) through 210.52(B)(3))
4) >te on Plans: "Provide at least one 20-ampere branch circuit to serve laundry appliances. Such circuit(s)
shall have no other outlets." (CEC §210.11(C)(2), 210.52(F))
5) N e on Plans: "Provide at least one 20-ampere branch circuit to serve bathroom receptacles. Such circuit(s)
shall have no other outlets." (CEC §210.11(C)(3), 210.52(D))
�/ote on Electrical Plan: "All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets
installed in dwelling unit bedrooms shall be protected by an listed arc -fault circuit interrupter, combination
type; installed to provide protection of the branch circuit."
�7 f Kitchen and Dining Room Countertop receptacles shall comply with the following (CEC §210.52(C)):
f Provide cabinetry layout and show kitchen counter receptacles per California Electrical Code.
a) Provide receptacle outlets at each wall counter so that no point along the wall line is more than 24 inches,
measured horizontally from a receptacle outlet in that space.
b) Provide at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or
greater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting
edge.
.,,&rNote on Plans: "Smoke alarms shall be 120-volt with battery back-up." (CBC §907.2.10.2)
9),,,Note on Plans: "Provide interconnection so that the activation of any smoke alarm will activate all smoke
alarms in the dwelling." (CBC §907.2.10.3)
SECTION G — ENERGY EFFICIENCY
Provide Revised, Completed and Signed form CF-lR energy compliance statement. See comments listed
below and the V review redlined documents.
2'Specify the following information from Energy Calculations at each glazed opening on Window Plan:
ffi'lla) Area of glazing (in square feet)
b) Required U-factor
c) Energy Calculation Fenestration Number
3)""A reas and orientations of glazing on Plans do not match those in Energy Calculations. Reconcile Plans and
Calculations. When requested information is provided, a comprehensive review will be performed.
4,j ully specify Water Heating Device proposed for use. Show Water Heater efficiency, tank insulation, and
ANS1 requirements on plans. Information does not match between plans and calculations.
Show all required energy efficient (High -efficacy) lighting on Electrical plan. A clear description of the high
efficacy (fluorescent) and alternate lighting (incandescent, etc.) is required. (California Energy Code § 150(k))
a) Kitchen. At least 50 percent of the total wattage must be from high -efficacy luminaires. For incandescent
luminaires, "the wattage used in calculations is the highest relamping rated wattage of the fixture.
b) Bathrooms, toilet rooms, garages, laundry rooms and utility rooms. Permanently installed luminaries
that are not high efficacy are allowed provided they are controlled by an occupant sensor(s).
Residential Plan Check Correction List Page 3 of 4
City of La Quinta
c Hung Room, dining room, bedrooms, haflways, etc. (spaces other than kitchens, bathrooms,
garages, laundry rooms and utility rooms) Permanently installed luminaries that are not high efficacy
are allowed provided they are controlled by a dimmer switch or occupant sensor(s). Closets less than 70
(square feet in area may have low -efficacy (incandescent) luminaries.
i
d) Outdoor lighting that are permanently mounted to a residential[ building or to other buildings on
the same lot. Permanently installed luminaries that are not high efficacy are allowed provided they are
controlled by a motion sensor(s) with a manual on/off switch and integral photocell.
SECTION I - STRUCTURAL
ovide two (2) complete Truss Calculations. Truss layout sheets not provided with both submittals.
Important note to Engineer of Record:
If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply
submit two copies of a few supplemental calculations.
For resubmittal, include:
One complete set of structural calculations from the previous submittal, and...
Two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written
responses should direct the plan reviewer to the appropriate revised page(s).
Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose
pages will not be assembled by the Building Department.
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for
resubmittal, this administrative item must be addressed prior to issuance of building permit.
3) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation
will be performed when Plans are complete.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 4 of 4
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
Insured: Hansen, David Cellular: (760) 413-8756
Property: 51645 Eisenhower
La Quinta, CA
Claim Rep.: Cheri Molnar
Estimator: Rod Pankratz sopw WC,
Contractor:
Company: Paul Davis Restoration
Business: 77833 Palapas rd
Palm Desert, CA 92211
Claim Number:
Policy Number:
Type of Loss:
Date Contacted: 6/3/2010
Date of Loss: 6/3/2010 Date Received: 6/3/2010
Date Inspected: 6/10/2010 Date Entered: 6/9/2010 9:24 AM
Price List: CAPP7X JUN10
Restoration/Service/Remodel
Estimate: HANSEN-FIRE-SF
This is a Preliminary Estimate for the Re -build of the fire damage to the property listed above.
The Items listed are based on the fust inspection with the Adjuster of Record where a preliminary scope was agreed upon.
The Line Items listed are Preliminary in nature and once Demolition is complete we will be better able to complete the assesment
of the damage and adjust the scope of work accordingly.
There may be some over lap in scope(example-If we can clean vrs remove and replace or if 1 have clean where we need to
replace we will adjust accordinly.
Items listed as Open may fall into this catagory or there may not be a cost yet due to unknown or additional information needed.
Some Items are marked "High grade" not knowing the actual quality of the line Item and will be adjusted once comparable like
kind and quality can be established.
Engineering may be required for truss design and submittal to the La Quinta Building and Saftey Department.
Additional Code upgrades may apply.
Once plans are approved by Building and Saftey and Collaboration with The Insurance company complete we will be able to
start the rebuild process.
Rod Pankratz
Large Loss Associate
Paul Davis Restoration & Remodeling.
•
now
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
HANSEN-FIRE-SF
Main Level
Main Level
DESCRIPTION
74. Dumpster load - Approx. 40 yards, 7-8 tons of debris s ; 3.00 EA
75. General Demolition - per hour R�., 't ' 24.00 HR
Additional labor to clean up debri from grounds, cart and dump.
76. Crane and operator - 14 ton capacity -x'65' extension boom 6.00 HR
77. Taxes, insurance, permits & fees (Bid item) 1.00 EA
78. Architectural/Drafting fees (Bid item) 1.00 EA
180. Temporary power - hookup 1.00 EA
;l 81. Panelboard_- 120/240; 100 amp, single phase (per cireuit) 1.00 EX
(Temporary power was junction ed off of existing panel and approved by assigned La Quinta building inspector. Line item _lists
this as an OPEN ITEM because of the location of the panel in conjunction with the fire and no immediate damage found. T1
f : will be determined by a licensed electrical contractor on necessity of replacing if determined that it was damaged or -- - 1
compromised by_the_fire and added as a supplemental item if needed:_-__
182. Temporary fencing - 30.00 LF
183. Warning Signs and or Cones 1.00 EA
Due to the proximity of the property to a main road, (the driveway runs directly into a main traffic area) we may need
addional signage, cones, warnings for egress into the property.
401. Temporary toilet (per month) 6.00 MO
402. Residential supervision - per hour 40.00 HR
Supervisory hrs to expidite permitting and engineering, scheduling, subcontractors, supervision and job management.
NOTES:
HANSEN-FIRE-SF
e
10/28/2010 Page:2 ,
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
b
Missing Wall:
DESCRIPTION
Garage
622.00 SF Walls
1084.86 SF Walls & Ceiling
~" 51.43 SY Flooring
' 91.75 LF Ceil. Perimeter
1
1 - 16' X 7' Opens into Exterior
Height: 8'
462.86 SF Ceiling
462.86 SF Floor
75.75 LF Floor Perimeter
Goes to Floor
1. Demolish/remove - garage/room (up to 200 sf)
2. Truss.- 4/12 slope
403. Sheathing - plywood - 1/2" CDX
3. Carpenter - General Framer - per hour
Additional labor for blocking, crossbracing, lookouts and barge rafter.
4. 5/8" drywall - hung, taped, floated, ready for paint
5. Batt insulation - 4" - R13
'6: Blown -in insulation - 14" depth -1138
`Minimum Requirements as per building energy analysis report is R30 for ceilings and R 13 for walks.
7. Seal then paint the walls and ceiling twice (3 coats)
8. Clean with pressure/chemical spray - Heavy
392. Paint concrete the floor
9. Rewire - average residence - copper wiring
10. Outlet
11. Switch
12. Fluorescent - two tube - 4'- strip- light
Fixture to meet 2008 energy requirements. Note E1.0 of FIRE DAMAGE REPAIR PIAN_ .
13. Overhead door & hardware - 16'x T- High grade
14. Paint overhead door -Large - 2 coats (per side)
15. Water beater - 50 gal - Residential grade - Gas
Water heater as per Building Energy Analysys Report,
16. Heating and cooling unit - 2 ton, 80 MBH
391. Ductwork system - hot or cold air - 1200 to 1599 SF home
Will require HERS testing and acceptance standards.
HANSEN-FIRE-SF 10/28/2010
QNTY
462.86 SF
315.00 LF
462.86 SF
24.00 HR
1084.86 SF
622.00 SF
462.86 SF
1084.86 SF
462.86 SF
462.86 SF
462.86 SF
4.00 EA
2.00 EA
4.00 EA
1.00 EA
1.00 EA
1.00 EA
1.00 EA
1.00 EA
Page: 3
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Garage
DESCRIPTION QNTY
389. Exterior door - metal - insulated - flush or panel style 1.00 EA
393. Paint door slab only - 2 coats (per side) 1.00 EA
394. Paint door or window opening - 2 coats (per side) 2.00 EA
395. Door lockset - exterior 2.00 EA
399. Deadbolt 1.00 EA
398. Steel door, Y x T- fire rated 1.00 EA
396. Door hinges - Standard grade (set of 2) 1.00 EA
Self closing hinges.
NOTES:
saw Laundry Room
126.67 SF Walls
T T 141.07 SF Walls & Ceiling
m 1.60 SY Flooring
1 15.83 LF Ceil. Perimeter
5' 5'
DESCRIPTION
18. Demolish/remove - kitchen/laundry
35. 1/2" drywall - hung, taped, floated, ready for paint
52. Seal then paint the walls and ceiling twice (3 coats)
93. Saltillo tile 12" x 12"
94. Mortar bed for file floors
95. Tiletstone sealer
Height: 8'
14.40 SF Ceiling
14.40 SF Floor
15.83 LF Floor Perimeter
QNTY
14.40 SF
141.07 SF
141.07 SF
14.40 SF
14.40 SF
14.40 SF
HANSEN-FIRE-SF 10/28/2010 Page:4
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Laundry Room
DESCRIPTION
167. Interior door - full louvered - pre -hung unit
173. Cabinet knob or pull
203. Clothes dryer vent - installed
172. Paint full louvered door slab only - 2 coats (per side)
168. () Washer/Washing Machine - Top -loading
Supplied by others
170. 0 Dryer - Gas
Supplied by others
171. Shelving - 12" -in place
NOTES:
Kitchen
� r
M
1
N
F ag s --r
T 1 t
Missing Wall: 1 - 7' 413/16" X 8'
Missing Wall: 1- 4' 7 7/16" X 8'
DESCRIPTION
19. Demolishlremove - Idtchen/laundry
HANSEN-FIRE-SF
291.80 SF Walls
407.47 SF Walls & Ceiling
12.61 SY Flooring
40.90 LF Ceil. Perimeter
Opens into FAMILY
Opens into ROOM2
QNTY
1.00 EA
2.00 EA
1.00 EA
2.00 EA
1.00 EA
1.00 EA
6.00 LF
Height: Sloped
115.68 SF Ceiling
113.53 SF Floor
33.17 LF Floor Perimeter
Goes to Floor/Ceiling
Goes to Floor/Ceiling
QNTY
113.53 SF
10/28/2010 Page:5
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
CONTOWED - Kitchen
DESCRIMON
QNTY
36. 1/2" drywall - hung, taped, floated, ready for paint
407.47 SF
Orange peal texture only
53. Seal then paint the walls and ceiling twice (3 coats)
407.47 SF
� Cabinet layout and electrical layout listed on FIRE DAMAGED RESTORATION -PLAN (E1.0) i
184. Cabinetry - lower (base) units - High grade
16.83 LF
185. Cabinetry - full height unit - High grade
3.00 LF
186. Cabinetry - upper (wall) units - High grade
13.50 LF
187. Countertop subdeck - plywood
38.00 SF
188. Ceramic tile
46.00 SF
189. Ceramic file - bullnose - 2" x 6"
27.80 LF
190. Mortar bed for ceramic tile
38.00 SF
Counter Top.
191. Sink - double - High grade
1.00 EA
192. P -trap assembly - ABS (plastic)
1.00 EA
193. Angle stop
2.00 EA
194. Plumbing fixture supply line
2.00 EA
195. Dishwasher
1.00 EA
196. Refrigerator - side by side - 16 to 22 cf - High grade
1.00 EA
197. Range - freestanding - gas - High grade
1.00 EA
410. Range hood - High grade
1.00 EA
' 198. Fluorescent light fixture - High grade
4.00 EA
Code requirements may include additional lighting. Specifications listed on ELO
96. Saltillo tile 12" x 12"
113.53 SF
97. Mortar bed for tile floors
113.53 SF
98. Tile/stone sealer
113.53 SF
199. Rewire - average residence - copper wiring
113.53 SF
200. Ground fault interrupter (GFI) outlet
1.00 EA
201. Outlet
4.00 EA
202. Switch
2.00 EA
Once the walls are opened we will be able to assess the gas lines, plumbing supply and waste lines for damage. A pressure test
will be required.
HANSEN-FIRE-SF 10/28/2010 Page:6
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
NOTES:
Family Room
Missing Wall:
1-
6' 1111/16" X 8'
Missing Wall:
1-
12' 1/8" X 8'
Missing Wall:
1-
3'3 3/16" X 8'
Missing Wall:
1-
7' 413/16" X 8'
DESCRIMON
CONTINUED - Kitchen
374.86 SF Walls
652.92 SF Walls.& Ceiling
30.49 SY Flooring
69.86 LF Ceil. Perimeter
Opens into ENTRY
Opens into ROOM2
Opens into ROOM2
Opens into KITCHEN
20. Demolish/remove - bedroom/room (up to 200 sf)
37. 1/2" drywall - hung, taped, floated, ready for paint
54. Seal then paint the walls and ceiling twice (3 coats)
99. Saltillo tile 12" x 12"
100. Mortar bed for file floors
101. Tiletstone sealer
308. French double doors - Exterior - pre -hung unit
309. Paint French door slab only - 2 coats (per side)
310. Paint door or window opening - Large - 2 coats (per side)
HANSEN-FIRE-SF
QNTY
Height: Sloped
278.06 SF Ceiling
274.43 SF Floor
39.60 LF Floor Perimeter
Goes to Floor/Ceiling
Goes to Floor/Ceiling
Goes to Floor/Ceiling
Goes to Floor/Ceiling
10/28/2010
QNTY
274.43 SF
652.92 SF
652.92 SF
274.43 SF
274.43 SF
274.43 SF
1.00 EA
2.00 EA
1.00 EA
Page: 7
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Family Room
DESCRIPTION
QNTY
X311. Light Sxbuv i 1.00 EA
F Line Item listed as Open, It was hard to determine if there are any ceiling lights. Most likely this had switched lamps.
All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0�
312. Baseboard - 2 1/4" 39.60 LF
313. Paint baseboard - two coats 39.60 LF
422. Rewire - average residence - copper wiring 274.43 SF
423. Switch 2.00 EA
424. Outlet 6.00 EA
NOTES:
,? Dining Room
b � H
289.68 SF Walls
405.80 SF Walls & Ceiling
12.78 SY Flooring
40.70 LF Ceil. Perimeter
Height: Sloped
116.12 SF Ceiling
115.06 SF Floor
25.18 LF Floor Perimeter
Missing Wall:
1-
12' 1/8" X 10'
Opens into FAMILY
Goes to Floor/Ceiling
Missing Wall:
1-
Y3 3/16" X 10'
Opens into FANULY
Goes to Floor/Ceiling
Missing Wall:
1 -
4'7 7/16" X 10'
Opens into KITCHEN
Goes to Floor/Ceiling
DESCRIPTION
21. Demolish/remove - bedroom/room (up to 200 sf)
QNTY
115.06 SF
HANSEN-FIRE-SF 10/28/2010 Page:8
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Dining Room
DESCRIPTION
QNTY
38. 1/2" drywall - hung, taped, floated, ready for paint
405.80 SF
55. Seal then paint the walls and ceiling twice (3 coats)
405.80 SF
102. Saltillo tile 12" x 12"
115.06 SF
103. Mortar bed for tile floors
115.06 SF
104. Tiletstone sealer
115.06 SF
314. Baseboard - 2 1/4"
25.18 LF
315. Paint baseboard - two coats
25.18 LF
316. Rewire - average residence - copper wiring
115.06 SF
317. Switch
2.00 EA
318. Outlet
4.00 EA
319. Hanging fight fixture - Higbgrade
1.00 EA
' All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0)�
NOTES:
HANSEN-FIRE-SF 10/28/2010 Page:9
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
Entry/Foyer
116.38 SF Walls
171.84 SF Walls & Ceiling
6.07 SY Flooring
32.67 LF Ceil. Perimeter
Height: Sloped
55.46 SF Ceiling
54.60 SF Floor
7.26 LF Floor Perimeter
Missing Wall:
1 -
9' 7 1/8" X 11'
Opens into LIVING
Goes to Floor/Ceiling
Missing Wall:
1-
2'7 1/8" X 11'
Opens into LIVING
Goes to Floor/Ceiling
Missing Wall:
1-
2' 17/8" X 11'
Opens into LIVING
Goes to Floor/Ceiling
Missing Wall:
1-
3'6" X 11'
Opens into HALL
Goes to Floor/Ceiling
Missing Wall:
1-
6' 1111/16" X 11'
Opens into FAMILY
Goes to Floor/Ceiling
F2'3"1
Subroom 1: OFFSET
Missing Wall: 1-. 3'9 3/8" X 8'
DESCRIPTION
62.90 SF Walls
70.62 SF Walls & Ceiling
0.86 SY Flooring
11.64 LF Ceil. Perimeter
Opens into ENTRY
22. Demolish/remove - bedroom/room (up to 200 sf)
39. 1/2" drywall - hung, taped, floated, ready for paint
56. Seal then paint the walls and ceiling twice (3 coats)
105. Saltillo tile 12" x 12"
106. Mortar bed for tile floors
107. Tile/stone sealer
320. Baseboard - 2 1/4"
321. Paint baseboard - two coats
322. Door chime
Height: 8'
7.72 SF Ceiling
7.72 SF Floor
7.86 LF Floor Perimeter
Goes to Floor/Ceiling
QNTY
62.32 SF
242.46 SF
242.46 SF
62.32 SF
62.32 SF
62.32 SF
15.12 LF
15.12 LF
1.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 10
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Entry/Foyer
DESCRIPTION
QNTY
C- 323.- Banging light fixture 1.00 EA
rAll replaced light fixtures to meet 2008 energy Requirements (typ.)'uote FIRE DAMAGE RESTORATION PLAN (ELOY
324. Exterior door - metal - insulated - flush or panel style
1.00 EA
325. Door lockset - exterior
1.00 EA
326. Deadbolt
1.00 EA
327. Door stop = Wall or floor mounted
1.00 EA
328. Prime & paint door slab only - exterior (per side)
1.00 EA
329. Paint door or window opening - 2 coats (per side)
1.00 EA
330. Rewire - average residence - copper wiring
62.32 SF
331. Switch
3.00 EA
NOTES:
Living Room
428.35 SF Walls
673.18 SF Walls & Ceiling
b 26.51 SY Flooring
62.44 LF Ceil. Perimeter
Height: Sloped
244.83 SF Ceiling
238.56 SF Floor
47.44 LF Floor Perimeter
Missing Wall:
1-
2' 17/8"
X 8'
Opens into ENTRY
Goes to Floor/Ceiling
Missing Wall:
1-
2' 7 1/8"
X 8'
Opens into ENTRY
Goes to Floor/Ceiling
Missing Wall:
1-
9'7 1/8"
X 8'
Opens into ENTRY
Goes to Floor/Ceiling
HANSEN-FIRE-SF 10/28/2010 Page: ll
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
QNTY
23. Demolish/remove - bedroom/room (up to 200 sf)
238.56 SF
40. 1/2" drywall - hung, taped, floated, ready for paint
673.18 SF
57. Seal then paint the walls and ceiling twice (3 coats)
673.18 SF
108. Carpet - per specs from independent carpet analysis
274.35 SF
15 % waste added for Carpet - per specs from independent carpet analysis.
109. Carpet pad - per specs from independent pad analysis
238.56 SF
.332. -Aluminum window, horiz. slider 12-23 sf (2 pane)
1.00 EA
333. Aldminum window, horiz. slider 2432 sf (2 pane) a
1.00 EA
334. Aluminum window - casement, 6-8 sf - High grade P
2.00 EA
Listed on FIRE DAMAGE REPAIR PLAN- S3.1 window schedule
335. Add on for grid (double or triple glazed windows)
60.00 SF
336. Add on for "Low E" glass
60.00 SF
337. Paint door or window opening - Large - 2 coats (per side)
2.00 EA
338. Paint door or window opening - 2 coats (per side)
2.00 EA
339. Window blind - PVC - 3.5" - 7.1 to 14 SF - High grade
2.00 EA
340. Window blind - PVC - 3.5" - up to 7 SF - High grade
2.00 EA
NOTES
FPL
T 113.88 SF Walls
`� 122.58 SF Walls & Ceiling
5�� 0.97 SY Flooring
�` s' z• -� 14.24 LF Ceil. Perimeter
1 HaG-W
DESCRIPTION
Height: 8'
8.69 SF Ceiling
8.69 SF Floor
14.24 LF Floor Perimeter
41. 1/2" drywall - hung, taped, floated, ready for paint
Drywall hearth and mantle,with detail, round corners.
247. Fireplace, zero Once, wood burning, w/ venting
Replace with like kind and quality- To meet energy standards. Listed on FIRE DAMAGE REPAIR PLAN -S3.1
HANSEN-FIRE-SF 10/28/2010
QNTY
122.58 SF
1.00 EA
Page: 12
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - FPL
DESCRIPTION QNTY
58. Seal then paint the walls and ceiling twice (3 coats) 122.58 SF
NOTES:
� r 2MA ,. 0-1 Bedroom -1
n T e 384.00 SF Walls
T 499.33 SF Walls & Ceiling
12.61 SY Flooring
- f 3P ,, 43.02 LF Ceil. Perimeter
F 3'3.4 F313o4
2'4'
DESCRIPTION
Subroom 1: CLST
195.00 SF Walls
2 13. 11 SF Walls & Ceiling
1.96 SY Flooring
22.11 LF Ceil. Perimeter
25. Demolish/remove - bedroom/room (up to 200 sf)
42. 1/2" drywall - hung, taped, floated, ready for paint
59. Seal then paint the walls and ceiling twice (3 coats)
110. Carpet - per specs from independent carpet analysis
15 g$ waste added for Carpet - per specs from independent carpet analysis.
111, Carpet pad - per specs from independent pad analysis
HANSEN-FIRE-SF
Height: Sloped
115.33 SF Ceiling
113.53 SF Floor
42.67 LF Floor Perimeter
Height: Sloped
18.11 SF Ceiling
17.67 SF Floor
21.67 LF Floor Perimeter
MIU-W
131.19 SF
712.45 SF
712.45 SF
150.87 SF
131.19 SF
10/28/2010 Page: 13
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Bedroom -1
DESCRIPTION QNTY
112. Baseboard - 2 1/4"
64.33 LF
113. Paint baseboard - two coats
64.33 LF
114. Bypass (sliding) door set - Colonist
1.00 EA
251. Paint bypass door set - slab only - 2 coats (per side)
4.00 EA
252. Cabinet knob or pull
2.00 EA
253. Interior door unit
1.00 EA
118. Door knob - interior
1.00 EA
225. Door stop - Wall or floor mounted
1.00 EA
115. Paint door slab only - 2 coats (per side)
1.00 EA
116. Paint door/window trim & jamb - 2 coats (per side)
4.00 EA
226. Window blind - PVC - 2" - 7.1 to 14 SF - High grade
1.00 EA
249. Closet shelf and rod package 9.00 LF
250. Seal & paint closet shelving - single shelf 9.00 EA
254. Clean window unit (per side) 10 - 20 SF - Heavy 1.00 EA
139. Rewire - averake residence - copper wiring131.19 SF
/Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wallis opened_up
and inspection by a certified electrical contractor is verifications of damages and repairsFwill be addressed, any code
r upgrades if needed will be add_ re_ ssed as a supplement to this estimate.
140. Ceiling fan & light 1.00 EA
All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN 04) ?
144. Outlet 4.00 EA
145. Switch
307. Smoke detector
NOTES:
1.00 EA
1.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 14
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
i Coat
Height: 8'
3? 64.00 SF Walls
4.00 SF Ceiling
1 68.00 SF Walls & Ceiling
4.00 SF Floor
ry N 0.44 SY Flooring
8.00 LF Floor Perimeter
F11 1 8,00 LF Ceil. Perimeter
DESCRIPTION
QNTY
26. Demolishlremove - bedroom/room (up to 200 sf)
4.00 SF
43. 1/2" drywall - hung; taped, floated, ready for paint
68.00 SF
60. Seal then paint the walls and ceiling twice (3 coats)
68.00 SF
228. Closet shelf and rod package
2.00 LF
229. Interior door unit
1.00 EA
245. Paint door slab only - 2 coats (per side)
1.00 EA
246. Paint door or window opening - 2 coats (per side)
1.00 EA
230. Door knob - interior
1.00 EA
231. Door stop - Wall or floor mounted
1.00 EA
232. Saltillo tile 12" x 12"
4.00 SF
233. Mortar bed for tile floors
4.00 SF
234. Tiletstone sealer
4.00 SF
243. Baseboard - 2 1/4"
8.00 LF
244. Paint baseboard - two coats
8.00 LF
NOTES:
HANSEN-FIRE-SF 10/28/2010 Page: 15
r3'2'
r
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
411• 4-i-39'
X91•-� I-3'T�
Bedroom -2
420.94 SF Walls
549.17 SF Walls & Ceiling
14.02 SY Flooring
47.36 LF Ceil. Perimeter
Subroom 1: CLST
180.00 SF Walls
198.50 SF Walls & Ceiling
2.06 SY Flooring
22.50 LF Ceil. Perimeter
Height: Sloped
128.23 SF Ceiling
126.22 SF Floor
47.00 LF Floor Perimeter
Height: 8'
18.50 SF Ceiling
18.50 SF Floor
22.50 LF Floor Perimeter
DESCRIPTION
QNTY
27. Demolish/remove - bedroom/room (up to 200 sf)
144.72 SF
44. 1/2" drywall - hung, taped, floated, ready for paint
747.67 SF
61. Seal then paint the walls and ceiling twice (3 coats)
747.67 SF
130. Carpet - per specs from independent carpet analysis
166.43 SF
15 % waste added for Carpet - per specs from independent carpet analysis.
131. Carpet pad - per specs from independent pad analysis
144.72 SF
132. Baseboard - 2 1/4"
69.50 LF
133. Paint baseboard - two coats
69.50 LF
255. Bypass (sliding) door set - Colonist
1.00 EA
257. Cabinet knob or pull
1.00 EA
256. Paint bypass door set - slab only - 2 coats (per side)
4.00 EA
134. Interior door unit
1.00 EA
135. Door knob - interior
1.00 EA
224. Door stop - Wall or floor mounted
1.00 EA
136. Paint door or window opening - 2 coats (per side)
4.00 EA
137. Paint door slab only - 2 coats (per side)
1.00 EA
138. Ceiling fan &light)
1.00 EA
All replaced light fixtures to meet 2008 energy Requirements (typ.) note -FIRE DAMAGE RESTORATION PLAN (E1.0)
141. Rewire - average residence - copper wiring _ - - - - - - --
- - -- - -- -- - - ---- ---144:72"SF
142. Outlet
4.00 EA
143. Switch
1.00 EA
HANSEN-FIRE-SF
10/28/2010 Page: 16
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
306. Smoke detector
NOTES:
4'7' -
,�
4 -5 -
"St ast G
G.
DESCRIPTION
CONTINUED - Bedroom -2
Mst Clst
T 195.27 SF Walls
230.91 SF Walls & Ceiling
1 3.96 SY Flooring
24.41 LF Ceil. Perimeter
28. Demolish/remove - bedroom/room (up to 200 sf)
45. 1/2" drywall - hung, taped, floated, ready for paint
62. Seal then paint the walls and ceiling twice (3 coats)
128. Carpet - per specs from independent carpet analysis.
15 % waste added for Carpet - per specs from independent carpet analysis.
129. Carpet pad - per specs from independent pad analysis
235. Interior door unit
239. Door knob - interior
240. Door stop - Wall or floor mounted
236. Paint door slab only - 2 coats (per side)
237. Paint door or window opening - 2 coats (per side)
238. Closet shelf and rod package
258. Seal & paint closet shelving - single shelf
1.00 EA
Height: 8'
35.63 SF Ceiling
35.63 SF Floor
24.41 LF Floor Perimeter
QNTY
35.63 SF
230.91 SF
230.91 SF
40.98 SF
35.63 SF
1.00 EA
1.00 EA
1.00 EA
1.00 EA
1.00 EA
16.00 LF
16.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 17
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Mst CIA
DESCRIPTION
QNTY
241. Baseboard - 2 1/4" 24.41 LF
242. Paint baseboard - two coats 24.41 LF
447. Light fixture 1.00 EA
AD replaced light fixtures to meet 2,008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0)
NOTES:
u Hallway
r
•s r—r r iiar
e err---ra ira.•I —
r a
Missing Wan:
DESCRIPTION
285.71 SF Walls
341.39 SF Walls & Ceiling
6.19 SY Flooring
35.71 LF Ceil. Perimeter
1- 3'6" X 8' Opens into ENTRY
29. Demolish/remove - bedroom/room (up to 200 sf)
46. 1/2" drywall - hung, taped, floated, ready for paint
63. Seal then paint the walls and ceiling twice (3 coats)
119. Saltillo file 12" x 12"
120. Mortar bed for file floors
121. Tile/stone sealer
(146. Rewire --average residence__-_copper.wiring
HANSEN-FIRE-SF
Height: 8'
55.68 SF Ceiling
55.68 SF Floor
35.71 LF Floor Perimeter
Goes to Floor/Ceiling
10/28/2010
QNTY
55.68 SF
341.39 SF
341.39 SF
55.68 SF
55.68 SF
55.68 SF
55.68 SF
Page: 18
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Hallway
DESCRIPTION
QNTY
'All fire damaged wireing in attic will be replaced, the wall outlets willbe determined after demolition.
147. Outlet
3.00 EA
148. Switch - 3 way
3.00 EA
149. Baseboard - 2 1/4"
35.71 LF
150. Paint baseboard - two coats
35.71 LF
151. Paint door slab only - 2 coats (per side)
3.00 EA
409. Paint full louvered door slab only - 2 coats (per side)
2.00 EA
152. Paint door or window opening - 2 coats (per side)
4.00 EA
153: Light fixture
2.00 EA
'All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0)7
155. Thermostat
1.00 EA
NOTES:
Bathroom
295.98 SF Walls
357.06 SF Walls & Ceiling
6.79 SY Flooring
37.00 LF Ceil. Perimeter
Height: 8'
61.08 SF Ceiling
61.08 SF Floor
37.00 LF Floor Perimeter
HANSEN-FIRE-SF 10/28/2010 Page: 19
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
Subroom 1: LINEN
74.65 SF Walls
79.40 SF Walls & Ceiling
0.53 SY Flooring
9.33 LF Ceil. Perimeter
Height: 8'
4.75 SF Ceiling
4.75 SF Floor
9.33 LF Floor Perimeter
30. Demolish/remove - bathroom (up to 50 sf)
65.83 SF
47. 1/2" drywall - hung, taped, floated, ready for paint
436.46 SF
64. Seal then paint the walls and ceiling twice (3 coats)
436.46 SF
122. Saltillo file 12" x 12"
65.83 SF
123. Mortar bed for tile floors
65.83 SF
124. Tile/stone sealer
65.83 SF
156. Interior door unit
1.00 EA
157. Paint door slab only - 2 coats (per side)
1.00 EA
158. Paint door or window opening - 2 coats (per side)
1.00 EA
159. Baseboard - 2 1/4"
46.33 LF
160. Paint baseboard - one coat
46.33 LF
205. Bathroom ventilation fan - High grade
1.00 EA
259. Vanity
5.00 LF
260. Countertop subdeck - plywood
10.00 SF
261. Mortar bed for ceramic tile
10.00 SF
262. Countertop - Tile
12.50 SF
412. Ceramic tile - bullnose - 2" x 6"
5.00 LF
263. Mirror - 1/4" plate glass
15.00 SF
264. Medicine cabinet
1.00 EA
165. Light bar - 4 lights - High grade
1.00 EA
This fixture is cleanable and may not need to be replaced and will be determined duirring electrical inspections._ If replaced
will. meet 2008 energy requirements. - -
- -
450. Rewire - average residence - copper wiring with conduit
65.83 SF
Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened up
=and inspection by a certified electrical contractor -is verifications of damages and repairs
will be addressed, any code-,,, -�
upgrades if needed will be addressed as a supplement to this estimate.
This scope of work is to clean tub/surround, sink, toilet and fixtures. Once we can determine if not salvageable we can adjust
for replacement and add as a supplement to this estimate.
266. Toilet - Detach & reset
1.00 EA
HANSEN-FiRE-SF 10/28/2010 Page: 20
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
267. Clean toilet - Heavy
268. Q Bathtub - Detach & reset
If Cleanable we will not need to remove.
273. 0 Sink - single
269. Clean tub and surround - Heavy
271. Clean shower door - Heavy
272. Clean sink and faucet - Heavy
299. Bath accessory
416. P -trap assembly - ABS (plastic)
417. Angle stop
418. Plumbing fixture supply line
NOTES:
Missing Wall:
Master Bedroom
1 - 4' 11" X 8'
CONTINUED - Bathroom
505.05 SF Walls
683.41 SF Walls & Ceiling
19.31 SY Flooring
51.32 LF Ceil. Perimeter
Opens into VANITY
QNTY
1.00 EA
1.00 EA
1.00 EA
1.00 EA
1.00 EA
1.00 EA
3.00 EA
1.00 EA
3.00 EA
3.00 EA
Height: Sloped
178.36 SF Ceiling
173.79 SF Floor
50.44 LF Floor Perimeter
Goes to Floor/Ceiling
DESCRIPTION QNTY
HANSEN-FIRE-SF 10/28/2010 Page: 21
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lie # 677877
CONTINUED - Master Bedroom
DESCRIPTION QNTY
32. Demolish/remove - bedroom/room (up to 200 sf)
173.79 SF
49. 1/2" drywall - hung, taped, floated, ready for paint
683.41 SF
66. Seal then paint the walls and ceiling twice (3 coats)
683.41 SF
210. Window blind - wood - 1 " - 14.1 to 20 SF
2.00 EA
Blinds covering Patio door and window light.
211. Carpet - per specs from independent carpet analysis
199.86 SF
15 % waste added for Carpet - per specs from independent carpet analysis.
212. Carpet pad - per specs from independent pad analysis
173.79 SF
213. Baseboard - 2 1/4"
50.44 LF
214. Paint baseboard - two coats
50.44 LF
215. Interior door unit
1.00 EA
216. Door knob - interior
1.00 EA
223. Door stop - Wall or floor mounted
1.00 EA
217. Paint door or window opening - 2 coats (per side) 2.00 EA
218. Paint door slab only - 2 coats (per side) 1.00 EA
303. Clean door - French (per side) 4.00 EA
219. Ceiling fan without light ? 1.00 EA
All replaced light fixtures'to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN -(El. 0�
220. Rewire - average residence - copper wiring 173.79 SF
,Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened up>
and inspection by a certified electrical contractor is verifications of damages and repairs will be addressed, any code-
upgrades
odeupgrades if needed will be addressed as a supplement to this estimate. A f
221. Outlet 4.00 EA
222. Switch 1.00 EA
305. Smoke detector 1.00 EA
NOTES:
HANSEN-FIRE-SF 10/28/2010 Page: 22
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
3' -�2' 6' 6"
.T 2
Q Mast lD
5 8-
� 1
DESCRIPTION
1 Master Bath
185.33 SF Walls
218.86 SF Walls & Ceiling
Cl�atss.�
3.73 SY Flooring
23.17 LF Ceil. Perimeter
Height: 8'
33.53 SF Ceiling
33.53 SF Floor
23.17 LF Floor Perimeter
QNTY
31. Demolishlremove - bedroom/room (up to 200 sf)
33.53 SF
48. 1/2" drywall - hung, taped, floated, ready for paint
218.86 SF
65. Seal then paint the walls and ceiling twice (3 coats)
218.86 SF
125. Saltillo tile 12" x 12"
33.53 SF
126. Mortar bed for tile floors
33.53 SF
127. Tile/stone sealer
33.53 SF
206. Bathroom ventilation fan - High grade
1.00 EA
'This scope of work is to clean tub/surround, sink, toilet and fixtures. Once we can determine
if not salvageable we can adjust
'for replacement and add as a supplement to this estimate.
274. () Bathtub - Detach & reset
1.00 EA
If cleanable we will not need to remove.
275. Clean tub and surround - Heavy
1.00 EA
276. Clean shower - Heavy
1.00 EA
277. Clean shower door - Heavy
1.00 EA
281. Clean toilet - Heavy
1.00 EA
280. () Toilet
1.00 EA
282. Interior door unit
1.00 EA
284. Door knob - interior
1.00 EA
285. Door stop - Wall or floor mounted
1.00 EA
283. Paint door slab only - 2 coats (per side)
1.00 EA
286. Paint door or window opening - 2 coats (per side)
1.00 EA
287. Bath accessory
2.00 EA
301. Rewire - average residence --copper wiring _
33.53 SF
_
Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened np
land_inspection by a certified electrical contractor is verifications of damages and repairs will
be addressed any code
lupgradas if needed will be addressed as a supplement to this estimate: i'
302. Ground fault interrupter (GFI) outlet
1.00 EA
420. Angle stop
1.00 EA
421. Plumbing fixture supply line
1.00 EA
HANSEN-FIRE-SF
10/28/2010 Page: 23
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Master Bath
DESCRIPTION
449. Light fixture - Detach & reset
448. Clean light fixture
NOTES:
i—s.
Missing Wall:
DESCRIPTION
Vanity Area/Room
1- 4' 11" X 8'
134.00 SF Walls
162.68 SF Walls & Ceiling
3.19 SY Flooring
16.75 LF Ceil. Perimeter
Opens into MSTRBDRM
33. Demolish/remove - bedroom/room (up to 200 sf)
50. 1/2" drywall - hung, taped, floated, ready for paint
67. Seal then paint the walls and ceiling twice (3 coats)
161. Saltillo tile 12" x 12"
162. Mortar bed for tile floors
163. Tile/stone sealer
289. Q Sink - single
290. Q Sink faucet - Bathroom
288. Clean sink and faucet
HANSEN-FIRE-SF
QNTY
1.00 EA
1.00 EA
Height: 8'
28.68 SF Ceiling
28.68 SF Floor
16.75 LF Floor Perimeter
Goes to Floor/Ceiling
10/28/2010
`tom
28.68 SF
162.68 SF
162.68 SF
28.68 SF
28.68 SF
28.68 SF
1.00 EA
1.00 EA
1.00 EA
Page: 24
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Vanity Area/Room
DESCRIPTION QNTY
298. Bath accessory
1.00 EA
291. Vanity
5.00 LF
292. Countertop subdeck - plywood
10.00 SF
293. Mortar bed for ceramic tile
10.00 SF
294. Countertop - Tile
12.50 SF
411. Ceramic tile - bullnose - 2" x 6"
5.00 LF
295. Mirror - 1/4" plate glass 15.00 SF
296. Medicine cabinet 1.00 EA
297. Light bar - 4 lights - High grade 1.00 EA
-This fixture is cleanable and may not need to be replaced and `will be determined durring electrical inspections. N replaces
will meet 2008 energy requirements and comply with current codes, _
300. Rewire -average residence - copper wiring 28.68 SF
Fire did not penetrate wall cavity and no damage has been determined to the eristing electrical, once the wall is opened p�
and inspection by a certified electrical contractor is verifications of damages and repairs will be addressed, any code ]�
upgrades if needed will be addressed as a supplement to this estimate. -
413. P -trap assembly ABS (plastic) 1.00 EA
414. Angle stop 2.00 EA
415. Plumbing fixture supply line
NOTES
6'
comer e,u
_j
Linin
5.8.
Q
122.65 SF Walls
133.98 SF Walls & Ceiling
1.26 SY Flooring
15.33 LF Ceil. Perimeter
2.00 EA
Height: 8'
11.33 SF Ceiling
11.33 SF Floor
15.33 LF Floor Perimeter
HANSEN-FIRE-SF 10/28/2010 Page: 25
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 - office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
344. 1/2" drywall - hung, taped, floated, ready for paint
345. Seal then paint the walls and ceiling twice (3 coats)
346. Bifold door set - full louvered - Double
347. Paint full louvered door slab only - 2 coats (per side)
348. Baseboard - 2 1/4"
349. Paint baseboard - two coats
350. Saltillo tile 12" x 12"
351. Mortar bed for tile floors
352. Tile/stone sealer
353. Shelving - 24" - in place
354. Seal & paint closet shelving - single shelf
NOTES:
Patio
270.00 SF Walls
515.46 SF Walls & Ceiling
27.27 SY Flooring
33.75 LF Ceil. Perimeter
QNTY
133.98 SF
133.98 SF
1.00 EA
4.00 EA
15.33 LF
15.33 LF
11.33 SF
11.33 SF
11.33 SF
20.00 LF
4.00 EA
Height: 8'
245.46 SF Ceiling
245.46 SF Floor
33.75 LF Floor Perimeter
Missing Wall: 1- 22' 10" X 8' Opens into Exterior Goes to Floor/Ceiling
Missing Wall: 1- 10' 9" X 8' Opens into Exterior Goes to Floor/Ceiling
DESCRIPTION QNTY
355. Clean soffit -wood 245.46 SF
356. Prime & paint exterior soffit - exposed rafters 245.46 SF
357. Clean with pressuretchemical spray 245.46 SF
358. Paint/finish - fence post - wood. 3.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 26
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - Patio
DESCRIPTION
NOTES:
Walkway
Missing Wall: 1- 23' 6 1/2" X 8'
Missing Wall: 1 - 5' 101/2" X 8'
267.33 SF Walls
417.06 SF Walls & Ceiling
16.64 SY Flooring
33.42 LF Ceil. Perimeter
Opens into Exterior
Opens into Exterior
QNTY
Height: 8'
149.72 SF Ceiling
149.72 SF Floor
33.42 LF Floor Perimeter
Goes to Floor/Ceiling
Goes to Floor/Ceiling
DESCRIPTION QNTY
342. Clean with pressure/chemical spray 299.45 SF
Clean soft and Walk way for sealing and or paint.
343. Seal & paint stucco 149.72 SF
NOTES:
Footprint
HANSEN-FIRE-SF 10/28/2010 Page: 27
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
70. Batt insulation - 4" - R13
Living Area
1690.00 SF Walls
3290.66 SF Walls & Ceiling
174.37 SY Flooring
184.22 LF Ceil. Perimeter
Height: Peaked
1600.66 SF Ceiling
1569.37 SF Floor
182.64 LF Floor Perimeter
69. Blown4n insulation -14" depth --R38
�'—Miinimum Requirements as per buil ' ene inal sis report is R30 for ceilin
q ' p durg rgy _ y po gs and R 13 for waDs.
174. Seal stud wall for odor control
Exterior Walls
176. Seal stud wall for odor control
Interior Walls
175. Seal attic framing (white pigmented shellac) - up to 5/12
400. Deodorize building - Ozone treatment
425. Final cleaning - construction - Residential
NOTES:
Exterior
Exterior
DESCRIPTION
QNTY
1690.00 SF
1600.66 SF
1690.00 SF
1720.00 SF
1600.66 SF
18832.46 CF
1569.37 SF
QNTY
359. Wood fence 5'- 6'- high - cedar 16.00 LF
Due -to repair fire damaged fencing slats only, (maximum of 30'), and discussion with City of Laquinta building reveiwer no
Cseparate permit is required, just need to include on plan.
refer to FIRE DAMAGED REPAIR -PLAN.,S3.1--
360. Seal & paint - wood fence/gate 360.00 SF
HANSEN-FIRE-SF 10/28/2010 Page: 28
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
NOTES
L�
DESCRIPTION
CONTINUED - Exterior
East Elevation
220.00 SF Walls
220.00 SF Long Wall
21.54 LF Ceil. Perimeter
Subroom 1: Entry
209.00 SF Walls
209.00 SF Long Wall
20.62 LF Ceil. Perimeter
QNTY
Formula Elevation 20'x 9'x 4'
20.00 LF Floor Perimeter
220.00 SF Short Wall
Formula Elevation 19'x 9'x 4'
19.00 LF Floor Perimeter
209.00 SF Short Wall
QNTY
80. Metal lath & stucco _ — _ - --. - --- — _ - _ _ _ _ _ _ - - ---.267.00 SF
Stuccoreplacement include gable ends minus doors and windows, All wall surface of this elevation is listed to be replaced due
l to the removal of stucco to replace heat damaged insulation backer -REPLACE AS WAS WITH 1" foam backer, screen, and 1
L5/8" of stucco to meet NIINIIMIUM OF 7/8" stucco as listed on FIRE DAMAGE REPAIR PLAN- S3.2 - - - —J
x-83. Prime &paint door slab only - exterior (per side) — - 2.00 EA
369. Paint door or window opening - 2 coats (per side) 1.00 EA
85. Rigid foam insulation board - 1 " 267.00 SF
86. Seal & paint stucco 429.00 SF
88. Stucco repair around doors, windows, etc - 1st floor
50.00 LF
HANSEN-FIRE-SF 10/28/2010 Page: 29
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTIlVUED - East Elevation
DESCRIPTION
QNTY
89. Exterior light fixture 3.00 EA
(All replaced light fixtui-es to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION P--LAN-(E1:0))
91. Attic vent - gable end - vinyl - Large 2.00 EA
430. Prime & paint exterior soffit - exposed rafters 186.00 SF
431. Prime & paint exterior fascia - wood, 4"- 6" wide 93.00 LF
NOTES:
(�l
DESCRIPTION
South Elevation
396.00 SF Walls
396.00 SF Long Wall
44.00 LF Ceil. Perimeter
Subroom 1: Back Patio
207.00 SF Walls
207.00 SF Long Wall
23.00 LF Ceil. Perimeter
362. Paint French door slab only - 2 coats (per side)
368. Paint door or window opening -.2 coats (per side)
Formula Elevation 44'x 9' x 0"
44.00 LF Floor Perimeter
396.00 SF Short Wall
Formula Elevation 23'x 9'x 0"
23.00 LF Floor Perimeter
207.00 SF Short Wall
QNTY
2.00 EA
1.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 30
Paul Davis Restoration & Remodeling
1 77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTMUED - South Elevation
DESCRIPTION
429. Clean stucco
QNTY
301.50 SF
452. Metal lath & stucco 301.50 SF
Stucco replacement includes south wall of garage and kitchen exterior. elevation -REPLACE AS WAS WITH 1"foam backer,
screen, and 5/8" of stucco to meet MINEM UM OF 7/8" stucco as listed on FIRE DAMAGE REPAIR PLAN- S3.2 = 1
364. Seal & paint stucco - ' - - 603.00 SF
366. Exterior light fixture _ 3.00 EA
All replaced light fixtures to meet 2008energyRequirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1:0)j
432. Prime & paint exterior fascia - wood, 4"- 6" wide 72.00 LF
433. Prime & paint exterior soffit - exposed rafters
NOTES:
West Elevation
446.42 SF Walls
446.42 SF Long Wall
41.36 LF Ceil. Perimeter
DESCRIPTION
374. Paint French door slab only - 2 coats (per side)
375. Paint door or window opening - Large - 2 coats (per side)
427. Clean stucco
377. -Seal & paint stucco -
378. Stucco repair around doors, -windows, ONLY - lit door
426. Attic vent - gable end - vinyl - Large
144.00 SF
Formula Elevation 40' 7" x 9'x 4'
40.58 LF Floor Perimeter
446.42 SF Short Wall
QNTY
2.00 EA
1.00 EA
446.42 SF
446.42 SF
20.00 LF
1.00 EA
HANSEN-FIRE-SF 10/28/2010 Page: 31
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
® 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - West Elevation
DESCRIPTION
434. Prime & paint exterior soffit - exposed rafters
435. Prime & paint exterior fascia - wood, 4"- 6" wide
NOTES:
North Elevation
414.00 SF Walls
414.00 SF Long Wall
46.00 LF Ceil. Perimeter
Subroom 1: Garage
180.00 SF Walls
180.00 SF Long Wall
20.00 LF Ceil. Perimeter
DESCRIPTION
381. Prime & paint door slab only exterior (per side)
382. Paint door or window opening - 2 coats (per side)
428. Clean stucco
384::Sea18c_paint, stucco _
385: Stucco repair around.doors, windows,ONLY -1st Hoor�
-- - — --- U
HANSEN-FIRE-SF
88.00 SF
44.00 LF
Formula Elevation 46' x 9' x 0"
46.00 LF Floor Perimeter
414.00 SF Short Wall
Formula Elevation 20'x 9' x 0"
20.00 LF Floor Perimeter
180.00 SF Short Wall
2.00 EA
1.00 EA
594.00 SF
594.00 SF
20.00 LF
10/28/2010 Page: 32
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
CONTINUED - North Elevation
DESCRIPTION
388. Prime & paint exterior fascia - wood, 4"- 6" wide
436. Prime & paint exterior soffit - exposed rafters
NOTES:
Roof
Roof
DESCRIPTION
QNTY
72.00 LF
144.00 SF
N=
72. Q Tile roofing - Concrete - "S" or flat file
2.00 SQ
`REMOVE AND REPLACE BROKEN TILES ONLY
71. Tile roofing - Concrete - "S" or flat tile
16.13 SQ
REMOVE AND RESET, It is our attempt tpre place only the broken tiles and re -move and reset existing salvageable tiles and
weave in new tiles to match, install appropriate felt paper.—
If we cannot match the existing tiles, then we will need to replace all tiles:
407. Roofing felt - 30 lb.
30.00 SQ
'Replace felt as needed.
405. Q Ridge cap - the roofing
70.00 LF
408. Hip & ridge nailer board for tile roofing - wood
70.00 LF
406. Clean with pressure/chemical spray
2600.00 SF
Power wash roofing material prior to re -installing.
404. Truss - 4/12 slope
260.00 LF
Trusses over Garage.
443. Carpenter - General Framer - per hour
20.00 HR
Additional labor to cut out and remove trusses and sheeting, remove gable end and hip trines, set up, clean top plate and
prep for new trusses.
177. Framing hurricane to
30.00 EA
179. Sheathing - plywood - 1/2" CDX
900.00 SF
Roof over Residence.
73. Truss - 4/12 slope
200.00 LF
HANSEN-FIRE-SF
10/28/2010 Page: 33
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
1314D 760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
DESCRIPTION
440. Sheathing - plywood - 1/2" CDX
441. Carpenter - General Framer - per hour
442. Framing hurricane tie
444. Tile roofing - Concrete - "S" or flat tile
446. Adjustments
NOTES:
Grand Total Areas:
10,595.37 SF Walls
4,400.26 SF Floor
2,072.42 SF Long Wall
4,400.26 Floor Area
3,799.42 Exterior Wall Area
2,935.97 Surface Area
69.83 Total Ridge Length
CONTINUED- Roof
4,454.33 SF Ceiling
488.92 SY Flooring
2,072.42 SF Short Wall
4,629.17 Total Area
447.67 Exterior Perimeter of
Walls
29.36 Number of Squares
17.34 Total Hip Length
QNTY
616.00 SF
20.00 HR
18.00 EA
20.00 SQ
1.00 EA
15,049.70 SF Walls and Ceiling
1,174.53 LFF1oorPerimeter
1,295.95 LF Ceil. Perimeter
8,522.95 Interior Wall Area
300.98 Total Perimeter Length
HANSEN-FIRE-SF 10/28/2010 Page: 34
Main Level
16'2'
1
in
Me(n Level
HANSEN-FIRE-SF 10/28/2010 Page: 35
Footprint
Footprint
HANSEN-FIRE-SF 10/28/2010 Page: 36
I
�- In 3' t' IIT
G & a3x S 622'6•&
b
m
OC
(D
Roof
Paul Davis Restoration & Remodeling
77-833 Palapas Road
Palm Desert, CA 92211
760.360.1855 — office
Tax ID: 33-0576487
Lic # 677877
Sketch Roof Annotations
Face
Square Feet
Number of Squares
Slope - Rise / 12
Fl
1,114.99
11.15
4.00
F2
374.04
3.74
4.00
F4
1,008.68
10.09
4.00
F5
269.96
2.70
4.33
F6
78.84
0.79
4.00
F7
89.46
0.89
4.00
ted Total: 2,935.97 29.36
m
HANSEN-FIRE-SF 10/28/2010 Page: 38
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Fire Damage Repair -Hanson Residence
51-645 Eisenhower
La Quinta, CA 92253
Project Designer:
Paul Davis Restoration
77-833 Paladas Rd.
Palm Desert, CA 92211
(760) 360-1185
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATEiwBY
& Lao.=. IRM -06 ------
Job Number:
Date:
10/15/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
• authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
5.1 by EnergySoft User Number.-
L.
r:
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Fire Damage Repair -Hanson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration 11011512010
Date
Project Address
51-645 Eisenhower La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,569
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic R-30 1,569 Altered
Wall Wood Framed R-13 1,433 Altered
Door Opaque Door None 20 Altered
Slab Unheated Slab -on -Grade None 1,569 Perim = 196' Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (N) 32.0 0.550 0.55 none none Bug Screen Existing
Right (N) 24.0 0.550 0.55 none none Bug Screen Altered
Front (E) 70.1 0.550 0.55 none none Bug Screen Altered
Left (S) 16.0 0.550 0.55 10.0 none Bug Screen Altered
Left (S) 20.0 0.550 0.55 none none Bug Screen Altered
Left (S) 50.7 0.550 0.55 none none Bug Screen Existing
Rear (149 40.2 0.550 0.55 none none Bug Screen Altered
Rear (tM 8.0 0.550 0.55 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Altered
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC Altered Ducted Ducted Attic, Ceiling Ins, vented 4.2 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Gas 50 0.58 All Pipes Ins Altered
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2010-10-15708:45:58 ID:
Page 3 of 16
LJ
0
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Fire Damage Repair -Hanson Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family m Existing+ Addition/Alteration
Date
11011512010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Split System includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct
Condenser.
The HVAC System HVAC Altered incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2010-10-15T08:45:58 ID: Page 4 of 16
•
•
•
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Fire Damage Repair -Hanson Residence
❑ Multi Family m Existing+ Addition/Alteration
1101151201C
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 18.01 5.95 12.06
Space Cooling 110.70 105.07 5.63
Fans 22.35 26.17 -3.82
Domestic Hot Water 18.29 18.29 0.00
Pumps 0.00 0.00 0.00
Totals 169.35 155.48 13.87
Percent Better Than Standard: 8.2%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 340 70
Fuel Available at Site: Natural Gas (S) 517 87
Raised Floor Area: 0 (147 340 48
Slab on Grade Area: 1,569 (N) 517 56
Average Ceiling Height: 10.0 Roof 1,569 0
Fenestration Average U -Factor: 0.55 TOTAL: 261
Average SHGC: 0.55 Fenestration/CFA Ratio: 16.6%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
10/15/2010
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Paul Davis Restoration
Address 77-833 Pa/adas Rd. Name Rod
City/State/Zip Palm Desert, CA 92211 Phone (760) 360-1185 Signed License # Date
knemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Pa e 5 of 16
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Fire Damage Repair -Hanson Residence
Building Type IZI Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
0/15/201
OPAQUE SURFACE DETAILS
Surface IU-
Type I Area
Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,569
0.032 R-30
0 0 Altered 4.2.1-A8 E=4.2.1 -A2 Fire Restoration
Wall
461
0.102 R-13
0 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration
Wall
250
0.102 R-13
90 90 Altered 4.3.1-A3 E=4.3. 1 -A1 Fire Restoration
Door
20
1.450 None
90 90 Altered 4.5.1-A1 E=4.5.1 -A1 Fire Restoration
Wall
430
0.102 R-13
180 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration
Wall
292
0.102 R-13
270 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration
Slab
1,569
0.730 None
0 180 Existing 4.4.7-A1 Fire Restoration
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status Glazing Type Location/Comments
1
Window
16.0 0.550 Default
0.55 Default
0 Existing Double Non -Metal Tint Fire Restoration
2
Window
16.0 0.550 Default
0.55 Default
0 Existing Double Non -Metal Tint Fire Restoration
3
Window
24.0 0.550 Default
0.55 Default
0 Altered Double Vinyl Tint Fire Restoration
4
Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
5
Window
10.0 0.550 Default
0.55 Default
90 Altered Double Vinyl Tint Fire Restoration
6
Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
7
Window
30.0 0.550 Default
0.55 Default
90 Altered Double Vinyl Tint Fire Restoration
8
Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
9
Window
10.0 0.550 Default
0.55 Default
90 Altered Double Vinyl Tint Fire Restoration
10
Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
11
Window
20.1 0.550 Default
0.55 Default
90 Altered Double Vinyl Tint Fire Restoration
12
Existing
0. 5501 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
13
Window
16.0 0.550 Default
0.55 Default
180 Altered Double Vinyl Tint Fire Restoration
14
Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
15
JWndow
16.0 0.550 Default
0.55 Default
180 Altered Double Vinyl Tint Fire Restoration
16
1 Existing
0.550 Default
0.55 Default
Double Non -Metal Tint pre -altered for above
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt REA Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
6.7 6.0
10.0 0.1 10.0 10.0
14
Bug Screen
0.76
6.7 6.0
10.0 0.1 10.0 10.0
15
JBug Screen
0.76
.
16
Bug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number. 6712 RunCode: 2010-10-15T08:45:58 ID: Page 6 of 16
All
•
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Fire Damage Repair -Hanson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
0/15/201
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
U -Factor SHGC Azm Status Glazing Type Location/Comments
17 Window 4.0
0.550 Default 0.55 Default 180 Altered Double Vinyl Tint Fire Restoration
18 Existing
0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above
19 Window 10.5
0.550 Default 0.55 Default 180 Existing Double Non -Metal Tint Fire Restoration
20 Window 40.2
0.550 Default 0.55 Default 180 Existing Double Non -Metal Tint Fire Restoration
21 Window 40.2
0.550 Default 0.55 Default 270 Altered Double Vinyl Tint Fire Restoration
22 Existing
0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above
23 Window 8.0
0.550 Default 0.55 Default 270 Existing Double Non -Metal Tint Fire Restoration
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window Ove hanq Left Fin Ri ht Fin
SHGC H t Wd Len HqL LEA REA Dist Len H t Dist Len H t
17 Bug Screen
0.76
18 Bug Screen
0.76
19 Bug Screen
0.76
20 Bug Screen
0.76
21 Bug Screen
0.76
22 Bug Screen
0.76
23 Bug Screen
0.76
EnergyPro 5.1 by EnergySoft
User Number- 6712 RunCode: 2010-10-15T08:45:58 ID: Page 7 of 16
•
•
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Fire Damage Repair Hanson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
11011512010
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq Altered Removed Volume Year Built
HVAC Altered Fire Restoration
1,569
15,690 1960
Totals 01 1,5691 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC Altered 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
Altered
pre -altered for above Central Furnace
75% AFUE Split Air Conditioner 8.9 SEER Setback
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC Altered Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ New
pre -altered for above Ducted
Ducted Attic, Ceiling Ins, vented 8.0
❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
All Pipes Ins
40,000
50
0.58
n/a
n/a
Altered
Standard Gas 50 gal or Le
1
Small Gas
pre -altered for Above 1
40,000
50
0.58 1
n/a
n/a
MULTI -FAMILY WATER
HEATING DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
E
E
T
w
Hot Water Piping Length
(ft)o
c
Q —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
7QtyHP
Plenum Outside
Buried
❑
❑
❑
❑
❑
❑
❑
❑
EnemyPro 5.1 by EnemySoft User Number 6712
RunCode: 2010-10-15T08:45:58 ID:Pa
e 8 of 16
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
ire Damage Repair -Hanson Residence
Date
11011512010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water'heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulatedper Standards Table 150-B.
§1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunli ht moisture, equipment maintenance, and wind.
§1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Page 9 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
ire Damage Repair -Hanson Residence
11011512010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Li_qhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10.15708:45:58 ID: Page 10 of 16
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
ire Damage Repair -Hanson Residence
10/15/2010
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor. '
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
Q1 50(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Page 11 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ire Damage Repair -Hanson Residence
Date
10/15/2010
System Name
HVAC Altered
Floor Area
1,569
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,378
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
25,453
1,909 540
26,864
Total Output Btuh 71,000
0
Output Btuh/s ft 45.3
2,158
1,909
Cooling System
0
0
Output perSystem 41,500
0
0 0
0
Total Output (Btuh) 41,500
2,480
1,909
-2,480
Total Output (Tons) 3.5
2,158
1,909
Total Output (Btuh/s ft) 26.4
Total Output s ft/Ton 453.7
32,249
28,201
Air System
CFM perSystem
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
1,400
Split System 32,649
Total Adjusted System Output 32,649
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
3,943 71,000
3,943 71,000
Aug 3 PM Jan 1 AM
Airflow cfm/s ft 0.89
Airflow cfm/Ton 404.8
Outside Air % 0.0%
Air cfm/s ft 0.00
kHEATOutside
: values above given at ARI conditions
INGSYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of HeatingPeak
26 F
-�
Outside Air
0 cfm
69 OF
69 OF 116 OF 118 OF
f (d aJ ►
Supply Fan
Heating Coil 117 OF
1,400 cfm
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
79/64°F
79/65°F 58/56°F 59/57°F
Cooling Coil Supply Fan 61 / 57 OF
1,400 cfm
46.9% ROOM In
78/64°F
EnergyPro 5,1 by EnergySoR
User Number.' 6712 RunCode: 2010-10-15708:45:58 ID:
Page 12 of 16
•
•
ROOM HEATING PEAK LOADS
Project Name
Fire Damage Repair -Hanson Residence
Date
10/15/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Fire Restoration
Floor Area 1,569.0 ft'
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value AT °F Btu/hr
0.0320 X 44 = 2,209
0.1020 X 44 = 6,431
0.5500 X 44 = 2,195
0.5500 X 44 = 4,121
1.4500 X 44 = 1,282
0.7300 X 44 = 6,296
`X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
another room Page Total 22,534
10.00 X 0.354 /60] X 44 = 4,330
Height ACH AT
R-30 Roof
1,569.0
R-13 Wall
1,432.9
Double Non -Metal Tint
90.7
Double Vinyl Tint
170.3
Wood Door
20.1
Slab -On -Grade
Perim = 196.0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,569 X
Area
TOTAL HOURLY HEAT LOSS FOR ROOM 26,864
EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2010-10-15T08:45:58 ID: Page 14 of 16
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Fire Damage Repair -Hanson Residence 1 10/15/2010
ROOM INFORMATION DESIGN CONDITIONS
Room Name Fire Restoration Outdoor Dry Bulb Temperature 112 OF
Floor Area 1, 569.0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF
ODaaue Surfaces
R-30 Roof
R-13 Wall
R-13 Wall
Wood Door
R-13 Wall
R-13 Wall
Orientation
(N)
(E)
(E)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,569.0
0.0320
56.0
461.0
0.1020
23.0
249.8
0.1020
33.0
20.1
1.4500
33.0
430.31
0.1020
26.0
291.8
0.1020
33.0
0.0
31.4
30.0
64.1
0.0
31.4
10.0
64.1
0.0
31.4
20.1
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
Window Existing
Window Existing
Window Altered
Window Altered
Window Altered
Window Altered
Window Altered
Window Altered
Window Altered
OrIontation
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(S)
(S)
Btu/hr
2, 812
1,082
841
141
j 7,8191
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
31.4
16.0
31.4
0.0
31.4
16.0
31.4
0.0
31.4
24.0
31.4
0.0
31.4
10.0
64.1
0.0
31.4
30.0
64.1
0.0
31.4
10.0
64.1
0.0
31.4
20.1
64.1
16.0
31.4
0.0
31.5
0.0
31.4
16.01
31.5
Page Total
Btu/hr
503
503
754
641
1,922
641
1,288
503
7
Gain
5
4.0
Occupants
X
230
Btuh/occ.
Btu/hr-
c 920
t
1.0
Dwelling Unit
X
1,600
Btu
1,600
Infiltration: 1.064 X 0.87 X 97.15 X 34 =
Air Sensible CFM ELA AT
HEAT GAIN FOR
Latent Gain Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.87 X 97.15 X 0.00276 = 1,109
Air Sensible CFM ELA AW
01 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Fire Damage Repair -Hanson Residence
1 10/15/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Fire Restoration
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,569.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 78 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area GLF
Btu/hr
Window Altered (S) 0.0 X 31.4 +
4.0 X
31.5 =
126
Window Existing (S) 0.0 X 31.4 +
10.5 X
31.5 =
331
Window Existing (S) 0.0 X 31.4 +
40.2 X
31.5 =
1,268
Window Altered (lM 0.0 X 31.4 +
40.2 X
64.1 =
2,575
Window Existing (lam 0.0 X 31.4 +
8.0 X
64.1 =
513
X +
X
-
X +
X
-
X +
X
-
X +1
X
-
Page Total
4,813
Internal Gain
Btu/hr
Occu ants 4.0 Occupants X 230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.87 X 97.15 X 34 =
3,044
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
25,453
Latent Gain
Btu/hr
Occupants 4.0 Occupants X 200
Btuh/occ.
=
800
Infiltration: 4,771 X 0.87 X 97.15 X 0.00276 =
1,109
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN,FOR ROOM
1,909
EneivvPro 5.1 by EnemySoft User Number: 6712 RunCode. 2010-10-15T08:45:58 ID:
Pae 16 of 16