Loading...
10-0828 (RER)P.O. BOX 1504 T4ht 4 Qum& 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00000828 Owner: Property Address: 51645 EISENHOWER DR HANSEN DAVID APN: 773-134-018-6 -000000- 51645 EISENHOWER DR Application description: REMODEL. - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: COVE RESIDENTIAL Application valuation: 188226 Contractor: Applicant: Architect or Engineer: DAVIS RESTORATION OF 77833 PALAPAS ROAD PALM DESERT, CA 92211 (760)360-185S Lic. No-: 677877 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B /Iraw 677877 Date:i •- $4 Contractor: A OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does'not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).. Lender's Name: Lender's Address: LQPERI.IIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/10/10 WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this -permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NAT' L UNION Policy Number 4880392 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to;be-V7Urkef< compensation provisions of Section 3700 of the Labor C „ I sha h �th cply ith t se provisions. Date: r/ 140-0 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or c for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above inf mation is rrect. I agrP ply with all city and county ordinances and state laws relating to bu'Id' constru n, ereb uth entatives of this county to enter upon the above-mentioned propert nspec Date: -/� Signature (Applicant or Agent): Application Number . . . . . 10-00000828 ------ Structure.Information FIRE REPAIR ENTIRE RESIDENCE [ENG] ----- Other struct info . . . . . CODE EDITION 2007/2008 ---------------------------------------------------------------------------- # BEDROOMS 3.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 951.00 Plan Check Fee 618.15 Issue Date . . . . Valuation . . . . 188226 Expiration Date . . 5/09./11 Qty Unit Charge Per Extension BASE FEE 639.50 89.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 311.50 .Permit. . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee 72.70 Plan Check Fee 18.18 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/09/11 Qty Unit Charge Per Extension BASE FEE ,_ 15.00 1433.00 .0350 ELEC NEW RES- 1 OR 2 FAMILY 50.16 377.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 7.54 Permit MECHANICAL Additional desc . Permit Fee 57.00 Plan Check Fee 14.25 Issue Date. Valuation 0 .Expiration Date 5/09/11 Qty Unit Charge 'Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00, 4.5000 EA ^MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000' ----------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6-.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 40.50 Plan Check'Fee 10.13 Issue Date . . . . Valuation . . . . 0 LQPERAIIT Application Number . . . . . 10-00000828 Permit . . . . . PLUMBING Expiration Date . . 5/09/11 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 1.00 .7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS : 3.00 ---------- Notes and Comments FIRE REPAIR TO ENTIRE RESIDENCE [ENGINEERED] REPLACE ROOF TRUSSES AT 1/2 OF ROOF, ELECTRICAL REWIRE, REPLACE MECHANICAL UNITS, INSULATE AND DRYWALL PER BID PACKAGE/SCOPE OF WORK FROM PAUL DAVIS RESTORATION AND ENGINEERED PLAN. - 2007/2008 CALIFORNIA BUILDINGS CODES. November 10, 2010 3:54:48 PM AORTEGA ---------=-------------- -------------- -------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 8.00 ENERGY REVIEW FEE 61.82 STRONG MOTION (SMI) - RES 18.82 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 1121.20 .00 .00 1121.20 Plan Check Total 660.71 .00 .00 660.71 Other Fee Total 88.64 .00 .00 88.64 Grand Total 1870.55 .00 .00 1870.55 LQPERn11T �l •.' • N. Ciochini, P.O. Box1• PaM Desert CA 92.1 •1 • ••: Fax •1 4• 4•1 •a moo• by the Cr: • for' • o.� • ci • -- and • Surveyas August 31, 2010 The City of LaQuinta 78-495 Calle Tampico LaQuinta, CA 92253 Req1564 Eisenhower Gentlemen: The design of the prefabricated wood roof trusses for the subject project as prepared by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12, 2010, and signed by Ong, Choo Soon are in general conformance with the structural plans prepared by Joseph N. Cicchini, P.E. for the subject project. qsi,ncerely, eph N. Cicchini, P.E. QROFES, C� y\ N. CSC CD o. 27 ? LU m M CC Exp: Za CIVIL/,�P RE4CEIVUt r) By. SEP O 1 2010 •L' • m P Box 4206 Pahi Desert CA 92260 .1 • ..: Fax .1 4. 4.i August 31, 2010 The City of LaQuinta 78-495 Calle Tampico LaQuinta, CA 92253 Re: 51564 Eisenhower Gentlemen: The design of the prefabricated wood roof trusses for the subject project as prepared by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12, 2010, and signed by Ong, Choo Soon are in general conformance with the structural plans prepared by Joseph N. Cicchini, P. E. for the subject project. cerely, oeph N. Cicchini, P.E. e ()FESS/o N N • Cl C'9l No.35727 n LUn c� Exp:, CIVI �31­10 I� SEP 0 1 2010 \ 0� Joseph N. Ciochini, P Box0• Pah Desert CA 92260 •1 • 6•i Fax • • • 1 Lica-sed by I - Boad o •' C.� • .I •I and lLarxJ &neps August 31, 2010 The City of LaQuinta 78-495 Calle Tampico LaQuinta, CA 92253 Re: 51564 Eisenhower Gentlemen: The design of the prefabricated wood roof trusses for the subject project as prepared by MiTek Industries, Inc. sheets R32032243 thru R32032252, dated August 12, 2010, and signed by Ong, Choo Soon are in general conformance with the structural plans prepared by Joseph N. Cicchini, P.E. for the subject project. cerely, DIOL J s In N. Cicchini, P.E. RECEIVER SEP 01 2010 e�pFESS/pN N., C//�,c�l�� W No. 27 m `c rn Exp: 11./1\N-' �� SEP 0 1 2010 Joseph 11 Box 4206 Palm Desert CA. 92260 •1 • i•i Fax .1 �•.1 Engrem and • &xveyas December 7, 2010 The City of LaQuinta Department of Building and Safety 78-495 Calle Tampico LaQuinta, CA 92253 Re: 51-645 Eisenhower Drive Plan Check #10-0825 Gentlemen: The following change to the approved structural plans for the subject project is acceptable in this case: 1. Change the roof diaphragm sheathing to 15/32' A.P.A. Rated Sheathing, Exposure 1, Oriented Strand Board, from 19/32" Plywood shown on the approved Plans. incerely, G Jo ph N. Cicchini, P.E. /2- (a -/o By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ lIJW`1V17 , V1J:11VL'J_:JV11VV"C71iL\.PlVL'IJ W WV I r ® 71-,780 San Jacinto Dr: Ste: E2, Rancho Mirage; Ca. 92270 ph. (760) 834-8860 fax (760) 834-8861 Letter of Transmittal To: City of La Quinta Today's Date: 9-15-10 78-495 Calle Tampico City Due Date: 9-15-10 La Quinta, CA 92253 Project Address: 51-645 Eisenhower Drive Attn: Phillip Plan Check #: 10-825 Submittal: ® 15t ❑ 4th ❑ 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ® 1 Structural Plans ❑ Revised Structural Plans ® 1 Struct. Calcs ❑ Revised Struct. Calcs ® 1 Truss Calculations w/LTR ❑ Revised Truss ❑ Soils Report ❑ Revised Soils Report ❑ Structural Comment List ❑ Approved Structural Plans ❑ Redlined Structural Plans ❑ Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ® 1 Other: Scope of Work Comments: Structural content is approvable. This Material Sent for: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ 3 Bin� ID Permit # City of La Quinta Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet , Project Address: Owner's Name: A S A. P. Number: Address: Legal Description: City, ST, Zip: M— Lb d2C; Contractor: , •• .-- S.f:J:.::;:•:;,,;:j•:;.::::<..jti::;:•:c•i ter:;:;;%:• Telephone: - % "-'"t» Address: 7 7 6 3 3 Project Description: City, ST, Zip: Pn&m Telephone: State Lic. # : 6,, 7 % $ % % City Lic. #; 3 Arch., Engr., Designer: 6S EP o CJ /'0' PC Address: i City., ST, Zip: y Z(Q Telephone: 7 :;: ;; :;%:,:j;.<,r; ;y ;:;: i^w a" h: .. • • ``>=`' $ `w`•''>3><%' ' `' 'v Construction Type: Occupancy: Project a circle one): New Add'n Alter(17FDDemo State Lic. # Name of Contact Person: P/ -)7O e_ Sq. Ft.: 18(1 # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project Z Z APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Recd TRACKING PERMIT FEES 3 Plan Sets Plan Check submitted 10 1p Item Amount -25 Structural Calcs. Reviewed, ready for corrections Cl Plan Check Deposit z Truss Calcs. Called Contact Person tia Plan Check Balance. Title 24 Calcs. Plans picked up 9 Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for correctio ssu U Electrical Subcontactor List Called Contact Person Plumbing ' Grant Deed Plans picked up S.M.I. UA)= rApproval Plans resubmitted Grading IN HOUSE:- 'd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees RECEIVE 3OA. SEP 01 2010 Total Permit Fees 9-1 ,o 1,-W — MS 1,610- AFfl& BY: �`i�s bitp •s 514 Zro — STW MPA-VWLE F<�'alQuest.com ® - Report Page 1 of 2 Property Detail Report It CoreLogic For Property Located At RealQuest Professional 51645 EISENHOWER DR, LA QUINTA CA 92253-3158 Owner Information: Owner Name: HANSEN DAVID A/WINTERRINGER GAY L Mailing Address: 51645 EISENHOWER DR, LA QUINTA CA 92253-3158 H003 Phone Number: Vesting Codes: HW / / JT Location Information: Legal Description: LOT 6 BILK 115 MB 018/079 SANTA CARMELITA AT VALE LA QUINTA NO 12 County: RIVERSIDE, CA APN: 773-134-018 Census Tract / Block. 451.11 / 3 Alternate APN: 773-134-018 Township -Range -Sect: Legal Book/Page: 18-79 Legal Lot: 6 Legal Block: 115 Market Area: Neighbor Code: Owner Transfer Information: Recording/Sale Date: / Sale Price: Document #: Last Market Sale Information: Recording/Sale Date: 11/02/2005 / 10/07/2005 Sale Price: $342,000 Sale Type: FULL Document #: 910018 Deed Type: GRANT DEED Transfer Document #: New Construction: Title Company: Lender: Seller Name: Prior Sale Information: Subdivision: Map Reference: Tract #: School District: Munic/Township: Deed Type: 1 st Mtg Document #: 1st Mtg Amount/Type: 1st Mtg Int. Rate/Type: 1 st Mtg Document #: 2nd Mtg Amount/Type: 2nd Mtg Int. Rate/Type: Price Per SgFt: Multi/Split Sale: CHICAGO TITLE CO. FIRST HORIZON HM LN CORP ALEJOS ELZORA F Prior Rec/Sale Date: 10/24/1997 / Prior Lender: 09/26/1997 Prior Sale Price: $96,500 Prior 1 st Mtg Amt/Type: Prior Doc Number: 386862 Prior 1st Mtg Rate/Type: SANTA CARMELITA AT VALE LA QUINTA 12 / 849-E7 DESERT SANDS INDIO $239,400 / CONV 6.50 / ADJ 910019 $68,400 / CONV / FIXED $201.06 COUNTRYWIDE HM LNS INC $95,759 / FHA / FIX Prior Deed Type: GRANT DEED Property Characteristics: Gross Area: 2,207 Parking Type: GARAGE/CARPORTConstruction: Living Area: 1,701 Garage Area: 506 Heat Type: Tot Adj Area: 1,701 Garage Capacity: Exterior wall: Above Grade: Parking Spaces: 3 Porch Type: Total Rooms: 7 Basement Area: Patio Type: Bedrooms: 3 Finish Bsmnt Area: Pool: Bath(F/H): 2 / 1 Basement Type: Air Cond: Year Built / Eff: 1989 / Roof Type: Style: Fireplace: Y / 1 Foundation: SLAB Quality: # of Stories: 1.00 Roof Material: TILE Condition: Other Improvements: ADDITION; PORCH; FENCE Site Information: Zoning: R1 Acres: 0.11 County Use: Flood Zone: X500 Lot Area: 4,792 State Use: Flood Panel: 0607090005BLot Width/Depth: x Site Influence: Flood Panel Date: 08/19/1991 Res/Comm Units: 1 / Sewer Type: Land Use: SFR Water Type: CENTRAL STUCCO PORCH PATIO CENTRAL CONTEMPORARY GOOD SINGLE FAM RESID (R01) NONE TYPE UNKNOWN http://pro.realquest.com/j sp/report.j sp?&client=&action=confirm&type=getreport&recordno... 9/2/2010 1;ealQuest.com ® - Report Page 2 of 2 Tax Information: Total Value: $240,000 Land Value: $84,000 Improvement Value: $156,000 Total Taxable Value: $240,000 Assessed Year: 2009 Improved W 65% Tax Year: 2009 Property Tax: Tax Area: Tax Exemption: $3,316.06 20016 http://pro.realquest.com/j splreport.j sp?&client=&action=confirm&type=getreport&recordno... 9/2/2010 1 APPLICATION If ADDRESS 514& eA5JW L LBy Ak VALUATION SQ . FT. 1st FLOOR 2nd FLOOR COVERED PATIO GARAGE TYPE CONST: OCCUPANCY A/C FIRE SPRINKLER # OF BEDROOM FLOOD ZONE # OF -UNITS CODE EDITION ROOF TYPE MECHANICAL �3 w # VENT FANS Z # EXHAUST HOOD Z A/C <3 TON A/C >3 TON FAU <100,000 BTU Cj FAU >100,000 BTU r DUCT ALTERATION j # OF FIXTURES SEWER r SEPTIC SYSTEM -- ROOF DRAINS WATER HEATER y WATER PIPING LAWN SPRINKLER f GAS PIPING 1-4 GAS PIPING >4 GAS METER i UNIT COUNTS /:GAS TOILETS BIDET -- SHOWERS BATHTUBS SINKS BAR SINK r- BBQ OVEN :- RANGE CQO KTO P ❑RINKING FOUN WASHER t DRYER [ WATER HEATER ROOF DRAINS -- FLOOR DRAINS �► KITCHEN SINK VEG SINK LAUNDRY SINK -- FIREPLACE ELECTRICAL SQ. FT- LIV GARAGE SQ-. TEMP POWER FIXTURE # GRADING <50 CU YDS >50 CU YDS CDD APPROVAL _ ENGINEER APP. TO: V OUNG TODAY'S DATE: I PROJECT ADDRES APPLICANT NAME: SUBMITTAL: BIN NUMBER: ❑ 4 P.O. Box 1504 LA QUFNTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ❑VCA . '. INCLUDED HEREWITH: BUILDING & SAFETY DEPARTMEN ' (760) 777-701 FAX (760) 777-7011 V QQ� l7 ❑ESGIL ATTENTION: DUE DATE: AJ.SLII &JA..I.--.s Q ❑2ND TRANSMITTAL W��NS ❑REDLINED PLANS WRUCT ❑REDLINED STRUCT V(RUSS ❑REDLINED TRUSS ❑SOILS ❑REDLINED SOILS [-]ENERGY ❑REVISED ENERGY ❑CORRECTION LIST [OTHER s5W6 4 Wo RX 113R0 ❑e 05Tm PERMIT NUMBER: ❑REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS ❑APPROVED STRUCT []APPROVED TRUSS []APPROVED SOILS ❑CUSTOMER RESPONSES Or#mss L n-T c k- -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS []COVE CHECK (w/Application) LOCATION ON BOARD: LEFT MIDDLE RIGHT SENT TO: 110/ SY SV SH STRUCT/NON-STRUCT ASSIGN NON-STRUCTURAL TO: COMMENTS: P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253�' RESIDENTIAL PLAN CHECK DATE: SEPTEMBER 15, 2010 STATUS: FIRST REVIEW PLAN CHECKED BY: AJ ORTEGA& TELEPHONE NUMBER: (760) 777-7018 4y-,Q,UA4(v UC'�r• BU �., & SAFETY DEPARTMENT 8,20, ON LIST (os) (760)777-7012 FAX (760) 777-7011 ADDRESS: 51-645 EISENHOWER DRIVE DESCRIPTION: FIRE REPAIR APPLICANT: PAUL DAVIS RESTORATION PLAN CHECK #: 10-0825 This submittal has been checked for compliance with the 2007 California Building, Electrical, Mechanical, and Plumbing Codes, 2008 California Energy Code, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 3- STRUCTURAL CALCULATIONS 3- SCOPE OF WORK 2- TRUSS CALCULATIONS 2- ENERGY DOCUMENTS 1- CORRECTION LIST r ti BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 1- NON-STRUCT. (REDLINED) CALCS. 1- STRUCTURAL (APPROVABLE) CALCS. 1- SCOPE OF WORK (REDLINED) 1- ENERGY DOCUMENT (REDLINED) 1- CORRECTION LIST w/responses 2- REVISED PLAN SETS 2- REVISED STRUCT. CALCS. , REVISED TRUSS CALCS. 2- REVISED ENERGY DOCS. 1- ASSESSORS SITE/FLOOR PLAN INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not w acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number' and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (os) Page 1 of 4 City of La Quinta ; SECTION A - GENERAL 1) Provide the Project Address on the first sheet of Plans. Correct address throughout documents/plans. Provide the Assessor's Parcel Number (APN) and complete legal description of Project on the first sheet of Plans. Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536. Resubmittals will not be accepted with signatures missing. /Note on Plans: "All construction shall comply with the 2007 California Building, Electrical, Mechanical, and Plumbing Codes, 2008 California Energy Code and the City of La Quinta Municipal Code." Remove notes referencing other Codes. Note on Plans: "All `or equal' substitutions must be submitted to, and approved by the'Building Official prior to installation of the item." SECTION B — PRECISE / SITE PLAN / ZONING /Shwoon Site Plan the location, height, and materials for all existing and proposed walls, fences, and gates. (LQMC §9.60.030) SECTION C - ARCHITECTURAL /1� pecify the make, model number, and ICC Evaluation Report Number (or UL Listing Number) of factory -built fireplaces and/or wood stoves. (CSC Appendix Chapter 1, § 106.1.1) Show dimensions for hearth extension at masonry fireplace. Hearths shal [ exlend•gk.least. 16 inches from the front of, and at least 8 inches beyond each side of, the fireplace opening. \V, lier6 the fireplace opening is 6 square feet or larger, the hearth extension shall extend at least 20 inches in front of, and at least 12 inches beyond each side of, the fireplace opening. (CBC §2111.10) Installation of Fireplaces, Decorative Gas Appliances and Gas Logs, if masonry or factory -built shall have the following: Metal or Glass Doors, Combustion Air Intake, and a Flue Damper. (CEC § 150 (e) LA-C) 4j Specify exterior cement plaster application (total thickness and number of coats). (CBC §2512.1) Provide wall construction assembly that matches what is being proposed on Energy Documents. Additional information provided on Sheet S3.1 does not specify proposed alterations. SECTION E — ELECTRICAL 1) Provide on the plan location and ampacity of electrical meter and all sub -panels. (CBC Appendix Chapter 1, §106.1.1) ,}'provide at least 50 percent of the total wattage installed for kitchen illumination from high -efficacy luminaires. A kitchen lighting worksheet shall be provided on plan detailing proposed fixture wattage, lamp type and efficacy rating that clearly identifies compliance with CEC § 150(k)8. Residential Plan Check Correction List Page 2 of 4 City of La Quinta ,___I-�Note on Plans: "Provide at least two 20-ampere small appliance branch circuits to serve all wall, floor, and countertop receptacles in kitchen, pantry, breakfast room, dining room, or similar area. Such circuits shall have no other outlets." (CEC §210.11(C)(1) and 210.52(B)(1) through 210.52(B)(3)) 4) >te on Plans: "Provide at least one 20-ampere branch circuit to serve laundry appliances. Such circuit(s) shall have no other outlets." (CEC §210.11(C)(2), 210.52(F)) 5) N e on Plans: "Provide at least one 20-ampere branch circuit to serve bathroom receptacles. Such circuit(s) shall have no other outlets." (CEC §210.11(C)(3), 210.52(D)) �/ote on Electrical Plan: "All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit bedrooms shall be protected by an listed arc -fault circuit interrupter, combination type; installed to provide protection of the branch circuit." �7 f Kitchen and Dining Room Countertop receptacles shall comply with the following (CEC §210.52(C)): f Provide cabinetry layout and show kitchen counter receptacles per California Electrical Code. a) Provide receptacle outlets at each wall counter so that no point along the wall line is more than 24 inches, measured horizontally from a receptacle outlet in that space. b) Provide at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or greater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting edge. .,,&rNote on Plans: "Smoke alarms shall be 120-volt with battery back-up." (CBC §907.2.10.2) 9),,,Note on Plans: "Provide interconnection so that the activation of any smoke alarm will activate all smoke alarms in the dwelling." (CBC §907.2.10.3) SECTION G — ENERGY EFFICIENCY Provide Revised, Completed and Signed form CF-lR energy compliance statement. See comments listed below and the V review redlined documents. 2'Specify the following information from Energy Calculations at each glazed opening on Window Plan: ffi'lla) Area of glazing (in square feet) b) Required U-factor c) Energy Calculation Fenestration Number 3)""A reas and orientations of glazing on Plans do not match those in Energy Calculations. Reconcile Plans and Calculations. When requested information is provided, a comprehensive review will be performed. 4,j ully specify Water Heating Device proposed for use. Show Water Heater efficiency, tank insulation, and ANS1 requirements on plans. Information does not match between plans and calculations. Show all required energy efficient (High -efficacy) lighting on Electrical plan. A clear description of the high efficacy (fluorescent) and alternate lighting (incandescent, etc.) is required. (California Energy Code § 150(k)) a) Kitchen. At least 50 percent of the total wattage must be from high -efficacy luminaires. For incandescent luminaires, "the wattage used in calculations is the highest relamping rated wattage of the fixture. b) Bathrooms, toilet rooms, garages, laundry rooms and utility rooms. Permanently installed luminaries that are not high efficacy are allowed provided they are controlled by an occupant sensor(s). Residential Plan Check Correction List Page 3 of 4 City of La Quinta c Hung Room, dining room, bedrooms, haflways, etc. (spaces other than kitchens, bathrooms, garages, laundry rooms and utility rooms) Permanently installed luminaries that are not high efficacy are allowed provided they are controlled by a dimmer switch or occupant sensor(s). Closets less than 70 (square feet in area may have low -efficacy (incandescent) luminaries. i d) Outdoor lighting that are permanently mounted to a residential[ building or to other buildings on the same lot. Permanently installed luminaries that are not high efficacy are allowed provided they are controlled by a motion sensor(s) with a manual on/off switch and integral photocell. SECTION I - STRUCTURAL ovide two (2) complete Truss Calculations. Truss layout sheets not provided with both submittals. Important note to Engineer of Record: If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include: One complete set of structural calculations from the previous submittal, and... Two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. 3) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be performed when Plans are complete. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 4 of 4 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 Insured: Hansen, David Cellular: (760) 413-8756 Property: 51645 Eisenhower La Quinta, CA Claim Rep.: Cheri Molnar Estimator: Rod Pankratz sopw WC, Contractor: Company: Paul Davis Restoration Business: 77833 Palapas rd Palm Desert, CA 92211 Claim Number: Policy Number: Type of Loss: Date Contacted: 6/3/2010 Date of Loss: 6/3/2010 Date Received: 6/3/2010 Date Inspected: 6/10/2010 Date Entered: 6/9/2010 9:24 AM Price List: CAPP7X JUN10 Restoration/Service/Remodel Estimate: HANSEN-FIRE-SF This is a Preliminary Estimate for the Re -build of the fire damage to the property listed above. The Items listed are based on the fust inspection with the Adjuster of Record where a preliminary scope was agreed upon. The Line Items listed are Preliminary in nature and once Demolition is complete we will be better able to complete the assesment of the damage and adjust the scope of work accordingly. There may be some over lap in scope(example-If we can clean vrs remove and replace or if 1 have clean where we need to replace we will adjust accordinly. Items listed as Open may fall into this catagory or there may not be a cost yet due to unknown or additional information needed. Some Items are marked "High grade" not knowing the actual quality of the line Item and will be adjusted once comparable like kind and quality can be established. Engineering may be required for truss design and submittal to the La Quinta Building and Saftey Department. Additional Code upgrades may apply. Once plans are approved by Building and Saftey and Collaboration with The Insurance company complete we will be able to start the rebuild process. Rod Pankratz Large Loss Associate Paul Davis Restoration & Remodeling. • now Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 HANSEN-FIRE-SF Main Level Main Level DESCRIPTION 74. Dumpster load - Approx. 40 yards, 7-8 tons of debris s ; 3.00 EA 75. General Demolition - per hour R�., 't ' 24.00 HR Additional labor to clean up debri from grounds, cart and dump. 76. Crane and operator - 14 ton capacity -x'65' extension boom 6.00 HR 77. Taxes, insurance, permits & fees (Bid item) 1.00 EA 78. Architectural/Drafting fees (Bid item) 1.00 EA 180. Temporary power - hookup 1.00 EA ;l 81. Panelboard_- 120/240; 100 amp, single phase (per cireuit) 1.00 EX (Temporary power was junction ed off of existing panel and approved by assigned La Quinta building inspector. Line item _lists this as an OPEN ITEM because of the location of the panel in conjunction with the fire and no immediate damage found. T1 f : will be determined by a licensed electrical contractor on necessity of replacing if determined that it was damaged or -- - 1 compromised by_the_fire and added as a supplemental item if needed:_-__ 182. Temporary fencing - 30.00 LF 183. Warning Signs and or Cones 1.00 EA Due to the proximity of the property to a main road, (the driveway runs directly into a main traffic area) we may need addional signage, cones, warnings for egress into the property. 401. Temporary toilet (per month) 6.00 MO 402. Residential supervision - per hour 40.00 HR Supervisory hrs to expidite permitting and engineering, scheduling, subcontractors, supervision and job management. NOTES: HANSEN-FIRE-SF e 10/28/2010 Page:2 , Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 b Missing Wall: DESCRIPTION Garage 622.00 SF Walls 1084.86 SF Walls & Ceiling ~" 51.43 SY Flooring ' 91.75 LF Ceil. Perimeter 1 1 - 16' X 7' Opens into Exterior Height: 8' 462.86 SF Ceiling 462.86 SF Floor 75.75 LF Floor Perimeter Goes to Floor 1. Demolish/remove - garage/room (up to 200 sf) 2. Truss.- 4/12 slope 403. Sheathing - plywood - 1/2" CDX 3. Carpenter - General Framer - per hour Additional labor for blocking, crossbracing, lookouts and barge rafter. 4. 5/8" drywall - hung, taped, floated, ready for paint 5. Batt insulation - 4" - R13 '6: Blown -in insulation - 14" depth -1138 `Minimum Requirements as per building energy analysis report is R30 for ceilings and R 13 for walks. 7. Seal then paint the walls and ceiling twice (3 coats) 8. Clean with pressure/chemical spray - Heavy 392. Paint concrete the floor 9. Rewire - average residence - copper wiring 10. Outlet 11. Switch 12. Fluorescent - two tube - 4'- strip- light Fixture to meet 2008 energy requirements. Note E1.0 of FIRE DAMAGE REPAIR PIAN_ . 13. Overhead door & hardware - 16'x T- High grade 14. Paint overhead door -Large - 2 coats (per side) 15. Water beater - 50 gal - Residential grade - Gas Water heater as per Building Energy Analysys Report, 16. Heating and cooling unit - 2 ton, 80 MBH 391. Ductwork system - hot or cold air - 1200 to 1599 SF home Will require HERS testing and acceptance standards. HANSEN-FIRE-SF 10/28/2010 QNTY 462.86 SF 315.00 LF 462.86 SF 24.00 HR 1084.86 SF 622.00 SF 462.86 SF 1084.86 SF 462.86 SF 462.86 SF 462.86 SF 4.00 EA 2.00 EA 4.00 EA 1.00 EA 1.00 EA 1.00 EA 1.00 EA 1.00 EA Page: 3 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Garage DESCRIPTION QNTY 389. Exterior door - metal - insulated - flush or panel style 1.00 EA 393. Paint door slab only - 2 coats (per side) 1.00 EA 394. Paint door or window opening - 2 coats (per side) 2.00 EA 395. Door lockset - exterior 2.00 EA 399. Deadbolt 1.00 EA 398. Steel door, Y x T- fire rated 1.00 EA 396. Door hinges - Standard grade (set of 2) 1.00 EA Self closing hinges. NOTES: saw Laundry Room 126.67 SF Walls T T 141.07 SF Walls & Ceiling m 1.60 SY Flooring 1 15.83 LF Ceil. Perimeter 5' 5' DESCRIPTION 18. Demolish/remove - kitchen/laundry 35. 1/2" drywall - hung, taped, floated, ready for paint 52. Seal then paint the walls and ceiling twice (3 coats) 93. Saltillo tile 12" x 12" 94. Mortar bed for file floors 95. Tiletstone sealer Height: 8' 14.40 SF Ceiling 14.40 SF Floor 15.83 LF Floor Perimeter QNTY 14.40 SF 141.07 SF 141.07 SF 14.40 SF 14.40 SF 14.40 SF HANSEN-FIRE-SF 10/28/2010 Page:4 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Laundry Room DESCRIPTION 167. Interior door - full louvered - pre -hung unit 173. Cabinet knob or pull 203. Clothes dryer vent - installed 172. Paint full louvered door slab only - 2 coats (per side) 168. () Washer/Washing Machine - Top -loading Supplied by others 170. 0 Dryer - Gas Supplied by others 171. Shelving - 12" -in place NOTES: Kitchen � r M 1 N F ag s --r T 1 t Missing Wall: 1 - 7' 413/16" X 8' Missing Wall: 1- 4' 7 7/16" X 8' DESCRIPTION 19. Demolishlremove - Idtchen/laundry HANSEN-FIRE-SF 291.80 SF Walls 407.47 SF Walls & Ceiling 12.61 SY Flooring 40.90 LF Ceil. Perimeter Opens into FAMILY Opens into ROOM2 QNTY 1.00 EA 2.00 EA 1.00 EA 2.00 EA 1.00 EA 1.00 EA 6.00 LF Height: Sloped 115.68 SF Ceiling 113.53 SF Floor 33.17 LF Floor Perimeter Goes to Floor/Ceiling Goes to Floor/Ceiling QNTY 113.53 SF 10/28/2010 Page:5 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 CONTOWED - Kitchen DESCRIMON QNTY 36. 1/2" drywall - hung, taped, floated, ready for paint 407.47 SF Orange peal texture only 53. Seal then paint the walls and ceiling twice (3 coats) 407.47 SF � Cabinet layout and electrical layout listed on FIRE DAMAGED RESTORATION -PLAN (E1.0) i 184. Cabinetry - lower (base) units - High grade 16.83 LF 185. Cabinetry - full height unit - High grade 3.00 LF 186. Cabinetry - upper (wall) units - High grade 13.50 LF 187. Countertop subdeck - plywood 38.00 SF 188. Ceramic tile 46.00 SF 189. Ceramic file - bullnose - 2" x 6" 27.80 LF 190. Mortar bed for ceramic tile 38.00 SF Counter Top. 191. Sink - double - High grade 1.00 EA 192. P -trap assembly - ABS (plastic) 1.00 EA 193. Angle stop 2.00 EA 194. Plumbing fixture supply line 2.00 EA 195. Dishwasher 1.00 EA 196. Refrigerator - side by side - 16 to 22 cf - High grade 1.00 EA 197. Range - freestanding - gas - High grade 1.00 EA 410. Range hood - High grade 1.00 EA ' 198. Fluorescent light fixture - High grade 4.00 EA Code requirements may include additional lighting. Specifications listed on ELO 96. Saltillo tile 12" x 12" 113.53 SF 97. Mortar bed for tile floors 113.53 SF 98. Tile/stone sealer 113.53 SF 199. Rewire - average residence - copper wiring 113.53 SF 200. Ground fault interrupter (GFI) outlet 1.00 EA 201. Outlet 4.00 EA 202. Switch 2.00 EA Once the walls are opened we will be able to assess the gas lines, plumbing supply and waste lines for damage. A pressure test will be required. HANSEN-FIRE-SF 10/28/2010 Page:6 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION NOTES: Family Room Missing Wall: 1- 6' 1111/16" X 8' Missing Wall: 1- 12' 1/8" X 8' Missing Wall: 1- 3'3 3/16" X 8' Missing Wall: 1- 7' 413/16" X 8' DESCRIMON CONTINUED - Kitchen 374.86 SF Walls 652.92 SF Walls.& Ceiling 30.49 SY Flooring 69.86 LF Ceil. Perimeter Opens into ENTRY Opens into ROOM2 Opens into ROOM2 Opens into KITCHEN 20. Demolish/remove - bedroom/room (up to 200 sf) 37. 1/2" drywall - hung, taped, floated, ready for paint 54. Seal then paint the walls and ceiling twice (3 coats) 99. Saltillo tile 12" x 12" 100. Mortar bed for file floors 101. Tiletstone sealer 308. French double doors - Exterior - pre -hung unit 309. Paint French door slab only - 2 coats (per side) 310. Paint door or window opening - Large - 2 coats (per side) HANSEN-FIRE-SF QNTY Height: Sloped 278.06 SF Ceiling 274.43 SF Floor 39.60 LF Floor Perimeter Goes to Floor/Ceiling Goes to Floor/Ceiling Goes to Floor/Ceiling Goes to Floor/Ceiling 10/28/2010 QNTY 274.43 SF 652.92 SF 652.92 SF 274.43 SF 274.43 SF 274.43 SF 1.00 EA 2.00 EA 1.00 EA Page: 7 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Family Room DESCRIPTION QNTY X311. Light Sxbuv i 1.00 EA F Line Item listed as Open, It was hard to determine if there are any ceiling lights. Most likely this had switched lamps. All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0� 312. Baseboard - 2 1/4" 39.60 LF 313. Paint baseboard - two coats 39.60 LF 422. Rewire - average residence - copper wiring 274.43 SF 423. Switch 2.00 EA 424. Outlet 6.00 EA NOTES: ,? Dining Room b � H 289.68 SF Walls 405.80 SF Walls & Ceiling 12.78 SY Flooring 40.70 LF Ceil. Perimeter Height: Sloped 116.12 SF Ceiling 115.06 SF Floor 25.18 LF Floor Perimeter Missing Wall: 1- 12' 1/8" X 10' Opens into FAMILY Goes to Floor/Ceiling Missing Wall: 1- Y3 3/16" X 10' Opens into FANULY Goes to Floor/Ceiling Missing Wall: 1 - 4'7 7/16" X 10' Opens into KITCHEN Goes to Floor/Ceiling DESCRIPTION 21. Demolish/remove - bedroom/room (up to 200 sf) QNTY 115.06 SF HANSEN-FIRE-SF 10/28/2010 Page:8 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Dining Room DESCRIPTION QNTY 38. 1/2" drywall - hung, taped, floated, ready for paint 405.80 SF 55. Seal then paint the walls and ceiling twice (3 coats) 405.80 SF 102. Saltillo tile 12" x 12" 115.06 SF 103. Mortar bed for tile floors 115.06 SF 104. Tiletstone sealer 115.06 SF 314. Baseboard - 2 1/4" 25.18 LF 315. Paint baseboard - two coats 25.18 LF 316. Rewire - average residence - copper wiring 115.06 SF 317. Switch 2.00 EA 318. Outlet 4.00 EA 319. Hanging fight fixture - Higbgrade­ 1.00 EA ' All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0)� NOTES: HANSEN-FIRE-SF 10/28/2010 Page:9 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 Entry/Foyer 116.38 SF Walls 171.84 SF Walls & Ceiling 6.07 SY Flooring 32.67 LF Ceil. Perimeter Height: Sloped 55.46 SF Ceiling 54.60 SF Floor 7.26 LF Floor Perimeter Missing Wall: 1 - 9' 7 1/8" X 11' Opens into LIVING Goes to Floor/Ceiling Missing Wall: 1- 2'7 1/8" X 11' Opens into LIVING Goes to Floor/Ceiling Missing Wall: 1- 2' 17/8" X 11' Opens into LIVING Goes to Floor/Ceiling Missing Wall: 1- 3'6" X 11' Opens into HALL Goes to Floor/Ceiling Missing Wall: 1- 6' 1111/16" X 11' Opens into FAMILY Goes to Floor/Ceiling F2'3"1 Subroom 1: OFFSET Missing Wall: 1-. 3'9 3/8" X 8' DESCRIPTION 62.90 SF Walls 70.62 SF Walls & Ceiling 0.86 SY Flooring 11.64 LF Ceil. Perimeter Opens into ENTRY 22. Demolish/remove - bedroom/room (up to 200 sf) 39. 1/2" drywall - hung, taped, floated, ready for paint 56. Seal then paint the walls and ceiling twice (3 coats) 105. Saltillo tile 12" x 12" 106. Mortar bed for tile floors 107. Tile/stone sealer 320. Baseboard - 2 1/4" 321. Paint baseboard - two coats 322. Door chime Height: 8' 7.72 SF Ceiling 7.72 SF Floor 7.86 LF Floor Perimeter Goes to Floor/Ceiling QNTY 62.32 SF 242.46 SF 242.46 SF 62.32 SF 62.32 SF 62.32 SF 15.12 LF 15.12 LF 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 10 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Entry/Foyer DESCRIPTION QNTY C- 323.- Banging light fixture 1.00 EA rAll replaced light fixtures to meet 2008 energy Requirements (typ.)'uote FIRE DAMAGE RESTORATION PLAN (ELOY 324. Exterior door - metal - insulated - flush or panel style 1.00 EA 325. Door lockset - exterior 1.00 EA 326. Deadbolt 1.00 EA 327. Door stop = Wall or floor mounted 1.00 EA 328. Prime & paint door slab only - exterior (per side) 1.00 EA 329. Paint door or window opening - 2 coats (per side) 1.00 EA 330. Rewire - average residence - copper wiring 62.32 SF 331. Switch 3.00 EA NOTES: Living Room 428.35 SF Walls 673.18 SF Walls & Ceiling b 26.51 SY Flooring 62.44 LF Ceil. Perimeter Height: Sloped 244.83 SF Ceiling 238.56 SF Floor 47.44 LF Floor Perimeter Missing Wall: 1- 2' 17/8" X 8' Opens into ENTRY Goes to Floor/Ceiling Missing Wall: 1- 2' 7 1/8" X 8' Opens into ENTRY Goes to Floor/Ceiling Missing Wall: 1- 9'7 1/8" X 8' Opens into ENTRY Goes to Floor/Ceiling HANSEN-FIRE-SF 10/28/2010 Page: ll Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION QNTY 23. Demolish/remove - bedroom/room (up to 200 sf) 238.56 SF 40. 1/2" drywall - hung, taped, floated, ready for paint 673.18 SF 57. Seal then paint the walls and ceiling twice (3 coats) 673.18 SF 108. Carpet - per specs from independent carpet analysis 274.35 SF 15 % waste added for Carpet - per specs from independent carpet analysis. 109. Carpet pad - per specs from independent pad analysis 238.56 SF .332. -Aluminum window, horiz. slider 12-23 sf (2 pane) 1.00 EA 333. Aldminum window, horiz. slider 2432 sf (2 pane) a 1.00 EA 334. Aluminum window - casement, 6-8 sf - High grade P 2.00 EA Listed on FIRE DAMAGE REPAIR PLAN- S3.1 window schedule 335. Add on for grid (double or triple glazed windows) 60.00 SF 336. Add on for "Low E" glass 60.00 SF 337. Paint door or window opening - Large - 2 coats (per side) 2.00 EA 338. Paint door or window opening - 2 coats (per side) 2.00 EA 339. Window blind - PVC - 3.5" - 7.1 to 14 SF - High grade 2.00 EA 340. Window blind - PVC - 3.5" - up to 7 SF - High grade 2.00 EA NOTES FPL T 113.88 SF Walls `� 122.58 SF Walls & Ceiling 5�� 0.97 SY Flooring �` s' z• -� 14.24 LF Ceil. Perimeter 1 HaG-W DESCRIPTION Height: 8' 8.69 SF Ceiling 8.69 SF Floor 14.24 LF Floor Perimeter 41. 1/2" drywall - hung, taped, floated, ready for paint Drywall hearth and mantle,with detail, round corners. 247. Fireplace, zero Once, wood burning, w/ venting Replace with like kind and quality- To meet energy standards. Listed on FIRE DAMAGE REPAIR PLAN -S3.1 HANSEN-FIRE-SF 10/28/2010 QNTY 122.58 SF 1.00 EA Page: 12 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - FPL DESCRIPTION QNTY 58. Seal then paint the walls and ceiling twice (3 coats) 122.58 SF NOTES: � r 2MA ,. 0-1 Bedroom -1 n T e 384.00 SF Walls T 499.33 SF Walls & Ceiling 12.61 SY Flooring - f 3P ,, 43.02 LF Ceil. Perimeter F 3'3.4 F313o4 2'4' DESCRIPTION Subroom 1: CLST 195.00 SF Walls 2 13. 11 SF Walls & Ceiling 1.96 SY Flooring 22.11 LF Ceil. Perimeter 25. Demolish/remove - bedroom/room (up to 200 sf) 42. 1/2" drywall - hung, taped, floated, ready for paint 59. Seal then paint the walls and ceiling twice (3 coats) 110. Carpet - per specs from independent carpet analysis 15 g$ waste added for Carpet - per specs from independent carpet analysis. 111, Carpet pad - per specs from independent pad analysis HANSEN-FIRE-SF Height: Sloped 115.33 SF Ceiling 113.53 SF Floor 42.67 LF Floor Perimeter Height: Sloped 18.11 SF Ceiling 17.67 SF Floor 21.67 LF Floor Perimeter MIU-W 131.19 SF 712.45 SF 712.45 SF 150.87 SF 131.19 SF 10/28/2010 Page: 13 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Bedroom -1 DESCRIPTION QNTY 112. Baseboard - 2 1/4" 64.33 LF 113. Paint baseboard - two coats 64.33 LF 114. Bypass (sliding) door set - Colonist 1.00 EA 251. Paint bypass door set - slab only - 2 coats (per side) 4.00 EA 252. Cabinet knob or pull 2.00 EA 253. Interior door unit 1.00 EA 118. Door knob - interior 1.00 EA 225. Door stop - Wall or floor mounted 1.00 EA 115. Paint door slab only - 2 coats (per side) 1.00 EA 116. Paint door/window trim & jamb - 2 coats (per side) 4.00 EA 226. Window blind - PVC - 2" - 7.1 to 14 SF - High grade 1.00 EA 249. Closet shelf and rod package 9.00 LF 250. Seal & paint closet shelving - single shelf 9.00 EA 254. Clean window unit (per side) 10 - 20 SF - Heavy 1.00 EA 139. Rewire - averake residence - copper wiring131.19 SF /Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wallis opened_up and inspection by a certified electrical contractor is verifications of damages and repairsFwill be addressed, any code r upgrades if needed will be add_ re_ ssed as a supplement to this estimate. 140. Ceiling fan & light 1.00 EA All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN 04) ? 144. Outlet 4.00 EA 145. Switch 307. Smoke detector NOTES: 1.00 EA 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 14 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 i Coat Height: 8' 3? 64.00 SF Walls 4.00 SF Ceiling 1 68.00 SF Walls & Ceiling 4.00 SF Floor ry N 0.44 SY Flooring 8.00 LF Floor Perimeter F11 1 8,00 LF Ceil. Perimeter DESCRIPTION QNTY 26. Demolishlremove - bedroom/room (up to 200 sf) 4.00 SF 43. 1/2" drywall - hung; taped, floated, ready for paint 68.00 SF 60. Seal then paint the walls and ceiling twice (3 coats) 68.00 SF 228. Closet shelf and rod package 2.00 LF 229. Interior door unit 1.00 EA 245. Paint door slab only - 2 coats (per side) 1.00 EA 246. Paint door or window opening - 2 coats (per side) 1.00 EA 230. Door knob - interior 1.00 EA 231. Door stop - Wall or floor mounted 1.00 EA 232. Saltillo tile 12" x 12" 4.00 SF 233. Mortar bed for tile floors 4.00 SF 234. Tiletstone sealer 4.00 SF 243. Baseboard - 2 1/4" 8.00 LF 244. Paint baseboard - two coats 8.00 LF NOTES: HANSEN-FIRE-SF 10/28/2010 Page: 15 r3'2' r Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 411• 4-i-39' X91•-� I-3'T� Bedroom -2 420.94 SF Walls 549.17 SF Walls & Ceiling 14.02 SY Flooring 47.36 LF Ceil. Perimeter Subroom 1: CLST 180.00 SF Walls 198.50 SF Walls & Ceiling 2.06 SY Flooring 22.50 LF Ceil. Perimeter Height: Sloped 128.23 SF Ceiling 126.22 SF Floor 47.00 LF Floor Perimeter Height: 8' 18.50 SF Ceiling 18.50 SF Floor 22.50 LF Floor Perimeter DESCRIPTION QNTY 27. Demolish/remove - bedroom/room (up to 200 sf) 144.72 SF 44. 1/2" drywall - hung, taped, floated, ready for paint 747.67 SF 61. Seal then paint the walls and ceiling twice (3 coats) 747.67 SF 130. Carpet - per specs from independent carpet analysis 166.43 SF 15 % waste added for Carpet - per specs from independent carpet analysis. 131. Carpet pad - per specs from independent pad analysis 144.72 SF 132. Baseboard - 2 1/4" 69.50 LF 133. Paint baseboard - two coats 69.50 LF 255. Bypass (sliding) door set - Colonist 1.00 EA 257. Cabinet knob or pull 1.00 EA 256. Paint bypass door set - slab only - 2 coats (per side) 4.00 EA 134. Interior door unit 1.00 EA 135. Door knob - interior 1.00 EA 224. Door stop - Wall or floor mounted 1.00 EA 136. Paint door or window opening - 2 coats (per side) 4.00 EA 137. Paint door slab only - 2 coats (per side) 1.00 EA 138. Ceiling fan &light) 1.00 EA All replaced light fixtures to meet 2008 energy Requirements (typ.) note -FIRE DAMAGE RESTORATION PLAN (E1.0) 141. Rewire - average residence - copper wiring _ - - - - - - -- - - -- - -- -- - - ---- ---144:72"SF 142. Outlet 4.00 EA 143. Switch 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 16 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION 306. Smoke detector NOTES: 4'7' - ,� 4 -5 - "St ast G G. DESCRIPTION CONTINUED - Bedroom -2 Mst Clst T 195.27 SF Walls 230.91 SF Walls & Ceiling 1 3.96 SY Flooring 24.41 LF Ceil. Perimeter 28. Demolish/remove - bedroom/room (up to 200 sf) 45. 1/2" drywall - hung, taped, floated, ready for paint 62. Seal then paint the walls and ceiling twice (3 coats) 128. Carpet - per specs from independent carpet analysis. 15 % waste added for Carpet - per specs from independent carpet analysis. 129. Carpet pad - per specs from independent pad analysis 235. Interior door unit 239. Door knob - interior 240. Door stop - Wall or floor mounted 236. Paint door slab only - 2 coats (per side) 237. Paint door or window opening - 2 coats (per side) 238. Closet shelf and rod package 258. Seal & paint closet shelving - single shelf 1.00 EA Height: 8' 35.63 SF Ceiling 35.63 SF Floor 24.41 LF Floor Perimeter QNTY 35.63 SF 230.91 SF 230.91 SF 40.98 SF 35.63 SF 1.00 EA 1.00 EA 1.00 EA 1.00 EA 1.00 EA 16.00 LF 16.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 17 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Mst CIA DESCRIPTION QNTY 241. Baseboard - 2 1/4" 24.41 LF 242. Paint baseboard - two coats 24.41 LF 447. Light fixture 1.00 EA AD replaced light fixtures to meet 2,008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0) NOTES: u Hallway r •s r—r r iiar e err---ra ira.•I — r a Missing Wan: DESCRIPTION 285.71 SF Walls 341.39 SF Walls & Ceiling 6.19 SY Flooring 35.71 LF Ceil. Perimeter 1- 3'6" X 8' Opens into ENTRY 29. Demolish/remove - bedroom/room (up to 200 sf) 46. 1/2" drywall - hung, taped, floated, ready for paint 63. Seal then paint the walls and ceiling twice (3 coats) 119. Saltillo file 12" x 12" 120. Mortar bed for file floors 121. Tile/stone sealer (146. Rewire --average residence__-_copper.wiring HANSEN-FIRE-SF Height: 8' 55.68 SF Ceiling 55.68 SF Floor 35.71 LF Floor Perimeter Goes to Floor/Ceiling 10/28/2010 QNTY 55.68 SF 341.39 SF 341.39 SF 55.68 SF 55.68 SF 55.68 SF 55.68 SF Page: 18 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Hallway DESCRIPTION QNTY 'All fire damaged wireing in attic will be replaced, the wall outlets willbe determined after demolition. 147. Outlet 3.00 EA 148. Switch - 3 way 3.00 EA 149. Baseboard - 2 1/4" 35.71 LF 150. Paint baseboard - two coats 35.71 LF 151. Paint door slab only - 2 coats (per side) 3.00 EA 409. Paint full louvered door slab only - 2 coats (per side) 2.00 EA 152. Paint door or window opening - 2 coats (per side) 4.00 EA 153: Light fixture 2.00 EA 'All replaced light fixtures to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1.0)7 155. Thermostat 1.00 EA NOTES: Bathroom 295.98 SF Walls 357.06 SF Walls & Ceiling 6.79 SY Flooring 37.00 LF Ceil. Perimeter Height: 8' 61.08 SF Ceiling 61.08 SF Floor 37.00 LF Floor Perimeter HANSEN-FIRE-SF 10/28/2010 Page: 19 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION Subroom 1: LINEN 74.65 SF Walls 79.40 SF Walls & Ceiling 0.53 SY Flooring 9.33 LF Ceil. Perimeter Height: 8' 4.75 SF Ceiling 4.75 SF Floor 9.33 LF Floor Perimeter 30. Demolish/remove - bathroom (up to 50 sf) 65.83 SF 47. 1/2" drywall - hung, taped, floated, ready for paint 436.46 SF 64. Seal then paint the walls and ceiling twice (3 coats) 436.46 SF 122. Saltillo file 12" x 12" 65.83 SF 123. Mortar bed for tile floors 65.83 SF 124. Tile/stone sealer 65.83 SF 156. Interior door unit 1.00 EA 157. Paint door slab only - 2 coats (per side) 1.00 EA 158. Paint door or window opening - 2 coats (per side) 1.00 EA 159. Baseboard - 2 1/4" 46.33 LF 160. Paint baseboard - one coat 46.33 LF 205. Bathroom ventilation fan - High grade 1.00 EA 259. Vanity 5.00 LF 260. Countertop subdeck - plywood 10.00 SF 261. Mortar bed for ceramic tile 10.00 SF 262. Countertop - Tile 12.50 SF 412. Ceramic tile - bullnose - 2" x 6" 5.00 LF 263. Mirror - 1/4" plate glass 15.00 SF 264. Medicine cabinet 1.00 EA 165. Light bar - 4 lights - High grade 1.00 EA This fixture is cleanable and may not need to be replaced and will be determined duirring electrical inspections._ If replaced will. meet 2008 energy requirements. - - - - 450. Rewire - average residence - copper wiring with conduit 65.83 SF Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened up =and inspection by a certified electrical contractor -is verifications of damages and repairs will be addressed, any code-,,, -� upgrades if needed will be addressed as a supplement to this estimate. This scope of work is to clean tub/surround, sink, toilet and fixtures. Once we can determine if not salvageable we can adjust for replacement and add as a supplement to this estimate. 266. Toilet - Detach & reset 1.00 EA HANSEN-FiRE-SF 10/28/2010 Page: 20 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION 267. Clean toilet - Heavy 268. Q Bathtub - Detach & reset If Cleanable we will not need to remove. 273. 0 Sink - single 269. Clean tub and surround - Heavy 271. Clean shower door - Heavy 272. Clean sink and faucet - Heavy 299. Bath accessory 416. P -trap assembly - ABS (plastic) 417. Angle stop 418. Plumbing fixture supply line NOTES: Missing Wall: Master Bedroom 1 - 4' 11" X 8' CONTINUED - Bathroom 505.05 SF Walls 683.41 SF Walls & Ceiling 19.31 SY Flooring 51.32 LF Ceil. Perimeter Opens into VANITY QNTY 1.00 EA 1.00 EA 1.00 EA 1.00 EA 1.00 EA 1.00 EA 3.00 EA 1.00 EA 3.00 EA 3.00 EA Height: Sloped 178.36 SF Ceiling 173.79 SF Floor 50.44 LF Floor Perimeter Goes to Floor/Ceiling DESCRIPTION QNTY HANSEN-FIRE-SF 10/28/2010 Page: 21 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lie # 677877 CONTINUED - Master Bedroom DESCRIPTION QNTY 32. Demolish/remove - bedroom/room (up to 200 sf) 173.79 SF 49. 1/2" drywall - hung, taped, floated, ready for paint 683.41 SF 66. Seal then paint the walls and ceiling twice (3 coats) 683.41 SF 210. Window blind - wood - 1 " - 14.1 to 20 SF 2.00 EA Blinds covering Patio door and window light. 211. Carpet - per specs from independent carpet analysis 199.86 SF 15 % waste added for Carpet - per specs from independent carpet analysis. 212. Carpet pad - per specs from independent pad analysis 173.79 SF 213. Baseboard - 2 1/4" 50.44 LF 214. Paint baseboard - two coats 50.44 LF 215. Interior door unit 1.00 EA 216. Door knob - interior 1.00 EA 223. Door stop - Wall or floor mounted 1.00 EA 217. Paint door or window opening - 2 coats (per side) 2.00 EA 218. Paint door slab only - 2 coats (per side) 1.00 EA 303. Clean door - French (per side) 4.00 EA 219. Ceiling fan without light ? 1.00 EA All replaced light fixtures'to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION PLAN -(El. 0� 220. Rewire - average residence - copper wiring 173.79 SF ,Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened up> and inspection by a certified electrical contractor is verifications of damages and repairs will be addressed, any code- upgrades odeupgrades if needed will be addressed as a supplement to this estimate. A f 221. Outlet 4.00 EA 222. Switch 1.00 EA 305. Smoke detector 1.00 EA NOTES: HANSEN-FIRE-SF 10/28/2010 Page: 22 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 3' -�2' 6' 6" .T 2 Q Mast lD 5 8- � 1 DESCRIPTION 1 Master Bath 185.33 SF Walls 218.86 SF Walls & Ceiling Cl�atss.� 3.73 SY Flooring 23.17 LF Ceil. Perimeter Height: 8' 33.53 SF Ceiling 33.53 SF Floor 23.17 LF Floor Perimeter QNTY 31. Demolishlremove - bedroom/room (up to 200 sf) 33.53 SF 48. 1/2" drywall - hung, taped, floated, ready for paint 218.86 SF 65. Seal then paint the walls and ceiling twice (3 coats) 218.86 SF 125. Saltillo tile 12" x 12" 33.53 SF 126. Mortar bed for tile floors 33.53 SF 127. Tile/stone sealer 33.53 SF 206. Bathroom ventilation fan - High grade 1.00 EA 'This scope of work is to clean tub/surround, sink, toilet and fixtures. Once we can determine if not salvageable we can adjust 'for replacement and add as a supplement to this estimate. 274. () Bathtub - Detach & reset 1.00 EA If cleanable we will not need to remove. 275. Clean tub and surround - Heavy 1.00 EA 276. Clean shower - Heavy 1.00 EA 277. Clean shower door - Heavy 1.00 EA 281. Clean toilet - Heavy 1.00 EA 280. () Toilet 1.00 EA 282. Interior door unit 1.00 EA 284. Door knob - interior 1.00 EA 285. Door stop - Wall or floor mounted 1.00 EA 283. Paint door slab only - 2 coats (per side) 1.00 EA 286. Paint door or window opening - 2 coats (per side) 1.00 EA 287. Bath accessory 2.00 EA 301. Rewire - average residence --copper wiring _ 33.53 SF _ Fire did not penetrate wall cavity and no damage has been determined to the existing electrical, once the wall is opened np land_inspection by a certified electrical contractor is verifications of damages and repairs will be addressed any code lupgradas if needed will be addressed as a supplement to this estimate: i' 302. Ground fault interrupter (GFI) outlet 1.00 EA 420. Angle stop 1.00 EA 421. Plumbing fixture supply line 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 23 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Master Bath DESCRIPTION 449. Light fixture - Detach & reset 448. Clean light fixture NOTES: i—s. Missing Wall: DESCRIPTION Vanity Area/Room 1- 4' 11" X 8' 134.00 SF Walls 162.68 SF Walls & Ceiling 3.19 SY Flooring 16.75 LF Ceil. Perimeter Opens into MSTRBDRM 33. Demolish/remove - bedroom/room (up to 200 sf) 50. 1/2" drywall - hung, taped, floated, ready for paint 67. Seal then paint the walls and ceiling twice (3 coats) 161. Saltillo tile 12" x 12" 162. Mortar bed for tile floors 163. Tile/stone sealer 289. Q Sink - single 290. Q Sink faucet - Bathroom 288. Clean sink and faucet HANSEN-FIRE-SF QNTY 1.00 EA 1.00 EA Height: 8' 28.68 SF Ceiling 28.68 SF Floor 16.75 LF Floor Perimeter Goes to Floor/Ceiling 10/28/2010 `tom 28.68 SF 162.68 SF 162.68 SF 28.68 SF 28.68 SF 28.68 SF 1.00 EA 1.00 EA 1.00 EA Page: 24 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Vanity Area/Room DESCRIPTION QNTY 298. Bath accessory 1.00 EA 291. Vanity 5.00 LF 292. Countertop subdeck - plywood 10.00 SF 293. Mortar bed for ceramic tile 10.00 SF 294. Countertop - Tile 12.50 SF 411. Ceramic tile - bullnose - 2" x 6" 5.00 LF 295. Mirror - 1/4" plate glass 15.00 SF 296. Medicine cabinet 1.00 EA 297. Light bar - 4 lights - High grade 1.00 EA -This fixture is cleanable and may not need to be replaced and `will be determined durring electrical inspections. N replaces will meet 2008 energy requirements and comply with current codes, _ 300. Rewire -average residence - copper wiring 28.68 SF Fire did not penetrate wall cavity and no damage has been determined to the eristing electrical, once the wall is opened p� and inspection by a certified electrical contractor is verifications of damages and repairs will be addressed, any code ]� upgrades if needed will be addressed as a supplement to this estimate. - 413. P -trap assembly ABS (plastic) 1.00 EA 414. Angle stop 2.00 EA 415. Plumbing fixture supply line NOTES 6' comer e,u _j Linin 5.8. Q 122.65 SF Walls 133.98 SF Walls & Ceiling 1.26 SY Flooring 15.33 LF Ceil. Perimeter 2.00 EA Height: 8' 11.33 SF Ceiling 11.33 SF Floor 15.33 LF Floor Perimeter HANSEN-FIRE-SF 10/28/2010 Page: 25 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 - office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION 344. 1/2" drywall - hung, taped, floated, ready for paint 345. Seal then paint the walls and ceiling twice (3 coats) 346. Bifold door set - full louvered - Double 347. Paint full louvered door slab only - 2 coats (per side) 348. Baseboard - 2 1/4" 349. Paint baseboard - two coats 350. Saltillo tile 12" x 12" 351. Mortar bed for tile floors 352. Tile/stone sealer 353. Shelving - 24" - in place 354. Seal & paint closet shelving - single shelf NOTES: Patio 270.00 SF Walls 515.46 SF Walls & Ceiling 27.27 SY Flooring 33.75 LF Ceil. Perimeter QNTY 133.98 SF 133.98 SF 1.00 EA 4.00 EA 15.33 LF 15.33 LF 11.33 SF 11.33 SF 11.33 SF 20.00 LF 4.00 EA Height: 8' 245.46 SF Ceiling 245.46 SF Floor 33.75 LF Floor Perimeter Missing Wall: 1- 22' 10" X 8' Opens into Exterior Goes to Floor/Ceiling Missing Wall: 1- 10' 9" X 8' Opens into Exterior Goes to Floor/Ceiling DESCRIPTION QNTY 355. Clean soffit -wood 245.46 SF 356. Prime & paint exterior soffit - exposed rafters 245.46 SF 357. Clean with pressuretchemical spray 245.46 SF 358. Paint/finish - fence post - wood. 3.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 26 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - Patio DESCRIPTION NOTES: Walkway Missing Wall: 1- 23' 6 1/2" X 8' Missing Wall: 1 - 5' 101/2" X 8' 267.33 SF Walls 417.06 SF Walls & Ceiling 16.64 SY Flooring 33.42 LF Ceil. Perimeter Opens into Exterior Opens into Exterior QNTY Height: 8' 149.72 SF Ceiling 149.72 SF Floor 33.42 LF Floor Perimeter Goes to Floor/Ceiling Goes to Floor/Ceiling DESCRIPTION QNTY 342. Clean with pressure/chemical spray 299.45 SF Clean soft and Walk way for sealing and or paint. 343. Seal & paint stucco 149.72 SF NOTES: Footprint HANSEN-FIRE-SF 10/28/2010 Page: 27 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION 70. Batt insulation - 4" - R13 Living Area 1690.00 SF Walls 3290.66 SF Walls & Ceiling 174.37 SY Flooring 184.22 LF Ceil. Perimeter Height: Peaked 1600.66 SF Ceiling 1569.37 SF Floor 182.64 LF Floor Perimeter 69. Blown4n insulation -14" depth --R38 �'—Miinimum Requirements as per buil ' ene inal sis report is R30 for ceilin q ' p durg rgy _ y po gs and R 13 for waDs. 174. Seal stud wall for odor control Exterior Walls 176. Seal stud wall for odor control Interior Walls 175. Seal attic framing (white pigmented shellac) - up to 5/12 400. Deodorize building - Ozone treatment 425. Final cleaning - construction - Residential NOTES: Exterior Exterior DESCRIPTION QNTY 1690.00 SF 1600.66 SF 1690.00 SF 1720.00 SF 1600.66 SF 18832.46 CF 1569.37 SF QNTY 359. Wood fence 5'- 6'- high - cedar 16.00 LF Due -to repair fire damaged fencing slats only, (maximum of 30'), and discussion with City of Laquinta building reveiwer no Cseparate permit is required, just need to include on plan. refer to FIRE DAMAGED REPAIR -PLAN.,S3.1-- 360. Seal & paint - wood fence/gate 360.00 SF HANSEN-FIRE-SF 10/28/2010 Page: 28 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION NOTES L� DESCRIPTION CONTINUED - Exterior East Elevation 220.00 SF Walls 220.00 SF Long Wall 21.54 LF Ceil. Perimeter Subroom 1: Entry 209.00 SF Walls 209.00 SF Long Wall 20.62 LF Ceil. Perimeter QNTY Formula Elevation 20'x 9'x 4' 20.00 LF Floor Perimeter 220.00 SF Short Wall Formula Elevation 19'x 9'x 4' 19.00 LF Floor Perimeter 209.00 SF Short Wall QNTY 80. Metal lath & stucco _ — _ - --. - --- — _ - _ _ _ _ _ _ - - ---.267.00 SF Stuccoreplacement include gable ends minus doors and windows, All wall surface of this elevation is listed to be replaced due l to the removal of stucco to replace heat damaged insulation backer -REPLACE AS WAS WITH 1" foam backer, screen, and 1 L5/8" of stucco to meet NIINIIMIUM OF 7/8" stucco as listed on FIRE DAMAGE REPAIR PLAN- S3.2 - - - —J x-83. Prime &paint door slab only - exterior (per side) — - 2.00 EA 369. Paint door or window opening - 2 coats (per side) 1.00 EA 85. Rigid foam insulation board - 1 " 267.00 SF 86. Seal & paint stucco 429.00 SF 88. Stucco repair around doors, windows, etc - 1st floor 50.00 LF HANSEN-FIRE-SF 10/28/2010 Page: 29 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTIlVUED - East Elevation DESCRIPTION QNTY 89. Exterior light fixture 3.00 EA (All replaced light fixtui-es to meet 2008 energy Requirements (typ.) note FIRE DAMAGE RESTORATION P--LAN-(E1:0)) 91. Attic vent - gable end - vinyl - Large 2.00 EA 430. Prime & paint exterior soffit - exposed rafters 186.00 SF 431. Prime & paint exterior fascia - wood, 4"- 6" wide 93.00 LF NOTES: (�l DESCRIPTION South Elevation 396.00 SF Walls 396.00 SF Long Wall 44.00 LF Ceil. Perimeter Subroom 1: Back Patio 207.00 SF Walls 207.00 SF Long Wall 23.00 LF Ceil. Perimeter 362. Paint French door slab only - 2 coats (per side) 368. Paint door or window opening -.2 coats (per side) Formula Elevation 44'x 9' x 0" 44.00 LF Floor Perimeter 396.00 SF Short Wall Formula Elevation 23'x 9'x 0" 23.00 LF Floor Perimeter 207.00 SF Short Wall QNTY 2.00 EA 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 30 Paul Davis Restoration & Remodeling 1 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTMUED - South Elevation DESCRIPTION 429. Clean stucco QNTY 301.50 SF 452. Metal lath & stucco 301.50 SF Stucco replacement includes south wall of garage and kitchen exterior. elevation -REPLACE AS WAS WITH 1"foam backer, screen, and 5/8" of stucco to meet MINEM UM OF 7/8" stucco as listed on FIRE DAMAGE REPAIR PLAN- S3.2 = 1 364. Seal & paint stucco - ' - - 603.00 SF 366. Exterior light fixture _ 3.00 EA All replaced light fixtures to meet 2008energyRequirements (typ.) note FIRE DAMAGE RESTORATION PLAN (E1:0)j 432. Prime & paint exterior fascia - wood, 4"- 6" wide 72.00 LF 433. Prime & paint exterior soffit - exposed rafters NOTES: West Elevation 446.42 SF Walls 446.42 SF Long Wall 41.36 LF Ceil. Perimeter DESCRIPTION 374. Paint French door slab only - 2 coats (per side) 375. Paint door or window opening - Large - 2 coats (per side) 427. Clean stucco 377. -Seal & paint stucco - 378. Stucco repair around doors, -windows, ONLY - lit door 426. Attic vent - gable end - vinyl - Large 144.00 SF Formula Elevation 40' 7" x 9'x 4' 40.58 LF Floor Perimeter 446.42 SF Short Wall QNTY 2.00 EA 1.00 EA 446.42 SF 446.42 SF 20.00 LF 1.00 EA HANSEN-FIRE-SF 10/28/2010 Page: 31 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 ® 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - West Elevation DESCRIPTION 434. Prime & paint exterior soffit - exposed rafters 435. Prime & paint exterior fascia - wood, 4"- 6" wide NOTES: North Elevation 414.00 SF Walls 414.00 SF Long Wall 46.00 LF Ceil. Perimeter Subroom 1: Garage 180.00 SF Walls 180.00 SF Long Wall 20.00 LF Ceil. Perimeter DESCRIPTION 381. Prime & paint door slab only exterior (per side) 382. Paint door or window opening - 2 coats (per side) 428. Clean stucco 384::Sea18c_paint, stucco _ 385: Stucco repair around.doors, windows,ONLY -1st Hoor� -- - — --- U HANSEN-FIRE-SF 88.00 SF 44.00 LF Formula Elevation 46' x 9' x 0" 46.00 LF Floor Perimeter 414.00 SF Short Wall Formula Elevation 20'x 9' x 0" 20.00 LF Floor Perimeter 180.00 SF Short Wall 2.00 EA 1.00 EA 594.00 SF 594.00 SF 20.00 LF 10/28/2010 Page: 32 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 CONTINUED - North Elevation DESCRIPTION 388. Prime & paint exterior fascia - wood, 4"- 6" wide 436. Prime & paint exterior soffit - exposed rafters NOTES: Roof Roof DESCRIPTION QNTY 72.00 LF 144.00 SF N= 72. Q Tile roofing - Concrete - "S" or flat file 2.00 SQ `REMOVE AND REPLACE BROKEN TILES ONLY 71. Tile roofing - Concrete - "S" or flat tile 16.13 SQ REMOVE AND RESET, It is our attempt tpre place only the broken tiles and re -move and reset existing salvageable tiles and weave in new tiles to match, install appropriate felt paper.— If we cannot match the existing tiles, then we will need to replace all tiles: 407. Roofing felt - 30 lb. 30.00 SQ 'Replace felt as needed. 405. Q Ridge cap - the roofing 70.00 LF 408. Hip & ridge nailer board for tile roofing - wood 70.00 LF 406. Clean with pressure/chemical spray 2600.00 SF Power wash roofing material prior to re -installing. 404. Truss - 4/12 slope 260.00 LF Trusses over Garage. 443. Carpenter - General Framer - per hour 20.00 HR Additional labor to cut out and remove trusses and sheeting, remove gable end and hip trines, set up, clean top plate and prep for new trusses. 177. Framing hurricane to 30.00 EA 179. Sheathing - plywood - 1/2" CDX 900.00 SF Roof over Residence. 73. Truss - 4/12 slope 200.00 LF HANSEN-FIRE-SF 10/28/2010 Page: 33 Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 1314D 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 DESCRIPTION 440. Sheathing - plywood - 1/2" CDX 441. Carpenter - General Framer - per hour 442. Framing hurricane tie 444. Tile roofing - Concrete - "S" or flat tile 446. Adjustments NOTES: Grand Total Areas: 10,595.37 SF Walls 4,400.26 SF Floor 2,072.42 SF Long Wall 4,400.26 Floor Area 3,799.42 Exterior Wall Area 2,935.97 Surface Area 69.83 Total Ridge Length CONTINUED- Roof 4,454.33 SF Ceiling 488.92 SY Flooring 2,072.42 SF Short Wall 4,629.17 Total Area 447.67 Exterior Perimeter of Walls 29.36 Number of Squares 17.34 Total Hip Length QNTY 616.00 SF 20.00 HR 18.00 EA 20.00 SQ 1.00 EA 15,049.70 SF Walls and Ceiling 1,174.53 LFF1oorPerimeter 1,295.95 LF Ceil. Perimeter 8,522.95 Interior Wall Area 300.98 Total Perimeter Length HANSEN-FIRE-SF 10/28/2010 Page: 34 Main Level 16'2' 1 in Me(n Level HANSEN-FIRE-SF 10/28/2010 Page: 35 Footprint Footprint HANSEN-FIRE-SF 10/28/2010 Page: 36 I �- In 3' t' IIT G & a3x S 622'6•& b m OC (D Roof Paul Davis Restoration & Remodeling 77-833 Palapas Road Palm Desert, CA 92211 760.360.1855 — office Tax ID: 33-0576487 Lic # 677877 Sketch Roof Annotations Face Square Feet Number of Squares Slope - Rise / 12 Fl 1,114.99 11.15 4.00 F2 374.04 3.74 4.00 F4 1,008.68 10.09 4.00 F5 269.96 2.70 4.33 F6 78.84 0.79 4.00 F7 89.46 0.89 4.00 ted Total: 2,935.97 29.36 m HANSEN-FIRE-SF 10/28/2010 Page: 38 I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Fire Damage Repair -Hanson Residence 51-645 Eisenhower La Quinta, CA 92253 Project Designer: Paul Davis Restoration 77-833 Paladas Rd. Palm Desert, CA 92211 (760) 360-1185 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATEiwBY & Lao.=. IRM -06 ------ Job Number: Date: 10/15/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 5.1 by EnergySoft User Number.- L. r: • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Fire Damage Repair -Hanson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11011512010 Date Project Address 51-645 Eisenhower La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,569 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 1,569 Altered Wall Wood Framed R-13 1,433 Altered Door Opaque Door None 20 Altered Slab Unheated Slab -on -Grade None 1,569 Perim = 196' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 32.0 0.550 0.55 none none Bug Screen Existing Right (N) 24.0 0.550 0.55 none none Bug Screen Altered Front (E) 70.1 0.550 0.55 none none Bug Screen Altered Left (S) 16.0 0.550 0.55 10.0 none Bug Screen Altered Left (S) 20.0 0.550 0.55 none none Bug Screen Altered Left (S) 50.7 0.550 0.55 none none Bug Screen Existing Rear (149 40.2 0.550 0.55 none none Bug Screen Altered Rear (tM 8.0 0.550 0.55 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Altered HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Altered Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins Altered EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2010-10-15708:45:58 ID: Page 3 of 16 LJ 0 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Fire Damage Repair -Hanson Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 11011512010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Split System includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC Altered incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2010-10-15T08:45:58 ID: Page 4 of 16 • • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Fire Damage Repair -Hanson Residence ❑ Multi Family m Existing+ Addition/Alteration 1101151201C ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 18.01 5.95 12.06 Space Cooling 110.70 105.07 5.63 Fans 22.35 26.17 -3.82 Domestic Hot Water 18.29 18.29 0.00 Pumps 0.00 0.00 0.00 Totals 169.35 155.48 13.87 Percent Better Than Standard: 8.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 340 70 Fuel Available at Site: Natural Gas (S) 517 87 Raised Floor Area: 0 (147 340 48 Slab on Grade Area: 1,569 (N) 517 56 Average Ceiling Height: 10.0 Roof 1,569 0 Fenestration Average U -Factor: 0.55 TOTAL: 261 Average SHGC: 0.55 Fenestration/CFA Ratio: 16.6% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 10/15/2010 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Paul Davis Restoration Address 77-833 Pa/adas Rd. Name Rod City/State/Zip Palm Desert, CA 92211 Phone (760) 360-1185 Signed License # Date knemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Pa e 5 of 16 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Fire Damage Repair -Hanson Residence Building Type IZI Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 0/15/201 OPAQUE SURFACE DETAILS Surface IU- Type I Area Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,569 0.032 R-30 0 0 Altered 4.2.1-A8 E=4.2.1 -A2 Fire Restoration Wall 461 0.102 R-13 0 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration Wall 250 0.102 R-13 90 90 Altered 4.3.1-A3 E=4.3. 1 -A1 Fire Restoration Door 20 1.450 None 90 90 Altered 4.5.1-A1 E=4.5.1 -A1 Fire Restoration Wall 430 0.102 R-13 180 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration Wall 292 0.102 R-13 270 90 Altered 4.3.1-A3 E=4.3.1 -A1 Fire Restoration Slab 1,569 0.730 None 0 180 Existing 4.4.7-A1 Fire Restoration FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 16.0 0.550 Default 0.55 Default 0 Existing Double Non -Metal Tint Fire Restoration 2 Window 16.0 0.550 Default 0.55 Default 0 Existing Double Non -Metal Tint Fire Restoration 3 Window 24.0 0.550 Default 0.55 Default 0 Altered Double Vinyl Tint Fire Restoration 4 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 5 Window 10.0 0.550 Default 0.55 Default 90 Altered Double Vinyl Tint Fire Restoration 6 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 7 Window 30.0 0.550 Default 0.55 Default 90 Altered Double Vinyl Tint Fire Restoration 8 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 9 Window 10.0 0.550 Default 0.55 Default 90 Altered Double Vinyl Tint Fire Restoration 10 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 11 Window 20.1 0.550 Default 0.55 Default 90 Altered Double Vinyl Tint Fire Restoration 12 Existing 0. 5501 Default 0.55 Default Double Non -Metal Tint pre -altered for above 13 Window 16.0 0.550 Default 0.55 Default 180 Altered Double Vinyl Tint Fire Restoration 14 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 15 JWndow 16.0 0.550 Default 0.55 Default 180 Altered Double Vinyl Tint Fire Restoration 16 1 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 6.7 6.0 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 6.7 6.0 10.0 0.1 10.0 10.0 15 JBug Screen 0.76 . 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2010-10-15T08:45:58 ID: Page 6 of 16 All • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Fire Damage Repair -Hanson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 0/15/201 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.550 Default 0.55 Default 180 Altered Double Vinyl Tint Fire Restoration 18 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 19 Window 10.5 0.550 Default 0.55 Default 180 Existing Double Non -Metal Tint Fire Restoration 20 Window 40.2 0.550 Default 0.55 Default 180 Existing Double Non -Metal Tint Fire Restoration 21 Window 40.2 0.550 Default 0.55 Default 270 Altered Double Vinyl Tint Fire Restoration 22 Existing 0.550 Default 0.55 Default Double Non -Metal Tint pre -altered for above 23 Window 8.0 0.550 Default 0.55 Default 270 Existing Double Non -Metal Tint Fire Restoration (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window Ove hanq Left Fin Ri ht Fin SHGC H t Wd Len HqL LEA REA Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number- 6712 RunCode: 2010-10-15T08:45:58 ID: Page 7 of 16 • • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Fire Damage Repair Hanson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 11011512010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC Altered Fire Restoration 1,569 15,690 1960 Totals 01 1,5691 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC Altered 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Altered pre -altered for above Central Furnace 75% AFUE Split Air Conditioner 8.9 SEER Setback HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Altered Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ New pre -altered for above Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas All Pipes Ins 40,000 50 0.58 n/a n/a Altered Standard Gas 50 gal or Le 1 Small Gas pre -altered for Above 1 40,000 50 0.58 1 n/a n/a MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E T w Hot Water Piping Length (ft)o c Q — System Name Pipe Len th Pipe Diameter Insul. Thick. 7QtyHP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5.1 by EnemySoft User Number 6712 RunCode: 2010-10-15T08:45:58 ID:Pa e 8 of 16 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name ire Damage Repair -Hanson Residence Date 11011512010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water'heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulatedper Standards Table 150-B. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunli ht moisture, equipment maintenance, and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Page 9 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date ire Damage Repair -Hanson Residence 11011512010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Li_qhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10.15708:45:58 ID: Page 10 of 16 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ire Damage Repair -Hanson Residence 10/15/2010 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. ' §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). Q1 50(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-15708:45:58 ID: Page 11 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ire Damage Repair -Hanson Residence Date 10/15/2010 System Name HVAC Altered Floor Area 1,569 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,378 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 25,453 1,909 540 26,864 Total Output Btuh 71,000 0 Output Btuh/s ft 45.3 2,158 1,909 Cooling System 0 0 Output perSystem 41,500 0 0 0 0 Total Output (Btuh) 41,500 2,480 1,909 -2,480 Total Output (Tons) 3.5 2,158 1,909 Total Output (Btuh/s ft) 26.4 Total Output s ft/Ton 453.7 32,249 28,201 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Split System 32,649 Total Adjusted System Output 32,649 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,943 71,000 3,943 71,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 0.89 Airflow cfm/Ton 404.8 Outside Air % 0.0% Air cfm/s ft 0.00 kHEATOutside : values above given at ARI conditions INGSYSTEM PSYCHROMETRICS Airstream Temperatures at Time of HeatingPeak 26 F -� Outside Air 0 cfm 69 OF 69 OF 116 OF 118 OF f (d aJ ► Supply Fan Heating Coil 117 OF 1,400 cfm ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 79/64°F 79/65°F 58/56°F 59/57°F Cooling Coil Supply Fan 61 / 57 OF 1,400 cfm 46.9% ROOM In 78/64°F EnergyPro 5,1 by EnergySoR User Number.' 6712 RunCode: 2010-10-15708:45:58 ID: Page 12 of 16 • • ROOM HEATING PEAK LOADS Project Name Fire Damage Repair -Hanson Residence Date 10/15/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Fire Restoration Floor Area 1,569.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT °F Btu/hr 0.0320 X 44 = 2,209 0.1020 X 44 = 6,431 0.5500 X 44 = 2,195 0.5500 X 44 = 4,121 1.4500 X 44 = 1,282 0.7300 X 44 = 6,296 `X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = another room Page Total 22,534 10.00 X 0.354 /60] X 44 = 4,330 Height ACH AT R-30 Roof 1,569.0 R-13 Wall 1,432.9 Double Non -Metal Tint 90.7 Double Vinyl Tint 170.3 Wood Door 20.1 Slab -On -Grade Perim = 196.0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,569 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 26,864 EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2010-10-15T08:45:58 ID: Page 14 of 16 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fire Damage Repair -Hanson Residence 1 10/15/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Fire Restoration Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 569.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF ODaaue Surfaces R-30 Roof R-13 Wall R-13 Wall Wood Door R-13 Wall R-13 Wall Orientation (N) (E) (E) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,569.0 0.0320 56.0 461.0 0.1020 23.0 249.8 0.1020 33.0 20.1 1.4500 33.0 430.31 0.1020 26.0 291.8 0.1020 33.0 0.0 31.4 30.0 64.1 0.0 31.4 10.0 64.1 0.0 31.4 20.1 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Window Existing Window Existing Window Altered Window Altered Window Altered Window Altered Window Altered Window Altered Window Altered OrIontation (N) (N) (N) (E) (E) (E) (E) (S) (S) Btu/hr 2, 812 1,082 841 141 j 7,8191 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 31.4 16.0 31.4 0.0 31.4 16.0 31.4 0.0 31.4 24.0 31.4 0.0 31.4 10.0 64.1 0.0 31.4 30.0 64.1 0.0 31.4 10.0 64.1 0.0 31.4 20.1 64.1 16.0 31.4 0.0 31.5 0.0 31.4 16.01 31.5 Page Total Btu/hr 503 503 754 641 1,922 641 1,288 503 7 Gain 5 4.0 Occupants X 230 Btuh/occ. Btu/hr- c 920 t 1.0 Dwelling Unit X 1,600 Btu 1,600 Infiltration: 1.064 X 0.87 X 97.15 X 34 = Air Sensible CFM ELA AT HEAT GAIN FOR Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 97.15 X 0.00276 = 1,109 Air Sensible CFM ELA AW 01 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fire Damage Repair -Hanson Residence 1 10/15/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Fire Restoration Outdoor Dry Bulb Temperature 112 OF Floor Area 1,569.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window Altered (S) 0.0 X 31.4 + 4.0 X 31.5 = 126 Window Existing (S) 0.0 X 31.4 + 10.5 X 31.5 = 331 Window Existing (S) 0.0 X 31.4 + 40.2 X 31.5 = 1,268 Window Altered (lM 0.0 X 31.4 + 40.2 X 64.1 = 2,575 Window Existing (lam 0.0 X 31.4 + 8.0 X 64.1 = 513 X + X - X + X - X + X - X +1 X - Page Total 4,813 Internal Gain Btu/hr Occu ants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 97.15 X 34 = 3,044 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,453 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 97.15 X 0.00276 = 1,109 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN,FOR ROOM 1,909 EneivvPro 5.1 by EnemySoft User Number: 6712 RunCode. 2010-10-15T08:45:58 ID: Pae 16 of 16