0304-339 (SFD)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
,Chkpter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full forceiand effect.
License # Lic. Class Exp. Date
r Date �� `f`Signature of Contractor •'��`"""�
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as thgir sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of. the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier S:"a >` �''vDl� is Policy No. C14tS-rel i+f+G :ta
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance ofIthe work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of Califo,'�nia, and agree that if I should become
subject to the workers' compensation2fprovisions Of Section 3700 of the Labor
Code, I shall forthwith comply with thAe provisions: -
Date: 44 Applicant
Warni g ' allure Z secure Workers'Compensation coverage is unlawful and
shall subject an employer to criminal enalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for. a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any. permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize° representatives of this City to enter upon
the above-mentioned property for 1 %'spection purposes.' r„
]Signature (Owner/Agent) 1''` Date I"
y .,
PERMIT PERMIT#
,.,BUILDING
DATE 'VALUATION LOTTRACT
JOB SITE
ADDRESS)(-�zs.iez2T�
APN
OWNER
CONTRACTOR / DESIGNER / ENGINEER
C^c3k77 J. PI-na Mk.,M)
h & M 0723` YR'':Ti,"IIS. N
79-025 VYA IS.rJ.iK` CL.ARA.
78-070 CALLS CADO
LA Q'Ubrr:A CA 922153
LA QTa'-3 rA CA. 9221123
626
N
USE OF PERMIT
A�YtiyyF*IMiLY q)tl1hZ_TYfVV
SFC '►q��,�:'A!if7'�1Dt1rZtZ NOT 1N Ci., Uw ? 61,06X W.i►U At; 0ti PA .
//1116t3+2yySy..F.�
p
Nli. L'rii.0 l`.0'Y.�4A LA���idi��. ¢•i.i .
TiiACT OcYYtJi•. UC:TION VIVO 0
PORC.KIPA 10 ' (AN ..r
QUAGMARPOWT 8F
yt'
J
,r
q7t TM MST 010 C0198'f RUC—ITON
K, Alh
IN)", 1.60
PLAMCHFI r1.Y.F3 $3361.13
ME y3?3.POSIT 101 -ON -45-9-318
r grKANICAI. ZFEE 101-f�}C.,-421-000 '; sp-ti?
FLW"f°ddC Al, PS Z SIS16. g1
t
Pi.tdMMATO FRE- 1(DI-000-419AVC? VS6,00
S` ROM) h9Ca;'lO1N ! FF, - "WO 101-000441-000 gt0,�t
��t�.RP14V01:��g:. : • ltii•�C�/.1-d�.3••fi1t�`Y�5.0�
DMMAMIN Ml3ACT FEE 'S2,405A
r PRFAA.�',Z K.AM $100, (to
...•f.�
1,Y tfyY+wY
f`15,Y t�t�T�•y, PLAN
hD�. B_11l`V3.1�'isa;.�VS�Ul�,lc�:Al.�.•�`LV.1,`I• AND Xd..AN F rAL` .0
1+ �•r
y6�yti��•. lJt3
1�L.1?MM4.'T'Ill" 1 WEV NOW
JUL 0 2 2003.
CITY OF LA t' m STA
d~
RECEIPT
DATE
,BY . ' 'r
[DATEJINALED
INSPECTOR
Q
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air -
Roof Deck
Exhaust Fans
O.K. to Wrap — Q
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover "
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines 3
Heater Final
,.Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans "
OX for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
_
Gas Test
Appliances
Final
Final:
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp., Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring..
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors 01
Temp.. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
CONCORDE CONSULTING GROUP, INC
3505 CAMINO DEL RIO SOUTH, # 350
SAN DIEGO, CALIFORNIA 92108
PHONE: 619/516-337 FAX: 619/516-3388
May 18, 2003
To:
Antonio Santa Maria
Santa Maria and Associates
44-100 Monterey Ave, # 201 B
Palm Desert, CA 92260
Re: Lots 20/22/23/19/21, La Quinta, California
Dear Antonio:
COPY, ,
This note is to confirm that the following substitutions can be made for shear walls with panels on both
sides; Please note that this will affect studs, top plates and sill plates.
Item # 1 — Use Type 9 shear wall instead of two sided Type 1 shear wall
Item # 2 — Use Type 12 shear wall instead of two sided Type 2 shear wall
Please call me if you have any questions v
Thanks
Kripanarayanan
f A No.
S2654
exp. a'03
0
�'F C
CONCORDE CONSULTING GROUP, INC.
ENGINEEERING & CONSTRUCTION MANAGEMENT
3505 CAMI.NO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PH: (619) 516-3377 FAX: (619) 516-3388
MEMORANDUM/FAX COVER SHEET
TO: FROM:
A & M CONSTRUCTION KRIPA
COMPANY: DATE:
09/02/03
FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER:
760/564-0406 1
PI-ION13 NUMBER: SENDER'S REFERENCE NUMBER:
YOUR REFERENCE NUMBER:
RE: SITE VISIT 8/27/03
X URGI7NT X FOR REVIEW X PLEASE COMMENT X PLEASE REPLY ❑ PLEASE RECYCLE
notes/Comments
PROJECT SITE ADDRESS: Lot # 7 — 51-665 Eisenhower Drive, La Quinta, California
THIS NOTE IS TO CONFIRM THAT SUBJECT TO THE CORRECTION OF THE FOLLOWING
ITEMS, THE FRAMING IS IN GENERAL CONFORMANCE WITH CONSTRUCTION
DOCUMENTS:
1. HOLDDOWNS APPEAR TO BE MISSING FROM THE SOUTH WALL OF EACH OF THE
HOUSES AT THE INTERIOR LOCATIONS. IF THESE ARE CALLED OUT, PLEASE USE
5/*" DIA ,;EPDXYED THREADED BARS WITH MINIMUM EMBEDMENT OF 6".
PROVIDE•SPECIAL INSPECTION FOR THIS WORK
2. THE GABLE TRUSSES OVER THE GARAGE ON THE EAST SIDE DOES NOT HAVE
CONNECTORS AT THE BEAM> PLEASE PROVIDE A35 AT 12" ON CENTER
3. THERE ARE SEVERAL AREAS WHERE THE TRUSSES HAVE NOT BEEN BLOCKED AT
THE TOP PLATE LINE. PLEASE ENSURE THAT THE BLOCKING IS COMPLETED AND
THERE A35 CONNECTORS (MINIMUM OF 1/BLOCK)
EXCEPT FOR THE ABOVE, FRAMING IS IN GENERAL C(
INTENT
THANKS
'r CONCORDE CONSULTING GROUP, INC.
ENGINEEERING & CONSTRUCTION MANAGEMENT
3505 CAMINO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PH: (619) 516-3377 FAX: (619) 516-3388
MEMORANDUM/FAX COVER SHEET
TO: FROM:
A & M CONSTRUCTION KRIPA
COMPANY:
DATE:
09/02/03
FAX NUMBER:
TOTAL NO. OF PAGES INCLUDING COVER:
760/564-0406
1
PHONE NUMBER:
SENDER'S REFERENCE NUMBER:
YOUR REFERENCE NUMBER:
RE: SITE VISIT 8/27/03
X URGENT X FOR REVIEW X PLEASE COMMENT X PLEASE REPLY ❑ PLEASE RECYCLE
notes/Comments
PROJECT SITE ADDRESS: Lot # 8 — 51-685 Eisenhower Drive, La Quinta, California
THIS NOTE IS TO CONFIRM THAT SUBJECT TO THE CORRECTION OF THE FOLLOWING
ITEMS, THE FRAMING IS IN GENERAL CONFORMANCE WITH CONSTRUCTION
DOCUMENTS:
1. HOLDDOWNS APPEAR TO BE MISSING FROM THE SOUTH WALL OF EACH OF THE
HOUSES AT THE INTERIOR LOCATIONS. IF THESE ARE CALLED OUT, PLEASE USE
5/*" DIA EPDXYED THREADED BARS WITH MINIMUM EMBEDMENT OF 6".
PROVIDE SPECIAL INSPECTION FOR THIS WORK
2. THE GABLE TRUSSES OVER THE GARAGE ON THE EAST SIDE DOES NOT HAVE
CONNECTORS AT THE BEAM> PLEASE PROVIDE A35 AT 12" ON CENTER
3. THERE ARE SEVERAL AREAS WHERE THE TRUSSES HAVE NOT BEEN BLOCKED AT
THE TOP PLATE LINE. PLEASE ENSURE THAT THE BLOCKING IS COMPLETED AND
THERE A35 CONNECTORS (MINIMUM OF 1/13LOCK)
EXCEPT FOR THE ABOVE, FRAMING IS IN GENERAL CONFO E"WITIISIGN
INTENT _ �Fc".�
THANKS r No• !r
$2654
�c Fxv
r•
CONCORDE CONSULTING GROUP, INC.
ENGINEEERING & CONSTRUCTION MANAGEMENT
3505 CAMINO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PH: (619) 516-3377 FAX: (619) 516-3388
MEMORANDUM/FAX COVER SHEET
TO: FROM:
A & M CONSTRUCTION KRIPA
COMPANY: DATE:
09/02/03
FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER:
760/564-0406 1
PHONE NUMBER:
RE: SITE VISIT 8/27/03
SENDER'S REFERENCE NUMBER:
YOUR REFERENCE NUMBER:
X URGENT X FOR REVIEW X PLEASE COMMENT X PLEASE REPLY ❑ PLEASE RECYCLE
notes/Comments
PROJECT SITE ADDRESS: Lot # 9 — 51-705 Eisenhower Drive, La Quinta, California
THIS NOTE IS TO CONFIRM THAT SUBJECT TO THE CORRECTION OF THE FOLLOWING
ITEMS, THE FRAMING IS IN GENERAL CONFORMANCE WITH CONSTRUCTION
DOCUMENTS:
1. HOLDDOWNS APPEAR TO BE MISSING FROM THE SOUTH WALL OF EACH OF THE
HOUSES AT THE INTERIOR LOCATIONS. IF THESE ARE CALLED OUT, PLEASE USE
5/*" DIA EPDXYED THREADED BARS WITH MINIMUM EMBEDMENT OF 6".
PROVIDE SPECIAL INSPECTION FOR THIS WORK
2. THE GABLE TRUSSES OVER THE GARAGE ON THE EAST SIDE DOES NOT HAVE
CONNECTORS AT THE BEAM> PLEASE PROVIDE A35 AT 12" ON CENTER
3. THERE ARE SEVERAL AREAS WHERE THE TRUSSES HAVE NOT BEEN BLOCKED AT
THE TOP PLATE LINE. PLEASE ENSURE THAT THE BLOCKING IS COMPLETED AND
THERE A35 CONNECTORS (MINIMUM OF 1/BLOCK)
EXCEPT FOR THE ABOVE, FRAMING IS IN GENERAL CONFO `NCE WIT,* ESIGN
INTENT ~ n\QASR
THANKS rNo* - ) *
* � W0m7
y CONCORDE CONSULTING GROUP, INC.
ENGINEEERING & CONSTRUCTION MANAGEMENT
3505 CAMINO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PH: (619) 516-3377 FAX: (619) 516-3388
MEMORANDUM/FAX COVER SHEET
TO: FROM:
A & M CONSTRUCTION KRIPA
COMPANY: DATE:
09/02/03
FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER:
760/564-0406 1
PHONE NUMBER: SENDER'S REFERENCE NUMBER:
YOUR REFERENCE NUMBER:
RE: SITE VISIT 8/27/03
X URGENT X FOR REVIEW X PLEASE COMMENT X PLEASE REPLY ❑ PLEASE RECYCLE
notes/Comments
PROJECT SITE ADDRESS: Lot # 10 — 51-725 Eisenhower Drive, La Quinta, California
THIS NOTE IS TO CONFIRM THAT SUBJECT TO THE CORRECTION OF THE FOLLOWING
ITEMS, THE FRAMING IS IN GENERAL CONFORMANCE WITH CONSTRUCTION
DOCUMENTS:
1. HOLDDOWNS APPEAR TO BE MISSING FROM THE SOUTH WALL OF EACH OF THE
HOUSES AT THE INTERIOR LOCATIONS. IF THESE ARE CALLED OUT, PLEASE USE
5/*" DIA EPDXYED THREADED BARS WITH MINIMUM EMBEDMENT OF 6".
PROVIDE SPECIAL INSPECTION FOR THIS WORK
2. THE GABLE TRUSSES OVER THE GARAGE ON THE EAST SIDE DOES NOT HAVE
CONNECTORS AT THE BEAM> PLEASE PROVIDE A35 AT 12" ON CENTER
3. THERE ARE SEVERAL AREAS WHERE THE TRUSSES HAVE NOT BEEN BLOCKED AT
THE TOP PLATE LINE. PLEASE ENSURE THAT THE BLOCKING IS COMPLETED AND
THERE A35 CONNECTORS (MINIMUM OF 1/BLOCK)
EXCEPT FOR THE ABOVE, FRAMING IS IN GENERAL CON%�_ 1RMANCE- � DESIGN
INTENT Z�QaNA�Ye.
THANKS Y
S22
6 6MO107
CONCORDE CONSULTING GROUP, INC.
ENGINEEERING & CONSTRUCTION MANAGEMENT
3505 CAMINO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PH: (619) 516-3377 FAX: (619) 516-3388
MEMORANDUM/FAX COVER SHEET
TO: FROM:
A & M CONSTRUCTION KRrPA
COMPANY: DATE:
09/02/03
FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER:
760/564-0406 1
PHONE NUMBER:
RE: SITE VISIT 8/27/03
SENDER'S REFERENCE NUMBER:
YOUR REFERENCE NUMBER:
X URGENT X FOR REVIEW X PLEASE COMMENT X PLEASE REPLY ❑ PLEASE RECYCLE
notes/Comments
PROJECT SITE ADDRESS: Lot # 11 — 51-735 Eisenhower Drive, La Quinta, California
THIS NOTE IS TO CONFIRM THAT SUBJECT TO THE CORRECTION OF THE FOLLOWING
ITEMS, THE FRAMING IS IN GENERAL CONFORMANCE WITH CONSTRUCTION
DOCUMENTS:
1. HOLDDOWNS APPEAR TO BE MISSING FROM THE SOUTH WALL OF EACH OF THE
HOUSES AT THE INTERIOR LOCATIONS. IF THESE ARE CALLED OUT, PLEASE USE
5/*" DIA EPDXYED THREADED BARS WITH MINIMUM EMBEDMENT OF 6".
PROVIDE SPECIAL INSPECTION FOR THIS WORK
2. THE GABLE TRUSSES OVER THE GARAGE ON THE EAST SIDE DOES NOT HAVE
CONNECTORS AT THE BEAM> PLEASE PROVIDE A35 AT 12" ON CENTER
3. THERE ARE SEVERAL AREAS WHERE THE TRUSSES HAVE NOT BEEN BLOCKED AT
THE TOP PLATE LINE. PLEASE ENSURE THAT THE BLOCKING IS COMPLETED AND
THERE A35 CONNECTORS (MINIMUM OF 1/BLOCK)
EXCEPT FOR THE ABOVE, FRAMING IS IN GENERAL
INTENT
THANKS
DESIGN
/off@�QpNARgy9,tq
y
No.
60ro7
STRUCt��P�
c" �
STA7t nc ^ `•
Certificate of Occupancy
P
�
j10 �1A4D�
c� Safet artment
& Department
�.�w
of 9► Y p
b
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in _compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
f
construction and/or use.
BUILDING ADDRESS: 51-665 EISENHOWER DRIVE
P
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 0304-339
Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RC
'i
Owner of Building: CHRISTOPHER LLOYD Address: 79-025 VIA SAN CLARA
City, ST, ZIP: LA QUINTA, CA 92253
By: KIRK KIRKLAND
a't-, Date: November 3, 2003
Building Official
L
C
POST IN A CONSPICUOUS PLACE s