9512-125 (SFD)- P • LICENSED CONTRACTOR DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with
r W Section 7000) of Division 3 of the Business and Professionals Code, and my
License is in full force and effect. /�
o W^ License # L 16,1ass a. Date/ 3 t
ZDate SignatureofContractor• Ti_.
coo IN
P 0)- OWNER -BUILDER DECLARATION
J W I hereby affirm that I am exempt from the Contractor's License Law for the
d following reason:
Z ( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
() I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals Code).
( ) I am exempt under Section , B&P.C. for this reason
C0 Date Signature of Owner
N
rn WORKER'S COMPENSATION DECLARATION
FL Q I hereby affirm under penalty of perjury one of the following declarations:
"F Z ( ) I have and will maintain a certificate of consent to self -insure foi workers'
15 HO cc compensation, as provided for by Section 3700 of the Labor Code, for the
W Lu performance of the work for which this permit is issued.
D J J () I have.and will maintain workers' compensation insurance, as required by
n Q U Section 3700 of the Labor Code, for the performance of the work for which this
J U permit is issued. My workers' compensation insurance carrier & policy no. are:
LLo gCarrierPolicy No.
It ? (This sectio ' 'not a completed if the permit valuation`is for $1'60.00 or less).
r- a() I certify that in the performance of the work for which this permit is issued,
C1 I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
o Code, I shall forthwith comply with those visions.
o /Date: (Appliw, "' _ e =
Warning: Failure to secure Worker Cop ation coverage is unlawful and shall
subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this application agrees to, & shall, indemnify
& hold harmless the City of Indian Wells, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
114 work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon the
'• above-mentioned property for insp�bction purposes.
Signature (Ow Agent) / Date
ALC '
BUILDING PERMIT
PERMIT9����
DATE itn/96
VALUATION �����1(6.� LOT $ TRACT {, _ .i1T
JOB SITE ADDRESS
APN
51-770 %XSrN'.MOWER OR.
OWNER
CONTRACTOR
MV11CONsTRC.0 ION
Leucxuard'R!i. Meier
'0170291 .OQUi.IS:D .
USE OF PERPAT WOL .I AJVII1: VD WELLING
Peamit do" not include block, WAI-Is or pool.
FEE DESCRIPTION
FEES
TRAC P C014STt2ilMON LZI.00 Sr
1}U€Lt,R-IIPA'!: (O 28.00 SF
tit1RA.GEi'r-'AftPtiF. T 420.JJI Sr
I ST1rMeb.'1'I D ICOKf OF CONS'. RUCTION
94.416.60
PERMIT FEC SUMMARY
'$n+ +0:00 .
PLAN Cf lk.CK FEE 10140.439-318 $5x.84
CONST UC71 0111E 101-000.418-000 $st7.u0
T "[i.KNICAL.'tFstd $53,50
IRLEMIC,At, FSE 101-00()-;1204M 0 $17q 24
I=.I TJM13I[NC. FEE 401.000419.000 $148.00
:'i'vl G .M'OTION FEC • WRS0 1001 000-21;1.060 $9A4
C�P.A17tI4G'FkS� 101-M)0-42'4-000
INFRASTRIR"I't. RE FER 22,5-0004143,342
P:;��.ISI TAL N $25.00
SUB -TOTAL C ONST.RUC' ON AND KtLN Cli1~CK
.,-• LESS i'1 E-PA.1D FEES
AL :l.'E.i4ATIT ME S DIJl NOW
$3;5611.'19
42.50.00
$3,348.19
r .,
✓qA( 2
� 1996P/
[RECEIPT
DATE
BV
DATE FINALED
INSPECTOR
a..
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APP OVALS
MECHANICAL APPROVALS
Set Backs /.
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing Zj
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath Q
Final
Final /
BLOCKWIALL APPROVALS
POOLS s SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
;Gas Pi ng .
_. PLUMBING APPROVALS
'ca's`Test �;"
ZRIectric Phial ;`:
Waste Lines A
HehtarF Final {,
Water Piping ..
;Plumbing Final
Plurribing TAp Out
"Equipment Enclosure _
Shower Pans
"OK� for Finish Plaster
Sewer Lateral
• Pool Cover
Sewer Connection
(Encapsulation
Gas:.�iping,. ,. S.
Gas Test
Appliances.
Final -
E _
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
r"
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final .
Utility Notice (Perm)
COMMENTS:4
Building
Address .<-t— 770
Owner
c&ty,, 4 4a,Q"
- - .
P.O. BOX 1504 APPLICATION ONLY
78-105 CALLE ESTADO
G 57 'W Ir".&A QUINTA, CALIFORNIA 92253
Mailing
Address ""
CityZip
Address
Zip —17el.
State Lic. City
& Classif. I Lic. #
Arch., Engr.,
Designer
Address Tel.
City IZip I State I
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I am licensed under provisions of -Chapter 9 (commencing with Section
the Business and Pr6fessions Code,and,mv license is in full force and
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than live hundred dollars ($500).
l; I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
I 1 I am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
r7 Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: It, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives sof this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING DIVISION
BUILDING: TYPE CONST. -7 OCC: GRP.
A.P. Number ` DO
Legal Description 614Z Zd2t
Description
Sq. Ft. No. No. Dw.
Size Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
PERMIT
AMOUNT
Plan Chk. Dep.
yOr00
Plan Chk. Bal.
�
Date�Permit \ I I
Const.
Validated by:
Validation:
Validation:
Mech.
IJ r' r� n •�,�-
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE—INSPECTOR—
ATEINSPECTOR-"-'
Issued
Issued by:
�
Date�Permit \ I I
rr
Fr
Validated by:
Validation:
Validation:
IJ r' r� n •�,�-
71
1
LUQ
1V
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SO. FT. @ $
UNITS
SLAB GRADE
2ND FL. SQ. FT. 0
BONDING
Y
ARD SPKLR SYSTEM
POR. SQ. FT. @
MOBILEHOME SVC.
BAR SINK
GAR. SO. FT. @
POWER OUTLET
ROOF DRAINS
FOUND. REINF.
GAS (ROUGH)
DRAINAGE PIPING
CAR P. SQ. FT. 0
OTHER APP./EQUIP.
REINF. STEEL
WALL SO. FT. 0
TEMP. POLE
DRINKING FOUNTAIN
SQ.;FT. 0
GROUT
URINAL
ESTIMATED CONSTRUCTION VALUATION $
FINAL INSP.
WATER PIPING
NOTE: Not to be used.as property tax valuation
WATER SYSTEM
FLOOR DRAIN
MECHANICAL FEES
_$
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRYTRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM. B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. @ c
BATH TUB
SPARK ARRESTOR
SQ. FT. @ c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID 0 1 I c
SEWAGE DISPOSAL
LATHING
SQ.FT.GAR 0 V c
HOUSE SEWER
MESH
GAS PIPING
PERMIT FEE
INSULATIONISOUND
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE MECH.FEE
PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING R AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APP./EQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
REMARKS:
VENTILATION
--
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL_ FINAL 7d
Notice:
Document Cannot Be Duplicated
Date 1/22/96
Desert Sands Unified School District
82-879 Highway 111
Indio, CA 92201
619-775-3500
CERTIFICATE OF COMPLIANCE
No, 14073 Jurisdiction
Owner Name Leonard Meier
No. 51770 street Eisenhower Drive
City La Quinta Zip 92253
APN # 773-175-001
La Quinta
Permit #
Log #
Study Area 113
Tract # Lot # Square Footage 1524
Type of Development Single Family Residence No. of Units 1
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet, detached
accessory structures or replacement mobilehomes. It has been determined the above-named owner is
exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 1.72 X 1,524 or $2,621.28
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
v
Fees Paid By Leonard & Barabara Meier ; 'Ji4plfone-,-
Name on the check s� `
By Dolores A. Ballesteros
Superintendent j,
Fee collected /exempted by Pauline Pearson Payment Received $2,621.28
W � M� M. . NEWS. , v �'a
Check No. 687
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Com - Accounting
Carole Christensen, Analyst
Title -24 Energy Calculations April 15, 1996
F
ENERGY CALCULATIONS FOR:
Leonard Meier
77-029 Iroquois Drive
Indian Wells, CA 92210
PROJECT: ' Meier Residence
1524 sq.ft. Custom Home
La Quinta, CA 92253
Standard Proposed Compliance
49.57 48.11 +1.46
FINAL CALCULATION
West Orientation
Dual Aluminum glazing, Default U -values, V.Blinds, Lt.(Std Drape on French doors)
Walls R-13, Roof R-38 Duct R-4
AFUE 78%, SEER 10.0
One 40 gal gas water heater, EF .57
Table of Contents
CF -1R
MF -1R
C -2R
3-R
HVAC
47-596 Lake Canyon Drive, Aguanga, CA 92536
1-800-735-8152
Member CABEC - California Association of Building Energy Consultants
t
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Protect Title.......... Meier Residence Date........ 04/15/96
Project Address........ *******
La Quinta CA *v4.50*
Documentation Author... Carole Christensen *******
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
,Climate Zone.. ..... 15
Building Perini
Plan Check Da e
Fie Check/ Date
Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
GENERAL INFORMATION
Conditioned Floor Area..... 1524 sf
Building Type .............. Single Family Detached
Construction Type ... New
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Stories... ...... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 15 % of floor area
Average Glazing U -value.... 0.82 Btu/hr-sf-F
BUILDING SHELL INSULATION
Component
Frame
Cavity Sheathing Assembly
Type
Type
R -value
R -value U -Value
Location/Comments
Wall
Wood
R-13
R-0
0.088
front, right, back, left
Wall
Wood
R-13
R-0
0.086 'to
garage
Roof
Wood
R-38
R-0
0.034
attic
Door
n/a
R-0
R-n/a
0.330
solid wood
S1abEdge
n/a
R-0
R-n/a
0.720
to outside
S1abEdge
n/a
R-0
R-n/a
0.550
to garage
'SlabEdge
n/a
R-0
R-n/a
0.500
to garage
FENESTRATION
# of
Interior
Over -
Area
U- Pan-
Shading/
Exterior
hang/
Framing
Orientation
(sf)
Value es
Description
Shading
Fins
Type
Window
Front
(W),
24.0
0.870 2
Blinds.Lt
None
None
Metal
Window
Right
(S)
28.0
0.870 2
Blinds.Lt
None
None
Metal
Door
Right
(S)
33.3
0.770 2
Drapes.Std
Bldg Shade
None
Metal
Door
Back
(E)
73.3
0.770 2
Drapes.Std
Bldg Shade
None
Metal
Window
Back
(E)
2.0
0.870 2
Blinds.Lt
None
None
Metal
Window
Left
(N)
57.0
0.870 2
Blinds.Lt
None
None
Metal
Window
Left
(N)
10.5
0.870 2
Blinds.Lt
Bldg Shade
None
Metal
1
Carole Christensen, Analyst
Title -24 Energy Calculations
ENERGY CALCULATIONS FOR:
Leonard Meier
77-029 Iroquois Drive
Indian Wells, CA 92210
PROJECT: Meier Residence
1524 sq.ft. Custom Home
La Quinta, CA 92253
�. Standard Proposed
49.57 49.34
West Orientation
Dual Aluminum glazing, V.Blinds; Lt.
Walls R-13, Roof R-38 Duct R-4
AFUE 78%, SEER 10.0
One 40 gal gas water heater, EF .55
Table of Contents
CF -IR
WAR
C -2R
3-R
HVAC
CF -6
IC -1
Fenestration Specifications
IVs' 012� rr<
'V'- 10 sw""'
a � 60y
c
Ve �
Compliance
+ 0.23
47-596 Lake Canyon Drive, Aguango, CA 92536
1-800-735-8152
Member CABEC - California Association of Building Energy Consultants
q�'
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... Meier Residence Date........ 01/29/96
*******
Project Address........
La Quin a CA *v4.50*
Documentation Author... Carole Christensen *******
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
Climate Zone 15
Building Permit
Plan Check Date
Field Check/ Da e
Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
GENERAL INFORMATION
• Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -value....
1524 sf
Single Family Detached
New
Front Facing 270 deg (W)
1
1
Slab On Grade
15 % of floor area
0.76 Btu/hr-sf-F
BUILDING SHELL INSULATION
Component
Frame
Cavity Sheathing Assembly
Type
Type
R -value
R -value U -Value
Location/Comments
Wall
Wood
R-13
R-0 0.088
front, right, back, left
Wall
Wood
R-13
R-0 0.086
to garage
Roof
Wood
R-38
R-0 0.034
attic
Door
n/a
R-0
R-n/a 0.330
solid wood
S1abEdge
n/a
R-0
R-n/a 0.720
to outside
S1abEdge
n/a
R-0
R-n/a 0.550
to garage
S1abEdge
n/a
R-0
R-n/a 0.500
to garage
FENESTRATION
# of Interior
Over -
Area
U- Pan- Shading/
Exterior
hang/ Framing
Orientation
(sf)
Value es Description Shading
Fins Type
Window Front
(W)
24.0
0.750 2 Blinds.Lt
None
None Metal
Window Right
(S)
28.0
0.750 2 Blinds.Lt
None
None Metal
Door Right
($)
33.3
0.770 2 Blinds.Lt
Bldg Shade
None Metal
Door Back
(E)
33.3
0.770 2 Blinds.Lt
None
None Metal
Window Back
(E)
2.0
0.750 2 Blinds.Lt
None
None Metal
Door Back
(E)
40.0
0.770 2 Blinds.Lt
Bldg Shade
None Metal
Window Left
(N)
57.0
0.750 2 Blinds.Lt
None
None Metal
Window Left
(N)
10.5
0.750 2 Blinds.Lt
Bldg Shade
None Metal
I
THERMAL MASS
Area Thickness
Type
Exposed
(sf) (in)
Location/Comments
S1abOnGrade
Yes
487 3.5
Ent.kitdin.morn.bath.hal
S1abOnGrade
No
1037 3.5
framing/cabinets/carpet
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
HVAC SYSTEMS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications' needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
Name.... Leonard Meier
Company. Owner/Builder
• Address. 77-029 Iroquois Dr.
Indian Wells, CA 92210
Phone... (619) 345-7266
License.
Signed..
( a e
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
date
DOCUMENTATION AUTHOR
Name.... Carole Christensen
Company.
Address. 47-596 Lake Canyon Drive
Aguanga, CA 92536
Phone... 800-735-8152
Signed..
( a e)
Minimum Duct
Duct
Thermostat
Equipment Type
Efficiency Location
R -value
Type
Furnace
0.780 AFUE Attic
R-4
Setback
ACSplit
10.00 SEER Attic
R-4
Setback
WATER HEATING SYSTEMS
Number
Tank
External
'
in Energy Size
Insulation
Tank Type Heater
Type Distribution Type
System Factor (gal)
R -value
Storage Gas
Standard
1 0.55
EF 40
R-12
SPECIAL FEATURES/REMARKS
Milgard fenestration
U -values or better.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications' needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
Name.... Leonard Meier
Company. Owner/Builder
• Address. 77-029 Iroquois Dr.
Indian Wells, CA 92210
Phone... (619) 345-7266
License.
Signed..
( a e
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
date
DOCUMENTATION AUTHOR
Name.... Carole Christensen
Company.
Address. 47-596 Lake Canyon Drive
Aguanga, CA 92536
Phone... 800-735-8152
Signed..
( a e)
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance
approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features
noted shall be considered by all parties as binding minimum component performance specifications for the
mandatory measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION
Building Envelope Measures
" §150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
* §150(c): Minimum R-13 wall Insulation in framed walls (does not apply to exterior mass walls).
* §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors.
§150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 permfinch.
.§118: Insulation specified or installed meets California Energy Commission quality standards.
Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and InfiltralJon/Exliltration Controls
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenesUation products have label with cerlified U=value, and infiltration certification.
c. Exterior doors and windows weathersUipped; all joints and penetrations caulked and sealed.
§150(s): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with §151 meets Commission quality standards.
§150(e): Inslailation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(i): Setback thermostat on all applicable heating systems.
§150Q): Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. First 5 feet of pipes closest to water healer tank, non -recirculating systems, insulated (R•4 or greater).
3. All buried or exposed piping insulated in redreulating sections of hot water system.
4. Cooling system piping below 55°F Insulated.
5. Piping insulated b0ween healing source and indirect hot water tank.
* §150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4,2 or ducts enclosed entirely within conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers..
§114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
no electric resistance heating and no pilot light.
2. System Is installed with:
a. At least 36' pipe between filter and heater for future solar heating,
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional Inlets and acirculation pump time switch.
§115: Gas-fired central furnace, pool healer, spa heater or household cooking appliance have no
continuously buring pilot light. (Exception: Non-elecVical cooking appliance with pilot < 150 Blu/hr.)
Lighting Measures
§150(k): 40 lumenshvalt or greater for general lighting In kitchens and rooms with water closets; and
recessed ceiling fixtures IC (insulation cover) approved.
DESIGNER I ENFORCEMENT
Compliance Forms
January 1, 1995
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... Meier Residence Date........ 01/29/96
A *******
Project A dress........
La Quin a CA *v4.50*
Documentation Author... Carole Christensen *******
Climate Zone...
Compliance Metk
MICROPAS4 v
U
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
15
Building Permit
Plan Check DaTe
Field Check/ Da e
..... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
4 50 File-MEIER08W Wth-CTZ15S92 Program -FORM C -2R
s #-MP1017 User- Run-DrpFau78AC10.OR13.38.4
MICROPAS4 ENERGY USE SUMMr
Y
Energy Use Standard Pr posed Compliance
(kBtu/sf-yr) Design esign Margin
Space Heating... ..... 2.84/De
3.22 -0.38
Space Cooling.... .... 32.6932.51 0.18
Water Heating..... ... 14.0413.61 0.43
To 1 49.5749.34 0.23 l
*** Building compl'es with Car Performance
1
GENERA INFO TION
Conditioned Floor Area.... 1524 sf
Building Type .............. Single Family Detached
Construction Type ......... ew
Building Front Orientation. ont Facing 270 deg (W)
Number of Dwelling Units.. 1
Number of Building Storie 1
Weather Data Type........ . Redu dYear
Floor Construction Type. Slab On Grade
Number of Building Zone ... 1
Conditioned Volume..... ... 12344 cf
Footprint Area........ ... 1524 sf
Ground Floor Area..... .... 1524 sf
Slab -On -Grade Area......... 1524 sf
Glazing Percentage... ..... 15.% of floor rea
Average Glazing U-va e.... 0.76 Btu/hr-sf-
Average Ceiling Hei t..... 8.1 ft
BUI ING ZONE INFORMATION
Floor # of Vent Special
Area Volume Dwell Cond- Thermostat ight Vent Area
Zone Type (sf) (cf) Units itioned Type ft) (sf)
HOUSE
Residence 1524 12344 1.00 Yes Setback 2.0 n/a
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
OPAQUE SURFACES
PERIMETER LOSSES
Length
F2 11Rsu
-
Insul
Act
Surface
Solar
Form 3
Location/
Surface
Slider 0.750 180
lue�R-val
0.88
Azm
Tilt
Gains
Reference
Comments
HOUSE
outside
.88
13 S1abEdge
3
0.550 -0
No to
garage
Slider 0.770 180
1
Wall
0.500 R-0
.088
13
270
90
No
W.13.2X4.16
front
2
Wall
# of
.088
13
270
90
Yes
W.13.2X .16
front
3
Wall
Shading/
088
13
180
90
Yes
W.13.2 4.16
right
4
Wall
90
. 88
\_e
13
180
90
No
W.13 X4.16
right
5
Wall
_58
.0 8
13
90
90
Yes
W. .2X4.16
back
• 6
Wall
17.
.08
13
90
90
No
W 3.2X4.16
back
7
Wall
.088
3
0
90
No
.13.2X4.16
left
8
Wall
088
0
90
Yes
W.13.2X4.16
left
9
Wall
086
1
270
90
NoW.13GAR
to garage
10
Roof
4.Door
.034
38
n/a
0
Y
R.38.2X4.24F
attic
11
Door
40.0 Bldg Shade
.330
0
270
90
o
None
solid wood
PERIMETER LOSSES
HOUSE
1 Window
2 Window
3 Window
4 Door
5 Door
6 Window
7 Door
8 Window
9 Window
10 Window
11 Window
24.0
Length
F2 11Rsu
Solar
9`
0.88
Surface
(ft)'
Factor R-
Gains Location/Comments
HOUSE
Slider 0.750 180
90
0.88
0.58
Blinds.Lt
12 S1abEdge
163
0.720 0
No to
outside
.88
13 S1abEdge
3
0.550 -0
No to
garage
Slider 0.770 180
14 S1abEdge
33
0.500 R-0
No to
garage
2
etal
Slider 0.770 90
FENE-TRATION SUR, CES
0. 8
0.58
Blinds.Lt
# of
Vent
Metal
SC SC
Interior
Area
Pan- Frame
Open U-
Ac
Glass Int
Shading/
Surface (sf)
es Type
Type value Azm Tlt Only Shade
Description
HOUSE
1 Window
2 Window
3 Window
4 Door
5 Door
6 Window
7 Door
8 Window
9 Window
10 Window
11 Window
24.0
2
Met
Slider 0.750 270
9`
0.88
0.58
Blinds.Lt
14.0
2
MetAl
Slider 0.750 180
90
0.88
0.58
Blinds.Lt
14.0
2
Me al
Slider 0.750 180
90
.88
0.58
Blinds.Lt
33.3
2
M tal
Slider 0.770 180
90
0 88
0.58
Blinds.Lt
33.3
2
etal
Slider 0.770 90
90
0. 8
0.58
Blinds.Lt
2.0
2
Metal
Slider 0.750 90
90
0.8
0.58
Blinds.Lt
40.0
2
Metal
Slider 0.770 90
90
0.88
0.58
Blinds.Lt
20.0
2
Metal
Slider 0.750 0
90
0.88
.58
Blinds.Lt
20.0
Metal
Slider 0.750 0
90
0.88
_58
Blinds.Lt
10.5
2
Metal
Slider 0.750. 0
90
0.88
0.58
Blinds.Lt
17.
2
Metal
Slider 0.750 0
90
0.88
0.58
Blinds.Lt
EXTERIOR SHADING
Area Shading
SC of
Surface
(sf) Type
Ext Shade
HOUSE
4.Door
33.3 Bldg Shade
0.20
7 -Door
40.0 Bldg Shade
0.20
10
Window
10.5 Bldg Shade
0.20
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
System Type \
HOUSE
Furnace
ACSplit
Minimum Duct
Efficiency Location
0.780 AFUE Attic
�ATER
00 SEER Attic /
HEATING SYSTEM
Duct
Duct
-value
THERMAL MASS
R-4
0.825
Area
Thick
Heat Conduct- Surface
Type Distribution Type System
Mass Type
(sf)
(in)
Cap ivity R -value
Locatio /Comments
HOUSE
SPECIAL EAT 7ES/REMARKS
7
1 S1abOnGrade
487
3.5
28.0 0.98 R-0.0
Ent.k,tdin.morn.bath.hall
2 S1abOnGrade
1037
3.5
28.0 0.98 R-2.0
framing/cabinets/carpet
HVAC SYSTEMS
/
System Type \
HOUSE
Furnace
ACSplit
Minimum Duct
Efficiency Location
0.780 AFUE Attic
�ATER
00 SEER Attic /
HEATING SYSTEM
Duct
Duct
-value
Efficiency
R-4
0.825
R-4
0.803
umber
Tank
External
in
Energy Size
Insulation
Tank Type Heater.
Type Distribution Type System
Factor (gal)
R -value
1 Storage. Gas
Standar1
0.55 40
R-12
SPECIAL EAT 7ES/REMARKS
Milgard fenestration
U -values or bett r.
CONSTRUCTION ASSEMBLY Page 1 3R
Project Title.......... Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
Parallel Path Method
Reference Name W.13.2X4.16
Description .... Wall R-13 2x4 16oc
Type ........... Wall
R -Value 13 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type ..... Wood
Description .. 2x4 fir
Spacing ... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Name Description
0. FILM. EX
1. STUCCO.0.88
2. BLDG.PAPER
3c. BATT.R13
3f. FIR.2X4
4. GYP.0.50
I. FILM.IN.WLL
Exterior air film: winter value
0.875 in stucco
Building paper (felt)
R-13 batt insul (cavity = 3.5 in)'
2x4 fir
0.50 in gypsum or plaster board
Inside air film: heat sideways
FRAMING ADJUSTMENT CALCULATION
Cavity
Cavity
Frame
R -Value
R -Value
0.17
0.17
0.17
0.17
0.06
0.06
13.00
--
--
3.46
0.45
0.45
0.68
0.68
Total Unadjusted R -Values 14.53
7
Framing Total
U -Value: (1 / 14.53 X-0.85) + (1 / 5.00 x 0.15) _
Total R -Value: 1./ 0.088 =
0.088 Btu/hr-sf-F
11.30 hr-sf-F/Btu
5.00
CONSTRUCTION ASSEMBLY Page 2 3R
Project Title ........>. Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
Parallel Path.Method
Reference Name . W.13GAR
Description .... Wall R-13 2x4 16oc
Type ........... Wall
R -Value ......... 13 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type .... Wood
Description .. 2x4 fir
Spacing .... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Total R -Value: 1 / 0.086 ,= 11.58 hr-sf-F/Btu
Material
Cavity
Frame
Name
Description
R -Value R
-Value
O.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
3c.
BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
3f.
FIR.2X4
2x4 fir
--
3.46
-4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values
14.75
5.21
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value: (1 / 14.75 x 0.85) + (1 / 5.21 x 0.15)=
0.086 Btu/hr-sf-F
Total R -Value: 1 / 0.086 ,= 11.58 hr-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 3 3R
Project Title.......... Meier Residence Date........ 01/29/96
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
Parallel Path Method
Reference Name . R.38.2X4.24F
Description .... Roof R-38 2x4 24oc
Type ........... Roof
R -Value ........ 38 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type ......... Wood
Description .. 2x4 fir
Spacing .... 24 inches on center
Framing Frac.. 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value R
-Value
0.
FILM.EX
Exterior air film: winter
value
0.17
0.17
1.
BUILTUP.0.38
0.375 in built-up roofing
0.33
0.33
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.0.50
0.5 in (approx) air space:
heat
flow up
0.73
0.73
5c.
BATT.R38.0
R-38 batt insul (cavity >
11.25
in)
38.00
--
5f.
FIR.2X4
2x4 fir
--
3.46
7.
GYP.0.50
0.50 in gypsum or plaster
board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow
straight up
0.61
0.61
Total Unadjusted
R -Values
40.97
6.43
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value:
(1 / 40.97
x 0.93) + (1 / 6.43 x
0.07)
= 0.034
Btu/hr-sf-F
Total
R -Value:
1 /
0.034
= 29.78
hr-sf-F/Btu
HVAC SIZING Page 1 HVAC
Project Title.......... Meier Residence
Project Address........ *******
La Quin a CA *v4.50*
Documentation Author... Carole Christensen *******
.47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
Climate Zone 15
Date........ 01/29/96
Bui ding.Permit
Plan Check Date
Field Check/ Da e
Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User- Run7DrpFau78AC10.OR13.38.4
GENERAL INFORMATION
FloorArea .................
Volume.. ..... ...........
Front Orientation....... .
Sizing Location............
Latitude... .. .. .......
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range.. ......
Interior Shading Used... .
Exterior Shading Used....`..
Overhang .Shading Used......
Latent Load Fraction.......
Description
1524 sf
12344 cf
Front Facing 270 deg
INDIO
33.7 degrees
29 F
70 F
112 F
78 F
30 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
(Btuh)
Opaque Conduction and Solar...... 12775
Glazing Conduction ............... 7103
Glazing Solar .................... n/a
Infiltration ..................... 7279
Internal Gain .................... n/a
Ducts ............................ 2716
Sensible Load .................... 29873
Latent -Load ...................... n/a
Cooling
(Btuh)
6306
5891
7836
4314
2550
2690
29586
. 5917
Minimum Total Load 29873, 35503
(W)
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc.', must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
INSTALLATION CERTIFICATE (page 1 of 4) CF -6R
Site Address Permit Number
An installation certificate is required to be posted at the building site or made available for all appropriate
inspections. (The information provided on this form is required; however, use of this form to provide the
information is optional.) After completion of final inspection, a copy must be provided to the building
department (upon request) and the building owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
Equip. # of Efficiency Duct Duct or Heating Heating
Type (pkg., CEC Certified Mfr Name Identical (AFUE, etc.) Location Piping Load Capacity
heat Dump) & Model Number Systems f>_CF- 1R value] (attic. etc.) R -value (Btu/hr) (Btu/hr)
Cooling Equipment
Equip. CEC Certified Compressor # of Efficiency Duct Cooling Cooling
Type (pkg., Unit Mfr Name and Identical (SEER, etc.) Location Duct Load Capacity
heat pump) Model Number Systems f z CF -1 R value] (attic.etc.) R -value (Btu/hr) (Btu/hr)
I, the undersigned, verify that equipment listed above my signature (1) is the actual equipment installed; (2) is equivalent
to or more efficient than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with the
Energy Efficiency Standarels for residential buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date Installing Subcontractor (Co. Name)
OR General Contractor (Co. Name) OR Owner
WATER HEATING SYSTEMS:
Distribution If Recir- # of Rated'. Tank Effi- External
Heater CEC Certified Mfr Type (Std, culation, Identical Input (kW Volume ciency' Standby' Insulation
Type Name & Model Number Point -of -Use) Control Type Systems or Btu/hr) (gallons) (EF. RE) Loss M R -value
' For small gas storage (rated input 5 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input > 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input.
For instantaneous gas water heaters, list Recovery Efficiency and Rated Input.
Faucets & Shower Heads:
All faucets and showerheads installed are certified to the Commission, pursuant to Title 24, Part 6,
Subchapter 2, Section 111.
I, the undersigned, verify that equipment listed above my signature (1) is the actual equipment installed; (2) is equivalent
to or more efficient than'that specifieif in�the'ceitificate of -compliance (Form CF -1R) submitted for compliance with the
Energy Efficiency Stdndards,for,iesulential°buildings; and (3) the equipment meets or exceeds the appropriate
requirements for manufactured devices (froth the Appliance Efficiency Regulations or Part 6), where applicable.
Signature, Date
COPY TO: Building Department
Building Owner at Occupancy
Compliance Forms
Installing Subcontractor (Co. Name) OR
General Contractor (Co. Name) OR Owner
July 1, 1995
INSTALLATION CERTIFICATE (page.2 'of 4) . CF -6R
Site Address -Permit Number
FENESTRATION/GLAZING:
Operator
Type (e.g.,
(fixed,
Manufacturer/Brand Name slider)
Manufactured
Products
Labelled Site Built Products
U -value (s # of Default
CF -1 R value)2 Panes U-Value2
' • _
Total
Quantity Square Comments/
(Opt/onan Feet Special Features
(GROUP LIKE PRODUCTS)
2.
3.
4.
S.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
2 Installed U -value must be less than or equal to value from CF -1R. Alternatively, installed weighted
average U -value for the total fenestration area is less than or equal to value from CF -1R.
1, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product
installed; (2) is equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1R)
submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product, meets or
exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable.
Item #s
(if applicable)
Signature, Date
Item #s Signature, Date
(if applicable)
Item #s Signature, Date
(if applicable)
COPY TO: Building Department
Building Owner at Occupancy
Installing Subcontractor (Co. Name) OR
General Contractor (Co. Name) OR Owner
Installing Subcontractor (Co. Name) OR
General Contractor (Co. 'Name) OR Owner
Installing Subcontractor (Co. Name) OR
General Contractor (Co..Name) OR Owner
Compliance Forms July 1, 1995
INSTALLATION CERTIFICATE (page 3 of 4
e following is an exp anation o many of tFTe input values required on this orm:
HVAC SYSTEMS
Heating Equipment Type must be one of the following:
Furnace:
Gas or oil -fired central furnace & space heater
Boiler:
Gas or oil -fired boiler
PckgHeatPump:
Packaged central heat pump
SplitHeatPump:
Split central heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (z 65,000 Btu/hr output)
Electric:
Electric resistance heating (fixed HSPF = 3.413); radiant electric
resistance (fixed HSPF = 3.55)
CombinedHydro:
Reference water heater under water heating systems below
CF -6R
CEC Certified Manufacturer Make & Model Number from applicable CEC approved appliance directory.
It of Identical Systems is for those systems with the same efficiency, duct location, duct R -value and
capacity.
Efficiency from applicable CEC approved appliance directory.
Duct Location is attic, crawlspace, CVC crawlspace, conditioned space, unconditioned space (piping) or
none.
Duct or Piping R -Value from Directory of Certified Insulation Materials and/or manufacturer's data.
Heating/Cooling Load refer to CEC-approved load calculation procedure.
Heating/Cooling Equipment Capacity from the applicable CEC approved appliance directory. Note: location
elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's
literature).
Cooling Equipment Type must be one of the following:
SplitAirCond:
Split system air conditioner
PckgAirCond:
Packaged air conditioner
SplitHeatPump:
Split system heat pump
PckgHeatPump:
Packaged heat pump
RoomHeatPump:
Room heat pump
LrgPkgHeatPump:
Large packaged heat pump (z 65,000 Btu/hr output). Substitute
EER for SEER when SEER is not available
RoomAirCond:
Room air conditioner. Minimum SEER varies`
LrgPkgAirCond:
Large packaged air conditioner (z 65,000 Btu/hr output).
Substitute EER for SEER when SEER is not available
EvapDirect:
Direct evaporative cooling system. For compliance calculation
purposes, fixed values: SEER = 1 1 .0; duct location = attic; duct
insulation R -value = 4.2
Evapindirect:
Indirect evaporative cooling system. For compliance calculation
purposes, fixed values: SEER = 13.0; duct location = attic; duct
insulation R -value = 4.2
*Refer to California Energy Commission ) publication Appliance EfAciency Regulations, P400-92-029
WATER HEATING SYSTEMS
See Page 4 of 4
INSTALLATION CERTIFICATE (page 4 of 4) CF -6R
The following is an explanation of many ot the input va ues -required on thisform:
WATER HEATING SYSTEMS
Distribution Systems Refer to Residential Manual for more details
Standard:
Standard
Pipe Insulation:
Pipe Insulation on all 3/4 -inch pipes
POU/HWR:
Point of Use/Hot Water Recovery System
Recirc/NoControl:
Recirculation loop with no controls
Recirc/Timer:
Recirculation loop with a timer
Recirc/Temp:
Recirculation loop with temperature control
Recirc/Time+Temp:
Recirculation loop with a timer and temperature control
Recirc/Demand:
Recirculation loop with demand control
Water Heater Type
Storage Gas, Oil or Electric
Heat Pump
Instantaneous Gas
Instantaneous Electric
Large Storage Gas
Indirect Gas (Boiler)
FENESTRATION/GLAZING
Fenestration:
Information Needed
Operator Type:
Energy Factor
Recovery Efficiency Standby Loss
Rated Input
Yes
No No
No
Yes
No No
No
No
Yes No
No
Yes
No No
No
No
Yes Yes
Yes
No
Yes (AFUE) No
Yes
FENESTRATION/GLAZING
Fenestration:
Windows, sliding glass doors, french doors, skylights, garden
windows, and any door with more than one square foot of glass
Operator Type:
Slider, hinged, fixed
U -Value:
Installed U -value must be less than or equal to value from CF -1 R
OR
Installed -weighted average U -value for the total fenestration area
is less than or equal to value from CF -1 R
INSULATION CERTIFICATE IC -1
Number and Street City
County Subdivision o —tN um b a
Description of Installation
1. ROOF
Material
Thickness (inches)
N
CEILING
Brand Name
Thermal Resistance (R -Value)
Batt or Blanket Type Brand Name
Thickness (inches) Thermal Resistance (R -Value)
Loose Fill Type Brand Name
Contractor/s min Installed welght/ft? Ib Minimum, thickness inches
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value)
3. EXTERIOR WALL
Frame Type
A. Cavity Insulation
Material
Thickness (inches).
B . Exterior Foam Sheathing
Material
Thickness (inches)
4. RAISED FLOOR
Material
Thickness (inches)
5. SLAB FLOOR/PERIMETER
Material
Thickness (inches)
Perimeter Insulation Depth;(inches)
6. FOUNDATION WALL
Material
Thickness (inches)
Declaration
Brand Name
Thermal Resistance (R -Value)
Brand Name
Thermal Resistance (R -Value)
Brand Name
Thermal Resistance (-R-Value)
Brand Name
Thermal Resistance (R -Value)
Brand Name
Thermal Resistance (R -Value)
I hereby certify that the above .,Insulation k;Y as Installed In the building at the above location In conformance
with the current Eno(ay.Ett(clengy..StendsrdS.for.resldentlal buildings (Title 24, Part 6, California Code of
Regulatlons) as lndlcated on:thi"':.Cettlficate;of'Compliance, where applicable.
tem ignature; ate Installing Subcontractor(Co. Name -
FM -General Contractor (Co. Name) OR Owner
teT mks gnature; ate
tei m !fs "" gnaturo;
Revised July 1895
nstaIling Subcontractor(Co.Name)
General Contractor (Co. Name) OR Owner
Installing Subcontractor(Co. ama
General Contractor (Co, Name) OR Owner
MILGARD WINDOWS NFRC CERTIFIED U -VALUES
These 'U' Values are a simplification of various glass thicknesses and grid combinations.
A specific glazing option may have a value of .02 to .03 lower than shown.
"California Energy Commision Default Table 'U' Value.
CLR OVER
CLR OVER
WINDOW
CALIFORNIA
CLR OVER
HARD -COAT
CLR/CLR
HARD -COAT
TYPE
DEFAULT
CLR/CLR
HARD -COAT
LOW -E
HEAT
L WHEAT
MIRROR 6 T
VALUE
CLR/CLR
ARGON
LOW -E
ARGON
MIRROR 88
HORIZONTAL
CLEAR .55
SLIDER
LOW -E.50
.50
.48
.40
.37
.31
.26
SINGLE
CLEAR .55
HUNG
LOW -E.50
.50
.48
.40
.37
.31
.26
PICTURE
CLEAR .52
49
WINDOW
LOW -E.47
.46
.38
.35
.29
.23
J
Z
Z
AWNING
CLEAR.55
.42
36
.33
.27
.23
LOW -E.50
.43
CASEMENT
CLEAR .55
LOW -E.50
.43
.42
.36
.33
.27
.23
SLIDING
CLEAR .50
49
GLASS DOOR
LOW -E.45
.48
.40
.36
.30
.24
WIDE STILE &
CLEAR.50
49
RAIL DOOR
LOW -E.45
.48
.41
.38
.33
.29
HORIZONTAL
CLEAR.87
75
N
SLIDER
LOW -E.82
.73
.64
.61
a
SINGLE
CLEAR.87
72
HUNG
LOW -E.82
.74
.63
.60
t
PICTURE
CLEAR .72
61
3
WINDOW
LOW -E.67
.59
.49
.46
..
CASEMENT/
CLEAR.87
73
AWNING
LOW -E.82
.71
.64
.61
Z
PATIO DOOR
CLEAR .77
j
(410)
LOW -E.72
.77
.76
.68
.64
J
Q
PATIO DOOR
CLEAR .72
*.72
*.72
(415)
LOW -E.67
.66
.63
HORIZONTAL
CLEAR .92
SLIDER
LOW -E.87
.75
.73
.65
.63
U)
SINGLE
CLEAR .92
74
HUNG
LOW -E.87
.72
.64
.61
PICTURE
CLEAR .77
61
3
WINDOW
LOW -E.72
.59
.50
.46
CASEMENT/
CLEAR .92
73
Z
AWNING
LOW -E.87
.72
.65
.62
PATIO DOOR
CLEAR .82
• 82
78
Q
(410)
LOW -E.77
.70
.66
PATIO DOOR
CLEAR .721
, 72
• 72
(415)
LOW -E.67
.66
.63
These 'U' Values are a simplification of various glass thicknesses and grid combinations.
A specific glazing option may have a value of .02 to .03 lower than shown.
"California Energy Commision Default Table 'U' Value.
COMPUTER METHOD SUMMARY Page 1 C
Project Title.......... Meier Residence :pate........ 02/17/9
Pro eat Address........ *******
La Qu n a a *v4.50*
Documentation Author... Carole -.Christensen *******
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
Climate Zone........... 15
Building Perm1t
Plan theck I Date
Field ec a e
Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
I MICROPAS4 v4.50 File-MEIER08W Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User- Run-DrpFau78AC10.OR13.38.4
MICROPAS4 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
2.84
3.39
-0.55
Space Cooling..........
32.69
32.88
-0.19
Water Heating..........
14.04
13.05
0.9
Total
4�,
49.32
0.25
Zone Type
HOUSE
Residence
*** Building complies with Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area..... 1524 sf
Building Type .............. Single Family Detached
Construction Type New
Building Front orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned volume.........
Footprint Area .............
Ground Floor Area..........
Slab -On -Grade Area...:.....
Glazing Percentage.........
Average Glazing U -value....
Average Ceiling Height.....
Slab On Grade
1
12344 of
1524 sf
1524 sf
1524 5f
15 % of floor area
0.82 Btu/hr-sf-F
8.1 ft
BUILDING ZONE INFORMATION
Floor # of Vent Special
Area Volume Dwell Cond- Thermostat Height Vent Area
(sf) (cf) Units itioned Type (ft) (sf)
1524 12344 1.00 Yes Setback 2.0 n/a
FROM : Construction Lead Sheets PHONE NO. : +909+763 6522 Feb. 19 1996 10:07AM P07-
COMPUTER
0=
COMPUTER METHOD SUMMARY Page 3 Cd:
Project Title.......... Meier Residence Date........ 02/17/
MICROPAS4 V4.50 File-MEYER08W Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 .User- Run-DrpFau78AC10.0R13.38.4
EXTERIOR SHADING
Area Thick
Mass Type (sf) (in)
HOUSE
1 SlabOnGrade 487 3.5
2 SlabOnGrade 1037 3.5
THERMAL MASS
Heat Conduct- Surface.
Cap ivity R -value Location/Comments
28.0 0.98 R-0.0 Ent.kitdin.morn.bath.hall
28.0 0.98 R-2.0 framing/cabinets/carpet
HVAC SYSTEMS
Minimum Duct
System Type Efficiency Location
HOUSE
Furnace 0.780 AFUE
ACSplit 10.00 SEER
Attic
Attic
WATER HEATING SYSTEMS
Duct Duct
R -value Efficiency
R-4 0.825
R-4 0.803
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Storage Gas Standard 1 0.57 40 R-12
SPECIAL FEATURES/REMARKS
Milgard fenestration U -values or better.
Area
Shading
SC of
Surface
(of)
Type
Ext Shade
HOUSE
4 Door
33.3
Bldg Shade
0.20
7 Door
40.0
Bldg Shade
0.20
10 Window
10.5
Bldg Shade
0.20
Area Thick
Mass Type (sf) (in)
HOUSE
1 SlabOnGrade 487 3.5
2 SlabOnGrade 1037 3.5
THERMAL MASS
Heat Conduct- Surface.
Cap ivity R -value Location/Comments
28.0 0.98 R-0.0 Ent.kitdin.morn.bath.hall
28.0 0.98 R-2.0 framing/cabinets/carpet
HVAC SYSTEMS
Minimum Duct
System Type Efficiency Location
HOUSE
Furnace 0.780 AFUE
ACSplit 10.00 SEER
Attic
Attic
WATER HEATING SYSTEMS
Duct Duct
R -value Efficiency
R-4 0.825
R-4 0.803
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Storage Gas Standard 1 0.57 40 R-12
SPECIAL FEATURES/REMARKS
Milgard fenestration U -values or better.
FROM : Construction Lead Sheets PHONE NO.
COMPUTER METHOD SUMMARY
ProjectTitle Meier Residence
••••••••.. encs
: +909+763 0522 Feb. 19 1996 10:07AM P02
Page 2 C-:
.. .��
Date.... .. 02/17/c:
MICROPAS4 v4.50
File-MEZER08W Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User- Run-DrpFau78AC10.0R13.38.4
OPAQUE
SURFACES
Area
U-
Insul Act
Solar
Form 3 Location/
Surface
(sf)
value
R-val Azm Tilt
Gains
Reference Comments
HOUSE
1
Wall
80
0.088
13 270
90 No
W.13.2X4.16 front
2
Wall
80
0.088
13 270
90 Yes
W.13.2X4:16 front
3
Wall
240
0.088:13.
180..
90 Yes
W.13.2X4.16 right
4
Wall
19
0.088
13 180
90 No
W.13.2X4.16 right
5
Wall
181
0.088
13 90
90 Yes
W.13.2X4.16 back
6
Wall
24
0.088
13 90
90 No
W.13.2X4.16 back
7
Wall
150
0.088
13 0
90 No
W.13.2X4.16 left
8
Wall
283
0.088
13 0
90 Yes
W.13.2X4.16 left
9
Wall
288
0.086
13 270
90 No
W.13GAR ' to garage
10
Roof
1524
0.034
38 n/a
0 Yes
R.38.2X4.24F attic
11
Door
20
0.330
0 270
90 No
None solid wood
PERIMETER LOSSES
Length
F2 Insul Solar
Surface
(ft) Factor R-val Gains
Location/Comments
HOUSE
T
12
SlabEdge 163
0.720 R-0
No
to outside
13
SlabEdge
3
0.550 R-0
No
to garage
14
SlabEdge
33
0.500 R-0
No
to garage
FENESTRATION SURFACES
# of
Vent
SC SC Interior
Area Pan-
Frame
Open
U- Act
Glass Int Shading/
Surface
(sf) es
Type
Type
value Azm
Tlt. Only Shade Description
HOUSE
r
1
Window
24.0 2
Metal
Slider
0.870 270
90 0.88 0.58 Blinds.Lt
2
Window
14.0 2
Metal
Slider
0.870 180
90 0.88 0.58 Blinds.Lt
3
Window
14.0 2
Metal
Slider
0.870 180
90 0.88 0.58 Blinds.Lt
4
Door
33.3 2
Metal
Slider
0.770 180
90 0.88.0.58 Blinds.Lt
5
Door
33.3 2
Metal
Slider
0.770 90
90 0.88 0.58 Blinds,Lt
6
Window
2.0 2
Metal
Slider
0.870 90
90 0.88 0.58 Blinds.Lt
7
Door
40.0 2
Metal
Slider
0.770 90
90 0.88 0.58 Blinds.Lt
8
Window
20.0 2
Metal
Slider
0.870 0
90 0.88 0.58 Blinds.Lt
9
Window
20.0 2
Metal
Slider
0.870 0
90 0.88 0.58 Blinds.Lt
10
Window
10.5 2
Metal
Slider
0.870 0
90 0.88 0.58 Blinds.Lt
11
Window
17.0 2
Metal
Slider
0.870 0
90 0.88 0.58 Blinda.Lt