Loading...
14987 (SFD)Builin Address 52-925 Eisenhower Dr. Owner William J. Cox P.O. BOX 1504 78-495 CALLE TAMPICO LA OUINTA, CALIFORNIA 92253 Mailin Address CityZip Tel. Contractor I Address I- City p State Lic. I City & Classif. Lic. # Arch., Engr., -Designer Address Tel. City Zip State Lic. # { LICENSED CONTRACTOR'S DECLARATION I herefb .affirm that I am licen�ed under provisions of Chapte 9 commencing with Section 7000) of ill" 3' 111, the-Bus'nes and Professions Code, and icense is in full force and . y�effect 1,t� �M� �p�� SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: -Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cade, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects 'the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will . do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's. License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees, .provided that such improvements are not intended or offered for sale. If, however, the building. . or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or knprove for the purpose of sale.) ' ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) pcensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy, No. Company Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers"Compensation Laws of California Date Owner NOTICE TO APPLICANT: If, alter making this Certificate o! Exemption you 'should 'become subject to the Workers' Compensation provisions of the of. Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER -TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is a building permit when properly filled out, signed -and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that•the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, .Zip s N0. 14987 BUILDING: TYPE CONST. VN OCC. GRP. A.P. Number 771-326--021 Legal Description Lot 10 Block 161 Project Description SD Si e t .1224. Stc New ❑ Add ❑ No. Dw. Units Alter ❑ Repair ❑ -Demolition ❑ Permit does not include block gall or pool.. Distances: ` Front Setback from Cen Rear Setback from Rear Side Street Setback frit Side Setback fromtopl FINAL DATE Estimated, Valuation $75010.00 Date PERMIT AMOUNT .Plan Chk. Dep. '50.00 >� Plan Chk. Bal. Validation: 193.50 Const.. 531.50 Mech. 55.50 Electrical 114.96 Plumbing 132.00 S.M.I. 7.53 Grading 20.00 Driveway Enc. 00 Infrastructure 1,685.49_ Precise Plan 25.00 TOTAL 3,015.48 2,765.+48 REMARKS. A'. ZONE: BY: Minimum Setback Distances: ` Front Setback from Cen Rear Setback from Rear Side Street Setback frit Side Setback fromtopl FINAL DATE INSF Date Issued by: • e r Validated by: >� Validation: 0 I CONSTRUCTION ESTIMATE I NO. I ELECTRICAL FEES I NO. I Pl. 1ST FL. SO. FT. ® $ UNITS' UNDERGROUND A.C. UNIT YARD SPKLR SYSTEM 2ND FL. SO. FT. ROUGH PLUMB. BONDING HEATING (ROUGH) MOBILEHOME SVC. BAR SINK POR. SO. FT. ® OR S 7 ROUGH WIRING GAR. SO. FT. ® POWER OUTLET ROOF DRAINS FOUND. REINF. a /� �i GAS (ROUGH) DRAINAGE PIPING CAR P. I SO. FT. OTHER APPJEOUIP. WALL SO. FT. GAS (FINAL) - DRINKING FOUNTAIN SO. FT. ® URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER HEATER WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SYSTEM WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FRAMING GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED o/ LAUNDRY TRAY AIR HANDLING UNIT CFM REMARKS: KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® 3/ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLU 9� UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS � 9� / OR S 7 ROUGH WIRING DUCT WORK ROCKSTORAGE FOUND. REINF. a /� �i GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) - TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING CU. yd. $ -Plus-x$ c$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFINGv o/ REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING / MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION 9� CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL aPRr 17 95 B^o 3�API CHCAGO TITLE RECORDING REQUESTED CHICAGO TITLE COMPANY AND WHEN RECORDED WIA IL TO WILLIAM J. COX —1 P.O. BOX 967 PALM DESERT, CA. 92261 P.1/2 L Escrow No. 35241 -23 Order N9_ 581577 - 4 ' —�� SPACE AeovI; TH13 UN9 FOR RECXMERS USE GRANT DEED THE UNDERSIGNED GRANrOR(S) DECLARE(S) DOCUMENT'AR'Y TRANSFER TAX IS $16.50 ❑ uninoorporated arra ❑ City of computed on the full value of the interest or property conveyed, or Is ❑ computed on the full value less the value of liens or encumbrances remaining at time of salt, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, PAULA LEE NOFZIGER, AS TRUSTEE OF TRUST A OF THE NOFZIGER TRUST DATED PAULA LEE NOFZIGER, AS TRUSTEE OF TRUST 8 OF THE NOFZIGER TRUST DATED hereby GRANT(S) to WILLIAM T. COX, A MARRIED MAN, AS HIS SEPARATE PROPERTY r0s Percet No. 26-021 12/10/86, AND 12/10/86 the following described real property in the County of , RIVERSIDE , State of California: LOT 10 BLOCK 161 OF SANTA CARMELITA UNIT 16, AS PER MAP THEREOF RECORDED IN THE OFFICE OF THE RECORDER OF RIVERSIDE COUNTY AT PAGE 99 OF BOOK OF MAPS APN: 773-326-021. Dated March 14, 1995 STATE OF CAUFORNIA COUNTY OF On ) 7j74j a Afotaiy Publ)c in 0d for said SS. bofore me, and State, personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the personO whose nameX Is/o subscribed 10 the within Instrument and acknoWledgad to me thht T4/ohe/executed the same In *her/t r authorized capacity( ), and that by *har/t lllr , signature on Inetrument the person or the entity upon behalf of which the person acted, executed the Inatrument. 1MTNESS hand and official seal. Signature of Notary MAIL A STATEMENTS TO PARTY SHOV44 ON FOLLOWWG LINE: C bh PAULA LEE NO ZI ER RUS E OF TRUST A OF THE NO RUST DAT1D A2,,110/86 /, /1 i fiv ua• a+Y •+ TRUST 13 Ori' THE N R" TRUST DATED 12/10/86 KAREN 771L • • COMM ... 1022160 U NOTARY PUSUGCALIFORNIA !n '' ORANGE COUNTY My Term Exp. April 3, 1998 FOR NOTAW SEAL OR STAMP IF NO PARTY SO SHOWN, MAIL AS DIRECTED ABOVE Name Street Address City, State & Zap DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date5/4/95 1 Type of Permit I La Quinta No. 13435 Permit # Owner Name William J. Cox Log N o. 52-925 Street Eisenhower Dr. City La Quinta Zip 92253 Study Area 111 APN # I I Tract # Lot # 0 Square Footage 11224 Type of Development Single Family Residence I No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.72 x 1224 or $ 2,105.28 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By William J. Cox & Sons Telephono':; Name on the check By Dolores A. Ballesteros Superintendent Fee collected /exempted by Mary Lou Lopez Payment Recei'ued Signature 6li6ck No. 5002 Collector: Attach I�Aof county or city plan the plication form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting 30 Day Te:aporary Q�zit t �I&��At� ,0 1 nu 30 nay Teraporary - - &�OF TiN of Ea utnta This Certificate issued pursuant to.the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance • this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: Building Official . POST IN A OONe?ICUOUS PLACE BUILDING ADDRESS 52-925 Eisenhower Dr. Use Classification Sinale Fa 1i1v Dwelli.ncTBldg. Permit No. 14 27 Group • I:3 Type ConstructionUK Fre Zone Use Zone —ep. Owner of Building Williar; J. Cox Address 66-900 Dillon Road City Desert Hot Springs, Cr -k.,-0,2240 By; Daniel P. Crawford Jr. rilo�fi - Dote; August 1, 1995/Expires 9/1/95 Building Official . POST IN A OONe?ICUOUS PLACE •.L INSTALLATION CERTIFICATE CF -6R Use of this form to satisfy the requirements of the Administrative Code Is optional, but the Information must bo provided and posted. Site Address Permit Number An installation certificate is required to be posted at the building site prior to the issuance of the occupancy permit; this form may be used to meet these requirements. All appliance categories listed below are the actual equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better than the appliance specified on the car ificate of compliance (Form CF -1 R). This certificate (or its equivalent) shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. Refer to the reverse side of this certificate for an explanation of information required. I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS: Heating Equipment Heating Equip. CEC Certified Actual Distribution Duct or Heating Load Heating Type (Packaged Manuf. Make & Efficiency Type and Piping Before Over- Equipment heat Rum . etc) Model Number IAFUE. etc.1 LQcatQLt R -Value Sizing(Btuh) Caoacity (Btuh) Cooling Equipment Cooling Equipment Type (Packaged CEC Certified Compressor Unit heat Rum. _tcl _ Manuf. Make &Model Number Signature, Date WATER HEATING SYSTEMS Actual Efficiency Duct Duct r i HVAC Subcontractor (Co. Name) I OR General Contractor OR Owner Distrib. Water CEC Certified Energy Tank Insul Internal Pilot Rated Solar/ ' System Heater Manuf. Make & Factor/ Volume Wrap Insul. Standby Light Input Wood Iya$ e/ Model V _ Effig,_ (gallons) R-yalue R-yalue Loss (%) 1@LuW kW/Btu Credits, I f i i FAUCETS & SHOWER HEADS: ;w All faucets and showerheads installed are listed in the Commissions Directory Of Certified Faucets And Showerheadsq pursuant to Title -24, Part 6, Subchapter 2, Section 111. Signature, Date Revised December 1992 f Plumbing Subcontractor (Co. Name) OR General Contractor OR Owner 4 INSTALLATION CERTIFICATE _ _ _ CF' -6R The following is an explanation of many of the input values required on the opposite side of this form: HVAC SYSTEMS Heating Equipment Type; must be one of the following: Furnace: Gas or oil -fired central furnaces space heaters. Boiler: Gas or oil -fired boilers. Pck HeatPum : Packa ed central heat pumps. S litHeatPum : S lit t;entral heat pumps. RoomHeatPum : Room heat eump. Lr Pck HeatPum : Lame Packaged Heat Pumps (>_65,000 Btuh output). Electric: Electric resistance heating HSPF=3.413. Radiant electric resist. heatin2_2HSPF_3r55 CombinedH dro: Reference vrater heater under water heatinc_sYotems, below. Refer to CEC publication "Appliance Efficiency Regulations% P400-92-029. CEC Certified Manuf. Make & Model Number; from applicable CEC appliance directory. Actual efficiency; from applicable CEC appliance directory. Distrib type & location; Distrib type is "Ducts", "Piping" or both. Duct location is "Attic", "Crawlspace", "CVCerawispace" or "Conditioned space" Piping location is to be listed as "Coad. " or "Uncond. ". Duct or Piping R -Value; from the Directory Of Certified Insulation Materials andlor manuf's data. Heating Load Before Oversizing; refer to CEC -approved heading load calculation procedure. This is the heating load result prior to application of the factor recommended in the load calculation procedure for oversizes the appliance to account for the use of a setback thermostat. Heating Equipment Capacity; from the applicable CEC appliance directory. Note; location elevations over 2000 ft above sea level require a derating of output capacity (refer to manufacturers literature). Coolin_q Equipment Type; must be one of the followinq: S litAirCond: Split sstem air conditioner. Pck AirCond: Packaged air conditioner. S /itHeatPum Split system heat pump. Pck HeatPum : Packaged heat pump. RoomHeatPum : Room heat pump. _Y- LgPckgHeatPump: Large Packaged Heat Pumps (,65,000 Stuh output). Substitute EER for SEER when SEER is not available. RoomAirCond. Room air conditioner. Min. SEER varies' LrgPckgAirCond: Large Packaged Heat Pumps (>t 5,000 Biuh output). Substitute EER for SEER when Fde irrlTemp: SEER is not available. EvapDirect: Direct Evaporative Cooling System. The SEER is fixed at SEER=11.0. The duct condition is to be fixed at location=attic and duct insulation R-value=4.2. Evapindirect: Indirect Evaporative Cooling System. The SEER is fixed at SEt=R_13.0. The duct condition is to be fixed at location=attic and duct insulation R-value=4.2. Refer to CEC publication "Appliance Efficiency Regulations", P400-92-029. WATER HEATING SYSTEMS Distribution system type: refer to Residential IvSanual for more detp'ls. Standard: Standard POU/HWR: Point of use/Hot water recovtj Pie Insulation: Pipe Insulation _ Recirc/NoControl: _ Recirculation loowith no control Recirc/Timer: Recirculation loop with a timer �Recirc/Demand: Recirculation loop with demand _ Yes r control Recirc/Time+Temp: __ Recirc. loop with timer and toop— Fde irrlTemp: _ Recirculation leap with temperature Yes control control The table below summarizes the water heating system items needed by water heater type. Input item NAECA Storage Gas or Oil NAECA Storage Electric NAECA Heat Pum Instant. Gas t instant. i Electric i Large Storage Gas Indirect Gas Boiler Energy Factor Yes Yes Yes _ Yes r Pilot Input, Btu Yes j Yes Recov. Eff., fraction Yes Yes I (AFUE) Standby Loss, % Tank Volume al. Yes Yes Yes _Yes Yes Yes Tank Insulation, R Yes Yes Ext. Insulation, R Yes Yes Yes _ Yes , Yes Additional Information Re uired If Combined Hy dronic System: Rated Input, kBtuh . Yes Yes Yes Rated Input, kWl Yes Yes _ Rec. Eff, fraction Yes . 40 TITLE -24 ENERGY CALCULATIONS Carole Christensen, Energy Analyst ENERGY CALCULATIONS FOR: CTZ 15 Dual glazing, Std Drapes Walls R-13, Roof R-38 attic; Duct R-5.2; AFUE 78; A/C SEER 10.0; 40 gal gas water heater CONTENTS CF -11R MF -1R C -2R C -3R HVAC Sizing Philips fenestration specifications CF -6R to be posted and completed on site when equipment is installed 47-596Lake Canyon Drive, Aguanga, CA 92536 79-733 Country Club Drive, Bermuda Dunes, CA 92201 1-800-735-8152 Member CABEC California Association ofBuilding Energy Consultants Wm. J. Cox & Sons 66-900 Dillon Road Desert Hot Springs, CA PROJECT: Cox Plan 1218.5 Address: Standard Proposed Compliance North 52.56 51.45 + 1.11 East 52.56 52.25 +0.31 South 52.56 51.15 +1.41 West 52.56 52.11 +0.45 CTZ 15 Dual glazing, Std Drapes Walls R-13, Roof R-38 attic; Duct R-5.2; AFUE 78; A/C SEER 10.0; 40 gal gas water heater CONTENTS CF -11R MF -1R C -2R C -3R HVAC Sizing Philips fenestration specifications CF -6R to be posted and completed on site when equipment is installed 47-596Lake Canyon Drive, Aguanga, CA 92536 79-733 Country Club Drive, Bermuda Dunes, CA 92201 1-800-735-8152 Member CABEC California Association ofBuilding Energy Consultants n TABLE OF CONTENTS TOC Project Title.......... COX Plan 1218.5 Date....:... 03/16/95 Project Address........ Documentation Author... Carole Christensen Bu> ing Permi Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Plan Check Da - -e Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check Date C'1 i Ynn+c 7nnc 1 r, MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -TOC User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 TABLE OF CONTENTS Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 4 FORM C -2R ................. 6 FORM C -3R ................. 10 HVAC SIZING............... 12 C L+ L I . i CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 Project Address........ Documentation Author... Carole Christensen Company................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Perm -11-7 Plan Check Date Field Check/ Date MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... 1218.5 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall R-13 0.083 Roof R-38 0.035 Attic Door R-0 0.330 Solid Wood SlabEdge R-0 0.900 To Outside SlabEdge R-0 0.720 To Outside SlabEdge R-0 0.550 To Garage SlabEdge R-0 0.500 To Garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 12.0 0.820 2 Drapes.Std None Yes Metal Door Front (N) 20.0 0.550 2 Drapes.Std Bldg Shade None Glz<50% Window Left (E) 4.0 0.820 2 Drapes.Std None None Metal Window Left (E) 20.0 0.820 2 Drapes.Std None None Metal Window Back (S) 16.0 0.820 2 Drapes.Std None Yes Metal Window Back (S) 16.0 0.820 2 Drapes.Std None Yes Metal Door Back (S) 33.3 0.770 2 Drapes.Std None Yes Metal Window Right (W) 15.0 0.820 2 Drapes.Std None None Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade S1abOnGrade Equipment Type Furnace ACSplit Tank Type Storage Yes 260 3.5 ent.kit.dining.svc No 959 3.5 Covered HVAC SYSTEMS Minimum Duct Duct Thermostat Efficiency Location R -value Type 0.780 AFUE Attic R-5.2 Setback 10.00 SEER Attic R-5.2 Setback WATER HEATING SYSTEMS Number Tank - External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value Gas Standard 1 0.544 EF 40 R-12 SPECIAL FEATURES/REMARKS This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. Philips fenestration U -values or better. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Wm. John Cox, II Company. Wm Cox & Sons Address. 66900 Dillon Road Desert Hot springs, CA 90 Phone... (619) 251-2780 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... #, Signed.. (date) DOCUMENTATION AUTHOR Name.... Carole Christensen Company. Carole Christensen, EA Address. 47-596 Lake Canyon Dr. Aguanga, CA 92536 Phone... 1-800-735-8152 Signed.. Rate) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 Project Address........ Documentation Author... Carole Christensen Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permi Plan Check Date Field Check/ Da e MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM MF -1R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM MF -1R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. 0 COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 Project Address........ Documentation Author... Carole Christensen Company.... .......... Carole Christensen, EA Telephone............ 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permi Plan Check Da e Field Check/ Date MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 MICROPAS4 ENERGY USE SUMMARY 2.64 Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.64 2.12 0.52 Space Cooling.......... 33.58 33.29 0.29 Water Heating.......... 16.34 16.04 0.30 North Total 52.56 51.45 1.11 Space Heating.......... 2.64 2.64 0.00 Space Cooling.......... 33.58 33.57 0.01 Water Heating.......... 16.34 16.04 0.30 East Total 52.56 52.25 0.31 Space Heating.......... 2.64 3.20 -0.56 Space Cooling.......... 33.58 31.91 1.67 Water Heating.......... 16.34 16.04 0.30 South Total 52.56 51.15 1.41 Space Heating.......... 2.64 2.59 0.05 Space Cooling.......... 33.58 33.48 0.10 Water Heating.......... 16.34 16.04 0.30 West Total 52.56 52.11 0.45 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type.......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... 1218.5 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear COMPUTER METHOD SUMMARY Page 7 C -2R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... Slab On Grade (Package D) 1 10662 cf 1218.5 sf 1218.5 sf 1218.5 sf 11.2 % of FA 8.8 ft BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Thermostat Zone Type (sf) (cf) Units itioned . Type HOUSE Residence Surface HOUSE 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Wall 7 Wall 8 Roof • 9 Door Surface HOUSE 1219 10662 1.00 Yes Setback OPAQUE SURFACES Area U- Insul Act Solar (sf) value R-val Azm Tilt Gains Form 3 Reference Vent Special Height Vent Area (ft) (sf) 2.0 n/a Location/ Comments 20 0.083 R-13 0 90 No W.13.2X4.16 84 0.083 R-13 0 90 Yes W.13.2X4.16 240 0.083 R-13 90 90 Yes W.13.2X4.16 239 0.083 R-13 180 90 Yes W.13.2X4.16 48 0.083 R-13 270 90 No W.13.2X4.16 299 0.083 R-13 270 90 Yes W.13.2X4.16 200 0.083 R-13 0 90 No W.13.2X4.16 1219 0.035 R-38 0 0 Yes R.38.2X4.24A Attic 20 0.330 R-0 0 90 No None Solid Wood PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 10 SlabEdge 7 0.900 R-0 No To Outside 11 SlabEdge 120 0.720 R-0 No To Outside 12 SlabEdge 14 0.550 R-0 No To Garage 13 SlabEdge 14 0.500 R-0 No To Garage COMPUTER METHOD SUMMARY Page 8 - C -2R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4.v4.02 File-JCOX0295 Wth-CTZ15S92. Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 12.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 2 Door 20.0 2 Glz<50% Hinged 0.550 0 90 0.88 0.78 Drapes.Std 3 Window 4.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std 4 Window 20.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std 5 Window 16.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 6 Window 16.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 7 Door 33.3 2 Metal Slider 0.770 180 90 0.88 0.78 Drapes.Std 8 Window 15.0 2 Metal Slider 0.820 270 90 0.88 0.78 Drapes.Std OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 12.0 3.0 4.0 2.0 0.5 0 0 0 0 0 0 0 0 5 Window 16.0 4.0 4.0 2.0 0.5 0 0 0 0 0 0 0 0 6 Window 16.0 4.0 4.0 2.0 0.5 0 0 0 0 0 0 0 0 7 Door 33.3 6.8 5.0 2.0 0.5 0 0 0 0 0 0 0 0 EXTERIOR SHADING Area Shading SC of Surface (sf) Type Ext Shade HOUSE 2 Door 20.0 Bldg Shade 0.20 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 S1abOnGrade 260 3.5 28.0 0.98 R-0.0 ent.kit.dining.svc 2 SlabOnGrade 959 3.5 28.0 0.98 R-2.0 Covered COMPUTER METHOD SUMMARY Page 9 C -2R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location, R -value Efficiency HOUSE Furnace 0.780 AFUE Attic R-5.2 0.835 ACSplit 10.00 SEER Attic R-5.2 0.820 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.544 40 R-12 SPECIAL FEATURES/REMARKS This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. Philips fenestration U -values or better. CONSTRUCTION ASSEMBLY Page 10 3R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 Reference Name . W.13.2X4.16 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ....... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1. SIDE.WDO.5X8 Wood, bevel, 0.5 by 8 in. lapped 0.81 0.81 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 r I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 15.17 5.63 •FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 15.17 x 0.85) +-(1 / 5.63 x 0.15) = 0.083 Btuh/sf-F Total R -Value: 1 / 0.083 = 12.10 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 11 3R Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 Reference Name . R.38.2X4.24A Description .:.. Roof R-38 2x4 24oc Type .......... Roof R -Value ........ 38 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value O. FILM. EX 1. SHNGL.CEMENT 2. BLDG.PAPER 3. PLY.0.50 4c. AIR.RF.3.50 4f. FIR.2X4 5c. BATT.R38.0 6. GYP.0.50 I. FILM.IN.RF Exterior air film: winter value Asphault-cement shingles Building paper (felt) 0.50 in plywood 3.5 in & greater air space: heat flow up 2x4 in fir framing R-38 batt insul (cavity > 11.25 in) 0.50 in gypsum or plaster board Inside air film: heat flow straight up FRAMING ADJUSTMENT CALCULATION Cavity Total Unadjusted R -Values Framing 0.17 0.17 0.21 0.21 0.06 0.06 0.62 0.62 0.80 -- -- 3.46 38.00 -- 0.45 0.45 0.61 0.61 40.92 5.58 Total U -Value: (1 / 40.92 x 0.93) + (1 / 5.58 x 0.07) = 0.035 Btuh/sf-F Total R -Value: 1 / 0.035 = 28.36 sf-F/Btuh HVAC SIZING Project Title.......... COX Plan 1218.5 Project Address........ Documentation Author... Carole Christensen Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Page 12 HVAC Date........ 03/16/95 Building Permit Plan Check Da e Field Check/ Date MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location.......:.... Latitude... .... ........ Winter Outside Design ...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.... .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1218.5 sf 10662 cf Front Facing PALM SPRINGS 33.8 degrees 31 F 70 F 113 F 78 F 35 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY 0 deg (N) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9752 5430 Glazing Conduction ............... 4084 3665 Glazing Solar .................... n/a 4049 Infiltration ..................... 5846 3896 Internal Gain .................... n/a 2550 Ducts ............................ 1968 1959 Sensible Load .................... 21650 21550 Latent Load ...................... n/a 4310 Minimum Total Load 21650 25860 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 13 HVAC Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 GENERAL INFORMATION Floor Area ................. Volume.. . ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside'Design ....... Summer Outside Design...... Summer Inside Design........ SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 1218.5 sf 10662 cf Front Facing 90 deg PALM SPRINGS 33.8 degrees 31 F 70 F 113 F 78 F 35 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 9752 5430 Glazing Conduction ............... 4084 3665 Glazing Solar .................... n/a 5708 Infiltration ..................... 5846 3896 Internal Gain .................... n/a 2550 Ducts ............................ 1968 2125 Sensible Load .................... 21650 23375 Latent Load ...................... n/a 4675 Minimum Total Load 21650 28050 (E) ni Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 14 HVAC Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 GENERAL INFORMATION FloorArea ................. Volume.. ... ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.. ..... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1218.5 sf 10662 cf. Front Facing PALM SPRINGS 33.8 degrees 31 F 70 F 113 F 78 F 35 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating (Btuh) Opaque Conduction and Solar...... 9752 Glazing Conduction ............... 4084 GlazingSolar .................... n/a Infiltration......... 5846 Internal Gain .................... n/a Ducts ............................ 1968 Sensible Load .................... 21650 LatentLoad ...................... n/a 180 deg (S) Cooling (Btuh) 5430 3665 3499 3896 2550 1904 20945 4189 Minimum Total Load 21650 25134 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 15 HVAC Project Title.......... COX Plan 1218.5 Date........ 03/16/95 MICROPAS4 v4.02 File-JCOX0295 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-Drp 78.10.OR13.38.5.2 GENERAL INFORMATION Floor Area ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange..... ... ..... Interior Shading Used ...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1218.5 sf 10662 cf Front Facing PALM SPRINGS 33.8 degrees 31 F 70 F 113 F . 78 F 35 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... Minimum Total Load 270 deg (W) Heating Cooling (Btuh) (Btuh) 9752 5430 4084 3665 n/a 5591 5846 3896 n/a 2550 1968 2113 21650 23246 n/a 4649 21650 27895 Note: The loads shown are only one.of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. is L PHILIPS PRODUCTS 7/15/93 THERMAL TRANSMITTANCE VALUES ACCORDING TO NFRC 100-91 NOTES: (1) LOW E IS LOF ENERGY ADVANTAGE (2) FOR RESIDENTIAL PRODUCTS COMPARISON, THE USE OF -AA- SIZE U -VALUE IS RECOMMENDED. (3) ARGON GAS OPTION NOT AVAILABLE IN CALIFORNIA AT THIS TIME. U -VALUE:.:. OVERALL.10?::'... NFRC 100-91` SERIES THICKNESS:::: ;ALUMINUM.; :; .:.CL :EARA.. .: ° .LOW: E 8` STYLE (INCH).:::: FRAME' ' CLEAR: :: ARGON<' `:LOW E >' ARGON;:' AA::* 88` K 1/2 X X 0.82 0.76 HORIZONTAL 1/2 X X 0.78 0.72 SLIDER 1/2 X X 0.72 0.66 1/2 X X 0.67 0.61 KN 1/2 X X 0.84 0.78 HORIZONTAL 1/2 X X 0.80 0.74 SLIDER 1/2 X X 0.75 0.68 1/2 X- X 0.70 0.63 K 1/2 X X 0.85 0.79 SINGLE 1/2 X X 0.81 0.75 HUNG 1/2 X X 0.75 0.69 1/2 X X 0.70 0.64 KN 1/2 X X 0.87 0.81 SINGLE 1/2 X X 0.83 0.77 HUNG 1/2 X X 0.78 0.71 112 X X 0.73 0.66 5/8 X X 0.61 0.59 5/8 X X 0.57 0.56 5/8 X X 0.50 0.48 K 8 KN 5/8 X X 0.44 0.43 PICTURE WINDOW 1 X X 0.58 0.57 1 X X 0.56 0.54 1 X X 0.46 0.44 1 X X 0.42 0.40 K5 8 K6 5/8 X X 0.78 0.77 SLIDING 5/8 X X 0.75 0.73 GLASS 5/8 X X 0.67 0.65 DOOR 5/8 X X 0.63 0.61 NOTES: (1) LOW E IS LOF ENERGY ADVANTAGE (2) FOR RESIDENTIAL PRODUCTS COMPARISON, THE USE OF -AA- SIZE U -VALUE IS RECOMMENDED. (3) ARGON GAS OPTION NOT AVAILABLE IN CALIFORNIA AT THIS TIME.