Loading...
0204-040 (RER)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and.the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044; Business & Professionals Code). () I am exempt under Section - , B&P:C for this reason Date °s .f r_ Signature of Owneri 4Yy. ++ WORKER'S COMPENSATION DECLARATION C� I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor_Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation; insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ;K I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation pro..visions of Section 3700 of the Labor. Code„I shall forthwith comply with those provisions. 6 / Dater ' j Applicant; /)�t�?ii ! ✓ 'L Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $1:60,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and fog whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize, representatives of this City to enter upon the above-mentioned property for -inspection purposes., ""'Signature (Owner/Age” f ,t,',rt `, Dat � nt {� t� L�J BUILDING PERMIT PERMIT t/ 0204-040 DATE VALUATION SUM"M LOT TRACT JOB SITE ADDRESS ' i;�,d}3�% M APN r OWNER CONTRACTOR / DESIGNER / EN (NEER C+1RXkWR S.AXCHM O'tstiN;rTd1rSTIL DFR L.A.QLT'A CA 92253 () - CB14F USE OF PERMIT IMMODFL MUS17NO STRU TU1:.& t: ,-CONS R.UC:T NIE'W ROOF STRUC Ct RF, ABOVE ; !!iTWO. C0140'!RUCT IMO P,A.T10 CCV9 ;443 &0.). CfQV"V'itRT PR&EK1S73kdt'1CAR POI$T TO ONE C;FaIY (WA IAGZ. R& IMMODEL paus LS 'BE.i+aTI,CI`S�I .IBJ dr.J.l+ii Writ 'ERIMAINw C:Cia f �1*' Ct�1 4v" 4,i "d7CIfi1A r 101WO-50 PUAN CHECK, F -RE 101.000-439.3 J 8 COR.a"FRUCTION FEE 101-000-418.000 WCHANICAL FES 101-000-4,21-000 54�,Dg i:,t:.M:TRIC,AL FEZ 101.000-420.000 STRONG MOTION MR RIM -1). 1.01=( 00.2.41.000 = A#.Oa 3 ol PLIAI 2 0 Pioz i CITY OF LA QUINTA FINANCE DEPT SUB-7"OTAL MN€1ML1M.ON AND PL FSr CITEC'1,,,04 s2s, .:9d 'R OTAL )',1�,..6�1ltig'T;d!'1 RS DUE NOW 2a2M) RECEIPT DATE BY DA FIN ED INSPEC - U INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE TINSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs _ / Underground Ducts Forms &Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor _ Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath 17�- Drywall - Int. Lath Final Final 'U 2 BLOCKWALL APPROVALS steel POOLS - SPAS Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Bin # City of La Quinta Building 8T Safety Division P.O. Box 1504, 78-495 Calle Tampic La Quinta, CA 92253 - (760) 777-70k Building Permit Application and Tracking Sheet Permit # `� -�`I" Project Address: )� 6 u r Owner's Name: A. P. Number: Address: Legal Description: Contractor: -,t-OVA City, ST, Zip: Telephone: Address: Jr Project Description: City, ST, Zip: Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: S� 3.30 6>49 50 Address: City, ST, Zip: ..................................................... ....................................................... ...................................................... State Lic. # Name of Contact Person: Z Construction onT occupancy:TelePhone: Type: Project type Ie one): New Add'n Alter Repair Demo S # Stories: # Units: Telephone # of Contact Person:: Value of Project: 0 kA�- /-Estimated Do NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES 21 Plan Sets Plan Check submitted 1 Item Amount Structural Calcs. Reviewed, ready for corrections VIJ31131DZPlan Check Deposit Truss Calcs. Called Contact Person `15/ Ian Check Balance • Title 24 Calcs. Plans picked up Construction • Flood plain plan Plan ubmitted Mechanical vo; Grading plan 2"d Review, r v for correctionstissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.,%1.1. H.O.A. Approval Plans resubmitted $ �, Grading IN HOUSE:- '"' Review, ready for correction issue eveloper Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Q -r(j f�J�riit[/(/1S B f H L ✓i S I i (G Total Permit Fees IL A,a 9 cf� ,fib )ac -r 7>pA- l Y 1,50 IL A,a Ass &E P.O. Box 1504 nn% oF. 78-495 CALLE TAMPICO ,Vi,,jngBrighter Than Ever LA QUINTA, CALIFORNIA 92253 August 2, 2002 Ms. Christine Sanchez 53-980 Eisenhower Drive La Quinta, CA 92253 SUBJECT: REMODEL Dear Ms. Sanchez: (760) 777-7000 FAX (760) 777-7101 On March 25, 2002, your architect submitted a set of plans for approval of a remodel of an existing house that currently .does not comply with the development standards for the Cove Residential Zoning District. After review of the plans for the expansion of the legal nonconforming use, staff approved the addition provided the architectural treatment in front of the existing 'carport was pushed back to meet or match the existing house wall setback. The plans were stamped as such and you are now permitted to obtain the required building permits. Should you have any questions, please contact me. Sincerely, ERRY HERMAN ommunity Development Director JH:bjs c: Building and Safety Department R1 WING W//U_ Approved b at eso #. p Planning Commission- p city Council O'Com nity ev. ®ePL f� U Initials Case No. Exhibit - -D'With Conditions -� �� CITY"'OF �.A QUINTA BUILDING & SAFETY DEPT. APPROVED FO;;; CONSTRUCTION DATE�yBY 40e a---56`7- TITLE 24 REPORT f Title Title 24 Report for: Christine Sanchez 53-980 Eisenhower Drive La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: Date: 3/6/2002 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 i' TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist A Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 7 14 15 EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Christine Sanchez 3/6/2002 Project Title Date 53-980 Eisenhower Drive La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,312f? Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 1,312 ft2 Building Type: n/a (check one or more) Exposed Slab w/R-0.0 Perimeter Insulation Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family FXI Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type . Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-19 Wall (W.19.2x6.16) Wood 0.065 Exterior Wall R-11 Wall (W.1 1.2x4.16) Wood 0.098 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (South) 89.4 0.87 0.70 Bug Screen 0 ❑ ❑ 0 Front (South) 6.8 0.72 0.73 Bug ScreenX❑ ❑ ❑ x❑ Rear (North) 4.1 0.72 0.73 Bug Screen ❑ Q ❑ x❑ Rear (North) 25.5 1.28 0.80 Bug Screen X❑ ❑ ❑ FX Rear (North) 40.0 1.25 0.80 Bug Screen Q ❑ ❑ x❑ Right (East) 80.0 1.25 0.80 Bug Screen x❑ ❑ ❑ Q Right (East) 13.4 1.19 0.83 Bug Screen x❑ ❑ ❑ 0 ❑ ❑ ❑ ❑ El El El F1 El El El F1 ❑ ❑ ❑ ❑ El El El El Run Initiation Time: 03/06/02 22:31:56 Run Code: 1015482716 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 15 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Christine Sanchez Energy Fact*1 1 External 3/6/2002 Project Title Cap. or Recovery Standby Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Syst. Btu/hr Distribution Efficiency Loss (%) R -Value Heating Equipment Minimum Type and Duct or 0.53 n/a Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments f:entral Furnace 80% AFUE Ducts in Attic 2.1 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact*1 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Standard 1 40 900 50 0.53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or(� ner(per Busines rofessi s Code) Name: l V� J'i�QVl(Q Title/Firm: Address: I .'-,IP A A MV- 017 Documentation Author Name: Joan D. Hacker Title/Firm: Insu-Form Inc. Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-0216 UNI �' , . .Enforcement Agency Title/Firm: Address: Telephone: IEnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 15 1 Certificate of Compliance: Residential (Addendum) CF -1 R Christine Sanchez 3/6/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HIGH MASS Desiqn(see C -2R) - Verify Thermal Mass: 1312 sqft Exposed Slab Floor, 3.50" thick at Existing Living/Addition HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 03/06/02 22:31:56 Run Code: 1015482716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 15 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑ "§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. "§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ -§150(d): Minimum R-13 raised floor insulation in framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. ❑ §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. ❑ "§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181 A, or UL1818. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 15 Computer Method Summary (Part 1 of 3) C -2R C;hrigtone Sanchez Project Title R-Renhower nrivP La Qtfinta 3/6/2002 Date ,53-q80 Project Address Building Permit # Insu-Form Inc (760) 324-0216 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Field Check/Date Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Existing+Addition Budget Adjustment Space Heating 3.23 4.44 -1.21 Ratio F: 1272 / 1312 = 0.970 Space Cooling 38.39 76.38 -37.99 Budget Adj: 0.970 X (130.91 - 60.69) = 68.07 Domestic Hot Water 17.33 17.15 0.18 The budget shown to the left has been increased using Totals 68.07+ 58.95 = 127.02 97.97 29.05 this Budget Adjustment based upon Existing building information shown on the C -2R which follows this form. INFORMATI Conditioned Floor Area: 1,312 Floor Construction Type:XQ Slab Floor Building Type: Single Fam Detached [] Raised Floor Building Front Orientation: (South) 180 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 11,808 Number of Stories: 1 Slab Floor Area: 1,312 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area living 7nnP 1 312 11 AOR 1 on Cnnditinned Sc thank _Z n/a solar OPAQUE SURFACES Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C-210% Christine Sanchez 3/6/2002 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J_ Window-Eront-(South) 43_0_ 0_870_ _07.0 X80_ -90. Double -Mil -Uncoated -Default_ 2 Window Front (South) 46.4 0.870 0.70 180 90 Double Mtl Uncoated Default 3 Window Front South 6.8 0.720 0.73 180 90 Double Mtl Uncoated Default 4 Window Rear (North) 4.1 0.720 0.73 0 90 Double Mtl Uncoated Default 5 Window Rear (North) 7.5 1.280 0.80 0 90 Single Mtl Uncoated Default 6 Window Rear (North) 40.0 1.250 0.80 0 90 Single Mtl Uncoated Default 7 Window Rear (-N-o , 9.0 1.280 0.80 2 90 Single Mtl Uncoated Default 8 Window Rear (North) 9.0 1.280 0.80 0 90 Single Mtl Uncoated Default 6 Window Right (East)_ �4.0 250 0.80 90 90 Single Mtl Uncoated Defawlt_ J0. Window Right (EasSy 40.0 1.250 0.80 90 90 Single Mtl Uncoated Default 11 Window Ri tit-ffastj Bug Screen 13.4 1.190 0.83 90 90 Single Mtl Uncoated Default _LiyingZone _LIMN -Zone Living Zone _Ljying Zone Living Zone Living Zone Living Zone Living Zone Livina Zone Living Zone -Liybg Zone INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.5 7.1 4.0 0.1 4.0 4.0 2 Bug Screen 0.76 4.0 5.1 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.2 1.2 2.0 0.1 2.0 2.0 _ 4 Bug Screen 0.76 _ 5 --Bug Screen 0.76 3.0 2.5 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.8 6.0 2.0 0. - 2.0 7 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.8 6.0 8.0 0.1 8.0 _ 8.0 10 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 1.0 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 15 1 Computer Method Summary (Part 3 of 3) C -2R Christine Sanchez 3/6/2002 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (so (in.) Cap. Inside Location Cond. Form 3 Reference R -Val. Comments Concrete —H—Qav_yweight x.312 _3-50 98_ _0 98. n/a 0-Lmng_ZoneLSJab_on_Gtade PERIMETER LOSSES Minimum Distribution Type F2 Insulation Efficiency Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 165 0.76 0.0 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80° AFUE Ducts in Attic 2.1 Setback Livina Zone Insul. Hydronic Piping Pipe Pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 10.0 SEER Ducts in Attic 2.1 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas_ Standard 1 40—MQ 50 0.53 -n/-a 12 1 For small gas storage (rated input —, 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 03/06/02 22:31:56 Run Code: 1015482716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:9 of 15 Computer Method Summary (Addendum) C -2R Christine Sanchez 3/6/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. I HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1312 sqft Exposed Slab Floor, 3.50" thick at Existing Living/Addition HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:10 of 15 1 Computer Method Summary (Part 1 of 3) C -2R C ristine Sanchez Project Title 3/6/2002 Date 53-980 Fisenhnwer Drive La Qtjinta Project Address Building Permit # Insu-Form Inc_ (760) 324-0216 Documentation Author Telephone Plan Check/Date Computer Perf rmance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.40 6.59 -3.19 Space Cooling 39.57 106.78 -67.21 Domestic Hot Water 17.72 17.54 0.18 Totals 60.69 130.91 -70.21 GENERAL INFORMATION Conditioned Floor Area: 1,272 Floor Construction Type: X❑ Slab Floor Building Type: Single Fall) Detached ❑ Raised Floor Building Front Orientation: (South) 180 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 10,176 Number of Stories: 1 Slab Floor Area: 1,272 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Wall 244 n ngg lap go nnnr 2n n 387 1 an gn Wall 64 a nAR 270 90 Wall 366 _ n ngs 0_ 90 Wall 63 _ n.nga 90 90 Roof 1 9_72 — n n51 t an n Solar Gains Thermostat Vent Zone Type Type Hgt. Area rnnriitennPri SPthank —2 n/a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 15 1 Comauter Method Summary (Part 2 of 3) C -2R Christine Sanchez 3/6/2002 Project Title Date FENESTRATION SURFACES 1 2 3 4 5 6 7 8 9 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 2.0 0.1 2.0 2.0 2.0 0.1 U- 2.0 Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments A_ Wind.aw_Eront South) X0_0_ --L28.0_ -0-80_ x_8.0_ _9D Singte_M l -Uncoated -Default_ -Living_Zone 2 Window Front (South) 32.0 1.280 0.80 180 90 Single Mtl Uncoated Default Living Zone 3 Window Rear (North) 7.5 1.280 0.80 0 90 Single Mtl Uncoated Default Living Zone 4 Window Rear (North) 40.0 1.250 0.80 0 90 Single Mtl Uncoated Default Living Zone 5 Window Rear(North) 9.0 1.280 0.80 0 90 Single Mtl Uncoated Default Living Zone 6 Window Rear(North) 9.0 1.280 0.80 0 90 Single Mtl Uncoated Default Living Zone Z Win w i h1 40.0 1.250 0.80 90 _90 Single Mtl Uncoated Default Living Zone 8 -(East) Window Right (East) 40.0 1.250 0.80 90 90 Single Mtl Uncoated Default Living Zone 9 Window RigLit_(East)_ 13.4 1.190 0.83 90_ 90 Single Mtl Uncoated Default Living Zone INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 2 3 4 5 6 7 8 9 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 01 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 4.0 8.0 3.0 2.5 6.8 6.0 3.0 3.0 3.0 __u 6.8 6.0 6.8 6.0 6.8 1.0 Len. Hgt. LExt. RExt. 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 01 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. I EneravPro 3.1 By EnergvSoft User Number: 2655 1 Job Number. Paae:12 of 15 1 Computer Method Summary (Part 3 of 3) C -2R Christine Sanchez 3/6/2002 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Distribution Type Type (furnace, heat Efficiency and Location F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter165 2.1 wetback Living Zone 0.76 0.0 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments CQntral Furnace 78°_/ A� 1�E Ducts in Attic 2.1 wetback Living Zone Pipe Hydronic Piping pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments -5 , it Conditioner 9.0 SEER Ducts in Attic 2.1 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact' 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gam Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.53 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 03/06/02 22:31:56 Run Code: 1015482716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 13 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Christine Sanchez 3/6/2002 SYSTEM NAME FLOOR AREA Living Zone 1,312 ENGINEERING CHECKS 11SYSTEM LOAD INumber of Systems 1 11 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sgft) 53.4 Cooling System COIL HTG. PEAK Output per System I Sensiblel 48,000 Total Output (Btuh) I Sensible 48,000 Total Output (Tons) 1,581 4.0 Total Output (Btuh/sqft) 0 36.6 Total Output (sgft/Ton) 0 328.0 CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 26.0 OF 69.1OF 69.10F Outside Air 0 cfm 69.1 of 1,740 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 2,089 31,617 2,876 879 33,648 0 1,581 1,682 0 0 0 0 0 0 0 0 0 1,581 1,682 34,778T 2,876 1,740 BDP CO. 561AJ048-" 29,4991 15,231 1.33 435.0 o.o Total Adjusted System Output29,499 15,231 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm 106.6 of Supply Fan Heating Coil 1740 cfm 11.0/77.4OF 78.8/67.6 Outside Air 0 cfm 78.8/67.6 of }% Return Air Ducts 4 70,000 70,000 Jan 12 am Supply Air Ducts 105.7 of ROOMS 70.0 of 78.8 / 67.6 of■ 63.0 / 62.0 of Supply Air Ducts 63.9 / 62.3 of 58.0% R.H. ROOMS 78.0 / 67.3 of Supply Fan Cooling Coil 1740 cfm Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:14 of 15 IROOM LOAD SUMMARY PROJECT NAME Christine Sanchez DATE 3/6/2002 SYSTEM NAME Living Zone FLOOR AREA 1,312 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Existing Living/Addition 1 2,089 31,617 2,876 2,089 31,617 2,876 879 33,648 PAGE TOTAL 1 2,089 31,617 2,876 879 33,648 TOTAL 1 2,089 31,617 2,876 879 33,648 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:15 of 15