Loading...
001357 (SFD)PERMIT APPLICATION City of La Ouinta Department of Building and Safety This permit becomes void if work not commenced within 180 days from date of issuance. OR, if work has been suspended or abandoned for a period of 180 days: LICENSED CONTRACTORS DECLARATION: I hereby affirm that I am licensed under provisions of Chapter 9 • (commencing with Section 7000)'of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic Number Date Contractor. . .�/__ OWNER -BUILDER DECLARATION: I hereby affirm that Iain exempt from the Contractors License Law for the following reason (Seca 7031.5. Business and Professions Code: Any city or county.which requires a permit to ' construct, alter, improve, demolish. or repair any structure, prior to its issuance, also requires the applicant for ..such permit to file a signed statement_that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 (commencing with section 7000) of Division 3 of the Businessand Professions Code) or that he is exempt therefrom and. the.basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500.): " O 1, as owner of the property, or my employees with.wages as their sole compensation, will do the work; and the structure is not intended or offered for sale (Sec. 7044, Business -and Professions Code: The Contractor's License Law does not apply to an owner of property who builds, -or improves thereon, and who does such work himself or through his own employees. provided that such improvements are not intended or'offered for saleAf, however, the _building or improvemnt is sold within one year of completion, the owner -builder will have the burden of proving that :he did not build or improve for the purpose of sale.). 0 1. as owner of the property, am exculsively contracting with licensed contractors to construct the project (Sec. 7044. Business and Professions Code: The Contractor's -License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensedpursuant to the Contractor's License Law.). 0 "1 am exempt under Sec. A. 8 P.C. (Attached Certificate). Date Owner" WORKERS' COMPENSATION DECLARATION: I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Workers' Compensation Insurance .'Or a certified copy thereof (Sec, 3800. Lab: C.). Policy No. Company ' 0 Certified copy is hereby furnished. 0 Certified copy is filed.with the City Building Inspection Department or City Department. Dater Applicant APPLICANT NAME (L, F. MI) Dessert Design � rign t ADDRESS P.O. II= 1420 CITY/COMMUNITY/STATE/ZIP la Qu njita., CA 92253 JOB SITE ADDRESS/SPACE C A4 -33f 95`(;tii er%awer CITY/COMMUNITY/STATE/ZIP Id Quint. '•, C 92253 �i,TWN SOK ,74 PAG ,,.2 PRC �� C 303.40 RNG SE S TRACT LOT 5.29 MOD se + TRACT NAME ' OWNER NAME (L. F. MI) AW . `_vi CONTRACTOR -FIRM NAME apple ADDRESS Qbwe CITY/COMMUNITY/STATE/ZIP abme PHONE* LICNC / ARC/ENG FIRM NAME ADDRESS CITY/COMMUNITY/STATE/ZIP - .PHONE . TOTAL' FEE LICNC M ' USE OF PERMIT Single family dwelling BL. ZON FSB SSB SSB RSB OFC ' ZONE ORD1" LOT SZ END SIDE CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE: This section need not be completed if the permit is for one hundred ($100) o. less. I certify that in the performance of the work for -which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Applicant NOTJCE TO APPLICANT: If, after making this Certificate of Exemption, you should become subject to the Workers' Compensation provisions of the Labor Code; you must forthwith comply with such provisions or this permit shall be deemed revoked. DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION: O 1 hereby certify that no excavation five (5) or more feet in depth into which a person is required to descend, w ill be made in connection with work authorized by this permit, and that no building structure, scaffolding, falsework, or demolition or d smantling thereof, will be more than thirty-six (36) feet high. (Chap 3.2. Grp 2?Art 2, Sec 341, Title 8, 0 As owner -builder, I will not employ anyone to do work which would require a permit from the Division of Industrial Safety; as noted above, unless such person has a permit to do such work from that division.. 0 Division of Industrial Safety Permit No. Date Applicant CONSTRUCTIOA LENDING AGENCY: I hereby affirm that there is a construction lending agency fortheperformance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address F .1 certify that I have read thi`s application and.state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives. of this county to enter upon the above-mentioned property for inspection purposes. Signature of Applicant or Agent Date CERTIFICATE'OF COMPLIANCE'AND AUTHORIZATION OF ENTRY: I certify I have read this application and state that the information given is correct. I agree to comply with all state laws and county ordinancesrelating to buidling . constructs n• and authorize'a'representative of the City of La Ouinta Department of Building and Safety to enter upynihe/�ropgrty for whichhII �hi0e applied for this;permit foretlie purpose of making inspections. Signature Applicant or�Agent J Date Print Applicant/Agent Name APPL/PRMT> DALE 4-25-8s s.F.D. Premit to construct 1440 sq. ft. of house 200 sq. ft.: of pozch and 440sq. ft. as Per aPp Pis- Mach. Fee' 30.00 1Plan Citieck Fee 303.40 C oust. Fee 361.00 Elect. Fee 68.10 941 Fee 5.29 Plumbing Fee 83.00 Prop. Devel. 450.00 1,300.79 s (250.00) DEPOSIT PAID '1,050.79 TOTAL' FEE _'on 74 A 0 8 9 f 2 - ll, - 'T. VALUATION 75,524.00 .N .en NO. OPERATION DATE INSPECTOR NO. OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS 1 Set Back33 Ventilation System 2 Ftgs & Frms 34 Plenums & Ducts 2A Slab Grade 35 Furnace Compart. 3 Steel 36 Inlets & Outlets 4 Grout Blocks 37 Combustion Air 5 Bond Beams .38 Compressor 6 Roof Deck 39 Appl. Clearance 7 Framing ` i 40 Fire Damper 8 Vents 41 Smoke Detection Device gr Garage Fire Wall 42 Commercial Hood 10 Fireplace P. L. ❑ 43 Final 10A Fireplace T.O. ❑ OP'N NO. ADDITIONAL INFORMATION , SEWAGE SYSTEM SIZE & LOCATION 11 Exterior Lath 12 Internal Lath p 12A Drywall 13 Finish Grade INSULATION Thick R Value 7A Walls (Batts) 12B Ceiling (Batts) 12C Ceiling (Blown) 14 Final PLUMBING APPROVALS 15 Ground Plumb 16 Water Piping 17 Rough Plumb .18 Vents 19, Sewage Disposal o2� 20 Sewer 21 Water Heater 22 Water Softener 23 Water Service 24 Gas Test 25 Final Tank Pit L. Line ELECTRIC APPROVALS I REAR OF PROPERTY LINE PSL P/ h STREET NAME 26 Power Pole y 27 Conduit 28 Service Entrance .29 Wiring 29A Grounding Wire 29B Bonding 30 Fixtures 31 Service 32 Final *%f1ED = o Desert Sands Unified School District y BERMUDA DUNES RANCHO MIRAGE 82.879 HIGHWAY 111 O INDIO, CALIFORNIA 92201-5678 • (619) 347.8631 INDIAN WELLS H PALM DESERT % LA QUINTA �o INDIO yo May -2,1985 City of La Quinta Department of Community Development 78-105 Calle Estado La Qui'nta, CA 92253 Re: 54395 Eisenhower Drive Gentlemen: The developer of the above referenced lot has mitigated its impacts on our overcrowded schools by payment of the amount of $628 per unit to be applied to the cost of district educational facilities made necessary by such new development. Sincerely, rL 1. 4 John D. Brooks Assistant Supe.rintende.nt Business Services JDB/crm Q Z O U W Cl) to Z O P U W y U Z O H U W COUNTY OF RIVERSIDE, DEPARTMENT OF HEALTH PERMIT APPLICATION FOR A SUBSURFACE DISPOSAL SYSTEM Applicant: Submit this form with three copies of a scaled plot plan drawn to county specifications required on the attached check list. A non refundable filing fee of $15 is required when the application is submitted. Check must be made payable to County of Riverside. N@ Mailing Address City' / 1 State ,- Zip Code Phone n c� r / !! i r/ �c✓ � � 4 V-1 *Property F(ddress *City_ or Community *Legal Description of Property (Lot, Parcel Map, Tract) X.L . `7' � /f c 7 G!e/Xcg `Assessors Parcel No. Water Serving Property From Lot size �;-„� �jc!� .k Ulf a r l � •� Signatufe of Applicant �, /' / Date *The above information must be verified from Building Application Staff Use — Do Not Write Below This Line Initial Date WQCB Clearance required Yes ❑ No ❑ l 3 f Soils feasibility report required Yes ❑ No ❑ Detailed boring report required Yes ❑ No ❑ �f Detailed contour plot required Yes ❑ No ❑ Comments: Soils or boring report by Date Approved by Date. Soils Map Page Soil Type Tract File No. Other _ Number of Bedrooms Septic Tank Size (gallons) Rate Required Type of System New Addition Replacement ❑ ❑ ❑ Leach line sq. ft. of bottom area trench Leach bed (sq. ft. of bottom area bed) Seepage Pit Diameter Number of Pits Seepage Pit Depth B.I. Total Depth of Pit r 6' Location of System f� _ Additional Requirements",.�"f: A permit is approved/denied for the design of a subsurface disposal system as indicated on the accompanied plot plan using the requirements set forth in Section B above. A building permit is necessary for the installation of the above designed system. Signature of Health Official Date Receipt No Issued By District: Riverside ❑ DISTRIBUTION: WHITE - Office File DOH SAN 122 (Rev 10/84) Indio ❑ - Hemet ❑ YELLOW - Applicant Date PINK - Building Dept. GOLDENROD - Pending File ,ry MAI 2 3 1S85 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPT 1731-A WALTER _STREET VENTURA, CALIFORNIA 93003 PHONE (805) 642-6727 May 17, 1985 Job No. B -15120-P1 85-5-205 Desert Design P.O. Box 1420 La Quinta, CA 92253 Project: 54-395 Eisenhower & 54-895 .Ave. Al.verado La Quinta,- Ca Subject: House Pads Report of Field Densities On April 29, 1985 and May 2, 1985 a representative of our firm per- formed density tests on the fill placed in the building areas on the above referenced project. Tests were"performed at random lo- cations in accordance.with ASTM D 2922-81 and ASTM D 3017-78 Nuclear Density Test Procedure. Tests performed as per authorization of Desert Design. The estimated locations of the tests are presented on the attached plan with their results being summarized.on the attached test re- port sheet. A -'total of four (4) density tests were performed. Test results indicate a minimum' -of "ninety percent (90y)of relative compaction has been obtained within the areas tested. The maximum density -optimum moisture was determined in the laboratory in ac- cordance with ASTM D .1557-78, Method A, five (5) layer curve. Class ifitation Tan silty fine to coarse sand THOUSAND OAKS (805) 495.8484 VENTURA (805) 642.6727 BAKERSFIELD (805) 327.5150 Maximum Density -Optimum Moisture 120.3 pcf 10.6% SANTA BARBARA (805) 966.9912 LANCASTER (805) 948-7538 PALM SPRINGS (714) 328.9131 SAN LUIS OBISPO (805) 544.6187 May 17, 1985 LIMITATIONS Job No. B -15120-P1 85-5-205 The compaction operations were completed at the time our personnel were called. to the site. The test.results summarized in this report present the moisture and density only at the locations and.depth tested on the specified date. The summarized field and laboratory tests were performed in accordance with engineering principles generally accepted at.this time.and location. No opinion is expressed as to the uniformity .of the material, compaction nor adequacy of the material to perform -its intended function. No guarantee or warranty of the contractor's work is made or implied. Respectfully submitted, BUENA ENGINE ,.I PaAl Aorr.:an G. Jack on, Jr. NGJ/REB/kls . Copies: 4- Desert Design 2- City of La Quinta 1- P.S. file 1- Vta. file Reviewed and approved Raym nd E. Brannen C.E. 28966 BUENA ENGINEERS, INC CONTRACTOR: ADDRESS: REPORT OF RELATIVE CC APACTIONS Job No. B -15120--P1 DAT Iii ay 17, 1985 Report No. 85-5-205 Eisehower & Ave. Alvorado JOB& LOCATION: La Quinta, CA . TEST NO. DATE DESCRIPTION q MOISTURE DRY DENSITYRELATIVE MAXIMUM TESTED IN PLACE IN PLACE COMPACTION DENSITY EISENHOWER 54-395 1 4-29-85. 0.5 from grade Per Plan 8.5 108.0 90 120.3 2 4-29-85 Finish Grade II 8.8 i10.0 91 120.3 Ave. ALVORADO 54-895 3 5-02-85 1.0 from grade if 9.8 109.0 90 120.3 4. 5-02-85 Finish -Grade " 8.0 108.3 90 120.3 WE CERTIFY THAT THESE TESTS WERE PERFORMED IN CONFORMANCE WITH COPIES: BUENA ENGINEERS, INC. T I TLF. 24 FEE I\AC=R"Ne C;AIL__Q::�1._J1__.A-1-' 1 n-- P4 AF:;z1-A 1. tS JOHN H. . HA&ER, CIVIL ,ENG I NEER, PALM SPRINGS LATITUDE 33.8 WINTER TEMP. 31 DEG. SUMMER TE_IlP. 1.1.0 DEC OWNER __-1!:!-5_e'�'_70'-__ C!/Zv / s� _ z e?1-*77 ell_ JOB SITE LOCATION_�_:/C _� % _!'J�-Z'% AREA BLDG 1440 SO. FT.'. PERIMETER 152 SO. FT. INSULATION R VALUES ... SLAB.0 ... CEILING '•8 ... WALL 1 1 . . AREA NORTH WINDOWS 47 SQ.FT. PERCENT OF AREA :11.267-89 AREA EAST WINDOWS 40 SQ.FT. PERCENT OF AREA 2.777711 AREA SOUTH WINDOWS 18 SQ.FT. PERCENT OF AREA 1..25' AREA WEST WINDOWS 56 SQ.FT. PERCENT OF AREA. 111- 809 AREA SKYLIGHTS 0 SOFT. PERCENT OF AREA r) TOTAL WINDOW AREA 1.61. SOFT. PERCENT OF AREA 11.1806 THE U VALUE OF THE WINDOWS IS 1 . 1 (. 65= DUAL. PANE, 1. , 1. = F) I NGL..E PANE) THIS BLDG USES WHITE ROLLER SHADS ON WINDOWS (S.C. _ .41) THE TOTAL S.C. OF THE WINDOWS IS .�;8 SOUTH nVERHANG LENGTH 2 INTERIOR, THERMAL MASS AREA = 360 SO FT ATTIC AREA = 1440 SO FT INFILTRATION (STD 0.01.8, MED 0.014, TIGHT 0.012') - .01.4 l HEATING LOSSES FOOTING LOSSES... 6639.36 BTU CEILING LOSSES ... 1.421.77 F+TU WINDOW LOSSES... 6906.9 RTL) WALL LOSSES.... .+^91.6 PTU INFILTRATION LOSSES„.. 6289.92 BTLI TOTAL HEAT LOSSES FTU/HR... 24549.6 GAS FLIRNANCE SIZE 66950.9 BTU OR 45,100 BTL) COOL_ I NG LOSSES ` FOOTING LOSSES... 6809.6 BTU CEILING LOSSES.... 1458.23 BTU WINDOW LOSSES... 11447.9 BTU WALL LOSSES.... 3:::76 BTU INFILTRATION LOSSES... 6451.2 PTU NO. OF PEOPLE... 5 C:OOI_ING LOSSES... 2000 KITCHEN... '1500 STU DUCT LOSSES INCLUDED IN TOTAL I.TOTAL,COOLING LOSSES 33042.9 BTU a COMPLIANCE CHECK LIST PER DESIGN DATA | - -- -- --'--'� '- ----'-- SLAB ON GROUND, WALL INSULATION, CEILING INSULATION, . � ATTIC, NORTH WINDOWS GLAZING EAST WINDOWS GLAZING SOUTH WINDOWS GLAZING WEST WINDOWS GLAZING SKYLIGHT GLAZING EAST SHADING COEFFICIENT SOUTH SHADING COEFFICIENT WEST SHADING COEFFICIENT NORTH SHADING COEFFICIENT SKYLIGHT SHADING COEFFICIENT INFILTRATION THERMAL MASS 360 SQ.FT' SOUTH OVERHANG -4 POINTS -6 POINTS 0 POINTS 4 POINTS GAS FURNANCE 75 SE AND REFRIGERATION COOLING 0 POINTS -1 POINTS 2 POINTS -4 POINTS 0 POINTS -2 POINTS 0 POINTS -4 POINTS ' 3 POINTS 0 POINTS -1 POINTS 8 POINTS 0 POINTS THE EER OF THSCOOLING SYSTEM IS 8.7 COOLING 6 POINTS THE ALLOWABLE POINTS PER AB 163 IS -4 FOR THIS~AREA 15 THE TOTAL POINTS ARE 1 THE FOLLOWING MANDITORY FEATURES/DEVICES ARE REQUIRED PERCAC TITLE 24 ^� INSULATION AS SPECIFIED; PER MANUFACTURES LABLE INFILTRATION CONTROL. DOORS, WINDOWS FULLY WEATHERSTRIPPED OPENINGS CAULKED AND SEALED AROUND JOINTS IN WINDOW AND WALL SOLE PLATES ANP ELECTRlC OUTLET GASKETS ON ALL EXTERIOR WALLS MANUFACTURED DOORS SHALL MEET APPLICABLE STANDARDS BACK DRAFT DAMPERS ON EXHAUST FAN FIREPLACES MUST HAVE TIGHT FITTING, CLOSEABLE DOORS COVERING FIREBOX PROVIDE COMBUSTION AIR INTAKE DUCTS (6 SQ. IN.) WITH TIGHT FITTING DAMPER DUCTS; BUILT PER CHAPTER 10 U.M.C. GAS FURNANCE SIZED TO 1.3 DESIGN LOGS + 10 BTi>H PER SQ. FT, OR 45,000 BTU SETBACK THERMOSTATS SHALL HAVE AUTOMATIC SETBACK CAPABILITY /2 PERIODS PER 7,1 WATER HEATER TO HAVE R-12 INSULATION WRAPPING, AND R-3 ON FIRST 5' OF PIPE NAT. GAS STOVES SH HAVE CONT. BURNING PIOLTS LIGHT IN KITCHEN~A Tu0TO BE FLOURECENT, EXCEPT BATH MIRROR KIT SINK, An|� ���� CERTIFIED(Q, ~��� _(�����_��_�����-�___________- HN H. HACKER, R.C.E. 14614 a �I -T- I— r=-- a7: ---% ��F::---: ��IL— 0-- af-N *-T' 1 "-. p,0 4"."b��9N �!.* —5 JOHN H. HACKER, CIVIL ENGINEER, PALM SPRINGS LATITUDE 33.8 WINTER TEMP. 31 DEG. SUMMER TEMP. 110 DEG � OWNER_______________________________________ JOB SITE LOCATION_____________________________________ _ ` AREA BLDG 1440 SQ. FT. PERIMETER 152 SQ. FT. INSULATION R VALUES ...SLAB 0 ...CEILING 38 ...WALL 11 ... AREA NORTH WINDOWS 47 SQ.FT. PERCENT OF AREA 3'26389 AREA EAST WINDOWS 40 SQ.FT. PERCENT OF AREA 2'77778 AREA SOUTH WINDOWS 18 SQ.FT. PERCENT OF AREA 1.25' AREA WEST WINDOWS 56 SQ.FT. PERCENT OF AREA 3.88889 AREA SKYLIGHTS 0 SQ.FT. PERCENT OF AREA 0 TOTAL WINDOW AREA 161 SQ.FT. PERCENT OF AREA 11.1806 ` THE U VALUE OF THE WINDOWS IS 1.1 (.65= DUAL PANE, 1.1= SINGLE PANE) THIS BLDG USES WHITE ROLLER SHADES ON WINDOWS (S.C. = .41) THE TOTAL S.C. OF THE WINDOWS IS .08 SOUTH OVERHANG LENGTH 2 INTERIOR THERMAL MASS AREA = 360 SQ FT ATTIC AREA = 1440 SQ FT INFILTRATION (STD 0.018, MED 0.014, TIGHT 0.012) — .014 . HEATING LOSSES FOOTING LOSSES... 6639.36 BTU CEILING LOSSES... 1421.77 BTU WINDOW LOSSES... 6906.9 BTU WALL LOSSES.... 3291.6 BTU INFILTRATION LOSSES... 6289.91 BTU TOTAL HEAT LOSSES BTU/HR... 24549.6 GAS FURNANCE SIZE 66950.9 BTU OR 45,000 BTU COOLING LOSSES FOOTING LOSSES.'' 6809.6 BTU CEILING LOSSES..' 1458.23 BTU WINDOW LOSSES... 11447.9 BTU WALL LOSSES.... 3376 BTU INFILTRATION LOSSES... 6451.2 BTU NO. OF PEOPLE... 5 COOLING LOSSES..' 2000 KITCHEN... 1500 BTU DUCT LOSSES INCLUDED IN TOTAL TOTAL -COOLING LOSSES 33042.9 BTU A CCMPLUMt CBYVILIS'L MRA 2 yor Low-a.ise &ftsidential Buildings (except hotels and motels) Step 1: Enter on the form the values for each measure from your building plan and specifications sheet. Step 2: Enter points on this page while Working through the point system in Part 3. Building Shell Measure *Total Floor Area . ./�� f t2 1. Slab -on -Ground Perimeter ft; Depth in R- 2 e Raised Floor R -Value . . . . . . . . . . . . . . e R 3. Ceiling Insulation or Construction Assembly, R-Value.R- 38 4. Wall Insulation or Con.truction Assembly, R -Value R- f/ Glaring Total 2 Floor, Area Single Double' Triple 5. Korth -Facing . e Z 07 ft2 ft2 ft2 6e [sat -Pacing . . . +X p ft2 ft2 ft2 7. Sou t h -F aci ag ... —Xf t 2 ft2 f t 2 Be West -Facing . —Z ft2 ft ft 9.. Skylight . . . . . �2 4D ft2 ...___.—ft2 . . . . . . 10. Shading Coefficient (exclude overhang) a. East . . e . * . . . e . . e . . .-32 SC . be South . e e . e e e e e e e . 7-7 —z SC . . . . . . . c e West . * , . . . * e . . . e e . 2 SC d. Skylight . . . . . . . . . . . . . SC . 11. Horizontal South Overhang Length . . * . ft . . . . . . . 12. Movable Insulation, % Floor Area . . . . �X 13. Infiltration (indicate Standard or Tight) 14. Thermal Mass Exterior Wall Thermal Mass 2 Area, Heat Capacity, R -Value . . 366.ft , HC, R - Interior Thermal Mass Area, Heat Capacity, R -Value . . ft2, HC; R - HVAC System** 15. Gas Furnace Without Refrigeration Cooling SE (Seasonal Efficiency) 16. Heat Pump (Energy Efficiency Ratio) EER 17. Gas Furnace with Refrigeration Cooling (Seasonal Efficiency (SE), Seasonal Energy '� Efficiency Ratio (SEER)] * . .•. . . . � SE 8 7 SEER 18. Active Solar (Net Solar Fraction, %) - ZNSF L9. Zonally Controlled Electric Resistance Space Heating (Yee/No) )omestic Water.Heating** 0. Solar With Gas Backup (Net Solar Fraction, 2) . . . NSF 1.• Othei Water Heating (Describe type) • pint System Compliance Total (must be greater than or equal to --W) "Chec T st terns; not a point system measure. *Attach documentation for efficiencies and NSF. -39 ECIf14 Points =-T s Z 40 4 1-4yt