003545 (SFD)Building
Address
Owner
Mailing
Address
City
Contractor
Address
QUA&h'
P.O. BOX 1504 No 003545
78-105 CALLS ESTADO
54-4555 Eisenhower LA QUINTA, CALIFORNIA 92253
Western American Const. Co.__-
-BUILDING:. TYPE CONST. OCC: GRP:
P. 0.. Box 1379 A.F..Number 774-252-023
Zip Tel.
I... 92253 77�..-538 Legal Description
Project Description Si4iale Famlly DWalling
Gary Reynolds
P. o.. not $07
City' Zip
Tela
Thi ossand Pa3.m 922763
.
State Lic.
City
& Classif. 469157
Lic. #
Sq. Ft. 1812 No. No. Dw.
Size- Stories Units
Arch., Engr... .
Designer
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Address
Tel.
`
City
Zip
State
_
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9'(commencing with Section
7000) of Division 3 of the Business and Professions Code; license is in full force
and my and
effect. T
SIGNATURE x / - 6 % li !DATE
—
` OWNER -BUILDER DECLARATION
Estimated Valuation
I hereby affirm that I am exempt from the Contractor's License Law for the following
'city
S43 949
reason: (Sec. 703,1. 5, Business and Professions Code: Any Or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he. is licensed pursuant to
- -
PERMIT AMOUNT
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section •7000) of.
'Division 3 of the Business and Piofessidns Code, or that. he is exempt.tnerefrom, and .the basis
for the alleged exemption. Any violation of Section 7031.5 by 'an applicant for a permit
Y
,
Plan Chk. Dep. - $` 0
w
subjects the applicant to a'civil penalty of not more than live hundred dollars ($500).
PI hk
Plan
a C Ba .,� 108
O I, as owner of the property; or,my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
• .52
Const. ��g
Professions Code: The Contractor's License Law does not apply to an owner of property who
"own
+
builds or improves thereon and who does such work himself or through his employees,
Mech. 36.00
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
Electrical - - 84.15
. of proving that he did not build or Improve for the purpose of sale.) _
i' O I, as owner bf.the property, am exclusively contracting with licensed contractors to con-
. Plumbing 1-27.00
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
_
S.M.I. 6.55 '
such projects with a contractor(s)-licensed pursuant to the Contractor's License Law.)
Grading 20-.00
.0.1 am exempt under Sec. B. & P.C. for this reason
"•
Driveway Enc. 20.00
Date Owner _
Infrastructure
WORKERS' COMPENSATION DECLARATION
' I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No: Company
O Copy is filed with the city. . ❑ Certified copy is hereby furnished.
TOTAL S3 AA2..80 A;
CERTIFICATE OF EXEMPTION FROM
REMARKS
WORKERS' COMPENSATION INSURANCE
.
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
,
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner -so as to become subject to the Workers' Compensation
Laws of California.
t J �� y `, �y y t- e��,
�/j, 1^wr6a ; t•r+X�,a •?110'9 r31i
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
ZONE: - BY:
,
subject to'the Workers' Compensation' provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
Minimum Setback Distances: -
Front Setback from Center Line
Rear Setback from Rear Prop. Line
CONSTRUCTION LENDING AGENCY
Side Street Setback from Center Line
I hereby affirm that there is a Construction lending agency for the performance of the
whic
• work for h this permit is issued. (Sec. 3097, Civil Code.) -
Side Setback from Property Line
Lender's Name
_ . Lender's Address
FINAL DATE INSPECTOR
This is a building permit when'properly filled out, signed and validated; and is subject to
expiration it work thereunder is suspended for 180 days. +:. .
1` " 87
1 certify that I have read this application and state that the above information is correct.
Issued by:' Date • Permit
1 agree to comply with all city and county ordinances and state laws relating. to building
construction, and hereby authorize representatives of this city to enter the above-.
mentioned property for inspection purposes.
Validated by:
Signature of, applicant Date
Mailing Address.
Validation:
City, State, Zip
HARD COPY
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBI!,J9 FEES
1ST FL. SO. FT. ® $
UNITS
SLAB GRADE
ROUGH PLUMB.
BONDING
YARD SPKLR SYSTEM
2ND FL. SO. FT.
FORMS
$EWER OR SEPTIC TA
ROUGH WIRING
MOBILEHOME SVC.
BAR SINK
POR. SO. FT. ®
S (ROUGH)
METER LOOP
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
GAS (FINAL)
TEMP. POLE fq
DRAINAGE PIPING
CAR P. SO. FT. ®
GROUT
WATER HEATER
WALL SO. FT. ®
FINAL INSP.
DRINKING FOUNTAIN
SO FT ®
WATER SYSTEM
URINAL
ESTIMATED CONSTRUCTION VALUATION $
_$
WATER PIPING
NOTE: Not to be used as property tax valuation
ROOFING Z
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FLOOR DRAIN
MECHANICAL FEES
REMARKS:
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM. B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
SO.FT.GAR ® 3/ac
HOUSE SEWER
GAS PIPING
PERMIT FEE
—[—�MICRO
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
$EWER OR SEPTIC TA
ROUGH WIRING
DUCT WORK
ROCK STORAGE
Or
FOUND. REINF. Z��
S (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE fq
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR. FINALINSP.%r17
FRAMING 3J yyg� FINAL INSP.
ROOFING Z
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
IIrA ( �7 /� �ti QGL/j
G
REMARKS:
FINAL INSPECTION
CERT. OCC. )
FENCE FINAL
GARDEN WALL FINAL
INSPECTOR'S
Z
O
U
W
U)
C0
Z
O
FZ
U
LU
U)
rw
CrZ
L
Z
O
F-
C)
W
U)
iii•' ��.j� ,'. F'. '-r .. ;="; .: w ` �•+t- - "-.*1"� t ". ti ',w, . '� � .q:,.r� �.t�Y 'len. r
2
COUNTY OF RIVERSIDE, ENVIRONMENTAL HEALTH SERVICES DIVISION
PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM — —
Applicant: Submit this form with four copies of a scaled plot plan (1.20 scale) drawn to County specifications required on the attached check list.
A non-refundable filing fee of $40 is required when the application is submitted. Check must be made payable to the County of Riverside.
t N C�� Lk Building Department Application Log #
Name (Owner. Agent. Contractor. Etc.)
Mailing Address
City
State
Zip Code
Telephone
'Job Property Address
�7's
'City of. Community
'L-egal-Deseuptiosi eo_Properiy. (Lot. PM. TR)
his r-�.lza
L.4
'Assessor's Parcel No
Water Agency or Well
�9,A
�j,4 y A.N.s� ( r ` v�
Lot Size
Use of PermitPlanning Case M
SPD. MH Site Preparation Etc.
Sigoblure of Apphca Dale
1 'The above information must be verified from Building Application
STAFF USE — DO NOT WRITE BELOW THIS LINE
I ilial Date
Certification of Existing S.D. System required. ❑ Yes No A, t 2''? Ci
WOCB Clearance required. ❑Yes No
Soils feasibility report required. ❑ Yes No
Special feasibility boring report required. ❑ Yes No
Detailed contour plot plans required. ❑ Yes No
Staff Specialist approval required. ❑ Yes No Lot Inspection Date
Soils/boring report by C N Project # Date
Soils Map Page Soil Type Approved by Date
Type of System:
No. of Bedrooms
(1) Septic Tank
Soil Rate Required
❑ Existing ew ❑ Additional ❑ Replacement
I �\MulZ��lN X
�O�C-7 Gals.
9a \ �'2
(2) Leach line s
(Bottom nch area)
Sidewall allowance /
ft. rock/- Sq. Ft.
Install—Line(s) �F I, - Long,
Ft. wide wi min.—inches n. inches
Leach bled Sq.
Ft. of'bottom
per running ft. .U -,/N/A
rock below drain lines
area
Leach lines/bed-special design for slope:
(3) Pit Diameter
No. Pits
Pit BI
Seepage Pit total depth t
Applicablef
Overburden
❑ 5' C 6'
(
1
ILL
Max. allowable depth
N/A actor
1
ail a; •A la() - C;K aCft Q G � ^
r
This application is rav d/denied for the design of a subsurface disposal system as indicated on the accompanieii plot plan using the requirements
set forth in Section B above. A building permit is necessary for the installation of the above -designed system.
Septic tank and sewer lines must be 50' from any wells
(2) Leach lines must be 100' min. from any wells including expansion area
<�(3_)7Seepage pits e 15o, mma.4rorkqny wells including expansion areala"r
Signature of Heatl icia " ' Date
RECEIPT NO. 2 Issued by \ �C� Dates
District: ❑ Riverside Indio ❑ Hemet ❑ Perris ❑ Rancho Calif. ❑ Blythe
Distribution: WHITE—Office file YELLOW—Applicant PINK—Bldg. Dept. GOLDENROD—Pending File
DOH SAN 122 (Rev 8187)
.
�,M
�=V"4401 CgSUNTY DWARTMMT OF 1sURLIC HEALTH
D9VtS OM OF
Food EstablWm..t x
Traifer Park Setvae�e Btapesaf
AA -#-t e_. .. _
GrHer,AL !�
o�vNc�:
t,nc.-.-AL M5G�lf
rcT
occuPtl\Ncy
zone:
�I.bG. SQ FT
fa' J�QgIVE
Q APPROVED
BY:
DATE:
RAL CC
-
OF�
°" '41 f✓ f
OFFICE OF
E. LEON SPAUGY
QCOMMISSIO`ER
,21
AGRICULTURAL COMMISSIONER
o? ,
c
JAMES 0 WALLACE
I�)
I
ASS:StA�t COMMISSIONER
'' '"
WEIGHTS & MEASURES
CLEMENT BE`VENISTE
SEALER
49-613 Hwy 86, Suite B-12
4'tv.1••'�
4 Y q J 8q
'Coachella, CA 92236
619-342-8291
DATE % .Z —
2 9- c 7 CASE NO. 6 7 2 5
DEVELOPER'S NAME:
li✓ Ram-�..., CP,+-, .o^,u� (e��.ai[�•
ADDRESS: %�• D ,fid X go 7
227
TELEPHONE: ( 61 y) 3 V 3 2K 7
_ -5-3 - 3 y O _
.5-3-- 32-0
ILI , , 4F -
Y, 4J --. , 6e,
Dear Developer:
S Y—'VS's- f�4�,,/�,
s- 3 - E Gs` a___L_�
f�
4L 44u-•� 6
After reviewing your landscaping plans, material listed
is not in/
violation of
quarantine laws governing the Coachella Valley.
If substitutions
do occur and
they differ from plant material listed, this office
must be notified
immediately.
Thank you for protecting and preserving the Coachella Valley's
pest -free environment.
Agricultural Ccmnis Toner's Office
cc: Indio and Riverside Office
PROJECT DATA SUMMARY
owner
i iCJllas �:A M \
system type
Form 1
checked by
date
documentation author date
SITE INFORMATION k -t
' Z�
OF
Heating Degree Day (from Appendix C) ..._ .....................................................
HDD
1
-day
Outside Design Temperature (from Appendix C or Appendix G) ......................
Tow
2
of
PROPOSED BUILDING ENVELOPE INFORMATION
Gross Floor Area if Low -Rise (from Calculations) ............................................
At
3
tt2
Gross Wall Area if High -Rise (from Calculations) ............................................
Aw
4
1112
Designed Glazing Area (from Calculations).......................................................
Ag
5 Z� Z
ft2
Basic Glazing Area 06%of Line 3 if low-rise or 40% of Line 4 if high-rise)........
Abg
6
ft2
Description of Assembly
J
Glazing
Ugl
7 `
Btu/ (hr•ft2•OF)
Ug2
8
Btu/ (hr.ft2 •OF)
Ug3
9
Btu/ (hr•ft2•OF)
Wall t
Uwl
10
Btu/ (hr •ft2 •OF)
Uw2
11
Btu/ (hr •ft2 •OF)
Uw3
12
Btu/ (hr. ft2 • OF)
UW4
13
Btu/ (hr• ft2 •°F)
Ceiling/Roof —
Ucl
14 �� Zq
BtL1/ (hr •ft2 •OF)
Uc2
15 ---Btu/
(hr•ft2•oF)
Floor
Lill
16
Btu/ (hr.ft2 •OF)
Uf2
17
Btu/ (hr .ft2 .OF)
PROPOSED SPACE HEATING SYSTEM (Chapter 7)
Gas Furnace
Building Design Hourly Heat Loss (from Form 2) .....................................
qh
18
Btu/hr
Maximum Allowed Bonnet Capacity. 1.5 x Line 18 ...............................................
19
Btu/hr
Proposed Furnace -
Make
Model Description
Rated Bonnet Capacity
Electric Resistance Alone
Electric Resistance Life Cycle Cost (from Form 5) ....................................
sLCCe
20
$
Lowest Life Cycle Cost of the Other Systems (from Form 5) ...................
sLCCwwest 21
$
Non•Depletable Energy w/Electric Resistance Back -Up
Percentage of Annual Heat Loss Met by Non-Depletable Energy
Source (from Calculations)...............................................................................
22
%
Heat Pump '
Percentage of Annual Heat Loss Met by Electric Resistance
(from Calculations)............................................................................................
23
%
PROPOSED WATER HEATING SYSTEM INFORMATION (Chapter 8)
Electric Reslstence Alone
Electric Resistance Life Cycle Cost (from Form 6) .................................
wLCCe
24
$
Lowest Life Cycle Cost of the Other Systems (from Form 6) ...................
wLCCO g 25
$
PROPOSED SWIMMING POOL HEATING SYSTEM INFORMATION (Chapter
9)
Solar Life Cycle Cost (from Form 7)................................................................
pLCCs
26
$
Natural Gas Life Cycle Cost (from Form 7) ......................................................
pLCCng
27
$
HOURLY AND ANNUAL
BUPLDING HEAT LOSS RATE
. Chedc One: Proposed Design
Standard Design -
FA 41,
esign
FAQ N L`( Qe!-S ►->�aiC
owner project
project location system type
accumentation autnor Gate
Form 2R
(8/81)
Enforcement Agency Use On
buy ding permit numoer
rneCKed by
ate
SITE INFORMATION
Heating Degree Oay (from Appendix) . ........ .... .. .. ..... . HOO ) Z K 0F• day
Outside Oesign Temperature (from Appendix) . . . . .. . . . . . . . . . . . TowpF
Outside January Mean Temperature (from Appendix) .... .. .. .. .. . TJan pF
PROPOSED BUILDING ENVELOPE INFORMATION
Grose Floor Area (from plans) ...... ................ .... . Af , 7� ft2
Gross Wall Area (from plans) .................. .. .. .. .. . Aw _ ft2
Oesigned Glazing Area (from plans) ................ .. .... . Ag 2\y h2
Basic Glazing Area (16% of Af if low-rise or 40% of Aw if high-rise) .. ..Abg 3 h2
HOURLY HEAT LOSS
DESIGN TEMPERATURE DIFFERENCE
For All Assemblies Other Than The Three Below ...7d F - of 6Th 1 � aF
Tow from above
For Insulated Floor Over Vented Unheated Space .......... Line 1 =2 QThl 2 of
For Uninsulated Floor Over Vented Unheated Space........ Line 2 - 5GF 'AThu 3 °F
For Slab -on around Floors ........... 71fF - 5`) of -AThs 4 I of
Tian from above
CONDUCTIVE HEAT LOSS Average U
of Assembly,
Area, ft2 or or F2 from GT hourly most
1Description of Assembly Length, ft Graph 4- from aboveloss q
Glazing j�"7-12- X �• x _ � a. L4 Btu/hr
X X in
Well 3 � . x, a 1 X L4 R LJ (A
Ceilitrg/Roof`— .3 y 71 0 Z' X _-'- Z73
X x 3
Floor-� = XX
X X==
Otho.
volume Subtotal 5 ( to/hr
"� QQ um o t e aoove q
INFILTRATION ...... ��� ft2 x 8.3��h X018 x�F in
fr
Al from aoove weignted om Th from
Average Table 3.7 Lina 1
Calling Heignt Qs Subtotal 7 CCCC to/hr
I ne 5 -1 no b
DUCT HEAT LOSS (Enter 0 if there are no ducts) .................. 0.15 x Line 7 8 ( L
TOTAL HOURLY HEAT LOSS, Q,. 9 to/hr
ne 7 • I in
ANNUAL HEAT LOSS, OL
g Ii pF 10 Btu/yr
of .day/yr xBtu/hr x 1 X 24 hr/day + 3 �A1 2y3
HOO' Hourly Heat Lou C from Ll Tn from
from above from Lina 9 Table 3-8 Line 1
1�7NL;%-iZ
S
-2—LA Z
31131
q�4l 1
3�Sz . AA
PROPOSED. CONSTRUCTION ASSEMBLY
BUILDING ENVELOPE COMPLIANCE
Check one and write In construction
assembly number below (e.g. Wall -1,
Roof -2, etc.)
ER W a I I-#
0 Roof -
0 Floor -
Sketch of Construction Assembly
Framing type: k_OoD -p
If wood complete the following
and adjust construction assembly
for framing:
Size: Z , X a
.Spacing-_ . O.C..
Indicate area, weight of
construction assembly, -and
appropriate factors below:
Wali: Area ft
Weight Ib/ft3
MCF
TDeq
Roof: Area ft2
Weight Ib/ft3
Mc
Ac
Floor: Area ft 2
(raised only)
Form 3
(NR -8/81)
List of Construction Components R -Value
2.
4.
5.
6.
7.
8. `
Outside Surface Air Film
Cooling Heating
Inside Surface Air Film' W 1'' .
Cooling Heating
Total Thermal Resistance (Rt) )Z' y j
Cooling Heating
U -Value (--<RT) , �0
Cooling Heating
Note: Total RT and U -Value must be adjusted for the effect
of framing when appropriate.
-��-PRGPOSED- CONSTRUCTION ASSEMBLY
BUILDING ENVELOPE COMPLIANCE
Check one and write In construction
assembly number below (e.g. Wall -1,
Roof -2, etc.)
0 Wall -
0 all-
® Roof-_
O Floor -
Sketch of Construction Assembly
Framing type:W001D
If wood complete the following
and adjust construction assembly
for framing:
Size: Z a X '
.Spacing. O.C..
Indicate area, weight of
construct/on assembly, -and
appropriate factors below:
Wall: Area ft2
Weight ib/ft3
MCF
TDeq
Roof: Area ft2
Weight Ib/ft3
Mc
Ac
Floor: Area ft2
(raised, only)
Form 3
(NR -8/81)
List of Construction Components R -Value
3. 1 4J CR
4��
5.
6.
7.
8.
Outside Surface Air Film
12S
Cooling
Heating
Inside Surface Air Film
Cooling—
Heating
-,-
3
Total Thermal Resistance (R.T)
===Ljvt
1
Cooling
Heating
U -Value (t41 C l .1
, alsa
, O
Cooling
Heating
Note: Total RT and U -Value must be adjusted for the effect
of framing when appropriate.
s. � C hi `��►-�
BUILDING DESIGN AND EQUIPMENT SUMMARY
project title climate zone
pfolect address
\ l project owner
documentation author date
Form 2
page 1 of 2
plan Check/pefnl,t number
CneCked by
date
X_L_ �__ A4CNj1w I'4N1-`XZ7 Enforcement Agency Use Only
Comollance method (preScrintive or oerformance. describe)
BUILDING
B-IYELDtz oESI(�,kI
Description of Item Dimension
ft2
1 Q\ S<-
.Zg.R _'�..]rl
$ ftp
Total Floor Area ft2
Type 3
—.A ICW1
Ho `'� �� F= ?t-0
1. Floor:•
Slab Perimeter, Type 1
ft
A-lr\G
ft
Raised, Type 1 T '`2 s- O 1��C '` C ��1t3� FZ — 9 _ ftp
Type 5
Type 2 CO 'VPR-t,0 QN W> .. YA C ft2
2 Ceiling:
Type 1 -z'g
I �� V L . 4.�1 `�'� -ZZL.P , na
Type 2
fts•
3. Wall:
Type t
fe
Type 2
fta
✓ 4. Glazing:
West, Type 1 un
?,A�.1 �. y ��' % gq ft2
Type 2
V `
e ft,
�'�
North. Type 1
% ft=
Type 2
East. Type 1
y. _
fta
Type 2'/._
South, Type 1 '��-'
/� �� % LA-11fe
Type 2
?% fe
Skylight, Type 1
C fe
Type 2
_SC ft"
5. Shading Coefficient. West P�
�f
l' `''" ' S i '�� •�'�� Sc
v
NorthSc
Z.� 1 E n tt Il �/ Z►Z y. �lj Sc
South SC
6` Horizontal South Overhang ^S� 13' ft
.7. Movable Insulation °/. ft2
8. Infiltration Control
9. Thermal Mass:.
`Ew
Type 1 \ �� �� R
-' a s. 1
ft2
Type 2
.Zg.R _'�..]rl
$ ftp
Type 3
—.A ICW1
fe
1, Oa q
Type 4
_.R _._.}IG MC
fta
Type 5
____w ___w
ft=
Point Total This Page
W
1/83 — 420 — CCC
284-66 (2A3)
Points
C
-�c
7 g E12 & ES12 SERIES ELECTRIC FURNACES
UP-FLO = DOWN-FLO — HORIZONTAL
13,000 to 102,400 Btuh Electric Heating Capacity
Add -On Cooling — 1-1/2 thru 5 Nominal Tons
1 �tti•rar•r.
:i J .•
i'
ES12 MODEL — DOWN-FLO
WITH FIELD INSTALLED CPR12 COIL
. ®
ES12 MODEL — HORIZONTAL
WITH FIELD INSTALLED CPS12 COIL
i
ENGINEERING DATA
HEATING UNITS
ELECTRIC
Page 11
July 1, 1983
Supersedes 9-1-82
M1
Ni a�
14 �1
t �
i;, •i
E112 MODEL — UP-FLO
WITH FIELD INSTALLED CP12 COIL
Multi -Position Line Of Electric Furnaces Provide High Efficiency Performance And Installation Flexibility
The Lennox E12 and ES12 electric furnaces are designed for multi -position
installation in a basement, utility room, alcove, closet, crawlspace or
attic. Versatile units are applicable to heating only, heating -cooling or heat
pump applications. Several models are available in varying sizes with a wide
range of heating and cooling capacities. E12Q2 and E12Q3 models are for
up-flo applications only. The E112124 and E1205 series models are applicable
to either up-flo or down-flo installation. The ES12Q2, ES1203 and ES12Q4
series can be installed in the horizontal or down-flo position and the ES12Q5
models in the horizontal only.
The optional field additive "slide -in" coil installs internal to the cabinet. (up
stream from the blower and electric heat elements) and is specially
matched to the unit for efficient air delivery and maximum capacity. For
up-flo applications optional return air cabinets are available for installation
on either side of the unit.
The cabinets are trim and attractive appearing with a durable electro -bonded
paint finish. Removable front panels provide complete service access to
cabinet interior. Variable speed direct drive blowers have sufficient capacity
to handle cooling air volume requirements. Hammock style fiberglass air
filters are furnished on E12 up-flo models only. Nichrome heating elements
give long service fife and efficient heating operation. Factory installed cir-
cuit breakers are accessible external to the cabinet. Optional accessories
available include thermostat, return air cabinets, down-flo additive base,
outdoor thermostat and filter kits.
Units have been tested and rated according to Department of Energy (DOE)
test procedurbs and Federal Trade Commission (FTC) labeling regulations
in the Lennox Research Laboratory. Furnaces are U.L. listed. In addition,
units and components within are bonded for grounding to meet safety
standards for servicing required by UL and NEC. Blower performance data
is from unit tests conducted in the Lennox Laboratory air test chamber.
Each unit is test operated at the factory and shipped assembled (except
for the DX coil) with all controls mounted and prewired. The installer has
only to make the necessary field duct and electrical connections.
Typical Applications
Down -Flo Installation
Horizontal Installation
With Electronic Air Cleaner
And Humidifier
NOTE — Specifications, Ratings and Dimensions subject to change without notice.
Up -Flo Installation
With Return Air Cabinet
ES12Q5
HORIZONTAL MODELS
121-518 314 I 33�
1-118 i � ELECTRICAL INLETS
3-118 4-518
-10 J13-7/8-10-
41111
20-314 FLOW
SUPPLY
AIR
OPENING
1-
23
11
1_1184TERMINAL STRIP 1-118
(Low Voltage)
OUTLET END FRONT VIEW INLET END
CH16-51FF
HORIZONTAL COIL
3/4r-12�3/4 34
2
I
AIR 2
FLOW
NOTE — Air flow right to left as shown. 9 LIQUID LINE
Do not reverse.
9 5/8�{ SUCTION
1 LINE
—Q 10-1/4
I I 4
2
25
MAIN _L \AUXILIARY 2
DRAIN 2-7/8 5 DRAIN
CH16-65V
HORIZONTAL COIL
42-1/2 10 21-1/4 3/4
11-7/16 19-5/8 11-7/16 AIR
23 LIQUID LINE 3
21 SUPPLY
AIR 1/2t
VAPOR FLOW
4
OPENING / UNE
41/4 ®_
1" 7/8 CONDENSATE
118
2-9/16
��j
io 35-7/8 w
17-7/8 RETURN
AIR
OPENING
2-9/16
2-1/4 DRAINS
OUTLET SIDE 41/4 INLET SIDE
NOTE — Air flow right to left as shown.
Do not reverse.
FRONT VIEW
ES12Q5 UNIT WITH
CH16-51FF COIL
*Transition must have a 61/2 inch straight
.action from coil before'transitioning.
ES12Q5 UNIT WITH
CH16-65V COIL
4
BLOWER
WIIELECTRC7
I
ELEMENTS
1-
23
11
1_1184TERMINAL STRIP 1-118
(Low Voltage)
OUTLET END FRONT VIEW INLET END
CH16-51FF
HORIZONTAL COIL
3/4r-12�3/4 34
2
I
AIR 2
FLOW
NOTE — Air flow right to left as shown. 9 LIQUID LINE
Do not reverse.
9 5/8�{ SUCTION
1 LINE
—Q 10-1/4
I I 4
2
25
MAIN _L \AUXILIARY 2
DRAIN 2-7/8 5 DRAIN
CH16-65V
HORIZONTAL COIL
42-1/2 10 21-1/4 3/4
11-7/16 19-5/8 11-7/16 AIR
23 LIQUID LINE 3
21 SUPPLY
AIR 1/2t
VAPOR FLOW
4
OPENING / UNE
41/4 ®_
1" 7/8 CONDENSATE
118
2-9/16
��j
io 35-7/8 w
17-7/8 RETURN
AIR
OPENING
2-9/16
2-1/4 DRAINS
OUTLET SIDE 41/4 INLET SIDE
NOTE — Air flow right to left as shown.
Do not reverse.
FRONT VIEW
ES12Q5 UNIT WITH
CH16-51FF COIL
*Transition must have a 61/2 inch straight
.action from coil before'transitioning.
ES12Q5 UNIT WITH
CH16-65V COIL
C
E12 SERIES SPECIFICATIONS
Model No.
E12Q2-05
E12Q2-10
E12Q2-15
E12Q3-05
E12Q3-10
E12Q3-15
E12Q3-20
E12Q4-10
E12Q4-15
E12Q4-20
E12124-25
E12Q5-15
E120,5-20
E12Q5-25
E12Q5-30
Blower wheel nominal diam. x width (in.)
9 x 7
10 x 8
10 x 8
12 x 12
Blower motor hp
1/4
1/3
1/2
3/4
Up -Flo
Models Only
lNet free filter area (sq. ft.)
5.3
6.3
7.8
8.7
I Filter cut size (in.) 30 x 26 x 1 40 x 26 x 1 44 x 26 x 1
50 x 26 x 1
Tons of cooling that can be added
1-1/2 or 3
2-1/2 or 3
3, 3-1/2 or 4
4 or 5
Shipping weight (lbs.)
121
127
160
192
Number of packages in shipment
1
1
1
1
Electrical characteristics
E12Q5-20
208-240v/60hz/1 phase
100%
tOptional Return Air
Cabinet (Up -Flo only)
Model No.
100%
RA10-16-49
RA10-16-53
100%
Shipping weight (lbs.) 54 56
LB-51349CA
tOptional Additive Coils
Model No.
Up -Flo
CP12-26V
CP12-31V, CP12-41V
CP12.46V, CP12-51V
CP12-65V
Down -Flo ---- ---- CPR12-46V, CPR12-51V
CPR12-65V
tDown-Flo Additive Base (Optional)
----
----
LB-34695BC
LB-34695BD
tFilter Kit (Optional) Down -Flo Models Only
----
----
•LB-51349CA
tMust be ordered extra.
•2 kits are required for down-flo applications.
E12 SERIES ELECTRIC HEAT RATINGS
Model Number
tOutput Btuh
IA. F.U.E.
E12Q2-05
16,000
100%
E1202-10
31,000
100%
E12Q2-15
45,000
100%
E12Q3-05
16,000
100%
E12Q3-10
31,000
100%
E1203-15 1
46.000
100%
E12Q3-20
61,000
100%
E12Q4-10
31,000
100%
E12Q4-15
46,000
100%
E1204-20
61,000
100%
E12Q4-25
75.000
100%
E1205-15
46,000
100%
E12Q5-20
62,000
100%
E12Q5-25
75,000
100%
E12Q5 30
91,000
100%
tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to
FTC labeling regulations.
ES12 SERIES SPECIFICATIONS
Model No.
ES12Q2-05
ES12Q2-10
ES12Q2-15
ES12Q3-05
ES12Q3-90
ES12Q3-15
ES12Q3-20
ES12Q4.05
ES12Q4-10
ES12Q4-15
ES12Q4-20
ES12Q5-15
ES12Q5-20
Blower wheel nominal diam. x width (in.)
9 x 7
9 x 7
10 x 8
12 x 9
Blower motor hp
1/4
1/3
1/3
3/4
Tons of cooling that can be added
1-1/2 or 3
2-1/2
3 or 3-1/2
4 or 5
Shipping weight (lbs.)
121
131
140
116
Number of packages in shipment
1
1
1
1
Electrical characteristics
46,000
208-240v/60hz/1 phase
ES1204-20
tOptional Additive Coils
Model No.
Horizontal
CPS12-26V
CPS12-31VCPS12-41/46V
99.3%
CH16-51FF or CH16-65V
Down -Flo CPR12-26V CPR12-31V CPR12-41V
----
tDown-Flo Additive Base (Optional)
LB-34695BA
I LB -3469588
I LB-34695BB
tFilter Kit (Optional)
LB-51349CA
---
tMust be ordered extra.
ES12 SERIES ELECTRIC HEAT RATINGS
Model Number
tOutput Stuh
tA.F.U.E.
ES12122-05
15,000
98.8%
ES12Q2-10
30,000
98.8%
ES12Q2-15
47,000
98.8%
ES1203-05
16,000
99.0%
ES12Q3-10
31,000
99.0%
ES 12Q3-15
45,000
99.0%
ES12Q3-20
63,000
99.0%
ES12Q4-05
16,000
99.0%
ES12Q4-10
31,000
99.0%
ES12Q4-15
46,000
99.0%
ES1204-20
64,000
99.0%
ES12Q5-15
46,000
99.3%
ES1205-20
65,000
99.3%
tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to
FTC labeling regulations.
—13—
Lyffff9ke
l
HP16 SERIES
HEAT PUMP OUTDOOR UNITS
*18,700 to 56,000 Btuh Cooling Capacity
*19,900 to. 61,000 Btuh Heating Capacity
*ARI Standard 240 Certifed Ratings
���nE♦ .<fw.
QAt1fJT1011 URLE OILY �.
[p�
WMEM IILED EERII HIORII �OM[MT511f lalFD � -
e '
s,.enac ,o„ nim:.
Reliability, Economy and Outstanding Efficiency for Year
Round Operation are Featured in Line Of HP16 Series Heat Pumps
The Lennox HP16 series heat pump outdoor units consist of seven models
ranging from 1-1 /2 thru 5 tons. This family of energy efficient outdoor units
have SEER'S of up to 9.8 with a cooling capacity range of 18,700 to 56,000
Btuh and COP ratings of up to 3.1 with heating capacities of 19,900 to 61,000
Btuh. A variety of matching up-flo, down-flo and horizontal blower powered
indoor units, with optional supplemental electric heat, provide selective sizing
J
nd installation versatility. For complete data on indoor units see individual
ulletins. Several refrigerant line sets are available in various lengths, see
line kit table for selection. Line sets are optional and must be ordered extra.
The HP16 cabinet is heavy gauge galvanized steel with a durable baked -on
enamel paint finish. Special paint process protects cabinet against all kinds
) of weather. Design of cabinet with louvered inlet air panels and horizontal
l air discharge protects fan, fan motor, compressor and other internal com-
- inents from the weather. Heavy duty base support channels elevate unit
doove mounting surface. Dual outdoor coils provide extra large surface area
for highest heat transfer. Coils are protected by rugged steel guards.
Automatic defrost control system operates only when required. Compressor
crankcase heater and heating -cooling thermostat with emergency heat sub-
base and warning lights are furnished as standard.
Outdoor units are test operated at the factory to insure proper operation
and are shipped ready for installation. Installer has only to locate unit and
make refrigerant line and electrical connections to complete installation.
TF — Snaeifiratiaae Ratinne and nimpncinns suhiect to chance without notice.
�. I ENGINEERING DATA
HEAT PUMPS
MATCHED REMOTE
SYSTEMS
Page 11
July 1, 1983
Supersedes 9-1-82
Typical Applications
l�
r
SELECTOR
Lennox
Outdoor Unit
Model No.
*ARI Std.
270 SRN (bels)
tARI Standard 240 Ratings
t
a u
CO
Z m
m V
Btuh
C
Lennox Indoor Unit Used
Cool.
Cap.
Stuh
High
Temp.
Htg.
Cap.
Low
emp.
Htg.
Cap.
Btuh
Total Unit Watts
Up -Flo
Down -Flo
Horizontal
Cooling
SEER
Btuh/
Watt
1 Phase
EER
Btu/
Watt
3 Phase
High
Temp.
Htg.
HSPF
C.O.P.
Low
Temp.
Htg.
C.O.P.
CPR12-26V
18,700
20,600
11,000
2140
9.30
---
2030
7.20
2.95
1604
2.00
31%
ICP12-26V
---
HP16-211V
/E7202
/ES12Q2
(7.6)
CPS12-26V
19,100
19,900
11,000
2140
9.40
--
1955
7.20
3.00
1585
2.00
26%
-
- -
/ES12Q2
CP12-26V
CPR12-26V
22,600
25,000
14,000
2630
9.00
---
2525
7.40
2.90
2060
2.00
24%
-
-
/E12Q2
/ES12Q2
H P16-261 V
CPS 12-26V
23,400
25,600
14,500
2650
9.30
----
2475
7.30
3.00
2095
2.05
25%
----
---
(7.81
/ES12Q2
-31V
CPR12-31V
24,400
26,000
14,000
2723
9.60
----
2478
7.50
3.10
2004
2.05
18%
ICP12
----
/E1203
/ES1203
CP12-31 V
28,800
32,000
18,100
3400
9.10
----
3139
7.40
3.00
2599
2.05
22%
/E12Q3
CP812-31V
CPS12-31V
29,000
31,800
17,800
3380
9.10
----
3119
7.40
3.00
2579
2.05
22%
----
HP16-311V
/ES1203
/ES1203
(8.0)
CP12-41V
30,200
32,200
18,200
3410
9.25
---
3035
7.50
3.10
2650
2.10
22%
----
----
/E12Q3
CPR12-41V
30,200
32,200
18,100
3445
9.10
----
3070
7.50
3.05
2549
2.05
22%
----
---
----
/ES12Q4
/ES12Q4
CPR12-41V
/ES12Q4
CPS12-41/46V
35,200
35,800
19,600
4115
9.10
8.60
3636
7.55
2.90
2928
1.95
23%HP16-411V
CPR12-46V
/ES12Q4
(Use SEER)
/E12Q4
HP16-413V
35,200
35,800
19,600
4053
9.30
8.70
3584
7.55
2.95
2875
2.00
23%
CP12-41V
/E12Q3
---
-
(Use EER)
(8.2)•
CP12-46V
35,000
36,000
19,800
4140
9.00
8.50
3661
7.60
2.90
2953
1.95
23%
-
-
-
/E1204
42,000
38,000
21,000
4.347
9.00
8.85
4250
6.70
2.60
3180
1.95
21%
----
----
•CH 16-51 FF
HP16-461 V
(Use SEER) ,CPR12-46V
-
41,500
42,500
26,000
5048
8.70
8.20
4488
7.60
2.75
3696
2.05
24% �
-
CPS12-41/46V
HP16-413V
/E1204
/ES12Q4
(Use EER)
(8.2) >j
41,500
42,500
26,200
5093
8.70
8.10
4533
7.60
2.75
3741
2.05
24%
CP12-46V
----
-
/E1ZQ4
H P16-511 V ;
46, 500
49,500
29,500
5570
9.00
8.35
4363
8.05
3.00
3835
2.30
22%
-
-
•CH 16-51 FF
(Use SEER)
CPR12-51V
HP16-513V
45,500
50,000
30,200
5614
8.80
8.10
4939
7.85
2.95
3988
2.20
20%
ICP12-51V
-
(Use EER)
I
/E12Q4
/E1204
46,500
49,500
29,800
5570
9.00
8.30
4872
8.05
3.00
3844
2.30
20%
----
--
CH16-65V
(8.2) `'
H P16-651 V
(Use SEER►
55,500
59,500
34,400
6789
8.15
8.20
6005
7.40
2.90
4715
2.15
22%
- -
--
CH 16-65V
55,500
62,500
1
37,600
7177
8.05
7.75
6340
7.50
2.90
5032
2.20
23%
CP12 65V
CPR12 65V
-
HP16-653V
(Use EER)
18.2)
/E12Q5
/E1205
*Sound Rating Number in accordance with ARI Standard 270.
tRated in accordance with ARI Standard 240 and DOE; At 450 cfm (maximum) indoor air volume per ton of cooling capacity.
Cooling Ratings - 950F outdoor air temperature and 800F db/670F wb entering indoor coil air.
High Temperature Heating Ratings - 47OF db/430F wb outdoor air temperature and 700F db entering indoor coil air.
Low Temperature Heating Ratings - 1701' db/15°F wb outdoor air temperature and 700F db entering indoor coil air.
'Heating Seasonal Performance Factor.
-Requires field installed check and Expansion Valve Kit (LB-34792BD). Must be ordered extra.
-13-
RATINGS
NOTE - To determine Sensible Capacity, Leaving Wet Bulb and Dry Bulb temperatures not shown
in the cooling table see Miscellaneous Engineering Data section, Page 9.
HP16-651VMV COOLING CAPACITY WITH CP12-65V OR CPR12-65V INDOOR COIL UNIT
Enter.
Wet
Bulb
(°F)
Total
Air
Vol.
(cfm)
-
Outdoor Air Temperature Entering Outdoor Coil (°F)
85
95
105
115
Total Comp.
Cool Motor
Cap. Watts
(Btuh) Input
Sensible
To Total
Ratio ISM
Total
Cool
Cap
(Btuh)
Comp.
Motor
Waw
Input
p
Sensible
To Total
Ratio (S/T)
D Bulb I FI
76 80 84
Total
Cool
Cap.
(Btuh)
Sensible
Comp.
Motor To Total
Watts Ratio IS/T)
Input-7-6-r-80--rDry Bulb I Fl
84
Total
Cool
Cap.
Igtuhl
Sensible
Comp.
Motor To Total
Watts Ratio IS/T)
FI
Input Dry Bulb (OF)
76 1 80 1 84
Dry Bulb I
76 80 B4
Air Volume
2000
68,400 5060
1 .80 .92 1.00 1155,600
Motor
5380
.82 .95 1.00
52,900
5680 .84 .98 1.00
50,100
5950 .87 1.00 1.00
63
2250
59,600 ` 5110
.83 .97 1.00
56,800
5440
.85 .99 1.00
54,000
5750 .88 1.00 1.00
51,800
6050 .91 1.00 1.00
15
2500
60,600 5170
.87 1.00 1.00
58,000
5510
.89 1.00 1.00
55,500
5830 .92 1.00 1.00
53,000
6130 .95 1.00 1.00
76,200
2000
62,200 5240
.62 .74 .86
59,200
5560
.63 .76 .88
56,200
5870 .65 .78 .91
53,300
6140 .66 .80 .94
67
2250
63,200 5280
.64 .77 .90
60,100
5610
.66 .80 .93
57,000
5910 .67 .82 .96
54,100
6190 .69 .84 .99
3720
2500
64,100 5320
.67 .81 .94
60,900
5650
.68 .83 .97
57,800
5950 .70 .85 1.00
54,800
6230 .72 .88 1.00
2000
66,600 5430
.46 .58 .69
63,400
5760
.47 .59 .71
60,200
6080 .47 .60 .72
57,200
6360' .48 .61 .74
71
225^
67,500 5470
.47 .60 .72
64 200
5800
.48 .61 .74
61,000
6120 .49 .62 .76
57,900
6390 .49 .64 .78
2500
68,300 5500
.48 .62 .75
64,900
5840
.49 .63 .77
61,700
6150 .50 .65 .79
58,500
6430 .51 .66 .82
NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction.
HP16-651V-653V HEAT PUMP OUTDOOR UNIT HEATING CAPACITY
NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur.
HP16-651V-653V HEATING PERFORMANCE
at 2250 cfm Indoor Coil Air Volume
(CP12-65V Et CPR12-65V)
*Outdoor
Temperature
(Degree F)
Compressor
Motor Watts
Input
Air Temperature Entering Outdoor Coil (°F)
65
1 45 25
5 -15
Indoor
Indoor Coil
Total
Comp.
Total
Comp. Total
Comp.
Total
Comp. Total
Comp.
Unit
Air Volume
Model
(cfm)
Heating
Motor
Heating
Motor Heating
Motor
Heating
Motor Heating
Motor
No.
70F db
Capacity
Watts
Capacity
Watts Capacity
Watts
Capacity
Watts Capacity
Watts
36,800
15
(Btuh)
Input
(Btuh)
Input (Btuh)
Input
(Btuh)
Input (Btuh)
Input
CP12 65V
C00112 -65V
2000
76,200
5615
59,400
4745 41,800
3830
29,800
3175 18,700
2835
2250
77,200
5490
1 60,100
4670 42,300
3770
30,200
3155 19,000
1 2815
250078
100
5385
60 800
4610 42,800
3720
30,500
3135 19,200
2795
NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur.
HP16-651V-653V HEATING PERFORMANCE
at 2250 cfm Indoor Coil Air Volume
(CP12-65V Et CPR12-65V)
*Outdoor
Temperature
(Degree F)
Compressor
Motor Watts
Input
Total
Output
(Btuh)
65
5490
77,200
60
5290
73,100
55
1 5095
69,000
50
4885
64,500
47
4760
62,000
45
4670
60,100
40
4450
55,700
35
4215
51,000
30
3975
_ 46,500
25
3770
42,300
20
3560
38,700
17
3510
36,800
15
3330
35,300
10
3265
32,800
5
3155
30,200
0
3070
27,700
-5
3005
25,100
-10
2915
22,300
-15
2815
19,000
-20
2710
16,200
*Outdoor temperature at 70% relative humidity. Indoor temperature at 700.
-14p-
0
EHB-Sw
a
SPECIFICATIONS
Model'No.
HP16-211V
HP16-261x/
HP16-311V
HP16-411V
HP16-413V
HP16-461V
HP16-463V
HP16-511V
HP16-513V
HP16-651V
HP16-653V
Outdoor
Coil
Net face area (sq. ft.)
6.67
6.67
8.00
10.11
10.11
12.9
12.9
Tube diam. (in.) 3/8 3/8 3/8 3/8 3/8 3/8
3/8
No. of rows 3 3 3 3 3 3
4
Fins per inch 15 15 15 15 15 15
15
Outdoor
Fan -
Diameter (in.)
18
20
20
22
24
24
24
No. of blades 4 4 4 4 4 4
4
Motor hp 1/10 1/5 1/5 1/4 1/3 1/3
1/3
-Cfm (factory setting) 1750 2400 2900 3100 3800 3600
3800
'Minimum circuit ampacity 11
Rpm (factory setting)
1085
1115
1040
830
830
840
810
Watts (factory setting) 135 205 305 285 395 370
425
Refrigerant -22 (charge furnished)
7 lbs. 14 oz.
8 lbs. 7 oz.
9 lbs. 4 oz.
11 lbs. 0 oz.
12 lbs. 4 oz.
14 lbs. 4 oz.
19 lbs. 8 oz.
Liquid line connection (sweat)
3/8
3/8
3/8
3/8
3/8
3/8
1/2
Vapor line connection (sweat)
5/8
5/8
3/4
3/4
7/8
7/8
1-1/8
Shipping weight (lbs.)
245
250
275
322
333
403
411
Number of packages
1
1
1
1
1
1
1
ELECTRICAL DATA
Model Number
HP16-211V
HP16-261V
HP16-311V
HP16-411V
HP16413V
Line voltage data
208/230V
60hz/lph.
208/230V
60hz/lph.
208/230V
60hz/lph.
208/230V
60hz/lph.
208/230V
60hz/3ph
Compressor
Rated load amps
9.7.
11.5
14.7
17.9
12.5
Power factor 1 .95 .96 .95 .94
.89
Locked rotor amps 48.0 54.0 65.0 83.5
66.0
Outdoor Coil
Fan Motor
Full load amps
0.70
1.3
1.5
2.0
2.0
Locked rotor amps 1.0 3.5 3.5 4.0
4.0
Rec.maximum fuse or circuit breaker size (amps)
20
25
30
40
30
'Minimum circuit ampacity 11
12.8
15.7
19.8
24.4
17.6
'Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
ELECTRICAL DATA
Model Number
HP16-461V
HP16463V
HP16-511V
HP16-513V
HP16-651V
HP16-653V
Line voltage data
208/230V
60hz/1ph.
208/230V
60hz/3ph
208/230V
60hz/1ph
208/230V
60hz/3ph
208/230V
60hz/lph
208/230V
60hz/3ph
Compressor
Rated load amps
21.5
13.7
25.6
15.9
28.0
19.0
Power factor 1 .96 .88 .96 .90 .97
1 .90
`- HEATER UNIT-
Locked rotor amps
95.4
82.0
116.0
92.0
142.0
107.0
Outdoor Coil
Fan Motor
Full load amps
2.5
2.5
2.5
2.5
2.5
'2.5
Locked rotor amps 5.5 5.5 5.5 5.5 5.5
5.5
Rec.maximum fuse or circuit breaker size (amps)
50
30
60
35
60
45
'Minimum circuit ampacity
29.4
19.6
34.5
22.4
37.5
26.3
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
FIELD WIRING
-------,
LENNOX rDISCONNECT'
THERMOSTAT SWITCH i
.-------� B ------------+
IDISCONNECTI I LENNOX I
I SWITCH OPTIONAL I
A - Two or Three wire power (see Electrical Table)
(furnished)
$ (BY OTHERS) :
j (BY OTHERS), r AUXILIARY
B - Two or Three wire power (size to heater capacity)
___J
a -_-____-J r ELECTRIC I
`- HEATER UNIT-
C - Two wire power (size to indoor coil blower motor)
E
A
I OPTIONAL
I OUTDOOR
'THERMOSTAT
j
D - Two wire low voltage (18 ga. minimum)
I F
E - Eight wire low voltage (18 minimum) with Electric Heat
ga.
- Ten wire low voltage with Optional Outdoor Thermostat
r
WISCONNECTI C
F - Four wire low voltage (18 a. minimum)
9 g
OUTDOOR
UNIT
r SWITCH
(BY OTHERS)
G - Three Wire low voltage (18 ga. minimum)
I
LENNOX
INDOOR UNIT
-Fie/d wiring not furnished -
NOTE - All wrong to conform to NEC and local electrical codes.