Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-2544 (RC)
t P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4ht " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT r ( Application Number 06-000025 Property Address: 7 4 8080 CALLE ESTADO STE 101 APN: 770-151-003- - - Application description: REMODEL - COMMERCIAL Property Zoning: VILLAGE COMMERCIAL Application valuation: 250000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B, C7 License No.: 761009 \Date: '49_01 Contractor: S OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.: ' 1 _ 1 I, as owner of the property, or my employees. with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPER 11T Owner: MARVIN WELLS L 78080 CALLE ESTADO LA QUINTA, CA 92253 Contractor: SAN DIEGO OFFICE I 4863 SHAWLINE ST, SAN DIEGO, CA 9211 (858)495-7364 LiC. No.: 761009 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIQNS (760) 777-7153 Date: 8/07/06 STE 201 -=---------------------------7----------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 046-0014739 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section ��13770�0 of the Labor Code, I shall forthwith comply with those provisions. `'ate: "06► Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE.HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDEDTOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT _ IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to upon the above-mentioned property for inspection purposes. Date:9-9-016%.ignature (Applicant or Agent): Application Number . . . . 06-00002544 ------ Structure Information EXISTING SHELL (OLD LIBRARY) ----- Other struct info CODE EDITION O1BMP04E05EN FIRE SPRINKLERS YES MIXED-USE OCCUPANCY M/B r OCCUPANT LOAD 88.00 1ST FLOOR SQUARE FOOTAGE 3442.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 1164.50 Plan Check Fee 756.93 Issue Date Valuation . . . . 250000 Expiration Date 2/03/07 Qty Unit Charge Per Extension BASE FEE 639.50 150.00 3.5000 THOU BLDG 100,001-500,000 525.00 ---------------------------------------------------------------------------- Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 83.84 Plan Check Fee 20.96 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/03/07 Qty Unit Charge Per Extension BASE FEE 15.00 3442.00 ,.0200 ELEC GARAGE OR NON-RESIDENTIAL 68.84 --------------------------------------- ------------------------------------ Permit MECHANICAL Additional desc . Permit.Fee . . . . 63.50 Plan Check Fee 12.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/03/07 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 4.5000 EA MECH VENT INST/ DUCT ALT 22.50 2.00 6.5000 EA MECH VENT FAN 13.00 2.00 6.5000 EA MECH OTHER MECH EQUIPMENT 13.00 ---------------------------------------------------------------------------- Permit PLUMBING Additional desc.. . Permit Fee . . . . 76.50 Issue Date . . . . LQPER IIT Plan Check Fee . . 19.13 Valuation . . 0 'A LQPERMIT Application Number . . . . . 06-00002544 Permit . . . . . . PLUMBING Expiration Date . . 2/03/07 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 -------------------------=-------------------------------------------------- Special Notes and Comments BANK TENANT IMPROVEMENT. 3442 SQ.FT. M/B OCCUPANCY, TYPE V -N CONSTRUCTION. . 88 OCCUPANTS.[PACIFIC WESTERN BANK] 2001 CBC,CMC,CPC, 2004 CEC, 2005 ENERGY CODES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 75.70 ENERGY REVIEW FEE 75.70 v Fee summary Charged Permit Fee Total 1388.34 Plan Check Total 809.65 Other Fee Total 151.40 Grand Total 2349.39 Paid Credited Due .00 .00• 1388.34 .00 .00 809.65 .00 .00 151.40 .00 .00 2349.39 1 Building -78-080 7 - O Q O Address V C� Owner Mailing Address City IS44 t7,Er4o State Lic. & Classif. 7!0 l 0 0 Arch., Engr., Designer � f 1) , d- jV I P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO ('AmE E S r4 DO LA QUINTA, CALIFORNIA 92253 ' PA, 11140 0-9:90. BUILDING: TYPE CONST. OCC.. GRP. lo, L6 A.P. Number 770 6 S 00 3 p ITO. Legal Description ,..►E sT -1 A 5 sVAA..J L, 10 City Lic. # LICENSED CONTRACTOR'S DECLARATION 1 rFnJ I cen d under provisions of Chapter 9 (commencing with Section 70f a Busin ss and Professions Code, and my license is in full force and eIf i SI AT DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ori mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's compensation Insurance, or certified co thereof. Sec. 3800, a or Code. Policy No. bey i 39O Company �►'r <f u ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection proses. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Project Description 7-i=%}AjJ-r- ►>-,.cAjT -Diur •w pair/- o..J L. y . 1LOCg S,C �u.TG . Liti, ys� Sq. Ft. No. Size 3,yy2- Stories No. Dw. Units New ❑ Add ❑ Alter Repair ❑ Demolition ❑ IS6.1 - S.0cTagW7a �S `��-Es� $58-y►�-305 Estimated Valuation Zsp�od PERMIT AMO T Plan Chk. Dep. AID �, 4 Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Certificate of Occupancy V � T4hf ��IGf�IN - ItcowoanhnG� . G� OF Building Y p & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time- of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City, regulating building construction and/or use. BUILDING ADDRESS: 78-080 CALLE ESTADO STE 101 Use classification: BANK (WESTERN PACIFIC BANK) Building Permit No.: 06-2544 Occupancy Group: M/B Type of Construction: V-N Land Use Zone: VC Owner of Building: MARVIN WELLS Address: 78-080 CALLE ESTADO #201 City, ST, ZIP: LA QUINTA, CA 92253 By: STEVE TRAXEL Date: 09-28-2006 Building-Official POST IN A CONSPICUOUS PLACE LLJJ Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning . Beaumont Calimesa Canyon Lake Coachella Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT 210 West San Jacinto Avenue • Perris, California 92570 • (951) 940-6900 • Fax (951) 940-6910 Date 2bl Building Department ReLAO AO Dto -U 01 O The Riverside County Fire Department is granting the Fire clearance for the following Location -1 �Q $O ��a�} l.A; Optm-�A, G•4 Please call if you should have questions 760-863-8886 Respectfully, '��' Fire System ector VON DUPRIN® 22 Rim Exit Device 22 rim exit device for all types of single and double doors with mullion, UL listed for Panic Exit Hardware. Devices are ANSI A156.3, 2001, Grade 1. Covers stock hollow metal doors with 161* cutouts. Fits door stiles as narrow as 3 13/1x" (97mm), see page 12. See opposite page for available C outside trim and device functions. *Not applicable with all strike and mullion combinations, consult factory. Specifications 299 Strike --- ----------------------------..._��— Device Functions Ships ready for all functions; EO, DT, NL, TP, K, L Device Handing Non -Handed CITY OF LA QUINT Device Lengths 3' (914mm) — see minimum door opening chart at bottom of page BUILDING & SAFETY DEPT. 4' (1219mm) — see minimum door opening chart at bottom of page APPROVED Finishes SP28, SP313 FOR CONSTRUCTION Strikes 299 Dull Black Optional Strikes see page 12 !� Dogging Feature Hex key dogging standard DA 0� �/ LD Less Dogging see page 14 • Electric Options LX Latchbolt Monitor Switch see page 14 RX Touch Bar Monitor Switch see page 14 RX2 Double Touch Bar Monitor Switch see page 14 ALK Alarm Exit Kit see page 14 Miscellaneous Options GBK Glass Bead Kit see page 15 Fasteners & Includes 1 3/4 (19mm) — 21/4 (57mm) Wood & Metal Doors Sex Bolts (SNB) Optional SNB available for device, see next page for quantities Latch Bolt Deadlocking, 3/4 (19mm) throw_ Device Centerline from 3913/16" (1011mm) at center of device Finished Floor3911/16" (1008mm) with Mullion Device Dimensions see page 13 See page 16 for How to Order specification Minimum Door Opening Chart Stop Single Double Door Minimum Door Opening Minimum Door Opening Height Strike Door w/Mullion for 3" device* w/ALK* 1/2"" 299 Yes — 26.500'- (673mm) 33.250"(845mm) 1/2"" 1439 Yes - 25.687-' (652mm) 32.437"(824mm) 1/2"" 299 — 4754/4854/4954 27.000" (686mm) 33.750'"(857mm) 1/2"" 299 — 5654 25.812" (656mm) 32.562"(827mm) 1/2"" 1408 — 5754 25.750" (679mm) 32.500"(826mm) 1/2 1606 — 1654 26.562'" (675mm) 33.312"(846mm) 299 Yes — 26.750'- (679mm) 33.500"(851mm) 1439 Yes — 25.937" (659mm) 32.687"(830mm) 299 — 4754/4854/4954 27.125" (689mm) 33.875"(860mm) 5/6" 299 — 5654 26.687" (678mm) 33.437"(849mm) 5/6*' 1408 — 5754 25.875" (657mm) 32.625'-(829mm) 5/6" 1606 — 1654 26.687" (678mm) 33.437"(849mm) *For 4" device, add 6" (152mm) 2 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. r 78 D&0&t:>l�G� ,�,� 7&" A911102— 4�U a'pl VON DUPRIN® 22 Rim Exit Device Standard Trim ANSIBHMA A156.3 (2001) Grade 1 Trim Exit only Dummy Trim Night Latch Night Latch Key Locks & Unlocks Key Locks & Unlocks Pull when Dogged Key Retracts Latchbolt Key Retracts Latchbolt i Optional Pull Required 16 `ice 11 Product Description 22EO 22DT 22NL 22NL-OP Trim Description — 210DT* 210NL* 110NL-MD* Trim Description 230TP* 210K 230L* 110NL-WD* Escutcheon Plate Size — 53/a x 425/32 x 3/32' 5%' x 425/32 x 3/32" — (76x121x2mm) (76x162x24mm) (137x121x2mm) (137x121x2mm) — Pull Center to Center — — — — Projection — 131/32" (42mm) 131/32' (42mm) — ANSI Function 01 02 03 03 Cylinder Type — — Rim Rim Optional Trim (See page 10) 230EO 230DT 230NL — Optional #425 Sex Bolt 6 (with no trim) 2 2 Quantity for Device 2 (with EO trim) 2 2 6 ANSIBHMA A156.3 (2001) Grade 1 Trim . ANSI/BHMA A156.3 (2001) Grade 1 Trim Thumbpiece Knob Lever Key Locks & Unlocks Key Locks & Unlocks Key Locks & Unlocks i Product Description 22TP 22K 22L Trim Description 230TP* 210K 230L* Escutcheon Plate Size 3' x 121/,6 x %2" 3' x 425/32" x 3/32' 3" x 63/8" x 15/ir (76x306x2mm) (76x121x2mm) (76x162x24mm) Pull Center to Center 5'/z" (140mm) — — Projection 2" (51mm) 275/,6" (75mm) 2W (67mm) ANSI Function 05 08 08 Cylinder Type 11/4' Mortise Furnished 11/4' Mortise Optional Trim (See page 10) 230TP-BE 21OK-BE 230L -BE Optional #425 Sex Bolt Quantity for Device 2 2 2 . ANSI/BHMA A156.3 (2001) Grade 1 Trim SERIES Desiovs & Finishes JUPITER 605 Symbol: JUP 606 Material: Pressure cast 609 zinc lever; wrought brass 612 or bronze rose jo 613 Finishes: 605, 619 606, 612, 619, T 606,612,61 3-711V 625 4-1/4- ie 108 mm 613, 625, 626 87 mm Satin Chromium Plated 1 613 �� 1 F64 m t Matches D -Series Af-HE;V,S and L -Series 07 designs 605 626 626 2 NEPTUNE Symbol: NEP Material: Pressure cast zinc lever; wrought brass or bronze rose Finishes: 605,13 m N 414. 606, 612, 619, T 108 mm 613, 625, 626 87m 1 i 2.12y L 6 mm Matches D -Series SPAR.'1A and L -Series 17 designs SATURN Symbol: SAT Material: Pressure cast zinc lever; wrought brass or bronze rose Finishes: 605, 606, 609, 612, 613, ; mm T 4 619, 625, 626 T 1108 mm (15-37 1 87mm mmm 1 Marches t641mm D -Series RHODES and L -Series 06 designs OMEGA Symbol: OME Material: Pressure cast zinc lever; wrought brass or bronze rose Finishes: 605, 606, 609, 612, 613, - F T 619, 625, 626 13, m 4-114' T 108 mm 6-34116" 1 87 mm 1 Matches [2112.1 64 mm D -Series OML GA and I. -Series O,blfiGA designs 0 0 0 Finishes 605 Bright Brass 606 Satin Brass 609 Antique Brass 612 Satin Bronze 613 Oil Rubbed Bronze 619 Satin Nickel 625 Bright Chromium Plated 626 Satin Chromium Plated TACTILE WARNING (KNURLING) Symbol: 8SA Available Saturn design only. Outside lever is knurled unless otherwise specified. 41 This icon designates designs available with interchangeable core options. Specifications Handing: Non -handed. Door Thickness: 13/8" to 17/s" (35 mm to 48 mm) standard. 2" (51 mm) optional. Backset: 23/4" (70mnr) standard. 23/8' (60mm), 33/4" (95mm) and 5" (127mm) optional. Front: Steel. 21/4" x 11/s" square corner, beveled, for 23/a"backset standard. Optional 1" square corner, 1" radius corner, and non -UL drive-in / round face. For availability with specific backsets, see page 6. Lock Chassis: Steel, zinc dichromated for corrosion resistance. Latch Bolt: Brass, chrome placed, 1h" throw, deadlocking on keyed and exterior functions. Exposed Trim: Wrought brass and bronze. Levers are pressure cast zinc, plated to match finish symbols. Strike: ANSI curved lip strike 47/8" x l'/4" x 11/4" lip to center standard. Optional strikes, lip lengths and ANSI wrought strike box available. See page 7. Cylinder & Keys: 6 -pin patented Everest C123 keyway standard with two nickel silver keys per lock. Keying Options: Interchangeable core and Primus° high security cylinders. Master keying, grand master keying, and construction keying. Warranty: Three-year limited. Door Preparation SERIES Certificae icons ANSI Meets or excc_ecs Al 56.2 Series 4000, Grade 2 strength and oFerational requirements. Meets AI 17.1 Accessibility Code. Federal Meets FF -H-1 G6C. California Sate Reference Code (Formerly Tide 17, Califomia Starc Fire Marshal Standard) All levers wim. returns comply; levers return to wi:hin 1/2" of door face. UL / cUL: All locks listed _or A label single doors, 4' x 8'. Letter F and U__ symbol on latch front indicate listing. UL437 Listed ticking cylinder optional: specify Primus 20-500 -Series cylinder. CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG - 1-C I PROJECT NAME PACIFIC WESTERN BANK SIGNAI,%,,,,P,DATE DATE 06/27/06 PROJECT ADDRESS LA QUINTA Rodolfo Tapia _j LIGHTING MANDATORY MEASURES PRINCIPAL DESIGNER -LIGHTING Randy Minnier TELEPHONE 858-673-4445 Building Permit # DOCUMENTATION AUTHOR Rodolfo Tapia TELEPHONE 858-673-4445 Checked by/Date Enforcement Agency Use GENERAL INFORMATION Portable Lighitng Worksheet .0 ❑ DATE OF PLANS 06/27/06 BUILDING CONDITION FLOOR AREA 4,120 CLIMATE ZONE BUILDING TYPE ❑ NONRESIDENTI/ ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ❑ CONDITIONED SPACES ❑ UNCONDITIONAL SPACES ❑ INDOOR/ OUTDOOR SIGNS ❑ PHASE OF CONSTRUCTION ❑ NEW ❑ ADDITON ❑ ALTERATION METHOD OF COMPLIANCE Common Lighting Systems Method Worksheet pA ❑ PERFORMANCE ❑ COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ COMMON LIGHITNG STATEMENT OF COMPLIANCE Signs See OLTG-4-C Sign Worksheet in Chapter 6, Outdoor Lighting and Signs Chapter) This Certificate of Compliance lists the building features and erformance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code Regulations This certific to app/ only to ilding lighting regulations. The documentation reparer herebycertifies that the men s accurate and complete. DOCUMENTATION AUTHOR SIGNAI,%,,,,P,DATE 6/30/2006 Rodolfo Tapia _j LIGHTING MANDATORY MEASURES Cetificate of Compliance. Part 3 of 4 submittal is required onlo Cr i s 1 ' 06/27/06 The Principal Lighting Designer hereby certifies that the proposed4Wiing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in the application parts of Sections 110, 119, 130 through 132, 146, and 149 of Title 24, Part 6. ❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a-3) ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please check one: (These sections of the Buisness and Professions Code are printed in full in the Nonresidential Manual.) Q I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed by the State of California as a civil engineer or electrical engineer or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the perso 'b its preparation; and that I am a licensed contractor performing this work ❑ 1 affirm that I am eligible unde Division 3 th Business and Professions Code to sign this document because it permits to a structure or type of work descri d as a pt ursuant to Business and Professions Code Sections 5537,5538,6737.1 PRINCIPAL LIGHTING DESIGNER -NAME Randy Minnier IS!a/ 6/30/2006 LIC. # LIC. #5703 _j LIGHTING MANDATORY MEASURES ❑ Indicate location on plans of Note Block for Mandatory Measure LIGHTING COMPLAINCE FORMS & WORKSHEETS (check box if worksheet is included) R LTG -1-C, Parts 1 of 4 and 2 of 4 Cetificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals LTG -1-C, Part 3 of 4 Cetificate of Compliance. Part 3 of 4 submittal is required onlo Cr i s 1 ' LTG -1-C, Part 4 of 4 Certificate of Compliance. Part 4 of 4 submittal ' ed h - r 6d. ID LTG -2-C Interior Lighting Schedule %F El LTG -3-C Portable Lighitng Worksheet .0 ❑ LTG -4-C Lighting Controls Credit Worksheet GTS El LTG -5-C Interior Lighting Power Allowance GQ E) LTG -6-C Tailored Method Worksheet ❑ LTG -7-C Room Cavity Ratio Worksheet LTG -8-C Common Lighting Systems Method Worksheet pA LTG -9-C Line Voltage track Lighting Worksheet OLTG-4-C Signs See OLTG-4-C Sign Worksheet in Chapter 6, Outdoor Lighting and Signs Chapter) 2005 Nonresidential Compliance Form April 2005 7� �Qc) Ga&_ �s*c� p ,- 4 pFfa G 0 �*/ IL CERTIFICATE OF COMPLIANCE (Part 2of4) LTG PROJECT NAME PACIFIC WESTERN BANK DATE 06/27/06 INSTALLED INTERIOR LIGHTING FOR CONDITIONED AND UNCONDITIONED SPACES ALLOWED INTERIOR LIGHITNG POWER FOR UNCONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (from LTG -5-C) 0 AREA CATEGORY METHOD (from LTG -5-C) ALLOWED ❑ TAILORED METHOD from LTG -5-C): WATTS ALLOWED LIGHTING POWER 4,669 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMON LIGHTING SYSTEM (from LTG -8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES (from LTG -5-C) 4668.8 WATTS MANDATORY AUTOMATIC CONTROLS MANDATORY INTERIOR AND DAYLIGHTING AUTOMATIC CONTROLS INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES ( From LTG -2-C) 4626 PORTABLE LIGHTING (From LTG -3-C) p LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) p CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 4,626 INSTALLED LIGHTING, UNCONDITIONED SPACES ( From LTG -2-C) p LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) p UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER p ALLOWED INTERIOR LIGHITNG POWER FOR UNCONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (from LTG -5-C) 0 AREA CATEGORY METHOD (from LTG -5-C) ALLOWED ❑ TAILORED METHOD from LTG -5-C): WATTS ALLOWED LIGHTING POWER 4,669 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMON LIGHTING SYSTEM (from LTG -8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES (from LTG -5-C) 4668.8 WATTS MANDATORY AUTOMATIC CONTROLS MANDATORY INTERIOR AND DAYLIGHTING AUTOMATIC CONTROLS 2005 Nonresidential Compliance Form April 2005 CONTROL TYPE (Auto Time Switch, Dimming, . Photosensor, etc. If Control is for Da li htin NOTETO FIELD CONTROL LOCATION ROOM # CONTROL IDENTIFICATION SPACE,R Lists the location of controlled lights ELEC. ROOM L.C.P L.C.P ALL SPACES 2005 Nonresidential Compliance Form April 2005 1�- CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG - 1-C UA IL PROJECT NAME PACIFIC WESTERN BANK 06/27/06 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for the lighting syste The designer is required to check the boxes by all acceptance tests that.apply and list all equipment that require an acceptance to if all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheseis. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Al indicate the person responsible for performing the test (i.e. the installing contractor, design professional or an agent selected by th owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Systems Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditi system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified a meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A, Forms shall be submitted to the bulding department that: A. Certifies plans, specifications, installations certificates, and operating and maintenance information meet the requirem of 10-103(b) and Title 24 Part 6. Test Description Test Performed By: LTG -2-A: Lighting Control Acceptance Document • Occupancy Sensor Acceptance. ®' Manual Daylight Controls Acceptance e Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ALL TEST TO BE PROVIDED BY ON SITE CONTRACTOR ❑ LTG -3-A: Automatic Daylight Controls Acceptance Document Equipment requiring acceptance testing 2005 Nonresidential Compliance Form April 2005 INTERIOR LIGHTING SCHEDULE Part 1 of 2 LTG - 'ROJECT NAME PACIFIC WESTERN BANK 06/27/06 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lamps/ Ballasts A B C D E F G H NAME r • E czz . Q � ;x n E c A 2'X4' PARABOLIC FIXTURE FLUOR 3 2 71 Y 39 2769 C CLUB PENDANT INCAN 1 60 Y 3 180 D LASER DECO MR -16 1 50 Y 5 250 E VENEZIA WALL FIXTURE FLUOR 1 1 26 Y 3 78 F 8" RECESSED CFL FLUOR 1 1 32 Y 8 256 G CLARIS SUSPENDED FIXTURE FLUOR 4 2 54 Y 4 216 H 8" RECESSED DOWNLIGHT FLUOR 1 1 42 Y 1 42 I 2" PIN HOLE FIXTURE INCAN 1 50 Y 2 100 K COVE LIGHT 15 Y 25 375 L . VANITY LIGHT BAR INCAN 3 180 2 360 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r 0 0 0 0 0 0 0 0 0 PAGE TOTALS BUILDING TOTAL (sum of all pages) PORTABLE LIGHTING (from LTG -3-C) CONTROL CREDIT (from LTG -4-C) ADJUSTED ACTUAL WATTS 4626 4626. 0 0 4,626_ .2005 Nonresidential Compliance Form 5 April 2005 INTERIOR LIGHTING POWER ALLOWANCE LTG.- 5 - PROJECT NAME PACIFIC WESTERN BANK 06/27/06 ALLOWED LIGHTING POWER (Choose One Method) COMPLETE BUILDING METHOD- CONDITIONED SPACES WATTS COMPLETE ALLOWED BUILDING CATEGORY From 146 Table 146-B PER SF BLDG.ARE WATTS 0 COMPLETE BUILDING METHOD- CONDITIONED SPACES A B C D AREA CATEGORY From 146 Table 146-C WATTS PER SF AREA SF ALLOWED WATTS OFFICE 1.1 1136 1249.6 - SUPPORT 0.6 390 234 FINANCIAL TRANSACTIONS. 1.2 2232 2678.4 CONFERENCE ROOM 1.4 362 506.8 0 0 0 0 0 0 0 0 0 4120 11 4668.8 (TAILORED METHOD- CONDITIONED SPACES I TOTAL ALLOWED WATTS (From LTG -6-C) UNCONDITIONED SPACES A B C D Complete Building and Area Category Methods CATEGORY (From 146 Table 146-B & C) WATTS PER (SF) AREA (SF) ALLOWED WATTS 0 0 0 0 0 0 TOTALS AREA WATTS ITAILORED METHOD- UNCONDITIONED SPACES I TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTU -5-C and LTG -6-C) 2005 Nonresidential Compliance Form April 2005 PROJECT NAME: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT Bro BY I .GU;4— 110 -2— T -:T--.. PACIFIC WESTERN BANK 78080 CALLE ESTADO, LA QUINTA, CA 92247 ACCO JOB - 712340 MECHANICAL TITLE 24 CERTIFICATION PRESCRIPTIVE APPROACH 7/17/2006 DOCUMENTATION AUTHOR MICHAEL G. LAYTON ACCO Engineered Systems (949) 786-1063 uPFfK R -CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C PROJECT NAME PACIFIC WESTERN BANK Certificate of Compliance. Part 1 of 3, 2 of 3, 3 of 3 are required on plans for all submittals [KMECH-2-C DATE 7/17/2006 PROJECT ADDRESS 78080 CALLE ESTADO LAQ UINTA CA 92247 Certificate of Compliance are required for all submittals with mechanical ventilation, but may be on plans. QMECH-4-C ::�1JILF)IIk1G:1?�KIxxij.................:: ii �::�::�:Gt�Cit >�rDa"Cep:::::::::::::::::::::>�`�>'• Ettfof PROJECT DESIGNER -MECHANICAL ACCO Engineered Systems ms TELEPHONE 949 8 - 7 6 1063 DOCUMENTATION AUTHOR MICHAEL G. LAYTON TELEPHONE (949) 786-1063 GENERAL INFORMATION DATE OF PLANS 7/17/2006 BUILDING CONDITIONED FLOOR AREA 3,438 SQ. FT. CLIMATE ZONE i5 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ® ALTERATION UNCONDITIONED (file affidavit) PROOF OF ENVELOPE COMPLIANCE X PREVIOUS ENVELOPE PERMIT ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24 Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 101, 102, 110 through 115, 120 through 125, 142, 144, and 145. © The plans & specifications meet the requirements of Part 6 (Sections 10-103a). The installation certificates meet the requirements of Part 6 (10-103a 3). Q The operation & maintenance information meets the requirements of Part 6 (10-103c). Please check one: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑X I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or mechanical engineer, or I am a licensed architect. I affirm that I am eligible under the exemption to Division 3 of the business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to business and Professions Code section 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAMEDATE LIC. # IGN T E JOHNNY BONCICH 7/17/2006 1 M25893 FX Indicate location on plans of Note r Mandatory Measures TO.01 INSTRUCTIONS TO APPLICANT MECHANICAL COMPLIANCE & WORKSHEETS (check box if worksheet included) QX MECH-1-C Certificate of Compliance. Part 1 of 3, 2 of 3, 3 of 3 are required on plans for all submittals [KMECH-2-C Certificate of Compliance. Part 1 of 3, 2 of 3, 3 of 3 are required for all submittals, but may be on plans. QX MECH-3-C Certificate of Compliance are required for all submittals with mechanical ventilation, but may be on plans. QMECH-4-C Certificate of Compliance are required for all prescriptive submittals, but may be on plans. 2005 Nonresidential Compliance Forms Manch 2005 CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-1-C PROJECT NAME DATE PACIFIC WESTERN BANK 7/17/2006 Designer: This form is to be used by the designer and atached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A, Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title 24 Part 6. Test Desciption Test Performed By: QMECH-2-A: Ventilation System Acceptance Document • Variable Air Volume Systems Outdoor Air Acceptance • Constant Air Voume Systems Outdoor Air Acceptance Equipment requiring accptance testing FC-1, AC-1, AC-2, AC-3, AC-4, AC-5 F-]MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring accptance testing 4 F-]MECH-4-A: Air Distribution Acceptance Document Equipment requiring accptance testing 4 F-1MECH-5-A: Air-Side Economizer Acceptance Document Equipment requiring accptance testing 4 F-JMECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring accptance testing 2005 Nonresidential Compliance Forms March 2005 CERTIFICATE OF COMPLIANCE (Part 2 of 2 Cont'd) MECH-1-C PROJECT NAME DATE PACIFIC WESTERN BANK 7/17/2006 Test Desci tion Test Performed By: 4 F�MECHJ-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring accptance testing J F-IMECH-8-A: Hydronic System Control Acceptance Document • Variable Flow Controls • Automatic Isolation Controls • Supply Water Temperature Reset Controls • Water -loop Heat Pump Controls • Variable Frequency Control Equipment requiring accptance testing 2005 Nonresidential Compliance Forms March 2005 AIR SYSTEM REQUIREMENTS (Part 1 of 3) MECH-2-C PROJECT NAME DATE PACIFIC WESTERN BANK 7/17/2006 AIR SYSTEMS, Central or Single Zone " ITEM or SYSTEM TAG(S) FC -1 AC -1 thru AC -5 T-24 (EXISTING) MANDATORY MEASURES Section Reference on Plans or Specification' Heating Equipment Efficiency 112(a) N/A N/A (Existing) Cooling Equipment Efficiency 112(a) T0.02 N/A (Existing) Heat Pump Thermostat 112(b) N/A T0.01 Furnace Controls 112(c), 115(a) N/A N/A Natural Ventilation 121(b) N/A N/A Minimum Ventilation 121(b) T0.02 T0.02 VAV Minimum Position Control 121(c) N/A N/A Demand Control Ventilation 121(c) N/A N/A Time Control 121(c), 122(e) T0.01 T0.02 Setback and Setup Control 122(e) T0.01 T0.02 Outdoor Damper Control 122(f) T0.01 N/A Isolation Zones 122(g) N/A N/A Pipe Insulation 123 T0.01 T0.01 Duct Insulation 124 N/A T0.01 PRESCRIPTIVE MEASURES Calculated Heating Capacity2 144(a&b) N/A N/A (Existing) Proposed Heating Capacity2 144(a&b) N/A N/A (Existing) Calculated Cooling Capacity2 144(a&b) 16,000 N/A (Existing) Proposed Cooling Capacity2 144(a&b) T0.02 N/A (Existing) Fan Control 144(c) N/A N/A (Existing) DP Sensor Location 144(c) N/A N/A (Existing) Supply Pressure Reset (DDC Only) 144(c) N/A N/A (Existing) Simultaneous Heat/Cool 144(d) N/A N/A (Existing) Economizer 144(e) N/A N/A Heat and Cool Air Supply Reset 144(f) N/A N/A (Existing) Duct Sealing 144(k) N/A I N/A (Existing) 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for h dronic heating or cooling. Either enter value here or put in reference to plans and sp ecifications per footnote 1. 2005 Nonresidential Compliance Forms March 2005 WATER SIDE SYSTEM REQUIREMENTS (Part 2 of 3) MECH-2-C PROJECT NAME DATE _ PACIFIC WESTERN BANK 1 7/17/2006 WATERZ SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops ITEM or SYSTEM TAG(S) MANDATORY MEASURES T-24 Section Reference on Plans or Specification' Equipment Efficiency 1112(a) Pipe Insulation 1123 PRESCRIPTIVE MEASURES Calculated Capacity 144(a & b) Proposed Capacity 144(a & b) Tower Fan Controls 144(h) Tower Flow Controls 144(h) - Variable Flow System Design 144(j) Chiller and Boiler Isolation 144(j) CHW and HHW Reset Controls 1440) WLHP Isolation Valves 1440) VSD on CHW, CW & WLHP Pumps > 5HP 1440). DP Sensor Location 1440) 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water sides stems include wet sides stems using other liquids such as glycol or brine. 2005 Nonresidential Compliance Forms March 2005 SERVICE HOT WATER & POOL REQUIREMENTS (Part 3 of 3) MECH-2-C PROJECT NAME PACIFIC WESTERN BANK DATE - 7/17/2006 ITEM or SYSTEM TAG(S) MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light I - ------ Service Hot Water, Pool Heating WH -1 I I F T-24 Section Reference on Plans or Specification' §113 (a) surface mount T'stat §113 (b) 90.0% §113 (c) surface mount T'stat §114 (a) n/a §114 (b) n/a §115 (c) n/a §115 (d) n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2005 Nonresidential Compliance Forms March 2005 MECHANICAL VENTILATION AND REHEAT Minimum ventilation rate per Section §121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G). I Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or MECH-3-C MOJECTNAWar£ PACIFIC WESTERN BANK L Maximum of Columns H, J, K, or 300 cfm M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N. - N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (Column H) and the Design Minimum Air (Column M), Column H minus M. 7/17/2006 MECHANICAL VENTILATION (§121(b)2) REHEAT LIMITATION(§144(d)) AREA BASIS Occupancy Basis VAV Minimum A B C D E F G H I J K L M N Condition Zone/ Area System (ft) CFM per ft Min CFM by Area B x C Num of People CFM per Person I Min CFM by Occupant E x F REQ'D V.A. Max Of D or G Design Ventilation Air CFM 30% of Design Zone Supply CFM B x 0.4 cfm/ft2 Max of Columns H, J. K or 300 CFM CFM Design minimum Air setpoint Transfer Air FC -1 163 0.15 24 1 15 15 24 25 124 65 300 25 (E)AC-1 595 0.15 89 14 15 210 210 210 277 238 300 210 (E)AC-2 661 0.15 99 7 15 99 99 100 293 264 300 100 (E)AC-3 670 0.15 101 7 15 105 105 105 252 268 300 105 (E)AC-4 731 0.15 110 7 15 110 110 110 268 292 300 110 (E)AC-5 717 0.15 108 7 15 108 1 108 110 361 287 361 110 Totals (this page only)1 43 1 656 1 660 lColumn I Total Design Ventilation Air I C Minimum ventilation rate per Section §121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G). I Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area(ft) x 0.4 cfm/ft2; or L Maximum of Columns H, J, K, or 300 cfm M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N. - N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (Column H) and the Design Minimum Air (Column M), Column H minus M. 2005 Non2siden0al Compliance Forms March 2005 MECHANICAL VENTILATION AND REHEAT (Part 2 of 2) MECHr3-C PACIFIC WESTERN BANK_ DATE 11 VENTILATIONMECHANICAL Occupancy 0 0 0 0 ©0 0 ©0 0 ©0 Conditionf Zone/ Area System (ft2) CFM by Nurn of Area People per Person CFM b Occupant •. V.A. Max Of DorG .. Design Zone Supply CFM Max of Columns B x 0• H, 1, K CfM/ft2 or 300 CFM CFM Design minimurn Air setpoint Transfer Air -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- -------------- Totals (this page only)( I I I (Column I Total Design Ventilation Air I I 2005 Nonresidential Compliance Forms March 2005 HVAC MISC. PRESCRIPTIVE REQUIREMENTS: MECH-4-C PROJECT NAME DATE PACIFIC WESTERN BANK 7/17/2006 FAN POWER CONSUMPTION §144(c) NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater that 25 hp for Constant Volume Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. 0 0 o a o 0 FAN DESCRIPTION DESIGN EFFICIENCY NUMBER PEAK WATTS T-24 Section BRAKE HP MOTOR DRIVE OF FANS B x E x 746/ (C x D) FC -1 < 25 HP §144 (h) AC -1 thru AC -5 < 25 HP 1) TOTAL FAN SYSTEM POWER (WATTS< SUM COLUMN F) FILTER PRESSURE ADJUSTMENT Equation. 144-A 2) SUPPLY DESIGN AIRFLOW (CFM) A) If filter pressure drop is greater than 1 inch W. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2)' #DIV/0! W/CFM C. enter filter pressure drop. SP, on line 4 and Total Fan pressure SPI on Line 5. 4) SPa B) Calculate Fan Adjustment and enteron line 6. 5) SP, 6) Fan Adjustment = 1 - (Spa - 1) / SP, #DIV/0! C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' #DIV/0! W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 w/cfm, for CV systems or 1.25 w/cfm for VAV systems. ITEM or SYSTEM TAG(S) PRESCRIPTIVE MEASURES Reference on Plans or Specification' T-24 Section Electric Resistance heating2 Heat Rejection Systema Air Cooled Chiller Limitation §144 (g) §144 (h) §144 (1) 1. Fill in the reference sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is no applicable, put "N/A" in the column. 2. Total installed capacity (Mbtu/hr) of all electric heat on this project exclusive of electric auxilary heat for heat pumps if electric heat is used explain which exception(s) to §144(g) apply. 3. Are centrifugal fan cooling towers used on this project? (Enter "Yes" or "No") If centrifugal fan cooling towers are used explain which exception(s) to §144(h) apply. 4. Total installed capacity (tons) of all chillers and air cooled chillers under this permit, If there are more than 100 tons of air-cooled chiller capacity being installed explain which exception(s) to §144(1) apply. 2005 Nonresidential Compliance Forms March 2005 Rheem Water Heaters pwznzzzz�pw�v® 101 BELL ROAD • MONTGOMERY, AL 36117 • Phone (334) 260-1500 March 1, 2005 To whom it may concern: RE: Efficiency Compliance Please be advised that all residential gas and electric water heaters manufactured for sale within the United States by Rheem Manufacturing Company are in compliance with the provisions of the National Appliance Energy Conservation Act of 2004 (NAECA). This Federal law administered by the Department of Energy prescribes minimum efficiency standards for all water heaters from 20 to 120 gallons capacity and with input rating up to 75,000 BTU. Please fell free to contact your local Rheem representative for more information or specifications. Regards, Shaun Thomas Residential Product Specialist VV VIAX � qiTl- VWt-, vs t -w engineered SUBJECT: systems JOB NAME-: (�o t,4q—\.P, • Glendale/L.A. 818-244-6571 * San Leandro 510-346-4300 JOB NO: • San Diego 858-695-3977 9 Sacramento 916-852-5050 0 • Orange County 949-786-1063 * Bakersfield 661-631-1975 CONT . LIC: CA #1 . 20696 • Seattle/Tacoma 253-854-8444 * Fresno 559-251-2226 WA IMP.r.nFCM7 i ni i