Loading...
07-2782 (RC)'P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Appljcatjon Number: _ 07-00002782'"' 1 Property Address: 78115 CALLE ESTADO ST(C)4 APN: 770-152-010- - Application description: REMODEL - COMMERCIAL Property Zoning: VILLAGE COMMERCIAL Application valuation: 2000 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT !D Owner: CALLE ESTADO LLC. 52-050 INDUSTRAIL WA; COACHELLA, CA 92236jr) Contractor: Applicant: Architect or Engineer: SANTA ROSA BUILDERS, 78115 CALLE ESTADO, - a LA QUINTA, 92253 L (760)972-6494 Lic. No.: -B ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. LicenseClass: �814110 License No.: B D� a�V -V—Contractor: 4— ■ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the ' - following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to ' construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and -t the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The . Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT' s VO CE (760) 777-7012 (760) 777-7011 LCTIFOVS (760) 777-7153 Date: 11/08/07 �� �:� 2001Ciry NJFLA INC. #204 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section I ,3700 of the Labor Code, I Pe4,forthwith comply with those provisions. Date:-'/ '/,--kr Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shalt defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property.Aor inspection purpose�� Application Number . . . . . 07-00002782 Permit . . . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 45.00 Plan Check Fee 29.25 Issue Date . . . . Valuation 2000 Expiration Date 5/06/08 Qty Unit Charge Per, Extension BASE FEE 15.00 15.00 2.0000 ---------------------------------------------------------------------------- HND BLDG 501-2,000 30.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee' 23.42 Plan Check Fee 5.86 Issue Date Valuation . . . . 0 Expiration. Date ., S/06/08 Qty Unit Charge Per Extension BASE FEE 15.00 421.00 0200 ------------------------------------------ ELEC GARAGE OR NON-RESIDENTIAL ---------------------------------- 8.42 Permit . . . . MECHANICAL Additional desc . Permit Fee . . 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 Expiration Date.. 5/06/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 -----------------------------7---------------------------------------------- Special Notes and Comments . 421 SQ. FT. TENANT IMPOVEMENT ,MORTGAGE ADVISERS OFFICES. 1 Fee summary Charged ----------------- ----- Paid Credited - Due ---------- Permit Fee Total 92.42 ---------- ---- ---------- .00 .00 92.42 P1an.Check Total 41.11 .00 .00. _ 41.11 Grand Total 133.53 .00 .00 133.53 LQPERAIIT Bin #�-�� �,� City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # / ��I/ Project Address: _ <4((,- 4,45 7'4J)40 Owner's Name: CAA t C S r7 �� C A. P. Number: 77()_ ^Z_ olo F 40 D Address: S-Z/J 4VJ f L WAY Legal Description: -,_City, Contractor: ST, Zip: Co A <#4f- �A cA Z Z 36 Telephone: Address: C6 U Project Description: City, ST, Zip: 0 SQ �'&WGC O >NA /QQ (%7-6 IJMNWOUVA� Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: 5401/ Wc�s� CQ^%C�� e � /EN • Address: 7,1--12,0 C 4t4 & S1*.to S7'dc 2 •�Q/kF/t/SAN / vA G A c -A city, ST, zip: 41-Av/1v PA GA e9 Z L$-3 Telephone: t 24v 6 y- y7V7 Construction Type: Occupancy: State Lic. #: <f 0 Q 6 Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person:"�,Q ^% / 7v Sq. Ft.: # Stor' # U Telephone # of Contact Person: S 6 Estimated Value of Project, ,Soo b APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING. PERMIT FEES Plan Sets I-- Plan Check submitted o t, Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"° Review, ready for corrections/issue Electrical Ar Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for corrections/i s e Developer Impact Fee Planning Approval Called Contact Person 1. e>rI Pub. Wks. Appr Date of permit issu School Fees cJ i3 v [/t{ �6Q 'r4 d 11wof , Total PcpTiNes 1P N D* if P" 0 vitt 57 O t 07 ll�n'7 wb ;h. ticenio (589920'' October 22, 2007 Attn: Building Department C/o City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Project: Plaza Estado, 78-115 Calle Estado, La Quinta, CA 92253. RE: Tenant Improvement Permits To Whom It May Concern, Asaro Builders, Inc. is hereby giving written notice to The City of La Quinta Building Department that we are NOT currently the "Contractor of Record" for the tenant improvements, for suites #201 & 202. Please remove are name from this permit. Additionally, please note we are NOT currently the "Contractor of Record" for suites #101, 102, 103, 104, 105, 106, 107, 203, 204 & 205. The only suite we ARE currently "The Contractor of Record" for, is suite #206 and we remain- the emainthe "Contractor of Record" for the building shell. We hope this clears up any confusion that may arise. Respectfully, Asaro Builders Inc. Jim Huffman Sr. Project Manager cc: Stan'Asaro File z a'zou, D 42-220 GREEN WAY, SUITE H, PALM DESERT, CA 92211, (760) 776-0043 FAX (760) 837-1049 I. TITLE 24 REPORT I .:r�7 SEP 2 0 [U07 Title 24 Report for: Calle Estado, LLC Desert Club Dr. & Calle Estado La Quinta, CA 92253 . rwmoet ProJ9'ectDes�i ne South West Concects 78-120 Calle Estado, Suite 206 La Quinta, CA 92253 (760) 564-4707 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 6/13/2007 cop' ON��/ EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is ;u,thorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. 1 EnergyPro 4.3 by EnergySoft Job Number: User Number. 6712 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM Envelope Mandatory Measures Form LTG -7-C Room Cavity Ratio Worksheet Form OLTG-1-C Certificate of Compliance Form OLTG-2-C Lighting Compliance Summary Form OLTG-3-C Illuminated Area Calculation Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room .Load Summary Room Heating Peak Loads Room Cooling Peak Loads Room Cooling Coil Loads 1 2 3 27 28 29 31 32 33 34 36 49 62 75 89 I EnergyPro 4.3 by Energy5oft Job Number: User Number. 6712 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME DATE Calle Estado, LLC 6/13/2007 PROJECT ADDRESS:,__::,; Desert Club Dr. & Calle Estado La Quinta ;_wilding=Ferplit # :j;: — PRINCIPAL DESIGNER -ENVELOPE TELEPHONE South West Concects (760) 564-4707 DOCUMENTATION AUTHOR TELEPHONE raRCleckedIiy/,Da Scott Design & Title 24 (760) 200-4780 r _EnforcemeritlA GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR DATE OF PLANSBUILDING DATE Tim Scott CONDITIONED FLOOR AREA 9,048 Sq,Ft 7CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION contractor performing this work. EXISTING + ADDITIONIALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE Tim Scott The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. pr -j ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. El. ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. n ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE South West Concects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1, LTG -2, LTG -3 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE Heme Electrical Contractors MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE H & H Air Conditioning EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:3 of 102 1 PERFORMANCE CERTIFICATE OF -COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME 1 Calle Estado, LLC ANNUAL TDV ENERGY USE SUMMARY (kBtu/sgft-yr) 01 ENERGY COMPONENT Standard Design Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type Proposed Desig6 sqft. sqft. sgft. Compliance Margin 0 I� "S'�i-anndards Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. ' Domestic Hot Water Lighting Receptacle Process 1.46 1.29 0.18 4" . R�tttiw�+--3 204.60 194.26 10.34 53.98 57.67 -3.69 0.00 0.00 0.00 0.00 0.00 0.00 , 16.17 16.31 -0.14 .. 72.98 75.14 -2.16 t.. f22 .•�u��-�� 81.78 81.78 0.00," 4.90 4.90 0.00 TOTALS: Percent better than Standard: 435.87 431.34 • 4.53 1.0% ( 1.1% excluding process) DATE 7 Building Orientation Number of Stories Number of Systems Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 9,048 sqft. sqft. sgft. 2 0 14 5,402 131 Natural Gas Glazing Ratio Standard Proposed Lighting, Power Density 1.100 wisgft. 1.133 w/sgft:, Prescriptive Env. Heat Loss 2,192 Btu/, 2,075 Btuih Prescriptive Env. Heat Gain 226,727 Btu/h-F 217,905 Btu,th-F Remarks: t Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:4 of 102 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N 3,065 sqft. 11,260 sqft. 41.1% Left Elevation (E) 1,770 sqft. 233 sqft. 13.2% Rear Elevation S 3,135 sqft. 586 sgft. 18.7% Right Elevation (W) Total Roof 1,870 9;840 5,411 ,sqft. sift. sqft. 80 2,158 E::� sgft. sqft' sqft. 4.3% 0.0% Standard Proposed Lighting, Power Density 1.100 wisgft. 1.133 w/sgft:, Prescriptive Env. Heat Loss 2,192 Btu/, 2,075 Btuih Prescriptive Env. Heat Gain 226,727 Btu/h-F 217,905 Btu,th-F Remarks: t Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:4 of 102 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME DATE Calle Estado, LLC 6/13/2007 �'i LONE INFORMATION Floor Inst.;Ctl,?a:�s` =Allowed Area LPD Credtts Atea Tallbf0d:o�iS: System Name S Y Zone Name Occupancy TypeWe)' P Y YP (sgft.) (W e)1 t F(VI►/sf)? UVl5, t3 ' Wls 4{ (W/,sf) HVAC -4 Suite 101 Comp Bldg Office 820 0.794 yilN."_±j `" i!a1LL HVAC -2 Suite 102 Comp Bldg Office 433 1.28 HVAC -2.5 i e 1 Sut 03 Com Bldg Office 484 1.28 =:y z:+ �;,"_ rfi-: ==.:1 500! i:i ,..:, .,: J.::..._.. ,.:. .,_. t. _... _. :. _., r_.. .. _.,..�.r HVAC -2 Suite 104 Comp Bldg Office 484 1 28 - HVAC -2 Suite 105 Comp Bldg Office 433 1.284::.::....::. ..::;, .; .:,,,,u:.., tr:::, HVAC 2.5 Suite 106 Com BldgOffice 578 1.28x,,_..:._:. it r:.;,,.__!.`_'_ ; ,..,, C�. _ :..'.!t,,.'r' HVAC 2 Suite 107 Comp Bldg Office 405 1.378 j'kr' HVAC -3 Suite 201 Comp.131dg Office 619 1.05 '41} HVAC -3 Suite 202 Comp Bldg Office 728 Suite 203 HVAC -3 Comp Bldg Office 781 1.27. HVAC -4 Suite 204 Comp Bldg Office 860 1.2641111,11M _urt HVAC -4 Suite 205 Comp Bldg Office 1,733 0.93 u� f HVAC -3.5 Suite 206 Comp Bldg Office 690 1.07 7r t= rata ?1 tti "j J +�..:..: :.:. r.i_ aa,.,,, .: �....: n.. _.. I�• nth I trt is -ti+i,: � � S it',{1�t�1i,1! � M �J ,z'4id:�i �._ h 071 :n ,.:,r.'i;!f`S''+i'=:c•-4-.T,=:yam ''jrr3?_ ` Fipj -!IL , : i- FP }•Ir ;il' aril a (� � ",- 'i ,E �, �t r;�.,',. Notes: 1. See LTG -2-C 2. See LTGA-C 3. See LTG -5-C 4. See LTG -6-C —a:::µ :=:r=!?;=.H=;,: ='sat• 8 ; rsn.:",_,: 4.teiris7above requl[epsp '6W docurrientalion?�( (items marked with asterisk, see LTG -2 -C by others) (by others) ,: K EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Carrier 38YRA02433" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 38YRA04833" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 38YRA03033" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0365" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0485" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0423" includes Demand Control Ventilation per Standards Section 121. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and -i t cumentation for their use have been provided by the applicant. 'Authorized Signature or Stamp EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page:5 of 102 1 (CERTIFICATE OF COMPLIANCE ENVA -CI ECT NAME Calle Estado, LLC DATE 6/13/2007 # 1 Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond. Status Joint Appendix IV Reference Location / Comments 1 lWall 176 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 101 2 Wall 64 0.074 R-19 R-0.0 45 90 New 09-A5 Suite 101 3 Wall J' 164 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 101 4 Wall J, 346.0.074 N R-19 R-0.0 180 90 New 09-A5 Suite 101 5 Wall 11 0.074 R-19 R-0.0 270 1 90 New 09-A5 Suite 101 6 Wall 6 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 102 7 Wall 110 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 102 8 Wall 134 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 103 9 Wall 181 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 103 10 Wall 241 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 103 11 Door 24 1.450 None R-0.0 270 90 New 28-A1 ISuite 103 12 lWall ' 131 0.074 R-19 R-0.0 0 1 90 New 09-A5 Suite 104 13 Wall 26 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 104 14 Wall 181 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 104 15 Wall 6 0.074 R-19 R-0.0 0 90 New 09-A5 ASuite Suite 105 16 Wall / 11A 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 105 17 Wall 11 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 106 18 Wall 3 0.074 R-19 R-0.0 90 90 New 09-A5 106 19 iWall 291 0.074 R-19 R-0.01 270 1 90 1 New 09-A I Suite 106 20 lWall 9 0.074 R-19 R-0.01 90 1 90 1 New 09-A5 ISuite 107 N. E. A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES I I More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building manager's office after construction # TvDe Area U -Fac' SHGC2 Act. Am- Cond. Stat. Glazing Type Location/ Comments Window Front N 24 0.580 116-A 0.53 116-B 0 New Double on Metal Tinted Suite 101 indow Front N 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 101 3 Window Front (N) 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 101 4 Window Front N 36 0.580 116-A 0.53 116-13 0 New Double Non Metal Tinted Suite 101 5 Window Front NE 36 0.580 116-A 0.53 116-B 45 New Double Non Metal Tinted Suite 101 6 Window Left E 36 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 101 7 Window Rear S 20 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 101 8 Window Rear S 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 101 9 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 102 10 Window Front (N) 48 0.580 116-A 0.53 116-B 01 New Double Non Metal Tinted Suite 102 11 Window Front (N /, 24 0.580 116-A 0.53 116 -BI 01 New I Double Non Metal Tinted Suite 102 12 Window Rear S 24 0.580 116-A 0.53 '116-B 1 1801 New I Double Non Metal Tinted ISuite 102 13 Window Rear (SY 251 0.5801116-A_0.53 1116-131 1801 New I Double Non Metal Tinted I Suite 102 1] LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2) SHGC Type: 116.8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 2 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 3 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 4 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 5 None / 0.76 6.0 6.0 2.0 0.1 2.0 2.0 6 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 7 None 0.76 5.0 4.0 10.0 0.1 10.0 10.6-- 8 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 9 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 10 None / 0.76 8.0 6.0 2.0 0.1 2.0 2.0 11 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 12 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 13 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 I NIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with Floor area greater than 25,000 ft2, a lighting of at least 0.5 W111:2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out when submitting under the Pn greater than 15 feet, and an LPD for general ipllance Approach. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:6 of 102 1 CERTIFICATE OF COMPLIANCE ENVA -C' -I?ROJECT NAME DATE r) Calle Estado, LLC 6/13/2007 Surface # Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 21 Wall21 4 Window Front 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 107 22 Wall Window 19 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 107 23 Roof fib Window 61 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 201 24 Wall 01 139 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 201 25 Wall 18 Window 64 0.074 R-19 R-0.0 45 90 New 09-A5 Suite 201 26 Wall 19 Window 124 0.074 R-19 R=0.0 90 90 New 09-A5 Suite 201 27 Wall 20 lWindow 280 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 201 28 Roof 21 Window 724 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 202 29 Wall .1 6 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 202 30 Wall v 20 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 202 31 Wall i 15 0.074 R-19 R-0.0 180 1 90 New 09-A5 Suite 202 32 Floor / 28 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 202 33 Roof 26 Window 78 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 203 34 Wall 13 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 203 35 Wall 17 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 203 36 Wall 11 360 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 203 or 24 1.450 None R-0.0 270 90 New 28-A1 Suite 203 i 26 0.037 R-19 R-0.0 0 180 New 20-A4E Suite 203 440Wall 86 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 204 13 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 204 N, E. A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES 171 More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default 11 -factors from Standards Table 116-A and B. Certificate shall be filed In the contractors project office during construction and in the building manager's office after construction # Tvi3e Area U -Fac' SHGC2 Act. Am. I Cond. Stat. Glazing Type Location/ Comments 4 Window Front N None 24 0.580 116-A 0.53 116-6 0 New Double Non Metal Tinted Suite 103 Window Front N / 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 103 fib Window Front N / 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 103 17 Window Rear S / 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 103 18 Window Rear S 0.1 25 0.580 116-A 0.53 116-B 180 New I Double Non Metal Tinted Suite 103 19 Window Front N 21 24 0.580 116-A 0.53 116-B 0 New I Double Non Metal Tinted Suite 104 20 lWindow Front N i1 48 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 104 21 Window Front N / 24 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 104 22 Window Rear S NoneE 25 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 104 23 Window Rear(S)--7-24 8.0 3.0 2.0 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 104 24 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Isuite 105 25 Window Front N 48 0.580 116-A 0.53 116-B 01 New Double Non Metal Tinted ISuite 105 26 Window Front N 24 0.580 116-A 0.53 116 -BI 01 New I Double Non Metal Tinted I Suite 105 �1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2; SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 14 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 15 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 16 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 17 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 18 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 19 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 20 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 21 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 22 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 23 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 24 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 25 NoneE 0.76 8.0 6.0 2.0 0.1 2.0 2.0 26 None 1 0.76 1 8.0 3.0 2.0 0.1 2.0 2.0 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES •l The proposed building Is'In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 112, a ceiling height greater than 15 feet, and an LPD for general U lighting of at least 0.5 W/ft2. See Section 143(c). It this box Is checked, ENV4-C must be filled out, when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:7 of 102 CERTIFICATE OF COMPLIANCE ENV -1 -C PROJECT NAME DATE I Calle Estado, LLC 6/13/2007 OPAQUE SURFACES Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 1,7 Window Rear S 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 105 Surface # Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Con& Status Joint Appendix IV Reference Location •/ Comments • 41 Wall 36 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 204 42 Door 2 1.450 None R-0.0 90 90 New 28-A1 Suite 204 43 Wall 24 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 204 44 Floor / 26 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 204 45 Roof 1,731 0.036 R-30 R-0.0 0 1 0 New 02-A9 Suite 205 46 Wall f . 180 0.074 R-19 R-0.0 0 1 90 New 09-A5 Suite 205 47 Wall 9 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 205 48 Wall 30A 0.074 R-1 91 R-0.0 180 90 New 09-A5 • Suite 205 49 Wall 510 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 205 50 Floor 261 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 205 51 Roof 69C 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 206 52 Wall 32C 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 206 53 Wall i 17E 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 206 54 Wall 232 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 206 55 Wall 13C 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 206 56 Floor 69C 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 206 N. E, A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES ❑More than or equal to 10,000 sq.fi.of site -built fenestration area must include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction # Tvve Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 1,7 Window Rear S 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 105 Window Rear S 24 0.580 116-A 0.53 116-B 180 New Double on Metal Tinted Suite 105 29 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 30 Window Front N 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 31 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 32 Window Left E 24 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 107 33 Window Left E) 48 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 107 34 lWindow Left E 24 0.5801116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 107 35 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 201 36 Window Front N 48 0.580 116-A 0.53 116-B 0 New I Double Non Metal Tinted Suite 201 37 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 201 38 Window Front NE 36 0.580 116 -Al 0.53 116-B 45 New Double Non Metal Tinted Suite 201 39 Window Left (E) 1 36 0.580 116 -Al 0.53 116-B 1 90 New I Double Non Metal Tinted Suite 201 �1 -tactor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2; LI -factor SHGC Type: 116-5 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hc it. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 27 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 28 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 29 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 30 1 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 31 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 32 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 33 None 0.76 8.0 6.0 10.0 0.1 10.0 10.0 34 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 35 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 36 None 10.76 1 8.0 6.0 1 2.0 0.1 2.0 2.0- 137 1 None 0.76 1 8.0 3.0 2.0 0.1 2.0 2.0 38 1 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 39 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 1112, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W1ft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out. when submitting under the Pirescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 102 1 CERTIFICATE OF COMPLIANCE ENV -1-C 1,PAQUE SURFACES IV Reference .. More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default Ll -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's project office during construction and in the building manager's office after construction # Tvve SHADING Area U -Fac' SHGC2 Act. Am. Cond. Stat. GlazingType Location/ Comments Window Rear S 40 24 0.5801116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 201 Window Front N , 24P0.5801116 -A 0.53 116-B 0 New Double Non Metal Tinted Suite 202 42 Window Front N i 48 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 202 43 Window Front N i 24 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 202 44 Window Rear S 4.0 30 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 202 45 Window Rear S 2.0 24 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 202 46 Window Front (N 0.76 24. 116 -Al 0.53 116-B 0 New Double Non Metal Tinted Suite 203 47 lWindow Front N / 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 203 48 Window Front N 51 24 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 203 49 lWindow Rear S 8.0 6.0 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 203 50 Window Rear S / 0 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 203 51 Window Front N 0.580 116-A �J4 0.53 116-B 0 New Double Non Metal Tinted Suite 204 52 Window Front N 8 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 204 1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 40 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 41 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 42 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 43 None 0.76 8.0 3.0 2.0 0.1 • 2.0 2.0 44 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 45 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 46 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 47 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 48 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 49 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 50 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 51 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 52 1 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 1INIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building is in climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 1`12, a ceiling height greater than 16 feet, and an LPD for general lighting of at least 0.5 WI112. See Section 143(c). If this box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paae:9 of 102 1 CERTIFICATE OF COMPLIANCE ENV -1 -C DROJECT NAME ,) Calle Estado, LLC OPAQUE SURFACES DATE 6/13/2007 # I Surface Insulation Act. Cond. Joint Appendix TvDe Area U -Fac. Cay. Cont. Azrn Tilt Status IV Referei I Location / Comments ' N, E. A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES FIr -t1 More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from I I Standard_n Tnhle I IR -A and R CPdifiratn shall ha (lad In thn cnntmr-tnrs nmi-t nffira dudnn rnnctn inlinn and in tha huildinn mananRes nffirn aft--..osfn,rfinn # Tvpe Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments 53 Window Front N s 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 204 Window Rear S 4.0 30 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 204 -55 Window Rear S 4.0 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 204 56 Window Front N 0.76 24 0.580 116 -Al 0.53 116-B 0 New I Double Non Metal Tinted Suite 205 0.76 Front N 0.1 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 dow Front N 60 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 dow Front N 8.0 3.0 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 dow Front N 4.0 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 fdow dow Front N 1 None 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 dow Left E 30 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 205 dow Rear S 48 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 205 dow Rear(S)-25 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 205 65 Window Left (E) 18 0.580 116 -Al 0.53 116-B 1 90 New I Double Non Metal Tinted I Suite 206 (1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2 SHGC Type: 1II&B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 53 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 54 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 55 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 56 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 57 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 58 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 59 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 60 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 61 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 62 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 63 1 None 0.76 8.0 6.0 4.0 0.1 4.0 4.0 64 1 None 0.76 5.0 5.0 4.0 0.1 4.0 4.0 65 None 0.76 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES - The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W1ft2. See Section 143(c). If this box Is checked, ENV41-C must be filled out when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 10 of 102 CERTIFICATE OF COMPLIANCE ENVA-C ].PROJECT NAME DATE l Calle Estado, LLC 6/13/2007 {OPAQUE SURFACES Surface Insulation Act. Cond: Joint Appendix # Type Area U -Fac. Cay. Cont. Am. Tilt Status IV Reference Location / Comments • N. E. A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's project office during construction and in the building manager's office after construction # TvDe Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments Q6 Window Left E 18 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 206 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 68 Window Rear S 18 0.580 116-A 0.53 116-B 180 New - Double Non Metal Tinted Suite 206 69 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 70 Window Rear S 18 0.580 116-A 0.53 116 -BI 180 New Double Non Metal Tinted Suite 206 71 Window Rear S 18 0.580 116-A 0.53 116 -BI 180 New 1 Double Non Metal Tinted Suite 206 72 lWindow Right W 161 0.5801116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 73 Window Right W 48 0.580 116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 74 Window Right, W 16 0.580 116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2; SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 66 None 0.76 67 None 0.76 68 None 0.76 69 None 0.76 70 None 0.76 71 None 0.76 72 None 0.76 8.0 2.0 10.0 0.1 10.0 10.0 73 None 0.76 8.0 6.0 10.0 0.1 10.0 10.0 74 None 0.76 8.0 2.0 10.0 0.1 10.0 10.0 -MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 WI112. See Section 143(c). If this box Is checked, ENV4-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 11 of 102 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C (PROJECT NAME DATE 1 Calle Estado, LLC 6/13/2007 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING.METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 10,248 �X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE Check if tOTEa[,Ot Room # IDENTIFICATION Auto Time Switch, Dimming, etc. SPACE CONTROLLED Daylightin` INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 10 161 PORTABLE LIGHTING (From LTG -3-C) 87 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 10,248 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING.METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 10,248 �X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE Check if tOTEa[,Ot Room # IDENTIFICATION Auto Time Switch, Dimming, etc. SPACE CONTROLLED Daylightin` CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1 -C ROJECT NAME 16N13/20 Calle Estado, LLC 07 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed BY: ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page: 13 of 102 1 CERTIFICATE OF COMPLIANCE MECH-1-C NAME Calle Estado, LLC 6/13/2007 ,)eslgner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required So check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratina and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that an; installed at the factory and certified with the commission do not require equipment testing but do require construction Inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required if the unit'serves 5,000 R2 of space or less and 25% or more of the ducts arein noncondiuoned or semicondiuoned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace duds or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls Installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than orequal to 500,000 Btufhr. -Water-loop Heat Pump Controls Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable now chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. -Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:14 0f 102 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C JPROJECT NAME DATE Calle Estado, LLC 6/13/2007 - INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description CD c w c 3.3 3 9 c y`�m m `� my � m� .0 ,y .. c 3.m 3 3�c d m m `� c 3v � oma' y m f° 0 M 0 mm c_0 �' r C Z 3. c 503 d c y mm x—�v�,ro n Metallux 2G-3-32ED F32T8 3 32 1.5 93.0 X 105 9.765 Metallux 6313 1 30 1.0 29.0 X 4 116 Portfolio C6032 FTR32WGX24 -3 1 32 1.0 35.0 X 8 280 PAGE TOTAL 10 161 BUILDING TOTAL (sum of all pages) 10,161 PORTABLE LIGHTING (From LTG -3-C) 87 CONTROL CREDIT (From LTG -4-C) D ADJUSTED ACTUAL WATTS 10 248 I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:15 of 102 1 PORTABLE LIGHTING WORKSHEET LTG -3 - ECT NAME Calle Estado, LLC DATE 6/13/2007 [TABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET I A B C D ROOM # DEFAULT OR ZONE ID W/s ft AREA TOTAL WATTS SF B X C Suite 102 0.2 433 87 ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. TASK # OF WATTS PER AREA TASK FIXTURE (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 104 484 1 484 Suite 105 TOTAL 433 87 TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B BUILDING TOTAL C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. TASK # OF WATTS PER AREA TASK FIXTURE (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 104 484 1 484 Suite 105 1 433 1 433 Suite 106 578 1 578 -cite 107 405 1 405 :iuite 201 I 619 1 619 Suite 202 728 1 728 Suite 203 1 781 1 781 Suite 204 860 1 860 TOTAL 4.888 0 Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TOTAL 7,744 87 I EnergvPro 4.3 by EnergvSoft User Number: 6712 Job Number: Page: 16 of 102 1 PORTABLE LIGHTING WORKSHEET LTG -3-C ECT NAME Calle Estado, LLC DATE 3/2007 ITABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET I A B C D ROOM # OR ZONE ID DEFAULT W/s ft AREA TOTAL WATTS SF B X C G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 205 1,733 1 1,733 Suite 206 690 1 690 TOTAL 0 0 TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B 7,744 C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 205 1,733 1 1,733 Suite 206 690 1 690 TOTAL 2.423 0 ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details Include luminaire types and mounting locations relative to work areas. 0 BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TOTAL 7,744 87 I EnergyPro 4.3 by EneravSoft User Number: 6712 Job Number: Paae:17 of 102 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C ECT NAME Calle Estado, LLC FEA ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation juct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. DATE 6/13/2007 AIR SYSTEMS, Central or Single Zone HVAC -4 HVAC -2 HVAC -2.5 1 1 1 Reference on Plans or Specification t 112(a) 8.60 HSPF 7.50 HSPF 7.70 HSPF 112(a) 12.5 SEER / 10.8 EER 12.5 SEER / 10.9 EER 12.3 SEER / 10.7 EER 112(b) Yes Yes Yes 112(c), 115(a),n/a 29,312 btuh n/a n/a 121(b) Yes Yes Yes 121 b 123 cfm 108 cfm 121 cfm 121 c No No No 121 c) Yes Yes Yes 121(c), 122(e) Pro rammable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Coolinq Required Heating & Cooling Require 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 1 R-4.2 I R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 29,355 btuh 14,990 btuh 18,737 btuh 144 a & b n/a n/a n/a 144 a & b 29,312 btuh 17,616 btuh 21,538 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c) 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No Run Initiation Time: 06113/07 13:ZU:1U Kun Gode: 1181766010 EnergyPro 4.3 by EnergvSoft User Number. 6712 Job Number: Page:18 of 102 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE 1 Calle Estado, LLC 6/13/2007 ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation �uct Insulation PRESCRIPTIVE MEASURES _Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS, Central or Single Zone HVAC -2 HVAC -2 HVAC 2.5 1 1 1 Reference on Plans or Specification 1 112(a) 7.50 HSPF 7.50 HSPF 7.70 HSPF 112(a) 12.5 SEER / 10.9 EER 12.5 SEER / 10.9 EER 12.3 SEER / 10.7 EER 112(b) Yes Yes Yes 112(c), 115(a),n/a 18,790 btuh n/a n/a 121(b) Yes Yes Yes 121 b 121 cfm 108 cfm 144 cfm 121 c No No No 121 c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Require 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 14,990 btuh 14,990 btuh 18,737 btuh 144 a & b n/a n/a n/a 144 a & b 18,790 btuh 18,760 btuh 22,916 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NIX in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. Kun initiation I Ime: utijim/ 13:zuou Kun Loocie: 11517661 iu EnergyPro 4.3 by EnergvSoR User Number. 6712 Job Number: Paae:19 of 102 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME s 1 Calle Estado, LLC ♦SYSTEM FEATURES DATE 6/13/2007 AIR SYSTEMS, Central or Single Zone 7.50 HSPF 7.10 HSPF 7.10 HSPF 1 1 1 ITEM OR SYSTEM TAG(S) HVAC 2 HVAC -3 HVAC -3 Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification' Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation )uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 7.50 HSPF 7.10 HSPF 7.10 HSPF 112(a) 12.5 SEER / 10.9 EER 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 112(b) Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121(b) 101 cfm 155 cfm 182 cfm 121 c No No No 121(c) Yes Yes Yes 121(c), 122(e) Pro rammable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 14,990 btuh 21,860 btuh 21,860 btuh 144 a & b n/a n/a n/a 144 a & b 18,765 btuh 26,872 btuh 26,916 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. MR SYSTEM REQUIREMENTS Part 1 Of 2 MECH-2-C ECT NAME Calle Estado, LLC ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation >uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. DATE 6/13/2007 AIR SYSTEMS Central or Single Zone HVAC -3 HVAC -4 HVAC -4 1 1 2 Reference on Plans or Specification 1 112(a) 7.10 HSPF 7.20 HSPF 7.20 HSPF 112(a) 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 112(b) Yes Yes Yes 112(c), 115(a).n/a 27,047 btuh n/a n/a 121(b) Yes Yes Yes 121 b 195 cfm 215 cfm 433 cfm 121 c No No No 121 c Yes Yes Yes 121(c), 122(e) Pro rammable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-4.2 R-4.2 R4.2 144 a & b n/a n/a n/a 144 a & b 21,860 btuh 29,355 btuh 58,710 btuh 144 a & b n/a n/a n/a 144 a & b 27,047 btuh 37,514 btuh 74,956 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No .11%J 1 CJ 1 V IGLU ' vul OUIIU 111 UC dl UIICIIL u5C Vlll .. r .. ... :.. t EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page:21 of 102 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C _PROJECT NAME r6/13/2007 AIR SYSTEMS, Central or Single Zone ITEM OR SYSTEM TAG(S) HVAC -3.5 Number of Systems 1 T-24 MANDATORY MEASURES Section Reference on Plans or Specification Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation f ,juct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 7.20 HSPF 112(a) 12.0 SEER / 10.4 EER 112(b) Yes 112(c), 115(a). n/a 121(b) Yes 121 b 172 cfm 121 c No 121 c Yes 121 c 122(e) Pro rammable Switch 122(e) Heating & Cooling Required 122 Auto 122(g) n/a 123 124 R-4.2 144 a & b n/a 144 a & b 25,607 btuh 144 a & b n/a 144 a & b 32,259 btuh 144 c Constant Volume 144 c 144 c Yes 144 d No 144 a No Economizer 144 Constant Tem 144 (f) Constant Temp 144 k No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/K in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. 1 _ 141in lniTmtrr%n 11m C• ni4ir9-4In7 9-4•711•'111 Wiln (:Arlo• 99R97arn9n 1 Energypro 4.3 by EnergySoft User Number: 6712 Job Number: Page:22 of 102 1 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C PROJECT NAME DATE . Calle Estado, LLC 6/13/2007 ITEM OR SYSTEM TAG(S) Number of Systems 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NIA" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification T-24 MANDATORY MEASURES Section Reference on Plans or Specification' Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES 114 b) Calculated Capacity 144 (a & b) Spa Heater - No Pilot Light 115 d Proposed Capacity 144 (a & b) Tower Fan Controls 144 h Tower Flow Controls 144 h Variable Flow System Design 144 Q) Chiller and Boiler Isolation 144 ' CHW and HHW Reset Controls 144 0) WLHP Isolation Valves 144 ' VSD on CHW, CW & WLHP Pumps > 5 144 HP DP Sensor Location 144 (p 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NIA" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification 113 (a) Water Heater Efficiency 113 b) Service Water Heating Installation 113 (c) Pool and Spa Efficiency and Control 114 a Pool and Spa Installation 114 b) Pool Heater - No Pilot Light 115 (c) Spa Heater - No Pilot Light 115 d AO SMITH ELJF-10 n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. rur LJUJIU!+c a1 unc ! uac vnl _ t ' y Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:23 of 102 MECHANICAL VENTILATION MECH-3-C ROJECT NAME Calle Estado, LLC DATE 6/13/2007 PRESCRIPTIVE REHEAT LIMITATION Section 144(d MECHANICAL VENTILATION Section 121 (b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E I F I G H I J K L I M N ZONEISYSTEM o D= TAO. to N C 2).00 W rDT TD'S c3 W�� X Dn 03-n v °1 3 -oc ro3 �rT �� 0 v road UI1T 3 7 c 09 m„= XC1 -n r- v 3 v3m y1O OX t 47°< D mo 0(1) T»N 3y'� N o 0` 04)0 TN gD� O TW 3 yX �A x n �E3 wgflr 07X n=om -n`to eco »� D vii D Suite 101 82C 0.151 123 1 123 1231 1 HVAC -4 Total 1 123 123 Suite 102 432 0.15 65 65 108 HVAC -2 Total 65 108 Suite 103 484 0.151 73 73 121 HVAC -2.5 Total 73 121 Suite 104 484 0.15 73 73 121 HVAC -2 Total 73 121 Suite 105 433 0.15 65 65 108 HVAC -2 Total 65 108 Suite 106 57E 0.15 87 87 144 )VAC 2.5 Total 87 144 uite 107 40q 0.15 61 61 101 HVAC 2 1 1 Total 61 101 Suite 201 61E 0.15 93 1 93 ' 155 HVAC -3 I I Total 93 155 Suite 202 72E 0.15 109 109 182 HVAC -3 Total 109 182 Suite 203 78 0.15 117 117 195 HVAC -3 Total 117 195 uite 204 86C 0.15 129 129 215 HVAC -4 Total 129 215 Suite 205 1,73 0.15260 260 433 HVAC -4 Total 260 433 Suite 206 69 0.15 104 104 172 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seal or the greater of the expected number of occupants and 50% of the CBC occupant load for eciress purposes fors ares without Posed seating. H Required Ventilation Air REQ'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be nreater than orequal to H or use Transfer Air column N to make up the difference. J Design fan su ly dm Fan CFM x 30%; or K Condition area Qt. sq.) x 04 cfmft sq.; or L Maximum of Columns H, J, K or 300 cfm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 24 of 102 MECHANICAL VENTILATION MECH-3-C NAME Calle Estado, LLC DATE 6/13/2007 PRESCRIPTIVE REHEAT LIMITATION (Section 144 d MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM C N�7Q -ntD :.' y7 N C '� N 1D 0�3 o O'E W D7 �d3 -UC C 3 aS �0 0 - '� T N N 3�3 Q mO7 X n `10rz i.. m 0 IN !� X O ��� D G T j Iy�D N CD3 NO 3 -n 0„ T f/1 30 � � T W aA P T`� O, C W a d C (n X T=o g� M NN• to -7 2� D � y -* D HVAC -3.5 Total 104 172 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces vdthout fixed seating. H Required Ventilation Air REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area(ft. sq.) x 04 cfmft sq.; or L Maximum of Columns H. J, K, or 300 cfm - M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 25 of 102 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C� PROJECT NAME _ _ DATE � „ - ,---_ R ANI'] TQWFR SUMMARY CENTRAL SYSTEM RATINGS Efficiency Tons PUMPS System Name System Type Equipment Name Equipment Type qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 2 5,120 10 New 0.95 n/a n/a 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 0.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 21 30,000 0.0 7.70 HSPF 28,600 MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Carrier 50JX0365 Control # HP Type In Plenum Outside DHW BOILER SUMMARY CENTRAL SYSTEM RATINGS Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. O SMITH ELJF-10 Small Elec. All Pipes Ins 2 5,120 10 New 0.95 n/a n/a 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 0.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 21 30,000 0.0 7.70 HSPF 28,600 MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Carrier 50JX0365 Control # HP Type In Plenum Outside Buried Add 1/2" Insulation No Economizer Carrier 50JX0485 Packaged DX 3 47,000 0.0 7.20 HSPF 48,000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0423 Packaged DX 1 41,000 0.0 7.20 HSPF 41,500 12.0 SEER / 10.4 EER New No Economizer CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type output Aux. I kW Eff. output Efficiency Condition Status Economizer Type Carrier 38YRA04833 Split DX 1 47,000 0.0 8.60 HSPF 47,500 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 0.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 21 30,000 0.0 7.70 HSPF 28,600 12.3 SEER / 10.7 EER New No Economizer Carrier 50JX0365 Packaged DX 3 35,000 0.0 7.10 HSPF 35 000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0485 Packaged DX 3 47,000 0.0 7.20 HSPF 48,000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0423 Packaged DX 1 41,000 0.0 7.20 HSPF 41,500 12.0 SEER / 10.4 EER New No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN S stem Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 38YRA04833 Constant Volume Draw -Through 1,600 0.50 76.0% 97.0% none Carrier 38YRA02433 Constant Volume Draw -Through 8001 0.25 64.0% 97.0% none Carrier 38YRA03033 Constant Volume Draw -Through 1,000 0.33 64.0% 97.0% none Carrier 50JX0365 Constant Volume Blow -Through 1,200 0.33 64.0% 97.0% none Carrier 50JX0485 Constant Volume Blow -Through 1,600 0.50 76.0% 97.0% none Carrier 50JX0423 Constant Volume Blow -Through 1,4001 0.50 76.0%1 97,0%1 none Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 Energ ro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 26 of 102 ENVELOPE MANDATORY MEASURES ENV -MM ROJECT NAME Calle Estado. LLC DATE 6/13/2007 DESCRIPTION Desi ner Enforcement _ ❑X § 118(,) Installed Insulating Material shall have been certlfied by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. FXJ§ 118(c) All Insulating Materials shall be Installed In compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X❑ § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. §`116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(,)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured l fenestration products must be labeled for U -value according to NFRC procedures. X❑ §118(,) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: Page:27 of 102 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C PROJECT NAME Calle Estado, LLC FOR'ENEORCEtIhENT AGENCY; USE ONLY CUMENTATION AUTHOR DATE //�� PLAN CHECK 6i DATE /�sK. ANGULAR SPACES A B C D E F Room Name Task/Activity Description Room Length (L) ft Room Width (W) ft Room Cavity Height (H) (ft) Room Cay. Ratio 5xHx(L+W) /(LxW) A B C D E F Room Name Task/Activity Description Room Area (A) (so Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A 4.3 by EnergySoft User Number: 6712 Job Number: Page:28 of 102 CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C PROJECT NAME DATE Calle Estado, LLC 6/13/2007 ?ROJECT ADDRESS _.-`'�r'i_ Desert Club Dr. & Calle Estado La Quinta' PRINCIPAL DESIGNER - LIGHTING TELEPHONE Hegge Electrical Contractors (760) 775-48551: DOCUMENTATION AUTHOR TELEPHONE OCR! r Gheckec by/D! Scott Design & Title 24 (760) 200-4780 y� Enfotgem2nt'A9en t1ei ;t, GENERAL INFORMATION DATE OF PLANS OUTDOOR LIGHTING ZONE LZ1 LZ2 ❑X LZ3 LZ4 FUNCTION TYPE 0 OUTDOOR LIGHTING OUTDOOR SIGNS F-1 INDOOR SIGNS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION F7-1 ADDITION F-1 ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE Tim Scott The Principal Lighting Designer hereby certifies that the proposed outdoor lighting and signs design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146,and 149 of Title 24, Part 6. )lease Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME DATE LIC. # 7SIGNATURE He a Electrical Contractors LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®OLTG-1-C: Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 maybe incorporated in schedules on the p Either LTG -1-C or OLTG-I-C may be used for signs as follows: 1. Use LTG -1-C if the project consists solely of indoor signs. 2. Use LTG -1-C if the project consists of indoor lighting, outdoor or indoor signs, but no other outdoor lighting. 3. Use OLTG-1-C if the project consists solely of outdoor signs. 4. Use OLTG-I-C if the project consists of outdoor lighting, outdoor or indoor signs, but no other indoor lighting. Ox OLTG-2-C: LIGHTING COMPLIANCE SUMMARY. Applicable parts required for ALL outdoor lighting allowances (Except Signs). OLTG-3-C: AREA CALCULATIONS WORKSHEET. Applicable parts required for all outdoor area calculations. OOLTG-4-C: SIGN LIGHTING COMPLIANCE. Required for all internally and externally illuminated signs, for both indoor and outdoor signs. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:29 of 102 ans. CERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-1-C NAME Calle Estado, LLC S h d 1 PI Sh th t 0 td L' ht' t All wed Li hY P u nun C e U eS On anS OW a U OOr I IM DATE 6/13/2007 n ee S O In v.vc, ❑ Lighting power allowance for general site illumination on OLTG-2-C Part 1 of 4 ❑X Not Applicable ❑ ❑X Lighting power allowance for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4 Not Applicable ❑X ❑ Lighting power allowances for specific applications, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4 Not Applicable ❑ - Lighting power allowances for vehicle service station canopies on OLTG-2-C part 4 of 4 ❑R Not Applicable ❑ ❑X Sign lighting compliance on OLTG-4-C Not Applicable Mandatory Measures on Plans Show that Outdoor Lightina Meets Outdoor Lightina Controls And Eauipment X❑ ❑ Installed lighting power has been determined in accordance with Section 130(c)1 Not Applicable ❑X ❑ All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumins per Watt or are controlled by a motion sensor per Section 132(a) Not Applicable ❑X All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements of Section 132(b) Not Applicable ❑X ❑ All permanently Installed outdoor lighting meets the control requirements of Section 132(c)1 Not Applicable ❑X ❑ Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements of Section 132(c) Not Applicable MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION Room # ( ) FIOTEktTO} - ,F;:;FIELp�;, CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) AREA CONTROLLED EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 30 of 102 LIGHTING COMPLIANCE SUMMARY (Part 3 of 4) OLTG-2-C I � (,Project Name Date Calle Estado, LLC 6/13/2007 LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS able 147-B - Other than Vehicle Station without Canopies Allotted Watts Luminalre Lam s/Ballasts Desl n Watts A B C D E F G H I J K I L IM N O P Lighting Application Category (Table 147-B) ra° °�' T ,! rLr"�° ; U) CL '^ c r� p y ° �(D a n Fo c a ° Description T. �° c ' r ,gym v3 ° v ° °' 39 341 >v. m rm m 3 v ID c a 3d �,y. �. m c 3 �. m :z m n v c 3 �Q mm c X Er ? ID D 3� °,° va o O Ext Task 1,87 0.35 655 50w Low Voltage Halogen 50 Watt 1 50 1.0 54.0 X 8 43 43 Ext Task 27 38.50 10,626 50w Low Voltage Halogen Matt 1 50 1.0 54.0 X 18 97 97 Lamp I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:31 of 102 1 ILLUMINATED AREA CALCULATION WORKSHEET (Part 3 of 5) OLTG-3-C PROJECT NAME Calle Estado, LLC t. Outdoor Sales Lot Frontage and Sales Lot Area DATE 6/13/2007 A B C I D E I F G H = Gross Illuminated Area (sq. ft.) If an Outdoor Sales Frontage Allotment was used, subtract that area from the Gross Illuminated Area Overlapping Areas of Another Application Sales Lot Area (A - F - G) Mounting height of Sales Frontage Luminaires (feet) 3 x B Distance (In plan view) from the frontagge luminaire to fron edge of Sales Lot Sales Lot Frontage Length (feet) Sales Frontage Area (C - D) x E (sq. ft.) Area for which Illumination is Net Area Designated Name and Orientation Length Height Gross Area (B x C) Areas covered by signs Obstructed by Other Objects and Area Not Illuminated Sub totalLigghtin (E + F) Available for Facade (D -G � Ext Task 156 12 1.872 0 0 1,872 ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. LJ Section 147 (c)2 B - Measured in plan view, only illuminated sections of outdoor sales frontage areas that are immediately adjacent to the principle viewing location and unobstructed viewing length, and are within 3 mounting heights of the frontage have been used. Luminaires qualifying for this allowance are located in plan view between the principle viewing location and the frontage sales. A B C D E I F I G H Areas (SF) to Subtract from within the Illuminated Area Area for which Illumination is Net Area Designated Name and Orientation Length Height Gross Area (B x C) Areas covered by signs Obstructed by Other Objects and Area Not Illuminated Sub totalLigghtin (E + F) Available for Facade (D -G � Ext Task 156 12 1.872 0 0 1,872 - . Checklist ❑Section 147 (c)1 B -Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. Section 147 (c)2 A - Only facades areas that are illuminated without obstruction or interference, by one or more luminaires, have been used. 1 EnergvPro 4.3 by EnergySoft User Number: 6712 Job Number: Pace: 32 of 1102 1 LIGHTING MANDATORY MEASURES LTG -MM NAME Calle Estado, LLC DATE 6/13/2007 DESCRIPTION Designer Enforcement X] §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. FX §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X] §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. X❑ §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. X❑ §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:33 of 102 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM ROJECT NAME Calle Estado, LLC DATE 6/13/2007 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. 0 § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: 0 § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power Is interrupted; or - § 122(e)1 B An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a8,b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. RX § 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: Page: 34 of 102 MECHANICAL MANDATORY MEASURES Part2 of 2 MECH-MM __IPROJECT NAME DATE ) Calle Estado, LLC 1 6/13/2007 Description Designer Enforcement Ventilation ❑X § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 1220 Gravity or automatic dampers Interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. a§ 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ § 121(01 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or F§ 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or. § 121(f)4 Another method approved by the Commission. Service Water Heating Systems ❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. X] §m(c) Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number. User Job Number: Page: 35 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Calle Estado LLC 6/13/2007 YSTEM NAME FLOOR AREA HVAC -4 820 Outside Air (%) COIL HTG. PEAK 7.7 Outside Air (cfm/sgft) CFM 0.15 Note: values above (EATING SYSTE 26.0 of Outside Air 123 cfm 69.6 OF at ARI conditions YCHROMETRICS 66.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,613 22,363 3,743 1,097 15,174 0 1,118 759 0 0 123 4,888 1,052 123 5,70 0 0 1,118 759 29,488F 4 795 22 392 Carrier 38YRA04833 29,312 13,743 29,355 Total Adjusted System Output28,312 13,743 29,355 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Heating Coil 83.4 of 83.4 of Supply Air Ducts s A! Supply Fan 83.0 of 1600 cfm ROOMS 70.0 of Return Air Ducts I (COOLING_ SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 112.0 / 77.9 of ">. I Outside Air 123 cfm 174.7 / 65.0 OF 77.5 / 66.2 of ® 60.3 / 59.4 of Cooling Coil Supply Fa 1600 cfm 60.3 / 59.4 of -� Supply Air Ducts Fan 61.0/59.7OF 61.6% R.H. ROOMS 74.0/64.8OF �i Return Air Ducts 4 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paae:36 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC ;(STEM NAME HVAC -2 Number of Systems . 1 Heating System Output per System 24,000 Total Output (Btuh) 24,000 Output (Btuh/sgft) 55.4 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 55.4 Total Output (sgft/Ton) 216.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfmisqft) 1.85 Airflow (cfm/Ton) 400.0 Outside Air (%) 13.5 Outside Air (cfm/sqft) 0.25 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 433 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 836 12,608 1,977 609 7,052 0 630 353 0 0 108 4,292 1,215 108 5,02 0 0 630 353 18 162 37191 12,7791 Carrier 38YRA02433 17,616 4,197 14,990 Total Adjusted System Output17,616 4,197 14,990 (Adjusted for Peak Design Conditions) --- TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 63.7 OF 81.3 OF 81.3 °F Supply Air Ducts Outside Air 108 cfm H" o Heating Coil Supply Fan 80.9 F 800 cfm ROOMS 69.6 OF 70.0 OF Return Air Ducts I 112.0 / 77.9 OF Outside Air 108 cfm 74.7/64.3 of EneravPro 4.3 PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 79.8 / 66.4 OF ® 59.1 / 58.0 OF 59.1 / 58.0 OF User Number: 6712 Cooling Coil Supply Air Ducts Supply Fan 59.8 / 58.3 OF 800 cfm 58.6% R.H. rROOMS 74.0 / 64.0 OF Return Air Ducts Job Number. Page:37 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC (STEM NAME I HVAC -2.5 Outside Air COIL HTG. PEAK 12.1 I Sensiblel Latent CFM ri Note: values above given at ARI conditions 11-IEATING SYSTEM PSYCHROMETRICS (Airs1 26.0 OF Outside �� 121 cfm 69.5 of 112.0 / 77.9 OF ON Outside Air 121 cfm 74.8/64.2 of EneravPro 4.3 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 484 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,196 17,886 2,209 924 11,115 0 894 556 0 0 12 4,785 1,382 121 5,599 0 0 894 556 24,4651 3=592 17 825 Carrier 38YRA03033 21,538 4,356 18,737 Total Adjusted System Output 21,538 4,356 18,737 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am 64.2 OF r7 81.8 °F W= Heating Coil airstream 7 79.3 / 66.2 of User Number: 6712 Supply Fan 1000 cfm seating vem 81.8 OF -� Supply Air Ducts 81.3 OF ROOMS 70.0 OF )% Return Air Ducts `i watures at Time of Cooling Peak) 59.1 / 58.0 OF 59.1 / 58.0 OF Supply Air Ducts �-�- PP Y Supply Fan 59.9 / 58.4 OF 1000 cfm 58.4% R.H. ROOMS 74.0 / 64.0 of Cooling Coil h Return Air Ducts 'I Job Number: 38 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC STEM NAME HVAC -2 (Number of Svstems 1 11 24 Total Cooling System Output per System 2 Total Output (Btuh) 2 Total Output (Tons) Total Output (Btuhlsgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfmisgft) Airflow (cfmlTon) t } Outside Air (%) Outside Air (cfm/sgft) f Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 62.9 of Outside Air 121 cfm 69.4 of COOLING S 112.0 / 77.9 of Outside �� 121 cfm 78.7/66.8 of ,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts ,000 49.6 I I CFM ,000 ,000 2.0 49.6 1I TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 484 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 759 12,567 1,957 917 9,662 0 628 483 0 0 12 4,283 833 121 5,593 0 0 628 483 18,107F 7791 16 22 ouu 800 Carrier 38YRA02433 18,790 3,870 14,990 1.65 400.0 15.1 Total Adjusted System Output 18 790 3,870 14,990 (Adjusted for Peak Design Conditions) 0.25 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Heating Coil 80.5 of res at Time of Supply Fan 800 cfm 80.5 of Supply Air Ducts 79.9 of ROOMS 70.0 of k Return Air Ducts 4 airstream Temperatures at 83.8/68.7OF 61.7/60.5°F Is Cooling Coil Supply Fa 800 cfm 61.7 160.5 of -> Supply Air Ducts Fan 62.4 / 60.7 of 55.6% R.H. ROOMS 78.0 / 66.6 of Return Air Ducts `S I. EnergvPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:39 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 1. Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 63.7 of Outside Air 108 cfm ROJECT NAME Calle Estado, LLC (STEM NAME HVAC -2 Number of Systems 1 Heating System Output per System 24,000 Total Output (Btuh) 24,000 Output (Btuh/sgft) 55.4 Cooling System Output per System 24,000 Total Output (Btuh) 24,000' Total Output (Tons) 2.0 Total Output (Btuh/sgft) 55.4 Total Output (sgft/Ton) 216.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.85 Airflow (cfm/Ton) 400.0 Outside Air (%) 13.5 Outside Air (cfm/sgft) 0.25 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 433 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 628 10,857 1,75 607 7,030 0 543 352 0 0 108 3,843 89511 108 5,02 0 0 543 352 15 786 2,6461 12 754 Carrier 38YRA02433 18,760 3,696 14,990 Total Adjusted System Output 18,760 3,696 14,990 am (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 tream Temperatures at Time of Heating Peak) 81.3 OF 81.3 of UA -� Supply Air Ducts 3 Heating Coil Supply Fan 80'9 OF 800 cfm ROOMS 69.6 OF 70.0 of _ I COOLING SYSTEM P 112.0 / 77.9 of Outside Air 108 cfm 78.6/66.4 0 EnerovPro 4.3 Return Air Ducts irstream Temperatures at Time of Cc 83.2/68.10F ® 61.1/59.90F 61.1 / 59.9 of User Number: 6712 Cooling Coil Supply Fa 800 cfm Fan -), Supply Air Ducts 61.8/60.1°F 54.2% R.H. ROOMS 78.0 66.2 OF Return Air Duct I Job Number: of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ROJECT NAME Calle Estado, LLC !STEM NAME HVAC 2.5 Number of Systems 1 Heating System Output per System 30,000 Total Output (Btuh) 30,000 Output (Btuh/sgft) 51.9 Cooling System Output per System 28,600 Total Output (Btuh) 28,600 Total Output (Tons) 2.4 Total Output (Btuh/sgft) 49.5 Total Output (sgft/Ton) 242.5 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.73 Airflow (cfm/Ton) 419.6 Outside Air (%) 14.4 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRI 26.0 OF Outside �� 144 cfm 69.6 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 578 COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent J, CFM I Sensible 72 11,955 2,337 695 7,82 0 598 39 0 0 144 5,142 953 144 6,710 0 0 598 391 18,299T 3 290 F77;;313 Carrier 38YRA03033 22,916 4,064 18,737 Total Adjusted System Output 22 916 4,064 18,737 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am 63.3 OF ifl 80.9 OF Heating Coil Supply Fan 1000 cfm 80.9 OF —> Supply Air Ducts 80.6 OF ROOMS 70.0 OF �% Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0 / 77.9 OF 83.4 / 68.6 OF 61.9 ! 60.6 OF 61.9 60.6 OF a t'Y Supply Air Ducts Outside Air 144 cfm Cooling Coil Supply Fan 62.4 / 60.8 OF 1000 cfm 55.9% R.H. ROOMS 78.6/66.90F 78.0/66.7°F 4.3 User Number: 6712 Return Air Ducts Job Number: of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY " PROJECT NAME - P Calle Estado, LLC )STEM NAME HVAC 2 EATING SYSTEM 26.0 OF Ouits�i'de 101 cfm 69.6 OF TOOLING SYSTEM PSYCH 12.0 / 77.9 OF Outside Air 101 cfm 78.6/66.2 °F - i 4.3 RICS 64.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 405 COIL COOLING PEAK 11COILHTG.PEAK CFMISensiblel Latent 11CFM1Sensible 60 10,595 1,638 632 7,534 0 530 377 0 0 10 3,597 91 101 4,693 0 0 530 377 15,2J 2 549 12 98 Carrier 38YRA02433 18,765 3,583 14,990 Total Adjusted System Output 18,765 3,583 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am earn Temperatures at Time of Heating Peak) 81.7 OF 81.7 OF �� Heating Coil Supply Fan 800 cfm Supply Air Ducts 81.2 OF ROOMS 70.0 OF Return Air Ducts I 82.8 / 67.9 OF 60.8 ! 59.6 OF Cooling Coil Supply Fa 800 cfm User Number: 6712 60.8 / 59.6 of Supply Air Ducts Fan 61.4/59.8OF 53.5% R.H. ROOMS 78.0/66.0°F Return Air Ducts Job Number: 42 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (NAME Calle Estado, LLC NAME HVAC -3 lNumber of Systems 1 11 Heating System output per System 35,000 Total Output (Btuh) 35,000 Outout (Btuh/sgft) 56.5 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 56.5 Total Output (sgft/Ton) 212.2 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.94 Airflow (cfm/Ton) 411.4 } Outside Air (%) 12.9 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 64.0 OF 64.0 OF �V.� Outside Air U. 155 cfm 69.6 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 619 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM FSensible 1,102 17,990 2,503 905 10,292 0 83.0 / 68.5 of 83.0 / 68.5 OF 899 515 0 0 155 5,483 1,02 155 7,180 0 �r 0 899 515 25,277 3,524 F 18,501 Carrier 50JX0365 26,872 6,066 21,860 Total Adjusted System Output 26,872 6,066 21,860 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am earn Temperatures at Time of Heatina Peak) Supply Fan Heating Coil 1200 cfm �% Return Air Ducts 4 Supply Air Ducts 80.7 OF ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0 / 77.9 OF 83.0 / 68.5 of 83.0 / 68.5 OF 62.0 60.8 OF Supply Air Ducts Outside Air �r 155 cfm Supply Fan Cooling Coil 62.7 / 61.0 OF 1200 cfm ROOMS 55.9% R.H. 78.7/66.9 °F 78.0 / 66.7 OF Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:43 of 102 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Calle Estado, LLC 6/13/2007 . STEM NAME FLOOR AREA HVAC -3 728 ENGINEERING CHECKS SYSTEM LOAD F Note: values above given at ARI conditions Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sqft) 48.1 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuhlsgft) 48.1 Total Output (sgft/Ton) 249.6 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.65 Airflow (cfmlTon) 411.4 Outside Air 26.0 OF Outside Air 182 cfm 69.6 of 63.0 OF 63.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 837 48 0 0 182 6,458 888 182 8,449 0 0 837 481 (%) 15.2 Outside Air (cfmisgft) 0.25 F Note: values above given at ARI conditions Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sqft) 48.1 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuhlsgft) 48.1 Total Output (sgft/Ton) 249.6 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.65 Airflow (cfmlTon) 411.4 Outside Air 26.0 OF Outside Air 182 cfm 69.6 of 63.0 OF 63.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 1,070 16,748 2,944 928 9,629 0 837 48 0 0 182 6,458 888 182 8,449 0 0 837 481 24,8d 3,8J 19 04 HVAC EQUIPMENT SELECTION Carrier 50JX0365 26,916 6,382 21,860 Total Adjusted System Output 26,916 6,382 21,860 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am rstream Tei i Supply Fan Heating Coil 1200 cfm C3 -1 -- Supply Air Ducts 79.7 OF ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.9°F 83.7/69.1OF 83.7/69.1°F 62.6/61.4°F Supply Air Ducts Outside Air 182 cfm Supply Fan Cooling Coil 63.3 / 61.7 of 1200 cfm 57.6% R.H. ROOMS 78.7/67.4 of 78.0 / 67.2 of Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:44 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY NAME Calle Estado, LLC NAME HVAC -3 [Number of Systems 1 11 Total Output (Btuh) s Output(Btuh/sgft) Cooling System Output per System 3 Total Output (Btuh) 3 Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Alrflow (cfm/Ton) > Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0 OF 62.4 OF 62.4 OF Outside Air .W. 195 cfm 69.5 OF OOLING SYSTEM 12.0 / 77.9 OF Outside Air 195 cfm 78.8 / 67.7 OF 4.3 5,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 5,000 44.8 Latent 5,000 5,000 2.9 44.8 267.8 614 0 1 HVAC EQUIPMENT SELE DATE 6/13/2007 FLOOR AREA 781 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM Sensible 1,408 21,167 3,158 1,271 12,278 0 1,058 614 0 0 195 6,893 760 195 9,043 0 0 1,058 614 30,1761 3,9181 F 22,5491 ,200 1,200 Carrier 50JX0365 27,047 6,468 21,860 1.54 411.4 16.3 Total Adjusted System Output 27,047 6,x68 21,860 (Adjusted for Peak Design Conditions) 0.25 TIME OF SYSTEM PEAK Jul 3 pm F Jan 12 am (Airstream Temperatures at Time of Heating Peak) im 79.6 OF Supply Fan Heating Coil 1200 cfm h Return Air Ducts 11 84.2/69.5 OF 84.2/69.5 OF ® 63.0/61.8 OF Supply Fan Cooling Coil 1200 cfm User Number: 6712 of Co Return Air Ducts Job Number. Supply Air Ducts 79.1 OF ROOMS 70.0 OF Supply Air Ducts 63.9 / 62.1 OF 58.6% R.H. ROOMS 78.0 / 67.5 OF 1 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC {STEM NAME I HVAC -4 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.86 Airflow (cfm/Ton) 400.0 Outside Air (%) 13.4 Outside Air (cfmisgft) 0.25 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airsi 26.0 of 63.8 of 63.8 of El 9.Im Outside Air 215 cfm` 69.6 of TOOLING SYSTEM PS 12.0 / 77.9 of Outside Air 215 cfm . 178.6 / 66.4 of S Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 860 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,223 21,219 3,477 1,145 12,939 0 1,061 647 0 0 215 7,637 1,796 215 9,98 0 0 1,061 1 647 30,978F 5-2741 24 214 Carrier 50JX0485 37,514 7,370 29,355 Total Adjusted System Output 37,514 7,370 29,355 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am earn Temneratures at Time of Heatina Peakl Supply Fan Heating Coil 1600 cfm ROMETRICS (A 83.1 / 68.1 of nri ZAt Supply Far 1600 cfm 81.0017 �% Return Air Ducts 4 R,A 1 / aft 1 OF ® a1 1 / 59 8 of 4.3 by EnergySoft User Number: 6712 Cooling Coil Supply Air Ducts 80.6 of ROOMS 70.0 of in Supply Air Ducts 61.7 / 60.1 of 54.1% R. H. ROOMS 78.0 66.2 of Return Air Ducts I Job Number: Page:46 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC ,STEM NAME - - HVAC -4 ENGINEERING CHECKS Number of Systems 2 Heating System Output per System 47,000 Total Output (Btuh) 94,000 Output (Btuh/sgft) 54.2 Cooling System Output per System 48,000 Total Output (Btuh) 96,000 Total Output (Tons) 8.0 Total Output (Btuh/sgft) 55.4 Total Output (sgft/Ton) 216.6 Air System CFM per System 1,600 Airflow (cfm) 3,200 Airflow (cfm/sqft) 1.85 Airflow (cfm/Ton) 400.0 (%) Outside Air ( Outside Air 13.5 CFM cfm/sgft) 0.25 I Sensible Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airst 1,901 26.0 OF 63.8 OF 63.8 OF 0 0 433 Outside Air 3,61 433 20,145 W433 0 cfm . 1,052 69.7 OF 12.0 / 77.9 OF > ;i Outside Air 433 cfm 78.6 / 66.4 OF 4.3 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 1.733 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 2,182 38,013 7,008 1,847 21,046 0 1,901 1,052 0 0 433 15,419 3,61 433 20,145 0 0 1,9011 1,052 57,233F 10,6181 43 295 arrier 50JX0485 74,956 14,815 58,710 Total Adjusted System Output 74,956 14,815 58,710 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm an 12 am am Temaeratures at Time of Heatina Peakl Supply Fan Heating Coil 3200 cfm 81.0 OF Return Air Ducts '-J 3s at Time of Coo 83.1 / 68.1 OF 83.1/68.10F ® 61.1/59.80F Supply Fan Cooling Coil 3200 cfm User Number. 6712 Return Air Ducts Job Number: Supply Air Ducts 80.7 OF ROOMS 70.0 OF Supply Air Ducts 61.6 / 60.0 OF 54.2% R.H. ROOMS 78.0/66.2 OF of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC STEM NAME I HVAC -3.5 4 Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airsl 26.0 of 64.2 of 64.2 of Outside Air 172 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 690 COIL COOLING PEAK 12.3 CFM 0.25 4 Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airsl 26.0 of 64.2 of 64.2 of Outside Air 172 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 690 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,348 22,915 2,790 L11194 12,869 0 1,146 643 0 0 172 6,097 1,415 172 7,998 0 0 1,146 1 643 31,367 4,205 22154 Carrier 50JX0423 32,259 6,511 25,607 Total Adjusted System Output 259 6,511 25,607 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am Supply Fan Heating Coil 1400 cfm Ai im Temperatures at 81.4 of h Return Air Ducts 4 12.0/77.9 OF 82.9/68.0 OF 82.9/68.10F ® 61.2/60.0 OF Outside Air �`�/J 172 cfm Supply Fan Cooling Coil 1400 cfm 78.8 / 66.5 of EnergyPro 4.3 User Number: 6712 Return Air Ducts Job Number: Supply Air Ducts 81.0 of ROOMS 70.0 of Supply AIr Ducts 62.0 / 60.3 of 54.3% R.H. ROOMS 78.0 / 66.2 of of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -4 FLOOR AREA 820 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 101 Suite 101 1 1,613 22,363 3,743 1,613 22,363 3,743 1,097 15,174 EnergyPro By EnergySoft User Number. User Job Number: Page -49 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC STEM NAME HVAC -2 DATE 6/13/2007 FLOOR AREA 433 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 102 Suite 102 1 836 12,608 1,977 836 12,608 1,977 609 7,052 l PAGE TOTAL 836 12,608 1,977 609 7,052 TOTAL 836 12,608 1,677 609 7,052 EnergyPro By EnergySoft User Number: User Job Number. Page:50 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -2.5 FLOOR AREA 484 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 103 Suite 103 1 1,199 17,938 2,211 1,196 17,886 2 209 924 11,115 PAGE TOTAL 1 1,196 17,886 2,209 924 11,115 TOTAL 1 1,196 17,886 2,209 924 11,115 EnergyPro By EnergySoft User Number. User Job Number: Pege:51 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC HVAC -2 DATE 6/13/2007 FLOOR AREA 484 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 104 Suite 104 1 759 12,567 1,957 759 12,567 1,957 917 9,662 1 PAGE TOTAL 759 12,567 1,957 917 9,662 ! TOTAL 759 12,567 1,957 917 9,662 EnergyPro By EnergySoft User Number: User Job Number: Page:52 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 ,(STEM NAME HVAC -2 FLOOR AREA 433 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 105 Suite 105 1 628 10,857 1,751 628 10,857 1 751 607 7,030 EnergyPro By EnergySoft User Number. User Job Number. Page:53 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC 2.5 FLOOR AREA 578 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 106 Suite 106 1 725 12,022 1,943 721 11,955 2,337 695 7,821 PAGE TOTAL 1 721 11,955 2,337 695 7,821 TOTAL 1 721 11,955 2,337 695 7,821 EnergyPro By EnergySoft User Number: User Job Number: Page:54 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC 2 FLOOR AREA 405 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Suite 107 Suite 107 1 601 10,595 1,638 601 10,595 .1,638 632 7,534 EnergyPro By EnergySoft User Number: User Job Number: Page:55 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 ;STEM NAME HVAC -3 FLOOR AREA 619 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 201 Suite 201 1 1,106 18,046 2,505 1,102 17,990 2.503 905 10,292 PAGE TOTAL L.1,1021 17,990 2,503 905 107292 TOTAL 1 1,102 17,990 2,503 905 10,292 EnergyPro By EnergySok User Number: User Job Number: Page:56 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 , STEM NAME HVAC -3 FLOOR AREA 728 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 202 Suite 202 1 1,070 16,748 2,944 1,070 16,748 2,944 928 9,629 EnergyPro By EnergySoft User Number: User Job Number: Page:57 of 102 ROOM LOAD SUMMARY ::1 PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -3 FLOOR AREA 781 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENTCFM SENSIBLE LATENT CFM SENSIBLE Suite 203 Suite 203 1 1,408 21,167 3,158 1,408 21,167 3,158 1,271 12,278 r� EnergyPro By EnergySoft User Number: User Job Number: Page: 58 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -4 FLOOR AREA 860 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 204 Suite 204 1 1,223 21,219 3,477 1,223 21,219 3,477 1,145 12,939 J EnergyPro By EnergySoft User Number: User Job Number. Page:59 of 102 ROOM LOAD SUMMARY ROJECT NAME Calle Estado, LLC DATE 6/13/2007 RSTEM NAME HVAC -4 FLOOR AREA 1,733 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 205 Suite 205 1 2,182 38,013 7,008 2,182 38,013 7,008 1,847 21,046 PAGE TOTAL 2,182 38,013 7,008 1,847 21,046 TOTAL 2,182 38,013 7,008 1,847 217046 EnergyPro By EnergySoft User Number: User Job Number: Page:60 of 102 ROOM LOAD SUMMARY 7 rNAME Calle Estado, LLC NAME HVAC -3.5 RQQM LOAD SUMMARY DATE 6/13/2007 FLOOR AREA 690 EnergyPro By EnergySoft User Number. User Job Number: Page:61 of 102 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 206 Suite 206 1 1,385 23,555 2,079 1,348 22,915 2,790 1 104 12,869 PAGE TOTAL 1 1,348 22,915 2,790 1,104 12,869 TOTAL 1 1,348 22,915 2,790 1,104 127869 EnergyPro By EnergySoft User Number. User Job Number: Page:61 of 102 ROOM HEATING PEAK LOADS PZect Title Date ile Estado LLC 16/13/2007 Room Information Desian Conditions Room Name Suite 101 Time of Peak Jan 12 am Floor Area 820 Outdoor Dry Bulb Temperature 26°P Indoor Dry Bulb Temperature 70°F Conduction Area U -Value 178.0 X X X X X x X X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x 0.0740 X X X X x X X X X X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x 24.0 0.5800 48.0 0.5800 24.0 0.5800 36.0 0.5800 64.0 0.0740 36.0 0.5800 164.0 0.0740 0 346.0 0.0740 20.0 0.5800 24.0 0.5800 15.0 0.0740 perimeter = 98.0 0.7300 i ,LT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room: Page Total: 11 974 Infiltration: r 1.00 1 X 1.064 X 820 X 10.00 X 0.500 / 60] X 44 = 3 200 schedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,174 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 62 of 102 ROOM HEATING PEAK LOADS Project TitleDate }aIle Estado, LLC 16/13/2007 Room Information Desicin Conditions Room Name Suite 102 Time of Peak .Ian 12 am Floor Area 433 Outdoor Dry Bulb Temperature 260 Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value R-19 Wall W.19.2x6-16 69.0 X X X X X X X X X. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0740 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x X X X x X X X X X Double Non Metal Tinted 24.0 0.5800 Double Non Metal Tinted 48.0 0.5800 Double Non Metal Tinted 24.0 0.5800 116.0 0.0740 Double Non Meta !Tinted 24.0 0.5800 Double Non Metal Tinted 25.0 0.5800 Slab -On -Grade perimeter = 33.0 0.7300 AT of Btu/hr 225 612 1,225 612 378 612 638 1,060 items snown with an astensK genote conauction through an interior surface to another room. Page Total: I 5.3631 Infiltration: r 1.001 X 1.064 X 433 X 10.00 X 0.500 / 6] X ® = 1 690 schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7 052 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:63 of 102 ROOM HEATING PEAK LOADS EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 64 of 102 Project Title `?aIle Estado, LLC Date 16/13/2007 Room Information Desi n Conditions Room Name Suite 103 Floor Area 484 Indoor Dry Bulb Temperature 70 OF Time of Peak .Ian 12 am Outdoor Dry Bulb Temperature 26 Conduction Area x X x x X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x U -Value X X X X X X X X X X x X x x x X x X x x x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = - = = = = = = = = = = = = = = = = = = = = = Btu/hr R-19 Wall .19.2x6.16 134.0 0.0740 44 436 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 Double Non Metal Tinted 24.0 0.5800 44 612 181.0 0.0740 44 589 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 25.0 0.5800 44 638 R-19 Wall .19.24.16 241.0 0.0740 44 785 240 1-4500 44 1.531 Slab -On -Grade perimeter = 68.0 0.7300 44 2,184 ` ) Items shown with an asterisk ('r) denote conduction through an interior Infiltration: 1.00 x 1.064 x -Schedule Air Sensible Fraction surface to another room. 484 x 10.00 Area Ceiling Height 0.500 / 60] ACH Page Total: 0 LT 9 226 1 889 TOTAL HOURLY HEAT LOSS FOR ROOM 11,115 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 64 of 102 ROOM HEATING PEAK LOADS Project Title Date ally Fctario I I C; IR/1 vqnu Room Information Desi - n Conditions Room Name Suite 104 Time of Peak Jan 12 am Floor Area 484 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction R-19 Wall (w19.M.16) Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT of = = = = = = = = = = = = = = = = = = Btu/hr 134.0 0.0740 44 436 24.0 0.5800 44 612 48.0 0.5800 44 1,225 24.0 0.5800 44 612 265.0 0.0740 44 863 181.0 0.0740 44 589 25.0 0.5800 44 638 24.0 0.5800 44 612 perimeter 68.0 0,7300 44= 2,184 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 773 Infiltration: r 1.001X 1.064 X 484 X 10.00 X 0.500 / 60] X 44 = 1 889 schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,662 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page: 65 of 102 ROOM HEATING PEAK LOADS Project Title Date balle Estado, LLC 16/13/2007 Room Information Desi n Conditions Room Name suite 105 Time of Peak Jan 12 am Floor Area 433 Outdoor Dry Bulb Temperature 6P. Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 66 of 102 R-19 Wall .19.2x6.16 69.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Height 0.0740 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = 225 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 Double Non Metal Tinted 24.0 0.5800 44 612 117.0 0.0740 44 381 Double Non Metal Tinted 24.0 0.5800 44 612 Double24.0 0.5800 44 612 Slab -On -Grade perimeter = 33.0 0.7300 44 1,060 Items shown with an asterisk (') denote conduction through an interior Infiltration: r 1.00 X 1.064 X schedule Air Sensible Fraction surface to another room. 433 X 10.00 Area Ceiling 0.500 / 6] ACH Page Total: ® pT 5340 1 690 TOTAL HOURLY HEAT LOSS FOR ROOM 7,030 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 66 of 102 ROOM HEATING PEAK LOADS Project Title Date dalle Estado LLC 16/13/2007 Room Information Desi n Conditions Room Name Suite 106 Time of Peak Jan 12 am Floor Area 578 Outdoor Dry Bulb Temperature 265E Indoor Dry Bulb Temperature 70 OF Conduction Area x X X x x x X x x x x x x x x X X x X x x x x x x x x X x x X X x x X x X x X x U -Value X X X X x X x x X X X x X x X X X x X X x x x X X X x x X X X x x X X X x x X x AT of = = = = = = = = = = = = = = = = = = = = Btu/hr R-19 Wall .19.2x6.16 114.0 0.0740 44 371 Double Non Metal Tinted 24.0 0.5800 44 612 Doubip Non Metal Tinted 48.0 0.5800 44 1,225 Double Non Metal Tinted 24.0 0.5800 44 612 30.0 0.0740 44 98 -19 Wal .19.2 6.16 290.0 0.0740 44 944 Slab -0 i-Giade-- perimeter = 53.0 0.7300 44 1,702 Items shown with an asterisk ('rr) denote conduction through an interior Infiltration: �I 1.001X 1.064 x chedule Air Sensible Fraction surface to another room. 578 x 10.00 Area Ceiling Height 0.500 / 6] ACH Page Total: 44 p7 5 565 2 255 TOTAL HOURLY HEAT LOSS FOR ROOM 7,821 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 67 of 102 ROOM HEATING PEAK LOADS Project Title Date galla Fc+arin I I ( R/1 v7nu Room Information Desicin Conditions Room Name Suite 107 Time of Peak Jan 12 am Floor Area 405 Outdoor Dry Bulb Temperature 26cF Indoor Dry Bulb Temperature 70°F Double Non Metal Tinted Conduction Area U -Value R-19 Wall .19.2x6.16 94.0 X x X X x x x x x x x X x X x x x x x x x x x x x x x x x x x x x x X x x x x 0.0740 x x x x x x X x x x x x x x x X x x x x x x x x x. x x x x x x X X x X x x x x Double Non Metal Tinted 24.0 0.5800 Double Non Metal Tented 48.0 0.5800 Double Non Metal Tinted 24.0 0.5800 210.0 0.0740 R- 9 Wall 19.2x6.16 190.0 0.0740 Slab -On -Grade perimeter = 59.0 0.7300 AT of Btu/hr 306 612 1,225 612 684 619 1,895 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 5 953 Infiltration: 1.00 x 1.064 x 405 x 10.00 x 0.500 / 6] x W = 1 580 chedule Air Sensible Area Ceiling Height ACH p7 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,534 EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 68 of 102 ROOM HEATING PEAK LOADS ,-.JProject Title Date )aIle Estado. LLC 6/13/2007 Conduction Room Information Desicin Conditions Area Room Name Suite 201 Time of Peak Jan 12 am X X X x X X X x X X X X X X X X X X x X x x X X X X X X X X x X X x X X X X X x Floor Area 619 Outdoor Dry Bulb Temperature 26 °-F Btu/hr Indoor Dry Bulb Temperature 70 OF R-30 Roof R.30.2x12.16 Conduction surface Area Area X X X X X X X X X X X X X x x X X x X x x X X x x X x x X x x X X x X x X x X X U -Value X X X x X X X x X X X X X X X X X X x X x x X X X X X X X X x X X x X X X X X x AT of = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-30 Roof R.30.2x12.16 619.0 0.0360 44 980 R-19 Wall .19.2x6.16 139.0 0.0740 44 453 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 Dnuhle Non Metal TontPrl 24.0 0.5800 44 612 R-19 Wall (W.19,26-16) 64.0 0.0740 44 208 Double Non Metal Tinted 36.0 0.5800 44 919 R-19 Wall .19.2x6.16 124.0 0.0740 44 404 919 nniffilp Non Mpt;il Tinted 36.0 05800 44= R-19 W II .19.26.16 286.0 0.0740 44= 93 DnijhIP Non Metal Tinted 24.0 0.5800 44=6119 - r Items shown with an asterisk (') denote conduction through an interior Infiltration: r 1.001 X 1.064 X `schedule Air Sensible Fraction to another room. 619 X 10.00 Ceiling Height 0.500 / 60] ACH Page Total: 44 pT 7 876 2415 TOTAL HOURLY HEAT LOSS FOR ROOM 10 292 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 69 of 102 k ROOM HEATING PEAK LOADS Project Title Date ��.allc Fcfnrfn I I r R/1 /7(1(17 Room Information Desicin Conditions Room Name Suite 202 Time of Peak Jan 12 am Floor Area 728 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF 24.0 Conduction Area U -Value 728.0 X x x x x x X x X x x x X X x x x X X x x x x X X X x x x X x x x x x x x x x 0.0360 x x X X X x x x X x x X X x x x X x x x x x x x x x x x x x x x x x x x x x X 64.0 0.0740 24.0 0.5800 48.0 0.5800 24.0 0.5800 200.0 0.0740 151.0 0.0740 30.0 0.5800 0-5800 280.0 0.0370 AT of Btu/hr 1.1531 208 612 1,225 612 651 492 766 612 456 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 6 788 Infiltration: r 1.00 x 1.064 x 728 X 10.00 x 0.500 / 60] X 44 = 2 841 `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 79,62791 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 70 of 102 ROOM HEATING PEAK LOADS Project Title Date Salle Estado, LLC 16/13/2007 Room Information Desi n Conditions Room Name Suite 203 Time of Peak Jan 12 am Floor Area 781 Outdoor Dry Bulb Temperature 266E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr R-30 Roof R.30.2x12.16 . Area 781.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0360 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = 1,237 R-19 Wall W.19.2x6.16 134.0 0.0740 44 436 DnuhIP Nnn Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 612 r)m ship Nnn Metal Tinted 24.0 0.5800 44 R-19 Wall (W.19.2x6.16) 176.0 0.0740 44 573 Double Nda Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 30.0 0.5800 44 766 - 366, 0 44 J 92 Solid Wood Door 24.0 1.4500 44 1,531 33 R-1 A FInnr Assembly 266.0 0.0370 44=4 i Items shown with an asterisk (•) denote conduction through an interior Infiltration: 1.00 X 1.064 X chedule Air Sensible Fraction surface to another room. 781 X 10.00 Ceiling Height 0.500 / 60] ACH Page Total: U QT 9 230 3048 TOTAL HOURLY HEAT LOSS FOR ROOM 12,278 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page:71 of 102 ROOM HEATING PEAK LOADS Project Title Date 11MII1M pctarin I I C R/1,A/9nn7 Room Information Desian Conditions Room Name Suite 204 Time of Peak Jan 12 am Floor Area 860 Outdoor Dry Bulb Temperature 266F Indoor Dry Bulb Temperature 70 OF 24.0 Conduction Area U -Value 860.0 X x X x x X X X X x X x X x X X X X X X X x x X x x X x x x X x X x X X x x X 0.0360 X X X x x X X X X X X x x x x X x x X x x x x x x x x x X x x x x x x x X x x 134.0 0.0740 24.0 0.5800 48.0 0.5800 24.0 0.5800 366.0 0.0740 24.0 1.4500 246.0 0.0740 05800 24.0 0.5800 266.0 0.0370 AT of Btu/hr Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 9 583 Infiltration: 1.001 x 1.064 x 860 x 10.00 x 0.500 I6] x 44 = 3356 chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,939 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:72 of 102 ROOM HEATING PEAK LOADS Project Title Date �kallP Fstarin I LC 16/13/2007 Room Information Desicin Conditions Room Name Suite 205 Time of Peak Jan 12 am Floor Area 1,733 Outdoor Dry Bulb Temperature 26°-F Indoor Dry Bulb Temperature 70 OF 188.0 Conduction Area X X X X X X X X x X x X X X X X X X X X X X X X X X X x X X x X X X X X X X X U -Value X X X X X X X X X x X x X X x X X X X x X X X X X X X X X X X X X x X X X X X 1733.0 0.0360 188.0 0.0740 24.0 0.5800 48.0 0.5800 24.0 0.5800 24.0 0.5800 48.0 0.5800 24.0 0.5800 95.0 0,0740 30.0 0.5800 307.0 0.0740 48.0 0.5800 25.0 0,5800 510.0 0,0740 63 0.0370 AT of Btu/hr 2.7451 612 612 1,225 612 612 1.225 612 309 766 1,225 638 1.661 Items shown with an asterisk (f•) denote conduction through an interior surface to another room. Page Total: 14,283 Infiltration: 1.00 x 1.064 x 1 733 x 10.00 x 0.500 / 6] x 44 = 6 762 chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,046 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 73 of 102 ROOM HEATING PEAK LOADS Project Title Date $a11e Estado, LLC 16/13/2007 Room Information Design Conditions Room Name Suite 206 Time of Peak ,tan 12 am Floor Area 690 Outdoor Dry Bulb Temperature 26oF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 690.0 320.0 175.0 17.5 17.5 232.5 17.5 17.5 175 17.5 17.5 130.0 16.0 8.0 6 690.0 x x x x x x X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44 = = = = = = = = = = = = = = = = = = = = = = = = 1,093 44 1,042 44 570 44 447 44 447 44 757 44 447 44 447 44 447 44 447 44 423 44= 408 44= 1,225 44 OR 44 1,123 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 176 Infiltration: 1 1.00 x 1.os4 x s90 x 10.00 x o.500 / 60] x 0 = 2 s92 chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,$66 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 74of 102 I ROOM COOLING PEAK LOADS Title I Date .� Calle Estado, LLC 1 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 1o1 Time of Peak Jul 3 pm Floor Area 820 Outdoor Dry Bulb Temperature 112 "� Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 -19 Wall W.19.2x6.16 -19 Wall .19.2x6.16 0.590 0.811 (N) 48.0 Area 178.0 X 140.0 X 108.0 X 64.0 X 164.0 X 346.0 X 15.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (`) denote conduction through an interior surface to another room. Solar Gain U -Value 0.0740 0.5800 DETD 1 37.8 = 27.9 = 27.9 = 39.2 = 40.1 40.2 = 58.2 = Page Total Orientation Area X X X x x X x X X X SGF x X X x X X X x X X SC Weighting X X X x X x X X X X Factor = = = = = = = = (N) 24.0 41 0.590 0.811 (N) 48.0 4 0.590 0.811 (N) 24.0 41 0.590 0.81 (N) 36.0 41 0.590 0.807 (NE) 36.0 41 0.590 1.217 (E) 36.0 41 0.590 1.532 (S) 20.0 42 0.590 0.793 (S) 24.0 42 0.590 0.793 Page Total Btu/hr 498 2,266 1,748 185 487 1,030 65 s 277 Btu/hr 471 942 471 703 1,060 1,334 393 471 5 845 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 820 x 0.794 Watts/sqft X 3.41 Btuh/Watt x 0.999 = 2,219 ccu ants 1.0c x 820 X 300 Btuh/occ. / 10 Sgft/occ. x 1.00 = 2.46 Receptacle 1.0c x 820 X 1.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 2,799 rocess 1.0 x 820 x 0.00o Watts/sqft x 3.411, Btuh/Watt x 1.00 = 0 Infiltration:1.00 x 1.064 x 820 x 10.00 x 0.50 /601 x 38 = 2 763 Ledule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,363 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 x 820 x 3001 Btuh/occ. / 100 sgft/occ. = 2 460 Receptacle _100. x xWatts/sgft x Btuh/Watt= rocess 1.00 x Seo x o.000 Watts/sgft x 1 3.413 Btuh/Watt = o Infiltration: x a77 x Area x x ACH /6] x®= 128 chedule Air Latent Ceiling Height CH DW ROOM COOLING PEAK LOADS' ,JProject Title aIle Estado, LLC -- ]Room Name Floor Area Indoor Dry Bulb Temperature Conduction h-19 Wall (W.19.2x6.16) ouble Non Metal Tinted Suite 102 1 Time of Peak 433 1 Outdoor Dry Bulb Temperature 74c� Outdoor Wet Bulb Temperature Area 69.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.07401 Date . 6/13/2007 DETD 1 X X X X X X X X X 37.8 = = = = = = = = = 27.9 40.2 27.9 ' Weighting x X x X X X x X X X Factor = = = = = = = = = U 24.0 Page Total Orientation Area X X X X X X X X x X SGF X X X X X X x X X x SC ' Weighting x X x X X X x X X X Factor = = = = = = = = = U 24.0 41 0.590 0.811 (NN) 48.0 41 0.590 0.811 (N) 24.0 41 0.590 0.811 (S) 24.0 42 0.590 0.793 (S) 25.0 42 0.590 0.793 Page Total Jul 3 pm 112 Fr 78 OF Btu/hr 193 1,942 345 405 2 885 Btu/hr 471 942- 471 472 491 2 847 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c X 433 X 1.289 Watts/sgft X 3.41 Btuh/Watt X 0.999 = 1,902 Occupants 1.0 X 433 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 1,29 Receptacle 1.0 X 433 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 2,217 rocess 11.0c x 433 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: I 1.00 x 1.064 x 433 x 10.00 x 0.50 / 60] x 1 38 = 1 459 Fraction a Air Sensible Area Ceiling Height ACH a T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,608 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 100 X 433 x 3001 Btuh/OCC. / 1 1001 sgft/OCC. = 1 299 Receptacle 1.00 x x 0 0001 Watts/sgft x 1 3 4131 Btuh/Watt = rocess 1.00 X 433 X 0.000 Watts/sgft x 1 3.413 Btuhfwatt = 0 Infiltration: xCg 7 x x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH DW ROOM COOLING PEAK LOADS Project Title Date `� Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 103 Time of Peak Jul 4 pm Floor Area 484 Outdoor Dry Bulb Temperature 111 Indoor Dry Bulb Temperature 74`k Outdoor Wet Bulb Temperature 78 91= Conduction -19 Wall .19.24.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Solid Wood Door Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window " indow U -Value 1 0.07401 X X X X X X X X X DETD = = = = = = = = = 38.4 28.3 39.0 28.3 61.5 58.3 (N) 24.0 35 Page Total Orientation Area X X x X X x X X X x SGF X X X X x x x X X X SC WeightingFactor X X X X X X x X X X = = = = = = (N) 24.0 35 0.590 1.011 (NN) 48.0 35 0.590 1.011 (N) 24.0 35 0.590 1.011 (S) 24.0 33 0.590 1.071 (S) 25.0 33 0.590 1.071 Page Total Btu/hr 381 1,966 522 410 1,097 2,028 6 404 Btu/hr 501 1,002 501 500 521 3 025 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 484 X 1.285 Wafts/sgft X 3.41 Btuh/Watt X 1.000 = 2,123 ccu ants 1.0c X 484 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 1,452 Receptacle 1.0 X 484 X 0.500 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 826 rocess 1.0 X 484 X 1.500 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 2,478 Infiltration:1.00 x 1.064 x 484 X 10.00 x 0.50 /601 x 38 = 1,631 Cedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17 938 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 x 484 X 3001 Btuh/OCC. / L 1001 sqft/occ. = 1 452 Receptacle 1 0n x x Watts/sgft x 1 3 4131 Btuh/Watt = rocess 1.00 X 484 X 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = o Infiltration: xx 4s4 x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING PEAK LOADS _.Project Title Date \J Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 104 Time of Peak Jul 3 pm Floor Area 484 Outdoor Dry Bulb Temperature 112 9P Indoor Dry Bulb Temperature 78`� Outdoor Wet Bulb Temperature 78 OF Conduction 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall W.19.24.16 Double Non Metal Tinted Area 134.0 120.0 265.0 181.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value X X X X X X X X X DETD 1 = = = = = = = = = 34.4 24.5 36.8 37.1 24.5 (N) 24.0 41 0.876 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X Weighting SC 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X X X X X X Factor = = = = = = = (N) 24.0 41 0.876 (N) 48.0 41 0.876 (N) 24.0 41 0.876 (S) 25.0 42 0.868 (S) 24.0 42 0.868 Page Total Btu/hr 341 1,704 722 497 355 3 619 Btu/hr 509 1,018 509 538 516 3 089 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 X 484 X 1.285 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,123 ccu ants 1.0 X 484 X 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,452 Receptacle 1.0 x 484 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 826 rocess Lhedule 1.o x 484 x o.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 484 x 10.00 x 0.50 /6]x Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,567 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 484 x 300 Btuh/OCC. / 100 sgft/occ. = 1452 Receptacle 1.nn x x 0 000 Wafts/sgft x Btuh/Watt = rocess 1.00 X 484 X 0.000 Watts/sqft x1 Btuh/Watt = 0 Infiltration:L xx x =10 x 60] x _ chedule Air Latent Area Ceiling Height ACH AN ROOM COOLING PEAK LOADS Project Title Date r Calle Estado,ILC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 105 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 78 `k Conduction `2-19 Wall (W.19.2x6.16) Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.07401 X X X X X X X X X DETD t = = = = = = = = = 34.4 24.5 37.1 Weighting X X X X X x X X X X Factor = = = = = = = = = = (N) 24.0 41 Page Total Orientation Area X x X x X x X X X. X SGF X X X x X x X X x X SC Weighting X X X X X x X X X X Factor = = = = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Btu/hr 176 2,045 321 2 541 Btu/hr 509 1,018 509 516 516 3 067 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 433 x 1.289 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 1,904 ccu ants 1.0c x 433 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,299 Receptacle 1.0 x 433 X 0.500 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 739 rocess 1.0c x 433 x 0.000 Watts/sgft x 3.41 Btuh[Watt x 1.�00 = 0 Infiltration: 1.00 x 1.064 x 433 x 10.00 x 0.50 /601 x I 341 = 1 306 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,857 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 433 x 3001 Btuh/OCC. / 100 sgft/OCc. = 1 299 Receptacle 1.00 x x Watts/sgft x BtuhNVatt = Process 1.00 x 433 X 0.000 Wafts/sgft x 3.413 Btuh/Watt = o Infiltration: xC x 433 x 10.00 x � / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pgy ROOM COOLING PEAK LOADS 77771 project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 106 Time of Peak Jun 5 pm Floor Area 578 Outdoor Dry Bulb Temperature 106 � Indoor Dry Bulb Temperature 789F Outdoor Wet Bulb Temperature 74 OF Conduction k -19 Wall (W.19.2x6.16) I Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window U -Value X X X X X X X X X DETD ' = = = = = = = = = 33.6 21.3 30.4 52.0 Factor = = = = = (N) 24.0 57 Page Total Orientation Area X X X x x x x X X X SGF X X X x x X X X X X SC Weighting X X x X X x x x X X Factor = = = = = (N) 24.0 57 0.590 0.733 (N) 48.0 57 0.590 0.733 (N) 24.0 57 0.590 0.733 Page Total Btu/hr 283 1,188 68 1,115 2 655 Btu/hr 591 1,183 591 2 366 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 578 x 1.287 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 2,539 ccu ants 1.0 X 578 X 300 Btuh/OCC. / 10 sgft/occ. x 1.00 = 1,734 Receptacle 1.0 X 578 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 986 rocess 1.0 X 578 X 0.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 578 x 10.00 x 0.50 /601 x I 341 = 1 743 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,022 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 578 x 3001 Btuh/occ. / 100 sqft/occ. = 1 734 Receptacle 1.00 x x 0.0001 Watts/sgft x Btuh/Watt = Process 1.00 X 578 x 0.000 Wafts/sgft x 1 3.413 Btuh/Watt = 0 Infiltration: x x x x �� / 6] x � = 209 chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING PEAK LOADS 71 roject Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 107 Time of Peak Jul 3 pm Floor Area 405 Outdoor Dry Bulb Temperature 112 $ Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 78 C' Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Area X X X X X X X X X U -Value X X X X X X X X X 94.0 0.0740 24.0 0.5800 48.0 0.5800 24.0 0.5800 210.0 0.0740 190.0 0.0740 0.590 Window (E) 24.0 41 0.590 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area x X X x X X X X X X SGF X X X X X X X X X X SC Window (E) 24.0 41 0.590 Window U 48.0 41 0.590 Window (E) 24.0 41 0.590 _y DETD ' 36.8 = 24.5 = 24.5 = 24.5 = 37.1 = 55.11 = Page Total Btu/hr 256 341 682 341 576 775 2 971 Weighting X X X X X X X X x X Factor = = = = = = = Btu/hr 1.116 648 1.116 1,296 1.116 648 Page Total 1 2.593 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c X 405 X 1.378 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 1,904 ccu ants 1.0 X 405 X 300 Btuh/occ. / 10C sqft/occ. x 1.00 = 1,215 Receptacle 1.0 X 405 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 691 rocess 1.0c X 405 X 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration: �cne1.0e x AirSensiblex Area Coiling X Ceiling HeightX ACH 50 /601 X 34 = 1 221 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,595 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 405 X 3001 Btuh/occ. / 100 sgft/occ. = 1 215 Receptacle 1.00 x x Watts/sgft x 1 3.41 a I BtuhlWatt = Process 1.00 X 405 X 0.0001 Watts/sgft X F 3.413 Btuh/Watt = o Infiltration: xx x 1n 00 x � / 6] x � = 23 chedule AIr Latent Area Ceiling Height ACH pW ROOM COOLING PEAK LOADS Title Date Calle Estado. LLC I 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 201 Time of Peak Jul 2 pm Floor Area 619 Outdoor Dry Bulb Temperature 111 �- Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 78 `k Conduction -30 Roof(R.30.202.16) -19 Wall W.19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Area 619.0 139.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value Orientation Area X X X X X x X X X X SGF X X X X X X X X X X Sc (N) 24.0 46 0.590 (N) 48.0 46 0.590 (N) 24.0 46 0.590 (NE) 36.0 46 0.590 (E) 36.0 46 0.590 (S) 24.0 49 0.590 DETD 1 74.2 = 32.9 = 23.2 = 34.5 = 23.2 = 35.7 = 23.2 = 38.9 = Page Total Weighting Factor X 0.773 = X 0.773 = x 0.773 = X 1.182 = X 1.510 = X 0.739 = X X = X X Page Total Btu/hr 1,654 338 1,612 163 483 327 483 823 5 886 Btu/hr 504 1,008 504 1,155 1,476 512 5 158 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c X 619 x 1.052 Watts/sqft x 3.41 Btuh/Watt X 1.000 = 2,222 ccu ants 1.0 X 619 x 300 Btuhlocc. / lot sgft/occ. x 1.00 = 1,857 Receptacle 1.0 X 619 x 0.500 Watts/sqft X 3.41 BtuhlWatt X 1.00 = 1,056 rocess 1.0 x 619 x o.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 x 619 X 10.00 X 0.50 /601 X 34 = 1,866 cheduie Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,046 Sched. Latent Gain Frac. Area Heat Gain Btu/hr occupants 1.00 x 619 x 300Btuhlocc. / loo sgft/occ. = 1 857 Rece tale 1.00 x x Watts/sgft x Btuh/Watt = rocess 1.00 x s1s x 0.00o Watts/sgft x 3.413 Btuh/Watt = o Infiltration: 1.06 x x x x �� / 6] x cheduie Air Latent Area Ceiling Height ACH pN► ROOM COOLING PEAK LOADS Pro ject Title Date ) Calle Estado, LLC 6/13/2007 r ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 202 Time of Peak Jul 3 pm Floor Area 728 Outdoor Dry Bulb Temperature 112 �- Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 78 OF Conduction 30 Roof R.30.2A2.16 -19 Wall .19.24.16 Double Non Metal Tinted -19 Wall .19.24.16 -19 Wall .19.24.16 Double Non Metal Tinted 19 Floor Assembly Area 1 728.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window tdow Orientation Area _(N) 24.0 (N) 48.0 (N) 24.0 (S) 30.0 (S) 24.0 U -Value 1 0.03601 1 0.03701 SGF ��« X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X X X X F - x DETD 1 70.3 = 34.4 = 24.5 = 36.8 = 37.1 = 24.5 = 28.6 = Page Total Weighting Factor X 0.876 = X 0.876 = X 0.876 = X 0.868 = X 0.868 = X X = X = X = X = Page Total Btu/hr 1,842 163 1,704 545 414 426 297 5 391 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 728 X 1.022 Wafts/sqft X 3.41 Btuh/Watt ' x 1.000 = 2,539 ccu ants 1.0c X 728 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 2,184 Receptacle 1.0 X 728 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,242 rocess r1.o x 728 x 0.000 Watts/sgft X 3.41 BtuhlWaft x 1.00 = 0 Infiltration: I 1.00 x 1.osa x 72a x 10.0o x o.50 / 6] x = 2 195 'Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,748 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Dccu ants 1.00 x 728 x 300 Btuh/occ. / 100 sgft/occ. = 2184 Receptacle 1.no x x Wafts/sgft x L 3Ai3l Btuh/Watt = rocess 1.00 x 728 x 0.000 Wafts/sqft x 3.413 Btuh/Watt = o Infiltration: � x x � x 10 Do x AC / 6] x chedule Alr Latent Area Gelling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 g Energ Pro By Energ Soft User Number: User Page:83 of 102 ROOM COOLING PEAK LOADS ject Title Date Calle Estado, LLC 1 6/13/2007 )OM INFORMATION nFStr;N FF)KEITtnNC om Name r Area or Dry Bulb Temperature Conduction -30 Roof R.30.2x12.16 19 Wall .19.24.16 Double Non Metal Tinted 19 Wall W.19.24.16 -19 Wall .19.24.16 Solid Wood Door -19 Floor Assembly Suite 203 781 789= Time of Peak Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Area X X X X X X X X X U -Value X X X X X X X X X DETD = = = = = = = = = 781.0 0.0360 70.3 134.0 0.0740 34.4 150.0 0.5800 24.5 176.0 0.0740 37.1 366.0 0.0740 55.1 24.0 1.4500 52.9 266.0 0.0370 28.6 (S) 30.0 42 0.590 0.868 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (`) denote conduction through an interior surface to another room. Solar Gain Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 30.0 42 0.590 0.868 Page Total Jul 3 pm 112 C� 78 C� Btu/hr 1,976 341 2,130 483 1,493 1,842 282 8 548 Btu/hr 509 1,018 509 516 645 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 781 X 1.273 Watts/sgft x 3.41 Btuh/Watt x 1.000 = 3,392 ccu ants 1.0c X 781 X 300 Btuh/OCC. / 10 sgft/OCC. X 1.00 = 2,343 Receptacle 1.0 X 781 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,333 rocess 1.0 x 781 x 0.000 Watts/sqft X 3.411 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 X 781 X 10.00 X 0.50 /601 X L I = 2 355 chedule Air Sensible Area Calling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,167 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 781 X 3001 Btuh/OCC. / 100 sgft/occ. = 2 343 Receptacle 1.on x x Watts/sgft x Btuh/Watt = Process 1.00 X 781 x 0.000 Watts/sgft X 1 3.4131 BtuhrWatt = 0 Infiltration: xx 7811 x x / 60] x _ chedule Air Latent Area Ceiling Height ACH zSW ROOM COOLING PEAK LOADS project Title Date Calle Estado, LLC 6/13/2007 tcOOM INFORMATION DESIGN CONDITIONS Room Name Suite 204 Time of Peak Jul 3 pm Floor Area 860 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 78 C� Conduction -30 Roof R.30.2x12.16 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 olid Wood Door -19 all .19.2x6.16 -19 Floor Assembly Area 860.0 X 134.0 X 150.0 X 366.0 X 24.0 X 246.0 X 266.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 DETD 1 X X X X X X X X X 70.3 = = = = = = = 34.4 24.5 36.8 30.8 37.1 = = = = = = = (N) 24.0 Page Total Orientation Area X x X X X x X X X X SGF X X x X X X x X x x SC Weighting x X X X X X x X X X Factor = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 30.0 42 0.590 0.868 S 24.0 42 0.590 0.868 Page Total Btu/hr 2,176 341 2.130 997 1.071 675 282 7 672 Btu/hr 509 1,018 509 645 516 3=196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 860 X 1.264 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 3,709 ccu ants 1.0c X 860 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 2,580 Receptacle 1.0 x 860 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,468 rocess r.0 x 860 x 0.000 Watts/sgft X 3.41 Btuh[Watt x 1.00 = 0 Infiltration: I 1.00 x 1.064 x 860 x 10.00 x 0.50 / 60] x 34 = 2,593 -Schedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,219 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccupants 1.00 X 860 X 300 Btuh/OCC. / 1 1001 sgft/OCc. = 2580 Receptacle 1.00 x x n nan Watts/sgft x 1 14131 Btuh[Watt = rocess 1.00 x 860 X 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = o Infiltration: x x E x x n sc / 6] xL-So oozsz = Rq� chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 205 Time of Peak Jul 3 pm Floor Area 1,733 Outdoor Dry Bulb Temperature 112 9 Indoor Dry Bulb Temperature 789: Outdoor Wet Bulb Temperature 78 `F Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 ouble Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Floor Assembly Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window �d w .:•indow Window Window Window Orientation Area (N) 24.0 (N) 48.0 (N) 24.0 (N) 24.0 (N) 48.0 N 24.0 (E) 30.0 (S) 48.0 (S) 25.0 U -Value 1 0.03601 SGF x 4 X 4 x 41- x 4 X 4 x 4 X 4 x 42 x 42 X SC X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 x 0.590 x 0.590 X DETD 1 70.3 = 34.4 = 24.5 = 36.8 = 24.5 = 37.1 = 24.5 = 55.1 = 28.6 = Page Total Weighting Factor X 0.876 = X 0.876 = X 0.876 = x 0.876 = X 0.876 = X 0.876 = X 1.270 = x 0.868 = x 0.868 x Page Total Btu/hr 4,385 479 3,408 259 426 843 355 2.080 279 12 513 Btu/hr 509 1,018 509 509 1,018 509 922 1 032 538 6 562 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 1,733 x 0.939 Watts/sgft x 3.41d Btuh/Watt X 1.000 = 5,556 ccu ants 1.0 X 1,733 X 300 Btuh/OCC. / 10 sgftlocc. X 1.00 = 5,199 Receptacle 1.0 X 1,733 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 2,957 rocess 1.0 X 1,733 X • 0.000 Watts/sqft x 3.411 Btuh/Watt X 100 = 0 Infiltration: 1.00 X 1.064 X 1 733 X 10.00 x 0.50 /601 X I 341 = 1 5 225 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 38,013 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 1 733 X 3001 Btuh/occ. / F 100 sqft/occ. = 5199 Receptacle 1.00 x x 0,0001 Watts/sgft x Btuh/Watt = Process 1.00 X 1,733 X 0.000 Wafts/sgft X 1 3.413 Btuh[Watt = 0 Infiltration: Le lx x x x �/6] xeduAir Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7,008 Energ Pro By Energ Soft User Number. User Pa e:86 of 102 ROOM COOLING PEAK LOADS Title Date 1 Calle Estado, LLC 1 6/13/2007 1 Room Name suite 206 Time of Peak Sep 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 107 �k Indoor Dry Bulb Temperature 789F Outdoor Wet Bulb Temperature 74 O Conduction -30 Roof R.30.2x12.16 -19 Wall .19.24.16 -19 Wall .19.2x6.16 ouble Non Metal Tinted ouble Non Metal Tinted -19 Wall .19.2x6.16 ouble Non Metal Tinted ouble Non Metal Tinted Double Non Metal Tinted Area 690.0 X 320.0 X 175.0 X 17.5 -X 17.5 X 232.5 X 17.5 X 17.5 X 17.5 X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 0.0740 0.5800 0.5800 0.0740 0.5800 0.5800 0.5800 DETD 1 X X X X X X X X X 51.6 = = = = = = = = = 27.5 29.8 20.4 20.4 41.6 20.4 20.4 20.4 Page Total Orientation Area X x X X X X X X X x SGF X X x X X x X X X x Sc Weighting X x X x x x X X X X Factor = = = = = = = = = = (E) 17.5 27 0.590 2.331 (E) 17.5 27 0.590 2.331 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (S) 17,5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (W) 16.0 76 0.590 0.495 48.0 76 0.590 0.495 16.0 1 76 1 0.590 0.495 Page Total Btu/hr 1,283 652 385 207 207 716 207 207 207 4 072 Btulhr 650 650 1.220 1,220 1.220 1,220 1,220 354 1 062 354 9 171 Sched. Weighting Internal Gain Frac.. Area Heat Gain Factor Btu/hr fights 1.0c X 690 x 1.078 Watts/sqft x 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c x 690 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 2.07 Receptacle 1.0 x 690 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 1,177 rocess 1.0 x 690 X 0.000 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 x 690 x 10.00 x 0.50 /601 x I 341 = 2 081 -Schedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM23,555 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 690 x 3001 Btuh/occ. / loo sgftlocc. = 2 070 Receptacle 1.nn x xnon Watts[sgft x 1 3 4131 Btuh/Watt = Process- 1.00 x 690 x 0.000 Watts/sgft X 1 3.413 Btuh/Watt = o Infiltration: xx x x / 6] xL-S chedule A1r Latent Area Ceiling Height ACH pyy 11100M COOLING PEAK LOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Sep 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 107 `- Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 74 OF Conduction Double Non Metal Tinted Double Non Metal Tinted 19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tint d -19 Floor Assembly Area X X X X X X X X X U -Value 17.5 0.5800 17.5 0.5800 130.0 0.0740 16.0 0.5800 48.0 0.5800 16.0 0.5800 690.0 0.0370 1. Design Equivalent Temperature Difference (D=TD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain X X X X X X X X X DETD t = = = = = = = = = 20.4 20.4 50.0 20.4 20.4 20.4 23.6 Page Total Weighting Orientation Area SGF SC Factor x x x = x x x = x x x = X x x = X x x = x x x = X x x = X x x = X x x = x x x = Page Total Btu/hr 207 207 481 189 568 189 603 2 446 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 690 x 1.078 Watts/sqft x 3.41 Btuh/Waft X 1.000 = 2,539 ccu ants 1.0c x 690 x 300 Btuh/occ. / 10 sgft/OCc. x 1.00 = 2,070 Receptacle 1.0c x 690 x 0.500 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 1,177 rocess 1.0c x 690 x 0.000 Watts/sgft x 3.41 Btuh[Watt x 1.00 = 0 Infiltration:1.00 x 1.064 x 690 x 10.00 x 0.50 /601 x = 2 081 Ledule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,555 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 x 690 x 3001 Btuh/occ. / F 100 sqft/occ. = 2 070 Receptacle -1-nn x x Watts/sgft xBtuh/Waft = rocess 1.00 x 690 x 0.000 Watts/sqft x 3.413 BtuhlWatt = o Infiltration: x x x E� x / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS Project Title ( Date Calle Estado, LLC 6/13/2007 ,OM INFO om Name Floor Area Indoor Dry Bulb Temperature Conduction -19 Wall .19.24.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall 19.2x6.16 -19 Wall .19.24.16 -19 Wall .19.2x6.16 19 Wall W.19.2x6.16 (NE) 36.0 (E) Suite 101 1 Time of Peak 820 1 Outdoor Dry Bulb Temperature 74c� Outdoor Wet Bulb Temperature Area 178.0 X 140.0 X 108.0 X 64.0 X 164.0 X 346.0 X 15.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area (N) 24.0 (N) 48.0 (N) 24.0 (N) 36.0 (NE) 36.0 (E) 36.0 (S) 20.0 (S) 24.0 U -Value 0.0740 0.5800 SGF X 4 X 41 X 4 x 4 x 4 X 4 x 42 x 42 x x SC x 0.590 x 0.590 X 0.590 x 0.590 x 0.590 X 0.590 x 0.590 x 0.590 X X DETD 1 37.8 = 27.9 = 27.9 = 39.2 = 40.1 = 40.2 = 58.2 = Page Total Weighting Factor x 0.811 = x 0.811 = X 0.811 = x 0.807 = x 1.217 = x 1.532 = x 0.793 = x 0.793 = x x Page Total Jul 3 pm 112 0 78 OF Btulhr 498 2,266 1,748 185 487 1. 030 65 sen Btulhr 471 942 471 703 1,060 1,334 393 471 5,845 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0c x 820 X 0.794 Watts/sgft x 3.41 Btuh/Watt X 0.999 = 2,219 ccu ants 1.0c X 820 X 300 Btuh/OCC. / 10 sgft/occ. x 1.00 = 2,460 Receptacle 1.0 x 820 x 1.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 2,799 rocess r1.o x 820 x o.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: I 1.00 x 1.osa x 820 x 10.00 x 0.50 /601 x 38 = 2 763 'Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,363 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 820 x 3001 Btuh/OCC. / 100 sgft/occ. = 2 460 ece tacle 1.00 x x a 0001 Watts/sgft x 1 3 ial Btuh/Watt - rocess 1.00 x 820 X 0.000 Watts/sgft X 1 3.413 Btuh[ Watt = 0 Infiltration: nJ x x x x � / 6] x � _ �1 chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Project Title 1 Calle Estado, LLC oat® 6/13/2007 Room Name Suite 102 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 `k= Indoor Dry Bulb Temperature 74�: Outdoor Wet Bulb Temperature 78 9= Conduction 19 Wall (W.1 Area 1. Design Equivaient Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0740 0.5800 DETD t 37.8 = 27.9 = 40.2 = 27.9 = Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X Sc Weighting x X X X X X X X X, X Factor = = = = = _ (N) 24.0 4 0.590 0.811 (N) 48.0 4 0.590 0.811 N 24.0 4 0.590 0.811 (S) 24.0 42 0.590 0.793 (S) 25.0 42 0.590 0.793 Page Total Btu/hr 193 1 942 345 405 2 685 Btu/hr 471 942 471 472 491 2 847 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 X 433 X 1.289 Watts/sgft X 3.41 Btuh[Watt X 0.999 = 1,902 ccu ants 1.0 X 433 X 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 1,299 Receptacle 1.0 X 433 X 1.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 2,217 rocess 1.0 x 433 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 433 x 10.00 x 0.50 / 6] x 38 = 1 459 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,608 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 433 X 3001 Btuh/OCC. / 100 sgft/occ. = 1 299 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = rocess 1.00 X 433 x 0.000 Watts/sgft xi 3.413 Btuh/Watt = 0 Infiltration: 1 n0 x x 433 x x�/ 6] x 0 0039g� _ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS Project Title I Date - j Calle Estado, LLC 6/13/2007 .:OOM INFORMATION DESIGN CONDITIONS Room Name suite 103 Time of Peak Jul 3 pm Floor Area 484 Outdoor Dry Bulb Temperature 112 1; Indoor Dry Bulb Temperature 74(� Outdoor Wet Bulb Temperature 78 CI= Conduction -19 Wall W.19.2x6.16 Double Non Metal Tinted 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Solid Wood Door Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.07401 DETD ' X X X X X X X X X 38.4 = = = = = = = = 28.3 41.1 28.3 59.1 55.2 = = = = = = = (N) 24.0 Page Total Orientation Area X X X X X X X X X X SGF X X X x X X X X X X Sc Weighting X X X x X X X X X x Factor = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 25.0 42 0.590 0.868 Page Total Btu/hr 381 1,971 550 411 1.054 1 921 6 288 Btu/hr 509 1,018 509 516 538 3 089 Sched. Weighting gtu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 484 X 1.285 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,123 ccu ants 1.0c x 484 X 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 1452 Receptacle 1.0 X 484 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 826 rocess 1.0 X 484 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 2,478 Infiltration: 1.00 X 1.064 X 484 X 10.00 X 0.50 I6] X 38 = 1631 FE chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,886 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 484 X 3001 Btuh/OCC. / 100 sgft/occ. = 1 452 Receptacle 1.0o x x 0,0001 Watts/sgft x a 41 a I Btuh/Watt = rocess 1.00 X 484 x 0.000 Watts/sgft x 13.413 Btuh/Watt = 0 Infiltration: F= xx x x 1 n 5(11 / 60] x _ �z L -Schedule Air Latent Area Ceiling Height ACH pyy User Number: User ROOM COOLING COIL LOADS Conduction k-19 Wall (W.19.2x6:16) Area 134.0 120.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.07401 DETD X X X X X X X X X 34.4 = = = = = = = = = 24.5 36.8 37.1 24.5 Factor = = = = = = (N) 24.0 Page Total Orientation Area X X XE42 X X X X X x X SGF X X X X x X X X x x SC Weighting X X X x X X X x x x Factor = = = = = = (N) 24.0 0.590 0.876 (N) 48.0 0.590 0.876 (N) 24.0 0.590 0.876 (S) 25.0 0.590 0.868 (S) 24.0 0.590 0.868 Page Total Btu/hr 341 1,704 722 497 355 3 619 Btulhr 509 1,018 509 538 516 3 089 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor fights 1.0c x 484 x 1.285 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 2,123 ccu ants 1.0 x 484 X 300 Btuh/OCC. / 10 sgft/occ. x 1.00 = 1,452 Receptacle 1.0 x 484 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 826 rocess 1.0 X 484 X 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: F 1.00 x 1.064 x 484 x 10.00 x 0.50 / 6] x = 1 459 'Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,567 Sched. Btuihr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 484 x 3001 Btuh/OCC. / 100 sgftlocc. = 1452 Receptacle 1.00 x x 0 00 Watts/sgft x 1 3 4111 Btuh/Watt = Process 1.00 x 484 x 0.000 Wafts/sgft x 3.413 Btuh/VI/att = o Infiltration: xx 48 x x / 60] x Cpj;�2 _ L -Schedule Air Latent Area Ceiling Height ACH Z llw ROOM COOLING COIL LOADS J?rojec, t Title ROOM INFO Room Name Calle Estado, LLC loor Area idoor Dry Bulb Temperature Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Suite 105 1 Time of Peak 433 I Outdoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature Area 69.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow U -Value Date 6/13/2007 DETD 1 34.4 = 24.5 = 37.1 = Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Jul 3 pm 112 78 OF Btu/hr 176 2,045 321 2 541 Btu/hr 509 U18 509 516 516 3 067 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 11.0c x 433 x 1.289 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 1,904 ccu ants 1.0 x 433 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,299 Receptacle 1.0 x 433 X 0.500 Watts/sqft x 3.41 Btuh[Watt x 1.00 = 739 rocess r1.0c x 433 X 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration: I 1.00 x 1.064 x 433 x 10.00 x 0.50 /601 x = 1,306 "�-- chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,857 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 433 X 300 Btuh/OCC. / 100 sgft/occ. = 1 299 Receptacle 1.00 x x 0 non Watts/sgft x Btuh/Watt = rocess 1.00 X 433 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: x x 433 x x � / 6] x � _ chedule Alr Latent Area Ceiling Height ACH AW ROOM COOLING COIL LOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 106 Time of Peak Jul 3 pm Floor Area '578 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 78 OF Outdoor Wet Bulb Temperature 78 9F Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window U -Value X X X X X X X X X DETD 1 = = = = = = = = = 34.4 24.5 36.8 55.1 Factor = = = = = = I= (N) 24.0 41 Page Total Orientation Area X X X X X x X X X X SGF X X X x X X X X x X Sc Weighting X X X x X X X X X x Factor = = = = = = I= (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 I Page Total Btu/hr 290 1,363 82 1,183 2 918 Btu/hr 509 1,018 509 2 035 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 578 x 1.287 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 2,539 ccu ants 1.0 X 578 X 300 Btuh/OCC. / 10 sgft/occ. x 1.00 = 1,734 Receptacle 1.0 X 578 X 0.500 Wafts/sqft X 3.41 Btuh/Watt X 1.00 = 986 rocess 1.0 X 578 X 0.000 Wafts/sgft X 3.41 Btuhf Watt . x 1.00 = 0 Infiltration: 1.00 X 1.064 x 578 x 10.00 X 0.50 /601 X 34 = 1 743 chedule Air Sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,955 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 578 X 3001 Btuh/occ. / 100 sgft/occ. = 1734 Receptacle 1 o x x0.0001 Watts;/sqft x 1 3 41 1 Btuh/Watt = rocess 1.00 x 578 X 0.000 Watts/sqft x 3.413 Btuh/VWatt = 0 Infiltration:L x 73 X� x x D 5 / 6] x chedule Air Latent Area Ceiling Height ACH InM ROOM COOLING COIL LOADS 7 . Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 107 Time of Peak Jul 3 pm Floor Area 405 Outdoor Dry Bulb Temperature 112 O Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 78 Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window U -Value 1 0.07401 DETD 1 X X X X X X X X X 36.8 = = = = = = = = 24.5 24.5 24.5 37.1 55.1 = = = = = = Q 24.0 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X x X X X X X Factor = = = = = = Q 24.0 4 0.590 1.116 (E) 48.0 41 0.590 1.116 (E) 24.0 41 0.590 1.116 Page Total Btu/hr 256 341 682 341 576 775 2 971 Btu/hr 648 1,296 648 2,593 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 405 X 1.378 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 1,904 ccu ants 1.0 X 405 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 1,215 Receptacle 1.0 X 405 X 0.500 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 691 rocess 1.0c X 405 X 0.000 Watts/sqft X 3.41 Btuh/Waft x 1.�00 = 0 Infiltration: 1.00 X 1.064 X 405 X 10.00 X 0.50 /601 X I 341 = 1 221 chedule Air Sensible Area Ceiling Height ACH — T� Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,595 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 405 X 3001 Btuh/occ. / 100 sgft/occ. = 1 215 Receptacle 1.00 x x 0000 Watts/sgft x Btuh/Watt = rocess 1.00 X 405 -X 0.0001 Watts/sgft x 1 3.4131 Btuh/Watt = o Infiltration: xx x x � / 60] x ®_ chedule Air Latent Area Ceiling Height ACH pH► ROOM COOLING COIL LOADS .:Project Title Date Calle Estado, LLC 1 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 201 Time of Peak Jul 3 pm Floor Area 619 Outdoor Dry Bulb Temperature 112 OP - Indoor Dry Bulb Temperature 78cl� Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.24.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.24.16 Area X X X X X X X X X U -Value X X X X X X X X X 619.0 0.0360 139.0 0.0740 120.0 0.5800 64.0 0.0740 36.0 0.5800 124.0 0.0740 36.0 0.5800 286.0 0.0740 24.0 41 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. - Solar Gain Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Window (N) 24.0 41 0.590 Window (N) 48.0 41 0.590 Window (N) 24.0 41 0.590 Window (NE) 36.0 41 0.590 'ndow (E) 36.0 41 0.590 aJindow (S) 24.0 42 0.590 DETD 1 70.3 = 34.4 = 24.5 = 35.8 = 24.5 = 36.8 = 24.5 = 37.1 = Page Total Weighting Factor X 0.876 = X 0.876 = x 0.876 = X 1.274 = X 1.594 = X 0.868 = X X = X X Page Total Btu/hr 1,566 354 1,704 170 511 338 511 785 5 939 Btu/hr 509 1,018 509 1,110 1,388 516 5 049 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 619 X 1.052 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,222 ccu ants 1.0c x 619 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,857 Receptacle 1.0 X 619 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,056 rocess 1.0 X 619 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 619 x 10.00 x 0.50 /601 x 34 = 1 866 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,990 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 619 X 3001 Btuh/OCC. / 100 sgft/occ. = 1 857 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = Process 1.00 X 619 X 0.000 Watts/sgft X 3.413 Btuh[Watt = o Infiltration: x x x x�/ 6] x o oo2sz = chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Project Title ROOM INFO Room Name le Estado, LLC Floor Area Indoor Dry Bulb Temperature Conduction -30 Roof R.30.2x12.16 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Floor Assembly Suite 202 1 Time of Peak 728 Outdoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window "' indow U -Value Date 6/13/2007 DETD 1 70.3 = 34.4 = 24.5 = 36.8 = 37.1 = 24.5 = 28.6 = Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = (N) 24.0 41 0.590 0.876 _(M 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 30.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Jul 3 pm 112 78 Btu/hr 1,842 163 1,704 545 414 426 297 5 391 Btu/hr 509 1,018 509 645 516 3,196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor. Btu/hr i hts 1.0 X 728 X 1.022 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c X 728 X 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 2,184 Receptacle 1.0 X 728 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,242 rocess 1.0 X 728 x 0.000 Wafts/sgft X 3.41 Btuh/Watt X �1�00 = 0 Infiltration: 1.00 X 1.064 X 728 X 10.00 X 0.50 /601 X I 341 = 2 195 chedule Air Sensible Area Ceiling Height ACH T — Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,748 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 728 X 3001 Btuh/OCC. / 100 sqft/occ. = 2184 ece tale 1.00 x x 0,000j Watts/sqft x Btuh/Watt = rocess 1.00 x 728 x 0.000 Watts/sgft X 1 3.4131 Btuh/Watt = o Infiltration: x 47 x x x = /60 x chedule Air Latent Area Ceiling Height ACH pW i. ROOM COOLING COIL LOADS Project Title Date } Calle Estado, LLC I 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 203 Time of Peak Jul 3 pm Floor Area 781 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted 19 Wall .19.2x6.16 -19 Wall .19.2x6.16 olid Wood Door 19 Floor Assembly Area 781 1 266.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow U -Value 0.0360 0.0740 X X X X X X X X X DETD 1 = = = = = = = = = 70.3 34.4 24.5 37.1 55.1 52.9 28.6 24.0 41 Page Total Orientation Area X X x X X x X X X x SGF X X x X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 30.0 42 0.590 0.868 Page Total Btu/hr 1,976 341 2,130 483 1,493 1,842 282 8 548 Btu/hr 509 1,018 509 516 645 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 781 X 1.273 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 3,392 ccu ants 1.0c X 781 x 300 Btuh/OCC. / 10 sqft/occ. X 1.00 = 2,343 Receptacle 1.0 X 781 X 0.500 Watts/sqft x 3.41 Btuh[Watt x 1.00 = 1,333 rocess 1.0 X 781 x 0.000 Watts/sgft X 3.41 BtuhlWatt X 1.00 = 0 Infiltration: 1.00 X 1.064 X 781 X 10.00 X 0.50 /6] X 34 = 2355 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,167 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 781 X 3001 Btuh/OCC. / 100 sgft/occ. = 2 343 Receptacle 1.00 x x 0 0001 Watts/sgft x Btuh[Watt = Process 1.00 X 781 X 0.000 Wafts/sgft x -3.413 Btuh/Watt = 0 Infiltration: x x 781 x x / 6] x_ chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS roject Title Date j Calle Estado, LLC I 6/13/2007 Room Name Suite 204 Time of Peak Jul 3 pm Floor Area 860 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 78tk Outdoor Wet Bulb Temperature 78 `F Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Solid Wood Door 19 Wall .19.2x6.16 -19 Floor Assembly Area 860.0 X 134.0 X 150.0 X 366.0 X 24.0 X 246.0 X 266.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow U -Value 1 0.07401 DETD 1 X X X X X X X X X 70.3 = = = = = = = = = 34.4 24.5 36.8 30.8 37.1 28.6 (N) 24.0 Page Total Orientation Area X X X X X X X X X X SGF X x X X X X x X X X SC Weighting X x X X X X x X X X Factor = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 30.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Btu/hr 2,176 341 2,130 997 1.07 675 282 7 672 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 x 860 x 1.264 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 3,709 ccu ants 1.0c x 860 X 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 2,580 Receptacle 1.0 x 860 X 0.500 Watts/sgft x 3.41 Btuh[Watt x 1.00 = 1,468 rocess 1.0 x 860 x 0.000 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 860 x 10.00 x 0.50 /601 X 34 = 2 593 chedule Air Sensible Area Calling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,219 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 860 x 3001 Btuh/occ. / 100 sgft/occ. = 2 580 Receptacle 1.00 x x Watts/sgft x 3.413 Btuh/Watt = Process 1.00 x s6o x 0.000 Watts/sgft xj 3.413 Btuh/Watt = o - Infiltration: �� x Alr x Area � x Ceiling Heig10 ht x ACH CH / s] x zslw ROOM COOLING COIL LOADS 71 P_ roject Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 205 Time of Peak Jul 3 pm Floor Area 1,733 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 789F Outdoor Wet Bulb Temperature 78 Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 ouble Non Metal Tinted 19 Wall W.19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Floor Assembly Area 1,733.0 188.0 240.0 95.0 30.0 307.0 25.0 510.0 263.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow •- i indow Window Window Window U -Value 0.0360 0.0740 0.5800 0.0740 0.5800 0.0740 0.5800 0.0740 0.0370 X X X X X X X X X DETD 1 = = = = = = = = = 70.3 34.4 24.5 36.8 24.5 37.1 24.5 55.1 28.6 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = = c = _(M 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (N) 24:0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 4 0.590 0.876 (E) 30.0 4 0.590 1.270 (S) 48.0 42 0.590 0.868 (S) 25.0 42 0.590 0.868 Page Total Btu/hr 4,385 479 3,408 259 426 843 355 Y080 279 12 513 Btu/hr 509 1,018 509 509 1.018 509 922 1,032 538 6 562 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 1,733 x 0.939 Wafts/sgft x 3.41 Btuh/Watt X 1.000 = 5,556 ccu ants 1.0c X 1,733 X 300 Btuh/OCc. / 10 sgft/OCc. X 1.00 = 5,199 Receptacle 1.0 X 1,733 X 0.500 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 2,957 rocess 1.0 X 1,733 X 0.000 Watts/sgft X 3.41 Btuh/Watt x 1.00 = 0 Infiltration: r 1.00 X 1.064 X 1 733 X 10.00 X 0.50 /601 X 34 = 5 225 Schedule Air Sensible Area Calling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 38,013 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 1 733 X 3001 Btuh/occ. / 100 sqft/occ. = 5199 Receptacle 1.00 x x no Watts/sgft x Btuh/Watt = rocess 1.00 X 1,733 X 0.000 Wafts/sqft X 3.4131 Btuh/Waft = 0 t Infiltration: xX 1,72 x 10 D0 x / 60] x chedule Air Latent Area Ceiling Height ACH pW M ROOM COOLING COIL LOADS Project Title Date `� Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Aug 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 78 c Outdoor Wet Bulb Temperature 78 9F Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.24.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted Area 690.0 320.0 175.0 17.5 17.5 232.5 17.5 17.5 17.5 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value Orientation Area SGF (E) 65.2 17.5 X 36 (E) 24.5 17.5 X 36 (S) 17.5 X 70 (S) 17.5 X 70 (S) 17.5 X 70 (S) 17.5 X 70 (S) 17.5 x 70 (W) 16.0 X 5 (W) 48.0 X 5 16.0 X 5 0.0360 0.0740 0.0740 0.5800 0.5800 0.0740 0.5800 0.5800 0.5800 DETD 1 X X X X X X X X X 65.2 = = = = = = = = 33.5 35.9 24.5 24.5 41.7 24.5 24.5 24.5 SC X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 x 0.590 x 0.590 X 1 0.590 Page Total Weighting Factor X 2.078 = X 2.078 = X 1.112 = x 1.112 = X 1.112 = X 1.112 c x 1.112 = x 0.730 x 0.730 = X 1 0.730 Page Total Btu/hr 1,619 792 465 248 248 717 248 248 248 4 835 Btu/hr 772 772 804 804 804 804 804 351 1,054 351 7 319 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 690 X 1.078 Watts/sgft x 3.41 Btuh/Waft x 1.000 = 2,539 ccu ants 1.0 X 690 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 2,07 Receptacle 1.0 x 690 X 0.500 Watts/sgft x 3.41 Btuh/Waft X 1.00 = 1,177 rocess 1.0 x 690 x 0.000 Watts/sqft X 3.41 Btuh/Waft x 1.00 = 0 Infiltration: &S 1.00 x 1.064 x 690 x 10.00 x 0.50 1601 x 34 = 2 081 chedule Air Sensible Area Ceiling Height ACH QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,915 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 690 x 3001 Btuh/OCC. / 100 sgfUocc. = 2 070 Receptacle 1-00 x x 0 0001 Watts/sgft x Btuh/Watt = Process 1.00 x sso x 0.000 Wafts/sgft x 3.4131 BtuhlWatt = o Infiltration: 1 00 x x x x ��� /60] x o no2s2 = C� chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS (Project Title Date j Calle Estado, LLC 1 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Aug 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 112 C Indoor Dry Bulb Temperature 780F Outdoor Wet Bulb Temperature 78 9F Conduction Area U -Value DETD 1 Btu/hr Double Non Metal Tinted 17.5 X 0.5800 X 24.5 = 248 Double Non Metal Tinted 17.5 X 0.5800 X 24.5 = 248 -19 Wall .19.2x6.16 130.0 X 0.0740 X 55.0 = 529 Double Non Metal Tinted 16.0 X 0.5800 X 24.5 = 227 Double Non Metal Tinted 48.0 X 0.5800 X 24.5 = 682 Double Non Metal Tinted 16.0 X 0.5800 X 24.5 = 227 -19 Floor Assembly 690.0 X 0.0370 X 28.6 = 731 X X = X X = 1. Design Equivalent Temperature Difference (DETD) Page Total 2 893 Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Weighting Orientation Area SGF SC Factor x x x = X x x = x x x = x x x = x x x = x x x = X x x = x x x = x x x = x x x = Page Total Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts . 1.0c X 690 X 1.078 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c X 690 X 300 Btuh/OCc. / 10 sgft/occ. X 1.00 = 2,07 Receptacle 1.0 X 690 x 0.500 Watts/sqft x 3.41 Btuh[ Watt X 1.00 = 1,177 rocess 1.0c X 690 X 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration:1.00 x Sensible x 690 x 10.00 x 0.50 /601 x 34 = 2 081 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,915 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 690 X 3001 Btuh/OCC. / 100 sgft/occ. = 2 070 Receptacle 1.00 x x0,0001 Wafts;lsqft x Btuh/Watt = rocess 1.00 X 690 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 1 001 xx x x � / 6] x � f �-schedule Air Latent Area Ceiling Height ACH pW of Occupancy Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78-115 CALLE ESTADO STE #104 Use classification: COMMERCIAL (MORTGAGE ADVISERS) Occupancy Group: B Owner of Building: CALLE ESTADO LLC Building Official Type of Construction: VN IN A Building Permit No.: 07 2782 Land Use Zone: VC Address: 52-050 INDUSTRIAL WAY City, ST, ZIP: COACHELLA, CA 92236 By: STEVE TRAXEL Date: November 30, 2007