Loading...
07-2773 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00002773 - Property Address: 78115 CALLE ESTADO STE 203 APN: 770-152-010- - - Application description: REMODEL - COMMERCIAL Property Zoning: VILLAGE COMMERCIAL Application valuation: 5000 Applicant: T -tit. 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: �)IP. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: 814110 License No.: B Datr 0 Contractor! r OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work,. and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERM[1T VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/08/08 Owner: DEMAN RICHARD L 74140 EL PASEO.NO 377 PALM DESERT, CA 92260 Contractor: SANTA ROSA BUI RS, 78115 CALLE E O, LA QUINTA, CA 2 53 (760)972-6494 JAN r1 2008 Lic..NO.: B dMORAQUINTA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: ' Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I s_h rth 'th comply with those provisions. Date: r O A plicant, WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this co my o enter upon the above-mentioned propertyff sp�oses. Date: �O Signature (Applicant or Agent): f c ' Application Number . . . . . 07-00002773 ------ Structure Information SHELL SUITE 203 ----- Other struct info . . . . .. CODE EDITION O1BMP04E05EN FIRE SPRINKLERS YES MIXED-USE OCCUPANCY B OCCUPANT LOAD 18.00• --------------------------------------7------------------------------------- 2ND FLOOR SQUARE FOOTAGE 721.00 Permit BUILDING PERMIT Additional desc 721 SF OFFICE TI SUITE 203 Permit Fee 72.00 Plan Check`Fee 46.80 Issue Date . . . . Valuation . . . . 5000 Expiration Date 4/27/08 Qty Unit Charge Per Extension BASE FEE 45.00 3.00 9.0000 ---------------------------------------= THOU -BLDG 2,001-25,000 ------------------------------------ 27.00 Permit. . . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 16.50 Plan Check Fee 4.13 Issue Date . . . . Valuation . . . . 0 Expiration.Date 4/27/08 Qty. Unit Charge Per -Extension BASE FEE 15.00 2.00 .7500 ---------------------------------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 1.50 Permit MECHANICAL Additional desc . . Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date Valuation . . . . 0 Expiration Date 4'/27/08 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 4.5000 EA MECH VENT INST/ DUCT ALT - 9.00 --------------------------------------------------------------------------- Special Notes and Comments 721 SF CONSTRUCTION OFFICE T.I. "PRECISION ONE,ESCROW, INC." TYPE V -N "B" OCCUPANCY. 18 OCCUPANT LOAD. 2001 CBC,CMC, 2004 CEC, 2005 ENERGY CODES. ----------------------------------------------=------------------------=---- Other Fees ... . . . . . . .. ACCESSIBILITY PLAN REVIEW 4.68 LQPERMIT . Application Number .. . . . . 07-00002773 ---------------------------------------------------------------------------- Other Fees. . . . . . . . . . ENERGY REVIEW FEE 4.68 Fee summary Charged Paid Credited Due ----------------- .Permit Fee Total ---------- 112.50 -------------------- .00 ---------- .00 112.50 Plan Check Total 56..93. .00 .00 56.93 Other Fee Total 9.36 .00 .00 9.36 Grand Total 178..79 .00 .00 178.79 _ i r Bin # O�� City of La Quinta Building Safety & Safe Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # s ` Project Address: .70-057 AQC- SS AP -D Owner's Name: CALL& C-.jrAjD0 LLG A. P. Number: 770 .� S'Z _ O 4 D Q 9 Address: 5 2 - O,Sn 1, D VST (, W Legal Description. - City, ST, Zip: C 04GcIIZU-A G ?2Z39 Contractor: A V lL vC..✓`C S Telephone: 3 /.- �3 2V Address: Project Description: City, ST, Zip: C A %^ �/h,DiQdV �/t^C/`� . 7v Telephone: M .SU�T C Q l'lefC.�C.s State Lic. # : City Lic. #: Arch., Engr., Designer: AJ f C % f✓ �. ��/V T; L G {_.S (� N p �; _ _ Address: 7,F, /S CA 4(-a- _S1ADO ZJG 6GCR.0cj NG City, ST, Zip: A QU11J734 I GA 97Z33 Telephone: S/- V 70 Construction Type: Occupancy: State Lic: #: .5 Z 3 F3 7 G C Project type (circle one): New Add'n iter Repair Demo Name of Contact Person: 5 RE: 1 (5 N ca 7%0 Sq. Ft.: -/ Z / # Stories: # Units: Telephone # of Contact Person: S9 y— y70 Estimated Value of Project: ✓ , APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets 2i // Plan Check submitted b 10 Item Amount Structural Calcs. Reviewed, ready for o rections 10 00 Plan Check Deposit Truss Calcs. Called Contact Perso I v,�, I Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted 1 Mechanical Grading plan 2"" Review, ready for corrections/issue l ( Electrical Subcontactor List Called Contact Person (7- Plumbing _ Grant Deed Plans picked up S.M.I. ' H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee IL Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Certificate' of Occupancy T 44QUM& Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78-115 CALLE ESTADO STE 203 Use classification: COMMERICAL (PRECISION ESCROW, INC) Building Permit No.: 07-2773 Occupancy Group: B Owner of Building: RICHARD DEMAN Building Official • Type of Construction: VN Land Use Zone: VC Address: 74-140 PASEO #377 City, ST, ZIP: PALM DESERT, CA 92260 By: STEVE TRAXEL Date: January 24, 2008 P.O.*Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 To: Greg Butler, Building,& Safety Manager From: Les Johnson, Director -PDD Permit #: 07-2773 0 BUILDING & SAFETY DEPARTMENT (7 60) 777-7012 FAX (760) 777-7011 To PD: 10-17-07 Due Date: 10-24-07 Status: 1 st review Building Plans Approval (This is an approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: TENANT IMPROVEMENT / OFFICES - OCOTILLO BUILDERS Address or General Location: 78-115 CALLE ESTADO STE 203 Applicant Contact: STEVEN NIETO 564-4707 The Planning Development Department finds that: ❑ ...these Building Plans do not require Community Development Department approval. ...these Building Plans are approved by the Community Development Department. ❑ ...these Building Plans require corrections. Please forward a copy'of the attached corrections to the applicant. When the corrections are` made please return them to the Community Development Department for review. Les Johnson, Director -PD Date n To: City of La Quints Building Dept. 10/23/07 From: Calle Estado LLC Re: Tenant Improvement Contractor This letter is to notify the building department that Santa Rosa Builders, Inc. (#814110) will be contractor of record on 78-115 Calle Estado ( also known as Plaza Estado) Suite #'s 101, 102, 103, 104, 105, 106, 107, 203, 204, 205 Asaro Builders remains contractor of record on Suite # 206 Southwest Concepts (#523837) is contractor of record for Suites # 201 & 202. Thank You �I David Brudvik Partner Calle Estado, LLC (760)972-6494 October 22, 2007 Attn: Building Department C/o City of La Quinta 78-495 Calle Tampico . La Quinta, CA 92253 Project: Plaza Estado, 78-115 Calle Estado, La Quinta, CA 92253. RE:, Tenant Improvement Permits To Whom It May Concern, Asaro Builders, Inc. is hereby giving written notice to The City of La Quinta Building Department that we are NOT currently the "Contractor of Record" for the tenant improvements, for suites #201 & 202. Please remove are name from this permit. Additionally, please note we are NOT currently the "Contractor of Record" for suites #101, 102, 103, 104, 105, 106, 107, 203, 204 & 205. The only suite we ARE currently "The Contractor of Record" for, is suite #206 and we remain the "Contractor of Record" for the building shell. . We hope this clears up any confusion that may arise. Respectfully, Asaro Builders Inc. r Jim Huffman Sr. Project Manager cc: Stan Asaro File Ill OCT 222001 42-220 GREEN WAY, SUITE H, PALM DESERT, CA 92211, (760) 776-0043 FAX (760) 837-1049 SOUTH WEST CONCEPTS Architectural Design & Development 78-120 Calle Estado, Suite 206 La Quinta, CA 92253 Tel (760) 564-4707 City of La Quinta 78-495 Calle Tampico La Quinta, CA 92247-1504 Fax (760) 564-4955 October 4, 2007 Summary of Tenant Improvements at Plaza Estado Building The following is a chronological summary of the TI's and client list for the Plaza Estado building located at 78-115 Calle Estado, La Quinta, CA 92253 up to October 4, 2007. • 6/20/07 (Approximately) Submitted TI's for Suites 201 & 202 with client "South West Concepts" and for Suite 206 with client."Howard L. Rasch, Attorney at Law" • 7/6/07 Submitted TI's for Suite 106 with client "Salon W Beauty Parlor". • 7/19/07 Submitted TI's for Suite 105 with client "Leather & Shoes & More" and for Suite 104 with client "American Mortgage Advisers". • 7/24/07 First Review Plan check corrections for Suite 206 (Howard L. Rasch, Attorney at Law) received: • 7/26/07 First Review Plan.check corrections for Suite 106 (Salon W Beauty Parlor) received. There was anissue that came up with Community Development (additional parking spaces required) that made it impossible for this TI to continue. The Beauty Parlor pulled out. • 8/2%07 First Review Plan Check corrections for Suite 104 (American Mortgage Advisers) received. • 8/15/07.Suite 106 became available again because the Beauty Parlor pulled out. Then the whole situation changed and American Mortgage Advisers decided to take Suites 106 & 107, and they wanted a doorway between the two suites. Leather & Shoes & More decided to take Suites 104 & 105, and they wanted a pre-engineered and approved opening between the suites. Suites 201, 202, and 206 remained unchanged. • 8/20/07 (Approximately) TI's for suites 201 & 202 (South West Concepts) approved and permit pulled'. • 9/20/07 Submitted new TI's for Suites 104 & 105 (Leather & Shoes & More) and 106 & 107 (American Mortgage Advisers) • 10/1/07 TI's for suite 206 (Howard L. Rasch, Attorney at Law) approved and permit pulled. • 10/4/07 Three more sets of plans for Suites 104 & 105 submitted. One more set of plans for Suites 106 & 107 submitted. I TITLE 24 REPORT I ��1a•�Iy Gale � OCT 16 tom Title 24 Report for: Calle Estado, LLC Desert Club Dr. & Calle Estado La Quinta, CA 92253 +%e'saez;al Project Designer: South West Concects 78-120 Calle Estado, Suite 2 La Quinta, CA 92253 (760) 564-4707 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 6/13/2007 CITY OF LA QUINT'A BUILDING & SAF ETY APPROVE DEPT. FOR CONSTRUCTID oarF 2-7 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 1 I TABLE OF CONTENTS I J b Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM Envelope Mandatory Measures Form LTG -7-C Room, Cavity Ratio Worksheet Form OLTG-1-C Gertificate,"of Compliance.. " Form OL7G-2-C Lighting Compliance Summary Form OLTG-3-C Illuminated Area Calculation Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room .Load Summary Room Heating Peak Loads Room Cooling Peak Loads Room Cooling Coil Loads 1 2 3 27 28 29 31. 32 33 34 36 49 62 75 89 EnergyPro 4.3 by EnergySoft Job Number. User Number: 6712 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 _PROJECT NAME Calle Estado, LLC ROJECT ADDRESS Desert Club Dr. & Calle Estado La Quinta PRINCIPAL DESIGNER - ENVELOPE South West Concects DOCUMENTATION AUTHOR Scott Design & Title 24 TELEPHONE (760) 564-4707 200-4780 DATE 6/13/2007 GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR DATE OF PLANS DATE Tim Scott BUILDING CONDITIONED FLOOR AREA 9,048 Sq.Ft. CLIMATE ZONE 1 15 BUILDING TYPE ® NONRESIDENTIAL E] HIGH RISE RESIDENTIAL E] HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION E] ADDITION EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE Tim Scott The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. pF-] R 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ . El 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. R F-1 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE South West Concects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms LTG -1, LTG -2, LTG -3 PRINCIPAL LIGHTING DESIGNER - NAME He a Electrical Contractors SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE H & H Air Conditioning EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:3 of 102 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part of 3 PERF -1 -�� (N)Odeg ,PROJECT NAME Calle Estado, LLC 9,048 ANNUAL TDV ENERGY USE SUMMAR7 ENERGY COMPONENT Standard Design Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process 1.46 204.60 53.98 0.00 0.00 16.17 72.98 81.78 4.90 TOTALS: 435.87 Percent better than Standard: Proposed Compliance Design Margin 1.29 0.18 .194.26 10.34 57.67 -3.69 q 0.00 0.00 -0.14 -2.16 0.00 0.00 431.34 4.53 1.0% ( 1.1% excluding process) DATE' 6/13/2007 Building Orientation Number of Stories Number of Systems Number of Zones (N)Odeg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 9,048 sqft. sqft. sqft. 7- 2 0 14 5,402 131 Natural Gas Glazing Ratio Standard Proposed Lighting Power Density 1.100 wisgft. 1.133 wisgft. Prescriptive Env. Heat Loss 2,192 Muth 2,075 Btu/h Prescriptive Env. Heat Gain 226,727 Btum-F 217,905 Btum-F Remarks: Run Initiation Time: 06/13/07 13: EnergyPro 4.3 by EnergySoft User Number.•6712 Job Number. 4 of 102 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N 3,065 sqft. 1,260 sqft. 41.1% Left Elevation (E) 1,770 sqft. 233 sqft. 13.2% Rear Elevation s 3,135 sqft. 586 sqft. 18.7% Right Elevation (W) " Total Roof 1,870 9,840 5 411 sqft' sqft. sgft.sgft. 80 2,158 sqft. sqft 4.3% 21.9% 0.0% Standard Proposed Lighting Power Density 1.100 wisgft. 1.133 wisgft. Prescriptive Env. Heat Loss 2,192 Muth 2,075 Btu/h Prescriptive Env. Heat Gain 226,727 Btum-F 217,905 Btum-F Remarks: Run Initiation Time: 06/13/07 13: EnergyPro 4.3 by EnergySoft User Number.•6712 Job Number. 4 of 102 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERFA PROJECT NAME DATE Calle Estado, LLC 6/13/2007 LONE INFORMATION Floor Inst''.; FIr' Allowed LPi5a=:: Area LPD Credtfs ' A edT . ed Fonds' System Name Zone Name Occupancy Type (sgft.) (W/sf)1 .€ ;(Vllisfj?' IS3 Ps 4t III= Suite 101 Office 820 :.�_ 0.794 HVAC -4 Comp Bldg HVAC -2 Suite 102 Com Bldg Office P 91.289.1..� 433 n'F,p`ti ...-: F„ HVAC -2.5 Suite 103 Com BldgOffice 484 1.28 _ k .-,: K _ 4. +. 1 500 HVAC -2 Suite 104 Comp Bldg Office 484 1.28 ,. HVAC Suite 105 Comp Bldg Office 433 1.28 -2 HVAC 2.5 Suite 106 Com Bid Office 578 1.28 x r' w.:.. ' faf7 !''�� -' HVAC 2 Suite 107 Com BldgOffice 405 �j # Nak� 7z } f{ rf 3`: 1.37 t. t=._.�__-«":� 7��. ::i HVAC -3 Suite 201 Comp.Bldg Office 619 ._�'.-} .r; 1.052s,;..,r,-1):: HVAC -3 Suite 202 Comp Bldg Office 728 1.02. _.�+, .; ,� rt;. .,>�...�.[ �•! HVAC -3 Suite 203 Com BldgOffice 781 F.y..:,: t 1.27 t'� t � `5 ���I' .r 3:iiFl �ufri �T,1.'1.. 'iy 4�{:riA, 1T 7 HVAC4 Suite 204 Comp Bldg Office 860 1.26 HVAC -4 Suite 205 Comp Bldg Office 1,733 0.93 ;H: HVAC -3.5 Suite 206 Comp Bldg Office 690 1.07 • ii rlY.r,:.�?_r ii".7`� .1;.i�. 1,.. Notes: 1. See LTG -2-C 2. See LTGA-C 3. See LTG -5-C 4. See LTG -6-C Hems abpvreQulr�sp�ecal to ut�te�ntamti rL 3 e1 M;` (items marked with asterisk, see LTG -2 -C by others) (by others) fr._tf_ t. Cl�; EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency.determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Carrier 3BYRA02433" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 38YRA04833" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 38YRA03033" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0365" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0485" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50JX0423" includes Demand Control Ventilation per Standards Section 121. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and ncumentation for their use have been provided by the applicant Authorized Signature or Stam EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Pane:5 of 102 1 CERTIFICATE OF COMPLIANCE ENV -1-C NAME Calle Estado, LLC E SU DATE 6/13/2007 Surface # Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location 1 Comments 1 Wall 17E 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 101 2 Wall 64 0.074 R-19 R-0.0 45 90 New 09-A5 Suite 101 3 Wall ✓ 164 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 101 4 Wall J, 3461 0.074 R-19 R-0.01 180 90 New 09-A5 Suite 101 5 lWall 1 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 101 6 Wall 6 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 102 7 Wall 11 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 102 8 Wall / 13 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 103 9 Wall 18 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 103 10 Wall 24 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 103 11 Door 2 1.450 None R-0.01 270 90 New 28-A1 Suite 103 12 lWall 1341 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 104 13 Wall 26 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 104 14 Wall 18 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 104 15 Wall 6 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 105 16 Wall / 11 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 105 17 Wall 11 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 106 18 Wall 3 0.074 R-19 R-0.0 90 90 New 09 AS Suite 106 19 Wall 29 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 106 20 Wall 9 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 107 - N. E, A. R lMore than or equal to 10,000 sq.ft of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the building managers office after construction # Type Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments Window Front N 24 0.580 116-A 0.53 116-8 0 New Double Non Metal Tinted Suite 101 Window Front N 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 101 "3 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 101 4 Window Front N 36 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 101 5 Window Front NE 36 0.580 116-A 0.53 116-B 45 New Double Non Metal Tinted Suite 101 6 Window Left E 36 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 101 7 lWindow Rear S 20 0.5801116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 101 8 Window Rear S 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 101 9 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 102 10 Window Front N 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 102 11 Window Front N /, 24 0.580 116 -Al 0.53 116-B 1 0 New Double Non Metal Tinted Suite 102 12 Window Rear S 24 0.580 116 -Al 0.53 1116 -BI 180 New Double Non Metal Tinted ISuite 102 13 Window Rear S 25 0.580 116-A 0.53 116-B 1 180 New I Double Non Metal Tinted I Suite 102 ((1j U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 2 None 1 0.76 8.0 6.0 2.0 0.1 2.0 2.0 3 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 4 1 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 5 None / 0.76 6.0 6.0 2.0 0.1 2.0 2.0 6 None 0.76 6.0 6.0 2.0 0.1 2.0 2.0 7 None 0.76 5.0 4.0 10.0 0.1 10.0 10.0 8 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 9 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 10 None 0 0.76 8.0 6.0 2.0 0.1 2.0 2.0 11 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 12 INone 0.76 8.0 3.0 10.0 0.1 10.0 10.0 13 INone 0.76 5.0 5.0 10.0 0.1 10.0 10.0 1INIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W1112. See Section 143(c). If this box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach. 1 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page:6 of 102 1 CERTIFICATE OF COMPLIANCE ENVA -C JJ�ROJECT NAME DATE Calle Estado, LLC 6/13/2007 (OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 21 Wall 4 Window 21 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 107 22 Wall Window 19 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 107 23 Roof .46 Window 61 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 201 24 Wall 17 Window 13q 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 201 25 Wall 18 Window 6 0.074 R-19 R-0.0 45 90 _ New 09-A5 Suite 201 26 Wall 19 Window 12 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 201 27 Wall 20 Window 28 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 201 28 Roof 21 Window 72 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 202 29 Wall e 6 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 202 30 Wall i 20 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 202 31 Wall i 15 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 202 32 Floor / 28 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 202 33 Roof 26 lWindow 78 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 203 34 Wall 13 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 203 35 Wall 17 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 203 36 Wall 36 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 203 37 Door 2 1.450 None R-0.0 270 90 New 28-A1 Suite 203 38 Floor i 26 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 203 39 Roof 86 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 204 40 Wall 1 0.074 R-19 R-0.01 0 90 New 09-A5 Suite 204 -N. E.A.R F-1 More than or equal to 10,000 sq.fL of site -built fenestration area must Include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from Standards Table 116-A and R Cartif-te shall he filed In the contmdofs nmiect once durino construction and in the building mananers nflim after-t-dinn # Tvne Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 4 Window Front N r 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 103 Window Front N / 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 103 .46 Window Front N / 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 103 17 Window Rear S < 24 0.580 116-A 0.53 116-B 180 New . Double Non Metal Tinted Suite 103 18 Window Rear S 0.1 25 0.580 116-A 0.53 116-B 1801 New Double Non Metal Tinted Suite 103 19 Window Front N 21 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 104 20 Window Front N i 48 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 104 21 Window Front N / 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 104 22 Window Rear S None 25 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 104 23 Window Rear S 2.0 24 0.580 116-A 0.53 116-B 180 New I Double Non Metal Tinted Suite 104 24 lWindow Front N 24 0.580 116-A 0.53 116-B 0 New I Double Non Metal Tinted Suite 105 25 lWindow Front N 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted I Suite 105 26 lWindow Front N 24 0.580 116 -Al 0.53,116-B, 0 New Double Non Metal Tinted ISuite 105 (1) U -factor Type: 116-A Default Table from Standards, Table NIA Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 14 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 15 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 16 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 17 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0' 18 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 19 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 20 None 0.76 8.0 6.0 2.0 0.1 ' 2.0 2.0 ' 21 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 22 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 23 1 None 0.76 1 8.0 3.0 1 10.0 0.1 10.0 10.0 24 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 25 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 26 None 0.76 1 8.0 3.0 2.0 0.1 2.0 2.0 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is'in climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a i lighting of at least 0.5 Witt2. See Section 143(c). If this box is checked, ENV-" must be filled out. when submitting under the Pie: Oven llnifinfinn Ti- netts WrI7 4'i -9n -4n Dun t ^A -- height greater than 15 feet, and an LPD for general re Compliance Approach. EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Pane:7 of 102 1 CERTIFICATE OF COMPLIANCE ENVA -C NAME Calle Estado, LLC ACES DATE 6/13/2007 # Surface T e Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 41 Wall Window 36 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 204 42 Door Window 22 1.450 None R-0.0 90 90 New 28-A1 Suite 204 43 Wall 9Window 24 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 204 44 Floor / 26(.0.037 N R-19 R-0.0 0 180 New 20-A4 Suite 204 45 Roof 31 Window 1,73 0.036 R-30 R-0.0 0 0 New 02-A9 Suite 205 46 Wall i 180 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 205 47 lWall f 9 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 205 48 Wall 34 Window 301 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 205 49 Wall 35 Window 510 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 205 50 Floor 36 Window 261 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 205 51 Roof 37 Window 69 0.036 R-30 R-0.01 0 0 1 New 02-A9 Suite 206 52 Wall 38 Window 32 0.074 R-19 R-0.0 0 90 New 09-A5 Suite 206 53 Wall i 17 0.074 R-19 R-0.0 90 90 New 09-A5 Suite 206 54 Wall 23 0.074 R-19 R-0.0 180 90 New 09-A5 Suite 206 55 Wall 13 0.074 R-19 R-0.0 270 90 New 09-A5 Suite 206 56 Floor 691 0.037 R-19 R-0.0 0 180 New 20-A4 Suite 206 N. E. A, R (New, Existing. Altered, Removed) FENESTRATION SURFACES I�I More than or equal to 10,000 sq.R of site -built fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default 1.1 -factors from I 1 ,.,� 1-1- - . - o r -M -1e �n.0 h. fil.d In rr.o n i -f ..ff; a ,r ... ,,,. -4 i. rtio ..rr­ # Tvpe Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments Window Rear S 0.76 24 0.5801116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 105 Window Rear S 10.0 24 .0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 105 9Window Front N - 24'0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 30 Window Front N e 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 31 Window Front N 10.0 0.1 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 106 32 Window Left E None 24 0.580 116-A 0.53 116 -BI 90 New Double Non Metal Tinted Suite 107 33 lWindow Left E 2.0 48 0.5801116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 107 34 Window Left E 1 0.76 1 24 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 107 35 Window Front N 2.0 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 201 36 Window Front NI 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted I Suite 201 37 Window Front N 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 201 38 Window Front NE 36 0.580 116-A 0.53 116-B 45 New Double Non Metal Tinted Suite 201 39 Window Left (E) 36 0.580 116 -Al 0.53 116-B 1 90 New I Double Non Metal Tinted ISuite 201 1 U -factor Type: 115-A Default Table from Standanls, fable NI -1 Detault Table from the AGM Manual Appendix, NFRG Labeled value. 2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 27 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 28 None 0.76 5.0 5.0 10.0 0.1 10.0 10.0 29 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 30 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 31 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 32 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 33 None 0.76 8.0 6.0 10.0 0.1 10.0 10.0 34 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 35 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 36 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 37 1 None 1 0.76 8.0 3.0 2.0 0.1 2.0 2.0 38 1 None 1 0.76 1 6.0 6.0 2.0 0.1 2.0 2.0 39 1 None 1 0.76 1 6.0 6.0 2.0 0.1 2.0 2.0 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a calling height greater than 15 feet, and an LPD for general lighting of at least 0.5 Wfn2. See Section 143(c). If this box is checked, ENV -&C must be filled out when submitting under the Prescriptive Compliance Approach. .ten. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 102 1 CERTIFICATE OF COMPLIANCE ENVA -C PROJECT NAME DATE s Calle Estado, LLC 6/13/2007 Ll 10PAQUE SURFACES Surface Insulation Act. Cond: Joint Appendix # Tvne Area U -Fac. Cay. Cont. Azm. Tilt Status I IV Reference Location /Comments N. E, A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES F-jMore than or equal to 10,000 sq.ft of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Cerfificate using the default Ll -factors from Standards Tahle T 16-A and B. Cenifirata shall he filed in the contractors nmieet office dudno construction and in the building mananefs of na anwr rnnstnirtinn # Type Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments -�• Window Rear S None 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 201 Window Front N , 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 202 42 Window Front N 2.0 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 202 43 Window Front N 0.76 24 0.580 116-A 0.53 116 -BI 0 New Double Non Metal Tinted Suite 202 44 Window Rear S 0.1 30 0.580 116-A 0.53 116-B 180 New I Double Non Metal Tinted Suite 202 45 Window Rear S / 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 202 46 Window Front N / 24 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 203 47 Window Front N 4.0 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 203 48 Window Front N None 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 203 49 Window Rear S 2.0 24 0.580 116-A 0.53 116 -BI 180 New Double Non Metal Tinted Suite 203 50 lWindow Rear S / 30 0.580 0.53 116 -BI 180 New Double Non Metal Tinted Suite 203 51 Window Front N 1 -116-Al 24 0.580 116 -Al 0.53 116-Bil 0 New I Double Non Metal Tinted Suite 204 52[Window Front N 48 0.580 116-A 0.53 116 -BI 01 New I Double Non Metal Tinted Suite 204 1 Ll -factor Type: 115-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 1168 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 40 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 41 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 42 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 43 None 0.76 8.0 3.0 2.0 0.1 • 2.0 2.0 44 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 45 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 46 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 47 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 48 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 49 None 1 0.76 1 8.0 3.0 1 4.0 0.1 4.0 4.0 50 1 None 0.76 1 5.0 6.0 4.0 0.1 4.0 4.0 51 None 0.76 1 8.0 3.0 2.0 0.1 2.0 2.0 52 None 1 0.76 1 8.0 6.0 2.0 0.1 2.0 2.0 IINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES _ The proposed building Is in climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a r LA lighting of at least 0.5 W/ft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out when submitting under the Pre: D- Tlw.e, nCM4/n7 44.9n•4f1 Drrn C�r1e• greater than 15 feet, and an LPD for general EnergyPro 4.3 by Energy5oft User Number. 6712 Job Number: Page:9 of 102 1 CERTIFICATE OF COMPLIANCE ENV -1-C NAME Calle Estado, LLC DATE 6/13/2007 # Surface Insulation Act.Cond' Joint Appendix TvDe I Area I U -Fac. I Cay. Cont. Azm. Tilt Status I IV Reference I Location I Comments N. E, A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES �r-I1 More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from I I CI A- Takla 4IR_e nA A r`adifinafa shall ho filod In tha nnnfro fn?e nmiorl nffi­ d„rinn ..flet, Irlinn and in lha hl lilrllnn mananarc nffir agar mn.f lrlinn # 1Tvve Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments %3 Window Front N / 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 204 Window Rear S 4.0 30 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 204 5 Window Rear S 4.0 24 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 204 56 Window Front N 0.76 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 57 Window Front N 0.1 48 0.580 116-A 0.53 116-B 01 New Double Non Metal Tinted Suite 205 58 Window Front N 60 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 59 Window Front N 8.0 3.0 24 0.5801116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 60 Window Front N 4.0 48 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 61 Window Front N / 24 0.580 116-A 0.53 116-B 0 New Double Non Metal Tinted Suite 205 62 Window Left E 30 0.580 116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 205 63 Window Rear S 48 0.580 116-A 0.53 116 -BI 1801 New I Double Non Metal Tinted Suite 205 64 Window Rear S 25 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 205 65 Window Left E 18 0.580 116-A 0.53 1116 -BI 901 New I Double Non Metal Tinted I Suite 206 1 1.1 -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SFIGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhand Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 53 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 54 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 55 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 56 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 57 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 58 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 59 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 60 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 61 None 0.76 8.0 3.0 2.0 0.1 2.0 2.0 62 None 0.76 5.0 6.0 4.0 0.1 4.0 4.0 63 None 0.76 8.0 6.0 4.0 0.1 4.0 4.0 64 None 0.76 5.0 5.0 4.0 0.1 4.0 4.0 65 None 0.76 91NIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES IAThe proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 111:2, a ceiling height greater than 16 feet, and an LPD for general lighting of at least 0.5 Wfft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 10 of 102 CERTIFICATE OF COMPLIANCE ENV -1 -C] PROJECT NAME DATE 1 Calle Estado, LLC 6/13/2007 [OPAQUE SURFACES N. E. A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate elther issued by NFRC or provide a CEC Default Label Certificate using the default U -lectors from Claud -k Tahlp 11R -A and p r..,Iifi-ta shall hp filpd in the mntrarfnr_c nrniprt ntim ritirinn rnnstnirtinn and in thn huildinn mananprs nfrro nflpr rnnetnirtinn # TAm.e Area U -Fac' IV Reference Location Comments Act. A. Cond. Stat. GlazingType Location/ Comments A; Window Left E 18 0.5801116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 206 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 b8 Window Rear S 18 0.580 116-A 0.53 116-B 180 New . Double Non Metal Tinted Suite 206 69 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 70 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 71 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 72 [Window Right W 16 0.5801116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 73 Window Right 48 0.580 116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 74 Window Right W 16 0.580 116-A 0.53 116-8 270 New Double Non Metal Tinted Suite 206 N. E. A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate elther issued by NFRC or provide a CEC Default Label Certificate using the default U -lectors from Claud -k Tahlp 11R -A and p r..,Iifi-ta shall hp filpd in the mntrarfnr_c nrniprt ntim ritirinn rnnstnirtinn and in thn huildinn mananprs nfrro nflpr rnnetnirtinn # TAm.e Area U -Fac' SHGC2 Act. A. Cond. Stat. GlazingType Location/ Comments A; Window Left E 18 0.5801116-A 0.53 116-B 90 New Double Non Metal Tinted Suite 206 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 b8 Window Rear S 18 0.580 116-A 0.53 116-B 180 New . Double Non Metal Tinted Suite 206 69 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 70 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 71 Window Rear S 18 0.580 116-A 0.53 116-B 180 New Double Non Metal Tinted Suite 206 72 [Window Right W 16 0.5801116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 73 Window Right 48 0.580 116-A 0.53 116-B 270 New Double Non Metal Tinted Suite 206 74 Window Right W 16 0.580 116-A 0.53 116-8 270 New Double Non Metal Tinted Suite 206 j1)U-tactor type: l lb -A Uetaull ]able from Standards, Table NI -1 Default Table from the AGM Manual Appendix, NFRC Labeled Value. 2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 66 None 0.76 67 None 0.76 68 None 0.76 69 None 0.76 70 None 0.76 71 None 0.76 72 None 0.76 8.0 2.0 10.0 0.1 10.0 10.0 73 None 0.76 8.0 6.0 10.0 0.1 10.0 10.0 74 None 0.76 8.0 2.0 10.0 0.1 10.0 10.0 -1INIMUM SKYLIGHLARGE ENCLOSED SPACES _ T AREA FOR 1-1 The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a t lighting of at least 0.5 W1ft2. See Section 143(c). If this box is checked, ENV -0-C must be filled out. when submitting under the Pre: Run Initiation Time: 06/13/07 13:20:10 Run Code: EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. height greater than 15 feet, and an LPD for general re Compliance Approach. 11 of 102 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1-C [�-ROJECT NAME DATE Calle Estado, LLC 6/13/2007 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING.METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 10 248 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION I (Room #) CONTROL IDENTIFICATION CONTROLTYPE Time Switch, Dimm Check if SPACE CONTROLLED Daylighting INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 10,161 PORTABLE LIGHTING (From LTG -3-C) 87 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 10,248 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING.METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 10 248 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION I (Room #) CONTROL IDENTIFICATION CONTROLTYPE Time Switch, Dimm Check if SPACE CONTROLLED Daylighting CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1 -C PROJECT NAME —r I. Estado, LLC C 6/13/2007 esigner:alle This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: O LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing O LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page:13 of 102 1 CERTIFICATE OF COMPLIANCE MECH-1-C (PROJECT NAME DATE Calle Estado LLC 6/13/2007 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and oaeratino and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit -serves 5,000112 of space or less and 25% or more of the ducts are in noncondifioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace duds or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment re uiring acceptance testing EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:14 of 102 ]INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C I NAME Calle Estado, LLC POWER DATE 6/13/2007 Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description 03 CD �� c�i' 3 :�a,a °'.�� m ', o yv � 3fpa) vow �dc 3,in 3 ��� °'.off m m o c 3v � 3�`x m w co O f C) �m so c c Z 3• c o5'ag N m m =W .-w CD CL Yes Nn Metallux 2G-3-32ED 32T8 3 32 1.5 93.0 X 105 9.765 Metallux 6313 1 30 1.0 29.0 X 4 116 Portfolio C6032 F 32WGX24 -3 1 32 1.0 35.0 X 8 280 PAGE TOTAL 10 161 BUILDING TOTAL (sum of all pages) 10,161 PORTABLE LIGHTING (From LTG -3-C) 87 CONTROL CREDIT (From LTG -4-C) ADJUSTED ACTUAL WATTS 10 248 Run Initiation Time: 06113/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page: 15 of 102 PORTABLE LIGHTING WORKSHEET LTG -3-C NAME Calle Estado, LLC DATE 6/13/2007 STABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B C D ROOM # OR ZONE ID DEFAULT Wls ft AREA SF TOTAL WATTS B X C Suite 102 0.2 433 87 TOTAL WATTS (C x E) Suite 104 484 1 484 Suite 105 433 1 433 Suite 106 1 578 1 578 ite 107 1 405 1 405 TOTAL 433 87 TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B 7,744 C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 104 484 1 484 Suite 105 433 1 433 Suite 106 1 578 1 578 ite 107 1 405 1 405 iuite 201 619 1 619 Suite 202 728 1 728 Suite 203 781 1 1 781 Suite 204 860 1 860 TOTAL 4,888 0 ROOM # OR ZONE ID I TOT ISFREA Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types and mounting locations relative to work areas. TOTALS 0 BUILDING SUMMARY - PORTABLE LIGHTING TOTAL AREA (SF) TOTAL WATTS BUILDING SUMMARY (FROM TABLES 1+2+31 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 16 of 102 1 BUILDING TOTAL 7,744 87 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 16 of 102 1 PORTABLE LIGHTING WORKSHEET LTG -3-C ECT NAME Calle Estado, LLC DATE 6/13/2007 ITABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET I A B C D ROOM # OR ZONE ID DEFAULT /s ft AREA TOTAL WATTS SF B X C PORTABLE LIGHTING Description # OF FIXT. LUMIN. TASK # OF WATTS PER AREA TASK FIXTURE (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 205 1,733 1 1,733 Suite 206 690 1 690 TOTAL 0 0 TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B BUILDING TOTAL C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. TASK # OF WATTS PER AREA TASK FIXTURE (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite 205 1,733 1 1,733 Suite 206 690 1 690 TOTAL 2.423 0 ROOM # OR ZONE ID I OR (SFREA TOTAL[ 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details Include luminaire types and mounting locations relative to work areas. - BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TOTAL 7,744 87 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 17 of 102 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C LPROJECT NAME Calle Estado. LLC ISYSTEM FEATURES DATE 6/13/2007 AIR SYSTEMS, Central or Single Zone 8.60 HSPF 7.50 HSPF 7.70 HSPF 1 1 1 ITEM OR SYSTEM TAG(S) HVAC -4 HVAC -2 HVAC-2.5 of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification t Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation )uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 8.60 HSPF 7.50 HSPF 7.70 HSPF 112(a) 12.5 SEER / 10.8 EER 12.5 SEER / 10.9 EER 12.3 SEER / 10.7 EER 112(b) Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121 b 123 cfm 108 cfm 121 cfm 121 c No No No 121 c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Require Heating & Cooling Require 122 Auto Auto Auto 122( n/a n/a n/a 123 124 R-4.2 R-4.2 R4.2 144 a & b 144 n/a n/a n/a 144 a & b 29,355 btuh 14,990 btuh 18,737 btuh a & b n/a n/a n/a 144 a & b 29,312 btuh 17,616 btuh 21,538 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specifrcatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. I EneravPro 4.3 by EnergvSoft User Number: 6712 Job Number. Page:18 of 102 ' I MR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE 1 Calle Estado, LLC 1 6/13/2007 ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation }uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset AIR SYSTEMS, Central or Single Zone HVAC -2 HVAC -2 HVAC 2.5 1 1 1 Reference on Plans or Specification 1 112(a) 7.50 HSPF 7.50 HSPF 7.70 HSPF 112(a) 12.5 SEER / 10.9 EER 12.5 SEER / 10.9 EER 12.3 SEER / 10.7 EER 112(b) Yes Yes Yes 112(c), 115(a),n/a 18,790 btuh n/a n/a 121(b) Yes Yes Yes 121 b 121 cfm 108 cfm 144 cfm 121 c No No No 121 c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Re uired Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 Duct Sealing for Prescriptive Compliance 144 a & b n/a n/a n/a 144 a & b 14,990 btuh 14,990 btuh 18,737 btuh 144 a & b n/a n/a n/a 144 a & b 18,790 btuh 18,760 btuh 22,916 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144(f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. NOTES TO FIFI_D - Fnr Ruilrlinn DPnartmPnt tlse Only i'47. .IR r te? .F aT,, T�l.'1: �t. * 4 + itFt..+tl Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:19 of 102 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C JIT OJECT NAME Calle Estado, LLC ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation �uct Insulation PRESCRIPTIVE MEASURES DATE 6/13/2007 AIR SYSTEMS, Central or Single Zone HVAC 2 HVAC -3 HVAC -3 1 1 1 Reference on Plans or Specification 1 112(a) 7.50 HSPF 7.10 HSPF 7.10 HSPF 112(a) 12.5 SEER / 10.9 EER 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 112(b) Yes Yes Yes 112(c), 115(a), n/a n/a n/a 121(b) Yes Yes Yes 121 b 101 cfm 155 cfm 182 cfm 121 c No No No 121c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Require Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant -Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. 144 a & b n/a n/a n/a 144 a & b 14,990 btuh 21,860 btuh 21,860 btuh 144 a & b n/a n/a n/a 144 a & b 18,765 btuh 26,872 btuh 26,916 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No SIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C ECT NAME Calle Estado, LLC ITEM OR SYSTEM TAG(S) Number of Systems DATE 6/13/2007 AIR SYSTEMS Central or Single Zone HVAC -3 HVAC -4 HVAC4 1 1 2 T-24 MANDATORY MEASURES Section Reference on Plans or Specification 1 Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation )uct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43'2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 7.10 HSPF 7.20 HSPF 7.20 HSPF 112(a) 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 12.0 SEER / 10.5 EER 112(b) Yes Yes Yes 112(c), 115(a), n/a n/a n/a 121(b) Yes Yes Yes 121 b 195 cfm 215 cfm 433 cfm 121 c No No No 121c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Require Heating & Cooling Require 122 Auto Auto Auto 122 n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 21,860 btuh 29,355 btuh 58,710 btuh 144 a & b n/a n/a n/a 144 a & b 27,047 btuh 37,514 btuh 74,956 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144(f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. NOTES TO FIELD - For Building Department Use Only rtt Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 21 of 102 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C ECT NAME Calle Estado, LLC ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation �uct Insulation PRESCRIPTIVE MEASURES DATE 6/13/2007 AIR SYSTEMS, Central or Single Zone HVAC -3.5 1 Reference on Plans or Specification 1 112(a) 7.20 HSPF 112(a) 12.0 SEER / 10.4 EER 112(b) Yes 112(c), 115(a) n/a 121(b) Yes 121 b 172 cfm 121 c No 121 c Yes 121(c), 122(e) Programmable Switch 122(e) Heating & Cooling Required 122 Auto 122(g) n/a 123 124 1 R-4.2 Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < S,000 sqf : Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. 144 a & b n/a 144 a & b 25,607 btuh 144 a & b n/a 144 a & b 32,259 btuh 144 c Constant Volume 144 c 144 c Yes 144 d No 144 aE No Economizer 144 Constant Tem 144(f) Constant Temp 144 k No Kun Initiation Time: 06/13/07 13:ZU:1U Kun code: 1181766010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:22 of 102 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2. MECH-2-Cl PROJECT NAME DATE Calle Estado, LLC I 6/13/2007 Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 113 (a) 113 b 113 (c) 114 a E b (c) d AO SMITH ELJF-10 99% n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. 11VV r, CJ r V t -ICT TU - EnergvPro 4.3 by En( User Number. 6712 Job Number. of 102 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification' Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity 144 (a & b) Proposed Capacity 144 (a & b) Tower Fan Controls 144 h Tower Flow Controls 144 h Variable Flow System Design 144 (j) Chiller and Boiler Isolation 144 ' CHW and HHW Reset Controls 144 0) WLHP Isolation Valves 144 ' VSD on CHW, CW & WLHP Pumps > 5 144 0) HP DP Sensor Location 144 ' 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 113 (a) 113 b 113 (c) 114 a E b (c) d AO SMITH ELJF-10 99% n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. 11VV r, CJ r V t -ICT TU - EnergvPro 4.3 by En( User Number. 6712 Job Number. of 102 MECHANICAL VENTILATION MECH-3-C ECT NAME Calle Estado, LLC DATE 6/13/2007 PRESCRIPTIVE REHEAT LIMITATION Section 144(d)) MECHANICAL VENTILATION Section 121 (b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J I K L M N • ZONE/SYSTEM C1 D� �N o• pyo a otion �1T -n $ .. W`�9 xD� ndT z m3 V� Nm o c- �1T 7 `� m0 Xn n T1, -n v _ A �yO X C)o,� D n3CD wry' �a7 o 0 n�� Ty0 ��� y n �W y0 A c c w3nEi OLX ci rn 0. m= �C— in »� O� >> D y m D Suite 101 82C 0.15 123 123 123 HVAC -4 Total 123 123 Suite 102 43 0.15 65 65 108 HVAC -2 Total 65 108 Suite 103 484 0.15 73 73 121 HVAC -2.5 Total 73 121 Suite 104 484 0.15 73 73 121 HVAC -2 Total 73 121 uite 105 432 0.15 65 65 108 HVAC -2 Total 65 108 uite 106 57E 0.151 87 87 144 VAC 2.5 Total 87 144 Suite 107 40E 0.15 61 61 101 HVAC 2 Total 61 101 Suite 201 619 0.15 93 93 155 HVAC -3 Total 93 155 Suite 202 72E 0.151 109 109 182 HVAC -3 Total 109 182 Suite 203 78 0.15 117 117 195 HVAC -3 Total 117 195 Suite 204 860 0.15 129 129 215 HVAC -4 Total 129 215 Suite 205 1,732 0.15 260 260 433 HVAC,4 Total 260 433 Suite 206 69C 0.15 104 104 172 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load fore ress purposes fors aces without foxed seating. H Required Ventilation Air REQ'D V.A is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than ora ual to H or use Transfer Air column N to makeup the difference. J Design fan supply cfm Fan CFM x 30%: or K Condition area fl. sq.) x 04 cfmffL sq.: or L Maximum of Columns H, J, K or 300 cfrn M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 24 of 102 MECHANICAL VENTILATION MECH-3-C NAME Calle Estado, LLC DATE 6/13/2007 PRESCRIPTIVE REHEAT LIMITATION Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM n NDS a v�C 3 a 0 0 ro-A T'� °o W'<3 xD 09 T v >v Z m oQ �� o CD -n ��� `< m� x� 'T� T v 3 _ p�A off' p ;O D nim -n!►y �D� o 0 n� � -A ca ��0 v y n W y O x A 0 o w3 ski 07x Oyp "n= P. y � � V O '�' P —t ren •w m D HVAC -3.5 I Total 104 172 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seal or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be Areater than ore ual to H or use Transfer Air column N to make up the difference. J Design fan supply cfm Fan CFM x 30%; or K Condition area R sq.) x 04 cfmflt sq.; or L Max mumof Columns H, J. K, or 300 cfm M This must ba less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 25 of 102 ]MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C� PROJECT NAME Calle Estado. LLC DATE 6/13/2007 II 1 FR ^ENTRAL SYSTEM RATINGS Efficiency Tons PUMPS System Name System Type Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 2 5,120 10 New 0.95 n/a n/a 47,500 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 O.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 2 30,000 0.0 7.70 HSPF MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft No Economizer Control # HP Type In Plenum Outside DHW / BOILER SUMMARY ^ENTRAL SYSTEM RATINGS Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. O SMITH ELJF-10 Small Elec. All Pipes Ins 2 5,120 10 New 0.95 n/a n/a 47,500 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 O.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 2 30,000 0.0 7.70 HSPF MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft No Economizer Control # HP Type In Plenum Outside Buried Add 1/2" Insulation New No Economizer Carrier 50JX0485 Packaged DX 3 47,000 0.0 7.20 HSPFj 48,000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0423 Packaged DX 1 41,000 O.q 7.20 HSPF 41,500 12.0 SEER / 10.4 EER New INo Economizer ^ENTRAL SYSTEM RATINGS HEATING COOLING S stem Name System Type CIty Output Aux. kW Eff. output Eff iciencv Condition Status Economizer Type Carrier 3BYRA04833 Split DX 1 47,000 0.0 8.60 HSPF 47,500 12.5 SEER / 10.8 EER New No Economizer Carrier 38YRA02433 Split DX 4 24,000 O.0 7.50 HSPF 24,000 12.5 SEER / 10.9 EER New No Economizer Carrier 38YRA03033 Split DX 2 30,000 0.0 7.70 HSPF 28,600 12.3 SEER / 10.7 EER New No Economizer Carrier 50JX0365 Packaged DX 3 35,000 0.0 7.10 HSPF 35,000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0485 Packaged DX 3 47,000 0.0 7.20 HSPFj 48,000 12.0 SEER / 10.5 EER New No Economizer Carrier 50JX0423 Packaged DX 1 41,000 O.q 7.20 HSPF 41,500 12.0 SEER / 10.4 EER New INo Economizer CENTRAL SYSTEM AN SUMMARY UPPLY FAN TURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 38YRA04833 Constant Volume Draw -Through 1,600 0.50 76.0% 97.0% none Carrier 38YRA02433 Constant Volume Draw -Through 800 0.25 64.0% 97.0% none Carrier 38YRA03033 Constant Volume Draw -Through 1,000 0.33 64.0% 97.0% none Carrier 50JX0365 Constant Volume Blow -Through 1,200 0.33 64.0% 97.0% none Carrier 50JX0485 Constant Volume Blow -Through 1,600 0.50 76.0%1 97.0%1 none Carrier 50JX0423 Constant Volume Blow -Through 1,4001 0.50 76.0% 97.0% none Run Initiation Time: 06/13/07 13:20:10 Run Code: 1181 66010 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 26 of 102 ENVELOPE MANDATORY MEASURES ENV-MM NAME Calle Estado; LLC DATE 6/13/2007 DESCRIPTION Designer Enforcement RX §118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. RX § 118(c) All Insulating Materials shall be installed In compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. 0 §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. R §1`16(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). RX § 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. RX §118(e) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than RA3 between framing members. Energypro By EnergySoft User Number. User Job Number: Page:27 of 102 ]ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C NAME Calle Estado, LL .. bCUMENTATION AUTHOR ANG DATE A B C D E F Room Name Task/Activity Description Room Length (L) ft Room Width (\At) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 5xHx(L+W) /(LxW) A B C D E F Room Name Task/Activity Description Room Area (A) (sf) Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A 4.3 by Energy5oft User Number: 6712 Job Number: Page:28 of 102 CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C PROJECT NAME DATE Calle Estado, LLC 6/13/2007 rROJECT ADDRESS iL`' Desert Club Dr. & Calle Estado La Quinta PRINCIPAL DESIGNER -LIGHTING TELEPHONE 4UIId1►1Pern�t#aT;`?; Hegge Electrical Contractors (760) 775-4855 ;_. AUTHOR TELEPHONE aeeke . `:DOCUMENTATION OgU Scott Design & Title 24 (760) 200-4780 i_=�iforFernA` ei%lJ:a+ GENERAL INFORMATION DATE OF PLANS OUTDOOR LIGHTING ZONE LZ1 LZ2 [XJ LZ3 D LZ4 FUNCTION TYPE OUTDOOR LIGHTING �' OUTDOOR SIGNS F-1 INDOOR SIGNS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION O ADDITION F—] ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE Tim Scott The Principal Lighting Designer hereby certifies that the proposed outdoor lighting and signs design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146,and 149 of Title 24, Part 6. .Tease Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. F] I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. RE IDATE e Electrical Lltotl IINV I+VIVIt'LIHIVIa 1-VKIVIJ VVVKYllllCt 1 J UneeK box ItworKsneet Is included) ®OLTG-1-C: Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 maybe incorporated in schedules on the p Either LTG -1-C or OLTG-I-C may be used for signs as follows: 1. Use LTG -1-C if the project consists solely of indoor signs. 2. Use LTG -1-C if the project consists of indoor lighting, outdoor or indoor signs, but no other outdoor lighting. 3. Use OLTG-1-C if the project consists solely of outdoor signs. 4. Use OLTG-1-C if the project consists of outdoor lighting, outdoor or indoor signs, but no other indoor lighting. TG -2-C: LIGHTING COMPLIANCE SUMMARY. Applicable parts required for ALL outdoor lighting allowances (Except Signs). OLTG-3-C: AREA CALCULATIONS WORKSHEET. Applicable parts required for all outdoor area calculations. L]OLTG-4-C: SIGN LIGHTING COMPLIANCE. Required for all internally and externally illuminated signs, for both indoor and outdoor signs. I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:29 of 102 1 CERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-1-C NAME Calle Estado, LLC t' S h Jules on Plans Show that Outdoor Li htin Meets Allowed Li htin P DATE 6/13/2007 {_I 11 In t e ❑ Lighting power allowance for general site illumination on OLTG-2-C Part 1 of 4 ❑X Not Applicable ❑ Lighting power allowance for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4 ❑X Not Applicable ❑X Lighting power allowances for specific applications, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4 ❑ Not Applicable ❑ Lighting power allowances for vehicle service station canopies on OLTG-2-C part 4 of 4 ❑X Not Applicable ❑ Sign lighting compliance on OLTG-4-C ❑X Not Applicable Mandatory Measures on Plans Show that Outdoor Liahtinci Meets Outdoor Licititina Controls And Eauhment ❑X Installed lighting power has been determined in accordance with Section 130(c)1 ❑ Not Applicable ❑X All permanently Installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumins per Watt or are controlled by a motion sensor per Section 132(a) ❑ Not Applicable ❑X All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements of Section 132(b) Not Applicable ❑X All permanently installed outdoor lighting meets the control requirements of Section 132(c)l ❑ Not Applicable ❑X Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements of Section 132(c) ❑ Not Applicable CONTROL LOCATION (Room #) CONTROL CONTROLTYPE IDENTIFICATION (Auto Time Switch, Dimming, etc.) AREA CONTROLLED EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 30 of 102 1 LIGHTING COMPLIANCE SUMMARY (Part 3 of 4) OLTG-2-C Name Calle Estado, LLC Date 6/13/2007 LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS able 147-B - Other than Vehicle Station without Cano ies Allotted Watts Luminaire Lam s/Ballasts Desi n Watts A B C I D E F G H I J K L M N O P Lightingation (Table 147-B) a .. o -� �,y T �— ° l rma T c ry D o iR co xa n L9', 0 o a m Description v m y.0 m e �$ c� ' �r 4 m a3 m d C3 3 3� M. m r, 2) � 3F v m cd 3 y �» c� 3 �i m — m C) v r. r cc 3Zi- . 3 nim y 0? 3 N x0'�' f a D �o i O m pa o O f Ext Task 1,87 0.35 655 50w Low Voltage Halogen 50 Watt 1 50 1.0 54.0 X 432 43 Ext Task 27 38.50 10,626 50w Low Voltage Halogen WWatt 1 50 1.0 54.0 X 1 18 972 97 Lamp EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Paoe:31 of 102 1 ILLUMINATED AREA CALCULATION WORKSHEET (Part 3 of 5) OLTG-3-C PROJECT NAME DATE Calle Estado. LLC 6/13/2007 Outdoor Sales Lot and Sales Lot Area A B C D E F G H Gross Illuminated Area (sq. ft.) If an Outdoor Sales Frontage Allotment was used, subtract that area from the Gross Illuminated Area Overlapping Areas of Another Application Sales Lot Area (A - F - G) Mounting height of Sales Frontage Luminaires (feet) 3 x B Distance (In pla view) from the frontagge luminaire to fron edge of Sales Lot Sales Lot Frontage Length (feet) Sales Frontage Area (C - D) x E (sq. ft.) Area for which Illumination is Net Area Designated Name and Orientation Length Height Gross Area (B x C) Areas covered by signs Obstructed by Other Objects and Area Not Illuminated Sub total (E + F) Available for Facade Ligghtin (D -G? Ext Task 156 12 1.872 0 0 1.872 ❑ Section 147 (01 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. LJ Section 147 (c)2 B - Measured in plan view, only illuminated sections of outdoor sales frontage areas that are immediately adjacent to the principle viewing location and unobstructed viewing length, and are within 3 mounting heights of the frontage have been used. Luminaires qualifying for this allowance are located in plan view between the principle viewing location and the frontage sales. -11flBuildina Facade Area A B C D E I F I G H Areas (SF) to Subtract from within the Illuminated Area Area for which Illumination is Net Area Designated Name and Orientation Length Height Gross Area (B x C) Areas covered by signs Obstructed by Other Objects and Area Not Illuminated Sub total (E + F) Available for Facade Ligghtin (D -G? Ext Task 156 12 1.872 0 0 1.872 Checklist ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. Section 147 (c)2 A - Only facades areas that are illuminated without obstruction or interference, by one or more luminaires, have been used. EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Pane:32 of 102 1 LIGHTING MANDATORY MEASURES LTG-MM NAME DATE Calle Estado, LLC 6/13/2007 DESCRIPTION Designer Enforcement ❑X §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 0 §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. R§119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. 0 §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X❑ §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. a§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ❑ §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:33 of 102 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM (PROJECT NAME Calle Estado, LLC DATE 6/13/2007 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies a§111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. a§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated In accordance with Standards Section 123. a§ 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: ❑X § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours If power is interrupted; or §122(e)IB An occupancy sensor to control the operating period of the system; or F] § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. a§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: Page: 34 of 102 MECHANICAL MANDATORY MEASURES Part'2 of 2 MECH-MM NAME Calle Estado, LLC DATE 6/13/2007 Description Designer Enforcement Ventilation a§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. IAI § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or F] § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system is installed, It shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. a§ 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number: User Job Number. Page: 35 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC YSTEM NAME I HVAC -4 [Number of Systems 1 11 Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 47,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 47,000 57.3 Latent 47,500 47,500 4.0 57.9 207.2 DATE 6/13/2007 FLOOR AREA COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,613 22,363 3,743 1,097 15,174 0 1,118 759 0 0 123 4,888 1,0521 123 5,70 0 0 1,118 759 29,488 4,795 22 392 1,600 1,600 Carrier 38YRA04833 29,312 13,743 29,355 1.95 404.2 7 7 Total Adjusted System Output 28,312 13,743 29,355 (Adjusted for Peak Design Conditions) 0.15 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 66.2 of 83.4 of 83.4 OF Supply Air Ducts Outside Airt�, 123 cfm o Heating Coil Supply Fan 83.0 F 1600 cfm ROOMS 70.0 of 69.6 of �% Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0 / 77.9 of 77.5 / 66.2 of 60.3 / 59.4 of 60.3 / 59.4 of }�.-. Glia Supply Air Ducts O Outside Air E 4 123 cfm Cooling Coil Supply Fan 61.0 / 59.7 of 1600 cfm 61.6% R.H. ROOMS 74.7/65.0 of 74.0 / 64.8 OF Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Paae:36 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC (STEM NAME HVAC -2 Number of Systems . 1 Heating System Output per System 24,000 Total Output (Btuh) 24,000 Output (Btuh/sgft) 55.4 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 55.4 Total Output (sgft/Ton) 216.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.85 Airflow (cfm/Ton) 400.0 Outside Air (%) 13.5 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRICS 26.0 of 63.7 of Outside Air 108 cfm 69.6 OF DOLING SYS' 112.0 / 77.9 OF Outside Air 108 cfm 74.7/64.3 of EnerQyPro 4.3 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA COIL COOLING PEAK I COIL HTG. PEAK CFM Sensiblel Latent I CFM I Sensible 836 12,608 1,977 609 7,052 0 630 353 0 0 108 4,292 1,215 108 5,02 0 0 630 353 18,1621 3,191 12 779 irrier 38YRA02433 17,616 4,197 14,990 Total Adjusted System Output 17,616 4,197 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am im Temperatures at Time of Heating Peak) 81.3 of 81.3 of Heating Coil Supply Air Ducts ViE Supply Fan 80'9 OF 800 cfm ROOMS 70.0 OF Return Air Ducts I 79.8/66.40F ® 59.1 / 58.0 of User Number: 6712 of Cooling Peak) 59.1 / 58.0 of 13 > Supply Air Ducts Cooling Coil Supply Fan 59.8 / 58.3 of 800 cfm 58.6% R.H. ROOMS 74.0 / 64.0 OF I Return Air Ducts Job Number. of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 7NAME Calle Estado, LLC NAME HVAC -2.5 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airs! 26.0 of 64.2 of Outside Air 121 cfm Number of Systems 1 Heating System Output per System 3J62. Total Output (Btuh) 3 Output (Btuhlsgft) Cooling System Output per System 28,600 Total Output (Btuh) 28,600 Total Output (Tons) 2.4 Total Output (Btuh/sgft) 59.1 Total Output (sgft/Ton) 203.1 Air System CFM per System 1,000 Airflow (cfm) 1,000' Airflow (cfm/sqft) 2.07 Airflow (cfm/Ton) 419.6 Outside Air (%) 12.1 Outside Air 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 484 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 894 556 0 0 12 4,785 282 121 5,599 0 0 894 556 (cfm/sgft) 0.25 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airs! 26.0 of 64.2 of Outside Air 121 cfm Number of Systems 1 Heating System Output per System 3J62. Total Output (Btuh) 3 Output (Btuhlsgft) Cooling System Output per System 28,600 Total Output (Btuh) 28,600 Total Output (Tons) 2.4 Total Output (Btuh/sgft) 59.1 Total Output (sgft/Ton) 203.1 Air System CFM per System 1,000 Airflow (cfm) 1,000' Airflow (cfm/sqft) 2.07 Airflow (cfm/Ton) 419.6 Outside Air (%) 12.1 Outside Air 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 484 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,196 17,886 2,209 924 11,115 0 894 556 0 0 12 4,785 282 121 5,599 0 0 894 556 24,4651 3.59 F 17,8251 Carrier 3BYRA03033 21,538 4,356 18,737 Total Adjusted System Output21,538 4,356 18,737 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm an 12 am 'earn Temperatures at Time of Heating Peak) 81.8 of 81.8 of Heating Coil " Supply. Al r Ducts Supply Fan 81.3 of 1000 cfm ROOMS 70.0 of Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0 / 77.9 of 79.3 ! 66.2 of 59.1 / 58.0 of 59.1 / 58.0 of Supply Air Ducts Outside Air„ 121 cfm Cooling Coil Supply Fan 59.9 / 58.4 of 1000 cfm 58.4% R.H. ROOMS 74.8/64.2 of 74.0 ! 64.0 of Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:38 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Calle Estado, LLC 6/13/2007 STEM NAME FLOOR AREA I HVAC -2 484 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.65 Airflow (cfm/Ton) 400.0 Outside Air (%) 15.1 Outside Air (cfm/sgft) 0.25 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM Sensible 759 12,567 1,957 917 9,662 0 628 483 0 0 12 4,283 833 121 5,593 0 0 628 483 18,1071 2=7 16 22 Carrier 38YRA02433 18,790 3,870 14,990 Total Adjusted System Output 18 790 3,870 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Note: values above given at ARI conditions I I (EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 26.0 OF 62.9 OF 11 80.5 OF Outside Air 121 cfm 69.4 of PSYCHROMETRI 12.0 / 77.9 of Outside —�%—� 121 cfm 178.7 / 66.8 OF Heating Coil 80.5 of 0�Supply Air Ducts 1.F Supply Fan 79.9 OF 800 cfm ROOMS 70.0 OF Return Air Ducts I 83.8/68.7°F = 61.7/60.5°F Cooling Coil Supply Fa 800 cfm 61.7 / 60.5 OF —�j Supply Air Ducts Fan 62.4/60.7 OF 55.6% R.H. ROOMS 78.0 / 66.6 OF �% Return Air Ducts 4 I EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page:39 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC STEM NAME I HVAC -2 (Number of Systems 1 11 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating System Output per System 24,000 Total Output (Btuh) 24,000 Output (Btuh/sgft) 55.41 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 55.4 69.6 OF �OOLING SYSTEM 12.0177.9 OF Outside Air 108 cfm 78.6/66.4 °F DATE 6/13/2007 FLOOR AREA 433 COIL COOLING PEAK Total Output (sgft/Ton) 216.5 I Sensible Air System CFM CFM per System 800 Airflow (cfm) 800 0 Airflow (cfm/sgft) 1.85 3,843 Airflow (cfmlTon) 400.0 G. Outside Air (%) 13.5 Outside Air (cfm/sgft) 0.25 352 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Air: 26.0 OF 63.7 °F Outside Air 108 cfm 69.6 OF �OOLING SYSTEM 12.0177.9 OF Outside Air 108 cfm 78.6/66.4 °F DATE 6/13/2007 FLOOR AREA 433 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 628 10,857 1,75 607 7,030 0 543 352 0 0 108 3,843 895 108 5,02 0 0 543 352 15,786 2,646 12 754 r 3BYRA02433 18,760 3,696 14,990 Total Adjusted System Output 18,760 3,696 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am im i ei 81.3 OF Heating Coil Supply Fan 800 cfm 81.3 OF -� Supply.Air Ducts 80.9 OF ROOMS 70.0 OF h Return Air Ducts I 83.2 / 68.1 OF 61.1 / 59.9 OF v �bS Cooling Coil Supply Fa 800 cfm 61.1 / 59.9 OF Supply Air Ducts Fan 61.8/60.1°F 54.2% R.H. ROOMS 78.0166.2 OF JJ.,...... ) I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:40 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado LLC (STEM NAME HVAC 2.5 Airflow (cfm) 1]1.73 Airflow (cfm/sgft) ISensiblel Airflow (cfm/Ton) 4 Outside Air (%) 14.4 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions EATING SYSTEM PSY, 26.0 OF Outside Air 144 cfm 69.6 of DOLING SYS: 112.0 / 77.9 of Outside Air 144 cfm 78.6/66.9 of EnerovPro 4.3 63.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 578 COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 72 11,955 2,337 695 7,82 0 598 39 0 0 144 5,142 953 144 6,710 0 0 598 391 18,2991 3 290 15 313 irrier 38YRA03033 22,916 4,064 18,737 Total Adjusted System Output 22 916 4,064 18,737 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am im Temperatures at Time of Heating Peak) 80.90F 80.9 of Heating Coil s Qz' Supply Fan 1000 cfm Supply Air Ducts 80'6 OF ROOMS 70.0 of ETRICS (Airstream T 83.4 / 68.6 of User Number. 6712 �% Return Air Ducts 4 ?ratures at Time of Cooling Peak) 61.9/60.6OF 61.9/60.6OF a=L Supply Air Ducts Cooling Coil Supply Fan 62.4 / 60.8 of 1000 cfm 55.9% R.H. ROOMS 78.0 / 66.7 of Return Air Ducts < ' Job Number: of 102 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Calle Estado, LLC 6/13/2007 :(STEM NAME FLOOR AREA HVAC 2 405 .�........�.-.... a. i.. .'-wn nvr.��.w . ::A n [Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuhlsgft) Total Output (sgftlTon) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above alven at ARI conditions 26.0 OF Outside .�._� 101 cfm . 69.6 OF OOLING SYSTEM PSYCH 112.0 / 77.9 OF Outside Air 101 cfm 78.6 / 66.2 °F EnergyPro 4.3 by EnergySoft COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I ensible 59.3 I I TOTAL SYSTEM LOAD 15 25 2,5491 12 98 ovv 800 Carrier 38YRA02433 18,765 3,583 14,990 1.98 400.0 12 7 Total Adjusted System Output 18,765 3,583 14,990 (Adjusted for Peak Design Conditions) 0.25 TIME OF SYSTEM PEAK Jul 3pml an 12 am 64.0 OF 81.7 OF Heating Coil tures at Time of Heating Peak) 81.7 OF Supply Air Ducts Supply Fan 24,000 800 cfm -.Total Room Loads 60 10,595 1,638 632 7,534 24,000 Return Vented Lighting 0 59.3 Return Air Ducts 530 377 Return Fan o 0 24,000 Ventilation 10 3,597 91 101 4,693 24,000 Supply Fan 0 P 0 2.0 Supply Air Ducts 530 377 59.3 I I TOTAL SYSTEM LOAD 15 25 2,5491 12 98 ovv 800 Carrier 38YRA02433 18,765 3,583 14,990 1.98 400.0 12 7 Total Adjusted System Output 18,765 3,583 14,990 (Adjusted for Peak Design Conditions) 0.25 TIME OF SYSTEM PEAK Jul 3pml an 12 am 64.0 OF 81.7 OF Heating Coil tures at Time of Heating Peak) 81.7 OF Supply Air Ducts Supply Fan 81'2 OF 800 cfm ROOMS 70.0 OF Return Air Ducts I 82.8 / 67.9 °F M 60.8/59.60F User Number: 6712 Cooling Coil Supply Fa 800 cfm 60.8 / 59.6 of -� Supply Air Ducts Fan 61.4/59.8OF 53.5% R.H. ROOMS 78.0 / 66.0 OF h Return Air Ducts 'I Job Number: of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY .1'.-�-Calle Estado, LLC ,(STEM NAME 1 HVAC -3 CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfmisgft) 1.94 Airflow (cfmlTon) 411.4 Outside Air (%) 12.9 Outside Air (cfmisgft) 0.25 CNote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 64.0 of 64.0 of Outside Air 155 cfm 69.6 of DOLING SYSTE' 112.0177.90F Outside Air 155 cfm 78.7/66.9 OF EnergyPro 4.3 by Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 619 COIL COOLING PEAK I COIL HTG. PEAK CFM I Sen iblel Latent I CFM I Sensible 1,102 17,990 2,503 905 10,292 0 899 515 0 0 155 5,483 1,02 155 7,180 0 0 899 1 515 25,2771 3 524 18 50 Carrier 50JX0365 26,872 6,066 21,860 Total Adjusted System Output26,872 6,066 21,860 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am ream Temperatures at Time of Heating Peak) 81.10F Supply Fan Heating Coil 1200 cfm �% Return Air Ducts 14 83.0 / 68.5 of 83.0168.50F ® 62.0/60.80F Supply Fan Cooling Coil 1200 cfm User Number: 6712 Return Air Ducts Job Number. Supply Alr Ducts 80.7 of ROOMS 70.0 of Supply Air Ducts 62.7 / 61.0 of 55.9% R.H. ROOMS 78.0 / 66.7 of of 102 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Calle Estado, LLC 6/13/2007 STEM NAME FLOOR AREA I HVAC -3 728 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFMSensible 928 Latent I CFM I Sensible 1,070 16,748 2,944 928 9,629 0 837 48 0 0 182 6,458 888 182 8,449 0 0 837 481 24 88 3 83 19 04 Carrier 50JX0365 26,916 6,382 21,860 Total Adjusted System Output 26,916 6,382 21,860 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 63.0 of 63.0 of 80. �1oF O Supply Air Ducts Outside Air 182 cfm Supply Fan Heating Coil 79.7 of 1200 cfm ROOMS 69.6 of 70.0 of I 12.0 / 77.9 of Outside Air 182 cfm 78.7 / 67.4 of En2rgyPro 4.3 �% Return Air Ducts `i ROMETRICS (Airstream Temperatures at Time of Coolin 83.7 / 69.1 of 83.7/69.10F ® 62.6/61.40F Supply Fan Cooling Coil 1200 cfm User Number: 6712 Return Air Ducts Job Number: Supply Air Ducts 63.3 / 61.7 of 57.6% R.H. ROOMS 78.0 / 67.2 of 44 of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC STEM NAME I HVAC -3 lNumber of Systems Heating System Output per System 3 Total Output (Btuh) 3 Output (Btuh/sqft) Cooling System Output per System 3 Total Output (Btuh) 3 Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 62.4 OF 62.4 °F Outside Air 0,F 195 cfmv 69.5 of 12.0 / 77.9 of Outside Air 195 cfm 78.8/67.7 of 5,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 5,000 44.8 Latent 5,000 5,000 2.9 44.8 267.8 DATE 6/13/2007 FLOOR AREA 781 COIL COOLING PEAK 1COILHTG.PEAK CFMISensiblel 1,271 Latent 1CFM1 Sensible 1,408 21,167 3,158 1,271 12,278 0 1,058 614 0 0 195 6,893 760 195 9,043 0 0 1,058 614 30,176 3,918 7 22 549 1,200 1,200 Carrier 50JX0365 27,047 6,468 21,860 1.54 411.4 16.3 Total Adjusted System Output 27,047 6,468 21,860 (Adjusted for Peak Design Conditions) 0.25 9 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Airstream Tei 79.6 of Supply Fan Heating Coil 1200 cfm h - Return Air Ducts 4 ROMETRICS (Airstream Temperatures at 84.2 / 69.5 OF 84.2 / 69.5 of Irk 63.0 / 61.8 of Supply Fan Cooling Coil 1200 cfm h Return Air Ducts '� Supply Air Ducts 79.10F ROOMS 70.0 OF I Supply Air Ducts 63.9/62.1°F 58.6% R.H. ROOMS 78.0 / 67.5 of EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Paoe:45 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado, LLC ;!STEM NAME I HVAC -4 Total Room Loads turn Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts OTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 860 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 1,223 21,219 3,477 11145 12,939 0 1,061 647 0 0 215 7,637 1,796 215 9,98 0 0 1,061 647 30,9781 572741 24 214 Carrier 50JX0485 37,514 7,370 29,355 Total Adjusted System Output 37,514 7,370 29,355 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm an 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 63.8 of 63.8 of 81.0 of ,_ Supply Air Ducts Outside Air 215 cfm 80.6 OF Supply Fan Heating Coil 1600 cfm ROOMS 69.6 of 70.0 of :OGLING S 12.0 / 77.9 of >v Outside Air 215 cfm 78.6/66.4 of 4.3 Return Air Ducts PSYCHROMETRICS (Airstream Temperatures at 83.1 / 68.1 of 83.1/68.10F 61.1/59.80F Supply Fan Cooling Coil 1600 cfm User Number: 6712 Return Air Ducts Job Number: Supply Air Ducts 61.7 / 60.1 of 54.1% R.H. ROOMS 78.0166.2 OF of 102 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 1. PROJECT NAME Calle Estado, LLC . STEM NAME I HVAC -4 CFM per System 1,600 Airflow (cfm) 3,200 Airflow (cfm/sgft) 1.85 Alrflow (cfm/Ton) 400.0 Outside Air (%) 13.5 Outside Air (cfmisgft) 0.25 Note: values above given at ARI conditions ,ATING SYSTEM PSYCH 26.0 of 63.8 of Outside Air 433 cfm Supply Fan 3200 cfm 69.7 of COOLING SYSTEM PSYCH 112.0 / 77.9 of Outside Air 433 cfm 78.6/66.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/13/2007 FLOOR AREA 1.733 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,182 38,013 7,008 1,847 21,046 0 1,901 1,052 0 0 433 15,419 3,61 433 20,145 0 0 1,901 1,052 57,233 10,618 43 295 Carrier 50JX0485 74,956 14,815 58,710 Total Adjusted System Output 74,956 14,815 58,710 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am RICS (Airstream Tem 63.8 of g 81.0 of Heating Coil 83.1/68.1 Tem res Supply Air Ducts 80.7 of ROOMS 70.0 of Return Air Ducts I R'i 1 / rR 1oF ® r,1 1 / rq A of Supply Fan Cooling Coil 3200 cfm Supply Air Ducts 61.6 / 60.0 of 54.2% R.H. ROOMS 78.0 ! 66.2 of Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Pane:47 of 102 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Calle Estado LLC STEM NAME HVAC -3.5 FNGINEERING CHECKS Number of Systems 1 Heating System Output per System 41,000 Total Output (Btuh) 41,000 Output (Btuh/sgft) 59.4 Cooling System Output per System 41,500 Total Output (Btuh) 41,500 Total Output (Tons) 3.5 Total Output (Btuh/sgft) 60.1 Total Output (sgft/Ton) 199.5 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfmisqft) 2.03 Airflow (cfm/Ton) 404.8 Outside Air (%) 12.3 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0 of 64.2 of 64.2 of Outside Air N �'.r?°. . t 172 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts DATE 6/13/2007 FLOOR AREA COIL COOLING PEAK ICOILHTG.PEAK CFM Sensible Latent]ICFMI Sensible 1,348 22,915 2,790 1,104 12,869 0 82.9 / 68.0 OF 82.9 / 68,1 OF 61.2 / 60.0 OF 1,146 643 0 0 172 6,097 1,415 172 7,998 0 0 1,146 643 TOTAL SYSTEM LOAD 31 36 4 205 22 154 HVAC EQUIPMENT SELECTION Carrier 50JX0423 32,259 6,511 25,607 Total Adjusted System Output 32,259 6,511 25,607 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am ream Temperatures at Time of Heatina Peak) Supply Fan Heating Coil 1400 cfm 81.4 of h Return Air Ducts `i Supply Air Ducts 81.0 of ROOMS 70.0 OF I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112,0 177.9 OF 82.9 / 68.0 OF 82.9 / 68,1 OF 61.2 / 60.0 OF Supply Air Ducts �t Outside Air 172 cfm Supply Fan Cooling Coil 62.0 / 60.3 of 1400 cfm ROOMS 54.3% R.H. 78.8/66.5 of 78.0 / 66.2 of Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:48 of 102 ROOM LARD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -4 FLOOR AREA 820 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENTSuite SENSIBLE LATENT CFM SENSIBLE Suite 101 101 1 1,613 22,363 3,743 r1613 22,363 .31743 1 097 15,174 EnergyPro By EnergySoft User Number. User Job Number: Page:49 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -2 FLOOR AREA 433 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 102 Suite 102 1 836 12,608 1,977 836 12,608 1,977 609 7,052 .l PAGE TOTAL 1 836 12,608 1,977 609 7,052 TOTAL 1836 12,608 1,977 609 7,052 EnergyPro By EnergySoft User Number: User Job Number. Page, 50 of 102 6200M LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -2.5 FLOOR AREA 484 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENTSuite CFM SENSIBLE LATENT CFM SENSIBLE Suite 103 103 1 1,199 17,938 2,211 1,196 17,886 2,209 924 11,115 J PAGE TOTAL 1 1,196 17,886 2,209 924 11,115 TOTAL 1 1,196 17,886 2,209 924 11,115 EnergyPro By EnergySoft User Number. User Job Number. Page: 51 of 102 ROOM LOAD SUMMARY PROJECT NAME DATE Calle Estado, LLC 6/13/2007 .fSTEM NAME L HVAC -2 FLOOR AREA 484 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 104 Suite 104 1 759 12,567 1,957 759 12,567 1,957 917 9,662 EnergyPro By EnergySoft User Number: User Job Number: Page: 52 of 102 IROOM LOAD SUMMARY PROJECT NAME Cale Estado, LLC DATE 6/13/2007 ; STEM NAME HVAC -2 FLOOR AREA 433 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 105 Suite 105 1 628 10,857 1,751 628 10,857 1,751 607 7,030 EnergyPro By EnergySoft User Number. User Job Number. Page:53 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC 2.5 FLOOR AREA 578 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 106 Suite 106 1 725 12,022 1,943 721 11,955 2,337 695 7,821 PAGE TOTAL 1 721 11,955 2,337 695 7,821 TOTAL 1 721 11,955 2,337 695 7,821 EnergyPro By EnergySoft User Number: User Job Number: Page:54 of 102 FROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC 2 FLOOR AREA 405 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 107 Suite 107 1 601 10,595 1,638 601 10,595 1,638 632 7,534 PAGE TOTAL 1 601 10,595 1,638 632 7,534 TOTAL 101 10,595 1,638 632 7,534 EnergyPro By EnergySoft User Number: User Job Number. Page:55 of 102 ROOM LOA® SUMMARY L ' (PROJECT NAME Calle Estado, LLC VSTEM NAME HVAC -3 SE Suite 201 1.1021 17 DATE 6/13/2007 FLOOR AREA 619 PAGE TOTAL 1 11102 17,990 2,503 905 10,292 1 TOTAL 1 1,102 17,990 2,503 905 1Q292 EnergyPro By EnergySoft User Number: User Job Number. Page:56 of 102 FROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -3 FLOOR AREA 728 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 202 Suite 202 1 1,070 16,748 2,944 1,070 16,748 2,944 928 9,629 PAGE TOTAL 1 1,070 16,748 2,944 928 9,629 TOTAL 1 1,070 16,748 2,944 928 9,629 EnergyPro By EnergySoft User Number: User Job Number. Page:57 of 102 1200M LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -3 FLOOR AREA 781 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 203 Suite 203 1 1,408 21,167 3,158 1,408 21,167 3,158 1,271 12,278 PAGE TOTAL 1 1,408 21,167 3,158 F 1,271 F 12,278 TOTAL 1 1,408 21,167 3,158 1,271 12,278 EnergyPro By EnergySoft User Number: User Job Number. Page:58 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 STEM NAME HVAC -4 FLOOR AREA 860 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Suite 204 Suite 204 1 1,223 21,219 3,477 1,223 21,219 3,477 1145 12,939 ,J PAGE TOTAL 1 1,223 21,219 3,477 1,145 12,939 TOTAL 1 1,223 21,219 3,477 1,145 12,939 EnergyPro By EnergySoft User Number: User Job Number. Page:59 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE 6/13/2007 i STEM NAME HVAC -4 FLOOR AREA 1,733 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 205 Suite 205 1 2,182 38,013 7,008 2,182 38,013 7,008 1,847 21,046 EnergyPro By EnergySoft User Number. User Job Number: Page:60 of 102 ROOM LOAD SUMMARY PROJECT NAME Calle Estado, LLC DATE DATE6/13/2007 STEM NAME HVAC -3.5 FLOOR AREA 690 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM ISENSIBLE LATENT CFM SENSIBLE Suite 206 Suite 206 1 1,385 23,555 2,079 1,348 22,915 2,790 1,104 12,869 PAGE TOTAL 1 1,3481 22,915 2,790 1,104 12,869 TOTAL 1 1,348 22,915 2,790 1,104 12,869 EnergyPro By EnergySoft User Number. User Job Number. Page:61 of 102 a00M HEATING PEAK LOADS Project Title Date )aIle Estado LLC 16/13/2007 Room Information Desi n Conditions Room Name Suite 101 Time of Peak Jan 12 am Floor Area 820 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Ti Area 178.0 24.0 48.0 24.0 36.0 64.0 36.0 164.0 60 346.0 20.0 24.0 15.0 perimeter = 98.0 U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room: Page Total: 11 974 Infiltration: r 1.00 x 1.064 x azo x 10.0o x o.50o 160] x 44 = 3200 `schedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,174 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 62 of 102 ROOM HEATING PEAK LOADS Project Title Date `�q Estado, LLC 16/13/2007 Room Information Design Conditions Room Name Suite 102 Time of Peak Jan 12 am Floor Area 433 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 5 363 Infiltration: 1.001 x 1.064 x 433 x 10.00 x 0.500 / 6] x ® = 1 690 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,052 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:63 of 102 69.0 X X x X X X X X X X x X X x X X X x X x X x x x x X x x X x X X x X x X x x X 0.0740 X X X X X X X X X X X x x X x X x x x x x X X x x X X x X X x x X X x x X x X 44 = = = = = = = = = = = = 225 24.0 0.5800 44 612 48.0 0.5800 44 1,225 24.0 0.5800 44 612 116.0 0.0740 44 378 24.0 0.5800 44 612 25.0 0.5800 44 638 perimeter = 33.0 0.7300 44 1,060 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 5 363 Infiltration: 1.001 x 1.064 x 433 x 10.00 x 0.500 / 6] x ® = 1 690 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,052 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:63 of 102 ROOM HEATING PEAK LOADS project Title Date IMIP Fstado. LLC 16/13/2007 Room Information Desian Conditions Room Name Suite 103 Time of Peak Jan 12 am Floor Area 484 Outdoor Dry Bulb Temperature 26 of indoor Dry Bulb Temperature 70°F Double Non Metal Tinted Conduction Area U -Value R-19 Wall .19.2x6.16 134.0 X X X X X X X X X X X X X X X X X x x x x x x x x x x x x x x x x x x x x x x 0.0740 X X x X X X X X x X x X x X X X X X x x x x x x x x x x x x x x x x x x x x x Double Non Metal Tinted 24.0 0.5800 Double Non Metal Tinted 48.0 0.5800 Double Non Metal Tinted 24.0 0.5800 R-19 Wall (ZLI92x6`16) 181.0 0.0740 Double Non Metal Tinted 24.0 0.5800 Double 25.0 0.5800 R-19 Wall .19.2x6.16 241.0 0.0740 0 1,4500 Slab -On -Grade perimeter = 68.0 0.7300 1 F AT OF Btulhr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9.2261 Infiltration: r 1.00 1 x 1.osa x a8a x 10.0o x o.soo / 60] x 0 = 188s cheduie Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,115 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 64 of 102 ROOM HEATING PEAK LOADS Project Title Date Salle Estado, LLC 16/13/2007 Room Information Desi n Conditions Room Name Suite 104 Time of Peak Jan 12 am Floor Area 484 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 7 773 Infiltration: 1 1.001 x 1.064 x 484 x 10.00 x 0.500 / 6] x 0 = 1 889 chedule Air Sensible Area Ceiling Height ACH 6T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,662 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 65 of 102 134.0 X X X X X X X X X X x X X x X X X X X X X X X x x X X X X X x X X x X X X X X 0.0740 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x X X X X X 44 = = = = = = = = = = = = 436 24.0 0.5800 44 612 48.0 0.5800 44 1,225 24.0 0.5800 44 612 265.0 0.0740 44 863 181.0 0.0740 44 589 25.0 0.5800 44 638 24.0 0.5800 44 612 perimeter= 68.0 0,7300 44 2.184 Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 7 773 Infiltration: 1 1.001 x 1.064 x 484 x 10.00 x 0.500 / 6] x 0 = 1 889 chedule Air Sensible Area Ceiling Height ACH 6T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,662 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 65 of 102 ROOM HEATING PEAK LOADS Project Title Date Salle Estado LLC 16/13/2007 Room Information Desi n Conditions Room Name Suite 105 Time of Peak Jan 12 am Floor Area 433 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 5 340 Infiltration: r 1.00 X 1.064 X 433 X 10.00 X 0.500 / 6] X � = 1 690 `Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,030 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:66 of 102 69.0 X X X X X X X x X x x X X x X x x x X X X X X x X X X X X X X X X X X X X X X 0.0740 x X X x X X X X x X X x X X X X X X X X X X X X X X X X X X X x X X X X X X• X 44 = = = = = = = = = = = = = = = = = 225 24.0 0.5800 44 612 48.0 0.5800 44 1,225 24.0 0.5800 44 612 117.0 0.0740 44 381 24.0 0.5800 44 612 24.0 0.5800 44 612 perimeter = 33.0 0.7300 44 1,060 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 5 340 Infiltration: r 1.00 X 1.064 X 433 X 10.00 X 0.500 / 6] X � = 1 690 `Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,030 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:66 of 102 ROOM HEATING PEAK LOADS Project Title Date ��alle Estado LLC 6/13/2007 Room information Desicin Conditions Room Name Suite 106 Time of Peak Jan 12 am Floor Area 578 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X x X X X X X X X X X X X X X X X R-19 Wall W.19.24.16 114.0 0.0740 Double Non Metal Tinted 24.0 0.5800 Double Non Metal Tented 48.0 0.5800 Double Non Metal Tinted 24.0 0.5800 30.0 0.0740 -19 all .19.2416 290.0 0.0740 perimeter = 53.0 0.7300 AT o F Btu/hr Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 5565 Infiltration: r 1.001 X 1A64 X 578 X 10A0 X 0.500 / 6] X ® = 2 255 `Schedule Air Sensible Area Ce[ling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,821 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 67 of 102 ROOM HEATING PEAK LOADS Project Title Data 'calla Fctnrin I I C IR/iy9nu Room Information Desicin Conditions . Room Name Suite 107 Time of Peak Jan 12 am Floor Area 405 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F 48.0 Conduction Area U -Value 94.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0740 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 24.0 0.5800X 48.0 0.5800 24.0 0.5800 210.0 0.0740 190.0 0.0740 perimeter = 59.0 0.7300 AT of Btu/hr 306 612 1,225 612 684 619 1,895 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 5 953 Infiltration: r 1.00 X 1.064 X 405 X 10.00 X 0.500 / 60] X 44 = 1 580 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,534 EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 68 of 102 ROOM HEATING PEAK LOADS ...]project Title Date �InIliQ Fctnrin I I C; F;/13/7(1(17 Room Information Desicin Conditions Room Name Suite 201 Time of Peak Jan 12 am Floor Area 619 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF R-19 Wall .19.2x6.16 Conduction Area U -Value R-30 Roof R.30.2x12.16 619.0 x X X x X x X X X X X X X x x X X X X X X x X X X X X X X X X X X X X X X X X x Height 0.0360 X X X X X X X X X X x X X X X X x X X x X X X x X X X x X X X X x x X X x X X R-19 Wall .19.2x6.16 139.0 0.0740 nouble Non Metal Tinted 24.0 0.5800 Double Non Metal Tinted 48.0 0.5800 nniffilp Non Metal T4ntpri 24.0 0.5800 R-19 Wall .19.2x6.16 64.0 0.0740 Double o 36.0 0.5800 R-19 Wall .19.2x6.16 124.0 0.0740 Double Nnn Metal TWed 36 0,5800 -19 Wall .19 2x6.16 286.0 0.0740 Douhli, Non Mptnl Tinted 24.0 0.5800 Items shown with an asterisk (') denote conduction through an interior Infiltration: 1 1.001 x 1.osa x chedule Air Sensible Fraction surface to another room. s19 x 10.00 Area Ceiling o.500 / 60]x ACH AT of Page Total 44 AT Btu/hr 980 453 612 1,225 612 208 919 404 919 3 7 876 2 415 TOTAL HOURLY HEAT LOSS FOR ROOM 10,292 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page: 69 of 102 ROOM HEATING PEAK LOADS Project Title Date i.alla Fctarin I I C 8/13/2007 Room Information Desicin Conditions Room Name Suite 202 Time of Peak Jan 12 am Floor Area 728 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF R-19 Wall .19.2x6.16 Conduction Area U -Value R-30 Roof 8.30.2x12.16 728.0 X X X X X X X X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0360 X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X R-19 Wall .19.2x6.16 64.0 0.0740 Double 24.0 0.5800 Double Non Metal Tinted 48.0 0.5800 24.0 0.5800 R-19 Wall 9.2x6.16 200.0 0.0740 0N.19.26,16) 151.0 0.0740 Double Non Metal Tinted 30.0 0.5800 0,5800 R-1 9 Floor Assembly 280.0 0.0370 AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 6 788 Infiltration: r 1.00 X 1.064 X 728 X 10.00 X 0.500 160] X 44 = 2 841 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,629 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 70 of 102 ROOM HEATING PEAK LOADS Project Title }aIle Estado, LLC Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction uesl n Loonaitlons Suite 203 Time of Peak Jan 12 am 781 Outdoor Dry Bulb Temperature 26OF 70 of OT OF Btu/hr R-30 Roof R.30.2x12.16 . 781.0 X x X x X x X X X x x X X X X X X X X x X X X x x X X X X x X X X X X X X X X X Height 0.0360 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = 1.237 R-19 Wall .19.2x6.16 134.0 0.0740 44 436 nollble Non Metal Tented 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 24.0 0.5800 44 612 R-19 Wall 19.2x6.16 176.0 0.0740 44 573 d e Tinforl 24.0 0.5800 44 612 Double Non Metal Tinted 30.0 0.5800 44 766 60 0,0740 44 1.192 Solid Wood Door 24.0 1.4500 44 1,531 R-1 q Floor As,.;emhly 266.0 0.0370 44=433 Items shown with an asterisk (') denote conduction through an interior Infiltration: r 1.00 X 1.064 X `Schedule Air Sensible Fraction surface to another room. 781 X 10.00 Area Ceiling 0.500 / 6] ACH Page Total: 44 pT 9 230 3 048 TOTAL HOURLY HEAT LOSS FOR ROOM 127278 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number: Page: 71 of 102 ROOM HEATING PEAS( LOADS ]project Title Date Ialla Fctnrin I I C IR/1'1/9007 Room Information Desi n Conditions Room Name Suite 204 Time of Peak Jan 12 am Floor Area 860 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF R-19 Wall W.19.24.16 Conduction Area U -Value R-30 Roof R.30.2x12.16 860.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0360 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X R-19 Wall W.19.24.16 134.0 0.0740 r)oiible Non Metal Tented 24.0 0.5800 Double Non Metal Tinted 48.0 0.5800 nniihip NnI3 Metal Tinted 24.0 0.5800 R-19 Wall .19.24.16 366.0 0.0740 Soled Wood Door 24.0 1.4500 R-19 Wall .19.24.16 246.0 0.0740 Double Kinn Metal Tinted 0,5800 Double Non MetalTinted ___30.0 24.0 0.5800 R-1 A Finnr Assembly 266.0 0.0370 Z�T OF Btu/hr 1.3621 436 612 1,225 612 1,192 1,531 801 66 612 433 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9 583 Infiltration: r 1.00 1 X 1.064 X 860 X 10.00 X 0.500 16] X 44 = 3356 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,939 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page: 72 of 102 ROOM HEATING PEAK LOADS 71 Protect Title Date Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction Suite 205 Time of Peak 1,733 Outdoor Dry Bulb Temperature 70 of Area U -Value AT of Jan 12 am 26 of Btu/hr R-30 Roof R.30.2x12.16 1,733.0 X X X x X x X X X X X X X x X X X X X X X X x X X X X X X X X X X X x X X X X Height 0.0360 X X X X X X X X X X X X X X x X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = 2.745 R-19 Wall .19.2x6.16 188.0 0.0740 44 612 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 24.0 0.5800 44 612 Double Non Metal Tinted 24.0 0.5800 44 612 Double Non Metal Tinted 48.0 0.5800 44 1,225 Double Non Metal Tinted 24.0 0.5800 44 612 0 0,074 44= 309 Double Non Metal Tinted 30.0 0.5800 44 766 307.0 0.0740 44= Double Non Metal Tinted 48.0 0.5800 44 1,225 Double Non Metal Tinted 25.0 0.5800 44 638 R-19Wall .19.2x6.16 510.0 0,0740 44= 1,661 R-1 A Floor Assembly 263.0x 0.0370 44= Items shown with an asterisk (') denote conduction through an interior Infiltration: r 1.00 X 1.064 X schedule Air Sensible Fraction surface to another room. 1 733 X 10.00 Area Ceiling 0.500 / 6] ACH Page Total: 44 OT 14 283 6,762 TOTAL HOURLY HEAT LOSS FOR ROOM 21,oas EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number. Page:73 of 102 ROOM HEATING PEAK LOADS Project Title Date yalle Estado. LLC 6/13/2007 Room Information Desi n Conditions Room Name Suite 206 Time of Peak Jan 12 am Floor Area 690 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value 690.0 X X X x x X X x x x X X X X X X X X x X x X X X x X X X X X X X x X X X x X X 0.0360 X X x x X x x X x X X X X X x X X X x x x x X x X X X x X X X X X X X x X x X 320.0 0.0740 175.0 0.0740 17.5 0.5800 17.5 0.5800 232.5 0.0740 17.5 0.5800 17.5 0.5800 175 0,5B00 17.5 0.5800 17.5 0.5800 130.0 0.0740 16.0 0.5800 48.0 0.5800 6 0.5800 690.0 0.0370 AT of Btulhr items shown with an asterisk (`r) denote conduction through an interior surface to another room. Page Total: 1 O 176 Infiltration:) 1.00 x 1.os4 x sso x 10.0o x o.500 /60] x 0 = 2ss2 schedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7 12,869 EnergyPro 4.3 by EnergySoft User Number. 6712 Job Number. Page: 74 of 102 ROOM COOLING PEAK LOADS Title Date i Calle Estado, LLC I 6/13/2007 Room Name Suite 101 Time of Peak Jul 3 pm Floor Area 820 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 74CI7 Outdoor Wet Bulb Temperature 78 `k Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall W.19.2x6.16 R-19Wali .19.2x6.16 -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 24.0 4 0.590 (N) Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window N rth Glass Door Window Window indow d indow Window Window U -Value Orientation Area SGF 0.0740 0.5800 0.5800 0.0740 0.0740 0.0740 0.0740 DETD ' X X X X X X X X X 37.8 = = = = = = = = 27.9 27.9 39.2 40.1 40.2 58.2 4 0.590 SC (N) 24.0 X X X X X X X X x X 4 X X X X X X X X X x 0.590 X X X X X x X x X X (N) 48.0 4 0.590 (N) 24.0 4 0.590 (N) 36.0 4 0.590 (NE) 36.0 41 0.590 (E) 36.0 41 0.590 (S) 20.0 42 0.590 (S) 24.0 42 0.590 Page Total Weighting Factor 0.811 = 0.811 = 0.811 = 0.807 = 1.217 = 1.532 = 0.793 = 0.793 = Page Total Btu/hr 498 2,266 1,748 185 487 1,030 65 6 277 Btu/hr 471 942 471 703 1.060 1,334 393 471 5 845 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 820 x 0.794 Watts/sgft x 3.41 Btuh/Watt x 0.999 = 2,219 ccu ants 1.0 x 820 x 300 Btuh/occ. I 10 sgft/occ. x 1.00 = 2.46 Receptacle 1.0c x 820 x 1.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 2,799 rocess 1.0 x 820 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: '-Scneaule x Air Sensible x Area Ceiling x Ceiling He0lghOt x ACH 50 / 6] x QT 38 = 2 763 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,363 Sched. Btulhr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 820 x 300 Btuh/occ. / 100 sqft/occ. = 2 460 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = Process L1.00 X 820 X 0.000 Watts/sgft X 1 3.413 Btuh[Watt = 0 Infiltration:L 10o x 4L x E azn x E� x n 50 16] x _ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Title Date Calle Estado, LLC 6/13/2007 Room Name Suite 102 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 `F Indoor Dry Bulb Temperature 749F Outdoor Wet Bulb Temperature 78 `k Conduction Area 116.0 25.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. U -Value Solar Gain Orientation Area X X X X X X x X X X SGF X X X X X X X X X X SC Window (N) 24.0 41 0.590 Window (N) 48.0 41 0.590 Window (N) 24.0 41 0.590 indow (S) 24.0 42 0.590 indow (S) 25.0 42 0.590 - DETD 1 37.8 = 27.9 = 40.2 = 27.9 = Page Total Weighting Factor 0.811 = 0.811 = 0.811 = 0.793 = 0.793 = Page Total Btu/hr 193 1,942 345 405 2 885 Btu/hr 471 942 471 472 '491 2 847 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btulhr fights 1.0c X 433 X 1.289 Watts/sqft x 3.41 Btuh/Watt x 0.999 = 1,902 ccu ants 1.0 X 433 X 300 Btuh/occ. / 10C sgft/OCc. X 1.00 = 1,29 Receptacle 1.0 x 433 X 1.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 2,217 rocess 1.0 x 433 x 0.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 X 433 X 1 10.00 X 0.50 / 6] X 38 = 1 459 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,608 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 433 X 300 Btuh/OCC. / 1 1001 sgft/OCc. = 1 299 Receptacle 1 00 x x 0 pop Watts/sgft x 1 3 4131 Btuh/Watt = Process r-1.00 x 433 X 0.000 Watts/sgft x 1 3.413 Btuh/Watt = 0 Infiltration: x x _ 463 x x n 5Q / 6]w x In1= 67R �—schedule Air Latent Area Gelling Height ACH p ROOM COOLING PEAK LOADS Title Date N. Calle Estado. LLC 1 6/13/2007 1 m Name r Area or Dry Bulb Temperature Conduction -19 Wall W.19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Solid Wood Door Suite 103 484 740F Time of Peak Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Area X X X X X X X X X U -Value X X X X X X X X X 134.0 0.0740 120.0 0.5800 181.0 0.0740 25.0 0.5800 241.0 0.0740 24.0 1.4500 1.011 (N) 24.0 35 0.590 1.011 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow DETD 1 38.4 = 28.3 = 39.0 = 28.3 = 61.5 = 58.3 = Page Total Orientation Area X X x X X x X X X X SGF X x x x X x X x X x Sc Weighting X X x X X X X x X X Factor = = = = = = = (N) 24.0 35 0.590 1.011 (N) 48.0 35 0.590 1.011 (N) 24.0 35 0.590 1.011 (S) 24.0 33 0.590 1.071 (S) 25.0 33 0.590 1.071 Page Total Jul 4 pm 111 9F 78 '� Btu/hr 381 1,966 522 410 1,097 2,028 6 404 Btu/hr 501 1,002 501 500 521 3 025 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btulhr fights 1.0c x 484 x 1.285 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 2,123 ccu ants 1.0c x 484 x 300 Btuh/occ. / 10 sqft/occ. x 1.00 = 1452 Receptacle 1.0c x 484 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 826 rocess 1.0 x 484 x 1.500 Watts/sqft X 3.41 Btuh[Watt X 1.00 = 2,478 Infiltration: 1.00 X 1.064 x 484 X 10.00 X 0.50 /601 x 38 = 1 631 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,938 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 484 x 3001 Btuh/occ. / 100 sgft/occ. = 1452 Receptacle 1.00 x x 0.00 Watts/sgft x 3.413 BtuhlWatt = rocess 1.00 X 484 X 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: xx x x / 60] x ®_ chedule Alr Latent Area Ceiling Height ACH Zsw ROOM GAOLING PEAK LOADS ..Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 104 Time of Peak Jul 3 pm Floor Area 484 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 78 `k Conduction -19 Wall .19.2x6.16 ouble Non Metal Tinted -19 Wall (W.19.2x6.16) Area X X X X -X X X X X U -Value 134.0 0.0740 120.0 0.5800 265.0 0.0740 181.0 0.0740 25.0 0.5800 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain DETD 1 X X X X X X X X X 34.4 = = = = = = = - = 24.5 36.8 37.1 24.5 Factor = = = = = = - = = = N 24.0 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = - = = = N 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (S) 25.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Btu/hr 341 1,704 722 497 355 3 619 Btu/hr 509 1,018 509 538 516 3 089 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 X 484 X 1.285 Watts/sgft X 3.41 Btuh[Watt X 1.000 = 2,123 ccu ants 1.0 X 484 X 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 1,452 Receptacle 1.0 X 484 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 826 rocess Ledule 1.o x 484 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 484 x 10.00 x 0.50 /6]x Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,567 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 484 X 3001 Btuh/OCc. / 100 sqft/occ. = 1452 Receptacle 1 -on x x0 000� Watts/sgft x Btuh[Watt = Process 1.00 X 484 x 0.000 Watts/sgft x 3.413 BtuhfWatt = 0 Infiltration:L x x �_ x In oo x 0 56 l 6] x_ chedule Air Latent Area Calling Height ACH ply ROOM COOLING PEAK GOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 105 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 78 `k Conduction -19 Wall .19.2x6.16) Double Non Metal Tinted -19 Wall (W.19.2x6.16) Area 69.0 144.0 117.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window indow U -Value 1 0.07401 X X X X X X X X X DETD 1 = = = = = — — = = 34.4 24.5 37.1 Weighting X X X X X X X X X X Factor = = = = = = — = = = (N) 24.0 4 Page Total Orientation Area X X X X X X X X X X SGF X X X x x X X X x X Sc Weighting X X X X X X X X X X Factor = = = = = = — = = = (N) 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (S) 24.0 42 0.590 0.868 S 24.0 42 0.590 0.868 Page Total Btu/hr 176 2,045 321 2 541 Btulhr 509 1,018 509 516 516 3 067 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 433 x 1.289 Watts/sqft x 3.41 Btuh/Watt X 1.000 = 1,904 ccu ants 1.0c X 433 X 300 Btuh/OCC. / 10C sgft/OCc. X 1.00 = 1,299 Receptacle 1.0 X 433 X 0.500 Watts/sqft X 1.4V Btuh[Watt X 1.00 = 739 rocess 1.0c X 433 X 0.000 Watts/sgft X .3.4V Btuh/Watt X 1.001.00 = 0 Infiltration: 1.00 X 1.064 X 433 X 10.00 X 0.50 /601 X chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,857 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 433 x 300 Btuh/occ. / 1 1001 sgft/OCc. Receptacle 1.00 x x Watts/sgft x BtuhlWatt = Process 1.00 X 433 X 0.000 Watts/sgft X 3.413 Btuh/Watt = o Infiltration: xXE x !o Dn x 0 50 / 60] x ®= 45 chedule Air Latent Area Ceiling Height ACH pN/ ROOM COOLING PEAK LOADS (project Title Area X X x x x X X X X X SGF Date SC Calle Estado, LLC Factor = = = = = = = = = (N) 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS 0.733 (N) 48.0 Room Name Suite 106 Time of Peak (N) 24.0 Jun 5 pm Floor Area 578 Outdoor Dry Bulb Temperature 106 OF Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 74 C17 Conduction Area U -Value DETD 1 Btu/hr -19 Wall .19.2x6.16 114.0 X 0.0740 X 33.6 = 283 Double Non Metal Tinted 96.0 X 0.5800 X 21.3 = 1,188 19 Wall .19.2x6.16 30.0 X 0.0740 X 30.4 = 68 -19 Wall .19.2x6.16 290.0 X 0.0740 X 52.0 = 1,115 X X = X X = X X = X X = X X = 1. Design Equivalent Temperature Difference (DETD) Page Total 2,655 Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window indow Orientation Area X X x x x X X X X X SGF X X X x X x X X X x SC Weighting X X X x X x X x X X Factor = = = = = = = = = (N) 24.0 57 0.590 0.733 (N) 48.0 57 0.590 0.733 (N) 24.0 57 0.590 0.733 Page Total Btu/hr 591 1,183 591 2,366 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 578 X 1.287 Watts/sqft x 3.41 BtuhlWatt X 1.000 = 2,539 ccu ants 1.0 X 578 x 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 1,734 Receptacle 1.0 X 578 X 0.500 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 986 rocess 1.0c x 578 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 100 = 0 Infiltration: 1.00 x 1.064 x 578 x 1 10.00 x 0.50 /601 x I 341 = 1 743 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,022 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 578 x 300 Btuh/occ. / 100 sgft/occ. = 1 734 Receptacle 1.DD x x Watts/sgft x Btuh/Watt = Process 1.00 x 578 x 0.000 Watts/sgft x 3.413 BtuhlVUatt = o Infiltration: x XE 578 x Light x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Project Title Date L— Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 107 Time of Peak Jul 3 pm Floor Area 405 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 78 OF Conduction 19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window U -Value DETD 1 X X X X X X X X X 36.8 = = = = = = = = = 24.5 24.5 24.5 37.1 55.1 = = = = = = = (E) 24.0 Page Total Orientation Area X X x x X X X X XX X SGF X x X X X X X X X SC Weighting X X X x X X x x X X Factor = = = = = = = (E) 24.0 41 0.590 1.116 (E) 48.0 41 0.590 1.116 (E) 24.0 41 0.590 1.116 Page Total Btu/hr 256 341 682 341 576 775 2 971 Btu/hr 648 1,296 648 2,593 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr ights 1.0c x 405 X 1.378 Watts/sgft X 3.41 Btuh/Watt x 1.000 = 1,904 ccu ants 1.0 X 405 X 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,215 Receptacle 1.0 X 405 X 0.500 Watts/sgft X 3.41 Btuh[Watt X 1.00 = 691 rocess 1.0 X 405 X 0.000 Watts/sgft X 3.41 BtuhfWatt X 1.00 = 0 Infiltration: Ix 1.064 X 405 X 1 10.00 X 0.50 /601 x = 1 221 chedule Air Sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,595 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 405 x 300 Btuh/OCC. / 100 sgft/occ. = 1215 Receptacle 1.00 x x Q pop Watts/sqft x Btuh/Watt = Process 1.00 X 405 X 0.000 Watts/sgft x 1 3.4131 Btuhfwatt = 0 Infiltration:L x 4 77 x x x n SQ / 60] x_ chedule Air Latent Area Ceiling Height ACH &W ROOM COOLING PEAK LOADS Title Date Calle Estado, LLC 6/13/2007 iName Area r Dry Bulb Temperature Conduction -30 Roof 8.30.2x12.16 -19 Wall W.19.2x6.16 ouble Non Metal Tinted -19 Wall .19.24.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Suite 201 619 78`k Time of Peak Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Area X X X X X X X X X U -Value X X X X X X X X X DETD _ = = = = = = = 619.0 0.0360 74.2 139.0 0.0740 32.9 120.0 0.5800 23.2 64.0 0.0740 34.5 36.0 0.5800 23.2 124.0 0.0740 35.7 36.0 0.5800 23.2 286.0 0.0740 38.9 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area X X X x X X X X X X SGF X X X X X X X X X X SC (N) 24.0 46 0.590 LN, 48.0 46 0.590 (N) 24.0 46 0.590 (NE) 36.0 46 0.590 (E) 36.0 46 0.590 (S) 240 49 0.590 Page Total Weighting Factor X 0.773 = X 0.773 = X 0.773 = X 1.182 = X 1.510 = X 0.739 = x = X = X X = Page Total Jul 2 pm 111 78 9F Btulhr 1,654 338 1,612 163 483 327 483 823 5 886 Btu/hr 504 1,008 504 1,155 1,476 512 5 158 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 619 X 1.052 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,222 ccu ants 1.0c X 619 X 300 Btuh/OCc. / 10 sgft/OCc. X 1.00 = 1,857 Receptacle 1.0c X 619 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 1,056 rocess 1.0 x 619 x 0.000 Watts/sqft x 3.41 Btuh[Watt x 1.00 = 0 Infiltration:1.00 X 1.064 X 619 X 10.00 X 0.50 /601 X 1 34 = 1 866 Ledule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,046 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 619 X 3001 Btuh/occ./ 100 sgft/OCc. = 1 857 ece tacle 100 x x Watts/sqft x BtuhMatt = Process 1.00 x 619 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 Infiltration: x x x 10 on x � / 6] x ��p�3� _ chedule Air Latent Area Ceiling Height ACH ply ROOM COOLING PEAK LOADS Project Title Date } Calle Estado, LLC 6/13/2007 r ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 202 Time of Peak Jul 3 pm Floor Area 728 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 78°F Outdoor Wet Bulb Temperature 78 91F Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.24.16 Double Non Metal Tinted -19 Floor Assembly Area 728.0 64.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window dow U -Value 1 0.03601 DETD 1 Area X 70.3 = X 34.4 = X 24.5 = X 36.8 = X 37.1 = X 24.5 = X 28.6 = X = X = Page Total Orientation Area SGF X 41 x 41 X 41 X 42 X 42 X X X x X X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = = (N) 24.0 0.590 0.876 (,N) 48.0 0.590 0.876 (N) 24.0 0.590 0.876 (S) 30.0 0.590 0.868 (S) 24.0 0.590 0.868 Page Total Btu/hr 1,842 163 1,704 545 414 426 297 5 391 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c x 728 x 1.022 Watts/sgft x 3.41 Btuh/Watt x 1.000 = 2,539 Occupants 1.0c x 728 x 300 Btuh/occ. / 10 sqft/occ. x 1.00 = 2,184 Receptacle 1.0c x 728 x 0.500 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 1,242 rocess 1.0 x 728 x 0.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration:1.00 x 1.064 x 728 x 10.00 x 0.50 /601 x 34 = 2 195 Ledule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,748 Sched. Btulhr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 728 x 3001 Btuh/OCC. / 100 sgft/occ. = 2184 Receptacle 1.00 x x Watts/sgft x Btuh[Watt = Process 1.00 x 728 x 0.00PI Watts/sgft x 1 3.4131 Btuhfwatt = 0 Infiltration: x x 7aa x x A n50 l6] x [�n chedule Air Latent Area Ceiling Height CH 61WW ROOM COOLING PEAK LOADS (Project Title Date Calle Estado, LLC 6/13/2007 r%OOM INFORMATION DESIGN CONDITIONS Room Name Suite 203 Time of Peak . Jul 3pm Floor Area 781 Outdoor Dry Bulb Temperature 112 C� Indoor Dry Bulb Temperature 78OFOutdoor Wet Bulb Temperature 78 `F Conduction -30 Roof R.30.2x12.16 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall W.19.24.16 -19 Wall .19.24.16 Solid Wood Door -19 Floor Assembly Area 781 134 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 U3601 1 0.03701 Orientation Area X X X X X X x X x x SGF X X X x X X x X X x SC N 24.0 41 0.590 (N) 48.0 41 0.590 (N) 24.0 41 0.590 (S) 24.0 42 0.590 (S) 30.0 42 0.590 DETD 1 70.3 = 34.4 = 24.5 = 37.1 = 55.1 = 52.9 28.6 Page Total Weighting Factor X 0.876 = X 0.876 = x 0.876 = X 0.868 = X 0.868 = x = X = x X = x Page Total Btu/hr 1,976 341 2,130 483 1,493 1,842 282 8 548 Btu/hr 509 1,018 509 516 645 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 781 x 1.273 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 3,392 ccu ants 1.0c x 781 X 300 Btuh/occ. / 10C sgft/occ. X 1.00 = 2,343 Receptacle 1.0c X 781 X 0.500 Watts/sqft x 3.41 Btuh[Watt x 1.00 = 1,333 rocess 1.0 x 781 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 X 781 X 10.00 X 0.50 / 6] X � = 2 355 Schedule Air Sensible Area Ceiling Height ACH Zl�T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,167 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 x 781 X 3001 Btuh/OCC. / 100 sgft/occ. = 2343 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = Process 1.00 x 781 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: � x d�771 x Area x x � / 6] x InM = chedule Alr Latent Area Ceiling Height ACH pW I EneMVPro By EnergySoft User Number: User Page:84 of 102 1 ROOM COOLING PEAK LOADS Project Title Calle Estado, LLC ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction -30 Roof R.30.2x12.16) -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 olid Wood Door -19 Wall .19.2x6.16 -19 Floor Assembly Suite 204 1 Time of Peak 860 1 Outdoor Dry Bulb Temperature 78CI= Outdoor Wet Bulb Temperature Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value Date 6/13/2007 DETD 1 70.3 = 34.4 = 24.5 = 36.8 = 30.8 = 37.1 = 28.6 = Page Total Orientation Area X X X X X x x X X X SGF X X x X X X X x XX X SC Weighting X X X x x x x X X Factor = = = = = =. = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 30.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Jul 3 pm 112 OF 78 �: Btu/hr 2,176 341 2 130 997 1.07 675 282 7 672 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c X 860 X 1.264 Watts/sgft X 3.41 BtuhfWatt X 1.000 = 3,709 ccu ants 1.0 x 860 x 300 Btuh/occ. / 10sqft/occ. x 1.00 = 2,580 Receptacle 1.0c x 860 X 0.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 1,468 Process 1.0 x 860 x 0.000 Watts/sgft X 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 X 860 X 10.00 X F 0.50 /601 X 34 = 2 593 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,219 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 860 X 300 Btuh/occ. / 1 1001 sgft/occ. = 2 580 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = rocess 1.00 x 860 x 0.000 Watts/sgft x 3.413 Btuh[Watt = o Infiltration: x x=� x x / 60] x = 89 chedule Air Latent Area Ceiling Height ACH pW I EnemVPro By EnemySoft User Number: User Page:85 of 102 1 ROOM COOLING PEAK LOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 205 Time of Peak Jul 3 pm Floor Area 1,733 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 78 OF Conduction 30 Roof R.30.2x12.16 -19 Wall .19.24.16 Double Non Metal Tinted 19 Wall W.19.24.16 ouble Non Metal Tinted 19 Wall .19.2x6.16 ouble Non Metal Tinted -19 Wall .19.24.16 19 Floor Assembly Area 1,733.0 188.0 240.0 95.0 30.0 307.0 25.0 510.0 263.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 0.5800 0.0740 0.5800 0.0740 0.5800 0.0740 0.0370 DETD X X X X X X X X X 70.3 = = = = = = = = = 34.4 24.5 36.8 24.5 37.1 24.5 55.1 28.6 Page Total Orientation Area X X X X X X X X X X SGF X X X X X x X X X x SC Weighting x X X X X x x X X X Factor = = = = = = = = = (N) 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (EE) 30.0 4 0.590 1.270 (S) 48.0 42, 0.590 0.868 (S) 25.0 42 0.590 0.868 I I Page Total Btu/hr 4,385 479 3,408 259 426 843 355 2,080 279 12 513 Btu/hr 509 1,018 509 509 1,018 509 922 1 032 538 6,5621 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c x 1,733 x 0.939 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 5,556 ccu ants 1.0c x 1,733 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 5,199 Receptacle 1.0 x . 1,733 X 0.500 Watts/sgft X 3.41 Btuh/Watt x 1.00 = 2,957 rocess Chedule 1.0 x 1,733 x. 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 1 733 x 10.00 x 0.50 /601 x 34 = 5 225 Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 38,013 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 1 733 X 300 Btuh/OCC. / 100 sgft/occ. = 5199 Receptacle 1.00 x x nnn.Q Watts/sqft x Btuh[Watt = rocess 1.00 x 1,733 x 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = 0 Infiltration: x x L �,z331 x � x n 50 / 6] x o_on2sz = ��,g0g� chedule Air Latent Area Gelling Height ACH pyy ROOM COOLING PEAK LOADS I project Title Date j Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Sep 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 107 '� Indoor Dry Bulb Temperature 78cl� Outdoor Wet Bulb Temperature 74 `k Conduction -30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 19 Wall .19.2x6.16 ouble Non Metal Tinted ouble Non Metal Tinted -19 Wall .19.2x6.16 ouble Non Metal Tinted ouble Non Metal Tinted Double Non Metal Tinted Area 690.0 320.0 175.0 17.5 17.5 232.5 17.5 17.5 17.5 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (`) denote conduction through an interior surface to another room. Solar Gain indow indow indow indow idow .rfndow Window Window Window Window U -Value 0.0360 0.0740 0.0740 0.5800 0.5800 0.0740 0.5800 0.5800 0.5800 X X X X X X X X X DETD t = = = = = = = = = 51.6 27.5 29.8 20.4 20.4 41.6 20.4 20.4 20.4 Page Total Orientation Area X X x X X x X X X X SGF X X X x X X x X X x Sc Weighting X X X X X X x X X X Factor = = = = = = = = = (E) 17.5 27 0.590 2.331 (E) 17.5 27 0.590 2.331 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (S) 17.5 112 0.590 1.055 (W) 16.0 76 0.590 0.495 (W) 48.0 76 0.590 0.495 16.0 76 0.590 0.495 Page Total Btu/hr 1,283 652 385 207 207 716 207 207 207 4 072 Btu/hr 650 650 1,220 1,220 1.220 1,220 1,220 354 1 062 354 9 171 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 690 X 1.078 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c X 690 x 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 2,070 Receptacle 1.0 x 690 x 0.500 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 1,177 rocess 1.0 X 690 X 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration:1.00 X 1.064 X 690 x 10.00 X 0.50 /601 X 34 = 2 081 Ledule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,555 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 690 x 3001 Btuh/occ. / 100 sgft/occ. = 2 070 Receptacle 1.0o x x nnn Watts/sgft x Btuh/Watt Process 1.00 x 690 X 0.000 Watts/sgft x1 3.4131 BtuhlWatt = o Infiltration: xx x x () 50 / 60] x ®_ chedule Alr Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Project Title Date �i Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Sep 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 107 `k Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 74 cll� Conduction Area 17.5 X 17.5 X 130.0 X 16.0 X 48.0 X 16.0 X 690.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.5800 0.5800 DETD ' X X X X X X X X X 20.4 = = = = = = = = = 20.4 50.0 20.4 20.4 20.4 23.6 Page Total Weighting Orientation Area SGF SC Factor x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = Page Total Btulhr 207 207 481 189 568 189 603 2 446 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 11.0c X 690 X 1.078 Watts/sqft X 3.41 Btuh/Watt x 1.000 = 2,539 ccu ants 1.0c X 690 x 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 2,070 Receptacle 1.0c X 690 x 0.500 Watts/sgft x 3.41 Btuh[Watt x 1.00 = 1,177 rocess Ledule 1.0 X 690 X 0.000 Watts/sqft X 3.41 BtuhlWatt X 1.00 = 0 Infiltration: 1.00 x 1.064 x 690 x 10.00 x 0.50 /601 x 34 = 2 08 Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,555 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 690 1 x 300 Btuh/occ. / 100 sgft/occ. = 2 070 Receptacle 1.00 x 6901 x 0 Ono Watts/sqft x Btuh/Watt = rocess 1.00 x E x 0.000 Watts/sqft xJ 3.413 Btuh/Watt = 0 Infiltration: Area x x � x 1p nn x ACH / 6 ] x o oon03 = Ledule Air Latent Ceiling Height CH pyy ROOM COOLING COIL LOADS ritie Date Calle Estado, LLC I 6/13/2007 I Room Name Suite 101 Time of Peak Jul 3 pm Floor Area 820 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74`k Outdoor Wet Bulb Temperature 78 OF Conduction -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 19 Wall W.19.2x6.16 0.590 0.811 (N) 48.0 Area 178.0 140.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain ndow U -Value 1 0.07401 DETD 1 X X X X X X X X X 37.8 = = = = = = = = = 27.9 27.9 39.2 40.1 40.2 58.2 (N) 24.0 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X x X X X Factor = = = = = = = = (N) 24.0 4 0.590 0.811 (N) 48.0 4 0.590 0.811 (N) 24.0 4 0.590 0.811 (N) 36.0 4 0.590 0.807 (NE) 36.0 4 0.590 1.217 (E) 36.0 4 0.590 1.532 (S) 20.0 42 0.590 0.793 S 24.0 42 0.590 0.793 Page Total Btu/hr 498 2,266 1,748 185- 487 1,030 65 6 277 Btu/hr 471 942 471 703 1.060 1.334 393 471 5,845 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c X 820 X 0.794 Watts/sgft X 3.41 Btuh/Watt X 0.999 = 2,219 ccu ants 1.0 X 820 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 2,460 Receptacle 1.0 X 820 X 1.000 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 2,799 rocess 1.0 x 820 x 0.000 Watts/sqft X 3.41 BtuhlWatt X 1.00 = 0 Infiltration:Ledule 1.00 x 1.osa x 820 x 10.00 x 0.50 /601 x 38 = z 7s3 Air Sensible Area Coiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,363 Sched. Btulhr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 820 X 30ol Btuh/OCC./ sgft/occ. = 2 460 Receptacle 1.on x x Watts/sgft x 100 Btuh/Watt = Process 1.00 X 820 X 0.000 Watts/sgft x 1 3.413 Btuh/Watt = o Infiltration: x x � x 10.00 x �_ H 5Q / 6] x chedule Air Latent Area Ceiling Height ACpW r EnerpyPro By EnergvSoft User Number: User Page: 89 of 102 1 ROOM COOLING COIL LOADS ,Ject Title Date Calle Estado, LLC 6/13/2007 r _ Room Name Suite 102 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 74c� Outdoor Wet Bulb Temperature 78 Conduction k-19 Wall (W.19.2x6.16) I Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value DETD 1 37.8 = 27.9 = 40.2 = 27.9 Page Total Orientation Area X X X X X X X x X X SGF X X X X X X X X X X Sc Weighting X X X X X X X X X. X Factor = = = = = (N) 24.0 41 0.590 0.811 (N, 48.0 41 0.590 0.811 N 24.0 41 0.590 0.811 (S) 24.0 42 0.590 0.793 (S) 25.0 42 0.590 0.793 Page Total Btu/hr 193 1,942 345 405 2 885 Btulhr 471 942 471 472 491 2 847 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 433 X 1.289 Watts/sqft X 3.41 Btuh/Watt X 0.999 = 1,902 ccu ants 1.0c x 433 x 300 Btuhlocc. / 10 sgft/occ. x 1.00 = 1,29 Receptacle 1.0( X 433 X 1.500 Watts/sgft x 3.41 BtuhlWatt X 1.00 = 2,217 Process 1.0 X 433 X 0.000 Watts/sqft X 3.41 BtuhlWatt X 1.00 = 0 Infiltration: 1.00 X 1.064 X 433 X 10.00 X 0.50 l6] X 38 = 1459 Lhedule Air Sensible Area Ceiling Height ACH Z�,T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,608 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 433 X mol Btuhlocc. / 100 sqftlocc. = 1 299 Receptacle 1.00 x x 0.00 Watts/sqft X Btuh/Watt = rocess 1.00 X 433 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 Infiltration: xx x �( x D �o / 6] x ®_ cheduie Air Latent Area Ceiling Height ACH pW i EnergvPro By EnemySoft User Number: User Page: 90 of 102 1 ROOM COOLING COIL LOADS )lect Title Date Calle Estado, LLC 1 6/13/2007 Room Name Suite 103 Time of Peak Jul 3 pm Floor Area 484 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 74`: Outdoor Wet Bulb Temperature 78 91 Conduction 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.24.16 Solid Wood Door Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.58001 DETD 1 X X X X X X X X X 38.4 = = = = = = = - = 28.3 41.1 28.3 59.1 55.2 = = = = = = = = = = (N) 24.0 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) _ 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 25.0 42 0.590 0.868 Page Total Btu/hr 381 1,971 550 411 1,054 1.92 6 288 Btu/hr 509 1,018 509 516 538 3 089 Sched. Weighting gtulhr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 484 X 1.285 Watts/sgft X 3.41 BtuhlWatt X 1.000 = 2,123 ccu ants 1.0 X 484 X 300 Btuh/occ. / 10 sgftlocc. X 1.00 = 1.452 Receptacle 1.0 X 484 X 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 826 rocess 1.0 X 484 X 1.500 Watts/sqft X 3.41 BtuhlWatt X 1.00 = 2,478 Infiltration: 1.00 X Sensible X 484 X 10.00 X 0.50 /601 X 38 = 1 63 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,886 Sched. Btulhr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 484 X 3001 Btuh/OCC. / 1 100 sgft/occ. = 1 452 Receptacle 1.00 x x Watts/sgft x 1 3 4131 Btuh/Watt = Process 1.00 X 484 X 0.000 Watts/sgft X 1 3.413 Btuh/Watt = 0 Infiltration: 1 OD x a 77 x x =� x / 60] x chedule Air Latent Area Ceiling Height ACH pW I EnerayPro By EnergySoft User Number: User Page: 91 of 102 1 ROOM COOLING COIL LOADS Project Title Date Calle Estado, LLC 6/13/2007 KOOM INFORMATION DESIGN CONDITIONS Room Name Suite 104 Time of Peak Jul 3 pm Floor Area 484 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 789: Outdoor Wet Bulb Temperature 78 9F Conduction -19 Wall (W.19.2x6.16) 1 Area X X X X X X X X X U -Value X X X X X X X X X 134.0 0.0740 120.0 0.5800 265.0 0.0740 181.0 0.0740 25.0 0.5800 24.0 1. Design Equivaient Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area (N) 24.0 N 48.0 (M 24.0 (S) 25.0 (S) 24.0 SGF SC x 0.590 X 0.590 X 0.590 x 0.590 X 0.590 x X X X X DETD 1 34.4 = 24.5 = 36.8 = 37.1 = 24.5 = Page Total Weighting Factor X 0.876 = X 0.876 = X 0.876 = X 0.868 = X 0.868 = X X = X X X = Page Total Btu/hr 341 1,704 722 497 355 3 619 Btu/hr 509 1,018 509 538 516 3 089 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 X 484 X 1.285 Watts/sqft Xg3.41, Btuh/Watt X 1.000 = 2,123 ccu ants 1.0 X 484 X 300 Btuh/OCC. I sgftlocc. X 1.00 = 1,45 Receptacle 1.0 X 484 X 0.500 Watts/sgft XBtuh/Watt x 1.00 = 826 rocess Ledule 1.0 X 484 X 0.000 Wafts/sqft X Btuh/Watt X 1.00 = 0 Infiltration: 1.00 X 1.064 x 484 x 10.00 x 0.50 1601 x = 1 459 Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,567 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 484 X 3001 Btuh/OCC. / 100 sgft/occ. = 1452 Receptacle 100 x x() -000i Watts/sqft x Btuhmatt - rocess 1.00 x 484 x 0.000 Watts/sqft x 3.413 Btuh/Watt - 0 Infiltration: x77 x �- 4R4 x x 160] x E = 505 chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Title Date ) Calle Estado, LLC 1 6/13/2007 1 Room Name Suite 105 Time of Peak Jul 3 pm Floor Area 433 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 78c� Outdoor Wet Bulb Temperature 78 `k Conduction h-19 Wall (W.19.2x6.16) 1 ouble Non Metal Tinted Area 69.0 144.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window )indow U -Value DETD 1 34.41 = 24.5 = 37.1 = Page Total Orientation Area X X X X X X X x x X SGF X X X X X x X X XX X SC Weighting X X X X x x X X X Factor = = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Btulhr 176 2,045 321 2 541 Btu/hr 509 1,018 509 516 516 3 067 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c x 433 x 1.289 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 1,904 ccu ants 1.0c X 433 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 1,299 Receptacle 1.0 x 433 x 0.500 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 739 rocess 1.0c X 433 X 0.000 Watts/sgft X 3.41 Btuh[Watt X 1.00 = 0 Infiltration: 1.00 x 1.064 x 433 x 10.00 x 0.50 /601 x 34 = 1 306 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,857 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 433 X 300 Btuh/occ. / 100 sgft/occ. = 1 299 Receptacle 1.0o x x o onn Watts/sgft x Btuh/Watt Process 1.00 X 433 X 0.000 Watts/sgft X 1 3.4131 Btuh/Watt = 0 Infiltration: x x 1 433 X x/ 60] x= Cg� chedule Air Latent Area Ceiling Height ACH Qw ROOM COOLING COIL LOADS P__roject Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 106 Time of Peak Jul 3 pm Floor Area 578 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 78`I: Outdoor Wet Bulb Temperature 78 OF Conduction h-19 Wali (W.19.2x6.16) ouble Non Metal Tinted Area 290 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (•) denote conduction through an interior surface to another room. Solar Gain Window Window Window r U -Value 1 0.07401 X X X X X X X X X DETD 1 = = = = = = = = = 34.4 24.5 36.8 55.1 Factor = = = = = = = = U 24.0 41 Page Total Orientation Area X x X X X x X X x x SGF X X X X X x x x xx x Sc Weighting X X X X X x x x x Factor = = = = = = = = U 24.0 41 0.590 0.876 N 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 Page Total Btu/hr 290 1,363 82 1,183 2 918 Btu/hr 509 1,018 509 2,035 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btulhr i hts 1.01 X 578 X 1.287 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c X 578 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 1,734 Receptacle 1.0 X 578 X 0.500 Wafts/sgft x 3.41 Btuh/Watt X 1.00 = 986 rocess 1.0 x 578 X 0.000 Wafts/sgft X 3.41 Btuh[Watt X 1.00 = 0 Infiltration: 1.00 x 1.064 x 578 x 10.00 x 0.50 16] x &J = 1743 chedule Air Sensible Area Ceiling Height ACH DT ' Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,955 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 578 X 3ool Btuh/occ. / 100 sgft/OCc. = 1 734 Receptacle 1.00 x x n naQ Watts/sgft x 1 3 4131 Btuh/Watt = rocess 1.0o x s78 x o.000 Wafts/sgft x 1 3.413 Btuh/Watt = o Infiltration: x x x ,eight x �� / 6] x � _ chedule Air Latent Area Ceiling Height ACH pyy IROOM COOLING COIL LOADS Project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 107 Time of Peak Jul 3 pm Floor Area 405 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 78 cl� Conduction -19 Wall .19.24.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted 19 Wall .19.24.16 -19 Wall .19.2x6.16 Area X X X X X X X X X U -Value 94.0 0.0740 24.0 0.5800 48.0 0.5800 24.0 0.5800 210.0 0.0740 190.0 0.0740 = X = X = 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Page Total Orientation DETD t X 36.8 = X 24.5 = X 24.5 = X 24.5 = X 37.1 = X 55.1 = X = X = X = Page Total Orientation Area 24.0 X 48.0 X 24.0 X X X X X X X X SGF X X X X X X X X X X SC Weighting x X X X X X X X X X Factor = = = = = = = = (E) 4 0.590 1.116 (E) 4 0.590 1.116 (E) 4 0.590 1.116 Page Total Btu/hr 256 341 682 341 576 775 2 971 Btu/hr 648 1,296 648 2 593 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c X 405 X 1.378 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 1,904 ccu ants 1.0c X 405 X 300 Btuh/occ. / 10 sgft/occ. X 1.00 = 1,215 Receptacle 1.0c X 405 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 691 rocess 1.0 X 405 X 0.000 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration: 1.00 X 1.064 X 405 X 10.00 X 0.50 / 60] X 34 = 1.2211 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,595 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 405 X 30ol Btuh/OCC. / 100 sqft/occ. = 1 215 Receptacle 1.00 x x 0 Watts/sgft x BtuhlWatt = rooess 1.00 X 405 X 0.000 Watts/sgft X 1 3.4131 Btuh/Watt = 0 Infiltration: x x [� aos� x x / 6] x ®= 4?3_ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS ct Title Date i Calle Estado, LLC I 6/13/2007 Room Name Suite 201 Time of Peak Jul 3 pm Floor Area 619 Outdoor Dry Bulb Temperature 112 9 Indoor Dry Bulb Temperature 780F Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof R.30.2A2.16 -19 Wall .19.2x6.16 Double Non Metal Tinted 19 Wall .19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Double Non Metal Tinted 19 Wall .19.2x6.16 Area 619.0 139.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window ,`indow vJindow U -Value 1 0.03601 DETD 1 X X X X X X X X X 70.3 = = = = = = = = = 34.4 24.5 35.8 24.5 36.8 24.5 37.1 24.0 Page Total Orientation Area X X X X X X X X XX X SGF X X X X X X X X X SC Weighting X X X x X X X X X X Factor = = = = = = (N) 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (NE) 36.0 4 0.590 1.274 Q 36.0 4 0.590 1.594 (S) 24.0 42 0.590 0.868 Page Total Btu/hr 1,566 354 1,704 170 511 338 511 785 5 939 Btu/hr 509 1,018 509 1,110 1,388 516 5 049 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c x 619 x 1.052 Watts/sqft x 3.41 Btuh/Watt X 1.000 = 2,222 ccu ants 1.0c X 619 X 300 Btuh/occ. / 10 sgft/occ. x 1.00 = 1,857 Receptacle 1.0 X 619 X 0.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 1,056 rocess 1.0c X 619 X 0.000 Watts/sgft X 3.41 Btuh[Watt X 1.00 = 0 Infiltration:1.00 X 1.064 X 619 X 10.00 X 0.50 16] X 34 = 1 866 Ledule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,990 Sched. Btulhr Latent Gain Frac. Area Heat Gain ccu ants 1 1.00 x 619 x 3001 Btuh/occ. / 100 sgft/occ. = 1 857 Receptacle L 1.00 x x 0 0001 Watts/sqft x Btuh/Watt = Process 1.00 X 619 x 0.000 Watts/sgft x 1 3.4131 Btuhfwatt = 0 Infiltration: x x �g x x / 60] x chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Title Date 't Calle Estado, LLC 1 6/13/2007 1 Room Name Suite 202 Time of Peak Jul 3 pm Floor Area 728 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 78c� Outdoor Wet Bulb Temperature 78 °k Conduction 30 Roof R.30.2x12.16 -19 Watl .19.2x6.16 Double Non Metal Tinted -19 Wall .19.24.16 -19 Wall .19.2x6.16 Double Non Metal Tinted -19 Floor Assembly Area 1 728.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value Orientation Area X X X X X X X X X X SGF (N) 24.0 4 (N) 48.0 4 (N) 24.0 4 (S) 30.0 42 (S) 24.0 42 0. SC DETD 1 x x X X X X X x x 70.3 = = = = = = = = = 34.4 24.5 36.8 37.1 24.5 28.6 X 0.590 X 0.590 X 0.590 X 0.590 X 0.590 X X X X X Page Total Weighting Factor X 0.876 = X 0.876 = X 0.876 = X 0.868 = X 0.868 = X = X X = X X Page Total Btu/hr 1,842 163 1,704 545 414 426 297 5 391 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Btulhr Internal Gain Frac. Area Heat Gain Factor. fights 1.0c x 728 x 1.022 Wattslsgft x 3.4V Btuh/Watt x 1.000 = 2,539 ccu ants 1.0c X 728 x 300 Btuh/occ. / 10 sgft/OCc. X 1.00 = 2,184 Receptacle 1.0 X 728 X 0.500 Wafts/sqft x 3.41 Btuh[Watt X 1.00 = 1,242 rocess 1.0 x 728 x 0.000 Watts/sqft x 3.41 BtuhlWatt x 1.00 = 0 Infiltration: 1.00 X 1.064 X 728 X 10.00 X 0.50 /601 X = 2 195 chedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,748 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 728 X 300 Btuh/occ. / 100 sgft/occ. = 2184 Receptacle 1.00 x x Wattslsgft x Btuh/Watt = Process 1.00 X 728 X 0.000 Watts/sgft x 1 3.413 Btuh/Watt = 0 Infiltration: x 4 77 x E x x[ ()5o]/ 6] x o Dn2sz = chedule Alr Latent Area Ceiling Height ACH pw -771 ROOM COOLING COIL LOADS . project Title Date Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 203 Time of Peak Jul 3 pm Floor Area 781 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 78`k Outdoor Wet Bulb Temperature 78 9F Conduction 30 Roof R.30.2x12.16 -19 Wall .19.2x6.16 Double Non Metal Tinted 19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Solid Wood Door 19 Floor Assembly Area 781.0 X 134.0 X 150.0 X 176.0 X 366.0 X 24.0 X 266.0 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (•) denote conduction through an interior surface to another room. Solar Gain Window Window indow .Window ndow U -Value 0.0360 0.0740 X X X X X X X X X DETD 1 = = = = = = = = = 70.3 34.4 24.5 37.1 55.1 52.9 28.6 24.0 41 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = (N) 24.0 41 0.590 0.876 (N) 48.0 41 0.590 0.876 (N) 24.0 41 0.590 0.876 (S) 24.0 42 0.590 0.868 (S) 30.0 42 0.590 0.868 Page Total Btu/hr 1,976 341 2,130 483 1,493 1,842 282 8 548 Btu/hr 509 U18 509 516 645 3196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 781 x 1.273 Watts/sgft x 3.41 Btuh/Watt x 1.000 = 3,392 ccu ants 1.0 x 781 x 300 Btuh/occ. / 10 sqft/occ. x 1.00 = 2,343 Receptacle 1.0c X 781 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 1,333 Process r1.0 x 781 X 0.000 Watts/sgft X 3.41 Btuh[Watt X 1.00 = 0 Infiltration: I 1.00 x 1.064 x 781 x 10.00 x 6] x � = 2 355 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,167 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 781 x 300 Btuh/OCC. / 100 sgft/occ. = 2 343 Receptacle 1.nn x x 0 QM Watts/sgft x 3.4131 Btuh/Watt = rocess 1.00 x 781 x 0.000 Wafts/sqft x 3.4131 Btuh/Watt = 0 Infiltration: x x F x x � / 6] x n l = A15 chedule Air Latent Area Ceiling Height ACH pwyy ROOM COOLING COIL LOADS I.eroject Title ROOM INFOI Room Name Calle Estado, LLC oor Area door Dry Bulb Temperature Conduction 30 Roof(R.30.202.16) -19 Wall W.19.2x6.16 Double Non Metal Tinted -19 Wall .19.2x6.16 Solid Wood Door -19 Wall .19.24.16 19 Floor Assembly Suite 204 860 78c� Time of Peak Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Area X X X X X X X X X U -Value X X X X X X X X X 860.0 0.0360 134.0 0.0740 150.0 0.5800 366.0 0.0740 24.0 1.4500 246.0 0.0740 266.0 0.0370 24.0 4 0.590 0.876 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Date 6/13/2007 DETD t 70.3 = 34.4 = 24.5 = 36.8 = 30.8 = 37.1 = 28.6 = Page Total Orientation Area X X X X X X X X X X SGF X X x X x X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = (N) 24.0 4 0.590 0.876 N 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (S) 30.0 42 0.590 0.868 (S) 24.0 42 0.590 0.868 Page Total Jul 3 pm 112 78 '� Btu/hr 2,176 341 2J30 997 1,071 675 282 E777767721 Btu/hr 509 1,018 509 645 516 3 196 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0c x 860 x 1.264 Watts/sgft x 3.41 BtuhM►att x 1.000 = 3,709 ccu ants 1.0 x 860 x 300 Btuh/occ. I 10C sgft/occ. x 1.00 = 2,58 Receptacle 1.0 X 860 X 0.500 Wafts/sgft x 3.41 Btuh/Watt X 1.00 = 1,468 rocess 1.0 x 860 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration:Ledute 1.00 x 1.064 x 860 X 10.00 x 0.50 /601 x 34 = 2 593 Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,219 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 860 X 3001 Btuhlocc. / F7771R sqft/occ. = 2 580 Receptacle 1.00 x x 0,0001 Wattslsgft x BtuhMatt = rocess 1.00 x 860 x 0.000 Watts/sgft X 3.413 Btuh/Watt = o Infiltration: x x sso x x 6] x �p�p�2� _ chedule Atr Latent Area Ceiling Height ACH pyy Y ROOM COOLING COIL LOADS P_ roject Title Date I Calle Estado, LLC 1 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name suite 205 Time of Peak Jul 3 pm Floor Area 1,733 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 78c� Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof R.30.2x12.16 -19 Wall .19.24.16 Double Non Metal Tinted -19 Wall .19.2x6.16 ouble Non Metal Tinted -19 Wall W.19.2x6.16 ouble Non Metal Tinted -19 Wall .19.2x6.16 -19 Floor Assembly Area 1 1.733.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.03601 1 0.03701 DETD t 70.3 = 34.4 = 24.5 = 36.8 = 24.5 = 37.1 = 24.5 = 55.1 = 28.6 = Page Total Orientation Area X X X X X x X X X x SGF X X X X X X X X X X SC Weighting X X X X X X x X X x Factor = = = = = = = = = = (N) 24.0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 (N) 24:0 4 0.590 0.876 (N) 48.0 4 0.590 0.876 (N) 24.0 4 0.590 0.876 Q 30.0 4 0.590 1.270 (S) 48.0 42 0.590 0.868 (S) 25.0 42 0.590 0.868 I Page Total Btulhr 4,385 479 3,408 259 426 843 355 2,080 279 12 513 Btu/hr 509 1,018 509 509 1,018 509 922 1,032 538 6,562 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btulhr fights 1.01 X 1,733 X 0.939 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 5,556 ccu ants 1.0c X 1,733 X 300 Btuhlocc. / 10 sgftlocc. X 1.00 = 5199 Receptacle 1.0 X 1,733 X 0.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 2,957 rocess 1.0 x 1,733 X 0.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 X 1.064 X 1 733 X 10.00 X 0.50 1601 X 34 = 5 225 Lhedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 38,013 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1 1.00 X 1 1,7331 X 3001 Btuh/OCC. / 100 sgft/occ. = 5199 ece tacle1.00 x x Watts/sgft x Btuh[Watt = rocess 1.00 X 1,733 X 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Infiltration: x a 77 x 1 733 x x/ 60] x chedule Air Latent Area Ceiling Height ACH pyo r ROOM COOLING COIL LOADS P_ roject Title Date .L Calle Estado, LLC 6/13/2007 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 206 Time of Peak Aug 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 78C' Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof(R.30.2x12.16) -19 Wall .19.2x6.16 -19 Wall .19.2x6.16 Double Non Metal Tinted Double Non Metal Tinted -19 Wall W.192x6.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Metal Tinted Area 690.0 320.0 175.0 17.5 17.5 232.5 17.5 17.5 17.5 S. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 0.0740 0.5800 0.5800 0.0740 0.5800 0.5800 0.5800 X X X X X X X X X DETD 1 = = = = = 65.2 33.5 35.9 24.5 24.5 = = = = = = = = = = (E) 24.5 24.5 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = = = = (E) 17.5 36 0.590 2.078 (E) 17.5 36 0.590 2.078 (S) 17.5 70 0.590 1.112 (S) 17.5 70 0.590 1.112 (S)_ 17.5 70 0.590 1.112 (S) 17.5 70 0.590 1.112 (S) 17.5 70 0.590 1.112 M. 16.0 5 0.590 0.730 48.0 51 0.590 0.730 16.0 5 0.590 0.730 Page Total Btu/hr 1,619 792 465 248 248 717 248 248 248 4 635 Btu/hr 772 772 804 804 804 804 804 351 1.054 351 7 319 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 690 x 1.078 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 2,539 ccu ants 1.0c x 690 X 300 Btuhlocc. / 10 sgftlocc. x 1.00 = 2,07 Receptacle 1.0c X 690 X 0.500 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 1,177 rocess 1.0 x 690 x 0.000 Watts/sgft X 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 690 x 10.00 x 0.50 /601 x 1 34 = 2 081 chedule Air Sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,915 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.o0 X 690 x 3ool Btuhlocc. / 100 sgft/occ. = 2 070 ece tacle 1.0o x x a on Watts/sgft x q 4 1 q I Btuh/Watt = rocess 1.00 x 690 X 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = o Infiltration: s xx x 10 DO x H 5� / 6] x � _ chedule Air Latent Area Ceiling Height ACpVU h' ROOM COOLING COIL LOADS roject Title Date Calle Estado, LLC 6/13/2007 Room Name Suite 206 Time of Peak Aug 3 pm Floor Area 690 Outdoor Dry Bulb Temperature 112 `F Indoor Dry Bulb Temperature 78c� Outdoor Wet Bulb Temperature 78 c ' Conduction Metal Tinted 19 Floor Area 17 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.58001 DETD 1 X X X X X X X X X 24.5 = = = = = = = = = 24.5 55.0 24.5 24.5 24.5 28.6 Page Total Weighting Orientation Area SGF SC Factor x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = X x x = Page Total Btu/hr 248 248 529 227 682 227 731 2 893 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 690 X 1.078 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 2,539 ccu ants 1.0c x 690 x 300 Btuh/occ. / 10 sqft/occ. x 1.00 = 2,070 Receptacle 1.0c x 690 x 0.500 Watts/sgft x 3.41 BtuhlWatt x 1.00 = 1,177 rocess 1.0 x 690 X 0.000 Watts/sqft x 3.41 BtuhlWatt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 690 x 10.00 x 0.50 1601 x 34 = 2 081 chedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,915 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 690 x 3001 Btuh/occ./ sgft/occ. = 2 070 Receptacle 1.001 x xJ Watts/sgft x Btuh/Watt = rocess 1.00 x 690 x 0.000 E100 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: xC x x � 1 x � / 6] x �&W _ chedule Air Latent Area Ceiling Height ACH QW John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning v. Beaumont Calimesa Canyon Lake Coachella Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage Rubidoux CSD San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date I — Z 3— 0O La Quinta Building Department RE ffiCISION 00e The Riverside County Fire Department is granting the fire clearance for the following location 7 � y 115 % I l! e &5-W, -4 203 Please call if you should have questions. 760-863-8886. Thank You spectfully, Jason Stubble Fire Systems Inspector