Loading...
13-1655 (RC)T -&f 4 4 P.O. BOX 1504 "0 VOICE (760) 777-7012 78-495 CALLE TAMPICO �r FAX (760) 777-7011 ,` LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT S INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/06/14 Application Number: 13-00001655 Owner: Property Address: 78115 CALLE ESTADO STE 205 THE RILINGTON GROUP APN: 770-152-010- - - 78-080 CALLE ESTADO Application description: REMODEL - COMMERCIAL LA QUINTI , CA Property Zoning: VILLAGE COMMERCIAL LA QUINTA, CA 95523 -- Application valuation: 45000 Contractor: Applicant: Architect or Engineer: VANDALAY GROUP INC, THE o' 1_3 0 -� A ilr ! 78115 CALLE ESTADO #205 i - LA QUINTA, CA 92253 (619) 889-0909 Lic. No.: 942744 ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Busin s and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: 942744 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is / —issued. Dat Contractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EXEMPT Policy Number EXEMPT following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I sh come subject t e workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 2 3700 of the Labor C de, I s all fofih ith cpmqly with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by �{ any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: rt Date: C ` Applicant. (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.l. (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to b rl(311 g construction, and hereby authorize representatives of this county to enter upon the above•mentione pro arty or inspection purposes. Date I� Signature (Applicant or Agent): Application Number . . . . . 13-00001655 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 23.83 Plan Check Fee [� .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/05/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 -----------------------------------------------------------------------_----- 23.83 Permit . . . MECHANICAL 2013 Additional desc . Permit Fee . . . . 11.92 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/05/14 Qty Unit Charge Per Extension 1.00 11.9200 EA MECH APPL REP/ALT ---------------------------------------------------------------------------- 11.92 Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . 35.76 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date . 8/05/14 Qty Unit Charge Per Extension 1.00. 11.9200 EA PLBG FIXTURE/TRAP 11.92 1.00 11.9200 EA PLBG WATER HEATER/VENT 11.92 1.00 11.9200 EA PLBG WATER INST/ALT/REP ---------------------------------------------------------------------------- 111.92 Permit . . . REMODEL 2013 Additional desc . . Permit Fee . . . 112.97 Plan .Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 8/05/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62 3.00 21.4500 EA MISC REMODEL, ADDL 500 SF 64.35 ---------------------------------------------------------------------------- Special Notes and Comments TENANT IMPROVEMENT 1680 SQ. FT. OFFICE SPACE February 6, 2014 10:20:38 AM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 LQPERMIT Application Number . . . . . 13-00001655 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 184.47 4 14 PLAN CHECK, MECHANICAL 4.77 PLAN CHECK, PLUMBING 30.99 STRONG MOTION (SMI) - COM 9.45 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 184.48 ---------- .00 -------------------- .00 184.48 Plan Check Total .00 .00 .00 .00 Other Fee Total 255.51 .00 .00 255.51 Grand Total 439.99 .00 .00 439.99 LQPERMIT Bin # C r4 city of La. Quinta % Building 8L Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit' Project Address: % D I (� T�YW , - -Zb Owner's Name:A. P. Number: 7 70 - l S Z— 617 Address: -7 C4U,9 W-- Id v Legal Description: Contractor: CKk CP'�VjTelephone: City, ST, Zip: l�l%� �t (iZ S 3 Cq — :rf ii :•.4y Address: 7 d CA"If !%.b b Project Description: 1-FA/41)T I�A --00City, ST, Zip: � 7i7-� ✓O C 6Y-46 C) .GW PIA137, /4 6 Telephone: m b :City State Lic. # : �t9 �� Lie. 9...J• . (7. 9%/�L �� 6 .�. Arch., Engr., Designer. 6f �U14M S I �lI/�/ jr✓Vb Address: City., ST, Zip: Z—'t7 Telephone: p �� � 4:;:1':i:'F,.jy,:.:,`vi`:flJnii�i :iii: `:iiv riiiiiin <>><<:::::.::,...::•<;:::;,;.::::.;;.:.:.::..;';::. .p ::.:<.:>;;:<;.;.::r;-:;;;:.>:..:<:<;:i:<.ii::.::! Construction Type: p Occupancy: :>x::i.:z:>::- Project type (circle one): New Add'n Alter Repair Demo .................................................... -#:�j�`��i'� State Lic. d{: G 3-3 Name of Contact Person: Sq. Ft.: 1,66C) # Stories: S4,4j #Units: Telephone #,of Contact Person: 76/ -5-76-q R 44 Estimated Value of Project: (� APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, readfor corrections / / Plan Check Deposit Truss Cales. Title 24 Calcs. W� Called Contact Per so ,2 I�fL Plans picked up u71/.�p ' % Plan Check Balance. Construction Flood plain plan Plans resubmitted^ tad Review, ready for corrections Issue ._ ' Mechanical Grading plan Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Rte - CW � 0 -. Ctw PR40UDLY SE14 THE 1jNFNCORP0R4AREAS DF FVVERSIVEQm 6"p THE CME4 SA,r4NING �;E^LJMONT EAL_! MESA CANYON LAKE C ORCHELLA EIESERT HOT Sig LASrVALE i DIAN WELLS 4nlo JJRUPA VALLEY LIKE ELSINORE L,� G?UINTA t4EN I F'EE N,DRENO VALLEY NORCO PALM DESERT PFRRIS RANCHO MIRAGE RUBIDOUx CS6 SAN JACINTO "rEMECULA WILDOMAR EIGARD OF SUpEWJSORS: KEVIN JEFFR.IES DISTRICT t JoyN TA DIST OCT 2 JeFIF STONE DISTRICT 3 JOHN BENOI DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE. DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montahas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org January 30, 2014 RE: TENANT IMPROVEMENT PLAN CHECK -Non Structural LAQ-I4-TI-002 The Vandalay Group 78=115 Calle Estado 4205 La Quinta, CA You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. It is prohibited to use/process or store any materials in this occupancy that would. classify it as an "H" occupancy per Sec. 307 of the 2013 CBC. THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Install door hardware and exit signs as per Chapter 10 of the CBC. A minimum 2A1 OBC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background. An approved audible interior notification alarm device shall be provided in approved location. A C-10 licensed contractor must submit plana—designed in accordance with NFPA 72 to the Fire Department for review and approval prior to installation Approved suite addresses shall be placed in such a position to be plainly visible and legible from the street. Said numbers shall contrast with their background. Provide key(s) to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification. Key(s) shall be provided at time of final inspection. As it may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire sprinkler system plans for the tenant improvement area may be required to be submitted to the Fire Department for review. . I i i I Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A. re -inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at: least 72 hours in advance and may be arranged by calling (760) 863 8886. y All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863 8886. i I Sincerely, • i i By: J n Stubble Fir Safety Specialist . f a k c. BUILDING ENERGY ANALYSIS REPORT PROJECT: Rilington Tenant Improvement 78-115 Calle Estado, Suite 205 La Quinta, CA 92253 Project Designer: /; C, O �� 0'o c F� G�y 2�< �40 '1' 0"" 1p McGEE SHARON ARCHITECTS.` 1530 West Lewis Street 0,01 San San Diego, CA 92103 p�F,yT i Of ICS' C�Ip Report Prepared by: Dennis Hurvitz, P.E. Desert Engineers 75401 Painted Desert Drive Indian Wells, Ca. 92210 (760) 568-9600 Job Number: Date: 12/21/2013 The EnergyPro computer program has been used to perform the calculations summarized in authorized by the California Energy Commission for use with both the Residential and Nor This program developed by EnergySoft, LLC — www. Cl-r� OF LA QUINTA LUIL_IDINC & SAFETY DEPT. APPROVED is complia�ice re�ort�Tlii§ pro ram ha�s�appro, sidential 2008 Building Energ fficie cy Stan ierovsoft.dird I (/1— BY— is Z I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 12 CtTy OF LA QUINTA BUILDING & SAFETY SDEPT. d - iia I A I -S� FOR CONSTRUCTION DATE _----- BY _o EnergyPro 5.1 by EnergySoft Job Number. ID: User Number. 5769 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 C Project Name Date Rilington Tenant Improvement 1 12/21/2013 Project Address Climate Zone Total Cond. Floor Area Addition Floor Area 78-115 Calle Estado, Suite 205 La Quinta CA Climate Zone 15 1,648 0 GENERAL INFORMATION Building Type: ® Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room ❑ Relocatable -indicate ❑ specific climate zone ❑ all climates Phase of Construction: ❑ New Construction ❑ Addition ® Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author / Name Dennis Hurvitz, P.E. Signature Company Desert Engineers Date 12/21/1013 Address 75401 Painted Desert Drive Phone (760) 568-9600 City/State/Zip Indian Wells, Ca. 92210 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110, 116 through 118, and 140 through 149 of Title 24, Part 6. Please check one: ENV. LTG. MECH. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to ❑ ❑ ❑ sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section ❑ ❑ ❑ 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document ❑ ❑ ❑ because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not In The Scope Of This Document Date Address License '#, City/State/Zip P Principal Mechanical Designer Name Dennis Hurvitz, P.E. Signature Company Desert Engineers Date Z D cc 2v 3 Address 75401 Painted Desert Drive License # M Z 10 z3 Z City/State/Zip Indian Wells, Ca 92210 Phone (760) 568-9600 Principal Lighting Designer Name Signature r-------�'� ni 11N Company Company ' Y Date Lighting Compliance Not /n The Scope Of This Submittal r �. ct =-TY DEPT. Address City/State/Zip '11 L-- -. r, INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets=are;id6I°ud6d ❑ ENV -1C Certificate of Compliance. Required on plans. m MECH-1C Cedificate of Compliance. Required on plans. ❑ LTG -1C Certificate of Compliance. Required on plans. m MECH-2C Air4ater Side/Service Hot Walgq& Pool -Requirements. P— [3LTG-2CLighting Controls Credit Worksheet. m MECH-3C Mechanlcal Ventilation a`nd Reheat ❑ LTG -3C Indoor Lighting Power Allowance. m MECH-5C Mechanical-Equipr" ent'Details. EnergyPro 5. 1 by EnergySoft User Number: 5769 RunCode: 2013-12-21 T17:01:45 ID: Page 3 of 12 PERFORMANCE CERTIFICATE OF COMPLIANCE Project Name Rilin ton Tenant Improvement ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance Energy Component Design Design Margin Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Process Lighting TOTALS 0.06 0.06 0.00 112.08 112.05 0.03 31.06 30.99 0.08 0.00 0.00 0.00 0.00 0.00 0.00 17.57 16.67 0.90 59.47 59.47 0.00 85.90 85.90 0.00 0.001 0.001 0.00 0.001 0.001 0.00 306.13 305.12 1.01 Percent better than Standard GENERAL INFORMATION 0.3%1 ( 0.3 % excludi Part 2 of 3 Heating Cooling Fans Heat Rej Pumps DHW Lighting Receptacle Process Process Ltg BUILDING COMPLIES PERF -1C Date 12/21/2013 Building Orientation (S) 180 deg Conditioned Floor Area 1,648 sqft. Number of Stories 2 Unconditioned Floor Area 0 sqft. Number of Systems 2 Conditioned Footprint Area 0 sqft. Number of Zones 1 Natural Gas Available On Site Yes Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof ; Orientation Gross Area (S) 292 (w) 0 (N) 292 (E) 80 664 1,648 Prescriptive Lighting Power Density Prescriptive Envelope TDV Energy Remarks: Standard 0.850 W/sqft 33,709 Gla7inn Area sqft. sqft. sqft. sqft. sqft. sqft. 18 0 48 18 85 0 Proposed 0.850 W/sqft. 49, 384 sqft. sqft. sqft. sqft. sqft. sqft. Gla7inn Ratin 6.3% 0.0% 16.4% 23.0 12.8 0.0 Prescriptive Values for Comparison only. See LTG -1 C for allowed LPD. CITY OF LA QUI NTA BUILDING APPROVED FORNSTRUCTION DATE _ -- BY PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 C Project Name Rilington Tenant Improvement Date 11212112013 ZONE INFORMATION Floor Inst. Ctrl. Allowed LPD Proc. Area LPD Credits Area Tailored Loads System Name Zone Name Occupancy Type s ft. W/sf' W/sf 2 W/sf s W/sf ° W/sf Undefined System Suite 205 Comp Bldg Office 1,648 "0.850 Notes: 1. See LTG-1 C 2. See LTG-2C 3. See LTG-3C 4. See LTG-4C Items above require special documentation items marked with asterisk see LTG-1 -C by others) (by others EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The locil enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Q 1 1 r,o� �.•0 QAg— EPL � lJ I LLJ' I o � u ••• •• •. g /A r- r- r-A E)V Y_ The exceptional features listed in this performance approach application have specifically been revie ed: Ade u e nen justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp DATE EnefgyPro 5. 1 by EnergySoft User Number: 5769 RunCode: 2013-12-21717:01:45 /D: Page 5 of 12 CERTIFICATE OF COMPLIANCE and (Part 1 of 4) MECH-1 C FIELD INSPECTION ENERGY CHECKLIST Project Name Rilington Tenant Improvement Date 12/21/2013 Project Address 78-145 Calle Estado, Suite 205 La Quinta Climate Zone 15 Total Cond. Floor Area 1,648 Addition Floor Area 0 GENERAL INFORMATION Building Type: ® Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room ❑ Schools (Public School) ❑ Relocatable Public School Bldg. m Conditioned Spaces ❑ Unconditioned Spaces affidavit Phase of Construction: ❑ New Construction ❑ Addition ® Alteration Approach of Compliance: ❑ Component ❑ Overall Envelope TDV ❑ Unconditioned (file affidavit) Energy Front Orientation: N, E, S, W or in Degrees: 180 deg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST E ui ment2 Inspection Criteria Meets Criteria or Requirements Pass Fail — Describe Reason Item or System Tags AC -1 RTU -1 HP -1 DHW Heater [3 13i.e. Equipment T e3: Electric Res DHW Boiler ❑ ❑ Number of Systems 1 ❑ ❑ Max Allowed Heating Capacity' 6,143 Btu/hr ❑ ❑ Minimum Heating Efficiency' 0.98 EF ❑ ❑ Max Allowed Cooling Capacity' n/a ❑ ❑ Cooling Efficiency' n/a ❑ ❑ Duct Location/ R -Value n/a ❑ ❑ When duct testing is required, submit MECH-4A & MECH-4-HERS n/a ❑ ❑ Economizer n/a ❑ ❑ Thermostat n/a ❑ ❑ Fan Control n/a ❑ ❑ E ui ment2 Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Pass Fail — Describe Reason Item or System Tags i.e. AC -1, RTU -1, HP -1 Undefined System ❑ ❑ Equipment T e3 Packaged DX ❑ ❑ Number of Systems 2 ❑ ❑ Max Allowed Heating Capacity' 4 8, 000 Btu/hr ❑ ❑ Minimum Heating Efficiency' 8.30 HSPF ❑ ❑ Max Allowed Cooling Capacity' 47,500 Btu/hr ❑ ❑ Cooling Efficiency' 14.0 SEER / 11.5 EER ❑ ❑ Duct Location/ R -Value Attic, Ceiling Ins, vented/8.0 ❑ ❑ When duct testing is required, submit MECH-4A & MECH-4-HERS '� No { ('u F(7-- —_ —'— ❑ T y � YF L QUIN7A Economizer No Economizer I l I nIRPI; & SAFETY DEMIT. Thermostat Setback Required A rpm �--)\ /� n ❑ Fan Control Constant Volume rn � -.n l o � v T{OPQ 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or fro the building plans) the responsible party shall resubmit energy compliance to include thetccti f s. BY 2, For 3�ditional detailed discrepancy use Page 2 of the Inspection Checklist Form. Complia ail fa Fail'fJoxisscFecked. 3. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, ore . EnergryPro 5. 1 by EnergySoft User Number.' 5769 RunCode: 2013-12-21 T17:01.45 /D: Page 6 of 12 CERTIFICATE OF COMPLIANCE and (Part 2 of 4) MECH-1 C FIELD INSPECTION ENERGY CHECKLIST Project Name Date Rilinaton Tenant Improvement 1 12/21/2013 AIR SYSTEM REQUIREMENTS Project Name Rilington Tenant Improvement Indic Item or System Tags i.e. AC -1, RTU -1, HP -1 Number of Svstems Indicate MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R -value T-24 Sectio. 112(a) 112(a) 112(b), 112 112(c), 115 121 b 121 b 121 c 121 c 122(e) 122(e) 122(f) 122 123 124 PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a & 144(a & 144(a & 144(a & 144(c) 1 44 c 144(c) 144 d 144(e) 144(f) 144(f) 144 144(i) 144(k) Part 1 of Air Systems Type Central, Single Zone, Pac Undefined System 2 Reference on Plans or Schedule and indicate 8.30 HSPF 14.0 SEER/ 11.5 EER Yes n/a No 247 cfm No No Programmable Switch Setback Required Auto n/a Attic, Ceiling Ins, vented /8.0 n/a 59,959 Btu/hr n/a 66,125 Btu/hr Constant volume Yes No No Economizer Constant Temp Constant Temp No ► MECH-2C 77;,-2J2112013 VAV, or etc...) licable APPROVED 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary -heat for Fiea pumps�lf�elec't"ricvheat is explain which exception(s) to §144(g) apply. WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2C Project Name Date Rilington Tenant Improvement 1 12/21/2013 WATER' SIDE SYSTEMS: Chillers, Towers Boilers, H dronic Loops Item or System Tags (i.e. AC-1, RTU-1, HP-1)' Number of Systems Indicate Page Reference on Plans or Specification 2 MANDATORY MEASURES T-24 Sections Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Cooling Tower Fan Controls 144(a & b Cooling Tower Flow Controls 144(h) Variable Flow System Design 144(h) Chiller and Boiler Isolation 144 CHIN and HHW Reset Controls 144 WLHP Isolation Valves 144 VSD on CHW, CW & WLHP Pumps>5HP 144 DP Sensor Location 144 1. The proposed equipment need to match the building plans schedule or specifications. if a requirement is not applicable, put "N/A" in the column next to applicable section. 2. For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column next to applicable section. Service Hot Water Pool Heating Item or System Tags (i.e. WH-1, WHIP, DHW, etc...)' DHW Heater Number of Systems 1 Indicate Pa a Reference on Plans or Schedule' MANDATORY MEASURES T-24 Sections SERVICE HOT WATER Certified Water Heater 111, 113(a) Chronomite Water Neater Efficiency 113(b) 0.98 EF Service Water Heating Installation 113(c) Controls Req. Pipe Insulation 123 Required POOL AND SPA Pool and Spa Efficiency and Control 114(a) n/a Pool and Spa Installation 114(b) n1a w CITY OF LA GUI NTA j Pool Heater —No Pilot Light 115(c) n/a BUILDING & SAFETY DEPT. SpaHeater — No Pilot Light 115 d n/a APPROVED Pipe Insulation 123 n/a FOR CONSTRU TION N 1. The Proposed equipment needs to match the building plans schedule or specifications. If a requirement is not applicable, put "N/A" in the column next to applicable section. 2. For each water heater, pool heater and domestic water loop (or groups of similar equipm'ent)_fill_in_the_refeLenceYto_sheet number-and or specification section and paragraph number where the required features are documented._If_a quirement=is not-applicable,-put�llA�in the column. EnerqyPro 5.1 by Ene Soft User Number.' 5769 Run Code: 2013-12-21717:01:45 ID: Page 9 of 12 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name Rilington Tenant Improvement Date 12/21/2013 MECHANICAL VENTILATION (§121(b)2) REHEAT LIMITATION (§144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N zone/system Condition Areaper ft2 CFM ft2 Min CFM By Area B X C Number Of People Min CFM CFM by per Occupant Person E X F REQ'D V.A. Max of D or G Design Ventilation Air CFM 50% of Design Zone Supply CFM B X 0.4 CFM / ft2 Max. of Columns H, J, K, 300 CFM Design Minimum Air Setpoint Transfer Air Suite 205 1,648 0.15 247 247,247 Undefined System Total 247 247 1> ! M -n -4 ! L ® 1 G) °T1 O0 z -n Q° Totals Column I Total Design Ventilation Air dvlirA mnventilaUon rate per Section 121, Table 121-A. E{ aged on fixed- eat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Rne rw ed�entitat on Air REQ'D V.A. is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS Column D or G). I ist be ceatentan orequal to H, or use Transfer Air column N to make up the difference. JI� Desi n fanjsu I CFM Fan CFM x 50%; or the design zone outdoor airflow rate per 121. J K I Condition—area (M x 0.4 CFM / ft2; or LL -10—ax- of Columns H, J, K, or 300 CFM M This must be less than orequal to Column L and greater than orequal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air Column H and the Design Minimum Air Column M), Column H minus M. EnergyPro 5.1 by EnergySoft User Number: 5769 RunCode: 2013-12-21T17:01:45 ID: Pae 10 of 12 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5C Project Name Rilington Tenant Improvement Date 12/21/2013 CHILLER AND TOWER SUMMARY PUMPS Equipment Name Type Qty. Eff iciency Tons Pump Qty, GPM BHP Control DHW / BOILER SUMMARY System Name Type Vol. Distribution Qty. Rated Input (GalsJ, Energy Factor or RE Standby Loss Tank Ext. or Pilot R-Value Status Chronomite Instant Elec Kitchen Pipe Ins 1 6,143 0 0.98 n/a n/a New MULTI-FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length ft Control Qty. HP Type In Plenum Outside I Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING _ S stem ame Type Qty. Output Aux. kW Efficient Output Efficient Status G ne—dp 4 Ton, 14 SEER Heat P, ump Packaged DX 2 48,000 0.0 8.30 HSPF 47,500 14.0 SEER/ 11.5 EER Existing m -n F —J 0-�N -��ni p 11 n 'Ju rn l C N ALYSTEMiFiAN, 1SUMMARY t"— I SUPPLY FAN RETURN FAN -' Mtem Name Fan Type Economizer Type CFM BHP CFM BHP Gen nc 4 Ton, i.;4•SrERCH6aPPurp Constant Volume No Economizer 800 0.17 none I -4 o I Ene Pro 5.1 by EnemySoft User Number: 5769 Run Code: 2013-12-21717:01.45 ID: Pae 11 of 12 f ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM Project Name Date Rilington Tenant Improvement 12/21/2013 DESCRIPTION Building Envelope Measures: §118(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §118(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §118(f): The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. . §117(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of §116(a) 1: window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors swin inq and sliding), and 1.0 cfm/ft.2 for nonresidential double doors (swinging). §116(a) 2: Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default 1.1 -factor. §116(a) 3: Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §116(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION r EnerPro 5.1 6 Ene Soft User Number: 5769 RunCode: 2013-12-21T17:01.T ID: Pae 12 of 12 2ECEl�E� CERTIFICATE OF COMPLIANCE IJEC 2 4 20, (Page 1 of 4) LTG -1C Project Name: Rilln ton Offices TI Suite 205 CeMM V, � ; 9 v,r,,.. 4�f�la{ Date. 12-23-13 .� Project Address: 78-115 Calle Estado, Suite 205, La Quinta, CA 92253-3913 Climate o Jfrl 15 J fti ding CFA : 1759 Unconditioned Floor Area: General Information Building Type: El Nonresidential High -Rise Residential Hotel/Motel ®Schools Relocatable Public Schools Conditioned Spaces ® Unconditioned Spaces Phase of Construction: New Construction Addition ®x Alteration Method of Compliance: E] Complete Building El Area Category Tailored Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. Name: Alan Darling Signature: Company: Alan L. Darling, PE Date : 12-23-13 Address: If 32230 Calle Balareza CEA CEPE applicable: # # City/State/Zip Temecula, CA 92592 Phone: 951-288-4808 Principal Lighting Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting design. • This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24, Pages 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided. to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name: Alan Darling Signature: Company: Alan L. Darling, PE Phone: 951-288-4880 Address: 32230 Calle Balareza License# E14117 city/state/zip: Temecula, CA 92592 Date: 12-23-13 Lighting Mandatory Measures E0.2 Indicate location on building plans of Mandatory Measures Note Block: LIGHTING COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. LTG -1 C Pages 1 through 4 Certificate of Compliance. All Pages required on plans foN all.subir ttalss. LTG -2C Lighting Controls Credit Worksheet CITY of i I II E] LTG -3C Indoor Lighting Power Allowance BUILDING RA_p_G nr-r� LTG -4C Pages 1 through 4 Tailored Method Worksheet /A 1c) D 0, f -N\ LTG -5C Pages 1 and 2 Line Voltage Track Lighting Worksheet FORC, .. . DATE BY 2008 Nonresidential Compliance Forms July 2010 CERTIFICATE OF COMPLIANCE (Page 2 of 4) LTG -1C INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Project Name: Rilington Offices TI Suite 205 Date: 12-23-13 Installation Certificate, LTG-I-INST (Retain a copy and verify form is completed and signed.) 13 Field Inspector Certificates of Acceptance, LTG -2A and LTG -3A (Retain a copy and verify form is completed and signed.) Field Inspector A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on this Lighting Schedule is only for: JE CONDITIONED SPACE [I UNCONDITIONED SPACE The actual indoor lighting power listed below includes all installed permanent and portable lighting systems in accordance with §146(a) ® Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the calculation of actual indoor lighting power density in accordance with the Exception to §146(a). All portable lighting in excess of 0.2 watts per square./bot is totaled below. Luminaire Schedule (Type, Lamps, Ballasts Installed Watts A B C D E F G H How wattage was Field determined Ins ector2 N w ami F Complete Luminaire Description ¢ • CEC According Q £ c Default to -0 .c . y _ (i.e, 3 lamp fluorescent troffer, 6 from § 130 E :5 - z F32T8, one dimmable electronic ballast) NA8 d ore A 3 LAMP FLUORESCENT 2X4 TROFFER 93 x x; 16 11488 0 B 6" COMPACT FLUORESCENT DOWNLIGHT 31 xM 1 13 403 X LED EXIT SIGN 31 xn 1 9 El El 0 1 El 113 INSTALLED WATTS PAGE TOTAL: 1900 Building total number of pages 1 Installed Watts Building Total 1900 p (Sum of all pages) Enter into LTG -IC Page 4 of 4 L Wattage shall be determined according to Section 130(d and e). Wattage shall be rating of light fixture, not rating of bulb. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action ig-correctr--Verify-buildin _ lans iknecessar .,_ CITY OF LA CivINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE - BY 2008 Nonresidential Compliance Forms July 2010 CERTIFICATE OF COMPLIANCE a e 3 of 4 LTG -1C Project Name: Date: Rilington Offices TI Suite 205 12-23-13 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250ft" automatic daylighting controls for daylit areas > 2, 500 ft2, d) shut-off controls, e) display lighting controls, J) tailored lighting controls - general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic controls or retail stores > 50, 00O.ft2, in accordance with Section 131. MANDATORY LIGHTING CONTROLS - FIELD INSPECTION ENERGY CHECKLIST Field Inspector Type / Description Number of Units Location in Building Pass Fail WALL MOUNTED OCCUPANCY DETECTOR& 5 © ROOMS<200 SF [I El CEILING MOUNTED OCCUPANCY DETECTORS 3 ROOMS > 200 SF 0 ® El MULTI-LEVEL SWITCHING 7 0 NON-SUPPORT AREA>100 C3 13 El 13 ® 13 13 13 Field Inspector's Notes or Discrepancies: DEPT. 2008 Nonresidential Compliance Forms July 2010 CERTIFICATE OF COMPLIANCE (Page 4 of 4) LTG-1C Project Name: Rilington Offices TI Suite 205 177712-23-13 Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Watts Watts Installed Lighting Installed Lighting 1900 from Conditioned LTG-IC Page 2 from Unconditioned LTG-1C Page 2 p Lighting Control Credit Lighting Control Credit Conditioned Spaces from LTG-2C Unconditioned Spaces from LTG-2C _ Adjusted Installed 1900 Adjusted Installed = Lighting Power Lighting Power Complies if Installed <_ Allowed = Complies if Installed <_ Allowed Allowed Lighting Power 1900 Allowed Lighting Power Conditioned S aces from LTG-3C Unconditioned Spaces from LTG-3C Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system, LTG-2A and LTG-3A. The designer is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NA Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG-2A and LTG-3A forms are not considered a complete form and are not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §IO-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the LTG-2A and LTG-3A for each different lighting luminaire controls must be provided to the owner o the buildingfor their records. Luminaires Controlled LTG-2A and 3A Controls and 6. = Sensors and L E Automatic Daylighting Controls Equipment Re uirin Testing Description ' - ° Location Acceptance Wall mounted OCC Occupancy Sensors 5 Rooms < 200sf Ceiling mounted OCC Occupancy Sensors 3 Rooms > 200sf Ply 1 I IIK \J Y '�.I' Y \ r'�1 Ilt 111N 1/1 n I-A1-r' \75 ` -. Y 9 1 / l L7'LJ I I�L/11 V UC V/'�1 -114.. 1 1 1 j-. i-P Y 1 511- I lUIT I DATE BY I 2008 Nonresidential Compliance Forms July 2010 INDOOR LIGHTING POWER ALLOWANCE LTG -3C Project Name: Rilington Offices TI Suite 205 Date: 12-23-13 ALLOWED LIGHTING POWER Chose One Method A Separate LTG -3C must be filled out for Conditioned and Unconditioned Spaces. Indoor Lighting Power Allowances listed on this page are only for: El CONDITIONED spaces ® UNCONDITIONED spaces COMPLETE BUILDING METHOD WATTS COMPLETE ALLOWED BUILDING CATEGORY (From 046 Table 146-E) PER (ft2)X BLDG. AREA = WATTS CATEGORY METHOD — Part A A AREA CATEGORY (From § 146 Table 146-F) Corridors. restrooms. stairs. and su000rt areas Additional Allowed TOTALS I I �_ AREA WA B C D WATTS ALLOWED PER (ft) X AREA (ft) WATTS 0.6 57 34 1.1 1210 1331 1.4 300 420 1.1 i 192 1 211 Area Category Method — Part B from table below TOTALS 1759 �_,9 AREA WA AREA CATEGORY METHOD — Part B Additional Wattage Allowance from Table 146-F Footnotes A B C D E F G Primary Function Sq Ft Additional Watts Per 112 Allowed Wattage Allowance x C Description(s) and Quantity of Special Luminaire 2 Types in each Primary Function Area Total Design Watts ALLOWED WATTS Smaller of D or F TOTALS — Enter into Area Category Method — Part A (table above) ' Additional watts available only when allowed according to the footnotes on bottom of Table 146-F for chandelier or sconce; art, craft, assembly or manufacturing specialized task work; precision commercial/ industrial work; or lab specialized task work. 2. Special luminaires are light fixtures described in the Table 146-F Footnotes that are subject to an additional wattage allowance. TAILORED METHOD I %-I, I i 'U F L_/A Q U I N i /�► Total Allowed Watts using the Tailored Method taken from LTdkd.FEageJGQ4) SAPET Y DEPT. The indoor lighting power allowance using the Tailored Method of compliance sh all be delle, ii s & HT � set of forms. A separate set of LTG -4C forms shall be filled out for CONDITIONED and UN CONDItT10NEEtisoace%--..,.�. I DATE BY 2008 Nonresidential Compliance Forms