Loading...
07-0879 (SOTB)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tdtt 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: Rlff07-00000879 Property Address: 81255 LEGENDS WY APN: 762-420-028- - - Application description: STRUCTURES OTHER THAN BUILDINGS Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 4000 Applicant: I hereby affirm under penalty of pe Section 7000) of Division 3 of the License Class: C8 C27 C29 Architect or Engineer: P(A -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ;ED CONTRACTOR'S DECLARATION icensed under provisions of Chapter 9 (commencing with >r fessionals Code, and my License is in full force and effect. License No.: 656128 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury thal I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business an J Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repai any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or he is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided -that the improvements are not intended or offered for sale. If, however,, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed • pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT- Owner: JACKSON 1� 81255 LEGENDS WAY �D LA QUINTA, CA 92253 Contractor: TESERRA P.O. BOX 1280 COACHELLA, CA 92236 (760)398-9222 Lic. No.: 656128 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/23/07 -7 9p: �. r1 MAR 2 E 237 ------------7---------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is � issued. t`1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the rk for which this permit is issued. My workers' compensation insurance carrier and policy numb r are: Carrier SEABRIGHT olricy Number BB1070510 _ I certify that, in the performance of he work for which this permit is issued, I shall not employ any person in any manner so as c subject to the workers' compensation laws of California, and agree that, if I should eco a subj t to the workers' compensation provisions of Section 3700 of the Labor Code, shall orthwith omply with those provisions. WARNNG: FAILURE TO SECURE WORKERS'OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENAgTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE OST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTERE T, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under pursuant to any permit issued as a result of this application, the owner, and the applicant, each agre o, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and em to ees for any act or omission related to the work being performed under or following issuance o thi permit. 2. Any permit issued as a result of this a ati mes null and void if work is not commenced within 180 days from date of issu ce suc perm or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and to the the ove infor tion is correct. I agree to comply with all city and county ordinances and state laws rel ting to uildin c nstructi n, and hereby authorize representatives of this codpty to entgr uponthe above -menti n ro rty f r i . n purposes. or i Application Number . . . . . 07-00000879 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 63.00 Plan Check Fee 40.95 Issue Date . . . . Valuation 4000 Expiration Date 9/19/07 Qty Unit Charge Per Extension BASE FEE 45.00 2.00 9.0000 THOU BLDG 2,001-25.,000 ------------------- 18.00 . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 17.25 Plan Check Fee 4.31 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/19./07 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 ----------------------------------------------------------------------------- 2.25 Special Notes and Comments BBQ - ANSI Z21-58-1995, FIREPIT AGAL496 ----------------------------------------------------------7 ----------------- .Other Fees . . . . . . . . . ENERGY REVIEW FEE 4.10 STRONG MOTION (SMI) - RES .50 Fee summary Charged Paid Credited ---------- Due ---------- ---------- ---------- Permit Fee Total 80.25 .00 .00 80.25 Plan Check Total 45.26 .00 .00 45.26 Other Fee Total 4.60 :00 .00 4.60 Grand Total 130.11 .00 .00 130.11 . ..,. LQPEBMTf #4'TIE -STEEL AT 36" DIAM. TOP COURSE WATERPROOF GAS FIRE RING:INSIDE DIMENSION MEMBRANE I.C.B.O. # (TYP. INTERIOR ANSI SURFACES) BTU _.7 c��G> VE BAR VERT AT U.L. APPROVED. 32" O.C. (TYP.) 7A 7B LENGTH OF GAS PIPE -- ` 6x8x8 OR 8X8X8 CMU DIAM. OF GAS PIPE"'=.._.�; =� — SOLID GROUT 7 OUTDOOR FIRE RING 1/2"=1'-0° GAS- SHUTOFF GAS LINES SHALL BE INSTALLED VALVE GRAVEL PER CPC FOR DEPTH, LOCATED GAS LOG COURSE WATER PROOF COVERAGE, AND PLACEMENT. WITHIN 36" OF UNIT LIGHTER MEMBRANE ' (TYP.) STONE CAP #4 TIE STEEL ' #4 BAR VERT. AT 32" O.C. 8x8x8.CMU; SOLID GROUT � F.S. a� A ' F.S. N Y Y " 3u CLR METAL GAS RISER GRAVEL SUMP 3, CU. FT. 2" DRAIN OR PROVIDE 12" DIAM. CRUSHED ROCK OPENING IN FOOTING - 7A OUTDOOR FIRE RING - STONE CAP STAINLESS GRILL (� STEEL LIGHT SINK "' PROVIDE VENT, WASTE, AND i TONE OR PLUMBING FOR SINK ON SEPARATE TILE CONSTRUCTION DOCUMENT. �i COUNTER i O O O O — I le/ GFI REF. / �I OUTLET PRE-HUNGO O /' LIGHT S.S. DOORS 1 STUCCO OR SWITCH \ VENEER (WATERPROOF) .----_------------ ------------------- -- —Q ?•',.�- -tea- Y_��=T"�___�f --LENGTH VARIES -BB - I.C.B:O. # ANSI #_`Z -t- -7;L- 1961 S FREE-STANDING OUTDOOR KITCHEN - FRONT ELEVATION BTU 932 , r%r� U.L. APPROVED. LIGHT I a GRILL REF. ' SINK ADAPT DIMENSIONS DIMENSIONS ,! n l FREE-STANDING OUTDOOR KITCHEN'- PLAN. TO FIT APPLIANCES 1/Z"=1'-0" 6x8)(16 CMU; GROUT.CELLS WITH STEEL _#4 BARS VERT. AT 24° O.C. (TYP.) w BBQ LAYOUTS MAY VARY. a FOOTING SIZE & REINF. ARE TYPICAL. . • IC LENGTH VARIES n FREE-STANDING OUTDOOR KITCHEN - FOt INDATION PLAN c' A".C. ONE CAP, TILE M,POURED CONC. 4 BAR HORIZ. AT 2" O.C. (TYP,) 16 CMU T CELLS WITH STEEL AR . AT (TYP•)• 4 BARS HORIZ. CONT. 6"- .ARIES 6'' n FREE-STANDING BBQ - WALL SECTION • I i D BBQ ISLAND - SIDE ELEV.