08-0583 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 08-00000583 55527 FIRESTONE 775-151-004- - - REMODEL - RESIDENTIAL LOW DENSITY RESIDENTIAL 8726 Tiht 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: �IA LIC ED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that a licensed under'provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busines an rofessionals Code, and my License is in full force and effect. License Class: Bl License No.: 594043 ate• _.16'�i ntractor: 7./ NER-BUILDER DECLARATION I hereby affirm under penalty of perjur that I a xempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Pr fessions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. I , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). ' Lender's Name: Lender's Address: LQPERMIT Owner: TODD FELTZ 101 S. 108 AVE OMAHA, NE 68114 Contractor: 7C'S CONSTRUCTION & 48236 VISTA DE NOPAL LA QUINTA, CA 92253 (760)564-5811 Lic. No.: 594043 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/27/08 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work f which this permit is issued. My workers' compensation insurance carrier and policy number e: Carrier EXEMPT licy Nu ber EXEMPT I certify that, in the performance the wor for which this permit is issued, I shall not employ any person in any manner so as become bject to the workers' compensation laws of California, and agree that, if I should b comes jest to th orkers' compensation provisions of Section ,p 3700 of the bor Code, hall hwith com y with those provisions. atf7 e: Jdt0 �� pplicant:017 WARNING: FAILURE TO SECURE/DE. KERS' CO SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIL PENALTIE AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR C INTEREST. AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit 2. Any permit issued as a result of this applicatio comes II and void if work is not commenced within 180 days from date of issuance of s h permit, or ssation of work for 180 days will subject permit to cancellation. - I certify that I have read this application and state tha the above infor ation is ct. I agree to comply with all city and county ordinances and state laws relating t building cons ction, a he eby authorize representatives of this my to enter upon the above-mentioned open pe do p ses. ate• r _A-4 Signa tur Applicant or AgenAp Application Number . . . . . 08-00000583 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 108.00 Plan Check -Fee 70.20 Issue Date . . . . Valuation . . . . 8726 Expiration Date 11/23/08 Qty Unit Charge Per Extension BASE FEE 45.00 7.00 9:0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 63.00 Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 18.82 Plan Check Fee 4.71 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/23/08 Qty Unit Charge Per Extension . BASE FEE 15.00 109.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 3.82 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/23/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 ---------------------------------------------------------------------------- EA MECH APPL REP/ALT/ADD 9.00 Permit .. PLUMBING Additional desc . Permit Fee . . . . 21.00 Plan Check Fee'. 5.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/23/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ENCLOSE ATRUM TO OFFICE 109 SQ. FT.DEN NEXT TO OFFICE SHALL NOT BE USED AS A SLEEPING ROOM, PER OWNER. LQPERMIT LQPERMIT Application Number . . . . . 08=00000583 ----------------------------------------------------------------------'------ Other Fees . . . . . . . ENERGY REVIEW FEE 7.02 STRONG MOTION (SMI) - RES. .87 Fee summary ----------------- Charged ---------- Paid - Credited -------------------- Due Permit Fee Total 171.82 .00 ---------- .00 171.82 Plan Check Total. 86.16 .00 .00 86.16 Other Fee Total 7.89 .00 .00 7.89 Grand Total 265.87 .00 .00 265.87 LQPERMIT ■ — Bin#. City of La. Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quints, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # ��� �^ Project Address:'�jSS 2jt�-T'm Owner's Name: A. P. Number: -775 / S l bD e�. Address: /42l Legal Description: V 1 f —r 1015 G/K o5 ef City, ST, Zip: iP jvt •a �Ia N 6 . 6£3 ! $ �}• ZL Contractor: p �' (,( � Address: Telephone: Project Description: City, -ST -,Pp. Telephone: M V� P State Lie. # : City tic. #: nnnsk Arch., Engr., Designer: Leoic-a t�i a ccoo s"CJ l .I Address: . Q• _4960 _ J City, ST, Zip: �.. u�iA (.{► , ej Z 2 �• Telephone: '71� • $-• jQ(,(o State Lit. #: Name of Contact Person: t (.6��e,� Construction Type: Occupancy: Project type (circle one): New A d'n Iter. Repair Demo Sq; Ft: # Stories:. # Units: Telephone # of Contact - Estimated Value.ojProject: '� ZQ �o APPLICANT: DO NOT WRITE BELOW THIS LINE .. # Submittal Req'd Reed TRACKING. PERMTT FEES Plan Sets v Plan Check submitted Item Amount Structural Calcs. Reviewed; ready f r correction Plan Check Deposit Truss Calcs. Called Contact Person Yt Plan Check Balance Energy Calcs. Plans picked up Construction ' Flood plain plan , Plans resubmitted Mechanical Grading plan' 2" Review, ready or correctio sue Electrical , Subcontactor List Called Contact Person 4A Plumbing Grant Deed Pians.picked up S S.M.I. H.O.A. Approval Plans resubmitted 20 Grading IN HOUSE: 'a Review, ready for correctionissue .51.2-3 Developer Impact Pee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Total Permit ees �( 2J pinN'S a5 b1�.��Czc4 i'c�a�►s . � �� �5s tet, . to S cti.00( F6Es o ca(' 20 (To iz i N r'o /LP'1 III tp ,.> 4 Date 5/27/08 No. 30054 Owner Feltz Address 55527 Firestone City La Quinta Zip 92253 Tract # Type Residential Addition Lot # No. Street Unit 1 55527 Firestone Unit 2 Unit 3 Unit 4 Unit 5 Comments CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 S.F. 109 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 4�J��F�scyo BERMUDA DUNES r rn RANCHO MIRAGE INDIAN WELLS d� PALM DESERT y LA QUINTA �INDIO y� APN # 775-151-004 Jurisdiction La Quinta Permit # No. of Units 1 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 109 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Larry Koia Check No. Name on the check Telephone 831.5212 Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collectec Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this ll erve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original- Building Department Applicant Copy- Applicant/Receipt Copy -Accounting Payment Recd $0.00- �Ghier/Under ;Jti NOTICE: Pursuant to Government Code Section 66020(d)(1), this ll erve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original- Building Department Applicant Copy- Applicant/Receipt Copy -Accounting i I. - TITLE 24 REPORT C 6, /COP/ Title 24 Report for: McNaboe Residence 55-527 Firestone La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 Job Number: APR 0 9 2008 Date: 4/8/2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED FOR CONS,,TR TION VrogS DA aY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 EnergyPro 4.4 by Energy5oft Job Number: User Number: 2655 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R �IlcNabn_Sidence 2,381 ft2 ❑ Multi Family [X] Existing + Add/Alt Existing Floor Area: 4l_812QQ8 Project Title 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: Date _55-527 F_ir_estone-La_Quinta Fenestration: Average Ceiling Height: 9.0 ft Project Address 1.00 Ratio: 18.3% Avg. SHGC: 0.70 Number of Stories: Building Permit # 1os_u-f_o[m,-1 BUILDING ZONE INFORMATION # of Thermostat (760) 779-0657 Zone Name Floor Area Volume Units Zone Type Documentation Author Hgt. Area -Living-Zone 2,38a -21,_429 100_ Conditioned- Telephone Plan Check/Date �aeL 10 O CAA_CJimatel0nes5 Location / Comments Field Check/Date Compli ce Method .Root- Wood_ 484_ _0_025_ -R38_ --R-0_0 _315_ 0 X ❑N.ew _01A18 Climate Zone TDV Standard Proposed Compliance LivingZone _(kBtu/sf-yr) Design Design Margin _V_1LaIL- Wood_ 22 _0 11.0_ -Rd1 __ZO_0_ _995 --go IX ❑ New _0.9-A2 Space Heating 3.51 3.08 0.43 Space Cooling 176.61 148.03 28.58 LivingZone Fans 23.88 19.98 3.90 Roof- Wood- -2,240_ _0_049_ -R1.9.0`0_0_ _9.00 IN ❑❑Altered- _01 A_4_(E=_OJA4.)_ Domestic Hot water 11.78 11.78 0.00 Pumps 0.00 0.00 0.00 Totals 215.78 182.87 32.91 ❑ ❑ Percent better than Standard: Building Type: Single Family ❑ Addition Total Conditioned Floor Area: 2,381 ft2 ❑ Multi Family [X] Existing + Add/Alt Existing Floor Area: 2,272 ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,381 ft2 Fenestration: Average Ceiling Height: 9.0 ft Area: 436 ft2 Avg. U: 0.87 Number of Dwelling Units: 1.00 Ratio: 18.3% Avg. SHGC: 0.70 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area -Living-Zone 2,38a -21,_429 100_ Conditioned- -Setback_ 2 -nla OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments wall- Wood- X90_ _01.02 R-13_ X0_0_ 0 9.0 1X 1-1 New- - -4 Addition .Root- Wood_ 484_ _0_025_ -R38_ --R-0_0 _315_ 0 X ❑N.ew _01A18 Addition Wall_ Wood_ x_66_ _0..]10_ _EZ1_1 _F3_0_0_ 9A_ 9.0 IX ❑ Existing- _0.9 A2 Livinglon.e a1�L II Wood- 92 _0110_ -R-11_ _R_ -O_0_ _.35_ 9.0 IX ❑ New _0.9_A2 LivingZone 1Lya1l_ Wood_ x_0.8_ 01J0_ _R11 -FL-0-0-X80 90 IX ❑Existing_ _0-9-A2 LivingZone _V_1LaIL- Wood_ 22 _0 11.0_ -Rd1 __ZO_0_ _995 --go IX ❑ New _0.9-A2 Living - Zone --Wall- Wood- x.01 _0110_ -R,1 X0_0_ _=0__9.0 X ❑ Existing_ _0.9-A2 Living -Zone -Wzll- Wood- 923_ -0110_ R-11 X0_0_ 0.9.0 [X El New- _0.9-A2 Living -Zone YUI Wood_ 30 _0110_ R-11 __P_0_0 ___A5 90 [X ❑New 09-A2 LivingZone W,gII_ Wood_ 30.0_ _0 11 -11 0_ __R _EZO_0_ 0 9.0 [X El Removed- _Q9- Liming -Zone Roof- Wood- -2,240_ _0_049_ -R1.9.0`0_0_ _9.00 IN ❑❑Altered- _01 A_4_(E=_OJA4.)_ Living -Zone ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ 0 E EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Pape:3 of 11 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R McNaboe Residence Status Overhang Left Fin Right Fin # 4/8/2008 Project Title Hgt. Wd. Len. Date REA Dist. Len. Hgt. Dist. Len. Hgt. FENESTRATION SURFACES None 1.00 2 True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments _- _Skyligbt_Rea>-(Nl/_V)_8.0_ -0_87-0-NERC _0_Z0 -NERD _315_ 0.76 _0_ New Double-Mtl_Uncoated_Defa.ult _Additio.n 2 Window Front (E) 7.5 0.870 NFRC 0_70 NFRC 90 90 Existin -Double Mtl Uncoated Default Living Zone 3 Window Front (EZ 25.6 0.870 NFRC 0_70 NFRC 90 90 Existing -Double Mtl Uncoated Default Living Zone 4 Window Front (E_ 64.0 0.870 NFRC 0_70 NFRC 90 90 RemovedDouble Mtl Uncoated Default Living Zone 5 Window Front (E) 20.8 0.870 NFRC 0_70 NFRC 90 90 Existin -Double Mtl Uncoated Default Living Zone 6 Window Front (SE) 10.0 0.870 NFRC 0_70 NFRC 135 90 Existin _Double Mtl Uncoated Default Living Zone L Window Front �$E) 7.5 �$� NF 0.70 NSC 90 Exi in _Double Mtl UaEoated DeJ-ault Living Zone 8 Window Left (SZ 20.8 0.870 NFRC 0.70 NFRC 180 90 Existing_Double Mtl Uncoated Default Living Zone 6 Win ow Left0.870 NFRC 0.70 NERC 1$0- 9Q Existin _Double Mtl Unco-ate Dgfault Living Zone 10 Window Le (S) --W-O NFRC 0_70 NFRC 18Q 90 Existin _DQ bible Mtl Unc-wted QefaulL- Living ZQ_ne 11 Window Left( 7.5 0.870 NFRC 0_70 NFRC 225 90 Existin -Double Mtl Uncoated Default Living Zone 12 Window Rear (W) 45.0 0.870 NFRC 0_70 NFRC 270 90 Existing -Double Mtl Uncoated Default Living Zone J3 -Window ­Rear (Wl _96Q 087-0 NEC -0.7-0 -NERC _27_0_ 2.0 90 Existing_Dou.ble-Mll_Uncoated_Defau.lt _Living_Zone 14 Window Rear CW� 40.0 0.870 NFRC 0_70 NFRC 270 90 Existin -Double Mtl Uncoated Default Living Zone 15 Window Rear (WL 17.7 0.870 NFRC 0_70 NFRC 270 90 Existing_Double Mtl Uncoated Default Living Zone 16 Window Rear (W) 64.0 0.870 NFRC 0_70 NFRC 270 90 RemovedDouble Mtl Uncoated Default Living Zone 17 Window Right N 7.3 0.870 NFRC 0_70 NFRC 0 90 Existin _Double Mtl Uncoated Default __L[ying Zone 18 Window Right (N) 48.0 0.870 NFRC 0_70 NFRC 0 90 RemovedDouble Mill Uncoated Default Living Zone 19 Window Rig_ht_(NE) 104 x$7_0 NFR _ Q 7Q NFRC 90 Exis in Double Mtl Unroate Default Living Zonis 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Status Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 5.0 1.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 7.0 3.8 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 8.0 -8J0 2.0 0.1 _2. 2.0. 5 Bug Screen 0.76 5.0 4.2 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 2.0 2.Q -0-1 2.0 2.0 7 Bug Screen 0.76 5.0 1.5 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 5.0 4.2 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 5.0 4.2 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 5.0 1.5 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 8.0 12.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 3.8 4.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 3.6 2.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 5.0 1.5 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location JA IV Reference Slab Perimeter 18 None No Insulation 26-A1 Slab Perimeter 95 None No Insulation 26-A1 Condition Location/ Status Comments New Addition Existing Living Zone Run Initiation Time: 04/08/08 11:45:30 Run Code: 1207683930 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CFA R McNaboe Residence 4/8/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 20. _SkyliX6...0_—0_87_0_NFRC _O.ZO _ERC _90- —0_ NewDouble_Mtl_Uncoated-Default _Living_Zone 21 Skylight Front (E 16.0 0.870 NFRC 0_70 NFRC 90 0 Existin _Double Mtl Uncoated Default Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 None 1.00 Ti None 1.00 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length R -Val. Insulation Location Condition JA IV Reference Status Location/ Comments Run Initiation Time: 04/08/08 11:45:30 Run Code: 1207683930 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:5 of 11 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R McNaboe Residence 4/8/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Central Furnace 78% AFUE Split Air Conditioner 10.5 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Living Zone Ducted Ducted Attic 2.1 Existing No Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name .Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (°!o) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length_ Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or O rtes' (prr Busine # P ofessions Code) Documentation Author Name: �i✓ 7< �N !/ Name: Joan D. Hacker Title/Firm: K S� Its / Title/Firm: Insu-form, Inc. Address: p . Address: 41-921 Beacon Hill, Suite A 2 Palm Desert, CA 92211 Telephon (� Lic. #: v Telephone: _ 7( 60) 779-0657 Z re) (date) (sig (date) ement Agency 9 Y Name: Title/Firm: Address: Telephone: (signature) I EnerovPro 4.4 by EneravSoft User Number: 2655 Job Number Paae:6 of 11 1 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R McNaboe Residence 4/8/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justitication and documentation submitted. Plan Field The HVAC System "Existing" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a Plan I Field I EneravPro 4.4 by EnemvSoft User Number: 2655 Job Number: Page:7 of 11 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ' ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include F-1 ER El Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:8 of 11 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181,, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723, If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑x ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑X ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ o ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specked criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are, controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that dbes not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ n ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:9 of 11 MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE McNaboe Residence 4/8/2008 SYSTEM NAME FLOOR AREA Living Zone 2,381 Number of Systems 1 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sgft) 29.4 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 24.8 Total Output (sgft/Ton) 484.3 Air System CFM per System 1,740 Airflow (cfm) 1,740 Airflow (cfm/sgft) 0.73 Airflow (cfm/Ton) 353.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 3,666 50,743 3,427 1,134 37,244 0 .. 11,970 6,424 0 0 0 0 0 0 0 0 0 11,970 6,424 74,6:8:3[:3 427 50 091 Existing 48,026 6,024 70,000 Total Adjusted System Outputx8,026 6,024 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2pm 1 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 66.5 OF 66.5 OF 104.3 OF .. Supply Air Ducts Outside Air 0 cfm 100.9 of Supply Fan Heating Coil 1740 cfm ROOMS 70.0 of 66.5 of Return Air Ducts c I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 84.5 / 66.5 OF 84.5 / 66.6 OF 58.5 / 57.0 OF 0 Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 65.0 / 59.4 of 1740 cfm ROOMS 48.5% R.H. 84.5/66.5 of OF F h Return Air Ducts `i EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Pa9e:10 of 11 FROOM LOAD SUMMARY PROJECT NAME McNaboe Residence DATE 4/8/2008 SYSTEM NAME Living Zone FLOOR AREA 2,381 ROOM LOAD SUMMARY ROOM COOLING PEAK - COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 361 4,996 884 361 4,996 884 80 2,612 Living Zone Existing Living 1 3,305 45,746 2,543 3,305 45,746 2,543 1,054 34,632 PAGE TOTAL 3,666 50,743 3,427 1,134 37,244 TOTAL 1 3,666 50,743 3,427 1,134 37,244 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page: 11 of 11