9803-180 (RER)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
R Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
`Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
7Date Signature of Contras,
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business R. Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
tut ti1.'.I'A ii yriif I 13 n A�1J5�i^
(This section need not be completed if the permit valuation is for $100.00 or less):
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to'be ocme subject to the
workers' compensation laws of California, and agree that if I should become
subject to 6efworkers' compensation provisions of Section 3700 oAthe Labor
Code, I shall forthwith comply with those provisions.
bate: / ` Applicant `1
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter,,upon
the�above-mentioned property for;inspedon purposes. j
t,Signature (Owner/Agent) Date
BUILDINGPERMIT PERMIT# " CONTROL#
DATEfit_ ! �� r VALUATION $911 M LOT TRACT 7 n o 7
JOB SITE { ` l,4 APN 4J
ADDRESS ;+;x.900 VIA, CA-RANA,1 fs Nr at➢i! E}li+
OWNER qts CONTRRACTOI)Ry/ DESIGNER ENGINEER
/4ENIGINEERi r�
{'. Li i. .i •i S'.,i��i` �,J% Svr i;ltJ.E i.l :ttrr a.i Vt�d: i.�.` 1, NNe7'�i�A X,- , t�i�J v . 1 .
P.O. BOX 1716 7929:5 RANCHO i,el QUIN1.A DR.
LA. QjANTA C.A. 92253 .LA CgUt-19TA ' f A. 92253 i
c ,11
USE OF PERMIT PA'
AD0 6040 SKY4,10iff IN iV1AS.(@q 610 (4 APR 0
NTV nF 'U"'k QUINTA
J 'VOSI 01 COM" " RUC A f
Feil+;.10��•R�.i 2+d!;ii >S i����)`]�: �..Cl �'
P1. r`►N!"1HPIC K I'' E 101410-1139-318
f70N.`i"11RI; -FIFON PVT! 14 I -WO -.091100
4srm $.50
(NSPRL.iE:"1WivSAND1'JANf'tdT11"
LESS P.PJ!,PAJ.-D VEES
P
RECEIPT I DATE I BY � I DATE FINALED - I INSPECTOR
924.00
$,1175
SO.00
S41.75
�%.
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
I INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas.Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
1
Final
Utility Notice (Perm)
TITLE 24� REPORT, FOR
PALACIO PLAN 1 WITH GUEST BEDROOM
LOT :1 -
.
RANCHO LA' QUINTA, . CA.
PROJECT DESIGNER:.;
SPARKS CONSTRUCTION
79-295 RANCHO LA QUINTA:DR.
LA QUINTA, CA.
(760) .771=1941. .
REPORT -PREPARED BY:..
R :Known, CEPE 90-40-18
KROWN MECHANICAL DESIGN
P,.O.BOX 1761
LA QUINTA, CA,92253-
( 619) 773-2623
Job,Number: 98016
Date, '3/4/1998
The COMPLY 24 computer program has been used to.'perform
tle calculations
summarizedin this compliance report. This program has
approval and is
authorized by the California Energy Commission -for use
with both the
Residential and Nonresidential Building Energy Efficiency
Standards.
This program .developed by Gabel. Dodd Associates ( 510)
426-0803
Table -Of. Contents for Title 24 Report
Cover Page ........ 1
Table of Contents ....... ----- - ---.. 2
Form CF -1R Certificate of -Compliance: Residential ...... ... 3
Form MF -1R Mandatory Measures Checklist: Residential ................. 5
Form C -2R Computer Method Summary ........... ... ."............. 7
Form CF -6R Installation Certificate: Residential ..... ......:....... 10
CERTIFICATE OF COMPLIANCE: Residential (part 1 of 2) CF --1R page 3 of 10
------------------------------------------------- -------------------------
Project Name: PALACIO PLAN 1 WITH GUEST BEDROOM ;Da -e: 3/4/1998
Address: LOT 1
RANCHO LA QUINTA, CA. ;Building Permit No
Designer: SPARKS CONSTRUCTION
Checked by / Date
Documentation: KROWN MECHANICAL DESIGN ;C6HPLY 24 User 2366
---------------------------------------------------------------------------
GENERAL INFORMATION
Compliance Method: COMPLY 24 version 4.11
Climate Zone: 15
Conditioned Floor Area: 3465 sgft
Building Type: Single Fam Det
Building Front Orientation: 150 deg (SE)
Number of Dwelling Units: 11
Floor Construction Type: Slab' on Grade
BUILDING SHELL INSULATION
Component U -Value Location/Comments
------------------------------ ------------------ -----------------
R-13 + 1" Falcon Foam 0.061 LIVING ZONE & DEN
Solid Wood Door 0.387 LIVING ZONE & DEN
R-13 Partition (2x4.16) 0.085. LIVING ZONE & DEN
R-13 + 1" Falcon Foam 0.061 BEDROOMS
R-13 Partition (2x4.16) 0.085 BEDROOMS
Solid Wood Door 0.387 BEDROOMS
R-13 + 1" Falcon Foam 0.061 GUEST BEDROOM
Solid Wood Door 0.387 GUEST BEDROOM
.R-13 Partition (2x4.16) 0.085 GUEST BEDROOM
Tile/Air Sp./R-30/Gypbd 0.029 LIVING ZONE & DEN
Tile/Air Sp./R-30/Gypbd 0.029 BEDROOMS
Tile/Air Sp./R-30/Gypbd •0.029 GUEST BEDROOM
Slab Perimeter w/R-0.0 0.720 LIVING ZONE & DEN
Slab Perimeter w/R-0.0 0.900 LIVING ZONE & DEN
Slab Perimeter w/R-0.0 0.720 BEDROOMS
Slab Perimeter w/R-0.0 0.900 BEDROOMS
Slab Perimeter w/R-0.0'• 0.720 GUEST BEDROOM
FENESTRATION Shading Devices Frame
Orient. Area U -Val TypeInterior Exterior OH SF Type
--------- ------ ----- ------------------------------------ -- -- -----
Back (N) 30.0 0.57 Double Std Drape Standard Bug Scr Y N Vinyl
Back (N) 21.0 0.57 Double Opaque White R1 Standard Bug Scr Y' N Vinyl
Backe (N) 9.0 0.60 Double Opaque White R1 Standard Bug Scr N N Vinyl
Right (NE) 24.0 0.55 Double Std Drape Standard.Bug Scr Y N Vinyl
Right (NE) 15.0 0.55 Double Opaque White Rl Standard Bug Scr Y N Vinyl
Right (NE) 26.5 0.57 Double Std Drape Standard Bug Scr Y N None
Right (NE) 38.5 0.60 Double Std Drape Standard Bug Scr Y N Vinyl
Right (E) 9.0 0.57 Double Opaque White R1 Standard Bug Scr Y. N.Vinyl
Right (E) 15.0 0.60 Double Opaque White Rl Standard Bug Scr• Y N Vinyl
Front (SE) 21.0 0.55 Double Opaque White Rl Standard Bug Scr Y N Vinyl
Front (SE) 8.0 0.57 Double Std Drape Standard Bug Scr Y N None
Front (SE) 18.0 0.57 Double Std Drape Standard Bug Scr Y .N Vinyl
Front (SE) 48.0 0.57 Double Opaque White Rl Standard Bug Scr Y N Vinyl
Front (SE) 17.5 0.60 Double Std Drape .Standard Bug Scr Y N Vinyl..
Front (S) 6.7 0.57 Double Std Drape Standard Bug Scr Y N None
Front (S) 9.0 0.57 Double Opaque White R1 Standard Bug Scr Y N Vinyl
Front (S) 15.0 0.60 Double Opaque White R1 Standard Bug Scr Y N Vinyl
Left (,SW) 105.5 0.55 Double Opaque White Rl,Standard Bug Scr Y N Vinyl
Left (SW)' 8.0 0.57 Double Std Drape Standard Bug Scr Y N Vinyl
P
Lett (SW) 36 .0 O-.5/ Double Opaque.Wnite Kl btanaara bug bcr Y N vinyl
Left (SW) 37:5 0.60 Double Std Drape Standard Bug Scr Y N 'V1 " nyl
Left (5W) 15.0 0.60 Double Opaque White.R1 Standard Bug Sc.r.Y' N`Vinyl
Back (NW) 64.0 0.55 Double. Std Drape Standard Bug.Scr Y N •Vinyl
Back (NW) 58.5 0.55 Double Opaque White:Rl Standard Bing Scr Y' N Vinyl,
Back (NW) 65.0. 0.57 Double Std Drape Standard Bug Scr Y N Vinyl,
Back (NW) 110.0 'O .57• Double Opaque White' Rl Standard Bug Scr Y N Vinyl
'Back (NW) 32.5 0.60 Double Std Drape Standard Bug Scr 'Y, N. Vinyl
Back -'(,NW) 25.0 0.60 Double `Opaque White R1 Standard Brag Scr N N Vinyl
Skylight 24.0 0.80 Double none none N N.Metal
THERMAL MASS Area Thick:
Type Covering ( sf ) (in') Location/Desc`--iption .
. w Y -
Concrete, Heavyweight 'Covered 1253 3.50.. Slab on Grade
Concrete, Heavyweight Exposed .410 3.50, Slab on Grade
Tile in Mortar Exposed 238 0'`75 LIVING ZONE &. DEN/Int .Mass•
Concrete, Heavyweight Covered 1251 3.50 Slab on Grade .`
Concrete, Heavyweight Exposed, 121 3.50` Slab on Grade
Concrete, Heavyweight Covered 430 3.50 Slab on Grade
CERTIFICATE OF
COMPLIANCE. Residential (part 2 of 2).
-----------------------
CF -IR
page 4 of 10
-------------------------------------=--------------
Project Name:
PALACIO PLAN 1 WITH GUEST BEDROOM
;Date:
3/4/1998
Documentation:
---------------------------------------=--------------------------------------
KROWN MECHANICAL DESIGN
;COMPLY
24 User 2366
HVAC SYSTEMS Minimum Distrib Type
System Type Efficiency and Location
Furnace 0.801 AFUE Ducts in Attic
SpltAirCond12.000 SEER Ducts in Attic
Furnace .0-800 AFUE Ducts i'n Attic
SpltAirCond12.300 SEER Ducts in Attic
Furnace 0.801 AFUE Ducts in Attic
SpltAirCond10.800 SEER Ducts in Attic
Duct TStat
RVal Type Location/Comments
4.2 SetBck FAU/CU/COIL 1
4.2 SetBck
4.2 SetBck FAU/CU/COIL 2
4.2 SetBck
4.2 SetBck FAU/CU:/COIL 3 '
4.2 SetBck
WATER HEATING SYSTEMS
System`Name Distribution Type
AMERICAN APP G52 -75T57 Recirc-Time&Temp
AMERICAN APP G52-3OT33- Standard
Water
No.
AFUE
Tank
Ext.
Heater
in
Enargy
Size
Insul
Type
Sys
Fa -'tor
(gal)
R -Val .
StorGas
1
0.51
75.0
12.0
StorGas
1
0.60
30.0
.0.0
SPECIAL FEATURES/REMARKS"
SHADES ON KIT,NOOK,BAR,LIV,FAM&DINE (EX TRANSOM &TOP OF #58)
'A Zonally Controlled -HVAC System which meets CEC criteria has been assumed
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building featureE and.performance
specifications needed to comply with Title 24, Parts 1 & E of the Califor
n'ia Code of Regulations,,and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
( Per Business & Professions Code)
SPARKS CONSTRUCTION
79-295 RANCHO LA QUINTA DR.
LA QUINTA, CA.
( 760 ) 771-1941 Lic #: 7
749
( ature) date)
ENFORCEMENT AGENCY
Name:
Title
Agency:
Telephone:
DOCUMENTATION AUTHOR
R.Krown, CEPE 90-4018
KROWN MECHANICAL DESIGN
P.O.BOX 1761
LA QUINTA, CA 9253
( 619) 773-2623
l���
re
(date'.
(signature/stamp) .(date)
AFUE
'Tank
WATER HEATER
EQUIPMENT DETAIL
/Rec
Rated
Stdby
Pilot
System Name
System Type
Eff
Input
Loss
R -Val
-----
Light
-----
-----------------------
AMERICAN APP
-----------
G52 -75T57 DomesticHW
---------
0.760
57000
-----
0.000
0.0
0
AMERICAN APP
G52-3OT33- DomesticHW
0.760
33000
0.000
0.0
0
J
SPECIAL FEATURES/REMARKS"
SHADES ON KIT,NOOK,BAR,LIV,FAM&DINE (EX TRANSOM &TOP OF #58)
'A Zonally Controlled -HVAC System which meets CEC criteria has been assumed
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building featureE and.performance
specifications needed to comply with Title 24, Parts 1 & E of the Califor
n'ia Code of Regulations,,and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
( Per Business & Professions Code)
SPARKS CONSTRUCTION
79-295 RANCHO LA QUINTA DR.
LA QUINTA, CA.
( 760 ) 771-1941 Lic #: 7
749
( ature) date)
ENFORCEMENT AGENCY
Name:
Title
Agency:
Telephone:
DOCUMENTATION AUTHOR
R.Krown, CEPE 90-4018
KROWN MECHANICAL DESIGN
P.O.BOX 1761
LA QUINTA, CA 9253
( 619) 773-2623
l���
re
(date'.
(signature/stamp) .(date)
MANDATORY MEASURES CHECKLIST (part 1 of 2 ) MF -:.R page 5 of 10
---------------------------------------------------------------------------
Project Name: PALACIO PLAN'l WITH -GUEST BEDROOM. ;Date: 3/4/1998
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the"compliance approach used. Items marked
with an asterisk (*) may be•superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features no -.ed shall'be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES Enforcement
o Sec. 150(a):Minimum R-19 ceiling insulation.
o .Sec. 150(b): Loose fill insulation manufacturers
labeled R -Value'.*
o Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
o Sec. 150(d): Minimum R-13 raised floor insulation in ffamed
floors; Minimum R-8 in concrete raised floors.
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.30, water vapor transmission rate no
greater than 2.0 perm/inch.
o'Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & farm.
o'Sec. 116-1i7: Fenestration Products, Ext Doors & Infil./Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products.have label w/certified U -Value
c. Exterior doors and windows weatherstr'ipped; all joints
and penetrations caulked and sealed.
o Sec. 150(8): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150(f): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards._
o Sec. 150(e):+Installation of Fireplaces, Decorative Gas.
Appliances and Gas Logs
1. Masonry and -factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control ,
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (pant 2 of 2) MF -_R page 6 of 10-
---------------------------------------------------------------------------
Project Name: PALACIO PLAN 1 WITH GUEST BEDROOM ;Date: 3/4/1998
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
---------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads�
and faucets certified by the Commission.
o Sec. 150(i): Setback thermostat on all applicable
heating systems.
o Sec. 150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (eg unfired storage tanks -Sr
backup solar hot water tanks) have insulation blankat
(R-12 or•greater) or combined interior/exterior insilation
.(R-16 or'greater).
2. First 5 feet- of pipes closest to water heater tank,-,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposed piping insulated in recirculation
sections of hot water system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between -heating source and indirect hot
water tank--.
o Sec. 150('m) Ducts and Fans * .
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and'1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers,.
o Sec. 114:Pool and Spa Heating Systems and'Equipment
1. System is certified with 78% thermal efficiency, or -off
switch, weatherproof,operating instructions,�no electric
resistance heating and no pilot light.
2. System is,installed with:
a. At least 36" pipe between filter and heater for future
solar heating.
b. Cover for outdoor, pools or outdoor spas.
3. Pool system has directional inlets,and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec., 150(k): Lighting - 40 lumens/watt .or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures.IC (insulation cover) appvoved.
COMPUTER METHOD SUMMARY C -2R page.7 of 10
Project Name: PALACIO PLAN 1 WITH GUEST BEDROOM ;Da_e.: 3/4/1998
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
POINT SYSTEM COMPLIANCE SUMMARY
Proposed Design Point Score
0
Points *BUILDING COMPLIES*
Budget Compliance Point Goal
0
Points
R-13
GENERAL INFORMATION -
Falcon
Foam
LIVING ZONE
Compliance Method:
COMPLY
24 version
4.11
- Climate Zone:
15
-
Yes
Conditioned Floor Area:
3465
sqft
LIVING ZONE
Building Type:
Single
Fam Det.
104
Building Front Orientation:
150 -deg
(SE)
'Yes-
Number of Dwelling Units:
1
;
Foam
Number of Stories:
1
DEN,
Wall
Floor Construction Type:
Slab on
Grade -
90'
Total Conditioned Volume:
37976
cuft
Falcon
Conditioned Footprint Area:
3465'sgft
&
DEN
Ground Floor Area:
3465
sqft
285
BUILDING.ZONE INFORMATION
Yes
R-13
+ 1"
Floor
# of
LIVING ZONE
Vent
Zone Name Area
Volume Units
Zone Type
TStat Type Hgt Area
_FAU/CU/COIL 1 1663
19956 0.48
Living
Liuing5tat 2 n/a
FAU/CU/COIL 2 1372
13720 0.40
Sleeping
SleepStat 2 n/a`
FAU/CU/COIL 3 430.1.
4300 0.12
.Sleeping
S1eepStat 2 n/a
OPAQUE SURFACES Act Solar
Type Area U -Val Azm Tilt Gains Form 3 Reference "Location/Comments
ZONE NAME = FAU/CU/COIL 1
Wall
186
0.061
150
90
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&
DEN
Door
48
0.387
150-
90.
Yes
Solid
Wood Door
LIVING ZONE
&
DEN
Wall.
104
0.061
195
90
'Yes-
R-13
+ 1"
Falcon
Foam
LIKING ZONE
&
DEN,
Wall
572
0.061
240
90'
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&
DEN
Wall
70
0.061
285
•90
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&"DEN
Wall
152
0.061
330
90
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&
DEN
Wall
40
0.061,
15
90
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&
DEN
Wall
52
0.061
60
90
Yes -.•
R-13
+ •1 "
Falcon
Foam
LIVING ZONE,
&
DEN
Wall
46
0.061
105
90
Yes
R-13
+ 1"
Falcon
Foam
LIVING ZONE
&
DEN
Wall
140
0.085
Int
90
No'
R-13
Partition
-(2x4.16)
LIVING ZONE
&
DEN
Roof
1663
0.029
150
0
Yes
Tile/Air
Sp./R-30/Gypbd
LIVING ZONE
&
DEN
ZONE
NAME
= FAU%CU/COIL 2
Wall
55
0.061
240
90
Yes
'R-13
+ '1"
Falcon
Foam
BECROOMS
Wall
121
0.061
330
90
Yes
R-13
+ 1"
Falcon
Foam
BECROOMS
'
Wall
620
0.061
60
90
Yes
R-13
+ 1"
Falcon
Foam
BECROOMS
Wall
25
0.061
105
90
Yes
R--13
+ 1"
Falcon
Foam
BECROOMS
Wall
217
0:085
Int
90
No
R-13
Partition
(2x4.16)
BEC -ROOMS
Door
23
0.387
Int
90--
No
Solid
Wood
Door
BECROOMS
Roof
1348
0.029
150
0
Yes
`Tile/Air
Sp./R-30/Gypbd
BEDROOMS
ZONE
NAME
= FAU/CU/COIL 3
Wall
142-0.061
150
90
Yes
R-13
+ 1"
Falcon
Foam
GUEST BEDROOM
Wall
105
0.061
240
90
Yes
R-13
+ 1"
Falcon
Foam
GUEST BEDROOM
Wall
5
0.061
285
90
Yes
R-13
+ 1"
Falcon
Foam
GUE:ST.BEDROOM
Wall
84
0.061 330
90
Yes,
R-13
+ 1" Falcon Foam
GUEST
BEDROOM
Door
24
0.387'330
90
Yes
Solid Wood Door,
GUEST
BEDROOM
` Wall
80
0.061 15
90
-Yes
R-13
+ 1" Falcon Foam .
GUEST
BEDROOM
' Wall
145
0.061 60
90
Yes
R-13
+ 1" Falcon Foam
GUEST
BEDROOM
Wall
70
0.061 105
,90
Yes
R-13
+ V'r Falcon Foam
GUEST
BEDROOM s•`
Wall
80
0.085 Int
90
No
R=13
Partition (2x4.16•)
GUEST
BEDROOM
Roof
430
0.029 ,150
0
Yes'
Tile/Airr, 5p'./R7-30/Gypbd
GUEST
y
BEDROOM
•
•
A
COMPUTER METHOD SUMMARY C -2R,- page 8 of 10
-----------------------------------------------------------------------.----
Project Name: PALACIO PLAN 1 WITH GUEST BEDROOM ;Date: 3/4/1998
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
PERIMETER LOSSES
Type Length
ZONE NAME = FAU/CU/COIL
Covered
139.5
Exposed
35.5
ZONE NAME =
FAU/CU/COIL
Covered
110.0
Exposed
8.5
ZONE NAME =
FAU/CU/COIL
Covered
93.5 -
,FENESTRATION SURFACES
F2
Factor
1
0.72
0'.90
2
0.72
0.90
3
0.72
Insulation
R -Val Depth, Location/Comments
----- ----- -----------------------
0.0 0 in LIVING ZONE & DEN
0.0 0 in LIVING ZONE & DEN
• •
# Type Area Frame Div U -Val
ZONE NAME =
FAU/CU/COIL
1
0.75
1
Wdw
Front
(SE)
6.0
Vinyl
No
2
Wdw
Front
(SE)
15.0
Vinyl
No
3
Wdw
Front
(SE)
17.5
Vinyl
No
4
Wdw
Front
(SE)
30.0
Vinyl
No
5
Wdw
Front
(SE)
18.0
Vinyl
Yes
6
Wdw
Front
(SE)
18.0
Vinyl
No
7, Wdw
Front
( S )
9.0
Vinyl
No,
8
Wdw
Front
( S )
15.0
Vinyl
No
9
Wdw
Front
( S )
6.7
None
No
10
Wdw
Left
(SW)
22.5
Vinyl
No
11
Wdw
Left
(SW)
18.0
Vinyl
No
12
Wdw
Left
(SW)
45.0
Vinyl
No
13
Wdw
Left
(SW)
18.0
Vinyl
No
14
Wdw
Left
(SW)
18.0
Vinyl
No
15
Wdw
Left
( SW)
15.0
Vinyl
No
16
Wdw
Left
(SW)
17.5
Vinyl
No
17
Wdw
Left
(SW)
8 .0
Vinyl
No
18
Wdw
Left
(SW)
20.0
Vinyl
No
19
Wdw
Back
(NW)
6.0
Vinyl
No
20
Wdw
Back
(NW)
15.0
Vinyl
No
21
Wdw
Back'
(NW)
30.0
Vinyl
No
22
Wdw
Back
(NW)
37-. 5
Vinyl
No
23
Wdw
Back
(NW)
10.0
Vinyl
No
24
Wdw
Back
(NW)
20.0
Vinyl
No
25
Wdw
Back
(NW)
35.0
Vinyl
No
26
Wdw
Back
(NW)
50.0
Vinyl
No
27
Wdw
Back
(NW)
25.0
Vinyl
No
28
Wdw
Back
( N )
21.0
Vinyl
No
29
Wdw
Back
( N )
9.0
Vinyl'
No'
30
Wdw.
Right
(NE)
24.0
Vinyl
No
31
Wdw
Right
(NE)
15.0
Vinyl
No
32
Wdw
Right
(E)
9.0
Vinyl
No
33
Wdw
Right
(E)
15.0
Vinyl
No
ZONE NAME =
FAU/CU/COIL
2
&
34
Wdw
Back
(NW)
30.0
Vinyl
No
35
Wdw
Back
(NW)
15.0
Vinyl
No
36
Wdw
Back
(NW,)
64 .0
Vinyl
No
37
Wdw
Right
(NE)
4.0
None
No
0 in BEDROOMS
0•in BEDROOMS
0 in GUEST BEDROOM
SC
Act Glass
Azm Tilt Only Locat-ion/Comments
0.55
150
90
0.75
LIVING
ZONE
&
DEN
0.55
150
90
0.75
LIVING
ZONE
&
DEN
0.60
150
90
0.75
LIVING
ZONE
&
DEN
0.57
150
90
0.75
LIVING
ZONE
&
DEN
0.57
150
90
0.75
LIVING
ZONE
&
DEN
0.57
150
90
0.75
LIVING
ZONE
&
DEN
0.57
195
90
0.75
LIVING
ZONE
&
DEN
0.60
195
90
.0.75
LIVING
ZONE
&
DEN
0.57
195
90
0.65
LIVING
ZONE
&
DEN
0.55
240
90
0.75
LIVING
ZONE
&
DEN
0.55
240
90
0.75
LIVING
ZONE
&
DEN
0.55
240
90
0.75
LIVING
ZONE
&
DEN
0.57
240
90
0.75
LIVING
ZONE
&
DEN
0.57
240
90
0.75
LIVING
ZONE
&
DEN
0.60
240
90
0.75
LIVING
ZONE
&DEN
0.60
240
90
0.75
LIVING
ZONE
&
DEN
0.57
240
90
0.75
LIVING
ZONE
&
DEN
0.55
240
90
0.75
LIVING
ZONE
&
DEN
0.55
330
90
0.75
LIVING
ZONE
&
DEN
0.55
330
90
0.75
LIVING
ZONE
&
DEN
0.57
330
90
0.75
LIVING
ZONE
&
DEN
0.55.330
90
0.75
LIVING
ZONE
&
DEN
0.57
330
90
0.75
LIVL'NG
ZONE
&
DEN
0.57
330
90
0.75
L I V LNG
ZONE
&
. DEN
0.57
330
90
0.75
LIVLNG
ZONE
&
DEN
0.57
330
90
0.75
LIVLNG
ZONE
&
DEN
0.60
330
90
0.75
LIVING
ZONE
&
DEN
0.57
15
90
0.75
LIVING
ZONE
&
DEN
0.60
15
90
0.75
LIVING
ZONE
&
DEN
0.55
60
90
0.75
LIVING
ZONE
&
DEN
0.55
60
90
`0.75
LIVING
ZONE
&
DEN
0.57
105
90
0.75
LIVING
ZONE
&
DEN
0.60
105
90
0.75
LIVING
ZONE
&
DEN
0.57
330
90
0.75
BEDROOMS
0.60
330
90
0.75
BEDROOMS
0.55
330
90
0.75
BEDROOMS
0.57
60
90.
0.65
BEDROOMS
N
. 38
wdw
Right (NE) 22 . b
Vinyl NO
U . b/
bu yU
U . /b
BtURUUMD
39
Wdw
Right (NE) 22.5
Vinyl ,No
0.60
60 90
0.75
BEDROOMS
40
Wdw
Right (NE) 6.0
Vinyl No
0.60
60 90
0.75
BEDROOMS
41
Sky
Front (SE) 24.0
Metal No
0:80
150 0
0.43
BEDROOMS
ZONE NAME = FAU/CU/COIL
3
42
Wdw
Front (SE) 8.0
None No
0.57
150 90
0.65
GUEST
BEDROOM
43
Wdw
Left (SW) 10.0
Vinyl'No
0.60
240 90
0.75
GUEST
BEDROOM '
44
Wdw
Left (SW),10.0
Vinyl No
0.60
240 90
0.75
GUEST
BEDROOM
45
Wdw
Back ( NW) 17.5
Vinyl No-'
-0.60
330 90
0.75
GUEST
BEDROOM
46
Wdw
Back (N) 30.0
Vinyl No
0.57
15 90
0.75
GUEST
BEDROOM
47
Wdw
Right (NE) 10.0
Vinyl No
0.60
60 90
0.75
GUEST
BEDROOM
INTERIOR & EXTERIOR'SHADING
#
--
Type
----
Interior Shade
-----------------------
Type
SC,
----
Exterior
------------------7----
Shade
Type
SC
----
1
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
2
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
3
Wdw
Std Drape
0.78
"Standard
Bug
Screen
0.87
4
Wdw
Opaque White
Rlr Shade
0.40
Standard -Bug
Screen
0.87
5
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
6
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
7
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
8
Wdw
Opaque,White
Rlr Shade
.0.40
Standard
Bug
Screen
0.87
9
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
10
Wdw
'Opaque White
Rlr Shade
0.40
Standard
Bug
Screen.
0.87
11
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
12
Wdw
Opaque White
Rlr Shade
.0.40
Standard
Bug
Screen
0.87
13
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
14
Wdw
Opaque White
Rlr, Shade
0.40
Standard
Bug
Screen
0.87
15
Wdw
Opaque White'Rlr'4Shade
0.40
Standard
Bug
Screen
0.87
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
016
17
Wdw
Std Drape
0.78
Standard
Bug
Screen
•' 0.87
-18
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
;19
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
20
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
21
Wdw
Opaque White
Rlr Shade
"0.40
Standard
Bug
Screen
0.87
22
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87''
23
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
24
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
25
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
26
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
27
Wdw
Opaque White
Rlr. Shade
0.40
Standard
Bug
Screen
0.87
28
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0:87
29
Wdw
Opaque White
Rlr Shade,
0.40
Standard
Bug
Screen
0.87 '
30
Wdw
Std Dr -ape
0.78
Standard,Bug
Screen
0.87
31
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
32
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0.87
33
Wdw
Opaque White
Rlr Shade
0.40
Standard
Bug
Screen
0:87
34
Wdw
Std Drape
0.78. -Standard
Bug
Screen
0.87
35
Wdw
Std Drape
0.78
Standard -Bug
Screen
0.87
36
Wdw
Std Drape
0.78
Standard
Bug
Screen
0:87
37
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
38
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
39
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
40
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
41
Sky
None :
1.00
None
11.00
42
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
43
Wdw
Std -Drape
0.78
Standard
Bug
Screen
0.87
44
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
45
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87
46
Wdw
Std Drape
0.78
Standard
Bug
Screen
0.87.
47
Wdw
Std Drape
0.78
,Standard
Bug
Screen
0.87
COMPUTER METHOD SUMMARY'
C -2R' page 9 of 10
Project
Name:
PALACIO PLAN 1 WITH
GUEST
BEDROOM ;Date: 3/4/1998
Documentation;'
KROWN MECHANICAL
DESIGN
;COMPLY 24 User 2366
OVERHANGS/SIDE
FINS
--Window--
---Overhang------
--=Left Fin--- ---Right Fin--
#
Type
Ht
Wd.
Len
Ht'-LExt
RExt
Dist Len Ht Dist Len Ht
1
Wdw
3.0
2.0
2.0
2.0
2.0
2.0
2
Wdw
7.5
2.0
2.0
6.0
2.0
2.0
3
Wdw
5.0
3.5
2.0
2.0
2.0
2.0
4
Wdw
5.0
6.0
2.0
6.0
2.0
2.0
5
Wdw
3.0
6.0
10.0
2.0
10.0
10.0
6
Wdw
3.0
6.0
2.0
2.0
2.0
2.0
`
7
Wdw
3.0
3.0
2.0
2.0
2.0
2.0
8
Wdw
5.0
3.0
2.0
6.0
2.0
2.0
9
Wdw
2.0
3.3
2.0
2.0
2.0
2.0
10
Wdw
5.0
4.5
2.6
2.0
2:0.
2.0
11
Wdw
3.0
3.0
2.0
2.0
2.0
2.0
12
Wdw
7.5
3.0
2.0•-
6.0
2.0
2.0
13
Wdw
3.0
6.0
2.0
2.0
2.0
2.0.
14
Wdw
3.0
3.0
2.0
2.0
2:0
2..0
15
Wdw
5.0
3.0
2.0
2.0
2.0
2.0
16
Wdw
5.0
3.5
6.0
6.0
6.0
6.0
17
Wdw
2.0
4.0
2.0
2.0
2.0
2.0
18
Wdw
7.5
2.7
2.0
2.0
2.0
2.0
19
Wdw
3.0
2.0
2 .0,
2.0
2.0
2.0
-20
Wdw
7.5
2.0
2.0
6.0
2.0
2.0
21
Wdw,
5.0
6.0
2,.0
' 2 .0
2.0
2.0
22
Wdw
7.5
2.5
2.0
2.0.
2.0
2.0 .
23
Wdw
2.5
4.0
2.0
'8.0
2.0
2.0
24
Wdw
5.0
4.0
2.0
2.0
2.0
.2.0
25
Wdw
4.0'
10.0
14.0
2.0
14.0 .14.0
26,-Wdw
5.0
10.0
14.0
6.0
14.0
14.0
28
Wdw
3.5
6.0
14.0
6.0
14.0
14.0
30
Wdw.
8.0
3.0
6.0
6.0
6:0
6..0
- 31
Wdw
7.5
2.0
2.0
6.0
2.0
2.0
32
Wdw
3.0
3.0
2.0
2.0
2.0
2.0
33
Wdw
5.0
3.0
� 2 .0
6.0
2.10
2.O
34
Wdw
5.0
3.0
8`.0
2.0
8.0 .
8.0
35
Wdw
2.5
3.0
8.0
8.0
8.0
8.0
36
Wdw
8.0
8.0
8.0
2.0
8.0
8.0
37
Wdw
2.0
2.0
2.0
2.0
2.0
2.0
38
Wdw
4.5
5.0
2.0
2.0
2.0
2.0
39
Wdw
5.0-
4.5
2.0
2.0
-2.0
2 .0
40
Wdw
4.0
1.5
.2.0
2.0
2.0
2.0
41
Wdw
8.0
2.0
2.0
2.0
2.0
2.0
42
'Wdw
5.0
2.0
2.0
2.0
2.0
2.0
43
Wdw
4.0
2.5
2.0
.2.0
2.0
2.0
44
Wdw
5.0
3.5
2.0
2.0
2.0
2.0
45
Wdw
5.0
6.0
2.=O
2.-0
2.0
2.0
46
Wdw
4.0
2.5
2.0
2.0
2.0
2.0
THERMAL
MASS
Area
Thick
Heat
Inside Location
Type
(sf)
(in)
Cap
Cond
Form
3 Reference R -Val . Comments
ZONE NAME = FAU/CU/COIL
1
Covered
Slabt
1253
3.50
28
0.98
n/a:
2
Exposed
Slab
410
3.50
28
0.98
n/a
0
Interior Mass 238 0.75 24, 0 67.. n/a 0
ZONE NAME = FAU/CU/COIL 2
Covered Slab 1251 3.50 28 0.98 n/a 2
Exposed Slab —121 3.50 '28 '0.98 �n/a 0'
ZONE NAME = FAU/CU/COIL 3 _
Covered Slab 430 3.50 28 0.98 n/a• 2
HVAC SYSTEMS Minimum Distr ib: Type,', Duct TStat
System Type Efficiency and Location, RVal Type Location/Comments
--
Furnace 0.801 AFUE Ducts in 4.2_SetBck,FAU/CU/COIL-1V r
'SpltAirCond12.000 SEER Ducts in Attic 4:2"SetBck
Furnace - 0.800 AFUE Ducts'in Attic 4.2 SetBck FAU/CU/COIL 2 ,
SpltAirCo'nd12.300 SEER Ducts in•Attic- 4.2 SetBck
Furnace 0.801 AFUE Ducts"in..Atti'c' 4.2 SetBck FAU/CU/COIL 3
SpltAirCond10.800 SEER Ducts in Attic 4.2•SetB6k,
:Water No' Tank Ext.
WATER HEATING SYSTEMS Heater in Enargy�,�Size Insul y..
System Name. Distribution Type Type Sys Factor - (gal) R -Val
____ __________ __- __ __-__-_ __ ___ __-- �-- --
AMERICAN APP G52 -75T57 Recirc-Time&Temp StorGas '1 0.51 _,75.0 12.0
AMERICAN APP G52-3OT33--Standard StorGas . ,1. 0.60 30.0' 0.0
AFUE
WATER HEATER`EQUIPMENT= DETAIL /Rec Rated Stdby. Tank Pilot
System Name .,System'•Type Eff Input Loss R -Val Light G
------------------------ --------- ---_ _____ ----- ---- _-_
AMERICAN'APP G52 -75T57 DomesticHW 0.760 57000 0.000 ;0.0 -0.
AMERICAN APP G52-3OT33- DomesticHW 0.760 33000 0.000 0.0 0'
SPECIAL FEATURES/REMARKS, , _•.
SHADES ON KIT,NOOK",BAR,LIV,FAM&DINE (EX TRANSOM &TOP OF #5$.)
A Zonally Controlled HVAC -System which meets CEC criteria has been"assumed
,� • 1 r
•
s
INSTALLATION CERTIFICATE CF -6R_ page 10 of 10
-
---------------------------------------------------------------------------
Project Name: PALACIO PLAN 1 WITH.GUEST BEDROOM ;Date: 3/4/1998
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
I, the undersigned,.verify that the equipment listed in the category above_
my -signature is the actual equipment installed and that the.equipment
meets or exceeds the requirements of the Appliance Efficieicy Standards.
In addition, I have verified that the equipment is equivalent to or more
efficient than the equipment specified on -.the Certificate of Compliance
submitted to demonstrate compliance with the Energy Efficiency Standards
for residential buildings. ,a
' a
HVAC SYSTEMS
Heat. Equip
CEC Certified.Manuf.
Actual Distrib Type
Duct Heat
Heat
System Type
Make &
Model Number
Eff. and Location
-------------------
R`Jal Load
---- ------
Output
------
-----------
Furnace
-----------------------
LENNOX
80MGF5--I00A-**
0.801 Ducts
in Attic
4.2 40745
82000
Furnace
LENNOX-80MGF4-75A-**
0.800 Ducts
in Attic
4.2 22574
61670
.:Furnace
LENNOX
80MGF2-45A-**
0.801 Ducts
in Attic
4.2 11569
36903
Cool. Equip
CEC Certified
Manuf.
Actual
Distrib
Type
Duct
System Type
Make &
Model Number
Efficiency
and Location
RVal
.SpltAirCond'LENNOX
12ACB60/C23-65
12.000 SEER'Ducts
in
Attic
4.2
SpltAirCond
LENNOX
12ACB42/C23-51
12.300 SEER
Ducts in
Attic
4.2
-„SpltAirCond
LENNOX
10AC24/C23-26
10.800 SEER
Ducts in
Attic
'4.2
Signature Date Name ,
Water No. Tank Ext.,,
WATER HEATING SYSTEMS Heater in Er_ergy Size Insul
CEC Cert. Make & Model,*Distribution Type Type Sys Factor (gal) R -Val
AMERICAN APP G52 -75T57 Recirc-Time&Temp StorGas 1 C.51 75.0 12.0
AMERICAN APP G52-3OT33- Standard, StorGas 1 C.60 30.0 0.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name' System Type Eff Input Loss R -Val Light
----------------------- ----------- ----• ----- --- -----; -----
AMERICAN APP G52 -75T57 DomesticHW 0.760 57000 0.000 0.w 0
AMERICAN APP G52-3OT33- DomesticHW 0.760 33000 0.000 0.0 0
FAUCETS & SHOWER HEADS:
All faucets and showerheads are listed in the Commissions Directory Of
Certified Faucets And Showerheads,.pursuant to Title 24, Fart 6,
Subchapter 2, Section 111. 1
Signature Date Name