Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-3454 (BLCK)
P.O. BOX 1504 78495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 06-00003454 Property Address: 52305 VIA CASTILE APN: 772-410-998-14 -32453 Application description: WALL/FENCE Property Zpninq: LOW DENSITY RESIDENTIAL Application valuation: 866 Tiht 4 4 Q" Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT -------------------------------------------------- LIC NSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I m licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busine Professionals Code, and my License is in full force and effect. License Class: C8 C27 C29 License No.: 656128 ate: y/?� ontractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I k n,exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and P ofessions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: ND LA QUINTA PARTNERS 375 N FRONT ST STE 200 COLUMBUS, OH 43215 Contractor: CALIFORNIA POOLS & SPAS P.O. BOX 1280 rOACHELLA, CA 92236 (760)398-9222 Lic. No.: 656128 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/26/06 D Q 0 SEP 2 7 2006 CITY OF LA QUINTA FINANCE DEPT. ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier SEABRIGHT "Policy Number BB1060510. I certify that, in the performance the work for which this permit is issued, I shall not employ any person in any manner so as to ecome subject to the workers' compensation laws of California, and agree that, if I should bec a subject to the workers' compensation provisions of Section �IZ00 of the Labor Code, I she with comply with those provisions. - f cant: WARNING: F URE TO SECURE WORKERS' NNIS PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENAAND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE T OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTERE,AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuanceAd, mit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state thinformation is correct. I agree to comply with all city and county ordinances and state laws relating tonstruction, and hereby authorize representatives of th�oupty to yiiter upon the above-mentioned pr}sp purposes. (Applicant or Application Number . . . . . 06-00003454 Permit . . . WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 23.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 866 Expiration Date . . 3/25/07 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 2.0000 HIND BLDG 501-2,000 8.00 ---------------------------------------------------------------------------- Special Notes and Comments 40 L.F. COMBO WALL, 3- RETAINING & 2 - GARDEN, CITY STANDARD Fee summary Charged -------- - ---------- Paid Credited ---------- ---------- Due ----------------- Permit Fee Total 23.00 .00 .00 23.00 Plan Check Total .00 .00 .00 .00 Grand Total 23.00 .00 .00 23.00 LQPERAIIT Total Permit Bin # City of. La Quinta Building u Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quints, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �� a Project Address:s�� V A. P. Number: Owner's Name:^\ Address: Legal Description: City, ST, Zip: Contractor Telephone:own Project Description: Address: �© Z City, ST, Zip - Telephone: %C!� . � 3ql% State Lie. # : City Lic. Arch., Engr., Designer: �� P—ETA IA ' .vC 67A (2 Address: •. City, ST, Zip: Telephone: Construction Type: Occupancy: P cY: . State Lie. #: Project type (circle one): Add'a Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: . Telephone # of Contact Person: giao— (-1(-12 S' Estimated Value of Projeo:. l :� APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal ' Plan Sets Req'd Reed TRACING Plan•Check submitted PERMIT FEES Item Amount Structural Calcs. Reviewed; ready for corrections Plan CheckDeposit Tress Caks. Called Contact Person Plan Cheek Balance Energy Calcs. . Plans pickeup d Construction Flood plain plan Plans resubmitted Mechanical Grading plan' 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ILO:A. Approval Plans resubmitted Grading IN HOUSE:-. '" Review, ready for correctionsrusue Developer hnpact Fee Planning Approval Pub. Wks. Appr . Called Contact Person Date of permit issue A.I.P.P. School Fees Total Permit CITY OF LA QUINTA BUILDING AND SAFETY DEPARTMENT RETAINING WALL STANDARD RETAINING WALL SPECIFICATIONS ALL WALLS SHALL BE CONSTRUCTED OF THE HIGHEST QUALITY. TABLE NO.24-A—MORTAR PROPO iTMS FOR UNIT MASONRY WORKMANSHIP IN ACCORDANCE WITH THE 1991 U.B.C., AND THE FOLLOWING SPECIFICATIONS: 1. CONCRETE - T c=2000 PSI AT 28 DAYS PER ASIM C150 2. MASONRY - Y m=.1500 PSI GRADE IN PER ASTM C150 3. GROUT 2000 PSI AT 28 DAYS PER U.B.C. TABLE 24-8 4. MORTAR 2000 PSI AT 28 DAYS PER U.B.C. TABLE 24-A AMB ASTM C2.70 5. REINFORCING - DEFORMED BARS CONFORMING TO ASTM, A615 GRADE 40. STEEL LAPS SHALL BE 40 BAR DIAMETERS OR MORE. BEND HORIZONTAL BARS AROUND CORNERS A MINIMUM .OF 24". VERTICAL STEEL SHALL BE HELD IN PLACE BY WIRE TIES AT THE TOP AND BOTTOM OF THE BARS BUT NOT EXCEEDING 8 FT. IN SPACING PRIOR TO SPACING PRIOR TO GROUTING. STEEL PLACEMENT IS CRITICAL AT THE BASE OF WALLS AND AT CHANGES IN BLOCK SIZE. ADHERE STRICTLY TO THE DIMENSIONS SHOWN ON THE PLANS. ,WbnpLwk mwwo is Mud k lien ofpoTW.dat ew.hydrrd lime mp,Ntd mybc edacd. but act in OWOCOW bt6aft6c voM,med«aw. 6. ALL FOOTING TO BE POURED ON UNDISTURBED NATURAL GROUND - �htua•y aNMn ennforrmD�a Werap ranWs•f u.e.c. StMdMd No Slts. OR ON COMPACTED FILL WITH A MINIMUM DENSITY OF 90% vMaMr amaN moformiO�gdN �RimrNDM of U.B.C. Steodud Nes 2H9. RELATIVE COMPACTION. 7. DRAINAGE SHALL BE ACCOMPLISHED PY PLACING A 3" DIAMETER PERFORATED ABS OR PVC DRAIN LINE BEHIND THE WALL AT THE TOP OF THE FOOTING AND COVER WITH 1 CUBIC FOOT PER LINEAL FOOT OF 1l2" PEA GRAVEL, AT LEAST B" OVER THE TOP OF THE PIPE. EXIT THE DRAIN LINE OUTSIDE THE WALL AT A LOCATION WHERE THE DISCHARGE OF WATER WILL NOT BE OBSTRUCTED AND AS APPROVED BY THE BUILDING OFFICIAL. MAINTAIN AT LEAST i I% GRADE. 8. PROVIDE VERTICAL EXPANSION JOINTS PER DETAIL HEREON SPACE BETWEEN 60 FT. AND 200 FT. APART. PLACE EXPANSION JOINT AT l I 1�rG+ FOOTING STEPS UNLESS NO STEP IS PRESENT. � 9. GROUT LIFT SHALL NOT EXCEED 6 FT. WHEN GROUTING IS (Jr -4- PERFORMED IN MORE THAN ONE LIFT, STOP THE INTERMEDIATE ��11 GROUT LIFT 1-1'2" BELOW THE TOP OF THE BLOCK TO PROVIDE A KEY FOR THE NEXT LIFT. t 10.- BACKFILLING SHALL NOT. OCCUR'UNTIL AT LEAST 14 DAYS AFTER 1 GROUTING IS COMPLETE. * # I v�Ghjt� i1�fAY'' f^I�•• ����3F�� 11. GROUT ALL CELLS SOLID_ i j � ! i i ! � jj - - - I _ • - ! . I �1,A 11 fA�''r0 t Fay i . L Ica f 1 �GTIi i r�.la --- I CITY OF - . BUILD IN(U OL SAFETY 01 PT. - - - APPROVED FOR CONSTRUCTION •UO'offly !lT VOLUME rcENFl1TtIMXh w1EUUW AoonE n PORn AMO 1Ro"wo MEASURED. CEMENTM nEwEO Yl1lOIMT C[MEMTT Yd11M fXYaT LME on LOVE IN AOAM11 LOOK M E M M E N OMAR TV" CEMENT, NTT" CoNornow camE-lime : M S 1 . — — — — — — over.1.b,h N 1 — — — — — — over -h to Iw Nmkuthm24. O 1 — — — — — — aver I,r. q wd not mwe due - 2,h J Rima the Tom of the wpm to M.rtu Dt M 1— — — — _ 1 — vohumm of M — — — — 1 — — — amaMaioof S ,h — — _ — _ 1 — 5 N 1 MMowy acmes M . 1.— S O 1 THE PLANS. ,WbnpLwk mwwo is Mud k lien ofpoTW.dat ew.hydrrd lime mp,Ntd mybc edacd. but act in OWOCOW bt6aft6c voM,med«aw. 6. ALL FOOTING TO BE POURED ON UNDISTURBED NATURAL GROUND - �htua•y aNMn ennforrmD�a Werap ranWs•f u.e.c. StMdMd No Slts. OR ON COMPACTED FILL WITH A MINIMUM DENSITY OF 90% vMaMr amaN moformiO�gdN �RimrNDM of U.B.C. Steodud Nes 2H9. RELATIVE COMPACTION. 7. DRAINAGE SHALL BE ACCOMPLISHED PY PLACING A 3" DIAMETER PERFORATED ABS OR PVC DRAIN LINE BEHIND THE WALL AT THE TOP OF THE FOOTING AND COVER WITH 1 CUBIC FOOT PER LINEAL FOOT OF 1l2" PEA GRAVEL, AT LEAST B" OVER THE TOP OF THE PIPE. EXIT THE DRAIN LINE OUTSIDE THE WALL AT A LOCATION WHERE THE DISCHARGE OF WATER WILL NOT BE OBSTRUCTED AND AS APPROVED BY THE BUILDING OFFICIAL. MAINTAIN AT LEAST i I% GRADE. 8. PROVIDE VERTICAL EXPANSION JOINTS PER DETAIL HEREON SPACE BETWEEN 60 FT. AND 200 FT. APART. PLACE EXPANSION JOINT AT l I 1�rG+ FOOTING STEPS UNLESS NO STEP IS PRESENT. � 9. GROUT LIFT SHALL NOT EXCEED 6 FT. WHEN GROUTING IS (Jr -4- PERFORMED IN MORE THAN ONE LIFT, STOP THE INTERMEDIATE ��11 GROUT LIFT 1-1'2" BELOW THE TOP OF THE BLOCK TO PROVIDE A KEY FOR THE NEXT LIFT. t 10.- BACKFILLING SHALL NOT. OCCUR'UNTIL AT LEAST 14 DAYS AFTER 1 GROUTING IS COMPLETE. * # I v�Ghjt� i1�fAY'' f^I�•• ����3F�� 11. GROUT ALL CELLS SOLID_ i j � ! i i ! � jj - - - I _ • - ! . I �1,A 11 fA�''r0 t Fay i . L Ica f 1 �GTIi i r�.la --- I CITY OF - . BUILD IN(U OL SAFETY 01 PT. - - - APPROVED FOR CONSTRUCTION