08-0354 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
c&ht 4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Application Number:
08-00000354
Owner:
Property Address:
52575 VIA CASTILE
ND LA QUINTA PARTNERS
APN:
772-410-998-26 -32453 -
375 N FRONT ST STE 200
Application description:
ADDITION - RESIDENTIAL
COLUMBUS, OH 43215
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
150000
D
01
Contractor:
Applican
Architect or Engineer:
A & M CONSTRUCTION
P.O. BOX 366
j0
1 i
LA QUINTA, CA 92247
(760)564-4832
Lic. No.: 746198
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am license under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Profes.' nals Code, and my License is in full force and effect.
License Class: B C10 License Nq,;, 746198
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure,. prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Date: 4/22/08
�Qu�NTa.
C1N 0 u rE Dpi.
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensatiori, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 044-0028137-07
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I shou become subject to the workers' compensation provisions of Section
^� 3700 of the Labor Cc I shall fofthwith comply with those provisions.
Date: C� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application an state that the above information is correct. I agree to comply with all
city and county ordinances and state law, relating to building construction, and hereby authorize representatives
of this county to enter upon the above- a tinned propertn purposes.
�j O
Dated �� Signature IAppli nt or Agent):
Application Number
Permit . .
Additional desc .
Permit Fee . . .
Issue Date . . .
Expiration Date .
. . . . 08-00000354
BUILDING PERMIT
814.50 Plan Check Fee . . 529.43
Valuation . . . . 150000
10/19/08
Qty Unit Charge Per Extension
BASE FEE 639.50
50.00 3,5000 THOTT RT,nr, 1 nn; nni -inn, nnn 175.00
----------------------------------------------------------------------------
Permit . . . ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . . . 23.65 Plan Check Fee 5.91
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/19/08
Qty Unit Charge Per Extension
BASE FEE 15.00
247.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 8.65
----------------------------------------------------------------------------
Permit MECHANICAL
Additional desc . .
Permit Fee . . . . 24.00
Issue Date
Expiration Date . . 10/19/08
Plan Check Fee . . 6.00
Valuation . . . . 0
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
1.00
9.0000
EA
MECH APPL
REP/ALT/ADD
9.00
----------------------------------------------------------------------------
Special Notes
and Comments
ADD STAIRWAY AND LOFT
ABOVE
EXISTING
GREAT ROOM 247
SQ. FT.
WHILE
UNDER
CONSTRUCTION.
----------------------------------------------------------------------------
Other Fees .
. . . .
. . .
. ENERGY
REVIEW FEE
52.94
STRONG
MOTION (SMI) -'RES
15.00
Fee summary Charged
Permit Fee Total 862.15
Plan Check Total 541.34
Other Fee Total 67.94
Grand Total 1471.43
LQPEn1IT
Paid Credited Due
.00 .00 862.15
.00 .00 541.34
.00 .00 67.94
.00 .00 1471.43
Bin 74! 44 €
'
City of La Quinta
Building 8z Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
36-q
Project Address: S2, v"A, Owner's Name:
Aj&;� ruaL T -)1911-
A. P. Number:127) 6 —67J6 Address:
Legal Description: City, ST, Zip:
Contractor: AN Telephone:
Address: 7 rmss i-ZL Project Description: r
City, ST, Zip: L-11-(� V (; kh., l.f�•- ""J' `7;n'
ALI. P1
Telephone: a ,L
'7
State Lic. # :
City Lic. #:
Arch., Engr., Designer:
Address: ? ,� 6eJ 8 20
City, ST, Zip:
Telephone: ( -7 _L�'�'� Construction Type: Occupancy:
State Lic. #: 5-L Project type (circle one): New Add lte Repair Demo
Name of Contact Person: �S Sq. Ft.: # Stories: Z, it Units:
Telephone # of Contact Person: �f d Estimated Value of Proje s �j d
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING . PERMIT FEES
Plan Sets
Plan Check submitted
Amount
Structural Calcs.
Reviewed, ready f corrections Plan Check Deposit
Truss Calcs.
Called Contact Pers — / Plan Check Ealance
Energy Cales.
Plans picked up 4
Construction
Flood plain plan
Plans resubmitted
?� Mechanical
Grading plan
2" Review, ready for correction -ssue � 7 2, Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:
3' Review, ready for corrections/issue Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue '5(v Dal
is r
School Fees
Total Permit Fees
3(3109' N(`5 RK- 3� e0emz VU.A57
414 Pis pPPRnt:-4616r
�° Fc 7// 22- fP U Rey To t�66 v6
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMIIND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: La Quint# Partners
Owner's Name: La Quinta Partners
Project Address: 52-575 Via Castile, La Quinta, CA
Project Description: Stairway and Loft addition
APN: 772410-998-26
Date: May 7, 2008
Phone No. (760)
Tract #: Lot #'s:
Type of Development: Residential XX Commercial Industrial
Total Square Feet of Building Area: 247 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the pbove information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to signs behalf of the owner/developer.
/ •
Dated: 05/07/08
Signature:
************************************1***********************************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project
65995 Approval
247 sq. ft.
$ 0.00
$ 0.00
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Support Services
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note: Pursuant to AB -181, any mobilehomes being replaced
or relocated within the same school district are exempt from
developer fees. Any additions of 500 sq. ft. or less is also
Ix me pt from developer fees. (Unless additions are on a�
structure that is under construction.)
Certificate issued by: Leticia C. Torres, Facilities Analyst Signature:
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
M V:c/mdocs/dei feesicertificate of compliance form tablesTO l ISF.doc '1/16/03 T
I TITLE 24 REPORT I
Title 24 Report
PRESCRIPTIVE PACKAGE D ALTERNATIVE
� C/N of � Qv�nrr
BUILDING & SAFN A
E'T.
FOR oROV
NSTRU p 24
DA
08� idham Fa ily Trust Residence
75 Via Castile
uinta, CA 92253
Resort for:
La
Project Designer:
STEPHEN NIETO
SOUTH WEST CONCEPTS
78-115 CALLE ESTADO, SUITE 201
LA QUINTA, CA 92253
Report Prepared By:
STEPHEN NIETO
Date:
4/2/2008
APR 03 2008
Alternative Component Package Method: (check one) C D ./ D (Alternative)
• Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CF -IR page 3)
• For Package D Alternative see Appendix B Table 151-C Footnotes 8-14 in the Residential Compliance Manual (RCM)
GENERAL INFORMATION
Total Conditioned Floor Area (CFA) 3,325 ft z
Average Ceiling Height: 9 ft
Check Applicable Boxes
Building Type: (check one or more) ./ Single Family Multifamily ./ Addition ./ Alteration
(If adding fenestration fill out WS -4R, Fenestration Maximum Allowed Area Worksheet and see Section 8.3.2
for Additions and 8.3.3 for Alterations in the RCM.)
• Maximum Allowed Total Fenestration Area 10.4 ft2(from WS -4R)
• Maximum Allowed West Facing Fenestration Area NONE ADDED ft2(from WS -4R)
• Number of Stories: 2 Number of Dwelling Units: 1 la
• Floor Construction Type: Raised Floor (circle one or both)as
• Front Orientation: 270 North / South / West: All Orientations (input front orientation in degrees
from True North and circle one).
RADIANT BARRIER (check box if required in climate zones 2 4 8-15)
OPAQUE SURFACES INCLUDING OPAQUE DOORS
1) See Joint Appendix IV in Section IV.2, N.3 and IVA, which is the basis for the U -factor criterion. U -factors can not exceed
prescriptive value to show equivalence to R -values.
2) This column is for the Inspector to verify installation of roof radiant barrier.
Residential Compliance Forms December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 1 of 5) CF -1R
Project Title Date Building Permit #
Stidham Family Trust Residence April 2, 2008
Project Address
52575 Via Castile
La Quinta, CA 92253 Plan Check /Date
Documentation Author Telephone
Stephen Nieto (760) 564-4707 Field Check /Date
Compliance Method (Prescriptive) Climate Zone
Prescriptive D (Alternative) 15 Enforcement Agency
Component
Type (Wall,
Roof, Floor,
Slab Edge,
Doors)
Frame
Type
(Wood or
Metal
Cavity
Insulation
R -Value
Continuous
Insulation
R -Value
Assembly U -
factor (for wood,
metal frame and
mass
assemblies)'
Joint
Appendix
IV
Reference
Roof Radiant
Barrier
Installed
Yes or No
Location
Comments
(attic, garage,
typical, etc.
Roof
Wood
R-38
R-0.0
Use Onl
Alternative Component Package Method: (check one) C D ./ D (Alternative)
• Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CF -IR page 3)
• For Package D Alternative see Appendix B Table 151-C Footnotes 8-14 in the Residential Compliance Manual (RCM)
GENERAL INFORMATION
Total Conditioned Floor Area (CFA) 3,325 ft z
Average Ceiling Height: 9 ft
Check Applicable Boxes
Building Type: (check one or more) ./ Single Family Multifamily ./ Addition ./ Alteration
(If adding fenestration fill out WS -4R, Fenestration Maximum Allowed Area Worksheet and see Section 8.3.2
for Additions and 8.3.3 for Alterations in the RCM.)
• Maximum Allowed Total Fenestration Area 10.4 ft2(from WS -4R)
• Maximum Allowed West Facing Fenestration Area NONE ADDED ft2(from WS -4R)
• Number of Stories: 2 Number of Dwelling Units: 1 la
• Floor Construction Type: Raised Floor (circle one or both)as
• Front Orientation: 270 North / South / West: All Orientations (input front orientation in degrees
from True North and circle one).
RADIANT BARRIER (check box if required in climate zones 2 4 8-15)
OPAQUE SURFACES INCLUDING OPAQUE DOORS
1) See Joint Appendix IV in Section IV.2, N.3 and IVA, which is the basis for the U -factor criterion. U -factors can not exceed
prescriptive value to show equivalence to R -values.
2) This column is for the Inspector to verify installation of roof radiant barrier.
Residential Compliance Forms December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 1 of 5) CF -1R
Project Title Date Building Permit #
Stidham Family Trust Residence April 2, 2008
Project Address
52575 Via Castile
La Quinta, CA 92253 Plan Check /Date
Documentation Author Telephone
Stephen Nieto (760) 564-4707 Field Check /Date
Compliance Method (Prescriptive) Climate Zone
Prescriptive D (Alternative) 15 Enforcement Agency
Component
Type (Wall,
Roof, Floor,
Slab Edge,
Doors)
Frame
Type
(Wood or
Metal
Cavity
Insulation
R -Value
Continuous
Insulation
R -Value
Assembly U -
factor (for wood,
metal frame and
mass
assemblies)'
Joint
Appendix
IV
Reference
Roof Radiant
Barrier
Installed
Yes or No
Location
Comments
(attic, garage,
typical, etc.
Roof
Wood
R-38
R-0.0
0.025
Table IV.1
Yes
Addition
Wall
Wood
R-21
R-0.0
0.069
Table IV.9
Addition
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page.2 of 5) CF -1R
Project Title
Date
Stidham Family Trust Residence
April 2, 2008
FENESTRATION PRODUCTS - U -FACTOR AND SHGC
2 FENESTRATION MAXIMUM ALLOWED AREA WORKSHEET WS -4R - must be included for New
Construction, Additions and Alterations.
Fenestration
#/Type/Pos.
(Front, Left,
Rear, Right,N,
Skylight
Orien-
tation,
S E W'
Area
(ft2
U -factor
U-factorz Source'
SHGC°
SHGC
Sources
Exterior
Shading/Overhangs6''
./box if WS -3R is
included
Front
North
5.2
0.39 NFRC
0.37
NFRC
❑
Left
East
5.2
0.39 NFRC
0.37
NFRC
❑
1) Skylights are now included in West -facing fenestration area if the skylights are tilted to the west or tilted in any direction
when the pitch is less than 1:12. See §151(f)3C and in Section 3.2.3 of the Residential Manual
2) Enter values in this column are either NFRC Rated value or from Standards default Table 116A
3) Indicate source either from NFRC or Table 116A
4) Enter values in this column from NFRC or from Standards Default Table 116B or adjusted SH13C from WS -3R
5) Indicate source either from NFRC or Table 116B.
6) Shading Devices are defined in Table 3-3 in the Residential Manual and see WS -3R to calculate Exterior Shading
devices.
7) See Section 3.2.4 in the Residential Manual.
HVAC SYSTEMS
Heating Equipment
Type and Capacity
(fumace, heat pump, boiler, etc.)
Minimum
Efficiency
(AFUE or HSPF
Distribution
Type and Location Duct or Piping Thermostat Configuration
ducts attic, etc. R -Value Type (split or package)
EXISTING
Cooling Equipment
Type and Capacity Minimum
(A/C, heat pump, evap. Efficiency
cooling) SEER or EER
Distribution Type
and Location Duct or Piping Thermostat Configuration
ducts, attics, etc.) R -Value Type (split orpackage)
EXISTING
Residential Compliance Forms
December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 3 of 5) CF -1R
Project Title
Date
Stidham Family Trust Residence
Apri 2, 2008
SEALED DUCTS and TXVs (or Alternative Measures)
A signed CF -4R Form must be provided to the building department for each home for which the following. are required.
77
❑
Sealed Ducts all climate zones Installer testing and certification and HERS rater field veri=ication required.)
❑
TXVs, readily accessible (climate zones 2 and 8-15 only)
Tank
Capacity
(gallons)
Installer testing and certification and HERS Rater field verification required.)
❑
Refrigerant Charge (climate zones 2 and 8-15 only) (Installer testing and certification and HERS Rater field
TANKLESS
verification required.)
OR
❑ Alternative to Sealed Ducts and Refrigerant Charge /TXVs (See Package D Alternative Package Features for
Project Climate Zone in the RM Appendix B Table 151-C, Footnotes 7-14.
OR
❑ No ducts installed.
❑ New ducts from existing space conditioning equipment, not exceeding 40 ft. in length.
For additions and alterations, duct systems that are not documented to have been previously
❑ sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the
Residential ACM Manual. Duct systems with more than 40 linear feet in unconditioned
spaces shall meet the requirements of Section 150(m) and duct insulation requirements of Pwka e D.
WAIEK HEA 111NU JYNYUMS
❑
Check box if system meets criteria of a "Standard" system. Standard system is one gas-fired.water heater per
Number
in System
dwelling unit. If the water heater is a storage type, 50 gallons is the maximum capacity and recirculation system is
Tank
Capacity
(gallons)
not allowed.
lI
Check box when using Preapproved Alternative Water Heating table, Table 5-4 in Chapter ` in the Residential
TANKLESS
Manual. No water heating calculations are required, and the system complies automatically.
ONE
Check box if system does not meet criteria of "Standard" system, and does not comply with :he Preapproved
❑
Alternative Water Heating table. In this case, the Performance Method must be used and must be included in the
submittal.
❑
I Check box to verify that a time control is required for a recirculating system pump for a system serving multiple units
Systems serving single dwelling units (See RM Table 5-4, Alternative Water Heatine Svstems for recirculation reouirements.)
Water Heater
Type/Fuel Type
Distribution
Type
Number
in System
Rated
Input'
(kW or
Btu/hr)
Tank
Capacity
(gallons)
Energy
Factor' or
Thermal
Efficient
Standby'
Loss (%)
Tank
External
Insulation
R -Value
TANKLESS
ONE
175,000
0
87%
System serving multiple dwelline units (See Residential Manual Section 5.3.3)
Water Heater
Type
Distribution
Type
Number
in System
Rated
Input'
(kW or
Btu/hr)
Tank
Capacity
(gallons)
Energy
Factor' or
Therm)
Efficient
Standby'
Loss %)
Tank
External
Insulation
R -Value
1) For small gas storage water heaters (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance, and
heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000
Btu/hr), list Rated Input, Recovery Efficiency, Thermal Efficiency and Standby Loss. For instantaneous gas water
heaters, list Rated Input and Thermal Efficiencies.
Pipe Insulation (kitchen lines > 3/4 inches) All hot water pipes from the heating source to th= kitchen fixtures
that are 3/a inches or greater in diameter shall be thermally insulated as specified by Section 150 0) 2 A or 150 0) 2 B.
Residential Compliance Forms
December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 4 of 5) CF -1R
Project Title
Date
April 2, 2008
Stidham Family Trust Residence
SPECIAL FEATURES REQUIRING BUILDING OFFICIAL or HERS RATER VERIFICATION
Indicate which special features are part of this project. The list below only represents special features relevant to the
prescriptive method. (Check Applicable boxes)
Category
Building Official
Verification of
Special Features 11
HERS Rater
Verification
HERS Rater
Diagnostic
Testing
Measure
Ducts
❑
Y
100% of ducts in crawlspace / basement
❑
Y
Buried ducts
❑
Y
Diagnostic supply duct location, surface area, and R -value
❑
Y
Duct increased R -value
❑
Y
Duct leakage
❑
Y
Ducts in attic with radiant barriers
❑
Y
Less than 12 ft. of duct outside conditioned space
❑
Y
Non-standard duct location
❑
Y
Supply registers within two ft. of floor
Envelope
❑
Y
Air retarding wrap
❑
Y
Cool roof
❑
Y
Exterior shades
❑
Y
High thermal mass
❑
Y
Inter -zone ventilation
❑
Y
Metal framed walls
❑
Y
Non -default vent heights
❑
Y
Quality insulation installation
❑
Y
Radiant barrier
❑
Y
Reduced infiltration (blower door). May also require mechanical ventilation.
❑
Y
Solar gain targeting (for sunspaces)
❑
Y
Sunspace with interzone surfaces
❑
Y
I Vent area greater than 10%
HVAC E ui ment
❑
Y
Adequate air flow
❑
Y
Air conditioner size
❑
Y
Air handler fan power
❑
Y
High EER
❑
Y
Hydronic heating systems
❑
Y
Mechanical ventilation
❑
Y
Refrigerant charge
❑
Y
Thermostatic expansion valve (TXV)
❑
Y
Zonal control
Water Heater
❑
Y
Combined hydronic
❑
Y
High EF for existing water heaters
❑
Y
Non-NAECA water heater
❑
Y
Non-standard water heaters (wh/unit)
❑
Y
Water heater distribution credits
Residential Compliance Forms
December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
(Page 5 of 5) CF -1R
Project Title
Stidham Family Trust Residence
Date
April 2, 2008
Special Remarks
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title
24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall design responsibility. The
undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge
and TX -Vs, insulation installation quality, and building envelope sealing require installer testing and
certification and field verification by an approved HERS rater.
Designer or Owner (per Business and Professions Code) Documentation Author
Name:
Stephen Nieto
Name:
Stephen Nieto
Title/Firm:
South West Concepts
Title/Firm:
South West Concepts
Address:
78-115 Calle Estado, Suite 201
Address:
78-115 Calle Estado, Suite 201
La Quinta, CA 92253
La Quinta, CA 92253
Telephone:
(760) 564-4707
Telephone:
(760) 564-4707
License #:
523837 G.C.
License #: (if applicable)
(sign re)
(date)
(signature)
(dat )
Enforcement Agency
Name:
Title
Agency:
Telephone:
Residential Compliance Forms
Comments:
December 2005
MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 1 of 2) MF -1R
Project Title
Stidham Family Trust Residence
Date
April 2, 2008
mote: Low-rise restaennai Duuamgs suDject to the Ntanaaras must contain these measures regardless of the compliance approach used
More stringent compliance requirements from the Certificate of Compliance supersede the items marked wit:t an asterisk (*) below.
When this checklist is incorporated into the permit documents, the features noted shall be considered by all Farties as minimum
component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this
checklist only.
Instructions: Check or initial applicable boxes when or check NA if not applicable and included with the permit application documentation.
DESCRIPTION
NA
Designer
Enforce -
ment
Building Envelope Measures:
* § 150(a): Minimum R-19 in wood frame ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑
§ 150(6): Loose fill insulation manufacturer's labeled R -Value:
®
❑
❑
• §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply
exterior mass walls)
El11to
* §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
2
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closeable metal or glass door covering the entire opening of the firebox
0
❑
❑
b. outside air intake with damper and control, flue damper and control
2
❑
❑
2. No continuous burning gas pilot lights allowed.
2
❑
❑
§150(0: Air retarding wrap installed to comply with § 151 meets requirements specified in the ACM Residential Manual.
2
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
2
❑
❑
§ 150(1) : Slab edge insulation - water absorption rate for the insulation material alone without facings no greater than
water vapor performance rate no greater than 2.0 perm/inch.
El
110.3%
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R
Form:
El
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑
2. Fenestration products (except field -fabricated) have label with certified U -factor, certifies Solar Heat Gain
SHGC and infiltration certification.
❑
El
3. Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed.
2
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
2
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE. SMACNA or ACCA.
21
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
]
❑
§ 1500): Water system pipe and tank insulation and cooling systems like insulation.
❑
❑
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
an installed thermal resistance of R-12 or greater.
10
El
El
2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or
internal insulation and indicated on the exterior of the tank showingthe R -value.
Ga
El
11R-16
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length
recirculatingsections of hot water pipes shall be insulated to Table 150B.
El
12
Elof
2. Cooling System piping (suction, chilled water, or brine lines), piping insulated between heating source and
hot water tank shall be insulated to Table 150-B and Equation 150-A.
El
11indirect
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
121
❑
❑
Residential Compliance Forms
December 2005
MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 2 of 2) MF -1R
DESCRIPTION
Enforce -
NA
Designer
ment
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
d
✓
./
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
❑
Cl
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in
Cl
E]conditioned
space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
* § 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirement of the CMC Sections 601, 602, 603, 604, 605
and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-0.2 or enclosed
entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
❑
[0
❑
requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings ter than 1/4 inch, the combination of mastic and either mesh or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
El
10
❑
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
El
12
11unless
such tae is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft of automatic dampers.
10
❑
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
12
El
Eldampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
❑
❑
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑
❑
❑
§114: Pool and Spa Heating Systems and Equipment.
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑
Elheater,
weatherproof operating instuctions, no electric resistance heatingand no pilot light.
2. System is installed with:
a. at least 36" of pipe between filter and heater for future solar heating. ❑ ❑
b. cover for outdoor pools or outdoor spas. ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters, or household cooking appliances have no continuously
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ ❑
§ 118(i): Cool Roof material meets specified criteria ❑ ❑
Residential Lighting Measures:
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as
outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater
❑
❑
are electronic and have an output frequency no less than 20 kHz
§150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑
El150-C,
luminaire has facto installed HID ballast
§150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as
determined in § 130 (c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy
E]
Elluminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy
luminaires,
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms & utility rooms shall be high efficacy
luminaires. OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not tum on
❑
❑
automatically or have an always ono tion.
§ 150(k)1: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets less than 7082): OR are controlled by a dimmer switch OR are
El
10
Elcontrolled
by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always
ono tion.
§ I50(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑
❑
certified airtight to ASTM E283 and labeled as air tight AT to less than 2.0 CFM at 75 Pascals.
§150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not including lighting around swimming pools / water features or other
�
❑
❑
Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section
119d:
§ I50(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147.
htin for parkinggarages for 8 or more vehicles shall have Ii htin that com lies with Sec. 130, 131 and 146.
❑
C1Li
§ I50(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or
more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
El
El
Residential Compliance Forms
December 2005
Residential Kitchen Lighting Worksheet WS -5R
Project Title
Stidham Family Trust Residence
Date
I April 2, 2008
At least 50% of the total rated wattage of permanently installed luminaires in the kitchen must be in luminaires that are high
efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
Luminaire Type High Efficacy? Watts x Quantity = High Efficacy Watts or Other Watts
EXISTING Yes ❑ No ❑ x = or
Yes ❑ No ❑ x = or
Yes ❑ No ❑ x = or
Yes ❑ No ❑ x = or
Yes ❑ No ❑ x = or
Total: A: B:
COMPLIES IF A >B Yes ❑ No ❑
Rules for Determining Residential Kitchen Luminaire Wattage
Screw Base Sockets §130(c) 1
(Not containing permanently insalled ballasts) The maximum relamping rated wattage of the luminaires, as listed on a permanent
factory -installed label (luminaire wattage is not based on type or wattage of lamp that is used).
Permanently or Remotely installed Ballasts §130(c) 2
The operating input wattage of the rated lamp/ballast combination based on values published in manufacturer's catalogs based on
independant testing lab reports.
Line Voltage Track Lighting (90 through 480 volts) § 130(c) 3
1. Volt-ampere (VA) rating of the branch circuit(s) feeding the tracks; or
2. For tracks equipped with an integral current limiter, the higher of,
• The wattage (or VA) rating of an approved integral current limiter controlling the track system or
• 15 watts per linear foot of the track; or
3. For tracks without an integral current limiter, the higher of,
• 45 W per 1 inear foot of the track or
• The total wattage of all of the luminaires included in the system.
Low Voltage Track Lighting (less than 90 volts) § 130(c) 4
Rated wattage of the transformer feeding the system, as shown on a permanent factory -installed label
Other Lighting § 130(c) 4
(Lighting systems that are not addressed in 130 (c) 1-4) The maximum rated wattage, or operating input wattage of the system,
listed on a permanent factory -installed label, or published in the manufacturer's catalogs, based on independent testing lab reports.
EXAMPLE
Residential Kitchen Lighting
Worksheet WS -5R
Project Title
Date
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
Luminaire Type High Efficacy (y/n)
Watts x Quantity = High Efficacy Watts or Other Watts
EXISTING
x = or
x = or
x = or
Total: A: B:
COMPLIES IF A > B Yes g No ❑
FENESTRATION - MAXIMUM ALLOWED AREA WORKSHEET WS -4R
Project Title
Stidham Family Trust Residence
Date
I April 2, 2003
FENESTRATION PRODUCTS - NEW CONSTRUCTION - NEW BUILDINGS
Use this table for new building construction to account for total huildino 0/ of feneCtrAtlnn
A
B
C
D
E
F
G
#/Type/Pos.
(Front, Left,
Rear, Right,
Skylight)
Orientation
Total
Fenestration,
West Facing
Area (ftz)
Total Fenestration
for N, S, E
Orientations Area
(ft2)
CFA
(ft2)
Total Percent of
West Facing
Fenestration'
(C/E) x 100%
Total % of
Fenestration
Including West
(D/E) x 100%+ F
Total % of
Wes` Facing
Fenestration z
(G/0x100%
North
Front
North
247
5.2
5.2
South
North
East
West
South
Totals
East
5.2
5.2
1) It -west tacing area exceeds 5% of CFA in climate zones 2, 4, and 7-15, the performance approach mus: be used.
2) If total percent of fenestration exceeds 20% including West facing orientations then performance approach must be used. West
facing area includes skylights tilted to the west or tilted in any direction when the pitch is less than 1:12 for Package D only.
FENESTRATION PRODUCTS - NEW CONSTRUCTION - ADDITIONS
-' El Less than 100 ft. Z Less than or Eaual to 1000 ft2. ❑ Greater 1000 ft2
A
B
C
D
E
F
G
H
#/Type/Pos.
(Front, Left,
Rear, Right,
g
Skylight)
Orientation
Proposed
Pro p
Addition's
CFA2,3
Proposed
Addition's
Fenestration
Area (ft2)4
Fenestration
Area Removed to
make way for
Addition (ft2) z
Total Area
Added
Fenestration z
(D - E)
Total % of
Wes` Facing
Fenestration z
(G/0x100%
Total % of
Fenestra -
tion z s4
(F/C)XI00 %
Front
North
247
5.2
5.2
North
South
South
South
Left
East
5.2
5.2
East
West4
West
West
247
10.4 Total
NOM ADDED
1 4.2 %
1) Additions <_ 100 ft2 are allowed to install up to 50 ft2 of fenestration and are exempt from the 5% west facing and 20% maximum total area
limits and shall meet the U -factor and SHGC requirements of Package D. See Table 8-2 in the Residential Manual. Yote: Leave columns E, F,
G, H, and I blank.
2) Additions <_ 1,000 ft2, the maximum net allowed fenestration is 20% and may be increased additionally by the amount of glazing removed in
the wall that separates the addition from the existing house. However, the total West facing fenestration cannot exceed 5% of the proposed
addition's CFA including skylights oriented in any direction and tilted with a pitch of < 1:12. Column G cannot exceed 5% and Column H
cannot exceed 20%.
3) Additions > 1,000 ft2 must meet Package D requirements. See Table 8-2 and Table 151-C in Appendix B of the RM o_ use Performance Approach.
4) The 5% West orientation restrictions are only for Climate zones 2,4, and 7-15; for Climate zones 2,4, and 7-15 enaer zero (0) in Column E.
FENESTRATION PRODUCTS: ALTERATIONS
Use this table for alterations to an existing building where fenectratinn nrnrhictc iwinrlmmcl nra iv>ina ---A anA / nr nAAr A
A
B
C
D
E
F
G
H------[
.
Existing
CFA
(ft2)
Existing
Orientation
Existing
Area
(ft2)
Removed
Orientation
Removed
Area
(ft2)
Proposed
Installed
Orientation
Proposed
Installed
New Area
(ft2)
Total Net
Fene-qration
♦
(LZ)
(C-E+G)
Total % of ,,2
Fenestration
(H/A) x 100%
Max of 20%
North
North
North
South
South
South
East
East
East
West
West
West
Total
Total
Total
i) wnen 3u or more of tenestration area is added to an existing building, then the fenestration must meet the requirements of Package D.
2) The area requirement for the total fenestration area for the whole building, including the added fenestration, must not
exceed 20% otherwise the Performance Approach must be used. Note: See Section 8.3.3 in the RM for farther details.
Residential Compliance Forms Lecember 2005
DESIGNER:
CLIENT:
DESIGNED BY: T.L.
STRUCTURAL CALCULATIO
FOR
STIDHAM RESIDENCE
A LOFT ADDITION
AT
52575 VIA CASTILE
LA QUINTA, CA. 92253
CITY OF LA QUINTA
BUILDING $ SAFETY DEPT.
APPROVED
FOR CONS UCTION
DATE4(>>,L. v
JOB # 4784
2/6/2008
ar
I
SOUTH WEST CONCEPTS
A & M CONSTRUCTION
ZEYAD FAQIH P.E.
O�QROFESS/olli,
M. ,cq�i F2c
No. 57958 {/
,k Exp. 06-30-015
pl V1
L ��Q-
F pF CA01F
R F STRUCTURAL CONSULTANTS, INC.
75-153 MERLE DRIVE, STE. B, PALM DESERT, CA.
PHONE (760) 836-1000 FAX (760) 831
APR 0 3 208
I
DESIGN CRITERIA (GENERAL)
• 2006 INTERNATIONAL BUILDING CODE/2007 CALIFORNIA BUILDING CODE
• SOIL BEARING PRESSURE ASSUMED 1500 PSF
• EXTERIOR WALLS =15.00 PSF INTERIOR WALLS =10.00 PSF
DESIGN CRITERIA-ROOF/FLOOR LOADING
ROOF SLOPE = 3:12
ROOF LOAD
TILE ROOF =
10.00 psf
PLYWOOD =
2.00 psf
TRUSSES =
3.00 psf
DRYWALL =
2.00 psf
INSULATION =
1.00 psf
MISCELLANEOUS =
2.00 psf
DEAD LOAD =
20.00 PSF
LIVE LOAD =
20.00 PSF
TOTAL ROOF LOAD = 40.00 PSF
FLOOR:
DEAD LOAD = 15.00 psf
LIVE LOAD = 40.00 psf
TOTAL = 55.00 PSF
DECK:
DEAD LOAD = 15.00 psf
LIVE LOAD = 60.00 psf
TOTAL = 75.00 PSF
STAIRS:
DEAD LOAD = 15.00 psf
LIVE LOAD = 100.00. psf
TOTAL = 115.00 PSF
DESIGN CRITERIA -SEISMIC LOADING
LOCATION: LA QUINTA, CA (ZIPCODE: 92253)
SS = 1.500 Sl = 0.600 - SDS = 1.000 Sol = 0.600
SEISMIC DESIGN CATEGORY D
SITE CLASS D (ASSUMED)
OCCUPANCY CATEGORY H
SEISMIC IMPORTANCE FACTOR I =1.00
RESPONSE MODIFICATION COEFFICIENT R = 6.5
AT HARDY FRAME PANEL R = 6.5-
A T
:5AT CANTILEVER STEEL COLUMN R = 1.5
REDUNDANCY FACTOR p =1.30 .
BASE SHEAR V= P x [SDSI/(R)] x W
BASE SHEAR V = 1.30 x [1.000 x 1.0/(6.5)] = 0.200W
(IBC SECTION 1613.5.6)
(IBC SECTION 1613.5.2)
(IBC TABLE 1604.5)
(ASCE 7-05; TABLE 11.5-1)
(ASCE 7-05, TABLE 12.2-1)
(HF CATALOG 6-06-A)
(ASCE 7-05, TABLE 12.2-1)
(ASCE 7-05, SECT. 12.3.4.2)
(ASCE 7-05,, EQU. 12.8-1 & 12.8-2)
DESIGN CRITERIA -WIND LOADING
ASSUMED MOST CONSERVATIVE ROOF ANGLE = 200
pS30 = 17.8 PSF (ASCE 7-05, FIGURE 6-2)
WIND EXPOSURE CATEGORY C (ASCE 7-05, SECT. 6.5.6.3)
WIND IMPORTANCE FACTOR I =-1.00 (ASCE 7-05; TABLE 6 -1) -
BASIC WIND SPEED 90 MPH (ASCE 7-05, FIGURE 6-1)
TOPOGRAPHIC FACTOR KZT = 1.00(ASCE 7=05; SECT. 6.5.7.2)
WIND FACTOR ps = X x KZT x I x PS30 (ASCE 7-05, EQU. 6-1)
HEIGHT 15 ft (k
MAXIMUM HEIGHT 20 ft (,%
HEIGHT 25 ft (k
MAXB" HEIGHT 30 ft (k
1.21) WIND FACTOR ps = 21.54 psf
1.29) WIND FACTOR ps = 22.97 psf
1.35) WIlVD FACTOR ps = 24.03 psf
1.40) WIND FACTOR ps = 24.92 psf
COMPANY PROJECT
® R.F. Structural Consultants, Inc. Stidham Residence
WoodWorks 75-153 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 Via Castile
SoniVAeirrox WaonnrsICN Feb. 1, 2008 11:54 La Quinta, CA 92253
Beam #1 - Ridge BM at Stairs
Design Check Calculation Sheet
Sizer 2004a
I LOADS ( fbs, psf, or ptf )
Load
Type
Distribution
Magnitude
Location [ft)
Pat -
Shear
699
Total
Start End
Start End
tern
Loadl
Dead
Full Area
20.00 (6.50)*
LC number
No
Load2
Live
Full Area
20.00 (6.50)*
No
MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) :
V
Dead
699
Value
Design
Live
650
Shear
699
Total
1349
170
650
Bearing:
fb =
785
1349
LC number
2
Dead Defl'n
0.10 =
Length
1.00
2
Live Defl'n
0.09 =
<L/999
1.00
Timber -soft, D.Fir-L, No. 1, 6x8"
Self Weight of 9.8 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) rune,2nna .
Criterion
Analysis
Value
Design
Value
Anal sis/Desi n
Shear
fv =
43
Fv' =
170
fv/Fv' = 0.25
Bending(+)
fb =
785
Fb' =
1200
fb/Fb' = 0.65
Dead Defl'n
0.10 =
<L/999
Live Defl'n
0.09 =
<L/999
0.33 =
L/360
0.28
Total Defl'n
0.20 =
L/611
0.50 =.
L/240
0.39
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1200 1.00 1.00 1.00 1.000.1.000 1.00 1.00 1.00 1.00 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00- -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 3372 lbs -ft
Shear : LC# 2 = D+L, V = 1349, V design = 1180 lbs
Deflection: LC# 2 = D+L EI= 309e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verity that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT y y
® R.F. Structural Consultants, Inc. Stidham Residence
WoodWorks75-153 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 Via Castile
somvnae;ryx woannt'srcn Feb. 4, 2008 08:41 La Quinta, CA 92253
Beam #2 - Drop BM at Loft
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psi, or ptf )
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
1332
Total
Start End
Start End
tern
Loadl
Dead
Full Area
15.00 (8.50)*
LC number
No
Load2
Live
Full Area
40.00 (8.50)*
No
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
u
Dead
1332
Value
Design
Live
3060
Shear
1332
Total
4392
190
3060
Bearing:
.fb =
1129
4392
LC number
2
Dead Defl'n
0.16 =
Ler, th
1.00
2
Live Defl'n
0.37 =
L/576
1.00
Glulam-Unbal., West Species, 24F -1.7E WS, 8-3/4x12" t,4)/ STi9i+lDf�k�
Self Weight of 20.47 pif automatically included in loads; CAM 66K
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (osil and Deflection (in% Kine -2nn4 .
Criterion
Analysis
Value
Design
Value
Anal sis/Desi n
Shear
£v =
56
FV' =
190
fv/Fv` = 0.29
Bending(+)
.fb =
1129
Fb' =
2310
fb/Fb' = 0.49
Dead Defl'n
0.16 =
<L/999
Live Defl'n
0.37 =
L/576
0.60 =
L/360
0.62
Total Defl'n
0.54 =
L/401
0.90 =
L/240
0,60
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CV Cfu ' Cr Cfrt Notes Cn LC#
Fb'+ 2400 1.00 1.00 1.00 1.000 0.963 1.00 1.00 1.00 1.00 - 2
Fv' 190 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 500 - 1.00 1.00 - - - - 1.00 -- -
E' 1.1 million 1.00 1.00_ - - - - 1.00 - - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M 19763 lbs -ft
Shear LC# 2 = D+L, V = 4392, V design = 3904 lbs
Deflection: LC# 2 = D+L EI= 2142e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSI/AITC A190.1-1992
3. GLULAM: bxd = actual breadth x actual depth.
4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3.
5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n).
COMPANY PROJECT !J 2e Y
R.F. Structural Consultants, Inc. Stidham Residence ! r
WoodWorks 75-153 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 Ua Castile
IFeb. 13, 2008 07:00 La Quinta, CA 92253
Beam #3 - Flush BM at Rear of
Upstairs Landing
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or plf )
MAXIMUM REACTIONS Ibs and BEARING LENGTHS (in):
4� � �i �w�i�� C �`�*r 8�':� 1.��.i'�T.`*F � � r �v r -. 3`��' � 'G�• ���,,.� � C�,�x�y�����y��1' P��x
c,, ".145 � f +���., s� e d N•: .�i.`�£'�,"� �F.a�s � : a �'x-���Tt�> s��� *1,�.,y �'i"�'�,
01 �. n
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
594
931
fb = 784
Total
Start End
Start End
tern
0.04 = <L/999
Loadl
Load2
Load3
Dead
Live
Dead
Full Area
Full Area
Full Area
20.00(12.50)*
20.00(12.50)*
15.00 (9.00)*
2
No
No
No
MAXIMUM REACTIONS Ibs and BEARING LENGTHS (in):
4� � �i �w�i�� C �`�*r 8�':� 1.��.i'�T.`*F � � r �v r -. 3`��' � 'G�• ���,,.� � C�,�x�y�����y��1' P��x
c,, ".145 � f +���., s� e d N•: .�i.`�£'�,"� �F.a�s � : a �'x-���Tt�> s��� *1,�.,y �'i"�'�,
01 �. n
Timber -soft, D.Fir-L, No. 1, 6x6"
Self Weight of 7.19 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2001.
Dead
931
Desi n Value Analysis/ esin
-r -a
Shear
Live
594
931
fb = 784
Total
1525
594
0.04 = <L/999
Bearing:
1525
2
0.16 = L/360 0.15
LC number
Total Defl'n
0.06 = L/945
Length
1.00
2
1.00
Timber -soft, D.Fir-L, No. 1, 6x6"
Self Weight of 7.19 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2001.
ADDITIONAL DATA:
FACTORS:.@ CD CM Ct CL CF C£u Cr Cfrt Ci Cn LC#
Fb'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp', 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 1811 lbs -ft
Shear : LC# 2 = D+L, V = 1525, V design = 1231 lbs
Deflection: LC# 2 = D+L EI= 122e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Criterion
Analysis Value
Desi n Value Analysis/ esin
Shear
fv = 61
Fv' = 170 fv/Fv' = 0.36
Bending(+)
fb = 784
Fb' = 1200 fb/Fb' = 0.65
Dead Defl'n
0.04 = <L/999
Live Defl'n
0.02 = <L/999
0.16 = L/360 0.15
Total Defl'n
0.06 = L/945
0.24 = L/240 0.25
ADDITIONAL DATA:
FACTORS:.@ CD CM Ct CL CF C£u Cr Cfrt Ci Cn LC#
Fb'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp', 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 1811 lbs -ft
Shear : LC# 2 = D+L, V = 1525, V design = 1231 lbs
Deflection: LC# 2 = D+L EI= 122e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT
R.F. Structural Consultants, Inc. Stidham Residence
Wood'Works 75-153 Merle Drive, Suite B Remocel/Addition
Palm Desert, CA 92211 52575 Via Castile
scrmv�er<roxwaonnrucn Feb. 4, 2008 12:20 La Quilta, CA 92253
Beam #4 - Flush BM at Kitchen
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or ptf )
Load
Type.
Distribution
Magnitude
Start End
Location [ft1
Start End
Pat -
tern
Loadl
Dead
Full Area
20.00 (2.00)*
Fv' =
No
Load2
Live
Full Area
20.00 (2.00)*
Length
No
Load3
Dead
Point
950
15.25
No
Load4
Live
Point
600
15.25
No
Load5
Dead
Partial Area
15.00 (2.50)*
15.25 20.00
No
Load6
Live
Partial Area
40.00 (2.50)*
15.25 20.00
No
Load7
Dead
Partial Area
15.00 (9.00)*
15.25 20.00
No
Load8
Dead
Point
175
20.00
No
Load9
Live
Point
950
20.00
No
MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) :
I
1),0'
Dead
1084
Value
2088
Live
805
Cfrt Notes Cn
2100
Total
Bearing:
1889
Fv' =
4188
LC number
2
Bending(+)
2
Length
1.00
2324
1.24
Glulam-Unbal., West Species, 24F -1.7E WS, 6-3/4x12" W�• X41-WAXP-
Self Weight of 15.79 pif automatically included in loads; CAM 6 Ck
End notches: top (depth = 3, unsupp. length, e = 12, in); Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) usinn runs 2nn, -
Criterion
Analysis
Value
Desi n
Value
Analysis/Desig n
Cfrt Notes Cn
Shear
fv =
76
Fv' =
,190
fv/Fv' = 0.40
- -
Bending(+)
fb =
1308
Fb' =
2324
fb/Fb' = 0.56
E' 1.7 million 1.00 1.00 - -
Dead Defl'n
0.47 =
L/559
Custom duration factor for Wind load = 1.33
Live Defl'n
0.36 =
L/732
0.73 =
L/360
0.49
Total Defl'n
0.83 =
L/317
1.10 =
L/240
0.76
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CV
Cfu Cr
Cfrt Notes Cn
LC#
Fb'+ 2400 1.00 1.00 1.00 1.000 0.968
1.00 1.00
1.00 1.00 -
2
Fv' 190 1.00 1.00 1.00 - -
- -
1.00 1.00 1.00
2.
Fcp' 500 - 1.00 1.00 - -
- -
1.00 - -
-
E' 1.7 million 1.00 1.00 - -
- -
1.00 - -
2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 17662 lbs -ft
Shear notched end did not control
Shear LC# 2 = D+L, V = 4188, V design
= 4092 lbs
Deflection: LC# 2 = D+L EI= 1652e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection)
+ Live Load
Deflection.
(D=dead L=live S=snow W=viind I=impact C=construction
CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSI/RITC A190.1-1992
3. GLULAM: bxd = actual breadth x actual depth.
4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3.
5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n).
' A 'O ®
Wood V \ /C
o
Type
COMPANY
R.F. Structural Consultants, Inc.
75-153 Merle Drive, Suite B
PROJE=,T
Stidharr Residence
Remodel/Addition
G
V J
' S0fI11AlLPfUF WUUAUfSlCN
Shear
Palm Desert, CA 92211
Feb. 4, 2008 09:05
52575 Via Castile
La Quir?ta, CA 92253
Start End
Start End
tern
Loadl
Beam #5 - Flush BM at Front of
Full Area
15.00 (4.00)*
LC number
Upstairs Landing
Load2
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or plf )
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
950
Total
Start End
Start End
tern
Loadl
Dead
Full Area
15.00 (4.00)*
LC number
No
Load2
Live
Full Area
100.00 (4.00)*
No.
MAXIMUM R
0' A'_0"
Dead
166
Value
166
Live
950
Shear
950
Total
1116
170
1116
Bearing:
fb
= 308
Fb' =
LC number
2
Dead Defl'n
2
Length
1.00
1.00
Timber -soft, D.Fir-L, No. 1, 6x8" j
Self Weight of 9.8 pif automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) usinn NDS 2nn1
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv
= 30
Fv' =
170
fv/Fv' = 0.18
.Bending(+)
fb
= 308
Fb' =
1200
fb/'Fb' = 0.26
Dead Defl'n
0.00
= <L/999
Live Defl'n
0.01
= <L/999
0.16 =
L/360
0.09
Total Defl'n
'0.02
= <L/999
0.24 =
L/240
0.07
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC#. 2 = D+L, M = 1325 lbs -ft
Shear : LC# 2 = D+L, V = 1116, V design = 822 lbs
Deflection: LC# 2 = D+L EI= 309e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
®,
Wood'Works
Type
COMPANY
R.F. Structural Consultants, Inc.
75-153 Merle Drive, Suite B
PROJECT
Stidharn Residence
Remodel/Addition
q7a
SOFItVAVE O[f W006 a5k;N
Loadl
Palm Desert, CA 92211
Feb. 4, 200809:30
52575 Mia Castile
La Quirita, CA 92253
15.00(12.00)*
285
No
Load2
Beam #5 - Drop BM at Left.of Dining
Point
3550
8.00
Room
Load3
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or plf )
Load
Type
Distribution
Magnitude
Start End
Location [ft]
Start, End
Pat -
tern
Loadl
Dead
Full Area
15.00(12.00)*
285
No
Load2
Dead
Point
3550
8.00
No
Load3
Live
Point
3050
8.00
No
Load4
Dead
Full Area
15.00 (6.50)*
L/360
No
Load5
Live
Full Area
1 40.00 (6.50)*
L/240
No
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
o'
Dead
4270
Value
4216
Live
3661
Shear
3614
Total
7931
285
7830
Bearing:
fb =
2433
Fb' =
2
fb/Fb' = 0.87
Dead Defl'n
LC number
Len th
2.01
2
Live Defl'n
0.25 =
L/795
1.99
PSL, 2.OE, 290OFb, 5-1/4x16"
Self Weight of 26.25 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
I Analysis vs. Allowable Stress (psi) and Deflection lin) ueinn NrLS 9nn1
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv =
128
Fv' =
285
fv/Fv' = 0.45
Bending(+)
fb =
2433
Fb' =
2810
fb/Fb' = 0.87
Dead Defl'n
0.29 =
L/681
Live Defl'n
0.25 =
L/795
0.54 =
L/360
0.45
.Total Defl'n
0.53 =
L/367
0.81 =
L/240
0.65
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL Cv Cfu Cr Cfrt Ci Cn LC#
Fb'+ 2900 1.00 - 1.00 1.000 0.97 - 1.00 1.00 - - 2
Fv' 285 1.00 - 1.00 - - - - 1.00 - 1.00
Fcp' 750 - - 1.00 - - - - 1.00 - - -
E' 2.0 million - 1.00 - - - - 1.00 - - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 45408 lbs -ft
Shear : LC# 2 = D+L, V = 7931, V design = 7180 lbs.
Deflection: LC# 2 = D+L EI= 3584e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. SCL-BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design contact your local
SCL manufacturer.
3. Size factors vary from one manufacturer to another for SCL materials. They can be changed in the database editor.
MPANY PROJECTWoodWorks® co
poli I- .�//�
SOFTWARE FOR WOOD DESIGN Y//� /�/_ �/
Mar. 26, 2008 14:59 Be��'• (-r( r,/'V/}, J
C97.wo_ f
Design Check Calculation Sheet
Sizer 2004a
LOADS l lbs, psf, or pif )
Load
Type
Distribution
Magnitude
Start End
Location [ft]
Start End
Pat -
tern
Loadl
Dead
Full Area
15.00(12.00)*
2638
No
Load2
Dead
Point
950
11.00
No
Load3
Live
Point
600
11.00
No
Load4
Dead
Point
175
15.75
No
Loads
Live
Point
950
15.75
No
Load6
Dead
Partial Area
15.00 (2.50)*
11.00 15.75
No
Load?
Live
Partial Area
40.00 (2.50)*
11.00 15.75
No
Load8 lWind
*
jPoint
2250
13.00
_s.w�l 4e�
Tributary Width (ft)
Dead
1928
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
2544
0'
6_Y
568
Timber -soft, D.Fir-L, No. 1, 6x12"
Self Weight of 15.02 pif automatically included in loads;
Lateral support: top= at supports, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2001:
Criterion
Dead
1928
Anal sis/Desi n
2544
Shear
Live
568
fv* Fv' = 0.49
2638
fb = 1266
Fb' = 1327
Total
2496
5182
0.22 = L/893
0.54 = L/360
Bearing:
Total Defl'n
0.62 = L/316
3
0.76
3
LC number
Length
1.00
1.51
Timber -soft, D.Fir-L, No. 1, 6x12"
Self Weight of 15.02 pif automatically included in loads;
Lateral support: top= at supports, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2001:
Criterion
Analysis Value
Design Value
Anal sis/Desi n
Shear
fv* = 83
Fv' = 170
fv* Fv' = 0.49
Bending(+)
fb = 1266
Fb' = 1327
fb/Fb' = 0.95
Live Defl'n
0.22 = L/893
0.54 = L/360
0.40
Total Defl'n
0.62 = L/316
0.81 = L/240
0.76
-due eiieut or point loads within a distance d of the support
has been included as per NDS 3.4.3.1
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1350 1.00 1.00 1.00 0.983 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 3
Bending(+): LC# 2 = D+L, M = 12790 lbs -ft
Shear : LC# 2 = D+L, V = 4262, V design* = 3493 lbs
Deflection: LC# 3 = D+.75(L+W) EI= 1115e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
72
F��
COMPANY PROJECT Y
WoodWorksR.F. Structural Consultants, Inc. Stidham Residence
75-153 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 -Via Castile
5013cr,�.riF:r'ox WOOD bt"stGA Feb. 4, 2008 09:37 La Quinta, CA 92253
Beam #7 - Drop BM at Right of
Kitchen
Design .Check. Calculation _S.heet
Sizer 2004a
LOADS ( lbs, psf, or ptf )
Load
Y
Type
Distribution
Magnitude
Start End
Location (ft)
Start End
Pat -
tern
Loadl
Dead
Full Area
15.00(12.00)*
No
'Load2
Dead
Point
950
11.00
No
Load3
Live
Point
600
11.00
No
Load4
Dead
Partial Area
15.00 (2.50)*
11.00 15.75
No
Load5
Live
Partial Area
40..00 (2.50)*
11.00 15.75
140
Load6
Dead
Point
175
15.75
No
Load?
*Tributar W'dth
Live
f
Point
950
15.75
No
1 ( t)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
9�xws�t-r*' r�
0'
Dead 1928
Live 307 2544
Total 2236 1718
Bearing: 4262
LC number 2
Length 1 1.001 2
1.24
Timber -soft, D.Fir-L, No. 1, 6x12"
Self Weight of 15.02 plf automatically included In loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) usinn pins grin,
-••�2C 0 Pc -c- ivads within a distance d of the support
has been included as per NDS 3.4.3.1
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1350 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 12790 lbs -ft
Shear : LC# 2 = D+L, V = 4262, V design* = 3493 lbs
Deflection: LC# 2'= D+L EI= 1115e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Criterion
Analysis Value
Design Value Anal sis/Desi n
Shear
fv* = 83
Fv' = 170 fv*/Fv' = 0.49
Bending(+)-
fb = 1266
Fb' = 1350 fb/Fb' = 0.94
Dead Defl'n
0.40 = L/489
Live Defl'n
0.11 = <L/999
0.54 = L/360 0.21
Total Defl'n
0.51 = L/380
0.81 = L/240 0.63
-••�2C 0 Pc -c- ivads within a distance d of the support
has been included as per NDS 3.4.3.1
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1350 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 12790 lbs -ft
Shear : LC# 2 = D+L, V = 4262, V design* = 3493 lbs
Deflection: LC# 2'= D+L EI= 1115e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY
® R.F. Structural. Consultants, Inc.
Wood'Works 75-153 Merle Drive, Suite B
Palm Desert, CA 92211
sorlw�$e,rox woM nt'sreN Feb: 4; 2008.1.1:07
Design Check Calculation Sheet
Sizer 2004a
LOADS ( tbs, psf, or ptf )
Load
Type
Distribution
Magnitude
Start End
Location [ft]
Start End
Pat -
tern
Loadl
Dead
Point
700
1.25
No
Load2
Live
Point
650
1.25
No
Load3
Live
Partial Area
20.00(11.50)*
0.00 1.25
No
Load4
Live
Partial Area
20.00(11.50)*
0.00 1.25
No
.Loads
Dead
Partial Area
15.00 (1.50)*
1.25 3.75
No
Load6
Live
Partial Area
100.00 (1.50)*
1.25 3.75
No
Load?
Dead
Point
2100
1.25
No
Load8
Live
Point
2100
1.25
No
MAXIMUM
PROJECT 7 7-0 )�
Stidham Residence.
Remodel/Addition 12
52575 Via Castile
La Quinta; CA 92253
Beam #12- HDR at Front of Kitchen
Dead
1904
Value
-
Live
2437
Shear
989
Total
4341
170
1262
Bearing:
fb
= 1178
2252
2
fb/Fb' = 0.98
Dead Defl'n
LC number
Length
1.26
2
Live Defl'n
0.02
= <L/999
1.00
Timber -soft, D.Fir-L, No. 1,' " u_s& ; 4';V-10
Self Weight of 9.8 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) lien„ ninc 7nni
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv
= 148
Fv' =
170
fv/Fv' = 0.87
Bending(+)
fb
= 1178
Fb' =
1200
fb/Fb' = 0.98
Dead Defl'n
0.02
= <L/999
Live Defl'n
0.02
= <L/999
0.13 =
L/360
0.14
Total Defl'n
0.03
= <L/999
0.19 =
L/240
0.17
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
tv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+); LC# 2 = D+L, M = 5060 lbs -ft
Shear : LC# 2 = D+L, V = . 4341, V design = 4063 lbs
Deflection: LC# 2 = D+L EI= 309e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT
® R.F. Structural Consultants, Inc. Stidham Residence 9
WoodWorks 75-15.3 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 Via Castile
$0FnvAxr<roaWOOO MION Feb. 4, 200810:14 La Quinta, CA 92253
Beam #9 - HDR at Right of Stairs
Design Check Calculation Sheet
Sizer 2004a
'LOADS ( lbs, psf, or pt()
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
81
Total
Start End
Start End
tern
Load3
Dead
Full Area
15.00(12.00)*
1200
No
Load2
Dead
Point
700
0.75
No
Load4
Live
Point
650
0.75
No
-iLlvUUaLy vvlULII tLL)
MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) :
01
r"
Dead
1182
Value
657
Live
569
Shear
81
Total
1751
170
738
Bearing:
fb
= 334
Fb' =
1200
fb/Fb' = 0.28
Dead Defl'n
0.02
LC 'number
2
-
2
Length
1.00
= <L/999
1.00
Timber -soft, D.Fir-L, No. 1, 6x8"
Self Welght of 9.8 plf automatically Included In loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress. (psi) and Deflection (in) usino NDS 2001:
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv
= 59
Fv' =
170
fv/Fv' = 0.35
Bending(+)
fb
= 334
Fb' =
1200
fb/Fb' = 0.28
Dead Defl'n
0.02
= <L/999
Live Defl'n
0.01
= <L/999
0.20 =
L/360
0.03
Total Defl'n
0.03
= <L/999
0.30 =
L/240
0.10
ADDITIONAL DATA:
FACTORS: F CD CM - Ct CL CF Cfu Cr Cfrt Ci . Cn LC#
Fb.'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 .1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 1435 lbs -ft
Shear : LC# 2 = D+L, V = 1751, V design = 1632 lbs
Deflection: LC# 2 = D+L EI= 309e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection)'+ Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT G/
® R.F. Structural Consultants, Inc. Stidham Residence tI A
Wood'Works
75-153 Merle Drive, Suite B Remodel/Addition Palm Desert, CA 92211 52575 Via Castile
SOFI1YAWFI P8 WPPAMIGN Feb. 4, 200810:27 La Quinta, CA 92253
Beam #10 - HDR at Front of Dining
Room
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or pif) =
Load
ib t W'
Type
Distribution
Magnitude
Start End
Location (ft)'
Start End
Pat -
tern
Loadl
Dead
Full Area
20.00 (6.00)*
No
Load2
Live
Full Area
20.00 (6.00)*
Dead Defl'n
No
Load3
Dead
Full Area
15.00(12.00)*
0.06 = <L/999
No
Load4
Dead
Point
650
3.00
No
Loads
Dead
Point
1200
4.50
No
Load6
Live
Point
575
4.50
No
Load7
Dead
Partial Area
20.00 (6.50)*
4.50 10.25
No
Load8
*T
Live
Partial Area
20.00 (6.50)*
4.50 10.25
No
ru ary idth (ft)
MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in)':
rc'ik�i��}��.��� �'�3. Yrx,�� �� £.�L�' '��'�' �."�i��"�3„'�&�.s'smz•2 �sa-.� 'zr' � y. `�}'�'i"�`�,`�
0'
10'x"
Dead 2957
Live 1197
2869
Total 9109
1405
Bearing: 4275
LC number 2
Length 1.19
2
1.24
Timber -soft, D.Fir-L, Nolde�din
V -S /��`- 'y k
Self Weight of 15.02 plf automatically loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2001
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1350 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 13089 lbs -ft
Shear : LC# 2 = D+L, V = 4104, V design = 3676 lbs
Deflection: LC# 2 = D+L EI= 1115e.0.6 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Criterion
Anal sis Value
Desi n Value Anal sis/Desi n
Shear
fv = 87
Fv' = 170 fv/Fv' = 0.51
Bending (+)
fb = 1296
Fb' = 1350 fb/Fb' = 0.96
Dead Defl'n
0.15 = L/843
Live Defl'n
0.06 = <L/999
0.34 = L/360 0.19
Total Defl'n
0.21 = L/587
0.51 = L/240 0:41
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 1350 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 13089 lbs -ft
Shear : LC# 2 = D+L, V = 4104, V design = 3676 lbs
Deflection: LC# 2 = D+L EI= 1115e.0.6 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT I/ -7s y
R.F. Structural Consultants, Inc. Stidham Residence
WoodWorks'
75-153 Merle Drive, Suite B Remodel/Addition
Palm Desert, CA 92211 52575 Via Castile
scu9wArr:xoaWOOD nrsrcn Feb. 13, 2008 09:33 La Quinta, CA 92253
Beam #11 - High HDR at Front of
Stairs
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or plf )
Load
Type
Distribution
Magnitude
Location Ift)
Pat -
Shear
1065
Total
Start End
Start End
tern
Loadl
Dead
Full Area
20.00 (8.50)*
LC number
No
Load2
Live
Full Area
20.00 (8.50)*
- 1.00
No
Load3
Dead
Full Area
15.00(14.00)*
L/360
No
MAXIMUM REACTIONS
9
and BEARING LENGTHS (in):
Dead
1065
Value
Design
Live
468
Shear
1065
Total
1532
170
468
Bearing:
fb =
912
1532
LC number
2
Dead Defl'n
0.07 =
Length 1
1.00
- 1.00
2
Live Defl'n
0.03 =
<L/999
1.100
Timber -soft, D.Fir-L, No. 1,�6-� �, 6X Q
Self Weight of 7.19 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (osil and Deflection (in) iscinn tinQ -jnn, .
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv =
63
Fv' =
170
fv/Fv' = 0.37
Bending(+)
fb =
912
Fb' =
1200
fb/Fb' = 0.76
Dead Defl'n
0.07 =
<L/999
1.00 - - -
- 1.00
1.00
Live Defl'n
0.03 =
<L/999
0.18 =
L/360
0.16
Total Defl'n
0.09 =
L/701
0.28 =
L/240
0.34
ADDITIONAL DATA:
FACTORS: F CD CM
Ct CL CF Cfu
Cr Cfrt
Ci
Cn LC#
Fb'+ 1200 1.00 1.00
1.00 1.000 1.000 1.00
1.00 1.00
1.00
- 2
Fv' 170 1.00 1.00
1.00 - - -
- 1.00
1.00
1.00 2
Fcp' 625 - 1.00
1.00 - - -
- 1.00
1.00
- -
E' 1.6 million 1.00
1.00 - - -
- 1.00
1.00
- 2
Custom duration factor for
Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 2107.lbs-ft
Shear : LC# 2 = D+L, V = 1532, V design = 1277 lbs
Deflection: LC# 2 = D+L EI= 122e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact 'C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Design Check Calculation Sheet
Sizer 2004a
LOADS ( Ibs, psf, or ptf )
Load
Type
COMPANY
R.F. Structural Consultants, Inc.
PROJECT
Stidham
/
WoodWorks®
Shear
75-153 Merle Drive, Suite B
Residence
Remodel/Addition
z
Start End
tern
Palm Desert, CA 92211
52575 Via Castile
Full Area
snrtw�eFFoawotasnrury
LC number
Feb. 13, 2008 09:36
La Quinta, CA 92253
Live
Full Area
100.00 (1.50)*
Beam #12 - Low Flush Stair Landing
Live Defl'n
0.04 =
<L/999
BM at Front of Stairs
L/360
Design Check Calculation Sheet
Sizer 2004a
LOADS ( Ibs, psf, or ptf )
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
413
Total
Start End
Start End
tern
Loadl
Dead
Full Area
15.00 (1.50)*
LC number
No
Load2
Live
Full Area
100.00 (1.50)*
No
MAXIMUM REQ
CTIONS (lbs) and BEARING LENGTHS (in):
0'
S'_R"
Dead
74
Value
79
Live
413
Shear
413
Total
487
180
487
Bearing:
2
455
2
LC number
Length
1.00
0.01 =
1.00
Lumber -soft, D.Fir-L, No.2, 4x6"
Self Weight of 4.57 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) usmo Nos 2001 :
Criterion
Analysis
Value
Desi n
Value
Analysis/Design
Shear
fv -
32
Fv' =
180
fv/Fv' = 0.18
Bending(+)
fb =
455
Fb' =
1170
fb/Fb' = 0.39
Dead Defl'n
0.01 =
<L/999
Live Defl'n
0.04 =
<L/999
0.18 =
L/360
0.22
Total Defl'n
0.05 =
<L/999
0.28 =
L/240
0.17
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 900 1.00 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 670 lbs -ft
Shear : LC# 2 = D+L, V = 487, V design = 406 lbs
Deflection: LC# 2 = D+L EI= 78e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or pff )
Load
Type
COMPANY
PROJECT
Location [ft]
®
WoodWorks
fv
R.F. Structural Consultants, Inc.
75-153 Merle Drive, Suite B
Stidham Residence
Remodel/Addition
Start End
Start End
tern
Palm Desert, CA 92211
52575 Va Castile
Point
1175
1.25
Feb. 13, 200816:31
La Quinta, CA 92253
Live
Point
350
1.25
Beam #13 - Flush BM at Left of Stairs
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or pff )
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
fv
80
Total
Start End
Start End
tern
Loadl
Dead
Point
1175
1.25
No
Load2
Live
Point
350
1.25
No
Load3
Dead
Full Area
15.00 (9.00)*
0.04
No
;iriouLary wiaLn (rL)
I IXIIIIllhJ1,II 44.-
CTIONS lbs and BEARING LENGTHS (in):
����,���� `"�, :}, ���� r..�� 'Sir �,��� ,� ✓'� � ,,,t {� d� i"� M' kv�- �� y'�.r���' ��i�`*r���� �'',
51
Dead
1296
Desi n
655
Live
270
fv
80
Total
1566
fv/Fv' = 0.49
734
Bearing:
= 723
Fb' =
1170
fb/Fb' = 0.62
Dead Defl'n
0.04
= <L/999
LC number
2
2
Length
1.00
0.18 =
1.00
Lumber -soft, D.Fir-L, No.2, 4x8"
Self Weight of 6.03 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) usina NDS 2001:
Criterion
Analysis Value
Desi n
Value
Analysis/Design
Shear
fv
= 88
Fv' =
180
fv/Fv' = 0.49
Bending(+)
fb
= 723
Fb' =
1170
fb/Fb' = 0.62
Dead Defl'n
0.04
= <L/999
Live Defl'n
0.01
= <L/999
0.18 =
L/360
0.04
Total Defl'n
0.05
= <L/999
0.28 =
L/24-0
0.18
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 900 1.00 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 1847 lbs -ft
Shear : LC# 2 = D+L, V = 1566, V design = 1481 lbs
Deflection: LC# 2 = D+L EI= 178e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W --wind I=impact C=construction CLd=concentrated)
(A11 LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
H
COMPANY PROJECT 7 ��
R.F. Structural Consultants, Inc. Stidham Residence ASL
WoodWorks75-153 Merle Drive, Suite B Remodel/Addition 7
Palm Desert, CA 92211 52575 Via Castile
sc�nnvlere,rvewoonntsrcn Feb. 1, 200811:32 La Quinta, CA 92253/
Typ. Roof Rafter (1) \'
Design Check Calculation Sheet
Sizer 2004a
'LOADS ( Ibs, psf, or pff )
Load
Type
Distribution
Magnitude
Location (ft]
Pat -
Shear
93
Total
Start End
Start End
tern
Loadl
Dead
Full Area
20.00 (16.0)*
LC number
No
Load2
Live
Full Area
20.00 (16.0)+
No
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS
01
7'
Dead
100
Value
100
Live
93
Shear
93
Total
194
180
194
Bearing:
fb =
537
Fb' =
LC number
2
Dead Defl'n
0.05 =
Length
1 1.00
1.00
Lumber -soft, D.Fir-L, No.2, 2x6"
Spaced at 16" c/c; Self Weight of 1.96 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using Nos 2001 :
Criterion
Anal sis
Value
Design
Value
Analysis/Design
Shear
fv =
31
Fv' =
180
fv/Fv' = 0.17
Bending(+)
fb =
537
Fb' =
1345
fb/Fb' = 0.40
Dead Defl'n
0.05 =
<L/999
Live Defl'n
0.04 =
<L/999
0.35 =
L/240
0.12
Total Defl'n
0.09 =
L/935
0.35.=
L/240
0.26
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 900 1.00 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 2
Fv' 180 1.00 1..00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 339 lbs -ft
Shear : LC# 2 = D+L, V = 194, V design = 168 lbs
Deflection: LC# 2 = D+L EI= 33e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT � /
ks
R.F. Structural Consultants, Inc. Stidharr, Residencewood n oc 15
75-153 Merle Drive, Suite B Remodel/Addition
V v Palm Desert, CA 92211 52575 Via Castile
SSlF7tYA1tFWHWOM1Ot]fGN Feb. 1, 2008 11:34 La Quinta, CA 92253
Typ. Rcof Rafter (2)
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or ptf )
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
300
Total
Start End
Start End
tern
Loadl
Dead
Full Area
20.00 (24.0)*
.LC number
No
Load
Live
Full Area
20.00 (24.0)*
No
"111UULtlLy W1ULfl \111)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
0' 4 M.
Dead
330
Value
330
Live
3170
Shear
300
Total
630
180
630
Bearing:
fb =
896
Fb' =
.LC number
2
Dead Defl'n
2
Length
1.00
1.00
Lumber -soft, D.Fir-L, No.2, 2x12"
Spaced at 24" c/c; Self Weight of 4.01 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) iminn rune,2nn, .
Criterion
Analysis
Value
Desi n
Value.
Anal sis/Desi n
Shear
fv =
49
Fv' =
180
fv/A, = 0.27
Bending(+)
fb =
896
Fb' =
1035
fb/Fb' = 0.87
Dead Defl'n
0.18 =
<L/999
Live Defl'n
0.16 =
<L/999
0.75 =
L/240
0.21
Total Defl'n
0.34 =
L/535
0.75 =
L/240
0.45
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 900 1.00 1.00 1.00 1.000 1.000 1.00 1.15 1.00 1.00 - 2
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00. 1.00 - -
- 2
E" 1.6 million 1.00 1.00 - - - - 1.00 1.00
Custom duration factor for Hind load = 1.33
Bending(+): LC# 2 = D+L, M = 2363 lbs -ft
Shear : LC# 2 = D+L, V = 630, V design = 551 lbs
Deflection: LC# 2 = D+L EI= 285e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
WoodWorks
COMPANY
R.F. Structural Consultants, Inc.
75-153 Merle Drive, Suite B
PROJECT
Stidham /��� Residence
Remodel/Addition / 6
somvlerrroawrtoraarsrcn
Palm Desert, CA 92211
Feb. 1, 2008 11:39
52575 Via Castile
La Quinta, CA 92253 �J
Typ. Floor Joist (3) 7
Design Check Calculation Sheet
980
Sizer 2004a
-720
LOADS ( fbs, psf, or ptf )
Bending]+)
Load Type Distribution Magnitude. Location [ft] Pat-
728
Start End Start End tern
15.00 (24.0)*
Leadl Dead Full
No
Load2
Live
*Tributary width (in)
90.00 (24.0)*
MAXIMUM REACTIONS (Ibs) and BEARING (in) :
No
MMIyLJyENGTHMR-gS5�S, y � y
.���p�tk f y 2� yyK� di �.t'1 ', S(•r''}�9 A :�'qY�
�.Y4. r�.,,K M'sC rrM S,.S .f �., ..... 'rc� 5 5�P b `? ..rt. ..........,.
0' 12�
15'
0.05 s <L/999
LC number
2
2
Interior Dead
0
Length
1.00
L/290
1.00
0.16
0.00
0.15 = <L/999
0.63 =
L/240
0.29
Cantil. Dead
0.03 = <L/999
Live
0.06 = L/535
0.25 =
L/120
0.22
Total
0.09 = L/352
0.25 =
L/120
0.34
Lumber-soft, D.Fir-L, No.2, 6x8"
Spaced at 24" c/c; Self Weight of 11.4 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Load combinations: ICC-IBC;
WARNING: this CUSTOM SIZE is not in the database. Refer to online help.
Analysis vs. Allowable
Stress (psi)
and Deflection
(in) using NDS 2001:
ADDITIONAL DATA:
.FACTORS: F CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fb'+ 900 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fb'- 900 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fv' 180 1.00 1.00 1.00 - -. - - 1.00 1.00 1.00 2
Fcp' 625• - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2
Custom duration factor for Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 2185 lbs-ft
Bending(-): LC# 2 = D+L, M = 379 lbs-ft
Shear : LC# 2 = D+L, V = 789, V design = 708 lbs
Deflection: LC# 2 = D+L EI= 410e06 lb-in2
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
Dead
298
Design
373
Analysis/Design
Shear
Live
980
180
-720
0.12
Bending]+)
Total
728
Area
15.00 (24.0)*
0.46
No
Load2
Live
Full Area
90.00 (24.0)*
0.08
No
Dead
298
Design
373
Analysis/Design
Shear
Live
980
180
-720
0.12
Bending]+)
Total
728
900,
1093
0.46
Bending(-)
Bearing:
Fb' =
900
fb/Fb' =
0.08
Deflection:
0.05 s <L/999
LC number
2
2
Interior Dead
0
Length
1.00
L/290
1.00
0.16
0.00
Criterion
Analysis Value
Design
Value
Analysis/Design
Shear
fv = 22
Fv' =
180
fv/Fv' =
0.12
Bending]+)
fb = 410
Fb' =
900,
fb/Fb' =
0.46
Bending(-)
fb = 71
Fb' =
900
fb/Fb' =
0.08
Deflection:
0.05 s <L/999
Interior Dead
Live
0.10 = <L/999
0.63 =
L/290
0.16
Total
0.15 = <L/999
0.63 =
L/240
0.29
Cantil. Dead
0.03 = <L/999
Live
0.06 = L/535
0.25 =
L/120
0.22
Total
0.09 = L/352
0.25 =
L/120
0.34
DESIGN NOTES: <<
1. Please verify that the default deflection limits are appropriate for your application. ns
2. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the niddle 2/3 of 2 spa beams
and to the full length of cantilevers and other spans.
3. Sewn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. The critical deflection value has been determined using maximum back -span deflection. Cantilever deflections do not govern design.
COMPANY PROJECT
R.F. Structural Consultants, Inc. Stidham Residence 1 Z
WoodWorks° 75-153 Merle Drive, Suite B Remod:UAddition
Palm Desert, CA 92211 52575fa Castile
SOF71VA&r-OR WOOD Of XW Feb. 13, 2008 06:59 La Quirta, CA 92253
Typ. Floor Joist (4) n
Design Check Calculation Sheet
Sizer 2004a
LOADS ( lbs, psf, or plf) .
Load
Type
Distribution
Magnitude
Location [ft]
Pat -
Shear
180
Total
Start End
Start End
tern
Loadl
Dead
Full Area
15.00 (24.0)*
1345
No
Load2
Live
Full Area
40.00 (24.0)*
- - 1.00
No
"rrlDULary w1aLn tin)
ILUX41l4 I INA.,
CTIONS Obs and BEARING LENGTHS (in):
N y�af x � " � '�,aq� •c,yt S� x ' `,�,",#� .sxHe�,�a. �. �, +,,� �h'' � �°`t .tu
�`�tG . .•.. ��Sxi •n b��.�.��,�,+N,�'�' ?J�.*y,+SX�3a�S *�E f a ..,. �, :.� �r��f�:...��a�':��sSY �r�v�i'�v��� . $'+��� �,����x #kfi
0'
4'-6"
Dead
72
Value
72
Live
180
Shear
180
Total
252
180
252
Bearing:
fb
= 450
Fb' =
1345
fb/Fb' = 0.33
Dead Defl'n
0.01
LC number
2
- - 1.00
2
Length
1.00
= <L/999
1.00
Lumber -soft, D.Fir-L, No.2,,�W- V5 F l '",Z*e
14f 0/�
Spaced at 24" c/c; Self Weight of 1.96 plf automatically included in loads;
Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Load combinations: ICC -IBC;
Analysis vs. Allowable Stress (psi) and Deflection (in) using Nos 2001:
Criterion
Analysis
Value
Design
Value
Analysis/Design
Shear
fv
= 36
Fv' =
180
fv/Fv' = 0.20
Bending(+)
fb
= 450
Fb' =
1345
fb/Fb' = 0.33
Dead Defl'n
0.01
= <L/999
1.00 - -
- - 1.00
1.00
Live Defl'n
0.02
= <L/999
0.22 =
L/240
0.10
.Total Defl'n
0.03
= <L/999
0.22 =
L/2.40
0.14
ADDITIONAL DATA:
FACTORS: F CD CM
Ct CL CF
Cfu Cr Cfrt
Ci
Cn LC#
Fb'+ 900 1.00 1.00
1.00 1.000 1.300
1.00 1.15 1.00
1.00
- 2
Fv' 180 1.00 1.00
1.00 - -
- - 1.00
1.00
1.00 2
Fcp' . 625 - 1.00
1.00 - -
- - 1.00
1.00
- -
E' 1.6 million 1.00
1.00 - -
- - 1.00
1.00
- 2
Custom duration factor for
Wind load = 1.33
Bending(+): LC# 2 = D+L, M = 283 lbs -ft
Shear LC# 2 = D+L, V = 252, V design = 201 lbs
Deflection: LC# 2 = D+L EI= 33e06 lb -int
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D --dead L=live S=snow W=wind I=impact C=construction CLd=concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
-���' Sio2�`
MASTER BEDROOM
LATERAL ANALYSIS
NOTE: THE OVERALL HEIGHT OF THE STRUCTURE DOES NOT CHANGE DUE
TO THE INTERIOR ADDITION OF THE LOFT. THEREFORE, THE WIND LOAD
APPLIED TO THE STRUCTURE WILL REMAIN THE SAME. AS A RESULT, THE
EXISTING LATERAL FORCE RESISTING ELEMENTS WILL BE CALCULATED TO
CONFIRM THAT THEY CAN ACCOMMODATE THE ADDED SEISMIC LOAD DUE
TO THE LOFT FLOOR ADDITION.
SECTION #1 LONGITUDINAL
11T FLR HT = 10.00 FT 2ND FLR HT = 18.00 FT ROOF AVG HT = 22.00 FT
WIND FORCE (90 MPH) = 22.97 PSF
WIND LOAD ROOF = 22.97 psf x (4.00 + 4.00 ft) = 184 PLF
WIND LOAD 1 -FL = 22.97 psf x (4.00 ft + 10.00 ft/2) = 207 PLF
TOTAL WIND LOAD = 391 PLF
SEISMIC ROOF:
DL ROOF = 20 x 34.00 = 680
DL EXT WALL = 15.00 x 2 x (18.00 - 14.00) = 120
DL INT WALL = 10.00 x 2 x (18.00 - 14.00) = 80
SEISMIC LOAD= 0.200 x (680 + 120 + 80) = 176 PLF
SEISMIC 1 -FL:
DL FLOOR = 15.00 x 18.00 = 270
DL EXT WALL = 15.00 x (2 x (14.00-10.00/2) = 270
DL INT WALL = 10.00 x (2 x (14.00-10.00/2) = 180
SEISMIC LOAD= 0.200 x (270 + 270 + 180) = 144 PLF
TOTAL SEISMIC LOAD = 320 PLF
REDISTRIBUTE SHEAR: (176 plf x 18.00 ft) + (144 plf x 10.00 ft) = 4608 LBS
SHEAR ROOF = 176 plf x 18.00 ft x 320 plf/ 4608 lbs = 220 PLF
SHEAR 1 -FL = 144 plf x 10.00 ft x 320 plf/ 4608 lbs =100 PLF
ROOF MAX. SHEAR = 220 plf x (34.00 ft)/(2 x 19.00 ft) = 197 PLF
ROOF CHORD FORCE = 220 plfx (34.00 ft**2)/(8 x 19.00 ft) = 1673 LBS
USE (12) 16 D's PER TOP PLATE SPLICE
1 -FL MAX. SHEAR = 207 plf x (14.00 ft)/(2 x 19.00 ft) = 77 PLF
1 -FL CHORD FORCE = 207 plf x (14.00 ft**2)/(8 x 19.00 ft) = 267 LBS
USE (8) 16 D's PER TOP PLATE SPLICE.
LATERAL ANALYSIS
SECTION #1 TRANSVERSE
IST FLR HT = 10.00 FT 2ND FLR HT = 18.00 FT ROOF AVG HT = 22.00. FT
WIND FORCE (90 MPH) = 22.97 PSF
WIND LOAD ROOF = 22.97 psf x (4.00 + 4.00 ft) = 184 PLF
WIND LOAD 1 -FL = 22.97 psf x (4.00 ft + 10.00 ft/2) = 207 PLF
TOTAL WIND LOAD = 391 PLF
SEISMIC ROOF:
DL ROOF = 20 x 34.00 = 680
DL EXT WALL = 15.00 x 2 x (18.00 - 14.00) = 120
DL INT WALL = 10.00 x 2 x (18.00 - 14.00) = 80
SEISMIC LOAD= 0.200 x (680 + 120 + 80) = 176 PLF
SEISMIC 1 -FL:
DL FLOOR = 15.00 x 18.00 = 270
DL EXT WALL = 15.00 x (2 x (14.00-10.00/2) = 270
DL INT WALL = 10.00 x (2 x (14.00-10.00/2) = 180
SEISMIC LOAD= 0.200 x (270 + 270 + 180) = 144 PLF
TOTAL SEISMIC LOAD = 320 PLF
REDISTRIBUTE SHEAR: (176 plf x 18.00 ft) + (144 plf x 10.00 ft) = 4608 LBS
SHEAR ROOF = 176 plf x 18.00 ft x 320 plf/ 4608 lbs = 220 PLF
SHEAR 1 -FL = 144 plf x 10.00 ft x 320 plF 4608 lbs = 100'PLF
ROOF MAX. SHEAR = 220 plf x (18.00 ft)/(2 x 34.00 ft) = 59 PLF
ROOF CHORD FORCE = 220 plf x (18.00 ft* *2)/(8 x 34.00 ft) = 263 LBS
USE (8) 16 D's PER TOP PLATE SPLICE
1 -FL MAX. SHEAR = 207 plf x (18.00 ft)/(2 x 34.00 ft) = 55 PLF
1 -FL CHORD FORCE = 207 plf x (18.00 ft**2)/(8 x 34.00 ft) = 247 LBS
USE (8) 16 D's PER TOP PLATE SPLICE.
LATERAL ANALYSIS
SHEAR WALL #1 2ND STORY --LEFT WALL OF LOFT
TOTAL LOAD = 220 plf x (34.00 ft/2) = 3740 LBS
SHEAR WALL LENGTH = 14.25 + 8.00 = 22.25 FT
SHEAR WALL = 3740 lbs/22.25 ft = 169 PLF
VERIFY (E) SHEAR WALL TYPE 10 WITH 16D's AT 4" O/C SILL PLATE NAILING.
MAX. DRAG LOAD = 1007 LBS. VERIFY EXISTING (8) 16D'S PER TOP PLATE SPLICE.
MAX. UPLIFT LOAD = 903 LBS
NO SIGNIFICANT UPLIFT, NO HOLDOWNS REQUIRED.
SHEAR WALL #2
1sT STORY --LEFT OF DINING ROOM
TOTAL LOAD = [100 plf x (29.00 ft/2) + 3740]/1.4 = 3708 LBS
VERIFY EXISTING SIMPSON WALL, (1) SW 48 x 10.
TOTAL CAPACITY = 3940 LBS .
MAX. DRAG LOAD= 2866 LBS. VERIFY EXISTING (22) 16D'S PER TOP PLATE SPLICE.
SHEAR WALL #3 11T STORY --LEFT OF ENTRY
TOTAL LOAD = 100 plf x (50.00 ft/2) = 2500 LBS
SHEAR WALL LENGTH = 6.00 FT
SHEAR WALL = 2500 lbs/6.00 ft = 417 PLF
VERIFY (E) SHEAR WALL TYPE 12 WITH 5/8" x 12" A.B. AT 12" O/C WITH 2x SILL.
MAX. DRAG LOAD= 1250 LBS. VERIFY EXISTING (12) 16D'S PER TOP PLATE SPLICE.
MAX. UPLIFT LOAD = 3870 LBS
USE SIMPSON HTT22 TO HOLD DOWN EACH END4VERIFY (E).
SHEAR WALL #4 IST STORY --REAR OF GREAT ROOM
TOTAL LOAD = 320 plfx (18.00 ft/2) = 2880 LBS
SHEAR WALL LENGTH = 10.00 FT
SHEAR WALL = 2880 lbs/10.00 ft = 288 PLF
VERIFY (E) SHEAR WALL TYPE 11 WITH 5/8" x 12 A.B. AT 32" O/C.
MAX. DRAG LOAD= 2146 LBS. VERIFY EXISTING (16) 16D'S PER TOP PLATE SPLICE.
MAX. UPLIFT LOAD = 4139 LBS
USE SIMPSON HTT22 TO HOLD DOWN EACH END4VERIFY (E).
23
LATERAL ANALYSIS
SHEAR WALL #5 11T STORY --FRONT OF GREAT ROOM
TOTAL LOAD = 320 plf x (18.00 ft/2) + 220 plf x (12.00 ft/2) = 4200 LBS
SHEAR WALL LENGTH = 12.00 FT
SHEAR WALL = 4200 lbs/12.00 ft = 350 PLF
VERIFY (E) SHEAR WALL TYPE 11 WITH 5/8" x.12" A.B. AT 32" O/C.
MAX. DRAG LOAD= 1977 LBS. VERIFY EXISTING (16) 16D'S PER TOP PLATE SPLICE.
MAX. UPLIFT LOAD = 4140 LBS
USE SIMPSON HTT22 TO HOLD DOWN EACH END4VERIFY (E).
FOOTING DESIGN
ALL FOOTING IS ASSUMED EXISTING, NO NEW FOOTING HAS BEEN ADDED.
THEREFORE, NO FOOTING DESIGN IS REQUIRED.
PAD DESIGN
BM #2 = 4400 LBS
USE 2'-0" SQ. x 12" DEEP PAD WITH (2) #4 BARS EACH WAY
BM #6 + BM #7 = 10175 LBS
USE T-0" SQ. x 12" DEEP PAD WITH (3) #4 BARS EACH WAY
BM #6 + BM #7 + BM #10 = 16300 LBS
USE T-6" SQ. x 12" DEEP PAD WITH (4) #4 BARS EACH WAY
BM #8 = 4350 LBS
USE 2'-0" SQ. x 12" DEEP PAD WITH (2) #4 BARS EACH WAY
BM#11 +BM#12+BM#13 =2775 LBS
USE 2'-0" SQ. x 12" DEEP PAD WITH (2) #4 BARS EACH WAY
RF STRUCTURAL CONSULTANTS, INC.
ppLtA DESERT, CA 92211
75-153 MERLE DRIVE, STE. B, FAX (760) 836-0856
EMAI (76RAYMOND@RFSTRUCTURA36-10 0L•Com
-
RESPONSE
TO BUILDING DEPAR'fMENT REQUESTED CORRECTIONS
MARCH 26, 200
THE STIDHAM RESIDENCE
52575 VIA CASTILE
LA QUINTA, CA.
JOB NO.: 4784
SFA PLAN CHECKNO.: 08-354
STRUCTURAL GENERAL
1- PLEASE SEE THE ATTACHED REVISED PLANS AND CALCULATIONS FOR
STAMP AND SIGNATURE-
2
_ THE PROJECT IS AN ADDED LOFT INSIDE T� ECXIH DOES NOING TE EFFECT THE
WITH A STAIR WAY P�T'LY OUTSIDE,
ENVELOP OF THE BUILDING, THEREFORE SEISMIC DESIGN IS WHATS
REQUIRED.
3- PLEASE SEE THE ATTACHED REVISED PLAN OR THE ADDED DET
AIL
6/SD-1 FOR THE DRAG TO THE SMSON W
4- PLEASE SEE THE REVISED CAI,CULATIONHE jSJpFO�RTO�DIEAR WALL # 1
CALCULATIONS FOR -BEAM # 7, FOR
ABOVE.
ARE OK AS DESIGNED THE 1.25 REDUCTION FACTOR ISNOT
5- THE BEAMS
USED WITH THE FLOOR LOADING.