Loading...
04-4489 (SFD)BUILDING & SAFETY -DEPARTMENT P.O. Box 1504 - (760).777-7012 7-8-495 CALLS TAMPICO y FAX (760) 777-7011 .LA'QUINTA,'CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT CITY DF LA 5U11 FINANCE DEP Application Number . . 04=00004489_ Date 6/02/04 Property Address . . . . _ 44670 VIA CATALINA APN: 604--032-999-83-305212- Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning LOW DENSITY RESIDENTIAL Application valuation 18251.7 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY, 111, STE C. 78401 HIGHWAY 111, SUITE C LA QUINTA, CA LA QUINTA`.'. CA 92253 LA QUINTA CA 92253 - WCC: OLD REPUBLIC IN WC: MWC10877600 .11/01/04 CSLB: 728102 09/30/04 CCC: B f ----------------=---------- Structure Information -----_-------------------- Construction Type TYPE V - NON RATED Occupancy Type, . . . ....DWELLG/LODGING/CONG <=10 Flood Zone . . . . NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CRC FIRE SPRINKLERS NO GARAGE SQ FTG 426,4.00 PATIO*SQ FTG 236.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2990.00 Permit BUILDING PERMIT Additional desc. . Permit Fee 930.00 Plan Check Fee 151.13 Issue Date Valuation .. . . . 182517 Qty Unit Charge Per Extension BASE FEE 639.50 83.00 3.5000 THOU BLDG 100,001-500,000 t 290.50 -------------------- — ----------------------------------- ------------------------------------------------------ ---------------------- Permit Permit MECHANICAL Additional desc Permit Fee 70.50 Plan Check Fee 4.41 Issue Date Valuation. 0 Qty- Uhit Charge Per p nsi JUN 102004 CITY DF LA 5U11 FINANCE DEP P.O. BOX 1504. -- 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Applicant: ryNncdni s mauing Aaaress: Tldf 4 4 a" BUILDING & SAFETY DEPARTMENT VOICE (760) 777-701: FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: % -Q • d� or Engineer: Architect or Engineer's ddress: 1 �Dy s r.r o 4t— 4' 1- Gid °talo I — Lic. No.: BUILDING PERMIT DECLARATIONS I herebyaffirm under LICENSED CONTRACTOR'S DECLARATION penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code. and my Ucen is in full force and effect. � License Class_ i�L c�ense No. , ----bate I hereby affirm under penaltyof OWNER -BUILDER DECLARATION perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve. demolish. or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State Uoense Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however• the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date - Owner WORKERS' COMPENSATION DECLARATION '.I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 451-I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this ssue M wo a compensation i rance cam .er and policy number*are• permit is artier f 1 Piolicy Number —AA�,41 L 00-11'(0-00 I certify that,lin the performance of the work for which this permit is issued. I shall not employ an y person in any anner socompensation laws of California, and agree that, if I should become subject to the workers' compensation provisions o Saection to become37OO of the Labor Code shall forthwith comply with those provisions. /bate 1 D -I, plicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES D CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100;000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN AN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I herebyaffirm under CONSTRUCTION LENDING AGENCY penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address IMPORTANT APPLICANT ACKNOWLEDGEMENT ` Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this applir:abon. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any perftt issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this*application becomes null and void if work is not commenced within 180 dayt from date of issuance of such permit, or cessation of work for 18q days will subject permit to cancellation. I certify that I have read this application and state that the above information is cored. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. _,,-�Date mgnature (Applicant or Agent): Page 2 Application Number 04-00004489 Date 6/02/04 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9."0000-EA MECH,FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 2.00 6.5000 EA. MECH VENT FAN 13.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . ... . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 128.17, Plan Check Fee 8.01 Issue Date Valuation 0 Qty, Unit, Charge Per Extension BASE FEE'' 15.00 2990.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 104.65 426.00 .0200 ELEC GARAGE OR NON'-RESIDENTIAL 8.52 Permit . . . ... PLUMBING. --------------------------------- Additional desc Permit Fee . . 189.75 Plan Check Fee 11.86 Issue Date Valuation 0 Qty Unit Charge, Per Extension BASE .FEE 15.00 20.00 6:0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3..0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 7.00 .7500 EA PLB GAS PIPE >=5' 5.25 1.00, 15.0000 EA PLB GAS METER 15.00 Permit . . . . . . GRADING PERMIT Additional desc Permit Fee 15.00, Plan Check Fee .00 Issue Date Valuation 0 Qty Unit. Charge Per Extension BASE FEE 15.00: Special Notes and Comments SFD - LOT 83., PLAN 3Z. PERMIT DOES NOT Page 3 Application Number 04-00004489. Date 6/02/04 Special Notes and Comments INCLUDE BLOCK WALLS, POOL., SPA OR DRIVEWAY APPROACH. 75% PLAN CHECK FEE REDUCTION APPLIED.FOR MULTIPLE ISSUANCE OF SAME PLAN TYPE. Other Fees . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC -CENTER -.RES 366.00 ENERGY REVIEW FEE 15.11 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 'DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 18.25 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited_ Due Permit Fee Total 1333.42. .00 .00 1333.42 Plan Check Total 175.41 .00 .00 175.41 Other Fee Total 2438.36 - -.00 .00 2438.36 Grand Total 3947.19. .00` .00 3947.19 LA QUINTA �BUItLi1NG FETY DEPARTMENT OF CITY OF LA QUINTA 7 7-7012 FINANCE D_ �MPECTIC N REQUEST LINE ^ 777-7153 Owner LENNAR HOMES OF CALIFORNIA ContractorLENNAR HOMES OF CALIFORNIA Permit Number 04-4489 POST 'ON JOB INCONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS�-670VIA CATAI;INA l SFD — LOT 83 PLAN 3Z, PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. TYPE OF INSPECTION DATE INSP. TEMPORARY POWER SETBACKS U/G PLUMBING / WASTE U/G ELECTRICAL / GROUNDING FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE UNTIL AIJOES19 NE ROOF NAIL / PRE -ROOF OKAY TO WRAP - -� FRAMING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL INSULATION " 04 10 COVER NO WORK UNTIL ABPVF SIGNED INTERIOR GYP. BD. DRYWALL Q EXTERIOR LATH -O141.7 GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G GAS- U/G AS,U/G ELECTRICAL PRE -PLASTER (ALARMS/ BARRIERS FINAL INSPECTIONS TEMP. U6E OF PERMANENT POWERT)', i „ ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING 11/15/2004 20:37. 7605642044 DESERT ENERGY SERVIC r ENEIFIGYW.CADIEC • S P0. Box 621 PhTax (760) 5842044 Rancho MI oge. CA =70 CsIL (780] 250.1652 Email DESN G GAOLCOM PAGE 03 CERT[MCATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R LA QUANTA DEL ORO PH 3 1141W Project Title Date 44-670 r VIA CATATLI<NA LA QUINTA, CA. 92253 _LENNAR HOMES ro] O cASTENADA ��g�968 Builder Name .PLAN 3 2 UNITS Builder Contact Telephone Plan Number ALAN WEAVER 760580-6504 C+ Q11.P 2 HERS Rater Telephone Sample Group Number tOCCNAW183226 111 -IS -04 : 93-2 2 OF 2 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. CHEERS Street Address: P.O. BOX 621.' City/StaterLfp: .RANCHO MIRAGE, CA. 82970 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT', The house was: ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -6R (Installation Certificate, ® Distribution system is fully ducted(i.e:, does not use building cavities as plenums or platform returns in lieu of ducts) ® More doth backed, rubber adhesive duct tape is installed, mastic and drawbands are used In combination with cloth backed, rubber adhesive duct tape to seal leeks at duct connections.. ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION •COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct -Leakage) Measured Duct Pressurization Test Results (CFM 0 26 Pe) values - Test Leakage Flow in CFM so If fan flow is calculated as 400cfmlton x number of tons enter calculated value We 1400 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) 5.714 Check Box for Pass or Fail (Pass=6% or less) ® ❑ Pass Fail ® TKERM.W.CATIC EXPANSION VALVE (TXV) ® yes ❑ No Thermostaiic,Expansion Valve is installed and Access is provided for inspection ® ❑ SEP -02-2004 04:26 PM CDFA.RIFA'—PALM.DESERT 760'776'8091 P.02 r CooperativeRredllmporttdF'ire Amt PrOj®ct riati�ficatioa 011uteat taMGyaA6 4ftcrm or Within QUaraautined • �.�eag a£ Orsf�e, �tverslde, aad Las Angeles �E�ub,t�e� �LiA CampliaarQ A,grer�eae� �, �yjpg C��Ca��Y '• Ag4rx7 N=C of Coalpagy R�uatiag Appco�►e1 C;oq�ctPer+sa: 1r''J sr�e. " �71�7 275 Nom_ ems`!( F FPx:A-9 ...gcycpl�o'ac: _ Exct"(ianLoc1uo�L��/'��- Dradudaa Ldcetiao: ESdrettd QVLG�t� Ot �0U (G 4.e�( /✓ v �cipatcdDeu of bSovem�at � � G , 'UrpeocyL vdforImmeaiusYrspcetfAu en�FLele�sa: (Ciadt OAe� �� }�.cs�a u' . � y(oveo�eet of Soil isPcrr�t� HoSd Mo aeatLlanl Siw eked - K� �- Ca1.L AS SOON AS pOSSML-1 70 sammLE wspF crm a oATB Nm'� r DateTrappeos !s ai%,pay .TnT--Pot �..�.� SOU movewcat is 5tict 7ro�lblicd for dre Fot Q* -',r t Nene of RiFx Project Qtery 06ilei ` Sim - To o T% p.qm ut[ grid dnt�sd 9�a'd �5�••or� - S"IOOd-dINMO�I�a wd�:b s00�'rE'�nd Certificate of Insulation Your }come has bees insulated with CertainTeed Fiberglass Insulation products, which are designed for today's safety standards and tornorro),Vs energy requirements. Fiberglass is inorganic and therefore per.-nauently noncombustrole, so it docs not have to be treated H1th fisc -retardant chemicals that wdl likely lose their effectiveness over time. It Iris not been treated -D with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it settle over time as thay other insulation materials. - * ' This also certifies that CertainTeed Fiber Glass insulation bw boon professionally installed in this home _ to provide the following thermal performance; Job Name: La Quints Del Oro Tract: 30521 Phase: -3. Lot Ai.: 83 Plan: 3Z Address: 44-670 Nria Catalina, La Quinti, CA Roof Ceiling: ' . R-30 Blo,%Nn Or-erhangs: _ Knee V1'alls: Pam Walls R Exterior Walls: - [t 13 Unfaced Batts (2) Layers Casita Exterior: Garage Walk: Interior Walls Valls (Noted) SuB,c trio r . OJlnsu tion Co., Inc. i - _ 6U0. �`i en1, Ca 9I7 2 6070 Ltcenec t465709 " Signed 'Conchita Ortiz, Secretary/7'rerasurer —or R. Scott Jenkins, President or-- , i Lou Merola, Director of Operations Officer R- means resistance to heat flow. The higher the R- value, the greater the insulating power. Ask your builder for the 'fact sheet on R- values. Keep this certificate with your other valued papers. Nyou ever sell this home, this certificate should be passed on to the buyer. - T , S, , Z _ _ 11/15/2004 21:26 7605642044 DESERT ENERGY SERVIC Down ENERGY �� C A D E�C-L P0.6o« 621 Ph/Fax (780) 564.2044 Rancho Mirage, CA 92270 Cell: (7901250-1052 Email: D_eM.RG OL.COM PAGE 02 .1 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R LA QUINTA DEL ORO . PH 3 1142A4 Project Title Date 44-670 VIA CATATLINA LA QUINTA, CA. 92253 ro)e CHy s�CASTENADA l 70478-6968 Builder Name PLAN 3 2 UNITS Builder Contact Telephone Plan Number ALAN WEAVER 760.8804 SO4 - _GROUP 2 HERS Re%pd Telephone Sample G p roup Number OCCHAW193226 11 -15-04 83-2 1 OF 2 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. CHEERS Street Address: P.O. BOX 621 City/State/Zip: RANCHO MIRAGE, CA. 92270 Copies to: Builder, HERS Provider t HERS RATER COMPLIANCE STATEMENT The house was: ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification. I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution system is fully ducted(I.e., does not use building cavities as plenums or platform retums in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections_ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM s0 If fan flow Is calculated as 400cfm/ton x number of tons enter calculated �~ value here 1400 If fan flow is treasured enter measured value here Leakage Percentage. (100 x Test Leakage/Fan Flow) = 5.714 y. z Check Box for Pass or Fail (Pass=6% or less) ❑ Pass .Fail ® THERMOSTATIC EXPANSION VALVE (TXV) ® Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ® ❑ 11/15/2004 20:37 7605642044 DESERT ENERGY SERVIC PAGE 04 u Doti - ENERGY - Aa E ,. S P0. Bax 911 Ph/Fax (760) 564-2044 Rancho Mirage. CA 92270 Coll: (7601250-1852 Email: pLG_ &C 4tlA9J Q9A CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R LA DUINTA DEL ORO PH 3 Project Title Date -44-670 VIA CATATLINA LA QUINTA, CA. 92253 --LE 9 HQUES pro)d ress Builder Name WCASTENADA 760.678-6968 CASITA 1 UNITS Builder Contact Telephone Plan Number ALAN WEAVER 760.880•G.W _QAQUP 2 - HERS Rater Telephone Sample Gmup Number t#CCHAW189226 1145.4M 83-2 1 OF I Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. CHEERS Street Address: P.O. BOX 621 City/Stster ip: RANCHO MIRAGE, CA. 82270 Copies to: Builder. HERS Provider HERS RATER COMPLIANCE, STATEMENT The house was: ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -61R (Installation Certificate. ® Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed,mastic and drawbonds are used in combination with doth backed, rubber adhesive duct tape to seal Ieaks at duct connections, ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Dud Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM 1S if fan flow Is calculated as 400cfm1lon x number of tons enter calculated value here 800 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) _ 2,25 Check Box for Pass or Fail (Pass=6% or less) ® ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TX V) ® Yes ❑ No Thermostatic Expansion Valvc is installed and Access is provided for inspection - ® ❑ 11/15/2004 20:37 7605642044 DESERT ENERGY SERVIC PAGE 02 Damn ENERGY CABER S P0. Box 821 Ph/Fax (760) Se4-2044 Rancho Mirage, CA 92270. Cell: (760) 250-1852 Email: QF.ANRG RAOL.COM CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -411R LA CAJINTA DEL ORO' PN 3 1o1u Project Title Date 44-670 VIA CATATLINA LA QUINTA, CA. 92253 LIENNAR HOMES raiN ASTENADA 760.678.6968 Builder Name PLAN 3 2 UNI'T'S Builder Contact Telephone Plan.Number ALAN WEAVER 780- 604 - C, 2 HERS Rater , Telephone Sample Group Number t #CCNAW183226 11-15--04 - 83-2 1 OF 2 Certifying Signature -Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. CHEERS Street Address: P.O. BOX 621 City/State/Zip. RANCHO MIRAGE, CA. 52270 Copies to; Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was. ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic besting and field verifications I certify that tate houses Identified on this form comply with the diagnostic tested compliance requirements as checked on Ws form. ® The installer has provided a copy of CF -813 (Installation Certificate: ® Distribution system is fully dueted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed, mastle and drowbands are used in combination with cloth backed, rubber adhesive duct tape to seat leaks at duct connections. ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) y Measured Duct Pressurization Test Results (CFM @ 25 N)" values Test Leakage Flow in CFM 71 If tan flow is calculated as 400cfmftn x number of tons enter calculated value here 2200 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = 5.9167 Check Box for Pass or Fail (Pan -6% or less) ® ❑ Pass Fail ® TT -M MOSTATIC EXPANSION VALVE (TXV) to Yes ❑ No Thermostatic Expansion Valve is installed and Access is ® ❑ provided for inspection 11/15/2004 21:26 7605642044 DESERT ENERGY SERVIC Down ENERGY C A o E P0. 8px 021 PA/Fax. (780) 564-2044 Rancho Mhage, k;A 82270 -Coll: (760) - EmL ail: DESNRG ®AOCOM PAGE 03 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R LA QUINTA DEL ORO PH 3 Project Title Date 44-670 VIA CATATLINA LA QUINTA, CA. 92253 ro)LENMAIR HOMES N CASTE����� NADA Builder Name t7 PLAN 3 2 UNffS Builder Contact Telephone Plan Number ALAN WEAVER 7®0.8804504 SzR9UP 2 HERS Telephone Sample Group Number OCCNAVIMS 6 1145--04 .93-2 2 OF 2 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. CHEERS Street Address: P.O. BOX 621 City/5tateeip: RANCHO MIRAGE, CA. 82270 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: ® Tested ❑ ' Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I Certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form, ® The installer has provided a Copy of CF -6R (Installation Certificate, ~ ® Distribution system is fully ducted(i.e_, does not use building cavities as plenums or platform relums in lieu of ducts) ® Where doth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seat leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Dud Measured Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM 71 If fan flow is calculated as 400cfm/tcn x number Of tons enter calculated value here 1200 If fan flow is measured enter measured value here _ .Leakage Percentage (100 x Test Leakage/FanFlow) = S-9667 Check Box for Pass or Fail (Pass -e6% or less) ❑ ❑ Pass Fail ® THERMOSTATIC EXPANSION VALVE (TXV) ® yes ❑ No Thermostatic Expansion Valve is installed and Access is .provided for inspection ❑ 11/15/2004 21:24 7605642044 DESERT ENERGY SERVIC PAGE 02 CA1pEC ENERGY ' . S _ Po. Box bat Ph/Fax (760) 564-2044 Rancho Mirage. CA 9=70 Coll: (7601260 1962 Email: Rmftq �ACiL.COM CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page.1 of 7) CF -4R LA CUINTA DEL ORO PH 3 bate Project Title 44-670 VIA CATATLINA LA QUINTA, CA. 92253' _LEdNAKM Builder Name "J N H31ASTENADA 760.678.6968 CASITA I UNITS Builder Contact Telephone Plait Number ALAN WEAVER 7MU0 ' . GRQUP _ HE terTelephone Sample Group Number #CCNAW163226 - 11-115-04 83-2 1 OF 1 Ce;iWing Signature Date Sample Lot Number Firm: DESERT ENERGIE SEFMCES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 City/State2p. RANCHO MIRAGE, CA. 92270 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) N Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.- . . ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results .(Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM ® 25 Pa) ' values Test Leakage Flow in CFM IS If fan flow Is calculated as 4000mRon x number of tons enter calculated value here. Sal if fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakagv?an Flow) 215 ® ❑ Check Box for Puss or Fail (Pass -6% Or less) Pass Fail ® TRERMOSTATIC EXPANSION VALVE (TXV) ® Yes ❑ No Thermostatic Expansion Valve is installed and Access is ® ❑ provided for inspection 11/15/2004 21:24 7605642044 DESERT ENERGY SERVIC PAGE 03 Dmoft— cAeEC EOLI e . S PWFax (780) 564.2044 P0. Box 621. CeU: (7601260-1e62 Rancho Mira9 . CA 90'12 Email: QFsr .. , CF -4R CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) LA OUINTA DEL ORO PH 3 - Date Project Title CA. 9tZ53 44-670 VIA CATATIIN.A LA UINTA; Builder Name role C ASTENADA 7604S78-6968 PLAN 3 2 UNITS Builder Contact Telephone Plan Number ALAN WEAVER 76�D'� JROl1P 2—. HERS Ra;o , Telephone . Sample Group Number "1 #CCNAW183226 11.15-04 83-2 t OF 2 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider. 'CHEERS Street Address: P.O. BOX 621 - City/Stateop: RANCHO MIRAGE. CA, 9WO Copies to: Builder. HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: M Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses Identifled on this form comply with the diagnostic tested compliance requirements or, checked on this form, ® The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution sys0am is fully duded(te., does not use building cavities as plenums or Platform returns in lieu of duds) ® Where cloth backed, rubber adhesive duct tape is Installed, mastic and dmwbands are used In combination with cloth backed. rubber adhesive duct tape to seal leaks at duct "connections. ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM 80 If tan flow is calculated as 4000IM ton x number of tons enter calculated value here .l� 400 If (an flow is measumd enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = 5.714 ® ❑ Check Box for Pass or Fail (Pass=6% ar less) Pass Fail THERMOSTATIC EXPANSION VALVE"(TXV) ® Yes ❑ No Thermostatic Expansion Valve is installed and Access is 9 ❑ provided for inspection S outhwestInspection and Testing, Inc. (1 �- b 10826 South Norwalk Blvd., Santa Fe Springs, CA 90670 4) 526-8441 - Fax (562) 946-0026 L- REGISTERED INSI ORS S DAILY TYPE OF Reinforced Concrete INSPECTION . ❑ Post Tensioned Concrete REQUIRED ❑ Reinforced Masonry --------------- Job Address FiobName f Structureol Description (tie, grc Inspector(s) TYPE OF SAMPLE ,,, "/ % b-/ is - r i SLUMP DDT ❑ Structural Steel Assembly ❑ Fire Proofing ❑ Asphalt City Permit No. Issued By Architect Engineer F Q 1 Contractor t+ I Subcontractor r TESTS PERFORMED QUANTITY IN SET e- 11 I ❑ Quality Control ❑ Other ADDITIONAL REMARKS ON SAMPLES gMal INSPECTION SUMMARY — LOCATIONS OF WORK INSPECTED, MO NTS OF MATERIAL PLACED OR WAMPLES TAKEN, WORK R ORK PERFORMED, ORMED, NUMBER, TYPE & IIbENTPROBLEMS, PROGRESS, R NO'S OF INCLUDES INFORMATION ABOUT CTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC. TEST SAMPLES TAKEN: STRUCT. CONNE q D 9 I - , vF 7 r `fG 17 '7e < �°_ t 27 7`F `- - ,.,20A q/GC i.C� 0`5y CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS, AND APPLICABLE SECTIONS OF HE GOVERNING BUILDING LAWS. J„ SIGNATURE OF RE ISTERED NSP fj d�0. r CONTINUED ON NEXT PAGE ❑ PAGE OF TIME IN TIME OUT REG. HbURS O.T. HOURS CYLINDERS �0 ?0� All inspectio based on a mi imum of 4 hours and over 4 hours - hour minimum. In dition, any in ectio extending past noon hour will be an 8 hour minimu r Approved by / . Project Superintendent SOECIALTY NO. AGENCY WHITE OFFICE COPY, CANARY- ACCOUNTING COPY, PINK INSPECTOR'S COPY, GOLDENROD .10B SITE COPY