Loading...
12-1195 (RPL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12-00 0 0119 5 Property Address: - 44715 VIA CATALINA APN: 604-032-999-81 -305212- Application description: POOL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 30000 T,&t °F 4 Q" Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT .. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — LICENSED CONTRACTOR'S DECLARATION . I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C36 C53 —}—� License No.: 618116 Date: 10 Zb IL tractor: 1 1`1� L� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt om the Contractor's State License Law for the - following reason (Sec. 7031 .5, Business and Professions ode: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) -of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by , any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:' (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The t Contractors' State License Law does not apply to an owner of property who builds or improves thereon, _ and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address:�rT \\ LQPERMIT Owner: ERIC WADLUND 44715 VIA CATALINA LA QUINTA, CA LA QUINTA, CA 92253 Contractor: LEAK DETECTORS P:O. BOX 7.27 THOUSAND PALMS, CA (760)773-9070 Lic. No.: 618116 VOICE (760) -701 FAX (760) 777- 11 INSPECTIONS (760) 777-7153 D° OCT 2 6.2092 CITY OF LA QUINTA FINANCE DEPT. 92276 Date: 10/26/12. s WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: . I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the1abor Code, for the performance of the work for which this permit is " issued. . `' I have and will maintain workers'. compensation insurance, as required by Section 3700 of, the Labor ' Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier EVEREST NATL Policy Number 7600009413121 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section , 700 of the Labor Code,, I�shaalll forthwith comply with those provisions. Yate: 0!� �Z A scant: J V \/ v v yam.% lM�i b!✓� /WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND _ DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.. APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for - whose benefit work is performed under or pursuant to any permit issued as a result of this application, the.owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City ' of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I ` I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this �fty t enter upon the above-mentioned property for inspection purpos ate: Ib (�6 IZ S ature (Applicant or Agent): I Y. Application Number 12-00001195 Permit . . . BLDG POOL PERMIT Additional desc.. Permit Fee . . . . 2.84.50 Plan Check Fee 184.93 Issue Date . . . . Valuation . . 30000 Expiration Date 4/24/13 Qty Unit Charge Per Extension BASE FEE 252.00 5.00 6.5000 THOU BLDG 25,001-50,000 32.50 ° Permit MECH POOL Additional desc . Permit Fee 26.00 Plan Check Fee 6.50 Issue Date . . Valuation . . 0 Expiration Date 4/24/13 Qty Unit Charge Per Extension �y BASE FEE 1,.00 • 11 . 0000: EA MECH FURNACE '>100K _ 11.00 Permit ELEC POOL.PERMIT-RES, Additional desc . Permit Fee • ; 45.00, 'Plan Check Fee +. 11.25. Issue Date Valuation- 0 ' 'Expiration Date 4/24/13 - Qty Unit Charge Per Extension BASE FEE 15.00 1.00 30.0000 EA f ELEC PRIVATE SWIMMING POOL 30.00 --- ------ -. -- - - - - -- ----- - - - - -- f • --- --------.. • Permit PLUMBING t•.., .- Additional desc ". + ..Permit Fee •. . . . . 33.00 Plan Check Fee 8.25 Issue Date . . . . Valuation . . _ 0 Expiration Date 4/24/13 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA ^. PLB FIXTURE 12.00 1.00 3.0000 EA PLB WATER INST-/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 Permit .. . . .WALL/FENCE.PERMIT LQPERMIT ' Application Number . . . . . 12-00001195 Permit . .' WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue "Date . . . . Valuation 128 Expiration Date 4/24/13 Qty Unit Charge Per Extension BASE FEE 15.00 •Special Notes and Comments POOL/SPA, 8 L.F. 4' EQUIPMENT ENCLOSURE, CITY STANDARD.. INCLUDES 125 L.F. 2" GAS LINE. ALARMS/BARRIERS SHALL BE IN PLACE AT PRE -PLASTER INSPECTION. 2010 CODES. --------------------------------------- ----------------------------- Other Fees BLDG STDS ADMIN (SB1473) 2.00 Fee summary Charged, - Paid Credited Due --------------- Permit Fee Total 403.50-',.,. 00 .00 403.50 y r Plan Check Total 210':93 00 .00 210.93 ` - 'Other Fee Total 2.00 :00 .00 2.00 Grand Total. _ ; 616.43 00 .00 •616'.43 _. LQPERMIT .. .. The Management Trust MONARCH GROUP DIVISION October 24, 2012 ERIC & ROWENA WADLUND 44-715 VIA CATALINA ' LA QUINTA, CA 92253 . RE: Architectural Submittal for 44-715 VIA'CATALINA Account #747062 Dear Homeowner: The Architectural Review Committee for LA QUINTA DEL ORO has reviewed and APPROVED your architectural submittal for the installation of pool and spa, per the new plans submitted with the correct drainage. All construction must commence within 120 days of this approval letter. If construction has not been commenced within the 120 days, such approval shall be deemed withdrawn. ARC approval of plans shall not constitute, a representation, warranty, or guarantee that such plans and specifications comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans and specifications, neither the ARC, the Members thereof, .the Association, any Member thereof, their Board of Directors, any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in the construction or improvement from such plans or specifications. As provided in the CC&R's neither the ARC, the Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice s uffered or claimed on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not defective, or (2) the construction or performance of any work whether or not pursuant to the approved plans, drawings, or specifications. ` Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please contact the association at (760) 776-5100, Extension 333. Sincerely, r On behalf of the,LA QUINTA DEL ORO Architectural Review Committee Heather Yslas Association Assistant Manager Jamie Hansen ` The Management Trust - Monarch Group Division Enclosures (1). ' cc: Board of Directors - Unit File ` 39755 Berkey Drive, Suite A, Palm Desert, CA 92211 CONNECnNGPEOPLETOTHEPROI PH: 760.776.5100 FAX: 760.776.5111 www. m a n a g e m e nttru st. co m i i W Bin. # i ...: City of Quinta .La r. -Building 8L Safety Division �- Permit # P.O. Box 1504,78-495 Calle Tampico I La.Quinta, GA 92253 - (760) 777-7012 Building Permit-ApPlication'and Tracking Sheet jProject Address: 7157 Vi 'Owner s Name:. L -0'L U N 0 A P. Number. Address: q 7 I S I (� td Legal Description: City, ST, Zip: jo Contractor: 7W Umv, _ t:c R.S Telephon Address: BD 7 Z t Project Description:�r— City, ST, Zip:0tw's&7W CIO I i —ca. """'M Telephon % % 3 ' "za u \ , f:, ,�,: 7M- COAC' DeL4ci iN ~` // State Lie. # : $ (Its City Lie. # g�Ot=t r Arch., Engr., Designer -W., j j Address: 771z87 O-N �= tv o City, ST, Zip: N�S -IV 1.30 Telephone: "� y Y- Construction Type: , Occupancy: State Lie. M 33 q y6 w u d Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: L-V ' Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: % 60 ;z72— I Z O (v Estimated Value of Project: �303dpoo APPLICANT: DO NOT WRITE BELOWi THIS UNE ' # Submittal Req'd Rec'dTRACHING PERMIT FEES Plan Sets Plan Check submitted " Item Amount s i Structuiai Ca[es. Reviewed, ready for corrections Plan Check Deposit, Truss C21cs• Called Contact Person Plan Check Balance Tide 24 Cates. Plans picked up Construction Flood plain plea_ -Plans-resubmitted-' — -Mechanical -- - Grading plan Review, ready for correctionsfissue Electrical - --- Subeontaetor List — - - -- -- Called Contact Person Plumbing — — - -- Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review; ready for correctionsAssue Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. • Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees INSTALLATION CERTIFICATE CF-6R-MECH-03 Pool And Spa Heating Systems — (Page 1 of 2 Site Add rest: Y71 Enforcement Agency: Permit Number: Pool and Spa Heating Systems requirements §I14(a): Systems and Equipment. . ❑ 1. Heater has a thermal efficiency that complies with the Appliance Efficiency Regulations. ❑ 2. Has a readily accessible on-off switch mounted outside of the heater. ❑ 3. Weatherproof plate or card containing operating instructions for the pool or spa heater. ❑ 4. No electric resistance heating except for listed package units that has fully insulated enclosures and tight fitting covers that are insulated to at least R-6. Or if documentation is provided that at least 60 % of the annual heating energy is from site solar energy or recovered energy. ❑ 5. Heating system has no pilot light. § 114(b): `Installation. - t ❑ 1. System is installed with at least 36" of pipe between the filter and heater, or dedicated suction and return lines, or built-in or built-up connections for future solar heating. ' ❑ 2. A cover for outdoor pools or spas that have a heat pump or gas heater. ❑ 3. Pool system has directional inlets to adequately mix the pool water ❑ 4. Time switch which will allow the pump to beset or programmed to run during off-peak periods only 1150(p) 150(p) Pump Sizing and flow rate specification ❑ l . The pump specified is listed in the CEC database of certified pool pumps. ❑ 2. The pump flow rate shall be calculated based on pool sizing table below: ❑ 3. The pump is capable of operating at 2 or more speeds (not applicable if pump is less than l horsepower). ❑ 4. Each auxiliary pool load is served by either a separate pump, or the system is served by a multi -speed pump. Pool sizing alues are based on a maximum allowable turnover rate ot6- hours + Max Pool. Volume (gallons)inches(sqare Min Pipe D or Greater Min Filter Area or more feet Max Pump Flow m Retum Suction Cartridge Sand DE 13,000 1.5 1.5 100 2.4 20 36 17,000 1.5 2 130 3.1. 25 47 21,000 2 2 160 3.9 30 58 28 000 2 2.5 .210 S.2 40 78 42 000 2.5 3 320 7.8 60 _ 117 48,000 3 3 360 8.9, ... 70 133 Note: For. pumps greater than I hp. The maximum Pump Flow is the lowest speed default filtration ❑ 5. Calculated volume of ool_ ) 5 SO O P i (gallons). ' . 6. Return Pi i i. 13a Diameter, P ' Z (inches). • ❑ 7. Suction Pipe Diameter . Z �. (inches). 138. Filter Type ��$(��"�_ t: (Cartridge, Sand, DE).' ❑ 9. Filter Surface Area i{2� (sf), - ❑ 10. Max Pump Flow 3 S (gPm)• 2008 Residential Compliance Forms August 2009 INSTALLATION CERTIFICATE CF-6R-MECH-03 Pool And Spa Heating Systems (Page 2 of 2 Site Address: Enforcement Agency: Permit Number: System Piping ❑ 1. The suction side pipe is straight for at least 4 pipe diameters before entering the pump (See table below for the required straight run lengths for various pipe sizes). ❑ 2. The design uses low pressure drop fittings (sweep90's) Pipe Diameter inch . Required Pipe Length leading into pump (inch) 1.5 6 2 g 2.5 10 3 12 Filtration Equipment ❑ 1. If a backwash valve is used: The diameter of the backwash multi -port valve is 2 inches or as large as the circulation pipe, whichever is greater DECLARATION STATEMENT • 1 certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • 1 certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. • 1 reviewed a copy of the Certificate of Compliance (CF -111) form approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed bn the CF -1R that apply to the installation have been met. • I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. 2008 Residential Compliance Forms August 2009