Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
07-0744 (SFD)
Q.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: . Applicant: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 00000744' 53075 VIA—CHIANTE 772-550-010- - - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENT -IAL 499336 a VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/18/07 Owner: BLAKE SSCHWATZMAN , 3033 RIKKNS DRIVE WESTLAKE VILLAGE, CA 91362 Contractor: Architect or Engineer: HAMERCOP- HOMES INC 3033 RIKKARD DRIVE WESTLAKE VILLAGE; CA 9136 (818)309-3765 t!f,i Lic. No. 791562. - OP 4 LQPERMIT . LICENSED CO ACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION ' I hereby affirm under penalty of perjury that I am lice under provisions of Chapter 9 (commencing with • I hereby affirm under penalty of perjury one of the following declarations: .. , Section 7000) of Division.3 of the Business and PIdWionals Code, and my License is in full force and effect. - I have and will maintain a certificate of consent to self -insure for workers' compensation, as. provided - • License Class: B Lice : 791562 - _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is 1{7 ate: i1 l/ ractor: 1' issued. ly I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ' Code,. for the performance of the work for which this permit is issued. My workers' compensation NER-BUILDER DECLARATION �thatl-i - insurance carrier and policy number are: -1 hereby affirm under penalty of perempt from. the Contractor's State License Law for the Carrier. STATE FUND y Number 1849788 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the peork for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manne subject to the workers' compensation laws of California, , permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I bject to the. workers' compensation provisions of Section License Law (Chapter 9Icommencing with Section 7000) of Division 3 of the Business and Professions Code) or - 4esubject 3700 of the Labor ith comply with those provisions.that he or she isexempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by/any �d applicant for a permit. subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ate pplicant:1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SEC ENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, "SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN ' - improvements are not intended or.offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. y - one year of completion, the owner -builder will have the burden of proving that he or she did norbuild or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT • 1 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the _ . 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for - pursuant to the Contractors' State License Law.). - ,' whose benefit work is performed under or pursuant to any permit issued as a result of this application, • (_ 1 I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City a of La Quinta, its officers, agents and employees for any act or omission related to the work being. 1 performed under or following issuance of this permit. _ Date: Owner: - 2. Any permit issued as a result of this application becomes null and void if work is not commenced . within 180 days from date of issuance of such permit, or;essa ' of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above info atioq�is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.1. '-city and county ordinances and state laws relating to building con uctio ,and hereby authorize representatives - . . of this county to enter up t above-mentioned property for ' pecti urposes. Lender's Name: _ / S' ature (Applicant or Agent): Lender's Address: LQPERMIT . Application Number 07-00000744, Permit BUILDING PERMIT Additional desc . Permit Fee . . - . 2039.50 Plan:Check Fee1325.68 Issue Date Valuation . . . . . 499336' Expiration Date 12/15/07 Qty Unit Charge Per' Extension BASE FEE' 639.50 400:00 3.5000 ----------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1400.00 - Permit . . . MECHANICAL' - Additional desc Permit Fee 139.00 Plan Check Fee 34.75 Issue Date Valuation . . . . 0 'Expiration Date 12/15/07 Qty .Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36:00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 7.00 6.5000 EA MECH VENT FAN 45:50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee_ -248.96 Plan Check Fee 62.24 Issue Date Valuation . . 0 Expiration Date 12/1.5/07. Qty Unit Charge Per Extension BASE FEE 15.00: 5820.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 203.70 763.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 15.26 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit PLUMBING . Additional desc . Permit Fee . . 276.00 Plan Check Fee 69.00 Issue Date . . . Valuation 0 Expiration Date 12/15/07 Qty Unit Charge Per Extension 'BASE FEE 15.00 28.00 6.0000 EA PLB FIXTURE 168.00 LQPERMIT - - Li Ilk Application Number . . . . . 07-00000744 Permit . .. . . PLUMBING Qty Unit Charge Per Extension 1.00 15.0000 EA PLB BUILDING SEWER 15.00 4.00 6.0000 EA PLB ROOF DRAIN 24.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA' PLB LAWN SPRINKLER SYSTEM 9.00. 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00. Permit . . . GRADING.PERMIT Additional desc . Permit Fee .. 15.00 Plan Check Fee .00" Issue Date . . . . Valuation . . 0 Expiration Date 12/15/07 - .Qty Unit Charge Per Extension 15.00 ----------------BASE -FEE.--------------------- Special Notes and, Comments ------- 5820 sq. ft.•sfd this permit does -not include pool &'spa block walls or driveway approach.June"18, 2007 1:33:06 PM jjohnson ------------------------------------------------- Other Fees ---------------- ART IN PUBLIC PLACES -RES 748.34 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 132.57 DIF FIRE PROTECTION -RES. 140.00 GRADING PLAN CHECK FEE, ° 15.00 DIF LIBRARIES -'RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC.- RES 892.00 STRONG.MOTION (SMI) - RES`- 49.93 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due Permit- Fee Total ----- ---------- ---------- 2718.46 .00 .00 2718.46 Plan Check Total" 1491.67 500.00 .00 991.67 Other Fee Total 5420.84 .00 .00 5420:84 Grand.Total 9630.97 500.00 .00 9130.97 LQPERMIT _ - P.O. BOX 1504 T44t 4 �w 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00000744 Owner: Property Address: 53075 VIA CHIANTE BLAKE SSCHWATZMAN APN: 772-550-010- - - 3033 RIKKNS DRIVE Application description: DWELLING - SINGLE FAMILY DETACHED WESTLAKE VILLAGE, CA 91362 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 499336 D Contractor: Applicant: Architect or Engineer: STARR III CONSTRUCTION 1216 CALLE ARROYO THOUSAND OAKS, CA 91360 (818)309-3765 Lic. No.: OOR SQUARE FOOT Lic. No.: 570496 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 570496 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/06/09 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier SCIF SAN DIEGO Policy Number 00000043202 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Anypermitissued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Application Number . . . . . 07-00000744 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 2039.50 Plan Check Fee 1325.68 Issue Date 6/19/07 Valuation . . . . 499336 Expiration Date 4/26/09 Qty Unit Charge Per Extension BASE FEE 639.50 400.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1400.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 248.96 Plan Check Fee 62.24 Issue Date . . . . 6/19/07 Valuation . . . . 0 Expiration Date 4/26/09 Qty Unit Charge Per Extension BASE FEE 15.00 5820.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 203.70 763.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 15.26 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . 6/19/07 Valuation . . . . 0 Expiration Date 4/26/09 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 139.00 Plan Check Fee 34.75 Issue Date . . . 6/19/07 Valuation . . . . 0 Expiration Date 4/26/09 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 LQPERMIT Application Number . . . . . 07-00000744 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 276.00 Plan Check Fee 69.00 Issue Date . . . . 6/19/07 Valuation . . . . 0 Expiration Date . . 4/26/09 Qty Unit Charge Per Extension BASE FEE 15.00 28.00 6.0000 EA PLB FIXTURE 168.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 4.00 6.0000 EA PLB ROOF DRAIN 24.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Special Notes and Comments 5820 sq. ft. sfd this permit does not include pool & spa block walls or driveway approach.June 18, 2007 1:33:06 PM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 748.34 CHANGE OF CONTRACTOR 4.50 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 132.57 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 HOURLY PLAN CHECK 70.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 49.93 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 2718.46 ------------------------------ 2718.46 .00 .00 Plan Check Total 1491.67 1491.67 .00 .00 Other Fee Total 5495.34 5495.34 .00 .00 Grand Total 9705.47 9705.47 .00 .00 LQPERMIT ^` aa_,APrP.O. BOX 1504 �C( APPLI A��70 LYOBuldins78-495 CALLE TAMPICO Address t QUINTA, CALIFORNIA 92253 Mailing (� Address -303a (LKV�� OZip Tel. l�ivEfcvd' �� - �. I1 -Ip 1136 Z_ �7ci5 State Lic. & Classif. 7166-1. �`Ei'cty . # Arch., Engr., 1 Designer NA CA, cf- ( C`Gln��cc�l-1 cif N "U✓ y L Z I Lic. # ,SED CONTRACTOR'S DECLARATION I hereby affirm t I censed under provisions of Chapter 9 (commencing with Section 000) of Divisio of us, and Professions Code, and may license is in full force and ffar•.f i OWNER -BUILDER DECLARATION I y affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation o/ Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the pe it is /or one hundred d ars (5100) valuation or less). I certify that in the performance oft k for w ' this permit is issued, I shall not employ any person in any manner so as co k. s act to Workers' Compensation Laws of Calif Date q�aner NOTIC TO APPLICANT., If, altering this Certificate of Exemption you should become subject to the Workers' Compen ation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinancesand state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date . Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCP. P. C. GRl A.Number C./ LC, �—'� / b (? % 2 "4_50 -010 J Legal Description_ Project Description 4), Sq. Ft. Size No. No. Dw. Stories 2, Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ � 5 l -3o9- 3,7 6S Estimated Valuation PERMIT Ll AMOU Plan Chk. Dep. - Plan Chk. Bal. Const. Mech. Electrical Plumbing_ S.M.I. Grading 11 ' nn 711 Driveway Enc. Infrastructure ., _111111 ""'Am .I. 6 LUM ILVi 9 9 —s—...�.. F9NA• � � i - fail 4� TOTAL REMARKS V ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE_ Issued by: Validated by:_ Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Coachella Valley Unified School District This Box For District use only 83-733 Avenue 55; Thermal, CA 92274 DEVELOPER FEES -PAID (760) 3981-5909 - Fax (760) 398-1224 ' AREA: .AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: - RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education.Code 17620) Project Name: Hideaway/Schwatzman/Heisser Date: 06/18/07 Owner's Name:. Hideaway/Schwatzman/Heisser Phone No. - 818-309-3765 Project Address:. 53-075 Via Chante Project Description: 1 SFD APN: . 772-550-010 Tract #: Lot # L Type of Development: Residential kx" - Commercial Total Square Feet of Building Area: 5820 sq. ft. Certification of Applicant/Owners: The person signing certifies that the o e information is correct and makes this statement under. penalty of perjury and further represents that he/she is authorized to si on,behalf of the owner/developer. Dated: 06/18/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995, Approval , Prior to 1/1/87 Requirement Number of Sq.Ft. 5820 sq ft Amount per Sq.Ft. $ 3.91 per sq. ft. Amount Collected $ 22,756.20 By: Carey M. Carlson, Asst. Supt., Business .Services Certificate issued by: Maria L. Angulo, Facilities Secretary' Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATE NT OF FE Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions (.Tees"% of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees., Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole. or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted onlyfor good cause, as determined by the School District, and up to three (3) such extensions may, be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. Ll':c/mydoes/devfees/certificate of compliance form tablesTO USE.doc ' . 1/16/03 T 03/06/2007 11:36 FAX 7 818879069 BTI CHEMICAL I�J003 ..� • ,. •._.�-.:�; :; Vit;$: i .-ti �;� �:�°• RECORDING REQUESTED BY h ,n� :•:: DOC # 2006'0261-1-7& FI1 S T AMERICAN TITLE C4. 04/12/2006 08.ON Fim:13.00 MANN! i RiUERSID REST E Pas 1 of 3 Doe T .tax Paid Recorded in Official Records _ +}^�.. r Co4mty of Riverside ,i3,"^.•;:_� ;.:,~ 1 _ `0 AND WHEN RECORDED MAIL TO: Larry W. Yard Assessor, County Clark b Recorder Chris Heisser or Assignee �: :`:���: =- • i IIIIIIIIIIIilllilllll�IIIIIiIIlNIIIIIIIIl�IIII�IIII• -��h , • i A P N • 777-210-010-5 GRANT DEED The Undersigned Grantors) Dedare(s): DOCUMEWfARY TRANSFER TAX $75&75,.CITY TRANSFER TAX $0=; X computed on the consderation cr fuU value of propaty , OR ] computed on the consideration or full value lem value of 1m and/or enoun>WWWO remair►ing at tlrtre of sale, SR urano Waged area; [ X ) City of La Quints, and i FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Ridlard L COINn and ]anise i M. Corbin Revocable Trust, dated October 2, 2002 hereby GRANTS to Blake B. Sebwartzman a z»asried man . l the following described property in tete City of U Qulntk County of Riverside, State of California: Legal description as per Exhibit "A" attached hereto and made a part hereof. Dated: 03106/2006 „ - Mall TXx Statements To: SAME AS ABOVE i WIN- MANN! GRANT DEED The Undersigned Grantors) Dedare(s): DOCUMEWfARY TRANSFER TAX $75&75,.CITY TRANSFER TAX $0=; X computed on the consderation cr fuU value of propaty , OR ] computed on the consideration or full value lem value of 1m and/or enoun>WWWO remair►ing at tlrtre of sale, SR urano Waged area; [ X ) City of La Quints, and i FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Ridlard L COINn and ]anise i M. Corbin Revocable Trust, dated October 2, 2002 hereby GRANTS to Blake B. Sebwartzman a z»asried man . l the following described property in tete City of U Qulntk County of Riverside, State of California: Legal description as per Exhibit "A" attached hereto and made a part hereof. Dated: 03106/2006 „ - Mall TXx Statements To: SAME AS ABOVE i 03/06/2007 11:36 FAX 8188790697 BTI CHEMICAL -- - Q004 . .' .;'r,:!_.^.•.: ,.:: '?%'•'?;d;•;`,�`� ;•;,: mak:•: A.P.N.: T77-210-qi0-3 Grant Deed - continued File No.:RPD-2291305:=; Date: 03/06/2006 Richard L. Corbin and Janice M. Corbin Rev ble Trust , S �iZ Richard L. CorbinTrust//ee _ ni M. Corbin, Trustee STATE OF t i s )SS COUNTY OF On ► G before me, ,.�[j� r�St Notary Public, personally ap r�Ilt L,G Q, lLrb� n .mac (or proved to me on the basis of satisfactory evidence) to be the person(s) whose names) Kam subscribed to ,the within instrument and acknowledged W me that hakWthey executed the same in Hsow/their authorized capacity(ies) and that by hisA'/their signature(s) on the instrument the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. DJOHN101 C,omr'nstlon i 1467577 Signature NyG+ortnwE ssMAW My Commission Expires: � . cT DLA This arty for ol�iaal rtotaria/seal . Notary Name: Notary Phone: Notary Registration Number- County of Principal Place of Business: 03/06/2007 11:36 FAX 8188790697 BTI CHEMICAL 005 i i Exhibit "A" Real property in the City of La Quinta, County of Riverside, State of California, described as follows: j PARCEL 1: LOT 196 OF AMENDED TRACT NO. 29894-2, IN THE QTY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGE(S) 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND, PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. APN: 777-210-010-5 Title Order NuMW.f Ale Nwnber: RPD -2291105 ; Mr. and Mrs. Chris Heisser, 3033 Rikkard Drive Thousand Oaks, CA 91362 RE: Schwartzman /Final Design Review Lot 196 at 53075 Via Chiante Dear Mr. and Mrs. Heisser; Thank you for your attendance yesterday at the Hideaway Design Review Committee meeting. Your response comments and new plans were accepted by the Committee for review. The project was conditionally approved for you to begin construction. All of the items from our letter dated April 9, 2007 will need to be resolved prior to the setback inspection, please see the attached letter. The following items were discussed with you yesterday and will need to be incorporated into your next • submittal of plans: 1. The side yard balcony will need to be screened with two 48" box California Pepper trees. 2. The proposed lamps to be used as the exterior wall mounted fixtures were not approved for use because they have 4 lamps per fixture which would exceed the Hideaway requirements of 25 watts or less per fixture. Less candle power will need to be used. 3. The plans will need to be resubmitted to show the 1.0" thick walls, not 6". 4. The garage door as submitted was approved for use. 5. Structural header will be required, not a "plant on 6. A variance is required to have the pool at 5' from the property line. We have a variance request on file, but it is not for the location of the pool: Any deviation from the Design Guidelines must be submitted with a request for a Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process, it will be the design team's responsibility to make modifications at a later date if required by the Design Review Committee. Please contact Mindy Gutierrez at (760) 391-5211 with any questions. Sincerely, Hideaway Design Review Committee cc: Mr. Heisser at Chrisheisserhh@aol.com DRC File • Thank you!• This Material Sent for•: „ ❑ • Your Files Per Your Request ❑ Your Review ❑ *Approval ❑ Checking ❑,. At the request of: Other: ❑ < By. Palm Desert Office ❑ # (76) 360-5770 Washington Office: ❑ # (760) 404-9556 J Letter of Transmittal " To: City of La Quints t Today's Date: j 30 kto 78-495 Calle Tampico City,Due Date v3 La Quinta, Ca 92253 Project Address: Attn: Plan Check #: ` - Submittal: rte, tst ❑ 4th 'F❑' f 2nd ❑ 5th . r, •. ❑ 3`d ❑' Other: We are forwarding: By Messenger - ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes:' # Of Descriptions: ' Copies: Copies: ❑ Structural Plans '[ l i Revised Structural Plans ❑ Structural Calcs K,• ( Revised Structural Calcs ❑' Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report ' ❑ Revised Soils Report ❑ Correction List Approved Structural Plans ❑ Redlined Structural Plans Approved Structural Calcs ❑ ; Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soil's Report ❑ Redlined Soils Reports ❑ ` Other: Comments: r ' .��, Qll1L. 04SL. Thank you!• This Material Sent for•: „ ❑ • Your Files Per Your Request ❑ Your Review ❑ *Approval ❑ Checking ❑,. At the request of: Other: ❑ < By. Palm Desert Office ❑ # (76) 360-5770 Washington Office: ❑ # (760) 404-9556 J CITY OF LA QUINTA - PUBLIC' WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 Green Sheet approvals are forwarded to the Building. & Safety D.e artment direct) b Public Works. .Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are. complete. Incomplete applications or applications which cannot be.processed will be returned to applicant. Date: -'5 0*_ -0J= Developer: jn, H 4 L I:TZ_K Tract No.: Tract. Name. -� i-1\ Cl A -t. ! �� Lot No. (s): G1 .Address (s); &_ l'� i A,& A_ P n �, n �..� � e . i The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Saf CUSTOM HOMES: PROVIDE ITEMS #2. #3_ #4 amn it r, ttG� ntni ❖ . TRACT HOMES:. PROVIDE ITEMS #1 #2 #3 #4 AS APPLICABLE AND #6 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS .#1 #2 #3 AND #5 BELOW WALLS: PROVIDE ITEMS #7 BELOW • SIGNS: PROVIDE ITEMS #8 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building Pad (maximum allowable deviation of . + /- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please. withhold green sheet submittal until a Pad Elevation Certificate can be provided. Attach geotechnical certification of grading. plan compliance. 3 Attach recorded final map.showing proposed building locations are legal lots. Attach a completed < I. acre per lot or infill project Fugitive Dust Control project information form, PM 10 plan & agreement or provide alternative & valid City approved PM 10 plan set reference number' or hard copy plan. PM 10 plans for commercial & residential developments (beyond 1 lot) are 0.submitted separately with grading plans &' are subject -to additional. requirements. .Attach an approved precise. grading plan for the building location(s). AO flood zone developments will require an a q approved floodplain development plan. 6. Attach an approved rough grading plan for the building location(s). 7'. Attach wall plan & related approved grading.plan., 8. Attach sign layout/plan & related precise gradirig/landscape plan. have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to find_ingss, ab ve ect may be released for building permit iss ance. Recommended by: v` Dated: Public Works Distribution: ("�► Green Sheet to Building & Safety counter (_) Green Sheet to Community Development Declined for approval for reason(s) as follow(s), please correct and resubmit: City of La Quinta - PM 10 Project Information (< 1 acre per Lot or Infill Project) Page 1 of 3 Form updated & effective 8/25/2005 Project Information Project Contractor: Project Phase Project Phase (Chec - One): Project Name: m. por Construction Project Tract Number:'- 2 Demolition Lot Number(s): Anticipated Start Date: Anticipated Project Street Address: C �. 31C Completion: MINi W) "t rmo t> UN Total acres in active construction (< 1 acre per Lot): Project Contact Please Note: Dust control is required 24 hours a day, 7 days a week, Information regardless of construction status. Person listed below is responsible for dust control during business and non- business hours. Name: CkA &L LVL Title: (!,V%N1Vi{LD,�-- Company Name: Mailing Address: City: Qt15D<�D p State: Zip Code: Primary Telephone � Z��-'�-[ �® -1 Number: Fax: O - Z 24 Hour Access/Emergency Phone: Cell Phone: - V 111 _10> PM 10 Certificate -To !�19_ P (L O V(0 U) MOIL (pOm Number: ❖ Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. _City of La Quinta - Site Specific Construction Phase PM 1O'Agreement Page 3 of 3 Agreement updated &. effective 8/25/2005 The signature of the property owner (or authorized representative) Shall act as his/her acknowledgement of'Aust control 'requirements and their enforceability, pursuant to AQMD Rules 403 and 403.1; ❖ Shall constitute and agreement to comply -with all - project conditions as identified in, the approved dust control plan; The property owner (or authorized representative) ❖ Acknowledges that dust• control is .required .24 hours a day,. 7 days, a week, throughout the period of project performance, regardless of" project size or status; Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall be in continuous compliance with all `requirements of the approved dust control plan; ? ❖ Shall take, all 'necessary, precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or 'abatement purposes; and .Shall hold harmless the City/County and its representatives .from liability for 'any actions related to this dust control plan or ady City/County initiated abatement activities. Signature o roperty Owner or Authorized Representative Printed Nametcr a Title t Date NITs Company r o , PM 10 (< 1 acre per Lot or Infill Proiect) Fugitive Dust Control Plan Page 2 of 3 Plan updated & effective 8/25/2005 This plan shall take into account applicable SCAQMD Rule 403 regulations. Training may be obtained by contacting SCAQMD (Sharon Zamora - Phone: (909) 396-2183). This plan shall consist of the following action items: ❖ WATERING: Continuous watering is- required to prevent dust and must occur a minimum of 4 times daily. Water shall be applied to dry soils to stop: • Visible dust emissions over 20% opacity • Visible dust emissions that travel over 100 feet. • Water source 3/4 hch water meter at front (south) side of pad. ❖ EDUCATION: Responsible. Dust Control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM 10 certificate number prior to construction activity. WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Use Coachella Valley Fugitive Dust. Control Plan Handbook Construction Site Signage Guidelines. TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering or sprinklers. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. (15 mph maximum traffic speed). PARKING: Parking is not allowed on the pad. All vehicles must park on street (at designated areas only). TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works Inspector. (No dirt on public or private roads). Track out shall be cleaned up within one hour of incident. •:• DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist.or covered with tarp material. Larger dirt.piles will require stockpile.or grading permit. ❖ FENCING: Provide PM 10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace-PM10 fencing during the construction phase. EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. EXCAVATION .MEASURES:, -ll areas. to be excavated or graded shall be pre -watered. Water shall be applied during excavation or grading operations also. ❖ DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarped prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. YOUNG ENGINEERING SERVICES • Engineering • Architecture -Surveying- Building& Safety Services Letter -of Transmittal' To: CITY OF LA QUINTA Date: 05-25-07 e Project: 53-075 Via Chiante James Richards Vinci Attn: ED RANDALL PC#: 07-744(2nd) Tel No.: (760) 777-7012 Tract No.: We are forwarding: X By Messenger .. By Mail Your Pickup No. of Copies Description: ` 1 REDLINED PLANS 1 REDLINED STRUCTURAL CALCULATION 1 STRUCTURALPLANS 1 STRUCTURAL CALCULATION Comments: STRUCTURAL CONTENTS ARE APPROVABLE AT THIS TIME THANK YOU This Material Sent for: Your Files Per Your Request Your Review X Approval ' Checking At the request o£. Other By: JASON APPLEBY Phone # (760) 404-9556 77-804 Wildcat Drive, Suite C Palm Desert, CA 92211 (760) 360-5770 Bronz Young ,- Certificate of Occupancy U ��IVIf'IN G OF'TBuildin & Safet Department 9► Y p This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-075 VIA CHIANTE Use classification: SINGLE FAMILY DWELLING - SFD Building Permit No.: 07-0744 Occupancy Group: R - 3 Type of Construction: V - NR Land Use Zone: RL Owner of Building: BLAKE SCHWATZMAN Address: 3033 RIKKINS DRIVE City, ST, ZIP: WESTLAKE VILLAGE, CA 91362 �a By: AJ ORTEGA Date: FEBRUARY 27, 2009 Building Official POST IN A CONSPICUOUS PLACE e Bina # City. of La Quinta Building 8Z Safety Division V) P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA, 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Perri # VV Project Address: 0 '� C ���` / P` Owner's Name: A. P. Number: Address: 30 3-3. 1P-� Legal Description: City, 5T, Zip: Contractor: ,/�,�Le,./, Cn� �, 1� r � Telephone: _ q�G- 0 Address: zi�3 Project Description: City, ST, Zip: �cv�/z�-� 01\%5 CA— 1.36 Telephone: W 305-376 5' State Lic. # : G City Lic. #: Arch., Engr., Designer: G< < e� p(� k C Address: City, ST, Zip: M k1 -- Telephone: _ 7 ZZ — )'� ` i State Lic. #: Name of Contact Person: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft:: # Stories: # Units: Telephone # of Contact Person: CDC) -3 Estimated Value of.Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING. PERMIT FEES 121 Plan Sets, Plan Check submitted 101 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit . Truss Cates. Called Contact Person Plan Check Balance Energy Calcs. Plans'picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready for correctios/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of.permit issue , School Fees Total Permit Fees 7/Z���� NIS r�� ��o�l � gip' M >r TITLE 24 REPORT Title 24 Report for: Schwatzman / Heisser Residence .53075 Via Chiante Hideaway - Lot 196 La-Quinta, Ca _92253 t Project Designer: Atelier Architects 13743 Ventura Blvd..Suite 270 Sherman Oaks, Ca. 91423 (818) 788-6522 'Report Prepared By; Robert Mosqueda 1/INCI & ASSOCIATES 31324 Via Colinas, Suite 101 Westlake Village, CA 91362 (818) 575-9531 r Job Number: _ 06-3282 ;Date: .. i 6/8/2007' ' . The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building. Energy Efficiency Standards. This program developed by EnergySoft, LLC'- www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 064282 User Number: 5099 1 TABLE OF CONTENTS _ 1 Cover Page 1 ' Table of Contents 2 Form CF-1 R Certificate of.Compliance 3 Form MF-1 R Mandatory Measures Summary 7 ' Form WS-5R Residential Kitchen, Lighting 9 HVAC System Heating and Cooling Loads Summary 10 1 1 1 EnergyPro 4.3 by EnergySoft Job Number: 06-3282 User Number: 5099 OPAQUE SURFACES Insulation Certificate Of Compliance • Residential (Part 1 of 4) CF -1 R Azm. Tilt Wall Wood 726 n n74 R-14 R -n n I8ILAQ Wall Wnnd 137-0OZ4R-19_-B-0-0_-279_-9A ' den .ce--_---_-.-.--__--- _ 6/_8/200-7__ - 'Wall Wall Wnnd 547 n_n74 R-19 R-0 0 _S.chwatzmanJ_Heisse.r-Resi Project Title Date - -- i gn 18 Via Chiante_H.id.e.awa_y_-Lot-1.96__La Quinta__ -------- Building Permit#_ - '-530-7_5 Project Address �LI1SLCL&A_ SSOCIAT_ES -(818) 575-9531 plan Check/Date -WaU - Wood- 270_ -0.074 -R19_ R-0.0 x.090 Documentation Author Telephone 15 -EneIg_y_Pso - - Field Check/Date Climate Zone _ Compliance Method TDV Standard Proposed Compliance kBtu/sf- r) Design Design Margin 'Space Heating 2.32 2.53 -0.21 Space Cooling 60.35 53.88 6.47 Fans 8.56 9.43 -0.86 'Domestic Hot Water 4.15 3.90 0.00 0.00 0.26 0.00 Pumps Totals 75.39 69.73 5.65 Percent better than Standard: 7.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Single Family ❑ Addition Total Conditioned Floor Area: 5,820 ft2 ' E:1Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S)180 deg Raised Floor Area: 1,078 ft2 ft2 Fuel Type: Natural Gas Slab on Grade Area: 4,001 ' Fenestration: Average Ceiling Height: 9.0 ft Area: 1,394 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Ratio: 23.9% Avg. SHGC: 0.28 Number of Stories: 2 ' BUILDING ZONE INFORMATION # of Thermostat Type Type Vent Hgt. Area Zone Name Floor Area Volume Units Zone HVAC System 5 99nR9n 59 3Rn SOD_ Conddioned- _-Setback- S -n/a OPAQUE SURFACES Insulation Act. ' Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wood 726 n n74 R-14 R -n n I8ILAQ Wall Wnnd 137-0OZ4R-19_-B-0-0_-279_-9A _Ist Flonr Wood 616 0 074 R-19_ _B=0.0 0 9.0 'Wall Wall Wnnd 547 n_n74 R-19 R-0 0 -9.0- 90 Boni- Wbod- 4 on1 _.032_ R-30 _S -0_.0 Floor wood- ___,0Z8_ _0.048_ -B_19_ R-0-0 i gn 18 W.211 W od- ---334- _0 074 R_19 _B-0_0_. -180_-9.0 ' Wall Wood- 366_ n 074 X19_ -8 09. -279_ 9 W211 -Wood- 334 _0.074 -R-19.1 0..0_ -0_ 90 -WaU - Wood- 270_ -0.074 -R19_ R-0.0 x.090 Boo, Wood- -1 OZ8 -0.032 X30_ X0_0 --180- Gains Condition Y / N Status JA IV Reference Location / Comments New 09 A5 Ast_Eloor New MA5 1st Floor - New n9 -A5 1 ct Floor New Dg -A5 _Ist Flonr New 01-A17 1 q Floor - New21-A4 2nd_Floor New _O _A5 2nd Floor New _09A5 2ndJloor Ne_w A9_ 2nd_Soo NAW _o9__4_5 2nd_Boor New 91 A1.7 2nd/ loot Run_Initiation Time:_06/08/07 10:53_59____.,_.,_Run,Code: 1181325239-,-___.__._.-_.____.__-__.___._._.___._..:..-._. Ener ro 4.3 b Ener oft User Number: 5099 Job Number: 06-3282 Page_3 of 10 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Schwatzman / Heisser_Residence 6/8/2007 Project Title - Date FENESTRATION SURFACES True Cond. Location/ # Type - - Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments _ ' 1- 2 _Wjndow-Front_(S)_ X4.9.0_ -0_340-NER ._0 28 -NERC Window Left (1/V)_ 486.0 0.340 NFRC 0_28 NFRC 1-80- 270 -9.0- New Loew.en-Dbl/-Wo-od-Lo-w=E 90 New Loewen Dbl/Wood Low -E 1.st.soor 1st Floor 3 Window Rear (N)_ 359.2 0.340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wood Low -E 1st Floor 4 _ Window Right E 76.0 0.340 NFRC 0_28 NFRC 90 90 New Loewen Dbl/Wood Low -E _ 1st Floor Window Front (S) 63.8 0.340 NFRC 0_28 NFRC 180 90 New Loewen Dbl/Wood Low -E 2nd Floor '5 6 Window Rear (N) 63.5 0.340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wood Low -E 2nd Floor 7 Window Ri ht (E) 96.0 0_340 NFRC 0_28 NFRC _ 90 _ 90 New Loewen Dbl/Wood Low -E 2nd Floor 1 - 1 - 'INTERIOR 1. Indicate source either from NFRC or Table 116A. AND EXTERIOR SHADING # Exterior Shade Tvpe SHGC 2. Indicate source either from NFRC or Table 116B. Window Overhanq Left Fin Right Fin Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. ' 'Area 1 By Screen 0.76 5.0 2 Bug Screen 0.76 7.0 3 Bug Screen 0.76 3.0 4 Bug Screen 0.76 6.0 5 Bug Screen 0.76 _3.5 6 Bug Screen 0.76 3.0 7 Bug Screen 0.76 2.0 THERMAL MASS FOR HIGH MASS DESIGN Thick.Heat Type (so (in.) Cap. Cond. 5.0 7.0 3.0 6.0 2.5 3.0 2.0 Inside R -Val. 2.0 0.1 2.0 2.0 0.1 2.0 2.0 0.1 2.0 2.0 0. 20 2.0 0.1 2.0 2.0 0. 2.0 2.0 0.1 2.0 JA IV Reference 2.0 2.0 2.0 20 2.0 2.0 2.0 Condition Location/ Status Comments PERIMETER LOSSES Insulation Condition Location/ ' Type - Length R -Val. Location _ JA IV Reference -Status Comments New ___ --- Slab Perimeter _ 374 None No Insulation 26-A1 w 1st Floor EnergyPro 4.3 by EnergySoft User Number 5099 Job Number: 06-3282 Page:4 of 10 i Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Schwatzman / Heisser Residence _ _ _-6/8/2007___—_ Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff —_ Type -- Eff _Status --_Type HVAC System Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback. HVAC DISTRIBUTION Location Duct Duct Condition Ducts Coolinq Location R -Value Status Tested? HVAC System Ducted Ducted Attic 8.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A O Smith Water Products FPSH-75 Small Gas No Pipe Insulation 1 75,000 75 New 0.62 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Robert Mosqueda Title/Firm: Atelier Architects Title/Firm: VINCI & ASSOCIATES Address: 13743 Ventura Blvd. Suite 270 Addre 31324 Via Colinas Suite 101 Sherman Oaks, Ca. 91423 /� Westlake Village, CA 91362 Telephone: (818) 788-6522 Lic. #: _ elepho : (8fj8) 575-9531 — (date) (signature Enforcement Agency Name: Title/Firm: Address: Telephone: -------- - -- — ------------ (signature) (date) JUN 0 8 1007 (date) .. I - ._EnergyPro 43_by EnergySoft. _ .._. User Number. 5099... _— .. __... .. _... -_ Job Number. 06-3282_.. - . .._ - ..__ . _, .Page; 5 of 10__ _ ._ Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Schwatzman / Heisser Residence _--_ 6/8/2007_ --- Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -411 Plan Field installation certificate. The Cooling System 'Bryant 556AN036-E/350MAV036060" includes credit for a 12.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.3 by EnergySoft User Number: 5099 Job Number: 06-3282 Page: of 10 1 - ...__.-.-_ __.____ __ __ _. _. - - ---. _. -- --- _ __ . . 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (')below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures +§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). f§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑X ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ r_x� ❑ 1. Masonry and factory -built fireplaces have`. ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox' © ❑ ❑ b. outside air intake with damper and control, flue damper and control 19 ❑ ❑ 2. No continuous burning gas pilot lights allowed. ® ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑X ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. © ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑X ❑ permeance rate no greater than 2.0 permfinch. f Ll 1 ❑❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ RX ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and'lnfiltration/Exfiltration Controls. �T ❑ U 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ a ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ E ❑ Space Conditioning, Water Heating and PlumbingSystem Measures ❑ ❑ § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ r_x� ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.X❑ ❑ ❑ § 150(1): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑x ❑ § 150a): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire El r� I ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ❑ f� [ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. f Ll 1 ❑❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ 13 0 and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed �T ❑ U entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. II FXJ, 1-1 �l L.1 EnergyPro 4.3 by EnergySoft User Number. 5099 Job Number: 06-3282 Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not DESCRIPTION applicable. N/A ENFORCE - DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table § 150(m): Ducts and Fans 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of luminaire has factory installed HID ballast. R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceded to comply with Section 119(d). or tape shall be used. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages; laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article reductions in the cross-sectional area of the ducts. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive Q ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more N ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. EnergyPro 4.3 by EnergySoft User Number. 5099 Job Number: 06-3282 PaC of 10 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ - ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. © ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the Q ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. 0 ❑ ❑ b. Cover for outdoor pools or outdoor spas. © ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. © ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria © ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceded to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages; laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1`19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are Q ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ® ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more N ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number. 5099 Job Number: 06-3282 PaC of 10 Residential Kitchen Liqhtinq Worksheet WS-5R ' Schwatzman / Heisser Residence _ 6/8/2007 Project Title Date ' At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not'high efficacy must be switched separately. ' Kitchell Lighting Schedule. 'Provide the following information for all luminaires to be installed in kitchens. - High Efficacy Luminaire Type High Efficacy? Watts Quantity_ _- Watts Other Watts ' 40w Recessed Incandescent Yes 7 No X 40:0x� or 3 70w Metal Halide Yes X1 No 1 86.0 x1 �— -- _ or t �l ^T— Yes No X - or Yes No x _ or Yes No x or Yes No x = or Yes No x = or Yes No x = or ' Yes No x or Yes No x or Yes No x = or Yes No x = or Yes No 1 x or Yes No { _ x or Yes No x = or ' Yes No x = Yes No x = or or Yes No x - or Yes No x = or Yes No x - Total A: 2 i or 1 :tea: ' J100 :, , COMPLIES IF.A z B YES ® NO ❑ �_......EnergyPro4_3 byEnergySoftr - User Number. 5099 _.-..._....�-.._.___..._t.Job Number.. 06-3282___ :....._._......- _..-..._Page,9of10,._.._� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ' PROJECT NAME DATE Schwatzman / Heisser Residence _ 1_ 6/8/2007 SYSTEM NAME FLOORAREA _HVAC System — 5,820 _ ENGINEERING CHECKS SYSTEM LOAD 1 1 1 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensiblel Latent I CFM TSensible 6,759 74,345 8,780 1,997 79,907 0 10,890 7,985 0 0 0 0 0 0 0 0 0 10,890 7,985 TOTAL SYSTEM LOAD 1 96,1251 8,780 95876, HVAC EQUIPMENT SELECTION Bryant 556AN036-E/350MAV036060 48,180 20,985 112,000 Total Adjusted System Output 48,180 20,985 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating P� 26.0°F 66.9°F 66.9°F 110.70F 0. Supply Air Ducts Outside Air 0 cfrrl Supply Fan Heating Coil 107.6 °F t 2400 cfm ROOMS 70.0 OF 66.9 °F' I Return Air Ducts 'COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 82.3/69.4°F 82.3!69.4°F 63.4/62.4°F '310 4 Supply Air Ducts �• Outside Air 0 cfm Supply Fan Cooling Coil 67.7 / 63.8 OF 'k. 2400 cfm 60.8% R.H. ROOMS] 82.3/69.4of 78.0 / 68.1 OF ' Return Air Ducts <-- -EnergyPro 4.3 by EnergySoft UserNumber: 5099 Job Number: 06-3282 i Page: 10 of 10 ot , t" BOX 1504 APPLI�AOILY "Building y /` 0� 78-495 CALLE TAMPICO Address LA QUINTA, CALIFORNIA 92253 Owner BUILDING: TYPE CONST.Mailin/ C OCCP. C.. GR Address 3a3 3 �c �1��-� «.�, A.P. Number L-t �` 6 (� - "` P 'C3il� 1 Zip ITel. Legal Description Con ctor Project Description Address Cly � Zip Tel. State Lic. 'City Sq. Ft. No. No. Dw. & Classif. 7�15 (� Lic. # Size Stories Units Arch., Engr., + New Add ElAlter ElRepair ElDemolition ElDesigner Address Tel. ity Zi State Lic. # 1 S D CONTRACTOR'S DECLARATION I hereby aff/o3l� censed under provisions of Chapter 9 (commencing with Section 70 0) of Diviusiness and Professions Code, and my license is in full force and effect. 4— Z _V -� SIGNATURE DATE OWNER-BUILDER DECLARATION Estimated Valuation I y affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also PERMIT AMOU requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis Plan Chk, Dep, for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). Plan Chk. Bal. ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- Const. cions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided Mech. that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner-builder will have the burden of Electrical proving that he did not build or improve for the purpose of sale). ' "����-�—•- ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct Plumbing theSec. ect. j ro7044, Business and Professions Code: The Contractor's License Law does k = p ( S.M.I. not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) Grading " 8 M ($ S Et ❑ 1 am exempt under Sec. B. & P.C. for this reason -.M Driveway Enc. Date Owner Infrastructure WORKER'S COMPENSATION DECLARATION�`e� ° I hereby affirm that I have a certificate of consent to self-insure, or a certificate of Worker's ; C t r k "" { Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) -- - Y'k '- e.=. ` 14 Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM TOTAL WORKERS' COMPENSATION INSURANCE (This section need not be completed if the pe it is :eC r one hundred d Lars ($100) valuation REMARKS or less). I certify that in the performance oft k for ' this permit is issued, I shall not employ any person in any manner so as co e st to Workers' Compensation Laws of Califor ia. Date� ( Xner NOTICE TO APPLICANT.. If, after king this Certificate of Exemption you should become subject to the Workers' Comp en at provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: CONSTRUCTION LENDING AGENCY Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work Rear Setback from Rear Prop.Line for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Side Street Setback from Center Line Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to Side Setback from Property Line expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. FINAL DATE INSPECTOR I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Issued by: Data Permit Signature of applicant Date Mailing Address Validated by: City, State, Zip Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE APPLICATION.# ADDRE .S VALUATION,. -SQ. FT.� st ` l FLOOR `F ` nd 2` FLOUR,: COVERED PATIO GARAGE _TYPE CONST:. ---- OCCUPANCY A/C �. FIRE .SPRINKLER`- # .OF BEDROOM # ORUNT`5 .. ODL EDITION .. ROOF TYPE . MECI3ANICAL - # NT FANS # EXHAUST HOOD A/C -<3 TON A/C >3 TON a FAU <100,000 -BTU FAU >1001000 BTU BY UNIT COUNTS.. / GAS TOILETS 11 BIDET. SHOWERS .BATHTUBS I.J . S INKS 0. BAR SINK.) OVEN RANGE. :COOKTOP: ` . DRINKING` FOU] WASHER'. DRYER WATER HEATER ROOF. DRAINS FLOOR DRAINS KITCHEN SINK VEG SINK. - LAUNDRY SINK FIREPLI CE 03/06/2007 11:36 FAX 8188790697 RECORDING REQUESTED BY Ff>ftSTAMERICAN TITLE CO. _ RIVERSIDE RESALE AND WHEN RECORDED MAIL TO: Chris Heiser or Assignee 0 BTI CHEMICAL 10 003 f ...._. DDC ...# 2006 -026"6: 04i12r2M 08.W Fa4.33.01a Page i of 3 DOC T -tax Paid Recorded in Official Records v - County of Riverside Larry W. Yard Assessor, County Clark S Recorder r II!lIIIIlIIHII!lIlll111111lI!!lINIIIIIII!lIIIII�IlII A.P.N.: 777-210-010-5 ` :} GRANT DEED TheUndersgnedG:ranWs)Dedwc(s): DOCummrARYTRANSFER TAX $75&75;•C17YTRANSFER TAX $0.00; X ] computed on the considerMn or full value of property tmive*, OR ] computed on the ar sideration or full value km value of and/or er"n b w= remaining at time of sale, f ] un orporated area; [ X ] city of la Quina, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Richard L. Corbin and ]anise M. Corbin Revocable Trust, dated October 2, 2002 hereby GRANTS to Blake R. Sebwa tzman a umarrieA man the following described property in the City of La Quanta, County of Riverside, State of Cal"rfornia: Legal description as per Exhibit "A" attached hereto and made a part hereof. Dated: 03/08/2006 i I Mail Tax Statements To: SAME AS ABOVE IM 004 03/06/2007 11:36 FAX 8188790697 BTI CHEMICAL A.P.N.• 777-210-010-5 Grant Deed - continued File No.:RPla-2291195?'° (dpi`:' ';;:..;.;;',:. Date: 03/0612096 .. Richard L. Corbin and Janice M. Corbin Rev ble Trust , Richard L.Corbin Trusstte�e _ ni M. Corbin, Trustee i I j STATE OF 1 i ta )SS COUNTY OF On _ j 40 before me, * rG►�r�Sl�'-t . iti,��l"-.r it Yc�t�� �.► Notary Punic, personally appearede- E2, s are subscribed to ( proved oved to me on the basis of satisfactory evidence) to be the person(s) whose name()/ their authorized the within instrument and acknowledgedto me that hie/they ematted the same in WsAwl capacity(les) and that by bier/their signatures) on the Instrument the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seat. a Caimllnlon01407577 Sttn 6�txsdna Li Signature NhrCamnaDaooxi My Commission Expires: 1 i , j , � c0677 77Ms amp for vwal notarial seal Notary Name: Notary Phone: Notary Registration Number: County of Prindpal Place of SUSIrWs:. page 2 of 2 03/06/2007 11:36 FAX 8188790697 BTI CHEMICAL ►� oo� 0 Title Order Number.; Ale Number: ` RPD -2291105 Exhibit "A" Real property in the City of La Quinta, County of Riverside, State of California, described as follows: j PARCEL 1: I LOT 196 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES) 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. APN:777-210-010-5 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FFF.S PATD AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hieawa/Sewatzrnan/ipxsse Date: 06/18/07 Owner's Name: Hideaway/Schwatzman/Heisser Phone No. 818-309-3765 Project Address: 53-075 Via Chante Project Description: 1 SFD APN: 772-550-010 Tract #: Lot # Type of Development: Residential Commercial Total Square Feet of Building Area: 5820 sq. ft. Certification of Applicant/Owners: The person signing certifies that the ab*76,e information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sigff behalf of the owner/developer. Dated: 06/18/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 5820 sq ft Amount per Sq.Ft. $ 3.91 per sq. ft. Amount Collected $ 22,756.20 By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Maria L. Angulo, Facilities Secretary Signature: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees.Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. T_ :e/ mydoes;devfees/Certificate of compliance form cablesTO USELloc 1/16/03 T YOUNG ENGINEERING SERVICES 0 Engineering • Architecture•Surveying• Building & Safety Services Letter of Transmittal To: CITY OF LA QUINTA Date: Project. Attn: ED RANDALL PC#: Tel No.: (760) 777-7012 Tract No.: We are forwarding: No. of Copies 1 1 1' 1 05-25-07 53-075 Via Chiante James Richards Vinci 07-744(2 n ) X By Messenger By Mail Your Pickup Description: REDLINED PLANS REDLINED STRUCTURAL CALCULATION STRUCTURAL PLANS STRUCTURAL CALCULATION Comments: STRUCTURAL CONTENTS ARE APPROVABLE AT THIS TIME THANK YOU This Material Sent for: Your Files Your Review Checking Other By: JASON APPLEBY Phone # (760) 404-9556 Per Your Request X Approval At the request of- By: £ 77-804 Wildcat Drive, Suite C, Palm Desert, CA 92211 (760) 360-5770 Bronz Young k CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 Green Sheet approvals are forwarded to the Building. & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: ® Developer: 10 1 , Tract No.:_!) —n„bractName:��� air,-�--�� Address(s): The following are the requirements for Public Works Clearance to authorize issuance of a building from the Building r,art„-, & Safety nPp„t. g permit MES: PROVIDE ITEMS #2 #3 #4 AND # LEB5 O ------------------------ TRACT HOMES: PROVIDE ITEMS #1 #2 #3r #4 AS APPLICABLE AND #6 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS .#1 #2 #3 AND #5 BELOW ❖ WALLS: PROVIDE ITEMS #7 BELOW ❖ SIGNS: PROVIDE ITEMS #8 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of . +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months -of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. Attach geotechnical certification of grading. plan compliance. 3 Attach recorded final map showing proposed building locations are legal lots. OAttach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM 10 plan set reference number or hard copy plan. PM 10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. Attach an approved precise grading plan for the building location(s). AO flood zone developments require an a p ents will re q approved flood plain development plan. 6. Attach an approved rough grading plan for the building location(s). 7. Attach wall plan & related approved grading.plan. 8. Attach sign layout/plan & related precise grading/landscape plan, have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to findings, ab ve ject may be released for building permit iss ance. I G� Recommended by: Dated:' . Public Works Distribution: (_) Green Sheet to Building &Safety counter (_) Green Sheet to Community Development Declined for approval for reason(s) as follow(s), please correct and resubmit: City of La Quinta - PM 10 Project Information (< 1 acre per Lot or Infill Project) Page 1 of 3 Form updated & effective 8/25/2005 ❖ Expanded PM 10 plans for commercial and residential developments > .1 acre are required by the City of La Quinta. Project Information Project Contractor: Project Phase Project Phase �hecOne): Project Name: is 006 Construction Project Tract Number:' Z ❑ Demolition Lot Number(s): Anticipated Start Date: `q Anticipated Completion: Total acres in active Project Street Address: ✓ construction (< 1 acre per Lot): is required 24 hours a day, 7 days a week, status. Person listed below is responsible business and non- business hours. Project Contact Information Please Note: Dust control regardless of construction for dust control during Name: CIA& CA - Title: al& Vl. bA _ Cet L Company Name: ^ �.j ^ J Mailing Address: City: O050< D - State: Zip Code: Primary Telephone Number: ®� 2—q t —Tk �o Fax: 0 2 24 Hour Access/Emergency Phone: Cell Phone: PM 10 Certificate - o �j p_ P a 0 v(0 a) FrX CON 51, ® Number: ❖ Expanded PM 10 plans for commercial and residential developments > .1 acre are required by the City of La Quinta. PM 10 (< 1 acre per Lot or' Infill Project) Fugitive Dust Control Plan Page 2 of 3 Plan updated & effective 8/25/2005 This plan shall take into account applicable SCAQMD Rule 403 regulations. Training may be obtained by contacting SCAQMD (Sharon Zamora - Phone: (909) 396-2183). This plan shall consist of the following action items: ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of 4 times daily. Water shall be applied to dry soils to stop: • Visible dust emissions over 20% opacity • Visible dust emissions that travel over 100 feet. • Water source % hch water meter at front (south) side of pad. ❖ EDUCATION: Responsible. Dust Control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM 10 certificate number prior to construction activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Use Coachella Valley Fugitive Dust. Control Plan Handbook Construction Site Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering or sprinklers. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. (15 mph maximum traffic speed). ❖ PARKING: Parking is not allowed on the pad. All vehicles must park on street (at designated areas only). TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works Inspector. (No dirt on public or private roads). Track out shall be cleaned up within one hour of incident. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile.or grading permit. ❖ FENCING: Provide PM 10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace.PM10 fencing during the construction phase. EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. ❖ EXCAVATION MEASURES: -,All areas. to be excavated or graded shall be pre -watered. Water shall be applied during excavation or grading operations also. ❖ DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarped prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. Lc OPecmc construction Phase PM 10 Agreement Page 3 of 3 Agreement updated & effective 8/25/2005 The signature of the property owner (or authorized representative) ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to AQMD Rules 403 and 403.1; ❖ Shalt constitute and agreement to comply with all project conditions as identified in the approved dust control plan; The property owner (or authorized representative) ❖ Acknowledges that dust control is .required 24 hours a day, 7 days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan.- Shall lan; Shall take all necessary. precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or abatement purposes; and •3 Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature Name Title Company rty Uwner or Authorized Representative M Date Bir, # City of La Quinta (�' Building U Safety Division �� P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Peri # '9 Project Address: Owner's A. P. Number: Address: 3033 t � (_ I' X*4 Legal Description: Contractor: ,A�t e /� Ccs � 1� � Address: 3- 3>, L V211 i City, ST, Zip: Telephone: P2— (4o6-50' Project Description: 6 k. /,c -'G (-, City, ST, Zip: �/�cci�/z� %GS Telephone: Rie 3 0 �•--3 % City Lie. #: State Lie. # : 5 Arch., Engr., Designer: Address: (3 7q I L&AAo uv U& Z 7.6 City, ST, Zip: r All.. -PN q1 Lt -z Telephone: Rt "'%'Z7i — i State Lie. #: Name of Contact Person: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft:: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Ree'd TRACKING _ PERMIT FEES Plan Sets. Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans bicked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan r' Review, ready for correctio s/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees O S 11'W /01 SI -g 4?P*kv 1 April 17, 2007 Mr. and Mrs. Chris Heisser 3033 Rikkard Drive Thousand Oaks, CA 91362 RE: Schwartzman /Final Design Review Lot 196 at 53075 Via Chiante Dear Mr. and Mrs. Heisser, Thank you for your attendance yesterday at the Hideaway Design Review Committee meeting. Your response comments and new plans were accepted by the Committee for review. The project was conditionally approved for you to begin construction. All of the items from our letter dated April 9, 2007 will need to be resolved prior to the setback inspection, please see the attached letter. The following items were discussed with you yesterday and will need to be incorporated into your next submittal of plans: 1. The side yard balcony will need to be screened with two 48" box California Pepper trees. 2. The proposed lamps to be used as the exterior wall mounted fixtures were not approved for use because they have 4 lamps per fixture which would exceed the Hideaway requirements of 25 watts or less per fixture. Less candle power will need to be used. 3. The plans will need to be resubmitted to show the 10" thick walls, not 6". 4. The garage door as submitted was approved for use. 5. Structural header will be required, not a "plant on". 6. A variance is required to have the pool at 5' from the property line. We have a variance request on file, but it is not for the location of the pool. Any deviation from the Design Guidelines must be submitted with a request for a Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process, it will be the design team's responsibility to make modifications at a later date if required by the Design Review Committee. Please contact Mindy Gutierrez at (760) 391-5211 with any questions. Sincerely, Hideaway Design Review Committee cc: Mr. Heisser at Chrisheisserhh@aol.com DRC File Letter of Transmittal To: City of La Quinta Today's Date: ❑ Your Review ❑ Checking 78-495 Calle Tampico City Due Date ❑ La Quinta, Ca 92253 Project Address: Attn: Plan Check #: Submittal: 1St ❑ 4th ❑ 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans Revised Structural Plans ❑ Structural Calcs KL t Revised Structural Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report ❑ Revised Soils Report ❑ Correction List �fl % Approved Structural Plans ❑ Redlined Structural Plans Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Thank This Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ By: Palm Desert Office: ❑ # (76) 360-5770 Washington Office: ❑ # (760) 404-9556 Per Your Request ❑ Approval ❑ At the request of: VINCE & ASSOCIATES cSipuclural 6nyineers YU L 7 2007 STRUCTURAL CALCULATIONS FOR [By FIELD REVISIONS SCHWATZMAN / HEIZo"'iSEKv'% RESIDENCE 0 Hideaway Lot # 196 La Quintp, lqalifornia l< C;n CITY OLA QUI BUILDINGf-&� SAF DEPT. A, VED , 1 FOR Go"\'lsx� T: i i 'r chitects DATE-!�—&�--7 B OB,, NO: 06-3282 31324 VIA COLINAS STE 101 WESTLAKE VILLAGE, CA 91362 p818.575-9531 9 f8I8.575-9581 . evinci@vincise.com WoodWorks® Sizer Beam 67-revised_wbc SOFTWARE FOR WOOD DESIGN WoodWorks@ Sizer 7.0 COMPANYI PROJECT V I N C I & A S S 0 C I A T E S I Schwatzman / Heisser Residence 31324 Via Colinas, Suite 101 1 Via Chianti Westlake Village, California I La Quinta, California I V&A Job No. 06-3282 DESIGN CHECK - NDS 2005 Beam DESIGN DATA: Material: Glulam-Balanced Lateral support: top= full, bottom= at supports; Total length: 9.58 [ft.] Load combinations: ICBO-UBC; LOADS: (force=lbs, pressure=psf, udl=plf, location=ft) »Self -weight automatically included<< ----------------------- Load I I Type IDistributionl Magnitude I Location I Pat - I I I Start End I Start End I tern ----------------I--------I------------ I----------- bm 61-d1 Dead Point 3855 0,00 No bm 61-11 Constr. Point 2304 0.00 Yes bm 62-d1 Dead Point 6698 0.00 No bm 62-11 Constr. Point 3854 0.00 Yes bm 60-d1 Dead Point 2878 9.58 No bm 60-11 Constr. Point 1720 9.58 Yes wall Dead Partial Ar 15.00(10.00)" 2.75 9.58 No rf-dl Dead Full Area 25.00 (1.33)+ No rf-11 Constr. Full Area 16.00 (1.33)• Yes -Tributary Width (£t) MAXIMUM REACTIONS and BEARING LENGTHS (force=lbs, length=in) 1 2.75 6.83 ft I ---------- ---------------------------- Uplift 1 3192 Dead 1 15680 - Live 1 8780 1792 Total 1 24460 1090 Load Case[ #0 #2 #4 B.Length 1 0 7.34 0.5•' *Min_ bearing length for beams is 1/2" for exterior supports DESIGN SECTION: West Species, 24F -V8 DF, 5.125x18 @21..239 plf This section PASSES the design code check. ########################################################################### SECTION vs. DESIGN CODE (stress=psi, deflection=in) ------------------ ____________________________________________________________ Criterion I Analysis Value I Design Value I Analysis/Design I -------------- I ----------------I---------------- I ------------------I Shear fv = 274 Fv' = 331 fv/Fv' = 0.83 Bending(-) fb = 2005 Fb' = 2936 fb/Fb' = 0.68 Deflection: Interior Live -0.02 = <L/999 0.23 = L/360 0.08 Total -0.05 = <L/999 0.34 = L/240 0.15 Cantil. Live 0.06 = L/573 0.18 = L/180 0.31 Total 0.15= L/214 0.28 = L/120 0.56 FACTORS: F/E CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# Fv' 265 1.25 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'- 2400 1.25 1.00 1.00 0.979 1.000 1.00 1.00 1.00 1.00 - 2 Fcp' 650 - 1.00 1.00 - - - 1.00 - - - E' 1.8 million 1.00 1.00 - - - - 1.00 - - 3 Emin' 0.85 million 1.00 1.00 - - - - 1.00 - - 3 Custom duration factor for Wind load = 1.33 ADDITIONAL DATA Shear LC 42 = D+C, V = 16919, V design = 16828 lbs Bending(-): LC 92 = D+C, M = 46242 lbs -ft Deflection: LC #3 = D+C (pattern: C_) EI= 4483e06 lb -int Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow W=wind. I=impact C=construction CLd=concentrated) (All LC's are listed in the Analysis output) (Load Pattern: s=S/2, X=L+S or L+C, _=no pattern load in this span) Load combinations: ICBO-UBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSI/AITC A190.1-1992 3. Grades with equal bending capacity in the top and bottom edges of the beam cross-section are recommended for continuous beams. 4. GLULAM: bxd = actual breadth x actual depth. 5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). 7.. The critical deflection value has been determined using maximum back: -span deflection. Cantilever deflections do not govern design. i J FAP r,> f - July 9, 2007 15:53:55 i 4- L-.trA'P =� Woodworks® Sizer Beam 62-REVISED.wbc SOFTWARE FOR WOOD DESIGN WoodWorks@ Sizer 7.0 COMPANY 1 PROJECT V I N C I & A S S O C I A T E S 1 Schwatzman / Heisser Residence 31324 Via Colinas, Suite 101 1 Via Chianti Westlake Village, California I La Quinta, California I V&A Job No. 06-3282 DESIGN CHECK - NDS 2005 Beam DESIGN DATA: Material: Glulam-Balanced Lateral support: top= full, bottom= at supports; Total length: 22.25 [ft] Load combinations: ICBO-UBC; LOADS: (force=lbs, pressure=psf, udl=plf, location=ft) »Self -weight automatically included<< Load I Type 1Distributionl Magnitude I Location 1 Units I I I Start End I Start End I ---------------- I -------- I ------------ I -------------- I -------------- I_____ Beam 68-d1 Dead Point 471 7.66 lbs Beam 68-11 Constr. Point 288 7.66 lbs Beam 66-d1 Dead Point 5426 12.50 lbs Beam 66-11 Constr. Point 3026 12.50 lbs Beam 63-d1 Dead Point 1916 15.00 lbs Beam 63-11 Constr. Point 1140 15.00 lbs -rf-dl Dead Partial Ar 25.00 (8.50)* 0.00 7.66 psf r£-11 Constr. Partial Ar 16.00 (8.50)* 0.00 7.66 psf rf-dl-2 Dead Partial Ar 25.00 (6.50)* 0.00 12.50 psf rf-11-2 _ Constr. Partial Ar 16.00 (6.50)* 0.00 12.50 psf rf-dl-3 Dead Trapezoida 162.5 50.0 12.50 22.25 plf rf-11-3 Constr. Trapezoida 104.0 - 32.0 12.50 22.25 plf *Tributary Width (ft) MAXIMUM REACTIONS and BEARING LENGTHS (force=lbs, length=in) 1 22.25 ft I ^ ---------- ------------------- Dead 1 6698 6434 Live 1 3854 3604 Total 1 10553 10038 Load Casel 42 02 B.Length 1 2.41 2.29 ########################################################################### DESIGN SECTION: West Species, 24F -V8 DF, 6.75x18 @27.973 plf This section PASSES the design code check. ########################################################################### SECTION vs. DESIGN CODE (stress=psi, deflection=in) Criterion I Analysis Value I Design Value I Analysis/Design 1 -------------- I ---------------- I ---------------- I ------------------I Shear fv = 121 Fv' = 331 fv/Fv' = 0.37 Bending(4) fb = 2702 Fb' = 2786 fb/Fb' = 0.97 Live Defl'n 0.40 = L/666 0.74 = L/360 0.54 }f!6 Total Defl'n 1.11 = L/241 1.11 = L/240 1.00 __ r FACTORS: F/E CD r„14 Ct CL CV Cfu Cr Cfrt Notes Cn _Fv,265 LC# 1.25 1.00 1.00____ 1.00 1.00 1.00 2 Fb'+ 2400 1.25 1.00 1.00 1.000 0.929 1.00 1.00 1.00 1.00 - 2 Fcp' 650 - 1.00 1.00 - - - -1.00 - - - E' 1.8 million 1.00 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 1.00 1.00 - - - - 1.00 - - 2 Custom duration factor for Wind load = 1.33 ADDITIONAL DATA Shear LC #2 = D+C, V = 10038, V design = 9826 lbs - Bending(+): LC #2 .= D+C, M = 82075 lbs -ft Deflection: LC #2 = D+C EI= 5905e06 lb -int Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated) (All LC's are listed in the Analysis output) Load combinations: ICBG-URC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSI/AITC A190.1-1992 3. GLULAM: bxd = actual breadth x actual depth. 4_ Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). A L`L July 9, 2007 15:40:05 40 :: .-71 DATE: 7/9/2007 V 1 C I & ASSOCIATE S SHEET: 3 PROJECT: SChwatzman/Heisser Residence JOB NO.: 06-3282 Via Chianti 31324 VIA COLINAS STE 101, WESTLAKE VILLAGE, CA 91362 ENGR.: Springer La Quinta, California p - 818.575-9531 f - 818.575-9581 e - vinci@vincise.com FOUNDATION DESIGN ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF 5-00'x 6-00'x 18" THK PAD P(allow) = (5.0'x 5.0') x (1.00 ksf) = 25.0 k (USE 1'-0" x 1'-0" MIN. PEDESTAL) Mu = 1/2 (1.6 x 1.0 ksf) (2.00^2) = 1.60 k -ft Fu = (12" x 14"^2) / 12000 = 0.196 Ku = (Mu / Fu) = 8.2 p = 0.00160 As = (12" x 14") x (0.00160) = 0.27 in^2 <= 1.02 in^2 BEAM SHEAR: v(u) = ((1.6 x 1000) (2.50 -1.50) x 1') / (.85 x (12 x 14) = 11 psi < 2 f = 89 ps O.K. PUNCHING SHEAR: v(u) = ((1.6 x 1000) (25 - 2.17)) / (.85 x 4 x (2.17 x 14) = 26 psi < 4 fc = 179 p: O.K. USE: 5-00'x 5.00' x 18" THK PAD with # 4 BARS (c—D� 12" ox. each way DATE: 7/9/2007 V I C I & ASSOCIATES SHEET: q PROJECT: Schwatzman/HeisserResidence Structural Engineers JOB NO.:' 06-3282 Via Chianti 31324 VIA COLINAS STE 101, WESTLAKE VILLAGE, CA 91362 ENGR.: Springer La Quinta, California p-818,575-9531 f-818.575-9581 e-vinCi@vincise.com FOUNDATION DESIGN ALLOWABLE SOIL BEARING = 1000 psf PAD 22 LOAD FROM: BM 67 P = 9651 lbs BM 68 P = 759 BM 62 P = 1791 12201 »»> USE: PAD B (Pail. = 12300 lbs) >>> USE: TS 4x4)'/4 (Pauow = 43000 lbs) PAD 23 LOAD FROM: STL FRM P = 4808 lbs »»> USE: PAD A (Paiiow = 6300 lbs) PAD 24 LOAD FROM: BM 60 P = 4598 lbs »»> USE: PAD A (Pauow = 6300 lbs) PAD 25 LOAD FROM: BM 67 , »»> USE: PAD D »»> USE: TS 4x4x'/4 P = 24460 lbs (Pauow = 25000 lbs) (Pauow = 43000 lbs)