07-1691 (SFD)c P.O. BOX 1504 78-495 CALLE TAMPICO _ LA QUINTA, CALIFORNIA 92253 Application Number: F`07-00001691 4 4Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Property Address: 53095 VIA CHIANTE APN: 772-550-011- - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 432025 J Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 801142 — vate- X / /�` Contractor T _ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that, I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter; improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the , permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by - any applicant for a permit subjects the applicant to_a civil penalty of not more than five hundred dollars ($500).: - 1 _ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does'not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or.her own employees, provided that the . improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). • • (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - - (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the . work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Name: - Lender's Address:. LQPERMIT Owner: HIDEAWAY JFC, 78-365 HIGHWAY 111 4177. LA QUINTA, CA 92253 Contractor: COAST & DESERT DEVELOPMI\ 783'65 HIGHWAY 111 STE 17 LA QUINTA, CA 92253 (760)567-2026. Lic. No.: 801142 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/30/07 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. . I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0030651-2.007 _ I certify that; in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section' 3700 of the Labor CodeA shall forthwith comply with those provisions. Date. Applicant: WARNING: FAILURE TO SECURE W41RKER COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ' APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. - Any permit issued as a result of this, application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. . I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enenter upon the above-mentioned prop ert or a ion purposes. -Date. _3L"�Signature (Applicant or Agent): Application Number. . . . . . 07-00001691 Structure Information- 4•,850SF DWELLING/V-NR/RES-3/CLASS A -FR ----- Other struct info . . . . . CODE EDITION 2001/2005 $$ BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1200.00 PATIO SQ FTG 1250.00 NUMBER OF UNITS 1.00 ..1ST FLOOR SQUARE FOOTAGE 3950.00 2ND FLOOR SQUARE FOOTAGE 900.00 Permit ... �. BUILDING PERMIT -Additional desc . Permit Fee . . . 1805.00 Plan Check Fee 1173.25 Issue Date . . . . Valuation . . ... 432025 Expiration Date 2/26/08 Qty .Unit Chargee Per, : Extension BASE FEE 639.50 333:00 3.5000 THOU -BLDG 100,001-500;000 1165.50 Permit . . ELEC-NEW RESIDENTIAL Additional desc. Permit Fee 223.75 Plan Check Fee 55.94 Issue Date Valuation 0 . Expiration Date 2%26/08 Qty. Unit Charge, Per Extension - BASE FEE 15.00 4850..00 .0350. ELEC NEW RES - 1. OR 2 FAMILY "169.75 1200.00 : .0200 ELEC GARAGE OR NON-RESIDENTIAL 24.00• 1.00 15.0000 EA ELEC,TEMPORARY POWER POLE 15-.00. Permit GRADING PERMIT Additional desc . Permit Fee 15.00 `Plan Check Fee '. .00 Issue Date . . . . Valuation 0 Expiration Date .'2/26/08' S Qty Unit Charge Per Extension BASE FEE 15.00 Permit MECHANICAL Additional desc . i LQPERMIT - LQPERMIT Application Number . . . . . 07-00001691 Permit . . . . . . MECHANICAL Permit Fee 214.50 Plan Check Fee 53.63 Issue Date Valuation . . . .0 Expiration Date 2/26/08 ' Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 11.0000 EA MECH FURNACE >100K 33.00 "- 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 3.00" 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 3.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 49.50 8.00 6.5000 EA MECH VENT FAN 52.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit PLUMBING Additional.desc '. Permit Fee267.75 . Plan Check Fee 66.94 Issue Date . . Valuation .... 0 Expiration Date.. 2/26/08 Qty Unit Charge Per Extension, BASE FEE - •15.00 28.00 6.0000 EA PLB FIXTURE 168.00 •1.00 15.0000 EA -` PLB BUILDING SEWER 15.00 4".00 6.0000 EA PLB ROOF -DRAIN 24.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9,0000 EA PLB LAWN 'SPRINKLER SYSTEM .9.00 15.00 .7500 .EA PLB GAS PIPE >=5 11_25 1.00 15.0000 EA PLB GAS METER 15.00 --------------------------------------------------------- Special Notes and Comments -------- 4,850SF DWELLING/V.-NR/RES"-3/CLASS A -FR 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY CODES. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL AND SPA"OR DRIVEWAY APPROACH. August 28, 2007 4:19:07 PM AORTEGA ------------------------------------------------------- Other Fees . . . . . . . . ART IN PUBLIC PLACES -RES 580.06 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 117..33 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 LQPERMIT Application Number . . . . . 07-00001691 ------------------------------------------------------------ :;' Other Fees . . . . . . DIF PARK MAINT FAC.- RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 43.20 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid. Credited Due Permit Fee Total --- 2526.00 -----------------------.------- .00 .00 2526.00 Plan Check Total "1349.76 500.00 .00 849.76 Other Fee Total 5230.59 .00 .00 5230.59 " Grand Total 9106.35 500.00 .00 8606.35 LQPERMIT - Builaing Address Or T-iht 4 4 Q" P.O. BOX 1504 C h IQ ill7t,4e 78-495 CALLE TAMPICO LA OUINTA, CALIFORNIA 92253 Mailing-V3bSUN-� I`<X77 Address itY ZITeb5/owvalt rO Add C* Y Z��% 3 Tel 7 56 tate Lic. r L City & Classif. Lic. # Designer er r� Designer GC�/i�ynr Ar�ssr r r \ Tel. �It ffq:L < Iinto,?q� LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Divi ' 3 th siness and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, atter, improve, demolish, or repair any structure, prior wits Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by -any applicant ifor a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). l: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) 1'1 1, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law doesnot apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 11 1 am exempt under Sec. B. & P.C. for this reason Date���l Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800. Labor Code.) Policy No. Company r7 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above• mentioned property for inspection purposes. Signature of aOplicant Date Mailing Address City, State, Zip o-7- /(oql APPLICATION ONLY LDING: TYPE'CONST.V_OCC. GRP , Number 777- 210 - 0' l Legal Description nn Project Description l 1� Sq. Ft. g§() No. No. Dw. SizeStories Units New.A, Add ❑ Alter ❑ Repair ❑ Demolition ❑ SFX PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 424=, INV Const. a Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure t TOTAL A Q1 r, REMARKS PT. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION t Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 - Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA:. AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: - MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: - INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence�is;aftlieaHideaway Date: August 30, 2007 Owner's Name: Hideaway JFC Phone No. 567-2066 Project Address: 53-095 Via Chiante La Quinta, CA Project Description: 1 SFD APN: 777-210-011 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 4,850 sq. ft. Certification of Applicant/Owners: The person signing'certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: Augus6 30, 2007 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code , Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 4,850 Amount per Sq.Ft. $3.48 Amount Collected $16,878.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst: Supt., Support Services t AXCertificate issued by: Elvira Mattson, Signature: ' % NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. M V:c/mydocs/devfees/certificate of compliance form updated 3-2007 3/9/07 i`'ANOE COAST TITLE CO. DOC' # 2007-0333358 - .05/18/2007 08:00A Fee:10.00 . - Page 1 of 2 Doe T Tax Paid RECORDING REQUESTED BY: ^ '. z Recorded in Official Reeords The Heritage Escrow Company �`� County of Riverside Larry W. Ward County Clerk 8, Recorder Assessor,i AND WHEN RECORDED MAIL TO: r . ! AND MAIL TAX STATEMENT TO: III II IIIIIIII VIII 1111111111111111 Hideaway JFC 197v LLC y IIIIIIIIIII 78365 Hwy ------- La Quinta, CA 92253— s R U PAGE SIZE DA MISC LONG RFD COPY n i Order No. 852844-10 1/ EXAM Escrow No. 204 -10735 -KW ` r M A L 465 426 CO NCOR 'S NCHG / r Parcel No. 777-210-011 GRANT- , DEED • ', ' � r THE UNDERSIGNED GRANTORS) DECLARE(S) THAT. DOCUMENTARY TRR �S� ER TAX ISS` $ Q49 X computed on full value of property conveyed, ort+rne Qf sale• - -- computeds�rl.full value._I.ess liens_or.encua>rancPsri+n9 t� ,. --- X Cit of La Quinta - unincorporated area: r T y, ' FOR A VALUABLE CONS IDERATION Jeceipt of which is hereby acknowledged, Scott Zimmerman and Kimberly Zimmerman, husband and wife herebyGRANTS toHideaway�JFC 197LLC, a California.Limited Liability Company - the.following described real property in the County of Riverside, State of California: State of Lotivers 197�of amended Tract No. 29894-2; in the Payof e Paa Quinta, County of ge(s) TThrough 88, inclusive of Maps, in the California," as per map recorded in Book 327, g O y Office of the County Recorder of said County.. Date F ruary 22, 2007 .�.. . ' Kimbe y i merman Scott imer n _ STATE OF CALIFORNIA -- a` .r }SS . -- ' . COUNTY OF } NJ On 2 — 2-4o'- .before me, a Notary Public'in and for said County and State, personally appeared odwaer- personally known to me { �) t be the persons) whose names) U/are subscribed to the within instrument and - acknowleies), and dged to me that he/sf�e/they execument thea eeson(s in oefthe entity upon behalf f./their authorized ( which the that by hisA4edtheir signature(s) on the Inst P person(s) acted, executed the instrument. t a WITNESS my hand -and official'seal PAI?LLA ANN JOHNSONL r ' Signature� r I r, ut: + _ E ..os R y.,. Go 61y Gcr„m. apitns h;:rii9,`1000� Page 1 of 1 , i " - � " � � 4 - ^' 4 ' '�. •. ' a z .- � a See r , r:. , August 14, 2007 r r ,- i,, ; a%'n , ,r' Mr. Greg Johnson 78-365 Highway 111; Suite 177 t• ' *r ,' ,.` La Quinta, CA 92253 e .f • 'f'• ') is ; .3, .� - '' ' •' ' Re:3Hideaway Owners Association, Final Design Review 9=2 Lot 197/ 53095 Via Chiante - Dear Mr. Johnson , s. "<' •- ; . The Hideaway Design Review Committee_met to discuss your'second _submitta1 of Final Design" - plans for your lot 197 on Via Chiante The plans were approve - or. const etion to begin ' provided the following items are addressed prior to the setback inspectio- n``- 1. No detail was provided, on. rafter tails andaoutrigger beams and'.how they connect to the trusses. 2. Please clarify the thickness of the lattice and the material that will be used. ^- 3; The rafter,tails overhang materials. 4. The plans will need to be- submitted and stamped by a licensed architect. r 5. Any exposed and"infinity'edge materials must betsubmitted for DRC approval.. ' J 6. ;.• Your designer measured from the finished floor, not the pad height. The ridges are ` showing at 24'6" above the pad which is too higli. e ' 7.. Specifications are needed'on the plans -to`=show the -exterior wall material colors, • including trim, accent colors, roof colors..; ' • 8. All site development details -will need to be providedfor DRC review prior to the '. setback inspection: - ` -Any deviation from the Design Guidelines must be submitted with a request for Variance. . If a design element ; is ,riot . presented as,- a Variance: request and the committee F. inadvertently overlooks it during the' review' process` it .will be the design team's ~` responsibility to make modifications at a later date if .requested by the Design Review v Committee' We look.forward to,working,with you further on -the development of your home. Please contactMindy Gutierrez at (760) 393-5211 to schedule the. preconstruction • r meeting • y i Sincerely, . -'' , : ` 4 •. .• "' * Hideaway sign Review Committee '" ;t ' �, , `" ` . _.`y- _. - - - _, it ' - -`�• , +, „!' " �' • cc: Studio Linea, DRC file' • �^;* 1- . 3 � .. J{, y .. • r i 'T ' YY" I � t 1, t T^• • Y f �'.�.+ , I •, ' :;p: <.''• w; gib' s s?ttJ.'i? ; f 7'R.•:`%2 s.: `. STRUC-f URAL • ]. ^aYC< �i�f�aL.}�i41�}.S\.Y '�i.. i<: +5: �:: `i: � -t�•' •. NRON 7. V6-: NXII .2"2'i,Ew.i A: WA P. YXYr i97 DEAR 6"RE-0 .. ':: +.`'s 3 4� .\ €.i £3'3l3L.i5: ,.%TC'•,i� .-: .,) -' iiY C>JNi7 <, :f,..C, I'lDNAf.n_wY. �.''.;'�u ;. (,jF • C WS ✓��i..il":VEE T'. A F. .M1t�'F:iia�„�^�z:IU:ia.<..` C�3�'v S^•:�,.,-wl�i {. 7t !.•,�, i f.:. f:, 1. �.€S.ti::;: �3�� }�: f.'i: •S'.€s`� i. .. �9 '€'kf 07 R S.-I" I.!€..'. F fit 1# `' iti <:� Y<\f€.'s; t:�t:t€�:tt:€��r':�I�;.��.i��.F` J:r�i��>.3 �`: + �i •f:�: s;3€-�:':i<'Tr: , 7n AND D' AAT T f.S SUCH AS •��:?��;T�;v:<r 5 ,r.€ S µ €'< >.€z:3€'�,i�t3i�":��'��•�:xt �. Te3i" �`¢::t�';€:�_: ��'I:,d.`.��,.i�€:�£'�1� �<t���; �•s:�ii-'C�, € QR- T,€MSRa:3(Ois1#<< ; T'N+s1. ``33jj 5y C R•�'�. . r � " � ..rte _-- _ .A 1-01 Certificate of Occupancy.-....: . Td4t 4 G OF T19� = Building & Safety Department This Certificate is issued pursuant to the requirements ,of Section 109 of the California Building k . Code, certifying ..that, at the time of issuance;. this structure. was in compliance with the provisions : of the' Building Code and the various ordinances_, of the City regulating building construction and/or use. BUILDING ADDRESS: 53-095 VIA CHIANTE Use classification: SINGLE FAMILY DWELLING Building Permit No:: 07-1691. Occupancy Group: R-3 � -Type of. Construction: VN' Land Use Zone: RL Owner of Building: HIDEAWAY JFC Address: 78-365 HIGHWAY 111 #177 - City, ST, ZIP: LA QUINTA, CA. 92253 By: STEVE TRAXEL ` Date: MARCH 24 2010 Building Official - POST IN A CONSPICUOUS PLACE Title 24 Report for: Hideaway /,Lot #197 197 Via Chiante La Quinta , CA 92253 f r C/� Project Designer: �� & SAFE, FC ��� oFP r Studio Linea R CpNSTR 4e® 57-770 Black Diamo DA. VCT/pN La Quinta CA 922 3 a (760) 899-3368V�_,._ Report Prepared By: C.J. McFadden BREEZE AIR CONDITIONING ` 75-145 ST. CHARLES PLACE PALM DESERT, CA 922111ZBCF1VBD (760) 346-0855 FEB 2 3 2010 I BY. .t Job Number: ; Date: 2/23/2010 . The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and i. authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. t This program developed by EnergySoft, LLQ- www.ener,gysoft.com. EnergyPro 4:4 by EnergySoft Job Number: User Number: 3665 - µ Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _H.id.eawa_y_/_Lot_#_1.9.7 .H -VA Act. 2/_23/_20_1.0 Project Title OPAQUE SURFACES Area Date 1.97 V_ia_Chiante-La_Q.u.inta �Azm. Tilt .Roof Project Address 1.,068_ _0.026_ Building Permit # _B.REEZE_AI.R_CQN.DI_T_I_QN.ING (760) 346-0855 Wood_ Documentation Author _0..0.69_ Telephone Plan Check/Date _En.e.r_g_y_P_r_o Wall_ CA--Climate-Zone-1-5 Field Check/Date Compliance Method _13=21_ _R=0..0_ Climate Zone TDV Standard Proposed Compliance _0.069_ (kBtulsf-yr) Design Design Margin Wall_ Space Heating 2.98 5.44 -2.46 -R=21_ _R=0..0_ Space Cooling 66.90 61.39 5.51 Wood_ Fans 9.53 8.75 0.78 0_ Domestic Hot Water 5.93 5.98 -0.05 60_ Pumps 0.00 0.00 0.00 Totals 85.34 81.55 3.78 _0.069_ Building Type Standard: [X-] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SE) 135 deg Natural Gas Area: 904 ft 2 Avg. U: 0.38 Ratio: 22.2% Avg. SHGC: 0.33 BUILDING ZONE INFORMATION Zone Name Floor Area Volume -HVAC-#-1 068 .H -VAC -#.2 .H -VA Act. .HVAC_#_4 Type OPAQUE SURFACES Area 1., 8.0.0 7_7_5 532 1.0,680 -9.,6.0.0 _9,3.00 _5,.320 4.4% Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: 4,075 ft2 n/a ft2 0 ft2 3,175 ft2 10.6 Number of Stories: # of Insulation Act. Zone Type Type Frame Area U -Fac. Cay. Cont. �Azm. Tilt .Roof Wood_ 1.,068_ _0.026_ _R=38_ -FL-0.0-.0_ -0--0 Wall_ Wood_ 1.3.6_ _0..0.69_ _R=21. _R=0...0_ , 45.9.0 Wall_ Wood_ 1.7.0_ _0..0.69_ _13=21_ _R=0..0_ 1.35__9.0 Wall- Wood_ 530_ _0.069_ -R21. _R=0.0_ _225.90 Wall_ Wood_ 1.7.6_ _0.0.69_ -R=21_ _R=0..0_ _31.5_-9.0 .Roof Wood_ 80.0_ -0..026_ _R=38_ _l? 0...0_ 0_ 0 Wall_ Wood- 60_ _0.069_ _R=21. _R=0.0.4.5.90 W all_ Wood- 328_ _0.069_ 13= -21. _R=0.0_ 1.35__90 Wall_ Wood_ 1.60_ _0...0.69_ _R=21. _R=0...0_ _31.5_ 9.0 .Roof Wood_ 7_7.5_ _0...026_ _R=38_ _R=0..0_ -0--0 Wall_ Wood- 569_ _0.069_ _R=21. _R=0.0.4.5.90 Wall_ Wood- 4.0_ _0.069_ -R21. _R=0.0_ 1.35.90 Wall_ Wood_ 1.50_ _0..0.69_ _1321. _R=0..0_ _225.9.0 Wall_ Wood_ 1.92_ _0..0.69_ -R=21.-R=0.0- _31.5__9.0 .Roof Wood_ 532. _0...026_ -R=38_ _R=0.0_ -0--0 Wall_ Wood_ 1.6 - _0.0.69_ -1321. _R=0...0_ 4.5.9.0 Wall_ Wood- 1.96_ _0.069_ -R=21 0. _R-.0_ 1.35__90 .Door None- 24_ _0.600_ _None_ _R=0.0_ 1.35__90 Wall_ Wood- 1.72_ _0.069_ -R=21. _R=0.0_ _225.90 .Roof Wood_ 4.7.3_ _0..026_ _R=38_ _R=0.0_ -0--0 Wall_ Wood_ 1.9.0_ _0..0.69_ _R=21. _13=0..0_ 45__9.0 Wall_ Wood_ 1.53__0..0.69_-R2.1__R=0..0_ 1.35.9.0 Wall_ Wood- 1.68_ _0..0.69_ _1321_ _F3=0...0_ _225__9.0 Wall_ Wood- . 36_ _0.069_ -R=21_ _R=0.0_ -31.5__90 .Roof_ Wood_ 427_ _0.026_ _R=38_ _R=0.0_ -0--0 4.4% Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: 4,075 ft2 n/a ft2 0 ft2 3,175 ft2 10.6 Number of Stories: # of Thermostat Units Zone Type Type -0.26_ Sleeping _SleepingStat_ _0..20_ Living _LivingS.tat_ _0.1.9_ Living -Living.Stat_ -0.].3_ Living _LivingS.tat- ft 1.00 Vent Hgt. Area 8 -nla 8 _nLa 8 _n/.a 8 -n/.a Gains Condition Y / N Status JA IV Reference Location /Comments New .01.A8 Zone -1 New _0.9=A6 Zone 1 New _0.9=A6 Zone -1 New .09=A6 Zone -1 New _0.9=A6 Zone -1 New _01_A8 Zone -2 New .09=A6 Zone -2 New .09=A6 Zone -2 New _0.9=A6 Zone -2 New _0_L -A8 Zone -3 New .09=A6 Zone -3 New _09=A6 Zone -3 New _0.9=A6 Zone-3- New- one_3New _0.9=A6 Zone_3 New .01.A8 Zone_4 New _0.9=A6 Zone_4 New .09=A6 Zone-4- New- one_4New .28=A5 Zone-4- New- one_4New _09=A6 Zone_4 New _01=A8 Zone -5_A New _0.9=A6 Zone_5A_ New .0.9=A6 Zone -5_A New _0.9=A6 Zone -5_A New _09=A6 Zone -5_A New .01.A8 Zone_5_13 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:3 of 34 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _H id.eawa_y_/_Lot_#_1.97 n/a ft2 2/23/_20_1.0 Project Title ft2 Slab on Grade Area: Date 1.9.7_V_i a_C.h.ia nte-La_Q.u.i.nta Average Ceiling Height: 10.6 ft Project Address 1.00 Building Permit # CQN.DI_T_I_QN.LNG Wood_ (760) 346-0855 _0.0.69_ _B.RE.EZE_AI.R Documentation Author _225_ Telephone plan Check/Date _En.e.r_g_y_P_r_o CACi.mate_Zo.ne 1.5 Field Check/Date Compliance Method Climate Zone TDV Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 2.98 5.44 -2.46 Space'Cooling 66.90 61.39 5.51 Fans 9.53 8.75 0.78 Domestic Hot Water 5.93 5.98 -0.05 Pumps 0.00 0.00 0.00 Totals 85.34 81.55 3.78 Percent better than Standard: 4.4% Building Type: [_X] Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (SE) 135 deg Fuel Type: Natural Gas Fenestration: Area: 904 ft2 Avg. U: Ratio: 22.2% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name Floor Area .HVAC -#5 900 0.38 0.33 Total Conditioned Floor Area: 4,075 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 3,175 ft2 Average Ceiling Height: 10.6 ft Number of Dwelling Units: 1.00 Number of Stories: 2 Wood_ # of Thermostat Vent Volume Units Zone Type Type Hgt. Area -81.00 -0.22_ Sleeping _SleepingStat_ 8 -n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont.. Azm. Tilt Wall_ Wood- 2.4.8_ _0.0.69_ _R=211 -R=0-0-4.5_ 90 Wall_ Wood_ 21.9_ _0.0.69_ -R=21_ _120...0_ _225_ 9.0 Wall_ Wood_11_4_ _0.0.69_ -B=21 _IZ0...0_-315__9.0 Gains Condition Y / N Status JA IV Reference Location / Comments DK ❑ New _09_A6 Zone -5 B ❑ New _0.91x6 Zone_5_11 [X_ ❑New _0.9-A6 Zone_5_13 Run Initiation Time: 02/23/10 12:32:50 Run Code: 1266949970 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Paae:4 of 34 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Hideaway / Lot #197 0.76 14 Bug Screen 0.76 15 Bug Screen 2/23/2010 Project Title 0.76 17 Bug Screen _ 0.76 18 Bug Screen Date 19 Bug Screen FENESTRATION SURFACES THERMAL MASS FOR HIGH MASS DESIGN Slab Perimeter Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments New Zone 4 True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments 1_ Window Left_(.S_W) 6..0_ -0.3.8.0_NF_RC.0.3.0 _N R -C -225_ _9.0_ NewSierra_P_acifi.c_Clad_Csmn.t_(.OZ)__Zone 1 2 Window Left (SW) 64.0 0.360 NFRC 0_32 NFRC 225 90 New Sierra Pacific Sldng Dr (4) Zone 1 3 Window Left (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (08) Zone 1 4 Window Left (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (09) Zone 1 5 Window Rear (NW) 48.0 0.390 NFRC 0_28 NFRC 315 90 New Sierra Pacific Frnch Dr (5) Zone 1 6 Window Rear (NW) 24.0 0.350 NFRC 0_38 NFRC 315 90 New Sierra Pacific Fxd Wdw (32) Zone 1 7 -Window--Front--(.SE) 12_5 0389 NFRC 030 _NERC 135_ 90 New Sierra-P-acifi_c Csmdt (15) _Z -one -2 8 Window Front (SE) 6.0 0.350 NFRC 0_38 NFRC 135 90 New Sierra Pacific Fxd Wdw (31) Zone 2 _9_ Window ECont_(SE) -36-0- 0.770 116:A. 0.70 JJBIB 1-35_ 90_ New Custom_Ent_ry_Door (15) Zone_2 1.0. Window Front (SE) 6_0 0380 NFRC 030 NFRC 135_ 90 New Sierra Paoi[c_Csmnt (14) Zorme-2 J Window Rear (NW) 176.0 0.360 NFRC 0_32 NFRC 315 90 New Sierra Pacific Sldng Dr (6) Zone 2 12 Window Right (NE) 3.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (27) Zone 3 1.3. Wio.dow Right_(NE) 3.0 0350_N.ERC 0.3.8 _NERC 45_ _9.0 NewS.ie.rra_P_acifi.c_F-xd_Wdw._(26.) _Zons_3 14 Window Right (NE) 20.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (10) Zone 3 15 Window Right (NE) 20.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (11) Zone 3 16 Window Left (SW) 20.0 0.350 NFRC 0_38 NFRC 225 90 New Sierra Pacific Fxd Wdw (16) Zone 3 17 Window Left (SW) 20.0 0.350 NFRC 0_38 _NERC 225 90 New Sierra Pacific Fxd Wdw (19) Zone 3 18 Window Left (SW) 6.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (20) Zone 3 19 Window Left_(SW) 60.0 0360 NFRC 0 32NFRC _22.5_ 90 New Sierra_Eacific Sdng_Dr (0713) _Zone_3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist.. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen _ 0.76 18 Bug Screen _ 0.76 19 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 THERMAL MASS FOR HIGH MASS DESIGN Slab Perimeter Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 108 None No Insulation 26-A1 New Zone 1 Slab Perimeter 58 None No Insulation 26-A1 New Zone 2 Slab Perimeter 105 None No Insulation 26-A1 New Zone 3 Slab Perimeter 70 None No Insulation 26-A1 New Zone 4 Run Initiation Time: 02/23/10 12:32:50 Run Code: 1266949970 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:5 of 34 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Hideaway / Lot #197 2/23/2010 Project Title Date FENESTRATION SURFACES " True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments .20. Window Rear(NW_ _)_9.0..0_ Exterior Shade Type _0..3.6.0_NERC_0.32 _NERC _31.5_ _9.0_ New -SierraP_acifc_Stdng_Dr_(.0.7_A) _Zone_3 21 Window Right (NE) 48.0 0.390 NFRC 0_28 NFRC 45 90 New Sierra Pacific Frnch Dr (9) Zone 4 22 Window Right (NE) 24.0 0.390 NFRC 0_28 NFRC 45 90 New Sierra Pacific Frnch Dr (10) Zone 4 23 Window Left (SW) 20.0 0.350 NFRC 0_38 NFRC 225 90 New Sierra Pacific Fxd Wdw (17) Zone 4 24 Window Left (SW) 48.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (16) Zone 4 25 Window Right (NE) 10.0 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Csmnt (28) Zone 5 A 26 Window Right (NE,) --J-0-0 -0-3 80 NERC -0-3 0 NFRC 45_ 90 New Sierra Pa_cisc Csmnt (29) _Zorle_5_A 27 Window Right U 6.0 0.380 NFRC 0.30 NFRC 45 90 New Sierra Pacific Csmnt U Zone 5 A 28 Window Left (S_W_) 48.0 0_390 NFRC Q.28 NFRC _22.5_ 90 New Sierra Pacifc ED_ t pr (39) Zon-e_5_8 .29. Window Rigbt_(NE.) -2-5-0 -0-3 80 NERC 00 0 NFRC 45_ 90 NewSierra_Pacifi_c_Csmnt_(24.) -Zone-5_B 30 Window Right (NE) 6.0 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Csmnt (25) Zone 5 B 31 Window Left (SW) 6.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (21) Zone 5 B 32 Window Rear(N_ W -)_6...Q _0.3.8.0_NERC _0.3.0 _NERC _31.5_ _90 N.ew S.ierra_P_acific_Csmnt_(22) _Zone_5_B 33 Window Rear (NW) 6.0 0.380 NFRC 0_30 NFRC 315 90 New Sierra Pacific Csmnt (23) Zone 5 B 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 10.0 9.0 10.0 0.1 10.0 10.0 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen _ 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen _ 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sq (in.) Cap. Cond. R -Val. JA IV Reference .Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Lenqth R -Val. Location JA IV Reference Status Comments Run Initiation Time: 02/23/10 12:32:50 Run Code: 1266949970 EnergyPro 4.4 by Energysoft User Number: 3665 Job Number: Page:6 of 34 Certificate Of Comaliance : Residential (Part 3 of 4) CF -1 R Hideaway / Lot #197 Duct Duct Condition 2/23/2010 Project Title Heating Cooling Location Date Tested? HVAC #1 HVAC SYSTEMS Ducted Attic 4.2 New No HVAC #2 Ducted Ducted Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff - Type Eff Status Type HVAC #1 Central Furnace' 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.58 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvpe In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Studio Linea Address: 57-770 Black Diamond La Quinta , CA 92253 Telephone: (760) 899-3368 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: C.J. McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 (da (signature) te) Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #1 Ducted Ducted Attic 4.2 New No HVAC #2 Ducted Ducted Attic 4.2 New No HVAC #3 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.58 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvpe In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Studio Linea Address: 57-770 Black Diamond La Quinta , CA 92253 Telephone: (760) 899-3368 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: C.J. McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 (da (signature) te) Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R / Lot #197 2/23/2010 Project Title Date Duct Duct Condition HVAC SYSTEMS Location Heating Cooling Location R -Value Status Tested? HVAC #4 Ducted Ducted Attic 4.2 New Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #5 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER • New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #4 Ducted Ducted Attic 4.2 New No HVAC #5 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2 Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Studio Linea Address: 57-770 Black Diamond La Quinta , CA 92253 Telephone: (760) 899-3368 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: C.J. McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 (signature) �- (dite) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Hideaway / Lot #197 2/23/2010 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on the aaequacy of the special Justmcation ana aocumentation sudmittea. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes a Radiant Barrier. The HVAC System "HVAC #1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC #2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #5" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a nr-MQ provwer using approves testing anaior vermcation metnoos. Plan Field The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #5' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Paae:9 of 34 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ +§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ 1§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ . apply to exterior mass walls). *§ 150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent U -factor: d . ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have:. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, Flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor , ❑. ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El ❑ ElCF-6R Form: § 11.6-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage: ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification: 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified.by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating -and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated With an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A: ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight; moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 10 of 34 W Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment El ❑ J C LN LJ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric 2. System is installed with: § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ a. At least 36" of pipe between. filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑ ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 11 of 34 Residential Kitchen Lighting Worksheet - WS -5R Hideaway / Lot #197 2/23/2010 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (2) 2 ft Fluorescent T8 Elec Yes X No 33.0 x 1 33 or 16w Fluorescent Undercabinet T5 Yes X No 16.0_ x 4 64 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or { Yes No x = or Yes No x = or Yes -No x = or Yes No x = or Yes No x - or Yes No x = or Yes No _x = or Yes No x - or Yes Nox = or Yes No. o x _ or Yes No x = or Total A: 97 B: 0 COMPLIES IF A >_ B YES R NO ❑ C/ op 8DING App sAFE7Y D FO C �0 `/46 ONSTRUC DATE Z 13 r/pN /D eY1/ I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 12 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway/ Lot #197 2/23/2010 SYSTEM NAME FLOOR AREA HVAC #1 1,068 Number of Systems 1 Heating System Output per System 58,000 Total Output (Btuh) 58,000 Output (Btuh/sgft) 54.3 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons). 3.9 Total Output (Btuh/sgft) 44.0 Total Output (sgft/Ton) 272.7 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.50 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 546 13,366 1,900 402 14,957 0 1,917 1,698 0 0 0 0 0 0 0 0 0 1,9171 1,698 77 200 ' 1,900 18,353 PSA2BD / PGCI RA (4 Ton) 13 SEER 40,644 0 58,000 Total Adjusted System Output 40,644 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.0°F 105.0°F 105.0°F O Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 104.0 °F 1600 cfm ROOMS 69.0 OF 70.0 OF Return Air Ducts [COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0 / 77.6 OF 79.1/63.0 OF 55.0 / 53.7 OF 55.0 / 53.7 OF O Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 56.1 / 54.1 OF 1600 cfm 42.3% R.H. ROOMS 79.1/63.0 °F 78.0 / 62.6 OF Return Air Ducts"R'( I 4.4 User Number: 3665 Job Number: 13 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway / Lot #197 2/23/2010 SYSTEM NAME FLOOR AREA HVAC #2 800 26.0 OF "> 0 Outside Air 0 cfm 69.3 °F 11.0 / 77.6 OF Outside Air 0 cfm 79.0/62.8 °F RICS 69.3 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply°Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 602 14,746 1,624 329 12,259 0 2,115 1,392 0 0 0 0 0 0 0 0 0 2,115 1,392 18,976 1,624 15 043 PSA2BD / PGC1 RA (5 Ton) 13 SEER 50,022 0 86,000 Total Adjusted System Output 50,022 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am am Ter 105.0 °F Heating Coil YCHROMETRICS (Airstream Supply Fan 2000 cfm 105.0 OF Supply Air Ducts 104.3 of ROOMS 70.0 OF �% Return Air Ducts 4 79.0/62.80F M 55.0/53.70F - 55.0 / 53.7 OF Cooling Coil O Supply Air Ducts Supply Fan 56.0/54 . 1 OF 2000 cfm. 41.9% R.H. ROOMS 78.0/62.5°F Return Air Ducts � I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 14 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway / Lot #197 2/23/2010 SYSTEM NAME FLOOR AREA HVAC #3 , . 775 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD, COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 58 14,216 1,598 383 14,253 0 2,039 1,618 0 0 0 0 0 0 0 0 0 2,039 1,618 18,2951 1,598 17,490 PSA26D / PGC1 RA (4 Ton) 13 SEER 40,614 0 58,000 Total Adjusted System Output 40,614 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Q-IEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 of 69.0 of 105.0 of 105.0 of Outside Air 0 Supply Air Ducts 0 cfm Heating Coil Supply Fan 104.0 of 1600 cfm - ROOM S 69.0 of ( 70.0 of Return Air Ducts I COOLING SYSTEM PSYCHROMETRI 111,0/77.6OF Outside Air 0 cfm 79.2/62.9 of 79.2 / 63.0 of 55.0 / 53.7 of 55.0 / 53.7 of O Supply Air Ducts Cooling Coil Supply Fan 56.2 / 54.2 of 1600 cfm 42.1% R.H. ROOMS 78.0 / 62.5 of Rcfiirn Air n intc I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 15 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE . Hideaway / Lot #197 2/23/2010 SYSTEM NAME FLOOR AREA HVAC #4 532 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sqft) 67.7 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 45.1 Total Output (sgft/Ton) 266.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.50 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 68.7 OF Outside Air 0 cfm 68.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 542. 13,275 1,348 262 9,753 0 1,904 1,107 0 0 0 0 0 .0 0 0 0 1,904 1,107 17,083 1,348 11 967 PSA213D / PGC1 RA (2 Ton) 13 SEER 20,913 0 36,000 Total Adjusted System Output 20,913 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Heating Coil Supply Fan 800 cfm 105.0 of —),b Supply Air Ducts 103.7 of ROOMS 70.0 of Return Air Ducts wz I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 80.2/63.5OF 55.0/53.6 OF 55.0/53.6 OF O Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 57.2 / 54.5 of 800 cfm 42.7% R.H. ROOMS 80.2/63.5 of 78.0 62.7 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 16 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway / Lot #197 2/23/2010 SYSTEM NAME FLOOR AREA HVAC #5 900 EATING SYSTEM 26.0 of Outside Air 0 cfm 69.1 of SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 582 14,257 2,527 278 10,368 0 2,045 1,177 0 0 0 0 0 0 0 0 0 2,045 1,177 TOTAL SYSTEM LOAD 18,347 2,527 12,722 HVAC EQUIPMENT SELECTION PSA26D / PGC1 RA (3 Ton) 13 SEER 30,486 0 43,000 Total Adjusted System Output30,486 0 43,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am (CHROMETRICS (Airstream Ter 69.19F 105.OoF Heating Coil Supply Fan 1200 cfm 105.0 of Supply Air Ducts 104.1 of ROOMS 70.0 of �%Return Air Ducts `i (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0/77.6OF 79.6/63.5OF 55:0/53.7OF 55.0/53.7OF O Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 56.6/54.3 of 1200 cfm 43.3% R.H. ROOMS 79.6/63.4 of 78.0 / 62.9 of Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page 17 of 34 TITLE 24 REPORT Title 24' Report for; , Hideaway / Lot #197 197 Via Chiante La Quinta , CA 92253 * ` Project Designer: Studio Linea 57-770 Black Diamond La Quinta , CA 92253 (760) 899-3368 Report Prepared By: C.J. McFadden C.M. Energy Consulting ' 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014- CITY OF LA QUINTA ' BUILDING & SAFETY DEPT. ` APPROVED FOR CONSTRUCTION DA BY 'Job Number:' , The EnergyPro computer program has been used to perform'the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number:' User Number: 1086 TABLE OF CONTENTS EnergyPro 4.3 by EnergySoft Job Number: User Number: 1086 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _H.ide.away_/_ of_#_1.97 R-0.0 45 90 Wall_ Wood- AZO 0.069 R_21 R-0.0 135 -90 7/20/200-7 Project Title Wall_ Wood 116 nn69R_21 X0.0 315 90 .Roof Wood_ a0.0_ 0.026 R-38 Date 1.9 ZV_ i a_Chian te_La_Quinta R-n.n 45 9.O Wall_ Woad_ i9a 0062R_91 R-0 o 13.9 -_90 Wall_ Wood- -x.60 0069 _R21 Project Address .Roof Wood_ _-zZ5 o 026 R-38 _R=O.O_ _0 - 0 Wall_ Wood- 569_ On 9_ R_21 Building Permit # OM naecw_ orlS.11tng R_0 n _135 -90 Wall_ Wood_ _x.5.0_ -0-00 _R21 (760) 346-8014 plan Check/Date ei R-0.0 Wall_ Wood_ 168_ _0069_ R-21 R-0.0 45.90 Wall- Wood- X96_ _0069_ R-21 _Ener_g_y_P_ro .Door. None- 24 _0-6.0D_ _Nnne R -0L_ 135 _90- CA CliMate 70TIB-15 X0.0.925 90 Field Check/Date Compliance Method Wall_ Wood_ X0.0 _0..0.62 R_21 _B_-0_0_ 45 90 Climate Zone --R-AD- -9Il TDV Standard Proposed Compliance Roof_ Wood_ 27_ X026. _13_38 _ kBtu/sf-yJr Design Design Margin Space Heating 2.98 5.44 -2.46 Space Cooling 66.90 61.39 5.51 Fans 9.53 8.75 0.78 Domestic Hot Water 5.93 5.98 -0.05 Pumps 0:00 0.00 0.00 Totals 85.34 Percent better than Standard: Building Type: X Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: 81.55 ❑ Addition ❑ Existing + Add/Alt (SE)135 deg Natural Gas Area: 904 ft2 Avg. U: 0.38 Ratio: 22.2% Avg. SHGC: 0.33 BUILDING ZONE INFORMATION Zone Name Floor Area Volume -HVA- C_#1 068 li1/AC2 aoo HyAC #3 770. 1JYAC #4 532 OPAQUE SURFACES 11fl n A t in 680 -9,SIlIl 9,300 5,320 nsu a to c . Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roo.L_ Wnnri 1 O6A_ -n2f3 . R-18 Wall_ Wo d- 136 0.069 R-21 R-0.0 45 90 Wall_ Wood- AZO 0.069 R_21 R-0.0 135 -90 Wall_ Wood _530- n n69 R_21 R-0 n 725 g0 Wall_ Wood 116 nn69R_21 X0.0 315 90 .Roof Wood_ a0.0_ 0.026 R-38 R-0.0 _0_ 0 Wall Wnod_ 60_ n 0639 R-21 R-n.n 45 9.O Wall_ Woad_ i9a 0062R_91 R-0 o 13.9 -_90 Wall_ Wood- -x.60 0069 _R21 _R-00_ 315 -90 .Roof Wood_ _-zZ5 o 026 R-38 _R=O.O_ _0 - 0 Wall_ Wood- 569_ On 9_ R_21 R-0.0 45 90 Wall_ Wood_ 40 n nal -R_21 R_0 n _135 -90 Wall_ Wood_ _x.5.0_ -0-00 _R21 X0_0 -225 _9.0 .Wall_ Wood_ 192 0.069 R_21 R-0 0 315_ go _Roof Wood_ _532 X1026_ R-38 R-0.0 Wall_ Wood_ 168_ _0069_ R-21 R-0.0 45.90 Wall- Wood- X96_ _0069_ R-21 R-0 0 1,145 q0 .Door. None- 24 _0-6.0D_ _Nnne R -0L_ 135 _90- Wall_ Wood- 172 _0060 R_2.1 X0.0.925 90 .Roof Wood_ -4.73 _0026 R-38 R-0.0 0 0 Wall_ Wood_ X0.0 _0..0.62 R_21 _B_-0_0_ 45 90 .Wall_ Wood_ 1.5.3_ U69- R-21 --R-AD- -9Il Wall_ Wood_ 1.6.8_ 0.06.9_ R_21 X00_ 225 -9Il Wall_ Woo.d_- 36_ _01162 R-21 R-0 0 -315_ 90 Roof_ Wood_ 27_ X026. _13_38 _R-_0_0_ -o_ 0 3.78 4.4% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: Inn - 1 # of 7one1 Thermostat Units Zone Type . Type -0.26_ Sleeping -SteepingStnt_ -0-20- Living _Llving.Stat 0.19 Living LiyiogStat_ 0_13 Liviag Li agStat 4,075 ft2 n/a ft2 0 ft2 3,175 ft2 10.6 ft 1.00 Vent Hgt. Area 8 -nLa 8 ----o/.a 8 La 8 _oLa Gains Condition Y / N Status JA IV Reference Location / Comments New Q1 -A8 Inn - 1 New 09-A6 7one1 New 09-A6 Zone 1 New MAR 7one 1 New 096 7one 1 New DJ -AS Zone 2 New 09-A6 Znne 2 New 09-A6 Zone 2 N.ew 0-9-66 Zone 2 _- New 01-A8 Zane_3 Near 09-A6 Znnp 3 New MAR 7one 3 Near DR --A6 Zone - 3 -New Q9=A6 Zane -3 New _0]-A8 7one 4 Near 09-A6 Zone 4 Near 09-A6 Zone_4 New 2A -A--5 7one_4 New 09--A6 Zone 4 N.ew 0L -A8 Zone 5 A Ne -w 09=A6 Zone -5 A - New 0.9- Zoae� A Neap 096 Zoned A New -09_2.6 Zone 5 A New OL -A8 Zone -9-R Run Initiation Time: 07/18/07 17:26:34 Run Code: 1184797594 EnergyPro 4.3 by EnergySoft User Number. 1086 Job Number: Page:3 of 34 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _Ni.de.awayJ_L.ot#19.7 71201 7 Project Title 1.97 ViaChiante—La- uinta Date Project Address Building Permit # C.M.consulting (760) 346-8014 plan Check/Date Documentation duthor Telephone' _Eaerg_yPgo CJ-ClimateZone-5 Field Check/Date Compliance Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.98 5.44 -2.46 Space Cooling 66.90 61.39 5.51 Fans 9.53 8.75 0.78 Domestic Hot Water 5.93 5.98 -0.05 Pumps 0.00 0.00 0.00 Totals 85.34 81.55 3.78 Percent better than Standard: 4.4% I BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type:. [ Single Family ❑ Addition Total Conditioned Floor Area: 4,075 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (SE) 135 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 3,175 ft2 Fenestration: Average Ceiling Height: 10.6 ft Area: 904 ft2 Avg. U: 0.38 Number of Dwelling Units: 1.00 Ratio: 22.2% Avg. SHGC: 0.33 Number of Stories: 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .171 -VAC, #5 ann R 1nn�nn n 92 Seeping—_ _SleepingStat_ 8 —n[a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall_ Vllood— 948 n o69 _R21 Wall_ Wood_ X19 0.069 R-21 Wall_ Wood_ 114 O.069 R-21 Gains Condition Y / N Status JA IV Reference Location / Comments F-1 F-1 F ❑ ❑❑ ❑❑ F-1 F-1 F-1 F-1 00 F] F-11 F-1 F-1 New Q9 -A6 Zones R blew 09-A6 Zone.'; R New O9 -A6 Zcwe 5 B EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:4 of 34 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Hideaway / Lot #197 7/20/2007 Project Title Date FENESTRATION SURFACES # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen True Cond. Location/ # Type Bug Screen Area U -Factor' . SHIS Azm. Tilt Stat. Glazing Type Comments _L Windcw.__Lefi_(.SW)6.0_ _0.3.W NFRC _0..30 -NERC 625_ _90_ New Sierra -Pacific C1adCsmoi(07-)-zone 5 2 Window Left (SW) 64.0 0.360 NFRC 0_32 NFRC 225 90 New Sierra Pacific Sldng_Dr (4) Zone 1 3 Window Left (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (08) Zone 1 4 Window Left (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (09) Zone 1 5 Window Rear (NW) 48.0 0.390 NFRC 0_28 NFRC 315 90 New Sierra Pacific Frnch Dr (5) Zone 1 6 Window Rear (NWS 24.0 0.350 NFRC 0_38 NFRC 315 90 New Sierra Pacific Fxd Wdw (32) Zone 1 7 Window Front (SE) 12.5 0.369 NFRC 0.30 NFRQ 135 90 New Sierra Pacific Csmnt (J-5) Zone 2 8 Window Front (SE) 6.0 0.350 NFRC 0.38 NFRC 135 90 New Sierra Pacific Fxd Wdw (31) Zone 2 9 Window Front E) 36.0 0379116_A_Q.79 1168 135�9 New Custom Entry Door (15) Zone 2 1Q Window Front (SE) 6.0 9380 NFRC 0.30 NFRC 135_ __9Q New Sierra Pacific Csmnt (14) Zone 2 11 Window Rear (NW) 176.0 0.360 NFRC 0_32 NFRC 315 90 New Sierra Pacific Sldng Dr (6) Zone 2 12 Window Right (NE) 3.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (27) Zone 3 3. _N_indow Bight (NyE) _3.00-3�5, NFRQ_QA NFRC 45_ _9k New -Sierra Pacific Fxd Wdw --Zone_3 14 Window Right (NE) 20.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (10) Zone 3 15 Window Right (NE) 20.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd Wdw (11) Zone 3 16 Window Left (SW) 20.0 0.350 NFRC 0_38 NFRC 225 90 New Sierra Pacific Fxd Wdw (16) Zone 3 17 Window Left (SW) 20.0 0.350 NFRC 0_38 NFRC: 225 90 New Sierra Pacific Fxd Wdw (19) Zone 3 18 Window Left (SW) 6.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (20) Zone 3 19 Window Left( 60.0 0.369NF1RQ 0.32C5 90 New Sierra Pacific Sldng Dr (078) Zone 3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 Ti Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 _ THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Slab Perimeter 108 None No Insulation 26-A1 New Zone 1 Slab Perimeter 58 None No Insulation 26-A1 New Zone 2 Slab Perimeter 105 None No Insulation 26-A1 New Zone 3 Slab Perimeter 70 None No Insulation 26-A1 New Zone 4 _ Run Initiation Time: 07/18/07 17:26:34 Run Code: 1184797594 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:5 of 34 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Hideaway / Lot #197 7/20/2007 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments .20. Wiodoy_ReaL(UW_) _9.0_0_ 0_16 NERC -0-32 32 -NFRC _315_ -9.0- New Sierra_2acific-Sldno Dr (07A)_-ZQae-3 21 Window Right (NE) 48.0 0.390 NFRC 0.28 NFRC 45 90 New Sierra Pacific Frnch Dr (9) Zone 4 22 Window Right (NE) 24.0 0.390 NFRC 0_28 NFRC 45 90 New Sierra Pacific Frnch Dr (10) Zone 4 23 Window Left (SW) 20.0 0.350 NFRC 0_38 NFRC 225 90 New Sierra Pacific Fxd Wdw (17) Zone 4 24 Window Left (SW) 48.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (16) Zone 4 25 Window Right (NE) 10.0 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Csmnt (28) Zone 5 A ZQ Wi_ cow Rigfjt_(NE) 10.0 0.38 NFRC 0,34 1NFRC 45 9Q New Sierra Pacific C$mnt (29) Zgne 5 A 27 Window Right (NE) 6.0 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Csmnt (30) Zone 5 A 2$ W'Indow Left (SW) 48.Q 0_390 NFRC 0.28 1NFRC 225 90 New Sierra Pacific Frnch Dr (39) Zone 5 A 29 3Q Window Right (NE) 25.0 0_380 NFRC 0.30 JCC 45 Window Right (NE) 6.0 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Csmnt (24) 90 New Sierra Pacific Csmnt (25) Zone 5 B Zone 5 B 31 Window Left (SW) 6.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Csmnt (21) Zone 5 B 32. Wiod9A__Rear (N= 6..0 038 r1FRC -0-M NERC, _315_ -.O New Sief[a_Enific,Csmnt (22) _7one_5B 33 Window Rear (NW) 6.0 0.380 NFRC 0_30 NFRC 315 90 New Sierra Pacific Csmnt (23) Zone 5 B 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING window Overhand Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 10.0 9.0 10.0 0.1 10.0 10.0 Ti Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 _ 24 Bug Screen 0.76 _ 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen _ 0.76 31 Bug Screen 0.76 32 Bug Screen _ 0.76 33 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page:6 of 34 i Certificate Of CornMiance : Residential (Part 3 of 4) CF -1 R Hideaway / Lot #197 Tank Energy Duct Duct Condition 7/20/2007 Project Title Heating Cooling Location. Date Tested? HVAC #1 HVAC SYSTEMS Ducted Attic 4.2 New No HVAC #2 Ducted Ducted Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS . ' Rated Tank Energy Duct Duct Condition Ducts Location Heating Cooling Location. R -Value Status Tested? HVAC #1 Ducted Ducted Attic 4.2 New No HVAC #2 Ducted Ducted Attic 4.2 New No HVAC #3 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS . ' Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/h r) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.58 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP TVDe In Plenum Outside Buried Insulation REMARKS • COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Studio Linea Address: 57-770 Black Diamond La Quinta , CA 92253 Telep ne: 760 899-3368 Lic. #: c, d- (si at (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: C.J. McFadden Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive Suite 204 Palm Desert, CA 92260 Telephone: 760 346-8014 b% (signature) (date) EnergvPro 4.3 by EnerovSoft User Number: 1086 Joh Numher Pnoe- 7 of 34 ! Certificate Of Comaliance : Residential (Part 3 of 4) CF -1 R Hideaway / Lot #197 Duct Condition Ducts Location Heating Cooling Location R -Value Status 7/20/2007 Project Title 4.2 New No HVAC #5 Ducted Ducted Attic Date No HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC #5 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #4 Ducted Ducted Attic 4.2 New No HVAC #5 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum- Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: C.J. McFadden Title/Firm: Studio Linea Title/Firm: C.M. Energy Consulting Address: 57-770 Black Diamond Address: 72-925 Fred Waring Drive Suite 204 La Quinta , CA 92253 Telep ne: 760 899-3368 Lic. #: 77(s' nat ) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Palm Desert, CA 92260 _ Telephone: (760) 346-8014 (signature) d e) i EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:8 of 34 . Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Hideaway / Lot #197 7/20/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The HVAC System "HVAC #1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC #2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #5" must meet all CEC Criteria for a Zonallv Controlled system servinq only Sleepinq Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. I The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #5' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. I EnergyPro 4.3 by EnergvSoft User Number: 1086 Job Number: Page:9 of 34 I Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with, an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Check or initial applicable boxes or check NA if not applicable and included with the DESCRIPTION ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures +§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. "' ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ y§ 150(c): Minimum R-13 wall insulation in wood framed walls orequivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire'opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning, gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements. specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the•insulation alone without facings"no greaterthan 0:3%, water vapor ❑ . ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets in installation quality, standards. -Indicate type and include ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ' ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label.with certified LI -Factor, certified Solar Heat Gain " ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed: ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1506): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be,extemally'wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ �I ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B.. l 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table,150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. i ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,' ❑ L El and wind. j 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ i i entirely in conditioned space. i 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. U ❑ ❑ l I EneravPro 4-3 by EnerovSoft User Number, 1086 -Inh Numher Pane• 1n of 34 l Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch', the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than El El 1:1sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating: b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1'19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page: 11 of 34 Residential Kitchen Lighting Worksheet WS -5R Hideaway / Lot #197 7/20/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires, as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be, installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 16w Fluorescent Undercabinet T5 Yes X No 16.0 x 5 80 or 240 Watt Chandelier Yes No XI 240.0 x 1 or 240 26 Watt CFL Yes X No 26.0 x 12 312 or 35w Low Voltage MR -16 1 No X1 35.0 x 4 - or 140 Yes No x = or 4 Yes No x = or Yes No x = or Yes No x < = or Yes No x = or Yes No x - or ' Yes No x or Yes . No x - or Yes No x = or Yes No x - or Yes No x = or Yes No x - or Yes x or YesI!No x - or Yes I x - or Yes x = or Total A: 392 B: 380 COMPLIES IF A >_ B YES[i] NO ❑ EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 12 of 34 j 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (PROJECT NAME I DATE Hideaway / Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #1 1,068 N Number of Systems 1 Heating System Output per System 58,000 Total Output (Btuh) 58,000 Output (Btuh/sgft) 54.3 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 44.0 Total Output (sgft/Ton) 272.7 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.50 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above aiven at ARI conditions 26.0 OF Outside Air 0 cfm 69.0 OF 69.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 572 13,9941;2,118 411 15,318 0 2,007 1,739 0 0 0 0 0 0 0 0 0 2,007 1,739 18,008 2 118 18,797 PSA213D / PGC1 RA (4 Ton) 13 SEER 40,685 0 58,000 Total Adjusted System Output 40,685 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am 105.0 OF Heating Coil Supply Fan 1600 cfm 105.0 of —� Supply Air Ducts 104.0 of ROOMS 70.0 OF 1% Return Air Ducts `{ ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I 11.0 / 77.6 OF Outside Air 0 cfm i i 79.2 / 63.0 °F 79.2/63.10F . 55.0/53.70F Cooling Coil Supply Fa 1600 cfm 55.0 / 53.7 OF —� Supply Air Ducts Fan 56.2 / 54.2 of f 42.5% R.H. ROOMS"' 78.0 / 62.6 of , h Return Air Ducts 'I _ l EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 13 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway / Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #2 800 EERING CHECKS Number of Systems 1 Heating System Output per System 86,000 Total Output (Btuh) 86,000 Output (Btuh/sqft) 107.5 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 72.5 Total Output (sgft/Ton) 165.5 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 2.50 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions JEATING SYSTEM P 26.0 OF Outside Air 0 cfm 69.3 OF SYSTEM LO Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFMISensiblel Latent 11CFM1 Sensible 6221 15,2161 1,787 3361 12,530 0 2,182 1,4231 0 01 0 0 0 0 0 0 2,182 E:�]A 19,58 1,787 15,375 PSA213D / PGC1 RA (5 Ton) 13 SEER 50,052 0 86,000 Total Adjusted System Output50,052 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.3 OF ® 105.0 °F Heating Coil Supply Fan 2000 cfm 105.0 OF -30Supply Air Ducts 104.3 OF ROOMS 70.0 OF I Return Air Ducts `S i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 79.0 ! 62.9 OF 55.0 / 53.7 OF 55.0 / 53.7 OF _4 Supply Air Ducts Outside Air 0 i0 cfm Cooling Coil Supply Fan 56.0/54.1 °F i 2000 cfm 42.0% R.H. ROOMS 79.0/62.8°F 78.0/62.5°F Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 14 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway/ Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #3 775 KS Number of Systems 1 Heating System Output per System 58,000 Total Output (Btuh) 58,000 Output (Btuh/sqft) 74.8 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 60.6 Total Output (sgft/Ton) 197.9 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 2.06 Airflow (cfmrron) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions :ATING SYST 26.0 OF Outside Air 0 cfm 69.0 OF 111.0 / 77.6 OF Outside Air 0 cfm i I 63.0 °F 69.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensiblel Latent I I CFM I Sensible 599 14,672 1,756 390 14,516 0 2,104 1,648 0 0 0 0 0 0 0 0 0 2,104 1,648 18,8801 1,756 17 812 PSA213D / PGC1 RA (4 Ton) 13 SEER 40,643 0 58,000 Total Adjusted System Output 40,643 OI 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am irstream Temperatures at Time of Heating Peak) 105.0 OF 105.0 °F ^� Supply Air Ducts Heating Coil Supply Fan 104.0 OF 1600 cfm ROOMS 70.0 OF k Return Air Ducts 4 79.2 / 63.0 °F M 55.0/53.70F Cooling Coil Supply Fa 1600 cfm 55.0 / 53.7 of -� Supply Air Ducts Fan 56.2 / 54.2 OF 42.2% R.H. i ROOMS i, 78.0 / 62.6 of ; Return Air Ducts ' ' 1 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page: 15 of 34 j HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway/ Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA , HVAC #4 I 532 ENGINEERING CHECKS =1SYSTEM LOAD �� Number of Systems 1 Heating System Output per System 36,000 i Total Output (Btuh) 36,000 lOutput (Btuh/sgft) 67.7 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 45.1 Total Output (sgft/Ton) 266.0 Air System CFM per System 800 Airflow (cfm) I 800 Airflow (cfm/sgft) 1.50 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent 1, CFM I Sensible 555 13,587 1,456 267 9,933 0 1,949 1,128 0 0 0 01 01 0 0 0 0 1,949 1,128 17 485 1,456 12,188 PSA2BD / PGC1RA (2 Ton) 13 SEER 20,934 0 36,000 Total Adjusted System Output 20,934 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 OF 68.70F 105.0 OF 105.0 OF Q✓`. Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 103.7 ofS 800 cfm ROOM 70.0 of 68.7 of I Return Air Ducts 111.0 177.6 of Outside �'y 0 cfm 80.3 / 63.5 of 80.3 ! 63.5 of 55.0 ! 53.6 of V. z;'r Cooling Coil Supply Fa 800 cfm 55.0 / 53.6 of Supply Air Ducts Fan 57.3/54.6OF 42.8% R.H. ROOMS 78.0 / 62.8 of h Return Air Ducts 'I EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 16 of 34 j HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 7-71 PROJECT NAME DATE Hideaway / Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #5 900 SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible :ATING SYSTEM PSYCHROMETRICS 26.0 OF 69.1 OF 41 Outside Air 0 cfm 69.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 604 14,786 2,710 287 10,673 0 2,121 1,212 0 0 0 0 0 OI 0 0 0 2,121 1,212 19,027 2,7101 13,096 PSA2BD / PGC1 RA (3 Ton) 13 SEER 30,520 0 43,000 Total Adjusted System Output 30,520 0 43,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am :am Temperatures at Time of Heating Peak) 105.0 OF 105.0 OF S I A' D t Heating Coil upp y it uc s Supply Fan 104.1°F 1200 cfm ROOMS 70.0 OF Return Air Ducts I 1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0 / 77.6 OF 79.7 63.5 OF 55.0 / 53.7 OF 55.0 / 53.7 of 1 Supply Air Ducts °. Outside Air 4 , 0 cfm Cooling Coil Supply Fan 56.7 / 54.4 OF 1200 cfm 43.4% R.H. ! ROOMS 76.7 63.5 of 78.0 / 62.9 OF Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 17 of 34 ROOM LOAD SUMMARY PROJECT NAME DATE Hideaway / Lot #197 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #1 1,068 7 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK Ir COIL HTG. PEAK ZONE NAME I ROOM NAME Mult.l CFM ISENSIBLE I LATENT CFM SENSIBLE I LATENT 11 CFM . SENSIBLE Master Bedroom Zone 1 I 1 572 13,994 2,118 572 13,994 2,118 411 15,318 PAGE TOTAL 1 5721 13,9941 2,11811 4111 15,31 TOTAL 1 5721 13,9941 2,11811 4111 15,318 EnergyPro By EnergySoft User Number: User Job Number. Page: 18 of 34 I ROOM LOAD SUMMARY i PROJECT NAME Hideaway / Lot #197 DATE 7/20/2007 SYSTEM NAME HVAC #2 FLOOR AREA 800 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM (SENSIBLE I LATENT CFM I SENSIBLE Zone 2 Great Room 1 622 15,216 1,787 622 15,21 1,787 336 12,530 I 114 '1 i( 1 7 1 !1 1 1 PAGE TOTAL 622 15,2161 1,787I�36I 12,530 ( TOTAL 1 622 15,216 1,78711 3361 12,530 li EnergyPro By EnergySoft User Number. User Job Number: Page: 19 of 34 1 ROOM LOAD SUMMARY PROJECT NAME _ Hideaway / Lot #197 DATE 7/20/2007 1SYSTEM NAME HVAC #3 FLOOR AREA I 775 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult.I CFM (SENSIBLE I LATENT CFM I SENSIBLE I LATENT I CFM I SENSIBLE Zone 3 Dining/Kitchen 1 599 14,6721 1,756 599 14,672 1,756 3901 14,516 i 1 i 1 1 i� PAGE TOTAL F 599 14,672 1,756 3901 14,516 1, TOTAL ( 599 14,672 1,7561 3901 14,516 EnergyPro By EnergySoft User Number: User Job Number: Page: 20 of 34 ROOM LOAD SUMMARY PROJECT NAME Hideaway / Lot #197 DATE 7/20/2007 (SYSTEM NAME I HVAC #4 FLOOR AREA 532 ROOM LOAD SUMMARY I ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM (SENSIBLE LATENT CFM ISENSIBLE LATENT CFM I SENSIBLE Zone 4 Office/Laundry 1 555 13,587 1,456 555 13,587 1 456267F 9,933 I �Ii i I ,r i' I PAGE TOTAL 1 5551 13,587 1,4561 267 9,933 IFi TOTAL 1 555 '13,5871 1,4561 2671 9,933 s EnergyPro By EnergySoft User Number: User Job Number: Page: 21 of 34 ROOM LOAD SUMMARY PROJECT NAME Hideaway / Lot #197 DATE 7/20/2007 SYSTEM NAME HVAC #5 FLOOR AREA ( 900 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM (SENSIBLE LATENT I CFM SENSIBLE I LATENT CFM I SENSIBLE Zone 5 A Guest Bedroom1 1 3161 7,741 1,384 3167,741 1384 151 5.636 � Zone 5 B Guest Bedroom 2 1 288 .7,045 1,327 288 7,045 1,327 135 5,036 i j �I ' I i PAGE TOTAL i 6041 14,786 2,710 287 10,673 t TOTAL 1 604 14,786 F 2,710 287 I 10,6731 1 I I EnergyPro By EnergySok User Number: User Job Number: Page: 22 of 34 ROOM HEATING PEAK LOADS Project Title Date Hideawa / Lot #197 17/20/2007 Room Information Design Conditions Room Name Master Bedroom Time of Peak Jan 12 am Floor Area 1,068 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value Z�T OF Btulhr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 405 Infiltration: IF 1.00 X 1.064 X 1.068 X 10.00 X 0.590 / 601 X 44 =4,914 —Schedule Air Sensible Area Ceiling Height ACH — &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,318 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 23 of 34 1,068.0 X x x X X X X X X X X X 'x X X X X X X X X X X X X X X X X X X X X X X X X X 0.0260 X X x x X x X X X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = 1222 perimeter = 108.0 0.7300 44 3,469 136.0 0.0690 44 413 170.0 0.0690 44 516 530.0 0.0690 44 1,609 6.0 0.3800 44 100 64.0 0.3600 44 1,014 10.0 0.3800 44 167 10a 0,3800. 44 167 176.0 0.0690 44 534 48.0 0.3900 44= 8 24.0 0.3500 44 370 i I Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 405 Infiltration: IF 1.00 X 1.064 X 1.068 X 10.00 X 0.590 / 601 X 44 =4,914 —Schedule Air Sensible Area Ceiling Height ACH — &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,318 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 23 of 34 ROOM HEATING PEAK LOADS Project Title Date Hideaway / Lot #197 (7/20/2007 Room Information Design Conditions Room Name Great Room Time of Peak ,tan 12 am Floor Area 800Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 800.0 x x X x X x x x x x x x x x x x x x x x X x X x, X X X X X x X X X x x X x x x 0.0260 x x x x X x x X X x x x x x x x x x x x X X X x x X x X x x x x x x X x x X x 44 = = = = = = = = = = = = = = = = = = = 915 perimeter = 58.0 0.73001 44 1,8631 60.0 0.0690 44 1821 327.5 0.0690 44 994 12.5 0.3800 44 209 6.0 0.3500 44 92 36.0 0.7700 44 1,220 6.0 0.3800 44 100 160.0 0,0690 44 486 176.0 0.3600 44 2.788 (( I items snown wnn an asterisk denote conduction tnrougn an interior surtace to another room. Page Total: 8,8501 Infiltration: ,-- -100 x 1.064 x 800 x 12.00 x 0.491 / 60] x 44� Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,530 j__EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 24 of 34 �. ROOM HEATING PEAK LOADS -771 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 25 of 34 Project Title Date Hideawa r / Lot #197 7/20/2007 Room Information Design Conditions Room Name Dining/Kitchen Floor Area 775 Indoor Dry Bulb Temperature 70°F Time of Peak Jan 12 am Outdoor Dry Bulb Temperature 26°F Conduction surface Area X x X X X x X X X X X x x x X X X X X X X X X X X X X X X X X X X X X X X X X x U -Value X X x x X X X X X x X x x X X x X X X X X X X X X X X X X X X X X X X X X X X x OT °F = = = = = = = = = = = = = _1426 = = = = = = = = = _ _ = Btu/hr R-38 Roof (R.38.2x14.16) 775.0 0.0260 44 887 Slab -On -Grade perimeter = 105.0 0.7300 44 3,373 R2_UN_aILpN_.2L2X616) 569.0 0.0690 44 1,727 Sierra Pacific Fxd Wdw 27 3.0 0.3500 44 46 Sierra_PacifiC-Exd-WAw-(26.) 3.0 0.3500 44 46 Sierra Pacific Fxd Wdw (10) 20.0 0.3500 44 308 Sierra Pacific Fxd We ww (l 1) 20.0 0.3500 44 308 R-21 Wall W.21.2x6.16 40.0 0.0690 44 121 R-29 \Nall (VV 21 2x6 1 150.5 0,0690 44 457 Sierra Pacific Fxd Wdw (16) 20.0 0.3500 44 308 .Sien:alacific-Fxd Wr1w 1 20.0 0.3500 44 Sierra Pacific Csmnt 20 6.0 0.3800 44 100 Sierra Pacific Sldn Dr 076 60.0 0.3600 44 950 �R-21 Wall W.21.2x6.16 192.5 0.0690 584 S.ierr_ a Pacific Sldno Dr (07A 0.3600 I I Items shown with an asterisk (') denote conduction through an interior Infiltration: L 1.00 x 1.064 x Schedule Air Sensible Fraction to another room. 775 x 12.00 Area Ceiling Height 40 91 160 ACH Page Total: a4 DT 10,9501 3. 6 TOTAL HOURLY HEAT LOSS FOR ROOM 14,516 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 25 of 34 ROOM HEATING PEAK LOADS Project Title Date Hideaway / Lot #197 7/20/2007 Room Information Design Conditions Room Name Office/Laundry Time of Peak Jan 12 am ((Floor Area 532 Outdoor Dry Bulb Temperature 26°F indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btulhr (Sierra Pacific Frnch Dr (9) 1 532.0 x 0.0260 x 44 = 609 perimeter = 70.0 X 0.7300 x 44 = 2,248 168.0 x 0.0690 x 44 = 510 48.0 x 0.3900 x 44 = 824 24.0 X 0.3900 X 44 = 412 196.0 X 0.0690 x 44 = 595 24.0 X 0.6000 X 44 = 634 172.0 X 0.0690 X 44 = 522 200 X 00 x 44 = 308 48.0 X 0.3900 x 44 = 824 x x = X x X X x X X X X x = X x = X X = X x = X X X X X X X x x X = X X X X X X X X X X x X x x X X X X X X x X = I x X X X = X x = X x = items snown wnn an asternsK (') denote conduction tnrougn an interior sunace to another room. _ Page Total: 7,4851 Infiltration: 0 x 1.064 x 532 x 10.00 x 0.590 160] x I 4a = 2448 `Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,933 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 26 of 34 I ROOM HEATING PEAK LOADS Project Title Date Hideaway ( Lot #197 7/20/2007 Room Information Design Conditions Room Name Guest Bedrooml Time of Peak Jan 12 am Floor Area 473 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btulhr R-38 Roof R.38.2x14.16 473.0 x 0.02601 x 44 = 541 'R-0 Floor 473.0 X 0.19901 X 0 = 0 I.R_2J_VVa1l_(V_V:212x6 ] 6 190.0 x 0.0690 x 44 = 577 Sierra Pacific Csmnt 28 10.0 x 0.3800 x 441 167 Sierrapacifio_CsnmU29) 10.0. x 0.3800 x 44 44 = 167 Sierra Pacific Csmnt (30 6.0 X 0.3800 x = 100 R-2 Wall W.21.2x6.16 153.0 X 0.0690 X 44 = 465 R-21 Wall W.21.2x6.16 168.0 X 0.0690 X 44 = 510 P� Sierracific-Fsach nr (3 .0 X X 44 = 824 R-21 Wall W.21.2x6.16 36.0 x 0.0690 X 44 = 109 x x = X x X X = x X = x x = x x = x x X x x x = x X = x x x x = x x x X x x x x = i x x x x = x X x X X X x x x x = x x. x X = x x I x x x x = It x x Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total:3,460 Infiltration: F 1.00 x 1.064 x 473 x 9.00 x 0.655 1 601 x ® = I 2 176 —Schedule Air Sensible Area Ceiling Height ACH — ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 5,636 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 27 of 34 ROOM HEATING PEAK LOADS Project Title Date Hideaway / Lot #197 17/20/2007 Room Information Design Conditions Room Name Guest Bedroom 2 Time of Peak Jan 12 am Floor Area 427 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr Wall 427.0 x x X X x X X X X x x x x x x X X X x x x X X X X x x X X X x x X x X x x X x 0.0260 X x x X x x X x x X x x X X x x X x X x x X X X x X X X x x x x X x x x X X X 44 = = = = = = = = = = = = = = = = = = = = = = = 488 427.0 0.1990 0 0 248.0 0.0690 44 753 25.0 0.3800 44 418 6.0 0.3800 44 100 219.0 0.0690 44 665 6.0 0.3800 44 100 114.0. 0.0690 44 346 6.0 0.3800 44 100 6.0 0.3800 44 100 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 3 072 Infiltration: - 1.00 x 1.064 x 427 x 9.00 x 0.655 / 60] x u = 1,964 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 5,036 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 28 of 34 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Hideaway / Lot #197 7/20/2007 Room Information Design Conditions 771 Room Name: Master Bedroom Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,068 sf Outdoor Web Bulb Temperature: 780F iIndoor Dry Bulb Temperature: 780F Outdoor Daily Range: 340F Opaque Surfaces R-38 Roof R.38.2x14.16 R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.16) IR -21 Wall (W.21.2x6.16) I Orientation Area x X X X X x x x x x x x U -Factor X X X X X x x x x x x x CLTD 1 = = = = = = = = - = = = Btu/hr N 1,068.0 0.0180 56.0 1,076 NE 136.0 0.0690 29.0 272 SE 170.0 0.0690 31.0 364 SW 530.0 0.0690 31.0 1,134 NW 176.0 0.0690 30.2 3671 48.0X 27.2= NW 0.0x 21.1+ 24.0X 33.3= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration ICsmnt Wdw (08) 1 Page Total i 3,2131 Orientation Shaded Area x x x x x GLF + + + + + Unshaded Area x x x x x Page GLF = = = = = = SW O.0x 18.7+ 6.0x 25.6= SW 0.0X 19.1+ 64.0X 26.4 SW 0.0x 18.7+ 10.0x 25.6= SW 0.0x 18.7+ 10.0x 25.6= NW 0.0X 18.2+ 48.0X 27.2= NW 0.0x 21.1+ 24.0X 33.3= Total Btu/hr Internal Gain Btu/hr Occu ants4 x Occupants x 230 Btuh/occ. = 920 P P 1Equipment 1 X Dwelling Units X 1,6001 Watts/sgft = 1 600 Infiltration: 1.064 x 1.39 x 75.36 x = 3 797 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 994 Latent Gain jOCCUpants j FI x Occupants X 200 Btuh/oCC. _ Btu/hr 800 Infiltration: 4,771 x 1.39 x 75.36 x 1 0.00263 = 1,3181 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,118 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 29 of 34 I RESIDENTIAL ROOM COOLING LOAD SUMMARY iProject Title Date ;Hideaway / Lot #197 17/20/2007 Room Information Design Conditions Room Name: Great Room Outdoor Dry Bulb Temperature: 1120F Floor Area: 800 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr ' IR -21 Wall (W.21.2x6.16) I IR -21 Wall (W.21.2x6.16) I N 800.0 X X X X x x X X X X X X 0.0180 x X X X x x x X X X X x 56.0 NE 60.0 0.0690 29.0 SE 327.5 0.0690 31.0 NW 160.0 0.0690 30.2 0.0x 21.1+ 6.0x 29.8= 179 SE 0.0 41.4 36.0 57.5 2,070 SE 0.0x 18.7+ 6.0x 25.6= 154 NW 0.0 19.1 176.0 29.4 5,168 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Wdw Door (1 Page Total - 806 - 120 - 701 334 1,961J Orientation Shaded Area X x x x X+ X X Ix GLF + + + + + + +1 Unshaded Area X X x x x-1 X X 1XI GLF = = = = = = = 1= Btu/hr SE 0.0x 18.7+ 12.5x 25.6= 320 SE 0.0x 21.1+ 6.0x 29.8= 179 SE 0.0 41.4 36.0 57.5 2,070 SE 0.0x 18.7+ 6.0x 25.6= 154 NW 0.0 19.1 176.0 29.4 5,168 F Page Total 1 7 891 Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 Equipment :1 x Dwelling Units X 1,600J Wafts/sqft = 1,600 Infiltration: 1.064 x 1.39 x 56.45 x = 2.8441 Air Sensible CFM ELA /�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,216 Latent Gain Btu/hr OccupantsI ®X Occupants x 200 Btuh/occ. = 800 Infiltration: I 4,771 X31 9 x i 56.45 X 0.00263 = 987 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,787 I EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 30 of 34 j RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Hideaway t Lot #197 17/20/2007 Room Information Design Conditions Room Name: Dining/Kitchen Outdoor Dry Bulb Temperature: 1120F Floor Area: 775 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces IR -38 Roof R.38.2x14.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 Orientation Area X X X X X X x X X x X X U -Factor X X X X X x X X X X X X CLTD 1 N 775.0 0.0180 56.0 (NE) 569.0 0.0690 29.0 SE 40.0 0.0690 31.01 (SW) 150.5 0.0690 31.0 NW 192.5 0.0690 30.2 0.0x 21.1+ 20.0X 33.3= SW 0.0X 21.1+ 20.0X 29.8= SW 0.0x 21.1+ 20.0X 29.8= SW 0.0x 18.7+ 6.0X 25.6= SW 60.0X 19.1+ 0.0x 26.4= NW 0.0x 19.1+ 90.0x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw Csmnt Page Total Orientation Shaded Area x X GLF + + Unshaded Area X x Page GLF = NE 0.0x 21.1+ 3.0x 33.3= NE 0.0x 21.1+ 3.0X 33.3= NE 0.0x 21.1+ 20.0X 33.3= NE 0.0x 21.1+ 20.0X 33.3= SW 0.0X 21.1+ 20.0X 29.8= SW 0.0x 21.1+ 20.0X 29.8= SW 0.0x 18.7+ 6.0X 25.6= SW 60.0X 19.1+ 0.0x 26.4= NW 0.0x 19.1+ 90.0x 29. Total Btu/hr 781 1,139 86 322 402 2.7291 Btu/hr Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/occ. = 920 Equipment I x Dwelling Units X 1 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 X 1.39 x 54.68 x 34 = 2 755 Air Sensible CFM ELA IniT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,672 Latent Gain �� Btu/hr ccu Opants 1 4I x Occupants X I 200 Btuh/occ. = 800 Infiltration: j 4,771 x 1.39 x 54.68 x 0.00263 1 956 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11756 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 31 of 34 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Hideaway / Lot #197 17/20/2007 Room Information Design Conditions Room Name: Office/Laundry Outdoor Dry Bulb Temperature: 1120F Floor Area: 532 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 780 Outdoor Daily Range: 340F t Opaque Surfaces IR -21 Wall (W.21.2x6.16) ISolid Wood Door (32) 1 Orientation Area X X X X X x X x X X X X U -Factor X X X X X x X X X X X X CLTD 1 N 532.0 0.0180 77.0 NE 168.0 0.0690 34.0 SE 196.0 0.0690 43.0 SE 24.0 0.6000 47.0 SW 172.0 0.0690 52.0 0.0x 21.7+ 48.0X 57.7= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration ch Page Total Orientation Shaded Area X X X X X x X GLF + + + + + + + Unshaded Area X X X X x X X Page GLF = NE 0.0x 21.7+ 48.0x 32.0= NE 0.0x 21.7+ 24.0X 32.0= SW 0.0x 25.8+ 20.0x 74.7= SW 0.0x 21.7+ 48.0X 57.7= Total Internal Gain Occupants 4 X Occupants X 230 Btuh/oCC. = Equipment 1 X Dwelling Units x 1,200 Wafts/sqft = Btu/hr 7371 394 582 677 617 3.0071 Btu/hr 1,538 769 1,494 2,768 6,569 Btu/hr 920 1.2001 Infiltration: 1.064 x 1.39 x 37.54 x = 1891 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,587 Latent Gain ;Occupants II 41 X Occupants X 200 I Btuh/oCC. _ Btu/hr 800 Infiltration: 4,77 X 1.39 x 37.54 x 000 = 656 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,456 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page: 32 of 34 RESIDENTIAL ROOM COOLING LOAD SUMMARY Title Date lRoom Information Design Conditions Room Name: Guest Bedroom1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 473 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces R-38 Roof R.38.204.16 *R-0 Floor R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 Orientation Area X X X X X X x x x x x x U -Factor X X429.0 XSE XSW XNW X x x x x x x CLTD 1 N 473.0 0.0180 56.0 Btu/hr 473.0 0.1990 18.7 NE 190.0 0.0690 NE 0.0 153.0 0.0690 28.4 284 168.0 0.0690 18.7+ 6.0X 36.0 0.0690 SW 0.0x 18.2+ 48.0X 24.6= 1,182 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Csmnt Nage I otal Btu/hr _ 477 0 380 327 359 75 1,6191 Orientation Shaded Area X x x x x x x X x GLF + + + + + + + + + Unshaded Area x x x X x X x X X GLF = = = = = = = = = Btu/hr NE 0.0 18.7 10.0 28.4 284 NE 0.0 18.7 10.0 28.4 284 NE 0.0x 18.7+ 6.0X 28.4= 170 SW 0.0x 18.2+ 48.0X 24.6= 1,182 I Page Total 1 s2o Internal Gain Btu/hr !occupants 4 x Occupants x 230 Btuh/occ. = 920 Lqui ment :1 X Dwelling Units x 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 x 1.39 x 33.38 x;782 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7 741 Latent Gain Btu/hr Occupants I0 x Occupants X 200 Btuh/occ. = 800) Infiltration: 4,771 x 1.39 x 33.38 x 0.00263 = 584 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,384 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page: 33 of 34 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Hideaway / Lot #197 7/20/2007 Room Information Design Conditions Room Name: Guest Bedroom 2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 427 sf Outdoor Web Bulb Temperature: 78oF Indoor Dry Bulb Temperature: 780F Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr 'R-0 Floor IR -21 Wall (W.21.2x6.16) I N 427.0 X X X X X x X X X X x X 0.0180 x X X X X x X X x x x X 56.0 = = = = = = = = X X X X X X X 427.0 0.1990 0.0 NE 248.0 0.0690 29.0 SW 219.0 0.0690 31.0 NW 114.0 0.0690 30.2 SW 0.0x 18.7+ 6.0X 25.6= 154 NW 0.0x 18.7+ 6.0X 28.4= 170 NW 0.0X 18.7+ 6.0X 28.4= 170 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Wdw rage I otai 430 0 496 468 238 1,6331 Orientation Shaded Area X X X X X X x GLF + + + + + + + Unshaded Area X X X X X X X GLF = = = = I = Btu/hr NE 0.0x 18.7+ 25.0x 28.4 710 NE 0.0 18.7 6.0 28.4 170 SW 0.0x 18.7+ 6.0X 25.6= 154 NW 0.0x 18.7+ 6.0X 28.4= 170 NW 0.0X 18.7+ 6.0X 28.4= 170 Page Total 1 374 Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 E ui ment 11 X Dwelling Units X 1,6001 Wafts/sgft = 1,6001 Infiltration: 1.064 x 1.39 x 30.13 x = 1518 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,0451 Latent Gain _ Btu/hr Occupants 0 x Occupants X 200 Btuh/occ. = 800 Infiltration: j 4,771 x 1.39 x 30.13 x 0.00263 = 527 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,327 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:34 of 34 r TITLE 24 REPORT Title 24. Report for:. Hideaway / Lot #197 (Guest Casita) 197 Via Chiante La-Quinta, CA 92253 Project Designer Studio Linea 57-770 Black Diamond La Quinta ,. CA 92253 (760) 899-3368 Report Prepared By: C.J. McFadden C.M. Energy',Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260. (760) 346-8014 Job Number Date: f 7/20/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 1086 EnergyPro 4.3 by EnergySoft Job Number: User Number: 1086 Certificate Of Comaliance : Residential (Part 1 of 4) CF -1 R _H.i.de.awa_y_/_Lot_#_1.9.7_(G_uestCasita)7/20/20-07 Project Title 1.97 V_ia Chiaate-La_Quinta 775 ft2 Existing Floor Area: Date Project Address Raised Floor Area: 0 Building Permit # oc�um EaeongyuCOnsuffi g 775 (760hor p o46-8014 ne Average Ceiling Height: Plan Check/Date _Ene.1� rPM Compli ce Method Number of Dwelling Units: CAC1in3ateZoaeL15 Climate Zone Kew- _09JA6 Field Check/Date 1 TDV Standard Proposed Compliance ❑ (kBtu/sf-yr Design Design Margin Space Heating 2.17 4.79 -2.62 Space Cooling 80.55 73.04 7.51 Fans 11.51 10.28 1.23 Domestic Hot Water 21.89 21.85 0.04 Pumps 0.00 0.00 0.00 ❑ Totals 116.12 109.95 6.17 Percent better than Standard: 5.3% Building Type: [X-] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: Area: 148 ft2 Ratio: 19.0% BUILDING ZONE INFORMATION ❑ Addition ❑ Existing + Add/Alt (NW) 315 deg Natural Gas Avg. U: 0.38 Avg. SHGC: 0.29 Total Conditioned Floor Area: 775 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 775 ft2 Average Ceiling Height: 11.0 ft Number of Dwelling Units: 1.00 Kew- _09JA6 Number of Stories: 1 # of Zone Name Floor Area Volume Units Zone Type .HVAC -#-1 775 -8,525 1_.0.0_ Living OPAQUE SURFACES Insulation Act. Gains Condition Thermostat Vent Type Hgt. Area I ivingS.tat- 2 -n/.a Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments .Roof Wall_ Wall_ Wall- Wall_ Wood_ Wood_3.0.4_ Wood_ Wood_ Wood_ 7_Z5_ _0-026_ -R38_ X0.0_ 0_ 0 0-069 -R21_ X0._0 ___A5__90 307. _0_069 R -21_L1_'0._0 X35 _9.0 304_ _0_0.69 -R_21. __R_-0_0 -225_ 9.0 _29.8_ _0_0.6.9_ R-21 0...0 _315__90. New N.ew 01=A8 09=A6 -0.9=A6 0.9- Zone 1 Zone -1 Zone 1 Zone 1 IX [X [X IX IX F-1 ❑ ❑ ❑lqew ❑flew El ❑ Kew- _09JA6 one 1❑ Zone-1-- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ n ❑❑ ❑❑ El L1 Run Initiation Time: 07/18/07 17:20:22 Run Code: 1184797222 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Pam:3 of 12 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R_ Hideaway / Lot #197 (Guest Casita) Project Title Date 7/20/2007 FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments _L Wiadow_Rear (SE) —3.60_ _0.3.8.ONEBC_ 0._3.0 -NERC _13.5_ _90-N.ew—Sierra-EacificCmat �/_dw._(.01)--Zone 1 2 Window Rear (SE) 12.5 0.380 NFRC 0_30 NFRC 135 90 New Sierra Pacific Cmnt Wdw (03) Zone 1 3 Window Rear (SE) 12.5 0.380 NFRC 0_30 NFRC 135 90 New Sierra Pacific Cmnt Wdw (04) Zone 1 4 Window Right (SW) 12.5 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Cmnt Wdw (02)_ Zone 1 5 Window Right (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Cmnt Wdw (05) Zone 1 6 Window Right (SW) 10.0 0.380 NFRC 0_30 NFRC 225 90 New Sierra Pacific Cmnt Wdw (06)_ Zone 1 7 Window Front (NW) 48.0 0.390 NFRC 0_28 NFRC 315 -92 New Sierra Pacific Frnch Dr (1$) Zone 1 8 Window Front (NW) 6.0 0.380 NFRC 0.30 NFRC 315 90 New Sierra Pacific Cmnt Wdw (18) Zone 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 T Bu Screen 0.76 8 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Run Initiation Time: 07/18/07 17:20:22 Run Code: 1184797222 EnergyPro 4.3 by EnergySoft User Number: 11086 Job Number: Page:4 of 12 Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 90 None No Insulation 26-A1 New Zone 1 Run Initiation Time: 07/18/07 17:20:22 Run Code: 1184797222 EnergyPro 4.3 by EnergySoft User Number: 11086 Job Number: Page:4 of 12 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R t Hideaway / Lot #197 (Guest Casita) 7/20/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling ' Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback ZEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: . C.J. McFadden Title/Firm: Studio Linea Title/Firm: C.M. Energy Consulting Address: 57-770 Black Diamond -Address: 72-925 Fred Waring Drive, Suite 204 La Quinta , CA 92253 Palm Desert, CA 92260 Telephone: (77 899-3368 Lic. #: Telephone: -760 346-8014 Z2 el -p- VI -110 07 (si atu ) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) I EnergyPro 4.3 by Ener Soft User Number: 1086 Job Number: Page:5 of 122 r l . HVAC DISTRIBUTION + Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #1 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. t Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal. Small Gas No Pipedrisulation 1 40,000 50 New 0.58 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insulation ZEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: . C.J. McFadden Title/Firm: Studio Linea Title/Firm: C.M. Energy Consulting Address: 57-770 Black Diamond -Address: 72-925 Fred Waring Drive, Suite 204 La Quinta , CA 92253 Palm Desert, CA 92260 Telephone: (77 899-3368 Lic. #: Telephone: -760 346-8014 Z2 el -p- VI -110 07 (si atu ) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) I EnergyPro 4.3 by Ener Soft User Number: 1086 Job Number: Page:5 of 122 r l . Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Hideaway/ Lot #197 (Guest Casita) 7/20/2007 Project Title f' Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The HVAC System "HVAC #1" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. c f Run Initiation Time: 07/18/07 17:20:22 Run Code: 1184797222 " EnergyPro 4.3 by Energysoft User Number: 1086 Job Number: Page:6 of 12 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). ❑ ❑ ❑ f§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑ ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:7 of 12 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain'a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section P19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:8 of 12 r 1) .r 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hideaway / Lot #197 (Guest Casita) 7/20/2007 SYSTEM NAME FLOOR AREA HVAC #1 775 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 43,000 Total Output (Btuh) 43,000 Output (Btuh/sqft) 55.5 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 45.2 Total Output (sgft/Ton) 265.7 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.55 Airflow (cfmrron) 411.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above 26.0 of I Outs 0 cfm 68.7 of 11.0 / 77.6 of }--I Outside Air 0 cfm 79.5/63.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 49 12,011 1,598. 347 12,924 0 1,867 1,658 0 0 0 0 0 0 0 0 0 1,867 1,658 15,745 1,598 16,240 PSA26D / PGC1RA (3 Ton) 13 SEER 30,336 0 43,000 Total Adjusted System Output 30,336 0 43,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am at ARI conditions I L- YCHROMETRICS (Airstream Ter 68.7 OF ® 105.OoF EM PSYCHROMETRICS Heating Coil 79.5 / 63.1OF at Time of Heating Peak) 105.0 of Supply Air Ducts Supply Fan 103.7 of 1200 cfm ROOMS 70.0 of �% Return Air Ducts 4 55.0 / 53.7 of u ori Cooling Coil Supply Fa 1200 cfm 55.0 / 53.7 of Is Supply Air Ducts Fan 56.5/54.3OF 42.4% R.H. ROOMS 78.0 / 62.6 of n:_ r%.._._ L_ EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:9 of 12 1 4, Cr ROOM LOAD SUMMARY PROJECT NAME Hideaway / Lot #197 (Guest Casita) DATE 7/20/2007 SYSTEM NAME HVAC #1 FLOOR AREA 775 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Lot 197 Guest Casita 1 491 12,011 1,598 491 12,011 1,598 347 12,924 PAGE TOTAL 1 491 12,011 1,598 347 12,924 TOTAL 1 491 12,011 1,598 347 12,924 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 12 ,%l -) Q. 6 ROOM HEATING PEAK LOADS Project Title Date Hideaway / Lot #197 (Guest Casita) 7/20/2007 Room Information Desian Conditions Room Name Lot 197 Guest Time of Peak Jan 12 am Floor Area CIA Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1.2x6.1 775.0 x x x x x x X x x x X x x x x x X x X X X X X x X X X X x X X X X X X X X X X 0.0260 x x x x x x x X x x x x x x x x x X X x x x x X x X X x X X X x X X x x X X X 44 = = = = = = = = = = = = = = = = = = = = = = = - = 887 perimeter = 90.0 0.7300 44 2,891 304.5 0.0690 44 924 307.0 0.0690 44 932 36.0 0.3800 44 602 12.5 0.3800 44 209 12.5 0.3800 44 209 303.5 0.0690 44 921 12.5 0,3800 44 209 10.0 0.3800 44 167 10.0 0.3800 1-6-7- 67298.0 298.0 0.0690 44 905 48.0 0.3900 44 824 6.0 0.3800 44 100 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,947 Infiltration: [ 1.00 x 1.064 x 775 x 11.00 x 0.447 / 60] x 44 = 2 976 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,924 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 11 of 12 1-4c .. ,1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Hideaway / Lot #197 (Guest Casita) 7/20/2007 Room Information Desicin Conditions Room Name: Lot 197 Guest Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 775 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F opaque ourtaces R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) .21.2x6.1 Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X X CLTD 1 = = = = = = = = = = Btu/hr (N 775.0 0.0180 56.0 781 NE 304.5 0.0690 29.0 609 (SE) 307.0 0.0690 31.0 657 SW 303.5 0.0690 31.0 649 NW 298.0 0.0690 30.2 622 10.0X 25.6= (SW 0.0x 18.7+ 10.0x 25.6= (NW) 0.0 18.2 48.0 27.2 NW 0.0x 18.7+ 6.0X 28.4= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration French Page Total 1 3,3181 Orientation Shaded Area X x x X x GLF + + + + + Unshaded Area X X x X x Page GLF = = = = = SE O.OX 18.7+ 36.0X 25.6= SE 0.0x 18.7+ 12.5X 25.6= SE 0.0x 18.7+ 12.5X 25.6= SW 0.0 18.7 12.5 25.6 SW 0.0X 18.7+ 10.0X 25.6= (SW 0.0x 18.7+ 10.0x 25.6= (NW) 0.0 18.2 48.0 27.2 NW 0.0x 18.7+ 6.0X 28.4= Total Btu/hr Internal Gain Btu/hr Occupants 4 x Occupants X 230 Btuh/occ. = 920 Equipment 1 x Dwelling Units X 1,6001 Wafts/sqft 1 1,6001 Infiltration: 1.064 x 1.16 x 54.68 x 34 = 2 300 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,0111 Latent Gain Btu/hr Occupants 4� x Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.16 x 54.68 x 0.00263 = 798 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,598 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 12 of 12