Loading...
BMCH2016-0345' I VOICE (760) 777-7125 78-495 CALLS TAMPICO D FAX FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT (760) 777-7153 BUILDING PERMIT Date:1?9-- 0016 Application Number: BMCH2O16-0345 Owner: Property Address: 49448 VIA CONQUISTADOR KATHLEEN 5WEETMAN c ;. APN: 602260026 105 W SPY GLASS DR ci < J, —U !� Application Description: SWEETMAN / HVAC CHANGE OUT (1) SPLIT SYSTEM SIOUX FALLS, SD 92253 Property Zoning: Application Valuation: $8,400.00 N Applicant: Contractor: PALM DESERT AIR CONDITIONING CO INC DBA PALM DESERT AIR CONDITIONING C0;-1'NC�DBA '- 42-081 BEACON HILL 42-081 BEACON HILL PALM DESERT, CA 92211 PALM DESERT, CA 92211 (760)346-0677 Llc. No.: 374937 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Clas : C20 License No.: 374937 r Date: v'o Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permitto file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code).or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). , {_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY ' I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: \ Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5029447 i I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I s II forthwith comply with thos provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE I NLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made,'each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-m!nyoneq property for inspection purposes. Date: Signature (Applicant or Agent): Date: 9/13/2016 Application Number: BMCHM16-0345 Owner: Property Address: 49448 VIA CONQUISTADOR KATHLEEN SWEETMAN APN: 602260026 105 W SPY GLASS DR Application Description: SWEETMAN / HVAC CHANGE OUT'(1) SPLIT SYSTEM SIOUX FALLS, SD 92253 Property Zoning: Application Valuation: $8,400.00 Applicant: Contractor: PALM DESERT AIR CONDITIONING CO INC DBA PALM DESERT AIR CONDITIONING CO INC DBA 42-081 BEACON HILL 42-081 BEACON HILL PALM DESERT, CA 92211 PALM DESERT, CA 92211 (760)346-0677, --------------------------------------------------------------------------------------------- Llc. No.: 374937 Detail: HVAC CHANGE OUT - 16SEER/8AFUE SPLIT SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. I FINANCIAL INFORMATION, DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $72.52 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $36.26 Total Paid for CHANGEOUT: $108.78 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $91.85 I 1 I sin .# Qty Of La QuInta Building a Safety Division P.O. Box 1504,•78-49S Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit -Application and Tracking Sheet Permit # Project Address: 49-448 VIA CONQUISTADOR Owner's Name:. SWEETMAN, KATHLEEN A. P. Number. Address: 49-448 VIA CONQUISTADOR Legal Description: RESIDENTIAL Contractor. PALM DESERT A/C CO. INC. City, ST, Zip: 92253 Telephone: 605-321-4574 3s Address: 42-081 BEACON HILL Project Description: Change out of (1) (3) ton split horizontal City, ST, Zip: PALM DESERT CA. 92211 heating and cooling system..(16) SEER; (13) ERR Telephone: 760-346-0677 : %` • ^Y MEN ''f s:; Q mil programmable and. WI FI thermostat , State Lic. # : 374937 City Lie'. #, LIC -0100886 ac brand is American Standard Arch., Engr., Designer Address: $8,40.0.00 City., ST, Zip: Telephone: '`��� ;':: '' '" s' Construction Type:. Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.:#Stories: #Univ: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Reed TRACKING PERMITFEES- Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. . Called Contact Person Plan Check Balance. Title 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan tad Review, ready for correctionsPissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SALL H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^! Review', ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 1 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3 ) Project Name: SWEETMAN, KATHLEEN Date Prepared: 2016-09-13 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single.dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 01 Project Name SWEETMAN, KATHLEEN 02 Date Prepared 2016-09-13 03 Project. Location 49-448 VIA CONQUESTADOR 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name SWEETMAN, KATHLEEN 07 Zip Code 92253 08 Dwelling Unit Conditioned 3348 Floor Area (ft2) SC System SC System r "CFA served�'*-4!s�ystem a refrige At -1 nstallirig new SC (. Installing %I stalling Installing `>> Identification or Number of space conditioning by this SC 09 Climate Zone 15 10 (SC) systems in this dwelling 1 Name Served System (ft2) unit. component? s — t ` B. Space Conditioning (SC) System Information..,.Wft 01 02. 03 ' 04.05 09 10 -,$ . G -.,Cls the SC Installing a SC System SC System r "CFA served�'*-4!s�ystem a refrige At -1 nstallirig new SC (. Installing %I stalling Installing Identification or Location or Area by this SC ducted containing system more than 40' e t ely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 BEDROOMS 1200 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 216-A0337591A-000000000-0000 Registration Date/Time: 2016-09-13 12:05:48 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated:. 2016-09-13 12:05:31 CERTIFICATE OF COMPLIANCE CF111-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04_ 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value System 1 tral Cfurnace enis All new heating AFUE 8 Centrals IT-Allne pcooling w - SEER 16 Setback Less than or equal to 40 R-8 components AC components feet Required Documentation: ' CF2R-MCH-03-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing -required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced.. -Leakage rate compliance: <_ 15%, or15 10% leakage to outside,"or seal all accessible leaks. C17211 -MCH -25-1-1 & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 AirFlow:2 300.CFM/ton regwred when -..MCH -25 is required. ' Exceptions:-` -' -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements let. Charge MECH 25 -Heating-only systems and Air Handler/Furnace changes do not require venficaUon of Air Flow MCH''23 or Refrigerant MCH`=20Duele�akage Testinggrequiunts ` -Existing duct systems constructed, insulated or sealed with asbestos;are exemptfrom eme Y4. - .:#. 'Pi. U M1, :*If 5k%s " 'M, -lrr� '7C 1wAi Ytt "P�t. t��iss;' � E. Entirely New or Complete Replacement Duct�Sys=tem, with or withou:t�Equipment Changeout (S.ectlons„150.2(b)lDiia;and 150.2(b)1E, F) 4 ' .� ' This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)IC) This section does not apply to this project. Registration Number: 216-A0337591A-000000000-0000 CA Building Energv Efficiencv Standards - 2013 Residential Compliance Registration Date/Time: 2016-09-13 12:05:48 HERS Provider: CalCERTS Report Version: 2013 Rev 1.008 Report Generated: 2016=09=13 12:05:31 CERTIFICATE OF. COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: McCoy, William O Company: Signature Date: Palm Desert Air Conditioning Co 2016-09-13 12:05:48 Address: CEA/ HERS Certification Identification (if applicable): 42-081 Beacon Hill ' City/State/Zip: Phone: Palm Desert CA 92211 760-346-0677 Responsible Person's Declaration statement:; I certify the following under penalty of perjury, under the aws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of -the Business"and Professions Code to.accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications materials components, and manufactured devices for the building .design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part land Part 6 of the California Code of Reg la ions.' t z 't k4,, ars.i� 4. The building design features or system design features identified on.�this Certificate of Compliance are1'consiStent with the informat(onwprovided on'.othe�rappltcalile compliance documents, worksheets, ae a u i .i •, fix; r#sl �. building calculations, plans and specifications sutimittedrto the eriforcemenl4gency fo approvallwith this permit application. shall wrth;the )tissued tathe enforcement agency for all applicable S.. I will ensure that a registered copy of this Certificateabf C mpliance be3made available 4i ilding permit( fortthecf�mldi�ng, and�made available :,.t •° . inspections. I understand that a registered copy of thls,Cert� irate of Compl ance is required to be included www ths.Qcum�enj�ation the builder provides toahe build owner at occupancy. Z) Responsible Designer Name: �«.r a��. 's� a Pa Responsible Designer Signature:%7�/G�GGG�fl/Gi/df �/ McCoy, William v Company: Date Signed: Palm Desert Air Conditioning Co - 2016-09-13 12:05:48 Address: License: 42-081 Beacon Hill 374937 City/State/Zip: - Phone: Palm Desert CA 92211 760-346-0677 - Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0337591A-000000000-0000 Registration Date/Time: 2016-09-13 12:05:48 HERS Provider: CaICERTS 09 13 12:05:31 rA Q,,i1A; c .o.R cs� o���� cranrinrric - 2n1'3 Raciripntial Comoliance Report Version: 2013 Rev 1.008 Report Generated: 2016 .