Loading...
BRES2017-014378-49S CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2017-0143 .Property Address: 44325 VIA CORONADO APN: 604211016 Application Description: MARTIN RESIDENCE/ Property Zoning: Application Valuation: $0.00 Applicant: RUDOLPO LIZARDE 42740 BROWNSTONE BERMUDA DUNES, CA 92203 414Q4bqL DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT TION &.REM_ 0`DEL ) L AUG 0 82 0 1 Jyt07nOF 4OUNTA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. . License Class: B License No.: 724728 IIIIIIIIIn'. Contractor: OWNER -BUILDER DECLARATION I hereby.affirm under penalty of perjury that l am exempt from the Contractor's State License Law for the following reason (Sec. 7031:5, Business and.Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant.for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031:5 by any applicant for a permit subjects the applicant to a civil -penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or.offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden.of proving that he or she did not build or improve for the purpose of sale.). . (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760)777-7153 Date: • 8/8/2017 Owner: % DAN MARTIN 44325 VIA CORONADO LA QUINTA, CA 92253 Contractor: COSTANTINIDIS AND DAUGHTERS CONST 1841 AMIE CT SAN MARCOS, CA 92069 (760)668-2033 Llc. No.: 724728 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations:. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this.permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in'any manner so as to become subject to the workers' ' compensation laws of California, and agree that, if 1. should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith complyith those provisions. Date: 4 kr 707mw—Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE'HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. '2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the aboveentioned property for inspection purposes. Date: 8/8/2017. Application Number: BRES2017-0143. Owner: . Property Address: 44325 VIA CORONADO DAN MARTIN APN:. 604211016 ' 44325 VIA CORONADO Application Description: MARTIN RESIDENCE / ADDITION & REMODEL LA QUINTA, CA 92253 . Property Zoning: Application Valuation:, $0.00 Applicant: Contractor: RUDOLPO LIZARDS COSTANTINIDIS AND DAUGHTERS CONST '42740 BROWNSTONE 1841 AMIE CT BERMUDA DUNES, CA 92203 SAN MARCOS, CA 92069 . (760)668-2033 Llc. No.: 724728 Detail: ADDITION + REMODEL. ENCLOSE EXISTING -1 -CAR GARAGE TO BEDROOM (ADDITION OF 220 ADDITIONAL SF OF CONDITIONED SPACE). DIVIDE EXISTING DINING AND LIVING ROOM SPACES TO (2) ADDITIONAL BEDROOMS;. RELOCATE EXISTING WATER HEATER TO NEW ENCLOSURE ATAEAR OF NEWLY ENCLOSED BEDROOM.(CONVENTIONAL LIGHT -FRAME CONSTRUCTION). 2016 CALIFORNIA BUILDING CODES. -..DFSCRIP.TION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $65.36 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, £A ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT CITY AMOUNT ' ADDITION, FIRST 100 SF' 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600. 0 $179.36 Total Paid for ADDITION: $390.64 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $76.00: Total Paid for BLDG CITY STAFF -PER HOUR: $76.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $70.84 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $17.64 Total Paid for ELECTRICAL: $139.14 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $5.07 Total Paid for MECHANICAL: $93.74 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT . WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 a - ! DESCRIPTION ACCOUNT QTY AMOUNT - ,—WATER. -SYSTEM 1NST/A4T/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $121.63' DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $45.60 DESCRIPTION -ACCOUNT QTY AMOUNT REMODEL,.EA ADDITIONAL 500 SF PC 101-0000-42600 0 $36.48 DESCRIPTION ACCOUNT QTY, AMOUNT REMODEL, FIRST 100 SF 101-0000-42400. 0. $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $275.12 DESCRIPTION' ACCOUNT QTY 'AMOUNT SMI - RESIDENTIAL. 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE S02-0000-43611 36 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: t Bin# j 2 I O\ City of La Quinta Building & Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit# Project Address: 2 �� �1 6 �� Owner's Name W �-rf/v U� A.P. Number �71L-� c7 �1 ff -7 Address: J/1,1 Gd /"•�00 Legal Description: City, ST, Zip: (Wot , d �1 CA �`LL S,3 Contractor: C'n s TA-rNl a 13 �(�t,�ex-I Tele phone: , Address:gr,/ M/ r G Project D s i ti n' e e?'-__e4_0 VA r City, ST, Zip. MtAtj CA 20 fp s Teleph V) f _ '1# _r*'iJ WtYL ACif T State Lic. #: 762 q'7n• City Lic #: Arch, Engr., Designer: Address: City, ST, Zip: 'telephone: State Lic. #: Construction Type�6Z1,f,,,. Occupancy: Proj. Type New Add'n Alter Repair Demo Name of Contact: SgFt: #Stories # Units: Telephone of Contact: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check Submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan Check Balance: Title 24 Cales Plans Picked Up Construction: Flood Plain Plan Plans Resubmitted Mechanical: Grading Plan 2nd Rev, Ready for corrections / Electrical: Subcontractor List Called Contact Person Plumbing: Grant Deed Plans Picked Up S.M.I. HOA Approval Plans Resubmitted Grading IN-HOUSE 3rd Rev, Ready for corrections / Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Apps Date of permit issue School Fees Total Permit Fees D UJ -71 � /I -� B,rr # City of La Quints Building a Safely Division O(.q; P.O. Box 1504,78-495 Calle Tampfco La.QWnta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # ,��o Project Address: 41, Owner's Name:. Dtin i A� A P. Number. Address: 1i2 ` lN co izory- Legal Description: City, ST, Zip: Contractor. Telephone: -M- ate° Address: Project Description: City, ST, Zip:�''FA . 11Li v p�r •�0••+ Telephone: o 1 NVE State Lic. # : City Lie'. #, Arch., Engr: esigner 960C} t Fv L( )- Address: LZ40 LV&1& /%.t �/✓ 1� City., ST, Zip: VU N e (IN Telephone: Construction Type:. - Occupancy: rz- 3. • 7 State Lic. #: f 3;� Project type (circle one): NewAdd' Alter Repair Demo Name of Contact Person: OIDOLF6 u I AW Sq, Ft: 2-Zd # Stories: # Unita: Telephone # of Contact Person:`Z(EQr1B1S —2 -d -L -7 Estimated Value of Project 6 0 0 0- - -APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKMG PERMIT FEES Plan Sets Pian Cheek submitted Item Amount Structural Calm Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person Plan Check Balance 'L' Title U Calci. Plans picked up Construction Flood plain plan Pians resubmitted Mechaelcal Grading plan 2'! Review, ready for correctionsPcssue Electrical Subcontactor Ust Called Contact Person plumbing Grant Deed Plans picked up S3LL ILOA Approval Plans resubmitted Grading IPI HOUSE:- '"` Review; ready for correctionvIssae Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees Date: 7/20/2017 No.: 17-00665-1 Owner: Dan Martin Address: 44325 Via Coronado City: La Quinta Type: Residential Addition < 500 sq ft CERTIFICATE OF COMPLIANCE N�f+eo scy� Desert Sands Unified School District �Qy9 47950 Dune Palms Road , MI (36 a La Quinta, CA 92253 M INOIAN wEUS h a� C A uM, L�"--'nn�y (760)771-8515 9 IN Y` Email: Jurisdiction: La Quinta Tract #: Lot # Street No. Street Name Sq. Feet 44325 Via Coronado 220 Comments: APN Permit No. 604-211-016 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 220 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt - Rodolfo Lizarde Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Check No.: Telephone: Funding: Exempt Certifizatie Fees Due.,-, $O.w Original Paymeht(s) New PaVsrient;Rec'd.- $0.00 �i• `�- v97 1/ v j VF cow- ,- — •fiver/Under: t 100 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to not/ed u that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the bor installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authoro collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. Plan Submittal Job Site Ownefs N Number, Sheet, or PO City, Sime, Posml C Ownefs Phone Nun Ownefs E -Mail Add Project Managafa Project Menagefs Phone N Builder / ConIn Number, Sheet or PO City, State, Postel C Project square _ T Project Descriptlon: smaA addition w/garage Exempt D (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan City Approval By Date of City Approval To Be Discards Product Trash Asphalt BriddSlock Cardboard Commingled Concrete Drywall Donated / Reuse* 712=017 44325 Villa Coronado Dan Martin 44325 Villa Coronado La Quinta, CA. 92253 Daniel Mora "2-275=5253 Daniel Mora P.O. Box 2377 Valley Center, CA. 92082 Approx. 600 square feet Renado Qouldhxk-DEC/Runtec Waste . 01 17 ble Product Tons Masonry (broken) O.0 Plaster 0.7 Scrap Metal O.0 Tile (floor) 01 Tnie (roof) 01 Wood 1 1.2 Landscape Debris _O.0 I*Describe items I Totals: Rec cls Trash Projected Diversion: 2.5 1.3 86.51% i understand It is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmentai Coordlnatw as these hauls occur. I hereby certify that completion, implementatlon and adherence of the Debris Management Pian (DMP) for the above named project shall guarantee that at least tab% of the jobsite waste is diverted from landtiIDng. The remaining material will be recycled or reused. I WRI divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued M the name of the property owners) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued n the name of the property nd the owner retains legal responsibigty for ensuring that the provisions of the DMP red to. The pro er(s) nd general contractor shall be kept informed of the dhverston. progress through bkmna IVY ons. If -h ng, aterial from this project site must be taken to an appro mvjclw or transfer 7Z7 Zn/7 Ownbr / Developer / Pro ct Manager / Superintendent Date I Construction Debris Management Plan Summary of Requirements As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction of most new structures in the state of California comply with sections 4.408 and 5.408 of the code in accordance with Assembly Bill 939 requiring that no more than 36% of jobstte waste be disposed of as trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under —__._—_c ertaln conditns: - _- The City of La Quints is committed to the highest level of environmental respect, to conserving our precious natural resources and setting an example to provide for a better world for generations to come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs. IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise hauler. If you choose to self -haul any recyclables or trash, you must provide copies of all weight tickets and/or receipts from the transfer station, landfill, or recycler as the job progresses. Clean-up companies and other haulers are not permitted to haul waste or recyclables from the City of La Quinta. Self -haul weight tickets should be submitted to: Renado Gouidlock, District Environmental Coordinator - rgouldiock@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to: 41575 Eclectic Street, Palm Desert, CA. 92260. STATE,.QF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 1 of 9) Project Name: Martin enclosure Date Prepared: 6/22/2017 This compliance document is only applicable to additions 300 ft" or less, or additions that do not require HERS field verification for compliance. When HERS verification is required, a CF1R-ADD-01 shall first be registered with a HERS Provider Data Registry. Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CF1R-ADD-02 and CF2R- ADD -02 Compliance Documents. Possible exemptions from duct leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CFIR-ADD-01 must be completed and registered with a HERS Provider Data Registry. Additions or alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R -value other than 5.8 per inch, or Open Cell Spray Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R -value of 3.6 per inch, shall complete and register a CFIR ADD -01 with a HERS Provider Data Registry. If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures,,shall be met. Temporary labels shall not be removed before verification by the building inspector. A. General Information 01 Project Name: Martin Enclosure 02 Date Prepared: 6/22/2017 03 Project Location: 44325 Via Coronado 04 Building Front Orientation (deg): 90 05 CA City: La Quinta 06 Number of Dwelling Units with Additions: 1 07 Zip code: 92253 08 Fuel Type - Natural Gas 09 Climate Zone: 15 10 Total Conditioned Floor Area (ft) (Addition): 220 11 Building Type: Single Family 12 Slab Area (ft): 220 13 Project Scope: Garage enclosure adding 220 sq. ft. to Living Space BQe6Zol7-0fq:3> CITY OF LA QUINTA BUILDING & S®�E�®PT• APPIR FOR CONSTRUCTION DATE? (P,713y = CA Building Energy Efficiency Standards - 2016 Residential Compliance April STATE QF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CF1 R -ADD -02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 2 of 9) Project Name: Martin Enclosure I Date Prepared: 6/22/2017 B. Opaque Surface Details — Framed (Section 150.2(a)) 01 02 03 04 05 06 07 08 09 10 11 Tag/ID Assembly Type Frame Type Frame Depth (inches) Frame Spacing (inches) Proposed Required Comments Cavity R -value Continuous Insulation R -value U -Factor Appendix JA4 Reference U -Factor Table Cell ROOF ROOF WOOD VARIES 24" O.C. R-38 N/A 0.32 150.1-A 15 0.32 E -WALL EXTERIOR WALLS WOOD 3.5 16" O.C. R-15 N/A 0.125 150.1-A 15 0.125 N -WALL EXTERIOR WALLS WOOD 3.5 16" O.C. R-15 N/A 0.125 150.1-A 15 0.125 -WALL EXTERIOR WALLS WOOD 3.5 16"O.C. R-15 N/A 0.125 150.1-A 15 0.125 CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 3 of 9) Project Name: Martin Enclosure I Date Prepared: 6/22/2017 C. Opaque Surface Details — Non -framed (Section 150.1(c)1) 01 02 03 04 1 05 06 07 08 09 10 11 Tag/ID I Assembly Type Assembly Materials Thickness (inches) Proposed Required Comments Core Insulation R -value Continuous Insulation R -value U -Factor Appendix JA4 Reference U -Factor from I Package A Table Cell Exterior Insulation R -value U -factor R -value U -factor Table Cell R -value I U -factor R -value U -factor N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A D. Opaque Surface Details - Mass Walls (Section 150.1(c)1) 01 02 03 04 05 06 07 08 1 09 10 11 Tag/ID Walls Above Grade I Mass Type Mass Thickness (inches) Furring Strip Thickness (inches) Proposed Required Interior Insulation Exterior Insulation Appendix JA4 Reference Interior Insulation Exterior Insulation R -value U -factor R -value U -factor Table Cell R -value I U -factor R -value U -factor N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 4 of 9) Project Name: Martin Enclosure I Date Prepared: 6 /2 2 /2017 E. Slab Insulation (Table 150.1-A) 01 02 03 04 05 06 Floor Type Proposed Required Comments Insulation R -value Insulation U -factor Insulation R -value Insulation U -factor Slab -on -grade N/A N/A N/A N/A Note: • Heated slab floors require mandatory slab insulation (see Table 110.8-A). F. Radiant Barrier (Section 150.1(c)2) 01 02 Radiant Barrier installed below the roof deck and on all gable end walls Comments YES A radiant barrier is required (for Climate Zones 2-15) • Radiant barriers shall meet specific eligibility and installation criteria to receive energy credit for compliance with the Building Energy Efficiency Standards for low-rise residential buildings. Refer to RA4.2.1 • The emittance of the radiant barrier shall be less than or equal to 0.05 as tested in accordance with ASTM C1371 or ASTM E408. • For Prescriptive Compliance the attic shall be ventilated to provide a minimum free ventilation area of not less than one square foot of vent area for each 300 ft2 of attic floor area with no less than 30 percent upper vents. Ridge vents or gable end vents are recommended to achieve the best performance. The material should be cut to allow for full airflow to the venting. CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE JDF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CF1 R -ADD -02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 5 of 9) Project Name: Martin Enclosure Date Prepared: 6/22/2017 G. Roofing Products (Cool Roof) (Section 150.1(c)11) 01 02 03 04 05 06 07 08 09 10 11 12 Mass Roof 25lb/ft2 or Greater Roof Pitch Method of Compliance Product Type CRRC Product ID Number Proposed Required Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI (Optional) Aged Solar Reflectance Thermal Emittance SRI (Optional) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A The Greater Addition Allowed Allowed Allowed Allowed Type ftZ U -factor U -factor SHGC SHGC Comments Maximum Maximum Calculated Maximum Calculated Maximum (Windows) (Skylights) (Windows) (Skylights) Calculated Calculated based on Allowed ft based on Allowed ft Allowed % Allowed % 220<400 Notes: • Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. • Liquid field applied coatings must comply with installation criteria from section 110.8(1)4. H. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150.2(a)1) 01 02 1 03 04 1 05 06 07 08 09 10 Maximum Allowed Maximum Allowed Fenestration Area for All West -Facing Fenestration Orientations ft2 Area Only ftZ Maximum Maximum Maximum Maximum The Greater The Greater Addition Allowed Allowed Allowed Allowed Type ftZ U -factor U -factor SHGC SHGC Comments Maximum Maximum Calculated Maximum Calculated Maximum (Windows) (Skylights) (Windows) (Skylights) Calculated Calculated based on Allowed ft based on Allowed ft Allowed % Allowed % 220<400 66 sq. ft. n/a n/a 0.32 n/a 0.35 n/a CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification 3211 CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF111-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 6 of 9) Project Name: Martin Enclosure Date Prepared: 6/22/2017 I. Fenestration Proposed Areas and Efficiencies Note: If meeting Exception 1 to 150.1(c)3A, Installing <_ 3ft2 glass in door, it is assumed to meet the minimum required U -factor (0.32) & SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <_ 3ft2 tubular skylight, it is assumed to meet the minimum required U -factor (0.55) & SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Tag/I D Fenestration Type Frame Type Dynamic Glazing Orientation N, S, W, E or Roof Number of Panes Proposed Fenestration Area ftZ Proposed West Facing Fenestration Area ft Proposed U -factor Source Proposed SHGC Source Exterior Shading Device Combined SHGC from CF1R ENV -03 E-4050 Sliding Vynil n/a E 2 20 n/a 0.32 T1 10.6-A 0.25 IT1 10.6-A NO N A IL6 15 Total Proposed Fenestration Area 16 Maximum Allowed Fenestration Area 17 Compliance Statement I Total Proposed Fenestration Area <_ Maximum Allowed Fenestration Area ❑ Yes ❑ No 18 Total Proposed West -Facing Fenestration Area 1 0 19 Maximum Allowed West -Facing Fenestration Area N/A 20 Compliance Statement Total Proposed West -Facing Fenestration Areas Maximum Allowed West -Facing Fenestration Area []Yes ❑ No 21 Proposed Fenestration U -factor (Windows) N/A 22 Required Fenestration U -factor (Windows) N/A 23 Compliance Statement I Proposed Fenestration U -factor <_ Required Fenestration U -factor ❑ Yes ❑ No 24 Proposed Fenestration SHGC (Windows) N/A 25 Required Fenestration SHGC (Windows) N/A 26 Compliance Statement I Proposed Fenestration SHGC 5 Required Fenestration SHGC ❑ Yes ❑ No 27 Proposed Fenestration U -factor (Skylights) N/A 28 Required Fenestration 1.1 -factor (Skylights) N/A 29 Compliance Statement I Proposed Fenestration U -factor 5 Required Fenestration U -factor ❑ Yes ❑ No .30 Proposed Fenestration SHGC (Skylights) N/A 31 Required Fenestration SHGC (Skylights) N/A 32 Compliance Statement I Proposed Fenestration SHGC:5 Required Fenestration SHGC ❑ Yes ❑ No CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 7 of 9) Project Name: Martin Enclosure I Date Prepared: 6/22/2017 J. Space Conditioning (SC) Systems — Heating/Cooling (Prescriptive Section 150.2(b)) Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CF1R-ADD-02 and CF2R-ADD-02 Compliance Documents. If new space conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CF111-ADD-01 shall be completed and registered with a HERS Provider Data Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance: ❑ a: space conditioning system was not altered; M b: less than 40 ft of ducts were added or replaced; ❑ c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos; ❑ d: (exempt from duct leakage testing) if: the existing duct system was previously tested and passed by a HERS Rater. 01 02 03 04 Dwelling Unit Name SC System Identification or Name SC System Location or Area Served Exemption from HERS Verification 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13 0 ❑b 0 0 13 a. 0 0 0 0 0 0 0 0 13 0 0 0 0 0 0 0 0 0 0 0 0 13 0 0 0 0 11 0 0 0 11 0 13 13 . ❑d CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 .ETATE.OF CALIFORNIA 0�;' Prescriptive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION — CERTIFICATE OF COMPLIANCE CF111-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 8 of 9) Project Name: Mallin Enclosure I Date Prepared: 6 /2 2 /2 017 K. Water Heating Systems (Section 150.2(a)1D) List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Dwelling Unit Name Water Heating System Identification or Name Water Heating System Location or Area Served Water Heating System Type Water Heater Type q Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insulation R -Value Back -Up Solar Savings Fraction N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A I A CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016 STATE OF CALIFORNIA Prescriotive Residential Additions 300 Ft2 or Less, or Additions That Do Not Require HERS Field Verification 'n CEC-CF1 R ADD 02-E (Revised 04/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions 300 Ft or Less, or Additions That Do Not Require HERS Field Verification (Page 9 of 9) Project Name: Martin Enclosure I Date Prepared: 622/2017 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Rodolfo Lizarde Documentation Author Signature: Company: Rodolfo Lizarde Signature Date: (o — ZZ — I Address: 41-740 Brownstown CEA/ HERS Certification Identification (if applicable): city/state/zip: Bermuda Dunes, CA Phone: 760-285-2027 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of. Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable Inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: _ Rodolfo Lizarde Responsible Designer Signature: Company : Rodolfo Lizarde Date Signed: Address: License: 41-740 Brownstown City/State/Zip: Bermuda Dunes, CA Phone: 760-285-2027 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. CA Building Energy Efficiency Standards - 2016 Residential Compliance April 2016