Loading...
BRES2016-010478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4 XP Qu&Z COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2016-0104 E Property' Address: 44505 VIA DEL MONTE APN: 604203001 Application Description: SPORGIS / INTERIOR REMODEL MAY Property Zoning: Application Valuation: $130,000.00Applicant: DESERT CONCEPTS CONSTRUCTION INC A CALIF 77-770 COUNTRY CLUB DRIVE SUITE D PALM DESERT, CA 92111 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. LicenseClass:: AA, C36, C16, C27, C10. B Lice .• 8498 7 Date: _, L L www, Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (__) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the strucfure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/19/2016 N SPROGIS 3S VIA DEL MONTE WINTA, CA 92253 DESERT CONCEPTS CONSTRUCTION INC A CALIF 77-770 COUNTRY CLUB DRIVE SUITE D PALM DESERT, CA 92111 (760)200-9007 Llc. No.: 849837 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate :)f consent to self -insure for workers' compensation, as provided for by Section 3700 -3f the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the perforrrance of the work for which this permit is issued: My workers' compensation insurance :arrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of tl-e work for which this permit is issued, I shall not employ any person in any manner so a: to become subject to the workers' compensation laws of California,.and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provviisions. Date: 0/P Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR I J SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this applica- ion is made, each person at whose request and for whose benefit work is performec under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Ci -y of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicat on becomes null and void if work is not commenced within 180 days from date of iss.iance of such permit, or cessation of work for 180 days will subject permit to cancellaton. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinaeces and state laws relating to building construction, and hereby authorize representatives o his city nter upon the above-mentioned property for inspection purposas. Date: Signature (Applicant or Ag` DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK -YES 101-0000-42600 1.5 $105.00 $105.00 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT' '. QTY AMOUNT. PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 1.25 $87.50 $87.50 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK ' R15602 19435 TSA Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50 DESCRIPTION ACCOUNT QTY AMOUNT = PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $6.00 $6.00 5/19/16 PAID BY METHOD RECEIPT # = CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $6.00 DESCRIPTION ACCOUNT QTY AMOUNT - PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT = PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 5/19/16 PAID BY METHOD RECEIPT # =- CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 5/19/16 PAID BY METHOD RECEIPT # = CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT = PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $4.83 5/19/16 PAID BY METHOD RECEIPT # _ CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600. 0 $4.83 $4.83 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $12.09 $12.09 5/19/16 PAID By. METHOD RECEIPT #CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID. PAID DATE VENT FAN PC 101-0000-42600 0 $4.83 $4.83 5/19/16 PAID BY METHOD RECEIPT # x CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for MECHANICAL: $50.76 $50.76 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 5/19/16 PAID BY METHOD RECEIPT # _ CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION . ACCOUNT QTY AMOUNT = PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 • TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY- Y-DESERT DESERTCONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101.-0000-42600 0 . $12.09 $12.09. 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for PLUMBING FEES: $120.90 $120.90 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0060-42400 0 $43.50 $43.50 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $34.80 $34.80 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $134.88 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for REMODEL: . $262.49 $262.49 DESCRIPTION ACCOUNT QTY AMOUNT _ PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $16.90 $16.90 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.90 $16.90 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 $60.91 $60.91 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, EA ADDITION 5 101-0000-42400 0 $20.30 $20.30 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK • R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, EA ADDITION 5 PC 101-0000-42600 0 $23.20 $23.20 5/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION I CHECK R15602 19435 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000-42600 0 $110.22 $110.22 5/19/16 PAID BY METHOD RECEIPT # = CHECK # CLTD BY DESERT CONCEPTS CONSTRUCTION 1 CHECK R15602 19435 TSA Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $214.63 $214.63 • • Description: SPORGIS / INTERIOR REMODEL Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: ISSUED Applied: 4/6/2016 SKH Approved: 5/16/2016 JJO Parcel No: 604203001 Site Address: 44505 VIA DEL MONTE LA QUINTA,CA 92253 Subdivision: TR 23971-1 Block: Lot: 81 Issued: 5/19/2016 MFA Lot Sq Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $13D,000.00 Occupancy Type: Construction Type: Expired: 11/15/2016 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 NOTE Details: INTERIOR REMODEL, ADD NEW BATHROOM DOWN STAIRS, REMOVE WALL AND ENLARGE KITCHEN AREA, REMOVE AND REPLACE 3 DOORS AND 14 WINDOWS. PER 2013 CRC CODES 40 3 __j Applied to Approved Approved to Issued Printed: Thursday, May 19, 2016 8:30:54 AM 1 of 5 C9SYSTEMS ADDITIONAL SITES CHRONOLOGY TYPE STAFF NAME CHIRONOLOGY ACTION DATE COMPLETION DATE NOTES NOTE JIM JOHNSON 5/12/2016 5/16/2016 WAITING FOR STRUC PLANS FROM YOUNG, ALSO NEED STRUC CALCS SIGNED BOTH SETS PLAN CHECK COMMENTS FROM CONSULTANT RECEIVED JIM JOHNSON 5/16/2016 5/16/2016 PLAN CHECK PICKED UP STEPHANIE KHATAMI 4/21/2016 4/21/2016 PLAN CHECK PICKED UP TOMMI SANCHEZ 4/22/2016 4/22/2016 PLAN CHEK ITEM PICK UP BY APPLICANT. TELEPHONE CALL JIM JOHNSON 4/21/2016 4/21/2016 CALLED BENJAMIN BELTRAN TO INFORM HIM THE PLANS ARE READY FOR CORRECTIONS T TELEPHONE CALL JIM JOHNSON 5/16/2016 5/16/2016 CALLED BENJAMION BELTRAN TO INFORM HIM THE STRUC CALCS NEED TO BE SIGNED. BEFORE WE ISSUE. CONDITIONS, Printed: Thursday, May 19, 2016 8:30:54 AM 1 of 5 C9SYSTEMS Ok yL.n OF CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE STATUS SATISFIED REMARKS NOTES READY TO ISSUE CHECKLIST JIM JOHNSON 5/16/2016 5/18/2016 COMPLETE CHUCK GARLAND NEEDS TO SIGN STRUC CALCS. BOTH SETS CLTD DESCRIPTION ACCOUNT CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT CONCEPTS CONSTRUCTION INC A CALIF 77-770 COUNTRY CLUB DRIVE PALM DESERT CA 92111 CONTRACTOR DESERT CONCEPTS CONSTRUCTION INCA CALIF 77-770 COUNTRY CLUB DRIVE PALM DESERT CA 92111 5/19/16 R15602 19435 OWNER JOHN SPROGIS 44505 VIA DEL MONTE I LA QUINTA I CA 92253 1 . Printed: Thursday, May 19, 2016 8:30:54 AM 2 of 5' CR SYS TEtriS FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY • BY HOURLY PLAN CHECK - 101-0000-42600 1.5 $105.00 $105.00 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA YES CONSTRUCTION I HOURLY PLAN CHECK - 101-0000-42600 1.25 $87.50 $87.50 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA YES CONSTRUCTION I Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50 BSAS SB1473 FEE 101-0000-20306 0 $6.00 $6.00 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I Total Paid for BUILDING STANDARDS ADMINISTRATION $6.00 $6.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA 1,OOOSF CONSTRUCTION I RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA 1;OOOSF, PC. CONSTRUCTION I Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE 101-0000-424020 $12.09 $12.09 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA REPAIR/ALTERATION CONSTRUCTION I Printed: Thursday, May 19, 2016 8:30:54 AM 2 of 5' CR SYS TEtriS Printed: Thursday, May 19, 2016 8:30:54 AM 3 of 5 SYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY 'BY- BY APPLIANCE 101-0000-42600 0 $4.83 $4.83 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA REPAIR/ALTERATION PC CONSTRUCTION I EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 5/19/16 R15602 19435. CHECK DESERT CONCEPTS TSA CONSTRUCTION I EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I VENT FAN 101-0000-42402 0 $12.09 $12.09 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I VENT FAN PC 101-0000-42600 0 $4.83 $4.83 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I Total Paid for MECHANICAL: " $50.76 $50.76 FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA INST/ALT/REP CONSTRUCTION I WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA INST/ALT/REP PC CONSTRUCTION I Total Paid for PLUMBING FEES: $120.90 $120.90 REMODEL, EA 101-0000-42400 0 $43.50 $43.50 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA ADDITIONAL 500 SF CONSTRUCTION I REMODEL, EA 1ni nnnn-w Finn 0 534.80 $34.80 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA ADDITIONAL 500 SF PC CONSTRUCTION I REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA • CONSTRUCTION I REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA PC CONSTRUCTION I Total Paid for REMODEL: •$262.49 $262.49 Printed: Thursday, May 19, 2016 8:30:54 AM 3 of 5 SYSTEMS NAKEN I NKUJEL I S REVIEW TYPE REVIEWER SENT DATE DUE DATE REVIEWS RETURNED STATUS REMARKS NOTES CLTD DESCRIPTION. ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY 15T BLDG STR (2 JOHN 4/6/2016 4/20/2016 4/19/2016 REVISIONS REQUIRED WK) THOMPSON BY SMI - RESIDENTIAL 101-0000-20308 0 $16.90 $16.90 5/19/16 R15602• 19435 CHECK DESERT CONCEPTS TSA WK) CONSTRUCTION I 2ND BLDG STR (2 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.90 $16.90 DOOR/WINDOW, 101-0000-42400 0 $60.91 $60.91 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA REPLACE FIRST 7 design professional of record. JT 5-13-16 CONSTRUCTION I DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42400 0 $20.30 $20.30 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I 5 DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42600 0 $23.20 $23.20 5/19/16 R15602 19435 CHECK DESERT CONCEPTS TSA CONSTRUCTION I 5 PC DOOR/WINDOW, 101-0000-42600 0 $110.22 $110.22 5/19/16 1115602 19435 CHECK DESERT CONCEPTS TSA REPLACE, FIRST 7 PC CONSTRUCTION I Total Paid for WINDOW/SLIDING GLASS" $214.63 $214.63 DOOR/FENESTRATION: NAKEN I NKUJEL I S REVIEW TYPE REVIEWER SENT DATE DUE DATE REVIEWS RETURNED STATUS REMARKS NOTES DATE IST BLDG NS (2 WK) JIM JOHNSON 4/8/2016 4/20/2018 4/21/2018 REV131ONS REQUIRED 15T BLDG STR (2 JOHN 4/6/2016 4/20/2016 4/19/2016 REVISIONS REQUIRED WK) THOMPSON 2ND BLDG NS (2 JIM JOHNSON 5/2/2016 5/16/2016 5/12/2016 APPROVED WK) 2ND BLDG STR (2 JOHN 5/2/2016 5/16/2016 5/16/2016 READY FOR APPROVAL Structural calculations shall be signed by the WK) THOMPSON - CONDITION design professional of record. JT 5-13-16 Printed: Thursday, May 19, 2016 8:30:54 AM 4 of 5 er SYSTEMS BOND INFORMATION Printed: Thursday, May 19, 2016 8:30:54 AM' 5 of 5 J • SYSTEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/21/2016 JIM JOHNSON 44-505 VIA DEL 44-505 VIA DEL 0 MONTE.docx MONTE.docx 1ST CHECK - 1ST CHECK - DOC 4/19/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 COMMENTS.doc COMMENTS.doc 1ST CHECK - 1ST CHECK - DOC 4/19/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf 2ND CHECK - 2ND CHECK - DOC 5/15/2016 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf. TRANSMITTAL.pdf Printed: Thursday, May 19, 2016 8:30:54 AM' 5 of 5 J • SYSTEMS Bin #C' City of La Quinta Building 8i; Safety Division . _ 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: wner's Name: A. P. Number: Address: Via Legal Description: City, ST, Zip: r7�Z n_ nl Telephone: Contractor:3'> e P Address:77776-1-D... I,` 5u/ Project Description: ^ City, ST, Zip: tni U / Tele h ne•7loo .......Rfoln � a c s r State Lic. #: eityLie.� .Q0+- r Ud�OGtJ S �-- Arch., Engr., Designer:e- W Address:. e [ K 19e 412! City, ST, Zip: 'DI)C-Us trS Telephone: oe tr uction Type: :Con Occu aacY _l State ic.# �b . 8 Project type (circle one): New Add'n A'rter - Repair Demo Name of Contact Person: < < Sq. Ft.: 33Qry # St !es: ## Units: Telephone # of Contact Person: gW-^ 53ca;57 Estimated Value of Project: ovo APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Depo_it Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN I10USE:- Jrd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees YOUNG ENGINEERING S E R V ! C E S Letter of Transmittal To: City of La Quinta Today's Date: 5-13-16 78-495 Calle Tampico City Due Date: 5-16-16 La Quinta, CA 92253 Project Address: 44505 Via Del Monte Attn: Ramses Plan Check #: BRES2016-0104 By: John W. Thompson Office: ® (760) 772-5107 Other: ❑ Submittal: ❑ 1St ❑ 4th ® 2nd ❑ 5th ❑ 3rd ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: Descriptions: Includes: # Of Descriptions: Copies: ❑ Structural Plans ® 1 Revised Struct. Plans ❑ Structural Calculations ® 1 Revised Struct. Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report ❑ Revised Soils Report ® 1 Structural P/C Comments ❑ Approved Structural Plans ® 1 Redlined Structural Plans ❑ Approved Structural Calcs ® 1 Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. Structural calculations shall be signed. Structural Plan Review Time = 1.25 HR This Material Sent for: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson Office: ® (760) 772-5107 Other: ❑ i I BUILDING ENERGY ANALYSIS REPORT PROJECT: SPROGIS RESIDENCE alteration 44505 VIA DEL MONTE LA QUI NTA, CA 92253 CITY OLAF qP/�NA BUILDING&AFE DEPToPPROV R CONSTRUCTION DATE Project Designer: ►RCHITECTURE GROUP INC. 74991 JONI DR #9 ALM DESERT, CA 92260 760 340.3528 Report Prepared by: Armando Chavez TITLE 24 OF THE DESERT SERVICES INC. 74800 SHERYL AVE #62 PALM DESERT, CA 92260 760 278.1840 III M rz Job Number: 2016 -GLS -015 Date: 4/26/2016 RECEIVED MAY 0 2 2016 CIT( OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. THs program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building =nergy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 15 oFRCN /copy J I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R -PRF -01-E Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary CITY F LA, QUIiNTA BUILDING & SAFET��PT. PF'ROV FOR CONSTRUCTION tTE BY EnergyPro 6.7 by EnergySok Job Number: ID: 2016 -GLS -015 -----'—'--User Number: 20648 1 2 3 11 12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Input File Name: 015 -VIAL DEL MONTE ALT..xml CFI R -PRF -01 Pagel of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name SPROGIS RESIDENCE M -p1 +� 04-1 05 02 Calculation Description Title 24 Analysis 08 ` I Ede y tl�s'e (k�TDV ft2_yr) 03 Project Location 44505 VIA DEL MONTE Compliance Margin Percent Improvement 04 City LA QUINTA 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftz) 3373 15 Number of Zones 2 16 Slab Area (W) 2221 17 Number of Stories 2 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (W) 0 21 Glazing Percentage (%) 14.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-26 17:11:58 ENERGY USE SUMMARY M -p1 +� 04-1 05 06 07 08 ` I Ede y tl�s'e (k�TDV ft2_yr) Standard Design Proposed Design Compliance Margin Percent Improvement I I n .$pac Fledin 1.99 1.96 0.03 1.5% I Space)Coo in 173.30 163.09 10.21 5.9% U) IAQ ��tilatio �N � 0.00 0.00 0.00 0.0% �7 VYater"�HeatiVg 8.04 8.04 0.00 0.0% (F3ho 0 of i�cLFff et — 0.00 0.00 ---- C nip is cggy otal 183.33 173.09 10.24 5.6% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Input File Name: 015 -VIAL DEL MONTE ALT..xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY CFI R -PRF -01 Page 2 of 8 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • -- None -- Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 223.79 213.55 10.24 4.6% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION _! -- 1 -C p 1 02 03 04 05 06 07 02 03 04 05 06 07 m Zonee -� Number of Dwelling HVAC System Name (ft2) Number of Ventilation Number of Water Heating Systems Project Name ; Condi Toned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems DHW Sys 1 SPROGIS RESIDENCE 3373 1 5 2 0 1 ZONE INFORM TION (/) ° "° U)�_....._..... _! -- 1 -C p 1 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling m Zonee -� p i -Zo e Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 1st Floo 10ne fil 40bditionecl Res HVAC1 2221 8 DHW Sys 1 2nd Floo one -i >o itioned Res HVAC1 1152 8 DHW Sys 1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation DatefTime: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT..xml CFI R -PRF -01 Page 3 of 8 OPAQUE SURFACES 02 03 04 05 06 07 08 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (W) Tilt (deg) Status Verified Existing Condition N-358 1 st Floor Zone Default Wall 1992 to Pres 0 Right 358 81.3 90 Existing No E-430 1st Floor Zone Default Wall 1992 to Pres 90 Front 430 108.3 90 Existing No S-383 1st Floor Zone Default Wall 1992 to Pres 180 Left 383 18 90 Existing No W-295 1st Floor Zone Default Wall 1992 to Pres 270 Bads 295 182.6 90 Existing No Wall to Garage 1st Floor Zone»_Garage_ (E) R-13 Wall 138 20 Existing No 1069 1 st Floor Zone Default Roof 1978 to Pres Ventilated 4 1069 0.85 No Existing No 240-N 2nd Floor Zone Default Wall 1992 to Pres 0 Right 240 18 90 Existing No 334-E 2nd Floor Zone Default Wall 1978 to 1991 90 Front 334 0 90 Existing No 240-S 2nd Floor Zone Default Wall 1992 to Pres 180 Left 240 28.8 90 Existing No 334-W 2nd Floor Zone Default Wall 1992 to Pres 270 Bads 334 66.6 90 Existing No 1152 2nd Floor Zone Default Roof 1978 to Pres 1152 Existing No G -N-109 _Garage_ (E) Garage Ext Wall 0 Right 128 0 90 Existing No G -E-232 _Garage_ (E) Garage Ext Wall 90 Front 232 128 90 Existing No G -S-198 _Garage_ (E) Garage Ext Wall 180 Left 198 0 90 Existing No G -W-95 _Garage_ (E) Garage Ext Wall 270 Bads 95 16.7 90 Existing No G -R-616 Garage_ Default Roof 1978 to Pres 616 Existing No ATTIC Gr`1 02 03 04 05 06 07 08 09 10 Z Radiant Cool Roof Statu Verified Existing Condition N mem Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier s Attic �GGardge 90 Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Existi ng No C,fl.'� Attic Roof 1st Floor Zone Ventilated 4 0.1 0.85 No No Enioti ng No A(tic 1stTkroorr one; [C ttic 2nd F-faor o C: Attic Roof2nd Floor Zone Ventilated 4 0.1 0.85 No No E�9t� No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT..xml CFI R -PRF -01 Page 4 of 8 WINDOWS 0a 02 03 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Multiplie Width(ft) Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition 2030 N-358 (Right -0) - - 1 6.0 0.32 0.25 Insect Screen (default) Altered N/A 6040 N-358 (Right -0) --- --- 1 24.0 0.32 0.25 Insect Screen (default) Altered N/A 4014 N-358 (Right -0) ---- ---- 1 5.3 0.32 0.25 Insect Screen (default) Altered N/A 4050 N-358 (Right -0) - - 1 20.0 0.32 0.25 Insect Screen (default) Altered N/A 1830 N-358 (Right -0) - -- 1 5.0 1.19 0.68 Insect Screen (default) Existing No 6050 E-430 (Front -90) -- -- 1 30.0 0.32 0.25 Insect Screen (default) Altered N/A 9050 E-430 (Front -90) - --- 1 45.0 0.32 0.25 Insect Screen (default) Altered N/A 5068 E-430 (Front -90) ---- -- 1 33.3 0.32 0.25 Insect Screen (default) Altered N/A 4030 5383 (Left -180) - -- 1 12.0 0.32 0.25 Insect Screen (default) Altered N/A 20302 5383 (Left -180) - - 1 6.0 1.19 0.68 Insect Screen (default) Existing No 12030 W-295 (Back -270) ---- -- 1 36.0 1.19 0.68 Insect Screen (default) Existing No 8068 W-295 (Back -270) ---- - 1 53.3 0.27 0.19 Insect Screen (default) Altered N/A 4040 W-295 (Back -270) --- -- 1 16.0 0.32 0.25 Insect Screen (default) Altered N/A 80682 W-295 (Back -270) ---- --- 1 53.3 0.32 0.25 Insect Screen (default) Altered N/A 60402 W-295 (Back -270) - - 1 24.0 0.32 0.25 Insect Screen (default) Altered N/A 6030 240-N (Right -0) - - 1 18.0 0.32 0.25 Insect Screen (default) Altered N/A ----1640 240-S (Left -180) ---- - 1 6.0 0.32 0.25 Insect Screen (default) Altered N/A i 3666 240-S (Left -180) -- - 1 22.8 0.32 0.25 Insect Screen (default) Altered N/A rri _n 6036_ ._,$ 334-W (Back -270) ---- - 1 21.0 0.32 0.25 Insect Screen (default) Altered N/A -�-i 6'6_3 334-W (Back -270) - 1 22.8 0.71 0.60 Insect Screen (default) Existing No 06E36 2^ ® 334-W (Back -270) - - 1 22.8 0.71 0.60 Insect Screen (default) Existing No s, - Di)lii7 Cn 0a 02 03 04 06 06 awT.�- Side of Building Area (ft2) U -factor Status Verified Existing Condition _ frit D N-358 21.0 0.50 Existing No Z )-On Wall to Garage 20.0 0.50 New No u Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT..xml CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Q v Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Perimeter Carpeted Existing • Inside Finish: Gypsum Board Zone Ceilings (below (ft) Edge Insul. R -value Fraction Heated Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insul. No Existing No • Inside Finish: Gypsum Board • Cavity/ Frame: no insul. / 2x4 • Exterior Finish: Wood (E) Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofl st Floor Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood Default Wall 1992 to Pres Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 (E) R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd-Floor-Zone— Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Dcoo Floor Surface: Carpeted Floor Deck. Wood Siding/sheathing/decking I -D Cavity/Frame: no insul. /2x12 (E) R-0 FIooK o7C awl'sp W Interior Floors Wood Framed Floor 2x12 @ 16 in. O.C. none 0.196 Ceiling Below Finish: Gypsum Board WZ0 Inside Finish: Gypsum Board OCavity/Frame: R-11 /2x4 ,,�� = G99a Exterior Finish: Wood D fa It Wall f9 8=t)1 E7StOrIOr WaIIS W44d Fr�metl Wall 2x4 (a3 16 in. O.C. R 11 0.103 Siding/sheathing/decking !1 = t 1 y --*1 SLA LOORSG < M 02 03 04 05 06 07 08 09 Q v Verified Perimeter Carpeted Existing Name -.4 > Zone Area (ft) (ft) Edge Insul. R -value Fraction Heated Status Condition 2221 1 st Floor Zone 2221 90 None 0.8 No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Datefrime: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- CF1 R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control ew Sys 1 n/a n/a n/a n/a n/a Na I = r— ® I SPACE C � DITION�NG�S- S J 0 U �2 03 04 05 06 07 08 09 O --� Heating System Cooling System Z 90 Distribution Fan Floor Area Verified Existing Na m U� 6SYS{S 8 Name Ducted Name Ducted System System Served Status Condition Res H 1 C: at' a d Heating 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 3373 Existing No Cooli 'st Component Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT..xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE CF1 R -PRF -01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 9.6 9.7 No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 2.1 Attic Attic None Existing No N/A System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016 Calculation Description: Title 24 Analysis Input File Name: 015 -VIAL DEL MONTE ALT..xml CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Armando Chavez Company: Signature Date: TITLE 24 OF THE DESERT SERVICES INC. 4/26/2016 Address: CEA/HERS Certification Identification (If applicable): 74800 SHERYL AVE #62 City/stateIJALM DESERT, CA 92260 Phone: 760 278.1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible D ner igndire: RUBEN ROMERO Company: Date Signed GLS ARCHITECTURE GROUP INC. Address: License: r-74991--JONI-DR#97j City/State2ip: Phone: PFALM eESE T, -C -A 2260 760 340.3528 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-26 17:11:58 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name SPROGIS RESIDENCE alteration Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ AdditioniAlteration Date 412612016 Project Address 44505 VIA DEL MONTE LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,373 Addition 0 # of Units 1 INSULATION Construction Type Cavity Area (ft) Secial Features Status Roof Wood Framed Attic R 19 2,221 Existing Slab Unheated Slab -on -Grade - no insulation 2,221 Perim = 90' Existing Wall Wood Framed R 13 1,776 Existing Door Opaque Door - no insulation 21 Existing Demising Wood Framed R 13 118 Existing Demising Wood Framed wio Crawl Space - no insulation 1,152 Existing Wall Wood Framed R11 334 Existing FENESTRATION I Total Area: 483 Glazing Percentage: 14.3%1New/Altered Average U -Factor: 0.31 Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (N) 73.3 0.320 0.25 none none Bug Screen Altered Right (N) 5.0 1.190 0.68 none none Bug Screen Existing Front (E) 108.3 0.320 0.25 none none Bug Screen Altered Left (S) 40.8 0.320 0.25 none none Bug Screen Altered Left (S) 6.0 1.190 0.68 none none Bug Screen Existing Rear (Vtq 36.0 1.190 0.68 none none Bug Screen Existing Rear (VIq 53.3 0.270 0.19 none none Bug Screen Altered Rear (VIq 114.3 0.320 0.25 none none Bug Screen Altered Rear (V19 45.6 0.710 0.60 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R• -Value Status Res HVAC Ducted Ducted Attic 0 Existin _IT l]Imly� �nl & SAFETY WATER HEATING Qty. Type Gallons Min. Eff Distribution liPPROV� ' tus BY EnerqyPro 6.7 by EnerqySoft User Number.' 20648 RunCode: 2016-04-26T17:13:01 ID: 2016 -GLS -015 Pae 11 of 15 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aDDroach used. ExceDtions may anDly. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 11.0.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. §I 10.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF 1 R. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § ] 50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-] 9 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §I50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class 1 or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §I50.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §I50.0(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)]: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirempjt .= f 1. ,(f §150.0(j)lA: Storage gas water heaters with an energy factor equal to or less than the federil,fninimum t dar h 1 t rnall wrap ed with insulation havingan installed thermal resistance of R-12 or greater. ❑ i 11 _ FETY DEBT. §150.0(j)1B: Unfired hot water tanks such as storage tanks and backup storage tanks for solar water-beatingpst v xternal insulation or R-16 internal insulation where the internal insulation R -value is indicated on threteiSr-d"fe For domestic hot water system piping, whether buried or unburied: the first 5 feet of IS,DDt,=gn ' o � WN, story tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation sy tem §] 50.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, pipin�yburied below grade, d all hot water pipes from the heating source to kitchen fixtures must be insulated'according to the reod tents. T euT c ' ' 3- A. §150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.06)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing enc approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l : with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building mus* have backdraft or automatic dampers. §I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simult e$$u�Iy }d livenng, ontrol mode, from dwelling, handler fan delivered I� § 150.0(m)15: an airflow the through the air and to the d elPa�g! qf3 eo o fcoomcapacity, and operating at an air -handling unit fan efficacy of< 0.58 W/CFM a coir i d);y field ve�fi'cdti A `�i�rJ'NG testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Nether wind Yvyop q� t ra ion § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systemsfatuPe ssssihlei> �� o� ding the Whole BuildingVentilation. riff § 150.0(0)1 A: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accor an ith Reference Residential Appendix RA3. 1 DAT Pool and Spa Heating Systems and Equipment Measures: - -� Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § l 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: §110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k) I C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § I50.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § I50.0(k)20: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it §I50.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. §I50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the lumi ireless than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gas t u iit uq�in sing §I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned s ace s a d i as c allow ballast maintenance and replacement without requiring cutting holes in the ceili g. BUILDING �A X For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy f r compli c �wi tals"P shall be certified to the Energy Commission to comply with the applicable re uireme sin l l For single-family residential buildings, outdoor lighting permanently mounted to a re identialQ'4 Si i same lot shall be high efficacy, or may be low efficacy if it meets all of the following equirements:U V 1 1 i. Controlled by a manual ON and OFF switch that does not override to ON the auto aR actions of Items ii or iii below; and §I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables th&Ation sen_ sor or cWolled by a motion sensor having a temporary override switch which temporarily bypasses the motion-sensing-4nc reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in 110.9 130.0, 130.1, 130.4, 140.6, and 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)1213: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §I 10.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § l 10.10 e . §I 10.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §I10.10(b) through §I10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 1 10.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal pTiection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. §1 10.10(d): A copy of the construction documents or a comparable document indicating the information from §1 10.10(b) through §1 10.10(c) shall be provided to the occupant. §110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a §I 10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and 2ermanently marked as "For Future Solar Electric'.