BRES2016-010478-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
4 XP Qu&Z
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BRES2016-0104 E Property' Address: 44505 VIA DEL MONTE
APN: 604203001
Application Description: SPORGIS / INTERIOR REMODEL MAY
Property Zoning: Application Valuation: $130,000.00Applicant:
DESERT CONCEPTS CONSTRUCTION INC A CALIF
77-770 COUNTRY CLUB DRIVE
SUITE D
PALM DESERT, CA 92111
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
LicenseClass:: AA, C36, C16, C27, C10. B Lice .• 8498 7
Date: _, L L www, Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(__) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the strucfure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( ) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/19/2016
N SPROGIS
3S VIA DEL MONTE
WINTA, CA 92253
DESERT CONCEPTS CONSTRUCTION INC A CALIF
77-770 COUNTRY CLUB DRIVE
SUITE D
PALM DESERT, CA 92111
(760)200-9007
Llc. No.: 849837
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate :)f consent to self -insure for workers'
compensation, as provided for by Section 3700 -3f the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the perforrrance of the work for which this permit
is issued: My workers' compensation insurance :arrier and policy number are:
Carrier: _ Polity Number: _
I certify that in the performance of tl-e work for which this permit is issued, I
shall not employ any person in any manner so a: to become subject to the workers'
compensation laws of California,.and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provviisions.
Date: 0/P Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR I J SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this applica- ion is made, each person at whose
request and for whose benefit work is performec under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Ci -y of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this applicat on becomes null and void if work is
not commenced within 180 days from date of iss.iance of such permit, or cessation of
work for 180 days will subject permit to cancellaton.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinaeces and state laws relating to building
construction, and hereby authorize representatives o his city nter upon the
above-mentioned property for inspection purposas.
Date: Signature (Applicant or Ag`
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK -YES
101-0000-42600
1.5 $105.00
$105.00
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT' '.
QTY
AMOUNT.
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
1.25
$87.50
$87.50
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK '
R15602
19435
TSA
Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
= PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$6.00
$6.00
5/19/16
PAID BY
METHOD
RECEIPT #
= CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $6.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
- PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.03
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
= PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$47.86
5/19/16
PAID BY
METHOD
RECEIPT #
=- CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$12.09
5/19/16
PAID BY
METHOD
RECEIPT #
= CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
= PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.83
$4.83
5/19/16
PAID BY
METHOD
RECEIPT #
_ CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600.
0
$4.83
$4.83
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$12.09
$12.09
5/19/16
PAID By.
METHOD
RECEIPT #CHECK
#
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID.
PAID DATE
VENT FAN PC
101-0000-42600
0
$4.83
$4.83
5/19/16
PAID BY
METHOD
RECEIPT #
x CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for MECHANICAL: $50.76 $50.76
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$48.36
$48.36
5/19/16
PAID BY
METHOD
RECEIPT #
_ CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION .
ACCOUNT
QTY
AMOUNT
= PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$48.36
$48.36
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
• TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
$12.09
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY-
Y-DESERT
DESERTCONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101.-0000-42600
0
. $12.09
$12.09.
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for PLUMBING FEES: $120.90 $120.90
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0060-42400
0
$43.50
$43.50
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$34.80
$34.80
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$134.88
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for REMODEL: . $262.49 $262.49
DESCRIPTION
ACCOUNT
QTY
AMOUNT
_ PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$16.90
$16.90
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.90 $16.90
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE FIRST 7
101-0000-42400
0
$60.91
$60.91
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, EA ADDITION 5
101-0000-42400
0
$20.30
$20.30
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK •
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, EA ADDITION 5
PC
101-0000-42600
0
$23.20
$23.20
5/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION I
CHECK
R15602
19435
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, FIRST 7 PC
101-0000-42600
0
$110.22
$110.22
5/19/16
PAID BY
METHOD
RECEIPT #
= CHECK #
CLTD BY
DESERT CONCEPTS CONSTRUCTION 1
CHECK
R15602
19435
TSA
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $214.63 $214.63
• •
Description: SPORGIS / INTERIOR REMODEL
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: ISSUED
Applied: 4/6/2016 SKH
Approved: 5/16/2016 JJO
Parcel No: 604203001 Site Address: 44505 VIA DEL MONTE LA QUINTA,CA 92253
Subdivision: TR 23971-1 Block: Lot: 81
Issued: 5/19/2016 MFA
Lot Sq Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $13D,000.00 Occupancy Type: Construction Type:
Expired: 11/15/2016 MFA
No. Buildings: 0 No. Stories: 0 No. Unites: 0
NOTE
Details: INTERIOR REMODEL, ADD NEW BATHROOM DOWN STAIRS, REMOVE WALL AND ENLARGE KITCHEN AREA, REMOVE AND REPLACE 3
DOORS AND 14 WINDOWS. PER 2013 CRC CODES
40 3
__j Applied to Approved
Approved to Issued
Printed: Thursday, May 19, 2016 8:30:54 AM 1 of 5
C9SYSTEMS
ADDITIONAL SITES
CHRONOLOGY TYPE
STAFF NAME
CHIRONOLOGY
ACTION DATE COMPLETION DATE
NOTES
NOTE
JIM JOHNSON
5/12/2016
5/16/2016
WAITING FOR STRUC PLANS FROM YOUNG, ALSO NEED
STRUC CALCS SIGNED BOTH SETS
PLAN CHECK COMMENTS
FROM CONSULTANT
RECEIVED
JIM JOHNSON
5/16/2016
5/16/2016
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
4/21/2016
4/21/2016
PLAN CHECK PICKED UP
TOMMI SANCHEZ
4/22/2016
4/22/2016
PLAN CHEK ITEM PICK UP BY APPLICANT.
TELEPHONE CALL
JIM JOHNSON
4/21/2016
4/21/2016
CALLED BENJAMIN BELTRAN TO INFORM HIM THE PLANS ARE
READY FOR CORRECTIONS
T
TELEPHONE CALL
JIM JOHNSON
5/16/2016
5/16/2016
CALLED BENJAMION BELTRAN TO INFORM HIM THE STRUC
CALCS NEED TO BE SIGNED. BEFORE WE ISSUE.
CONDITIONS,
Printed: Thursday, May 19, 2016 8:30:54 AM 1 of 5
C9SYSTEMS
Ok yL.n
OF
CONDITION
TYPE
CONTACT
DATE
ADDED
DATE
REQUIRED
DATE STATUS
SATISFIED
REMARKS
NOTES
READY TO ISSUE
CHECKLIST
JIM JOHNSON
5/16/2016
5/18/2016 COMPLETE
CHUCK GARLAND NEEDS TO SIGN STRUC CALCS.
BOTH SETS
CLTD
DESCRIPTION
ACCOUNT
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
DESERT CONCEPTS CONSTRUCTION
INC A CALIF
77-770 COUNTRY CLUB
DRIVE
PALM DESERT
CA
92111
CONTRACTOR
DESERT CONCEPTS CONSTRUCTION
INCA CALIF
77-770 COUNTRY CLUB
DRIVE
PALM DESERT
CA
92111
5/19/16
R15602
19435
OWNER
JOHN SPROGIS
44505 VIA DEL MONTE
I LA QUINTA
I CA
92253
1 .
Printed: Thursday, May 19, 2016 8:30:54 AM 2 of 5' CR
SYS TEtriS
FINANCIAL INFORMATION
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
•
BY
HOURLY PLAN CHECK -
101-0000-42600
1.5
$105.00
$105.00
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
YES
CONSTRUCTION I
HOURLY PLAN CHECK -
101-0000-42600
1.25
$87.50
$87.50
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
YES
CONSTRUCTION I
Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50
BSAS SB1473 FEE
101-0000-20306
0
$6.00
$6.00
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
Total Paid for BUILDING STANDARDS ADMINISTRATION
$6.00 $6.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$145.03
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
1,OOOSF
CONSTRUCTION I
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
1;OOOSF, PC.
CONSTRUCTION I
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
APPLIANCE
101-0000-424020
$12.09
$12.09
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
REPAIR/ALTERATION
CONSTRUCTION I
Printed: Thursday, May 19, 2016 8:30:54 AM 2 of 5' CR
SYS TEtriS
Printed: Thursday, May 19, 2016 8:30:54 AM 3 of 5
SYSTEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
'BY- BY
APPLIANCE
101-0000-42600
0
$4.83
$4.83
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
REPAIR/ALTERATION PC
CONSTRUCTION I
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
5/19/16
R15602
19435.
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
VENT FAN
101-0000-42402
0
$12.09
$12.09
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
VENT FAN PC
101-0000-42600
0
$4.83
$4.83
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
Total Paid for MECHANICAL: " $50.76 $50.76
FIXTURE/TRAP
101-0000-42401
0
$48.36
$48.36
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
FIXTURE/TRAP PC
101-0000-42600
0
$48.36
$48.36
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
WATER SYSTEM
101-0000-42401
0
$12.09
$12.09
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
INST/ALT/REP
CONSTRUCTION I
WATER SYSTEM
101-0000-42600
0
$12.09
$12.09
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
INST/ALT/REP PC
CONSTRUCTION I
Total Paid for PLUMBING FEES: $120.90 $120.90
REMODEL, EA
101-0000-42400
0
$43.50
$43.50
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
ADDITIONAL 500 SF
CONSTRUCTION I
REMODEL, EA
1ni nnnn-w Finn
0
534.80
$34.80
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
ADDITIONAL 500 SF PC
CONSTRUCTION I
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
•
CONSTRUCTION I
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$134.88
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
PC
CONSTRUCTION I
Total Paid for REMODEL: •$262.49 $262.49
Printed: Thursday, May 19, 2016 8:30:54 AM 3 of 5
SYSTEMS
NAKEN I NKUJEL I S
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
REVIEWS
RETURNED STATUS
REMARKS
NOTES
CLTD
DESCRIPTION.
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
15T BLDG STR (2
JOHN
4/6/2016
4/20/2016
4/19/2016
REVISIONS REQUIRED
WK)
THOMPSON
BY
SMI - RESIDENTIAL
101-0000-20308
0
$16.90
$16.90
5/19/16
R15602•
19435
CHECK
DESERT CONCEPTS
TSA
WK)
CONSTRUCTION I
2ND BLDG STR (2
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $16.90 $16.90
DOOR/WINDOW,
101-0000-42400
0
$60.91
$60.91
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
REPLACE FIRST 7
design professional of record. JT 5-13-16
CONSTRUCTION I
DOOR/WINDOW,
REPLACE, EA ADDITION
101-0000-42400
0
$20.30
$20.30
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
5
DOOR/WINDOW,
REPLACE, EA ADDITION
101-0000-42600
0
$23.20
$23.20
5/19/16
R15602
19435
CHECK
DESERT CONCEPTS
TSA
CONSTRUCTION I
5 PC
DOOR/WINDOW,
101-0000-42600
0
$110.22
$110.22
5/19/16
1115602
19435
CHECK
DESERT CONCEPTS
TSA
REPLACE, FIRST 7 PC
CONSTRUCTION I
Total Paid for WINDOW/SLIDING GLASS"
$214.63 $214.63
DOOR/FENESTRATION:
NAKEN I NKUJEL I S
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
REVIEWS
RETURNED STATUS
REMARKS
NOTES
DATE
IST BLDG NS (2 WK)
JIM JOHNSON
4/8/2016
4/20/2018
4/21/2018
REV131ONS REQUIRED
15T BLDG STR (2
JOHN
4/6/2016
4/20/2016
4/19/2016
REVISIONS REQUIRED
WK)
THOMPSON
2ND BLDG NS (2
JIM JOHNSON
5/2/2016
5/16/2016
5/12/2016
APPROVED
WK)
2ND BLDG STR (2
JOHN
5/2/2016
5/16/2016
5/16/2016
READY FOR APPROVAL
Structural calculations shall be signed by the
WK)
THOMPSON
- CONDITION
design professional of record. JT 5-13-16
Printed: Thursday, May 19, 2016 8:30:54 AM 4 of 5 er
SYSTEMS
BOND INFORMATION
Printed: Thursday, May 19, 2016 8:30:54 AM' 5 of 5 J •
SYSTEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/21/2016
JIM JOHNSON
44-505 VIA DEL
44-505 VIA DEL
0
MONTE.docx
MONTE.docx
1ST CHECK -
1ST CHECK -
DOC
4/19/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
COMMENTS.doc
COMMENTS.doc
1ST CHECK -
1ST CHECK -
DOC
4/19/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
TRANSMITTAL.pdf
TRANSMITTAL.pdf
2ND CHECK -
2ND CHECK -
DOC
5/15/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
TRANSMITTAL.pdf.
TRANSMITTAL.pdf
Printed: Thursday, May 19, 2016 8:30:54 AM' 5 of 5 J •
SYSTEMS
Bin #C'
City of La Quinta
Building 8i; Safety Division
. _ 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: wner's Name:
A. P. Number: Address: Via
Legal Description: City, ST, Zip: r7�Z
n_ nl Telephone:
Contractor:3'>
e P
Address:77776-1-D... I,` 5u/ Project Description:
^
City, ST, Zip: tni U /
Tele h ne•7loo
.......Rfoln
� a c s r
State Lic. #: eityLie.�
.Q0+- r Ud�OGtJ S �--
Arch., Engr., Designer:e- W
Address:. e [ K 19e 412!
City, ST, Zip:
'DI)C-Us trS
Telephone: oe tr uction Type:
:Con
Occu aacY
_l
State ic.# �b .
8 Project type (circle one): New Add'n A'rter - Repair Demo
Name of Contact Person: < < Sq. Ft.: 33Qry # St !es: ## Units:
Telephone # of Contact Person: gW-^ 53ca;57 Estimated Value of Project: ovo
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Depo_it
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2"" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN I10USE:-
Jrd Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
YOUNG
ENGINEERING
S E R V ! C E S
Letter of Transmittal
To: City of La Quinta Today's Date: 5-13-16
78-495 Calle Tampico City Due Date: 5-16-16
La Quinta, CA 92253 Project Address: 44505 Via Del Monte
Attn: Ramses Plan Check #: BRES2016-0104
By: John W. Thompson
Office: ® (760) 772-5107
Other: ❑
Submittal: ❑
1St
❑
4th
®
2nd
❑
5th
❑
3rd
❑
Other:
We are forwarding: ® By Messenger
❑
By Mail (Fed Ex or UPS)
❑ Your Pickup
Includes:
Descriptions:
Includes:
# Of
Descriptions:
Copies:
❑
Structural Plans
®
1
Revised Struct. Plans
❑
Structural Calculations
®
1
Revised Struct. Calcs
❑
Truss Calcs
❑
Revised Truss Calcs
❑
Soils Report
❑
Revised Soils Report
®
1 Structural P/C Comments
❑
Approved Structural Plans
®
1 Redlined Structural Plans
❑
Approved Structural Calcs
®
1 Redlined Structural Calcs
❑
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
❑
Other:
Comments:
Structural content is approvable. Structural calculations shall be signed.
Structural Plan Review Time = 1.25 HR
This
Material Sent for:
❑ Your Files
®
Per Your Request
❑ Your Review
❑
Approval
❑ Checking
❑
At the request of:
Other: ❑
By: John W. Thompson
Office: ® (760) 772-5107
Other: ❑
i
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
SPROGIS RESIDENCE alteration
44505 VIA DEL MONTE
LA QUI NTA, CA 92253
CITY
OLAF qP/�NA
BUILDING&AFE DEPToPPROV
R
CONSTRUCTION
DATE
Project Designer:
►RCHITECTURE GROUP INC.
74991 JONI DR #9
ALM DESERT, CA 92260
760 340.3528
Report Prepared by:
Armando Chavez
TITLE 24 OF THE DESERT SERVICES INC.
74800 SHERYL AVE #62
PALM DESERT, CA 92260
760 278.1840
III M rz
Job Number:
2016 -GLS -015
Date:
4/26/2016
RECEIVED
MAY 0 2 2016
CIT( OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. THs program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building =nergy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
15
oFRCN /copy
J
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R -PRF -01-E Certificate of Compliance
Form RMS -1 Residential Measures Summary
Form MF -1 R Mandatory Measures Summary
CITY F LA, QUIiNTA
BUILDING & SAFET��PT.
PF'ROV
FOR CONSTRUCTION
tTE BY
EnergyPro 6.7 by EnergySok Job Number: ID: 2016 -GLS -015 -----'—'--User Number: 20648
1
2
3
11
12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Input File Name: 015 -VIAL DEL MONTE ALT..xml
CFI R -PRF -01
Pagel of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name SPROGIS RESIDENCE
M -p1 +� 04-1
05
02
Calculation Description Title 24 Analysis
08
` I Ede y tl�s'e (k�TDV ft2_yr)
03
Project Location 44505 VIA DEL MONTE
Compliance Margin
Percent Improvement
04
City LA QUINTA
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftz) 3373
15
Number of Zones 2
16
Slab Area (W) 2221
17
Number of Stories 2
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (W) 0
21
Glazing Percentage (%) 14.3%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider:
Report Generated at: 2016-04-26 17:11:58
ENERGY USE SUMMARY
M -p1 +� 04-1
05
06
07
08
` I Ede y tl�s'e (k�TDV ft2_yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
I I n .$pac Fledin
1.99
1.96
0.03
1.5%
I Space)Coo in
173.30
163.09
10.21
5.9%
U) IAQ ��tilatio
�N �
0.00
0.00
0.00
0.0%
�7 VYater"�HeatiVg
8.04
8.04
0.00
0.0%
(F3ho 0 of i�cLFff et
—
0.00
0.00
----
C nip is cggy otal
183.33
173.09
10.24
5.6%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider:
Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Input File Name: 015 -VIAL DEL MONTE ALT..xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
CFI R -PRF -01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• -- None --
Cooling System Verifications:
• -- None --
HVAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
• --None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 223.79 213.55 10.24 4.6%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
_! --
1 -C p 1 02 03 04 05 06 07
02
03
04
05
06
07
m
Zonee -�
Number of Dwelling
HVAC System Name
(ft2)
Number of Ventilation
Number of Water
Heating Systems
Project Name ;
Condi Toned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
DHW Sys 1
SPROGIS RESIDENCE
3373
1
5
2
0
1
ZONE INFORM TION (/) ° "° U)�_....._.....
_! --
1 -C p 1 02 03 04 05 06 07
Zone Floor Area
Avg. Ceiling
m
Zonee -�
p i -Zo e Type
HVAC System Name
(ft2)
Height
Water Heating System 1
Water Heating System 2
1st Floo 10ne
fil 40bditionecl
Res HVAC1
2221
8
DHW Sys 1
2nd Floo one
-i >o itioned
Res HVAC1
1152
8
DHW Sys 1
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider:
Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation DatefTime: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT..xml
CFI R -PRF -01
Page 3 of 8
OPAQUE SURFACES
02
03
04
05
06
07
08
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (W)
Tilt
(deg)
Status
Verified
Existing
Condition
N-358
1 st Floor Zone
Default Wall 1992 to Pres
0
Right
358
81.3
90
Existing
No
E-430
1st Floor Zone
Default Wall 1992 to Pres
90
Front
430
108.3
90
Existing
No
S-383
1st Floor Zone
Default Wall 1992 to Pres
180
Left
383
18
90
Existing
No
W-295
1st Floor Zone
Default Wall 1992 to Pres
270
Bads
295
182.6
90
Existing
No
Wall to Garage
1st Floor Zone»_Garage_
(E) R-13 Wall
138
20
Existing
No
1069
1 st Floor Zone
Default Roof 1978 to Pres
Ventilated
4
1069
0.85
No
Existing
No
240-N
2nd Floor Zone
Default Wall 1992 to Pres
0
Right
240
18
90
Existing
No
334-E
2nd Floor Zone
Default Wall 1978 to 1991
90
Front
334
0
90
Existing
No
240-S
2nd Floor Zone
Default Wall 1992 to Pres
180
Left
240
28.8
90
Existing
No
334-W
2nd Floor Zone
Default Wall 1992 to Pres
270
Bads
334
66.6
90
Existing
No
1152
2nd Floor Zone
Default Roof 1978 to Pres
1152
Existing
No
G -N-109
_Garage_
(E) Garage Ext Wall
0
Right
128
0
90
Existing
No
G -E-232
_Garage_
(E) Garage Ext Wall
90
Front
232
128
90
Existing
No
G -S-198
_Garage_
(E) Garage Ext Wall
180
Left
198
0
90
Existing
No
G -W-95
_Garage_
(E) Garage Ext Wall
270
Bads
95
16.7
90
Existing
No
G -R-616
Garage_
Default Roof 1978 to Pres
616
Existing
No
ATTIC Gr`1
02
03
04
05
06
07
08
09
10
Z
Radiant
Cool Roof
Statu
Verified Existing
Condition
N mem
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
s
Attic �GGardge 90
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Existi
ng
No
C,fl.'�
Attic Roof 1st Floor Zone
Ventilated
4
0.1
0.85
No
No
Enioti
ng
No
A(tic 1stTkroorr one;
[C
ttic 2nd F-faor o C: Attic Roof2nd Floor Zone
Ventilated
4
0.1
0.85
No
No
E�9t�
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT..xml
CFI R -PRF -01
Page 4 of 8
WINDOWS
0a
02
03
01
02
03 04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Multiplie
Width(ft) Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
2030
N-358 (Right -0)
- - 1
6.0
0.32
0.25
Insect Screen (default)
Altered
N/A
6040
N-358 (Right -0)
--- --- 1
24.0
0.32
0.25
Insect Screen (default)
Altered
N/A
4014
N-358 (Right -0)
---- ---- 1
5.3
0.32
0.25
Insect Screen (default)
Altered
N/A
4050
N-358 (Right -0)
- - 1
20.0
0.32
0.25
Insect Screen (default)
Altered
N/A
1830
N-358 (Right -0)
- -- 1
5.0
1.19
0.68
Insect Screen (default)
Existing
No
6050
E-430 (Front -90)
-- -- 1
30.0
0.32
0.25
Insect Screen (default)
Altered
N/A
9050
E-430 (Front -90)
- --- 1
45.0
0.32
0.25
Insect Screen (default)
Altered
N/A
5068
E-430 (Front -90)
---- -- 1
33.3
0.32
0.25
Insect Screen (default)
Altered
N/A
4030
5383 (Left -180)
- -- 1
12.0
0.32
0.25
Insect Screen (default)
Altered
N/A
20302
5383 (Left -180)
- - 1
6.0
1.19
0.68
Insect Screen (default)
Existing
No
12030
W-295 (Back -270)
---- -- 1
36.0
1.19
0.68
Insect Screen (default)
Existing
No
8068
W-295 (Back -270)
---- - 1
53.3
0.27
0.19
Insect Screen (default)
Altered
N/A
4040
W-295 (Back -270)
--- -- 1
16.0
0.32
0.25
Insect Screen (default)
Altered
N/A
80682
W-295 (Back -270)
---- --- 1
53.3
0.32
0.25
Insect Screen (default)
Altered
N/A
60402
W-295 (Back -270)
- - 1
24.0
0.32
0.25
Insect Screen (default)
Altered
N/A
6030
240-N (Right -0)
- - 1
18.0
0.32
0.25
Insect Screen (default)
Altered
N/A
----1640
240-S (Left -180)
---- - 1
6.0
0.32
0.25
Insect Screen (default)
Altered
N/A
i 3666
240-S (Left -180)
-- - 1
22.8
0.32
0.25
Insect Screen (default)
Altered
N/A
rri _n 6036_ ._,$
334-W (Back -270)
---- - 1
21.0
0.32
0.25
Insect Screen (default)
Altered
N/A
-�-i 6'6_3
334-W (Back -270)
- 1
22.8
0.71
0.60
Insect Screen (default)
Existing
No
06E36 2^ ®
334-W (Back -270)
- - 1
22.8
0.71
0.60
Insect Screen (default)
Existing
No
s, -
Di)lii7 Cn
0a
02
03
04
06
06
awT.�-
Side of Building
Area (ft2)
U -factor
Status
Verified Existing Condition
_ frit D
N-358
21.0
0.50
Existing
No
Z )-On
Wall to Garage
20.0
0.50
New
No
u
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT..xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Q v
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Perimeter
Carpeted
Existing
• Inside Finish: Gypsum Board
Zone
Ceilings (below
(ft)
Edge Insul. R -value
Fraction
Heated
Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
Over Floor Joists: R-9.9 insul.
No
Existing
No
• Inside Finish: Gypsum Board
• Cavity/ Frame: no insul. / 2x4
• Exterior Finish: Wood
(E) Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.302
Siding/sheathing/decking
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofl st Floor Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
Default Wall 1992 to Pres
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
(E) R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2nd-Floor-Zone—
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Dcoo
Floor Surface: Carpeted
Floor Deck. Wood Siding/sheathing/decking
I -D
Cavity/Frame: no insul. /2x12
(E) R-0 FIooK o7C awl'sp
W
Interior Floors
Wood Framed Floor
2x12 @ 16 in. O.C.
none
0.196
Ceiling Below Finish: Gypsum Board
WZ0
Inside Finish: Gypsum Board
OCavity/Frame:
R-11 /2x4
,,�� = G99a
Exterior Finish: Wood
D fa It Wall f9 8=t)1
E7StOrIOr WaIIS
W44d Fr�metl Wall
2x4 (a3 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
!1 = t 1 y --*1
SLA LOORSG < M
02
03
04
05
06
07
08
09
Q v
Verified
Perimeter
Carpeted
Existing
Name -.4 >
Zone
Area (ft)
(ft)
Edge Insul. R -value
Fraction
Heated
Status
Condition
2221
1 st Floor Zone
2221
90
None
0.8
No
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation Datefrime: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT.xml
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
CF1 R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.575 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01 02
03
04
05
06
07
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
ew Sys 1 n/a
n/a
n/a
n/a
n/a
Na
I = r— ® I
SPACE C � DITION�NG�S- S J
0
U �2
03
04
05
06
07
08
09
O --�
Heating System
Cooling System
Z 90
Distribution
Fan
Floor Area
Verified Existing
Na m
U� 6SYS{S 8
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Res H 1
C: at' a d
Heating
1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan
1
3373
Existing
No
Cooli 'st
Component
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT..xml
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
CF1 R -PRF -01
Page 7 of 8
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
9.6
9.7
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
2.1
Attic
Attic
None
Existing
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-04-26 17:11:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SPROGIS RESIDENCE Calculation Date/Time: 17:11, Tue, Apr 26, 2016
Calculation Description: Title 24 Analysis
Input File Name: 015 -VIAL DEL MONTE ALT..xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Armando Chavez
Company:
Signature Date:
TITLE 24 OF THE DESERT SERVICES INC.
4/26/2016
Address:
CEA/HERS Certification Identification (If applicable):
74800 SHERYL AVE #62
City/stateIJALM DESERT, CA 92260
Phone:
760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible D ner igndire:
RUBEN ROMERO
Company:
Date Signed
GLS ARCHITECTURE GROUP INC.
Address:
License:
r-74991--JONI-DR#97j
City/State2ip:
Phone:
PFALM eESE T, -C -A 2260
760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-04-26 17:11:58
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
SPROGIS RESIDENCE alteration
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ AdditioniAlteration
Date
412612016
Project Address
44505 VIA DEL MONTE LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,373
Addition
0
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Secial Features Status
Roof Wood Framed Attic R 19
2,221 Existing
Slab Unheated Slab -on -Grade - no insulation
2,221 Perim = 90' Existing
Wall Wood Framed R 13
1,776 Existing
Door Opaque Door - no insulation
21 Existing
Demising Wood Framed R 13
118 Existing
Demising Wood Framed wio Crawl Space - no insulation
1,152 Existing
Wall Wood Framed R11
334 Existing
FENESTRATION I Total Area: 483 Glazing Percentage: 14.3%1New/Altered Average U -Factor: 0.31
Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status
Right (N) 73.3 0.320
0.25 none
none Bug Screen Altered
Right (N) 5.0 1.190
0.68 none
none Bug Screen Existing
Front (E) 108.3 0.320
0.25 none
none Bug Screen Altered
Left (S) 40.8 0.320
0.25 none
none Bug Screen Altered
Left (S) 6.0 1.190
0.68 none
none Bug Screen Existing
Rear (Vtq 36.0 1.190
0.68 none
none Bug Screen
Existing
Rear (VIq 53.3 0.270
0.19 none
none Bug Screen Altered
Rear (VIq 114.3 0.320
0.25 none
none Bug Screen Altered
Rear (V19 45.6 0.710
0.60 none
none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R• -Value Status
Res HVAC Ducted
Ducted
Attic 0
Existin
_IT
l]Imly� �nl
& SAFETY
WATER HEATING
Qty. Type Gallons Min. Eff Distribution liPPROV�
'
tus
BY
EnerqyPro 6.7 by EnerqySoft User Number.' 20648
RunCode: 2016-04-26T17:13:01 ID: 2016 -GLS -015
Pae 11 of 15
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance aDDroach used. ExceDtions may anDly. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 11.0.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§I 10.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF 1 R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ ] 50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-] 9 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class 1 or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§I50.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)113:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)]:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i):
Heating systems are equipped with thermostats that meet the setback requirempjt .= f 1. ,(f
§150.0(j)lA:
Storage gas water heaters with an energy factor equal to or less than the federil,fninimum t dar h 1 t rnall wrap ed
with insulation havingan installed thermal resistance of R-12 or greater. ❑ i 11 _ FETY DEBT.
§150.0(j)1B:
Unfired hot water tanks such as storage tanks and backup storage tanks for solar water-beatingpst v xternal
insulation or R-16 internal insulation where the internal insulation R -value is indicated on threteiSr-d"fe
For domestic hot water system piping, whether buried or unburied: the first 5 feet of IS,DDt,=gn ' o � WN, story
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation sy tem
§] 50.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, pipin�yburied below grade, d
all hot water pipes from the heating source to kitchen fixtures must be insulated'according to the reod tents. T euT c ' ' 3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.06)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing enc approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l :
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building mus* have backdraft or automatic
dampers.
§I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simult e$$u�Iy }d livenng, ontrol mode,
from dwelling, handler fan delivered I�
§ 150.0(m)15:
an airflow the through the air and to the d elPa�g! qf3
eo o fcoomcapacity,
and operating at an air -handling unit fan efficacy of< 0.58 W/CFM a coir i d);y field ve�fi'cdti A
`�i�rJ'NG
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Nether wind Yvyop q� t ra ion
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systemsfatuPe ssssihlei> �� o� ding the
Whole BuildingVentilation. riff
§ 150.0(0)1 A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accor an ith
Reference Residential Appendix RA3. 1 DAT
Pool and Spa Heating Systems and Equipment Measures: - -�
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§I 10.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ l 10.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k) I C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ I50.0(k)20:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the lumi ireless than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gas t u iit uq�in sing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned s ace s a d i as c
allow ballast maintenance and replacement without requiring cutting holes in the ceili g. BUILDING
�A X
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy f r compli c �wi tals"P
shall be certified to the Energy Commission to comply with the applicable re uireme sin l l
For single-family residential buildings, outdoor lighting permanently mounted to a re identialQ'4 Si i
same lot shall be high efficacy, or may be low efficacy if it meets all of the following equirements:U V 1 1
i. Controlled by a manual ON and OFF switch that does not override to ON the auto aR actions of Items ii or iii below; and
§I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables th&Ation sen_ sor or cWolled by a
motion sensor having a temporary override switch which temporarily bypasses the motion-sensing-4nc
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9 130.0, 130.1, 130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)1213:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§I 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § l 10.10 e .
§I 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §I10.10(b) through §I10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 1 10.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal pTiection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§1 10.10(d):
A copy of the construction documents or a comparable document indicating the information from §1 10.10(b) through §1 10.10(c)
shall be provided to the occupant.
§110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§I 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and 2ermanently marked as "For Future Solar Electric'.