07331 (SFD)Buildin
Address 44-410 Via Del Sot
Owner
Heart#' from
Mailing
Address 15 Augusta fir.
citymncho Mirage zip 92270
Contractor
Saw
Address
Zip
P 0 BOX 1504
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
Tel.
321-8004
State Lic. I City
& Classif. 509208 Lic. #
Arch., Engr.,
Designer
Address Tel.
k
City Zip .11:.-.`!k,"., State
Lic. #
LICENSED CONTRACTOR'S DECLARATION '
I here ftaffirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Divisiiotn•3 o-f�the,llusiness and?Professions Code, and my license is in full force and
effect.SIGNATURE 'V DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractors License Law for the following
reason: (Sec. 7031.5.Busoness and Professions Code: Any city or county which requires a.
permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than rive hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will .
do the work, and the structure is not intended or offered for sale. (Sec. 7044• Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such 4nprovements are not intended or offered for sale. M however, the building
or improvement is sold within one year of completion, the owner -budder wig have the burden
ofproving that he did not build or improve for the purpose of sale.)
❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project (Sec. 7044, Business and Professions Code: The. Contractor's License Law
does not apply to an owner of property who builds or improves thereon• and who contracts for
such projects with a contractors) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Workers compensation Insurance, or a certified co y.thereof.^(Sec. 380.0; Labor Code.)
PolicyNo44 Q-`01 fvl. °Company tit'T QJ t1r:
❑ Copy is filed with the city.. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California
Date Owner
NOTICE TO APPLICANT: -lf, after making this Certificate or Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
Ihereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lenders Name
Lenders Address
' This is a building permit when.propedy filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days. .
I certity that I have read this application and state that the above information is correct.
I'agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the -above-.
mentioned property for inspection purposes:
Signature of applicant Date'
Mailing Address
City,. State, Zip
No. ®7331
11LDING:TYPE CONST. - OCC: GRP. -
P. Number 613-$02-004* 009, 010
egal Description Tentative Tract. 23971 tot 7
roject Description $F
nth 4.•f11-1. if; Uq$: M. -i-3-70 10
r! CA314 I TOTAL 97
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop"Lihe
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:.' Date 3/13/9 Permit
Validated by:
Validation: __
Sq.
Size' -'1360
No.
Stories
No. Dw.
Units -
New ❑ Add ❑
Alter ❑
Repair ❑ Demolition ❑
Estimated Valuation
$171,350
71,30
PERMIT
AMOUNT
Plan Chk. Dep.
MAW
Plan Chk. Bal.
Const.
s
Mech.
Electricalt3.bG
Plumbing
15U. v
S.M.I.
1244
Grading
Driveway Enc.
Infrastructure
sad•'
TOTAL
REMARKS
f Yd✓y !
a a 1tr Y.
~ . r•.r x w.sf "� a
'44 A,
nth 4.•f11-1. if; Uq$: M. -i-3-70 10
r! CA314 I TOTAL 97
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop"Lihe
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:.' Date 3/13/9 Permit
Validated by:
Validation: __
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING.F5ES
1ST FL. SO. FT. ® $
UNITS
COLL. AREA
SLAB GRADE 3 '
Q�
YARD SPKLR SYSTEM
2ND FL. Sp. FT.
HEATING (ROUGH)
STORAGE TANK
FORMS
MOBILEHOME SVC.
BAR SINK
POR. $p, FT. ®
DUCT WORK
ROCK STORAGE
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
METER LOOP
HEATING (FINAL)
DRAINAGE PIPING
CAR P. I SO. FT. ®
GAS (FINAL)
WALL Sp. FT.
DRINKING FOUNTAIN.
Sp FT ®
URINAL
ESTIMATED CONSTRUCTION VALUATION $
FINAL INSP.
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
GRADING
cu. yd.
$ plus x$
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD '
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
wf u/
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
REMARKS:
LAUNDRY TRAY
AIR HANDLING UNIT CFM
4 -
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
SO.FT.GAR ® 3/ac
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
OUND PLUMBING3
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE 3 '
Q�
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
ER OR SE
ROUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF� o%O
9Q
GAS (ROUGH) � _G��
(G�
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
-$
LUMBER GR. FINAL INSP
FRAMING FINAL INSP.
ROOFING
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
rcr.irc cu�wi
wf u/
REMARKS:
0
4 -
SIGNATUREWINITIALS
GARDEN WALL FINAL
V
fi
!R1
. . ........
OF
(Ou*nit a
l,u
This Certificate issued pqrsuant-t6 the requirements of Section 306 of the Uniform Building
Code certifying that at the time of issuance this structure was in compliance'with the various
ordinances of theCity regulating building construction or use.,, For the following.
BUILDING ADDRESS' 44-410 Via Del Sol'
Single Family Dwelling
Use,Classification Bldg. Permit No. 07331
R3 Type Constrtiction ire Zone SR
.Group F Use Zone
Owner,of Building Deane Homes Address 15 Augusta Drive
c1tv RanchQ Mirag.��A Mark Harold
By;
Date; April 29, 1993
Building Official
POST IN A CONSPICUOUS PLACE
I
I
-COMPUTER METHOD SUMMARY
PEge 1 C=2R
Project Title,.......... DALE THORNBURGH
Dcte.'....... 04/22/93
Project Address......... 44410 VIA DEL SOL
-----=---------------
LA QUINTA
Docume'ntation.Author ... W J,.FINNELL
; Building Permit #
Company. ... ...... Energy Consulting Group
Telephone. ... .......... 1-800-262-9966
;_Plan Check /.Date
Compliance Method...... MICROPAS4 by Enercomp, Inc.
r ,
;,Field Check/ Date
Climate Zone........... 15
MTCROPAS4 v4.01 File-DALE2 Wth-CTZ15S92 Program-F"ORM
C -2R
. ; User#--MP1325 User -Energy Consulting Group
Run-DALE2 _
- MICROPAS4 ENERGY USE SUMMARY
=
= Energy.Use Standard Proposed
Compliance =
_ (kBtu/sf-yr) DesignDesign-
Margin =
- Space Heating.......... 4.05 3.89
0.16 =
= Space Cooling. ... ... 36.33 32.36
3.97 -
- Total 40.38 36.25
4.13 -
- *** Water Heating not calculated,***
-
GENERAL TNFORMATION
Conditioned Floor Area..... 560 sf
Building Type.....,. ..... Single'Family
Detached
Construction Type ......... Ne'w
Building Front Orientation. Front Facing 180
-deg (S)
Number of Dwelling Units... .28
Number of Building Stories. 1
Weather Data Type.:...,... ReducedYear,
Floor Const'ruction Type .... Slab On Grade
( Package ,D )
Number of Building Zones... 1
Conditioned Volume.....,.... 4480.cf
Footprint Area...... ..... 153 sf
Ground Floor Area. ........ 153 sf.
Slab-On.=Grade Area ......... 1'53 sf
Glazing Percentage......... 2.9 %,of FA
Average Ceiling Height..... 8 ft
COMPUTER
METHOD SUMMARY Page 2 C -2R
Project
Title..........
DALE THORNBURGH Date........ 04/22/93
MICROPAS4 v4.01 :File=DALE2 Wth-CTZ15S92 Program -FORM C -2R
-------------------------------------------------------------------------------
User#-MP1325
User -Energy Consulting Group Run-DALE2
BUILDING ZONE INFORMATION
Floor
# of : Vent Special
Area
Volume Dwell Cond- Thermostat Height Vent .Area
Zone Type.
(sf)
(cf) Units itioned Type (ft) (sf)'
HOUSE
Residence
560
4480" 0.28 Yes Setback 2.0 n/a
OPAQUE SURFACES
Area
---------------
U- Insul Act Solar Form 3 Location/
Surface`
(sf)
value R -vat Azm Tilt Gains Reference Comments
HOUSE_
I Wall
224
0.065 R-19 180 90 Yes W.19.2X6.16 OUTSIDE
2 Wall
125
0.065 R-19 270 90 Yes W.19.2X6.16 OUTSIDE
3 Wall
165
0.06.5 R-19 90 90 Yes "W.19.2X6.1e OUTSIDE
4'Roof
'560
0.025 R-38"" 0 0 Yes R.38.2X4.24 ATTIC.
5 Door
40
0.330 R-0 270 90 Yes None OUTSIDE.
6 Door
32
0.330 R-0 0 90 No None HOUSE
7 Door.
168
0.143.R-7 180 90 Yes None OUTSIDE
PERIMETER LOSSES
Length
----------------
F2 Insul
Surface
(ft) Factor R-val Location/Comments
HOUSE
8 SlabEdge
66 0:900 R-0 OUTSIDE
FENESTRATION SURFACES
---------------------
SC Sc- Interior
Area # of
Frame Open U- Act Glass Int Shade
Surface
(sf) Panes
Type Type value Azm Tilt Only Shade Description
HOUSE
1 Window
16.0 2
Metal Slider 0.87 90 90 0..88 0.58 Blinds.Lt
THERMAL MASS
Area
------------
Thick Heat Conduct- Surface.
Mass Type
(sf.).
.(in) Cap ivity R—value Locat_on/Comments
HOUSE
1 S1abOnGrade
153
3.*5 28.0 0..98 R-0.0 EXPOSED
COMPUTER "METHOD SUMMARY
., r
`�< $Page 3C
-2R
Project.Title.........
DALE THORNBURGH
�. ^�
Date . ..`` 04%22/93
MICROPAS4 v4701
File-DALE2� Wth-CTZ15S92
Program-FORM}C-2R-
User#;MP1325 User-Ener.gy'Consulting
Group,•.Run-DALE2
---- -------'---------------------------
-----------
------------ '-
-
:HVAC,
SYSTEMS
1 - f tj
• -- ---------
'
Minimum
Duct'
w
Duct .',,Ductz +
System Type
Efficiency -.,Location{','R-value
ficiency,
HOUSE
' Furnace
0.780 AFUE
Attic
R-5.2 - .'0.835 t
ACSplit.
10.00 SEER •--Attic;
R-5 .2 y' ` `0.820
SPECIAL'-FEATURES/REMARKS
- •
-
,
. w
•' •~�.. '
t T � ` i
,
4;. '-
t
i, h. .� , f � .. _
.dam ' ..
,� ,
i ' •
''
. r'
;
`
Vit'
�
— . •
• r
.e' syr
, .,
Y
.•e t` • �
• -p
*' .." i., v
�,
HVAC SIZING Pcge 1 HVAC
Project Title.......... DALE THORNBURGH Date........ 04/22/93
Project Address........ 44410 VIA DEL SOL -------------=-------
LA QUINTA
Documentation Author... cW J FINNELL ; Building Permit.#
Company... .*Energy Consulting Group
Telephone. ....... 1-800-262-9966 ; Plan Check / Date ;
Compliance Method ....... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15 ---------------------
------------
MICROPAS4`v4.01 File-DALE2 Wth-CTZ15S92 Program -HVAC SIZING- --- -
User#-MP1325 User -Energy Consulting Group Run-DALE2
GENERAL INFORMATION
Floor Area ................. 560 sf
Volume ............ ........ 4480 cf
Front Orientation.......... Front Facing 180 deg (S)
Sizing Location...... ..... INDIO
Latitude...., ............. 33.7 degrees
Winter Outside Design...... 29 F
Winter Inside.Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range .........:..... 30 F
Interior Shading Used.::.. No
Exterior Shading Used....... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such, as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
Heating
Cooling
Description
( Btuh.)
( Btuh )
Opaque Conduction and Solar......
6341
.3296
.Glazing Conduction ...............
571
473
Glazing Solar .......... .........
n/a
895
Infiltration .....................
2642
1566
Internal Gain ....................
n/a
336
Ducts ..............................
955
657
Sensible Load....... ...........
10508
7223
Latent Load......... ...........
n/a
1445
Minimum Total Load
10508
8667
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such, as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL PF.ge 1 CF -1R
Project Title ........... DALE THORNBURGH DEte........ 04/22/93
Project Address.....,... 44410 VIA DEL SOL ---------------------
LA QUINTA
Documentation.Author... W J FINNELL Building Permit ,#
Company.. ............. Energy Consulting Group
Telephone_. ........... 1-800-262-9966 ;, Plan Check / Date.,:
Compliance Method...... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15 ----------------------
---------------- -------------
MICROPAS4 v4.01 File-DALE2 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1325 User -Energy Consulting Group Rur-DALE2
GENERAL INFORMATION
Conditioned Floor Area..... .560 sf
Building -Type. ........... Single Family Detached
Construction,Type New
Building Front Orientation. Front Facing 180 deca (S)
Number of Dwelling Units...', .28
Number of Stories.... ... 1
Floor Construction 'Type ..... Slab On Grade (Package D)
BUILDING SHELL INSULATION
Component
Insulation
Assembly
TIermostat
Type
R -value
U' -Value
Location/Comments
Wall
R-19
0.065
OUTSIDE
Roof
R-38
0.025
ATTIC
Door
R-0
0.330
OUTSIDE, HOUSE
Door
R-7
0.143
OUTSIDE
S1abEdge
R-0
0.900
OUTSIDE
FENESTRATION
Over -
Area U- # of Interior Exterior hang/ Framing
Orientation (sf) Value Panes Shading Shading _,Fins Type.
--------
'Window Right (E) 16.0 0.870 2 Blinds.Lt None None Metal
Type Exposed
S1abOnGrade Yes
THERMAL MASS
------------
Area' Thickness
(sf) (in)
153 3.5
HVAC SYSTEMS
Location/Comments
------------------------
EXPOSED
Minimum
Duct
Duct
TIermostat
Equipment Type Efficiency
Location.
R -value
Type
Furnace 0.780 AFUE
Attic
R-5.2
S6tback
ACSplit 10.00 SEER
Attic
R-5.2
Setback
.CERTIFICATE OF COMPLIANCE. RESIDENTIAL Page,2 CF -1R
Project Title.. ... ..DALE THORNBURGH Date.,....... 04/22/93
MICROPAS4'.v4.`O1 File-DALE2' Wth-CTZ15S92' Program-FORM'CF-1R
User#-MP1325,, User-Energy,Consulting:Group Run-DAL'E2 ;•'
SPECIAL FEATURES/,REMARKS--
-------------------------
COMPLIANCE
EATURES/,REMARKS` ------------- ---COMPLIANCE STATEMENT
---------------------
.,,,This certificate'of-compliance lists the building ,features and performance
specifications' needed ..to comply with Title -24,' Parts I' and '6 . of the.
California' Code of.Regulations, and the administrative -regulations. to
implement them..' This certificate has been signed by the ,'.individual with,
overall- design responsibility . -When th'i's certificate of compliance is_
submitted for a,single building -,plan to be built in multiple• orientations,,
'any .shading feature that fs.varied is indicated in the Special Features/
Remarks section. ,
DESIGNER or OWNER DOCUMENTAT=ON AUTHOR'
Name`. Name.... W J,FINNELL
Company:, - Company. Energy. Consulting Group.
-
Address , Address. 61880 Indian Hill Rd #'34F.
r' .Mtn. Center, CA 92561'
Phone.., Phone... 1-800-262=9966
License,
Signed.`.Signed.
' ( date) date)
ENFORCEMENTAGENCY
Name.
Title.
Agency..
Phone... .
gency,-
Phone... .
Signed... -t
(date)
,
- ' moi• ..
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF•'iR
-Project Title.........Y. DALE THORNBURGH, Date........ 04/22/93
Project Address........ 44410 VIA DEL SOL-------------. ----
LA QUINTA
Documentation Author... W J FINNELL ; Building Permit #
.Company ................ Energy Consulting Group
Telephone ........::.... 1-800-262-9966 ; Plan Check / Date
Compliance Method ....... MICROPAS4 by Enercomp, Inc ; Field Check/ Date
Climate Zone.....`...... 15---------------------
' MICROPAS4 v4.01 File7DALE2 Wth-CTZ15S92 Program-FORM MF-1R
" User#-MP1325 .User-Energy Consulting Group ,Run-DALE2
----------------------- ------------- ----------------------.-___- __---_________
y
Lowrise ,residential buildings subject. to,the Standards must contain these
measures regardless of the compliance approach used. Items marked with'. an
asterisk (*) may be superseded by more stringent compliance Irequirements listed,
on the. Certificate of Compliance. `When this checklist is incorporated into the
permit "documents', the features noted shall be considered by.� al°1 parties as
binding minimum component performance specifications for the mandator.y'measures
whether they-are shown elsewhere in the documents.or on this checklist only.-
BUILDING ENVELOPE MEASURES
---------------- -----------
- Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation i
150(b):-Loose fill insulation manufacturers labeled •R-Value.
*150(c): Mi`nimum R-13 wall insulration in framed walls -
( does not apply to exterior mass walls)'.
*150(d):"M.'inimum R-13 raised floor' insulation in framed floors;
minimum R-8 in concrete raised floors.
150(i): Slab edge,insulation - water absorption rate no grE:ater
than 0.3 water vapor transmission raterno-greater than 2.0
Perm/Inch.
118: Insulation specified or'installed meets CEC`qual�ity,
standards'. Indicate type anal form. _
116-17: Fenestration•Products, Exterior Doors and Infiltration/
exfiltration controls
a. Doors and windows between conditioned and unconditioned
spaces designed to.limit air leakage
b., Manufactured fenestration products have label with:-
certified U-value, and,infiltration certification. ,
c. Exterior doors and.windows weatherstripped; all-joints
and penetrations caulked and.sealed.
150(-8): Vapor barriers mandatory in Climate Zones 14 and 1E.
only.
150( f ): Special' infiltration barrier, installed to comply Ath•,;
Sec. 151 meets CEC quality'standards. r
15O(e): Installation of Fireplaces,�Decorative-Gas Applianc=es
f-afid gas ..logs
1..Masonry and factory-built`fireplaces'have: ;
a . Closeable metal 'or. glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed. '
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
Project Title........ DALE THORNBURGH Date........ 04/22/93
MICROPAS4 v4.01- File-DALE2 Wth-CTZ15S92, Program -FORM MF -1R
User#-MP1325 User -Energy Consulting Group Run-DALE2
-------------------------------------------------------------------------------
SPACE.CONDITIONING, WATER'HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce-
er menu
110-13: HVAC equipment, water heaters, showerheads and faucets
.certified by the CEC.
150(i): Setback thermostat on all applicable heating systens..
150(j )= Pipe and Tank insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or
backup solar hot water tanks) have insulation blanket (R-12
or greater) or -combined interior/exterior insulation (R-16
or greater ) .
2. First '5 feet of pipes closest to water heater tank, non
recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating
sections of hot water system.
4. -Cooling system piping below 55 degrees insulated.
S.' Piping insulated between heating source and indirect
hot water tank.
*150(m)': Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC
sections 1002 and 1004; ducts insulated to a minimum
installed value of R-4.2 or ducts enclosed entirely w=thin-
conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers.
3: Gravity ventilating systems serving conditioned space have
either automatic or readily.accessible, manually
operated dampers.
114: Pool and Spa,Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric,
resistance'heat.ing and no pilot light.
2. System installed with:
a. At least 36 inches pipe between filter and heater=or
future solar heating.
b. Cover for outdoor pools or outdoor spa:
3. Pool system has directional inlets and a circulation
pump -time switch.
115: Gas-fired central furnace, pool heater, spa heater or
household cooking appliance have no continuously burning
pilot light (Exception: Non -electrical cooking appliance
with pilot < 150 Btu/hr.. )
LIGHTING MEASURES
------------------
Design Enforce-
er ment
150(k): 40 lumen/watt or greater for general lighting in
kitchens and rooms with water closets; and recessed ceiling
fixtures IC (insulation cover) approved.