Loading...
BMCH2017-044278-495 CALUJAMPICO . T. D �NM�iil/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: MECHANICAL/ Application Number: BMCH2O17-0442 Property Address: 78410 VIA DIJON APN: 604610002 Application Description: MCCLURE / HVAC CHANGEOUT 17SEER/81AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $20,090.00 Applicant: i' /A f7 CERTIFIED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET , INDIO, CA 92201 OCT 0 3 20 17 CITYOFLAQUINTA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class- C20 C36 License No.: 906115 Date: Cont�o OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_J I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/3/2017 Owner: MICHAEL MCCLURE 78410 VIA DIJON LA QUINTA, CA 92253 Contractor: CERTIFIED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET INDIO, CA 92201 (760)360-2202 Llc. No.: 906115 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EVEREST NATIONAL INSURANCE COMPANY Policy Number: 7600015264 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with ose provisions. Date: App—lic'ant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the aboveiT;w y for inspection purposes. DaeSignature.(AppliEant o Agent): Application.Number_ .:',;,#1M91,2017-0442 Property Address: 78410 VIA DIJON APN: 604610002 Application Description: MCCLURE / HVAC CHANGEOUT 17SEER/81AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $20,090.00 Applicant: CERTIFIED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET INDIO, CA 92201 Date: 10/3/2017 Owner: MICHAEL MCCLURE 7841C VIA DIJON LA QL INTA, CA 92253 Contr3ctor: CERTI=IED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET INDIC, CA 92201 (760)360-2202 Llc. N:).: 906115 -------------------------------------------------------------------------------------------- Detail: HVAC CHANGE OUT- (2)17SEER/81AFUE SPLIT SYSTEWCARBON MONOXIDE ALARM(S) TO -BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL } .'DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $78.02 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $156.04 Total Paid lfor CHANGEOUT: $234.06 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS:4. Bin # Permit •# M(tt s1 Project Address:' A. P. Number: Legal Description: rr j Contractor: � 2v �! t'/ ri Address: City, ST, Zip: CO.-, Telephone: 7j G 0 — State Lic. # : q (Jc, Arch., Engr., Designer: Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: Telephone # of Contact Person: # Submittal Plan Sets Structural Calcs. Truss Calcs. Energy Calcs. Flood plain plan Gradingplan' Subcontactor List Grant Deed H.O.A. Approval IN HOUSE: - Planning Approval Pub. ScWks. APpr hool Fees City of La Quinta Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet 0 Owner's Name: . J'� Address: 9%,% 11 City' ST' Zip: Q� 1'. e� $ M5 Y,1 Telephone: _ (� Project Description: Lic. #: `-f i -L Construction Type: Occupancy: Project type (circle one): New Add, Alter Repair' Demo Sq. Ft: # Stories: # Units: Estimated Value of Project -11 10 0- CI o APPLICANT: DO NOT WRITE BELOW THIS UNE Ree'd TRACKING . PERMIT FEES Plan Check submitted Item Amount Reviewed, ready for corrections Plan Check Deposit Called Contact Person Plan Check Balance Plans picked up Construction Plans resubmitted Mechanical 2' Review, ready for correciions/issue Electrical Called Contact Person Plumbing Plans picked up S.ML Plans resubmitted Grading Review, ready for corrections/issue Developer -impact Fee Called Contact Person A LP.P. Date of permit issue Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of 3) Project Name: 78410 Via Dijon . Date Prepared: 2017-30-02 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name 78410 Via Dijon 02 Date Prepared 2017-10-02 03 Project Location 78410 Via Dijon 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 78410 Via Dijon iL I_- TA SC System Dwelling Unit Conditioned CFA served 07 Zip Code 92253 08 Floor Area (ft2) 2763 Identification or Location or Area by this SC Number of Space containing 09 Climate Zone 15 10 Conditioning (SC) Systems in 2 Served System (ft) system? component? this Dwelling Unit: feet of ducts? B. Space Conditioning (SC) System Information ( { I� it r`�, ;„ o l r j i ; i t Ol 02 03 04 ... .05 X06 _. 07 , �V, 0 8 :'69 �-� 10 is the SCS— I staIIi &a • > i iL I_- TA SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than.40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Living Area 1200 Yes Yes Yes No No No Altered spaceconditioning system System 2 Bedrooms 1200 Yes Yes Yes No No No Altered space . conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020339885A-000-000-0000000-0000 Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Schema Version: rev 10/16 2017-10-02 07:34:23 _ HERS Provider: CalCERTS Report Generated: 2017-10-02 10:34:35 CERTIFICATE OF COMPLIANCE CF1R-ALT-02=E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)IE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central split All new Central split All new This field or This field or System 1 HF heating AFUE 81 AC cooling SEER 17 Setback section is not section is not components components applicable applicable Central split All new Central split All new This field or This field or System 2 HP heating AFUE 81 AC cooling SEER 17 Setback section is not section is not components components applicable applicable, RequiredDocumentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 10% leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification, required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. + - Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage.Testing requirements. ir 1 1 E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 217-A020339885A-000-000-0000000-0000 Registration Date/Time: 2017-10-02 07:34:23 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-10-02 10:34:35 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF4R-ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: // J Hyde, Mark �pj�ILP/ Company: Signature Date: CERTIFIED COMFORT SYSTEMS INC 2017-10-02 07:34:23 Address: CEA/ MER] Cei tlflLAGun IJenGfiLutiuri (if opplicoblo): 42949 Madio City/State/Zip: Phone: Indio CA 92201 760-360-2202 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). . 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations F. ?'{ _ 4. The building design features or system design features identified ort this Certificate of Compliance are consistent with the information provided on otherapplicable compliance documents, worksheets, calculations, plans and specifications submittdd to the enfotcement agency for approval with this builds g permit applicatign• 5. 1 will ensure that a registered copy of this Certificate of.Compliance shalfbe.made.available with;the building permits) issued for the building, and made available to the'gnforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is,required to be included with the documentation, he builder prow des to the building owner at occupancy. Responsible Designer Name: "A f ? f 3 1 _ Responsible Designer Signature: V Hyde, Mark Company: Date Signed: CERTIFIED COMFORT SYSTEMS INC 2017-10-02 07:34:23 Address: License: 42949 Madio 906115 City/State/Zip: Phone: Indio CA 92201 760-360-2202 Easy to Verify NMI. at.CaICERTS.com N, r p);Fk' � 5 Digitally signed b CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies 9 Y 9 Y 9 9, P 9 Y P w Registration Provider responsibility for the accuracy of the information. � ❑ Registration Number: 217-A020339885A-000-000-0000000-0000 Registration Date/Time 2017-10-02 07:34:23 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: ZQ16.1.006 Report'Generated: 2017-10-02 10:34:35 Schema Version: rev 10/16