Loading...
07-3250 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT T__C7-00003.250 53034 VIA DONA 772-410-999-13 -298944- DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL' 484018 Architect or Engineer: PIP LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 671203 Date:ntractor:. - - OWNER -BUILDER DECLARATION . I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to " construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or . that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant .for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and ' the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The / _ Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one-year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _) I, as owner of the property, am, exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - - (_) I am exempt under Sec. ,.B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/31/08 Owner: GARY & DIANE LOHMAN Contractor: PIERCE CORPORATIOtRjANU^���P.O. BOX 3420PALM DESERT, CA 9 (760)346-3228 FIMA LA6lliIN tic. No.: 671203 EL,8pr ------------------ WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Cbde, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier DELOS INS CO Policy Number 01DKRM12003819 I certify that, in the performance of the work for which this permit is issued, I shall not employ any, person in any manner so as to become subject to the workers' compensation laws of California, . and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. plicant: WARNING: FAILURE TO'SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for - whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. - I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives . of thi/s county to enter up a above-mentioned property for,inspection purposes. pd{e: ignature (Applicant or Agent): - LQPERMIT Application Number . . . . 07-00003250 ----_-- *Structure Information 5,446SF DWELLING/V-NR/RES-3/CLASS A -FR ----- Other struct info . . . . . CODE EDITION 2001/2004/2005 # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 840.00 PATIO SQ FTG 2069.00 ---------------------------------------------------------------------------- NUMBER OF UNITS •1.00 Permit BUILDING PERMIT , Additional desc . Permit Fee . . . . 1987.00 Plan Check Fee 1291.55 Issue Date Valuation 484018 Expiration Date .6/28/09 Qty Unit Charge Per Extension BASE FEE 639.50 385.00 3.5000 THOU BLDG 100,001-500,000 1347.50 Permit . . . . MECHANICAL Additional desc . Permit Fee 162.50 Plan Check Fee 40.63 Issue Date . . . Valuation . . 0 Expiration Date ". .6/28/09. Qty Unit Charge Per, Extension BASE FEE, 15.00 2.00' 9.0000 EA MECH FURNACE <=100K 18.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 1.00 4.51000 EA MECH VENT•INST/ DUCT ALT 4.50 2.00 9.0000 EA 'MECH B/C-<=3HP/100K BTU 18.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 •6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . 220.61 Plan Check Fee 55.15 Issue Date Valuation 0 Expiration Date 6/28/09 Qty. Unit Charge Per Extension BASE FEE 15.00 5446.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 190.61 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 LQPERMIT LQPERMIT Application Number . . . 07-00003250 Permit . . . PLUMBING Additional desc Permit Fee 252.75 Plan Check Fee .. 63.19 Issue Date Valuation . . . . 0 Expiration Date 6/28/09 Qty- Unit Charge Per Extension BASE FEE, 15.00 25:00 6.0000 EA PLB FIXTURE 150.00 1.00 15.-0000 -EA PLB BUILDING SEWER 15.00 5.00 6.0000 EA PLB ROOF DRAIN 30.00 1.00 7.5000 EA' PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA. PLB WATER INST/ALT/REP 3.00 1.00 9.0,000 EA PLB LAWN SPRINKLER SYSTEM 9.00 11.00 .7500 EA PLB GAS PIPE >=5 8.25 1.00 15.0000 EA PLB GAS METER 15.00 Permit .. GRADING PERMIT Additional desc Permit Fee. . . 15.00 Plan .Check Fee .00 Issue Date . . . . Valuation . . . . 0' Expiration Date - 6/28/09 Qty Unit Charge ..Per Extension BASE FEE- 15.00 --------------------------------------------------- ------------------------- Special Notes and Comments -------- 5,.446SF DWELLING/V-NR/RES-3/CLASS A -FR THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL, SPA, WATER -FEATURES OR DRIVEWAY APPROACH. (2) DETACHED CASITAS.APPROVED PER HIDEAWAY SPECIFIC DEVELOPMENT PLAN. 2001 CALIFORNIA BUILDING, MECHANICAL,' - PLUMBING, 2004 ELECTRICAL, 2005.ENERGY CODES APPROVED BY AO FOR JIM JOHNSON. December 30, 2008 4:13:10 PM AORTEGA Other Fees . . . ART IN PUBLIC PLACES -RES. ,710.04. DIF COMMUNITY CENTERS -RES 74-00 DIF CIVIC'CENTER - RES 995.00 --ENERGY- •REVIEW --FEE DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 LQPERMIT Application Number . . . . . 07-00003250 ------=---------------------------------------------------------------------- ' Other Fees . . . . . . . . . DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES- 892.00 STRONG MOTION (SMI) - RES 48.40 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due Permit Fee Total 2637.86 .00 00 2637.86 Plan Check Total 1450.52 7.50.00 .00 700.52 , Other Fee Total 5377.60 .00 .00 5377.60 Grand Total 9465.98 750.00 .00 8715.98 i . LQPERMIT - T74 P.O. BOX 1504 Building 78-495 CALLE TAMPICO Address 51® o V iA, LA QUINTA, CALIFORNIA 92253 ,i r' i' i' /.c 'I' CityZip Tel. State Lica City & Classif.AA fiLf Lic. #44 L Designer ��� �g j W_M1?=M1% M110 -11t LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT 07-- 32SZ7 APPLICATION ONLY BUILDING: TYPE CONST. tz- * OCC. GRP. A.P. Number III - W- ®`' - �z Legal Description Project Description Sq. Ft. No. Size Sto No. Dw. New l< Add ❑ Alter ❑ Repair ❑ Demolition ❑ ' Estimated Valuation 2. ox. ®. D® PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Eno, Infrastructure TOTAL REMARKS �} AMOUNT i ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE ( I APPLICATION# ADD - .ESS EY t VALUATION. SQ . F7. UNIT COUNTS lst FLOOR p TOILETS 2�d FLOOR BIDET . COVERED PATIO � SFi'OWERS GARAGE. I BATHTUBS. . TYPE CONST SINKS OCCUPANCY° BAR SINK A/ C' - -. FIRE SPRINKLER.ilD 0V #. OF BEDROOMFq TRANGE { FLOOD ZONE .. COOKTC # OF Ii3IT5 �; DR.TNi INC. FOUN ' CODE EDITIONola 64 1 t66 WASHER ROOF TYPE . -.DRYER WATER HEATER MECHALVXCAL ROOFDRAINS -- FLOOR. DRAINS (- CITY OF LA QUINTA PLAN CHECK CORRECTION LIST Design Mind Studio 75-175 Merle Drive, Suite 200 Palm Desert, CA 92211 (760) 773-4488 PLAN CHECK NO. 07-3250 ADDRESS 53-034 Via Dona SCOPE OF WORK NSFR December 10, 2008 THIRD/FINAL CHECK (Structural) OCCUPANCY R -3/U-1 TYPE -OF -CONST. V -N The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Quynh Nguyen" V VCA CODE GROUP 2200 Orangewood Avenue, Suite 155 Orange, CA 92868 (714) 363-4700 1 VCA File No. LQ -20653.3A 'Coachella Valley Unified School District 83-733 Avenue 559 Thermab CA 2 4274 (760) 398-5909 — Fax (760) This Box For District Use Only DEVELOPER FEES PAID AREA: LEVEL ONE AMOUNT: DATE: LEVEL TWO AMOUNT: RECEIPT: AMOUNT MITIGATION AMOUNT: COMM/IND. AMOUNT: CHECK it: I INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: December 30, 2008 Project Name Gary &Diane. Lohman phone No. Owner's Name: Gary &Diane Lohman Project Address: 53-034 Via Dona LaQuinta, CA 92253 Project Description: SFD Lot #'s: 13D APN: 777-380-011-02 Type of Development: Tract #: Commercial Industrial Residential XX Total Square Feet of Building Area: 5,440 licant/Owners: The person signing certifies that the above information nis correct and makes this statement under Certification of App penalty of perjury and further represents that he/she is authorized to sign on y '=`� .. 12/30/08 Signature: ; Dated: **************** WILL BESATISFIED IN** SCHOOL DISTRICT'S REQ0REMTHE(C RCE NEPROJECT HAVE BEEN O ACCORDANCE WITH ONE OF THE FOLLOWING Not Subject to Fee Project Agreement Existing Requirement Education Code Gov. Code Approval Prior to 1/1/87 17620 65995 Note::; Number of Sq.Ft. 5,446 Amount per Sq.Ft. $3.78 Amount Collected $20,585.88 Building Permit Application Completed: Yes/No By: Y p Care M. Carlson, Asst. Supt., Support Services Certificate issued by: Laurie Howard, Secretary III Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES 'AND h'1 A' �lvl�l,er►od to protest the imposition of these Section 66020 of the Government Code asserted by Assembly Bill 30 y effective January 1, 1997, requires that this District provide (1) a written notice to the is Notice shall serve V project appellant, at the time of payment of school fees, mitigation payment or other eofe Government commences with the payment of the fees or performance of any othe 2 the amount of the fees. Therefore, in accordance with the validity thereof, the Government code and payothement s of thehereif et forth, applicable law, whether payable at the Fees and () protest period in regard to such Feeshe fees imposed is advise you that the criday p P ount Of t eof, requirements as described in section 66020 of the Government code. occupancy. As ,bee ra ted only for good cause, as determined by the School District, and u in whole or in part prior to issuance of a Certif►caf Extension As g the latter, the 90 days starts on issued for the project heat is thelsubjel time or days from the date of issuance.ot Compliance is valid for thirty (30) y to three (3) such extensions may be granted. At such time as this Certificate expires, if a buildingcae permit has ce 'nate the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance less 3% for administration fees to process tt of this Certificate, 3/9/07 reimbursement. MV:c/mydocs/devfces/certificate of compliance form updated 3-2007 gf CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE- OF BUILDING PERMIT OM Form updated & effective 612612008 Green Sheet approvals are forwarded to the Building & Safe1y Department directly by Public. Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: - "o Developer: e0 �$ Tract No.: Tract Name: Lot No.(s) _ Address(s): . ® Phone Number:l�0• The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the (wilding & Safety Department- 4 CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 AND #5 BELOW ti• TRACT HOMES: PROVIDE ITEMS #1 #2 #3 #4 (AS APPLICABLE) AND #6 BEL01 ECEVED 44 COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 AND #5 BELOW �o WALLS: PROVIDE ITEMS #7 BELOW DEC •9 SIGNS: PROVIDE ITEMS #8 BELOW 0OTHER: PROVIDE ���Ic ' ITEM #9 BELOW VGjlOpine— f 1. Attach Pad Elevation Certificates in compliance with. the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). if a.precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. i 2.. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. o4 f 11~f 6D A-Vf 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. t� Final maps may be viewed at the following website: 60 f W ea d-1411 ! htto://www.la-guinia.orgiPlanCheck/m search aspx 4. Attach a completed <1 acre per lot or infill project Fugitive Dust Control project information form, PM 10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the precise grading plan to the Public Works Department showing building location(s). AO flood zone developments will require an approved flood plain development plan. 6. Attach an approved rough or precise grading plan for the building location(s) for pad elevation verification or City plan set number if available. Plans may be viewed at the following website: http://www.la-auinta.org/PlanChock/m search.asox 7. Attach wall plan & related approved grading plan. 8. Attach sign layout/plan & related precise grading/landscape plan. 9. Attach supporting documentation for grease trap or special facility installations. have reviewed and confirmed the requiren3ents listed above as presented and find the improvements to be l sufficiently complete for construction of a proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my fi the a ojec ay be released for building permit issuance. Recommended by: Dated: Public Works Distribution: ( LGreen Sheet to Building & Safety (�) Green Sheet to Planning Department V Declined for approval for reason(s) as follow(s), please correct and resubmit: Page 1 of 4 ! i City of La Quinta, California PM 10 Fugitive Dust Control Project information I< 1 acre/lot or Infill Project) (Form Updated & Effective 6-26-08) Project Information Project Contractor: Project Phase (check one) Construction 0 Demolition Project Name: 1. ve- Project Tract Number: q�Q Lot Numbers: Project Street Address: tl,10" Anticipated Start Date: �.® Anticipated Completion Date: - -_(o Total Acres in Active Construction (< 1 acre per Lot): • �� Project Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: t9A,41tV Title: C Company Name: Malling Address: ro. ML4 542Q City: State: 46. Zip Code: 0 Primary Phone #: 1 W • Fax #: r 24 Hour Access/Emergency ' bone#: 0. 1b 3�Lb•32� Cell Phone #• 160-!Z50- 4401 Email address: t7Mt. , CD PM10 Certificate #: C6.41. 1244 ' � VTa. Expanded PM 10 plans for commerc al and residential developments > 1 acre are required by the City of La Quinta. Page 2of4 Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill Project) Plan Updated 6-26-08 This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ . Visible dust emissions >20% opacity ■ Visible dust emissions that travel > 100 feet from the source (within site) Visible dust emissions that cross any property line ❖ EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM 10 class and obtain PM 10 certificate number prior to construction activity (training information may be obtained by contacting SCAQMD at (909) 396-2183). •S CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Control Plan must be kept on site. At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. 4:• WEATHER MONITORING: Wind predictions shall be monitored. •S SIGNAGE: Approved signs shall. be installed at a highly visible location. Please refer to the Coachella Valley Fugitive bust Control Plan Handbook for Construction Signage Guidelines. •S TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 1 6vmph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. * PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. + TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public- or private roads. Track out shall be cleaned up within one (1) hour of incident and at the conclusion of each workday. ❖ DIRT FILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM 10 fencing during the construction phase. EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be applied during excavation or grading operations. Page 3 of 4 4 f ......_.._.._.._........ .._..........---....._........._._.._.._�..._ . ... . - - --- - . Fugitive Dust Control PM10 Plan (< 1 acre per Lot or Infill Project) Plan Updated 6-26-08 DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. ' ❖ RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records of use of chemical suppressants, -etc.) shall be maintained for 3 years by the Property. Owner (or Authorized Representative). Property Owner shall notify the City and SCAQMD within 10 days of completion of project. City of La Quinta — Site Specific Construction Phase PM10 Agreement Agreement Updated 6-26-08 The signature of the property owner (or authorized representative): 4- Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. The property owner (or authorized representative): •S Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; •: Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; 4• Shall take all necessary precautions to minimize dust, even_ if additional measures beyond those listed in the dust control plan are necessary; �.� Shall authorize representatives of City/County to enter upon the property for inspection and/or abatement purposes; and ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature of Property Owner or Authorized Representative Date Printed Name of Property Owner or Authorized Representative Title of Property Owner or Representative -now Company Name i i i Phone Number Page 3 of 4 November 6, 2008 Gary Lohman Lohman, Gary c/o Andrew Pierce Corporation Palm Desert, CA 92261 Regarding: 13323 Lohman Residence Subject: Structural Truss Shop Drawing Review Dear Mr. Lohman, Accompanying this letter, we are returning (4) sets of shop drawings bearing the same imprint as at the base of this letter. The drawings were reviewed for general conformance with design concept of the project as indicated by the structural documents prepared by our office. We have not reviewed quantities or dimensions. We have not reviewed fabrication processes, techniques of construction, or coordination of the work with that of any other trade. We have not reviewed the manner in which the work would be performed or if it may be performed in a safe and satisfactory manner. Should we have made any comments or corrections on the drawings, these comments or corrections do not relieve the contractor from compliance with the structural documents. In as much as we have reviewed the drawings only for general conformance with the design concept, unless deviations from the design intent have been clearly indicated as such, we may not have made note of them and the contractor is not relieved from compliance with the structural documents. Our review of these drawings is not an indication of their preparation under our supervision. These shop drawings are being returned with no objection taken to their use. If you have any questions, please contact our office. Very truly yours, BORM ASSOCIATES, INC. 7<5ca� �v Brandon Winter Project Engineer BW: 1/13323 110608 Truss Review Distribution: (4) Jim Deford via overnight (1) Jeff @ Trussworks via fax (1) File 13323 Encl.: (4) "Roof Truss Shop Drawings," dated 11/04/2008 "n nC� Fj e Structural Shop Drauvmgs Beier io letter hearing this imprint for infiorniation r cf - F°r:`x low