Loading...
04-6119 (SFD)R14 200 1� �avr. BUILDING &c SAFETY DEPARTMENT w4 P.O. Box 1504 ° (760).777-7012 'F 9 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number -04-00006119 Date 11/30/04 Property Address -53072 VIA DONA APN: 772-410-999,-14 .• -298944 - Tenant nb•r, name HIDEAWAY Application description ...DWELLING - SINGLE FAMILY DETACHED_ Property Zoning LOW DENSITY RESIDENTIAL ' Application valuation . . 361763 Owner Contractor HIDEAWAY JOINT VENTURE II ALPHA OMEGA COMMUNICATIONS INC 42829_ COOK ST STE'104 <42829 COOK STREET. PALM'DESERT CA ,92211 PALM.DESERT CA 92260 (76 0) 568-1712 WCC:" STATE FUND WC: 164166403 06%30/05 CSLB: 820066 05•/31/05 CCC: B -------------------------- Structure Information ----------------- ------- .Construction Type TYPR V - NON -RATED Occupancy.Type . . DWELLG/LODGING/LONG <=10 Flood Zone . . . NON -AO FLOOD.ZONE Other struct info .'. CODE EDITION 2001 :# BEDROOMS 1.00 FIRE SPRINKLERS NO GARAGE SQ FTG 925.00 PATIO SQ FTG 625.00 NUMBER.OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4150.00 Permit BUILDING PERMIT Additional desc .Permit.Fee 1556.50 Plan Check Fee .1011.73 Issue Date Valuation . . . . 361763 Qty Unit Charge Per Extension BASE FEE 639.50 262.00 3.5000 THOU BLDG 100,001-500,000 917.00 Permit-. ELEC-:-NEW RESIDENTIAL :Additional de'sc Permit.Fee 191.25 Plan.Check Fee 47•.81 Issue Date Valuation 0 Qty Unit Charge Per 'Extension BASE FEE - 15,00 4150.00 .0350 ELEC NEW RES' - 1 OR '2 "'FAMILY 14-5.'25 1550.'00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 31.00 P.O. BOC 1504 Tiff 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: Ut - 6 // q Applicant: _ C-FRQN� G DF, Applicant's Mailing Address: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777.7153 Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of p��¢¢fury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and ss Lice a �(y odc�land effect. D, �J —7 7 License Class � �,�W� UUU��tllt � License No. ( 4�35 // Date U Contractor co OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to.its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain w ,rkers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is e My, rkers' fnpensation insrance carrier and�p Ic y. numbeli 2 Carrier PolicyNumber , (LTJ f/ (b/�EJI certif t, in the performance of the work for which this permit is ssued,,shal not toy any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith mpty with those provisions. Date ! Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and herebyieuthodze representatives of this county t enter upon the above-mentioned property for inspection purposes. Date Signature (Applicant or Agent): rr0{gL''r'?gu 90, Page 2 Application Number 04-00006119 Date. 11/30/04 Permit . . . . GRADING PERMIT Additional desc Permit Fee . . . 15.00. Plan Check Fee.. .00 Issue.Date Valuation 0 Qty Unit Chargee Per _ Extension BASE FEE 15.'00 ----------------------------------------------------------------------------- Permit . . . . MECHANICAL. - Additional desc Permit Fee . . . 147.00. Plan Check'Fee 36.75 Issue Date . . . Valuation 0 Qty Unit Charge- Per, Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU. 27.00 5:00 6.5000 EA MECH.VENT FAN 32.50 6.00 6.5000 EA MECH OTHER VENT.SYSTEM 39.00 1.00 6.5000 EA MECH EXHAUST.HOOD' 6.5.0 Permit PLUMBING Additional descl.- Permit Fee 20.5.50 Plan Check Fee-'. 51.38 Issue Date Valuation . . . . 0 Qty -Unit Charge Per. Extension BASE FEE 15.00 20.00 6.0000 EA` PLB FIXTURE 120.00 .1.00 15.0x0& EA PLB BUILDING SEWER 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 2.00 7.5000.EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 -EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 7500' EA PLB GAS PIPE >=5 7.50' 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments SFD - 4,150 SQ.FT. LIVING, 925 SQ.FT. GARAGE, 625 'SQ.FT. PATIO. R-3/U-1.<OCC. TYPE V -N CONSTR. 2001 CODES. Other Fees ART IN PUBLIC PLACES -RES 404.40 DIF COMMUNITY CENTERS -RES 97.00 ..DIF.CIVIC CENTER - RES '366.00 Page 3 Application Number . . . . . 04-00006119 Date, 11/30/04 ---------------------------------------------------------------------------- Other.Fees . . . . ... . ENERGY REVIEW FEE 101.17 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 - DIF PARK MAINT FAC - RES 5.00 DIF-PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 36.17 - DIF STREET MAINT FAC -RES. 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited_ Due Permit Fee Total 2115.25 00 00 2115.25 Plan Check'Total 1147.67 500.00 .00 647.67 Other Fee Total 2946.74 00 .00 2946.74 Grand Total 6209.66.. 500.00 .00 5709.66 r 53 -o7c';- Building V 1� Address Owner �O ailing ddvress !� ikart I Zip o?i, State Lic. J& Classif. Arch., Engr., �� Designer 4 T4tyl 'IN uu� 04- 411f P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO QLA QUINTA, CALIFORNIA 92253 BUILDING: TYPE'CONST. OCC. GRP. J2--� & i c A.P. Numbel" �J Lic. # cJ�e is l-7/2, 77 I Lict# LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's -License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I- I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) 1] I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 7 1 am exempt under Sec. B. 6 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company r7 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work. for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant —Date— Mailing ateMailing Address City, State, Zip Description V Sq. iz Ft./ '' F� Stories No. s J Size (� ! �C Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ h Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. JTWI IOU Plan Chk. Bal: Const. Mech. Electrical f U/r Plumbing /rf �-- J/I S.M.I. )II ILI i SSP r' - 11111 Grading 004 UP Driveway Enc. Infrastructure FlWgjy UINTA TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE, RF.CF.TPT- f.HF.r.K N- rNITIAIS• CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Resideace at the'=Htdeaway Date: December 13, 2004 Owner's Name: Hideaway Joint Venture II Phone No. Project Address: 53-072 Via Dona La Quinta, CA Project Description: 1 SFD APN: 772-410-004-3 Tract #: Lot #'s: Type of Development: , Residential XX Commercial Industrial Total Square Feet of Building Area: 4,150 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: December 13, 2004 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code . , Project 17620 65995 Approval Note: Number of Sq.Ft. 4,150 Amount per Sq.Ft. $ 2.68 Amount Collected $ 11,122.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Agreement Existing Prior to 1/1/87 Certificate issued by: Elvira Mattson, Office Technician Signature Not Subject to Fee Requirement NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. Li�':c;m}dve %cies lei ieerti(icate orcompliance. ti?rm Wile 170 LTSF.doc 1/16/03 T Jun 11 04 02:45p Butch Seal. R»1-1-1 TV r%!A11ONAL TITLE COMPANY 303-794-4437 p.l at -MOM 1SION BEFARTMENT DOC tot 2004-0204515 03/24/2004 08:00A Fee:16.00 WHEN RECORDED MAIL TO: Page 1" of 4 Doc T Tax Paid Recorded in Official Records Seal Office Supply, Inca County of Riverside 2092 W. Nantucket Ct. Gary L. Orso Littleton, CO 80120 Assessor, County Clerk $ Recorder I f IIIA lNIII (IIIIi IIII III! 1111 IIIiNlI III VIII Illi I(II MAIL TAX TA(�X STATEMENT TO: SAME AS ABOVE L - M S U VALE _SRE DA PCOR f NOCOR SVF MSC A R � COPY LONG REFUND NCMG E7q,� DOCUMENT TRANSFER TAX $ 445.50 C� XX Computed on the consideration or value of property conveyed, OR � Computed on the consideration or value less liens or encumbrances MA remaining at the time of sale. Signature of Declarant or Agent determining tax - Firm Name GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANTS) to Seal Office Supply, Inc., a California Corporation ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: 1 ��b ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty. Investors, Ltd. an Ohio limited liability compa y its managing ber 174 By: Joseph L. Arenson Authorized Representative r - Jun 11 04 02:45p Butch Seal 3037794-4437 p.2 STATE OF California COUNTY OF Riverside On March 8, 2004 before me, K. Larbv, Notary Public (Name, Title of Officer) personally appeared_ Joseph L. Arenson personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose'name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the. person(s), or, the entity upon behalf of -which the person(s) acted, executed the instrument. WITNESS my hand and official seal. OFFICIAL SEAL K. LnRBY COMM #1268797 (Signa use of otar Pub c) Notary Public.. California p RIVERSIDE COUNTY My Commission Expires JUNE 24, 2004 (This area for notarial seal). .Jun 11 .04 02:45p T Butch Seal 303-794-4437 p.3 Parcel No. 1: (the "Lot") of Tract No. 29894-4, in the City of La Quirita, as shown by Map on file in B 51, Pages 49 to 57, inclusive, of Maps, in the Office of the County Recorder of Riverside County, California. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, -and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights. for access, ingress, -egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the.following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, -the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 74593.8, of Official Records of Riverside County, California (the "Official Records"); 2. The Supplementary Declaration of Annexation of Property, recorded on March 4, 2004, as Instrument No: 2004-0151981; of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this. Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: L Non delinquent general, special and supplemental'real property taxes and assessments. 1 ,Jun 11 04 02:45p Butch Seal` 303-794-4437 p.4 2. All other covenants, conditions; restrictions, reservations,. easements,rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-4. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed; (b) grants to Grantor. and The'Bideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving, disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association such powers.and rights which are set forth in the Declaration defined above, on 3 , 2004. , SEAL OFFICE SUPPLY, INC. By: Jo Seal , Its: Authorized Representative STATE OF!�- ss. COUNTY OF On Ai. -e -LL /7 2004, before me, the'undersigned, a notary public in and for said State, personally appeared Jon Seal, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument, and acknowledged to me that they executed the same in their authorized capacities, and.that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. ` • CONNIE CONCMO [SEAL] y COMM, # 1417229 Signature C NOTARY PUBLIC -CALIFORNIA RNERSIDE COUNN — MY COT=hSbn E7ghes May 11.2007 . My commission expires: ".� LOIJ -� --Oertifica to of Occupancy LICOR OF9w. Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-072 VIA DONA Use classification- SINGLE FAMILY DWELLING Building Permit No.: 04-6119 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: HIDEAWAY JOINT VENTURE II Address: 42-829 COOK ST STE. 104 City, ST, ZIP: PALM DESERT, CA 92211 -�� By: STEVE R. WILLETT Date: MARCH 10, 2006 Building Official POST IN A CONSPICUOUS PLACE ip) �� TITLE 24 REPORT Title 24 Report for: Lot #14D - The Hideaway. Via Dona La Quinta, CA 92253 Project Designer: Gordon Ross 42-829 Cook St, Suite #204 Palm Desert, CA 9221.1 (760) 568-1712 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING " 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Date: 19,/27/2004 f The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User pg .19 SS*072 UR 0%A 16*ncr /cop 41 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary. 8 .HVAC System Heating and Cooling Loads Summary 13 Room Load Summary 16 Room Heating Peak Loads 19 Room Cooling Peak Loads 22 HVAC Equipment Specifications. 26 } EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 'Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #14D - The Hideaway Fenestration 10/27/2004 Project Title Date Via Dona La Quinta t Location/Comments Project Address Type Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone 0.059 Computer Performance 1 15 Field check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION R-38 Roof (R.38.2x14.16) Wood Total Conditioned Floor Area: 4,150 ft2 Average Ceiling Height: 10.6 ft Total Conditioned Slab Area: 4,150f? 0.756 Building Type: ❑ X❑ (check one or more) Rear (East) X❑ Single Family Detached ❑ Addition 0.38 ❑ Single Family Attached ❑ Existing Building ❑ ❑ Multi -Family ❑ Existing Plus Addition Rear Front Orientation: (West).270 deg ` Floor Construction' Type: FX] Slab Floor Number of Dwelling Units: 1.00 Screen❑ Number of Stories: 1 - ❑ Raised Floor BUILDING SHELL INSULATION Orientation Area Fenestration Exterior Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-38 Roof (R.38.2x14.16) Wood 0.026 Exterior Roof Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation ❑ X❑ ❑ X❑ Rear FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins • SF U -Factor SHGC Shading Yes / No Yes / No Left (North) 36.0 • 0.38 0.30 Bug.Screen ❑ X❑ ❑ x❑ Left (North) 56.6 0.35 0.38 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 110.4 0.35 0.38 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 72.0 0.39 0.28 Bug Screen❑ X❑ ❑ x❑ Right (South) 48.0 0.39 0.28 Bug Screen ❑ x❑ ❑ x❑ Right (South) 61.8 0.35 0.38 Bug Screen ❑ X❑ ❑ RI Front (West) 38.0 0.35 0.38 Bug Screen ❑ X❑ ❑ x❑ Rear .(East) 240.0 0.37 0.30 Bug Screen x❑ ❑ ❑ X❑ Front (West) 173.0 0.39 0.28 Bug Screen • ❑ 0 ❑ X❑ Left (North) 24.0 0.39 0.28 Bug Screen • ❑ X❑ ❑ X❑ Left (North) 64.0 0.37 0.30 Bug ScreenX❑ ❑ ❑ x❑ ❑ ❑ ❑ ❑ Run Initiation Time: 10/27/04 13:58:08 Run Code: 1098910688 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number:. Page: 3 of 35 `Certificate of Compliance: Residential (Part 2 of 2) CF -1 R ' Lot #14D - The Hideaway 10/27/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments r=Pntral Fiirnar - —80% AFUE Ducts in Attic 42 Setback HVAC -1 rentmi Fnrance 80% AFUE Ducts_ in Attic 42 Sethack HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback - HVAC -3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Sethnrk HVAC -1 Split Air Conditioner 14 0 SEER Durts in Attic 4.2 R -thank HVAC -2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 . Setback HVAC -3 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O Smith FSG -75-230 Small Gas R - it -/Tim +T .mo 75.000 74 0.48 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (gated input of greater than 75,000 Btu/hr), list Rated Input, Recovery. Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT I ` This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the ' California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. ' Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ Mcfadden Title/Firm: Gordon Ross Title/Firm: BREEZE AIR CONDITIONING Address: 42-829 Cook St, Suite #204 Address: 75-145 ST. CHARLES PLACE ` Palm Desert, CA 92211 PALM DESERT, CA 92211 Telephone: (760) 568-1712 Telephone: (760) 346-0855 Lic. #: (signature) (date) Enforcem Name: f Title/Firm: ' Address: Telephone: 10 a7 (signature) (date) natu lEnemvPro 3.1 By EnergvSoft User Number. 3665 1 1 Job Number. , Page:4 of 35 1 Certificate of Compliance: Residential (Addendum) CF -1 R Lot #14D - The Hideaway 10/27/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adequacy of the justification, and may reject a building or design that otherwise complies used on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC Svstem "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification y These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. EneravPro 3.1 By EneravSoft User Number. 3665 Job Number. Page:5 of 35 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1R NOTE: LOWrlse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(.): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. * 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X§ not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no Elgreater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and. infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaceshave: a. Closeable metal or glass door ' b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space. Conditioning, Water Heating and Plumbing System Measures ❑X § 110-13: HVAC equipment, water heaters; showerheads and faucets certified by the Commission. a§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external t insulation or R-16 combined intemal/extemal insulation. i 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:6 of 35 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (')'may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603; 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions In the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g.; protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material: § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. , X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. Iry 1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. r 3.1 By EnergySoft User Number. 3665 Job Number. Page:7 of 35 11 Computer Method Summary (Part 1 of 3) C -2R _Lot #14n - The Hid.ea_way ■: G•- 10127/2004 Project Title -/_ia-Dm.a—Lc_()-ui llta MA RTATF�1 Date Project Address Building Permit # AIEZCONDITl ING ■M (760) 346-0855 -BREEZE Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) �. Climate Zone ■ Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin ►1 Space Heating 3.96 3.95 0.00 ■ Space Cooling 35.27 30.04 5.24 Domestic Hot Water 6.87 9.98 -3.11 ■ Totals 46.10 43.96 2.13 Percent better than Standard: 4.6% Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 4,150 ft2 Floor Construction Type: ❑ Raised FloorX❑ Slab Floor Single Fam Detached (West) 270 deg Total Fenestration Area: 22.3% 1.00 Total Conditioned Volume: 43,946 ft 3 1 Total Conditioned Slab Area: 4,150 ft 2 # of Floor Area Volume Units Zone Type 1 665, 1 261 1,224 Solar. OPAQUE SURFACES Act. . Gains Type Area U -Fac. Azm. Tilt Y / N RGO — 0 0-026 0_� Wall 166 0.059_ _go 90 Wall 477 0.059 180 90 wall 282 0.059 270 90 Roof_ 1,261 0.026 n n Wall— 72 0.05 _0 90_ -Wall— 201 0.059 270 q.Q Roof— 1.224 0.026 _0 _ 0 Wall_ 239 0.059 _0 _ 90 Vale 303 0.059 g0_ _990 Wall— 569 0.059 180 90 -Wall _ 352 0 059 270 _990 17 316 0_40 Sleeping_ 14.880 0.3.Q_ Living 11750 _0.29_ Living Form 3 Reference wl �i ■: G•- ,/ ■M MA RTATF�1 (11 ■M Z&A ITY0 I ffiviv&.4 '1 ■M Z&A Rug I ff1 / ■RTATJNESM1. �. 1/ ■ � u ,1 ■C.� ►1 ■= zapa RVATi9iu ►1 ■M MA WIT-1 �/ ■ L/ ■KTATJ ■ ■ ■ ■ 7nne-1 Zonp-1 Zone -2 7nn -2 Zone -'1 Zone_3 Thermostat Vent Type Hgt. Area Sleeping4tnt _2 n/a _ . .._. LivingStat— _ 2 n/a — LivingStat— —n/ Location / Comments EnemvPro 3.1 By EnemvSoft User Number. 3665 Job Number: Page:8 of 35 1 Computer Method Summary (Part 2 of 3) C -2R Lot #14D - The Hideaway 10/27/2004 Project Title Date FENESTRATION SURFACES ' U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J_ Wiadow__Left (NoJih) _36_0- 0-.8Q 0.30 p 9Q Sierra Pa Clad_(Lo/E) Zone -1 2 Window Left (North) 10.0 0.350 0.38 0 90 Sierra Pacific Clad (Lo/E) Zone -1 ' 3 Window Left (North) 10.0 0.350 0.38 0 90 Sierra Pacific Clad (Lo/E) Zone -1 4 Window Left (North) 6.3 0.350 0.38 0 90 Sierra Pacific Clad (Lo/E) Zone -1 5 Window Left (North) 6.3 0.350 0.38 0 90 Sierra Pacific Clad (Lo/E) Zone -1 6 Window Rear (East) 24.0 0.350 0.38 90 90 Sierra Pacific Clad (Lo/E) Zone -1 7 Window Rear (EastL 48.0 0,390 0.28 90 90 Sierra Pacific Clad (Lo/E) Zone -1 8 Window Rear (East) 24.0 0.350 0.38 90 90 Sierra Pacific Clad (Lo/E) Zone -1 9_ W ndQw Rear (East) 24.0 0,390 0.28 90 90 Sierra Pacific Clad (Lo/) Zone -1 10. Window Rear (East)_ 24.0 0,350 0 38 90 90 Sierra Pacific Clad (Lo/E) Zone -1 ' 11 Window Right (South) 24.0 0.390 0.28 180 90 Sierra Pacific Clad (Lo/E) Zone -1 12 Window Right (South) 24.0 0.350 0.38 180 90 Sierra Pacific Clad (Lo/E) Zone -1 -i WiadoYL_E_ront (West) 30.0 _0,350 __0_M -270 -9Q Sierra Pacjf_Clad (Low) 7one-1 14 Window Front (West) 8.0 0.350 0.38 270 90 Sierra Pacific Clad (Lo/E) Zone -1 ' 15 Window Rear (East) 240.0 0.370 0.30 90 90 Sierra Pacific Clad (Lo/E) Zone -2 16 Window Right (South) 12.5 0.350 0.38 180 90 Sierra Pacific Clad (Lo/E) Zone -2 17 Window Front (West) 48.0 0.390 0.28 270 90 Sierra Pacific Clad (Lo/E) Zone -2 18 Window Front (West) 57.0 0.390 0.28 270 90 Sierra Pacific Clad (Lo/E) Zone -2 ' 19 Window Front (West) 48.0 0.390 0.28 270 90 Sierra Pacific Clad (Lo/E) Zone -2 20 Window Left (North) 24.0 0.390 0.28 0 90 Sierra Pacific Clad (Lo/E) Zone -3 21 Window Left (North) 24.0 0.350 0.38 0 90 Sierra Pacific Clad (Lo/E) Zone -3 22 Window Left (North) 64.0 0.370 0.30 0 90 Sierra Pacific Clad (Lo/E) Zone -3 23 Window Rear (East) 23.4 0.350 0.38 90 90 Sierra Pacific Clad (Lo/E) Zone -3 ' 24 Window Rear (East) 15.0 0.350 0.38 90 90 Sierra Pacific Clad (Lo/E) Zone -3 25 Window Right (South) 24.0 0.390 0.28 180 90 Sierra Pacific Clad (Lo/E) Zone -3 26 Window Right (South) 3.0 0.350 0.38 180 90 Sierra Pacific Clad (Lo/E) Zone -3 27 Window Right (South) 3.0 0.350 0.38 180 90 Sierra Pacific Clad (Lo/E) Zone -3 ' 28 Window Right (South) 19.3 0.350 0.38 180 90 Sierra Pacific Clad (Lo/E) Zone -3 29 Window Front (West) 20.0 0.390 0.28 270 90 Sierra Pacific Clad (Lo/E) Zone -3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # • Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 5 Bug Screen 0.76 - 6 Bug Screen 0.76 7 Buq Screen 0.76 8 Bug Screen 0.76 ' 9 Bug Screen 0.76 _ 10 Bug Screen 0.76 11 Bug Screen 0.76 _ 12 Bug Screen 0.76 ' 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 10.0 24.0 10.0 0.1 10.0 10.0 16 Bug Screen 0.76 " ' 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 ' 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 8.0 8.0 0.1 8.0 8.0 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 ' 26 Buq Screen 0.76 27 Bug Screen 0.76 28 Bug_ Screen 0.76 _ 29 Bug Screen 0.76 ! Run Initiation Time: 10/27/04 13.58:08 Run Code: 1098910688 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:9 of 35 Comouter Method Summary (Part 3 of 3) C -2R Lot #14D - The Hideaway 10/27/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES HVAC SYSTEMS Heating Equipment F2 Insulation Energy FacO Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 17 0_76 0.0 0 Zone -1 Slab P_eiimeter ---15,q 0.76 -D Q 0 R -Value Slab Perimeter 8 0.76 0.0 0 Zone -2 Blab-Eerimeter 75 0_76 --U —Q Zone -2 _Slab Perimeter 17 0_76 0.0 0 Zone -3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Energy FacO 1 Tank Insul. Type (air conditioner, Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Energy FacO 1 Tank Insul. Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -3 'WATER HEATING SYSTEMS _ Ratedl Tank Energy FacO 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.0 -Smith FSG -75-230 Small Gas Recirc/Time+Temp. —2— 75,000 74 0.48 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list.energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Comauter Method Summary (Part.3 of 3) C -2R Lot #14D - The Hideaway 10/27/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location. - Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 160 0.76 0.0 0 Zone -3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location,- Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc:) R -Value Type Comments Hydronic Piping Pipe Pipe Insula System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat ' Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments. WATER HEATING _SYSTEMS t Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS - Computer Method Summary (Addendum) C -2R tLot #14D - The Hideaway 10/27/2004 Project Title Date ' Special Features and Modeling Assumptions , The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local onf—m—t nnonry rlotorminoe tho adonnary of tho hmtifirntinnand may rP_iert a huildina or desian that otherwise comolies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System"HVAC-2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. I Plan I Field The HVAC System "HVAC -1" includes Refrigerant Charge and: Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. , r 1 7 Run Initiation Time: 10/27/04 13:58:08 Run Code: 1098910688 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:12 of 35 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #14D - The Hideaway 10/27/2004 SYSTEM NAME FLOOR AREA HVAC -1 1,665 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 31,222 -833 33,498 HS26-060/G40UH60C-110 (5) 45,578 2,253 89,400 Total Adjusted System Output 45,578 2,253 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.3 of 105.0 of 105.0 of Supply Air Ducts Outside Air:' 0 cfm Heating Coil Supply Fan 104.3 �F 2000 cfm ROOMS 70.0 of 69.3 of �% Return Air Ducts 4 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0 / 73.5 of 74.7 / 60.8 of 55.0 / 53.5 of 55.0 / 53.5 of , Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 55.7 / 53.8 of 2000 cfm 46.0% R.H. ROOMS 74.7/60.8 of 74.0/60.5OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY iPROJECT NAME Lot #14D - The Hideawa SYSTEM NAME HVAC -2 EATING SYSTEM PSYCHROMETRICS A ' 26.0 of 69.4 of Outside Air 0 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 10/27/2004 FLOOR AREA 1,261 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,363 27,569 -715 674 25,122 0 104.4 of Supply Fan 1,378 1,256 0. 0 0 0 01 0 0 0 0 1,378 1,256 30,326 -715 27 634 HVAC EQUIPMENT SELECTION HS26-060/G40UH60C-110 (5) 45,475 2,380 89,400 Total Adjusted System Output 45,475 2,380 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am yam Tei 105.0 of ' Heating Coil 69.4 of 'COOLING SYSTEM PSYCHROMETRICS (� 115.0 / 73.5 of ' Outside Air 0 cfm 74.6/60.80F EnergyPro 3.1 By EnergySoft User Number. 3665 res at Time of Heating Peak) 105.0 of °�, Supply Air Ducts „ Vie, 104.4 of Supply Fan 2000 cfm ROOMS 70.0 of �% Return Air Ducts `S 74.6/60.80F = 55.0/53.50F Cooling Coil r Supply Fa 2000 cfm 55.0 / 53.5 of -�j Supply Air Ducts Fan 55.6 / 53.8 of 46.1% R.H. ROOMS 74.0 / 60.6 of K Return Air Ducts Y Job Number: 14 of 35 ' EATING S, ' 26.0 OF Outs— -A ide Air 0 cfm 69.2 OF ' OOLING S 115.0 / 73.5 OF ' Ou— de A 0 cfm ' 74.6/60.8 ° F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Lot #14D - The Hideaway DATE 10/27/2004 SYSTEM NAME FLOOR AREA HVAC -3 1,224 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,039 20,999 -565 693 25,804 0 1,050 1,290 0 0 0 0 01 0 0 0 0 1,050 1,290 23,099 -565 28 385 JVAC EQUIPMENT SELECTION HS26-048/G40UH488-090X (4) 37,489 1,772 72,100 Total Adjusted System Output37,489 1,772 72,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tei 69.20F M 105.0°F Heating Coil res at Time of Heating Peak) 105.0 OF Uwn"-'i Supply.Air Supply Fan 104.2 OF 1600 cfm ROOMS 70.0 OF k Return Air Ducts `S 74.6 / 60.8 OF M 55.0 / 53.5 OF 55.0 / 53.5 OF EnergyPro 3.1 By EnergySoft User Number. 3665 Cooling Coil I Supply Air Ducts Supply Fan - 55.6 / 53.8 OF 1600 cfm 46.2% R.H. ROOMS 74.0/60.6°F Return Air Ducts Job Number: Page: 15 of 35 i ROOM LOAD SUMMARY � PROJECT NAME Lot #14D - The DATE 10/27/2004 -Hideaway SYSTEM NAME HVAC -1 FLOOR AREA 1,665 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone -1 Master & Guest Suites 1 1,404 28,384 -833 1,404 28,384 ' -833 818 30,453 r PAGE TOTAL 1 1,404 28,384 -833 818 30,453 TOTAL 1 1,404 28,384 -833 818 30,453 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 16 of 35 ROOM LOAD SUMMARY ::1 PROJECT NAME Lot #14D - The Hideaway DATE .10/27/2004 SYSTEM NAME HVAC -2 FLOOR AREA 1,261 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone -2 Great Rm/Dining/Entry/Hall 1 1,363. 27,569 -715 1,363 27,569 -715 674 25,122 r i PAGE TOTAL 1 1,363 27,569 -715 674 25,122 TOTAL 1 1,363 27,569T7 -715F 674 25,122 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 17 of 35 ROOM LOAD SUMMARY PROJECT NAME Lot #14D - The Hideaway DATE 10/27/2004 SYSTEM NAME HVAC -3 FLOOR AREA 1,224 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone -3 Kitchen/Guest Office/Laundry 1 1,039 20,999 -565 , 1,039 20,999 -565 693 25,804 PAGE TOTAL 1 1,039 20,999 -565 693 25,804 TOTAL 1 1,039 20,999 -565 693 25,804 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 18 of 35 ROOM HEATING PEAK LOADS Project Title Date Lot #14D - The Hideaway 10/27/2004 Room Information Design Conditions Room Name Master & Guest Suites Time of Peak Jan 12 am Floor Area 1,665 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature .70°F Conduction Area U -Value LT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 939 Infiltration: 1 1.001 x 1.064 X 1 665 X 10.40 x 1.00 / 60] X 44 = 13 514 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 30,453 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 19 of 35 1647.4 X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0592 X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 36.0 0.3800 44.0 166.6 0.3500 44.0 96.0 0.3900 44.0 perimeter = 176.0 44.5 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 939 Infiltration: 1 1.001 x 1.064 X 1 665 X 10.40 x 1.00 / 60] X 44 = 13 514 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 30,453 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 19 of 35 ROOM HEATING PEAK LOADS Project Title Date Lot #14D - The Hideaway 110/27/2004 Room Information Design Conditions Room Name Great Ra/Dining/Entry/Hall Time of Peak Jan 12 am Floor Area 1,261 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction 1 Area X X X x� x x X X X X X X X X X X X X X x X X X X X X X X X X X X X X X X X X X U -Value x X X x X x X X x X x X X X x X X X X X X X X X x X X X X x x X X x X x X x X Z�T°F = = = = = = = = = = = = = = Btu/hr 1261.0 0.0258 44.0 1,430 637.5 0.0592 44.0 1,661 240.0 0.3700 44.0 3,907 12.5 0.3500 44.0 192 153.0 0.3900 44.0 2.6 25 perimeter = 83.0 44.5 3,694 .Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 13 510 r Infiltration: 1.00 x 1.064 x x 11.80 x 1.00 /'60] x 0 = 11 613 chedule Air Sensible Area i Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 25,122 j EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 20 of 35 ROOM HEATING PEAK LOADS Project Title Date Lot #14D - The Hideaway 10/27/2004 Room Information Design Conditions Room Name Kitchen/Guest Office/Laundry Time of Peak Jan 12 am Floor Area 1,224 Outdoor Dry Bulb Temperature 260F ' Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 634 Infiltration: r 1.00 x 1.osa x 1 22a x s.so x 1.00 / 60] x 0 s 170 `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 25,804 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:21 of 35 f. 1224.0 x x X x x x x x x X x X X x X x x x X X x X x X X X X x X x x x X X x x X X x 0.0258 X x X x x X X x X x x x X X X X X X X X X X X X x X x X. X X X x X X X X x X X 44.0 = = = = = = = = = = _ = 1,388 1,462.3 0.0592 44.0 3,810 68.0 0.3900 44.0 1,167 87.7 0.3500 44.0 1,351 64.0 0.3700 44.0 1.042 perimeter = 177.0 44.5 7,876 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 634 Infiltration: r 1.00 x 1.osa x 1 22a x s.so x 1.00 / 60] x 0 s 170 `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 25,804 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:21 of 35 f. RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #14D - The Hideaway 10/27/2004 Project Title Date Room Name Master & Guest Suites Design Indoor Dry Bulb Temperature: 740E Design Outdoor Dry Bulb Temperature: 116 F Design Temperature Difference: 420E Conduction Area U -Value X 0. X X X X X X X X X DETD 1 = = = = = = = = = Btu/hr 38.6 3,765 42.0 575 42.0 2,449 42.0 1,572 FxdGlsWdw (C2) 10.0 (North) FxdGlsWdvv F1 63 (East) Swn GIsDr 1208 7 (East) FXdGISWdW F2 t. Design Equivalent Temperature Difference (DETD) Page Total 8 361 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw D1 x+ xA,, x+ x x1 X x x x X (North) Fxdr,IsWAw-(E-1�--(North) 36.0 X X X x x x x x X X FxdGlsWdw E2 1� (North) FxdGlsWdw C1 180 (North) FxdGlsWdw (C2) 10.0 (North) FxdGlsWdvv F1 63 (East) Swn GIsDr 1208 7 (East) FXdGISWdW F2 i, (East) SwngGlsDr 105 °I (East) FXdGISWdW F5 t f> East ( 0.0 x+ xA,, x+ x x1 X x x x X + + + + + + + + 36.0 X X X x x x x x X X 15 ) X x )x x x x ) x x 0.334 = = = = = = = = = = 180 ( 0.0 10.0 15) 0.423 63 ( 0.0 10.0 15 0.423 63 ( 0.0 1 6.3 15)x 0.423 40 ( 0.0 6.3 15) 0.423 40 ( 0.0 1 24.0 73)X 0.423 741 ( 0.0 1 48.0 73) 0.312 1,092 ( 0.0 1 24.0 73) 0.423 741 ( 0.0 1 24.0 7 0.312 546 ( 0.0 1 1124..0 73) 0.423 741 Sched. Page Total 4,249 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,665 x 0.000 Watts/sqft X 3.413 Btuh/Waft = 0 Occu ants 1.00 X 1,665 X 0 Btuh/occ. . / 250 sgft/occ. = 0 Receptacle 1.00 x 1,665 x 0.200 Watts/sqft x 3.413 Btuh/Waft = 1,137 Process 1.00 X 1,665 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 1.00 x� x x x H / 60] chedule Air Sensible Area Ceiling Height ACnT 12.900 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,3841 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 x 1 665 x 0 Btuh/OCC. / 250 sgft/occ. = 0 lRotacle 1.00 X 1 665 x 0.000 Wafts/sgft x 3.41 BtuhfWatt = EEO Process 1.00 x 1 665 x 0.000 Watts/sqft x 3.41 BtuhMatt = Infiltration: 1 - ;]o X 477 X 1 665 x 10.40 X 1.00 / 60] . 0.00060 = -833 chedule Air Latent Area Ceiling Height ACH c.W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -833 lEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 22 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #14D - The Hideaway 10/27/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master & Guest Suites 740F 116°F 42°F Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total OJ I Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Swn GIsQr(110A) (South) ExdGIsWdw (FI) t? FxdGlsWdw Al --k (South) (West) FxdGlsWdw B1 1 4 (West) 32) X X X x )x )x )x )x )x )x 0.312 = = = = = = = = = = 239 ( 0.0 1 24.0 32) --0.423 ( 0.0 X X x x x X x x x x 1 + + + + + + + + + + 24.0 x X X X x X X X x x 32) X X X x )x )x )x )x )x )x 0.312 = = = = = = = = = = 239 ( 0.0 1 24.0 32) --0.423 325 ( 0.0 1 30.0 73) 0.423 926 ( 0.0 1 8.0 73) 0.423 247 ( ( ( ( ( ( Sched. Page -Total 1,738 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,665 x 0.000 Watts/sqft x 3.413 Btuh/Watt — 0 Occupants 1.00 X 1, 665 X 0 Btuh/occ. / 250 sgft/occ. = 0 Receptacle 1.00 x 1,665 x 0.200 Watts/sgft x 3.413 BtuhMatt = 1,137 Process 1.00 X 1,665 X 0.0000.000 Wafts/sgft X 3.413 Btuh[Watt = 0 Infiltration: �� x 1.osa xiS x E0401 x / 60] _ Schedule Air Sensible Area Ceiling Height ACH _\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,3841 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 sss x 0 Btuh/occ. / 2so sgft/occ. = o Receptacle 1.00 X 1 665 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Process 1.00 x 1 665 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 1.00 x 477 x 1 66 x 10.40 x1.00 / 60] -0.00060 = -833 --- chedule Air Latent Area Ceiling Height ACH _\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -833 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 23 of 35 -RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #14D - The Hideaway 10/27/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Great Rm/Dining/Entry/Hall 74°F 116°F .42°F Conduction Area U -Value DETD' Btu/hr x I S 59.0 = 1,918 x Swn GlsDr(N2)'t'r 38.6 = 1,457 x West 42.0 = 3,730 x 169 42.0 = 184 X 0.312 42.0 = 2,506 i� 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 9 794 ' Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Sld GlsDr 121 I S (East) 1cWrJw ((K11 Ito (South) Swn GlsDr(N2)'t'r X ) x )x x )X )X )X )X )X (West) Swn GIsDr 103A ($ West SwngGlsDr (M) JQ (West) 0.423 169 ( 0.0 48.0 73 0.312 1,092 ( 0.0 1 57.0 73) ( 189.6 XAll, X+ X+ x X X x X x x + + + + + + + + 50.4 X X X x x x x X x X 73) X ) x )x x )X )X )X )X )X 0.334 = = = = = = = 2,179 ( 0.0 12.5 32 0.423 169 ( 0.0 48.0 73 0.312 1,092 ( 0.0 1 57.0 73) 0.312 1,297 ( 0.0 1 48.0 0.312 1,092 ( -73)x ( ( ( ( Sched. Page Total 1 5,8291 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,261 x 0.000 Watts/sgft X 3.4d BtuhlWatt = 0 Occupants 1.00 X . 1.26 X 0 Btuh/occ. / 250 sgft/occ. = 0 Receptacle 1.00 x 1,261 x 0.200 Watts/sqft x 3.413 Btuh[Watt = 861 Process 1.00 x 1,261 x 00.000 Watts/sgft x 3.41 Bt�uh/Watt = 0 Infiltration: x oSg x 1261 x L�LBt x � / 60] Z'ST = �! chedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY SENSIBLE HEAT GAIN. FOR ROOM 27569 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 261 x 0 Btuh/occ. / 250 sgft/occ. = 0 Receptacle 1,00 X 1 261 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Process (� 1.00 x 1 261 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Infiltration: I 1.00 x 477 x 1 26 x ' 11.80 x 1.00 / 60] -0.00060 '--- chedule Air Latent Area Ceiling Height ACH �\w Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -715 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 24 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #14D - The Hideaway 10/27/2004 Project Title Date I Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Kitchen/Guest Office/Laundry 74DF 116°F 42°F Conduction Area U -Value DETD 1 Btu/hr X 7x, 59.0 = 1,861 X Sld GlsDr MA 38.6 = 3,342 X (East) 42.0 = 1,114 X S 42.0 = 1,290 X FXdGISWdW H2 42.0 = 995 X X X X t. Design Equivalent Temperature Difference (DETD) Page Total 8,601 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Swn GlOr 130A 7x, (North) FxdGIsWdw (174) z k (North) Sld GlsDr MA TZ. (North) FxdGlsWdw G1 23 (East) FxdGlsWdw (A3) (East) Swn GIsDr 1228 S (South) FxdGlsWdw H1 2/, South FXdGISWdW H2 I (South) FxdGlsWdw 11) 1 (South) Swn GIsDr 128B ^'i West ( 0.0xAll X+ x+ x x x X x x x + + + + + + + + 24.0x X X x x x X X X X 15)x )X ) x X X ) x 0.312= = = = = = =.. = __ = 112 ( 0.0 24.0 15 0.423 152 ( 0.0 64.0 15 0.334 321 ( 0.0 1 23.4 73)x 0.423 723 ( 0.0 1 15.0 73)x 0.423 463 ( 0.0 1 24.0 32) 0.312 239 ( 0.0 1 3.0 32)X ... 0.423 .... _ 4.1 ( 0.0 1 3.0 32) 0.423 41 ( 0.0 1 19.3 32)x 0.423 262 ( 0.0 1 20.0 73 0.312 455 Page Total Sched. 2 Bos Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,224 x 0.000 Watts/sqft X 3.41 Btuh/Watt = o Occupants 1.00 X 1,224 X 0 Btuh/occ. / 250 sgft/occ. = 0 Receptacle 1.00 x 1,224 x 0.200 Watts/sqft x 3.413 Btuh/Watt = 836 Process r 1.00 x 1,224 x �0.0�00 Watts/sgft x 3.41 Btuh/Waft = 0 Infiltration: j ch� xAIrs�UbSJ x A 224 x x / 60] Ceiling _ ght ACH Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,999 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 X 1 224 x 0 Btuh/occ. / 25 sgft/occ. = 0 [Receptacle 1.00 x 1 224 x 0.000 Wafts/sgft x 3.41 Btuh/Watt = 0 Process I� 1.00 x 1 224 X 0.000 Watts/sgft x 3.41 BtuhMatt = o Infiltration: I 1.00 x 4 77 x 1 224 x 9.60 x 1.00 /601 -0.00060 --- chedule Air Latent Area, Ceiling Height ACH \W. Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -565 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 25 of 35