Loading...
07-1728 (SFD)01 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ' u�iK,tw 1 ,1 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: -i 07-000017.28 Property Address: 53148 VIA DONA APN: 772-410-999-16 -298944- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 498684 Applicant: Architect or Engineer: L G AL Owner: LAWRENCE & DIANE ZIRINSKY P.O- BOX 2006 RANCHO SANTA FE, CA 92067 (r Contractor: PIERCE CORPORATION, A] P.O. BOX 3420 PALM DESERT, CA _92261. (760)346-3228- Lic. No.: 671203 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 1. Date: 9/19/07 OCT 032007 "D LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.�, 671203 • for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. /Date: contractor: a _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ' - Code, for the performance.of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 1828004-2007 following reason (Sec. .7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for. which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the ' person in any manner so as to become subject to the workers' compensation laws of California, - ' permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provision of Section License Law (Chapter 9 (commencing with'Section 7000) of Division 3 of the Business and Professions Code) or that hF she and the basis for the alleged exemption. Any violation Section 7031.5 by exempt therefromsubjects � 3700 of the Labor Qodp, I sh I forth ith comply with hoseprovisions. / J '/ ► f � d an applicant for a permit sub'ects the applicant to a civil penalty of not more than five hundred dollars (S500).: o ool I0 Date: �/Applicant: IYYAtI 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and I _ the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner -of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, 'DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purposeof sale.).' APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044,. Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,, 1 1 I am exempt under Sec._ , BAP.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City . Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address LQPERNIIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. • 2. Any permit issued as a result of this application becomes null and void if work is not commenced 'Within 180 days from date of issuance of such permit, orcessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this co ty o enter upon the above-mentioned prop ty far i sJ�Ile/cttiiory/��purposes. Date: Si nature (Applicant or Agent): r . LQPERD7IT -Application Number . . . 07-00001728 ------ Structure Information 5708 SF SFD ----- Other struct info . . CODE EDITION 01BMP04E05EN #. BEDROOMS, 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1106.00 PATIO SQ FTG 1188.00 NUMBER OF UNITS 1.00 •. 1ST FLOOR SQUARE FOOTAGE 5708.00- 708.002ND 2NDFLOOR SQUARE FOOTAGE .00 Permit BUILDING PERMIT Additional desc 5,708 SF RESIDENCE Permit Fee . . . 2036.00 Plan Check Fee 1323.40 Issue Date . . . . Valuation . . 498684 Expiration Date 3/17/08 Qty Uni't_Charge. Per Extension BASE FEE r 639.50 399.00 3.5000 THOU_ BLDG 100,001-500,000 1396.50 Permit . . ELEC-NEW-RESIDENTIAL Additional-desc . Permit -Fee . . . . 273.66 Plan Check Fee 68.42 Issue Date. Valuation . . . 0 Expiration Date •3/17/08 Qty Unit Charge .Per Extension BASE FEE 15.00 5708.00 0350 ELEC NEW RES - l OR•2 FAMILY 199.78 2194.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 43.88. 1.00 15.0000 EA ELEC TEMPORARY POWER -POLE 1,5.00 Permit MECHANICAL Additional desc . Permit Fee . . . 220:00 Plan Check Fee 55.00 Issue Date Valuation 0 Expiration Date,-. 3/17/08 Qty Unit Charge Per Extension BASE -FEE 15.00 6.00 9.0000 EA MECH FURNACE.<=100K 54.00 6.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 99.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 . LQPERD7IT LQPERIMIT - Application Number . . . . . 07-00001728 . Permit PLUMBING Additional-desc . . Permit Fee . . ." 229.50 Plan Check Fee 57.38 Issue Date Valuation 0. Expiration Date .. 3/17/08 Qty Unit Charge Per Extension BASE.FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 -1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3".0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER -SYSTEM. 9.00 1.00 15.0000. -EA PLB OTHER BACKFLOW•,>2 INCH 15.00 , " 1.00 3.0000 EA PLB.GAS PIPE 1-4 OUTLETS 3•.00 10.00 .7500 EA PLB GAS PIPE >=5 7.50 1.00 15.0000..EA PLB GAS METER 15.-00 Permit GRADING PERMIT Additional desc - Permit Fee 15:00 Plan Check Fee .00 Issue Date Valuation 0 Expiration -Date 3/17/08 Qty Unit Charge. Per Extension " BASE FEE 15.00' ------------ - -----Special Notes and Comments 5,708 SF SFD: R-3.00CUPANCY.TYPE V -N CONSTRUCTION.2001 CBC,CMC,CPC, 2004: " CEC, 2005 ENERGY CODES.2006 DIF Other Fees ART IN PUBLIC PLACES -RES 746.71 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES. 995.00 ENERGY REVIEW FEE 132.34 DIF FIRE PROTECTION -RES 140.00 DIF LIBRARIES"- RES 355.-00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC•- RES 892.00 STRONG MOTION (SMI) - RES 49.86 DIF STREET MAINT FAC -RES 67.00 - DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due LQPERIMIT - Application Number _ 07-00001728 -- Permit Fee Total -------- 2774.16 --------- .00 ---------- .00, 2774.16 Plan Check Total 1504.20 750.00 .00 754.20 Other Fee Total 5403.91 00' .00 5403.*91 Grand Total 9682.27 750..00. .00 8932.27 - LQPERAIIT - . Adddress 1&4444" P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO (J LA QUINTA, CALIFORNIA 92253 vwi ici I At. hrvtAl o 64T'�i�A-1 -7 1-:—.11,"__ � Address'PO. 'Bv X sot) City lZip ITO. Vie, I q 1611 ("&&1 Contractor I�cr�drua 'Pi w� o � Address 'P0.1309 3`i'LD State Lic. City I & Classif. _ 4`1 1 n I Lic. #!1. 4,1- 1 1t W0))Yr,CQ.G%1 I ft(/j(,o ILic. #f -H' LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 0 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions or the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit whenproperly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST. V- - 3 OCC. GRP. V " A.P. Number 112 - 5L0- Oso Legal Description LGA' lVy fiYGLc.,,r Z-IsgI+ -3 Project Description t, rhr+4- �� vzo qe D 3 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Sq. Ft. No. ' Size G� q Stories No. DIN. Units 2 New Add O Alter ❑ Repair ❑ Demolition ❑ Estimated aluation PERMIT, AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. ElectricalMY T Plumbing S.M.I. cl Op r Grading Driveway Enc. T, Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MMGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: IJITtALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Zirinsky FamilyTrust Date: 10/03/07 Owner's Name: Zirinsky Family Trust Phone No. (760) 346-3228 Project Address: 53-148 Via Dona, La Quinta, CA 92253 Project Description: 1 Single Family Dwelling APN: 777-380-0145 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 5,708 sq. Ft. Certification of Appticant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 10/03/07 Signature: *****ss******s*s*******sss****s**s*ss*******s***s**********s**s******** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 5,708 sq. ft. Amount per Sq.Ft. $ 3.48 Amount Collected $ 19,863.84 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mvdocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T DOC IS 2004-0210091 LIY NATIONAL TITLE COMPANY 08:00A Fee:16.00FiI): SUBDIVISION DEPARTMENT Page 1 of 4 Doe T Tax Paid WHEN RECORDED MAIL TO: RecordedCountyoff ficiRiversideeords, Mr. and Mrs. Lawrence Zirinsky Gary L. Orso Assessor, County Clerk 8 Recorder P.O..Box 2003 Rancho Santa Fe, CA 92067-2003 _ I IIIIII IIIIII VIII) VIII III IIIIIII VIII III Hill 1111111111 MAIL TAX STATEMENT TO: SAME AS ABOVE M- S V PACE 51ZE OA PCOR —OR SMff I.nSC A R L COPY LONG REFUND NCRO EXM1 DOCUMENT TRANSFER TAX $ 495.00 XX Computed on the consideration. or value of property conveyed; OR of Computed on the consideration or value less liens or encumbrances S / remaining at the time of sale. G 77d, f L/d -0_3� Signature of Declarant or Agent determining tax - Firm Name Q GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S)to Lawrence Zirinsky and Diane M. Zirinsky, Trustees of The Zirinsky Family Trust Dated May 10, 2001 , ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: -3(g t 0`' ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited 1'bility company its managing ber / By: Josephl. Arenson Authorized Representative y � . � ". • Y 1. .Y` STATE OF California COUNTY OF Riverside On March 8. 2004 before me, K Larbye Notary Public (Name, Title of Officer) personally appeared Joseph L. Arenson personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf, of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. OFFIOAL SEAL K_ LARRY COMM * 1268797 lip Notary Public - California ature(Sig Ota Pub iC) - c7RIVERSIDE COUNTY My Commission Expires )UNE 24, 2004 (This area for notarial seal) EXHIBIT "A» Legal Description Parcel No. 1: Lot 16 (the "Lot") of Tract No. 29894-4, in the City of La Quinta, as shown by Map on file in Book 351, Pages. 49 to 57, inclusive, of Maps, in the Office of the County Recorder of Riverside County, California. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas reserved to Grantor in the following instruments: and other portion of the Lot, 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745938, of Official Records of Riverside County, California (the "Official Records"); 2. The Supplementary Declaration of Annexation of Property, recorded on March 4, 2004, as Instrument No: 2004-0151981 of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. ' Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. .ParcelNo. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: I . Non delinquent general, special and supplemental real property taxes and assessments. v 2. All other covenants; conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-4. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined above, on 0, 2004. Zawre ZIRINSKY FAMILY TRUST Dated May 2001 nce nsky, Trdstee Diane M. Zirins , Trustee STATE OF COUNTY OF J r• 9 s ) On r c �, ! 9 __ 2004, before me, the undersigned, a notary public in and for said State, personally appeared Lawrence Zirinsky and Diane M. Zirinsky personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. [SEAL] Signature My commission expires: STMEVE GRAY y COMM. #1425813 U NOTARY MC - CX FORN�A SAN DS:GO COUMY Y C0MMWW Emotes JWY 19.2007 Applicatieon ;;I nqui ry- BPN2 n 0I 1): `�' all SLOGARa PUBLIC SECTOR. NaviUh—e �.... g . Application 07-00001728 ,4i — Bonds P' "Property Information - �� -Application Information —� —� Contractor escrow Address: 53148 VIA DONA Application desc: 5,708 sf SFD j — 4r Fees LA QUINTA, CA 92253 1 Application status: PERMIT ISSUED Global -balance due Location,ID: _ 47196 ' Status Date: 1/26/2009 �/ Irn pection historyOwner name: NRI CCP I Application type: l7NELLING}- SINGLE FAhIILY, DET ( Miscellaneous inform APN: 772-410-999-16 '=298944= Application date: 6/15/2007 �1 Names Alternate ID: _ I Valuation: 498684 , — Permits Zoning: RL LOIN DENSITY 'RESIDENTIAL © Plan tracking ......... ......... ............. •.....:•: ......... ......... ......... :::;::::.... ......... .::.:.... ......... ......... :......... ..........:.. j I® Receipts- , - Insp Seq Inspector Schedule date r Square footage calcul 1000 000 jB001 00 IFOOTINGS 0001 ST, 12/05/2007 1 A Structures 000- 000 B001:,00 FOOTINGS 0.002 . ST:•_ _ 12 _19 2007.-" __; �A r Valuation calculation 000 000 B001 00 ISLAB 0001 ST - 12/13/2007 A FOOD '000 B00.1„00, ROOF NAIL _.. . _ 0001 FT— :ST. , - ,,3 21 -2008. .' ',-A 00 00 00 B001 00 OKAY TO WRAP 0001 AO/1112008 A 000.!000, 5001 00;' IFRAMING: 0001 .., AO- -- __' :6/1372008 A 000 000 B001 00 JINSULATION 0001 F Ap 1 6/25/2008 A 000 000:: B001 00 LATH _ 0001 = AO _, tu7/09 ,2.008' _ -.• .A 000 000 B001 00'' DRYWALL NAIL _ 0001 AO _ F 7/09 2008.._ _.:A 000.,000,; B001.-00.,✓ FINAL .: _ _ .. = _ ” 0001; ST;_.: ,... :,11.2;0 200T_7_ . T -A 000 000 E01 00 ITEMPORARY POWER 10001 1 EM F 10 F A 000 ;000, E01_ _00 UNDERGROUND ELECTRICAL_- `.,• --_ 0001 _' _ ST.;-_ r 1.1/29/2007; � ,_aA 000 000 E01 00 ROUGH ELECTRICAL 0001 F AO n13 2008 A. y ll 1000-000.008 _EQ1, _00,, TEMP,=USE_ OF PERMANENT,,POWER 0001- ,_: ST_ .. -t ;. 9.-1-67T- F. ._ _A r.�= _.. 000 000 E01 00 ELECTRICAL FINAL 0001 ST 11 20 2008 ' A " Pnntr..- 000 :000._' GP; , .00,:: -:. GRADING• FINAL-.--- - .-. T_ _ — _ _ 0001=.;,. i ST,_ T ,` _11:20 2008_ _ _ -A =�� - 000 000 !M01 00 ROUGH MECHANICAL 0001 AO x/13/2008..• A """1" w .4,+Cancer �_h 000 000 !MO1 00 MECHANICAL FINAL.r 0001 ST.11/20/2008 A 000 000 P01 00 UNDERGROUND PLUMBING 0001 ST" 11%06/2007 A Exit 1 :... :. 000' 000`.1 PO1 00 " SEWER` CONNECTION 0001 ST _ � 04/2008" - A - 000 000 P01. 00 ROUGH PLUMBING 0001 AO 6 13 2008 A .: az Ref es 000 000 P0100 �_ GAS�LINE, � GAS^TEST- __ _ Y : - _ _� 4 0001 _..>i _.ST, _ 1 .�-8;-2_1 2008 A "'-' Land Inquiry, , ,•. 000 000 P01 00 _ PLUMBING FINAL 0001 ST_ .11 20/2008; A ��._ is1 Documents ��' .-,}.� • ,'irk ♦' .• ., n .. y }• s: - at. �„�"rss>ria�. y^i'']� � �A �'�,�.i}„ '� p S. � 69w �'t pt �;�!•' .i ¢� N a. r.-� S� � f's _ .. •�� � "F -y � « r _ ,- Certificate ofOccupancy- coi,.,. �IGGI�iit/ OF9Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the. City regulating building construction and/or use. BUILDING ADDRESS: 53-148 VIA DONA Use classification: SINGLE FAMILY DWELLING Occupancy Group: R-3 Type of Construction: V -N Owner of Building: LAWRENCE & DIANE ZIRINSKY !d��t Building Official POST IN A Building Permit No.: 07-1728 Land Use Zone: RL Address: P O BOX 2006 City, ST, ZIP: RANCHO SANTA FE, CA 92067 By: STEVE TRAXEL Date: NOVEMBER 20, 2008 S PLACE -fI CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -4R Project Address (The Zadnsky Residence) : t , Duct Pressurization Test Results (CFM @ 25 Pa) r'i Builder or Installer Name 53148 Via Dona (The Hideaway) / La Quinta,-CA 92253 - Andrew Pierce Corporation Builder or Installer Contact "' - 'Telephone Plan/Permit (Additions or Alterations) Number Paloma Air Conditioning d (760) 564-5657 HERS Rater Telephone Sam le Grou Number N/A 1, Christopher Mcfadden - CHEERS Rater #CCNCM275794 760 449-1308 Compliance Method rescri"iive Performance= - Climate Zone 15 Certifying Signature Date Sample House Number ' PQ Pass ❑ Fail 11/8/2008 N/A FirmHERS Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to Provider CM Energy Consulting P• ,, CIHIEIEIRIS' .Street Address: City/State/Zip: J0. 0. Box 4655 Palm Desert, CA 92211 Uoples to: ISUILIMA, HE" FMMUEK AND BUILUL G DEFAK'1'MEN-F HERS RATER COMPLIANCE STATEMENT ' ' ' The house was: ✓ ® Tested ✓ ❑ Approved as part of sample testing, but was noftested As the HERS rater providing diagnostic testing and field verification, I certify ihat the house identified on this form complies with the`diagnostic tested compliance requirements as checked ✓ on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must'not release the CF -4R until a properly completed and signed CF -6R has been received for t rl a sample and tested buildings. ' The installer has provided a copy of CF -6R (Installation Certificate).-,- New ertificate).-,New ducts are fully ducted (i.e., does not use building cavities as plenums or -platform returns in lieu of ducts). - EI New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Results 9 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) r'i Measured Values I Enter Tested Leakage Flow in CFM: 95 cfm 2 Fan Flow: Calculated (Nominal: ✓ 90 Cooling ✓ ❑ Heating) or !.❑ Measured Enter Total Fan Flow in CFM: ' 1,600 cfm 3 Pass if Leakage Percentage < 6% [ 100 x [--2.5 (Line # 1)�/ 1,600 (Line # 2)]] 5.9% PQ Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out - . k Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System_ or Altered Duct System 5 for Duct System Alteration and/or Equipment Chana-Out. Enter Reduction in Leakage for Altered Duct System L_(Line # 4) Minus (Line # 5)] .6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) - Entire New Duct System - Pass if Leakage Percentage < 6% ` 8 r 100 x[_(Line # 5 / Line # 2 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out Use one of the following four Test or Verification Standards for com liance: 9 Pass if Leakage Percentage < 15% [100 x L_(Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10%.[100 x L -(Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x L_(Line # 6) / (Line # 4)]] and Verification b Smoke Test and Visual Inspection ,..- ❑pass ❑Fail Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection - ❑ Pass ❑ Fail Pass if One of Lines # 9 through # 12 pass ❑ Pass ❑ Fail "t , N • Residential Compliance Forms - ' December 2005 I I CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) Builder Name 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Andrew Pierce Corporation Builder Contact Telephone Plan Number Paloma Air Conditioning (760) 564-5657 ✓ HERS Rater Telephone Sample Group Number N/A Christopher Mcfadden - CHEERS Rater #CCNCM275794 760 449-1308 Compliance Method (Prescriptive) Climate Zone 15 Certifying Signature Date Sample House Number 11/08/2008 N/A Firm I Fail HERS Provider CM Energy Consulting CJHJEJEJRJS' Street Address: City/State/Zip: P.O. Box 4655 Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT , HERS RATER COMPLIANCE STATEMENT The house was: v" 91 Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM,, Appendix RI. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charee Measurement (outdoor air dry-bulb 55 °F and above): ' Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. Fo Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 Access is provided for inspection. The procedure shall consist of ✓ PQ Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charee Measurement (outdoor air dry-bulb 55 °F and above): ' Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. Fo Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 -4t- 2 - CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -4R CERTIFICATE Project Address (The Zarinsky Residence) Duct Pressurization Test Results (CFM@ 25 Pa) ` Builder or Installer Name 53148 Via Dona (The Hideaway) / La Quinta, CA 92253. ,• Andrew Pierce Corporation Builder or Installer Contact Telephone Plan/Permit (Additions or Alterations) Number Paloma Air Conditioning (760) 564-5657 HERS Rater Telephone Sample Group Number N/A Christopher Mcfadden - CHEERS Rater #CCNCM275794. ' -(760)449-1308 Compliance Method (Prescriptive) Performance 800 cfm Climate Zone 15 Certifying Signature Date Sample House Number M Pass ❑ Fail 11/8/2008- N/A Firm Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to HERS Provider CM Energy Consulting 4 CJHJEJEJRJ! Street Address: City/State/Zip: P.O. Box 4655 Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓ E Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked %/ on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must not release the CF4R until a properly completed and signed CF -6R has been received for the sample and tested buildings. M The installer has provided a copy of CF -6R (Installation Certificate). M New ducts are fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). �I New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in -combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Results NEW CONSTRUCTION: Duct Pressurization Test Results (CFM@ 25 Pa) ` Measured Values I Enter Tested Leakage Flow in CFM: 47 cfm 2 Fan Flow: Calculated (Nominal: ✓ 90 Cooling ✓ ❑ Heating) or ✓ ❑ Measured Enter Total Fan Flow in CFM: 1 800 cfm ✓ ✓ 3 Pass if Leakage Percentage < 6% [ 100 x [ A7 (Line # 1) / 800 (Line # 2)]] 5.9% M Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 for Duct System Alteration and/or Equipment Chane-Out. Enter Reduction in Leakage for Altered_ Duct System [_(Line # 4) Minus (Line # 5)] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ Entire New Duct System - Pass if Leakage Percentage < 6% g 100 x [-(Line # 5 / Line# 2 - ❑Pass ❑Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out ✓ Vol Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% [100 x L --(Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage <.10% [100 x [-(Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x L(Line # 6) / (Line # 4)]] . 11 and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if ealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail • Pass if One of Lines # 9 through # 12 pass ❑ Pass ❑ Fail Residential Compliance Forms December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Builder Name Andrew Pierce Corporation Builder Contact Paloma Air Conditioning Telephone 760 564-5657 Plan Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone 760 449-1308 Sample up Number N/A Compliance Method (Prescriptive) ✓ Climate Zone 15 Certifying Signature Date 11/08/2008 Sample House Number N/A Firm 4f CM Energy Consulting HERS Provider CJHJEJEJRJS Street Address: P.O. Box 4655 installation of the specific equipment shall be verified. City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM, Appendix RI. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ ❑ Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 ✓ ✓ Access is provided for inspection. The procedure shall consist of ✓ PQ Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ ❑ Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Duct Pressurization Test Results (CFM @ 25 Pa) - Builder or Installer Name Andrew Pierce Corporation Builder or Installer Contact Paloma Air Conditioning Telephone (760) 564-5657 Plan/Permit (Additions or Alterations) Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone (760) 449-1308 Sample Group Number N/A Enter Tested Leakage Flow in CFM: ' Compliance Method (Prescriptive) Performance Climate Zone 15 Certifying Signature Date 11/8/2008 Sample House Number N/A Firm CM Energy Consulting Enter Total Fan Flow in CFM: HERS Provider CJHJEJEJRJS Street Address: P.O. Box 4655 3 City/State/Zip: Palm Desert, CA 92211 Uopies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT = HERS RATER COMPLIANCE STATEMENT The house was: ✓ ® Tested ✓. ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked v" on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must not release the CF4R until a properly completed and signed CF -6R has been received for t rumple and tested buildings. ; ' ' III The installer has provided a copy of CF -6R (Installation Certificate). , N New ducts are fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). 11 New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Results - NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) - Measured Values 1. Enter Tested Leakage Flow in CFM: ' 64 cfm 2 Fan Flow: Calculated (Nominal: ✓ M Cooling ✓ ❑ Heating) or ✓ ❑ Measured Enter Total Fan Flow in CFM: 1,600 cfm ✓ ✓ 3 Pass if Leakage Percentage < 6% [ 100 x f §A . (Line # 1) / 1,600 (Line # 2)]] 4% M Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 for Duct System Alteration and/or Equipment Change -Out., Enter Reduction in Leakage for Altered Duct System [_(Line # 4) Minus (Line # 5)] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ Entire New Duct System - Pass if Leakage Percentage < 6% 8 100 x Line # 5 / Line # 2 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out ✓ ✓ Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% [100 x L -(Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 106/o [100 x f (Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x [-(Line # 6) / (Line # 4)]] 11 and Verification by Smoke Test and Visual Inspection ❑ pass ❑ Fail Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if One of Lines # 9 through # 12 pass ❑ Pass ❑ Fail Residential Compliance Forms December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Builder Name Andrew Pierce Corporation Builder Contact Paloma Air Conditioning Telephone (760) 564-5657 Plan Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone 760 449-1308 Sample Gro u Number N/A Method (Prescriptive) ✓ Climate Zone 15 -Compliance Certifying Signature Date 11/08/2008 Sample House Number N/A Firm CM Energy Consulting HERS Provider CJHJEJEJRJS Street Address: P.O. Box 4655 installation of the specific equipment shall be verified. City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as'checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM, Appendix R1. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 OF and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -611 before starting this procedure. If outdoor air dry-bulb is below 55 OF rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. F ii -Y:- ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 Access is provided for inspection. The procedure shall consist of ✓ PQ Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chara for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 OF and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -611 before starting this procedure. If outdoor air dry-bulb is below 55 OF rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. F ii -Y:- ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -4R Project Address (The Zarinsky Residence) Duct Pressurization Test Results (CFM @ 25 Pa) Builder or Installer Name 53148 Via Dona (The Hideaway) / La Quinta; CA 92253 Andrew Pierce Corporation Builder or Installer Contact Telephone Plan/Permit (Additions or Alterations) Number Paloma Air Conditioning (760) 564-5657 HERS Rater 4 , Telephone Sample Grou0 Number N/A Christopher Mcfadden -CHEERS Rater #CCNCM275794 (760) 449-1308 Compliance Method (Prescriptive) Performance 800 cfm Climate Zone 15 Certifying Signature Date Sample House Number [81 Pass ❑ Fail 11/8/2008 N/A Firm Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to HERS Provider CM Energy Consulting 4 CIHIEIEIRIS' Street Address:- City/State/Zip: - P.O. Box 4655 Palm Desert, CA 92211 Uoples to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT , The house was: ✓ ® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS raterproviding diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked ✓ on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a. CF -4R may be released on every tested building. The HERS rater must not release the CF4R until a properly completed and signed CF -6R has been received for the sample and tested buildings. N The installer has provided a copy of CF -6R (Installation Certificate). �I New ducts are fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). gl New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Resulti ' NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values I Enter Tested Leakage Flow in CFM: 44 cfm 2 Fan Flow: Calculated (Nominal: ✓ 90 Cooling ✓ ❑ Heating) or ✓ ❑ Measured Enter Total Fan Flow in CFM: F* 800 cfm ✓ ✓ 3 Pass if Leakage Percentage < 6% [ 100 x L --L4 : (Line # I) / 800 (Line # 2)]] 5.5% [81 Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 , Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 for Duct System Alteration and/or Equipment Chana-Out. Enter Reduction in Leakage for Altered Duct System L_(Line # 4) Minus (Line # 5)] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ Entire New Duct System - Pass if Leakage Percentage < 6% 8 100 x[ -(Line # 5 / Line # 2 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment•Change-Out ✓ ✓ Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% [100 x L -(Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [100 x r(Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x r (Line # 6) / (Line # 4)]] 11 and Verification by Smoke Test and Visual Inspection , ❑ pass ❑ Fail Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass Cl Fail ' ii Pass if One of Lines # 9 through # 12 pass ❑ Pass ❑ Fail Residential Compliance Forms December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Builder Name Andrew Pierce Corporation Builder Contact Paloma Air Conditioning Telephone 760) 564-5657 Plan Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone 760 449-1308 Sample G up Number N/A Compliance Method (Prescriptive) ✓ Climate Zone 15 Certifying Signature Date 11/08/2008 Sample House Number N/A Firm 61f. CM Energy Consulting HERS Provider CJHJEJEJRJS Street Address: P.O. Box 4655 installation of the specific equipment shall be verified. City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: V 9 Tested ✓ ❑ Approved as part of sample testing, but was, not tested As the HERS raterproviding diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM, Appendix R.I. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling CapacityBtu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ ❑ Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 ✓ ✓ Access is provided for inspection. The procedure shall consist of ✓ 00 Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling CapacityBtu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ ❑ Yes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -4R Project Address (The Zarinsky Residence) , 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Duct Pressurization Test Results (CFM @ 25 Pa) _ Builder or Installer Name Andrew Pierce Corporation Builder or Installer Contact Paloma Air Conditioning Telephone (760) 564-5657 Plan/Permit (Additions or Alterations) Number HERS Rater Christopher Mcfadden - CHEERS Rater #6CN6M275794 Telephone 760 449-1308 Sample Group Number N/A Enter Tested Leakage Flow in CFM: Compliance Method (Prescriptive) Performance Climate Zone 15 Certifying Signature Date 11/8/2008 Sample House Number N/A Firm CM Energy Consulting Enter Total Fan Flow in CFM: HERS Provider CIHIEIEIRIS' , Street Address: P.O' Box 4655 3 1 City/State/Zip: Palm Desert,- CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓ ® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification' I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked ✓ on this ?z rm. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must not release the CF -4R until a properly completed and signed CF -6R has been received for t it a sample and tested buildings. IKI The installer has provided a copy of CF -6R (Installation Certificate). Ii1 New ducts are fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). EI New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Results NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) _ Measured Values 1 Enter Tested Leakage Flow in CFM: 58 cfm 2 Fan Flow: Calculated (Nominal: ✓ �j Cooling✓ ❑ Heating) or ✓ ❑ Measured 200 Enter Total Fan Flow in CFM: 1 cfm, ✓ ✓ 3 1 Pass if Leakage Percentage < 6% [ 100 x( 58 (Line # 1) / 1,200 (Line # 2)1] 4.8% M Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 for Duct System Alteration and/or Equipment Chane-Out. Enter Reduction in Leakage for Altered Duct System [_(Line # 4) Minus - (Line # 5)] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ 8 Entire New Duct System - Pass if Leakage Percentage < 6% ❑ Pass ❑ Fail 100 x[ -(Line # 5 / Line # 2 TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out ✓ ✓ Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% [100 x [_(Line # 5) / ' (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [100 x L(Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x f ' (Line # 6) / (Line # 4)]] 11 and Verification b Smoke Test and Visual Inspection ❑pass ❑Fail Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass❑ Fail Pass if One of Lines # 9 through # 12 pass 13Pass ❑ Fail CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Builder Name Andrew Pierce Corporation Builder Contact Paloma Air Conditioning Telephone (760) 564-5657 Plan Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone 760 449-1308 Sample G up Number N/A Compliance Method (Prescriptive) ✓ Climate Zone' 15 Certifying Signature set Date 11/08/2008 Sample House Number N/A Firm I CM Energy Consulting HERS Provider CJHJEJEJRJS' Street Address: P.O. Box 4655 installation of the specific equipment shall be verified. City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: V 9 Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS raterproviding diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ' ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM, Appendix R1. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make. Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above) Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ 0 Yes O No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 Access is provided for inspection. The procedure shall consist of ✓ 09 Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Charge for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make. Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 °F and above) Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 °F rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. ✓ 0 Yes O No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge measurement documented. Residential Compliance Forms April 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) • CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253. Duct Pressurization Test Results (CFM @ 25 Pa) Builder or Installer Name Andrew Pierce Corporation Builder or Installer Contact Paloma Air Conditioning Telephone (760) 564-5657 Plan/Permit (Additions or Alterations) Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone 760 449-1308 Sample Gro u Number N/A Enter Tested Leakage Flow in CFM: Compliance Method (Prescriptive) Performance Climate Zone 15 Certifying Signature Date 11/8/2008 Sample House Number N/A Firm CM Energy Consulting Enter Total Fan Flow in CFM: HERS Provider CJHJEJEJRJ! Street Address: P.O. Box 4655 3 City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HENS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓ ® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked ✓ on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building. The HERS rater must not release the CF4R until a properly completed and signed CF -6R has been received for rumple and tested buildings. 1 M The installer has provided a copy of CF -6R (Installation Certificate). SSI New ducts are fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts). El New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.). ✓ ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RACM, Appendix RC4.3. Duct Diagnostic Leakage Testing Results NEW CONSTRUCTION: < Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values I Enter Tested Leakage Flow in CFM: 52 cfm 2 Fan Flow: Calculated (Nominal: ✓ 90 Cooling ✓ ❑ Heating) or ✓ ❑ Measured Enter Total Fan Flow in CFM: 1,200 cfm ✓ ✓ 3 Pass if Leakage Percentage < 6% , [ 100 x L--.52 (Line # 1) / 1,200 (Line # 2)]] 4.3% M Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to 4 Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 for Duct System Alteration and/or Equipment Change -Out. Enter Reduction in Leakage for Altered Duct System L_(Line # 4) Minus (Line # 5)] 6 (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ Entire New Duct System - Pass if Leakage Percentage < 6% 8 . 100 x [—(Line # 5 / Line # 2 ❑Pass ❑Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out ✓ ✓ Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% [100 x [_(Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [100 x [_(Line # 7) / : (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x [_(Line # 6) / (Line # 4)]] 11 and Verification b Smoke Test and Visual Inspection ` 11 Pass ❑Fail Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if One of Lines # 9 through # 12 pass ❑ Pass ❑ Fail Residential Compliance Forms w December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 8) CF -4R Project Address (The Zarinsky Residence) 53148 Via Dona (The Hideaway) / La Quinta, CA 92253 Builder Name Andrew Pierce Corporation Builder Contact Paloma Air Conditioning Telephone 760) 564-5657 Plan Number HERS Rater Christopher Mcfadden - CHEERS Rater #CCNCM275794 Telephone (760) 449-1308 Sample Group Number N/A Compliance Method (Prescriptive) ✓ Climate Zone 15' Certifying Signature 4� 6/:::�= Date 11/08/2008 Sample House Number N/A Firm 4f CM Energy Consulting HERS Provider CIHIEIEIRIS' Street Address: P.O. Box 4655 installation of the specific equipment shall be verified. City/State/Zip: Palm Desert, CA 92211 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT HERS RATER COMPLIANCE STATEMENT The house was: ✓® Tested ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. ✓ ® The installer has provided a copy of CF -6R (Installation Certificate). ✓ ® THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RACM,, Appendix R1. ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chare for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 OF and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 OF rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. F iiYes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge ii measurement documented. Residential Compliance Forms April 2005 Access is provided for inspection. The procedure shall consist of ✓ 00 Yes ❑ No visual verification that the TXV is installed on the system and ® ❑ installation of the specific equipment shall be verified. Yes is a pass Pass Fail ✓ ❑ REFRIGERANT CHARGE MEASUREMENT Verification for Required Refrigerant Chare for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Model Cooling Capacity Btu/hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (must be checked monthly) Standard Charge Measurement (outdoor air dry-bulb 55 OF and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications and installer verification shall be documented on CF -6R before starting this procedure. If outdoor air dry-bulb is below 55 OF rater shall use the Alternative Charge Measure Procedure Procedures for Determining Refrigerant Charge using the Standard Method are available in RACM Appendix RD2. F iiYes ❑ No A copy of CF -6R (Installation Certificate) has been provided with refrigerant charge ii measurement documented. Residential Compliance Forms April 2005 Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-49S Calle Tampico U Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 8 17-91- Project Address: %114 MWA Owner's Name: 21osy- A. P: Number: 'Q Address: V. . sox906 Legal Description: 16 V City, ST, Zip: Contractor: Address: .44-mr, OW Telephone: Project Description: ST, Zip:r" /„ L� 7 ' rZ.,.City, Telephone:'1�, State Lic. # : City �, Arch., Engr., Designer: +� Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person:IM Construction Type: Occupancy: . Project type (circle one): New. Add'n Alter Repair'Demo Sq. Ft.: #Stories: #Units: Telephone # of Contact -Person: ?j Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE . # Submittal Retj'd Recd TRACMG . PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy.Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan" 2°" Review, ready.for correctionissue 1 Electrical Subcontactor.List Called'ContactPerson7, I Plumbing Grant Deed Plans, picked up S.M.I. H:O.A. Approval • Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/Issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees TITLE 24 REPORT Title 24 Report for: 53148 Via Dona - La Quints , CA 92253 Project Designer: AA Group_ 20341 Sw Birch St #320 Newport Beach, CA 92660 949-250-1.909 Report Prepared By: Micah Combs - C.M. Energy Consulting CITY OF LA QUINTA P.O. Box 4.655 BUILDING & SAFETY DEPT. Palm Desert, CA 92261_: APPROVED(760) 449-1-308,1FOR C NSTRUCTION DATE6 (� BY Job Number: +Date: P6 7 8/15/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance rep • y is program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed byfnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 1086 I RESIDENTIAL ROOM COOLING LOAD SUMMARY I Project Title Date Zirinsky Residence 18/15/2007 Room Information Design Conditions Room Name: Game Room Outdoor Dry Bulb Temperature: 1120F Floor Area: 600 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F opaque AurTaces R-38 Roof R.38.2x14.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 Orientation Area X X X X X X X x X X x x - U -Factor X X X X X X X X X X X X CLTD 1 = = = = = = = = Btu/hr GLF N 600.0 0.0180 56.0 605 E 90.0 0.0690 33.0 205 (SE)' 70.0 0.0690 31.0 150 S 178.5 0.0690 26.0 320 SW 294.0 0.0690 31.0 629 NW 320.0 0.0690 30.2 667 21.2 191 S 0.0 21.1 22.5 21.2 477 S 0.0X 18.7+ 21.0X 18.8= 395 Pa e Total 2 576 Items shown with an asterisk (') denote conduction through an interior surface to another room. g 1. Cooling Load Temperature Difference (CLTD) Fenestration (Vertical Slider (17) 1 0 Orientation Shaded Area x x X x X X x x X x GLF + + + + + + + + + + Unshaded Area X x X x X X x x X x GLF = = = = = = = = = Btu/hr NE 0.0 18.2 48.0 27.2 1,305 N E 0.0 21.1 9.0 33.3 300 S 0.0 18.7 21.0 18.8 395 S 0.0 18.2 48.0 18.3 876 S 0.0 21.1 9.0 21.2 191 S 0.0 21.1 22.5 21.2 477 S 0.0X 18.7+ 21.0X 18.8= 395 Page Total 3 939 Internal Gain Btu/hr Occupants 4 Occupants X 230 Btuh/oCC. = 920 E ui ment Dwelling Units x 1 600 Btuh = 1,6001 Infiltration: 1.064 x 0.87 x 38.02 x 34 = 1191 Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10226 Latent Gain Btu/hr Occu ants Occupants' X 1 200 Btuh/oCC. = 800 Infiltration: 4,771 X. 0.87. X, 38.02 X 0.00263 = 413 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,213 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 36 of 36 .. � z - � ...i.� .. _ � - � Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _Zir_insk _Residence. Project Tie Total Conditioned Floor Area: 4,854 ft2 ❑NEw 9.9-A6 Zone 1 ❑flew 09 2 6 Zone 1 ❑ N.ew 01A8 Zone 2 ❑NEw 09 A6 Zone 2 ❑flew - _09-A6 Zone2 Ne, -99- 6 Zone 2 ❑ New �9-A6 Znne 2 ❑ NEw n9 -A6 Zone 2 ❑ New 01=A8 Zone 3 1-11New 9.9_A6 Zone_3 ❑ N.ew 99-A6 Zone 3 ❑ NEw _O A6 Zone 3 ❑New 9916 Zone 3 8/15/2007 Date _5.3148 Via Dnna-LgQuin.ta Existing Floor Area: n/a ft2 Building Front Orientation: (SW) 225 deg Project Address 0 ft2 Fuel Type: EJNew 09-A6 Zone 4 ❑ New 99-A6 Zon- 4 ❑ NEw 09-A6 7nnr 4 Building Permit # C_..M.._FnersConsultina 4,854 ft2 Fenestration: (760)449-1308 Plan Check/Date Documentation uthor 11.8 ft Area: Telephone Avg. U: 0.37 EnernvP_r_o 1.00 Ratio: CAClitnateZone-15 Field Check/Date Compliance Method 1 BUILDING ZONE Climate Zone TDV Standard Proposed Compliance Floor Area Volume _(kBtu/sf- r) Design Design Margin 1 80 -10,800 Space Heating 2.52 3.54 -1.02 1,104 _12..806 Space Cooling 66.42 62.10 4.32 2,070 24.899 Fans 9.46 9.06 0.39 699 _9_Q09 Domestic Hot Water 5.29 6.99 -1.70 Pumps 0.00 0.00 0.00 Totals 83.69 81.70 1.99 Percent better than Standard: 2.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Q Single Family ❑ Addition Total Conditioned Floor Area: 4,854 ft2 ❑NEw 9.9-A6 Zone 1 ❑flew 09 2 6 Zone 1 ❑ N.ew 01A8 Zone 2 ❑NEw 09 A6 Zone 2 ❑flew - _09-A6 Zone2 Ne, -99- 6 Zone 2 ❑ New �9-A6 Znne 2 ❑ NEw n9 -A6 Zone 2 ❑ New 01=A8 Zone 3 1-11New 9.9_A6 Zone_3 ❑ N.ew 99-A6 Zone 3 ❑ NEw _O A6 Zone 3 ❑New 9916 Zone 3 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (SW) 225 deg Raised Floor Area: 0 ft2 Fuel Type: EJNew 09-A6 Zone 4 ❑ New 99-A6 Zon- 4 ❑ NEw 09-A6 7nnr 4 Natural Gas Slab on Grade Area: 4,854 ft2 Fenestration: Average Ceiling Height: 11.8 ft Area: 1,574 ft 2 Avg. U: 0.37 Number of Dwelling Units: 1.00 Ratio: 32.4% Avg. SHGC: 0.33 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 13.V.ACti#1 1 80 -10,800 -0.22 Sleeping-- _SleepingStat- 2 ala HVAC #2 1,104 _12..806 ) 23_ Sleeping --StespmgSiaL ----j3La JiVAC #3 2,070 24.899 0.43 Living -I imgstat n/a 1iVAC 9 699 _9_Q09 _0.12 Liying Li_vij g -tat_ ---n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Root - Wall_ Wall - Wall_ Wall_ Wall_ Rao> - W311_ Wall wall Wall_ WalL- Roof_ Wal l Wall_ Wall_ Wall_ Wall_ Dno>- Wall_ Wall_ RanL- Wall_ Wall_ Wall Wood- x.,.080_ _0.026_ R_18 R-0 0_ 0_ 0 W_aod_ 120 _0.,0.69 -&21 R-0 () ----0----9.0 Wnod_ 439 xD&9 R-21 _R=0.9_ -99_ 9.0 Wood- 40 _0.-0.69_ _R-21-$=0 0 ----I8.0_ 99 i - ( � ❑flew _0]_A8 7nne 1 ❑ New- -0-9--A6- Zone 1 ❑ New 9.9-A6 Zone 1 ❑New _0.9-A6 Zone 1 Wnod 24 0069 R-21 R-0_22599 Wnod 93_ _0...0.69_ X21. --R-0-0---3-15----9.0 Wood- 1,104 _0.-026_ -R-38 _8=0 o_ _0_ 0 Wnnd 14n n n69 R-21 R -0 _n 0 90 Wnod X35_ 0069 R_21_B=0...O_-9.0 99 Wood 204 _0069 R-21 _R=0.0_ 180 99 `1X11 Wood_ 112 n _ 8 R-0 225 99 .9 21 0995-9.0 1Nnad- 313 o n69 R-21 R -n n 970---90 Wood_ _2_Q,7 0 026 x_38_ _R=Q...O_ 9 _0 Wood- 222 0.069 R_21 R-0 0 Q_ 9Q Wnod_ 255 _0._06.9_ -R-21 R-0 0 4590 IX MX 1X- [X- iX X X IN EX f[X [XII �I �I ❑NEw 9.9-A6 Zone 1 ❑flew 09 2 6 Zone 1 ❑ N.ew 01A8 Zone 2 ❑NEw 09 A6 Zone 2 ❑flew - _09-A6 Zone2 Ne, -99- 6 Zone 2 ❑ New �9-A6 Znne 2 ❑ NEw n9 -A6 Zone 2 ❑ New 01=A8 Zone 3 1-11New 9.9_A6 Zone_3 ❑ N.ew 99-A6 Zone 3 ❑ NEw _O A6 Zone 3 ❑New 9916 Zone 3 W_ ad- 199 _0..,0.69_ _R21 _R -Q0 _9.0 90 WDad_ 211 _0_069 -821 R-0 0 X35_ 9.0 Wnod_ 329 _0..069_ R-21 R-0 n 225 9 None 24 0600 Nnne g -n n 225 _90 Wood 170 0 069 R_21 R-0.0 270 gQ EJ New- 09 A6 Zone 3 ❑NEw 28_A5 ZnnE3 ❑New 09-A6 Zone 3 wood_ 519 _0.0.69 R-91 RAD _315 90❑ New 09 -Ar, Zone 3 El Raw- -01A8 Zone 4 W_ond_ 600_ _0026 R_38 R_0 0 0_ 0 Wood_ 0 0 069 R-21 R_0.0 x.599 L X -I [l [X- IXI EJNew 09-A6 Zone 4 ❑ New 99-A6 Zon- 4 ❑ NEw 09-A6 7nnr 4 Wnod_ 90 _0._0,6,9_ -R_91 -R=00_ _go _ () Wood- 70 0 069 X -91 R-0 0_ -135-99 Run Initiation Time: 08/15/07 07:22:36 Run Code: 1187187756 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:3 of 36 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _Ziunsk�8e.sidpin [ Single Family . ❑ Addition 8L1512097 Project Tie -53148 Via Desna—La_Quinia ❑ Existing + Add/Alt Building Front Orientation: Date Project Address 11.8 ft Natural Gas Building Permit # EaerConsuwrlq 1 (760) 449-1308 1,574 ft2 plan Check/Date Documentation uthor 32.4% Avg. Telephone BUILDING ZONE FnPLnvP_co (.A ClimateZonP 15 Field Check/Date Compliance Method Climate Zone ❑❑H TDV Standard Proposed Compliance kBtu/sf- r) Design Design Margin Space Heating 2.52 3.54 -1.02 Space Cooling 66.42 62.10 4.32 ❑❑ Fans 9.46 9.06 0.39 ❑❑ Domestic Hot Water 5.29 6.99 -1.70 ❑ Pumps 0.00 0.00 0.00 Totals 83.69 81.70 1.99 Percent better than Standard: 2.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [ Single Family . ❑ Addition n/a ft2 ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (SW) 225 deg Fuel Type: 11.8 ft Natural Gas Fenestration: Number of Stories: 1 Area: 1,574 ft2 Avg. U: 0.37 Ratio: 32.4% Avg. SHGC: 0.33 BUILDING ZONE INFORMATION Zone Name Floor Area Volume Total Conditioned Floor Area: 4,854 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 4,854 ft2 Average Ceiling Height: 11.8 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Thermostat Vent Units Zone Type Type Hgt. Area OPAQUE SURFACES Insulation -Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall— Wood_ M —0_0&2 _R-91 _R- 0 180_ 9Il Wall_ YV.ond— 294 _0_,06.2 —R21 _R -Oa 995-_9.0 Wall_ YVoDd_ 320- —0.98.2 _R_21 -JR-0-0- —315 90 IX X O ❑New 09=A6 7n P. 4 ❑ New 09-A6 Zone 4 El New 09-A6 7nne_4 ❑❑H ❑❑ FI ❑❑ ❑❑ ❑❑ ❑ r Run Initiation Time: 08/15/07 07:22:36 Run Code: 1187187756 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:4 of 36 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date FENESTRATION SURFACES Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 True Cond. Location/ # Type 3 Buq Screen 0.76 Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments Windori Left -(N-)- -360. --0-3BD NERC _O -3D -NERC 0_ _9D_ New 53 June 1 2 Window Rear (E) 36.0 0.350 NFRC 0_38 NFRC 90 90 New 54 Zone 1 3 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 55 Zone 1 4 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 56 Zone 1 5 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 57 Zone 1 6 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 58 Zone 1 7 Window Rear (E) 4.0 0.350 NFRC 0.38 NFRC 90 90 New 59 Zone 1 8 Window Front (SW) 6.0 0.380 NFRC 0_30 NFRC 225 90 New 90 Zone 1 -9- Window Left (NW) 48.0 0.39 NFRC 0.28 NERC 315 90 New 51 Zone 1 10 Window Left (NW) 9.0 0.350 NFRC 0_38 NFRC 315 90 New 52 Zone 1 11 Window Left (N) 6.0 0.350 NFRC 0_38 NFRC 0 90 New 84 Zone 2 12 Window Left (N) 15.0 0.380 NFRC 0_30 NFRC 0 90 New 77 Zone 2 1a Window Rear (E) 4.0 0.350 NFRC -0iB NFRQ -DQ 90 New 60 Zone 2 14 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 61 Zone 2 15 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC 90 90 New 62 Zone 2 16 Window Rear (E) 10.0 0.380 NFRC 0_30 NFRC 90 90 New 63 Zone 2 17 Window Rear (E) 10.0 0.350 NFRC 0_38 NFRC: 90 90 New 64 Zone 2 18 Window Rear (E) 10.0 0.380 NFRC 0_30 NFRC 90 90 New 65 Zone 2 1Q Window Rear (E) 4.0 0.35 NFRG 0.38 NFRQ90 90 New 66 Zone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Buq Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 10 Bug Screen 0.76 11 Buq Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 _ 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 72 None No Insulation 26-A1 New Zone 1 Slab Perimeter 149 None No Insulation 26-A1 New Zone 2 Slab Perimeter 185 None No Insulation 26-A1 New Zone 3 Slab Perimeter 93 None No Insulation 26-A1 New Zone 4 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:5 of 36 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 20. Window Rear (E) 40 035 NFRC' n 3s NFRC _92 -91 New 67 -Zone-2- one221 21 Window Rear (E) 4.0 0.350 NFRC 0.38 NFRC 90 90 New 68 Zone 2 22 Window Rear (E) 21.0 0.380 NFRC 0_30 NFRC 90 90 New 69 Zone 2 23 Window Front (SW) 15.0 0.380 NFRC 0.30 NFRC 225 90 New 70 Zone 2 24 Window Front (SW) 5.3 0.350 NFRC 0.38 NFRC 225 90 New 78 Zone 2 25 Window Front (SW) 15.0 0.380 NFRC 0_30 NFRC 225 90 New 71 Zone 2 2Q Window Front (SW) 5.3 0.350 NFRC 0.38 NFRC 225 90 New 79 Zone 2 27 Window Front (SW) 15.0 0.380 NFRC 0.30 NFRC 225 90 New 72 Zone 2 28 Window Front (SW) 5.3 0.350 NFRC 0.38 _NFRC 225 90 New 80 Zone 2 2R Window Front (W) 22.5 0.380 NFRC 0_30 NFRC- 270 90 New 73 Zone 2 30 Window Front (W) 6.0 0.350 NFRC 0_38 NFRC 270 90 New 81 Zone 2 31 Window Front (W) 48.0 0.390 NFRC 0_28 NFRC 270 90 New 74 Zone 2 32 _Window Front (W) 90 0.350 NFRC 0.38 NFRC 270 _90 New 75 Zone 2 33 Window Front (W) 6.0 0.350 NFRC 0_38 NFRC 270 90 New 82 Zone 2 34 Window Front (W) 6.0 0.350 NFRC 0_38 NFRC 270 90 New 83 Zone 2 35 Window Front (W) 2205 0.380 NFRC 0_30 NFRC 270 90 New 76 Zone 2 36 Window Front (W) 22.5 0.380 NFRC 0.30 NFR(: 270 90 New 85 Zone 2 37 Window Front (W) 22.5 0.380 NFRC 0.30 NFRC 270 90 New 87 Zone 2 38 Window Front (W) 46.2 0.380 NFRC 0.30 NFRC 270 90 New 89 Zone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen _ 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 00 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference- Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Lenqth R -Val. Location JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:6 of 36 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date FENESTRATION SURFACES # Type Area LI -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments _3S indowFront IWC_ -22 5_ _Q 3.8D r1FI3�_Q 30 S)FRC AZO_ -9Q New 88 7nne 2 40 Window Front (W) 22.5 0.380 NFRC 0.30 NFRC 270 90 New 86 Zone 2 41 Window Left (N) 91.0 0.350 NFRC 0.38 NFRC 0 90 New 32 Zone 3 42 Window Left (N) 4.0 0.350 NFRC 0.38 NFRC 0 90 New 37 Zone 3 43 Window Left (N) 4.0 0.350 NFRC 0_38 NFRC 0 90 New 38 Zone 3 44 Window Left (N) 4.0 0.350 NFRC 0.38 NFRC 0 90 New 39 Zone 3 A5 Window Left (N) 4.0 0.350 NFRC 0.38 NFRC 0 90 New 40 Zone 3 46 Window Rear (NE) 170.0 0.360 NFRC 0.32 NFRC 45 90 New 45 Zone 3 47 Window Rear (NE) 3.0 0.350 NFRC 0.38 NFRQ 45 90 New 46 Zone 3 4$ Window Rear (NE) 3.0 0.350 NFRC 0_38 NFRC 45 90 New 47 Zone 3 49 Window Rear (NE) 3.0 0.350 NFRC 0_38 NFRC 45 90 New 48 Zone 3 50 Window Rear (NE) 3.0 0.350 NFRC 0.38 NFRC 45 90 New 49 Zone 3 _5j_ Window Rear (NE) 3.0 0.350 NFRC 0.38 NFRC 45 90 New 50 Zone 3 52 Window Rear (E) 48.0 0.390 NFRC 0.28 NFRC 90 90 New 43 Zone 3 53 Window Rear (E) 9.0 0.350 NFRC 0.38 NFRC 90 90 New 44 Zone 3 54 Window Rear (E) 4.0 0.350 NFRC 0.38 NFRC 90 90 New 41 Zone 3 55 Window Rear (E) 4.0 0.350 NFRC 0_38 NFRC' 90 90 New 42 Zone 3 56- Window Right (SE) 110.0 0.360 NFRC 0.32 NFRC 135 90 New 10 Zone 3 5Z Window Right (SE) 3.0 0.350 NFRC 0.38 _NFRC 135 90_ New 11 Zone 3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # _ Exterior Shade Type SHGC Hgt. Wd. Len. HgL LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 _ 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Biu Screen _ 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen _ 0.76 52 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments I EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Paoe:7 of 36 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor" SHGCZ Azm. Tilt Stat. Glazinq Type Comments .5$ Window Right MF) 3.0 _0.3$NFRC NFRC-9_ _ _-135- New 12 Z 3 one 59 Window Right (SE) 3.0 0.350 NFRC 0.38 NFRC 135 90 New 13 Zone 3 60 Window Riaht (SE) 3.0 0.350 NFRC 0_38 NFRC 135 90 New 14 Zone 3 61 Window Front (SW) 30.0 0.350 NFRC 0.38 NFRC 225 90 New 91 Zone 3 62 Window Front (SW) 60.0 0.390 NFRC 0_28 NFRC 225 90 New 1 Zone 3 63 Window Front (SW) 4.3 0.350 NFRC 0_38 NFRC 225 90 New 2 Zone 3 64 Window Front (,SW) 4.3 0.350 NFRC 0.38 NFRC 225 90 New 3 Zone 3 65 Window Front (SW) 4.3 0.350 NFRC 0.38 NFRC 225 90 New 4 Zone 3 -K Window Front (SW) 4.3 0.350 NFRC 0.38 NFRC 225 90 New 5 Zone 3 67 Window Front (SW) 76.0 0.360 NFRC 0_32 NFRC 225 90 New 6 Zone 3 68 Window Front (SW) 3.0 0.350 NFRC 0_38 NFRC 225 90 New 7 Zone 3 69 Window Front (SW) 3.0 0.350 NFRC 0_38 NFRC 225 90 New 8 Zone 3 7Q Window Front (SW) 3.0 0.35 NFRC 0.38 NFRC 225 _g_Q New 9 Zone 3 71 Window Front (W) 64.5 0.350 NFRC 0_38 NFRC 270 90 New 31 Zone 3 72 Window Front (W) 4.0 0.350 NFRC 0_38 NFRC 270 90 New 33 Zone 3 73 Window Front (W) 4.0 0.350 NFRC 0_38 NFRC 270 90 New 34 Zone 3 74 Window Front (W) 4.0 0.350 NFRC 0_38 NFRC: 270 90 New 35 Zone 3 75 Window Front (W) 4.0 0.350 NFRC 0_38 NFRC 270 90 New 36 Zone 3 Window Left (NW) 32.0 0.350 NFRC 0.38 NFRC 315 90 New 22 Zone 3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen 0.76 59 Biu Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen _ 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen _ 0.76 71 Bug Screen 0.76 72 Bug Screen _ 0.76 73 Bug Screen _ 0.76 74 Bug Screen _ 0.76 75 Bug Screen 0.76 76 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments I EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Pace:8 of 36 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 1Z nndawIeft_(N1 JR 0_ _0.350_NERC._0.3B NERC 315 _9.0_ New 23 Zone 78 Window Left (NW) 4.0 0.350 NFRC 0.38 NFRC 315 90 New 24 Zone 3 79 Window Left (NW) 4.0 0.350 NFRC 0_38 NFRC 315 90 New 25 Zone 3 80 Window Left (NW) 4.0 0.350 NFRC 0.38 NFRC 315 90 New 26 Zone 3 81 Window Left (NW) 3.5 0.350 NFRC 0_38 NFRC 315 90 New 27 Zone 3 82 Window Left (NW) 3.5 0.350 NFRC 0_38 NFRC 315 90 New 28 Zone 3 Aa Window Left (NW) 3.5 0.350 NFRC 0.38 NFRC 315 90 New 29 Zone 3 84 Window Left (NW) 3.5 0.350 NFRC 0.38 NFRC 315 90 New 30 Zone 3 -K Window Rear (NE) 48.0 0.390 NFRC 0.28 NFRC 45 90 New 15 Zone 4 $B Window Rear (NE) 9.0 0.350 NFRC 0_38 NFRC 45 90 New 16 Zone 4 87 Window Right (S) 21.0 0.380 NFRC 0_30 NFRC 180 90 New 17 Zone 4 88 Window Right (S) 48.0 0.390 NFRC 0_28 NFRC 180 90 New 19 Zone 4 BR Window Right (S) 9.0 0.350 NFRC 0.38 NFRC 180 90 New 20 Zone 4 90 Window Right (S)- 22.5 0.350 NFRC 0_38 NFRC 180 90 New 21 Zone 4 91 Window Right (S) 21.0 0.380 NFRC 0_30 NFRC 180 90 New 18 Zone 4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 77 Bug Screen 0.76 78 Bug Screen 0.76 79 Bug Screen 0.76 80 Bug Screen 0.76 81 Bug Screen 0.76 82 Bug Screen 0.76 83 Bug Screen 0.76 84 Bug Screen 0.76 85 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 86 Bug Screen 0.76 87 Bug Screen 0.76 88 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 89 Bug Screen 0.76 90 Bug Screen 0.76 91 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (so (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Type Length R -Val. Insulation Location JA IV Reference Condition Status Location/ Comments EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Paoe:9 of 36 1 ZEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct.design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an.approved HERS rater. Designer or Owner (per Busine s & Professions Code) ` Documentation Author Name: QA1t(Name: Micah Combs Title/Firm: AA Group Title/Firm: C.M. Energy Consulting Address: 20341 Sw Birch St #320 Address: P.9A Box 4655 Newport Beach, CA 92660 Pa D e CA 9t261 T phone: 9- 10-19pg Lic. #: Telepho e: 7 9- 01 S•Z�•o7 (signature) (date) (signatur) (date Enforcement Agency Name' Title/Firm: �, y Address: Telephone: Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC #2 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC #3 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling • Location R -Value Status Tested? HVAC #1 Ducted Ducted Attic 6.0 New Yes HVAC #2 Ducted Ducted Attic 6.0 New Yes HVAC #3 Ducted . Ducted. Attic 6.0 New Yes Hydronic Piping Pipe Pipe InsuL System Name Length Diameter " Thick. WATER HEATING SYSTEMS Rated •Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 2 40,000 50 New 0.58 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insulation ZEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct.design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an.approved HERS rater. Designer or Owner (per Busine s & Professions Code) ` Documentation Author Name: QA1t(Name: Micah Combs Title/Firm: AA Group Title/Firm: C.M. Energy Consulting Address: 20341 Sw Birch St #320 Address: P.9A Box 4655 Newport Beach, CA 92660 Pa D e CA 9t261 T phone: 9- 10-19pg Lic. #: Telepho e: 7 9- 01 S•Z�•o7 (signature) (date) (signatur) (date Enforcement Agency Name' Title/Firm: �, y Address: Telephone: Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date HVAC SYSTEMS Location Heating Type Minimum Eff Cooling Type Minimum Condition Eff Status Thermostat Type HVAC #4 Central Furnace 92% AFUE Split Air Conditioner 15.5 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling Duct Locations Duct Condition R -Value Status Ducts Tested? HVAC #4 Ducted Ducted Attic 6.0 New Yes Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control #. HP Type In Plenum Outside Buried Insulation tEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (p r Bus ess & Professions Code) Documentation Author Name: Q�Ip �, Name: Micah Combs Title/Firm: AA Group Title/Firm: C.M. Energy Consulting Address: 20341 Sw Birch St #320 Address: ho. B^ 465 Newport ach CA 92660 I De eKdAA2261 T lephone- 94Q- 50- 09 Lic. #: Tel hone: V6&44,4 13 (signature) (date) (sign lure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Zirinsky Residence 8/15/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justiticatton and documentation submitted. Plan I Field. The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The HVAC System "HVAC #1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC #2" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC #3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC #4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 12 of 36 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A 11 DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 9 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value:_____. ❑ ❑ ❑ +§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ Q ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ Q ❑ b. outside air intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed. ❑ Q ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ Q ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rale no greater than 2.0 perm/inch. ❑ 0 ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El 0 El Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 1:1 0 ❑ Coefficient (SHGC), and infiltration certification. ' 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ y § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated _with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external' ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water lank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. ' 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 13 of 36 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands: 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑K ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑x ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ , ❑x ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance healing and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ X❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑x ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table' ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfiedto comply with Section 119(d).. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑x ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 14 of 36 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY - PROJECT NAME DATE Zirinsky Residence 8/15/2007 SYSTEM NAME FLOOR AREA HVAC #1 1,080 Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 50.9 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sqft) 33.3 Total Output (sgft/Ton) 360.0 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.11 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfmisgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 496 12,138 1,544 303 11,298 26.0 OF 69.3 OF 0 105.0 OF 1,102 900 0 0 0 0 011 0 0 0 104.3 of 0 1,102 900 14,342 1,544 13,098 HVAC EQUIPMENT SELECTION MAYTAG PSA46F / PGC1 RC (3 Ton) 31,113 0 55,000 Total Adjusted System Output 31,113 0 55,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.3 OF 105.0 OF 105.0 OF Air Ducts Outside Air OSupply 0 cfm 104.3 of Heating Coil Supply Fan 1200 cfm ROOMS 70.0 OF 6 9.3 of Return Air Ducts ` I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 78.9 / 63.0 of 55.0 53.7 of 55.0 / 53.7 of O4 Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 55.9 / 54.1 of 1200 cfm ' ROOMS 42.5% R.H. 78.0/62.6OF 78.9/62.90F Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:15 of 36 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zirinsky Residence 8/15/2007 SYSTEM NAME FLOOR AREA HVAC #2 1,104 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1209 22,848 1,56 L368 19,642 0 2,074 1,564 0 0 0 0 011 0 0 0 0 2,074 1,564 26,996 1,56 22,771 MAYTAG PSA4BF / PGC1 RC (5 Ton) 49,459 0 110,000 Total Adjusted System Outputa9,a59 0 110,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm F Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.3 OF 7 ' 120.9 OF 120.9 OF Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 120.2 OF 2000 cfm ROOMS 69.3 OF 70.0 OF Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolinq Peak) I 11.0 / 77.6 OF 79.0/63.20 F l 55.7/54.40F 55.7 / 54.4 OF Outside Air 0 cfm Cooling Coil 79.0/63.2 OF Supply A Ducts Supply Fan 56.7 / 54.8 of 2000 cfm 43.1% R.H. ROOMS 78.0 ! 62.9 OF Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 16 of 36 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zirinsky Residence 8/15/2007 SYSTEM NAME . FLOOR AREA HVAC #3 2,070 ENGINEERING CHECKS IFSYSTEM LOAD Number of Systems 2 Heating System Output per System 110,000 Total Output (Btuh) 220,000 Output (Btuh/sqft) _ 106.3 Cooling System Output per System 57,000 Total Output (Btuh) 114,000 Total Output (Tons) 9.5 Total Output (Btuh/sqft) 55.1 Total Output (sgft/Ton) 217.9 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sqft) 1.93 Airflow (cfmrron) 421.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0 of 69.4 of r Outside Air 0 cfm 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM- LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,542 37,744 2,226 904 33,665 0 3,427 2,681 0 0 0 0 011 0 0 0 0 3,427 2,681 44,598 2,226 39,028 HVAC EQUIPMENT SELECTION MAYTAG PSA48FI PGC 1RC (5 Ton) 98,096 0 Total Adjusted System Output (Adjusted for Peak Design Conditions) 98,096 0 TIME OF SYSTEM PEAK Aug 2 pm rstream Temper 105.0 of Heating Coil 220,000 220,000 Jan 12 am 105.0 of Q� Supply Air Ducts Supply Fan . 104.4 of 4000 cfm ROOMS 70.0 of Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peakl I 111.0 / 77.6 of 78.8 / 62.7 of . 55.0 / 53.7 of 55.0 / 53.7 of Outside Air 0 cfm Cooling Coil 78.8 / 62.7 of O Supply Air Ducts Supply Fan 55.8 / 54.0 of 4000 cfm 41.7% R.H. ROOMS 78.0 / 62.4 of Return Air Ducts E I EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page:17 of 36 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zirinsky Residence 8/15/2007 SYSTEM NAME FLOOR AREA HVAC #4 600 ENGINEERING CHECKS IFSYSTEM LOAD Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuhlsgft) 58.3 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuhlsgft) 40.0 Total Output (sgftrron) 300:0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.33 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions PSYCHRO 26.0 of Outside �� 0 cfm 68.9 of 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 418 10,226 1,213 302 11,233 0 928 895 0 0 0 0 0 0 0 0 0 928 895 12,083 1,213 13,022 MAYTAG PSA413F / PGCIRC (2 Ton) 20,790 0 35,000 Total Adjusted System Output 20,790 0 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm IF Jan 12 am ream Temperatures at Time of Heating Peak) 105.0 of 105.0 of O Supply Air Ducts Heating Coil Supply Fan 103.9 of 800 cfm ROOMS 70.0 of Return Air Ducts `S COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0 / 77.6 of 79.1 ! 63.1 of 55.0 / 53.7 of • 55.0 ! 53.7 of O4 S Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan - 56.1 / 54.1 of soo cfm 42.7% R.H. ROOMS 79.1/63.1 of 78.0 ( 62.7 of < 10Return Air Ducts I EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Paae:18 of 36 ROOM LOAD SUMMARY PROJECT NAME Zirinsky Residence DATE 8/15/2007 SYSTEM NAME HVAC #1 FLOOR AREA 1,080 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Master Bedroom/His Closet 1 496 12,138 1,544 496 12,138 1,544 303 11,298 y PAGE TOTAL 1 496 12,138 1,544 303 11,298 TOTAL 496 12,138 1,544 303 11,298 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 19 of 36 ROOM LOAD SUMMARY PROJECT NAME Zirinsky Residence DATE 8/15/2007 SYSTEM NAME HVAC #2 FLOOR AREA 1,104 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Master Bath/Her Closet 1 1,009 22,848 1,561 1,009 22,848 1.561 368 19,642 r PAGE TOTAL 1 1,009 22,8x8 1,561 368 19,642 TOTAL 1 1,009 22,848 1,561 368 19,642 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 20 of 36 PROJECT NAME Zirinsky Residence DATE 8/15/2007 SYSTEM NAME HVAC #3 FLOOR AREA 2,070 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT' CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Living 1 1,542 37,744 2,226 1,542 37,744 2,226 904 33,665 PAGE TOTAL 1 1,542 37,744 2,226 904 33,665 TOTAL 1 1,542 37,744 2,226 904 33,665 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 21 of 36 t ROOM LOAD SUMMARY PROJECT NAME Zirinsky Residence DATE 8/15/2007 SYSTEM NAME HVAC #4 FLOOR AREA 600 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 4 Game Room 1 418 10,226 1,213 418 10,226 1,213 302 11,233 PAGE TOTAL 418 10,226 1,213 302 11,233 ' TOTAL 1 418 10,226 1,213 302 11,233 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 22 of 36 ROOM HEATING PEAK LOADS Project Title Date Zirinskv Residence 18/15/2007 Room Information Desicin Conditions Room Name Master Bedroom/His Time of Peak Jan 12 am Floor Area 911,0 o Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 760F, Conduction Area U -Value ZT of Btu/hr x x x x x x x x x x x x X x x X x x x x x x x x x x x x. x x. x x x x x x x x x 0.0260 x x X x x X x X x X x X x X x x x x: x x x x x x x x x x x x x x x x x x x x 44 = = = = = = = = = = = = = = = _ = = = = = = = = = = = = = = = = = = = _ 1.236 0.7300 44 2,313 0.0690 44 364 0.3800 44 602 0.0690 44 1,333 0.3500 44 554 0.3500 44 62 0.3500 44 62 0,3500 44 62 0.3500 44 62 0.3500 44= 6 0.0690 44 121 0.0690 44 73 0.3800 44= 100 0.0690 44 28 0.3900 44 824 - 0.3.40 9 Items shown with an asterisk O denote conduction through an interior surface to another room. Page Total: 8,249 Infiltration: 'Schedule x 1.064 x 1 080 x 10.00 x 0.362 16] x 44 = 3 050 Schedule Air Sensible Area Ceiling Height ACH AT Fraction 'TOTAL HOURLY HEAT LOSS FOR ROOM 11,298 El EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page:23 of 36 ROOM HEATING PEAK LOADS Project Title Date Zirinskv Residence 8/15/2007 l oom Information Desi n Conditions oom Name Master Bath/Her Time of Peak Jan 12 am Floor Area _ 91',010a Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value QT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 525 Infiltration: 1.00 x 1.064 X 1 104 x Heigh x 0.312 / 6] X 44 = 3 117 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,642 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 24 of 36 1104.0 x x x X x X x X x X x x x x X x x x x x x x x X x x X x X X x x x x x X x X X 0.0260 X x x X x x X x X X x x x X x x x x x x x x x X X x X x X X X x X x x x X x X 44 = = = = = = = = = = =15 = = = = = =339 = = = = =82 =--------- = = = =376 = = = = = = = 1,263 perimeter = 149.0 0.7300 44 4,786 140.5 0.0690 44 427 6.0 0.3500 44 92 15.0 0.3800 44 251 435.0 0.0690 44 1,321 4.0 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44 62 10.0 0.3800 44 167 10.0 0.3500 4 10.0 0.3800 44 167 4.0 0.3500 44 62 4.0 0.3500 44 62 4. 0.3500 4 21.0 0.3800 44 351 204-5 44 62J 111.6 0.0690 44 15.0 0.3800 44 251 5.3 0.3500 44 82 15.0 0.3800 44 25] 5.3 0.3500 44 82 15.0 0.3800 44 251 5.3 0.3500 44 312.8 0.0690 44 95 22.5 0.3800 44 376 6.0 0.3500 44 92 48.0 990 44=894 () 03500 4-4 0.3500 44=92 6.0 0.3500 44=92 22.5 0.3800 44 22.5 0.3800 44 376 22.5 0.3800 44 376 46.2 0.3800 44 773 22.5 0.3800 44 376 22.5 0.3800 44 376 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 525 Infiltration: 1.00 x 1.064 X 1 104 x Heigh x 0.312 / 6] X 44 = 3 117 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,642 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 24 of 36 ROOM HEATING PEAK LOADS Project Title Date Zirinsk Residence 8/15/2007 Room Information Design Conditions Room Name Living Time of Peak Jan 12 am Floor Area 2,070 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value ,,LT OF Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 23,834 Infiltration: [ 1.001 x 1.064 x 2 070 x 12.00 x 0.302 / 60] x 44 = 5 845 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,665 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 25 of 36 2,070.0 X x x x x x X X X x x X x x x X x x X x x X x x X x X x x X x x X X x X X x X 0.0260 X x x X x X X X X x x-4 X x X x x x x X x x X x x X x X x x x X X X X x x X X X 44 = = = = = = = = = = =46 = = = = = = = = = = =1 =66 = = = = = = = 2,368 perimeter = 185.0 0.7300 44 5,942 221.5 0.0690 44 672 91.0 0.3500 44 1,401 4.0 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44 62 255.0 0.0690 44 774 170.0 0.3600 44 2,693 3.0 0.3500 3.0 0.3500 44 46 3.0 0.3500 44 46 3.0 0.3500 4 46 3.0 0.3500 44=46 199.0 0.0690 44 604 9_ 0,3900 44=824 9.0 0.3500 44 139 4.0 0.3500 44 62 4.0 0.3500 44 62 211.0 0,0690 44=641 110.0 0.3600 44 1,742 3.0 0.3500 44 46 3.0 0.3500 44 4 3.0 0.3500 44=46. 3.0 0.3500 44 46 329.3 0.0690 44 1,000 30.0 0,3500 44=462 n -O_ 0 MOO 030 4.3 0.3500 4.3 0.3500 44=66 4.3 0.3500 44 4.3 0.3500 44 66 76.0 0.3600 44 1,204 3.0 0.3500 44 46 3.0 0.3500 44 46 3.0 0.3500 44 46 24.0 0.6000 44 634 170.0 0.0690 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 23,834 Infiltration: [ 1.001 x 1.064 x 2 070 x 12.00 x 0.302 / 60] x 44 = 5 845 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,665 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 25 of 36 ROOM HEATING PEAK LOADS Project Title Date Zirinsk Residence 8/15/2007 Room Information Desi n Conditions Room Name Living Time of Peak. Jan 12 am Floor Area 2,070 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature a 70°F 64.5 x X X X x. X X X x x x X x X x. x X x xa x xx x x X, X. x x x. X x X. x X. x _ x x .X x ".X 0.3500 X X x X X x x x x x X X X x x x x x x x x x X x x xi x X x X x x X x x x X x 44 = = = = = = = = = = = = = = = - = = = - _ = - - - - - - - - = - - - - - 993 4.0 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44 62 519.0 0.0690 44 1,576 32.0 0.3500 44 493 18.0 0.3500 44 277 4 0.3500 44 62 4.0 0.3500 44 62 4.0 0.3500 44=62 3.5 0.3500 44 54 3.5 0.3500 44 54 3.5 0.3500 44 54 3.5 0.3500 44p J _, e Items shown with an asterisk(Ledule ') denote conduction through an interior surface to another room. Page Total: 3,9861 Infiltration;1.00 x 1.064 x 2070 x 12.00 x 0.302 /6] x 44 = 5845 • Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,665 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 26 of 36 i': ROOM HEATING PEAK LOADS Project Title Date Zirinsk Residence 8/15/2007 Room Information Design Conditions Room Name Game Room Time of Peak Jan 12 am Floor Area 600 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Items shown with an asterisk (•Ledule ) denote conduction through an interior surface to another room. • Page Total: 9,5391 Infiltratiorr1.00 x 1.064 x 600 x 15.00 x 0.241 / 6] x 44 = 1 694 Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,233 EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page: 27 of 36 I Area x x x x x x x x x x x x x x x x x x x x. x x x x.. X, x x x x x x x x x x x x x x U -Value x x x x x x x x x x x x x x x x x x x x x x x x x x x x x �X x x x x x x x x x pT of = = = = = = = = = = = Y = = = _ = = - = - - = = = _ = - = = - = — - = — - = Btu/hr 600.0 0.0260 44 686 perimeter = 93.0 0.7300 44 2,987 48.0 0.3900 44 824 9.0 0.3500 44 139 90.0 0.0690 44 273 70.0 0.0690 44 213 178.5 0.0690 44 542 21.0 0.3800 44 351 + 48.0 0,3900 44 824 9.0 0.3500 44 139 22.5 0.3500 44= 21.0 0.3800 44 351 294.0 0.0690 44 893 320.0 0.0690 44 972 _ Items shown with an asterisk (•Ledule ) denote conduction through an interior surface to another room. • Page Total: 9,5391 Infiltratiorr1.00 x 1.064 x 600 x 15.00 x 0.241 / 6] x 44 = 1 694 Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,233 EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page: 27 of 36 I RESIDENTIAL ROOM COOLING LOAD SUMMARY --JProject Title Date Zirinsk Residence 8/15/2007 Room Information Desi n Conditions Room Name: Master Bedroom/His Closet Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,080 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 780F Outdoor Daily Range: 340F ue zourraces R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.161 IR -21 Wall (W.21.2x6.161 I Orientation Area x X X X X X X x x x x X U -Factor X X X X X x X X x x x x CLTD 1 = = = = = = = = = = = = N 1,080.0 0.0180 56.0 N 120.0 0.0690 23.0 E 439.0 0.0690 33.0 S 40.0 0.0690 26.0 SW 24.0 0.0690 31.0 NW 93.0 0.0690 30.2 21.1 4.0 43.7 175 E 0.0X 21.1+ 4.0X 43.7= 175 E 0.0x 21.1+ 4.0X 43.7= 175 E 0.0x 21.1+ 4.0X 43.7= 175 SW 0.0x 18.7+ 6.0X 25.6= P T t Items shown with an asterisk (') denote conduction through an interior surface to another room. age O a 1. Cooling Load Temperature Difference (CLTD) Fenestration Vertical Slider 53 Fxd Wdw 54 Fxd Wdw, 55 Fxd Wdw 56 Fxd Wdw 57 Fxd Wdw 58 Fxd Wdw 59 Vertical Slider 90 Frnch Dr 51 Fxd Wdw 52 Btu/hr 1,088 190 1,000 72 51 194 2 596 Orientation Btu/hr Shaded Area X X X X X x GLF + + + + + + Unshaded Area X X X X X X GLF = = = = = = Btu/hr N 0.0 18.7 36.0 18.7 674 E 0.0 21.1 36.0 43.7 1,572 E 0.0 21.1 4.0 43.7 175 E 0.0 21.1 4.0 43.7 175 E 0.0X 21.1+ 4.0X 43.7= 175 E 0.0x 21.1+ 4.0X 43.7= 175 E 0.0x 21.1+ 4.0X 43.7= 175 SW 0.0x 18.7+ 6.0X 25.6= 154 NW 0.0 18.2 48.0 27. 1,305 NW 0.0x 21.1+ 9.0x 33.3= 300 Page Total i 4,878 Internal Gain . Btu/hr Occupants B4 Occupants X 230 Btuh/occ. = 920 E ui ment 1 Dwelling Units X 1,600 Btuh 1 1,6001 Infiltration: 1.064 X 0.87 x 68.43 X 34 = 2144 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,138 Latent Gain Btu/hr Occu ants F-41 Occupants x 200 Btuh/occ. _, 800 Infiltration: 4,77 x 0.87 x 68.x3 x 0.00263 = 744 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,544 EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page: 28 of 36 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsk Residence 8/15/2007 Room Information Desi n Conditions Room Name: Master Bath/Her Closet Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,104 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation I Area U -Factor CLTD 1 N 1,104.0 X X X X X X X x x X x x 0.0180 X X X X X X X x X X X X 56.0 = = = = = = = = = = = N 140.5 0.0690 23.0 E 435.0 0.0690 33.0 S 204.5 0.0690 26.0 (SW), 111.6 0.0690 31.0 W 312.8 0.0690 33.0 4.0x 43.7= 175 E 0.0x 21.1+ 4.0x 43.7= 175 E 0.0X 21.1+ 4.0 43.7 175 E 0.0X 18.7 10.0X 36.5= 365 E 0.0 21.1 Items shown with an asterisk (') denote conduction through an interior surface to another room.. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 84 Vertical Slider 77 Fxd Wdw 60 Fxd Wdw 61 Fxd Wdw 62 Csmnt Wdw 63 Fxd Wdw 64 Csmnt Wdw 65 Fxd Wdw 66 Fxd Wdw 67 Btu/hr 1,113 223 990 367 239 712 3 644 Orientation Btu/hr Shaded Area x X x GLF + + + + + Unshaded Area X X X X X Page GLF = = = = = Btu/hr 22 848 N 0.0x 21.1+ 6.0x 21.1= 127 N 0.0 18.7 15.0 18.7 281 E 0.0x 21.1+ 4.0x 43.7= 175 E 0.0x 21.1+ 4.0x 43.7= 175 E 0.0X 21.1+ 4.0 43.7 175 E 0.0X 18.7 10.0X 36.5= 365 E 0.0 21.1 10.0 43.7 437 E -0.0x 18.7 10.0x 36.5= 365 E 0.0X 21.1+ 4.0X 43.7= 175 E 0.0X 21.1+ 4.0 43.7 175 Total 2 aa8 Internal Gain Btu/hr Occupants x 230 Btuh/occ; Occupants F1, 920 E ui menl Dwelling Units X 1,600 Btuh _ 1 600 Infiltration: 1.064 x 0.87 x 69.95 x 34 = 2192 Air Sensible CFM ELA In'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22 848 Latent Gain Btu/hr 11 Occupants F4 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,77 x 0.87 x 69.95 x 0.00263 = 761 Air Latent CFM ELA pW ' TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,561 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 29 of 36 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsky Residence 8/15/2007 Room Information Design Conditions Room Name: Master Bath/Her Closet Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,104 sf Outdoor Web Bulb Temperature: 780 Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Orientation Area U -Factor CLTD ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Coolinq Load Temperature Difference (CLTD) Fenestration Fxd Wdw 68 Vertical Slider 69 Vertical Slider 70 Fxd Wdw 78 Vertical Slider 71 Fxd Wdw 79 Vertical Slider 72 Fxd Wdw 80 Vertical Slider 73 Fxd Wdw 81 Btu/hr Orientation Btu/hr X X X x GLF x Unshaded Area = GLF = = = x E ' 0.0X x 4.0x = 175 E X 18.7+ 21.0X x 767 = 0.0x 18.7+ x 25.6= 385 x 0.0X = 5.3x 29.8= x SW 0.0 x 15.0 = 385 SW x 21.1+ 5.3X x 158 = 0.0 18.7 x 25.6 385 x 0.0x 21.1+ 5.3X 29.8= x W 0.0x,: x 22.5X = 822 W xx 21.1+ 6.0x 43.7= 262 = x x. Total x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Coolinq Load Temperature Difference (CLTD) Fenestration Fxd Wdw 68 Vertical Slider 69 Vertical Slider 70 Fxd Wdw 78 Vertical Slider 71 Fxd Wdw 79 Vertical Slider 72 Fxd Wdw 80 Vertical Slider 73 Fxd Wdw 81 Btu/hr Orientation Btu/hr Shaded Area X X x GLF + + + Unshaded Area X X x Page GLF = = = Btu/hr E ' 0.0X 21.1+ 4.0x 43.7= 175 E 0.0X 18.7+ 21.0X 36.5= 767 SW 0.0x 18.7+ 15.0X 25.6= 385 SW 0.0X -21.1+ 5.3x 29.8= 158 SW 0.0 18.7 15.0 25.6 385 SW 0.0x 21.1+ 5.3X 29.8= 158 SW 0.0 18.7 15.0 25.6 385 SW 0.0x 21.1+ 5.3X 29.8= 158 W 0.0x,: 18.7+ 22.5X 36.E 822 W 0.0x 21.1+ 6.0x 43.7= 262 Total 3 sss Internal Gain Btu/hr Occupants 4 Occupants X " 230 Btuh/occ. - = 920 E ui ment Dwelling Units x 1.600 Btuh 1 1,6001 Infiltration: 1.064 x 0.87 x 69.95 x _ 2192 Air Sensible CFM . ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,848 Latent Gain Btu/hr Occupants F 41 Occupants x - 200 Btuh/occ. = 800 Infiltration: 4,771 x r 0.87 X 69.95 x ' 0.00263 _ 761 Air Latent CFM ELA "Lw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,561 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 30 of 36 s RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinskv Residence 18/15/2007 Room Information Design Conditions Room Name: Master Bath/Her Closet Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,104 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = xx = x x = P T t l Items shown with an asterisk (') denote conduction through an interior surface to another room. age O a 1. Cooling Load Temperature Difference (CLTD) Fenestration Frnch Dr 74 Fxd Wdw 75 Fxd Wdw 82 Fxd Wdw 83 Vertical Slider 76 Vertical Slider 85 Vertical Slider 87 Vertical Slider 89 Vertical Slider 88 Vertical Slider 86 Btu/hr 0 Orientation Shaded Area X x X X x X x x X GLF + + + + + + + + + Unshaded Area X x x x x X x x x GLF = = = = = = = = = Btu/hr W 0.0 18.2 48.0 34.8 1,67 W 0.0 21.1 9.0 43.7 393 W 0.0X 21.1+ 6.0x 143.7= 262 W 0.0X 21.1+ 6.0x 43.7= 262 W 0.0 18.7 22.5 36.5 822 W 0.0 18.7 22.5 36.5 822 W 0.0 18.7 22.5 36.5 822 W 0.0 - 18.7 46.2 36.5 1,690 W 0.0 18.7 22.5 36. 822 W 0.0 18.7 22.5 36.5 822 Internal Gain Occupants F�l Occupants X 230 Btuh/occ. E_ ui ment Dwelling Units x 1 600 Btuh' _ Page Total 8 389 Btu/hr 920 1,600 Infiltration: 1.064 x 0.87 x 69.95 x 34 = 2192 Air Sensible CFM ELA le�kT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22 848 Latent Gain Occu ants Occupants X I Btuh/occ. _ Btu/hr 800 Infiltration: 4,771 x 0.87 x F 69.95 x 0.00263. = 761 Air Latent CFM ELA pW " TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,561 EnergyPro 4.3 by EnergySofl - User Number: 1086 Job Number: Page: 31 of 36 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsky Residence 8/15/2007 Room Information Design Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,070 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Orientation Area X X X X X X X X X x X x U -Factor X X X X X x X x X x x X CLTD 1 = = = = = = = = = = = N 2,070.01 0.0180 56.0 N 221.5 0.0690 23.0 NE 255.0 0.0690 29.0 E 199.0 0.0690 33.0 SE 211.0 0.0690 31.0 SW 329.3 0.0690 31.0 (SW) 24.0 0.6000 31.0 (W) 170.0 0.0690 33.0 (NW) 519.0 0.0690 30.2 0.0 19.1 170.0 29.4 4,992 NE 0.0X 21.1+ 3.0X 33.3= 100 NE Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 32 Fxd Wdw 37 Fxd Wdw 38 Fxd Wdw 39 Fxd Wdw 40 Pocket Siding GIs Dr 45 Fxd Wdw 46 Fxd Wdw 47 Fxd Wdw 48 Fxd Wdw 49 Btu/hr Orientation i Shaded Area ` X x X GLF + + + Unshaded Area X X X X X X Page GLF = = _ Btu/hr, 4109 N 0.0X 21.1+ 91.0 21.1= 1,920 N 0.0x 21.1+ 4.0 21.1= 84 N 0.0x 21.1+ 4.0x 21.1= 84 N 0.0X 21.1+ 4.0 21.1= 84 N 0.0 '21.1 4.0 21.1 84 NE 0.0 19.1 170.0 29.4 4,992 NE 0.0X 21.1+ 3.0X 33.3= 100 NE 0.0X 21.1+ 3.0x 33.3= 100 NE 0.0x 21.1+ 3.0X 33.3 100 NE 0.0x 21.1+ 3.0x 33.3= 100 Total 7 s5o Internal Gain Btu/hr Occupants F�, Occupants x 230 Btuh/occ. 920 E ui ment Dwelling Units X 1,6001 Btuh _ 1 600 Infiltration: 1.064 X 0.87 X 131.16 X 34 = 4109 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,744 Latent Gain Btu/hr Occu ants Occupants X 200 Btuh/DCC. F 800 Infiltration: 4 77 x 0.87 x 131.16 x 0.00263 = 1 426 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 226 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 32 of 36 s RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsk Residence 18/15/2007 Room Information Design Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,070 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Orientation Area U -Factor CLTD 1 Items shown with amasterisk (•) denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 50 Frnch Dr 43 Fxd Wdw 44 Fxd Wdw 41 Fxd Wdw 42 Pocket Sldnq GIs Dr 10 Fxd Wdw 11 Fxd Wdw 12 Fxd Wdw 13 Fxd Wdw 14 Btu/hr Orientation ? x x x x x x x x x x x x X x x x x x x x x x x x x x x + + + + = = = = = _ = = = = = = X X x Page GLF = = = = = = Btu/hr 4109 O.Ox 21.1+ 3.0X 33.3 100 HNEEE] E 0.0X 18.2 48.0X 34.8= 1671 E 0.0x 21.1+ 9.0x 43.7 393 E 0.0x 21.1+ 4.0x 43.7 175 E 0.0 21.1 4.0 43.7 175 SE 0.0 19.1 110.0 26.4 2,908 Items shown with amasterisk (•) denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 50 Frnch Dr 43 Fxd Wdw 44 Fxd Wdw 41 Fxd Wdw 42 Pocket Sldnq GIs Dr 10 Fxd Wdw 11 Fxd Wdw 12 Fxd Wdw 13 Fxd Wdw 14 Btu/hr Orientation ? Shaded Area X x x GLF + + + + Unshaded Area X X x Page GLF = = = = = = Btu/hr 4109 O.Ox 21.1+ 3.0X 33.3 100 HNEEE] E 0.0X 18.2 48.0X 34.8= 1671 E 0.0x 21.1+ 9.0x 43.7 393 E 0.0x 21.1+ 4.0x 43.7 175 E 0.0 21.1 4.0 43.7 175 SE 0.0 19.1 110.0 26.4 2,908 SE, 0.0X 21.1+ 3.0X 29.8= 90 SE 0.0x 21.1+ 3.0X 29.8- 90 SE 0.0x 21.1+ 3.0X 29.E 90 SE 0.0x 21.1+ 3.0x 29.8= 90 Total 5 780 Internal Gain Btu/hr Occupants4 Occupants x 230 Btuh/oCC.� . 920 E ui ment 1 _ Dwelling Units x 1,6001 Btuh 1,600 Infiltration: 1.064 x 0.87 x 131.16 x r 34 =- 4109 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM . 37,744 Latent Gain Btu/hr Occu ants F-4]' Occupants X 200 Btuh/occ. ` _ I 800 Infiltration: 4,771 x 0.87 x 131.16 x 0.00263 = 1426 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,226 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number. Page: 33 of 36 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsk Residence 8/15/2007 Room Information Desi n Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,070 sf Outdoor Web Bulb Temperature:. 78oF Indoor Dry Bulb Temperature: 78oF Outdoor -Daily Range: 340F Orientation Area I U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1 r-fi- 1 Hart Te .raWFo Nffo..nro rrl TM Fenestration Fxd Wdw 91 Frnch Dr(l) Fxd Wdw 2 Fxd Wdw 3 Fxd Wdw 4 Fxd Wdw 5 Pocket Sldnq GIs Dr 6 Fxd Wdw 7 Fxd Wdw 8 Fxd Wdw 9 Btu/hr 0 Orientation Btu/hr x X x x x GLF x Unshaded Area = GLF = = = = = = x SW 0.0 x 30.0 = 895 SW x 18.2 60.0 x 1,478 = 0.0x 21.1+ x 29.8= 128 x 0.0x = 4.3X 29.8= X, SW 0.0x x 4.3X = 128 SW x 21.1+ 4.3x x 128 = 0.0 19.1 x 26.4 2,009 x 0.0X = 3.0X 29.8= x SW 0:0x x 3.0x = 90 SW x 21.1+3.0 X 90 = x x _ X X = �. x' x = Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1 r-fi- 1 Hart Te .raWFo Nffo..nro rrl TM Fenestration Fxd Wdw 91 Frnch Dr(l) Fxd Wdw 2 Fxd Wdw 3 Fxd Wdw 4 Fxd Wdw 5 Pocket Sldnq GIs Dr 6 Fxd Wdw 7 Fxd Wdw 8 Fxd Wdw 9 Btu/hr 0 Orientation Btu/hr Shaded Area X x x x GLF + + + + Unshaded Area x x x x x GLF = = = = = = Btu/hr SW 0.0 21.1 30.0 29.8 895 SW 0.0 18.2 60.0 24.6 1,478 SW 0.0x 21.1+ 4.3x 29.8= 128 SW 0.0x .21.1+ 4.3X 29.8= 128 SW 0.0x 21.1+ 4.3X 29.8= 128 SW 0.0x 21.1+ 4.3x 29.8 128 SW 0.0 19.1 76.0 26.4 2,009 SW 0.0X 21:1+ 3.0X 29.8= 90 SW 0:0x 21.1+ 3.0x 29.8 90 SW 0.0x 21.1+3.0 29.8 90 . I Page Total I 5,165 Internal Gain Btu/hr Occu ants 4 Occupants x 230 Btuh/occ. = 920 E ui ment Dwelling Units x 1 600 Btuh _ 1,6001 Infiltration: 1.064 x 0.87 x ' 131.16 x 34 = 4109 Air Sensible CFM - ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37 744 Latent Gain Btu/hr Occu ants F 41 Occupants x 200 Btuh/occ. = 800 Infiltration: 4,77,1 x ' 0.87 x 131.16 x 0.00263 = 1 426 Air Latent CFM ELA., pW r TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,226 EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page: 34 of 36 .ti RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsky Residence 8/15/2007 Room Information Design Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,070 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area: U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 31 Fxd Wdw 33 Fxd Wdw 34 Fxd Wdw 35 Fxd Wdw 36 Fxd Wdw 22 Fxd Wdw 23 Fxd Wdw 24 Fxd Wdw 25 Fxd Wdw 26 Orientation Btu/hr x x x x x x x xx X x xx x X X x X x x x x x x x x x + + + = - = = = = = = = = = = X X x X X X x x GLF = = = = = = = = = Btu/hr W 0.0x 21.1+ ,. 64.5 43.7 2,816 W 0.0x 21.1+ 4.0 43.7 175 W 0.0X 21.1+ 4.0 43.7 175 W 0.0x 21.1+ 4.0 43.7 175 W 0.0X 21.1+ 4.0 43.7 175 NW 0.0 21.1 32.0 33.3 1,066 (NW) 0.0 21.1 18.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw 31 Fxd Wdw 33 Fxd Wdw 34 Fxd Wdw 35 Fxd Wdw 36 Fxd Wdw 22 Fxd Wdw 23 Fxd Wdw 24 Fxd Wdw 25 Fxd Wdw 26 Orientation Btu/hr Shaded Area X X x GLF + + + Unshaded Area X X x X X X x x GLF = = = = = = = = = Btu/hr W 0.0x 21.1+ ,. 64.5 43.7 2,816 W 0.0x 21.1+ 4.0 43.7 175 W 0.0X 21.1+ 4.0 43.7 175 W 0.0x 21.1+ 4.0 43.7 175 W 0.0X 21.1+ 4.0 43.7 175 NW 0.0 21.1 32.0 33.3 1,066 (NW) 0.0 21.1 18.0 33.3 600 NW 0.0x 21.1+ 4.0X 33.3= 133 NW 0.0x 21.1+ 4.0X 33. 133 NW 0.0x 21.1+ 4.0X 33.3= 133 Page Total i 5,581 Internal Gain Btu/hr Occupants 74 Occupants , X 230 Btuh/OCC. 920 E ui ment 1 Dwelling Units X 1,600 Btuh _ 1 600 . Infiltration: t06a x o.87 x 131.16 x Air Sensible CFM- ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,744 Latent Gain Btulhr Occu ants 0 Occupants ° X 200 Btuh/occ. = 800 Infiltration: 4,771 x 0.87 x 131.16 x 0.00263 = 1426 Air Latent CFM ELA ., pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,226 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 35 of 36 i TITLE 24 REPORT ' Title 24 Report for: -K- es ita " 53148 Via Dona La Quint=, CA 92253 -. All 1 y I Project Designer: V AA Group' - . 20341 Sw Birch St Newport Beach, CA 92660 949-250-1909, Aeport Prepared By. Micah CombsLA QIJINTA l C.M. Ener ConsultingC�T1( OF 9Y BUILDING & SAFETY DEPT. Y P.O. Box 4655 Palm Desert, CA 92261 APPROVED FOR C (760) 449=1308 NSTRUCTION DATE �� 07 BY . Job Number: , K �� tio0 Date: P� 8/15/2007,-.' The EnergyPro computer program has been used to perform the calculationssummarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 1086 L., TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance V 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating,and Cooling Loads Summary 9 .,Room Load Summary 10 Room Heating Peak Loads 11 Room Cooling Peak Loads 12 EnergyPro 4.3 by EnergySoft Job Number: ;, User Number: 1086 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Zidnsk-G.uest_Casitia n/a ft2 Raised Floor Area: 8l, 5/2007 Project Ti a _5.3J48-LiaLDona-La-Quinta 854 ft2 Average Ceiling Height: Date Project Address 1.00 Number of Stories: Building Permit # �ocu�M Ealong�tCon .ulti.ng (760)449-1308 plan Check/Date ne Fner_gvPro CA ClimafeZone-15 Field Check/Date Compliance Method Climate Zone TDV Standard Proposed Compliance _ kBtu/sf- r) Design Design Margin Space Heating 2.29 1.59 0.69 Space Cooling . 80.21 57.69- 22.52 Fans 11.46 10.24 1.21 Domestic Hot water 20.30 23.51 -3.22 Pumps 0.00 0.00 0.00 Totals 114.25 93.04 21.21 Percent better than Standard: 18.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [)-d Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 214 ft 2 Avg. U: 0.38 Ratio: 25.1% Avg. SHGC: 0.31 BUILDING ZONE INFORMATION Total Conditioned Floor Area: 854 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 854 ft2 Average Ceiling Height: 11.0 ,ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Zone Name Floor Area Volume Units Zone Type ±1 C #1 Rsa _9.394 --LO0_ _Conditioned OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Root WbDd _854- _0-026_ R_38 R-0-0_ 0_ 0 Wall_ Wood_ 37-8_ _0_0.69_-R21._R-0_0 0_ 9Il Wall_ W .d_ _235_ 0_069- ER -21 -R=0.0_-90_ 9.0 Wall- Wood- -38.0_ _0 62 R-21 _R_0-0_ X8.0_ 90 Wall_ wood _267- _0..062 R-21 R -6a-279_90 Thermostat Vent Type Hgt. Area -Setback- 2 -Na Gains Condition Y / N Status JA IV Reference Location / Comments X ❑ New _01=A8 Zona 1 IX ❑ New 0.9-A6 Zone 1 [XI ❑ N.ew 09=A6 .Zone 1 (XI ❑ New, 7nna 1 IX 0 New 996 Zone 1 ❑❑ ❑❑ Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Zirinsky Guest Casita Project Title Window Date 8/15/2007 FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments -1- window Front (N)_ _3.0_0- -0_3$Dl1FRC__0_3O -NFRC 0_ -9R New -103 lone 1 2 Window Front (N) 41.0 0.390 NFRC 0.28 NFRC 0 90 New 100 Zone 1 3 Window Front (N) 8.0 0.350 NFRC 0.38 NFRC 0 90 New 101 Zone 1 4 Window Front LL 13.3 0.350 NFRC 0_38 NFRC 0 90 New 102 Zone 1 5 Window Front (N) 30.0 0.380 NFRC 0.30 NFRC 0 90 New 111 Zone 1 6 Window Lek (E) 18.9 0.380 NFRC 0_30 NFRC 90 90 New 110 Zone 1 L Window Left (E) 18.9 0.380 NFRC 0.30 NFRC 90 90 New 109 Zone 1 8 Window Rear (S) 6.0 0.350 NFRC 0.38 NFRC 180 90 New 108 Zone 1 6 Window Rear (,9) 6.0 0.35g NFR 0.38 NFRC 180 90 New 107 Zone 1 10 Window Rear (S) 6.0 0.350 NFRC 0_38 NFRC 180 90 New 106 Zone 1 11 Window Rear (S) 6.0 0.350 NFRC 0_38 NFRC 180 90 New 105 Zone 1 12 Window Right (W) 30.0 0.380 NFRC 0_30 NFRC 270 90 New 104 Zone 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 - 9 Bug Screen 0.76 10 Bug Screen 0.76 11 By Screen 0.76 12 Bug Screen 0.76 - THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments \ PERIMETER LOSSES Condition Location/ Insulation Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 134 None No Insulation 26-A1 New Zone 1 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:4 of 13 1 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Zirinsky Guest Casita 8/15/2007 Project Title Date HVAC SYSTEMS Heating- Location Type Minimum Eff Cooling Type Minimum Condition Thermostat Eff Status Type HVAC #1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct Condition Ducts R -Value Status Tested? HVAC #1 Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length. Diameter Thick. WATER HEATING SYSTEMS Water Heater System Name Type Distribution Rated Tank # in, Input Cap. Syst. (Btu/hr) (gal) r Energy Tank Insul. Condition Factor Standby R -Value Status or RE Loss (%) Ext. Standard Gas 50 gal. Small Gas No Pipe Insulation 1 40,000 50 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Len th ft - Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (p Business & Professions Code) Documentation Author Name: _Q�„�� VA'3_W Name: Micah Combs Title/Firm: AA Group Title/Firm: C.M. Energy Consulting Address: 20341 Sw Birch St Address: P.O. Box 4655 Newport B ach CA 92660 kalgMes A 92261 T ephone: 491 0-1 09 Lic. #: Tele hone: 7 0 4 -13 $• Z7.07 (si6nature) (date) (sign cure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:5 of 13 I Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Zirinsky Guest Casita 8/15/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a �., r. ... ...y rr. .. �....y ...... Plan Field The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA4BF / PGC1RC (4 Ton)" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. Run Initiation Time: 08/15/07 07:21:42 Run Code: 1187187702 EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page:6 of 13 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures •§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value:_______, ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ 0 ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ ' § 150(9): Vapor barriers mandatory in Climate Zones 14 and .16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rale no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑XE-1CF-6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped, all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ \. § 1506): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R•value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater lank, non -recirculating systems, and entire. ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between healing source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-6 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. ` 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Coirporatioh. ❑ ❑ ❑ EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Page:7 of 13 Mandatory Measures Summary: Residential- (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in. the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ E ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ O ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ X❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. „ 7. Flexible ducts cannot have porous inner cores. ❑ FAI ❑ § 114: Pool and Spa Healing Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ 0 ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ 0 ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air light (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:8 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zirinsky Guest Casita 8/15/2007 SYSTEM NAME FLOOR AREA HVAC #1 854 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM I Sensible 523 12,806 1,388 404 15,056 0 1,163 1,199 0 0 0 0 0 0 0 ' 0 0 1,163 1,199 15,131,388 17,454 MAYTAG PSA4BF / PGC1 RC (4 Ton) 41,354 0 73,000 Total Adjusted System Output a1,35a o 73,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.3 of 105.0 of 105.0 of Supply Air Ducts Outside Air 0 cfm Heating Coil Supply fan 104.3 of 1600 cfm ROOMS 69.3 of 70.0 of Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 117.0 / 77.6 of 78.7 62.8 of 55.0 / 53.7 of 55.0 / 53.7 °F Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 55.7 / 54.0 of 1600 cfm 42.0% R.H. ROOMS 78.7/62.7 ° F 78.0 ! 62.5 of EnergyPro 4.3 by EnergySofl User Number: 1086 Job Number: Paoe:9 of 13 BROOM LOAD SUMMARY PROJECT NAME Zirinsky Guest Casita DATE 8/15/2007 SYSTEM NAME HVAC #1 FLOOR AREA 854 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zirinsky Guest Casita 1 523 12,806 1,388 523 12,806 1,388 404 15,056 f f: ,t. PAGE TOTAL 1 523 12,806 1,388 404 15,056 TOTAL 523 12,806 17,388E404 15,056 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page:10 of 13 ROOM HEATING PEAK LOADS Project Title Date Zirinsky Guest Casita 8/15/2007 Room Information Design Conditions Room Name Zirinsky Guest Time of Peak Jan 12 am Floor Area 854 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value n T OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 12.644 Infiltration: [ i.001 x 1.064 x 85a x 11.00 x 0.329 / 60] x as = 2 411 Schedule Air Sensible Area Ceiling Height ACH p7 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,056 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 11 of 13 854.0 X X x X x x x X x X X x x X x X x x x X x x x x x x x x x X X x x x x x xx x x 0.0260 x x x X x X . ' X X x x x X X X x x X X x x x x x x x x x x x X X x x x x x x x 44 = = = = = = = - = = = = = = =502 = = = = = = = = = = = = = = = = - = = 977 perimeter = 134.0 0.7300 44 4,304 378.2 0.0690 44 1,148 30.0 0.3800 44 502 41.0 0.3900 44 704 8.0 0.3500 44 123 13.3 0.3500 44 205 30.0 0.3800 44 502 235.2 0,0690 44 714 18.9 0.3800 44 316 18.9 0.3800 44=316 379.5 0.0690 44 1,152 6.0 0.3500 44 92 6.0 0.3500 44 92 6.0 0.3500 44=92 6.0 0.3500 44 92 2670. D&9 44=811 30.0 0.3800 44 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 12.644 Infiltration: [ i.001 x 1.064 x 85a x 11.00 x 0.329 / 60] x as = 2 411 Schedule Air Sensible Area Ceiling Height ACH p7 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,056 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 11 of 13 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsk Guest Casita 8/15/2007 Room Information Design Conditions Room Name: Zirinsky Guest Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 854 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78oF Outdoor Daily Range: 340F e aurraces .21.2x6.1 .21.2x6.1 .21.2x6.1 Orientation Area X X X X X x x X x x x x U -Factor X x X X X X X X x X x X CLTD 1 = = = = = = = = = = - = Btu/hr N 854.0 0.0180 56.0 861 N 378.2 0.0690 23.0 600 E 235.2 0.0690 33.0 536 S 379.5 0.0690 26.0 681 W 267.0 0.0690 33.0 608 18.7 562 0.0 18.7 18.9 36.5 691 0.0 18.7 18.9 36.5 691 0.0x 21.1+ 6.0X 21.2= 127 0.0x 21.1+ 6.0x 21.2 127 0.0x 21.1+ 6.0X 21.2= 127 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 3 285 1. Cooling Load Temperature Difference (CLTD) Fenestration _ r✓°--'- _i �'�' Fxd Window Vertical Slider Vertical Slider Vertical Slider Fxd Window Fxd Window Fxd,Window Orientation i ,nternal Gain s- - OccupantsP11 Occupants x Equipment Dwelling Units x 230 Btuh/occ. _ 1,600 Btuh = Page Total i 4,082 Btu/hr 920 1.6001 'Infiltration: 1.064 x 0.87 x Shaded Area x x x x X x GLF + + + + + + Unshaded Area X x x x x x x GLF = = = = = = Btu/hr 0.0 18.7 30.0 18.7 562 0.0x 18.2+ 41.0X 18.2= 746 0.0x •21.1+ 8.0 21.1= 169 0.0 21.1 13.3 21.1 281 0.0 18.7 30.0 18.7 562 0.0 18.7 18.9 36.5 691 0.0 18.7 18.9 36.5 691 0.0x 21.1+ 6.0X 21.2= 127 0.0x 21.1+ 6.0x 21.2 127 0.0x 21.1+ 6.0X 21.2= 127 230 Btuh/occ. _ 1,600 Btuh = Page Total i 4,082 Btu/hr 920 1.6001 'Infiltration: 1.064 x 0.87 x 54.11 x, Air Sensible CFM ELA dn'T R "~...I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,806 Latent Gain Btu/hr Occupants 7-41 Occupants x I Btuh/occ. = 800 Infiltration: 4,77 x 0.87 x 54.11 x 0.00263 = 588 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,388 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 12 of 13 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Zirinsky Guest Casita � 8/15/2007 Room Information Design Conditions Room Name: Zirinsky Guest Casita Outdoor Dry Bulb Temperature: 112°F Floor Area: 854 sf Outdoor Web Bulb Temperature: 78°F Indoor Dry Bulb Temperature: 78 °F Outdoor Daily Range: 340F Surfaces Orientation Area U -Factor CLTD X x = x x = x x = X x = X X = X x = X X = X x xX = x x X X = x x = through an interior surface to another.room. Page Total Btu/hr Shaded Unshaded Orientation Area GLF Area GLF Btu/hr S 0.0x 21.1+ 6.0 X 21.2= 127 W 0.0 X 18.7 + 30.0 X 36.5 = 1,096 x + x = x + X = x + x = x + x = X + x = x + x = x + X = x + x = x + X = Page Total 1 223 .!�-rinternal Gain Btu/hr �+ '(6— OccupantsB4 Occupants X 230 Btuh/OCC. _ 920 E ui ment 1 Dwelling Units X 1,600 Btuh 1,6001 n—,.•' Infiltration: 1.064 x 0.87 x 54.11 x 34 _ - 1,695 Air Sensible CFM ELA OT i TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,806 Latent Gain Btu/hr Occu ants � Occupants x 200 Btuh/occ. 800 Infiltration: 4,77 x 0.87 x 54.11 x 0.00263 = 588 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,388 EnergyPro 4.3 by EnergySoft User Number: 1086 Job Number: Page: 13 of 13