05-2925 (SFD)• � � till • �r P.O.. %BOX 1504 ^� VOICE (760)-77T7012 � 1 4 78-495 CALLE TAMPICO FAX (760)777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777=7153, BUILDING .PERMIT - Date: 10/19/05 Application Number. C05=000.0.2.925— - Owner: Property Address: .52920. VIA DONA M/M JOHN STRINGER D APN: 772=410-999-10 -298944- 18278 BEAROATH TRAIL :'Application description: DWELLING --SINGLE FAMILY DETACHED . EDEN PRAIRIE, MN 55347 Mop Property Zoning: LOW DENSITY RESIDENTIAL (� O Application valuation: 535047 C�� 3 Zo�S Contractor:/AJq Fri Applicant: Architect or Engineer: PIERCE CORPORATION, ANDREW �pF0460 V. P.O. BOX 3420 PALM DESERT, CA 922.61 (760)346-3228 Lic. No.: OOR SQUARE FOOT Lic. No.: 671203 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9. (commencing with - - .I hereby affirm under penalty of perjury one of the following. declarations: - Section 7000) of Division 3 of the Business and Professionals Code, and -my License is in full force and effect. - I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided , License C ass: B ' ' License N .: .6 7 12 0 3 - — for by Section 3700 of the Labor_ Code, for the performance of the work for which this permit is Da U3_ '� issued. 6 l CC_6n ra_C.c-r:_/ ry I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor. - Code, for.the performance of the work for which this permit is issued. My workers' compensation . �JOWNERAIIIILDER DECLARATION - insurance carrier and policy number are: • I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND - Policy Number 0014314-2005 following reason (Sec. 7031.5, Business and Professions Code: -Any city or:county that requires a permit to- - -_ I certify that,. in the performance of the work for which this permit*is issued, I shall not employ any construct,. alter, improve, demolish, or repair any structure, prior to its issuance; also requires the applicant for the person in any mannersoas to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State _ - and agree that, if 1 should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - 3700 of.the Labor Cod shall forthwit on ly ith those provisi S. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ( / any applicant for a permit subjects the applicant to a civil penalty of not"more than five hundred dollars ($500).:".Applicant: I r4s 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and _ the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COM NSATIONCOVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, 'SUBJECT'AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden.of proving that he or she did not build or , - improve for the purpose of sale-.). - - APPLICANT ACKNOWLEDGEMENT 1 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7644, Business and Professions Code: The Contractors' State License Law does not apply, to an owner of - conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed - 1. Each personupon whose behalf this application is made, each peison at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant.to any,permit issued as a result of this application, - (_),I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quints, its officers, agents and employees for any act or omission related to the work being . - performed under or following issuance of this permit. - Date: Owner: - 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of. such permit, or cessation of work for 180 days will subject " " CONSTRUCTION LENDING AGENCY - - permit to cancellation.. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to building construct' ndhereby authorize representatives of this c0 ty to enter upon the above-mentioned prope y or inspecti p po -Lender s Name: _ 11` _ `._Date:-`— Signature(Applicant'orAgent): " Lender's Address: - LQPERMIT s t. Application Number, 05-000029.25 Permit BUILDING PERMIT Additional desc Permit Fee 2147.50 Plan Check Fee 1395.88 Issue Date Valuation 535047 - Expiration Date 4/17/06 Qty Unit Charge Per •Extension BASE,FEE 2039.50 _. 36.00. 3:0000 THOU -BLDG 500,001-1,000,000 108.00 Permit . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 292.22`, Plan Check Fee 73.06 Issue Date . . . . Valuation . . 0 Expiration Date 4/17/06 Qty Unit Charge Per Extension BASE FEE. 15.00 6153.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 215.36 ' 2343.00 „ .0200 ELEC GARAGE OR NON-RESIDENTIAL 46.86 1.00 15.0000 EA.ELEC TEMPORARY POWER POLE 15.00 ----------- _ Permit GRADING PERMIT \ Additional.• desc . Permit Fee 15.00 Pian Check Fee .00 Issue Date Valuation . . . . 0 Expiration•Date 4/17/06 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . ." MECHANICAL Additional desc . Permit Fee . . . 170.00 Plan Check Fee 42.50 Issue Date Valuation . . . 0 Expiration Date 4/17/06 Qty Unit Charge. Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 9.00 6:5000 EA MECH VENT FAN 58.50 1.00 6.500.0 EA MECH EXHAUST HOOD* 6.50 - LQPERMIT Application Number 05-,00002925 Permit . . . .PLUMBING - Additional desc . Permit -Fee 235':50 Plan Check Fee 58.88 Issue Date Valuation . . 0 Expiration Date.. 4/17/06 Qty Unit Charge Per Extension BASE FEE 15.00 28.00 6.0000 EA PLB FIXTURE 168.00 1.00 15.0000 EA .• PLB BUILDING SEWER 15.00 1.00 7.5000"EA PLB WATER HEATER/VENT 7..50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 16..00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 .15.0000 EA• PLB GAS METER 15.00 - Special Notes and Comments. SFD - 6153 SQ.FT. LIVING R -3 -OCCUPANCY, TYPE V -N CONSTRUCTION 2001 CODES. **PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA, WATER FEATURES OR FREESTANDING BBQ** ' Other Fees . . . . - ---- - - ------- ART IN PUBLIC PLACES -RES 837.61 ' DIF COMMUNITY'CENTERS-RES 97.00 DIF CIVIC CENTER. -'RES 366:00 ENERGY REVIEW FEE 139.59 DIF FIRE PROTECTION -RES 97.00 DIF LIBRARIES = RES 225.00 'DIF PARK MAINT FAC'- RES ,5.00 DIF PARKS/REC -RES 502.00 STRONG MOTION (SMI) - RES 53.50 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited. Due --------- Permit Fee Total - ------------- - ---------- 2860.22 .00 .00 •2860.22 • Plan Check Total 1570.32 750.00 .00 820.32 Other Fee Total 3435.70 .00 .00 3435.70 Grand Total 7866.24 750.00 .00 7116.24 " LQPERMIT • - Building Addressrj2•g2� ��% �1�:i• Tihf 4 4 a" P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 APPLICATION ONLY owner S►* 1*IA'['jZ G BUILDING: TYPE CO�N7ST. VA / OCC. GRRP. I G/ Mailing A.P. Number ` `d ` / 4/4/ / Address r.0. Pax ;4zo Ae C'ty�+++'���''•�� Zip ae Tel. �n Legal Description 0 O Contracm 00;'er-T ' I61 1 i60' � 7jZZ$ Project Description uaw Address .0, Vim 3420 Cit Zip Tel. M 09"AFT q%961 160444218 State Lic. City & bassif. IN Lic. #00 fiL, Arch., Engr, Designer V*,* AW0146ter Address Tel - 4hmlr- 7A 4 Nil, W141144 -11107 ILic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Size �7� ��3 Cin( O Stories 2 FINA IN yk �•� New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation 000 of) PERMIT AMOUNT Plan Chk. Dep. . 00 Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: _ Validated by: Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE I F'15.Liurry r"w1ONALTITLE CQ S ViAb DEPARTTIVIE, NT WHEN RECORDED MAIL TO: Mr. and Mrs. John Stringer 18278 B6arpath Trail' Men Prairie, 10' 55347 MAIL TAX STATEMENT TO: SAME AS ABOVE DOCUMENT TRANSFER TAXI 584.10 XX Computed'on the consideration or value of property conveyed;OR Computed on the consideration or value less liens or encumbrances remaining at the time of sale. 41 .':`225?' C 4 Page -1. 'of 51't_ Doi: '- I aic Pdid- Re-l-orded"il,h--'Official - Records County - .'Of - River . side G 'County CleFk & Recorder [I[II III [1111 IIII 1111 M S U PAGE SIZE" OA PCOR NOCOR SMF MISC. LIUOr r -T -+,I-,I A R L COPY LONG REFUND NCHG EXAM -7 Id A- 6 � LLS Signature of Declarant or Agent. determining tax - Firm Name to GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to John Stringer and Karen Stringer, Huband and Wife as Joint Tenants ("Grantee','), the real property located in the City of La Quints; ,County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein• as Exhibit "A". SUBJECT TO all matt * ers of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: ND LA QUINTA -PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty'Investors, Ltd. an Ohio limited liability compa its managing mber By:. Jos 2ph.L. Arenson Authorized Representative � M VIPolo,,r� V,.,- 0/z©'d rq,.::rq) _jaGU1-I1q LIUOr r -T -+,I-,I lk STATE OF California COUNTY OF Riverside On March 24, 2004 before,rne-, K. Larby,;Notary Public (Name, Title of Officer) personally appeared Joseph L. Arenson personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the Within in and acknowledged to me that h'e/she/they : executed the same inhis/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon_ behalf of which the person(s) acted, executed the instru ment. WITNESS my hand and official seal. r f OFFICIAL SEAL • . K. LARDY COMM 0 260797 C • d Notary Public - Califomla (Sig6, ature of ?Pr ary F�ubllc). V a RIVERSIDE COUNTY. �.- My Commission Expirr_s JUNE 24, 2004 (This area for notarial seal), i 01 -74A -a J 7011 a-.r_r_ Tro r,_Qc-. _jak�ut_faa uunr cTT_-Inr Parcel No. 1: Lot 10 (the "Lot") of Tract No. 29894-4, in the City of La Quinta, as shown by Map on file in Book 351, Pages 49 to. 57jn1clusive,-'of Maps, in the Office of the County Recorder of Riverside County, California. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together, with the right to grant and transfer all or -a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes, over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (asamended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No: 2002- 74593 8, of Official Records of Riverside County, California (the "Official Records"); 2. The Supplementary Declaration of Annexation of Property, recorded on March 4, 2004, as Instrument No. 2004-0151981, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies.. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry.. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in.a court of law. Grantee shall'be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress,`egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: 1. Non delinquent general, special and- supplemental real property taxes and assessments. qr�.c a j 701 )' '#,CC Teo rQCFCZ- .J@GL11 J1q Ullor r - T. -t7M COMP—P.T.--inr 9� ' ci 14101 ss 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights -of. --way of record including, without imitation, *the Declaration and the Map for Tract No. 29894-4: Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and . approves all of the foregoing in this Grant Deed, (b) grants to•Grantor and The Hideaway Owners Association_ such powers and rights as are set forth in the Declaration,. and (c) accepts, covenants and agrees to be bound by and -assume performance of all of the applicableprovisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice,. which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set_ forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined abN1�1,i�G� �'Cj , 2004. Stringer wren Stringer .STATE OF 1111 ) COLJNTY OF On 2004, before me, the undersigned, a notary public in and for said State, personally appeared John and Karen Stringer; personally known to me (or proved to me on the basis 'of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons; or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. (SEAL] Signature My commission expires: P -X1 ys ■ s ANNETTE KELLY ~, 4 NOTARY PUBLIC- MINNESOTA y My Cam mission EiOres Jan. 31, 2005 r ■ C317, i0(T ' J 7&%) 1 4_r. r. --r. -iTITLE-24 REPOR Title 24. Report for: Andrew Pierce Corporation, i Lot 10D -Hideaway La Quinta, Ca 92253 Project Designer: BBG Architects 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 (714) 434-2506 a Report Prepared By:,4,D Tim Scott H & H Air Conditioning 74-991. Joni Drive #20 C.ev Palm Desert, CA 92260-2043 (760) 340-3088 I CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED, n FORCONSTR_UCTI i DAT // BY .�� Date: 9/7/05 heEnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is i.,thorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 BuildingEnergy Efficiency Standards. . r This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 ByEnergySoft Job Number: User Number: 5533 y2 �jZO Uia i Certificate of Compliance: Residential (Part 1 of 2) CF -1 R . •Andrew Pierce Corporation 9/7/05 Project Title a e Lot 10D -Hideaway La Quinta Project Address H & H Air Conditioning (760) 340-3088 ocumen a ion Author i a ep one Computer Performance 15 Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only Building Permit- -Plan Check Date Field ec Date GENERAL INFORMATION Const. Total Conditioned Floor Area: 6,153 ft2 Average Ceiling Height: 10.6 ft Total Conditioned Slab Area: 5,244 ft2 Building Type: U -Value. (check one or more) Wood ®' Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition 0.756 Covered Slab w/R-0.0 Perimeter Insulation Front Orientation: (West) 255 deg Floor Construction Type: F Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION ❑X❑ Component Type , R-38 Roof (R.38.2x14.16) R-21 Wall (W.21 .2x6.16) Slab On Grade Slab On Grade Solid Wood Door FENESTRATION Shading Devices Type Const. Area Frame Assembly Location/Comments. Type U -Value. (attic, garage, typical, etc.) . Wood 0.028 Exterior, Roof Wood'. 0.059 Exterior Wall Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation Na . 0.756 Exposed Slab w/R-0.0 Perimeter Insulation None 0.387 Exterior Door . Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins - (SF) U -Factor SHGC Shading Yes / No Yes / No Left (North) 86.5 0.60 0.46 Bug Screen ❑ .X❑ ❑X❑ Rear (East) 15.0 0.60 0.46 Bug ScreenX❑ ❑ El EK Rear (East) 15.0 0.54 0.46 Bug Screen 1K ❑ ❑ X❑ Rear . (East) 54.0 0.60 0.46 Bug Screen ❑ 0 ❑ X❑ Right (South) - 20.0 0.55 0.46 Bug Screen ❑ X❑ ❑ ❑X Right (South) 49.0 0.60 0.46 Bug Screen ❑ X❑ ❑ ❑X Right (South) 30.0 0.60 0.46 Bug Screen ❑X ❑ . ❑ ❑X Front (West) 67.0 0.60 0.46 Bug Screen x❑ ❑ ❑X❑ Front (West) 24.0 0.55 0.46 Bug Screen 0 ❑ ❑X❑ Front (West) 40.0 0.54 0.46 Bug ScreenX❑ ❑ ❑ X❑ Front . (West) 40.0 0.55 0.46 Bug Screen ❑ X❑ ❑ X❑ Left (North) 15.0 0.60, 0.46 Bug Screen a ❑ . ❑ o Run Initiation Time: 09/01/05 15:11:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 41 Certificate of Compliance: Residential .(Part 1 of 2) CF -1 R Andrew Pierce Corporation 9/7/05 Project Title Date Lot 10D -Hideaway La Quinta ' rojec ress Building Permit . H & H Air Conditioning (760) 340-3088 Plan Check ate ocumen a ion Author a ep one Computer Performance 15 Held Checkate Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6;153 ft2 Average Ceiling Height: 10.6 ft Total Conditioned Slab Area: 5,244 ft2 Building Type: (check one or more) Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 255 deg Floor. Construction Type: X❑ Slab Floor Number of Dwelling Units: 1.00 . Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame .Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) =ENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (North) 40.0 0.55 0.46 Bug Screen X❑ ❑ ❑ XD Left (North) 40.5 0.60 0.46 Bug Screen ❑ X❑ ❑ x❑ Left (North) 12.5 0.60 0.46 Bug Screen . X❑ ❑ ❑ K Rear (East) 24.5 0.60 0.46. Bug Screen 1K , ❑ ❑ ❑X Rear (East) 200.0 0.55- 0.46 Bug Screen El, ❑ ❑ ❑X Rear (East) 24.0 0.54 0.46 Bug Screen ❑ X❑ a a Right (South) .20.0 0.55 0.46 Bug Screen XO ❑ ❑ ❑X Front (West) '55.0 0.60 0.46 Bug Screen ❑ Q ❑ ❑X Front (West) 64.0 0.55 0.46 Bug Screen ❑ X❑ ❑ ❑X Leff (North) 12.5 0.60 0.53 Bug Screen ❑ X❑ ❑ ❑X Rear (East) 30.0 0.60 0.46 Bug Screen ❑ X❑ ❑ ❑X Right (South) 44.0 0.55 0.46 Bug Screen XO ❑ ❑ O Run Initiation Time: 09/01/05 15:11:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 41 I • • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Andrew Pierce Corporation 9/7/05 rojec Title ae Lot 10D -Hideaway La Quinta Project Address H & H Air Conditioning (760) 340-3088 ocumen a i o—n-A-uThor I a ep one Computer Performance 15 Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned -Floor Area: 6,153 ft2 Average Ceiling Height: 10.6 ft Total Conditioned Slab Area: 5,244 ft2 Building Type: .(check one or more) ® Single Family Detached ❑ Addition ❑' Single Family Attached ❑ ExistingBuilding' ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 255 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 , Number of Stories: 1 ❑ Raised Floor Building Permit# Plan Check / Da-te _Fiel-d_Cec a e BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) rtrvta I KA I IUN Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Right '(South) 10.0 0.60 0.46 Bug Screen ❑X ❑ ❑ • X❑ Rear (East) 40.0. 0.54 0.46 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 40.0 0.55 0.46 Bug Screen ❑ X❑ ❑ X❑ Front (West) 15.0 0.54 0.46 _ Bug Screen ❑ X❑ ❑ ❑X Rear (East) 24.0 0.55 0.46 Bug Screen ❑X ❑ ❑ ❑X ❑ ' ❑ ❑ F. 1:1 1:1 El El El F-1 El EI 1:1 El F-1 El El F ❑ 1:1 El ❑❑ Run Initiation Time: 09/01/05 15:11:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number. 5533 Job Number: Page:5 0 41 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R •Andrew Pierce Corporation 9/7/05 ProjeCt Title Uate HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -2 & 3 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -4 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -5 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts,in Attic 4.2 Setback HVAC -2 & 3 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -4 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -5 WATER HEATING SYSTEMS Rated .1 Tank 1 Energy Facts External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN CG52-75T75- Large Gas 1 75,100 75 0.79 0.0244 0.0 SERICAN CG52-75T75- Large Gas 1 75,100 75 0.79 0.0244 0.0 • 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS • COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: lip 1_ M Title/Firm: BBG Architects Address: 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 Telephone: (714) 434-2506 Lic. LX 'tHalos (si ature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Tim Scott Title/Firm: H & H Air Conditionin Address: 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 Telephone: k60049-3088 -3088 (signature) (date) . signature/stamp) (date) Run Initiation Time: 09/01/05 15:11:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 41 Certificate of Compliance: Residential (Addendum) CF -1 R Akndrew Pierce Corporation 9/7/05 ro/ect Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Pian I Fialrl The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 794 sgft Covered Slab Floor, 3.50" thick at Owner's Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 282 sgft Exposed Slab Floor, 3.50" thick at Owner's Suite The HVAC System "HVAC -2 & 3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2 & 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 210 sgft Covered Slab Floor, 3.50" thick at Great/Dining/Kitchen/Office HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2820 sgft Exposed Slab Floor, 3.50" thick at Great/Dining/Kitchen/Office The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 303 sgft Covered Slab Floor, 3.50" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 98 sgft Exposed Slab Floor, 3.50" thick at Guest Bedroom The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas, HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS orovider. The HERS rater must rinmimant fho fiald varifirnfinn -l rlinn nncfir #e ti r r r F ♦k_ nr wig a corm, U -um. die HP1�C ys em includes Retrigerant Charge and Airflow Credit (ora certified HER ra er must provide erifification of the TXV, or measure the Refrigerant Charge and Airflow. an Fie ld The HVAC System "HVAC -2 & 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. e ys em includes Refrigerant Charge and Airflow-CFe-d-iffo—ra ce i le ra er mus prove verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 09/01/05 15:11:13 un o e: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 41 Certificate of Compliance: Residential (Addendum) CF -1 R &ndrew Pierce Corporation 9/7/05 NWroject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ---- - - -- - -...._ . ., ...- Plan • Field The HVAC:System "HVAC-5",includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 399 sgft Covered Slab Floor, 3.50" thick at'Casita HIGH MASS Design(see C -2R) - Verify Thermal Mass: 338 sgft Exposed Slab Floor, 3.50" thick at Casita F HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. EnergyPro 3.1 By EnergySoft - User Number: 5533 . Job Number: .. Page:8 of 41 Mandatory Measures Checklist: Residential -(Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an • asterisk (^) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures �§ 150(a): Minimum R-19 ceiling insulation. f ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. r ®`§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior walls). mass ❑ *.§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): *Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ® § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. © § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and,unconditioned spaces designed to limit air leakage. r 2. Fenestration products (except field fabricated) have label with certifiedU-Factor, certified Solar Heat Gain, j Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑, §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. a§ 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X Installation Fireplaces, §150(e): of Decorative Gas Appliances and Gas Logs. t^ 1. Masonry and factory -built fireplaces have: f a. Closeable metal or glass door b. Outside air intake with damper and control•, r c. Flue damper and control 2: No continuous burning gas pilots allowed. r r Space Conditioning, Water Heating and Plumbing System Measures ® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. . ® §150(i): Setback thermostat on all applicable heating and/or cooling systems. © §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) . 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. , EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:9 of 41 , Mandatory Measures Checklist: Residential, (Page 2 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk • (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum componentperformance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) (�(� '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in, conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 'Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar, radiation that can cause degradation of the material. [X] §.11'4: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot.*. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or " spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. [� §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures a§ 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. I- - 1 § 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or.one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 41 Computer Method Summary (Part 1 of 3) C -2R Wndrew Pierce Corporation 9/7/05 oject Title -Date Lot 10D -Hideaway La Quinta -Project Address Building Permit # H & H Air Conditioning (760) 340-3088 -Documentation Author Telephone Plan ChecF/Date" Computer Performance 15 Field ChecF/Date Compliance Mefho—lc (Package oromputer Climate zone Source Energy Use (kBtu/sf-yr) Space Heating Space Cooling Domestic Hot Water Totals Standard Design 4.49 37.69 4.63 46.81 Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name HVAC -1 MILJIVAC-2 & 3 'qWRVAC-4 VAC -5 Proposed Design . 4.62 34.76 5.79 45.17 6,153 Single Fam Detached (West) 255 deg 1.00 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume Roof 1,076 0.028 255 20 Wall 140 0.059 255 90 Wall 44 0.059 345 90 Wall 100 0.059 20 90 Wall 130 0.059 75 90. Wall 120 0.059 110 90 Wall 398 0.059 165 90 Wall 140 0.059 200 90 Roof 3,030 0.028 255 20 Wall 278 0.059 255 90 Door 43 0.387 255 90 Wall _ 312 0.059 290 90 Wall 134 0.059 345 90 Door _ 21 _ 0.387 345 90 Wall 487 0.059 20 90 Wall 168 0.059 75 90 Wall 422 0.059 •110 90 Wall 168 0.059 165 90 Wall 80 0.059 200 90 Roof 909 0.028 255 0 Wall 250 0.059 255 90 Wall _ 417 0.059 345 90 Wall 339 0.059 75 90 Wall 414 0.059 165 90 Roof 163 0.028 255 20 Wall 240 0.059 255 90 all _ 224 0.059 345 90 IW.@_l 154 0.059 75 90 Roof 737 0.028 255 20 1,076 3,03 1,310 737 Solar Gains Y/N Gompliance Margin -0.12 2.92 -1.16 1.64 0 Slab Floor Floor Construction Type: Raised Floor Total Fenestration Area: 18.7% Total Conditioned Volume: 65,509 Slab Floor Area: 5,244 # of Thermostat Vent Units Zone Type Type Hgt. Area 11,406 0.17 Slee iinng SleepLngStat 2 n/a 34,542 0.49 Living LivingStat 2 n/a 12,191 0.21 Sleeping SleepingStat 2 n/a 7,370 0.12 Sleeping SleepingStat 2 Na Form 3 Reference R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) Solid Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Solid Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2xl4.16) Location / Comments Owner's Suite Owner's Suite _ Owner's Suite _ Owner's Suite Owner's Suite Owner's Suite Owner's Suite Owner's Suite Great/Din/Kit/Office Great/Din/Kit/Office Great/Din/Kit/Office _ GreaUDin/Kit/Office _ Great/Din/Kit/Office .Great/Din/Kit/Off ice Great/Din/Kit/Office Great/Din/Kit/Office GreaUDin/Kit/Office Great/Din/Kit/Office Great/Din/Kit/Office Second Fir Guest Suite Second Fir Guest Suite Second Fir Guest Suite Second Flr Guest Suite _ Second Fir Guest Suite Guest Bedroom _ Guest Bedroom Guest Bedroom Guest Bedroom Casita Run Initiation Time: 09/01105 15:11:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 41 A- ' `t r X �r,R > l .' , J '�' rt ' ,i �' _ •- i`• l • _ 1,, - 1 •p. „ y 'n,'� - M� i 1 M ` � f• � T M 4 � A A4,pt x 6 r -rs- ``'• �' i"r f•+ k ' lv C>r -2R0. Smy'+puer,Method..0Ilk Ta rt 1'ofti3)Y , _ "`xndrew Pierce'Corporation 9/7/06%,; zr ` oject Title r • '`� " •" - tt, w - n ate r F r \ � r 'L'ot 10D -Hideaway La Qulnta: -Project Address ` 760 340-3088 ` " �H &�H•Air,Contlitioning " Documentafion Author f y : p (. Te ephone ,.'Computer Performance r ~` l` 15 -Compliance I Rff5d-(Package or Computer) . Climate Zone Source Energy Use, "Standard'- sProposed,' Compliance r� � -��� �' � ;,. _ , *� A , � , V, ..1. (kBtu/sf Yr)_':¢„RDesign • 'Design Y Margin'; r r s, , �" , f. s `` f ,space Heating �'i { 4.49 ' `r 'A.62 -0-12 Space Cooling ` _ k t 3769 r ,, 34 76,>> ' 1 ; . 2 92 ?,.. , ', :�463 79'D 5 =.16 ",Totals ,, 46 81 °,,�s 45.1 7 -f ' X Slab FloorGENEF TION • , , a'r. , .1 - Y w •f:'�i ,y .i ,. . 'k •y ` .: �, Y "i. �i Conditioned Floor'Area. '6,153 �:4 '' Floor Construction Type`. Raised Floor,; r" ,Building Type. 'Single Fam Detached '4r _', r', ;,� • 3. `� ' ,#n XTw otal.Fenestration Area: o Building Front Orientaion. (West)'255 :�� ifs} �,• j-'Number;of Dwelling Units:,,„1.00-x";- �� L;:' Total.Conditioned'Volume 65,509 r � .. ,. a >•i r y ^~. r . _ v , ,p. _ Number of Stories {1 �. ` c , ! Slab Floor Area 5,244 z .y ”*,�� ' e } �' t t ' - � '� i C - ` `�, � � a.. '. } r?• k?. i •sr- 4�'.' _ FS 4 .K +rM. *'� ,r.r + r- } � j �° .;. 5: 'BUILDING ZONE INFORMATION,.,'`, ti \' of:.lu of, +• .'+ `t' Thermostat'' 's Vents} Zone Name ' , : Floor Area ,' Volume Units'•' Zone.Type d .Type Hgt. Area ,r r ,.,�•.f e „, r _ .; . + r f. r `s ,� y k '' i .,, 'd` wr-5 dt � � Solar 'OPAQUE SURFACES Act. o Y Gains s. Type jArea� U -Fac` . Azm: • Tilt Y / N' . Form 3,Refe�ence ' `J,'.J ,,.'''Location'/ Comments'tir Wall 195x 3;0.059' "` 255 90' `1ry['❑ R-21 Wall (W.21.2x6.16)' E ° Casrta `' , Wall'., ` x•'•264 0.059 ` • 345 �: • 90 [ i �; R-21 Wall (W.21.2x6.16)' _+ Casrta r ,,Wall 67 "{ 0.059+ . ` 75 90 ` =;[X:•❑ R-21 Wall (W.21.2x6.16)' >: 9', Casita - ". * •�'t ,�`�: r `Wall 216 0.059,' 165 : 90. [X ❑ R-21 Wall (W.21.2x6.16) •Casita nit , J •..' s}ac T `.❑ ❑s. _ t Yf., r' -' �. _ .� r±r!.. ..Y ''+ .d J. 51 F vy r. ti;f�, .\ •t. - ,r'•❑r❑•?4,' -/�' 4-^ _ r l'`I - •ir•`a"';,t ?' �.: 1i +' l v •' r. i ` n.. +sa '. '❑❑, r ' ,�`s •-'. !� r.. -. � r J.y', �•+ IJ {.IF.'. S .J � , i. • ❑ ❑ , '+k �t — � ♦»^ i F ., . t L a e. � f � , F-1 F] - '.•h.• ' ,:c,�, ter. i,.�- '�,' ` �.,ri. .. \ r w �'- � '... 1, p'r'y- ❑i❑ .;- l r-' r - q, rT °i'• 1^y i - eS i�A,r / 1 r. .r .. f�4,, "S° ti .ic f« •_'❑ ❑ + - .. y 't ,- �i -r td ' - '•,.. "!'� 'x ,�. _.t ❑ ❑• L a `.• r a �' a ` ' t ❑ ❑ }' •' \� , 3= ,-. • ,. t.. b _. 17 t , ,�q.r j, .74 • LJ - nb R _'i f 4 + ❑.❑ +it >r , a t.t i+' ft; t +r �f,y r•. S- -.. , v - r r J h t x e w,• .! sl ;t,:4 t It 1j; Efl Run Initiation Time:, 09/01/0515:11 13 - Run Code: 41125612673 r4 3. EnergyPro 3.1 By fnergySoft s- User Number.' 5533 "Job Number: w: r s. Page:12 of 411 • 'L ,... �r .t r at' r .: ��- z' « ^./ w, �+ ,` ., tJ�,, ^• y�,w t ,� � r1 r3 � r}' .M- �_ Building Permit IF Plan Check/Date-,, P ' Field-Check/Date � ., ,, Source Energy Use, "Standard'- sProposed,' Compliance r� � -��� �' � ;,. _ , *� A , � , V, ..1. (kBtu/sf Yr)_':¢„RDesign • 'Design Y Margin'; r r s, , �" , f. s `` f ,space Heating �'i { 4.49 ' `r 'A.62 -0-12 Space Cooling ` _ k t 3769 r ,, 34 76,>> ' 1 ; . 2 92 ?,.. , ', :�463 79'D 5 =.16 ",Totals ,, 46 81 °,,�s 45.1 7 -f ' X Slab FloorGENEF TION • , , a'r. , .1 - Y w •f:'�i ,y .i ,. . 'k •y ` .: �, Y "i. �i Conditioned Floor'Area. '6,153 �:4 '' Floor Construction Type`. Raised Floor,; r" ,Building Type. 'Single Fam Detached '4r _', r', ;,� • 3. `� ' ,#n XTw otal.Fenestration Area: o Building Front Orientaion. (West)'255 :�� ifs} �,• j-'Number;of Dwelling Units:,,„1.00-x";- �� L;:' Total.Conditioned'Volume 65,509 r � .. ,. a >•i r y ^~. r . _ v , ,p. _ Number of Stories {1 �. ` c , ! Slab Floor Area 5,244 z .y ”*,�� ' e } �' t t ' - � '� i C - ` `�, � � a.. '. } r?• k?. i •sr- 4�'.' _ FS 4 .K +rM. *'� ,r.r + r- } � j �° .;. 5: 'BUILDING ZONE INFORMATION,.,'`, ti \' of:.lu of, +• .'+ `t' Thermostat'' 's Vents} Zone Name ' , : Floor Area ,' Volume Units'•' Zone.Type d .Type Hgt. Area ,r r ,.,�•.f e „, r _ .; . + r f. r `s ,� y k '' i .,, 'd` wr-5 dt � � Solar 'OPAQUE SURFACES Act. o Y Gains s. Type jArea� U -Fac` . Azm: • Tilt Y / N' . Form 3,Refe�ence ' `J,'.J ,,.'''Location'/ Comments'tir Wall 195x 3;0.059' "` 255 90' `1ry['❑ R-21 Wall (W.21.2x6.16)' E ° Casrta `' , Wall'., ` x•'•264 0.059 ` • 345 �: • 90 [ i �; R-21 Wall (W.21.2x6.16)' _+ Casrta r ,,Wall 67 "{ 0.059+ . ` 75 90 ` =;[X:•❑ R-21 Wall (W.21.2x6.16)' >: 9', Casita - ". * •�'t ,�`�: r `Wall 216 0.059,' 165 : 90. [X ❑ R-21 Wall (W.21.2x6.16) •Casita nit , J •..' s}ac T `.❑ ❑s. _ t Yf., r' -' �. _ .� r±r!.. ..Y ''+ .d J. 51 F vy r. ti;f�, .\ •t. - ,r'•❑r❑•?4,' -/�' 4-^ _ r l'`I - •ir•`a"';,t ?' �.: 1i +' l v •' r. i ` n.. +sa '. '❑❑, r ' ,�`s •-'. !� r.. -. � r J.y', �•+ IJ {.IF.'. S .J � , i. • ❑ ❑ , '+k �t — � ♦»^ i F ., . t L a e. � f � , F-1 F] - '.•h.• ' ,:c,�, ter. i,.�- '�,' ` �.,ri. .. \ r w �'- � '... 1, p'r'y- ❑i❑ .;- l r-' r - q, rT °i'• 1^y i - eS i�A,r / 1 r. .r .. f�4,, "S° ti .ic f« •_'❑ ❑ + - .. y 't ,- �i -r td ' - '•,.. "!'� 'x ,�. _.t ❑ ❑• L a `.• r a �' a ` ' t ❑ ❑ }' •' \� , 3= ,-. • ,. t.. b _. 17 t , ,�q.r j, .74 • LJ - nb R _'i f 4 + ❑.❑ +it >r , a t.t i+' ft; t +r �f,y r•. S- -.. , v - r r J h t x e w,• .! sl ;t,:4 t It 1j; Efl Run Initiation Time:, 09/01/0515:11 13 - Run Code: 41125612673 r4 3. EnergyPro 3.1 By fnergySoft s- User Number.' 5533 "Job Number: w: r s. Page:12 of 411 • 'L ,... �r .t r at' r .: ��- z' « ^./ w, �+ ,` ., tJ�,, ^• y�,w t ,� � r1 r3 � r}' .M- �_ + t •.t - ,,s, ~ . w ... • ' 1 � 17- h ".yr •+ a i. • i � • • •4 rt r K ' . 1 r `� '�„'•. j' f «d ,c- - '� t' •` v,` _ F• ' • . ' ! + k.'` '.... 1 s} y ' d r �•, yr U _ J' - .y a ♦�`w'G,vC -y.••ti .�, . s�R r� ""+ -[ r.. ' 3 -'� +"Y•_. •.- -, .V •�t '� y:3" 44 �-. .. "Computer Method Summary' ,F z s a i ndrew Pierce'Corporation _ ',y ; ' `'� 9/7/05., Tro)ect Title -Date -r• { -. • # ION SURFAG U- Act.`r�' !Glazing Type "' ' Location/ :Type ` V . Are"a Factor SHGC Azm. ,Tilt ti �; Comments r� a ° ;. f 1 ' Window Left (North ' 6.0 •,' 0.600 '0.46'-" i464,° 90' Double NonMtl Tinted Owner's Suite ? f 2 Window. Rear '(East) 15 0 0.600 0.46 110 , t 90 Double NonMtl -Tinted, • , Owner's Suite • , E A 3 •, Window _Rear ;: (East) ".15.0 0.540 0.46' 110' .90, Double NonMtl Tinted, .• Owner's Suite. 4^ Window, Rear • (East) 15.0 0.600 0.46 110 90 Double NonMtl Tinted ; Owner's Suite ' S -,Window .Rear (East) : 15.0 0.600 0.46 110 90 Double NonMtl Tinted Owner's Suite _ 6 - Window Righty (South) w 20.0 •0.550 0.46 .-165 90 Double NonMtl Tinted .;' ' Owner's Suite r 7 Window; Right (South),, .6.0 ." 0.600' 0.46. 165 " 90 Double NonMtl Tinted • . Owner's Suite." 8 " Window '.Right ' (South) ':', 6.0.0.600 0.600 0.46 .165 - •,90 Double NonMtl Tinted - , ; - ^, Owner's Suite, 9 Window Right '..; (South); ' . 15.0 0.600: 0.46 •.200 90'Double NonMtl Tinted. .xOwner's Suite n • . 10 . Window :Right. (South) ., 15.0 • 0.600 %'-0.46 200 -,90 Double NonMtl.Tintedi'_ Owner's Suite. 11.'Window ,Front.' (West), • 15.0 0.600 0.46 255; ,. 90 DoubleNonMtlTinted• r Great/Din/Kit/Officer 12 -Window Front . (West),,,, 15.0 70.600 0.46. " 255 C. '90'Double NonMtl Tinted GreaUDin/Kit/Office �;•y 13 Window ' Front est)"} `12 5 0.600 '0.46 255 90 Double NonMtl Tinted' - GreaUDin/KiUOffice =. ' • -i-4--'Window .Front .:; (West) 24 0 0.550 0.46 - 255 90 .Double NonMtl -Tinted ^,r +l • Great/Din/Kit/Office, • + .,i 15' Window Front . 25 -,,(West) �' • 12.5 0.600t '0.46 5 ;1,.90 Double NonMtl Tinted - +!,,Great/Din/Kit/Office 16Window -Front (West) _" 20.0 0.540 .0.46• 290,-'+-_90 Double NonMtl Tinted ­,Great/Din/Kit/Office,:. 17^ •Window. Front (West)y. 400 0.550 ,• •., 0.46 -.290 90. Double NonMtl Tinted Great/Din/Kit/Office 4 , tk 18 Window Front (West) 120.0 ,0.540 0.46 • ,,1290 . ; 90 :Double NonMtlTinted, Great/Din/Kit/Office w 19 Window: Left (North) -,, 15.0- 0.600 +0.46 345.• •90 Double NonMtl Tinted Great/Din/Kit/Office 20 •' Window..:, Left (North) • 40.0 0.550 0.46 345 �' 90 Double NonMtl Tinted r Great/Din/Kit/Office 21 ` Window Left. -(North) "; ,--6.0-, •0.600 .0.46 20t x 90; Double NonMtlnTinted . GreaUDin/KiUOffice •22• Window - •Left $.(North)f " t 6.0- 0.600 0.46' A20 .a. 90 Double NonMtl Tinted, GreaUDin/Kit/Office 23, Window • ,Left,,, .(North) - 6.0--0.6001 ' 0.46 20 90 Double NonMtl Tinted ;f :GreaUDin/KiUOffice 24 Window-, Left' (North),' 10.0 x„0.600 ' • 0.46 '+,20 90 Double NonMtl Tinted y +GreaUDin/Kit/Office ~d ' 25 `. Window, Left ,.• (North)' • ' 12 5 � . 0.600 0.46 20, 90 Double NonMtl Tinted "1. Great/Din/Kit/ '26, Window left (North)' 12.5 :0.600 0.46 20 , 90 Double NonMtl Tinted Great/Din/Kit/Office 7 Window .Rear •(East),, -T2.5 • -07600- 0-46 X75 ,.90 Double NonMtl Tinted , • 1 GreaUDin/KitlOffice r -} Window Rear •,<.(Easty•< -20..0 0.-550 ,F4:6 e_•110 ,✓_ 90_ DoubleNonMtl=Tinted _ GreaUDin/KiUOffice •e ` 29' Window Rear (East) 12.0 0.600 .0.46 •�; 410 :•. 90 Double NonMtl Tinted +-GreaUDin/KiUOffice • INTERIOR AND EXTERIOR SHADINGWindow " ` rOverhang �s Left Frn a ` Right Fin Exterior Sliade Type SHGC " '-Hgt: Wd ; '• Lena Hgti CExt. RExt r -Dist: Len. Hgi -Dist. Len., - Hgt. f 1 -Bug Screen �., .0.76 d~ Bug Screen 0.76 ' -'6.0: ,� 2.5 0.0 0.0 0.0 0.0 . Y' - ' Bug Screen , s 0.76 '+ 6.0 2.5 0.0 0.0 ; 0.0 0.0 4 4 : Bug Screen 4 •0.76 • .• , : , s' w Screen 0.76 Bug Screen' 0.76 . r y;, 7 Bug Screen' ~:rr 0.76" 8_ Bug Screen = 0:76- i 9 Bug Screen 0.76 6.0 2.5 0.0 , 0.0 0.0 t 0.0 ' 10 • Bug Screen', 0.76 •6.0,- 2.5 0.0` 0.0!' 0.0� 0.0 ,• r 11 Bug Screen � . +, s 67fi , 6-0 -r. 6.0 • T'o • 6.O,r.-0-0 17 Bug Screen . / -0.76 6.0 2.5 x 0.0 '-0.0 s 0.0 _ 0.0..; 13 ' Bug Screen 0-76 r i5.0 2.5 ` 0.0 0.0' .0.0` 0.0. -- ew• t+ .r��_ ,• X1BguScreen ;,, 0.76, .8-.0. 3.0'• 10-.0 , 10-.1 10.0 10.0 ug -Z.5, 145' -80--8-0 l ' 16 • Bug Screen- 0:76-. 8.0 2.5 0.0 0.0 0.0 • " 0.0 - , ~• ' - '' 17 . Bug Screen ,r 0.76 .x.18 Bug Screen - ^. - 0:76-y ', 8.0 -2-5 0-0 0 0 0.0 J 0 0 ' 19 Buggcreen = 0 7f -6:0 25 �.0 : 0:0_%. 0:0 X0-6 �. r 26, Bu_g - a' 0.7fi r ' 6:0 , 05 6:0 0:1 _CO 8:0 y, , _1; ,' , • r , ,,. 21' 'Bug Screen .- 0-7fi 4 a Q i ' +; `22. Bug Screen '� 0.76, ; a{. t '. ,• , ' 23 Bug Screen , 4 0.76 24 • Bug Screen 0.76' •;• �r 1 +•25 ., Bug Screen 5.0 2.5 0.0 ": -,0.0 _ 0.0. o.0 26 Bug Screen '� 0.76. 7 Bug Screen + 0.76 ' 5.0 2.5 0.0 0 0 0 0' ;0.0 -"' 8 w' Bug Screen: , 0.76 • 6.0 25 ' 0-0 ;,-Co r{; 0-0 ti ,0-0 S y } • . 29 Bug Screen �J v 0.76 :.. r • ,- w I �� 'Run Initiation Timei 09/01/05 15:11:13 1' Run Code: 1125612673 EnergyPro 3.1 , = By' EnergySoft User Number: 5533 ,, ti, Job Number ,, Page: 13 of 41 tV M 1-3 } t "...; , ?r'k'. .+•�+ `"`}. ', j 1, r�r s., " �.� t.y` Y i':$., ' �C`,i x � � ,. ra, ,, ♦ . • , 1�r - i „�_'�,� a' � e . � a i r: K Y -. �" S _ � +: ,+ I.1 ' � a K i .°t ,. � w r � '. -. 4 4 y>, K•p iA-. a a A� �• }� •C at `:. 'yc # 1� +` �"� ;��' r ` C.,a =..t, . r.,y r, �i �' t ' } Z'�r , ' '.e +�'•' �' .}i yy. `. ., :,.. _�' +'1 ti .•n".tiY 'a�.ir # rt. i x, a �.l ,.s .�' - s►�3 =.F 3c '�,� :",� �1 r'� '''Coimputer Method -Summary i 1 J i' 1 (Part,2{ofS' Y C=2R .• 41'R r., l i r,...,,. sr : ;"• , +J►)r_... ,,ti�rporation�ndrew PierceCo9/05 ro ect Ttle .l r 3 -Date �.. ti' s • , Act: Glazing Type f ,.. �. Location/ 3:.1 t a # Type'' ; `M ;'e� Area Factor, ;;SHGC•� ••Tilt' ,;, �.'' t Azrri: 'i.. �Comrrtents�' 30'- Window -Rear., (East �,� ' '24.0 ` 0.540.0.46 •' F 110 , 90lDo6ble NonMtl.Tinted' _r• dGre6t D" in/Kit/Office - " ,z Window- Rear (East) , ,12.0 0.600 "; ^, 0.46 110,1 1,r 90 Double NonMtl Tinted Great/Din/Kit/Office,'� f : 32 Window . Rear (East) �t -180.0 , • '-6--0.55 +' 0.46 ,;,;110 90 Double NonMtl Tinted s + r,=`: Great/Din/Kit/Office • w t 33,, Window -Right,.;°(South) L 12 5+�� 0.600 ,+- , 0.46 • 165 *- 90 Double NonMtl Tinted t. ,�Great/Din/Kit/Office•-, 1 l_0 �" 4 'r 34 `Window Right ;" (South). J ti.20.0 0.550 * 0.46' �' 200 r ,90,Double NonMtl,Tinted • '-t 'iGreat/Din/Kit/Office r'35 .Window •Front (West), r•. 6.0 0.600 `0.46 -'255 90'Double NonMtl Tinted. ..Second Fir Guest Suite 6-, 36 ,Window: Front , West ` 6.0 -.0.600 0.46'. -*`255 •".::90 Double NonMtl Tinted (West) " -, Second FIr,Guest Suite i c, 37 '.Window Front; .;(West) t�,. -.12.5 i0.600- . , 0.46 �"- ., .255 _ s- 90, Double NonMtl,Tinted�t­Second Fir Guest Suite b 4 .°•38 Window' Front L`: (West).: f(".• 12.5 0.600 +'0.46 it , 255 'i't90 Double NonMtl Tinted ' `+Second Fir Guest Suite a. } •39 Window,+Front" (West) •• 24.0 4 0.550 _+ ; .:0.46, J+,'255 !._90 Double NonMtl Tinted,. t ;;Second Fir Guest Suite =fi40 Window Front ,' West t - 40.0. 0.550 90 Double NonMtl Tinted Second Fir Guest Suite v l (West) , ,0.46 , ..:255 � �,' -.:,, t- 41 aWindow. _Left .,a (North) -10.0 - '0.600 .' •' 0.46 345 ; 90 • Double NonMtl Tinted -• 'Second Fir Guest Suite 42 Window "Left North ': .'`' 10.0', 0.600 -0.46 t"'s' 345 = ( )_ 90 ".DoubleNonMtlTinted., _.t.. dSecondFlrGuestSuite Y +43 - Window s?Left `* (North ;1" �e, '6.0` « 0.600 -'* .x:0.46 ;'',+.345: ` .90 Double NonMtl Tinted %Second Fir Guest Suite r i 44,T Window ~Left ; (North)'"" `t t;, 12.5 0.600 ; 0.46 345 90 'Double NonMtl,Tinted Second Fir Guest Suite 4 tr 45 :;Window ,Left 7 (North)12.5 0.600 ,x 0.53 4 .345 , „90 `Double NonMtl Tinted Default f Second Fir Guest Suite '•i 46 Window: Rear (East) s , 6.0 • 0.600 0.46' 75 t X90 Double NonMtl Tinted. .s «,;Second Fir Guest Suite At.` 47 Window;: Rear, ; , (East),�T, , 6.0 _,0.600;; ,., '0.46 i. 75 . • , 90,Double NonMtl Tinted �. �, _ , "a Second Fir Guest Suite L 48 ',Window -,Right :-�L.'(South),; , 20.0e, 0.550 0.46 r 165-,",.90 Double NonMtl Tinted- ^. Second Fir. Guest Suite 49 Window Right (South) 24.0„ 0.550 0.46• •.165 90 Double NonMtl Tinted _ +Second Fir Guest Suite �f<� 50 Window Right,,,(South) c .;10.0 -0.600 0.46 165 ",, 90cDouble NonMtl,Tinted 41.Second Fir Guest Suite yY S1 ¢ Window ',Left x-• (North), y' : 6.0 0.600 r`0.466,., -T!.345%,% 90 'Double NonMtl Tinted „� *��..Guest Bedroom 52 Window,, Rear c (East) ;+_ � .6.0 0.600 ;' -0.46 ++, ,'75 _s, 90 Double NonMtl.Tinted +' + Guest Bedroom ir., { 534 Window. Rear (East)!•f %i ' 20.0. k'0.540 0.46: pe 75' :,u 90 Double NonMtl Tinted .:e1.11 ;,kGuest Bedroom ; Window Rear Irl. (East). . 40.0 • : 0.550 }" : 0.46 , -75 90. Double NonMtl,Tinted . ` , ..:IGuest Bedroom,,..,:. � • +t ;55 " Window; Rear • r. ` (East) 20.0 0.540,a } _. 0.46 75. v 90 Double NonMtl Tinted, ;:Guest Bedroom 6 Window: Front. (West) ., r , 15 0 0-600. . s 0-46-_ -255. ,�-_ 9.0' Double NonMtl Torted x ,- , Xasita r 7 1Nindow Front: (Vilest) R T5 Or -0-600 0.46 -255-. t� 90cDou6le NonMtl Torted; is „ rt�Casita ,. 58 Window ,Front (West) '• ,15 0 0.540 '=r :0.46 255 : .90�Double NonMtl Tinted .,� NrCasita "+INTERIOR AND EXTERIOR SHADING c.. �,� r r � Window t k,Overhang , rt� Left Fin 't'', j i,,O , Right Fin •� ` �k3 # Exterior Shade Type 4' SHGC Hgt VVd- , , Len t Hgt LExt RExt: q= Dist.- en. Hgi , +Dist: Len.- t _HT <30 Bug Screen ,0.76 ••- ` r - + - �'` •c5 ft ,• ! 1 - r' r i.� I4,�+. 31 - Bug Screen 7 a. 0.76 ° XI V, •t. 32 Bug Screen -.',076r 100 ,18.0 .10.0,: _0.1 100., 100 ,; ati s ,w ,, 1 14 a .33, Bug Screen , ` t r rn, , r 0 76 't= t ., , y , r'' ; xa. fi r� �t ' s ' -A 34` Bug Screen Y � .c,:,.M ,x'076 1',8.0 � 25,.-:' 10.03' 01 10.0 .100 .cr 35 ;Bug Screen' fi ' 10.76 K z, 30 2.0 ,` r» 4.01 01 , 4.0 40 ,� 36 '-'Bug Screen's r076ti + 30` +20' 40 01 40 ' X40 c •37 Bug Screen, s . +_ 076 , :1h . 5 , *' sty s r 3i- s yrs« �� ;• r 38, ,'; Bug Screen 0 76" 39 , Bug Screen _+ 0.76 ', �e'r n ► , j 40 }.Bug Screen x ,, . U. 76 , , y { F:. J f j. } F y .• , K' e� ` 41•+ ;BugScreen ya _ � u 42' Bug Screen , y 7 0 76 r ', fi. !, �1 . i 1.. L! 7 i -r o `f� *- yk=�• e''r 43 Bug Screen; .t } O 76 a • ; a✓ ry s E♦ , !„, T i ` z h $^ 44 Bug Screen r,y.�;7, 076 45 Bug Screen � ,^ � 076 sr-" n' 1:,4� •Y +� + t ��� �� � � f ti t r 46 Bug Screen _ r ' 0.76 47 Bug Screen r4 , r,: •076 48, Bug Screen.w f 076 80�;=2.5 +; 40 x„01' 40 40,,� 7.- -• * ••A • _. 49 ` Bug.Screen c s , 0 76 i. s 8-0 3-0 4.0 0:-4 50:- Bug Screen E -0.76 .45.0° .2.0 i.' 4.0;. '0.1.• 4.0 F 4.0 t+ r".,., R , �• w . s Bug Screen 0.76 a 0') 76Bug Screen s .• x a r'3y'".i076'-6-3f.",Bug Screen_3 t a <, aF r p 4 n ,' T :3 p si-• , 54 - Bug Screen ,t, 0.76 r : 55k Bug Screen'0 76 t'� , .'�•� t , ,1••- ;, _ , ` ., t• a e �; , ...+ h �o r e , 6 Bug Screen 0 76 1" �. 7 Bug Screen '4. 1 0.76 58 '` Bug Screen tw., i 0.764^ Y 'lv ltt, { s .., -_r at' ' - V'r EnerggPro 3 1 . *By Ene gySoft r Run IUseaNmber 553 on Time: 09/01/05 15:11 13 Job N m berCod:,.1125612673 ;H y.h Page:14 of 41 y j ter•' : `y fir 4� , - 4f~ �' K'� t.' �� �,srt� z' k._ y ' ` j !.(• ��6 �Y ,tir., t, + `,� `fl 3•-�r �� ,a.ti' � s�,..:� � - f� "`q. 4 •- � f F"`i , a;; '� �,' "- • ,k '$, S i• r a S a^. +hj4 - ,�.: •a• ,Ao - v ir" a�,t + "x :�: '� -...f WSJ N.H4 a "�.•. 3�; i '� :, l f �"i . ,f• '1 ' .rt-tl`�"k` 7 1F� Y q 4" 'In A. 0 AJy' 14, >-A -F Pti A , ­tbr McithodSUmmar (Pa..rt 2 C-2Rw ," :-Complu y,.. Mfoject hdeewpierce'Corporationw 9/7/05 TFtleDate, A A FF-INESTRATILIN SURFACES y .Glazing 7pe,,* 7, Location/ U- `FactoC--!i, 4 # Type Area SHGC ,,x1PAzm.1' Tilt', 59' Wifncl w', Left (North 12.0 0.600 0 .46 345 96 Double NonMtl Tinted' rA;�'�'="'Casita l 60 Window Left, (North) 12.0 0.600 0.46 34590;'Double NonMtl Tinted Casita 61,, Window Left (North) • ;12 0 0.600r 0.46 345 NonMtl Tinted .90 Double Non 'Casita �.,,,62 ,Window 'Rear+ sa;(East)4,, 1-wV,12.0-,'-0.600 0.46 i 75,1 , -90 Double NonMtl Tinted, -.- Casita 3 4 -.Window- Rear, - (East) -vis 12.0 r '14 � 0.600 -:,-,0.46 7 1L 75 90 Double NonMtl,Tinted. Casita.' - . 464 ,Window, Rear (East) •24 0 e 0.550 0.46,, 75 --90, Double NonMtl,Tinted Casita .365'. Window,?Right .,(South) 12.5- 0.600 0.46 165 90 Double NonMtl Tinted Casita �.%C ",z�--"Winclow Right., (South) ----6. 0 0.600 .0.46 Double NonMtl Tinted ,Casita. -:. 66 165 Casita Is . % 67 Window �Right (South)',. 6.0 0.600 0.46 --1165 90 Double NonMtl Tintecli� Z A 77 3, 48 'r p, s V!�v AT, T, 4; A, L Ie 4. 4"1 : A c�:j�4 . I � ,, , -f i , - - '. 1" '.'9 h i -t.. , '. . ;r { . J 16 Z 7 0 INTERIOR AND EXTERIOR SHADING 6W t �'L&ft Fin z, -,..Wind verhang Right a T L -e -n-. R Tt-. 7 C E -xt 7%- R E -xt. -Dist.,Len.F�,. gt.. -1D0t-.- Ce-nT--, % Exteriol�"S�' de' pe' SHGC-W Hjjt. -59F- Bug Screen U.76 go-.:- Bug Screen 7--.,.�. 0.76 .t - , , 7 J�;,�- 61 Bug Screen .7, 62 Bug Screen `63 -ILI !Bug Screen 0.76, -6.0 2.0 -ACI;. 0.0 0.0, 0.0 .4 0.76 .0 :"Bug Screen 8.01f. of 0.1, 4.0 �4.0 Bug Screen 7 e., Y.,x -re 7-17 Bug Screen Z6 A V ,Bug Screen-. f 0- ;77. I *A 7 !4 7'Z 1 o. . v VI - 7 A 4- j 7 1 P7 & 4 -T, A": =,7 1,f t% % p tj , �Ik 4:� Run 09/01/05 15:11.13' Ru Cod ^M,A �R r; 42�,1125612673 t 3.1 , By EnergySoftUser Number. 5533 �Job Number:- pa'ge:1 5 of.41 64 > o T r JL. •v:* µ'Vi. �y tiY e�• e• , ;. -':} ••; _ ^. •_ .�'F �F •�•,.f r' " _q,ti r,., tai .T~�� •i. •i. ti+t e j•. e, -,. Computer Method,, Summary "Y"� • (P,art.3"of 3j_ :4 C-2R' ., t �. HAbect ndrew Pierce-Corporation , a #•� ojTitle , Date r .,.., ,�, �•H l• j s = • .�, -,THERMAL MASS FOR HIGH MASS DESIGN' Asea Thick. Heats +�� - Inside Location j -Type ,'' (sf) -(in.) .Cap. Cond. Form 3 Reference R-Val. 'Comments C "Concrete, Heavyweight : 794 • 3_50 28, ' 0_98 n/a 2 Owner's Suite / Slab on Grade C� oncrete, Heavyweight. 282.'t 3_50 28 ' 0.98 n/a ` r .'a: u 0 .Owner's Suite / Slab on Grade { r Concrete; Heavyweight 210,•- 3,50 ' 28 A', 0.98 n/a` - i t "'7 }' .2; . GreaUDin/Kit/Office/ Slab on Grade i Y Concrete, Heavyweight ° 2,820i- 3.50. ° ".. 28 0.98. n/a 0' - Great/Din/Kit/Office / Slab on Grade.- Concrete, Heavyweight -..303 } 3.50;. 28 0.98 n/a "', ' 2 Guest Bedroom / Slab on Grade •+ PERIMETER LOSSES' •rr .` F2 Insulation . r t e.,• . !� J x a Ty"pe ".' t Len.gth .Factor 'R-Val. Depth I Location / Comments..,1 +' Slab Perimeter, 82'1,0.76 0.0 =0 Owner's Suite Slab Perimeter �. .38 ` • 0,76 a 0.0 0 Owner's Suite Y' �`' r - i • Y Slab Perimeter 40 0,76 '_0.0 0 Great/Din/Kit/Office- e . Slab Perimeter325 0.76 0.0 0 Great/Din/Kit/Office. -Slab Perimeter 33 0.7ti 0.0,' 0 Guest Bedroom' HVAC SYSTEMS - �'• A ; f, «i y '� , . f 4 ♦~ ra �HeatingEquipment.. Minimum Distribution Type - i ' ,3 i •• ' ti �. Type (furnace, heat Y Efficiency and Location: , IDuct . "Thermostat Location pump, etc.) �', (AFUE/HSP.F)(ducts/attic; etc.) R-Value�,Type, Comments - .�' Central Furnace' 80%'AFUE iDucts in Attic 4.2 Setback HVAC-1 a ' Central Furnace ,F, Y 8001.AFUE •'Ducts in Attic r j 4.2 Setback HVAC-2 & 3 k " Central Furnace . =• 80%AFUE: Ductsin'Attic4.2 • Setback HVAC 4 •, Central Furnace 0 • 80%AFUE' Ducts in Attic' • '4.2 Setback, HVAC-5 L > 1Wydronic Piping` Pipe Pipe' ,Insul • System Name 1. Length Diameter Thick. , ''' S ''' ' tf xa` Cooling Equipment. A Minimum M1 Ducta ;rType (air conditioner, Efficiency Location ,Duct Thermostat - r Location / t',~ ,heat pump, evap. cooling), 1„ '.(SEER) ;(attic, etc,) +;:' �R-Value Type Comments °'+; ; 11-1' ., I ' — - Split Air Conditioner- x,.13.0 SEER Ducts in Attic � ,t . 4.2 Setback HVAC-1 Split Air Conditioner 1 13,0 SEER, Ducts in Attic 4.2 ,e r Setback . ' , HVAC-2 &3 Split Air Conditioner13.0 SEER Ducts in Attic , 4.2 ; ,:_ Setback HVAC-4 • Split Air Conditioner ' 13.0 SEER Ducts in Attic ' . 4.2 Setback- HVAC-5 WATER HEATING SYSTEMS t • , ' r° Rated/ . Tank Energy Fact, ' 1 Tank Insul. Water Heater `r 'c. Water Heater ' Distribution y ' # in „Input -Cap. .6r..Recovery .Standby 'R-Value( y , System Name _' ` Type "Type_ ,..>Syst. (Btu/hr);; (gal) Efficiency Loss (%) s 'Ext. 'AMERICAN CG52-75T75-4N;* ' ''' Large Gas _ r ' �1 '75,100. .s 75 %0.79" 0.0244 0.0 ':AMERICAN CG52-75T754N"' '.Large Gas ,1 75,100 75' :.0:79 ', 0.0244 0.0 .' 1 For small gas storage'(rated input <= 75000 Btu/hr); electric resistance and heat pump water heaters, list energy factor. + For large gas storage water, heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency.and Standby Loss. -, -For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency: Y REMARKS .t Run Initiation Time: 09/01/05 15 11:13 ,; Run Code:: 1125612673 EnergyPro 3.1, • By EnergySoft . + User Number: 5533 > 4 Job Number: Page: 16 of 41 : Af • r'r .' t.', f q� � F .� `x, f r . ti :. } r '�, . ,l �,: � � rt ..;. `j, � A ' -. ,' ..� " -`�, f ::i .s s:;;i'.. kf 4 "A "p U M od Su'mi'marty.,x--, -2R. •Comp' Computer. 6th "(Pa rt., 3'of `3 `AWhdre to i4 Pie li:6,,Corporation 9/7 5, "IJ 41 Nate .Wroj t-1 me 'THERMAL MASS FOR HIGH MASS bESIGN I AreaThickHeat " Inside ide'', Location 7 T eVe(in' Cap ConaFornSR4f ren�e, _,:R'Val."Comm6ntS,, Concrete, Heavyweight 98 3.50 .28, 0.98.n/a- 0 ,:,-Guest Bedroom Slab on Grade ' Concrete, Heavyweight 399 3.50 = '.t 28 - 0.98 n/a: 2, Casita Slab on Grade Concrete; Heavyweight" <z 338 4. 3.56 28 r'70.98-n/a 0 Casita Slab on Grade L A 4V A PERIMETER LOSSES F2' )ln'sulationt',, 7r, Type t -pment§, . Factor R -Val:,' .Depth o r .Length Location'/,,Comments, n ,Cc�r Slab Perimeter. 34 0.76- 0 Guest Bedroom J, Slab Perimeter 62 0.76 OW CasiW -§-Iab Perimeter, ,56 -';1�0:::7::6 0.0 io xCasita '- If 4-t Y- 4F HVAC SYSTEMS-'-. �16 t Heating, Equipment' Minimum. D Mi ribution Type',":, T06 (furnace' heat' Efficiency, "and L&cation%.-­! Duct -Thermostat' Location um etc (AFU E/HSIPF)(ducts/attiO etc.), R -,Value-' Tyr)e;%L,, Comments L 17 4 %J. .Iwydronic Pip'in'g -'t,' ' Pipe Pipe ,' Instil A Diameter Thick System NameLength 4 , . 6 4 .1 Cooling Equipmen`t' -Minimums , Duct Type (air condition'er,. �Efficiency Location '}a Thermostat '*:_L o'cation/'-"- heat p mp, evap. cooling)N. .',.�"(SEER) (attic, etc,) R -Value •TyRe,,.,, Comments , fi 4 2 fk 4C T, 4 WATER HEATING SYSTEMS :Tank Energy,Fact' T- t Rated, Tank Instil s d I .,Wat4, Heater .,'Watel� Heater '6is'tribution in eiripLit - 4 Cap.' "AL, ap. 'br Recovery� Standby. R-Valuo System Narne,, "r,• Type Type -,SYS �_Loss t. (Btu/h r) (gal)L' xt., t VV, 4- 4 p j. A Ir" For small gas storage (rated input <= 75000 Btu/hr), electric resistan'c'e and heat'pump water.heaters, list energy factor. For.large gas storage water heaters (rated input > 75000 BtU/hr),'Iist Rated lnput,�Recovery Efficiency and Standby Loss. ..;r For instantaneous gas water heiterrs,l list Rated Input and Recovery Efficiency. REMARKS r, AAA Run Initiation Tihii. 09/01/0 .15:11:13 Run Code: c1125612673 V By Energysoft User Number: '5533 ob Number: Peg e717 of 41, L Computer Method Summary (Addendum) C -2R �ndrew Pierce Corporation 9/7/05 'Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 794 sgft Covered Slab Floor, 3.50" thick at Owner's Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 282 sgft Exposed Slab Floor, 3.50" thick at Owner's Suite The HVAC System "HVAC -2 & 3" must meet all CEC Criteria fora Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2 & 3" includes credit for a Radiant Barrier installed per section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 210 sgft Covered Slab Floor, 3.50" thick at Great/Dining/Kitchen/Offic HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2820 sgft Exposed Slab Floor, 3.50" thick at Great/Dining/Kitchen/Off ii e The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 303 sgft Covered Slab Floor, 3.50" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 98 sgft Exposed Slab Floor, 3.50" thick at Guest Bedroom The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the feel verification and diagnostic testing of these measures on a form CF -6R. •fhe an ie ld FIVAC system - includes Refrigerant Charge an i ow Credit ora ce i ie rater mus provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 & 3" includes Refrigerant Charge and Airflow_ Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC-4"includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must provide, verifification of the TXV, or measure the Refrigerant Charge and Airflow. he FIVAC System includes Retrigerant Charge and Airtlow Credit (ora certified HtKb rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 09/01105 un Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:18 of 41 Computer Method Summary (Addendum)' C -2R ndrew Pierce Corporation 9/7/05 ro/ect Title Date s Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies -,...,............, ......y... Y ja..a 111-.vn onu .,-1-11—tgVll auunnueu. Plan Field The HVAC System"HVAC-5" includes credit for a, Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 399 sgft Covered Slab Floor,,3.50" thick at Casita HIGH MASS Design(see C -2R),- Verify Thermal Mass: 338 sgft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS, provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field Run InitiationTime: 05 1511:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 ` Job Number: Rage: 19 of 41 r F , Run InitiationTime: 05 1511:13 Run Code: 1125612673 EnergyPro 3.1 By EnergySoft User Number: 5533 ` Job Number: Rage: 19 of 41 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY FP ROJECT NAME DATE Andrew Pierce Corporation 9/7/05 YSTEM NAMEFLOOR AREA HVAC -1 1,076 Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sqft) 66.0 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 43.7 Total Output (sgft/Ton) 274.7 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.49 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 26.0 of OutsAir 0 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK"COIL HTG. PEAK CFM Sensible Latent CFM Sensible 512 10,496 0 293 12,754 0 525 638 0 0 0 0 0 0 0 0 0 525 638 11,546 14,030 HVAC EQUIPMENT SELECTION CARRIER 38HDC048 33,838 5,444 71,000 Total Adjusted System Output 33,838 5,444 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2pm Jan 12 am 69.6 OF 69.6 of ,-, 111.3 of Supply Fan Heating Coil 1600 cfm ures at I Ime �, Return Air Ducts 14 Supply Air Ducts I 110.9 of ROOMS 70.0 of f-UULINU ara I tivl VbTL rIKUMt I KIcS . (Airstream I emperatures at I Ime of cooling Peak) 111.0 / 77.6 OF 74.3 160.9 OF 74.3 l 60.9 OF 54.4 / 53.4 OF Supply Air Ducts Outside Air t� ; 0 cfm Supply Fan Cooling Coil 54.7 / 53.5 of 1600 cfm 46.8% R.H. ROOMS 74.3 160.9 of 74.0 160.7 of Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 20 of 41, y. i 3�_ 1F _ s�.a `i• I I l ` • �,.l l ,. ly - ,*•.• • . , ') 4�r ' tf�� •� ^ K, r } 'r'' `- i4;_ � k. 1: ' r ` . ; ! � •� ... �'- • 4, r•.Y r° s. +„ �f r�, y - '`f /,W _ � : j Y':j•. I > c< { � �. t�r , L r}.s , HVAC;SYSTEM HEATING AND COOLING. LOADS. SUMMARY; ,>" y', :': �';• * Oil OJECT NAME ix a w s. t `r . + DATE 1 { Andrew Pierce Corporation`s ;'. rt:..*.� a -9/7/05:- f YSTEM NAME y • '� t., t r, FLOOR AREA 13•+ ► �'' + HVAC -2 & 3 j • .i '-"'� , . - k �''' �r ._:. L+ + t '-3,030 - �ENGINEERING,CHECKS'- ? =� SYSTEMLOAD ;. • �" Number of.Systems ;t { '; rj, ' 2 ' 1 ' 'g+ . �• Heating System r, F. •T�' Output per Systerri• `�' ? 89,000 Total;RoomiLoads 1,641;' 33,081 .c '� , 0 927 40,304 ", 4 Af. Total Output (Btuh),. 178,000 ^ Return Vented Lighting 0 ' Output Btuh/s ft i' "-58.7 ,:r s e+ p ( q ) Return Air Ducts 1;654 ;:, r ,� 2,015 Cooling Systems =,< <, . ,� . Return;Fan �„ • o A:.J _� o I. - ,, Ventilation . o ,Output perSystem i. ., � , f 58,000 � f' , • .o.y 0 ,� Total Output Btuh ' 116,000 Su I Fan ' ' 1 P ( )' pP Y . ^ 0 „' r �' 0 '^ > r., , t �4.,. iw Total Output Tons r X9.7 f r 4 H_ AF P ( )• " ' - , Supply Air Ducts -: 1s54 t �`;- ,•, ,°, 3 1:2,015 - ••+,t;�;- j ' . Total Output (Btuh/sqft) s.'4 38.3 ' '• ` AL D s • _� �" r -�' TOT -SYSTEM LOA _ o, �q4 • 36,389 s ,335 Total Output (sgft/Ton)' ":� 4 313.4 Air System" ` HVAC EQUIPMENT SELECTION CFM per. System t� v ,2,000 CARRIER 3BHDC060 ��_ r f ' ' y 83 921 13,268 'n 178,000 i,,.'Airflow (cfm) r : x:4,000 «^ Ffi, k "? xJ 'Airflow (cfm/sgft) . 1'.32 .' ; ' �? ., l ,�' ' 0 ','Airf.413.8 y �� • Outside Air (%) ` `,Total Adjusted System Output - 1.t 3 0.0 ( 83,921 13 2681 x178,000 r y? +' - (Adjusted for Peak Design Conditions) } Outside Air (cfm/sgft) f 0.00 TIME OF SYSTEM PEAK t `� �` y « Aug 2 pm I " Jan 12 am 4 ,� 'A A" Note:.values above given at ARI conditions ` (Airstream Temperatures a,. ime o HeatingPeak). :max -. 260°F, is .69.5oF` " `69.5°F 111:3°F •a!Y'� ��.., ,�= t. a ±.'`+, r. y,e Supply Air Ducts Outside Air 0 cfm ; Y i �.: ► 1, } Supply Fan Heating Coil, ? "1 ry ��: P' r^ F ,, 3 4000 cfm �� '�., < f { ` 109 r r r- ,. i.. ;r~ =; _ROOMS r r, x a • ✓ t: ' ,e Y K • 0 of 70. •, �. 69 5 r x «Return Air. DuctS' _� •','Y •1 Ii �_ .1. • _" h � d ' �wi. '. 1 -' r . _ - . .Yi _.. t-. ,� �' � f '.,.+'•� . _. L (Airstream empera ures at, ime o oo mg.Peak) r - r 111.6776oF� W 74.4/61.0oF'; 74.'4/61.0 OF 54.7/53.6of .' ,, ' r s u w }� + !t z v a Supply Air Ducts Outside Air' {' V�6 Y • «, S • 1N r , F`' w I l 0 cfm L, a „ Supply Fan x ;` 3 a `, 4 of . } + pp Y Cooling Coil. c 55.1 / 53.8 { ^ ,r ^: 't- 4000 cfm r l• � � ROOMS r 13 j f v; r. . i {� ;: t 47.2%RH+ 1 o :h c « ° �' a - 'i' ✓.* +��e 74 0 / 60.9 of i •" 74:4 161.0 F .« * Return Air Ducts' ` r EnergyP o 3.1 , •'': By EnergySoftUser Number: '5533 r j „ t;'Job Number:- ; ,Page: 21 of 41'% Ai •i I , tti. Wit,« r �' } ..r - • ,- , 1 ' t = y f'r- }, i,, `u'• f - :� 1 •' ,D t,.i rY f, ;., , F - 0.— All f • .{ .r rl�� 1 _ j,. _ .. �'� , f .. 'r t '�1i. t y,Y . - yj , + 1 '1• - } A ' , Ip - * •j ' .. .#^... .i �','�,:,. �..f5 .t s +r'✓Y .+ _A" ,t.s�. 'COIL COOLING'PEAK'-;' COIL HTG.-PEAK CFM `Sensible -: Latent t CFM : Sensible •{• <^-.f � 'Y -ice. �S •zrii� r �' L-ql a� 'c � -; f�, '��..i`:E • * t 1. ;+ � .� -,r 7 y, ir'� ;'� . � { S ., - r w J t 7'�' • : ;" j + `~ ' ,- ,+. 'a � � ' l �;` r' r� F. 4 t+, - •� •�' ti. -! �r. •. - ,t yt „y ..�.. �^ l� • vl rt_ •G' # . ,gin , T 47,000 .= Total Output (Btuh)�' " �' x' > 47,000 " HVAC SYSTEM HE' TING •AND COOLING10AD&SUMMARY> • a 35.9 . 334.5 Air Systems - T � . Airflow (cfm) .. _. Airflow (cfm/sgft) - 41.22 (" Airflow (cfmrron)r' , 4 ', ' x r ROJECT NAME . -, Y _� 1 rt 0.0 e, DATES "0.00 ♦ Andrew Pierce. Corporation M r 7, ,0 9/7/05 �'t t ,' T NAME . ♦ w + SrY` t, e: k EA FLOOR AR ,;� �. �, -HVAC -4 O rt _ f31 •'i, - ENGINEERING CHECKS • JrSYSTEM. LOAD ,., " 1'; t�. i ' K .r y,• 1; Number of Systems 1 Heating System! • ,` tt Output per System •• , sy'� �' t,. •+ .71,000 Total Output (Btuh) t ': ` +71,000 Output (Btuh/sgft) ':� 3 Cooling System' Output per System i ry +; 47,000 .= Total Output (Btuh)�' " �' x' > 47,000 .Total Output (Tons) 3.9 Total Output (Btuh/sgft) .` a 35.9 'Total Output (sqf tTon) t �, 334.5 Air Systems - T ' CFM perSystem` 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) - 41.22 (" Airflow (cfmrron)r' , 4 ', ' x r 408.5 I Outside Air (%) ''' . w R 0.0 e, `Outside Air.(cfril/sgft) "0.00 COIL •COOLING PEAK COIL HTG.,PEAK CFMT Sensible +'Latent' CFM ; f Sensible -,,Total Roomlco ds Return Vented Lighting F ` aReturn+Air Ducts F '14 Return Fang 'Ventilation' Sup'ply Fan ' • t 4" ft�Supply Air Ducts 946 - 18,941 ' 0 't`, 401 ' ♦ *1;17,365 ,y 0 , r� ':� 3 ! ti �•' 947 =,'868I 0 `T 0 �- s a, f 7, ,0 868 rfr • . �?r ! Y 'TOTAL SYSTEM LOAD , 20,835 0 ; ' "; 19,101 HVAC, EQUIPMENT. SELECTION CARRIER 38HDC048h• 33,940 ` 5,452 •tom �, ,yJ : T t - ''♦ ':� 3 71,000 ,Total Adjusted System Output M.(Adjusted for Peak Design Conditions) , 33,940 5 452 71,000 . �,• r 'y TIME OF SYSTEM PEAK `. Aug 2 pm y-� "Jan 12-a ml Note: values above given at ARI conditions i.. ' ; a tt�• 4�a+ •� ,]r HEATINGSYSTEMPSYCHMMKIU5 (Airstream -empera ures at Time of Heating Peak),, ,•_ _ � • L .,' 26.0 OF �+^ :, �' 69.5 OF , : 69.5 OF 111,2 °F •' - ra ^• w Supply Air Ducts ♦" ., O • _ a , ; t Outside Air �.�. O • * Sic• 0cfm ,., y .. , .;• l a t +- 'r 'Supply Fan` t 'Heating Cotl ] �� .1600 cfrn,' -ROOMS' . :r �, :r a,,,. , f, • - ' * i 'c' ' to t � . --.. a' • '. -rtit , ¢ , .: ! t int. � �_, ' X• + * +fl,. ��' � `• w r _ r i * . �', a ;i r v ❑..; y rx + ^ 70.0 °F.: Return Air,Ducts, ' yµ irs ream. empera ures at Time ot cooling Peak).> • r: t'' S ' `M. -4 � k Y• t s OF. i" E' 111:0 77.6 7 . 74.6 61..-0 ofr 5S4 .4:6 6- ,�yy,.., _ r • . F t' • ,, v r, •r , �, - .a- p�-? J /53.5 OF;'+ • ', f� 4, +,t.. �, +�. Supply Air Ducts Outside Air c.. f K . •,' 4 O cfm S . • s +: ," Supply Fan" Cooling Coil' if �' a ] A ;; �,•� x,55 2 l 53 8 °F' 1600 cfmof ' ROOMS 4 r.'. 47.1.° RH . 740!60.8 °F 74.6'161 0: F e ` ♦ ( 4.t �, iF ! ,R ''} ` . `' .� s f �:: '� �`, 1% � T �"I •_ls `}• ��,Ir. ' ` r Return Air Ducts' } E' • A r ' ^ , e •Ener Pro 3.1'; BY EnergySoft Soft 'User Number: 5533 >- Job Number: . +. j<, "Page:22 of 41 9Y i °# - � • . Nom, - . , ' � " i r ��„ t, . r ' � - + - a"r• y+ k G-.� 1°E' f ..F ? • +r+s �• w k ° •�+' +'�� ij .'�': �. r3 'Lr � " r-+' ' •'� r£t,f. � � y: ,4a �yt��+,�`f'. e •a,++L ° .Y "•., rrw �' .',;tSy .. • '�;''-. Lt+ i ► ' .- �.v t,• � 4'{',i t. 'T r ,�. •,�`e{ ,.�. � + y.. '3. ,. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Andrew Pierce Corporation HVAC -5 Number of Systems 1 Heating System Output per System 54,000 Total Output (Btuh) 54,000 Output (Btuh/sgft) 73.3 Cooling System Output per System 29,400 Total Output (Btuh) 29,400 Total Output (Tons) 2.5 Total Output (Btuh/sgft) 39.9 Total Output (sgft/Ton) 300.8 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.36 Airflow (cfmrron) 408.2 IOutside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF Outside A 0 cfm 69.4 of 69.4 OF 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 9/7/05 FLOOR AREA 737 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 444 9,737 0 228 12,051 0 487 603 0 0 0 0 0 0 0 0 0 487 603 10,711 0 13,256 CARRIER 38HDC030 22,912 1,369 54,000 Total Adjusted System Output 22,912 1,369 54,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm ,tan 12 am earn I empera ures at Time of Heating ea 120.2 of Supply Fan Heating Coil 1000 cfm Supply Air Ducts 119.6 of ROOMS j 70.0 of Return Air Ducts I F;UULINU JYJ I t_M VbY1;NKUMt I KII;J (Airstream I emperatures at I Ime OT L;ooling veaK) 111.0 / 77.6 of 74.5160.10F 74.5 / 60.1 of 52.9 / 51.8 of Supply Air Ducts Outside Aird 0 cfm Supply Fan Cooling Coil 53.4152.0 of 1000 cfm 43.9% R.H. ROOMS 74.5 / 60.1 of 74.0 59.9 OF �, Return Air Ducts %4 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:23 of 41 ROOM LOAD SUMMARY ROJECT NAME Andrew Pierce Corporation DATE 9/7/05 YSTEM NAME HVAC -1 FLOOR AREA 1,076 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Owner's Suite Owner's Suite 1 512 10,496 0 512 10,496 0 293 12,754 'PAGE TOTAL 1512 10,496 "I 293 12;754 TOTAL 512 10,496 0 293 12,754 EnergyPro 3.1, By EnergySoft User Number: 5533 Job Number: Page:24 of 41 1 4 FD ROJECT NAME DATE _Andrew Pierce Corporation 9/7/05 YSTEM NAME FLOOR AREA HVAC -2 & 3 3,030 IROOM r= SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Great/Din/Kit/Office rea inmg i c en ice 1 1,641 33,081 0 1,641 33,081 0 927 40,304 t ' PAGE TOTAL 1,641 33,081 0 927 40,304 TOTAL 1,641 33,081 0 927 40,304 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:25 of 41 I .1 ROOM LOAD SUMMARY ROJECT NAME Andrew Pierce Corporation DATE 9/7/05 YSTEM NAME HVAC -4 FLOOR AREA 1,310 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Second Fir Guest Suite Second r Guest Suite 1 666 13,333 0 666 13,333 0 239 10;337 Guest Bedroom ues a room 1 280 5,607 0 280 5,607 0 162 7,028 PAGE TOTAL 946 18,941 0 401 17,365 TOTAL 1 946 18,941 0 401 17,365 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:26 of 41 , l 4 1 1 J l I 1 f 1 1 f f ROOM LOAD SUMMARY ROJECT NAME Andrew Pierce Corporation DATE 9/7/05 STEM NAME HVAC -5 FLOOR AREA 737 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita asi a 1 444 9,737 0 444 9,737 0 228 12,051 PAGE TOTAL 1 444 9,737 F 0 228 12,051 TOTAL 1 444 9,737 0 228 12,051 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:27 of 41 R-38 Roof (R.38.2x14.16)' R-21.Wall (W.21'S6A6)' Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Slab-0;-Gracle­r'..-­'• 0 27: P4, 7 L % + -0.0280 1,326 �11 "06.0 X C X, I 1,072.0 X 0.0592 X -44.0 2,793 93.0 0.6000 X 44.0 2,455 115.0 0.6400 4,.X 1 -44.0 356 t to ' 20.0 ,,'X' :i0.5500 'X -i Jf 44.0 484 - I - periniet6r 120.0 x 444.5 .5,340 X x Q_ - x X- X'. x x 4 x x - x X x X, 7, x 4 X xi x I x x x X x + X, x A X X.} x x X X, _x x 4 x x x X LW Lit v ,X 'x- x t o, Ix. e, Ij x x 1Aiy I , X, X x X 4 j L if x q X x X Xw t c t X tItems with an asterisk denote conduction through an interior surface to another room shown I � . " ' ?Tt '12,7541,. Page Total: 0 "'14Ftration:­1 � x 1 M4 1.00 -0 `10.60 X io� V-5:rl, •_441 :0 ET -- -L._64] -:5c Sensible hedule Air `ceiling Height ACH, jr -Fraction 11-1;ROOM HEATING PEAK,.LOADS -?'TOTAL: HOURLY HEAT LOSSTPR ROOM 4, 1"!C": 12,754 L T'. Ene rgyPro'3.1 By EnergySoft 41 7 User Number:.5533 Job Nurribev, ojec�tTitle,j, "Pierce,C -J!Date�, d" rp&'ti6n a 19 /7/05., 0,0 .4 t [Woom Information! Design Conditions"' j_ Room Name r 'Owner's Suite Time of, Pe • 12 am Floor Area*%1,0761 Outdoor, Dry Bulb',Temperature, At, 4 260E Indo D Bulb'Terrip�irature 4 OF 4,- % or ry 7 0 4 0 , • as _��O�duction'i',,, 'Are a r' a U -Valu 0 F Btu/hr R-38 Roof (R.38.2x14.16)' R-21.Wall (W.21'S6A6)' Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Slab-0;-Gracle­r'..-­'• 0 27: P4, 7 L % + -0.0280 1,326 �11 "06.0 X C X, I 1,072.0 X 0.0592 X -44.0 2,793 93.0 0.6000 X 44.0 2,455 115.0 0.6400 4,.X 1 -44.0 356 t to ' 20.0 ,,'X' :i0.5500 'X -i Jf 44.0 484 - I - periniet6r 120.0 x 444.5 .5,340 X x Q_ - x X- X'. x x 4 x x - x X x X, 7, x 4 X xi x I x x x X x + X, x A X X.} x x X X, _x x 4 x x x X LW Lit v ,X 'x- x t o, Ix. e, Ij x x 1Aiy I , X, X x X 4 j L if x q X x X Xw t c t X tItems with an asterisk denote conduction through an interior surface to another room shown I � . " ' ?Tt '12,7541,. Page Total: 47 I i, "'14Ftration:­1 � x 1 M4 1.00 -0 `10.60 X io� V-5:rl, •_441 :0 ET -- -L._64] -:5c Sensible hedule Air `ceiling Height ACH, N 6T. __ 06 -Fraction -?'TOTAL: HOURLY HEAT LOSSTPR ROOM 4, 1"!C": 12,754 L T'. Ene rgyPro'3.1 By EnergySoft 41 7 User Number:.5533 Job Nurribev, Fag e: 2 8 of 41,4; v, V .4 t ROOM.HEATING PEAK LOADS 4 J g,. .Andrew Pierce Corporation Date <, 9/7/05 ' Room Information Design Conditions ' Room Name Great/Dining/Kitchen/Office Time of Peak y Area,.3,030 Jan 12 am (Floor Outdoor Dry Bulb Temperature 2t3OF, Indoor Dry Bulb Temperature ' 700E . OT, PF Btu/hrti , Conduction — Area " .U -Value R-38 Roof (R.38.2x14.16) • —_T f ,.3,030.0 � X ._ 0.0280 x' - 44.0 �- – 3,734 - R-21 Wall (W.21.2x6.16) _ 2,048.0 x w 0.0592 X 44,0 = _ 5,335 ` , .,[Solid Wood Door 64.0 X 0.3872 X- • 44,0 = 1,090 Double NonMtl Tinted - 172.0 X 0.6000 X 44.0 ` = 4,541 " ' Double NonMtl Tinted 324.0 { X 0.5500 x 44,0 = 7,841 Double NonMtl Tinted 64.0 X 0.5400 h x 44,0 Slab -On -Grade perimeter= 365.0 t X Ao x 44.5 'X X _ – , -x x. x x 4 x x _ r,.. ''' .. X x H x Xr - _---_� x x = x x �Y — x x c 1 x X = X X _ - ' t X X r = x. x _ x M X • x x = x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. Page ,Total: ao,3oa Infiltration: [ s 1.00 X 1.064 X 3,030 x 11.40 X =.O.. / 60 x' I = j . 0 Schedule Air Sensible ' Area ` Fraction . Ceiling Height. ACH . -J _ oT a s o - TOTAL HOURLY HEAT LOSS FOR ROOM 40,364 EnergyPro 3.1 By EnergySoft , User Number: 5533.1 Job Number: Page: 29 of 41 FOOM, HEATING_ -PEA K LOAD S•' x.; Project Title ' Andrew Pierce Corporation 'r- �r ' } :� �� r "• " jDate 4 9/7/05`' 3, Room Information Design Conditions; Room Name Second Flr Guest Suite ,Time of Peak r ' Jan 12 am Floor Area 9o9 Outdoor Dry Bulb Temperature �. �• .* 26°F Indoor Dry Bulb Temperature 700 Conduction ' Area" 'U -Value '•' `' . OT °F` • " .Btu/hr ` Roof (R.38.2x14.16)909.0 R-21 Wall " '�X 0.0280: * 'x 44.0 ., 1,120 +-38 (W.21.2x6.16) 1,420.0 X 0.0592 X 44.0 3,699 ' - • -Double NonMtl Tinted- 97.5 X 0.6000 X ;44.0 = 2,574 Double NonMtl Tinted 108.0 ' X., 0.5500 ..,.0.6000 '. X 44,0 2,614 ,-., Double NonMtl Tinted Default • i 12.5 x , , ` X 44.0 — 330 ' X xX - X. J c 1 a x ----------------- •! I_ f X, X .. . X. .i ! X — n T X. ,. xt' X .. x z • ti X X t: _ s X x' — s X X 4 X x ,x x r r X X = s ' + X'_ X e = x' x " Items shown with an asterisk (') denote conductioh though an interior surface to another room: ' , Page Total: FT 10,337 -Infiltration: I x '•1.064 x "`909 x° �= 9.00 x 0.00 _/ 60� x _ _1.00 Scheduler Air Sensible Area Ceiling Height" ACIH— TOTAL HOURLY HEAT LOSS FOR ROOM " r ' t.• 10,337 , z 4 �• +. EnergyPro 3.1 By EnergySoft .. User Number: 5533 ' Job Number: Page: 30 of 41 —1 ROOM- HEATING PEAK LOADS. ` roject Title 1, Date :'Andrew Pierce Corpora tion .. ' = ' 9/7/05 Room,lnformation' Design Conditions - Room Name Guest Bedroom Time of Peak . Jan 12 am Floor Area` 401 Outdoor Dry Bulb Temperature 26OFx Indoor Dry Bulb"Temperature 70°I �. . Conduction - Area t: U-Value�T OF' Btu/hr s R-38 Roof (R.38.2x14.16) 163.0 X " 0.0280 x 44.0 = 201 R-21 Wall (W.21.2x6.16) 618.0 X-, ` 0.0592 x 44,0 = 1,610 Double NonMtl Tinted 12.0 ' X 0.6000 x 44.0 = 317 Double NonMtl Tinted 40.0 X 0.5400 - X q4,0 = 850 r Double NonMtl Tinted ` • 40.0 '`• x 0.5500 X, , 44.0 •_ 968 ' Slab -On -Grade ' perimeter=67.0 x x ' 44.5 , 2,982 x x _ x x _ • x x X. x _ _Xry X = r x X X s X = f— X, x x x = x x x x x= i �. . x X = .. t. x x — Al -- x . x = X. + x x X, X x — ..- . x x _ x x = x ' X = s' Items shown with an asterisk ( ) denote conduction through an interior surface to another room. ,• x;• •Infiltration: 1.00 x 1.064 x 401 x 10.00 x 0.00 / 60] x' Page Total: _ 7,028 ' k -0 Schedule AiF Sensible • Area Ceiling Height ACA �T Fraction t TOTAL HOURLY HEAT LOSS FOR ROOM j ! 7,0281 EnergyPro 3.1 By EnergySoft User Number: 5533 ' Job Number: Page:3`1 of 41 Room Information :•:T f tlr. i •,�T ' Design Conditions Room Name'•►�' , Casita f?..r, ,r r y i:4 f .�3 - Sr • � r ...�,, - � y } t v f' .t "'4"�'� r x 3, •,� �"•` '. � y, f .y ° r F�.7 y. r ��'.y- , € ;'� y •+pKt � , r( i:,� h j � r .3s•'rx =.� it ' " v' 114.5 0.6000 fr` 44.0, 3,023 " t X`0 '.!"I-',HEATING ,FR OMN- PEAK -LOADS F i {, , r - X4: `F­ rrtr ' 150 - - rs_ - r. v �' • !� X 0 i i Irft .r # i,*k• �'qJ" S� �R'..dSnf . y . o • � . 744. 0 _ 581 , X .. x �t ', , ro ect Title • , �, ,44:5 ♦ �` <f""• Andrew:Pier6e Corporation �'' _ . k�* �►f4,' `�° ' 9/7/05 5.. y %( Room Information :•:T f tlr. i •,�T ' Design Conditions Room Name'•►�' , Casita Time of Peak', . > Jan 12 am , ` »" f ' ' ° N.4:, 737 ..yy, Outdoor Dry Bulb Temperature u26°F, Indoor Dry Bulb,Temperature .! �o of,r a • `=4 : ` �� 1 r '�" • i r, - ,Er 'y♦ M1 X' X ' " fir, - ry, • a S F onduction' ,z q �t s �,.;U-Valu ,•,.ToF ti 'Area ' v t a t 0 Btu/hr R-38 Roof (R.38.2x14.16)' R-21,Wall (W.21.2x6.16)' < ; . •i Double NonMtl Tinted Double NonMtl Tinted' Double NonMtl Tinted Slab -On -Grade I:' Y t.4 R a rr ♦ t - .Items shown with an asterisk (') denote conduction through an interior surface to another room `• :, _ 737.0 . rx ` 0.0280 x ' t- 44.0 ♦ _ `908 , ` F - r 1 00 X ` .1.064 x ' , ` . ; 737 x w ,i10 00 x ", 0.00 / 50i •OM1 - y m: x 44 # ";'j, } Jpyt. ' ' ♦ /r is , .•�., Schedule Air Sensible Area. i a Ceiling Height �+ .ACH, s +. `a. Fraction -;E" ., f,y ..741.5 r ; 0.0592 . 44,0 ".1,932 r, - ,Er 'y♦ M1 X' X ' " v' 114.5 0.6000 fr` 44.0, 3,023 " t X`0 ' 1X- ° .. w _ � s, 1` f :.a `� w '�' ` �t:'. i,.. � _ + w r _ f s„ �`;�s .� F i {, , r - X4: y X`e rrtr ' 150 ' 0.5400 44.0 _ y •356 v X0.5500 • !� X 0 t 't wr. p• 24.0 744. 0 _ 581 , X .. x �t ', , perimeter =118.0 ,44:5 _ 5,251 ? " i X 5.. y %( 1� y„ `"r w1 f♦ r .' f • ae X,',; ` �X'iX XI" x f� "� 'xtf ,;., . . ^ . to t• Y.. t ,-.. � a � F,. ' - .,. y. r •fir +'i x :,•. ` �' %x �' •(:' 'l= 't �♦} .. �.!� �. ,'•;` ix it, •�r' G• -' �.�, ' �..r r�. T-. X MX�.,i. ',; t I ' �... �y�� ? r T:,",ti�lr.'I¢e•+ N x'`~•�••Xi ?2 }�. r, x' rr " J' 'fi`, .. �y Y X • X',,e ♦ 7 X'' 1,• T x •X, • rX i ,x 3•�1,w •y1 _ } - , f' n. - - �wt+f -a 'X;:Fi X X " Y , oft. nX .. p ♦ _ Y M'' 4 �,'. ! L Le ±• .Items shown with an asterisk (') denote conduction through an interior surface to another room `• :, ' • w ` "`'' �" a N + , , t ;' • f Page Total:-, 12,051 _ n• r f �;t Y•." Infiltration: I F - r 1 00 X ` .1.064 x ' , ` . ; 737 x w ,i10 00 x ", 0.00 / 50i •OM1 - y m: x 44 # ";'j, } Jpyt. ' ' ♦ /r is , .•�., Schedule Air Sensible Area. i a Ceiling Height �+ .ACH, s +. `a. Fraction -;E" ., f,y ` •�T. I c "f. ,` , .,jai' 3 �''t Wit: O ��''v�f ';. •'�1.' ,f,-sf •. .•• �. M1 _ f - !-, `,_ -..x ;J s. ;' +.. r, - ,Er 'y♦ M1 �. TOTtS AL HOURLY HEAT<LOSS FOR ROOM, r .q�• w - f ` . r .. f� .. �, '�'; M1 ��a• " ,� - - ^ •r e.. ry _. - rfy . •S 7 - r ..i r,Fr � ._ -. .. w _ � s, 1` f :.a `� w '�' ` �t:'. i,.. � _ + w r _ f s„ �`;�s .� F i {, , r - s �EnergyPro 3.1 By Ene*Soft,, User Number: 5533 'Job Number: s =� r Z Page 32 of 41, * r t•n r � ''v .i a } r,.�s 't s w !I L. .'✓ K- f � r i'�� ii ♦� tl �°. v ` +'� rS,t ZL, ` 4 ` +' K. `t`{'{} ". `. f. 6 T;. 1 tk tG tr• .. # G ? {. ti. d } v Yr r , x L ., t 't wr. p• RESIDENTIAL ROOM COOLING LOAD SUMMARY Andrew Pierce Corporation 9/7/05 • Protect Title Date Room Name Owner's Suite Design Indoor Dry Bulb Temperature: 74°F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 38OF • Conduction Area U -Value. DETDBtu/hr X (North) 55.0 = 1,657 X Window Window 34.6 = 2,196 X (South) 38.0 = 2,120 x 38.0 = 308 X 38.0 = 418 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 6,700 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window _ (North) Window (East) Window (East) Window Window (East) (East) Window (South) Window (South) Window Window (South) (South) Window (South) ( 0.0 x 15+ 6.0 X 15)X 0.512= 46 ( 0.0x 151+ 15.0X 73)x 0.512= 561 ( 0.0x 15+ 15.0X 73)x 0.512= 561 ( 0.0 x 15 + 15.0 X 73) x 0.512 = 561 ( 0.0 X 16+ 15.0 X 73) X 0.512 = 561 ( 0.0 x 15 + 20.0 X -62)X 0.512 = 635 ( 0.0 x 15'+ 6.0 X 62)x 0.512= 190 ( 0.0 x 15+ 6.0 X 62)x 0.512= 190 ( 0.0 x 15 + 15.0 x -32)X 0.512 = 246 ( 0.0 x 15 + 15.0 X 32) x 0.512 = 246 Sched. Page Total 3,7x7 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,076 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 1,076 X 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 1,076 x 0.000 Watts/sqft x 3.413 Btuh/Watt - 0 Process 1.00 x 1,076 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration:[ 1_00 x Air _ 1.064 x 1,076 X g 10.60 x 0.00 / 60� 38 = Schedule Sensible Area Ceilin Hei h ACfi QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,496 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,076 x 225 Btuh/occ. I 0 sgft/occ. = 1100 Receptacle 1.00 x 1076 x 0.000 Watts/sqft x 3.413 Btuh[WattProcess 1.00 x 1076 x 0.000 Watts/sgft x 3.413Btuh/Watt Infiltration: L 1_00 x 4,771 x 1,076, x _10.60 x 0.00 / 60] 0.00000 = �- 0 Schedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 33 of 41 RESIDENTIAL ROOM CO,OLL,NG LOAD, SUMMARY • Andrew Pierce Corporation 9/7/05 Project Title Date Room Name GreaMining/Kitchen/Office • • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 38°F Conduction Area U -Value DETD' Btu/hr X (West) 55.0 = 4,667 X Window 34.6 = 4,196 X (West) 34.6 = 857 X Window 38.0 = 3,922 X 0.512 38.0 = 6,772 X 62) 38.0 = 1,313 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 21,726 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGP SC Btu/hr Window (West) Window (West) Window T (West) Window (West) Window (West) Window (West) Window Window (West) (West) Window (North) Window (North) ( 0.0 x X X X X x x x . X 15 + + + + + + 15.0 X x X x X X X x x 62) x x x X x 0.512 = = = = = = = = = 476 ( 0.0 15 15.0 62) 0.512 476 ( 0.0 151+ 12.5 62) 0.512 397 ( 24.0 15 0.0 62) 0.512 184 ( 12.5 15 0.0 62)x 0.512 96 ( 0.0 151+ 20.0 -73)X 0.512 748 0.0 1 40.0 73)x 0.512 1,495 ( 0.0 15 20.0 73)X 0.512 748 ( 0.0x 15+ 15.0x 15)X 0.512_ 115 ( 0.0 15,+ 40.0 15) 0.512 307 Sched. Page Total 5,oa3 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 3,030 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 3,030 x 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 3,030 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Process 1.00 x 3,030 x 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Infiltration: [ 1_00 X _ 1.064 X 3,030 x _ 11.40 x 0.00 / 60] 38 = �p Schedule Air Sensible Area Ceiling HeigFt ACH QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,081 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 3,030 x 225 Btuh/ocC. I 0 sgft/occ. = 0 Receptacle 1.00 x 3,030 x 0.000 Watts/sgft x 3.413 BtuhMatt = 0 Process 1.00 x 3,030 x 0.000 Watts/sgft x 3.413 BtuhMatt = 0 Infiltration: [ 1A0 x 1 4,771 x3,030 x _11.40 x 0.00 / 60] 0.00000 = Schedule Air Latent Area Ceiling Height AUK /mow Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 34 of 41 i- 'e • * f Jar,- , •. r ? _• t •�' t F' 7r _ ' • .. .14. � .Y,. Ftp, � . - s1. h - I " �• 2 J %7. ,(East)_ ?: .6.0 { RESIDENTIAL'ROOMCOOLING •LOAUSUMMARY h'..r'. 3 0., 15) 0.512 4,77 0.0 t . _15)X 0.512 Andrew Pierce' Corporation x ' ` `: " 9/5 7/0 ('•0.512 "96 Protect Title 12.5 48) Date , 307 0.0 •, f t, 0.512 + 0.0 . Room Name•�`r'Great/Dining/Kitcheln/Office 73) 0.512 0.91X ' 24.0 'Design Indoor Dry Bulb Temperature:r . 0.512 ' �A ;� � '�~ t "' T 74°F: ;s • : �'` " ,��; , • »` . ' Design.Outdoor Dry Bulb Temperature t., ' ' `112°F r' • Design Temperature'Difference: * ' Ali . �f.' •'3$0 ,M. `Conduction: ': '(' .:. a _ Area R•'f.► U -Value •nFTfIa : r R4rdhr • i ti` �1 Window (North) Window! r 1 `" _ (North)"• Window' 'k a (North) Window; Window' t. Window -l: Window' i E, , ^ (East) Window'• 3`I` i } •." ,(East), Windows ,(East)_ ?: .6.0 '• 't 15)X X' F , •_ 1 Merry t X _ .X X X 1 Design Equivalent Temperatre Difference (DETD)'° • ui Page ,Total,,+ �. _Items shown wdh'an asterisk (') denote conduction through an interior surface to another room: , , ;.+ r _ Shaded ` ' UriShaded Solar Gain ` ' ` 'Orientation ' " ' , ' Area 4 'SC Btu/hr ' Area , SGF SGF , F Window (North) Window (North) Window! r 1 `" _ (North)"• Window' 'k a (North) Window; Window' t. Window (North) (North) (East), Window' i E, , ^ (East) Window'• 3`I` i } •." ,(East), Windows ,(East)_ ?: '...1).0X'`. 1..°0.0 X x X X X X7. X X 15+ =15 +` ..• .`.15 + ,15 +' 15 + c '_ 15 + 15 + x,15' + 15 + _x,15' +' 6.0,x` x X X x X x x X 15)X X X x X )'x !0.512= — — = = 46 J r, y z s - . 6.0X. 15)X .0.512 4` x;46 0.0 .6.0 '• 't 15)X 0.512 W46 .0.0 10.0 15) 0.512 4,77 0.0 - 12:5 _15)X 0.512 ""; 96 r0.0 12.5 15)x ('•0.512 "96 0.0 12.5 48) ' 0.512 307 0.0 •, 20.0 ,*y 73) 0.512 748 0.0 12.0 73) 0.512 0.91X ' 24.0 73 . 0.512 897 ,•` , �Sched. �. �, # Page Total + Internal Gain Frac. Area'iHeatGairi' Btu/hr' Lights Occupants ' 3 Receptacle , Process ` 1.00 .X 3,030 x 10.000 Watts/sgft x =3.413 Btu' h 'att' — .0 1.00 x 3,030 x "'- 255 Btuh/OCC. `/ '0 Sgft/OCC I 1.00 x 3,030X 0.000 Watts/sgft x 3.413 Btuh/Watt It0 .. 1.00 x 3,030 x 0.000 Watts/sgft X. 3.413 ,Btuh/Watt 'Infiltration: Cr 1.00 " x 1.064 x 3;030 x 1_1 40 JxY _ 0 00 / 6Q - 38 Y ` Schedule Air Sensiti a Area Ce,hn�ieight ACH; - ± +' Fraction' V r K ° TOTAL HOURLY SENSIBLE HEAT. GAIN,FOR ROOM' t. t, 33,081 t iAVr S ? r Latent Gain r 'Frac. - Area ;'' Heat Gain ` -, , t. aBtulhr f ` Occupants x . 1.00 x . 4 3,030 x� 225 Btuh/oCc / o sgft/occ. _ J�o t u ` Receptacle, • 1.00'X 3,030 x .;4' 0.000 ,Watts/sgft' x r 3.413 Btuh/Watt` = Process ' 1.00 X 3,030 X 4,t f ��' 0.000 Watts/sgft x 3.41Btuh/Watt ' _ ,`s Infiltration:[ 1 00 x 4,771 x 3,030 'X _11 40 x,, � / 6Q� .�� 0.00. 0.00000 n * 0 r ,. ,Schedule A,r Latent t �' Area Ceiling Heigti ACH, yy •"i Fraction H•." "t . w , w t. , r ',+. TOTAL HOURLY LATENT HEAT,GAIN FOR ROOM ` .' .`;. „ . +0 a EnergyPro'.3.1 '� By EnergySoft ' q'! , User. Number. 5533- . a Job Number < ^ ' 1 s r ~ ' rF. Pager 35 of 41 }i Y V. • l ;�:- i ! , i . - .. .. • t � n , .. �• .- } r � r ! i `- 4 i A � • 4 • • e ! �; • t w. ji tt '.. ,. -'. _'*t i ,, ' .. --3 _ tP•' •{4.. � (South) �� .r •Yr i ! fr j'� �..'" 4a` •. s' i �. RESIDENTIAL ROOM'`COOLING'LOAD-SUMMARY • Y 37.8 ,.N Pierce Corporation-.-•: r 2,505 _ �`• -9/7/05 T a •.Andrew Project Title r r' Date .a , k. ' Room"Name �. •_.'397 Great/Dining/Kitchen/Office } 32)x' '0.512= �.� j ' '' Design'Iridoor Dry Bulb Temperature. F "� {=74oF; z' Design Outdoor Dry,Bulb Temperature: ~ ;*:. r'� ;' ' 112°F ` w Design Temperature Difference:, y - ; t , 380F, Conduction °' Area ; _ U -Value DETD.1 'f . t�tr,/hr X X X f` y X ' X • .� = f X Ll 1. Design• Equivalent Temperature Difference (DETD) £ ,.Page Total = o Items shown`with an asterisk (`) denote condu6tion through an.interior surface to another room. t Shaded Unshaded . , . • y „ Solar,Gain Orientation Area': SGF Ar { , MA ea •SGF SC, Btu/hr at 4r Window4'. (East) Window _ (East) Window. (South): - Window ! , +" (South) = ~449 ( 142.2 37.8 73) 0.512 r 2,505 ( 0.0 •12.5•x'.. 62)x'.0.512= ( 0.0 x X X ! '15+ 15' +' 15+ 15+ X12.0 x x 73)X''.0.512= X : = ~449 ( 142.2 37.8 73) 0.512 r 2,505 ( 0.0 •12.5•x'.. 62)x'.0.512= •_.'397 ( ' 20.0X< 0.0X 32)x' '0.512= 154XL • A 1 J' t !' -•, '�. �+ Y r ..t,,_ a .. . f �„ .! • j ' Schell. aY Page Total 3,5oa Y,i' Internal Gain' Frac Area Heat•Gain, ' r y '� �w - t;' Btulhr, r T •t Lights ;a " '' ' ; , „ 1.00 x r .3,030 X '0.000 Watts/sgft x " 3.413Btuh/Watt 4 ` • 0 Occupants • ' ,' 1.00 x 3,030 x , 255.Btuh/occ... / _o sgft/occ. _ oI f• Receptacle 1.00 x 3,030 X' , %0.000'Watts/sgft x 13.413 $tuh/VVatt `._ 0 r Process` w 1.00 x '3,030 x 0.000 Watts/sgft X 3.413' Btuh[Watt', 0 ° " Infiltration L 1_00 a x 1.064 30 ,x 3,0 x" 11.40 x Y 000 /,6� '38 '= 0 Schedule r Ai Sens}bie l Area Ce}hng Height ;' ACH Fraction TOTAL'HOURLY SENSIBLE HEAT GAIN•FOR ROOM 33,081 ,' o k f 3 ached Latent Gain +'• Frac. Area Heat Gain',_. Btu hr, sk? , Occupants , r 1.00 x 3,030 x 225 Btuhlocc." I 0 sgftlocc.: r — ,`• i 0 + r ... Y ; Receptacle 1.00 x 3,030 x 0.000 Watts/sqft x 3.'413 Btuh/VNatt = +0 = Process' 1.00 X 3,030 X 0.000,Watts/sgft x 3.413:Btuh/Watt.' = r0 " • • i i Infiltration ['• 1.00 k' 4,771 x y 3,030 X ' 11.401.x 0.00 :/'60] • 0.00000 = ' „ I �,'; _ Schedu a Air Latent Area. Ce}Img He}gfi + ACH yy - Fraction - - 7 _x, • • - "i. *� -• _ rr - A • - ;? . TOTAL HOURLY LATENT HEAT GAIN'FOR ROOM, . _ _• .,,,;° r 0 EnergyPro 3.1. _By Energ,ySoft , User Number 5533 �- !,'Job Number:. , f x , , Page 36'of 41_ R-38 Roof (R.38.2x14.16)., R-21 Wall (W.21.2x6.16), Double NonMtl Tinted' Double NonMtl Tinted, Double NonMtl Tinted Default + - 909.0 -1,420.0 97.5 5 108.0 -' °� •" 12.5 1 x 0.0280 0.0592 0.6000 0.5500 0.6000 X • 55.0 = 1,400 r 34.6 2,909 X% = .(West) (North) '- ? 38.0 2,223 X ' = Window "_ , i 38.0 2,257. X ' = ` ..+• = . 12.5 ' +RESI_DENTIAL,ROOM'COOLING}LOAR-SUMMARY X ( 0.0 24.0 62)x' • Andrew'Pcerce Corporation ,' w `9%7/05' P' 40.0,x r Protect Title Date ' r ,1,270 f (Room Name •.' !� Second Flr Guest Suite' ' ,�• ,.•. Design Indoor Dry~Bulb Temperature: " ' : • t '' 74°F "# Design'Outdoor Dry Bulb Temperature: ' F"�, +. \ -' 112°F 6.0X ` Design, Temperature Difference: • #' r " •' `380F ( 0.0 12.5 .0 b 96 s•Conduction Area -Value DETD' Btu/hr � R-38 Roof (R.38.2x14.16)., R-21 Wall (W.21.2x6.16), Double NonMtl Tinted' Double NonMtl Tinted, Double NonMtl Tinted Default + - 909.0 -1,420.0 97.5 5 108.0 -' °� •" 12.5 1 x 0.0280 0.0592 0.6000 0.5500 0.6000 X • 55.0 = 1,400 r 34.6 2,909 X% = .(West) (North) '- ? 38.0 2,223 X ' = Window "_ , i 38.0 2,257. X ' = ` X = . 12.5 4,; 38.0 t 285 X ( 0.0 24.0 62)x' 0.512 762 ( 0.0 40.0,x 62)x 0.512 ,1,270 1. Design Equivalent Temperature Difference (DETD) r .- . r + V Page Total' ! • "sh•� , , i i kr '• , 9,oi4 r Items own with an asterisk (•) denote conduction through an interior surface to another roam. , r x -Shaded- Unshaded Solar Gain "� Orientation Area f SGF Area ,R, SGF ',,SC Btu/hr r - t • i i Y Fed Window. z ,� -�. _ ••+ (West) Window . , w • � ( West ' ) Window r (West)., Window " r • s _ Window s ' (West) '(West)1' Window + _ Window +-... ~' r .(West) (North) Window �.: (North) Window,, { ` r+ (North) ` Window "_ , i (North) ' .6.0 X X X X X X X' X-,,15)'15+ x X' 15;+ 15 +t 15 + 15,+ 'id + , t' 15,+ `i, 15+ 15 + 15 + 0.0 X x x X x X X x 62)X x x :+0.512 = = = = = = __ c 46 .rr ,•'.' , �t "• ( 6.0 0.0 62)x. 0.512 _ 46 (- 0.0 12.5 62) 0.512 +' .397 ( 0.0 . 12.5 • 62)k •.0.512 397 ( 0.0 24.0 62)x' 0.512 762 ( 0.0 40.0,x 62)x 0.512 ,1,270 ( , .0.0 10.0 15)X 0.512= 77- 0.0 •10.0 0.512 77 ( 0.0 6.0X 15)x '-+ - 15)i 0.512 •a "� '•46- ( 0.0 12.5 , 0.512 b 96 i ' t - +Y )» ; • ., -� •' - F SSE , Y, . '- J y ^ # *Sched: ' ;fir• Y . Page•Total 1 3,214 < y • r, • . ,. Internal Gain "+Frac. • Area ' HeatGain'r t Btti/hr Lights , 1,1.00X 909 x 0.000 Watts/sqft X 3.413 BtuhlWatt , t= Occupants 11.00 z 909 x 0 'Btuh/occ'. / ' 20,000 sgft/occ. = 0 io �_ t Receptacle ''1.00 z 909 x 0.000 Watts/sgft x ° 3.413 Btuh/Watt Process `i `1.00 x 909 x 0.000 Watts/sgft x 3.413'Btuh[Watt +• 0 "�- Y Infiltration 1 00-'1 "x'.064 x , 909 X . -.9-01 x t - 7 0.00,/..60]' Q. 38 0 1+e�i ule • Air Sens! a Area Ceding Height ,. AC �� ; . •. . `i Fraction TOTAL•HOURLY SENSIBLE HEAT -GAIN FOR ROOM' • =% t fi + 13,333 Latent Gain Frac. Area Heat Gain Btu/h'r ` r ' Occupants` u'E,�,-i000 x 909 x r - �' o Btuh/rice. / , r 20,000 sgft/occ. 1 p Receptacle x 909 x 0.000 Watts/sgft x 3.413 Btuh/VVatt.' = 0 Process .:•. �_ x _ 909 x 0.000 Wattslsgft"•x 3.413 BtuhIVllatt '- '. 0 Infiltration [ 1.00 X =4,771 X r :. . 909 'z _ ,9.00 xx °l].00 /.60� Schedule 1 Air Latent Area Ceiling Height XCH /\yy y Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM tr', o j, Ay. •• ' " ` EnergyPro 3.1 _ By EnergySoft ' `j User Number: 5533'e- ! !' • y • ;'Jo'b Number ' ! Page: 37 of 41 t. -Ty r•f.• t ~. f _ .: 4 ��Y ; • t; 7.. -;�YA� .+r. _ L S'•? } '�',� • Y. X ... (North). V � •x X X X x" x -,62)x iX �.y� / :. + i♦ .r *w r i. . n . f , ,l� r ~ •, � , �'!i � .. 4 i .� ±9 ��} •ri-M ., .'� 1r1• yrq r f i : -.'Y � � • • � 't l � p MT•7 f'� � ' � 1. M 4 � 1 { Y} ?A� � �; cR r T-• • i1. •e .,} ♦ s � � 1 1•. ,. �• • P � � y �,. ' : w '1 i " ki k . '. t�. i � A 1' - � f . 1: ` � ,p' ♦ � *." ^Y� � / r j,'.W ( f0-0 F Y RESIDENTIAL ROOM COOLING' LOAD�,SUMMARY •.� ^ 1473 4.2 62)x 0.512 _X = �' y ,0:512 r `0.512 Andrew Pierce Corporation `; s ( 1.0.0 '++ : ♦ ''"' • ;,' 9/7/05 •- ti . Project Title . • , + '`i , Date t. `Rooni Name '• ' w ' E 3. V. Second Flr Guest Suite # _ ; », Design Indoor Dry Bulb Temperature:', ` • - '' r; f k �. '74oF •' ,.Design'Outdoor Dry Bulb Temperature: • _` s ' ,' '. ;, •. '- 112°F ? ♦ t Desigri'Temperature Difference.. - k, y 380F-' •. rr w .. .. • .$ • .- . Conduction yi < '� _ , ' -Area` -; + _ U=Value DETD 1a 6tulhr° X * (North). V Window r,.� �, -f •x X X X x" x -,62)x iX (East) Window 0.590 '(East) Window: w W. ,° 'o N r*r 1N s r~J ` 3- of `. h , (South)' �.. ` I '. r`r .. ♦ y ( f0-0 X.. 48)X '0.512 1473 4.2 62)x 0.512 _X = �' X., ,0:512 r `0.512 „•' •`• 307 ( 1.0.0 0.0 ' ,v77'� r., a *r 1:' Design Equi ale'nt Temperature Differerice (DETD) �' .. , . . • .0 ,, �' Page Total a Items shown with an asterisk O denote conduction through an interior surface to another room. r z 4y ' ShadedUnshaded, • ►� Solar Gainer Orientation SSC ' .k Biu/hr ♦ t,. Area+SGF Area SGF " �- Window. ""` * (North). V Window r,.� �, -f •x X X X x" x -,62)x iX (East) Window 0.590 '(East) Window: w W. ,° 'o N r*r 1N s r~J ` 3- of `. h , (South)' Windows , ti, j 48)X (South). Window e ( f0-0 (South) ` 48)X '0.512 1473 4.2 62)x 0.512 256 ( 18.9'x 5.1 X., ,0:512 r `0.512 „•' •`• 307 ( 10.0 X X 'X 'X . 15 +• ," -15 + 15+ 15 + .: 15'+ 15 + 12.5 •x X X X x" x -,62)x iX t15)x )x 0.590 — — — = ; ` 141 W. ,° 'o N r*r 1N s r~J ` 3- of `. h , ( •_, ( 0.0 r 6.0 ti, j 48)X 0.512 r' 7 '147 ( f0-0 '-.6.0 48)X '0.512 1473 4.2 62)x 0.512 256 ( 18.9'x 5.1 62)x ,0:512 r `0.512 „•' •`• 307 ( 1.0.0 0.0 ' ,v77'� - .".��f ; ti 'r '� Yom. r.'. +r �4 x -t • • c r ,, ;1 ;Sch'ed. ' *' ,Area' .t, t Page Total 1,oa5 _ Internal Gain ` -Frac.` Heat Gain �` ;ti Btu/hr ,' ^. Lights ' s ; 1.00 x ` 909 x .0.000 Watts/sgft,x' •3.413 BtuhlVllatt = 0 4 ~ t�� Occupants r 1.00 x t "909 x ,• O'Btu h/occ •/ 20,000 sgft/occ. 0 s , Receptacle 1.00 x {- 909 X 0.000 Watts/sqft x •,3.413 Btuh/Watt _ r 0 f 'z'' Watts/sgft BtuhfWatt` = ro ' 41. Process 1.00 x 909 X 0.000 X 3.413. Irifiltration:..[ 1.00 x i ___1;064 x 909 x_. 9.00 x 0.00 / 60] r. 38 } = u« . 0 - �-»'+• ► Schedule. AirSensitile Y Area. , Ceiling Height ACH 4• , pT ,,�„ - g e• * '�� z -'` ` •` _ . Fraction - _ _ t -, `'. w !�;• , a.; ' ` q' +, : ¢. >- TOTAL,HOURLY SENSIBLE HEATGAIN`FOR ROOM *' t '.,. 13,333 r+ "`• .ter •�' .! ..r �•. $,-; * � I .4 � _ � 7# t` i q rtr r -',Schad. Latent Gain • " t Frac. Area Heat Gain f• Btulhrt `- �t i. r ..- y r . . Occupants t'. 1.00 x 909 x t-'* ''0 Btuh/ocC /: 20,000 Sgft/oCC _0 , Receptacle 1.00 x '' 909 x 0.000 Watts/sgft, x s. 3:413 Btuh/V11att' w 01 r� a r Process ,1.00 x 909 x r - 0.000 Watts/sqft x 3:413 BtuhlNVatt . . '!'0 ` -'Infiltration s ^' [ ' 1 00 x_4,771 V. ' . x . 909 :X ' 9 00 'X- 0.00 / 60� ,. o.00006 .Sch�ule Air Latent Area r Ceiling Heigh ACH1i 4 + y Ct :' . F a • `r i1 Fraction , • + " "r+ + s'. TOTAL• HOURLY LATENT HEAT GAIN FOR ROOM:_ ` o EnergyPro 3.1 ' By Ener gySoft �' ' ' User Number: 5533 h . Job Number: ' _ • , Page:38 .t RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation 9/7/05 Project Title Date • • Room Name Guest Bedroom Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 112°F Design Temperature Difference: 380F Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Area 163 12 40 40 X X X X X X X x X U -Value 0.0280 0.0592 0.6000 0.5400 0.5500 X x X X x x X x X x Window (East) . DETD' X 55.0 X _ 34.6 X 38.0 X 38.0 X 38.0 X X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window (North) ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( ( ( ( ( X x x X x x X x x x 15 + + + + + + + + + + 6.0 X x X X x x X x X x Window (East) 15 6.0 Window (East) 15 20.0 Window (East) 15 40.0 Window (East) 15 20.0 Page Total SC Btu/hr 251 1,266 274 821 836 3,448 Btu/hr 15)X X )X )X )X )X )X 0.512 = = = = = = = = = 46 48)x 0.512 147 48) 0.512 492 48)X 0.512 983 48)x 0.512 492 Sched. Page Total 2,160 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 401 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants _1.00 x 401 X 0 Btuh/occ. I 20,000 sqft/occ. = 0 Receptacle 1.00 X 401 X 0.000 Watts/sgft x 3.413 BtuhfWatt = 0 Process 1.00 x 401 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: � 1.00 x 1.064 x 401 X 10_00 . x 0.00 / 601 38 = Schedule Air Sensib a Area Ceiling Height ACK pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,607 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 401 x 0 Btuh/occ. / 20,000 sqft/occ. = 0 Receptacle _1.00 x 401 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 401 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration:[ _ 1_00 x 41771 x 401 x _10.00 x 0.00 / 60] 0.00000 = �� Schedule Air Latent Area Ceiling Height Ac /�,w Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 01, EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 39 of 41� A RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation 9/7/05 Project Title Date Room Name CaSita • • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 380F Conduction Area U -Value DETD 1 Btu/hr X (West) 55.0 = 1,135 X Window Window 34.6 = 1,519 X (East) 38.0 = 2,611 X ( 0.0 38.0 = 308 X ( 0.0 38.0 = 502 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 6,074 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btulhr Window (West) Window (West) Window (West) Window Window (North) (North) Window Window Window (North) (East) (East) Window (East) Window (South) ( 0.0 x x x x X x x X x X 175,+ 15 + 15 + 15+ 15+ 15+ 15 + 15 + 15 + 15 + 15.0 X x x x X x x X X x 62) X x X ) X X 0.512 = = = = = _ = 476 ( 0.0 15.0 62) 0.512 I 476 ( 0.0 15.0 62) 0.512 4761 ( 0.0 12.0 15)x 0.512= 92 ( 0.0 12.0 15)X 0.512= 92 ( 0.0 12.0 15)X 0.512= 92 ( 0.0 12.0 -48)X 0.512 295 ( 0:0 12.0 -.48 0.512 295 ( 0.0 24.0 48) 0.512 590 ( 0.0 12.5 -62)x 0.512 397 Sched. Page Total 1 3,282 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 737 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 737 X 255 Btuh/OCc. / 0 sgft/OCc. = 0 Receptacle 1.00 X 737 X 0.000 Watts/sgft x 3.413 BtuhfWatt = 0 Process 1.00 x 737 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: __1Ao x 1.064 X 737 X _ 10.00 X 0.00 / 60] 38 = �p Schedule Air Sensible Area Ceiling Height ACH \T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,737 Sched. Latent Gain Frac. Area Heat Gain, Btu/hr Occupants 1.00 X 737 x 225 Btuh/occ. / 0 sqft/occ. = 0 Receptacle _1.00 x 737 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 737 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1_00 x 4 x 737 x _10.00 x 0.00 / 60] 0.00000 = Schedule Air Latent Area Ceiling Height ACH �w Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 40 of 41 � � a, ♦ a. w ♦ . c, �. � - t - ,�� y K t : ;r - •� S, ,,,• i � i `5} a,.. � T y�r � r. w xi• tRESIDENTIAL. Rr_ OOM COOLING'LOAD SUMMARY r f'=•Andrew'Pterce'Corporatioln` '� c ►��"_ ,9/7/05 •7 Project Title - ` �{ :p ; Date r +j } :r 4' r (Room Name,`' �. r: �` .''' 1 "CaSlta,: " ~ ,.; + L to P ti r -. R. n,"s..... " - .? •`i ' T' 1. . t t , . ,yvw •* t 'i , r _ , • . 'Design Indoor Dry Bulb Temperatures:•. :e. ,F; ; ` ;`1 - , { s ..�'-%40FYT, Design Outdoor D Bulb T r 7 3 a ` ry u b emperature t { r F+ _h, " , r' '� , 112°F - ;•« r "•Deslgn'Te'mperature Difference:' ' ` _•` y ' s '380 t F a F' Conduction ,' ' + Area �' ,mss: "� U -Value �t''� DIET t ' n` Btulhr; r A4 • ar . � w ��f rP to X. r Y X ' y• rs z. r X XAi rr_ c 1 , r:• xi. E µDesign Equivalent. TemperaturerDifference' (DETD) °; s �� - f .. '4,+ t: ` r d _.� t _ r Items shown with an asterisk O denote conduction through an interior surface to another room.^` a Page Total:, 'o r: _�',f" . j' ,', Unshaded' � Y « Solar Gam f `' ' . = Orlentatlon ;Shaded' Area SGF .' , ",Area t' 4' :SGF , ;k. SCS `' ` �' Btu/hr .:' •[, + .t" :3"� •i .. 'fir X. r Y X ' y• rs z. r X XAi rr_ c 1 , r:• xi. E µDesign Equivalent. TemperaturerDifference' (DETD) °; s �� - f .. '4,+ t d _.� t _ r Items shown with an asterisk O denote conduction through an interior surface to another room.^` a Page Total:, 'o r: _�',f" . j' ,', Unshaded' � Y « Solar Gam f `' ' . = Orlentatlon ;Shaded' Area SGF .' , ",Area t' 4' :SGF , ;k. SCS `' ` �' Btu/hr .:' •[, Window X - X- (South) Window'. `i+ ` '1'•' * +' (South).. �.. `62) Xy 0.512 Area . .190 ( 16.0 15+` 6.0 f° 62)x x.0.512 •[, + .t" :3"� •i .. 'fir Process,: - - - e X "t _Watts/sgft x _3.413, Bttih/Watt '. .• �, '0 ( 0.0 X - X- r`• 15 +, 6.0 X X `62) Xy 0.512 Area . .190 ( 16.0 15+` 6.0 f° 62)x x.0.512 +` 0 Receptacle �' 1.00 Process,: - - - X - t 2,737 X ,, : o.000 _Watts/sgft x _3.413, Bttih/Watt '. .• �, '0 ." , X + X ) x P _ • .'', ( t i �r ih X 7+ L eX ° )X% w.J"' r1 • a ( F'" . ]' • t X '+ .. rx1x x / X 4 rM• • ; ;Q r; ( Y • 11i' �'7..-' y� • y_. "Yt•,3:? � ;f4 yy 44k+'°°y ,- 'T .r, 'rSched. .- 'f ` * .• �y,t' � � k - .+!� �. f Page Total ♦ h Internal Gam Frac. Area . r `` Heat Gatn`�'s Btu/hr ;• , Lights i";rt • Occupants', r a ` 1.00 X , . 737 X .737 X ' 0.000 y. -; 255 :•Btu h/OCC. r L { .BVr ' 0' Sgft/OCC ? • _ 0• , 0 xt 1.00 X x_737 x `O . 0.000 Watts/sgft x 3.413 Btuh[Watt — +` 0 Receptacle �' 1.00 Process,: - - -1.00 X - t 2,737 X ,, : o.000 _Watts/sgft x _3.413, Bttih/Watt '. .• �, '0 ." � 1. -f _ s .• - ti. i' •"r' f, [ � sr- s <�,t t t I�' e Infiltration ["s -1-00 1 00;,+X .1.064 'x 737 .x }.' 1000 x x'".000 /. 60] '38-i k �0I Schedule t� Air Sensib a Area. ♦ Ceiling Heigh ACH pT ��_ t + t 3 rr w Fraction TOTAL HOURLY SENSIBLE�HEAT GAIN-FOR'ROOM r. •;t , . w.1 J' , » �' �' t *.. 9,737 Sched • r k 'd' Y ' �.�5 s (� -'+ r a : -event Latent Gain ,w �, Frac..' Area Gain k' Btu/hr,:, [ Occupants 1.00 x "��737 X `` �`''' x225 Btuh/OCC. > l 0 Sgft/OCc ♦: Receptacle •; , '1.00 X 737 x . 0.000 Watts/sgft x 3.413 BtuhNVatt'°� c r; ' •j Process * " ±. 1:00 x <.737 x' �` t ..0:000.Watts/ScIft,zx' 3.413'Btuh/Watt = y'•.0 T `' ', " a Infiltration [ 1 00 x'. 4 771 x y 737 `•x ^10 00 x, ^ 0.00 / 60 ',0.00000 _10-.06 . w. ' ' 0 '";• +%t Schedules >Air Latent y Ceiling Heigh -' ACH- r� pW • . t '';t',' Fraction .;' ♦ - .* ?i. + a Ka rc + r k i } TOTAL HOURLY, LATENT- HEAT GAIN FOR ROOM_ __ ' ` •'�" ~s •: +.'0 r *' 1 - ..,, :.:. '11 f ..'+ ,i .t% i ,, '• r` „�, .ft r+ ■. aY'• ` f .t, t f '1. , �;. { ,,+ f EnergyPro 3.1 By EnergySoft User Number: r 5533 k . a1 Job Number.,' jx,' E i P ''Page:41 of 41N r^ - .r r ;Y- y ,ti�, r - '- .♦:.i• - +»3 `} 't. ; t .k � - vt 3 . ` t ,�),� i a2 •- a f � �„ f`iE * r' +.y a c' * •. .9"r. tis L 'st �:' �� . +.'. 3e� S' y • K -'q, ., F t '+s i r� a `�� . _'`• - f� -.W.d,- .Y... , t «.. - , 1 Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 October 3, 2003 ND La Quinta Partners, LLC 51-100 Avenue"53 La Quinta, California 92253 Attention: Mr. Dan Williams Project: The. Hideaway - Area D Via Pontito La Quinta, California Project No. 544-2199 03-10-638 Subject: Report of Observations and Testing During Fine Grading Ref: Geotechnical Investigation Report prepared by Earth Systems, Southwest dated April 11, 2001; File No. 08119=0T, Report:No. 04-04-716 Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002, File No. 07117 -IT, Report No. 01-07-718 Geotechnical Update prepared by Sladden Engineering dated May 13, 2003, Project No. 522-2199, Report No. 03-04-225. Summarized in this report are the results of in-place density tests performed at the subject site during the fine grading of the building pads along with pertinent observations. The subject lots are located along Via Pontito within the northern portion of the Hideaway project site in the City of La Quinta, "California. Fine grading was performed by Nuevo Engineering using conventional heavy equipment. The previously rough graded building pad areas were watered and the surface was recompacted with heavy equipment. Areas that extend beyond the previously rough graded pads were overexcavated to the revised building envelopes. Additional overexcavation was required on lots 2,3,9, 10, and 11. Soils obtained from other areas of the Hideaway project site were placed in thin lifts at near optimum moisture content and compacted to at least 90 Percent relative compaction. The fine grading was performed as recommended in the referenced Geotechnical Update report prepared by Sladden Engineering. Observations and field testing was performed from September 4, 2003 through September 9, 2003. Testing indicates that a minimum of 90 Percent relative compaction was attained in the areas tested. The passing test results indicate compliance with the project specifications at the tested locations and depths but are no guarantee or warranty of the contractors work. JUL 14 2005 va October 3, 2003 -2- Project No. 522-2199 03-10-638 Field Tests: In-place moisture/density tests were performed using a nuclear density gauge in accordance with test methods ASTM D-2922 and ASTM D 3017. A total of 19 density tests were performed. The approximate test locations are indicated on the attached plan and test results are summarized on the attached data sheets. Laboratory Tests: The moisture -density relationships for the tested materials were determined in the laboratory in accordance with test method ASTM D 1557-91.. Allowable Bearing Pressures: The structural values recommended in the Geotechnical - Engineering Report prepared by Sladden Engineering remain applicable for use in foundation design. .Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolatedpad footings should be designed utilizing allowable bearing pressures of 1800 psf and 2000 .psf, respectively. The recommended allowable bearing pressures may be increased by. one-third for wind and seismic loading. The bearing soils are non -expansive and fall within the "very low expansion category in accordance with Uniform Building Code (UBC) classification criteria. If there are any questions regarding this report or the testing summarized herein, please contact the undersigned. Respectfully submitted SLADDEN ENGINEERING ePOv Ess/%Al� QUO �,� L. ANL7�9S�F2 m Brett L. Andellsohl Principal Engineer C . No. C as`�as �§ XP. 9/30/06 S' CIv1\-P Grading/pc T�TF OF C AL\FO Copies 4/ND La Quinta Partners, LLC ` TEST RESULTS • 3 PROJECT NAME: Hideaway -Area D LOCATION: La Quinta, California PROJECT. NO: 522-2199 y REPORT NO: 03-10-638 Test No. Date Tested Location Elevation Dry Density In Place ' % Moisture In Place Relative "Com' action Maximum Density Building Pads -Via Pontito " 1 9-04-03 Lot 9/10 ,3.0 BPG k 101.4 7.5 91 112'.0 2 9=04-03 Lot 10/11 3.0 BPG 103.7 12.6 93 112.0 3 9-65-03 Lot 2/3 .4.0 BPG 105.4 9.8 94 112.0 4 9-05-03 Lof 2/3 2.0 BPG -100.9 10.1 90 ;112.0 9-05-03 Lot 10 4.0.BPG 111.3 9.9 99 -112.0 6 9-05-03 Lot 10 2.6 BPG 105'.0 8.7 94'- 112.0 ,. T 9-08-03 Lot 6 PG .108.,3 6.7 97 112.0 89-08-03 'LotPG 108.6 5.0 97 112.0 9. ¢_9-08-03 .7 Lot 8 'PG , `105.4.: 9.2. 94 '.112 '.0 .10 9-08-03' Lot 9 PG 107.1 6.4 96 112.0 1'1 •• 9-08-03. Lot 10,' PG `' 103.9 4.9 93 112:0 12. 9-08-03 Lot 11 ' ' PG .106.21 5.4 , 95 112.0 13 9-08-03 s Lot 12 -PG 107.4 5.5 96 • 112.0 14 9-08-03 Lot 13PG 110.9 8.2 99 112.0 15, 9-09-03 Lot 5 PG ,117.0 11.1 ' 99 112.0 16 9-09-03 ., Lot 4 PG' 1.06,7 12.4 95. '112.0 • 17, 9-09-03 Lot 3. PG 111.0 11.1 99 112.0 ' 1.8 9-09-03 . Lot 2 PG -. 109.3 11.1 98 112.0 19 9-09-03 Lot' 1 - PG 110.7 9.91. 99 . • 412.01 1 . 7 DATE: October 3, 2003. t • i Sla(Men Engineering