Loading...
06-4056 (SFD)P.O. BOX 1504 VOIC8.(760) 777-7012 .78-495 CALLE TAMPICO -7011 FAX, (760) 777 LA QUINTA, CALIFORNIA 92253 BUILDING& SAFETY- DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT ate: 4/23/07 Application Number Owner Property Address: RODNEY A MITCHELL APN: .772-410-999-1 1 :-298944- 1544 EUREKA RD #140 Application description: DWELLING - SINGLE' FAMILY DETACHED ROSEVI.LLE, CA 95661 APR 23 2007 Property Zoning:. �LOW DENSITY RESIDENTIAL Application Valuatiom. 478060 Ci F1 OF QUIN NANc DEpr Contracton' �Applicant: Architect or Engineer: GRAYSTONE CONSTRCTION COMPANY C 79405 HIGHWAY ill, SUITE 9-414 LA QUINTA, CA 92253 (760)238-0411 Lic No.. OOR SQUARE FOOT Lic. No. 863749 -------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with ].hereby affirm under penalty of perjury one of the following de . clarations: Section 7000) of Division 3 of the' -Business and Professionals Code, and my License is in full force and effect. I have'and will maintain a certificate of consent to self -insure for workers' compensation, as provided' ,License Class*. B LicenselNo.:. 863749 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Date I have and. will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: - I herel�y affirm under penalty of perjury that I am exempt from.the Contractor's' State License Law for the Carrier STATE FLTND Policy Number 1828934-06 following reason Mac. 7031.5, Business and Professions Code: Any city or county that requires a permit. to I certify that, in the performance of the work for which this permit is issued, I shall not e —ploy any construct, alter, improvei demolish, or repair any structure, prior.to its issuance, also requires the applicant for the person on laws of in any manner so as to become subject to the workers' com�ensati California, - permit to file a signed statement that he or she is licensed pursuant to the provisions ofthe Contractor's State. and agree that; if I should become subject to the workers' compensation provisions -of Section License Law (Chapter 9 (commencing With Section 7000) of.Division 3 of the Business and Professions Code) or 3700 of the Labor Co:d�e',l Zf thwilh c��y with those visions. that he or she isexempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by PV -any applicant for a -permit subjects the applicant to a civil penalty of not more t . han five hundred dollars ($500) Date: pplic.nt:­ 1. as owner of the property, or my employees with wages.as their sole compensation, will do the work,:a:nd the structure is not intended or offered ' for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECUREWORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJE6TAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and -who does the ' work himself or her�elf through his or , her own employees, provided that the DOLLARS 1$ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of -sale.). APPLICANT ACKNOWLEDGEMENT I; as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director.of Building.and Safety for a permit subject to the 7044, Business. and Professions Code; The Contractors' State License Law does not apply. to an ov�ner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with.a c'ontractor(s) licensed 1 Each person upon Whose behalf this'application is made, each person at whose . request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a, result of this application, I am exempt under Sec. B.&P.C. for this reason the owner, and the ipplicant,'each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents.and employees for any act br omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a reslult of this application becomes null and void if work is not commenced within 180 days from.date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that . I have read this application and state,that the . above information is'correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). ..cii y and county . ordinances and state lawsrelating to building construction, and hereby authori ze repre ritatives Lender.'s Name: of th!'s co ty to enter upon the above-mentioned pro e t f cition purposes let '?SigRaturbi(Applicant or. Agent): Lender's Address: LQPERMIT ce Application Number . . . . 06-00004 1 056 Permit BUILD ING PERMIT - Additional desc Permit Fee 1962.50 Plan Check*Fee' . 1275.63 Valuation . . . . Expiratioh-Date 1 10/17/07 Qty Unit Charge Pg r Extension BASE FEE 378 . 00 -------------------- BLDG ----------- 100,001-500,000 --------- -------------------- .639.50 1323.60 Permit . . . . ... ELEC-NEW RESIDENTIAL'-,. .Additional desc Permit Fee 239.74 Plan Check Fee 59.94;, Issue Date Valuation... 0 Expiration Date 1 10/17/07� Qty Unit Charge Per Extension BASE FEE 15.00 5533.00 .0350 ELEC NEW RES 1 OR 2 FAMILY 193.66 804'00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 16.08 1.00 15.0000 - - - - - - - - - - - --- - - - - - 7 EA 'ELEC* - - - - - - - - - - - TEMPORARY POWER POLE - - --- - - - - - - - - - - - ------------------ 15.00 7-7 ------- Permit GRADING PERMIT' - Additional desc'.' Permit. -Fee- 15.-00 Plan Check Fee 1 .00, Issue Date Valuation 0 Expiration Date 10/17/07 Qty Unit..Charge Per. Extension --------------------------------------------------------------------------------- BASE FEE 15.00 Permit MECHANICAL' Additional desc Permit Fee . . . ..150*.50 Plan Check Fee .37.63 Issue Date Valuation u 0 Expiration Date. lb/17/07 Qty' Unit.Charge Per Extension BASE FEE 15.00 5.00 9-.0000 EA MECH FURNACE <=100K 45-.00 �.00- 9.0000 EA MECH B/C <=3HP/100K BTU :6 . 00 6.5000 EA MECH. VENT FAN .45.00 39.00. 1.00 6.5000 - - - - - - - - - - - --- - - - - - - - - - - - - EA MECH -- - - --- --- - - - - EXHAUST I400D --- - - - - - - --- -- - - - - - 7 - - - - - - - - -- - 6 -.-5'0 - - - - - - - LQPERMIT Ile Application Number . . . . . 06-00604056 Permit PLUMBING Additional desc Permit Fee 255.00 Plan Check Fee 63.75 Issue -Date Valuatio n 0 Expiration bate 1,0/17/07 Qty -Unit Charge Per Extension, BASE FEE 15.00 6.0000 EA PLB'F'IXTURE 168 -.00 i.00 15.0000. EA PLB BUILDING SEWER - 1.0b EA -PLB, ROOF DRAIN 6.00 2.00 7.5000 EA PLB.WATER-HEATER/VENT 15.06 EA PLB WATEk-'INST/ALT/REP 3,.00. .1.00 1.00 9.0000 EA LAWN SPRINKLER SYSTEM g.bo 12.00 ..7500. EA PLB GAS.'PIPE >=5 9.00 1.0.0 15.0060 -EA PLB.GAS METER' -- - - - - - - - - - - - - - - - - - - - - - - - 15.00 - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - Spe - cial Notes and Comments - - - - --- - - - - - 55.3.3 sq. ft..sfd this permit does not' include pool &-s a block walls or driveway approacE.Dec-emb" i9,- 2006 11:59:27 AM ..jjohn6on -------------------------------- 7 ------------------------------------------ Other Fees", . ... . . . . . . . ART IN -PUBLIC PLACES -RES. 695.00 DIF COMMUNITY CENTERS -RES' 14.00 DIF.CIVIQ CENTER -RES 995.00 ENERGY REVIEW FEE 127.56 DIF FIRE PROTECTION -RES' 14b.00 GRADING PLAN CHECK FEE 22.'80 DIF LIBRARIES'- RES .355'. 00 DIF PARK.MAINT FAC'_� RES 22.00 DIF­PARKS/REC - RES 892.00 - STRONG MOTION (SMI) RES 47.80 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION 1930.00 'Fee -summary .'Paid Credited. C-harg6d. ---------------- Due 7 ---------- ---------- -------- -7 - Permit Fee Total' �2622.74'. .00. .00 - - - --- 2622.74 Plan Ch6ck Total. 1436.95. '750-. 0.0 .00 '686.§5 Other Fee Total. 5367.86'. .06 .00 5367.,86' Grand Total* 9427.55 750.00 AO '8677.55 LQPERMIT MC GEE S UR VE FING, INC. 79-301 Country Club Dr.; Ste. 102 — Bermuda Dunes, CA 92201 Phone (760) 345-3828 — Fix (760) 772-5705 May 10, 2007 City of La Quinta 78,495 Calle Tampico La Quinta, CA 92253 '00 Re: Pad Certification -3367 Pursuant to your request a field survey was conducted on the above referenced project to determine the vertical location of the building pad. The above mentioned was found a's follows:., LOT ADDRESS PAD (DES) PAD (FIELD) 11 52-958 Via Dona 1006.0! 1006.0'. Sincerely Wa yne McGee HOS L.S. 5479 Al%f- A. LS 5479 F C It RO. BOX 1504 APPLICATION ONLY Building 78-495 CALLE TAMPICO Address 5Z9Si? WAPON4 LA QUINTA, CALIFORNIA 92253 Owner A19 Y IVI I 7_e#!!5 L e ­ Mailing Address eiky- � Q AP& Tel. �4?Se V14- I -E J 9110 7,07/9 MOJ41 Contractor 1�17AA�h(r.712AIA:_ r ress J� Zip Te 1�. State Lic �City & Classif. Lic. # Arch., Engr., D e s i g n e r I\j f 47:2 Address Tel. City Zip State Lic. #6— 2.16 LICENSED CONTRACTOR'S DEC RATIO ,f Chr I hereby affirm that j_aa*�e un 0arovisions c nj r, licmm:�cing with Section 7000) of Divi the Busine ens is in full forcy and effect. OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is lice=rsuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (S500). 0 1, as owner of the property, or my employees with wages as their sole compensation, will do the wo rk, and the structure is not intended or offered lor sale. (Sec. 7044, Business and Profes- sionis Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) 0 1 am exempt under Sec. - B. & PC. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. - Company 0 Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in.the performa w,�rLkforg which this permit is issued, I shall not employ any person in any manni to eco bject to Work ation Laws of Calif ' ;;�� :�, D 1�ner N ICE TO AlOPLICANT.- If, after_mR'ng this Certificate of Exem'ption you should become subject to the Workers' Compensation provisions of the Labor code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is sus pended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize re P7 sentatives of this city to enter the above-mentioned property for inspection purposes. I I A Signature of applicant lz V .1 of V Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST— OCC. GRP A.R Number -7-77 —4/-0 Legal Description Kojecit Descriptibn 4— Sq. F No. No. Dw. Size it �-.3?2 Stories Units Newx Add 0 Alter 0 Repair 0 Demolition 0 0 Estimated Valuation PERMIT MOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure 91 TOTAL if REMARKS CW ZONE: BY.. Minimum Setback Distances: Front Setback from Center Line --Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:— Validated by: I Validation: YELLOW = APPLICANT Date- Permit PINK = FINANCE Coachella Valley -Unified Sthool District This Box'For District'Use Only '83-733 Avenue 55, Thermal, CA 92274 DEVEWPER FEES PAM .(760) 398-5909 — Fax (760) 398-1224. AREA: A40UNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: 'DATE: RECEIM CHECK #: INITIAL& CERTIFICATE OF COMPLIANCE (California Educali6n Code 17620) Project Name: Residence is at tl Date: April 23, 2007 Owner'sName: _R6dneyMitchell Phone No. Project Address:. - 52-958 Via Dona La Quinta, CA Project Description: I SFD APN 777-4 10-0 11-4 Trac t Lot #'s: Type of Development. Residential XX Commercial Total Square Feet of Building Area: 5,533 sq. ft. ertification of Applicant/Owners: The person sigmng certifies that the above information is correct and make's this statement under penalty of perjury and further'represents that he/she. is'authorized to sign on behalf of the ownek/developer, Dated: April 23,'2007 Sig hatur e: -SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN 'ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 6.5995 - Approval PrioF to 1/1/87 Note - Number of Sq.Ft. 5,�33. Amount per Sq.Ft. $3.91 Amount Collected $2'1,634.03 Building Permit Application Completed: Yes/N6 By:, Carey M. Carlson, Asst. Supi., Business Services % Certificate issued by: Elvira Mattson, Office 'Technician, Signature - NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES, Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a Written I notice to the project appellant,, at the time of 'payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest -the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to �uch Fees or the validity thereof, �ommences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whol e or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days.start ' s on the'date hereof. This Certificate * of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, asdetermined by the School District, and up, to three (3) such extensions may be granted. At such time as this Certificate ex ' pires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to.obtain this.Certificate of Compliance. MV:c/nivdocs/de�,fe�s/certificate of compliance fOl'hl Updated 33-2007 3/9/07 Certificate of Occupancy BVilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance ' this structure was in compliance with the provisions of the Building Code and the various ordinances of the Cit regulatin building y 9 construction andlor use. BUILDING ADDRESS: 52-958 VIA DONA Use classification: SINGLE FAMILY DWELLING Occupancy Group: R-3 Owner of Building: RODNEY A MITCHELL Building Official Type of Construction: VN Building Permit No.: 06-4056 Land Use Zone:,RL Addtess:'1544 EUREKA RD #140 POST IN A CONSPICUOUS PLACE City, ST, ZIP: ROSEVILLE, CA 95661 By: A.J. ORTEGA Date: MARCH 5,2008 TITLE 24 REPORT Title 24 Report for: Mitchell Residence 52958 Via Dona La Quinta, CA 92253 Project Designer: RAM Companies 1544 Eureka Rd #140 Roseville, CA 95661 916-789-1400 Report Prepared By: Sheila Munson Eagle Quest Specialties, Inc. 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 CITY OF LA QUINTA ILDING 8, SAFEV DEPT. BU APPROVED TIUCTION FOR cONS Job Number: DAT Date: NO V 8/30/2006 Z,200& 'he EnergyPro computer program has been used to perform the calculations summarized in this comp ia ce report. This progr -has approval and is by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy fficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by Energysoft Job Number: User Number: 5862 e� r . * ., r F • � N!. f' Certificate Of Compliance : Residential (Part 1 of 4) . CF:1 R -AWitrbe1LRe.sid.en.c Insulation Act. New- A/ gnn(3 -Wrofect Title -52-9 5-83fiaJD on-a-La-0winta Area:' 1,869 ft2 Avg. U: Date Project Address -Wall - -6Z5 Ratio: 36.7% Building Permit # i-e-st-Spe-cialties,lac Docn'm;en tion Author Number of Stories: (760) 345-4859 Telephone lUILDING ZONE INFORMATION Plan Check/Date -EnejnvPro Compligtice Method # of 15 Climate Zone one Name Field Check/Date Volume TDV Standard Proposed Compliance 1 S7 (kBtu rsf-yr) Design Design Margin Raof-- Wood- 2 6 2- Space Heating 2.85 1.75 1.10 -LLvjng.S.tat- Space Cooling 62.68 62.90 -0.21 -0JJ- -C-onditimed- -Setback- Fans 9.47 10.14 -0.67 Wall Wood- ----215- Domestic Hot Water 5.04 4.59 0.45 -0.069- R-91 -R--GA---225--90 Pumps 0.00 0.00 0.00 Totals 80.05 79.38 0.67 F-looL- Wood- -359- Building Type: [X-] Single Family El Multi Family Building Front Orientation: FuelType: El Addition El Existing + Add/Alt (W) 270 deg Natural Gas Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Insulation Act. New- Average Ceiling Height: U -Fac. Cay. Cont. Azm. Area:' 1,869 ft2 Avg. U: 0.37 Number of Dwelling Units: -Wall - -6Z5 Ratio: 36.7% Avg. SHGC: 0.33 Number of Stories: -'90 lUILDING ZONE INFORMATION -0-069- --R--21- -ELO-0- 135-90 -O.q-AR # of Thermostat one Name Floor Area Volume Units Zone Type Type Master-S-14te & edrooms 1 S7 -1-7_347 -O-3J- leeping -SleepingStat- Raof-- Wood- 2 6 2- -----2-9AI -36,Z62 -0-58- Lmy�nq -LLvjng.S.tat- -2 jo -57-5. -517-5 -0JJ- -C-onditimed- -Setback- OPAQUE SURFACES Insulation Act. New- Type Frame Area U -Fac. Cay. Cont. Azm. Tilt ROOL- Wood- ---1-497- -0-029- -J�U8- -R--DA -0- New- New- New- New- Ne.w- -Wall - -6Z5 0-069 -R�-21 --R--0-0- -0--90 - -Wall Wood- 8-4- -0.069 -R--2J- --R=0-0- -9.0- -'90 -Wall Wood- 25- -0-069- --R--21- -ELO-0- 135-90 -O.q-AR -Wall Wood- 265 -0.069- -R=a --R--O-O- -180- -90 -Wall Wood- -56- -0-069- -aM- --R-0-0- 225-90 -09--A6- -Wall Wood- 295- -0.069- ---R--2J- -R--O-O- 9Z0--9.0 28-A4 -Wall Wood- -44- -0-069- --a-2-1- --R--O-O- -3-15--90 21 -A4 Raof-- Wood- 2 6 2- -0-029- -R--38- --R--O-O- -0--0 91-A4 Wall- ZtQod- -3-17- -0 069 -R-21 -R-0-0 -0 90 Wall Wood- -3-46- -0-069- R-21 -R-0-0--90--90 - 6 -WAII Wood ----26- -0-069- -R--21 -R-0-0- -135-90 -Q9--A6- Wall Wood- ----215- -0-069- R-21 -B-OA--180--90 - -Wall Wo-od- ---25- -0.069- R-91 -R--GA---225--90 -0-9--A6- Wall Wood- 586 -0-069- R-21 --R--O-O---2ZO--9,0 -DooL-- Noiie- 24 -0 5.0.0- -None- -R--O-O- ----2ZO--9,0, F-looL- Wood- -359- -0-0-4.8- -aA9- -R--0-0- -0- 1 0 Eo.or Waod 21.6- -0-0-48- --R--19- --R--O-O- -0- 180 RooL- Wood -575- -0-029- -R--38- -ELO-0- -0--0 -Wall Wood- -3-40- -0.069- -R--2-1- -ELO-0- -0--90 -Wall- Wood- -7-6- -0-069- -RL2-1- -R-0 -0- -9.0--90 -Wall- Wood- -3.31 -0-0-69- R-91 -13--0-0- ---18-0--9-0, Wood- -220- -0.069- -R--2A --R--0-0- 27090 5,093 ft2 n/a ft2 575 ft2 4,518 ft2 11.6 ft 1.00 Vent Hgt. Area n/a -n/a -n1a Gains Condition Y/N Status JA IV Reference Location / Comments New- -02--AJJ- -Master-&-Bedroomn New- -09--A6- MasteL&-Bedroo New- New- -Master-&-Red Master -&-Bedrooms New- New- New- New- Ne.w- -Master-&-Redro-orns Master-&-B-edrooms -0.9--A6- Allaster-&-Bedro.oms -0.9--A6- -MasteL&-Bed rooms -0.2--Al-l- living New- - 1LvJng New- -O-q--A6- Living New- -O.q-AR - Living New- New- -09--A6- -09--A6- Uving ILving New- -09--A6- -LMng New- 28-A4 .1-Ning New- 21 -A4 2nd-E]OOL&-Studin New- 91-A4 2nd-Ooor-&-Studen New- -02-Al 1 2nd-FJGOL&-S.tudi New- - 6 2nd-Eloor-&-S.tud*10_ New- -Q9--A6- 2nd-Ooor-&-S.tud i New- - 2nd-Eloor-&-Studi N.e.w- -0-9--A6- 2nd-S.o-or-&-Studi EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Paqe: 3 of 32 1 Certificate Of Compliance : Residential (Part 2 of 4) CF:1 R ftitchell Residence 8/30/2006 'MPProject Title Date FENESTRATION SURFACES 2 True Cond. Location/ # Type Area U -Factor' SHGC Azrn. Tilt Stat. Glazing Type Comments -1- -ftndow-Left-(N) 2 Window Left _UN _ -9-0 21.2 0-370 NERC -0-33 -NEPC 0.370 NFRQ 0.33 NFRQ -0- 0 90 New-Maad atory-Minim um 90 New _Mandato�y Minimum -MasteT-&B.e.dmoms- Master & Bedrooms 3 Window Left _UN _ 21.2 0.370 NFRQ 0.33 NFRQ 0 90 New _Mandato[y. Minimum Master & Bedrooms 4 Window Left (N) 9.0 0.370 NFRC 0.33 NFRC 0 90 New _Mandato[y Minimum Master& Bedrooms 5 Window Left -fNL 24.0 0.370 NFRQ 0.33 NFRQ 0 90 New -Mandato Minimum Master & Bedrooms 6 Window Left -UN 9.0 0.370 NFRQ 0.33 NFRQ 0 90 New Minimum Master & Bedrooms 7 Window Left (N)- 31.1 .-0-33 NFR-C --U70 NFRC 0 -Mandato 90 New Ma -ad at Minimum Ka­sle-r -& Bed rQoms-- 8 Window Left (N) 25.0 0.370 NFRC 0.33 NFRC 0 90 New _Mandato[y Minimum Master& Bedrooms -9- Wind w ReaL-(E)- 0.76 72.2 -0=1 NFRC -O-U NERQ --9-0- -K bhe3k-Manda Minimum Master & Be-d-rq-Qw- J-0 Window Rear -(-E)- 34.2 0.37 NERC 0,33 NFRC 90 90 New Minimum -Ka­st-eb&-Be­drooms- 11 Window Rear _(E)- 85.0 0.370 NFRQ 0.33 NFRQ 90 90 New -Mandatory Minimum Master & Bedrooms 12 Window Rear -LEJ- 14.8 0.370 NFRC 0.33 NFRQ 90 90 New _Mandato[y. Minimum Master & Bedrooms A-3 14 -WjncLow--Rear-(E)- Window Rear _(5Q 4 Z 14.8 -0-370 BE R -C 0-33 BERC 0.370 NFRQ 0.33 NFRQ -90- 135 -90- Rew-Mandato.r�LlAinirnum- 90 New -Mandato[y Minimum -mas.tef-&Bedworns- Master & Bedrooms 15 Window Rear !jE _L _) 4.7 0.370 NFRC 0.33 NFRC 135 90 New _Mandatory Minimum Master & Bedrooms 16 Window Right (S) 14.8 0.370 NFRQ 0.33 NFRC 180 90 New MandatoN Minimum Master& Bedrooms 17 Window Ri ILt__(5j_ Condition 4.7 0.370 NFRC 0.33 -NERC. 180 90 New Mandato!y Minimum Master & Bedrooms 18 Window Right (S) 34.0 0.370 NFRC 0.33 NFRQ 180 90 New Mandato[y Minimum Master & Bedrooms 19 Window--R-ig-ht-(5)- --3A.-Q -D-aLO NERC -Q.-U -RE-RC 180 90 New n Minim nn Ma r & B rooms - 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. Living / Slab on Grade INTERIOR AND EXTERIOR SHADING Window Overhang- Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bu Screen 0.76 y Bu Screen 0.76 3 Buq Screen 0.76 aBug Screen 0.76 u Bug Screen 0.76 6 Bug Screen 0.76 7- �uq Screen 0.76 8 Bug Screen 0.76 T Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen -i -2 'Bug 0.76 Screen 0.76 �-3 Bug Screen 0.76 T4 'Bu Screen 'Bug 0.76 T5 Screen -076 1-6 Bug Screen 0.76 T7 _�jug_�creen 0.76 18 Bug Screen 0.76 T9 'Bug Screen 0.76 8.5 4.0 0.1 2.0 0 0.0 0.0 0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, HeayMei-ght 457 4.00 28 0.98 0 26 -Al New Master & Bedrooms / Slab on Grade Concrete, Heavyweight 1,12 4.00 28 0.98 - 2 26 -Al New Master & Bedrooms / Slab on Grade Concrete-Ij �aeight 2,68 4.00 28 0.98 0 26 -Al New Living / Slab on Grade Concrelg_Heavyweight 252 4.00 28 0.98 2 26 -Al New Living / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 68 None No Insulation 26 -Al New Master & Bedrooms Slab Perimeter 128 None No Insulation 26 -Al New Master & Bedrooms Adftab Perimeter 237 None No Insulation 26 -Al New Living 12 None No Insulation 26 -Al New Living Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 4 of 32 - -;I �r Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R ell Title 8/30/2006 Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 20. 21 W_tndow_Bight_(.S_W) Window Right (SW) 14.8_ 4.7 _0_37-0 _NERC _0..3.3 _NERC _225_ 0.370 NFRC 0_33 NFRC 225 _90- New Mandato -Minimum 90 New Mandatory Minimum _MasteL&-Bedroom. s Master & Bedrooms 22 Window Right (U 24.0 0.370 NFRC 0_33 NFRC 225 90 New Mandatory Minimum Master & Bedrooms 23 Window Front (W) 72.2 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum Master & Bedrooms 24 Window Left (N) 24.0 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum Livin 25 Window Left (N)_ 55.2 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum Living Window Left (W 15.1 X37_0 NFRC_ 0 NFRC_ 901New M_arldatSZry_Minimum Living 27 Window Left (NN 38.9 0.370 NFRC 0.33 NFRC 0 90 New Mandatory Minimum Living 28 Window ReaL_(E)_ _61 Z -D-37-0 NFRC 0 3 _NF_RC 90 90_ New Mandsnt4ly Minimum Living .29 Window Rear (E)_ 72.2 0.370 NFRC 0 3 NERC 90_ 90 New Massial2ry, Minimum Living 30 Window Rear (E) 19.8 0.370 NFRC 0_33 NFRC 90 90 New Mandatory Minimum Living 31 Window Rear (Ej 111.8 0.370 NFRC 0_33 NFRC 90 90 New Mandatory. Minimum Livin 32. 33 W_irdow_Rear(E)_ Window Rear (E) -30-3 72.2 0 3Z0_NERC 0.33 _NF_RC _90_ 0.370 NFRC 0_33 NFRC 90 _90 Ne -w M.andatoiy-Min.ir.um 90 New Mandatory Minimum _Living Livinq 34 Window Rear (E)_ 19.8 0.370 NFRC 0_33 NFRC 90 90 New Mandatory Minimum Living 35 Window Rear (E) 30.3 0.370 NFRC 0_33 NFRC 90 90 New Mandatory Minimum Livinq 36 Window Rear (E) 24.0 0.370 NFRC 0_33 .NERC. 90 90 New Mandatory Minimum Living 37 Window Rear (SEZ 24.0 0.370 NFRC 0_33 NFRC 135 90 New Mandatory Minimum Living 38 Window Right (S) 1.2 0.370 NFRC 0_3 NFRC __1$0_ 90 New Mandatory Minimum Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 Ti Bug Screen 0.76 22 Bug Screen 0.76 8.0 3.0 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 4 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 12.3 5.0 0.1 4.0 0 0.0 0.0 0 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 2.3 13.0 10.0 0.1 10.0 10.0 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 0.0 0.0 0 0.1 4.0 0 37 Bug Screen 0.76 38 Bug Screen 0.76 0.6 0.6 10.0 0.1 10.0 10.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 08/30/06 11:41:50 Run Code: 1156963310 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:5 of 32 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R itchell Residence 8/30/2006 roject Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazin4 Type Comments _39--l_bd.ow-- Right_(.S.)_ 40 Window Right U_ 1..2. 1.2 -0.370-NERC-0-3.3 0.370 NFRC 0_33 NFRC 1.8.0__9.0_New 180 Mandato.- inim.um 90 New Mandatory Minimum _Living Living 41 Window Right (S)_ 28.0 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum Livin 42 Window Right i_ 58.5 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum Living 43 Window Right (S�_ 55.2 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum Living 44 Window Right P_ 15.1 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum Living 46 �IVd4�[orlt-(W)_ Window Front (W) 36 Q 36.0 =0 NFRC 33 1C 0.370 NFRC 0_33 NFRC 270 �Q New Mand Minimum 90 New Mandatory MinimumLiving Living AZ Win_d9w Front (W)_ 6.8 -D_3-7-0 NFRC 0-D NERC ---2Z0_ 90 New MAndatQrylyl.in.itnum Living Aa Aq Window Front (W)_ Window Front (W)_ 6A 29.8 X310 NF C 0-35 NERC 0.370 NFRC 0_33 NFRC 270_ 270 9Q New Mandatory Minimum 90 New Mandatory Minimum Usti Living 50 Window Front (W)_ 10.5 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum Livin 51 52 -Windowr Er_ont_(W)_ Window Front (W)_ 36_0 6.8 0 37.0 _NFRC _0_33 _N.ERC 0.370 NFRC 0_33 NFRC _2.7_0_ 270 _90- New 90 New Mandator: JL inimum Mandatory Minimum _Living Living 53 Window Front (W)_ 36.0 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum Living 54 Window Front (_W) 6.8 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum Living 55 Window Front (W)_ 36.0 0.370 NFRC 0_33 _NF2C. 270 90 New Mandatory Minimum Living 56 Window Front (W)_ 6.8 0.370 NFRC 0_33 NFRC 270 90 New MandatoryMinimum Living 51 Window ront_(W)_ ---19_0- 310 NFRC 035 NFRC -0--9k New ManS1�t4[y Minimum Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 0.6 0.6 10.0 0.1 10.0 10.0 40 Bug Screen 0.76 0.6 0.6 10.0 0.1 10.0 10.0 41 Bug Screen 0.76 Buq Screen 0.76 0 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 8.0 4.5 0.1 2.0 0 0.1 2.0 0 46 Bug Screen 0.76 8.0 4.5 0.1 2.0 0 0.1 2.0 0 47 Bug Screen 0.76 1.5 4.5 8.0 0.1 8.0 8.0 0.1 2.0 0 0.1 2.0 0 48 Bug Screen 0.76 1.5 4.5 8.0 0.1 8.0 8.0 0.1 2.0 0 0.1 2.0 0 49 Bug Screen 0.76 8.5 3.5 0.1 4.0 0 0.1 4.0 0 50 Bug Screen 0.76 1.5 7.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.1 4.0 0 51 Bug Screen 0.76 8.0 4.5 0.1 2.0 0 0.1 2.0 0 52 Bug Screen 0.76 1.5 4.5 8.0 0.1 8.0 8.0 0.1 2.0 0 0.1 2.0 0 53 Bug Screen 0.76 8.0 4.5 0.1 2.0 0 0.1 2.0 0 54 Bug Screen 0.76 1.5 4.5 8.0 0.1 8.0 8.0 0.1 2.0 0 0.1 2.0 0 55 Bug Screen 0.76 8.0 4.5 0.1 2.0 0 0.1 2.0 0 56 Bug Screen 0.76 1.5 4.5 8.0 0.1 8.0 8.0 0.1 2.0 0 0.1 2.0 0 57 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Le Insulation R -Val. Location Condition JA IV Reference Status Location/ Comments Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 32 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Aft Itchell Residence 8/30/2006 roject Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments _5.8. Window_Eront_(.1N)_ 42.2. _0...370 _NERC 0_3.3 -NERC _2.7.0_ _90_ Never Maadato4-Nrum.um living 59 Window Left (L4)_ 9.0 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum 2nd Floor & Studio 60 Window Left (NJ- 9.0 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum 2nd Floor & Studio 61 Window Left (N) 9.0 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum 2nd Floor & Studio 62 Window Left (N) 20.2 0.370 NFRC 0_33 NFRC 0 90 New Mandatory Minimum 2nd Floor & Studio 63 Window Rear (E)- 27.7 0.370 NFRC 0_33 NFRC 90 90 New Mandatory Minimum 2nd Floor & Studio SZ4 Window Rear (E)_ 27.7 -03ZONE6_C 0.33 NFRC 90 94 New MADjdak9sy Minimum 2nd Floor & Studio 65 Window Rear (E) 21.0 0.370 NFRC 0.33 NFRC 90 90 New Mandatory Minimum 2nd Floor & Studio 66 Window L1k_(.S)_ 1.2 QL370 NERC 0-33 1� FRC 1$Q- 99 New Mandatory i i um �d Floor &Studio 67- Window Riaht_($)_ 1.2 QUO NFRC 0U3 NFRC 180 9Q New Mandatory Minimum 2nd Floor & Studio 68 Window Right (S)_ 1.2 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum 2nd Floor & Studio 69 Window Right (S)_ 25.2 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum 2nd Floor & Studio 10 71 Wiadow--- Bight_(.S)_ Window Right ($) 9.0 9.0 0337-0 _NEB.0 -0.3.3 _NEB.0 0.370 NFRC 0_33 NFRC 1-80_ 180 _90- New Maad.atoryJMin.imum 90 New Mandatory. Minimum _2nd-aoor_& Studio 2nd Floor & Studio 72 Window Right (S)_ 9.0 0.370 NFRC 0_33 NFRC 180 90 New Mandatory Minimum 2nd Floor & Studio 73 Window Front (W)_ 9.0 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum 2nd Floor & Studio 74 Window Front (W) 9.0 0.370 NFRC 0_33 _NERC. 270 90 New Mandatory Minimum 2nd Floor & Studio 75 Window Front U_ 9.0 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum 2nd Floor & Studio ]rz Window FroOt_(W) 1.2 Q_3Z0 NFRC 36 NFRC 227 90- New Ua di3t9sy Minimum ?[Ld_F_lo-Qr_&-atudio 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 W21 Bug Screen 0.76 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 4.5 4.7 0.1 4.0 0 0.0 0.0 0 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 72 Bug Screen 0.76 73 Bug Screen 0.76 74 Bug Screen 0.76 75 Bug Screen 0.76 76 Bun Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments r� i� Run Initiation Time: 08130106 11:41:50 Run Code: 1156963310 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:7 of 32 i Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R �Itchell Residence oject Title 8/30/2006 Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 17 Window---Eront_(.W)_ 1.2. _0..37 -0 -NERC _0_33 NFRC —2-Z0_ 78 Window Front (W) 1.2 '0.370 NFRC 0_33 NFRC _90_ Raw—Mandatory—Minimum 270 90 New Mandatory Minimum 2nd-So-or_&Studio 2nd Floor & Studio 79 Window Front (W 1.2 0.370 NFRC 0_33 NFRC 270 90 New Mandatory Minimum 2nd Floor & Studio' 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang "Left Fin # Exterior Shade Type - SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. 77 Bug Screen 0.76 78 ,. Bug Screen 0.76 79 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ .Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments" PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Right Fin Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310 EnergPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:8 of 32 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R PItchell Residence 'Project Title Date 8/30/2006 HVAC SYSTEMS Location Heating ; Type Minimum Eff Cooling Type Minimum Eff Condition Status Thermostat Type Master Suite & Bedrooms Central Furnace 80% AFUE Split Air C66ditioner 13.0 SEER New Setback Living Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback 2nd Floor & Studio Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status. Tested? Master Suite & Bedrooms Ducted Ducted Attic 6.0 New Yes Living Ducted Ducted Attic 6.0 New Yes 2nd Floor & Studio Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length - Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater - # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. A.O. SMITH GVR-50 Small Gas All Pipes Ins 1 40,000 50 • New 0.62 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Control # HP Type `Hot Water Piping Length U Add 1/2" In Plenum Outside Buried ' Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. . Designer or Owner (per Business & Professions Code) Name: �;ke. G2neo i Title/Firm: RAM Companies Address: 1544 Eureka Rd #140 Roseville, CA 95661 Telephone: 916-789-1400 Lic. M G 2 (signature) (dat Enforcement Agency Name: Title/Firm: ,dress: lephone: Documentation Author Name: Sheila Munson Title/Firm: Eagle Quest Specialties, Inc. Address: 42335 Washington Suite F #330 Palm Desert, CA 92211 Telephone: _(760) 3454859 �3 (signatur ( ate) (signature/stamp) of 32 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 8/30/2006 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. he HVAC System "Master Suite & Bedrooms" incorporates HERS verified Duct Leakage. Target leakage is calculated and ocumented on the CF4R. The HVAC System "Master Suite & Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas HIGH MASS Design - Verify Thermal Mass: 457 sgft Exposed Slab Floor, 4.00" thick at Master Suite & Bedrooms HIGH MASS Design -Verify Thermal Mass: 1120 sgft Covered Slab Floor, 4.00" thick at Master Suite & Bedrooms This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The HVAC System "Living" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design - Verify Thermal Mass: 2689 sgft Exposed Slab Floor, 4.00" thick at Living HIGH MASS Design - Verify Thermal Mass: 252 sgft Covered Slab Floor, 4.00" thick at Living The HVAC System "Living" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Living" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System 'TRANE 4TTX4060fTUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "2nd Floor & Studio" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approves ncma proviaer using ,c;, approveu tesung anaior vermcauon metnoas ano must oe reporteo on the Lr -4K installation certificate. Plan Field he HVAC System "Master Suite & Bedrooms" incorporates HERS verified Duct Leakage. Target leakage is calculated and ocumented on the CF4R. The HVAC System "Master Suite & Bedrooms" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System 'TRANE 4TTX4060/TUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Living" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Living" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System 'TRANE 4TTX4060fTUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "2nd Floor & Studio" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "2nd Floor & Studio" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System 'TRANE 4TTX4030/TUD60R936 " includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. 0 I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 10 of 32 I Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise • residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown' elsewhere in the documents or on this checklist only. r a DESCRIPTION' Check or initial applicable boxes or check NA if not applicable and included with the ' ENFORCE - permit application documentation.. N/A DESIGNER MENT Building Envelope Measures f§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ . ❑ ❑ '§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ Q ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ _. ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation -water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ; • ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El a El Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. i ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient infiltration ❑ 0 ❑ (SHGC), and certification. + 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ :: ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC, equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation El - ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. , 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. r 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 11 of 32 W Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent • compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ x❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ x❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ x❑ ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR by dimmer OR ❑ x❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ x❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ` § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ x❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires: Up to 50% of the Wattage, as determined ❑ ❑x ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ x❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR by dimmer OR ❑ x❑ ❑ are controlled a switch are controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ x❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ x❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by Energysoft User Number: 5862 Job Number: Page: 12 of 32 Residential Kitchen Lighting Worksheet • WS -5R aitchell Residence 8/30/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire-Type High Efficacy? Watts Quantity Watts Other Watts (1) 5" Circling Yes X - No 15.0 x 21 = 315 or 35w Recessed Incandescent Yes, No X '35.0 x 4 = or '140 35w Recessed SPOT Incandescent Yes No X 35.0 x 5 = or 175' Yes No x = or Yes No x _ or Yes No x or - Yes No x = or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x- or ` Yes No x _ or Yes No x = or Yes No x = or, Yes No= r _ x or. Yes No x = or; .. Yes No x = or Yes No x = or Yes No x = or t .Total A:. 315 B: 315. COMPLIES IF Az B YES[i] NOO e i ,'• a •. t EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 32 LHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY diROJECT NAME DATE Mitchell Residence 8/30/2006 SYSTEM NAME FLOOR AREA Master Suite & Bedrooms 1,577 Number of Systems I Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating System Output per System 79,000 Total Output (Btuh) 79,000 Output (Btuhlsgft) 50.1 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 36.8 Total Output (sgft/Ton) 326.3 Air bystem CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfmisgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRI COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,647 29,794 857 759 28,275 0 2,705 2,252 0 0 115 4,615 -96 115 5,255 0 0 2,705 2,252 39,8191 76 e,vvv 2,000 TRANE 4TTX4060/TU D 1 0OR960 (5) 45,095 4,032 1.27 413.8 5 8 Total Adjusted System Output 45,095 4,032 (Adjusted for Peak Design Conditions) 0.07 TIME OF SYSTEM PEAK Aug 2 pm T 26.0 of 66.5 of 66.5 of n 105.0 of Outside Air 115 cfm 68.9 of 11.0 / 72.5 of Outside Air 115 cfm 3/60.9 of 0, Supply Fan Heating Coil 2000 cfm 75.4 / 61.6 of O k Return Air Ducts `S Temperatures at Time of Coo 754/R17OF 1 Kirin/-i'iQOF Supply Fan 2000 cfm 79,000 79,000 Jan 12 am Supply Air Ducts 103.9 of ROOMS 70.0 OF Supply Air Ducts Cooling Coil 56.3 / 54.4 of 51.6% R.H. ROOMS 72.0 ! 60.5 of Return Air Ducts I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:14 of 32 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY itROJECT NAME DATE Mitchell Residence 8/30/2006 SYSTEM NAME FLOOR AREA Living 2,941 lNumber of Systems 21 Heatina Svstem Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRI 79,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 158,000 53.7 Latent 58,000 116,000 9.7 26.0 of 67.9 of 67.9 of Outside Air 115 cfm 69.1 of 3I TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,984 53,994 906 1,245 46,364 0 4,902 3,693 0 0 115 4,630 -83 115 5,279 0 0 4,902 3,693 68,428 824 59,028 L,vvv 4,000 TRANE 4TTX4060/TUD100R960 (5) 87,397 . 10,182 158,000 1.36 413.8 1.92 Total Adjusted System Output 10,182(Adjusted for Peak Design Conditions)g7397 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Supply Fan Heating Coil 4000 cfm of Heati in Return Air Ducts 4 Supply Air Ducts 104.1 of ROOMS 70.0 of COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/72.5OF 74.2/61.2OF 74.2/61.3OF 55.0/53.9OF O Supply Air Ducts Outside Air 115 cfm Supply Fan Cooling Coil 56.2 / 54.4 of 4000 cfm 51.4% R.H. ROOMS 73.2 / 60.8 of 72.0 / 60.4 of h Return Air Ducts 4 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Paae:15 of 32 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY �ROJECT NAME DATE Mitchell Residence 8/30/2006 SYSTEM NAME FLOOR AREA 2nd Floor &Studio 575 Number of Systems I 11 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating System Output per System 52,000 Total Output (Btuh) 52,000 Output (Btuh/sgft) 90.4 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 41.7 Total Output (sgft/Ton) 287.5 F— r Y. em 800 Airflow (cfm) Sensible 800 Airflow (cfm/sgft) I Sensible 1.39 Airflow (cfm/Ton) 1,264 400.0 Outside Air (%) 0 14.4 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 769 13,920 82 1 288 10,740 0 1,264 855 0 0 115 4,589 105 115 5,262 0 0 1,264 855 21,036 715 17 713 TRANE 4TTX4030/rUD60R936 20,438 264 Total Adjusted System Output (Adjusted for Peak Design Conditions) 20,438 264 52,000 52,000 Outside Air (cfm/sgft) 0.20 TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 26.0 of 62.8 of 62.8 of 105.0 of Outside Air 0 115 cfm Supply Fan Heating Coil 800 cfm 69.0 of K Return Air Ducts 4 Supply Air Ducts 104.0 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/72.5OF 78.9/62.8OF 78.9/62.8OF 55.0/53.7OF t� Supply Air Ducts Outside Air 115 cfm Supply Fan Cooling Coil 56.5 / 54.3 of 800 cfm 51.7% R.H. ROOMS 73.5/61.00F 1 72.0/60.5 OF k Return Air Ducts `i EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 16 of 32 1 ROOM LOAD SUMMARY 4RO1ECT NAME Mitchell Residence DATE 8/30/2006 SYSTEM NAME Master Suite & Bedrooms FLOOR AREA 1,577 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM ISENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master & Bedrooms Master Suite & Bedrooms 1 1,647 29,794 857 1,647 29,794 857 759 28,275 . J } s , j A. PAGE TOTAL 1 1,647 29,794 857 759 28,275 ' TOTAL 1 1,647 29,794 857 759 28,275 EnergyPro By EnergySoft User Number: User Job Number: Page:17 of 32 ROOM LOAD SUMMARY d�ROJECT NAME DATE Mitchell Residence .8/30/2006 SYSTEM NAME FLOOR AREA Living 2,941 4 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Living 1 2,984 53,994 906 2,984 53,994 906 1,245 46,364 PAGE TOTAL 1 2,984 53,994 906 1,245 46,364 TOTAL 1 2,984 53,994 906 1,245 46,364 EnergyPro By EnergySoft User Number: User Job Number: Page:18 of 32 ROOM LOAD SUMMARY 9 ROJECT NAME , Mitchell Residence DATE 8/30/2006 SYSTEM NAME . 2nd Floor & Studio FLOOR AREA 575 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE 2nd Floor & Studio 2ns Floor & Studio 1 769 13,920 821 769 13,920 821 288 10,740 1 PAGE TOTAL 1 769 13,920 a21 288 10,740 TOTAL 1 769 13,920 821 288 10,740 EnergyPro By EnergySoft User Number: User Job Number: Page: 19 of 32 ROOM HEATING PEAK LOADS I roject Title Mitchell Residence n/gnnR Room Information Desi n Conditions Room Name Master suite & Time of Peak Jan 12 am Floor Area Bedrip Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF = = = = = = = = = = = = = = = = = = = = = = = = = = = Conduction R-38 Roof R.38.2x14.16 R-21 Wall W.21.2x6.16 andatoiyMinimu .. Mandatory Minimum Mandatory -Minimum Mandatory Minimum Mand' ry Minimum Mandatory Minimum andatonjMinimum Mandato Minimum R--2J-Wall (W.21 -2x6 16 Mandatory Minimum Mandato Minimum Mandatocy Minimum an.dato"inim.0 Mandato4-Mnimum R-Z1-Wc-dl-(W-2-1-2x6-1-6) �ilaQday Minimum andato Minimum R - 2J -Wall (W.. 912x6 16) andatory Minimum Mandato Minimum Mandatory Minimum Mand story Mini' - LV�LaIL(lL1L.2]-.2x6 _t6a Mandatory Minimum amdaSQryMau imu Mandatory-Minimu - Wall 212x6-.6. andato"inimu .. R-21 Wall .21.2x6.16 Slab=On=Grade Slab -On -Grade U -Value Items shown with an asterisk (') denote conduction through an interiors . urface to another room. Page Total: 22 471 Infiltration: r 1.001 X 1.064 X 1 577 X 1"1.00 X 0.429 / 6] X 44 = 5 804 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28,275 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 20 or 32 1497.0 X x X X X X X x X x X X X X x X x x X x X X X X X X X x X x x x X X X X X X X 0.0290 X X X X X X X X X X X x X X x x x x X x x X x x X X x x X x x X X X x x X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,910 675.4 0.0690 44 2,050 9.0 0.3700 44 147 21.2 0.3700 44 346 21.2 0.3700 44 346 9.0 0.3700 44 147 24.0 0.3700 44 391 9.0 0.3700 44 147 311 0.3700 44 506 25.0 0.3700 44 407 284.2 0.0690 44 1,176 72.2 0.3700 44 34.2 0.3700 44 556 85.0 0.3700 44= 1,384 14.8 0.3700 44 0 4.7 0.3700 76 2.4_6 14.8 0-0690 0.3700 4-4 44=240 5 4.7 0.3700 44 76 264.6 0.0690 44 803 4 0,3700 4 0 4.7 0.3700 44 76 34.0 0.3700 44 554 34.0 0.3700 44=554 55.6 0.0690 169 14.8 0.3700 44 240 4.7 0.3700 44 76 24.0 0...3ZQ0 39J 68 4.8- _0.69.0 44 72.2 0.3700. J; 44.0 0.0690 44 1-3.4 2184 perimeter = 68.0 0.7300 44 perimeter = 128.0 0.7300 44 4,111 Items shown with an asterisk (') denote conduction through an interiors . urface to another room. Page Total: 22 471 Infiltration: r 1.001 X 1.064 X 1 577 X 1"1.00 X 0.429 / 6] X 44 = 5 804 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28,275 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 20 or 32 ROOM HEATING PEAK LOADS roject Title Date itrhPll ResifiPnrp R/. SMF Room information Desicin Conditions Room Name Living Time of Peak Jan 12 am Floor Area 2,941 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F = = = = = = = = = = = = = = = = = = = = = =1.778. = = = = = = = = Conduction R-38 Roof R.38.2x14.16 R-21 Wall (W.21.2x6.16) Mand.atori-Minim.um Mandato Minimum Mandatory Minim..um Mandato Minimum -21 Wall (W.21.2x6.161 MandatoN Minimum andatory_Minimum Mandato Minimum AllandatO4-Minim,um Mandatory Minimum Mandatory Minimum Mandatory Minimum andatoryMinim.u. andato4-Minimum - 1-Wall_�K2.1.24A.6. M d�tQry Mi i 2-21 Wall W.21.2x6.16 andatoty_Minimu M. an.dato4Miaimum Mandatory Minimum Mandato Minimum Minimum and.atoN-Minimum Mandatory Minimum R-21 W (W.21.2x6.16) =2LWaU4W21-2x6a 6. _VVO andatockMinimum Mandatory Minimum Mandato"inim.u.. Mandatory Minimum Mandatory Minimum Mandatory Minimum Mandato Minimum Mandato[y Minimum Mandatory Minimum Mandatory Minimum U -Value ._n_ ...--"--- Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 25 849 Infiltration: 1.00 x 1.064 X 2 941 X 12.50 X 0.377 / 6 ] X 44 = 10 824 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 46,364 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 21 of 32 -71 2 662.0 X X x X X X x x x X X x X X X X x X X X X X X X X X X X X X X X X X X X X X X 0.0290 x X x X X X X X x X x x X X X x X x x x X X X X X X X x X X X X X X X X x X X 44 = = = = = = = = = = = = = = = = = = = = = =1.778. = = = = = = = = 3,397 316.7 0.0690 44 961 24.0 0.3700 44 391 55.2 0.3700 44 899 15.1 0.3700 44 246 38.9 0.3700 44 634 345.9 0.0690 44 1,050 61.7 0.3700 44 1,004 72.2 0,3700 44 1,176 19.8 0.3700 44 322 111.8 0.3700 .,820 493 30.3 0.3700 44 72.2 0.3700 44 1,176 1908 0.3700 44= 322 39.3 0.3700 44= 9.3 24.0 0.3700 44 391 26-0 24.0 0_0690 7-9 0.3700 44 391 714.6 0.0690 44 2,170 1.2 0.3700 44 19 1.2 0.3700 44 t9 1.2 0.3700 44 19 28.0 0.3700 44 456 58.5 0.3700 44= 2 55.2 0.3700 44= 899 246 15.1 0.3700 44 25.0 0.0690 44 76 585.8 0_0690 0_5.0.0.0 24 0_ 44= 528 3.5 .0 9 44 586 36.0 0.3700 4_4 586 6.8 0.3700 44 110 6.8 0.3700 44 110 29.8 0.3700 44 484 10.5 0.3700 44 171 36.0 0.3700 44 586 6.8 0.3700 110 36.0 0.3700 44 586 6.81 0.3700 44 Lt0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 25 849 Infiltration: 1.00 x 1.064 X 2 941 X 12.50 X 0.377 / 6 ] X 44 = 10 824 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 46,364 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 21 of 32 -71 ROOM HEATING PEAK LOADS Wt�ect Title .Date chell Residence 8/m/9nnf; Room Information Design Conditions Room Name Living Time of Peak Jan 12 am Floor Area 2,941 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F ' s' Conduction Area U -Value AT OF l Mandatory Minimum surface Area 36.0 x x x x x -X x x X x x X X x x X X x X X X x x x X X X x• X X X x X X x x X X X X 1 0.3700 X X x X x x x x X x x X X x x X X x. X x X x X x x x X X X X X x x x x x X X X x 44 = = = = = = t = = = = = = = = — _ = = 586 Mandato Minimum 6.8 0.3700 44 110 Mandato t-Minim.0 19.0 0.3700 44 309 Mandatoy Minimum 42.2 0.3700 44 688 Stab=On_Grade perimeter = 237.0 0.7300 44 7.612 Slab -On -Grade perimeter 12.0 0.7300 44 385 Items shown with an asterisk (') denote conduction through an interior Infiltration: 1 1.001 X 1.064 x Schedule Air Sensible Fraction to another room. 2 941 X 12.50 Ceiling Height 0.377 / 60] ACH Page Total: 44 &T 9 691 10,824J. TOTAL HOURLY HEAT LOSS FOR ROOM 46,364 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 22 of 32 l ROOM HEATING PEAK LOADS ro'ect Title Date itchell Residence .,in/qpm Room Information Design Conditions Room Name 2ns Floor & Studio Time of Peak Jan 12 am Floor Area 575 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF 44 Conduction Area 359.0 216.0 575.0 339.8 9.0 9.0 9.0 20.2 27.7 27.7 21.0 331.3 1.2 12 1.2 25.2 9.0 9.0 9.0 220.3 9.0 9.0 9.0 1.2 1.2 1.2 1.2 U -Value x x X x X X X x x x x x X x, X x X x X X X X x X x x X X x x X x X x x x x x x X AT of = = = = = = = = = = = = = = = = = = = = = = =147 = = = = = = = = = = = = Btu/hr 44 758 44 456 44 734 44 1,031 44 147 44 147 44 147 44 330 44 533 44 452 5 44 342 44 1,006 44 19 44 44 19 19 4_4 410 44 147 44 147 44 147 4_4 44 6.6.9 147 44 147 44 4-4 1.9 44 19 44 19 4 -4-4- Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 8 624 Infiltration: [ 1.001 x 1.064 X 575 X 9.00 x 0.524 / 60] x 44 = 2,116 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,740 EnergyPro 4.2 by EnergySoft User Number: 5862 'Job Number: Page: 23 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title Date itrhPll RPsiripnrp R/:An/g(if1R Room Information Desi n Conditions Room Name: Master Suite Sr Bedrooms Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,577 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F • 1�1 Opaque Surfaces R-38 Roof R.38.2x14.16 R-21 Wall (W.21.2x6.16) R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.24.16 R-21 Wall W.21.24.16 R-21 Wall (W.21.24.16) R-21 Wall (W.21.24.16) Orientation A.o!2 N 1,497.0 N 675.4 (E 284.2 SE 24.6 S 264.6 SW 55.6 (W) 224.8 (NW) '44.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Glazi U -Factor CLTD 1 Btu/hr x x x x x x X x x x x x 0.0201 X X X X X X X X x x x x 56.0 = = = = = = = = = _ _ 1,683 0.0690 23.0 1,072 0.0690 33.0 647 0.0690 31.0 53 0.0690 26.0 475 0.0690 31.0 119 0.0690 33.0 512 0.0690 30.2 92 19.6 9.0 19.6 N 0.0X 19.6+ 24.0X 19.6= N 0.0 -- 9.0 Page Total 4 652 Orientation Btu/hr Shaded Area x x x x X x X GLF + + + + + + + Unshaded Area x X x x x X X Page GLF = = = = = = _ = N 0.0 19.6 9.0 19.6 U 0.0 19.6 21.2 19.6 (N) 0.0 19.6 21.2 19.6 N 0.0 19.6 9.0 19.6 N 0.0X 19.6+ 24.0X 19.6= N 0.0 19.6 9.0 19.6 N 0.0 19.6 31.1 19.6 N 0.0x 19.6+ 25.0X 19.6- E 0.0x 19.6+ 72.2X 39. (E) O.Ox 19.6+ [:: 34.2x Total Btu/hr Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 E ui ment x Dwelling Units x 1,600] Watts/sgft = 1,6001 Infiltration: 1.064 x 1.24 x 99.92 X 40 = 5 276 Air Sensible CFM ELA ZST TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29 794 Latent Gain Btu/hr Occupants 0 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 = 57 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 857 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:24 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY W'O'ecttTitle Date itchell Residence �i/30/2006 Room Information Design Conditions; Room Name: Master Suite & Bedrooms Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,577 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F . Opaque Surfaces Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • Glazing Glazing Glazing Glazing Glazing Glazing Glazing .Glazing Glazing Glazing U -Factor CLTD 1 Btu/hr x x x x x x x x x x x x Btu/hr x x x x x x x x x x. x x x x x X X = = - = = = = = = _ = + + + + + Unshaded Area X X X X X Page GLF = = = = = U 0.0x 19.6+ 85.0x 39.2= U 0.0x 19.6+ 14.8X 39.2= E 0.0x 19.6+ 4.7X 39.2= SE 0.0x 19.6+ 14.8x 27.2= SE 0.0X 19.6+ 4.7X 27.2= S Page Total 0 ;Orientation Btu/hr Shaded Area x x x X X GLF + + + + + Unshaded Area X X X X X Page GLF = = = = = U 0.0x 19.6+ 85.0x 39.2= U 0.0x 19.6+ 14.8X 39.2= E 0.0x 19.6+ 4.7X 39.2= SE 0.0x 19.6+ 14.8x 27.2= SE 0.0X 19.6+ 4.7X 27.2= S 0.0 19.6 14.8 19.7 S 0.0 19.6 4.7 19.7 S 0.0 19.6 34.0 19.7 S 0.0 19.6 34.0 19.7 SW 0.0x 19.6+ 14.8x Total Btu/hr. - Internal Gain Btu/hr Occupants 4 X Occupants x 230 Btuh/oCC. = 920 E ui ment X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.24 X 99.92 x 40 = 5 276 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29 794 j Latent Gain Btu/hr Occupants � X Occupants x 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 = 57 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 857 Energy Pro 4.2 by EnergySoft User Number: 5862 Job Number: Page:25 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Wo,ect Title Date it -hell Residence 8/3()/gnnF Room Information Desicin Conditions Room Name: Master Suite & Bedrooms Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,577 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: _ 340F opaque 5urtaces Orientation Area U -Factor x x (SW) x x x X x X x x X x X x x x 4.7 x x = = = x x 19.6+ x x (� x x 72.2X x x Occupants F--41 x Occupants x 200 Btuh/occ. = x x 57 x x TOTAL HOURLY LATENT HEAT GAIN FOR ROOM x x x CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF ' Area GLF • Page Total Btu/hr 0 Btu/hr 127 518 2,835 3,480 Internal Gain (SW) 0.0 X x X x x X x X x 19.6 + + + + + + + + + 4.7 X x X X X X X X x 27.2 = = = (SWC 17.8X 19.6+ 6.2X 27.2= (� 0.0x 19.6+ 72.2X 39.2= Btu/hr Occupants F--41 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 = 57 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 857 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:26 of 32 Page Total Btu/hr 0 Btu/hr 127 518 2,835 3,480 Internal Gain Btu/hr Occupants 4 F1 X Occupants x 230 Btuh/occ. = 920 X Dwelling Units X 1'6001 Watts/sqft = 1 600 Infiltration: 1.064 X 1.24 x 99.92 X 40 = 5276 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29 794 Latent Gain Btu/hr Occupants F--41 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 = 57 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 857 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:26 of 32 E ui ment 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title Date , itrhPll RPsiriPnrP R/Rfl/9mr, Room Information Design Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces R-38 Roof (R.38.2x14.16) R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 R-21 Wall W.21.24.16 R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.16) Wood Door Orientation Area x X X X X X X X X X x X U -Factor X X X X X X x X X X X X CLTD 1 = = = = = = = = Btu/hr - N 2,662.0 0.0201 56.0 2,993 N 316.7 0.0690 23.0 503 E 345.9 0.0690 33.0 788 (SE) 26.0 0.0690 31.0 56 (S 714.6 0.0690 26.0 1,282 SW 25.0 0.0690 31.0 53 (W) 585.8 0.0690 33.0 1,334 (W) 24.0 0.5000 33.0 396 111.8 39.2 U 30.3 19.6 0.0 39. (E 0.0x 19.6+ 72.2X 39.2= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants B4 Equipment 1 Page I otal 17404 Orientation Shaded Area X X X x x X X GLF + + + + + + + Unshaded Area X X X X X x X Page GLF = = = = _ = N 0.0x 19.6+ 24.0x 19.6= N 0.0 19.6 55.2 19.6 N 0.0 19.6 15.1 19.6 N 0.0x 19.6+ 38.9x 19.6= (E) 0.0 19.6 61.7 39.2 (E 0.0x 19.6+ 72.2X 39.2= E 0.0 19.6 19.8 39.2 (E 0.0 19.6 111.8 39.2 U 30.3 19.6 0.0 39. (E 0.0x 19.6+ 72.2X 39.2= Total Btu/hr Btu/hr X Occupants X 230 Btuh/oCc. = 920 X Dwelling Units X 1,600] Watts/Sgft 1 1.6001 Infiltration: 1.064 x 1.24 x 186.34 x 40 = 9 840 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9941 Latent Gain Btu/hr occupants 1 4 Occupants X 2001 Btuh/oCc. = 800 Infiltration: 4 771 X 1.24 X 186.34 X 0.00010 = 106 • Air Latent CFM ELA ,nW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 27 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY oject Title Date L'litrhpll RPcirlPncP 8/m/9nnA Room Information Desi n Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration •Glazing Glazin Glazing Glazing Glazing Glazing Glazing CLTD 1 Page Total Orientation x x X x X X X X x X X X X x X X X X x X, X x x X x X X x x x X X x + + + - + + + + + Unshaded Area X x X X x X X x GLF E 0.0 19.6 19.8 39.2 UE 0.0 19.6 30.3 39.2 E 23.7X 19.6+ 0.3X 39.2 (SE) 0.0 19.6 24.0 27.2 S 1.2 19.6 0.0 19.7 U Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration •Glazing Glazin Glazing Glazing Glazing Glazing Glazing CLTD 1 Page Total Orientation .Shaded Area X x X X X X x X, X GLF + + + - + + + + + Unshaded Area X x X X x X X x GLF E 0.0 19.6 19.8 39.2 UE 0.0 19.6 30.3 39.2 E 23.7X 19.6+ 0.3X 39.2 (SE) 0.0 19.6 24.0 27.2 S 1.2 19.6 0.0 19.7 U 1.2 19.6 10.0 19.7 1.2 19.6 0.0 19.7 U 0.0 19.6 28.0 19.7 (S) 0.0x 19.6+ 58.5X 19. S 0.01 19.6+ 55.2x 19.7 Page Total Btu/hr Btu/hr 777 = 1,189 477 654 23 23 23 552 1,154 _ •1090 5 962 ' Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/occ. = 920 E ui ment 1 X Dwelling Units X 1,600] Watts/sgft = '1,60 + Infiltration: Cosa x tea x 186.34 x a = '9,8401 Air Sensible CFM ELA Z�,T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9 Latent Gain Btu/hr Occu ants 4 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 186.34 x 0.00010 = 106 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:28 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY ro�ect Title Date itchell Residence 8/30/2006 Room Information Desi - n Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 o Outdoor Daily Range: 340F • 0 ue 5urtaces Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants 4 E ui ment 1 U -Factor x x x x x GLF x x X Page x x (S) x x 15.1x x x 0.0x x x 39.2= x x 19.6+ x x W x x 0.0x x x 6.8X x CLTD 1 Page Total Orientation Shaded Area X GLF + Unshaded Area X Page GLF = (S) 0.0x 19.6+ 15.1x 19.7 (W 0.0x 19.6+ 36.0X 39.2= U 0.0x 19.6+ 36.0X 39.2= W 6.8x 19.6+ 0.0x 39.2= (W 6.8X 19.6+ 0.0x 39.2= (YJV 0.0x 19.6+ 29.8X 39.2= W 10.5X 19.6+ 0.0x 39.2= (YJV 0.0x 19.6+ 36.0X 39.2= W 6.8x 19.6+0.0x (W 0.0x 19.6+ 36.Ox Total Btu/hr 0 Btu/hr Btu/hr x Occupants X 230 Btuh/oCC. = 920 X Dwelling Units x 1,6001 Watts/sgft = 1.600 Infiltration: 1.064 X 1.24 X 186.34 X 9 840 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9 Latent Gain Btu/hr Occupants ® X Occupants x 200 Btuh/oCC. E800 Infiltration: 4 771 X 1.24 X 186.34 X 0.00010 = 106 • Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:29 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title Date it chell Residence 8/30/2006 Room Information Desi n Conditions Room Name: Living Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Page Total 0 Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr s (W ' 6.8X X X x x x x x X 19.6+ + + + + + + + + 0.0x X X x X x x X x 39.2= = = = - = 133 VM 0.0 19.6 36.0 39.2 1,413 W 6.8x 19.6+ 0.0x 39.2= 133 IM 0.0x 19.6+ 19.0x 39.2= 746 W 0.0 19.6 42.2 39.2 1,658 s E ui ment 1 Page Total a o81 Internal Gain Btu/hr Occupants 4 X Occupants x 230 Btuh/oCC. = 920 X Dwelling Units x 1,600] Watts/sgft = 1,60 Infiltration: 1.064 X 1.24 x 186.34 X = 9,8401 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53 994 Latent Gain Btu/hr Occupants x Occupants x 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.24 X 186.34 x 0.00010 = 106 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906 EnergyPro 4.2 by EnergySoft: User Number: 5862 Job Number: Page:30 of 32 E ui ment 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY 0 roject Title Date itrhPll RPciHPnra R/,Afl/gnnA Room Information Desicin Conditions X X X X X X X X X X X X Room Name: 2ns Floor & Studio Outdoor Dry Bulb Temperature: 1120F Floor Area: 575 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces R-19 Floor No Crawls ace R-19 Floor No Crawls ace R-38 Roof R.38.2x14.16 R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.16) R-21 Wall W.21.24.16 R-21 Wall (W.21.24.16) Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X x CLTD 1 = = = = = = = Btu/hr = = = = 359.0 0.0480 19.0 327 0.0 216.0 0.0480 19.0 197 (N 575.0 0.0201 56.0 646 (N 339.8 0.0690 23.0 539 E 175.5 0.0690 33.0 400 S 331.3 0.0690 26.0 594 (W) 220.3 0.0690 33.0 502 1.2 19.7 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • Glazing Glazin Glazing Glazing Glazing Glazina Orientation N N N N E E E S S S r-ayc 1 uiai I a,[uol Shaded Unshaded Area GLF Area GLF Btu/hr Occupants 4 E ui ment _ 1 0.0 X X x x x x X 19.6 + + + + + + + 9.0 X X X X X X X 19.6 = = = = 0.0 19.6 9.0 19.6 0.0 19.6 9.0 19.6 0.0x 19.6+ 20.2X 19.6= 0.0X 19.6+ 27.7X 39.2= 0.0x 19.6+ 27.7X 39.2= 0.0x 19.6+ 21.0X 39.2= 0.0 19.6 1.2 19.7 0.0 19.6 1.2 19. 0.0 19.6 1.2 19.7 Occupants 4 E ui ment _ 1 Page Total 3 998 Internal Gain Btu/hr , BX Occupants X 230 Btuh/occ. = 920 X Dwelling Units X 1,6001 Watts/Sgft = 1,6001 Infiltration: 1.064 X 1.24 X 36.43 x 40 = 1924 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 920 Latent Gain Btu/hr Occu ants F4 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 X 1.24 X 36.43 X 0.00010 = 21 Air Latent CFM ELA n w • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 821 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 31 of 32 Occupants 4 E ui ment _ 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY cTitle' Date ko'e itchell Residence 8/30/200.6 Room Information Desicin Conditions Room Name: 2ns Floor & Studio Outdoor Dry Bulb Temperature: 1120F Floor Area: 575 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72'FOutdoor Daily Range: 340F is ue surraces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration G rage I otal Btu/hr 0 Orientation x x x x x x x x x x x x X X X x x x x x x x x x x x x + + + = = = = = = = = = = = = X X X X GLF = = = Btu/hr (S 0.0 19.6 25.2 19.7 496 S 0.0x 19.6+ 9.0x 19.7= 178 (� 0.0 .19.6 9.0 19.7 178 S 0.0x 19.6+ 9.0x 19.7= 178 W 0.0X 19.6+ 9.0X 39.2= 353 0.0x 19.6+ 9.0x 39.2= 353 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration G rage I otal Btu/hr 0 Orientation Shaded Area X X X GLF + + + Unshaded Area X X X X GLF = = = Btu/hr (S 0.0 19.6 25.2 19.7 496 S 0.0x 19.6+ 9.0x 19.7= 178 (� 0.0 .19.6 9.0 19.7 178 S 0.0x 19.6+ 9.0x 19.7= 178 W 0.0X 19.6+ 9.0X 39.2= 353 0.0x 19.6+ 9.0x 39.2= 353 0.0x 19.6+ 9.0X 39.2= 353 W 0.0x 19.6+ 1.2X 39.2= 46 U 0.0x 19.6+ 1.2X 39.2 46 W 0.0x 19.6+ 39.2= 46 ---!I I Page Total 2 226 Internal Gain Btu/hr Occu ants 4 x Occupants X 230 Btuh/occ. = 920 E ui ment X Dwelling Units X 1,600] Watts/sgft = 1,600 Infiltration: 1.064 X 1.24 X 36.43 X ��40 = 1924 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 920 Latent Gain Btu/hr Occu ants ® X Occupants. x 200 Btuh/occ. = 800 Infiltration: 4 771 X 1.24 X 36.43 X 0.00010 = 21 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 821]. EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 32 of 32 r A r TITLE 24 REPORT Title 24 Report for: Mitchell Casita 52958 Via Dona La Quinta, CA 92253 ` 4 r Project Designer: < RAM Companies 1544 Eureka Rd #140 . Roseville, CA 95661 } , 916-789-1400 ` } Report Prepared By: t • Sheila Munson 'Eagle Quest Specialties, Inc. 42335 Washington Suite_ F #330 Palm Desert, CA 92211 M (760) 3454859 41 Job Number: 'Date: 8/30/2006 y he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the.Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: User Number: 5862 A ,� .r h .. - - y i ..- �i. s .. .. � J � � .. .a� + + Certificate Of Compliance : Residential ❑ Addition (Part 1 of 4) CF -1 R Altchetle as.ita ft2 Root_ Wood- 440_ 8/_3012QQ6 Title Project - -52-9 5-8-M Existing Floor Area: ' Date Project Address (E) 90 deg Raised Floor Area: Building Permit # �aq-e__Quest_S_peci.alties.,_I.nc. Doc mentation Author Fuel Type: (760) 345-4859 Telephone Plan Check/Date EneLgVEro Compi ce Method 440 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance Average Ceiling Height: _(kBtu/sf- r) Design Design Margin 184 ft2 Space Heating 2.49 2.35 0.14 Space Cooling 92.18 88.98 3.20 1 Fans 14.01 15.80 -1.79 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Area Totals 108.67 107.12 1.55 x._00_ Conditioned- -Setback- Percent better than Standard: -n/a 1.4% Building Type: MJ Single Family ❑ Addition Total Conditioned Floor Area: 440 ft2 Root_ Wood- 440_ ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: Wall- Wood_ 220_ Natural Gas Slab on Grade Area: 440 ft2 Fenestration: Wall- Wood- 37_ -0_0.69_ R-21 -R=0_0_--27.0_ Average Ceiling Height: 10.0 ft Area: 184 ft2 Avg. U: 0.37 Number of Dwelling Units: 1.00 Ratio: 41.9% Avg. SHGC: 0.30 Number of Stories: 1 UILDING ZONE INFORMATION # of Thermostat Vent one Name Floor Area Volume Units Zone Type Type Hgt. Area Casita 44.0 4,400 x._00_ Conditioned- -Setback- 2 -n/a OPAQUE SURFACES Insulation Act. New New Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Root_ Wood- 440_ _0_029_ -R3.8_ X0_0_ -0- 0_Wall_ Ne.w New Wall --63--0-069- -R-21 _E2_0_0_ 0_-90 Wall_ Wood_ x.83_ _0_0.6.9_ R-21 --R-0_0_--4.5_ 9.0 Wall- Wood- 24 -0-069---R--2-1---R--O-O--90--90 Wall- Wood_ 220_ _0_0.6.9- R-21 JRm0...0_---t3.5__9.0 Wall- Wood_ 18.5_ _0..06.9_ -R21 X0_0_ _2259.0 Wall- Wood- 37_ -0_0.69_ R-21 -R=0_0_--27.0_ 9.0 Wall_ Wood- 123_ _0.069_ -R21. _IR0.0_ -315.9.0 Gains Condition Y / N Status JA IV Reference Location / Comments New 02-A11 Casita New New _0.9=96 09- Casita Casita New Ne.w N.ew _0.9_A6 -09=A6- _0.916 Casita Casita Casita Ne.w New _0.9=96 _09- C.asita Casita I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:3 of 13 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Ah Itchell Casita 8/30/2006 roject Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments _'L 2 Win.dow--Right_(.N)_ 1227_ Window Right (N)_ 4.0 -0.3.7-0 _NERC _0.3.0 -NERC. 0.370 NFRC 0_30 NFRC 0_ 0 -9.0- N.ew Mandatory -Minimum 90 New Mandatory Minimum Casita Casita 3 Window Right U, 12.7 0.370 NFRC 0_30 NFRC 45 90 New Mandatory Minimum Casita 4 WindowRight U. 4.0 0.370 NFRC 0_30 NFRC 45 90 New Mandatory Minimum Casita 5 Window Front (E)_ 25.5 0.370 NFRC 0_30 NFRC 90 90 New Mandatory Minimum Casita 6 Window Left (SW) 21.2 0.370 NFRC 0_30 NFRC 225 90 New Mandatory Minimum Casita L Window Left (SW)37 -O-3B N F 3 C 0.30 NFRC 225 9QLlew Maa ato_ry Minimum Casita 8 Window Left U 12.7 0.370 NFRC 0.30 NFRC 225 90 New Mandatory Minimum Casita 5 10 Window Left (SW) 4.0 Windgw Rear (W)- 4.0 0_3Z0 NFRC J 30 NERC 225 9,37-0 NFRC -0- 30 NERC 270_ 90 Ll we Mand Minimum 90 New MarAdato_ryMinimum Casita Carta Window Rear (W)- 4.0 0.370 NFRC 0_30 NFRC 270 90 New Mandatory. Minimum Casita 12 Window Rear (W)- 12.7 0.370 NFRC 0_30 NFRC 270 90 New Mandatory Minimum Casita 13 14 Window_Rear(.W)- 12.7- Window Rear (NW) 12.7 -0-37-0 -NER.C_0_30 NFRC _270_ 0.370 NFRC 0_30 NFRC 315 90 New 90 New M.and.atopy-Minimum Mandatory Minimum Casita Casita 15 Window Rear CNW) 4.0 0.370 NFRC 0_30 NFRC 315 90 New Mandatory Minimum Casita 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Window Overhang I Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 JA IV Reference Bug Screen 0.76 Concrete, Heavyweight Bug Screen 0.76 8.5 3.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0.0 0.0 0 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Buq Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN r� EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:4 of 13 1 Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 150 4.00 28 0.98 0 26-A1 New Casita / Slab on Grade Concrete, Heavyweight 290 4.00 28 0.98 2 26-A1 New Casita / Slab on Grade Condition PERIMETER LOSSES Insulation Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 33 None No Insulation 26-A1 New Casita Slab Perimeter 69 None No Insulation 26-A1 New Casita r� EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:4 of 13 1 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Aft,lItchell Casita 8/30/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum, Condition Thermostat Location Type Eff Type Eff Status Type Casita Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location Casita Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 New Yes WATER HEATING SYSTEMS Rated l Tank Energy Standby! Tank Insul. .Water Heater # in Input Cap. Condition Factor Loss . R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Control # HP Hot Water Piping Length (ft) Add 1/2" In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: H ; M Garwe j -a t Name: Sheila Munson Title/Firm: RAM Companies Title/Firm: Eagle Quest Specialties, Inc. Address: 1544 Eureka Rd #140 Address: 42335 Washington Suite F #330 _ Roseville, CA 95661 Palm Desert, CA 92211 _ Telephone: 916-789-1400 Telephone: (760) 345-4859 Lic. #: 40 2140113 4 3 6% (signature) I t(dat6) (signature) (date) Enforcement Agency Name: Title/Firm: dress: lephone: (signature/stamp) 5of13 Certificate Of Compliance: Residential (Part4 of 4) CF-1R ',Mitchell Casita 8/30/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the ddequacy of the special justification and documentation submitted. Plan Field Multiple Dwelling Units are served by a common water heater. Verify DHW details on Part 3 of the CF -1 R. The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 150 sgft Exposed Slab Floor, 4.00" thick at Casita HIGH MASS Design - Verify Thermal Mass: 290 sgft Covered Slab Floor, 4.00" thick at Casita HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R pian Field installation certificate. �he HVAC System "Casita" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. =Cooling ystem "Casita" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. System "TRANE 4TTX4024/TUD60R936 (2)" includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. Run Initiation Time: 08/30/06 11:53:50 Run Code: 1156964030 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 13 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether y they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ • f§150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ 1 ❑ • § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. .. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ . b. outside air intake with damper and control, flue damper and control ❑ ❑ ,❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual El1:1El § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. + § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X El CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ • 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ • § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑„ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:7 of 13 C] • Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ .duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ - ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118. (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ x ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ Q ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:8 of 13 r.� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Id ROJECT NAME DATE Mitchell Casita 8/30/2006 SYSTEM NAME FLOOR AREA Casita 440 ENGINEERING CHECKS SYSTEM LOAD Number of Systet Heating System Output per Systen Total Output (Btut Output (Btuh/sqft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) I Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions IEATING SYSTEM PSYCHROMETRICS 1 47,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 47,000 106.8 CFM 24,000 24,000 2.0 TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 628 11,354 816 295 10,993 at Time of Coolinq 0 111.0/72.5°F 78.8/62.8°F 78.8/62.8°F 1,177 1,015 0 0 115 4,601 -106 115 5,239 0 Supply Fan Cooling Coil 0 11177 1,015 18.310 710 ovu 800 TRANE 4TTX4024rrUD60R936 (2) 20,394 300 1.82 400.0 14.4 Total Adjusted System Output 20,394 300 (Adjusted for Peak Design Conditions) 0.26 TIME OF SYSTEM PEAK F Aug 2 pm m TemDeratures at Ti 47,000 47,000 Jan 12 am 26.0 OF 62.7 OF 62.7 OF 105.0 °F O Supply Air Ducts Outside Air 115 cfm 103.8 OF Supply Fan Heating Coil 800 cfm ROOMS 68.8 OF 70.0 °F EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 13 Return Air Ducts S COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolinq Peak) 111.0/72.5°F 78.8/62.8°F 78.8/62.8°F 55.0/53.7°F Supply Air Ducts Outside Air 115 cfm Supply Fan Cooling Coil 56.4 / 54.3 of 800 cfm ROOMS 51.7% R.H. 72.0!60.5°F '3.4/61.0°F 24 Return Air Ducts I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 13 _ rr ROOM LOAD SUMMARY EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 13 i ROJECT NAME Mitchell Casita DATE 8/30/2006 SYSTEM NAME Casita FLOOR AREA 440 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casita 1 628 11,354 816 628 11,354 816 295 10,993 t ' PAGE TOTAL 1 6281 11,354 816 295 10,993 TOTAL 1 628 11,354 816 295 10,993 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 13 i t ROOM HEATING PEAK LOADS Wofect Title Date itrhPn casita is/m/9nnR Room Information Desi n Conditions Room Name Casita Time of Peak Jan 12 am Floor Area 440 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF X x x x x x x X X X X x X X x x X X X X x x X X x x X X X x x x x X X X X X X X Conduction U -Value -n- R-38 Roof R.38.2x14.16) surface Area 440.0 x x x x x x x x x x x X x X `x X x x X x X x X X' X x X X X x X X X x x x x x x X0.472 0.0290 X x x x x x x X X X X x X X x x X X X X x x X X x x X X X x x x x X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = 561 R-21 Wall (W.21.2x6.16) 63.3 0.0690 44 192 Mandatory-_M.inim.um 12.7 0.3700 44 206 Mandatoy Minimum 4.0 0.3700 44 65 V_1ia1L(W.21.2x6.J 183.3 0.0690 44 557 Mandatory Minimum 12.7 0.3700 44 206 an -da] Minim m 4.0 0.3700 44 65 R-21 Wall W.21.24.16 24.5 0.0690 44 74 andatoLy-Minimu 25.5 0.370 44 415 R-21 Wall .21.2x6.16 220.0 0.0690 44 668 - _LWalL(-W 21.2x6.16.) 184.6 0.0690 44 5.6.0 346 Mandato Minimum 21.2 0.3700 44 Mandato1y Minimum 37.5 0.3700 44 610 Mandato Minimum 12.7 0.3700 44 206 an.datoiy_Minim.um 4.0 0.3700 6.5 R21_W.a1L(_W_212x6A6.) 36.7 0.0690 44 111 andato*Minimum Q -0-3700 0.3700 44 65 i Um 4.0 44= 65 �Mandat4[y ulan a ory Minimum 12.7 0.3700 44 206 'Slab Allandatory-Minimum.12.7 0.3700 44 206 -2_LWall (W 21-2x6-16.) 2 44 3.7 Mandato Minimum 12.7 -0-00Q 0.3700 44 206 Mandato Minimum 4.0 0.3700 44 65 -On -Grade perimeter = 33.0 0.7300 44=1,060 Slab= -On perimeter = 69.0 0.7300 216 Items shown with an asterisk (•) denote conduction through an interior Infiltration: 1 1.00 x 1.064 x chedule AIr Sensible Fraction to another room. 440 x 10.00 Ceiling Height / 60] ACH Page Total: 44 &T 9 374 1 619 TOTAL HOURLY HEAT LOSS FOR ROOM 10,993 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 11 of 13 V RESIDENTIAL ROOM COOLING LOAD SUMMARY W oject Title Date itrhPll Casita R/.monnA Room Information Desicin Conditions U -Factor Room Name: Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 440 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F • Opaque Surfaces R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.16) R-21 Wall .21.24.16 R-21 Wall .21.24.16 R-21 Wall (W.21.24.16) R-21 Wall (W.21.24.16) Orientation Area X X X X X X x X X X X X U -Factor X X X X X X X X x X X X CLTD 1 440.0 0.0201 56.0 63.3 0:0690 23.0 183.3 0.0690 29.0 24.5 0.0690 33.0 220.0 0.0690 31.0 184.61 0.0690 31.0 36.7 0.0690 33.0 123.3 0.0690 30.2 (E 9.3X 18.5+ 16.2X 36.3 SSW) 0.0x 18.5+ 21.2X 25.4 (SW) 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Glazi Internal Gain Occupants 4 E ui ment 1 Nage i otal Orientation Shaded Area X 'X X X x x X X GLF + + + + + + + + Unshaded Area X X X X X X X GLF (� 0.0 18.5 12.7 18.5 N 0.0 18.5 4.0 18.5 (NE) 0.0 18.5 12.7 28.2 (NE) 0.0 18.5 4.0 28.2 (E 9.3X 18.5+ 16.2X 36.3 SSW) 0.0x 18.5+ 21.2X 25.4 (SW) 0.0 18.5 37.5 25.4 SW 0.0x 18.5+ 12.7X 25.4 SW 0.0 18.5 4.0 25.4 (_W) 0.0 18.5 4:-0 36.3 X Occupants X -2301 Btuh/oCC. = x Dwelling Units X 1,6001 Watts/sgft = Page Total Btu/hr 495 101 367 56 471 395 84 257 2 224 Btu/hr 235 74 357 113 = 761 541 954 322 102 145 3 603 Btu/hr 920 1 600 Infiltration: 1.064 X 1.24 X 27.88 X 1 1472 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11 354 Latent Gain Btu/hr Occupants ®x Occupants X 200 Btuh/oCC ` = 800 Infiltration: 4 771 X 1.24 x 27.88 x 0.00010 = 16 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 816 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 12 of 13 4- RESIDENTIAL ROOM COOLING LOAD SUMMARY 0 �ro�ectr,hTitle Date itPn i":acitn �R/,in/qnm Room Information Design Conditions X. x x x x x x x x x x X Room Name: Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 440 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD I Items shown with an asterisk(*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration •Glazing Glazing Glazing Glazin Glazing rage I oial Btu/hr 0 Orientation Btu/hr X. x x x x x x x x x x X X X x X X X X X x X x x x x x x x x x x x x + + + + + + + + + + = = = = = = = = = - = = X X X X X x X X X X Page GLF = = = = = = = = = = Btu/hr (� 0.0x 18.5+ 4.0x 36.3= 145 (W) 0.0 18.5 12.7 36.3 460 (M 0.0 18.5 12.7 36.3 460 (NW) 0.0 18.5 12.7 28.2 357 (NW) 0.0 18.5 4.0 28.2 113 Items shown with an asterisk(*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration •Glazing Glazing Glazing Glazin Glazing rage I oial Btu/hr 0 Orientation Btu/hr Shaded Area X X x X X X X X x X GLF + + + + + + + + + + Unshaded Area X X X X X x X X X X Page GLF = = = = = = = = = = Btu/hr (� 0.0x 18.5+ 4.0x 36.3= 145 (W) 0.0 18.5 12.7 36.3 460 (M 0.0 18.5 12.7 36.3 460 (NW) 0.0 18.5 12.7 28.2 357 (NW) 0.0 18.5 4.0 28.2 113 Total 1 535 Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/OCC. = P 920 Equipment 1 X Dwelling Units X 1,600] Watts/sqft = 1,6001 Infiltration: 1.064 X 1.24 X 27.88 X 1 1472 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,354 Latent Gain Btu/hr Occu ants 0 X Occupants X 200 Btuh/oCC. = 800 Infiltration: a 771 X 1.24 X 27.88 X 0.00010 = 16 • Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 816 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 13