06-4056 (SFD)P.O. BOX 1504 VOIC8.(760) 777-7012
.78-495 CALLE TAMPICO -7011
FAX, (760) 777
LA QUINTA, CALIFORNIA 92253 BUILDING& SAFETY- DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
ate: 4/23/07
Application Number
Owner
Property Address:
RODNEY A MITCHELL
APN: .772-410-999-1 1 :-298944-
1544 EUREKA RD #140
Application description: DWELLING - SINGLE' FAMILY DETACHED ROSEVI.LLE, CA 95661 APR 23 2007
Property Zoning:. �LOW DENSITY RESIDENTIAL
Application Valuatiom. 478060
Ci
F1 OF QUIN
NANc DEpr
Contracton'
�Applicant: Architect or Engineer: GRAYSTONE CONSTRCTION COMPANY
C 79405 HIGHWAY ill, SUITE 9-414
LA QUINTA, CA 92253
(760)238-0411
Lic No.. OOR SQUARE FOOT Lic. No. 863749
--------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with ].hereby affirm under penalty of perjury one of the following de . clarations:
Section 7000) of Division 3 of the' -Business and Professionals Code, and my License is in full force and effect. I have'and will maintain a certificate of consent to self -insure for workers' compensation, as provided'
,License Class*. B LicenselNo.:. 863749 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
Date I have and. will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION insurance carrier and policy number are: -
I herel�y affirm under penalty of perjury that I am exempt from.the Contractor's' State License Law for the Carrier STATE FLTND Policy Number 1828934-06
following reason Mac. 7031.5, Business and Professions Code: Any city or county that requires a permit. to I certify that, in the performance of the work for which this permit is issued, I shall not e —ploy any
construct, alter, improvei demolish, or repair any structure, prior.to its issuance, also requires the applicant for the person on laws of
in any manner so as to become subject to the workers' com�ensati California, -
permit to file a signed statement that he or she is licensed pursuant to the provisions ofthe Contractor's State. and agree that; if I should become subject to the workers' compensation provisions -of Section
License Law (Chapter 9 (commencing With Section 7000) of.Division 3 of the Business and Professions Code) or 3700 of the Labor Co:d�e',l Zf thwilh c��y with those visions.
that he or she isexempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by PV
-any applicant for a -permit subjects the applicant to a civil penalty of not more t . han five hundred dollars ($500) Date: pplic.nt:
1. as owner of the property, or my employees with wages.as their sole compensation, will do the work,:a:nd
the structure is not intended or offered ' for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECUREWORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJE6TAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and -who does the ' work himself or her�elf through his or , her own employees, provided that the DOLLARS 1$ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of -sale.). APPLICANT ACKNOWLEDGEMENT
I; as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director.of Building.and Safety for a permit subject to the
7044, Business. and Professions Code; The Contractors' State License Law does not apply. to an ov�ner of conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with.a c'ontractor(s) licensed 1 Each person upon Whose behalf this'application is made, each person at whose . request and for
pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a, result of this application,
I am exempt under Sec.
B.&P.C. for this reason the owner, and the ipplicant,'each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents.and employees for any act br omission related to the work being
performed under or following issuance of this permit.
Date: Owner: 2. Any permit issued as a reslult of this application becomes null and void if work is not commenced
within 180 days from.date of issuance of such permit, or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY permit to cancellation.
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that . I have read this application and state,that the . above information is'correct. I agree to comply with all
work for which this permit is issued (Sec. 3097, Civ. C.). ..cii y and county . ordinances and state lawsrelating to building construction, and hereby authori
ze repre ritatives
Lender.'s Name: of th!'s co ty to enter upon the above-mentioned pro e t f cition purposes
let '?SigRaturbi(Applicant or. Agent):
Lender's Address:
LQPERMIT
ce
Application Number
. . . . 06-00004 1 056
Permit
BUILD ING PERMIT -
Additional desc
Permit Fee
1962.50
Plan Check*Fee' .
1275.63
Valuation . . . .
Expiratioh-Date 1
10/17/07
Qty Unit Charge
Pg r
Extension
BASE
FEE
378 . 00
--------------------
BLDG
-----------
100,001-500,000
--------- --------------------
.639.50
1323.60
Permit . . . . ...
ELEC-NEW RESIDENTIAL'-,.
.Additional desc
Permit Fee
239.74
Plan Check Fee
59.94;,
Issue Date
Valuation...
0
Expiration Date
1
10/17/07�
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
5533.00 .0350
ELEC
NEW RES 1 OR 2 FAMILY
193.66
804'00 .0200
ELEC
GARAGE OR NON-RESIDENTIAL
16.08
1.00 15.0000
- - - - - - - - - - - --- - - - - - 7
EA 'ELEC*
- - - - - - - - - - -
TEMPORARY POWER POLE
- - --- - - - - - - - - - - -
------------------
15.00
7-7 -------
Permit GRADING PERMIT'
-
Additional desc'.'
Permit. -Fee-
15.-00
Plan Check Fee
1 .00,
Issue Date
Valuation
0
Expiration Date
10/17/07
Qty Unit..Charge
Per.
Extension
---------------------------------------------------------------------------------
BASE
FEE
15.00
Permit MECHANICAL'
Additional desc
Permit Fee . . .
..150*.50
Plan Check Fee
.37.63
Issue Date
Valuation
u
0
Expiration Date.
lb/17/07
Qty' Unit.Charge
Per
Extension
BASE
FEE
15.00
5.00 9-.0000
EA MECH
FURNACE <=100K
45-.00
�.00- 9.0000
EA MECH
B/C <=3HP/100K BTU
:6 . 00 6.5000
EA MECH.
VENT FAN
.45.00
39.00.
1.00 6.5000
- - - - - - - - - - - --- - - - - - - - - - - - -
EA MECH
-- - - --- --- - - - -
EXHAUST I400D
--- - - - - - - --- -- - - - - - 7 - - - - - - - - -- -
6 -.-5'0
- - - - - - -
LQPERMIT
Ile
Application Number . . . . . 06-00604056
Permit PLUMBING
Additional desc
Permit Fee 255.00 Plan Check Fee
63.75
Issue -Date Valuatio n
0
Expiration bate 1,0/17/07
Qty -Unit Charge Per
Extension,
BASE FEE
15.00
6.0000 EA PLB'F'IXTURE
168 -.00
i.00 15.0000. EA PLB BUILDING SEWER -
1.0b EA -PLB, ROOF DRAIN
6.00
2.00 7.5000 EA PLB.WATER-HEATER/VENT
15.06
EA PLB WATEk-'INST/ALT/REP
3,.00.
.1.00
1.00 9.0000 EA LAWN SPRINKLER SYSTEM
g.bo
12.00 ..7500. EA PLB GAS.'PIPE >=5
9.00
1.0.0 15.0060 -EA PLB.GAS METER'
-- - - - - - - - - - - - - - - - - - - - - - - -
15.00
- - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - -
Spe - cial Notes and Comments
- - - - --- - - - - -
55.3.3 sq. ft..sfd this permit does not'
include pool &-s a block walls or
driveway approacE.Dec-emb" i9,- 2006
11:59:27 AM ..jjohn6on
-------------------------------- 7 ------------------------------------------
Other Fees", . ... . . . . . . . ART IN -PUBLIC PLACES -RES.
695.00
DIF COMMUNITY CENTERS -RES'
14.00
DIF.CIVIQ CENTER -RES
995.00
ENERGY REVIEW FEE
127.56
DIF FIRE PROTECTION -RES'
14b.00
GRADING PLAN CHECK FEE
22.'80
DIF LIBRARIES'- RES
.355'. 00
DIF PARK.MAINT FAC'_� RES
22.00
DIFPARKS/REC - RES
892.00 -
STRONG MOTION (SMI) RES
47.80
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION
1930.00
'Fee -summary .'Paid Credited.
C-harg6d.
----------------
Due
7 ---------- ---------- -------- -7 -
Permit Fee Total' �2622.74'. .00. .00
- - - ---
2622.74
Plan Ch6ck Total. 1436.95. '750-. 0.0 .00
'686.§5
Other Fee Total. 5367.86'. .06 .00
5367.,86'
Grand Total* 9427.55 750.00 AO
'8677.55
LQPERMIT
MC GEE S UR VE FING, INC.
79-301 Country Club Dr.; Ste. 102 — Bermuda Dunes, CA 92201
Phone (760) 345-3828 — Fix (760) 772-5705
May 10, 2007
City of La Quinta
78,495 Calle Tampico
La Quinta, CA 92253
'00
Re: Pad Certification -3367
Pursuant to your request a field survey was conducted on the above referenced project to
determine the vertical location of the building pad. The above mentioned was found a's
follows:.,
LOT ADDRESS PAD (DES) PAD (FIELD)
11 52-958 Via Dona 1006.0! 1006.0'.
Sincerely
Wa
yne McGee HOS
L.S. 5479
Al%f- A.
LS 5479
F C
It
RO. BOX 1504 APPLICATION ONLY
Building 78-495 CALLE TAMPICO
Address 5Z9Si? WAPON4 LA QUINTA, CALIFORNIA 92253
Owner A19 Y IVI I 7_e#!!5 L e
Mailing
Address eiky-
� Q AP& Tel.
�4?Se V14- I -E J 9110 7,07/9
MOJ41
Contractor 1�17AA�h(r.712AIA:_ r
ress
J� Zip Te 1�.
State Lic �City
& Classif. Lic. #
Arch., Engr.,
D e s i g n e r I\j f 47:2
Address Tel.
City Zip State
Lic. #6— 2.16
LICENSED CONTRACTOR'S DEC RATIO
,f Chr
I hereby affirm that j_aa*�e un 0arovisions c nj r, licmm:�cing with Section
7000) of Divi the Busine ens is in full forcy and
effect.
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is lice=rsuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars (S500).
0 1, as owner of the property, or my employees with wages as their sole compensation, will do
the wo rk, and the structure is not intended or offered lor sale. (Sec. 7044, Business and Profes-
sionis Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
0 1, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law)
0 1 am exempt under Sec. - B. & PC. for this reason
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. - Company
0 Copy is filed with the city. 0 Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in.the performa w,�rLkforg which this permit is issued, I shall not
employ any person in any manni to eco bject to Work ation Laws of
Calif ' ;;�� :�,
D 1�ner
N ICE TO AlOPLICANT.- If, after_mR'ng this Certificate of Exem'ption you should become
subject to the Workers' Compensation provisions of the Labor code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is sus pended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize re P7 sentatives of this city to enter the above-mentioned
property for inspection purposes. I I A
Signature of applicant lz V .1 of V
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONST— OCC. GRP
A.R Number -7-77 —4/-0
Legal Description
Kojecit Descriptibn 4—
Sq. F No. No. Dw.
Size it �-.3?2 Stories Units
Newx Add 0 Alter 0 Repair 0 Demolition 0
0
Estimated Valuation
PERMIT MOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
91
TOTAL if
REMARKS CW
ZONE: BY..
Minimum Setback Distances:
Front Setback from Center Line
--Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:—
Validated by:
I Validation:
YELLOW = APPLICANT
Date- Permit
PINK = FINANCE
Coachella Valley -Unified Sthool District This Box'For District'Use Only
'83-733 Avenue 55, Thermal, CA 92274 DEVEWPER FEES PAM
.(760) 398-5909 — Fax (760) 398-1224.
AREA:
A40UNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
'DATE:
RECEIM
CHECK #:
INITIAL&
CERTIFICATE OF COMPLIANCE
(California Educali6n Code 17620)
Project Name: Residence is at tl Date: April 23, 2007
Owner'sName: _R6dneyMitchell Phone No.
Project Address:. - 52-958 Via Dona La Quinta, CA
Project Description: I SFD
APN 777-4 10-0 11-4 Trac t Lot #'s:
Type of Development. Residential XX Commercial
Total Square Feet of Building Area: 5,533 sq. ft.
ertification of Applicant/Owners: The person sigmng certifies that the above information is correct and make's this statement under
penalty of perjury and further'represents that he/she. is'authorized to sign on behalf of the ownek/developer,
Dated: April 23,'2007 Sig hatur e:
-SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
'ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 6.5995 - Approval PrioF to 1/1/87
Note -
Number of Sq.Ft. 5,�33.
Amount per Sq.Ft. $3.91
Amount Collected $2'1,634.03
Building Permit Application Completed: Yes/N6
By:, Carey M. Carlson, Asst. Supi., Business Services
%
Certificate issued by: Elvira Mattson, Office 'Technician, Signature -
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES,
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a Written I notice to the
project appellant,, at the time of 'payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest -the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to �uch Fees or the validity thereof, �ommences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whol e or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days.start ' s on the'date hereof. This Certificate * of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, asdetermined by the School District, and up,
to three (3) such extensions may be granted. At such time as this Certificate ex ' pires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to.obtain this.Certificate of Compliance.
MV:c/nivdocs/de�,fe�s/certificate of compliance fOl'hl Updated 33-2007 3/9/07
Certificate of Occupancy
BVilding & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance ' this structure was in compliance with the
provisions of the Building Code and the various ordinances of the Cit regulatin building
y 9
construction andlor use.
BUILDING ADDRESS: 52-958 VIA DONA
Use classification: SINGLE FAMILY DWELLING
Occupancy Group: R-3
Owner of Building: RODNEY A MITCHELL
Building Official
Type of Construction: VN
Building Permit No.: 06-4056
Land Use Zone:,RL
Addtess:'1544 EUREKA RD #140
POST IN A CONSPICUOUS PLACE
City, ST, ZIP: ROSEVILLE, CA 95661
By: A.J. ORTEGA
Date: MARCH 5,2008
TITLE 24 REPORT
Title 24 Report for:
Mitchell Residence
52958 Via Dona
La Quinta, CA 92253
Project Designer:
RAM Companies
1544 Eureka Rd #140
Roseville, CA 95661
916-789-1400
Report Prepared By:
Sheila Munson
Eagle Quest Specialties, Inc.
42335 Washington Suite F #330
Palm Desert, CA 92211
(760) 345-4859
CITY OF LA QUINTA
ILDING 8, SAFEV DEPT.
BU
APPROVED
TIUCTION
FOR cONS
Job Number:
DAT
Date: NO V
8/30/2006 Z,200&
'he EnergyPro computer program has been used to perform the calculations summarized in this comp ia ce report. This progr -has approval and is
by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy fficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by Energysoft Job Number: User Number: 5862
e� r
.
*
.,
r
F
• � N!. f'
Certificate Of Compliance : Residential (Part 1 of 4) . CF:1 R
-AWitrbe1LRe.sid.en.c
Insulation Act.
New-
A/ gnn(3
-Wrofect Title
-52-9 5-83fiaJD on-a-La-0winta
Area:' 1,869 ft2
Avg. U:
Date
Project Address
-Wall - -6Z5
Ratio: 36.7%
Building Permit #
i-e-st-Spe-cialties,lac
Docn'm;en tion Author
Number of Stories:
(760) 345-4859
Telephone
lUILDING ZONE INFORMATION
Plan Check/Date
-EnejnvPro
Compligtice Method
# of
15
Climate Zone
one Name
Field Check/Date
Volume
TDV Standard
Proposed
Compliance
1 S7
(kBtu rsf-yr) Design
Design
Margin
Raof-- Wood- 2 6 2-
Space Heating 2.85
1.75
1.10
-LLvjng.S.tat-
Space Cooling 62.68
62.90
-0.21
-0JJ- -C-onditimed- -Setback-
Fans 9.47
10.14
-0.67
Wall Wood- ----215-
Domestic Hot Water 5.04
4.59
0.45
-0.069- R-91 -R--GA---225--90
Pumps 0.00
0.00
0.00
Totals 80.05
79.38
0.67
F-looL- Wood- -359-
Building Type: [X-] Single Family
El Multi Family
Building Front Orientation:
FuelType:
El Addition
El Existing + Add/Alt
(W) 270 deg
Natural Gas
Total Conditioned Floor Area:
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Fenestration:
Insulation Act.
New-
Average Ceiling Height:
U -Fac. Cay. Cont. Azm.
Area:' 1,869 ft2
Avg. U:
0.37
Number of Dwelling Units:
-Wall - -6Z5
Ratio: 36.7%
Avg. SHGC:
0.33
Number of Stories:
-'90
lUILDING ZONE INFORMATION
-0-069- --R--21- -ELO-0- 135-90
-O.q-AR
# of
Thermostat
one Name
Floor Area
Volume
Units Zone Type
Type
Master-S-14te & edrooms
1 S7
-1-7_347
-O-3J- leeping
-SleepingStat-
Raof-- Wood- 2 6 2-
-----2-9AI
-36,Z62
-0-58- Lmy�nq
-LLvjng.S.tat-
-2 jo
-57-5.
-517-5
-0JJ- -C-onditimed- -Setback-
OPAQUE SURFACES
Insulation Act.
New-
Type Frame Area
U -Fac. Cay. Cont. Azm.
Tilt
ROOL- Wood- ---1-497-
-0-029- -J�U8- -R--DA -0-
New-
New-
New-
New-
Ne.w-
-Wall - -6Z5
0-069 -R�-21 --R--0-0- -0--90
-
-Wall Wood- 8-4-
-0.069 -R--2J- --R=0-0- -9.0-
-'90
-Wall Wood- 25-
-0-069- --R--21- -ELO-0- 135-90
-O.q-AR
-Wall Wood- 265
-0.069- -R=a --R--O-O- -180-
-90
-Wall Wood- -56-
-0-069- -aM- --R-0-0- 225-90
-09--A6-
-Wall Wood- 295-
-0.069- ---R--2J- -R--O-O- 9Z0--9.0
28-A4
-Wall Wood- -44-
-0-069- --a-2-1- --R--O-O- -3-15--90
21 -A4
Raof-- Wood- 2 6 2-
-0-029- -R--38- --R--O-O- -0--0
91-A4
Wall- ZtQod- -3-17-
-0 069 -R-21 -R-0-0 -0
90
Wall Wood- -3-46-
-0-069- R-21 -R-0-0--90--90
- 6
-WAII Wood ----26-
-0-069- -R--21 -R-0-0- -135-90
-Q9--A6-
Wall Wood- ----215-
-0-069- R-21 -B-OA--180--90
-
-Wall Wo-od- ---25-
-0.069- R-91 -R--GA---225--90
-0-9--A6-
Wall Wood- 586
-0-069- R-21 --R--O-O---2ZO--9,0
-DooL-- Noiie- 24
-0 5.0.0- -None- -R--O-O- ----2ZO--9,0,
F-looL- Wood- -359-
-0-0-4.8- -aA9- -R--0-0- -0- 1 0
Eo.or Waod 21.6-
-0-0-48- --R--19- --R--O-O- -0- 180
RooL- Wood -575-
-0-029- -R--38- -ELO-0- -0--0
-Wall Wood- -3-40-
-0.069- -R--2-1- -ELO-0- -0--90
-Wall- Wood- -7-6-
-0-069- -RL2-1- -R-0 -0- -9.0--90
-Wall- Wood- -3.31
-0-0-69- R-91 -13--0-0- ---18-0--9-0,
Wood- -220-
-0.069- -R--2A --R--0-0- 27090
5,093 ft2
n/a ft2
575 ft2
4,518 ft2
11.6 ft
1.00
Vent
Hgt. Area
n/a
-n/a
-n1a
Gains Condition
Y/N Status JA IV Reference Location / Comments
New- -02--AJJ-
-Master-&-Bedroomn
New-
-09--A6-
MasteL&-Bedroo
New-
New-
-Master-&-Red
Master -&-Bedrooms
New-
New-
New-
New-
Ne.w-
-Master-&-Redro-orns
Master-&-B-edrooms
-0.9--A6- Allaster-&-Bedro.oms
-0.9--A6- -MasteL&-Bed rooms
-0.2--Al-l- living
New-
-
1LvJng
New-
-O-q--A6-
Living
New-
-O.q-AR
- Living
New-
New-
-09--A6-
-09--A6-
Uving
ILving
New-
-09--A6-
-LMng
New-
28-A4
.1-Ning
New-
21 -A4
2nd-E]OOL&-Studin
New-
91-A4
2nd-Ooor-&-Studen
New-
-02-Al 1
2nd-FJGOL&-S.tudi
New-
- 6
2nd-Eloor-&-S.tud*10_
New-
-Q9--A6-
2nd-Ooor-&-S.tud i
New-
-
2nd-Eloor-&-Studi
N.e.w-
-0-9--A6-
2nd-S.o-or-&-Studi
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Paqe: 3 of 32 1
Certificate Of Compliance : Residential (Part 2 of 4) CF:1 R
ftitchell Residence 8/30/2006
'MPProject Title Date
FENESTRATION SURFACES
2 True Cond. Location/
# Type Area U -Factor' SHGC Azrn. Tilt Stat. Glazing Type Comments
-1- -ftndow-Left-(N)
2 Window Left
_UN _
-9-0
21.2
0-370 NERC -0-33 -NEPC
0.370 NFRQ 0.33 NFRQ
-0-
0
90 New-Maad atory-Minim um
90 New _Mandato�y Minimum
-MasteT-&B.e.dmoms-
Master & Bedrooms
3
Window
Left
_UN _
21.2
0.370 NFRQ 0.33 NFRQ
0
90 New
_Mandato[y. Minimum
Master & Bedrooms
4
Window
Left
(N)
9.0
0.370 NFRC 0.33 NFRC
0
90 New
_Mandato[y Minimum
Master& Bedrooms
5
Window
Left
-fNL
24.0
0.370 NFRQ 0.33 NFRQ
0
90 New
-Mandato Minimum
Master & Bedrooms
6
Window
Left
-UN
9.0
0.370 NFRQ 0.33 NFRQ
0
90 New
Minimum
Master & Bedrooms
7
Window
Left
(N)-
31.1
.-0-33 NFR-C
--U70 NFRC
0
-Mandato
90 New Ma -ad at Minimum
Kasle-r -& Bed rQoms--
8
Window
Left
(N)
25.0
0.370 NFRC 0.33 NFRC
0
90 New
_Mandato[y Minimum
Master& Bedrooms
-9-
Wind w
ReaL-(E)-
0.76
72.2
-0=1 NFRC -O-U NERQ
--9-0-
-K bhe3k-Manda
Minimum
Master & Be-d-rq-Qw-
J-0
Window
Rear
-(-E)-
34.2
0.37 NERC 0,33 NFRC
90
90 New Minimum
-Kast-eb&-Bedrooms-
11
Window
Rear
_(E)-
85.0
0.370 NFRQ 0.33 NFRQ
90
90 New
-Mandatory Minimum
Master & Bedrooms
12
Window
Rear
-LEJ-
14.8
0.370 NFRC 0.33 NFRQ
90
90 New
_Mandato[y. Minimum
Master & Bedrooms
A-3
14
-WjncLow--Rear-(E)-
Window Rear _(5Q
4 Z
14.8
-0-370 BE R -C 0-33 BERC
0.370 NFRQ 0.33 NFRQ
-90-
135
-90- Rew-Mandato.r�LlAinirnum-
90 New -Mandato[y Minimum
-mas.tef-&Bedworns-
Master & Bedrooms
15
Window
Rear
!jE
_L _)
4.7
0.370 NFRC 0.33 NFRC
135
90 New
_Mandatory Minimum
Master & Bedrooms
16
Window
Right
(S)
14.8
0.370 NFRQ 0.33 NFRC
180
90 New
MandatoN Minimum
Master& Bedrooms
17
Window
Ri ILt__(5j_
Condition
4.7
0.370 NFRC 0.33 -NERC.
180
90 New
Mandato!y Minimum
Master & Bedrooms
18
Window
Right (S)
34.0
0.370 NFRC 0.33 NFRQ
180
90 New
Mandato[y Minimum
Master & Bedrooms
19
Window--R-ig-ht-(5)-
--3A.-Q
-D-aLO NERC -Q.-U -RE-RC
180
90 New n Minim nn
Ma r & B rooms -
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from
NFRC or Table 116B.
Living / Slab on Grade
INTERIOR AND EXTERIOR SHADING
Window
Overhang-
Left Fin Right Fin
# Exterior Shade Type
SHGC Hgt. Wd.
Len. Hgt. LEA. REA.
Dist. Len. Hgt. Dist. Len. Hgt.
1 Bu Screen
0.76
y Bu Screen
0.76
3 Buq Screen
0.76
aBug Screen
0.76
u Bug Screen
0.76
6 Bug Screen
0.76
7- �uq Screen
0.76
8 Bug Screen
0.76
T Bug Screen
0.76
10 Bug Screen
0.76
11 Bug Screen
-i -2 'Bug
0.76
Screen
0.76
�-3 Bug Screen
0.76
T4 'Bu Screen
'Bug
0.76
T5 Screen
-076
1-6 Bug Screen
0.76
T7 _�jug_�creen
0.76
18 Bug Screen
0.76
T9 'Bug Screen
0.76 8.5 4.0
0.1
2.0 0 0.0 0.0 0
THERMAL MASS FOR HIGH MASS DESIGN
Area
Thick. Heat Inside
Condition
Location/
Type
(sf)
(in.) Cap. Cond. R -Val.
JA IV Reference
Status
Comments
Concrete, HeayMei-ght
457
4.00 28 0.98 0
26 -Al
New
Master & Bedrooms / Slab on Grade
Concrete, Heavyweight
1,12
4.00 28 0.98 - 2
26 -Al
New
Master & Bedrooms / Slab on Grade
Concrete-Ij �aeight
2,68
4.00 28 0.98 0
26 -Al
New
Living / Slab on Grade
Concrelg_Heavyweight
252
4.00 28 0.98 2
26 -Al
New
Living / Slab on Grade
PERIMETER LOSSES
Insulation
Condition
Location/
Type
Length
R -Val. Location
JA IV Reference
Status
Comments
Slab Perimeter
68
None No Insulation
26 -Al
New
Master & Bedrooms
Slab Perimeter
128
None No Insulation
26 -Al
New
Master & Bedrooms
Adftab Perimeter
237
None No Insulation
26 -Al
New
Living
12
None No Insulation
26 -Al
New
Living
Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 4 of 32
- -;I
�r
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
ell
Title
8/30/2006
Date
FENESTRATION SURFACES
# Type Area U -Factor' SHGC2
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
20.
21
W_tndow_Bight_(.S_W)
Window Right (SW)
14.8_
4.7
_0_37-0 _NERC _0..3.3 _NERC _225_
0.370 NFRC 0_33 NFRC
225
_90- New Mandato -Minimum
90 New Mandatory Minimum
_MasteL&-Bedroom. s
Master & Bedrooms
22
Window
Right (U
24.0
0.370 NFRC 0_33 NFRC
225
90 New
Mandatory Minimum
Master & Bedrooms
23
Window
Front (W)
72.2
0.370 NFRC 0_33 NFRC
270
90 New
Mandatory Minimum
Master & Bedrooms
24
Window
Left (N)
24.0
0.370 NFRC 0_33 NFRC
0
90 New
Mandatory Minimum
Livin
25
Window
Left (N)_
55.2
0.370 NFRC 0_33 NFRC
0
90 New
Mandatory Minimum
Living
Window
Left (W
15.1
X37_0 NFRC_ 0 NFRC_
901New M_arldatSZry_Minimum
Living
27
Window
Left (NN
38.9
0.370 NFRC 0.33 NFRC
0
90 New
Mandatory Minimum
Living
28
Window ReaL_(E)_
_61 Z
-D-37-0 NFRC 0 3 _NF_RC 90
90_ New Mandsnt4ly Minimum
Living
.29
Window
Rear (E)_
72.2
0.370 NFRC 0 3 NERC 90_
90 New Massial2ry, Minimum
Living
30
Window
Rear (E)
19.8
0.370 NFRC 0_33 NFRC
90
90 New
Mandatory Minimum
Living
31
Window
Rear (Ej
111.8
0.370 NFRC 0_33 NFRC
90
90 New
Mandatory. Minimum
Livin
32.
33
W_irdow_Rear(E)_
Window Rear (E)
-30-3
72.2
0 3Z0_NERC 0.33 _NF_RC _90_
0.370 NFRC 0_33 NFRC 90
_90 Ne -w M.andatoiy-Min.ir.um
90 New Mandatory Minimum
_Living
Livinq
34
Window
Rear (E)_
19.8
0.370 NFRC 0_33 NFRC
90
90 New
Mandatory Minimum
Living
35
Window
Rear (E)
30.3
0.370 NFRC 0_33 NFRC
90
90 New
Mandatory Minimum
Livinq
36
Window
Rear (E)
24.0
0.370 NFRC 0_33 .NERC.
90
90 New
Mandatory Minimum
Living
37
Window
Rear (SEZ
24.0
0.370 NFRC 0_33 NFRC
135
90 New
Mandatory Minimum
Living
38
Window Right (S)
1.2
0.370 NFRC 0_3 NFRC __1$0_
90 New
Mandatory Minimum
Living
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LExt.
RExt.
Dist. Len. Hgt.
Dist. Len. Hgt.
20
Bug Screen
0.76
Ti
Bug Screen
0.76
22
Bug Screen
0.76
8.0
3.0
4.0
0.1
4.0
4.0
3
Bug Screen
0.76
4
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
12.3
5.0
0.1 4.0 0
0.0 0.0 0
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
2.3
13.0
10.0
0.1
10.0
10.0
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
8.0
3.0
10.0
0.1
10.0
10.0
0.0 0.0 0
0.1 4.0 0
37
Bug Screen
0.76
38
Bug Screen
0.76
0.6
0.6
10.0
0.1
10.0
10.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Run Initiation Time: 08/30/06 11:41:50 Run Code: 1156963310
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:5 of 32
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
itchell Residence 8/30/2006
roject Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazin4 Type Comments
_39--l_bd.ow-- Right_(.S.)_
40 Window Right U_
1..2.
1.2
-0.370-NERC-0-3.3
0.370 NFRC 0_33 NFRC
1.8.0__9.0_New
180
Mandato.- inim.um
90 New Mandatory Minimum
_Living
Living
41
Window Right (S)_
28.0
0.370 NFRC 0_33 NFRC
180
90 New
Mandatory Minimum
Livin
42
Window Right i_
58.5
0.370 NFRC 0_33 NFRC
180
90 New
Mandatory Minimum
Living
43
Window Right (S�_
55.2
0.370 NFRC 0_33 NFRC
180
90 New
Mandatory Minimum
Living
44
Window Right P_
15.1
0.370 NFRC 0_33 NFRC
180
90 New
Mandatory Minimum
Living
46
�IVd4�[orlt-(W)_
Window Front (W)
36 Q
36.0
=0 NFRC 33 1C
0.370 NFRC 0_33 NFRC
270
�Q New Mand Minimum
90 New Mandatory MinimumLiving
Living
AZ
Win_d9w Front (W)_
6.8
-D_3-7-0 NFRC 0-D NERC
---2Z0_
90 New MAndatQrylyl.in.itnum
Living
Aa
Aq
Window Front (W)_
Window Front (W)_
6A
29.8
X310 NF C 0-35 NERC
0.370 NFRC 0_33 NFRC
270_
270
9Q New Mandatory Minimum
90 New Mandatory Minimum
Usti
Living
50
Window Front (W)_
10.5
0.370 NFRC 0_33 NFRC
270
90 New
Mandatory Minimum
Livin
51
52
-Windowr Er_ont_(W)_
Window Front (W)_
36_0
6.8
0 37.0 _NFRC _0_33 _N.ERC
0.370 NFRC 0_33 NFRC
_2.7_0_
270
_90- New
90 New
Mandator: JL inimum
Mandatory Minimum
_Living
Living
53
Window Front (W)_
36.0
0.370 NFRC 0_33 NFRC
270
90 New
Mandatory Minimum
Living
54
Window Front (_W)
6.8
0.370 NFRC 0_33 NFRC
270
90 New
Mandatory Minimum
Living
55
Window Front (W)_
36.0
0.370 NFRC 0_33 _NF2C.
270
90 New
Mandatory Minimum
Living
56
Window Front (W)_
6.8
0.370 NFRC 0_33 NFRC
270
90 New
MandatoryMinimum
Living
51
Window ront_(W)_
---19_0-
310 NFRC 035 NFRC
-0--9k
New ManS1�t4[y Minimum
Living
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LEA
REA
Dist.
Len.
Hgt.
Dist.
Len.
Hgt.
39
Bug Screen
0.76
0.6
0.6
10.0
0.1
10.0
10.0
40
Bug Screen
0.76
0.6
0.6
10.0
0.1
10.0
10.0
41
Bug Screen
0.76
Buq Screen
0.76
0
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
8.0
4.5
0.1
2.0
0
0.1
2.0
0
46
Bug Screen
0.76
8.0
4.5
0.1
2.0
0
0.1
2.0
0
47
Bug Screen
0.76
1.5
4.5
8.0
0.1
8.0
8.0
0.1
2.0
0
0.1
2.0
0
48
Bug Screen
0.76
1.5
4.5
8.0
0.1
8.0
8.0
0.1
2.0
0
0.1
2.0
0
49
Bug Screen
0.76
8.5
3.5
0.1
4.0
0
0.1
4.0
0
50
Bug Screen
0.76
1.5
7.0
10.0
0.1
10.0
10.0
0.1
4.0
0
0.1
4.0
0
51
Bug Screen
0.76
8.0
4.5
0.1
2.0
0
0.1
2.0
0
52
Bug Screen
0.76
1.5
4.5
8.0
0.1
8.0
8.0
0.1
2.0
0
0.1
2.0
0
53
Bug Screen
0.76
8.0
4.5
0.1
2.0
0
0.1
2.0
0
54
Bug Screen
0.76
1.5
4.5
8.0
0.1
8.0
8.0
0.1
2.0
0
0.1
2.0
0
55
Bug Screen
0.76
8.0
4.5
0.1
2.0
0
0.1
2.0
0
56
Bug Screen
0.76
1.5
4.5
8.0
0.1
8.0
8.0
0.1
2.0
0
0.1
2.0
0
57
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Type Le
Insulation
R -Val. Location
Condition
JA IV Reference Status
Location/
Comments
Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 32
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Aft Itchell Residence 8/30/2006
roject Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
_5.8.
Window_Eront_(.1N)_
42.2.
_0...370 _NERC 0_3.3 -NERC _2.7.0_
_90_ Never Maadato4-Nrum.um
living
59
Window
Left (L4)_
9.0
0.370 NFRC 0_33 NFRC
0
90 New Mandatory Minimum
2nd Floor & Studio
60
Window
Left (NJ-
9.0
0.370 NFRC 0_33 NFRC
0
90 New Mandatory Minimum
2nd Floor & Studio
61
Window
Left (N)
9.0
0.370 NFRC 0_33 NFRC
0
90 New Mandatory Minimum
2nd Floor & Studio
62
Window
Left (N)
20.2
0.370 NFRC 0_33 NFRC
0
90 New Mandatory Minimum
2nd Floor & Studio
63
Window
Rear (E)-
27.7
0.370 NFRC 0_33 NFRC
90
90 New Mandatory Minimum
2nd Floor & Studio
SZ4
Window
Rear (E)_
27.7
-03ZONE6_C 0.33 NFRC
90
94 New MADjdak9sy Minimum
2nd Floor & Studio
65
Window
Rear (E)
21.0
0.370 NFRC 0.33 NFRC
90
90 New Mandatory Minimum
2nd Floor & Studio
66
Window L1k_(.S)_
1.2
QL370 NERC 0-33 1� FRC
1$Q-
99 New Mandatory i i um
�d Floor &Studio
67-
Window Riaht_($)_
1.2
QUO NFRC 0U3 NFRC
180
9Q New Mandatory Minimum
2nd Floor & Studio
68
Window
Right (S)_
1.2
0.370 NFRC 0_33 NFRC
180
90 New Mandatory Minimum
2nd Floor & Studio
69
Window
Right (S)_
25.2
0.370 NFRC 0_33 NFRC
180
90 New Mandatory Minimum
2nd Floor & Studio
10
71
Wiadow--- Bight_(.S)_
Window Right ($)
9.0
9.0
0337-0 _NEB.0 -0.3.3 _NEB.0
0.370 NFRC 0_33 NFRC
1-80_
180
_90- New Maad.atoryJMin.imum
90 New Mandatory. Minimum
_2nd-aoor_& Studio
2nd Floor & Studio
72
Window
Right (S)_
9.0
0.370 NFRC 0_33 NFRC
180
90 New Mandatory Minimum
2nd Floor & Studio
73
Window
Front (W)_
9.0
0.370 NFRC 0_33 NFRC
270
90 New Mandatory Minimum
2nd Floor & Studio
74
Window
Front (W)
9.0
0.370 NFRC 0_33 _NERC.
270
90 New Mandatory Minimum
2nd Floor & Studio
75
Window
Front U_
9.0
0.370 NFRC 0_33 NFRC
270
90 New Mandatory Minimum
2nd Floor & Studio
]rz
Window FroOt_(W)
1.2
Q_3Z0 NFRC 36 NFRC
227
90- New Ua di3t9sy Minimum
?[Ld_F_lo-Qr_&-atudio
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt.
58
Bug Screen
0.76
59
Bug Screen
0.76
60
Bug Screen
0.76
W21
Bug Screen
0.76
Bug Screen
0.76
63
Bug Screen
0.76
64
Bug Screen
0.76
65
Bug Screen
0.76 4.5 4.7 0.1 4.0 0 0.0 0.0 0
66
Bug Screen
0.76
67
Bug Screen
0.76
68
Bug Screen
0.76
69
Bug Screen
0.76
70
Bug Screen
0.76
71
Bug Screen
0.76
72
Bug Screen
0.76
73
Bug Screen
0.76
74
Bug Screen
0.76
75
Bug Screen
0.76
76
Bun Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
r�
i�
Run Initiation Time: 08130106 11:41:50 Run Code: 1156963310
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:7 of 32
i
Certificate Of Compliance : Residential
(Part 2 of 4) CF -1 R
�Itchell Residence
oject Title
8/30/2006
Date
FENESTRATION SURFACES
# Type Area U -Factor' SHGCZ
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
17 Window---Eront_(.W)_ 1.2. _0..37 -0 -NERC _0_33 NFRC —2-Z0_
78 Window Front (W) 1.2 '0.370 NFRC 0_33 NFRC
_90_ Raw—Mandatory—Minimum
270 90 New Mandatory Minimum
2nd-So-or_&Studio
2nd Floor & Studio
79 Window Front (W 1.2 0.370 NFRC 0_33 NFRC
270 90 New
Mandatory Minimum
2nd Floor & Studio'
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING Window Overhang "Left Fin
# Exterior Shade Type - SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt.
77 Bug Screen 0.76
78 ,. Bug Screen 0.76
79 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
.Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments"
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Right Fin
Run Initiation Time: 08/30106 11:41:50 Run Code: 1156963310
EnergPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:8 of 32
Certificate Of Compliance :
Residential
(Part 3 of 4)
CF -1 R
PItchell Residence
'Project Title
Date
8/30/2006
HVAC SYSTEMS
Location
Heating ;
Type
Minimum
Eff
Cooling
Type
Minimum
Eff
Condition
Status
Thermostat
Type
Master Suite & Bedrooms
Central Furnace
80% AFUE
Split Air C66ditioner
13.0 SEER
New
Setback
Living
Central Furnace
80% AFUE
Split Air Conditioner
13.0 SEER
New
Setback
2nd Floor & Studio
Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status. Tested?
Master Suite & Bedrooms Ducted Ducted Attic 6.0 New Yes
Living Ducted Ducted Attic 6.0 New Yes
2nd Floor & Studio Ducted Ducted Attic 6.0 New Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length - Diameter Thick.
WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul.
Water Heater - # in Input Cap. Condition Factor Loss R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext.
A.O. SMITH GVR-50 Small Gas All Pipes Ins 1 40,000 50 • New 0.62 n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump
Control # HP Type
`Hot Water Piping Length U Add 1/2"
In Plenum Outside Buried ' Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. .
Designer or Owner (per Business & Professions Code)
Name: �;ke. G2neo i
Title/Firm: RAM Companies
Address: 1544 Eureka Rd #140
Roseville, CA 95661
Telephone: 916-789-1400
Lic. M G
2
(signature) (dat
Enforcement Agency
Name:
Title/Firm:
,dress:
lephone:
Documentation Author
Name: Sheila Munson
Title/Firm: Eagle Quest Specialties, Inc.
Address: 42335 Washington Suite F #330
Palm Desert, CA 92211
Telephone: _(760) 3454859
�3
(signatur ( ate)
(signature/stamp)
of 32
Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R
Title
8/30/2006
Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These Items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
adequacy of the special justification and documentation submitted. Plan
Field
The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
he HVAC System "Master Suite & Bedrooms" incorporates HERS verified Duct Leakage. Target leakage is calculated and
ocumented on the CF4R.
The HVAC System "Master Suite & Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas
HIGH MASS Design - Verify Thermal Mass: 457 sgft Exposed Slab Floor, 4.00" thick at Master Suite & Bedrooms
HIGH MASS Design -Verify Thermal Mass: 1120 sgft Covered Slab Floor, 4.00" thick at Master Suite & Bedrooms
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The HVAC System "Living" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design - Verify Thermal Mass: 2689 sgft Exposed Slab Floor, 4.00" thick at Living
HIGH MASS Design - Verify Thermal Mass: 252 sgft Covered Slab Floor, 4.00" thick at Living
The HVAC System "Living" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "Living" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve.
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The Cooling System 'TRANE 4TTX4060fTUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must
field verify the installation of the correct Condenser.
The HVAC System "2nd Floor & Studio" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on
the CF -4R.
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approves ncma proviaer using ,c;, approveu tesung anaior vermcauon metnoas ano must oe reporteo on the Lr -4K
installation certificate.
Plan
Field
he HVAC System "Master Suite & Bedrooms" incorporates HERS verified Duct Leakage. Target leakage is calculated and
ocumented on the CF4R.
The HVAC System "Master Suite & Bedrooms" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The Cooling System 'TRANE 4TTX4060/TUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must
field verify the installation of the correct Condenser.
The HVAC System "Living" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "Living" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve.
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The Cooling System 'TRANE 4TTX4060fTUD100R960 (5)" includes credit for a 10.5 EER Condenser. A certified HERS rater must
field verify the installation of the correct Condenser.
The HVAC System "2nd Floor & Studio" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on
the CF -4R.
The HVAC System "2nd Floor & Studio" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The Cooling System 'TRANE 4TTX4030/TUD60R936 " includes credit for a 11.5 EER Condenser. A certified HERS rater must field
verify the installation of the correct Condenser.
0
I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 10 of 32 I
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise • residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown' elsewhere in the documents or on this checklist only.
r
a
DESCRIPTION' Check or initial applicable boxes or check NA if not applicable and included with the
'
ENFORCE -
permit application documentation..
N/A
DESIGNER
MENT
Building Envelope Measures
f§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
0
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑ .
❑
❑
'§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
�§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
Q
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
b. outside air intake with damper and control, flue damper and control
❑ _.
❑
❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑X
❑
§ 150(1): Slab edge insulation -water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
; • ❑
permeance rate no greater than 2.0 perm/inch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
El
a
El
Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. i
❑
❑
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient infiltration
❑
0
❑
(SHGC), and certification.
+ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ ::
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC, equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
El -
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
,
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
0
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑X
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space. r
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page: 11 of 32
W
Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
• compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
•
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ x❑ ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑
x❑
❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑ ❑
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
reductions in the cross-sectional area of the ducts.
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
®
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑ x❑ ❑
luminaire has factory installed HID ballast.
4. Exhaust fan systems have back draft or automatic dampers.
❑
❑
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
❑
❑
dampers.
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR by dimmer OR
❑ x❑ ❑
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
❑
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ x❑ ❑
retardant and provides shielding from solar radiation that can cause degradation of the material.
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑ ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) `
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ x❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires: Up to 50% of the Wattage, as determined
❑ ❑x ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ x❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR by dimmer OR
❑ x❑ ❑
are controlled a switch are
controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ x❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ x❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.2 by Energysoft User Number: 5862 Job Number:
Page: 12 of 32
Residential Kitchen Lighting Worksheet • WS -5R
aitchell Residence 8/30/2006
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire-Type High Efficacy? Watts Quantity Watts Other Watts
(1) 5" Circling Yes X - No 15.0 x 21 = 315 or
35w Recessed Incandescent Yes, No X '35.0 x 4 = or '140
35w Recessed SPOT Incandescent Yes No X 35.0 x 5 = or 175'
Yes No x = or
Yes No x _ or
Yes No x or -
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x or
Yes No x = or
Yes No x- or
` Yes No x _ or
Yes No x = or
Yes No x = or,
Yes No= r
_ x or.
Yes No x = or; ..
Yes No x = or
Yes No x = or
Yes No x = or
t
.Total A:. 315 B: 315.
COMPLIES IF Az B YES[i] NOO
e i ,'• a •.
t
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 32
LHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
diROJECT NAME DATE
Mitchell Residence 8/30/2006
SYSTEM NAME FLOOR AREA
Master Suite & Bedrooms 1,577
Number of Systems
I
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
Heating System
Output per System
79,000
Total Output (Btuh)
79,000
Output (Btuhlsgft)
50.1
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
Total Output (Btuh/sgft)
36.8
Total Output (sgft/Ton)
326.3
Air bystem
CFM per System
Airflow (cfm)
Airflow (cfm/sgft)
Airflow (cfm/Ton)
Outside Air (%)
Outside Air (cfmisgft)
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRI
COIL COOLING PEAKCOIL
HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
1,647
29,794
857
759
28,275
0
2,705
2,252
0
0
115
4,615
-96
115
5,255
0
0
2,705
2,252
39,8191 76
e,vvv
2,000 TRANE 4TTX4060/TU D 1 0OR960 (5) 45,095 4,032
1.27
413.8
5 8 Total Adjusted System Output 45,095 4,032
(Adjusted for Peak Design Conditions)
0.07 TIME OF SYSTEM PEAK Aug 2 pm
T
26.0 of 66.5 of 66.5 of n 105.0 of
Outside Air
115 cfm
68.9 of
11.0 / 72.5 of
Outside Air
115 cfm
3/60.9 of
0,
Supply Fan Heating Coil
2000 cfm
75.4 / 61.6 of
O
k Return Air Ducts `S
Temperatures at Time of Coo
754/R17OF 1 Kirin/-i'iQOF
Supply Fan
2000 cfm
79,000
79,000
Jan 12 am
Supply Air Ducts
103.9 of
ROOMS
70.0 OF
Supply Air Ducts
Cooling Coil 56.3 / 54.4 of
51.6% R.H. ROOMS
72.0 ! 60.5 of
Return Air Ducts I
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:14 of 32
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
itROJECT NAME DATE
Mitchell Residence 8/30/2006
SYSTEM NAME FLOOR AREA
Living 2,941
lNumber of Systems 21
Heatina Svstem
Total Output (Btuh)
Output (Btuh/sgft)
Cooling System
Output per System
Total Output (Btuh)
Total Output (Tons)
Total Output (Btuh/sgft)
Total Output (sgft/Ton)
Air System
CFM per System
Airflow (cfm)
Airflow (cfm/sgft)
Airflow (cfm/Ton)
Outside Air (%)
Outside Air (cfm/sgft)
Note: values above given at ARI conditions
(EATING SYSTEM PSYCHROMETRI
79,000
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
158,000
53.7
Latent
58,000
116,000
9.7
26.0 of 67.9 of 67.9 of
Outside Air
115 cfm
69.1 of
3I TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
2,984
53,994
906
1,245
46,364
0
4,902
3,693
0
0
115
4,630
-83
115
5,279
0
0
4,902
3,693
68,428 824 59,028
L,vvv
4,000 TRANE 4TTX4060/TUD100R960 (5) 87,397 . 10,182 158,000
1.36
413.8
1.92 Total Adjusted System Output
10,182(Adjusted for Peak Design Conditions)g7397 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
105.0 of
Supply Fan Heating Coil
4000 cfm
of Heati
in Return Air Ducts 4
Supply Air Ducts
104.1 of
ROOMS
70.0 of
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/72.5OF 74.2/61.2OF 74.2/61.3OF 55.0/53.9OF
O Supply Air Ducts
Outside Air
115 cfm Supply Fan Cooling Coil 56.2 / 54.4 of
4000 cfm 51.4% R.H. ROOMS
73.2 / 60.8 of 72.0 / 60.4 of
h Return Air Ducts 4
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Paae:15 of 32 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
�ROJECT NAME DATE
Mitchell Residence 8/30/2006
SYSTEM NAME FLOOR AREA
2nd Floor &Studio 575
Number of Systems
I 11
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
Heating System
Output per System
52,000
Total Output (Btuh)
52,000
Output (Btuh/sgft)
90.4
Cooling System
Output per System
24,000
Total Output (Btuh)
24,000
Total Output (Tons)
2.0
Total Output (Btuh/sqft)
41.7
Total Output (sgft/Ton)
287.5
F— r Y. em
800
Airflow (cfm)
Sensible
800
Airflow (cfm/sgft)
I Sensible
1.39
Airflow (cfm/Ton)
1,264
400.0
Outside Air (%)
0
14.4
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
I CFM
I Sensible
769
13,920
82
1 288
10,740
0
1,264
855
0
0
115
4,589
105
115
5,262
0
0
1,264
855
21,036 715 17 713
TRANE 4TTX4030/rUD60R936
20,438
264
Total Adjusted System Output
(Adjusted for Peak Design Conditions)
20,438
264
52,000
52,000
Outside Air (cfm/sgft) 0.20 TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am
Note: values above given at ARI conditions
(EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak)
26.0 of 62.8 of 62.8 of 105.0 of
Outside Air 0
115 cfm
Supply Fan Heating Coil
800 cfm
69.0 of
K Return Air Ducts 4
Supply Air Ducts
104.0 of
ROOMS
70.0 of
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/72.5OF 78.9/62.8OF 78.9/62.8OF 55.0/53.7OF
t�
Supply Air Ducts
Outside Air
115 cfm Supply Fan Cooling Coil 56.5 / 54.3 of
800 cfm 51.7% R.H. ROOMS
73.5/61.00F 1 72.0/60.5 OF
k Return Air Ducts `i
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 16 of 32 1
ROOM LOAD SUMMARY
4RO1ECT NAME
Mitchell Residence
DATE
8/30/2006
SYSTEM NAME
Master Suite & Bedrooms
FLOOR AREA
1,577
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
ISENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Master & Bedrooms
Master Suite & Bedrooms
1
1,647
29,794
857
1,647
29,794
857
759
28,275
.
J
}
s
,
j
A. PAGE TOTAL 1 1,647 29,794 857 759 28,275
' TOTAL 1 1,647 29,794 857 759 28,275
EnergyPro By EnergySoft User Number: User Job Number: Page:17 of 32
ROOM LOAD SUMMARY
d�ROJECT NAME DATE
Mitchell Residence .8/30/2006
SYSTEM NAME FLOOR AREA
Living 2,941
4
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Living
Living
1
2,984
53,994
906
2,984
53,994
906
1,245
46,364
PAGE TOTAL 1 2,984 53,994 906 1,245 46,364
TOTAL 1 2,984 53,994 906 1,245 46,364
EnergyPro By EnergySoft User Number: User Job Number: Page:18 of 32
ROOM LOAD SUMMARY
9 ROJECT NAME
, Mitchell Residence
DATE
8/30/2006
SYSTEM NAME .
2nd Floor & Studio
FLOOR AREA
575
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
2nd Floor & Studio
2ns Floor & Studio
1
769
13,920
821
769
13,920
821
288
10,740
1
PAGE TOTAL 1 769 13,920 a21 288 10,740
TOTAL 1 769 13,920 821 288 10,740
EnergyPro By EnergySoft User Number: User Job Number: Page: 19 of 32
ROOM HEATING PEAK LOADS I
roject Title
Mitchell Residence
n/gnnR
Room Information Desi n Conditions
Room Name Master suite &
Time of Peak Jan 12 am
Floor Area Bedrip
Outdoor Dry Bulb Temperature 26 OF
Indoor Dry Bulb Temperature 70 OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Conduction
R-38 Roof R.38.2x14.16
R-21 Wall W.21.2x6.16
andatoiyMinimu ..
Mandatory Minimum
Mandatory -Minimum
Mandatory Minimum
Mand' ry Minimum
Mandatory Minimum
andatonjMinimum
Mandato Minimum
R--2J-Wall (W.21 -2x6 16
Mandatory Minimum
Mandato Minimum
Mandatocy Minimum
an.dato"inim.0
Mandato4-Mnimum
R-Z1-Wc-dl-(W-2-1-2x6-1-6)
�ilaQday
Minimum
andato Minimum
R - 2J -Wall (W.. 912x6 16)
andatory Minimum
Mandato Minimum
Mandatory Minimum
Mand story Mini'
- LV�LaIL(lL1L.2]-.2x6 _t6a
Mandatory Minimum
amdaSQryMau imu
Mandatory-Minimu
- Wall 212x6-.6.
andato"inimu ..
R-21 Wall .21.2x6.16
Slab=On=Grade
Slab -On -Grade
U -Value
Items shown with an asterisk (') denote conduction through an interiors . urface to another room. Page Total: 22 471
Infiltration: r 1.001 X 1.064 X 1 577 X 1"1.00 X 0.429 / 6] X 44 = 5 804
`schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28,275
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 20 or 32
1497.0
X
x
X
X
X
X
X
x
X
x
X
X
X
X
x
X
x
x
X
x
X
X
X
X
X
X
X
x
X
x
x
x
X
X
X
X
X
X
X
0.0290
X
X
X
X
X
X
X
X
X
X
X
x
X
X
x
x
x
x
X
x
x
X
x
x
X
X
x
x
X
x
x
X
X
X
x
x
X
X
X
44
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,910
675.4
0.0690
44
2,050
9.0
0.3700
44
147
21.2
0.3700
44
346
21.2
0.3700
44
346
9.0
0.3700
44
147
24.0
0.3700
44
391
9.0
0.3700
44
147
311
0.3700
44
506
25.0
0.3700
44
407
284.2
0.0690
44
1,176
72.2
0.3700
44
34.2
0.3700
44
556
85.0
0.3700
44=
1,384
14.8
0.3700
44
0
4.7
0.3700
76
2.4_6
14.8
0-0690
0.3700
4-4
44=240
5
4.7
0.3700
44
76
264.6
0.0690
44
803
4
0,3700
4
0
4.7
0.3700
44
76
34.0
0.3700
44
554
34.0
0.3700
44=554
55.6
0.0690
169
14.8
0.3700
44
240
4.7
0.3700
44
76
24.0
0...3ZQ0
39J
68
4.8-
_0.69.0
44
72.2
0.3700.
J;
44.0
0.0690
44
1-3.4
2184
perimeter = 68.0
0.7300
44
perimeter = 128.0
0.7300
44
4,111
Items shown with an asterisk (') denote conduction through an interiors . urface to another room. Page Total: 22 471
Infiltration: r 1.001 X 1.064 X 1 577 X 1"1.00 X 0.429 / 6] X 44 = 5 804
`schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28,275
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 20 or 32
ROOM HEATING PEAK LOADS
roject Title Date
itrhPll ResifiPnrp R/. SMF
Room information Desicin Conditions
Room Name Living
Time of Peak Jan 12 am
Floor Area 2,941
Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70°F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=1.778.
=
=
=
=
=
=
=
=
Conduction
R-38 Roof R.38.2x14.16
R-21 Wall (W.21.2x6.16)
Mand.atori-Minim.um
Mandato Minimum
Mandatory Minim..um
Mandato Minimum
-21 Wall (W.21.2x6.161
MandatoN Minimum
andatory_Minimum
Mandato Minimum
AllandatO4-Minim,um
Mandatory Minimum
Mandatory Minimum
Mandatory Minimum
andatoryMinim.u.
andato4-Minimum
- 1-Wall_�K2.1.24A.6.
M d�tQry Mi i
2-21 Wall W.21.2x6.16
andatoty_Minimu
M. an.dato4Miaimum
Mandatory Minimum
Mandato Minimum
Minimum
and.atoN-Minimum
Mandatory Minimum
R-21 W (W.21.2x6.16)
=2LWaU4W21-2x6a 6.
_VVO
andatockMinimum
Mandatory Minimum
Mandato"inim.u..
Mandatory Minimum
Mandatory Minimum
Mandatory Minimum
Mandato Minimum
Mandato[y Minimum
Mandatory Minimum
Mandatory Minimum
U -Value
._n_ ...--"---
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 25 849
Infiltration: 1.00 x 1.064 X 2 941 X 12.50 X 0.377 / 6 ] X 44 = 10 824
chedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 46,364
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 21 of 32 -71
2 662.0
X
X
x
X
X
X
x
x
x
X
X
x
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0290
x
X
x
X
X
X
X
X
x
X
x
x
X
X
X
x
X
x
x
x
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
x
X
X
44
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=1.778.
=
=
=
=
=
=
=
=
3,397
316.7
0.0690
44
961
24.0
0.3700
44
391
55.2
0.3700
44
899
15.1
0.3700
44
246
38.9
0.3700
44
634
345.9
0.0690
44
1,050
61.7
0.3700
44
1,004
72.2
0,3700
44
1,176
19.8
0.3700
44
322
111.8
0.3700
.,820
493
30.3
0.3700
44
72.2
0.3700
44
1,176
1908
0.3700
44=
322
39.3
0.3700
44=
9.3
24.0
0.3700
44
391
26-0
24.0
0_0690
7-9
0.3700
44
391
714.6
0.0690
44
2,170
1.2
0.3700
44
19
1.2
0.3700
44
t9
1.2
0.3700
44
19
28.0
0.3700
44
456
58.5
0.3700
44=
2
55.2
0.3700
44=
899
246
15.1
0.3700
44
25.0
0.0690
44
76
585.8
0_0690
0_5.0.0.0
24 0_
44=
528
3.5 .0
9
44
586
36.0
0.3700
4_4
586
6.8
0.3700
44
110
6.8
0.3700
44
110
29.8
0.3700
44
484
10.5
0.3700
44
171
36.0
0.3700
44
586
6.8
0.3700
110
36.0
0.3700
44
586
6.81
0.3700
44
Lt0
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 25 849
Infiltration: 1.00 x 1.064 X 2 941 X 12.50 X 0.377 / 6 ] X 44 = 10 824
chedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 46,364
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 21 of 32 -71
ROOM HEATING PEAK LOADS
Wt�ect Title .Date
chell Residence 8/m/9nnf;
Room Information Design Conditions
Room Name Living
Time of Peak Jan 12 am
Floor Area 2,941
Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70°F
'
s'
Conduction Area U -Value
AT OF
l
Mandatory Minimum
surface
Area
36.0
x
x
x
x
x
-X
x
x
X
x
x
X
X
x
x
X
X
x
X
X
X
x
x
x
X
X
X
x•
X
X
X
x
X
X
x
x
X
X
X
X 1
0.3700
X
X
x
X
x
x
x
x
X
x
x
X
X
x
x
X
X
x.
X
x
X
x
X
x
x
x
X
X
X
X
X
x
x
x
x
x
X
X
X
x
44
=
=
=
=
=
=
t
=
=
=
=
=
=
=
=
—
_
=
=
586
Mandato Minimum
6.8
0.3700
44
110
Mandato t-Minim.0
19.0
0.3700
44
309
Mandatoy Minimum
42.2
0.3700
44
688
Stab=On_Grade
perimeter = 237.0
0.7300
44
7.612
Slab -On -Grade
perimeter 12.0
0.7300
44
385
Items shown with an asterisk (') denote conduction through an interior
Infiltration: 1 1.001 X 1.064 x
Schedule Air Sensible
Fraction
to another room.
2 941 X 12.50
Ceiling Height
0.377 / 60]
ACH
Page Total:
44
&T
9 691
10,824J.
TOTAL HOURLY HEAT LOSS FOR ROOM 46,364
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 22 of 32
l
ROOM HEATING PEAK LOADS
ro'ect Title Date
itchell Residence .,in/qpm
Room Information Design Conditions
Room Name 2ns Floor & Studio
Time of Peak Jan 12 am
Floor Area 575
Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
44
Conduction
Area
359.0
216.0
575.0
339.8
9.0
9.0
9.0
20.2
27.7
27.7
21.0
331.3
1.2
12
1.2
25.2
9.0
9.0
9.0
220.3
9.0
9.0
9.0
1.2
1.2
1.2
1.2
U -Value
x
x
X
x
X
X
X
x
x
x
x
x
X
x,
X
x
X
x
X
X
X
X
x
X
x
x
X
X
x
x
X
x
X
x
x
x
x
x
x
X
AT of
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=147
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
44
758
44
456
44
734
44
1,031
44
147
44
147
44
147
44
330
44
533
44
452
5
44
342
44
1,006
44
19
44
44
19
19
4_4
410
44
147
44
147
44
147
4_4
44
6.6.9
147
44
147
44
4-4
1.9
44
19
44
19
4
-4-4-
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 8 624
Infiltration: [ 1.001 x 1.064 X 575 X 9.00 x 0.524 / 60] x 44 = 2,116
Schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 10,740
EnergyPro 4.2 by EnergySoft User Number: 5862 'Job Number: Page: 23 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
roject Title Date
itrhPll RPsiripnrp R/:An/g(if1R
Room Information Desi n Conditions
Room Name: Master Suite Sr Bedrooms
Outdoor Dry Bulb Temperature: 1120F
Floor Area: 1,577 sf
Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72OFOutdoor
Daily Range: 340F
•
1�1
Opaque Surfaces
R-38 Roof R.38.2x14.16
R-21 Wall (W.21.2x6.16)
R-21 Wall W.21.2x6.16
R-21 Wall W.21.2x6.16
R-21 Wall W.21.24.16
R-21 Wall W.21.24.16
R-21 Wall (W.21.24.16)
R-21 Wall (W.21.24.16)
Orientation
A.o!2
N 1,497.0
N 675.4
(E 284.2
SE 24.6
S 264.6
SW 55.6
(W) 224.8
(NW) '44.0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Glazi
U -Factor CLTD 1 Btu/hr
x
x
x
x
x
x
X
x
x
x
x
x
0.0201
X
X
X
X
X
X
X
X
x
x
x
x
56.0
=
=
=
=
=
=
=
=
=
_
_
1,683
0.0690
23.0
1,072
0.0690
33.0
647
0.0690
31.0
53
0.0690
26.0
475
0.0690
31.0
119
0.0690
33.0
512
0.0690
30.2
92
19.6
9.0
19.6
N
0.0X
19.6+
24.0X
19.6=
N
0.0
--
9.0
Page Total 4 652
Orientation
Btu/hr
Shaded
Area
x
x
x
x
X
x
X
GLF
+
+
+
+
+
+
+
Unshaded
Area
x
X
x
x
x
X
X
Page
GLF
=
=
=
=
=
=
_
=
N
0.0
19.6
9.0
19.6
U
0.0
19.6
21.2
19.6
(N)
0.0
19.6
21.2
19.6
N
0.0
19.6
9.0
19.6
N
0.0X
19.6+
24.0X
19.6=
N
0.0
19.6
9.0
19.6
N
0.0
19.6
31.1
19.6
N
0.0x
19.6+
25.0X
19.6-
E
0.0x
19.6+
72.2X
39.
(E)
O.Ox
19.6+
[:: 34.2x
Total
Btu/hr
Internal Gain
Btu/hr
Occu ants
4
x Occupants x 230 Btuh/occ. =
920
E ui ment
x Dwelling Units x 1,600] Watts/sgft =
1,6001
Infiltration: 1.064 x 1.24 x 99.92 X 40 =
5 276
Air Sensible CFM ELA ZST
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
29 794
Latent Gain
Btu/hr
Occupants 0 x Occupants x 200 Btuh/occ. =
800
Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 =
57
Air Latent CFM ELA pw
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
857
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:24 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
W'O'ecttTitle Date
itchell Residence �i/30/2006
Room Information Design Conditions;
Room Name: Master Suite & Bedrooms
Outdoor Dry Bulb Temperature: 1120F
Floor Area: 1,577 sf
Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72OFOutdoor
Daily Range: 340F
. Opaque Surfaces
Orientation
Area
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
•
Glazing
Glazing
Glazing
Glazing
Glazing
Glazing
Glazing
.Glazing
Glazing
Glazing
U -Factor CLTD 1 Btu/hr
x
x
x
x
x
x
x
x
x
x
x
x
Btu/hr
x
x
x
x
x
x
x
x
x
x.
x
x
x
x
x
X
X
=
=
-
=
=
=
=
=
=
_
=
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
Page
GLF
=
=
=
=
=
U
0.0x
19.6+
85.0x
39.2=
U
0.0x
19.6+
14.8X
39.2=
E
0.0x
19.6+
4.7X
39.2=
SE
0.0x
19.6+
14.8x
27.2=
SE
0.0X
19.6+
4.7X
27.2=
S
Page Total 0
;Orientation
Btu/hr
Shaded
Area
x
x
x
X
X
GLF
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
Page
GLF
=
=
=
=
=
U
0.0x
19.6+
85.0x
39.2=
U
0.0x
19.6+
14.8X
39.2=
E
0.0x
19.6+
4.7X
39.2=
SE
0.0x
19.6+
14.8x
27.2=
SE
0.0X
19.6+
4.7X
27.2=
S
0.0
19.6
14.8
19.7
S
0.0
19.6
4.7
19.7
S
0.0
19.6
34.0
19.7
S
0.0
19.6
34.0
19.7
SW
0.0x
19.6+
14.8x
Total
Btu/hr.
- Internal Gain
Btu/hr
Occupants 4 X Occupants x 230 Btuh/oCC. =
920
E ui ment X Dwelling Units X 1,6001 Watts/sqft =
1,6001
Infiltration: 1.064 x 1.24 X 99.92 x 40 =
5 276
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
29 794
j
Latent Gain
Btu/hr
Occupants � X Occupants x 200 Btuh/oCC. =
800
Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 =
57
Air Latent CFM ELA pW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
857
Energy Pro 4.2 by EnergySoft User Number: 5862 Job Number:
Page:25 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Wo,ect Title Date
it -hell Residence 8/3()/gnnF
Room Information Desicin Conditions
Room Name: Master Suite & Bedrooms
Outdoor Dry Bulb Temperature: 1120F
Floor Area: 1,577 sf
Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72OFOutdoor
Daily Range: _ 340F
opaque 5urtaces
Orientation Area
U -Factor
x
x
(SW)
x
x
x
X
x
X
x
x
X
x
X
x
x
x
4.7
x
x
=
=
=
x
x
19.6+
x
x
(�
x
x
72.2X
x
x
Occupants F--41 x Occupants x 200 Btuh/occ. =
x
x
57
x
x
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
x
x
x
CLTD 1
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF ' Area GLF
•
Page Total
Btu/hr
0
Btu/hr
127
518
2,835
3,480
Internal Gain
(SW)
0.0
X
x
X
x
x
X
x
X
x
19.6
+
+
+
+
+
+
+
+
+
4.7
X
x
X
X
X
X
X
X
x
27.2
=
=
=
(SWC
17.8X
19.6+
6.2X
27.2=
(�
0.0x
19.6+
72.2X
39.2=
Btu/hr
Occupants F--41 x Occupants x 200 Btuh/occ. =
800
Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 =
57
Air Latent CFM ELA pW
•
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
857
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page:26 of 32
Page Total
Btu/hr
0
Btu/hr
127
518
2,835
3,480
Internal Gain
Btu/hr
Occupants
4
F1
X Occupants x 230 Btuh/occ. =
920
X Dwelling Units X 1'6001 Watts/sqft =
1 600
Infiltration: 1.064 X 1.24 x 99.92 X 40 =
5276
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
29 794
Latent Gain
Btu/hr
Occupants F--41 x Occupants x 200 Btuh/occ. =
800
Infiltration: 4 771 x 1.24 x 99.92 x 0.00010 =
57
Air Latent CFM ELA pW
•
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
857
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page:26 of 32
E ui ment 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
roject Title Date
, itrhPll RPsiriPnrP R/Rfl/9mr,
Room Information Design Conditions
Room Name: Living
Outdoor Dry Bulb Temperature: 1120F
Floor Area: 2,941 sf
Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72OFOutdoor
Daily Range: 340F
Opaque Surfaces
R-38 Roof (R.38.2x14.16)
R-21 Wall W.21.2x6.16
R-21 Wall W.21.2x6.16
R-21 Wall W.21.2x6.16
R-21 Wall W.21.24.16
R-21 Wall W.21.2x6.16
R-21 Wall (W.21.2x6.16)
Wood Door
Orientation
Area
x
X
X
X
X
X
X
X
X
X
x
X
U -Factor
X
X
X
X
X
X
x
X
X
X
X
X
CLTD 1
=
=
=
=
=
=
=
=
Btu/hr -
N
2,662.0
0.0201
56.0
2,993
N
316.7
0.0690
23.0
503
E
345.9
0.0690
33.0
788
(SE)
26.0
0.0690
31.0
56
(S
714.6
0.0690
26.0
1,282
SW
25.0
0.0690
31.0
53
(W)
585.8
0.0690
33.0
1,334
(W)
24.0
0.5000
33.0
396
111.8
39.2
U
30.3
19.6
0.0
39.
(E
0.0x
19.6+
72.2X
39.2=
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Internal Gain
Occupants B4
Equipment 1
Page I otal 17404
Orientation
Shaded
Area
X
X
X
x
x
X
X
GLF
+
+
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
x
X
Page
GLF
=
=
=
=
_
=
N
0.0x
19.6+
24.0x
19.6=
N
0.0
19.6
55.2
19.6
N
0.0
19.6
15.1
19.6
N
0.0x
19.6+
38.9x
19.6=
(E)
0.0
19.6
61.7
39.2
(E
0.0x
19.6+
72.2X
39.2=
E
0.0
19.6
19.8
39.2
(E
0.0
19.6
111.8
39.2
U
30.3
19.6
0.0
39.
(E
0.0x
19.6+
72.2X
39.2=
Total
Btu/hr
Btu/hr
X Occupants X 230 Btuh/oCc. = 920
X Dwelling Units X 1,600] Watts/Sgft 1 1.6001
Infiltration: 1.064 x 1.24 x 186.34 x 40 = 9 840
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9941
Latent Gain Btu/hr
occupants 1 4 Occupants X 2001 Btuh/oCc. = 800
Infiltration: 4 771 X 1.24 X 186.34 X 0.00010 = 106
• Air Latent CFM ELA ,nW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 27 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
oject Title Date
L'litrhpll
RPcirlPncP 8/m/9nnA
Room Information Desi n Conditions
Room Name: Living
Outdoor Dry Bulb Temperature: 1120F
Floor Area: 2,941 sf
Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72 of
Outdoor Daily Range: 340F
Opaque Surfaces
Orientation Area U -Factor
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
•Glazing
Glazin
Glazing
Glazing
Glazing
Glazing
Glazing
CLTD 1
Page Total
Orientation
x
x
X
x
X
X
X
X
x
X
X
X
X
x
X
X
X
X
x
X,
X
x
x
X
x
X
X
x
x
x
X
X
x
+
+
+ -
+
+
+
+
+
Unshaded
Area
X
x
X
X
x
X
X
x
GLF
E
0.0
19.6
19.8
39.2
UE
0.0
19.6
30.3
39.2
E
23.7X
19.6+
0.3X
39.2
(SE)
0.0
19.6
24.0
27.2
S
1.2
19.6
0.0
19.7
U
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
•Glazing
Glazin
Glazing
Glazing
Glazing
Glazing
Glazing
CLTD 1
Page Total
Orientation
.Shaded
Area
X
x
X
X
X
X
x
X,
X
GLF
+
+
+ -
+
+
+
+
+
Unshaded
Area
X
x
X
X
x
X
X
x
GLF
E
0.0
19.6
19.8
39.2
UE
0.0
19.6
30.3
39.2
E
23.7X
19.6+
0.3X
39.2
(SE)
0.0
19.6
24.0
27.2
S
1.2
19.6
0.0
19.7
U
1.2
19.6
10.0
19.7
1.2
19.6
0.0
19.7
U
0.0
19.6
28.0
19.7
(S)
0.0x
19.6+
58.5X
19.
S
0.01
19.6+
55.2x
19.7
Page Total
Btu/hr
Btu/hr
777
=
1,189
477
654
23
23
23
552
1,154
_ •1090
5 962
' Internal Gain
Btu/hr
Occupants 4 X Occupants X 230 Btuh/occ. = 920
E ui ment 1 X Dwelling Units X 1,600] Watts/sgft = '1,60
+ Infiltration: Cosa x tea x 186.34 x a = '9,8401
Air Sensible CFM ELA Z�,T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9
Latent Gain Btu/hr
Occu ants 4 x Occupants x 200 Btuh/occ. = 800
Infiltration: 4,771 x 1.24 x 186.34 x 0.00010 = 106
Air Latent CFM ELA pW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:28 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
ro�ect Title Date
itchell Residence 8/30/2006
Room Information Desi - n Conditions
Room Name: Living Outdoor Dry Bulb Temperature: 1120F
Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72 o Outdoor Daily Range: 340F
•
0
ue 5urtaces
Orientation Area
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Internal Gain
Occupants 4
E ui ment 1
U -Factor
x
x
x
x
x
GLF
x
x
X
Page
x
x
(S)
x
x
15.1x
x
x
0.0x
x
x
39.2=
x
x
19.6+
x
x
W
x
x
0.0x
x
x
6.8X
x
CLTD 1
Page Total
Orientation
Shaded
Area
X
GLF
+
Unshaded
Area
X
Page
GLF
=
(S)
0.0x
19.6+
15.1x
19.7
(W
0.0x
19.6+
36.0X
39.2=
U
0.0x
19.6+
36.0X
39.2=
W
6.8x
19.6+
0.0x
39.2=
(W
6.8X
19.6+
0.0x
39.2=
(YJV
0.0x
19.6+
29.8X
39.2=
W
10.5X
19.6+
0.0x
39.2=
(YJV
0.0x
19.6+
36.0X
39.2=
W
6.8x
19.6+0.0x
(W
0.0x
19.6+
36.Ox
Total
Btu/hr
0
Btu/hr
Btu/hr
x Occupants X 230 Btuh/oCC. = 920
X Dwelling Units x 1,6001 Watts/sgft = 1.600
Infiltration: 1.064 X 1.24 X 186.34 X 9 840
Air Sensible CFM ELA OT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 53,9
Latent Gain Btu/hr
Occupants ® X Occupants x 200 Btuh/oCC. E800
Infiltration: 4 771 X 1.24 X 186.34 X 0.00010 = 106
• Air Latent CFM ELA pW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 906
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:29 of 32
RESIDENTIAL ROOM COOLING LOAD SUMMARY
roject Title Date
it
chell Residence 8/30/2006
Room Information Desi n Conditions
Room Name: Living Outdoor Dry Bulb Temperature: 1120F
Floor Area: 2,941 sf Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F
Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr
•
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Page Total 0
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF Btu/hr
s
(W
'
6.8X
X
X
x
x
x
x
x
X
19.6+
+
+
+
+
+
+
+
+
0.0x
X
X
x
X
x
x
X
x
39.2=
=
=
=
-
=
133
VM
0.0
19.6
36.0
39.2
1,413
W
6.8x
19.6+
0.0x
39.2=
133
IM
0.0x
19.6+
19.0x
39.2=
746
W
0.0
19.6
42.2
39.2
1,658
s
E ui ment 1
Page Total a o81
Internal Gain
Btu/hr
Occupants 4 X Occupants x 230 Btuh/oCC. =
920
X Dwelling Units x 1,600] Watts/sgft =
1,60
Infiltration: 1.064 X 1.24 x 186.34 X =
9,8401
Air Sensible CFM ELA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
53 994
Latent Gain
Btu/hr
Occupants x Occupants x 200 Btuh/oCC. =
800
Infiltration: 4 771 x 1.24 X 186.34 x 0.00010 =
106
Air Latent CFM ELA pW
•
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
906
EnergyPro 4.2 by EnergySoft: User Number: 5862 Job Number:
Page:30 of 32
E ui ment 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
0 roject Title Date
itrhPll RPciHPnra R/,Afl/gnnA
Room Information
Desicin Conditions
X
X
X
X
X
X
X
X
X
X
X
X
Room Name:
2ns Floor & Studio
Outdoor Dry Bulb Temperature:
1120F
Floor Area:
575 sf
Outdoor Web Bulb Temperature:
730F
Indoor Dry Bulb Temperature:
72 of
Outdoor Daily Range:
340F
Opaque Surfaces
R-19 Floor No Crawls ace
R-19 Floor No Crawls ace
R-38 Roof R.38.2x14.16
R-21 Wall W.21.2x6.16
R-21 Wall (W.21.2x6.16)
R-21 Wall W.21.24.16
R-21 Wall (W.21.24.16)
Orientation
Area
X
X
X
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
X
X
x
CLTD 1
=
=
=
=
=
=
=
Btu/hr
=
=
=
=
359.0
0.0480
19.0
327
0.0
216.0
0.0480
19.0
197
(N
575.0
0.0201
56.0
646
(N
339.8
0.0690
23.0
539
E
175.5
0.0690
33.0
400
S
331.3
0.0690
26.0
594
(W)
220.3
0.0690
33.0
502
1.2
19.7
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
• Glazing
Glazin
Glazing
Glazing
Glazing
Glazina
Orientation
N
N
N
N
E
E
E
S
S
S
r-ayc 1 uiai I a,[uol
Shaded Unshaded
Area GLF Area GLF Btu/hr
Occupants 4
E ui ment _ 1
0.0
X
X
x
x
x
x
X
19.6
+
+
+
+
+
+
+
9.0
X
X
X
X
X
X
X
19.6
=
=
=
=
0.0
19.6
9.0
19.6
0.0
19.6
9.0
19.6
0.0x
19.6+
20.2X
19.6=
0.0X
19.6+
27.7X
39.2=
0.0x
19.6+
27.7X
39.2=
0.0x
19.6+
21.0X
39.2=
0.0
19.6
1.2
19.7
0.0
19.6
1.2
19.
0.0
19.6
1.2
19.7
Occupants 4
E ui ment _ 1
Page Total 3 998
Internal Gain
Btu/hr ,
BX Occupants X 230 Btuh/occ. =
920
X Dwelling Units X 1,6001 Watts/Sgft =
1,6001
Infiltration: 1.064 X 1.24 X 36.43 x 40 =
1924
Air Sensible CFM ELA OT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13 920
Latent Gain
Btu/hr
Occu ants F4 x Occupants x 200 Btuh/occ. =
800
Infiltration: 4 771 X 1.24 X 36.43 X 0.00010 =
21
Air Latent CFM ELA n w
•
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
821
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page: 31 of 32
Occupants 4
E ui ment _ 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
cTitle' Date
ko'e
itchell Residence 8/30/200.6
Room Information Desicin Conditions
Room Name: 2ns Floor & Studio Outdoor Dry Bulb Temperature: 1120F
Floor Area: 575 sf Outdoor Web Bulb Temperature: 730F
Indoor Dry Bulb Temperature: 72'FOutdoor Daily Range: 340F
is
ue surraces
Orientation Area U -Factor CLTD 1
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
G
rage I otal
Btu/hr
0
Orientation
x
x
x
x
x
x
x
x
x
x
x
x
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
+
+
+
=
=
=
=
=
=
=
=
=
=
=
=
X
X
X
X
GLF
=
=
=
Btu/hr
(S
0.0
19.6
25.2
19.7
496
S
0.0x
19.6+
9.0x
19.7=
178
(�
0.0
.19.6
9.0
19.7
178
S
0.0x
19.6+
9.0x
19.7=
178
W
0.0X
19.6+
9.0X
39.2=
353
0.0x
19.6+
9.0x
39.2=
353
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
G
rage I otal
Btu/hr
0
Orientation
Shaded
Area
X
X
X
GLF
+
+
+
Unshaded
Area
X
X
X
X
GLF
=
=
=
Btu/hr
(S
0.0
19.6
25.2
19.7
496
S
0.0x
19.6+
9.0x
19.7=
178
(�
0.0
.19.6
9.0
19.7
178
S
0.0x
19.6+
9.0x
19.7=
178
W
0.0X
19.6+
9.0X
39.2=
353
0.0x
19.6+
9.0x
39.2=
353
0.0x
19.6+
9.0X
39.2=
353
W
0.0x
19.6+
1.2X
39.2=
46
U
0.0x
19.6+
1.2X
39.2
46
W
0.0x
19.6+
39.2=
46
---!I
I
Page Total 2 226
Internal Gain Btu/hr
Occu ants 4 x Occupants X 230 Btuh/occ. = 920
E ui ment X Dwelling Units X 1,600] Watts/sgft = 1,600
Infiltration: 1.064 X 1.24 X 36.43 X ��40 = 1924
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 920
Latent Gain Btu/hr
Occu ants ® X Occupants. x 200 Btuh/occ. = 800
Infiltration: 4 771 X 1.24 X 36.43 X 0.00010 = 21
Air Latent CFM ELA pW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 821].
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 32 of 32
r
A
r
TITLE 24 REPORT
Title 24 Report for:
Mitchell Casita
52958 Via Dona
La Quinta, CA 92253
` 4 r
Project Designer:
< RAM Companies
1544 Eureka Rd #140 .
Roseville, CA 95661
} , 916-789-1400 `
} Report Prepared By: t
• Sheila Munson
'Eagle Quest Specialties, Inc.
42335 Washington Suite_ F #330
Palm Desert, CA 92211 M
(760) 3454859
41
Job Number:
'Date:
8/30/2006 y
he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
uthorized by the California Energy Commission for use with both the.Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by EnergySoft Job Number: User Number: 5862
A ,�
.r
h .. - - y i
..- �i. s
.. ..
�
J
�
� ..
.a�
+ +
Certificate Of Compliance :
Residential
❑ Addition
(Part 1 of 4) CF -1 R
Altchetle as.ita
ft2
Root_ Wood- 440_
8/_3012QQ6
Title
Project -
-52-9 5-8-M
Existing Floor Area:
'
Date
Project Address
(E) 90 deg
Raised Floor Area:
Building Permit #
�aq-e__Quest_S_peci.alties.,_I.nc.
Doc mentation Author
Fuel Type:
(760) 345-4859
Telephone
Plan Check/Date
EneLgVEro
Compi ce Method
440
15
Climate Zone
Field Check/Date
TDV Standard
Proposed Compliance
Average Ceiling Height:
_(kBtu/sf- r) Design
Design
Margin
184 ft2
Space Heating 2.49
2.35
0.14
Space Cooling 92.18
88.98
3.20
1
Fans 14.01
15.80
-1.79
Domestic Hot Water 0.00
0.00
0.00
Pumps 0.00
0.00
0.00
Area
Totals 108.67
107.12
1.55
x._00_ Conditioned- -Setback-
Percent better than Standard:
-n/a
1.4%
Building Type:
MJ Single Family
❑ Addition
Total Conditioned Floor Area:
440
ft2
Root_ Wood- 440_
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a
ft2
Building Front Orientation:
(E) 90 deg
Raised Floor Area:
0
ft2
Fuel Type:
Wall- Wood_ 220_
Natural Gas
Slab on Grade Area:
440
ft2
Fenestration:
Wall- Wood- 37_
-0_0.69_ R-21 -R=0_0_--27.0_
Average Ceiling Height:
10.0
ft
Area:
184 ft2
Avg. U: 0.37
Number of Dwelling Units:
1.00
Ratio:
41.9% Avg. SHGC: 0.30
Number of Stories:
1
UILDING ZONE
INFORMATION
# of Thermostat
Vent
one Name
Floor Area Volume
Units Zone Type Type
Hgt.
Area
Casita
44.0 4,400
x._00_ Conditioned- -Setback-
2
-n/a
OPAQUE SURFACES
Insulation Act.
New
New
Type Frame Area
U -Fac. Cay. Cont. Azm.
Tilt
Root_ Wood- 440_
_0_029_ -R3.8_ X0_0_ -0-
0_Wall_
Ne.w
New
Wall --63--0-069-
-R-21 _E2_0_0_ 0_-90
Wall_ Wood_ x.83_
_0_0.6.9_ R-21 --R-0_0_--4.5_
9.0
Wall- Wood- 24
-0-069---R--2-1---R--O-O--90--90
Wall- Wood_ 220_
_0_0.6.9- R-21 JRm0...0_---t3.5__9.0
Wall- Wood_ 18.5_
_0..06.9_ -R21 X0_0_ _2259.0
Wall- Wood- 37_
-0_0.69_ R-21 -R=0_0_--27.0_
9.0
Wall_ Wood- 123_
_0.069_ -R21. _IR0.0_ -315.9.0
Gains Condition
Y / N Status
JA IV Reference Location / Comments
New 02-A11
Casita
New
New
_0.9=96
09-
Casita
Casita
New
Ne.w
N.ew
_0.9_A6
-09=A6-
_0.916
Casita
Casita
Casita
Ne.w
New
_0.9=96
_09-
C.asita
Casita
I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:3 of 13 1
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Ah Itchell Casita 8/30/2006
roject Title Date
FENESTRATION SURFACES
# Type Area U -Factor' SHGC2
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
_'L
2
Win.dow--Right_(.N)_ 1227_
Window Right (N)_ 4.0
-0.3.7-0 _NERC _0.3.0 -NERC.
0.370 NFRC 0_30 NFRC
0_
0
-9.0- N.ew Mandatory -Minimum
90 New Mandatory Minimum
Casita
Casita
3
Window
Right U, 12.7
0.370 NFRC 0_30 NFRC
45
90 New
Mandatory Minimum
Casita
4
WindowRight
U. 4.0
0.370 NFRC 0_30 NFRC
45
90 New
Mandatory Minimum
Casita
5
Window
Front (E)_ 25.5
0.370 NFRC 0_30 NFRC
90
90 New
Mandatory Minimum
Casita
6
Window
Left (SW) 21.2
0.370 NFRC 0_30 NFRC
225
90 New
Mandatory Minimum
Casita
L
Window
Left (SW)37
-O-3B N F 3 C 0.30 NFRC 225
9QLlew
Maa ato_ry Minimum
Casita
8
Window
Left U 12.7
0.370 NFRC 0.30 NFRC
225
90 New
Mandatory Minimum
Casita
5
10
Window Left (SW) 4.0
Windgw Rear (W)- 4.0
0_3Z0 NFRC J 30 NERC 225
9,37-0 NFRC -0- 30 NERC 270_
90 Ll we Mand Minimum
90 New MarAdato_ryMinimum
Casita
Carta
Window
Rear (W)- 4.0
0.370 NFRC 0_30 NFRC
270
90 New
Mandatory. Minimum
Casita
12
Window
Rear (W)- 12.7
0.370 NFRC 0_30 NFRC
270
90 New
Mandatory Minimum
Casita
13
14
Window_Rear(.W)- 12.7-
Window Rear (NW) 12.7
-0-37-0 -NER.C_0_30 NFRC _270_
0.370 NFRC 0_30 NFRC
315
90 New
90 New
M.and.atopy-Minimum
Mandatory Minimum
Casita
Casita
15
Window
Rear CNW) 4.0
0.370 NFRC 0_30 NFRC
315
90 New
Mandatory Minimum
Casita
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168
INTERIOR AND EXTERIOR SHADING Window Overhang I Left Fin Right Fin
# Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
JA IV Reference
Bug Screen
0.76
Concrete, Heavyweight
Bug Screen
0.76 8.5 3.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0.0 0.0 0
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Buq Screen
0.76
14 Bug Screen 0.76
15 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
r�
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:4 of 13 1
Area Thick. Heat
Inside
Condition
Location/
Type
(so
(in.) Cap.
Cond. R -Val.
JA IV Reference
Status
Comments
Concrete, Heavyweight
150
4.00 28
0.98 0
26-A1
New
Casita / Slab on Grade
Concrete, Heavyweight
290
4.00 28
0.98 2
26-A1
New
Casita / Slab on Grade
Condition
PERIMETER LOSSES
Insulation
Location/
Type
Length
R -Val.
Location
JA IV Reference
Status
Comments
Slab Perimeter
33
None No Insulation
26-A1
New
Casita
Slab Perimeter
69
None No Insulation
26-A1
New
Casita
r�
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:4 of 13 1
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
Aft,lItchell Casita 8/30/2006
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum, Condition Thermostat
Location Type Eff Type Eff Status Type
Casita Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback
HVAC DISTRIBUTION
Duct
Location Heating Cooling Location
Casita Ducted Ducted Attic
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Duct Condition Ducts
R -Value Status Tested?
4.2 New Yes
WATER HEATING SYSTEMS Rated l Tank Energy Standby! Tank Insul.
.Water Heater # in Input Cap. Condition Factor Loss . R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump
Control # HP
Hot Water Piping Length (ft) Add 1/2"
In Plenum Outside Buried Insulation
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: H ; M Garwe j -a t Name: Sheila Munson
Title/Firm: RAM Companies Title/Firm: Eagle Quest Specialties, Inc.
Address: 1544 Eureka Rd #140 Address: 42335 Washington Suite F #330 _
Roseville, CA 95661 Palm Desert, CA 92211 _
Telephone: 916-789-1400 Telephone: (760) 345-4859
Lic. #: 40 2140113
4 3 6%
(signature) I t(dat6) (signature) (date)
Enforcement Agency
Name:
Title/Firm:
dress:
lephone:
(signature/stamp)
5of13
Certificate Of Compliance: Residential (Part4 of 4) CF-1R
',Mitchell Casita 8/30/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
ddequacy of the special justification and documentation submitted. Plan Field
Multiple Dwelling Units are served by a common water heater. Verify DHW details on Part 3 of the CF -1 R.
The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
HIGH MASS Design - Verify Thermal Mass: 150 sgft Exposed Slab Floor, 4.00" thick at Casita
HIGH MASS Design - Verify Thermal Mass: 290 sgft Covered Slab Floor, 4.00" thick at Casita
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R pian Field
installation certificate.
�he HVAC System "Casita" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
=Cooling
ystem "Casita" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve.
System "TRANE 4TTX4024/TUD60R936 (2)" includes credit for a 11.5 EER Condenser. A certified HERS rater must
field verify the installation of the correct Condenser.
Run Initiation Time: 08/30/06 11:53:50 Run Code: 1156964030
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 13
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
• requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
y they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
❑
❑ •
f§150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
Q
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
�§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
1
❑ •
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ..
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
. b. outside air intake with damper and control, flue damper and control
❑
❑
,❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual
El1:1El
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑X
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
+
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑X
El
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
❑
❑
❑
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑
❑
• 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑X
❑
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑
❑ •
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑X
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑„
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page:7 of 13
C]
•
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not
ENFORCE -
applicable.
N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ X❑ ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑ ❑X ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑ ® ❑
.duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
❑ ❑ ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑ ❑ ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ - ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑ ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118. (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ X❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ Q ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ x ❑
controlled by an occupant sensor that complies with Section 1' 9(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ Q ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number:
Page:8 of 13
r.�
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Id ROJECT NAME DATE
Mitchell Casita 8/30/2006
SYSTEM NAME FLOOR AREA
Casita 440
ENGINEERING CHECKS SYSTEM LOAD
Number of Systet
Heating System
Output per Systen
Total Output (Btut
Output (Btuh/sqft)
Cooling System
Output per System
Total Output (Btuh)
Total Output (Tons)
Total Output (Btuh/sgft)
Total Output (sgft/Ton)
CFM per System
Airflow (cfm)
Airflow (cfm/sgft)
Airflow (cfm/Ton)
I Outside Air (%)
Outside Air (cfm/sgft)
Note: values above given at ARI conditions
IEATING SYSTEM PSYCHROMETRICS
1
47,000
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
47,000
106.8
CFM
24,000
24,000
2.0
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel Latent
CFM
I Sensible
628
11,354
816
295
10,993
at Time of Coolinq
0
111.0/72.5°F
78.8/62.8°F 78.8/62.8°F
1,177
1,015
0
0
115
4,601
-106
115
5,239
0
Supply Fan Cooling Coil
0
11177
1,015
18.310 710
ovu
800 TRANE 4TTX4024rrUD60R936 (2) 20,394 300
1.82
400.0
14.4 Total Adjusted System Output 20,394 300
(Adjusted for Peak Design Conditions)
0.26 TIME OF SYSTEM PEAK F Aug 2 pm
m TemDeratures at Ti
47,000
47,000
Jan 12 am
26.0 OF 62.7 OF 62.7 OF 105.0 °F
O Supply Air Ducts
Outside Air
115 cfm 103.8 OF
Supply Fan Heating Coil
800 cfm ROOMS
68.8 OF 70.0 °F
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 13
Return Air Ducts S
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures
at Time of Coolinq
Peak)
111.0/72.5°F
78.8/62.8°F 78.8/62.8°F
55.0/53.7°F
Supply Air Ducts
Outside Air
115 cfm
Supply Fan Cooling Coil
56.4 / 54.3 of
800 cfm
ROOMS
51.7% R.H.
72.0!60.5°F
'3.4/61.0°F
24
Return Air Ducts
I
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 13
_ rr
ROOM LOAD SUMMARY
EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 13
i
ROJECT NAME
Mitchell Casita
DATE
8/30/2006
SYSTEM NAME
Casita
FLOOR AREA
440
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Casita
Casita
1
628
11,354
816
628
11,354
816
295
10,993
t
' PAGE TOTAL 1 6281 11,354 816 295 10,993
TOTAL 1 628 11,354 816 295 10,993
EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 13
i
t
ROOM HEATING PEAK LOADS
Wofect Title Date
itrhPn casita is/m/9nnR
Room Information Desi n Conditions
Room Name Casita
Time of Peak Jan 12 am
Floor Area 440
Outdoor Dry Bulb Temperature 26 OF
Indoor Dry Bulb Temperature 70 OF
X
x
x
x
x
x
x
X
X
X
X
x
X
X
x
x
X
X
X
X
x
x
X
X
x
x
X
X
X
x
x
x
x
X
X
X
X
X
X
X
Conduction
U -Value
-n-
R-38 Roof R.38.2x14.16)
surface
Area
440.0
x
x
x
x
x
x
x
x
x
x
x
X
x
X
`x
X
x
x
X
x
X
x
X
X'
X
x
X
X
X
x
X
X
X
x
x
x
x
x
x
X0.472
0.0290
X
x
x
x
x
x
x
X
X
X
X
x
X
X
x
x
X
X
X
X
x
x
X
X
x
x
X
X
X
x
x
x
x
X
X
X
X
X
X
X
44
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_
=
=
=
561
R-21 Wall (W.21.2x6.16)
63.3
0.0690
44
192
Mandatory-_M.inim.um
12.7
0.3700
44
206
Mandatoy Minimum
4.0
0.3700
44
65
V_1ia1L(W.21.2x6.J
183.3
0.0690
44
557
Mandatory Minimum
12.7
0.3700
44
206
an -da] Minim m
4.0
0.3700
44
65
R-21 Wall W.21.24.16
24.5
0.0690
44
74
andatoLy-Minimu
25.5
0.370
44
415
R-21 Wall .21.2x6.16
220.0
0.0690
44
668
- _LWalL(-W 21.2x6.16.)
184.6
0.0690
44
5.6.0
346
Mandato Minimum
21.2
0.3700
44
Mandato1y Minimum
37.5
0.3700
44
610
Mandato Minimum
12.7
0.3700
44
206
an.datoiy_Minim.um
4.0
0.3700
6.5
R21_W.a1L(_W_212x6A6.)
36.7
0.0690
44
111
andato*Minimum
Q
-0-3700
0.3700
44
65
i Um
4.0
44=
65
�Mandat4[y
ulan a ory Minimum
12.7
0.3700
44
206
'Slab
Allandatory-Minimum.12.7
0.3700
44
206
-2_LWall (W 21-2x6-16.)
2
44
3.7
Mandato Minimum
12.7
-0-00Q
0.3700
44
206
Mandato Minimum
4.0
0.3700
44
65
-On -Grade
perimeter = 33.0
0.7300
44=1,060
Slab= -On
perimeter = 69.0
0.7300
216
Items shown with an asterisk (•) denote conduction through an interior
Infiltration: 1 1.00 x 1.064 x
chedule AIr Sensible
Fraction
to another room.
440 x 10.00
Ceiling Height
/ 60]
ACH
Page Total:
44
&T
9 374
1 619
TOTAL HOURLY HEAT LOSS FOR ROOM 10,993
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 11 of 13
V
RESIDENTIAL ROOM COOLING LOAD SUMMARY
W
oject Title Date
itrhPll Casita R/.monnA
Room Information
Desicin Conditions
U -Factor
Room Name:
Casita
Outdoor Dry Bulb Temperature:
1120F
Floor Area:
440 sf
Outdoor Web Bulb Temperature:
730F
Indoor Dry Bulb Temperature:
72OFOutdoor
Daily Range:
340F
•
Opaque Surfaces
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall W.21.2x6.16
R-21 Wall (W.21.2x6.16)
R-21 Wall .21.24.16
R-21 Wall .21.24.16
R-21 Wall (W.21.24.16)
R-21 Wall (W.21.24.16)
Orientation
Area
X
X
X
X
X
X
x
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
x
X
X
X
CLTD 1
440.0
0.0201
56.0
63.3
0:0690
23.0
183.3
0.0690
29.0
24.5
0.0690
33.0
220.0
0.0690
31.0
184.61
0.0690
31.0
36.7
0.0690
33.0
123.3
0.0690
30.2
(E
9.3X
18.5+
16.2X
36.3
SSW)
0.0x
18.5+
21.2X
25.4
(SW)
0.0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Glazi
Internal Gain
Occupants 4
E ui ment 1
Nage i otal
Orientation
Shaded
Area
X
'X
X
X
x
x
X
X
GLF
+
+
+
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
X
X
GLF
(�
0.0
18.5
12.7
18.5
N
0.0
18.5
4.0
18.5
(NE)
0.0
18.5
12.7
28.2
(NE)
0.0
18.5
4.0
28.2
(E
9.3X
18.5+
16.2X
36.3
SSW)
0.0x
18.5+
21.2X
25.4
(SW)
0.0
18.5
37.5
25.4
SW
0.0x
18.5+
12.7X
25.4
SW
0.0
18.5
4.0
25.4
(_W)
0.0
18.5
4:-0
36.3
X Occupants X -2301 Btuh/oCC. =
x Dwelling Units X 1,6001 Watts/sgft =
Page Total
Btu/hr
495
101
367
56
471
395
84
257
2 224
Btu/hr
235
74
357
113
= 761
541
954
322
102
145
3 603
Btu/hr
920
1 600
Infiltration: 1.064 X 1.24 X 27.88 X 1 1472
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11 354
Latent Gain Btu/hr
Occupants ®x Occupants X 200 Btuh/oCC ` = 800
Infiltration: 4 771 X 1.24 x 27.88 x 0.00010 = 16
Air Latent CFM ELA pW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 816
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 12 of 13
4-
RESIDENTIAL ROOM COOLING LOAD SUMMARY
0
�ro�ectr,hTitle Date
itPn i":acitn �R/,in/qnm
Room Information
Design Conditions
X.
x
x
x
x
x
x
x
x
x
x
X
Room Name:
Casita
Outdoor Dry Bulb Temperature:
1120F
Floor Area:
440 sf
Outdoor Web Bulb Temperature:
730F
Indoor Dry Bulb Temperature:
72 of
Outdoor Daily Range:
340F
Opaque Surfaces
Orientation Area U -Factor CLTD I
Items shown with an asterisk(*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
•Glazing
Glazing
Glazing
Glazin
Glazing
rage I oial
Btu/hr
0
Orientation
Btu/hr
X.
x
x
x
x
x
x
x
x
x
x
X
X
X
x
X
X
X
X
X
x
X
x
x
x
x
x
x
x
x
x
x
x
x
+
+
+
+
+
+
+
+
+
+
=
=
=
=
=
=
=
=
=
-
=
=
X
X
X
X
X
x
X
X
X
X
Page
GLF
=
=
=
=
=
=
=
=
=
=
Btu/hr
(�
0.0x
18.5+
4.0x
36.3=
145
(W)
0.0
18.5
12.7
36.3
460
(M
0.0
18.5
12.7
36.3
460
(NW)
0.0
18.5
12.7
28.2
357
(NW)
0.0
18.5
4.0
28.2
113
Items shown with an asterisk(*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
•Glazing
Glazing
Glazing
Glazin
Glazing
rage I oial
Btu/hr
0
Orientation
Btu/hr
Shaded
Area
X
X
x
X
X
X
X
X
x
X
GLF
+
+
+
+
+
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
x
X
X
X
X
Page
GLF
=
=
=
=
=
=
=
=
=
=
Btu/hr
(�
0.0x
18.5+
4.0x
36.3=
145
(W)
0.0
18.5
12.7
36.3
460
(M
0.0
18.5
12.7
36.3
460
(NW)
0.0
18.5
12.7
28.2
357
(NW)
0.0
18.5
4.0
28.2
113
Total
1 535
Internal Gain
Btu/hr
Occupants
4
X Occupants X 230 Btuh/OCC. =
P
920
Equipment
1
X Dwelling Units X 1,600] Watts/sqft =
1,6001
Infiltration: 1.064 X 1.24 X 27.88 X
1 1472
Air Sensible CFM ELA DT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
11,354
Latent Gain
Btu/hr
Occu ants 0 X Occupants X 200 Btuh/oCC. =
800
Infiltration: a 771 X 1.24 X 27.88 X 0.00010 =
16
• Air Latent CFM ELA pw
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
816
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 13