Loading...
06-3509 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-itit 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:06=00003509 Property Address: 53748 _VIA DONA APN: 772-420-999-31 -298944- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 556526 Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Li cen Clas B %�� License No.: 799449 ate: O%Co ct»l - �� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or.offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: SANDY & NANCY BOSWORTH PO BOX 756 LA QUINTA, CA 92253 Contractor: JACOBS HOMES INC, PETER P.O. BOX 692 LA QUINTA, CA 92247 (760)777-9921 Lic. No.: 799449 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/02/07 MAR 15 2007 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. lteve and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 176983306 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Lab r Code rthwith ccoomm with those provisions. ata e:J�a�? A scan - G� l� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. . I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buildin tion, and hereby authorize representatives of this co ty to enter upon t above-mentioned grope tion pu ses. Si ture (Applicant or A t ' Application Number . . . . . 06-00003509 Permit . . . BUILDING PERMIT Per Additional desc . Extension ---------------------------------------------------------------------------- Permit Fee . . . . 2210.50 Plan Check Fee 1436.83 Issue Date MECHANICAL Valuation . . . . 556526 Expiration Date 8/29/07 Qty Unit Charge Per . . Extension Plan Check Fee BASE FEE 2039.50 57.00 3 nnnn ---------------------------------------------------------------------------- Tum RT.nr. 5nn;nnl-1,nnn,000 171.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Qty Unit Charge Per Permit Fee ' . . . . 283.32 Plan Check Fee 70.83 Issue Date . . . . FEE Valuation . . . . 0 Expiration Date 8/29/07 FURNACE <=100K 45.00 Qty Unit Charge Per EA MECH Extension 45.00 BASE FEE 15.00 6309.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 220.82 1625.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 32.50 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Issue Date Expiration Date 8/29/07 Plan Check Fee . . .00 Valuation . . . . 0 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 170.00 Plan Check Fee 42.50 Issue Date Valuation . . . . 0 Expiration Date 8/29/07 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 9.00 6.5000 EA MECH VENT FAN 58.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERAIIT Application Number . . . . . 06-00003509 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 378.00 Plan Check Fee 94.50 Issue Date Valuation . . . . 0 Expiration Date 8/29/07 Qty Unit Charge Per Extension BASE FEE 15.00 25.Of) A nnnn RA PTR FTXTTTRF 156.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 11.00 15.0000 EA PLB GAS METER 165.00 ---------------------------------------------------------------------------- Special Notes and Comments 6309 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH.February 23, 2007 12:20:05 PM JJOHNSON ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 891.31 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 143.68 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 55.65 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 3056.82 .00 .00 3056.82 Plan Check Total 1644.66 750.00 .00 894.66 Other Fee Total 5580.64 .00 .00 5580.64 Grand Total 10282.12 750.00 .00 9532.12 LQPERAIIT Building �' r Address J Address • � �� /per PO. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO 9A,1 t/ LA QUINTA, CALIFORNIA 92253 City Zip Tel. WA & Classif. I Lic # Arch., Engr., Designer Tel. Lic. # W f/ LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST OCC. GRP. A.P. Number 2 ;7 /2-!12 ^ W i Legal Description 4�,�I b%L� 'S/ Project Description ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from -Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Sq. Ft. Size j� o i NNo. Dw. Stories ries Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ A.• wnI Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Y Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS bt6 LI CITY OF LA QUINTA FINANCE DEPT. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from -Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE r Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: Project Address: Bosworth Bosworth 53-758 Via Dona Project Description: 1 SFD APN: 772-420-999-31 Type of Development: Residential This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL i -WO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Tract #: xx Commercial Date 03/12/07 Lot #'s: Industrial Total Square Feet of Building Area: 6309 sq. ft. Certification of Applicant/Owners: The person signing certifie at the ab ve information is correct and makes this statement under penalty of perjury and further represents that he/she is aut ed,�o s* on behalf of the owner/developer. Dated: 03/12/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing 17620 65995 Approval Prior to 1/1/87 Note: Number of Sq.Ft. 6309 sq. ft. Amount per Sq.Ft. 3.75 Amount Collected $23,658.75 Building Permit Application Completed: Yes/No By: . Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Maria L. Angulo, Facilities Secretary Signature: Not Subject to Fee Requirement Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day ?eriod to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days sta:-ts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good ciLuse, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Comoliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T IR F STRUCTURAL CONSULTANTS, INC. 75-153 lvfERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 E-MAIL RAYMOND@RFSTRUC"I-URAL.COM AUGUST 21, 2007 PETER JACOBS HOMES, INC. 5162.5 DESERT CLUB DRIVR, SUITE 205 LA QUINTA, CA. 92253 Re.: THE BOSWORTH RESIDENCE THE HIDEAWAY, LOT 4 3 ID 5-3--'�56 VIA DONNA 53 - 7 g O LA QUINTA, CA. FOLLOW-UP TO WALK THROUGH JOB NO.: 4544 DEAR PETER THIS LETTER ADVISES THAT WE HAVE OBSERVED THE STRUCTURAL REQUIREMENTS THAT ARE VISIBLE DURING CONSTRUCTION AT THE TIME OF OUR SITE VISIT. WE BELIEVE THAT THE AS -BUILT CONSTRUCTION AT THE TIME OF OUR VISIT IS IN GENERAL CONFORMANCE WITH OUR STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE BUILDING IN ITS FRAMED CONDITION PRIOR TO INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL AND ACCESSIBLE STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS: FOOTING SIZE AND REINFORCEMENT, TOP PLATE SPLICES, ROOF SHEATHING, AND ANY STRAPS ABOVE THE ROOF SHEATHING). RESPECTFULLY SUBMITTED �oQROFESS/0, M. Fqp `F2 0 No -57958 m * Exp. 06-30-0 s�9TF0 F/vi L CAL1F0��\P ZEYAD FAQIR, P TRISTATE LAW SURVEYORS & CIVIl ENGINEERS 78,120 CARE ESTAdo, SUITE 102, LA QUINTAL CALIFORNIA 92253 QL (760) 564.0271 (800) 363.6306 FAX (760) 564.0270 April 18, 2007 Mr. Jesse Jimenez CITY OF LA QUINTA 78-495 Calle Tampico La Quinta, CA 92253-1504 RE: Form Certification for The Hideaway Lot 31 D, Tract No. 29894-4 Dear Mr. Jimenez: This letter is to certify that a field survey was made of the existing form in the City of Ia Quinta. Lot 31 D of Tract No. 29894-4 was found to be in conformance with the approved Grading Plan and the lot lines are located accurately per the record map . The following are the results of our survey: LOT # PLAN GRADE MEAN ELEVATION 31D 1001.5 1001.52 If you have any questions, please do not hesitate to call. Sincerely, LAND SG9 LUKE R. Gt�� Luke R. Beverly V BEVERLY p LS. 8223 * No. eW (P. Ev. r �FCAI#' TITLE 24 REPORT Title 24 Report for: The Bosworth Residence (Guest House) Lot #15 @ The Hideaway La Quinta, CA 92253 Project Designer: Santa Maria Design Associates 75-153 Merle Drive, Suite B Palm Desert, CA 92211 (760) 568-3838 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION ; DATEJU BY. The EnergyPro computer program authorized by the California Energy Job Number: Date: 9/5/2006 i-"erfom7Rhe calculations summarized in this compliance report. This program has approval and for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. tnergyPro 4.1 by EnergySoft Job Number: User Number: 3665 1 I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 10 11 12 13 EnergyPro 4.1 by EnergySoft Job Number: User Number. 3665 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R T_he_B_os_wortb_Residence (Gi st HOUse) 650 ft2 91512QQ6 Project Title ft2 Raised Floor Area: Date _L.at_#15_@JheJAideaway I al- Uinta Slab on Grade Area: 650 ft2 Project Address 10.0 ft Building Permit # BREEZEAIa-M-VDl_TUN(NG Wait Wood_ 164 _QL69 R-21 R-0.0 (760) 346-0855 1 Documentation Author Telephone plan Check/Date _Ene��grero Compli ce Method 15 Climate Zone Field Check/Date TDV Energy Use Standard Proposed Compliance (kBtu/sf-yr) _ Design Design Margin Space Heating 2.13 1.51 0.62 Space Cooling 79.83 86.07 -6.25 Fans 12.09 15.73 -3.64 Domestic Hot Water 25.23 14.92 10.31 Pumas 0.00 0.00 0.00 Totals 119.28 118.23 1.05 Building Type: [X] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SE)135 deg Natural Gas Area: 169 ft 2 Avg. U: 0.49 Ratio: 26.0% Avg. SHGC: 0.38 Total Conditioned Floor Area: 650 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 650 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 Wait Wood_ 164 _QL69 R-21 R-0.0 Number of Stories: 1 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units 650 —6,500 1 nn OPAQUE SURFACES Insulation Act. Type_ Frame Area U -Fac. Cay. Cont. Azm. Tilt .Roof__ Wood_ 6.5.0_ _0-025_ R -IR X0.0 _345_ 0 Wall_ Wood_ _322 --0-06,9- —R-21 R-0.0 45 _90 Wall_ Wood_ ---1.6-6 —O_O6Il_ R_21 R-0 0 _12-5- gIl Wall__ Wood_ _3.3.9_ —0 062 R21 R-0 0 —225 A0 Wait Wood_ 164 _QL69 R-21 R-0.0 --- 3J-5- A Zone Type Cnnditioned— Gains Condition Y / N Status JA IV Reference Thermostat Vent Type Hgt. Area —Setback— --2 ala Location / Comments New _01A18 70NE #5 Nev 09-A6 ZONE #5 New 0.9_/ 6 ZONE 5 Nen_ 09-A6 ZONE #5 Ne3y 09-A6 ZONE #5 I EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:3 of 14 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Bosworth Residence (Guest House) 9/5/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1_ Window-Righ.t_(NE) 11-2 0.37() NFBC__0-30 -NERG 45 90 New P_e)la_Eixed ZONE #5 2 Window Right (NE) 11.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #5 3 Window Right (NE) 11.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #5 4 Window Front (SE) 24.0 0.370 NFRC 0.30 NFRC 135 90 New Pella Fixed ZONE #5 5 Window Front (SE) 40.0 0.770 116-A 0_59 116-6 135 90 New Double Metal Tinted(Swng ZONE #5 6 Window Front (SE) 24.0 0.370 NFRC 0_30 NFRC 135 pD�efault 90 New F'e�la Fixed _ ZONE #5 L_ Window Front ( 3.0 0.790 116-A 0_59 116-B 135 90 New DefaWt Double Metal ZONE #5 8 Window Front (SE) 3.0 0.790 116-A 0.59 116-B 135 90 New 5014 t PJOetal ZONE #5 .9- Window Left(SA 3.1 0.790 116-A 0_59 116-B 225 90 New etal ZONE #5 1D Winslow Le1L__(_S_YY) 3_1 0.3.7 NFRCQ34 NFRC 225 �Q N _ ��1�@ @®rable) ZONE #5 11 Window Rear _(NW) 3.1 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 12 Window Rear (N� 8.0 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 13 _Wirtdow Reac_(.NW) 16.5_ 0.37 NFBC_030 NFR , -315_ _,a NeW Pella Fixed ZONES 14 Window Rear (NW) 8.0 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window # Exterior Shade Type SHGC Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen _ 0.76 _ 2 Bug Screen _ 0.76 _ 3 Bug Screen - 0.76 4 Bug Screen _ 0.76 5 � Screen 0.76 6 Bug Screen 0.76 7Bug Screen 0.76 8_ Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 _ 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 100 None No Insulation 26-A1 New ZONE #5 Slab Perimeter _ _ 18 None No Insulation 26-A1 New ZONE #5 Run Initiation Time: 09/05/06 16.53.42 Runrode: 1157493222 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number: Page:4 of 14 Certificate Of Compliance: Residential (Part3 of 4) CF -IR The Bosworth Residence (Guest House) 9/5/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location _ Type Eff Type Eff Status Type HVAC -#5 _ _ _ Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -#5 Ducted Ducted Attic 6.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. A.O.Smith FGR -75 Large Gas No Pipe Insulation 1 76,000 75 New 0.72 0.00% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Control # HP Type In Plenum Outside Buried Add 1/2" Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Santa Maria Design Associates Address: 75-153 Merle Drive, Suite B Palm Desert, CA 92211 Telephone:.( 568-3838 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 0t,_ (signature) I Adate) (signature/stamp) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R The Bosworth Residence (Guest House) 9/5/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items squire special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies: based on the adequacy of the special justification and documentation submitted. Plan Field Che Roof "R-38 Roof" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the C=AR plan Field installation certificate. The HVAC System "HVAC -#5" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. IThe Cooling System "PSA2BD / PGCIRA (3 Ton) 13 SEER" includes credit for a 12.0 EER Condenser. A certified FERS rater must field verify the installation of the correct Condenser. L EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paoe:6 of 14 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions; Check or initial applicable boxes when completed or check N/A if rot ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent Ur -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent Ur -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, Flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and El El El CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1506): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ ❑X ❑ insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ o ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:7 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑x ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑X ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:8 of 14 Residential Kitchen Lighting Worksheet WS -5R The Bosworth Residence (Guest House) 9/5/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts _—._-- Yes No —. x = or Yes No x = or -. -- Yes No x = or Yes No x = or Yes No x = or Yes No x = — or Yes No x = or Yes No x = or —_ ---- -- --- — Yes No x = or Yes No x _ _ -- or - - — — --- Yes No x - - or _. Yes No x = or --------_..-- Yes No — x = or Yes No x = or __ -- Yes No x = or Yes No x = or _--- Yes No x = or — __ Yes No x = or Yes --No-H x = or Yes No I x = or Total A: 0 B: 0 COMPLIES IF A >_ B YES nX NO EnergyPro 4.1 by E User Number: 3665 Job Number: of 14 AC SYSTEM HEATING AND COOLING LOADS SUMMARY ECT NAME DATE _ The Bosworth Residence Guest House 9/5/2006 =M NAME FLOOR AREA HVAC -#5 Fin ENGINEERIN Number of ; 1 Output per System 43,0001 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Total Output (Btu h) 43,000 Output (Btuh/sgft) 66.2 tooling System Output per System 35,000 Total Output (Btuh) 35,000 i Total Output (Tons) 2.9 Total Output (Btuh/sgft) 53.8 Total Output (sgft/Ton) 222,9 1,620 Airflow (cfm/Ton) COIL COOLING PEAK COIL HTG. PEAK CFM Sensi I CFM I Sensible 687 13,424 2,033 443 1,143 49 13,865 0 1,934 1,620 0 0 49 1,944 2,217 0 0 1.9341 1,620 19,235 3,1761 19 321 Imir aystem HVAC EQUIPMENT SELECTION � CFS M per System 1,200 PSA2BD / PGC1 RA (3 Ton) 13 SEER 29,269 0 43,000 Airflow (cfm) _- _ 1,200 1.85 Airflow (cfm/sgft) ~ Airflow (cfm/Ton) 411.4 --- -- — Outside Air (%) Total Adjusted System Output 29,269 0 43,000 4.1 (Adjusted for Peak Design Conditions) 0.08 Outside Air (cfm/sgft) TIME OF SYSTEM PEAK Aug 2m Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 26.0 of 67.0 of 100.7 of 100.7 of Supply Air Ducts Outside Air O i 49 cfm gg 4 °F Heating Coil Supply Fan 1200 cfm ROOMS 68.7 of 70.0 of Return Air Ducts ' OGLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1111.0 / 77.6 of 75.0 / 60.9 of 52.1 / 51.0 of 52.1 / 51.0 of OSupply Air Ducts Outside Air 49 cfm Cooling Coil Supply Fan 53.6 / 51.7 of 1200 cfm ROOMS 47.8% R.H. 73.5!60.0 of 72.0 ! 59.4 of Return Air Ducts I EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 10 of 14 ROOM LOAD SUMMARY PROJECT NAME DATE The Bosworth Residence Guest House 9/5/2006 SYSTEM NAME FLOOR AREA HVAC -#5 650 EAK ZONE NAME ROOM NAME Mult. I CFM I SENSIBLEI LATENT I CFM I SENSIBLEI LATENT CFM SENSIBLE Guest House / Casita ZONE #5 G 1 687 13,424 2,033 687 13,424 2.03311 443 13.865 PAGE TOTAL TOTAL 1 687 13,424 2,033 443 13,865 1 687 13,424 2,033 443 13,865 EnergyPro By EnergySoft User Number: User Job Number: Page, 11 of 14 ROOM HEATING PEAK LOADS Project Title Date rcvvrrn rnivrmanon Vesicin conditions Room Name Guest House Time of Peak Jan 12 am Floor Area Casgg Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction 'T OF Btu/hr Area U -Value ,R-38 Roof_.. 'R-21 Wall Pella Fixed P-ella_Eixed- R-21 Wall _ P 1a Fixe_d___ _ . Default Double Metal Tinted Swn Dr P-ella-Fixed Default Double Metal Tinted(O erable Defau[LD.oub.te-Metal-TirLte-d.(-QpjacableI R-21 Wall Default Double Metal Tinted O e able 1PellaFixed___-._-._. _ tR-2-1Wall_----_..-__ P-ella-F-ixed --.._ Pella-F-ixed--__-.-_ Pel IaL Fixed Slab=On_Grade_ S.Iab-0n=Grade- - _ i Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: C. 11.200 Infiltration: 1.00 x 1.064 x 650 x 10.00 x 0.525 / 60] x 44 = 2=664. Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,865 �_ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 12 of 14 650.0 X X x X X X X X X x X X X x X X x X x X X x x x x x x X X x x X X x x x x x x 0.0250 X x X x X X X X X x X X X X X X x x X X x x x x x x x X x x x X x x X x X x X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 321.8 0.0690 _ 44 11.2_ 0.3700 44 11.0 0.3700 44 11.0 0.3700 44 166.0 0.0690 44 24.0 0.3700 44 40.0 0.7700 44 24.0 0,3700 44 3.0 0.7900 3.0 0.7900 44= 338.7 0.0690 44 3.1 0.7900 44 3.1 _. 0.3700 0.0690 44= 184.4 44= 3.1 0.3700 44 ..Q 0,3700 4.4= 16.5 0.3700 44= 8.0 0.3700 44 perimeter = 100.0 0.7300 44 perimeter =18,Q 0.7300 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: C. 11.200 Infiltration: 1.00 x 1.064 x 650 x 10.00 x 0.525 / 60] x 44 = 2=664. Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,865 �_ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 12 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title The Bosworth Residence Room Information Room Name: iFloor Area: Indoor Dry Bulb Temperature: Opaque Surfaces Date st House) 19/5/2006 Design Conditions Guest House / Casita Outdoor Dry Bulb Temperature: 1120F 650 sf Outdoor Web Bulb Temperature: 78o17 72 of Outdoor Daily Range: 340F Orientation Area X X X X X x x x x x x x U -Factor X X X X X x x x x x x x CLTD 1 N 650.0 0.0173 56.0 NE 321.8 166.0 0.0690 29.0 SE 0.0690 31.0 SW 338.7 0.0690 31.0 NW 184.4 0.0690 30.2 24.0X 25.4 0.0x 37.7+ 3.0X 51.3= 0.0x 37.7+ 3.0x 51.3= 0.0x 37.7+ 3.1x _. 0.0x 18.5+ 3.1xL _.- Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw (A7)_ _-_ FxdWdw M)- FxdWdw (A9)_..----- FxdWdw .UW SwngGlsDr FxMdw U _ LHorizSldr HorizSldr iJ _ HorizSldr FxdWdw (A2) Orientation (NE) (NE NE SE SE SE SE SE SW SW Page Total Shaded Unshaded Area GLF Area GLF Btu/hr - 630 644 355 725 385 0.0x x 18.5+ + 11.2x x; 28.2= = = _ _ 0.0X 18.5+ 11.0X 28.2= 0.0x 0.0x 18.5+ 11.0x 28.2= 18.5+ 24.0X 25.4 0.0x 37.3+ 40.0X 50.9= 0.0x 18.5+ 24.0X 25.4 0.0x 37.7+ 3.0X 51.3= 0.0x 37.7+ 3.0x 51.3= 0.0x 37.7+ 3.1x 51. 0.0x 18.5+ 3.1xL 25.4= Page Total 2.738 Btu/hr Internal Gain Btulhr Occupants _ 4 x Occupants X 230 Btuh/occ. = 920 :Equipment_._.___. _�� X Dwelling Units X 1 600 Watts/sgft = 1,600 Infiltration: -1..064 x 1.24 x 45.86 x E=J = 2 q22 Air Sensible CFM ELA /IT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13424 Latent Gain Btu/hr (Occupants _-_-� 0 x Occupants x 200 Btuh/occ. = 800 Infiltration:_.4_,7711 X 1.24 X 45.86 x F 0.00454 = 1 233 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,033 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 13 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY 'Project Title Date [The Bosworth Residence (Guest House) 9/5/2006 rcoom Intormation Desicin Conditions Room Name: Guest House / Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 650 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation �- Area x X X X X X x x x x x Y ---- Unshaded Area X XI x X X x x x X GLF 28.2 = = = = = _ = = = _— 0.0x 18.5+ 3.1X 88 0.0 18.5 8.0 28.2 225 0.0X 18.5+ 16.5 28.2= _ 465 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Orientation F? dMdw (A3) NW NW NW NW I U -Factor CLTD 1 x = x = x = X X x = X x = x = x = x = Page Total Btu/hr Shaded Area x x X x X x X x GLF + + + + + + + + Unshaded Area X XI x X X x x x X GLF 28.2 = = = = = _ = = = Btu/hr 0.0x 18.5+ 3.1X 88 0.0 18.5 8.0 28.2 225 0.0X 18.5+ 16.5 28.2= _ 465 0.0x 18.5+ 8.0x 28.2= 225 .... - -- -- Page Total L 1,004 Internal Gain Btu/hr )Occupants_ _ 4 x Occupants x 230 Btuh/occ. = 920 Equipment -� X Dwelling Units X 1,6001 Watts/sqft = 1.600 Infiltration: 1.064 x 1.24 x 4 .86 x Air Sensible CFM ELA /-\T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13424 Latent Gain__ Btu/hr Occupants___ _.-- - =L� X Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 45.86 x 0.00454 = 1233 Air latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,033 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: - - Page:14 of 14 _-] % IN TITLE 24 REPORT Title 24 Report for: The Bosworth Residence Lot #15 @ The Hideaway La Quinta, CA 92253 Project Designer: Santa Maria Design Associat( 75-153 Merle Drive, Suite B Palm Desert, CA 92211 (760) 568-3838 CITY OF LA (QUINTA BUILDING & SAFETY DEPT. FoPP.ROVED i Nsr UCTION Report Prepared By:L°fELAZ- CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 1/4/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number. User Number. 3665 r , I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 Form WS -5R Residential Kitchen Lighting 11 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 16 Room Heating Peak Loads 20 Room Cooling Peak Loads 24 j EnergyPro 4.1 by EnergySoft Job Number: User Number. 3665 1 Certificate Of Compliance : Residential Conditioned - (Part 1 of 4) CF -1 R Zhe_B_o_s__wacthBes.idence ___C.cndWoned- HYAC 3 1 /4/2027 Project Title -Lot 115_@She_ deaa--Qu.inta JiVgC44 474 x.265 -D,08- Date Project Address New 01_A18 ZQNE #2 .Roof Wall_ Wood- 132 0 0.69_R_21 R-0.0 45 90 Wan Wood- 224 n 069 _R-21 R -n Q -225- 90 Building Permit # BBEFZEAIB_COf1D1ZLQNllNCz N.ew 0196 70WF#9 New _0.9_26 7n14E #2 (760) 346-0855 Plan Chack/Date Documentation Author New _0.9=A6 ZQ.NF #2 Never _00=A6 ZOEF #2 Telephone N.e..w _0.9=A.6 Z0.:4F #3 New Il9=A6 ZQ_IE #3 _Enetg_yP�o Wall_ Wnnrl _9Q _p34 R_3n R_0-0 n 80 Boor Wood- 474 n 1 .Roof Woad_ 474 0 025 R-38 R-0.0 345 Wall_ Wood- 224 0 069 R_21 R-0-0__45_ 90 Wall_ Wood_ 167_ .0610=21_R=O-1 90 _Wall_ Wood_ _207_ 0.059 0210'`0_0__225_ SQ Wall_ Wood- 12Z 0 Dfi9 R21 R-0 0_ X1.5_-90 15 Field CFeck/Date Compliance Method New _01-A18 ZO`AE #4 Climate Zone INew 09--A6 ZONE #4 TDV Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.18 2.73 -0.55 Space Cooling 55.11 52.12 2.99 Fans 8.29 9.28 -1.00 Domestic Hot Water 4.27 3.27 1.00 Pumps 0.00 0.00 0.00 Totals 69.85 67.41 2.44 Percent better than Stan Building Type: [Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (NW) 315 deg Natural Gas Area: 995 ft2 Avg. U: 0.61 Ratio: 17.6% Avg. SHGC: 0.47 BUILDING ZONE INFORMATION Zone Name 3.5% Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Floor Area Volume Units Zone Type .HVA_ C=kl ______J_44.8 1.5,928 -0.26_ Conditioned - .H -V #2 930 10 230 0.16_ ___C.cndWoned- HYAC 3 2.807 33.5.84 0.50 Conditioned- JiVgC44 474 x.265 -D,08- _-Condi1ioned ❑ OPAQUE SURFACES Insulation Act. Type Frame Area Ll -Fac. Cay. Cont. Azm. Tilt Gains Condition Y / N Status JA IV Reference 5,659 ft2 n/a ft2 474 ft2 5,185 ft2 11.3 ft 1.00 2 Thermostat Vent 'ype Hgt. Area -Setback- 8 -n/a &_tback- 8 n/a Setback 8 n/a Se, back 8 n/a Location / Comments Roof Wood- 1 448 0 025 -38 R -n n 345 Q New _01=218 7nuF #1 Wall__ Wood- 63.0 -0 0.69 -21. _R-0 Q_ 45 -9Il Wall_ Wood_ -224 0 069_ R-21 _R=O..Q 136 90.[� [� N.ew _0.9--96 ZQNI`#1 New -0,9-- A-6- ZQNF #1 09 +6 ZQJWE #1 Wall- Wood- 40 n 069 R21 R-0 0 -3]5 _90 Wopd 930 0 025 R-319 R-0-0 345 - 0 IXNew [X ❑ New 01_A18 ZQNE #2 .Roof Wall_ Wood- 132 0 0.69_R_21 R-0.0 45 90 Wan Wood- 224 n 069 _R-21 R -n Q -225- 90 X IN ❑ El N.ew 0196 70WF#9 New _0.9_26 7n14E #2 Wall_ .Wood- Rn --G 69.021 R_n n _2ZQ__A.Q Wall_ WQoii_ 30.0 0.0.69 021--O.Q_-31.5____9Q .D.o9r None_ 21. 0..500. _None_ R-0.0 3,5- 9Q Roof Wood- ? 8QZ 0 025 _R38 R_n n-345_0 Wall Wood- 92 _0_W9_ 021 _R=O 0 4s -9.Q Wall- Wood- 26 0_0.69 X21 R-0_0 -90__9.0 Wall_ Wood- X6.8 0 069 021 R-0.0 135 go Wall_ W94d- 24 0 069 R_21 R-0.0 X80 �.0 Wall_ Wood- 5Il9_ 0069 R-21 R-Q.O -2255-9Q Wall_ Wood- 37- 0 069 R-91 R -n n 27n -gn 513 n n69 R_91 R_0_0 X15 IX [%Q D& [X [X_ D F H ❑ r_1 r_1HNPw New _0.9=A6 ZQ.NF #2 Never _00=A6 ZOEF #2 New .28--A4 ZQNE #2 New -01-AIR- ZO16IF #3 New .0.9-A6 ZQb1F #3 New -09--A6 ZQNE #3 New OP -A6 ZQ:JF #3 N.e..w _0.9=A.6 Z0.:4F #3 New Il9=A6 ZQ_IE #3 New -09 6 7n r- #3 ZONE #3 Wall_ Wnnrl _9Q _p34 R_3n R_0-0 n 80 Boor Wood- 474 n 1 .Roof Woad_ 474 0 025 R-38 R-0.0 345 Wall_ Wood- 224 0 069 R_21 R-0-0__45_ 90 Wall_ Wood_ 167_ .0610=21_R=O-1 90 _Wall_ Wood_ _207_ 0.059 0210'`0_0__225_ SQ Wall_ Wood- 12Z 0 Dfi9 R21 R-0 0_ X1.5_-90 lI ❑ [-0 X�New_ A [X b4ew L- Il9�6 21-A7 ZONE #4 New _01-A18 ZO`AE #4 New 0.9-A6 ZD --J F #4 _0.9=A6 ZQ&E #4 _ 'New D9=A6 ZQNE #4 INew 09--A6 ZONE #4 Run Initiation Time: 01/0410711:41:10 Run Code: 1167932470 _ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:3 of 28 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Bosworth Residence 10.0 1/4/2007 Project Title Date 7.0 FENESTRATION SURFACES 10 Bug Screen 0.76 10.0 True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ Wind.ow_Left_(NE) _8..0- _0290 11 S-A 0 59 _J1S=B 45_ _9.0_ Neenr DefaulWouble-Metal ZONE #1 2 Window Left (NE) 6.0 0.370 NFRC 0_30 NFRC 45 90 New 1%)I®cKQp@rable) ZONE #1 3 Window Left (NE) 20.0 0.390 NFRC 0_27 NFRC 45 90 New Pella Casement Vented ZONE #1 4 Window Left (NE) 20.0 0.390 NFRC 0_27 NFRC 45 90 New Pella Casement Vented ZONE #1 5 Window Rear (SE) 30.0 0.370 NFRC 0_30 NFRC 135 90 New Pella Fixed ZONE #1 6 Window Rear (SE) 24.0 0.770 116-A 0_59 116-B 135 90 New Default Double Metal Tinted(Swno ZONE #1 3 W'nulow Rear ($e) 30 0X70 NFRC 34 NFR 5_ �9 N.��la Eix�d ZONE #1 8 Window Rear (SE) 30.0 0.370 NFRC 0_30 NFRC 135 90 New Pella Fixed ZONE #1 9 Window Rear (-S-E) 30.0 0.37 NERC 0.30 NFRC 135 90 New Pella Fixed ZONE #1 _1.0 Window Rear (SE) 30.0 __Q31DLVFRC 0.30 NFRC 135 -9-0 N e Pella Fixed ZONE #1 11 Window Left (NE) 17.5 ' 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #2 12 Window Right (SW) 48.0 0.770 116-A 0_59 116-B 225 90 New Double Metal Tinted(Swnq ZONE #2 13 p -Default _Window Right (M -48.9_ _0.77 116-A _0M 116-B -22.5 -go NewI�[auu t��ltbJe MetaL 1w1ejXSwng ZONE #2 14 Window Right (SW) 3.1 0.370 NFRC 0_30 NFRC 225 90 New Bela Fixed ZONE #2 15 Window Front (NW) 3.1 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #2 16 Window Left (NE) 20.0 0.710 116-A 0_60 116-6 45 90 New Default Double Metal Tinted (Fixed? -ONE #3 17 Window Left (E) 22.5 0.370 NFRC 0_30 NFRC' 90 90 New Pella Fixed ZONE #3 18 Window Rear (SE) 120.0 0.770 116-A 0_59 116-B 135 90 New Default Double Metal Tinted (Sldq ZONE #3 19 Window Rear (_SE) 60.0 079NFRQ 0.30 JNFRQ _135 90 New P61la Fixed ZONE #3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. 10.0 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 _ 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 4 Bug Screen 0.76 Inside 5 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 Condition Location/ 6 Bug Screen 0.76 8.0 3.0 7.0 _0.1 7.0 7.0 JA IV Reference 7 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 8 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 9 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 10 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 11 Bug Screen 0.76 26-A1 New ZONE #2 Slab Perimeter 136 None No Insulation 12 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 13 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 14 Bug Screen 0.76 15 bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 10.0 12.0 10.0 0.1 10.0 10.0 19 Bug Screen 0.76 5.0 12.0 10.0 0.1 10.0 10.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Twe (sf) (in.) Car). Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Twe Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 80 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 22 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 39 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 24 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 136 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 01/04/07 11:41:10 Run Code: 1167932470 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page:4 of 28 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Bosworth Residence 1/4/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 20 -Nindoyr---tear fS.E.) X20-2 -0 77.0-116-1 ..59 51.6_B x.3.5_ -9D- N.ev-Qefau[LD uble-MetaLTiated /Slda ZONE #3 21 Window Rear (SE) 12.5 0.390 NFRC 0_27 NFRC 135 90 New P61a Casement Vented ZONE #3 22 Window Rear (S) 30.0 0.770 116-A 0_59 116-B 180 90 New Default Double Metal Tinted Swn ZONE #3 23 Window Right (SW) 6.0 0.370 NFRC 0_30 NFRC 225 90 New N la Fixed ZONE #3 24 Window Right (SW) 6.0 0.370 NFRC 0_30 NFRC 225 90 New Pella Fixed ZONE #3 25 Window Right (W) 3.1 0.370 NFRC 0_30 NFRC 270 90 New Pella Fixed ZONE #3 25 Window Front (ice) 96.0 0.77 11FrL�9 11� 31� 90 New pefault Double Metal Tinted (fig_ ZONE #3 27 Window Front (NW) 15.0 0.710 116-A 0.60 116-B 315 90 New Wault Double Metal Tinted (Fixed)ZONE #3 2$ Window Front (NW) 24.0 0.770 11 0.59 116_B 315 9Q New Default Double Metal Tinted(Swng ZONE #3 29 Window Left (NE) 5.0 0.370 NFRC 0.30 NFRC 45 92 New P91a Fixed ZONE #4 30 Window Left (NE) 5.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #4 31 Window Right (SW) 4.0 0.370 NFRC 0_30 NFRC 225 90 New Pella Fixed ZONE #4 32. -Window Riaht /SW_) 22.E 0.77 116-A-OM116-B 325 _9.Q New DefaulLD-oubl"-elaLTided�Siig-ZONE #4 33 Window Front (NW) 5.0 0.370 NFRC 0_30 NFRC 315 90 New Bela Fixed ZONE #4 34 Window Front (NW) 24.0 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #4 35 Window Front (NW) 22.6 0.770 116-A 0_59 116-B 315 90 New Default Double Metal Tinted(Swng ZONE #4 36 Window Front (NW) 24.0 0.370 NFRC 0_30 NFRC 315 90 New P la Fixed ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 10.0 12.0 10.0 0.1 10.0 10.0 21 Bug Screen 0.76 5.0 2.5 7.0 0.1 7.0 7.0 _ 22 Bug Screen 0.76 10.0 3.0 7.0 0.1 7.0 7.0 _ 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 _ 28 Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 8.0 _ 29 Bug Screen 0.76 _ 30 Bug Screen 0.76 _ 31 Bug Screen 0.76 _ 32 Bug Screen 0.76 _ 33 Bug Screen 0.76 _ 34 Bug Screen 0.76 _ 35 Bug Screen 0.76 36 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 55 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 01/04/07 11:41:10 Run Code: 1167932470 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page:5 of 28 Certificate Of Compliance : Residential (Par 3 of 4) CF -1 R The Bosworth Residence 1/4/2007 Project Title Date HVAC SYSTEMS HVAC DISTRIBUTION Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC -#2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC -#3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER rJew Setback HVAC DISTRIBUTION WATER HEATING SYSTEMS Ratedl Tank Energy Duct Duct Cor4tion Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -#1 Ducted Ducted Attic 6.0 New No HVAC -#2 Ducted Ducted Attic 6.0 New No HVAC -#3 Ducted Ducted Attic 6.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. A.O.Smith FGR -75 Large Gas No Pipe Insulation 1 76,000 75 New 0.72 0.00% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insu3ation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of :he California Code of Regulations,'and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, Lisulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Santa Maria Design Associates Address: 75-153 Merle Drive, Suite B Palm Desert, CA 92211 Telephone: (760) 568-3838 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 O7 (signature) (date) (signature/stamp) i EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page:6 of 28 i Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R The Bosworth Residence 1/4/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location HVAC -#4 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 6.0 New No WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations,- and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Santa Maria Design Associates Address: 75-153 Merle Drive, Suite B Palm Desert, CA 92211 Telephone: _(760) 568-3838 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 i7 (signature) A o(date) (signature/stamp) (date) EnerovPro 4.1 by EneravSoft User Number: 3665 Job Number: Paqe: 7 of 28 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R The Bosworth Residence 1/4/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement anpnry dptorminps the adpnuacv of the iustification. and may refect a buildino or desion that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. ' HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Installation certificate. Plan Field The HVAC System "HVAC -#1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (5 Ton) 13 SEER" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -#2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (3 Ton) 13 SEER" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. IThe HVAC System "HVAC -#3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2131D / PGC1 RA (5 Ton) 13 SEER" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -#4" incorporates a HERS verified Refrigerant Charge test ora HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (2 Ton) 13 SEER" includes credit for a 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. i i EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page:8 of 28 Mandatory Measures Summary: Residential (Page ? of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa:h used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if riot applicable. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ a #§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ i§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(0: Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures ❑ ❑ ❑ ❑ a ❑ ❑ o ❑ ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑X ❑ ❑ o ❑ ❑ ❑X ❑ § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i):. Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ ❑X ❑ insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ ❑X ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ Q ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number: Page:9 of 28 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑x ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ © ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Q ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in, bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) ceded to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ controlled by an occupant sensor that complies with Section f19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page:10 of 28 Residential Kitchen Lighting Worksheet . WS -5R The Bosworth Residence 1/4/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 2 ft Fluorescent T8 Elec Yes X No 22.0 x 5 = 110 or (1) 26w Compact Fluorescent Triple 4 Pin Yes X1 No 37.0 x 8 = 296 or 50w Low Voltage Halogen Yes No X 55.0 x 3 = or 165 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 406 B: 165 COMPLIES IF A >_ B YES ® NO ❑ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 11 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY - 1PROJECT NAME DATE i The Bosworth Residence 1/4/2007 SYSTEM NAME FLOOR AREA HVAC -#1 1,448 NGINEERING CHECKS I� Number of Systems 1 Heating System Output per System 86,000 Total Outnut IBtuhl 86,000 Output (Btuh/sgft) 59.4 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 40.1 Total Output (sgft/Ton) 299.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.38 Airflow (cfmrron) 413.8 Outside Air (%) 5.4 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM 1S.nsiblel Latent CFMSensible 26,697 6,578 PSA2BD / PGC1RA (5 Ton) 13 SEER 48,766 0 Total Adjusted System Output 8 766 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26.0 of 66.7 of Outside Air 109 cfm 69.1 of 111.0 / 77.6 of I Outside Air 109 cfm 73.1/60.0 of 107.10F Heating Coil Supply Fan 2000 cfm 28,012 86,000 86,000 Jan 12 am 107.1 of -30 Supply Air Ducts 106.2 of ROOMS 70.0 of k Return Air Ducts �1 res at Time of Cooli 75.2/61.2OF = 52.3/51.2OF Cooling Coil 52.3 / 51.2 of -)o Supply Air Ducts Supply Fan 53.4 /51.6 of 2000 cfm 48.6% R.H. ROOMS 72.0 159.6 OF Return Air Ducts < I EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 12 of 28 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY . PROJECT NAME DATE The Bosworth Residence 1/4/2007 SYSTEM NAME FLOOR AREA HVAC -#2 930 ENGINEERING CHECKS SYSTEM LOAD !Number of Systems 1 COIL COOLING PEAK I I CFM I Sensible LF -tent Total Room Loads 833 15,726 2,919 Return Vented Lighting 0 Return Air Ducts 2,117 Return Fan o Ventilation 70 2,770 1,532 Supply Fan 0 Supply Air Ducts 2,117 TOTAL SYSTEM LOAD 22,73. 4,45. COIL HTG. PEAK I CFM I Sensible 455 13,9741 1,470 0 70 3,18 0 1,470 20,095 lHeating System Output per System 43,000 Total Output (Btuh) 43,000 Output (Btuh/sqft) 46.2 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 37.6 Total Output (sgft/Ton) 318.9 Air System HVAC EQUIPMENT SELECTION CFM per System 1,200 PSA2BD / PGC1 RA (3 Ton) 13 SEER Total AdjustedSystemOutput (Adjusted teDes9Conditions) TIME OF SYSTEM PEAK 29,667 0 29,667 F Aug 2 pm 43,000 43,000 Jan 12 am Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.29 Airflow (cfm/Ton) 411.4 Outside Air (%) 5.8 Outside Air (cfm/sqft) 0.08 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 66.4 OF 100.00F 100.0 OF 01 —O, Outside Air 70 cfm Heating Coil Supply Fan 1200 cfm 68.8 of Return Air Ducts Supply Air Ducts 98.9 of ROOMS 70.0 OF OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak i 1111.0/77.6 OF Outside Air 70 cfm 73.7 / 60.5 of 75.8/61.7 OF 52.6/51.5 OF 52,6 151,5 OF O St.pply Air Ducts 6 Cooling Coil Supply Fan 54.3 / 52.2 of 1200 cfm49.6% R.H. ROOMS 72.0 / 59.9 of I Return Air Ducts EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 13 of 28 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Bosworth Residence 1/4/200 NAME FLOOR AREA (SYSTEM HVAC -#3 2,807 Output per System 58,000 Total Output (Btuh) 116,000 Total Output (Tons) 9.7 Total Output (Btuh/sgft) 41.3 Total Output (sgft/Ton) 290.4 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sgft) 1.43 Airflow (cfm/Ton) 413.8 Outside Air (%) 5.3 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,199 42,678 7,196 1,155 44,220 0 5,745 4,652 0 0 2111 8,431 4,820 211 9,613 0 5,745 0 4,652 62,599 12,017 63 138 PSA2BD / PGC1 RA (5 Ton) 13 SEER 97,564 0 172,000 Total Adjusted System Outputg7 5r�—� 172,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0°F 66.6°F 107.10F 107.1 OF O Supply Air Ducts Outside Air 211 cfm 106.0 OF Heating Coil Supply Fan 4000 cfm ROOMS 70.0 OF 68.9 OF k Return Air Ducts `i ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 1111.0/77.6°F 75.3/61.3°F 52.4/51.3°F 52.4/51.3°F eee0 I Supply Air Ducts I Outside Air ,Y.... = 211 cfm Cooling Coil Supply Fan 53.8/51.9 OF 4000 cfm 48.5% R.H. ROOMS 73.3/60.1 of 72.0/59.6°F Return Air Ducts ! i I i EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 14 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Bosworth Residence 1/4/2007 SYSTEM NAME FLOOR AREA HVAC -#4 474 ENGINEERING CHECKS SYSTEM LOAD I 1Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK I CFM I Sensible Latent I CFM I Sensible Total Room Loads 1 571, 11,221 1,880 2061 8,390 Return Vented Lighting o Return Air Ducts 1,510 883 Return Fan 0 0 Ventilation 36 1,408 82836 1,625 Supply Fan 0 0 Supply Air Ducts 1,510 883 TOTAL SYSTEM LOAD 15,649 2,708 11 781 Heating System Output per System 1 36,0001 Total Output (Btuh) I 36,000 Output (Btuh/sgft) 75.9 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 50.6 Total Output (sgftrron) 237.0 Air System HVAC EQUIPMENT SELECTION CFM per System 800 PSA2BD / PGC1 RA (2 Ton) 13 SEER 20,138 0 36,000 Airflow (cfm) 800 Total Adjusted System Output 0,138 0 36,000 Airflow (cfm/sqft) I 1.69 Airflow (cfmrron) 400.0 Outside Air (%) 4.4 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 67.10F 109.3 OF 109.3°F Supply Air Ducts Outside Air w 36 cfm 108.3 of Heating Coil Supply Fan 800 cfm ROOMS 70.0 of 69.0 of Return Air Ducts OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1 111.0/77.6OF 75.4/61.10F 51.8/50.7OF 51.8/50.7°F O Supply Air Ducts Outside Air I 36 cfm Cooling Coil Supply Fan 53.5 / 51.4 of 800 cfm ROOMS 48.10% R.H. 73.8 / 60.1 of 72.0 / 59.5 OF I Rcfiirn Air r)iirfe ! EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 15 of 28 IROOM LOAD SUMMARY I PROJECT NAME The Bosworth Residence DATE 1/4/2007 SYSTEM NAME HVAC -#1 FLOOR AREA 1,448 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite / Den 1 887 17,586 4,100 887 17,586 4,100 494 19,031 PAGE TOTAL 887 17,586 4,100 494 19,031 TOTAL 1 887 17,586 4,100 494 19,031 EnergyPro By EnergySoft User Number. User Job Number: Page: 16 of 28 ROOM LOAD SUMMARY PROJECT NAME The Bosworth Residence DATE 1/4/2007 SYSTEM NAME HVAC -#2 FLOOR AREA 930 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #2 Media Room / Laundry / Hal 1 833 15,726 2,919 833 15,726 2,919 455 13,974 PAGE TOTAL 1 833 15,726 2,919 455 13,974 TOTAL 1 833 15,726 2,919 455 13,974 EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 28 ROOM LOAD SUMMARY PROJECT NAME The Bosworth Residence DATE 1/4/2007 SYSTEM NAME HVAC -#3 FLOOR AREA 2,807 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Living Area 1 2,199 42,678 7,196 2,199 42,678 7,196 1,155 44,220 PAGE TOTAL 1 2,196 42,678 7,196 1,155 44,220 TOTAL 1 2,199 42,678 7,196 1,155 44,220 EnergyPro By EnergySoft User Number. User Job Number: Page: 18 of 28 ROOM LOAD SUMMARY PROJECT NAME The Bosworth Residence DATE 1/4/2007 SYSTEM NAME HVAC -#4 FLOOR AREA 474 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #4 Guest Suite (Upstairs) 1 571 11,221 1,880 571 11,221 1,880 206 8,390 PAGE TOTAL 1 571 11,221 1,880]F ---20T6 8,390 TOTAL 571 11,221 1,880 206 8,390 EnergyPro By EnergySoft User Number: User Job Number. Page:19 of 28 ROOM HEATING PEAK LOADS I Project Title Date The Bosworth Residence 11/4/2007 Room Information Design Conditions Room Name Master Suite / Den Time of Peak Jan 12 am Floor Area 1,448 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value LT of Btu/hr 1,448.0 x 0.0250 x 44 = 1,593 630.0 x 0.0690 X 44 = 1,913 8.0 x 0.7900 X 44 = 278 6.0 X 0.3700 X 44 = 98 20.0 X 0.3900 X 44 = 343 20.0 X 0.3900 X 44 = 343 224.0 x 0.0690 X 44 = 680 30.0 X 0.3700 x 44 = 488 24.0 x 0,7700 x 44 = 813 30.0 X 0.3700 X = 488 30.0 x 0.3700 x 44= 30.0 X 0.3700 x 44 = 488 30.0 x 0.3700 x 44 = 488 40.0 X 0.0690 X 44= 121 perimeter= 80.0 X 0.7300 X 44 2570 perimeter = 22.0 x 0.7300 x 44 = 707 x x = x X x x = X x x x = x x x X = X x X x x X x X X x = x x X X X X X X = x x X x = X X X x x X x X = x x Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: L---, 1,9011 Infiltration: F 1.00 x 1.064 x 1 448 x 11.00 x 0.574 / 60] x L1 = 7.1311 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,031 I EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 20 of 28 I ROOM HEATING PEAK LOADS Project Title Date The Bosworth Residence 1/4/2007 Room Information Design Conditions Room Name Media Room / Time of Peak Jan 12 am V10" Outdoor Laundry/H Floor Area 9Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9 394 Infiltration: [ 1.00 1 X01 641 X 930 X 11.00 X 0.574 / 60] X 4 580 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,974 j EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 21 of 28 i 930.0 x x x x X X x X x x x x X X X X x X X X X x X X X X X X X X X X X X X X X X X 0.0250 x X X x X x x x x X x X x x X X X x X X X X X X X X X x X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = 132.5 0.0690 44 17.5 0.3700 44 223.9 0.0690 44 48.0 0.7700 44 48.0 0.7700 44 3.1 0.3700 44 80.0 0.0690 44 3005_ 0.0690 44 3.1 0.3700 21.4 0.5000 44 perimeter = 39.0 0.7300 44 perimeter = 24.0 0.7300 44 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9 394 Infiltration: [ 1.00 1 X01 641 X 930 X 11.00 X 0.574 / 60] X 4 580 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,974 j EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 21 of 28 i ROOM HEATING PEAK LOADS Project Title Date The Bosworth Residence 11/4/2007 Room Information Design Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 2,807 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�'T of Btu/hr 2,807.0 92.0 20.0 25.5 22.5 467.5 120.0 60.0 120.0 12.5 24.0 30.0 509.0 6.0 6.0 36.9 .1 513.0 96.0 15.0 4 perimeter = 136.0 perimeter = 55.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration: C 1.001X 1.064 x 2 807 x 12.00 x 1 0.526 / 60J x Schedule Jr Sensible Area Ceiling Height ACH Fraction Page Total 44 1T 3,088 279 625 77 366 1,419 4,066 977 4,066 214 73 1,016 1,545 98 QR 112 51 1,557 3,252 469 81.,11 4.368 1,767 30,397 13,823 TOTAL HOURLY HEAT LOSS FOR ROOM 44,220 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 22 of 28 I ROOM HEATING PEAK LOADS Project Title Date The Bosworth Residence 1 /4/2007 Room Information Design Conditions Room Name Guest Suite! Time of Peak Jan 12 am (Upstai ; Floor Area 41 , Outdoor Dry Bulb Temperature 260F ilndoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT OF Btulhr R-30 Floor F.30.2x.16 474.0 x 0.03401 X 44 = 709 R-38 Roof 474.0 X 0.02501 x 44 = 521 ♦�1224.0 X 0.0690 X 44 = 680 Pella Fixed 5.0 X 0.3700 X 44 = 81 Rella-Fj Pri 5.0 X 0.3700 x 44 = 81 R-21 Wall 167.0 X 0.0690 x 44 = 507 R-21 Wall 207.4 x 0.0690 x 44 = 630 Pella Fixed 4.0 x 0.3700 X 44 = 65 D.efaulLD.ouble-MetaLTinted(S.w. 2-6 x 0.7700 x 44 = 766 R-21 Wall 127.4 x 0.0690 x = 387 P-ella-Fixed 5.0 x 0.3700 X 44=81 Pella Fixed 24.0 x 0.3700 x 44 = 391 Default Double Metal Tinted Swn Dr 22.6 x 0.7700 X 44 = 766 Pella Fixed 24.0 x 0.3700 x 44= 391 x X X X = X X X x X X = x X X X X X X x X X = X X X X X X x X = X X X X X X X X X X = X x = X x = X x = x X = x x X x Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 6 056 Infiltration: [ 1.00 x 1.064 x 474 x 9.00 x 0.701 /6 0� x 0 = 2 334 Schedule Air Sensible Area Ceiling Height ACH 4T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,390 j EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 23 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Bosworth Residence 11/4/2007 Room Information Design Conditions Room Name: Master Suite / Den Outdoor Dry Bulb Temperature: 112°F Floor Area: 1,448 sf Outdoor Web Bulb Temperature: 78°F Indoor Dry Bulb Temperature: 72°F Outdoor Daily Range: 340F e burraces R-21 Orientation Area X X X X x x x X X X X X U -Factor x X X X x X X X X X X X CLTD 1 = = = = = = = = N) 1,448.0 0.0173 56.0 NE 630.0 0.0690 29.0 SE 224.0 0.0690 31.0 NW 40.0 0.0690 30.2 17.8+ 20.0X SE 30.0x 18.5+ 0.0X SE 24.0X 37.3+ 0.0x SE 30.0X 18.5+ O.OX SE 30.0X 18.5+ O.Ox SE 30.0x 18.5+ O.Ox SE 30.0X18.5+ O.OX Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration u'Tiii�i�CR9 IFxdWdw (19) 1 Nage I otal Orientation Shaded Area X GLF + Unshaded Area GLF 56.7= 28.2= 26.5= 26.5= 25.4= 50.9= 25.4= 25.4= 25. 25.4= x Page Total _ NE 0.0x 37.7+ 8.0x NE 0.0x 18.5+ 6.0X NE 0.0x 17.8+ 20.0X NE 0.0x 17.8+ 20.0X SE 30.0x 18.5+ 0.0X SE 24.0X 37.3+ 0.0x SE 30.0X 18.5+ O.OX SE 30.0X 18.5+ O.Ox SE 30.0x 18.5+ O.Ox SE 30.0X18.5+ O.OX Btu/hr 1,403 1,261 479 83 3 226 Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants x 230 Btuh/occ. = 920 E ui ment* x Dwelling Units X 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 x 1.49 x 102.17 x 40 = 6,4A1 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,5861 Latent Gain Btu/hr Occupants 4 x Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.49 x 102.17 x 0.00454 = 3,3001 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,100 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 24 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title idence Room Information Design Conditions I Room Name: Media Room / Laundry / Hall Outdoor Dry Bulb Temperature: 1120F Floor Area: 930 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-38 Roof N 930.0 X 0.0173 X 77.0 = 1,239 R-21 Wall NE 132.5 X 0.0690 X 34.0 = 311 R-21 Wall SW 223.9 X 0.0690 X 52.0 = 803 R-21 Wall W 80.0 X 0.0690 X 55.0 = 304 R-21 Wall NW 300.5 X 0.0690 X 48.1 = 997 Solid Wood Door NW 21.4 X 0.5000 x 54.0 = 578 x x = x x = x x = x x = x x = x x = Page Total 4 231 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr FxdWdw C U 0.0 x 22.2 + 17.5 x 33.4 = 584 Swn GIsDr7 SW 48.0 X 44.6 + 0.0 X 120.5 = 2,140 Swn GIsDr 6 SW 48.0 X 44.6 + 0.0 x 120.5 = 2,140 FxdWdw U SW 0.0 x 22.2 + 3.1 x 60.8 = 191 FxdWdw A NW 0.0 X 22.2 + 3.1 X1 49.7 = 156 x + x x + x X + X x + x x+ x = X,::::::] + x Page Total 5 212 Internal Gain Btu/hr Occupants 4 X Occupants x 230 Btuh/occ. = 920 LcLuipmenf ( 1 x Dwelling Units X 1,2001 Wafts/sgft = 1 1 200 Infiltration: 1.064 x 1.49 x 65.62 x 40 = 4163 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15726 Latent Gain �� Occupants I_ 4I x Occupants x 1 2001 Btuh/oCC. _ Btu/hr 8001 Infiltration: 4,771 x 1.491 x 65.62 x 0.00454 = 2,11 q Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,919 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 25 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title IDate The Bosworth Residence ;1/4/2007 Room Information Desicin Conditions _ Room Name: Living Area Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,807 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces R-38 Roof IR -21 Wall I R-21 Wall R-21 Wall 1R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation Area x x X X x x X X x X X x U -Factor X X X X X X x X x X X x CILTD 1 = = = = = = = = = = = N 2,807.0 0.0173 56.0 NE 92.01 0.0690 29.0 18.5+ 25.5 0.0690 33.0 SE 467.5 0.0690 31.0 S 24.0 0.0690 26.0 SW 509.0 0.0690 31.0 (W) 36.9 0.0690 33.0 (NW) 513.0 0.0690 30.2 18.5+ 6.0X SW 0.0x 18.5+ 6.0X 0.0X 18.5+ :::1x(w) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw IFxdWdw F'age I Dial Orientation Shaded Area x x X x GLF + + + + Unshaded Area GLF xi 55.8 36.3= x 50.9 25.4= 50.9= X 24.0 37.4= 25.4= 25. X Page Total = = = _ NE 0.0 36.5 20.0 E 0.0x 18.5+ 22.5x SE 120.0 37.3 0.0 SE 60.0X 18.5+ 0.0x SE 120.0X 37.3+ 0.0X SE 12.5 17.8 0.0 S 30.0X 37.3+ 0.0x SW 0.0x 18.5+ 6.0X SW 0.0x 18.5+ 6.0X 0.0X 18.5+ :::1x(w) Btulhr Btu/hr Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 P P E ui menY 1 X Dwelling Units X 1,6001 Watts/sqft = 1,600 Infiltration: 1.064 x 1.49 x 198.06 x 40 = 12 567 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,678 Latent Gain 1[ 41 Btu/hr _Occupants I 41 x Occupants x 1 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.49 x 198.06 x I 6,19d Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7,196 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page: 26 of 28 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title The Bosworth Residence Room Information Room Name: Floor Area: Indoor Dry Bulb Temperature: Opaque Surfaces Design Conditions Living Area Outdoor Dry Bulb Temperature: 2,807 sf Outdoor Web Bulb Temperature: 72 of Outdoor Daily Range: Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration U -Factor x x x x x GLF x x GLF x 56.3 X 55.8 x 56.3 X, x X X x x X x x x (NW) x x 96.0 x x 0.0 x x 836 x x 37.3 x x x x x x x CLTD 1 Page Total 112"17 780F 340F Btulhr Orientation Shaded Area x x x X x X x x x x X GLF + + + + + + + + + + + Unshaded Area GLF x 56.3 X 55.8 x 56.3 X, x X X x x X x = = = _ = = = Btulhr (NW) 0.0 37.3 96.0 5,402 NW 0.0 36.5 15.0 836 NW 0.0 37.3 24.0 1,350 Page Total 7 588 Internal Gain Btulhr Occupants 4 X Occupants x 230 Btuh/occ. = 920 !Equipment' x Dwelling Units x 1,600 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.49 x 198.06 x 12 567 Air Sensible CFM ELA /^%T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,678 Latent Gain Btulhr !Occupants 77]F---41 x Occupants x 1 2001 Btuh/occ. = 800 Infiltration: 4,7711 x x 198.06 x I 0.00454 = 6,3961 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7,196 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 27 of 28 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Bosworth Residence 1 /4/2007 Room Information Desicin Conditions Room Name: Guest Suite (Upstairs) Outdoor Dry Bulb Temperature: 112°F Floor Area: 474 sf Outdoor Web Bulb Temperature: 78°F Indoor Dry Bulb Temperature: 72 °F Outdoor Daily Range: 340F Opaque Surfaces Wall Wall Orientation Area X X X X X X x x x x x x U -Factor X X x X X X x X x x x x CLTD 1 Unshaded Area 474.0 0.0340 19.0 N 474.0 0.0173 56.0 NE 224.0 0.0690 29.0 SE 167.0 0.0690 31.0 SW 207.4 0.0690 31.0 (NW) 127.4 0.0690 30.2 0.0 37.3 22.6 50.9 1,150 NW 0.0x 18.5+ 5.0X 28.2= 141 (NW) 0.0 18.5 24.0 28.2 676 (NW) 0.0 37.3 22.6 56.3 1,272 (� Items shown with an asterisk (-) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration I FxdWdw (A11) 1 Page Total Btu/hr 306 459 448 357 444 266 2 280 Orientation 1.49 x Shaded Area X x x x x x X GLF + + + + + + + Unshaded Area X x x x x x 1XI= GLF = = = = = = = Btu/hr NE 0.0x 18.5+ 5.0x 28.2= 141 NE 0.0x 18.5+ 5.0X 28.2= 141 SW 0.0x 18.5+ 4.0X 25.4 102 (SW) 0.0 37.3 22.6 50.9 1,150 NW 0.0x 18.5+ 5.0X 28.2= 141 (NW) 0.0 18.5 24.0 28.2 676 (NW) 0.0 37.3 22.6 56.3 1,272 (� 0.0 18.5 24.0 28.2 676 I Page Total 4 299 Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 P P E uipment 1 x Dwelling Units x 1,6001 Watts/sgft = 1 600 Infiltration: 1.064 x 1.49 x 33.45 x 40 = 2122 Air Sensible CFM ELA 1W TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,2211 Latent Gain ;� Occupants I 41 x Occupants X 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4,771 X 1.49 x 33.45 x 0.00454 = 1080 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,880 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 28 of 28 1 TITLE 24 REPORT Title 24 Report for: The Bosworth Residence (Guest House) Lot #15 @ The Hideaway La Quinta, CA 92253 Project Designer: Santa Maria Design Associates 75-153 Merle Drive, Suite B Palm Desert, CA 92211 (760) 568-3838 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 1/4/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: User Number: 3665 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 Room Heating Peak Loads 12 Room Cooling Peak Loads 13 EnergyPro 4.1 by EnergySoft Job Number: User Number: 3665 Certificate Of Compliance : Residential Single Family (Part 1 of 4) CF -1 R S13e-Bnswofth-Besi.i_en-ce_(G_u.e_stAlausE) 650 ft2 1 /4/2007 Project Title _Lot -#1 -5_@ -lin H.id.e.avAcay—.La_(Dui.nta ❑ Existing + Add/Alt Existing Floor Area: Date Project Address Building Front Orientation: (SE) 135 deg Building Permit # BREEZE -AIR COlVD1T1QN.ING ft2 (760) 346-0855 plan Check/Date Documentation Author Slab on Grade Area: Telephone ft2 _EnergyLco 15 Field Check/Date Compliance Method ft Climate Zone 169 ft 2 TDV Energy Use Standard Proposed Compliance 1.00 (kBtu/sf-yr) Design Design Margin SHGC: . 0.38 Space Heating 2.13 1.51 0.62 BUILDING ZONE INFORMATION Space Cooling 79.83 86.07 -6.25 Zone Name Fans 12.09 15.73 -3.64 Hgt. Domestic Hot water 25.23 14.92 10.31 F50 —6,500 Pumps 0.00 0.00 0.00 Totals 119.28 118.23 1.05 Part --ant hot -tar than Stanrlarrt: 0.9% Building Type: Single Family ❑ Addition Total Conditioned Floor Area: 650 ft2 (19-A6 74NF #5 -W 09-A6 70NF #5 New -0 - 6 ZQNF #5 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (SE) 135 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 650 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 169 ft 2 Avg. U: 0.49 Number of Dwelling Units: 1.00 Ratio: 26.0% Avg. SHGC: . 0.38 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .HVAC... -#5 F50 —6,500 1.00_ Conditioned— —Setback— —2 n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U: -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Rnnf— Wnnd R50 —0025 R-18 X00 —345 o Rall flood_ _322 0069 _R -91R-0.0 41 9Il -/.all Wood— 166 0069 R-21 R-0.0_ 135 —990 Y%Lall— Wood— _339 —0-069 _B_21 R -n o 925_ gn� [ X X A ❑New ❑N_e-yr ❑N 01=A1A 70NF #r, (19-A6 74NF #5 -W 09-A6 70NF #5 New -0 - 6 ZQNF #5 A(all_ aL qQd— 184 _0..06.9 R-21 R-0.0 315 g0 ❑Neer D9 -A6 7QNF #5 ❑❑ ❑❑ �I Run Initiation Time: 01/04/07 11:40:56 Run Code: 1167932456 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number: Page:3 of 14 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Bosworth Residence (Guest House) 1/4/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments J_ _W5ndow___@gh1___(.NE)112 -0.320 NERC -0_30 - EBC __A5_ _90_ New -Pella Fixed ZONF #5 2 Window Right (NE) 11.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #5 3 Window Right (NE) 11.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Fixed ZONE #5 4 Window Front (SE) 24.0 0.370 NFRC 0_30 NFRC 135 90 New Pella Fixed ZONE #5 5 Window Front (SE) 40.0 0.770 116-A 0i59 116-B 135 90 New Default Double Metal Tinted(Swng ZONE #5 6 Window Front (SE) 24.0 0.370 NFRC 0`30 NFRC 135 90 New ZONE #5 7 Window Front (SE) 3.0 0.790 116E 0�59 B 135 90 New Default Double Metal ZONE #5 8 Window Front (SE) 3.0 0.790 116-A 0.59 116-B 135 90 New t tW&t®I?J0etal _ ZONE #5 9 Window Lg�ft (SW)3.1 9.799 116A_QM 116iB 225 90Ne� ftNEMetal ZONE #5 _-0 Window Left (SW) 3.1 0.370 NFRC 0.30 NFRC 225 Q0 New �011q(q@@rable) ZONE #5 11 Window Rear (NW) 3.1 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 12 Window Rear (NW) 8.0 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 13 Window Rear (NW)16.0_ 0.37 NFRCJ)aO NFRC 315 90 New Pella Fixed ZONE #5 14 Window Rear (NW) 8.0 0.370 NFRC 0_30 NFRC 315 90 New Pella Fixed ZONE #5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 _ 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 _ 5 Bug Screen 0.76 _ 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14. Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 100 None No Insulation 26-A1 New ZONE #5 Slab Perimeter 18 None No Insulation 26-A1 New ZONE #5 Run Initiation Time: 01/04/07 11:40:56 Run Code: 1167932456 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:4 of 14 Certificate Of Compliance : Residential (Par: 3 of 4) CF -1 R The Bosworth Residence (Guest House) 1/4/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum condition Thermostat Location Type Eff Type Eff Status Type HVAC -#5 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Cordition Ducts Location Heating Cooling Location R -Value Stats Tested? HVAC -#5 Ducted Ducted Attic 6.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Ehergy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status o- RE 1 (%) Ext. A.O.Smith FGR -75 Large Gas No Pipe Insulation 1 76,000 75 New 0.72 0.00% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. RIPMARWR COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 ofthe California Code of Regulations, • and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ McFadden Title/Firm: Santa Maria Design Associates Title/Firm: BREEZE AIR CONDITIONING Address: 75-153 Merle Drive, Suite B Address: 75-145 ST. CHARLES PLAC= Palm Desert, CA 92211 PALM DESERT, CA 92211 Telephone: (760) 568-3838 Telephone: (760) 346-0855 Lic. #: q o7 (signature) (date) (signature) date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:5 of 14 1 Certificate Of Compliance : Residential (Par_ 4 of 4) CF -1 R The Bosworth Residence (Guest House) 1/4/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aoencv determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the idequacy of the special justification and documentation submitted. I Plan Field The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervisior of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R plan Field installation certificate. The HVAC System "HVAC -#5" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGCIRA (3 Ton) 13 SEER" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. l I I I ! EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page:6 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. Whe..i this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Building Envelope Measures ;§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturer's labeled R -Value: *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). {§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous buming gas pilot lights allowed. § 150(0: Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ IR ❑ ❑ ❑ ❑X ❑ ❑ In X permeance rate no greater than 2.0 pernitinch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and ❑ ❑ ❑ include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ 0 ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ El (SHGC), and infiltration certification. Page:7 of 14 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): _Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank, insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ Q ❑ insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 intemal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ Q ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page:7 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ IR ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirement! of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ 2 ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑x ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(6. § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number. Page:8 of 14 Residential Kitchen Lighting Worksheet WS -5R The Bosworth Residence (Guest House) 1/4/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts U 26w Compact Fluorescent Triple 4 Pin Yes X No 37.0 x 1 = 37 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes I No x = or Yes No x = or YesNo x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 37 B: COMPLIES IF A >_ B YES ® NO ❑ i EneravPro 4.1 by EneravSoft User Number. 3665 Job Number: Paae:9 of 14 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY . (PROJECT NAME DATE The Bosworth Residence (Guest House) 1/4/2007 (SYSTEM NAME FLOOR AREA I HVAC -#5 650 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Latent Total Room Loads 687 13,4241 2,033 Return Vented Lighting 01 Return Air Ducts 1,934 Return Fan 0 Ventilation 49 1,944 1,143 Supply Fan 0 Supply Air Ducts 1,934 TOTAL SYSTEM LOAD 19,235F773 176 COIL HTG. PEAK CFM Sensible 443 13,865' 1 1,620 0 49 2,217 0 1,620 19 321 Heating System Output per System 43,000 Total Output (Btuh) 43,000 Output (Btuh/sgft) 66.21 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 53.8 Total Output (sgftrTon) 222.9 Air System HVAC EQUIPMENT SELECTION CFM per System 1,200 PSA213D / PGCIRA (3 Ton) 13 SEER 29,269 0 43,000 Airflow (cfm) 1,200 Total Adjusted System Output ` 19 269 0 43,000 Airflow (cfm/sgft) 1.85 Airflow (cfmrron) 411.4 Outside Air (%) 4 1 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions J-IEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.0 OF 100.70F 100.7 OF Outside Air 0 Supply Air Ducts 49 cfm 99.4 of Heating Coil Supply Fan 1200 cfm ROOMS 70.0 of 68.7 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1 1.01 77.6 of 75.0 / 60.9 of 52.1 / 51.0 of 52.1 / 51.0 of � i Outside Air Supply Air Ducts 49 cfm Olt ' Cooling Coil Supply Fan 1200 cfm 53.6 / 51.7 of I 472% R.H. I ROOMS 0 72.0 / 59.4 of I 73.5/60.0 F i I Rcfi irn Air fly irte 1 I i EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 10 of 14 j BROOM LOAD SUMMARY PROJECT NAME The Bosworth Residence Guest House DATE 1/4/2007 SYSTEM NAME HVAC -#5 FLOOR AREA 650 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE '-ATENT CFM SENSIBLE ZONE #5 Guest House / Casita 1 687 13,424 2,033 687 13,424 2,033 443 13,865 PAGE TOTAL 1 687 13,424 2,033 443 13,865 TOTAL 1 687 13,424 2,033 443 13,865 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 14 ROOM HEATING PEAK LOADS .Project Title iThe Bosworth Residence Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction Design Conditions Guest House/ Time of Peak Jan 12 am Ca9S50 Outdoor Dry Bulb Temperature 26°F 70 of Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 200 Infiltration: [ 1.001X 1.064 x 650 x 10.00 x 0.525 / 60] x &T = [7:::=2 664 Schedule Afr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,865 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number: Page: 12 of 14 Area X X x x x X X X X x X X x x X x x x X x x x x X x X X X x X X X X X X X X X X U -Value X x x x x X X x x x X x X x x x x X x x x x X X x x x X X X X X x X X X x X X Z�'T of = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 650.0 0.0250 44 715 321.8 0.0690 44 977 11.2 0.3700 44 182 11.0 0.3700 44 179 11.0 0.3700 44 179 166.0 0.0690 44 504 24.0 0.3700 44 391 40.0 0.7700 44 1,355 24.0 0.3700 44 391 3.0 0.7900 104 3.0 0.7900 44 104 338.7 0.0690 44 1,028 3.1 0.7900 44 109 3.1 0.3700 44= 51 184.4 0.0690 44=560 3.1 0.3700 44 51 44=110 16.5 0.3700 44=269 8.0 0.3700 44 130 erimeter = 100.0 0.7300 44 3,212 perimeter =18.0 0.7300 44=578 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 200 Infiltration: [ 1.001X 1.064 x 650 x 10.00 x 0.525 / 60] x &T = [7:::=2 664 Schedule Afr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,865 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number: Page: 12 of 14 A RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Bosworth Residence (Guest House) 1/4/2007 lRoom Information Design Conditions_ _ _ I Room Name: Guest House / Casita .Outdoor Dry Bulb Temperature: 112oF I Floor Area: 650 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces R-21 Wall Orientation Area N 650.0 NE 321.8 SE 166.0 (SW) 338.7 (NW) 184.4 x 0.0690 x x NE x x 11.0x x x 0.0x x x 28.2 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw 1 U -Factor x 0.0173 X x 0.0690 X x 0.0690 X x 0.0690 X x 0.0690 x x NE x x 11.0x x x 0.0x x x 28.2 x x 18.5+ x x SE x X 40.0 X CILTD 1 56.0 29.0 31.0 31.0 30.2 Page Total Orientation Shaded Area x x x x GLF + + + Unshaded Area X X I x GLF NE 0.0x 18.5+ 11.2x 28.2 NE 0.0x 18.5+ 11.0x 28.2 NE 0.0x 18.5+ 11.0x 28.2 SE 0.0x 18.5+ 24.0X 25.4 SE 0.0 37.3 40.0 50.9 SE 0.0x 18.5+ 24.0X 25.4 SE 0.0x 37.7+ 3.0X 51.3 SE 0.0x 37.7+ 3.0X 51.3 SW 0.0 37.7+ 3.1X 51. SW 0.0 18.5 3.1 25.4 Page Total Btu/hr 630 644 355 725 385 2,7381 Btu/hr Internal Gain Btu/hr Occupants 4 x Occupants x 230 Btuh/occ. = 920 �quipment 1 x Dwelling Units x 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.24 x 45.86 x CJ40 = 2422 Air Sensible CFM ELA AnT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,424 Latent Gain Btu/hr Occupants 4 x Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 45.86 x 0.00454 = 1233 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,033 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Pam 13 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Bosworth Residence (Guest House) 11/4/2007 Room Information Design Conditions Room Name: Guest House / Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 650 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F 5 u rtaces Orientation Area U -Factor CLTD 1 iiI Btu/hr x x x x x x X X x + + + + + + + Unshaded Area X X x X X X x Page GLF x Btu/hr X 0.0x = 3.1x 28.2= x NW x 18.5+ = 28.2= 225 x 0.0x x 16.5X = 465 NW x 18.5+ x 28.2= = x x = x x = x x = x x = x x = x x = x x 1 ooa = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw rage I otal Btulhr Orientation Btu/hr Shaded Area x x x x x X X GLF + + + + + + + Unshaded Area X X x X X X x Page GLF = = = = Btu/hr NW 0.0x 18.5+ 3.1x 28.2= 88 NW 0.0x 18.5+ 8.0X 28.2= 225 NW 0.0x 18.5+ 16.5X 28.2= 465 NW 0.0x 18.5+ 8.0X 28.2= 225 Total 1 ooa Internal Gain Btu/hr Occu ants P Di X Occupants X 230 Btuh/oCc. = 920 E ui menu X Dwelling Units x 1,6001 Watts/sgft = 1,600 Infiltration: 1.064 x 1.24 x 45.86 x = 2422 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13424 Latent Gain Btu/hr Occupants 0 x Occupants x 200 I Btuh/oCc. = 800 Infiltration: 4 771 x 1.24 x 45.86 x 0.00454 = 1,2331 Air Latent CFM ELA &W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,033 EnergyPro 4.1 by EnergySoft User Number 3665 Job Number: Page: 14 of 14 Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) :•23-1369 77-725 Enfield Lane, Suite 100, Palm Desert, CA 92211 (760) 772-3893 Fax (76g) 772-3895 September 5, 2006 Peter Jacobs Homes, Inc. P.O. Box 356 La Quinta, California 92253 Attn: Mr. Peter L. Jacobs Project: Hideaway — Lot 31 D Bosworth Residence La Quinta, California Subject: Geotechnical Update Project No. 544-06654 06-09-873 Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESS) dated April 11, 2001, File No. 08199-01, Report No. 04-04-716. Report of Testing and Observation during Rough Grading prepared by ESS dated August 28, 2002, File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading preparec. by Sladden Engineering Dated October 12, 2003, Project No. 544-2199 Report No. 03-13-647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed single family residence. The project site is identified as Lot 273 within the Hideaway Golf Club development in the City of La Quinta, Czlifornia. It is our understanding that the proposed residence will be a relatively lightweight wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included overexcavation of the nativE surface soils along with the placement of engineered fill material to construct the building pads. The regrading included processing the surface soils along with minor cuts and fills to construct the individual building pads. Some additional overexcavation was performed in arEas where the building envelopes were reconfigured. The site grading is summarized in the referenced Report of Observations and Testing during Rough Grading along with the compaction test -esults. September 5, 2006 -2- Project No. 544-06654 06-09-873 The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report remain applicable for the design and construction of the proposed residential structure foundations. Because the lot has been previously rough graded, the remedial grading required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and ` moisture conditioned prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Allowable Bearing Pressures: The allowable bearing pressures recommended in the grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. An allowable increase of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. Pertinent 1997 UBC Seismic Design parameters are summarized on the attached data sheet. If you have questions regarding this letter or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING �y No. C 45389 R Brett L. Anderson' W gyp. 9130106 Principal Engineer * �t S'T CIVIL ���P SER/lh FC Copies: 4/Peter Jacobs Homes, Inc. Sladden Engineering September 5, 2006 -3- Project No. 544-06654 06-09-873 1997 UNIFORM BUILDING CODE INFORMATION The International Conference of Building Officials 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the code that will be relevant to construction of the proposed structure are summarized below. Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 UBC) San Andreas 9.8 km A San Jacinto 26 km A Based on our field observations and understanding of local geologic conditions, die soil profile type judged applicable to this site is So, generally described as stiff or dense so -+l. The site is located within UBC .Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1957 code. Sladden Engineering Near -Source Near -Source Seismic Seismic Seismic Acceleration Velocity Coefficient Coefficient Source Factor, N. Factor, N� C. C� San Andreas 1.01 1.22 0.44 N. 0.64 N� San Jacinto 1.0 1.0 0.44 Na 0.64 N� Sladden Engineering