Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-5294 (SFD)
Box 1504 )5 CALLE TAMPICO UINTA, CALIFORNIA 92253 BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760').777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Application Number . . . . 04700005294 Date 10/26/04 Property Address . . . . . 53595 VIA DONA APN: 772 -420 -999 -38 -298S44 - Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENT3AL Application valuation 332277 Owner Contractor HIDEAWAY JOINT VENTURE II ALPHA OMEGA COMMUNICATIONS INC 42829 COOK ST STE 104 42829 COOK STREET PALM DESERT CA 92211 PALM DESERT CA 92260 (760) 568-1712, WCC: STATE FUND WC: 164166403 06/30/05 CSLB: 820066 a 05/31/05 CCC: B ------ Structure Information 3806 SQ FT.SFD ----- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=-0 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 849.00 PATIO SQ FTG 610.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- FIRST FLOOR SQ FTG 3806.00 Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee. 1455.00. Plan Check Fee 94.5.75 Issue Date . . . . Valuation . . . 332277 Expiration Date 4/21/05 Qty Unit Charge Per Extension BASE FEE 639.50 233.00 3.5000 THOU ---------------------------------------------------------------------------- BLDG 100,001-500,000 815.50 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 180.19 Plan Check Fee 41.33 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/21/05 Qty Unit Charge Per Extension BASE FEE 15.00 3806.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 133.21 P.O. BOX 1504 • VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: ,,- K Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is Trull force and effect. _ Cicerise Class -1 License No. lj 'Con Date f )Z / t7 tractor I �)rd f lee( . � C� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended.or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner. of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.& P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is �$sue�f My workers compensation insurance carrier nd Iiyy n"ur�b r are, EC—!T Carrier �StLtT (. /'LI/tiC f Policy Number1� C� = I certify that, in the performance of the -work for which_this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 'CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employeesfor any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to en r upon the above-mentioned pro erty for inspection purposes. .- DateLf—sigriature (Applicant or Agent): - — _J Page 2 Application Number . . . . . 04-00005294 Date 10/26/04 Qty Unit Charge Per Extension 849.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 16.98 1,.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ------------------=--------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/21/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 121.00 Plan Check Fee 25.75 Issue Date . . . . Valuation . . . 0 Expiration Date . . 4/21/05 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 7.00 6.5000 EA MECH VENT FAN '45.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 --------------'-------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc . . Permit Fee . . . . 235.50 Plan'Check Fee 58.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/21/05 Qty Unit Charge Per Extension BASE FEE 15:00 23.00 6.0000 EA PLB FIXTURE 138.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 3.00 6.0000 EA PLB ROOF DRAIN 18.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 .7500 EA PLB GAS PIPE >=5 7.50 1.00 ---------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 3806 SFD SQ.DOES NOT INCLUDE POOLS SPA Page 3 Application Number . . . . . 04-00005294 Date 10/26/04 ---------------------------------------------------------------------------- Special Notes and Comments BLK WALL OR DRIVE APP 10/19/04 3:34:41-P M GSHOWALTER sq. ft. is 3806 not 3462 for the sfd.10/ 21/04 9:29:16 AM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 250.15 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 94.58 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF,PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 30.00 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 2006.69 ------------------------------ .00 C0 2'006.69 Plan Check Total 1071.71 500.00 C0 571.71 Other Fee Total 2779.73 .00 C0 2779.73 Grand Total 5858.13 500.00 C0 5358.13 s FlNANCE "9S Vi,4 Aut A- Revenue P.O. BOX 1504 Building y1A 78-495 CALLE TAMPICO APPLICATION ONLY Address LA QUINTA, CALIFORNIA 92253 2 �� oar ,A' am,1/ Mailing VV V BUILDING: TYPE'CONST._� OCC.'jRP. �` I Address S A.P. Number �� 004 ✓ SIM2 � Legal Description (% j �✓5 Co a fornin Project Description } G 6 A dress _ . Zip 221 1 State Lic. City & Classif. Lic. # Designer, y, , � ydre21 Tel. vn'nel —7 (/� V/1i'YYl Zlp Sta Lic.t# / l��/I.f�c1 LICENSED CONTRACTOR'S I hereby affirm that I am licensed under provisions of Chap ncing wit ec Ion 7000) of Division 3 of the Business and Professions Code, and my license I effect. SIGNATURE DATE OWNER -BUILDER DECLARATION 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 1, asowner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projecfs with a contractors) licensed pursuant to the Contractor's License Law.) 1-1 1 am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company (7 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of lhp work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: It, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives sof this city to enter the above. mentioned property for inspection purposes. Signature of a0plicant —Date— Mailing ateMailing Address City, State, Zip Z_ Sq. Ft.., New ❑ Add ❑ Alter ❑ I No. Dw.r\ I t Units Repair ❑ Demolition ❑ PERMIT Al AMOUNT Plan Chk. Dep. QO Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading (i j -'`11 �r Driveway Enc. Infrastructure % _ v 1 nn I J4 t TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback fr•m Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DA INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING OVISION Coachella Valley Unified School District P.O. Box 847, Thermal, CA 92274. (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: CERTIFICATE AMGUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITI.3ATION AMOUNT: COMMAND. AMOUNT: nATF.- RFCF.IPT- CHF..'.K H. NITIAI9 INITIALS- CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence at Hideway Date October 27, 2004 Owner's Name: Hideaway Joint Venture II Phone Project Address: 53-595 Via Dona La Quinta, CA Project Descri tion: 1 SFD APN 772410-043 Tract Lots 38 Type of Development: I Residential XXX I Commercial I Industrial Total Square Feet of Building Are 13,875 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of,the ownerrdeveloper. October 27, 2004 SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR V% -ILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Note: Number of Sq.Ft. K2.6 Amount per Sq.Ft. Amount Collected .00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: I Elvira Mattson, Office Technician Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement r - NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-da3. period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good rause, as determined by the School iUiv—., ..- _ I WED OA 45 PM GordonRoss 6/25/04 NOTE: FAX N0, 7603417631 Spoke with Y,arissa at the Riverside Connry Assessor's office (909-486-7434). She said it is okay for multiple parcels of land to have the same APN. The transfer of title is done based. on legal desciiption NOT APN. P. 02/06 5 WED 04;48 PM GordonRoss -b2:46p Butch - Seal STATE OF California COUNTY OF Riverside FAX N0, 7603417631 303-794-4437 On _ March 8, 2004 before me,. K. Lafbv, Notary Public (Name, Title of Officer) personally appeared_ Joseph L. Arenson P. 04/06 P-6 personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to ms that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/herltheir signatures) on the instrument the person(s), or the entity upon behalf of which the parson(s) aced, executed the instrument. WITNESS my hand and official seal. (Signal a of No ry ubl c) K.laRB 0FFIriAI s� J Y COMM 61260797 V Jp Notary Publi Californy RIVERSIDE COUNTY _ MY ComMiWon Expires JUNE 24, 2004 (This area for notarial seal) un 1.1 04 5 WED 04;48 PM GordonRoss -b2:46p Butch - Seal STATE OF California COUNTY OF Riverside FAX N0, 7603417631 303-794-4437 On _ March 8, 2004 before me,. K. Lafbv, Notary Public (Name, Title of Officer) personally appeared_ Joseph L. Arenson P. 04/06 P-6 personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to ms that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/herltheir signatures) on the instrument the person(s), or the entity upon behalf of which the parson(s) aced, executed the instrument. WITNESS my hand and official seal. (Signal a of No ry ubl c) K.laRB 0FFIriAI s� J Y COMM 61260797 V Jp Notary Publi Californy RIVERSIDE COUNTY _ MY ComMiWon Expires JUNE 24, 2004 (This area for notarial seal) UN- un 11' 04 WED—O46 PM GordonRoss 02:46F Hutch Seal EXH BIT "A" Legal Description Parcel No. 1: FAX N0. 7603417631 303-794-4437 P. 05/06 p-7 Lot 38 (the "Lot') of Tract No. 29894.4, in the City of La Quinta, as shown by leap on file in Book 351, Pages 49 to 57, inclusive, of Maps, in the Office of the County Recorder of Riverside County, California. EXCEPTING AND RESERVING THEREFROKTO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745938, of Official Records of Riverside County, California (the "Official Records"); 2_ The Supplementary Declaration of Annexation of Property, recorded on March 4, 2004, as Instrument No. 2604-0151981, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Imt for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Gran --ea before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law.. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: 1. Non delinquent general, special and supplemental real property taxes and assessments. Ui Jun 11 04 WED -04419L -PM GordonRoss 02:4Sp Butch Seal FAX N0, 7603417631 303794-4437 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-4. P. 06/06 F. a Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The 11ideaway Owner, Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lor are set forth in the Declaration to which this Grant Deed is specifically and expressly made subect. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The. Hideaway Owners Asso'ation such powers and rights which are set forth in the Declaration defined above, on 3 fl 2004. SEAL OFFICE SUPPLY, TNC. By: Jo cal Its; Authorized Representative STATE OF 1�. — s.� �../ 9 ) ss. COUNTY OF i 14eZ5&�C ) On g, A-,/(.� , 2004, before me, the undersigned, a notary public in and for said State, personally appeared Jon Seal, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICLkL SEAL. [SEAL] Ignature My eorrmtission expires; �� D ...ftp CONNlE COMM, #1417229 N107AW WOUC. C4FOr941+ RMSW COURny tv—mlv cemngoon FKmesma 1.2M TITLE 24 REPORT QQ1 1 Title 24 Report for: 1' Lot #38 @The Hideaway Lot #38, Tract 29894-2 - The Hideaway La Quinta, CA 92253 ' Project Designer: Gordon Ross ' 42-829 Cook St., Suite #204 Palm Desert, CA 92211 '(760) 568-1712 I ! ' Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 ! C1 OF1 Job Number: BUILpINa & QUINTA SA "JPPROV DEPT. I FOR CONSTRUCT !� Date: SATE%J;l A BY 8/23/2004 . I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is ' authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoR Job Number: User Number: 3665 Certificate of Compliance: Residential (Part 1 of 2) CF -'l R Lot #38(cl__ The Hideaway 8/23/2004 Project Title Date ' Lot #38 Tract 29894-2 - The Hideaway La Quinta Location/Comments (attic, garage, typical, etc.) Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Cieck / Date Documentation Author Telephone R-21 Wall (W.21.2x6.16) ' Computer Performance 15 Field Cneck / Date Compliance Method (Package or Computer) Climate Zone Enforcament Agency Use Only Slab On Grade n/a n/a GENERAL INFORMATION Exposed Slab MR -0.0 Perimeter Insulation Total Conditioned Floor Area: 3,462 ft' Average Ceiling Height: 10.9 ft Total Conditioned Slab Area: 3.482 ft2 . Solid Wood Door ' Building Type: 0.387 (check one or more) 172.5 LXJ Single Family Detached ❑ Addition 0.38 ' ❑ Single Family Attached ❑ Existing Building ❑ X❑ ElMulti-Family El Existing Plus Addition Rear ' Front Orientation: (Northeast) 45 deg Floor Construction Type: ®Slab Floor Number of Dwelling Units: 1.00 0.38 Number of Stories: 1 ❑ Raised Floop i FFNFS;TRGTI()N Shadinq Devices Type Orientation Const. Component Type Frame Type Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a n/a 0.756 0.756 Exposed Slab MR -0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insolation Slab On Grade Solid Wood Door Wood 0.387 Exterior Door FFNFS;TRGTI()N Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Front (Northeast) 122.6 0.46 0.38 Bug Screen ❑ X❑ ❑ X❑ Left (Southeast) 172.5 0.46 0.38 Bug Screen ❑ X❑ ❑ X❑ Rear (Southwest) 308.3 0.46 0.38 Bug Screen ❑ X❑ ❑ a Right (Northwest) 195.8 0.46 0.38 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ I ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ i F ❑ ❑❑ ❑ ❑ ❑ ❑ I i i �- ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 08/23/04 11.26.13 Run Code: 1093285573 __ J EneroyPro 3.1 By EnergySoft User Number 3665 Job Number: Page:3 of 24 1 , Certificate of Compliance: Residential (Part 2 of 2) CF -'I R Lot #38 CcD The Hideaway 8/23/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Caamments (`antral Furnace 80% AFUE Du -ts in Attir 4.2 Setback HVAC -1 (Master Suita�) central Furnas 80% AFUE forts in Attic 4.2 Setback HV4r-2_(1 iving Area) ' Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments I Split Air Conditioner 14.0 SEER Ducts in Attic 47 S thack HVAC' -1 (Master Suites) Split Air Conditioner 14 0 SFFR Ducts in Attir 4 2 S -thack HVA(-9� iving Arca) _ Rated ' Tank Energy aF c -r- ' ater Heater Water Heater Distribution # in Input Cap. or Recov--ry Stand S stem Name Type Type Syst. Btu/hr (gal) Efficienc- Loss_1 For 6maLgas-atefage-(rateo inputs o an or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters Ifst energy For large gas storage water heaters (rated inpof greater than 75,000 Fktr)-tt� a e ndby Loss. For instantaneous gas water heaters, list Rated�npW-aad-Re overy Efficiency. REMARKS nal Tank Ins R -Value COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply wish Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requ res installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Gordon Ross Address: 42-829 Cook St. Suite #204 Palm Desert CA 92211 Telephone: (760) 568-1712 Lic. k4T4-VW t (signature) (date) Enforcement Agency Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDI—ZONING Address: 75-145 ST. CHARLES' PLACE PALM DESERT, CA X2211 Telephone: (760) 346-0855 A (signature) (date) Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 08/23/04 11:26:13 Run Code: 1093285573 !EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page:4 of 24 Certificate of Compliance: Residential (Addendum) CF -1 R 'Lit �3i The Hideaway8/23/2004 Project Title date 'Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. rhe local enforcement agency determines the adequacy of the justification, and may reject a building or design that ot.ierwise complies ' based on the adequacy of the special justification and documentation submitted. Plan i Field 1 The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. I The HVAC System "HVAC -1 (Master Suites)' must meet all CEC Criteria for a Zonally Controlled system serving on y Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Exposed Slab Floor, 3.50" thick at Master Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1095 sqft Covered Slab Floor, 3.50" thick at Master Suites ' The HVAC System "HVAC -2 (Living Area)' must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1867 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1867 sqft Exposed Slab Floor, 3.50" thick at Living Area ' HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Covered Slab Floor, 3.50" thick at Living Area t HERS Required Verification Tom___ �.._..._,._ ....... ti......s:�....,.�-x...41— f—f—1 K .—tifiori W;ZPq rnfor iinrior the stinarvision of a CEC aonroved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -1 (Master Suites)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified (HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Living Area)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified -iERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I' I i I I I i EnergyPro 11 By EnergySoft User Number: 3665 Job Number: Page:5 of 24 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. WI -en this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance speci-;cations for the mandatory measures whether thev are shown elsewhere in the documents or on this checklist only. I (DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable] � DESIGNER i ENFORCEMENT (Building Envelope Measures � U '§ 150(a): Minimum R-19 ceiling insulation. r I—I § 150(b): Loose fill insulation manufacturer's labeled R -Value. I—J j f § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does L^1 not apply to exterior mass walls). n '§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑J § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑i� Gas Appliances Gas Logs. § 150(e): Installation of Fireplaces, Decorative and . 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures) a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. I; EEEE; E § 150(1): Setback thermostat on all applicable heating and/or cooling systems. § 150Q): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. i 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. I4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. i 6. Piping insulating between heating source and indirect hot water tank. i i i IEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 24 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach.used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When his checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specificaWns for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. !DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER IENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) j §150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth, back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. J § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. j 3. Pool system has directional inlets and a circulation pump time switch. ! i _ I i I IX i §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no ! ! continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) I ! ii § 118 (f): Cool Roof material meet specified criteria ! I Lighting Measures § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for i general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting I control panel at an entrance to the kitchen. I 1 'X ; § 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 3665 Job Number: Page:7 of 24 - Computer Method Summary (Pa -t 1 of 3) C -2R 1 � Zbp Hide y 8/23/2Q04 Project Title Date ract29-824-2 -The fde I aQuin-ane#Ts I Building Permit # CONDITIONING (760) 346-0855BREEZEAIR Documentation Author Plan Check/Date � Telephone l_ ter Perfc)rrnanr'A 15 Field Check/Date 'Cnrnp Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance ' (kBtu/sf-yr) Design Design Margin ' Space Heating 4.03 3.50 0.53 Space Cooling 37.79 38.30 -0.52 Domestic Hot Water 8.23 8.23 0.00 ' Totals 50.05 50.03 0.02 Percent better than Standard: 0.0% BUILDING COMPLIES Total Conditioned Floor Area: 3,462 ft2 Floor Construction Type: Ei Raised Floor U Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 23.1 ' Number of Dwelling Units: 1.00 Total Conditioned Volume: 37,796 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 3,462 ft 2 'BUILDING ZONE INFORMATION # of Tkermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC' -1 actPL4tiitPq)1 345 13 450 039 Sle ping S1eE.pingSt2t_ 2 n/;; ' HVAC -2 (l iving Areal 2 117 24 346 _n fiL Living I Mng, tat 2 n/ Solar - - SURFACES Act. Gains 'OPAQUE Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Rnnf 1.345 0.02.8 345 _SL ❑ R-38 Roof (R 38 2x14.16) HVAr-1 v/all 50 0057 [XI ❑ R-21 Wall (W.2126 16) HVAC -1 —D —go Wafl 193 0 057 _ 45 _9R ❑ R-21 Wall (W 21 2x6 16) HVA _1 ' Wall 692�.�Q57- 135 90 ❑ R-21 Wall Oa,212x6.16) HVAC -1 Wall 88 0.na 225 90 I3 R-21 Wall (W2126.16) HVAC` -1 V1L81L— 750-0.5Z X711 qn R-21 Wall fW 1 2x6 161 HVAr-1 W_all 274 0.057 315 _3� EX ❑ R-21 Wall (W21.26. 6a HI/A('-1 -Ro.af— 2 117 0_028 345 0 ❑ R-38 Roof (R 382x14 16) HVAC -2 Wall_ 369.. 0 057 45_ _9.D_ W U R-21 Wall ON 2 ) H\/Ar-2 - Door 21 _0-381 — 45 9.n go ❑ Solid Wnori nor ❑ R-21 Wall HVnr_7 - 16) HVAC -2 -Wall— 243 0.051 _135 90 ily (W.21.26 ❑ R-21 Wall ?xF; 16) HVAC: -2 ' Wall— 30- 0.057 225 (W.21 !� ❑ R-21 Wall 2x6 16) HVAr-2 18/.811— 570 0 057 315 go (W.21 Ej❑ n —__ Run Initiation Time: 08123104 11:26:13 Run Code: 1093285573 _ EnergyPro 3.1 2y EnergySoft User Number: 3665 Job Number: Page:8 of 24 Computer Method Summary (Part 2 of 3) C -2R ' Lot #38 The Hideawa 8/23/2004 @ Y Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments \Mndoyt Front (Northeast) 15 n n 460_ n_38 45_ _9.0 Sierra Pacific Alum Clad HVAU-1 -I- 2 Window Front (Northeast) 2.2 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -1 3 Window Left (Southeast) 2.2 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 4 Window Left (Southeast) 2.2 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 5 Window Left (Southeast) 10.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 '6 Window Left (Southeast) 10.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 2_ Window Left (Southeast) 10.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 8 Window Left (Southeast) 15.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 6 VincLow Left( Southeast) 7.5 0 460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 '10 W n�1ow Left (Southeast) _2.2 ,460 0.38 �3 90 Sierra Pacific Alum Clad HVAC -1 11 Window Left (Southeast) 2.2 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -1 12 Window Rear (Southwest) 18.7 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -1 13 wiutow Rea (amdhmst) 48-0 11460 031 225 90 Sierra Pacific. Alum Clad HVAC -1 Window Rear (Southwest) 18.7 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -1 t14 15 Window Right (Northwest) 48.0 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -1 16 Window Right (Northwest) 24.0 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -1 17 Window Right (Northwest) 2.2 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -1 Window Right (Northwest) 2.2 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -1 '18 ' hi Window Front (Northeast) _10.2 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -9 20 Window Front (Northeast) 18.7 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -2 21 Window Front (Northeast) 48.0 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -2 Window Front (Northeast) 18.7 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -2 ',22 23 Window Front (Northeast) 10.0 0.460 0.38 45 90 Sierra Pacific Alum Clad HVAC -2 24 Window Left (Southeast) 15.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -2 25 Window Left (Southeast) 24.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -2 Window Left (Southeast) 48.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -2 '26 27 Window Left (Southeast) 24.0 0.460 0.38 135 90 Sierra Pacific Alum Clad HVAC -2 28 Window Rear (Southwest) 160.0 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -2 29 Window Rear (Southwest) 48.0 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -2 AND EXTERIOR SHADING Window Overhang Left Fin Right Fin 'INTERIOR # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 Bug Screen 0.76 '3 4 Bug Screen 0.76 = 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 - 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 1 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 _ 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 - 18 Bug Screen 0.76 19 Bug Screen 0.76 Bug Screen 0.76 '20 21, Bu Screen 0.76 = 22 Bug Screen 0.76 23 Bug Screen 0.76 Bug Screen 0.76 '24 25 Bug Screen 0.76 26 Bug. Screen 0.76 27 Bug Screen _ 0.76 _ _28- Bug Screen 0.76 ' 29 Bug Screen 0.76 �...__._.._____ Ru.rllnitiation Time: 08/204 11:2613 Run --t 115 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:9 of 24 1 _ Computer Method Summary (Par. 2 of 3) C -2R ' of #38 The Hideaway 8/23/2004 Project Title Date ' FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments Window Rear (S_nothwest) X5-0_ X480 0-38 _??,S _M S1Prm Pacific Alum Clad HVAC -7 '_.0. 31 Window Right (Northwest) 2.2 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 32 Window Right (Northwest) 2.2 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 , 33 Window Right (Northwest) 18.7 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 34 Window Right (Northwest) 48.0 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 ' 35 Window Right (Northwest) 18.7 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 Window Right (Northwest) 25.0 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 37 Window Right (Northwest) 2.2 0.460 0.38 315 90 Sierra Pacific Alum Clad HVAC -2 36 Window Right (Northwest) 2.2 0,411 38 315 10 Sierra Pacific Alum Clad HVAC -2 AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin 'INTERIOR # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 . 35 Bug Screen 0.76 Bug Screen 0.76 '36 37 Bug Screen 0.76 38 ' Buy Screen 0.76 Ru vitiation Time: 081 3104 11:26:13 Run Code: 109 285573 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:10 of 24 Computer Method Summary Insulation R -Val. Depth Location / Comments (Part 3 of 3 C -2R 19 0476 0.0 0 HVAQ-1 _Slab P .rQim_eter X44 _O_M 0.0 0 HVAC -1 ' Lot #38 The Hideaway 188 0_76 0.0 0 HVA(' -2 .SJnh Perimeter 8/23/2004 Project Title Central Furnace Date ' THERMAL MASS FOR HIGH MASS DESIGN 4.2 Setback HVAC -1 (Master Suites) Area Thick. Heat Ducts in Attic Inside Locaticn Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tole in Modar ESQ _Q.Z5 94 1L6Z n/a 0 )HVA(' -1 / Interior Mass Concrete, Heavyweight 250 3_50 28 0_98 n/a 0 HVAC -1 / Slab on Grade Heavyweight 1.095 3_50 _28 0.98 n/a 2 HVAC-)? / Slab an Grade ,Qg[lcretA Tile in Mortar 1.867 0_75 24 0_67 n/a 0 HVAC -2 / Interior Mass - .oncreJe-J:.ea4w2Jgbt 1.867 3.50 28 _91 n1a 0 HVAC -2 / Slab on Grade _ PERIMETER LOSSES Type F2 Length Factor Insulation R -Val. Depth Location / Comments SibPerimeter 19 0476 0.0 0 HVAQ-1 _Slab P .rQim_eter X44 _O_M 0.0 0 HVAC -1 Slab Perimeter 188 0_76 0.0 0 HVA(' -2 .SJnh Perimeter _21 0.76 0.0 0 HVAQ-2 HVAC SYSTEMS 'Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Type Locarion / Comments pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 (Master Suites) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 (Living Area) Pipe Pipe Insul. ' Hydronic Piping System Name Length Diameter Thick. Cooling Equipment Minimum Duct (air conditioner, Efficiency Location Duct Thermostat Location / 'Type heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments -aplit Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HV... AQ -1 (Chaster Suites) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2 (Living Area) R HEATING SYSTEMS r. Heater :m Name ndard Gas 50 aal or Less Rated' Tank Energy Fact' 1 Tank Insul. Water Heater istribution # in Input Cap. or Recovery Standby R -Value Type Type S st. (Btu/hr) (gal) Efficiercy Loss (%) Ext. Small Gas Standard 1 40.000 50 0.E2 n/a 12 1 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy facto,. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. RE Run Initiation Time: 08/23/04 11:26:13 Run Code: 1093285573 ___EnergyPro 3.1 By EnergySoft User Number 3665 Job Number: Paae:11 of 24 1 Com uter Method Summa Part 3 of 3 C -2R p r1/ ( ) tLot #38 a@ The Hideaway 8/23/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN ' Area Thick. Heat Type (sf) (in.) Cap. Cond. Form 3 Reference Concrete, Heavyweight .25.0 _3_5.0 _2fl 00.8. nig PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Inside Location R -Val. Comments _2 ±WLC2LS1abLoruGrade HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments ' Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Rated Tank Energy Fact! t Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) EfficLncy Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby _oss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:12 of 24 1 Comauter Method Summary (Addendum) C -2R Lot #38 (a, The Hideaway 8/23/2004 Project Title Date Special Features and Modeling Assumptions ' The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1 (Master Suites)" must meet all CEC Criteria for a Zonally Controlled system serving oily Sleeping Area . HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suiten HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Exposed Slab Floor, 3.50" thick at Master Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1095 sqft Covered Slab Floor, 3.50" thick at Master Suites The HVAC System "HVAC -2 (Living Area)" must meet all CEC Criteria for a Zonally Controlled system serving onik Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1867 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1867 sqft Exposed Slab Floor, 3.50" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 250 sqft Covered Slab Floor, 3.50" thick at Living Area HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC a.3proved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures or a form CF -61R. plan Field The HVAC System "HVAC -1 (Master Suites)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified: HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Living Area)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified -iERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. ' Run Initiation Time: 08/23/04 11:26:13 Run Code: 10932:35573 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 24 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lot #38 a The Hideaway 8/23/2004 THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 © 5.500 ❑ 0.625 El SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY R-21 Wall .21.2x6.16 Floor Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood TYPE (check one) Wall 5 Gypsum or Plaster Board LU10 W 7 Ceiling /Roof 8 2.60 9 N FRAMING MATERIAL Wood 0.680 23.11 H =O z FRAMING % 15 % Framing 14.81 TOTAL HC 3.7 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 © 5.500 ❑ 0.625 El SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 © 5.500 ❑ 0.625 El SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.0001 5.445 0.562 0.562 0.31 2.631 0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.11 7.56 Rc Rf EI�M `HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0433 x 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.631 0.37 0.98 2.60 0.26 0.68 14.81 TOTAL HC 3.7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 x 0.85 ] + [ 0.1323 X 0.15 ] 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:14 of 24 I HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #38 @ The Hideaway 8/23/2004 SYSTEM NAME FLOOR AREA HVAC -1 Master Suites 1,345 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,400 Total Output (Btuh) 89,400 Output (Btuh/sqft) 66.5 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 43.5 Total Output (sgft/Ton) 275.9 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.49 Airflow (cfm/Ton) 410.3 Outside Air (%) 5.0 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions 24.0 of 310� Outside Air 101 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensiblel Latent I I CFM I Sensible 1,53 30,060 3,694 569 23,375 0 1,503 1,169 0 0 10 3,856 2,17 101 4,950 0 0 1,5031 1 1,169 36,92 5,865 30,663 HS26-060/G40UH60C-110 (5) 46,132 6,091 89,400 Total Adjusted System Output 46,132 6,091 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 67.2 of ® 108.6 of Heating Coil Supply Fan 2000 cfm 108.6 of 3h Eupply Air Ducts `S •108.0 of ROOMS 70.0 of Return Air Ducts `S -OOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peala 114.1 / 80.3 of 80.5 / 65.9 of 59.1 / 57.7 of 59.1 / 57.7 of O Supply Air Ducts Outside Air 101 cfm Cooling Coil Supply Fan 59.8 / 58.0 of 2000 cfm 49.4% R.H. ROOMS 78.7/65.10F 78.0/64.8OF Return Air Ducts ` I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 24 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #38 @ The Hideaway 8/23/2004 SYSTEM NAME FLOOR AREA HVAC-2(Living Area 2,117 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 2 Heating System Output per System 89,400 Total Output (Btuh) 178,800 Output (Btuh/sgft) 84.5 Cooling System Output per System 58,500 Total Output (Btuh) 117,000 Total Output (Tons) 9.8 Total Output (Btuh/sgft) 55.3 Total Output (sgftrron) 217.1 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sqft) 1.89 Airflow (cfmrron) 410.3 Outside Air (%) 4.0 Outside Air (cfm/sqft) 0.07 Note: values above given at ARI conditions ' EATING S 24.0 of ) ;I 1 Outside Air 159 cfm ' I 69.6 of ' 114.1/80.30F >---V Outside Air 159 cfm I 78.6/64.60F 67.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFMISensiblel 924 Latent CFM Sensible 2,693 54,814 6,368 924 38,608 0 2,741 1,930 0 0 159 6,079 3,636 159 7,808 0 0 2,7411 1 1,930 66,374 10,004 50,277 HS26-060/G40UH60C-110 (5) 92,982 10,457 178,800 Total Adjusted System Output g2 98^ 10,457 178,800 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 109.2 of Heating Coil 109.2 of O Supply Air Ducts Supply Fan 108'7 of 4000 cfm ROOMS 70.0 of Return Air Ducts I 80.0/65.40 58.5 / 57.1 of 58.5 / 57.1 of S I A; r% D t Cooling Coil O C, .1,V y uc s -31 Supply Fan 59.1 / 57.3 of 4000 cfm48.1% R.H. ROOMS 78.0 ! 64.4 of Return Air Ducts 1 agof 24 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Pe:16 ROOM LOAD SUMMARY PROJECT NAME Lot #38 @ The Hideaway DATE 8/23/2004 SYSTEM NAME HVAC -1 Master Suites FLOOR AREA 1,345 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLIN 3 PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 Master Suites 1 1,531 30,060 3,694 1,531 30,060 3,694 569 23,375 PAGE TOTAL 1 1,531 30,060 3,6941 569 23,375 TOTAL 1 1,531 30,060 3,694 569 23,375 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 24 ROOM LOAD SUMMARY PROJECT NAME Lot #38 @ The Hideaway DATE 8/23/2004 SYSTEM NAME HVAC-2(Living Area FLOOR AREA 2,117 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLIN3 PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -2 Living Area 1 2,693 54,814 6,368 2,693 54,814 6,368 924 38,608 PAGE TOTAL 1 2,693 54,814 6,368 924 38,608 TOTAL 1 2,693 54,814 6,368 924 38,608 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 18 of 24 ROOM HEATING PEAK LOADS Project Title Date Lot #38 (W The Hideaway 8/23/2004 Room Information Desi n Conditions Room Name Master Suites Time of Peak Jan 12 am Floor Area 1,345 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 700E Conduction Area U -Value AT OF Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 809 Infiltration: L 1.001 x 1.080 x 1 345 x 10.00 x 6] x 46 = 5 566 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,375 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 24 1345.0 X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x x 0.0280 X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x- x x x x >•- x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = _ = = = = _ = = = 1,733 - - 1,370.4 0.0566 46.0 3,570 240.6 0.4600 46.0 5,090 perimeter =163.0 45.5 7,416 - Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 809 Infiltration: L 1.001 x 1.080 x 1 345 x 10.00 x 6] x 46 = 5 566 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,375 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 24 ROOM HEATING PEAK LOADS Project Title Date Lot #38 C� The Hideaway 8/23/2004 Room Information Design Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 2,117 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 28,533 Infiltration: L 1.001 x 1.080 x 2 117 x Height x 60] x 46 = 10 075 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 38,608 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 20 of 24 2,117.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x 46.0 x 46.0 x 46.0 x 46.0 x 45.5 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x = = = = = = = = = = = = = = = = 2,727 1,572.0 0.0566 4,095 21.4 0.3872 381 558.6 0.4600 11821 erimeter = 209.0 9,510 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 28,533 Infiltration: L 1.001 x 1.080 x 2 117 x Height x 60] x 46 = 10 075 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 38,608 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 20 of 24 I I RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #38 @ The Hideaway 8/23/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Roof Area U -Value Master Suites 78°F 115°F 370E X X X X X X X X X DETD' = = = = = = = = = Btu/hr 56.0 2,109 35.6 2,763 37.0 4,095 FxdGlsWdw N1 (Southeast) FxdGlsWdw M3 (Southeast) FxdGlsWdw M2 (Southeast) FxdGlsWdw M1) (Southeast) FxdGlsWdw 1-4 Southeast 6 0.423 1. Design Equivalent Temperature Difference (DETD) Page Total 8 s66 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FXdGISWdW N3 Northeast Fxd-G.ls- d.W_(Q3 (Northeast) FXdGISWdW 02 (Southeast) FxdGlsWdw 01 (Southeast) FxdGlsWdw (N2) (Southeast) FxdGlsWdw N1 (Southeast) FxdGlsWdw M3 (Southeast) FxdGlsWdw M2 (Southeast) FxdGlsWdw M1) (Southeast) FxdGlsWdw 1-4 Southeast ( 0.0 X X X x X X x x X x 1 + + + + + + + + +7.5 + 15.0 X x X x X X x X x X 4 ) X ) x ) X X X ) X x ) X 0.423 = = = = = = = = __ = 305 ( 0.0 1 2.2 4 0.423 46 ( 0.0 1 2.2 6 0.423 59 ( 0.0 1 2.2 62)x 0.423 59 ( 0.0 15 10.0 62)x 0.423 262 ( 0.0 1 10.0 62) 0.423 262 ( 0.0 15 10.0 6-.) 0.423 262 ( 0.0 1 15.0 6'. 0.423 393 ( 0.0 1 62) 0.423 197 ( 0.0 15 2.2 6'. 0.423 59 Sched. Page Total 1 soa ' _ Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,345 X 0.500 Watts/sqft x 3.41 Etuh/Watt _ 2,295 Occupants 1.00 X 1,345 X 250 Btuh/occ. / 200 sgft/occ. = 1,681 ' Receptacle 1.00 x 1,345 x 1.500 Watts/sgft x 3.413 Etuh/Watt _ 6,886 Process 1.00 x 1,345 x 0.000 Watts/sqft x 3.41 E�tuh//W1att X01 Infiltration: LQo x Q80 x 1 345 x 0 QO x 59 /6o] L__37J ' Schedule Air Sensible Area Ceiling Height ACH \T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,060 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 X 1 345 X 2001 Btuh/OCC. / 200 sgft/occ. = 1345 Receptacle 1.00 X. 1345 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Process 1.00 X 1 345 X 0.000 Watts/sqft X 3.41 Btuh/Watt = o Infiltration: 1.00 X 4 840 X 1 34 X 10.00 X0.50 / 60] -0.00433 = 2349 ' Schedule Air Latent Area Ceiling Height ACH \W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,694 ' EnergyPro 3.1 By EnergySoft user Number: 3665 Job Number: Page: 21 of 24 � I RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #38 0- The Hideaway 8/23/2004 Project Title Date Room Name Master Suites Design Indoor Dry Bulb Temperature: 780E Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 37°F Conduction Area U -Value X DETDBtu/hr X = X = X = X = X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page"TOtal 0 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw L3) (Southeast) Exd.GtsVALdw r (Southwest) FrnchDr 11 Southwest FxdGlsWdw L1 (Southwest) FrnchDr (12) (Northwest) FxdGlsWdw N4 (Northwest) FxdGlsWdw 05 (Northwest) FxdGlsWdw 04 (Northwest) 489 ( 0.0 1 48.0 ( 0.0 X1 X X x x X x X x x + + + + + + + + +x + 2.2 X X x x x x X X x E2) x ) X X X X X X )X )x 0.423 = = = = = = = = = = 59 ( 0.0 1 18.7 0.423 489 ( 0.0 1 48.0 E2) 0.423 1,259 ( 0.0 1 18.7 E2) 0.423 489 ( 0.0 1 48.0 z8) 0.423 975 ( 0.0 1 24.0 z 8) 0.423 487 ( 0.0 1 2.2 rA 0.423 46 ( 0.0 1 2.2 -8)x 0.423 46 ( ( Sched. Page Total 3 850 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,345 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 2,295 Occupants 1.00 X 1,345 X 250 Btuh/OCC. / 200 sgft/occ. = 1,681 ' Receptacle 1.00 x 1,345 x 1.500 Watts/sqft x 3.413 Btuh/Watt c 6,886 Process 1.00 x 1,345 x 0.000 Watts/sqft X 3.413BtuhlWatt 00I Infiltration: 00 x 0$0 x 39.5 x l 10_Oo x 050 / 6�] L 3ZJ ' Schedule Air Sensible Area Ceiling Height ACH Z_\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,060 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,345 x 200 Btuh/occ. / 200+ sgft/occ. = 1345 ' Receptacle 1.00 X 1,345 X 0.000 Watts/sqft x 3.413 BtuhfWatt = 0 Process 1.00 x 1,345 X 0.000 Watts/sqft x 3.41? Btuh/Watt = 0 Infiltration: [ 1.001 x 4840 x 1 345 x 10.00 x 0.50 / 60] 1 0.00433 = 2349 ' Schedule Alr Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,694 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #38 @ The Hideaway 8/23/2004 Project Title Date Room Name Living Area Design Indoor Dry Bulb Temperature: 7800F Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F Conduction Area U -Value 117 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF FXdGISWdw (B1) (Northeast) E dG.Is-W-dw-( (Northeast) Ent Dr 1 (Northeast) FxdGISWdW Al (Northeast) FxdGlsWdw (P1) (Northeast) CsmntWdw(Cl)(Southeast) 1 FxdGlsWdw K5 (Southeast) FrnchDr 9 (Southeast) FxdGlsWdw (K4) (Southeast) Sld GlsDr 10 Southwest ( 0.0 X X X x X x x x x X 1 + + + + + + + + + + ( 0.0 15 ( 0.0 1 ( 0.0 15 ( 0.0 1 ( 0.0 1 ( 0.0 1 ( 0.0 15 ( 0.0 15 ( 0.0 1 DETD 1 X 56.0 X 35.6 X 35.6 X 37.0 X X X X X Btu/hr 3,320 3,169 295 9,508 Sched. Page Total 9 246 - Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,117 x 0.500 Watts/sqft x 3.41 Btuh/Watt _ 3,613 Occupants 1.00 X 2,117 X 250 Btuh/occ. / 200 sqft/occ. = 2,646 ' Receptacle 1.00 x 2,117 x 1.500 Watts/sgft x 3.413 Btuh/Watt _ 10,838 Process 1.00 X 2,117 x 0.000 Watts�/sgfttx 3.41 BtuhfWatt 0 Infiltration: [ 1_00 x 080 x x X11...501 x [ o,50J / 60] � = a,1oa ' Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,814 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 xA21 x 200 Btuh/occ. / 200 sgft/occ. = 2 117 ' Receptacle 1.00 x x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x x 0.000 Watts/sqft x 3.41 BtuhMatt = 0 Infiltration: [1.00 x 4,8401 X 2 117 x 11.50 x 0.50 / 60] 0.00433 = 4 251 ' Schedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,368 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 24 Page Total 16 292 Unshaded Area SGF SC Btu/hr 10.0 X 48) X 0.423 = 203 18.7 X 48 )x 0.423 = 379 48.0 X 48) X 0.423 = 975 18.7 X 48)x 0.423 = 379 10.0 X 48) x 0.423 = 203 15.0 X 62) X 0.423 = 393 24.0 x 62) X 0.423 = 629 48.0 X 62) X 0.423 = 1,259 24.0 X 62) X 0.423 = 629 160.0 X 62 )xl 0.423 = 1 4,196 Sched. Page Total 9 246 - Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,117 x 0.500 Watts/sqft x 3.41 Btuh/Watt _ 3,613 Occupants 1.00 X 2,117 X 250 Btuh/occ. / 200 sqft/occ. = 2,646 ' Receptacle 1.00 x 2,117 x 1.500 Watts/sgft x 3.413 Btuh/Watt _ 10,838 Process 1.00 X 2,117 x 0.000 Watts�/sgfttx 3.41 BtuhfWatt 0 Infiltration: [ 1_00 x 080 x x X11...501 x [ o,50J / 60] � = a,1oa ' Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,814 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 xA21 x 200 Btuh/occ. / 200 sgft/occ. = 2 117 ' Receptacle 1.00 x x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x x 0.000 Watts/sqft x 3.41 BtuhMatt = 0 Infiltration: [1.00 x 4,8401 X 2 117 x 11.50 x 0.50 / 60] 0.00433 = 4 251 ' Schedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,368 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #38 @ The Hideaway 8/23/2C04 Project Title Date Room Name Living Area Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F Conduction Area U -Value 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Btu/hr Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr 8 (Southwest) CsmnLWdw-(K3.) (Southwest) FxdGlsWdw K2 Northwest FxdGlsWdw K1 (Northwest) FxdGlsWdw (J2) (Northwest) FrnchDr 6 (Northwest) FXdGISWdW J1 (Northwest) CsmntWdw 11 (Northwest) FxdGlsWdw (H2) (Northwest) FxdGlsWdw H1 Northwest ( 0.0 x x x x x x x x x x 1 + + + + + + + + + + 48.0 X X x x x x x X X X E'2) x X )X x x X x ) x 0.423 = = = = = = = = = = 1,259 ( 0.0 15 15.0 E•2) 0.423 393 ( 0.0 1 2.2 -8 0.423 46 ( 0.0 1 2.2 -8) 0.423 46 ( 0.0 1 18.7 �8) 0.423 379 ( 0.0 1 48.0 48)X 0.423 975 ( 0.0 1 18.7 48)X 0.423 379 ( 0.0 1 25.0 48) 0.423 508 ( 0.0 15 2.2 48) 0.423 46 ( 0.0 1 2.2 •48 0.423 46 ' Sched. Page Total a 075 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,117 x 0.500 Watts/sqft x 3.41 Btuh/Watt = 3,613 Occupants 1.00 X 2,117 X 250 Btuh/occ. / 200 sgft/occ. = 2,646 ' Receptacle 1.00 x 2,117 x 1.500 Watts/sqft x 3.413 Btuh/Watt = 10,838 Process 1.00 x 2,117 X 0.000 Watts/sqft x 3.413Btuh/Watt o Infiltration: _00 x Q80 x X172 x 50 x 0-0 / 60] �37J = 8,10 ' Schedule Air Sensible Area Ceiling Height ACH Z -\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,814 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2117 x 200 Btuh/OCC. / 200 sgft/occ. = 2117 ' Receptacle 1.00.x 2117 x 0.000 Watts/sqft x 3.412 Btuh/Waft = o Process 1.00 x 2117 X 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: 1.00 x 4 840 x 2 11 X 11.50 x 0.50 / 60] 1 0.00433 = 4 251 ' chedule Alr Latent Area Ceiling Height ACH /-\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,368 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 24 TITLE 24 REPORT Title 24 Report for: Lot #38 @ The Hideaway (Casita) Lot #38, Tract 29894-2 - The Hideaway La Qu i nta, CA 92253 Project Designer: Gordon Ross 42-829 Cook St., Suite #204 Palm Desert, CA 92211 (760) 568-1712 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 8/23/2004 i The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 6 8 12 13 14 - -15 16 EnergyPro 3.1 By EnergySoR Job Number: User Number. 3665 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #38 CcD- The Hideaway (Casita) 8/23/2004 Project Title Date Lot #38 Tract 29894-2 - The Hideaway La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan ,heck/Date Documentation Author Telephone Computer Performance 15 Field Check! Date . Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 344 ft2 Average Ceiling Heighf: 9.0 ft Total Conditioned Slab Area: 344 ft2 Building Type: (check one or more) Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northeast) 45 deg Number of Dwelling Units: 1.00 Number of Stories: 1 ' BUILDING Component Tvoe Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Frame Assembly Location/Comnents Type U -Value (attic, garage, typal, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter In sulation FFNFSTRATlr)N Shadine Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (Southeast) 15.0 0.46 0.38 Bug Screen ❑ K1 ❑X❑ Rear (Southwest) 50.2 0.46 0.38 Bug Screen ❑ x❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 08/20/04 08:00:48 Run Code: 1093014048 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:3 of 16 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Lot #38 The Hideaway (Casita) 8/23/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct•or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments C:Antral Fiirnara 80% AFUE Ducts in Attic 42 Setback H\1AC-1 (Guest Casita) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat ' Meat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Split Air Conditioner 14.0 SEER Ducts in Attic 42 Setback WATER HEATING SYSTEMS Water Heater "----Wate—r Heater Distribution # in hpt System Name Type Type Syst. Btb, Location / Comments 1 Tank or ov, ry External Cap. or ov, ry Stan Tank Insul. (gal fficiency L s (%) R -Value 50 C-53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Stu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency End Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV' 3 requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Gordon Ross Address: 42-829 Cook St., Suite #204 Palm Desert, CA 92211 Telephone: (760) 568-1712 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST- CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 S 0,4, (signature) (date) IEnergyPro 3.1 By EnergvSoft User Number. 3665 Job Number. Page:4 of 16 1 Certificate of Compliance: Residential Addendum CF -1 R 'Lot #38 (W The Hideaway (Casita) 8/23/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local PnfnrrPmPnt anpncv determines the adeauacv of the iustification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. 'HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -1 (Guest Casita)" includes Refrigerant Charge and Airflow Credit (or a TXV). A ;ertified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Guest Casita)' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on .a CF -6R Form. ' Run Initiation Time: 08/20/04 08:00:48 Run Code: 1093014048 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number. Page:5 of 16 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance app oach used. Items marked with an ' asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. V�hen this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a'§ 150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. * §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. FX Gas Appliances Gas Logs. § 150(e): Installation of Fireplaces, Decorative and 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a§ 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 16 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa:h used. Items marked with an ' asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether thev are shown elsewhere in the documents or on this checklist only. I DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) C150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78%, thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑§118 (f): Cool Roof material meet specified criteria Lighting Measures 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. I I 3.1 By EnergySoft User Number: 3665 Job Number: Page:7 of 16 Computer Method Summary (Part 1 of 3) C -2R _Lo#A3.8_ a-The-H.i.d.e.aw-ay_(Cas.ita) 812312Q04 Project Title _L.ot_#3.8,sr_act2.98.942- The-i.i.d.e_aW.ay La_O-uinta Date Project Address Building Permit # (760) 346-0855 _BREEZE-ALLR-C-QNDELORING Documentation Author Telephone PIan:Check/Date �oml2uteLP�lfoO]1af1Ce 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.73 2.58 1.14 Space Cooling 68.06 63.22 4.84 Domestic Hot water 52.44 51.73 0.71 Totals 124.22 117.53 6.69 Percent better than Standard: 5.4% BUILDING COMPLIES Total Conditioned Floor Area: 344 ft2 Floor Construction Type: ❑ Raised FloorX❑ -Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 19.0% Number of Dwelling Units: 1.00 Total Conditioned Volume 3,096 ft' Number of Stories: 1 Total Conditioned Slab Area 344 ft 2 BUILDING ZONE INFORMATION # of —hermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC: -1 ((,tieStCHsiia) 344 30 99& 1.00 C nnditioned— SPthgrk n/a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Boot— 344 x.928- 345 _0 Wall 203 —0-0.51 45_ 90 WA1 89 —057_ 135 —90 Wall_ 45 o.057- 180 _90 1Na11_ 121 0.057 225 _90 -WWII 135 0.057 315 g0_ Solar Gains Y / N Form 3 Reference �'/ ■ ;.. �/ ■ �- ■ ■ Location / Comments HVAC -1 HVAC: -1 HVAC -1 HVAC: -1 HVAC -1 HVAC -1 I EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page:8 of 16 1 ' 'computer Method Summa Pert 2 of 3 C -2R 'Lot #38 @ The Hideaway (Casita) 8/23/2004 Project Title Date: FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 3 Window---Left---�Southeast) —15_.0_ —0-6D- 0_3.11 ---J.35_ _90 SietraPacific Alum Clad HVAC -1 2 Window Rear (Southwest) 48.0 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -1 ' 3 Window Rear (Southwest) 2.2 0.460 0.38 225 90 Sierra Pacific Alum Clad HVAC -1 1 — ' INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Ler.. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 ' 2 Bug Screen 0.76 3 Bug Screen 0.76 Run Initiation Times 08/20/04 08.00.48 Run Code: 1093014048 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:9 of 16 Computer Method Summary (Part 3 of 3) C-2R #38 @ The Hideaway (Casita) 8/23/2004 'Lot Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location ' Type (so (in.) Cap. Cond. Form 3 Reference R-Val. Conments PERIMETER LOSSES ' F2 Insulation Type Length Factor R-Val. Depth Location / Comments Perimeter 3 0.76 0.0 0 HVAC-1 'lab Slab-Berimeief 70 -O-Z6 QJ0 _9 HVAQ-1 ' HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / ' pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R-Value Type Comments Central Furnace 80° E Ducts in Attic 4.2 Setback HVAC-1 (Guest Casita) 'Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ' Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R-Value Type Comments ' split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback F'VAC-1 (Guest Casita) WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Heater Water Heater Distribution # in Input Cap. or Recovery Standby R-Value 'Water System Name Type Type Syst. (Btu/hr) (gal) Effic-ency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40.000 50 153 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy fa ;tor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby: Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. ' Computer Method Summa AdJendum C -2R 'Lot #38 (cD The Hideaway (Casita) 8/23/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aoencv determines the adequacy of the justification, and may reject a building or design that otherwise complies HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R.plan Field The HVAC System "HVAC -1 (Guest Casita)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Guest Casita)" is using reduced duct leakage to comply and must have diagnostic _ite testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. ' Run Initiation Time: 08/20/04 08:00:48 Run Code: 1093014048 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number. Page: 11 of 16 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 I PROJECT NAME Lot #38 @ The Hide Casita) --]-DATE 8/23/2004 CONSTRUCTION COMPONENTS DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY R-21 Wall W.21.2x6.16' Floor Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood TYPE (check one) X Wall 5 Gypsum or Plaster Board W W 7 Ceiling t Roof 8 2.60 O ) UFn 13 FRAMING MATERIAL Wow 0.680 7.56 Fr% / 100 ASSEMBLY U-VALUI =O FRAMING % 15 % Framing % 14.8 TOTAL HC 3.7 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) CONSTRUCTION COMPONENTS SUBTOTA R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 1 / Rc INSIDE SURFACE AIR FILM SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.4651 0.465 21.000 5.445 0.562 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 1 / Rc 0.680 23.11 0.680 7.56 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) Rf 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U-VALUI 14.8 TOTAL HC 3.7 . Rc Rf 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. X 0.85 ] + 11 0.1323 1 X L 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U-VALUI COMMENTS ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 2of16 HVAC SYSTEM HEATING AND COOLING LOADS SUMmARY PROJECT NAME DATE Lot #38 @ The Hideaway (Casita) 8/23/2004 SYSTEM NAME FLOOR AREA HVAC -1 Guest Casita 344 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK IICOILHTG.PEA9 CFMISensiblel Latent 11CFM1 Sensible 37 8,365 885 188 7,971 0 418 399 0 0 26 992 69 1 26 1,268 0 0 418 399 10,193 1,576 1 1Q036 HS26-024/G40UH24A-045X (2) 19,858 913 36,000 Total Adjusted System Output19,858 913 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am 1HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 24.0°F 68.10F 109.8°F 109.8°F O Supply Air Ducts Outside Air 26 cfm109.3 °F Heating Coil Supply Fan 800 cfm ROOMS 70.0 OF 69.5 OF k Return Air Ducts %I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peat 114.1 / 80.3 OF 79.6 / 64.0 OF 56.6 / 55.2 OF 56.6 / 55.2 OF co.,Supply Air Ducts Outside Air 26 cfm Cooling Coil Supply Fan 57.1 / 55.4 OF 800 cfm 44.2% R.H. ROOMS 78.5/63.4 °F 78.0 / 63.3 OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 16 1 ROOM LOAD SUMMARY PROJECT NAME Lot #38 @ The Hideaway Casita DATE 8/23/2004 SYSTEM NAME HVAC -1 Guest Casita FLOOR AREA 344 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLIN3 PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLEHVAC-1 CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 1 371 8,365 1885 371 8,3e5 885 188 7,971 PAGE TOTAL 1 371 8,;•65 885 188 7,971 TOTAL 1 371 8, .65 885 188 7,971 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 14 of 16 ROOM HEATING PEAK LOADS Project Title Date Lot #38 @ The Hideaway_ Casita) 8%23/2004 Room Information Design Conditions Room Name HVAC -1 Time of Peak Jan 12 am Floor Area 344 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr 344.0 X 0.0280 x 46.0 = 443 592.8 X 0.0566 x 46.0 = 1,544 65.2 x 0.4600 x 46.0 = 1,381 perimeter = 73.0 x x 45.5 = 3,322 x x = x x = x x _ x x = x x = x x = x x = x x = x x = x x = x x = - x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 6 689 Infiltration: I1.00 X 1.080 X 344 X 9.00 X 0.50 / 60] X 46 = 1 281 chedule Air Sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,971 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number. Page: 15 of 16 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #38 I,W The Hideaway_ Casita) 8/23/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: HVAC -1 78°F 115DF 37°F Conduction Area U -Value DETDBtu/hr X 56.0 = 539 X 35.6 = 1,195 X 37.0 = 1 111 X — X = X = X _ X = X = i 1. Design Equivalent Temperature Difference (DETD) Page Total 2 845 Items shown with an asterisk (') denote conduction through an interior surface to another room. ' Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btulhr CsmntWdw F1 (Southeast) ( 0.0 x 1 + 15.0 x 32) X 0.423 = 393 ' (Southwest) ( 0.0 x 1 + 48.0 x 32) x 0.423 = 1,259 FAGlsWdw E1 (Southwest) ( 0.0 x 1 + 2.2 X 32)x 0.423 = 59 ( x + x )x = ( x + x )x = ' ( x + x )x = ( x + x )x ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total 1 711 ' Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 344 x 0.500 Watts/sqft x 3.41 Btuh[Watt = 587 ' Occupants 1.00 X 344 X 250 Btuh/occ. / 200 sgft/occ. _ 430 Receptacle 1.00 x 344 X 1.500 Wafts/sqft x 3.41 Btuh/Watt 1,761 Process 1.00 x 344 x 0.000 Watts/sqft x 3.41: Btuh/Watt — 0 Infiltration: x =080 x 344 x 9.00 x 60] 0 = chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,365 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 344 x 2001 Btuh/occ. / 2a] sgft/occ. = 344 Receptacle 1.00 X 344 x 0.000 Wafts/sqft X 3.41 Btuh[Watt = 0 Process I�1.00 x 344 x 0.000 .Watts/sgft x 3.4 Btuh/Watt = 0 Infiltration: I 1 ool x 4 840 x 344 x 9.00 x 0.50 / 60] 0.00433 = 541 Schedule Air Latent Area Ceiling Height ACH _W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 885 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 16 ' Type Description Sierra Pacific Windows Thermal Performance Data Glazing type CPA G -value res nres SHGC res nres V, 'as nres Casement Windows DC Wood Casement Window Single glaze Clear Wide grid bar SG/WD 001 0.42 0.95 0.52 0.54 0.52 0.56 DC Wood Casement Window Single glaze Clear Narrow grid bar SG/NR 001 0.3 0.94 0.57 0.58 0.58 0.62 WC Wood Casement Window Single glaze Clear Wide grid bar SG/WD 001 0.42 0.95 0.52 0.54 0.52 0.56 Wood Casement Window Single glaze Clear Narrow grid bar SG/NR 001 0.3 0.94 0.57 0.58 0.58 0.62 'WC WC Wood Casement Window Single glaze Clear SG 001 0.42 0.96 0.62 0.63 0.63 0.67 WC Wood Casement Window Insulated glass Clear Wide grid bar IG/WD 001 0.46 0.47 0.47 0.46 0.47 0.5 WC Wood Casement Window Insulated glass Clear Narrow grid bar IG/NR 001 0.45 0.47 0.51 0.5 0.52 0.55 Wood Casement Window Insulated glass Clear_+ IG 001 0.45=' 0.47 0.5Cr> 0.55 0.57 0.6 'WC WC Wood Casement Window Insulated glass LoE2 Wide grid bar IG/WD/LE 001 0.-13 0.32 0.26 0.27 0.42 0.44 WC Wood Casement Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 001 0.33 0.32 0.28 0.29 0.46 0.48 WC Wood Casement Window Insulated glass LoE2-4 IG/LE 001 0.=3 r 0.32 0.31-"-, 0.31 0.51 0.53 DC Wood Casement Window Insulated glass Clear Wide grid bar IDL 001 0.48 0.48 0.47 0.46 0.47 0.5 Wood Casement Window Insulated glass LoE2 Wide grid bar IDL/LE 001 0.=7 0.36 0.26 0.27 0.42 0.44 'DC DC Wood Casement Window Insulated glass EE 140 Wide grid bar IDL/EE 001 0._7 0.37 0.17 0.17 0.23 0.23 WC Wood Casement Window Insulated glass EE 140 Wide grid bar IG/WD/EE 001 0.33 0.33 0.17 0.17 0.23 0.23 WC Wood Casement Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 001 0.33 0.33 0.18 0.19 0.25 0.26 Wood Casement Window Insulated glass EE 140 IG/EE 001 0.=3 0.33 0.2 0.2 0.28 0.28 'WC Casement Half Round Windows DCH Wood Casement Half Round Window Single glaze Clear Wide grid bar SG/WD 001 O.S2 0.95 0.52 0.54 0.52 0.56 DCH Wood Casement Half Round Window Single glaze Clear Narrow grid bar SG/NR 001 09 0.94 0.57 0.58 0.58 0.62 CH Wood Casement Half Round Window Single glaze Clear Wide grid bar SG/WD 001 0.S2 0.95 0.52 0.54 0.52 0.56 CH Wood Casement Half Round Window Single glaze Clear Narrow grid bar SG/NR 001 09 0.94 0.57 0.58 0.58 0.62 CH Wood Casement Half Round Window Single glaze Clear SG 001 O.S2 0.96 0.62 0.63 0.63 0.67 CH Wood Casement Half Round Window Insulated glass Clear Wide grid bar IG/WD 001 0.�6 0.47 0.47 0.46 '0.47 0.5 CH Wood Casement Half Round Window Insulated glass Clear Narrow grid bar IG/NR 001 0.-6 0.47 0.51 0.5 0.52 0.55 Wood Casement Half Round Window Insulated glass Clean IG 001 0:-6;s 0.47 0.50- 0.55 0.57 0.6 CH Wood Casement Half Round Window Insulated glass LoE2 Wide grid bar IG/WD/LE 001 0.33 0.32 0.26 0.27 0.42 0.44 'CH CH Wood Casement Half Round Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 001. 033 0.32 0.28 0.29 0.46 0.48 CH Wood Casement Half Round Window Insulated glass LoE2:; IG/LE 001 0.33, 0.32 UP 0.31 0.51 0.53 DCH Wood Casement Half Round Window Insulated glass Clear Wide grid bar IDL 001 0.48 0.48 0.47 0.46 0.47 0.5 Wood Casement Half Round Window Insulated glass LoE2 Wide grid bar IDL/LE 001 0.37 0.36 0.26 0.27 0.42 0.44 'DCH DCH Wood Casement Half Round Window Insulated glass EE 140 Wide grid bar IDL/EE 001 037 0.37 0.17 0.17 0.23 0.23 CH Wood Casement Half Round Window Insulated glass EE 140 Wide grid bar IG/WD/EE 001 0..33 0.33 0.17 0.17 0.23 0.23 CH Wood Casement Half Round Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 001 0.33 0.33 0.18 0.19 0.25 0.26 CH Wood Casement Half Round Window Insulated glass EE 140 IG/EE 001 0.33 0.33 0.2 0.2 0.28 0.28 Radius Casement Windows DRC Wood Radius Casement Window Single glaze Clear Wide grid bar SG/WD 001 0.32 0.95 0.52 0.54 0.52 0.56 DRC Wood Radius Casement Window Single glaze Clear Narrow grid bar SG/NR 001 C.9 0.94 0.57 0.58 0.58 0.62 RC Wood Radius Casement Window Single glaze Clear Wide grid bar SG/WD 001 0.32 0.95 0.52 0.54 0.52 0.56 RC Wood Radius Casement Window Single glaze Clear Narrow grid bar SG/NR 001 C.9 0.94 0.57 0.58 0.58 0.62 Wood Radius Casement Window Single glaze Clear SG 001 0.32 0.96 0.62 0.63 0.63 0.67 'RC RC Wood Radius Casement Window Insulated glass Clear Wide grid bar IG/WD 001 0.:46 0.47 0.47 0.46 0.47 0.5 RC Wood Radius Casement Window Insulated glass Clear Narrow grid bar IG/NR 001 0,46 0.47 0.51 0.5 0.52 0.55 RC Wood Radius Casement Window Insulated glass Clean IG 001 .0:46 0.47 MP 0.55 0.57 0.6 Wood Radius Casement Window Insulated glass 1oE2 Wide grid bar IG/WD/LE 001 0.33 0.32 0.26 0.27 0.42 0.44 RC Wood Radius Casement Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 001 0.33 0.32 0.28 0.29 0.46 0.48 'RC RC Wood Radius Casement Window Insulated glass LoE2:3 IG/LE 001 020, 0.32 UV' 0.31 0.51 0.53 DRC Wood Radius Casement Window Insulated glass Clear Wide grid bar IDL 001 0.48 0.48 0.47 0.46 0.47 0.5 DRC Wood Radius Casement Window Insulated glass LoE2 Wide grid bar IDULE 001 037 0.36 0.26 0.27 0.42 10.44 DRC Wood Radius Casement Window Insulated glass EE 140 Wide grid bar IDL/EE 001 037 0.37 0.17 0.17 0.23 0.23 RC Wood Radius Casement Window Insulated glass EE 140 Wide grid bar IG/WD/EE 001 0.33 0.33 0.17 0.17 0.23 0.23 RC Wood Radius Casement Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 001 033 0.33 0.18 0.19 0.25 0.26 RC Wood Radius Casement Window Insulated glass EE 140 IG/EE 001 033 0.33 0.2 0.2 0.28 0.28 French Casement Windows OFC Wood French Casement Window Single glaze Clear Wide grid bar SG/WD 001 0:92 0.95 0.52 0.54 0.52 0.56 DFC Wood French Casement Window Single glaze Clear Narrow grid bar SG/NR 001 3.9 0.94 0.57 0.58 0.58 0.62 FC Wood French Casement Window Single glaze Clear Wide grid bar SG/WD 001 092 0.95 0.52 0.54 0.52 0.56 FC Wood French Casement Window Single glaze Clear Narrow grid bar SG/NR 001 3.9 0.94 0.57 0.58 0.58 0.62 FC Wood French Casement Window Single glaze Clear SG 001 0.92 0.96 0.62 0.63 0.63 0.67 FC Wood French Casement Window Insulated glass Clear Wide grid bar IG/WD 001 C.46 0.47 0.47 0.46 0.47 0.5 FC Wood French Casement Window Insulated glass Clear Narrow grid bar IG/NR 001 C.46 0.47 0.51 0.5 0.52 0.55 FC Wood French Casement Window Insulated glass Clear IG 001 C.46ry 0.47 0.50 0.55 0.57 0.6 FC Wood French Casement Window Insulated glass LoE2 Wide grid bar IG/WD/LE 001 C.33 0.32 0.26 0.27 0.42 0.44 K, Wood French Casement Window Insulated glass LoE2 Narrow and bar IG/NR/LE 001 C.33 0.32 0.28 0.29 0.46 0.48 FC Wood French Casement Window Insulated glass LoE2+ IG/LE 001 C.3D 0.32 0:31r 0.31 0.51 0.53 DFC Wood French Casement Window Insulated glass Clear Wide grid bar IDL 001 C.48 0.48 0.47 0.46 0.47 0.5 DFC Wood Frencn Casement Window Insulated glass LoE2 Wide and bar IDL/LE 001 C.37 0.36 0.26 0.27 0.42 0.44 DFC Wood French CasementWindow Insulated glass EE 140 Wide avid bar IDUEE 001 C37 0.37 0.17 0.17 0.23 0.23 FC Wood French Casement Window Insulated glass EE 140 Wide grid bar IG/WD/EE 001 C.33 0.33 0.17 0.17 0.23 0.23 ' FC Wogd French Casement Window Insulated glass EE 140 Narrow and bar IG/NR/EE 001 C-33 0.33 0.18 0.19 0.25 0.26 FC Wood French Casement Window Insulated glass EE 140 IG/EE 001 C.33 0.33 0.2 0.2 0.28 0.28 Awning Windows DA Wood Awning Window Single glaze Clear ;Nide grid bar SG/WD 002 C.88 0.93 0.5 0.53 0.5 0.55 ' DA Wood Awmno Window Single olaze Clear Narrow grid bar SG/NR 002 0.9 0.95 0.55 0.58 0.55 0.61 WA Wood Awmno Winnow Single glaze Clear Wide and bar SG/WD 002 C.88 0.93 0.51 0.53 0.5 0.55 WA Wood Awning Winaow Sinaie Glaze Clear Narrow and bar SG/NR 002 0.9 0.95 0.55 0.58 0.55 0.61 Page t of 10 WA Wood Avming Window Single glaze Clear Glazing SG 002 U -value 0.9 SHGC V, WA bVocd Avjning Window insulated glass Clear Wide grid bar IG/WD 002 0.46 0.95 0.47 0.6 0.45 0.62 0.46 0.61 0.66 WA Wood Awning Window Insulated glass Clear Narrow grid bar IG/NR 002 0.46 0.47 0.49 0.5 0.45 0.49 Wood Awning Window insulated glass Clear IG 002 0.46 0.47 0.53 � 0.54 0.5 054 WA WA Wood Awning Window Insulated glass LoE2 'elide grid 'oar IG/WD/LE 002 0.33 0.32 US 0.27 0.55 0.4 0.59 WA VJcgd Awning Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 002 0.33 0.32 0.27 0.29 0.44 0.43 WA Wocd Awning Window Insulated glass LoE2 IG/LE 002 0.33: 0.32 0.29' 0.31 0.48 0.48 DA Wood Awning Window Insulated glass Clear Wide grid bar IDL 002 0.47 0.49 0.45 0.46 0.45 0.52 DA Wood Awnino Window Insulated glass LoE2 Wide grid bar IDL/LE 002 0.37 0.36 0.25 0.27 0.4 0.49 DA Wood Awning Window Insulated glass EE 140 Wide grid bar IDL/EE 002 0.37 0.37 0.16 0.17 0.22 0.43 WA Wood Awning Window Insulated glass EE 140 Wide grid bar IG/WD/EE 002 0.33 0.33 0.16 0.17 0.22 0.23 WA Wood Awning Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 002 0.33 0.33 0.18 0.18 0.24 0.23 WA Wood Awning Window Insulated glass EE 140 IG/EE 002 0.33 0.33 0.19 0.2 0.27 0.25 0.28 Casement Picture Windows DCP Wood Casement Picture Window Single glaze Clear Wide grid bar SG/WD 003 0.95 0.97 0.56 0.55 0.57 0.58 DCP Wood Casement Picture Window Single glaze Clear Narrow grid bar SG/NR 003 0.97 1 0.63 0.62 0.64 0.65 WCP Wood Casement Picture Window Single glaze Clear Wide grid bar SG/WD 003 0.95 0.97 0.56 0.55 0.57 0.58 WCP Wood Casement Picture Window Single glaze Clear Narrow grid bar SG/NR 003 0.97 1 0.63 0.62 0.64 0.65 WCP Wood Casement Picture Window Single glaze Clear SG 003 0.98 1 0.69 0.68 0.71 0.73 WCP Wood Casement Picture Window Insulated.g(ass Clear Wide grid bar IG/WD 003 0.47 0.48 0.5 0.48 0.51 0.52 WCP Wood Casement Picture Window Insulated glass Clear Narrow grid bar IG/NR 003 0.47 0.48 0.56 0.53 0.58 0.58 WCP Wood Casement Picture Window Insulated glass Clear IG 003 0.47) 0.48 0.61' 0.59 0.64 0.65 WCP Wood Casement Picture Window Insulated glass LoE2 Wide grid bar IG/WD/LE 003 0.32 0.32 0.28 0.28 0.45 0.46 WCP Wood Casement Picture Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 003 0.32 0.32 0.31 0.31 0.51 0.51 WCP Wood Casement Picture Window Insulated glass LoE2' IG/LE 003 0.32 0.32 0.31? 0.34 0.57 0.57 DCP Wood Casement Picture Window Insulated glass Clear Wide grid bar IDL 003 0.49 0.5 0.5 0.48 0.51 0.52 DCP Wood Casement Picture Window Insulated glass LoE2 Wide grid bar IDL/LE 003 0.37 0.37 0.28 0.28 0.45 0.46 DCP Wood Casement Picture Window . Insulated glass EE 140 Wide grid bar IDL/EE 003 0.37 0.37 0.18 0.18 0.25 0.24 WCP Wood Casement Picture Window Insulated glass EE 140 Wide grid bar IG/WD/EE 003 0.33 0.32 0.18 0.18 0.25 0.24 WCP Wood Casement Picture Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 003 0.33 0.32 0.2 0.19 0.28 0.27 WCP Wood Casement Picture Window Insulated glass EE 140 IG/EE 003 0.33 0.32 0.21 0.21 0.31 0.31 Radius Picture Windows DRP Wood Casement Radius Picture Window Single glaze Clear Wide grid bar SG/WD 003 0.95 0.97 0.56 0.55 0.57 0.58 DRP Wood Casement Radius Picture Window Single glaze Clear Narrow grid bar SG/NR 003 0.97 1 0.63 0.62 0.64 0.65 RCP Wood Casement Radius Picture Window Single glaze Clear Wide grid bar SG/WD 003 0.95 0.97 0.57 0.56 0.57 0.58 RCP Wood Casement Radius Picture Window Single glaze Clear Narrow grid bar SG/NR 003 0.97 1 0.63 0.62 0.64 0.65 RCP Wood Casement Radius Picture Window Single glaze Clear SG 003 0.98 1 0.69 0.68 0.71 0.73 RCP Wood Casement Radius Picture Window Insulated glass Clear Wide grid bar IG/WD 003 0.47 0.48 0.5 0.48 0.51 0.52 RCP Wood Casement Radius Picture Window Insulated glass Clear Narrow grid bar IG/NR 003 0.47 0.48 0.56 0.53 0.58 0.58 RCP Wood Casement Radius Picture Window Insulated glass Clean IG 003 0:477 0.48. 0.614 0.59 0.64 0.65 RCP Wood Casement Radius Picture Window Insulated glass LoE2 Wide grid bar IG/WD/LE 003 022 0.32 0.28 0.28 0.45 0.46 RCP Wood Casement Radius Picture Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 003 0.32 0.32 0.31 0.31 0.51 0.51 RCP Wood Casement Radius Picture Window Insulated glass LoE2 IG/LE 003 0.35 0.32 0.33? 0.34 0.57 0.57 DRP Wood Casement Radius Picture Window Insulated glass Clear Wide grid bar IDL 003 0.49 0.5 0.5 0.48 0.51 0.52 DRP Wood Casement Radius Picture Window Insulated glass LoE2 Wide grid bar IDL/LE 003 0.37 0.37 0.28 0.28 0.45 0.46 DRP Wood Casement Radius Picture Window Insulated glass EE 140 Wide grid bar IDL/EE 003 0.37 0.37 0.18 0.18 0.25 0.24 RCP Wood Casement Radius Picture Window Insulated glass EE 140 Wide grid bar IG/WD/EE 003 0.33 0.32 0.18 0.18 0.25 0.24 RCP Wood Casement Radius Picture Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 003 0.33 0.32 0.2 0.19 0.28 0.27 RCP Wood Casement Radius Picture Window Insulated glass EE 140 IG/EE 003 0.33 0.32 0.21 0.21 0.31 0.31 Direct Glaze Windows DDG Wood Direct Glaze Window Single glaze Clear Wide grid bar 5G/WD 004 1.06 1.07 0.65 0.62 0.66 0.65 DDG Wood Direct Glaze Window Single glaze Clear Narrow grid bar SG/NR 004 1.06 1.07 0.71 0.68 0.74 0.73 DG Wood Direct Glaze Window Single glaze Clear Wide grid bar SG/WD 004 1.06 1.07 0.65 0.62 0.66 0.65 DG Wood Direct Glaze Window Single glaze Clear Narrow grid bar SG/NR 004 1.06 1.07 0.71 0.68 0.74 0.73 DG Wood Direct Glaze Window Single glaze Clear SG 004 1.06 1.07 0.78 0.75 0.81 0.81 DG Wood Direct Glaze Window Single glaze Clear IG/WD 004 0.49 0.49 0.58 0.53 0.6 0.58 DG Wood Direct Glaze Window Insulated glass Clear Wide grid bar IG/NR 004 0.49 0.49 0.63 0.59 0.67 0.65 DG Wood Direct Glaze Window Insulated glass Clear.:. Narrow grid bar IG 004 0.49'- 0.49 0.7= 0.65 0.74 0.72 DG Wood Direct Glaze Window Insulated glass Clear IG/WD/LE 004 0.32:.: 0.31 0.32'! 0.31 0.53 0.51 DG Wood Direct Glaze Window Insulated glass LoE2 Wide grid bar IG/NR/LE 004 0.32 0.31 0.34 0.34 0.59 0.57 DG Wood Direct Glaze Window Insulated glass LoE2 Narrow grid bar IG/LE 004 0:32.`3 0.31 0.38-•z, 0.37 0.65 0.64 DDG Wood Direct Glaze Window Insulated glass LoEZ-"�; IDL 004 MP` 0.51 068 : 0.53 0.6 0.58 DDG Wood Direct Glaze Window Insulated glass Clear Wide grid bar IDL/LE 004 0.37 0.37 0.32 0.31 0.53 0.51 DDG Wood Direct Glaze Window Insulated glass LoE2 Wide grid bar IDL/EE 004 0.37 0.37 0.2 0.19 0.29 0.27 DG Wood Direct Glaze Window Insulated glass EE 140 Wide grid bar IG/WD/EE 004 0.32 0.32 0.2 0.19 0.29 0.27 DG Wood Direct Glaze Window Insulated glass EE 140 Wide grid bar IG/NR/EE 004 0.32 0.32 0.22 0.21 0.32 0.31 DG Wood Direct Glaze Window insulated plass EE 140 Narrow grid bar IG/EE 004 0.32 0.32 0.23 0.23 0.36 0.34 DE� Wood Direct Glaze Window Insulated glass EE 140 SG/WD 004 1.06 1.07 0.65 0.62 0.66 0.65 Horizontal Sliding Windows DS Wood Horizontal Sliding Window Single glaze Clear Wide grid bar SG/WD 017 0.98 1 0.55 0.56 0.55 0.58 DS Wood Horizontal Sliding Window Single glaze Clear Narrow grid bar SG/NR 017 0.98 1 0.61 0.61 0.61 0.65 WS Wood Horizontal Sliding Window Single glaze Clear Wide grid bar SG/WD 017 0.98 1 0.55 0.56 0.55 0.58 WS Wood Horizontal Sliding Window Single glaze Clear Narrow grid bar SG/NR 017 0.98 1 0.61 0.61 0.61 0.65 WS Wood Horizontal Slidino Window Single glaze Clear SG 017 0.98 1 0.67 0.67 0.68 0.71 WS 'Hood Horizontal Sliding Window Insulated glass Clear Wide grid bar !G/WD 017 0.49 0.49 0.49 0.48 0.49 0.51 WS Wood Horizontal Sliding Window insulated glass Clear Narrow and bar iGiNR 017 0.49 0.49 0.54 0.53 0.55 0.57 WS 'Wood Horizontal Sliding Window Insulated glass Clear IG 017 0.491;; 0.49 MV: 0.58 0.62 0.63 WS Wood Horizontal Slidino Window insulated glass LoE2 Wide and bar IG/WD/LE 017 0.35 0.34 0.27 0.28 0.44 0.46 WS Wood Horizontal Slidino Window insulates class LoE2 Marrow grid 'oar IGiNR/LE 017 0.35 0.34 0.3 0.31 0.49 0.51 %IVS bv000 Horizontal Sliding Window Insulated glass LoE2 IGi LE 017 0.35 0.34 0.33' 0.33 0.54 0.56 Paoe 2) of 10 Paae 3 of 10 Glazing U -value SHGC V, 'IS Wood Horizontal Sliding Window Insulated class EE 140 Wide grid bar IG/WD/E"t 017 0.35 0.34 0.18 0.18 0.24 0.24 PIS Wood Horizontal Sliding Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 017 0.35 0.34 0.19 0.19 0.27 0.27 WS Wood Horizontal Sliding Window Insulated glass EE 140 IGJEE 017 0.35 0.34 0.21 0.21 0.3 0.3 DS :"lood Horizontal Sliding Window Insulated glass Clear Wide and bar IDL 017 0.5 0.51 0.49 0.48 0.49 0.51 DS `:Mood Horizontai Sliding Window Insulated glass LoE2 Wide grid bar IDL/LE 017 0.39 0.38 0.27 0.28 0.44 0.46 DS Wood Horizontal Slidino Window Insulated glass EE 140 Wide and bar. IDL/EE 017 0.39 0.39 0.18 0.18 0.24 0.24 Double Hung Windows DDH Wood Double Hung Window Single_ glaze Clear Wide grid 'oar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 DDH Woca Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 WDH Wood Double Hung Window Single glaze Clear Wide grid 'oar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 WDH Wood Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 WDH Wood Double Hung Window Single glaze Clear SG 015 0.97 1 0.66 0.66 0.67 0.7 WDH Wood Double Hung Window Insulated glass Clear Wide grid bar IG/WD 015 0.49 0.49 0.48 0.47 0.48 0.51 WDH Wood Double Hung Window Irsulated glass Clear Narrow grid bar IG/NR 015 0.49 0.49 0.53 0.52 0.54 0.56 WDH Wood Double Hung Window Insulated glass Clear IG 015 0.49 = 0.49 0.58 0.57 0.61 0.62 WDH Wood Double Hung Window Insulated glass LoE2 Wide grid bar IG/WD/LE 015 0.34 0.34 0.27 0.28 0.43 0.45 WDH Wood Double Hung Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 015 0.34 0.34 0.29 0.3 0.48 0.5 WDH Wood Double Hung Window Insulated glass LoE2 IG/LE 015 0.34 0.34 0.32 0.33 0.53 0.55 WDH Wood Double Hung Window Insulated glass EE 140 Wide grid bar IG/WD/EE 015 0.35 0.34 0.18 0.18 0.24 0.24 WDH Wood Double Hung Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 015 0.35 0.34 0.19 0.19 0.26 0.27 WDH Wood Double Hung Window Insulated glass EE 140 IG/EE 015 0.35 0.34 0.21 0.21 0.29 0.29 DDH Wood Double Hung Window Insulated glass Gear Wide grid bar IDL 015 0.51 0.51 0.48 0.47 0.48 0.51 DDH Wood Double Hung Window Insuiated glass LoE2 Wide grid bar IDL/LE 015 0.39 0.39 0.27 0.28 0.43 0.45 DDH Wood Double Hung Window Insulated glass EE 140 Wide grid bar IDL/EE 015 0.39 0.39 0.18 0.18 0.24 0.24 Radius Double Hung Windows DRD Wood Radius Double Hung Window Single glaze Clear Wide grid bar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 DRD Wood Radius Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 RDH Wood Radius Double Hung Window Single glaze Clear Wide grid bar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 RDH Wgod Radius Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 RDH Wood Radius Double Hung Window Single glaze Clear SG 015 0.97 1 0.66 0.66 0.67 0.7 RDH Wood Radius Double Hung Window Insulated glass Clear Wide grid bar IG/WD 015 0.49 0.49 0.48 0.47 0.48 0.51 RDH Wood Radius Double Hung Window Insulated glass Clear Narrow grid bar IG/NR 015 0.49 0.49 0.53 0.52 0.54 0.56 RDH Wood Radius Double Hung Window Insulated glass Clear IG 015 0.49 0.49 0.58 0.57 0.61 0.62 RDH Wood Radius Double Hung Window Insulated glass LoE2 Wide grid bar IG/WD/LE 015 0.34 0.34 0.27 0.28 0.43 0.45 RDH Wood Radius Double Hung Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 015 0.34 0.34 0.29 0.3 0.48 0.5 RDH Wood Radius Double Hung Window Insulated glass LoE2 IG/LE 015 0.34 0.34 0.32 0.33 0.53 0.55 RDH Wood Radius Double Hung Window Insulated glass EE 140 Wide grid bar IG/WD/EE 015 0.35 0.34 0.18 0.18 0.24 0.24 RDH Wood Radius Double Hung Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 015 0.35 0.34 0.19 0.19 0.26 0.27 RDH Wood Radius Double Hung Window Insulated glass EE 140 IG/EE 015 0.35 0.34 0.21 0.21 0.29 0.29 DRD Wood Radius Double Hung Window Insulated glass Clear Wide grid bar IDL 015 0.51 0.51 0.48 0.47 0.48 0.51 DRD Wood Radius Double Hung Window Insulated glass LoE2 Wide grid bar IDL/LE 015 0.39 0.39 0.27 0.28 0.43 0.45 DRD Wood Radius Double Hung Window Insulated glass EE 140 Wide grid bar IDL/EE 015 0.39 0.39 0.18 0.18 0.24 0.24 Cottage Double Hung Windows DCDH Wood Cottage Double Hung Window Single glaze Clear Wide grid bar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 DCDH Wood Cottage Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 CDH Wood Cottage Double Hung Window Single glaze Clear Wide grid bar SG/WD 015 0.97 1 0.54 0.55 0.54 0.57 CDH Wood Cottage Double Hung Window Single glaze Clear Narrow grid bar SG/NR 015 0.97 1 0.6 0.6 0.6 0.64 CDH Wood Cottage Double Hung Window Single glaze Clear SG 015 0.97 1 0.66 0.66 0.67 0.7 CDH Wood Cottage Double Hung Window Insulated glass Clear Wide grid bar IG/WD 015 0.49 0.49 0.48 0.47 0.48 0.51 CDH Wood Cottage Double Hung Window Insulated glass Clear Narrow grid bar IG/NR 015 0.49 0.49 0.53 0.52 0.54 0.56 CDH Wood Cottage Double Hung Window Insulated glass Clear IG 015 0.49 0.49 0.58 0.57 0.61 0.62 CDH Wood Cottage Double Hung Window Insulated glass LoE2 Wide grid bar IG/WD/LE 015 0.34 0.34 0.27 0.28 0.43 0.45 CDH Wood Cottage Double Hung Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 015 0.34 0.34 0.29 0.3 0.48 0.5 CDH Wood Cottage Double Hung Window Insulated glass LoE2 IG/LE 015 0.34 0.34 0.32 0.33 0.53 0.55 CDH Wood Cottage Double Hung Window Insulated glass EE 140 Wide grid bar IG/WD/EE 015 0.35 0.34 0.18 0.18 0.24 0.24 CDH Wood Cottage Double Hung Window Insulated glass EE 140 Narrow grid bar IG/NR/EE 015 0.35 0.34 0.19 0.19 0.26 0.27 CDH Wood Cottage Double Hung Window Insulated glass EE 140 IG/EE 015 0.35 0.34 0.21 0.21 0.29 0.29 DCDH Wood Cottage Double Hung Window Insulated glass Clear Wide grid bar IDL 015 0.51 0.51 0.48 0.47 0.48 0.51 DCDH Wood Cottage Double Hung Window Insulated glass LoE2 Wide grid bar IDL./LE 015 0.39 0.39 0.27 0.28 0.43 0.45 DCDH Wood Cottage Double Hung Window Insulated glass EE 140 Wide grid bar IDL/EE 015 0.39 0.39 0.18 0.18 0.24 0.24 Double Hung Picture Windows DPU Wood Double Hung Picture Window Single glaze Clear Wide grid bar SG/WD 016 0.98 1 0.56 0.55 0.57 0.58 DPU Wood Double Hung Picture Window Single glaze Clear Narrow grid bar SG/NR 016 0.98 1 0.62 0.61 0.63 0.65 WPU Wood Double Hung Picture Window Single glaze Clear Wide grid bar SG/WD 016 0.98 1 0.56 0.55 0.57 0.58 WPU Wood Double Hung Picture Window Single glaze Clear Narrow grid bar SG/NR 016 0.98 1 0.62 0.61 0.63 0.65 WPU Wood Double Hung Picture Window Single glaze Clear SG 016 0.98 1 0.69 0.68 0.71 0.72 WPU Wood Double Hung Picture Window Insulated glass Clear Wide grid bar IG/WD 016 0.48 0.48 0.5 0.47 0.51 0.51 WPI Wood Double Hung Picture Window Insulated glass Clear Narrow grid bar IG/NR 016 0.48 0.48 0.56 0.53 0.57 0.58 WPU Wood Double Hung Picture Window Insulated glass Clear IG 016 0:48 0.48 0.6V 0.58 0.64 0.64 WPU Wood Double Hung Picture Window Insulated glass LoE2 Wide grid bar IG/WD/LE 016 0.33 0.32 0.28 0.28 0.45 0.45 WPU Wood Double Hung Picture Window Insulated glass LoE2 Narrow grid bar IG/NR/LE 016 0.33 0.32 0.31 0.3 0.51 0.51 WPU Wood Double Hung Picture Window Insulated glass LoE2 IG/LE 016 0.337 0.32 0.34 0.33 0.56 0.57 WPU Wood Double Hung Picture Window Insulated glass EE 140 Wide and bar IG/WD/EE 016 0.33 0.33 0.18 0.18 0.25 0.24 WPU Wood Double Hung Picture Window Insulated class EE 140 Narrow grid bar IG/NR/EE 016 0.33 0.33 0.2 0.19 0.28 0.27 WPU bVood Double Hung Picture Window Insulated glass EE 140 IG/EE 016 0.33 0.33 0.21 0.21 0.31 0.3 DPU Wood Douole Hung Picture'Window Insulated class Clear Wide grid bar IDL 016 0.5 0.5 0.5 0.47 0.51 0.51 DPU Wood Dougle Hung Picture Window Insulated glass LoE2 Wide and bar IDL/LE 016 0.38 0.28 0.28 0.28 0.45 0.45 DPU Wooc Double Hung Picture Window Insulated glass EE 140 Wide grid bar IDUEE 016 0.38 0.38 O.A 0.18 0.25 0.24 Sliding Patio Doors DPD Voo�'Siiding Patio Door Single Glaze !Vide grid bar SG/WD 006 0.88 0.89 0.46 0.45 0.45 0.45 Paae 3 of 10 A • Glazing U•value SHGC V, IS Wood Inswing Door Sidelite Insulated glass LoE2 Narrow grid bar IG/NR/LE 010 0.36 0.36 0.15 0.15 0.19 0.18 IS Wood inswing Door Sidelite Insulated glass LoE2 IG/LE 010 0.36 0.36 0.16 0.16 0.2 0.19 IS Wood inswing Door Sidelite Insulated glass EE 140 Wide grid bar IG/WD/EE 010 0.35 0.36 0.11 0.11 0.1 IS Wood Inswing Door Sidelite Insulated glass EE 140 Narrow grid bar IG/NR/EE 010 0.35 0.36 0.11 0.11 0.1 0.09 IS Wood Inswing Door Sidelite Insuiated glass EE 140 IG/EE 010 0.36 0.36 0.12 0.11 0.11 0.1 0.1 DIS Wood Inswing Door Sidelite Insulated glass Clear Vide grid bar IDL 010 0.42 0.42 0.24 0.22 0.2 0.19 DIS Wood Inswing Door Sidelite Insulated class LoE2 Wide grid bar IDULE 010 0.37 0.37 0.15 0.14 0.18 0.1 DIS Wood Inswing Door Sidelite Insulated glass EE 140 Wide grid bar IDL/EE 010 0.37 0.37 0.11 0.11 0.1 0.09 Inswing Door Transoms (same as outswing) DIT Wood Swing Door Transom Single glaze Clear Wide grid bar SG/WD 011 0.69 0.74 0.294 0.32 0.262 0.305 DIT Wood Swing Door Transom Single glaze Clear Narrow grid bar SG/NR 011 0.7 0.75 0.338 0.371 0.311 0.363 IT Wood Swing Door Transom Single glaze Clear Wide grid bar SG/WD 011 0.69 0.74 0.294 0.32 0.262 0.305 IT Wood Swing Door Transom Single glaze Clear Narrow grid bar SG/NR 011 0.7' 0.75 0.338 0.371 0.311 0.363 IT Wood Swing Door Transom Single glaze Clear SG 011 0.7 0.76 0.385 0.425 0.364 0.426 IT Wood Swing Door Transom Insulated glass Cfear Wide grid bar IG/WD 011 0.43 0.44 0.266 0.281 0.237 0.27 1T Wood Swing Door Transom Insulated glass Clear Narrow grid bar IG/NR 011 0.43 0.44 0.304 0.323 0.281 0.322 IT Wood Swing Door Transom Insulated glass Clear IG 011 0.43 0.44 0.35 0.37 0.33 0.38 IT Wood Swing Door Transom Insulated glass LoE2 Wide grid bar IG/WD/LE 011 0.35 0.35 0.163 0.176 0.209 0.239 IT Wood Swing Door Transom Insulated glass LoE2 Narrow grid bar IG/NR/LE 011 0.35 0.35 0.182 0.198 0.248 0.285 IT Wood Swing Door Transom Insulated glass LoE2 IG/LE 011 0.35 0.35 0.2 0.22 0.29 0.33 IT Wood Swing Door Transom Insulated glass EE 140 Wide grid bar IG/WD/EE 011 0.36 0.35 0.117 0.123 0.116 0.127 IT Wood Swing Door Transom Insulated glass EE 140 Narrow grid bar IG/NREE 011 0.36 0.35 0.128 0.136 0.137 0.152 IT Wood Swing Door Transom Insulated glass EE 140 IG/EE 011 0.36 0.35 0.14 0.149 0.16 0.178 DIT Wood Swing Door Transom Insulated glass Clear Wide grid bar IDL 011 0.43 0.44 0.266 0.281 0.237 0.27 DIT Wood Swing Door Transom insulated glass LoE2 Wide grid bar IDL/LE 011 0.37 0.36 0.163 0.176 0.209 0.239 DIT Wood Swing Door Transom Insulated glass EE 140 Wide grid bar IDL/EE 011 0.37 0.37 0.117 0.123 0.116 0.127 Sliding Patio Door Transoms DPT Wood Sliding Patio Door Transom Single glaze Clear Wide grid bar SG/WD 008 0.?1 0.76 0.294 0.32 0.26 0.302 DPT Wood Sliding Patio Door Transom Single glaze Clear Narrow grid bar SG/NR 008 0.72 0.77 0.338 0.371 0.309 0.361 PT Wood Sliding Patio Door Transom Single glaze Clear Wide grid bar SG/WD 008 0.71 0.76 0.294 0.32 0.26 0.302 PT Wood Sliding Patio Door Transom Single glaze Clear Narrow grid bar SG/NR 008 0.72 0.77 0.338 0.371 0.309 0.361 PT Wood Sliding Patio Door Transom Single glaze Gear SG 008 0.72 0.77 0.385 0.425 0.361 0.424 PT Wood Sliding Patio Door Transom Insulated glass Clear Wide grid bar IG/WD 008 0.44 0.45 0.266 0.281 0.235 0.268 PT Wood Sliding Patio Door Transom Insulated glass Clear Narrow grid bar IG/NR 008 0.44 0.45 '0.304 0.324 0.279 0.32 PT Wood Sliding Patio Door Transom Insulated glass Clear IG 008 0.44 0.45 0.346 0.37 0.327 0.376 PT Wood Sliding Patio Door Transom Insulated glass LoE2 Wide grid bar IG/WD/LE 008 0.37 0.36 0.164 0.177 0.207 0.237 PT Wood Sliding Patio Door Transom Insulated glass LoE2 Narrow grid bar IG/NR/LE 008 0.37 0.36 0.183 0.199 0.246 0.283 PT Wood Sliding Patio Door Transom Insulated glass LoE2 IG/LE 008 0.37 0.36 0.204 0.224 0.288 0.333 PT Wood Sliding Patio Door Transom Insulated glass EE 140 Wide grid bar IG/WD/EE 008 0.37 0.36 0.119 0.124 0.114 0.126 PT Wood Sliding Patio Door Transom Insulated glass EE 140 Narrow grid bar IG/NR/EE 008 037 0.36 0.13 0.137 0.136 0.151 PT Wood Sliding Patio Door Transom Insulated glass EE 140 IG/EE 008 0.37 0.36 0.141 0.15 0.159 0.177 DPT Wood Sliding Patio Door Transom Insulated glass Clear Wide grid bar IDL 008 0.45 0.46 0.266 0.281 0.235 0.268 DPT Wood Sliding Patio Door Transom Insulated glass LoE2 Wide grid bar IDL/LE 008 0.38 0.37 0.164 0.177 0.207 0.237 DPT Wood Sliding Patio Door Transom Insulated glass EE 140 Wide grid bar IDL/EE 008 0.38 0.37 0.119 0.124 0.114 0.126 Outswing Doors DOD Wood Outswing Door Single glaze Clear Wide grid bar SG/WD 012 0.84 0.84 0.44 0.42 0.43 0.42 DOD Wood Outswing Door Single glaze Clear Narrow grid bar SG/NR 012 0.84 0.84 0.49 0.47 0.48 0.47 OD Wood Outswing Door Single glaze Clear Wide grid bar SG/WD 012 0.84 0.84 0.44 0.42 0.43 0.42 OD Wood Outswing Door Single glaze Clear Narrow grid bar SG/NR 012 0.84 0.84 0.49 0.47 0.48 0.47 OD Wood Outswing Door Single glaze Clear SG 012 0.84 0.84 0.54 0.52 0.54 0.43 OD Wood Outswing Door Insulated glass Clear Wide grid bar IG/WD 012 0.46 0.46 0.4 0.37 0.39 0.37 0D Wood Outswing Door Insulated glass Clear Narrow grid bar IG/NR 012 0.46 0.46 0.44 0.41 0.44 0.42 OD Wood Outswing Door Insulated glass Clem IG 012 U.46=wl 0.46 0.481 0.45 0.49 0.47 OD Wood Outswing Door Insulated glass LoE2 Wide grid bar IG/WD/LE 012 0.35 0.35 0.23 0.22 0.34 0.33 OD Wood Outswing Door Insulated glass LoE2 Narrow grid bar IG/NR/LE 012 0.35 0.35 0.25 0.24 0.38 0.37 OD Wood Outswing Door Insulated glass LoE21 IG/LE 012 0.35p 0.35 0.27.1 0.26 0.43 0.42 OD Wood Outswing Door Insulated glass EE 140 Wide grid bar IG/WD/EE 012 C.35 0.35 0.15 0.15 0.19 0.18 OD Wood Outswing Door Insulated glass EE 140 Narrow grid bar IG/NR/EE 012 0.35 0.35 0.17 0.16 0.21 0.2 OD Wood Outswing Door Insulated glass EE 140 IG/EE 012 0.35 0.35 0.18 0.17 0.24 0.22 DOD Wood Outswing Door Insulated glass Clear Wide grid bar IDL 012 0.48 0.48 0.4 0.37 0.39 0.37 DOD Wood Outswing Door Insulated glass LoE2 Wide grid bar IDULE 012 0.39 0.39 0.23 0.22 0.34 0.33 DOD Wood Outswing Door Insulated glass EE 140 Wide grid bar IDL/EE 012 0.39 0.39 0.15 0.15 0.19 0.18 Radius Outswing Doors DROD Wood Radius Outswing Door Single glaze Clear Wide grid bar SG/WD 012 0.84 0.84 0.44 0.42 0.43 0.42 DROD Wood Radius Outswing Door Single glaze Clear Narrow grid bar SG/NR 012 0.84 0.84 0.49. 0.47 0.48 0.47 ROD Wood Radius Outswing Door Single glaze Clear Wide grid bar SG/WD 012 0.84 0.84 0.44 0.42 0.43 0.42 ROD Wood Radius Outswing Door Single glaze Clear Narrow grid bar SG/NR 012 0.84 0.84 0.49 0.47 0.48 0.47 ROD Wooa Radius Outswing Door Single glaze Clear SG 012 0.84 0.84 0.54 0.52 0.54 0.43 RBD W000 Radius Outswing Door Insulated glass Clear Wide grid bar IG/WD 012 0.46 0.46 0.4 0.37 0.39 0.37 ROD Wood Radius Outswing Door Insulated glass Clear Narrow grid bar IG/NR 012 0.46 0.46 0.44 0.41 0.44 0.42 ROD Wood Radius OuLswing Door Insulated glass Clear IG 012 0.46 0.46 0.48 0.45 0.49 0.47 ROD Wood Radius Outswing Door Insulated glass LoE2 Wide grid bar IG/WD/LE 012 0.35 0.35 0.23 0.22 0.34 0.33 ROD Wood Radius Outswing Door Insulated glass LoE2 Narrow grid bar IG/NR/LE 012 0.35 0.35 0.25 0.24 0.38 0.37 ROD Wood Radius Outswina Door Insulated glass LoE2 IG/LE 012 0.35 0.35 0.27 0.26 0.43 0.42 ROD Wood Radius Outswino Door Insulated glass EE 140 Wide grid bar IG/WD/EE 012 3.35 0.35 0.15 0.15 0.19 0.18 ROD Wood Radius Outswing Door insulated glass EE 140 Narrow grid bar IG/NR/EE 012 3.35 0.35 0.17 0.16 0.21 0.2 ROD %Vooa Ragius Outswing Door Insulated glass EE 140 IG/EE 012 3.35 0.35 0.18 0.17 0.24 0.22 DROD 1Vood Radius Outswino Door Insulated plass Clear `Nide grid bar IDL 012 0.48 0.48 0.4 0.37 0.39 0.37 DROD W000 Radius Outswina Door insulated glass LoE2 Wide grid bar IDVLE 012 0.39 0.39 0.23 0.22 0.34 0.33 DROD W000 Raoius Outswino Door insuiateo glass EE 140 Wide grid bar IDL/EE 012 0.39 0.39 0.15 0.15 0.19 0.18 Page 4- of 10 Outswing Door Sidelights DOS Wood Outswing Door Sidelite DOS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS 'blood Outswing Door Sidelite 05 `good Outswing Door Sidelite OS Wocd Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite OS Wood Outswing Door Sidelite DOS Wood Outswing Door Sidelite DOS Wood Outswing Door Sidelite DOS Wood Outswing Door Sidelite Outswing Door Transoms (same as inswing) DOT Wood Swing Door Transom 0.28 DOT Wood Swing Door Transom o.24 OT Wood Swing Door Transom IG/WD OT Wood Swing Door Transom 0.42 OT Wood Swing Door Transom 0.19 OT Wood Swing Door Transom Narrow grid bar OT Wood Swing Door Transom 0.42 OT Wood Swing Door Transom 0.23 OT Wood Swing Door Transom Insulated glass Clear OT Wood Swing Door Transom 013 OT Wood Swing Door Transom 0.25 OT Wood Swing Door Transom 0.21 OT Wood Swing Door Transom IG/WD/LE OT Wood Swing Door Transom 0.38 DOT Wood Swing Door Transom 0.17 DOT Wood Swing Door Transom Narrow grid bar DOT Wood Swing Door Transom 0.38 Clad Casement Windows 0.15 C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window C -WC Clad Wood Casement Window Clad Casement Half Round Windows C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window C -CH Clad Wood Casement Half Round Window Clad Radius Casement Windows Wide grid bar C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window C -RC Clad Wood Radius Casement Window Clad French Casement Windows 0.363 C -FC Clad W000 French Casement Window C -FC Clad Wood French Casement Window C -FC Clad Wood French Casement Window C -FC Clad Wood French Casement Window Glazing U -value SHGC Single glaze Clear Wide grid bar - SG/WD 013 0.6 0.6 0.26 0.24 0.21 0.21 Single glaze Clear Narrow grid bar SG/NR 013 0.61 0.61 0.27 0.26 0.23 0.22 Single glaze Clear Wide grid bar SG/WD 013 0.6 0.6 0.26 0.24 0.21 o.21 Single glaze Clear Narrow grid bar SG/NR 013 0.61 0.61 0.27 0.26 0.23 0.22 Single glaze Clear SG 013 0.61 0.61 0.28 0.27 0.24 o.24 Insulated glass Clear Wide grid bar IG/WD 013 0.42 0.42 0.23 0.22 0.19 0.19 Insulated glass Clear Narrow grid bar IG/NR 013 0.42 0.42 0.24 0.23 0.21 0.2 Insulated glass Clear IG 013 0.42' 0.42 0.25 0.24 0.22 0.21 Insulated glass LoE2 Wide grid bar IG/WD/LE 013 0.38 0.38 0.15 0.14 0.17 0.16 Insulated glass LoE2 Narrow grid bar IG/NR/LE 013 0.38 0.38 0.15 0.15 0.18 0.17 Insulated glass LOEZ, IG/LE 013 0.38; 0.38 0.16' 0.15 0.19 0.18 Insulated glass EE 140 Wide grid bar IG/WD/EE 013 0.38 0.38 0.11 0.11 0.09 0.09 Insulated glass EE 140 Narrow grid bar IG/NR/EE 013 0.38 0.38 0.11 0.11 0.1 0.09 Insulated glass EE 140 IG/EE 013 0.38 0.38 0.12 0.11 0.11 0.1 Insulated glass Clear Wide grid bar IDL 013 0.43 0.43 0.23 0.22 0.19 0.19 Insulated glass LoE2 Wide grid bar IDL/LE 013 0.38 0.38 0.15 0.14 0.17 0.16 Insulated glass EE 140 Wide grid bar IDL/EE 013 0.38 0.38 0.11 0.11 0.09 0.09 Single glaze Clear Wide grid bar SG/WD 014 O.E9 0.74 0.294 0.32 0.262 0.305 Single glaze Clear Narrow grid bar SG/NR 014 0.7 0.75 0.338 0.371 0.311 0.363 Single glaze Clear Wide grid bar SG/WD 014 0.69 0.74 0.294 0.32 0.262 0.305 Single glaze Clear Narrow grid bar SG/NR 014 0.7 0.75 0.338 0.371 0.311 0.363 Single glaze Clear SG 014 0.7 0.76 0.385 0.425 0.364 0.426 Insulated glass Clear Wide grid bar IG/WD 014 V-3 0.44 0.266 0.281 0.237 0.27 Insulated glass Clear Narrow grid bar IG/NR 014 0.43 0.44 0.304 0.323 0.281 0.322 Insulated glass Clear IG 014 0.43P 0.44 0.35 0.37 0.33 0.38 Insulated glass LoE2 Wide grid bar IG/WD/LE 014 0.35 0.35 0.163 0.176 0.209 0.239 Insulated glass LoE2 Narrow grid bar IG/NR/LE 014 0.35 0.35 0.182 0.198 0.248 0.285 Insulated glass LoE2, IG/LE 014 0.354 0.35 0-2' 0.22 0.29 0.33 Insulated glass EE 140 Wide grid bar IG/WD/EE 014 0.36 0.35 0.117 0.123 0.116 0.127 Insulated glass EE 140 Narrow grid bar IG/NREE 014 0.36 0.35 0.128 0.136 0.137 0.152 Insulated glass EE 140 IG/EE 014 0.36 0.35 0.14 0.149 0.16 0.178 Insulated glass Clear Wide grid bar IDL 014 0.43 0.44 0.266 0.281 0.237 0.27 Insulated glass LoE2 Wide grid bar IDLJLE 014 0.37 0.36 0.163 0.176 0.209 0.239 Insulated glass EE 140 Wide grid bar IDL/EE 014 0.37 0.37 0.117 0.123 0.116 0.127 Single glaze Clear Wide grid bar SG/WD 018 0.94 0.97 0.49 0.52 0.48 0.53 Single glaze Clear Narrow grid bar SG/NR 018 0.94 0.97 0.54 0.56 0.54 0.58 Single glaze Clear SG 018 0.94 0.97 0.59 0.61 0.59 0.64 Insulated glass Gear Wide grid bar IG/WD 018 0.5 0.5 0.44 0.45 0.44 0.47 Insulated glass Clear Narrow grid bar IG/NR 018 0.5 0.5 0.48 0.49 0.48 0.52 Insulated glass Clear IG 018 0.5 0.5 0.53 0.53 0.53 0.56 Insulated glass LoE2 Wide grid bar IG/WD/LE 018 0.38 0.36 0.25 0.26 0.39 0.42 Insulated glass LoE2 Narrow grid bar IG/NR/LE 018 0.38 0.36 0.27 0.28 0.43 0.46 Insulated glass LoE2 IG/LE 018 0.38 0.36 0.3 0.31 0.47 0.5 Insulated glass EE 140 Wide grid bar IG/WD/EE 018 0.38 0.36 0.17 0.17 0.21 0.22 Insulated glass EE 140 Narrow grid bar IG/NR/EE 018 0.38 0.36 0.18 0.18 0.24 0.24 Insulated glass EE 140 IG/EE 018 0.38 0.36 0.19 0.2 0.26 0.27 Single glaze Clear Wide grid bar SG/WD 018 0.94 0.97 0.49 0.52 0.48 0.53 Single glaze Clear Narrow grid bar SG/NR 018 0.94 0.97 0.54 0.56 0.54 0.58 Single glaze Clear SG 018 0.94 0.97 0.59 0.61 0.59 0.64 Insulated glass Clear Wide grid bar IG/WD 018 0.5 0.5 0.44 0.45 0.44 0.47 Insulated glass Dear Narrow grid bar IG/NR 018 0.5 0.5 0.48 0.49 ' 0.48 0.52 Insulated glass Gear IG 018 0.5 0.5 0.53 0.53 0.53 0.56 Insulated glass LoE2 Wide grid bar IG/WD/LE 018 0.38 0.36 0.25 0.26 0.39 0.42 Insulated glass LoE2 Narrow grid bar IG/NR/LE 018 0.38 0.36 0.27 0.28 0.43 0.46 Insulated glass LoE2 IG/LE 018 0.38 0.36 0.3 0.31 0.47 0.5 Insulated glass EE 140 Wide grid bar IG/WD/EE 018 0.38 0.36 0.17 0.17 0.21 0.22 Insulated glass EE 140 Narrow grid bar IG/NR/EE 018 0.38 0.36 0.18 0.18 0.24 0.24 Insulated glass EE 140 IG/EE 018 0.38 0.36 0.19 0.2 0.26 0.27 Single glaze Clear Wide grid bar SG/WD 018 0.94 0.97 0.49 0.52 0.48 0.53 Single glaze Clear Narrow grid bar SG/NR 018 0.94 0.97 0.54 0.56 0.54 0.58 Single glaze Clear SG 018 0.94 0.97 0.59 0.61 0.59 0.64 Insulated glass Clear Wide grid bar IG/WD 018 0.5 0.5 0.44 0.45 0.44 0.47 Insulated glass Clear Narrow grid bar IG/NR 018 0.5 0.5 0.48 0.49 0.48 0.52 Insulated glass Clear IG 018 0.5 0.5 0.53 0.53 0.53 0.56 Insuiated glass LoE2 Wide grid bar IG/WD/LE 018 0.38 0.36 0.25 0.26 0.39 0.42 Insulated glass LoE2 Narrow grid bar IG/NR/LE 018 0.38 0.36 0.27 0.28 0.43 0.46 Insulatea glass LoE2 IG/LE 018 0.38 0.36 0.3 0.31 0.47 0.5 Insulated glass EE 140 Wide grid bar IG/WD/EE 018 0.38 0.36 0.17 0.17 0.21 0.22 Insulated glass EE 140 Narrow grid bar IG/NR/EE 018 C.38 0.36 0.18 0.18 0.24 0.24 [nsulateo glass EE 140 IG/EE 018 C.38 0.36 0.19 0.2 0.26 0.27 Single glaze Clear Wide grid bar SG/WD 018 0.94 0.97 0.49 0.52 0.48 0.53 Single glaze Clear Narrow grid bar SG/NR 018 0.94 0.97 0.54 0.56 0.54 0.58 Single glaze Clear SG 018 0.94 0.97 0.59 0.61 0.59 0.64 insulated glass fear '.Vide grid bar [G/WD 018 0.5 0.5 0.44 0.45 0.44 0.47 Page 6 of 10