Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1683 (SFD)
78-495 CALLE TAMPICO LA QUINTA, CALIF NI 9 3 Application Number: SFD-13-1683 Property Address: 53612 VIA DONA APN: 772420999 Application Description: NEW SFD Property Zoning: Application Valuation: $468,245.40 Applicant: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 4 Tw(t °F 4Qu&rw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT C 5 2c'.'5 C I? L,'- u i"LitiTA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 533670 y, Date: ��S'/`7 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add al� VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/5/2015 Owner: SEDONA HOMES INC 73091 COUNTRY CLUB NO A481 PALM DESERT, CA 0 Contractor: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 (760)773-6633 Llc. No.: 533670 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate cf consent to self -insure for workers' compensation, as provided for by Section 3700 c� the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of th:! work for which this permit is issued, I shall not employ any person in any manner so asAo become subject to the workers' compensation laws of California, and agree that, .f I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: I 7 r / p licant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,00%.. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOW:EDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and stat that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: I:b--- ) 6-- Signature (Applicant or Agent): FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $670.61 $0.00 PAID BY METHOD RECEIPT # - CHECK # CLTD BY Total Paid forART IN PUBLIC PLACES - AIPP: $670.61 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BLDG PC 200K -1M 10160003428200 $1,000.00 $1,000.00 1/3/14 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBLDG PC 200K -1M: $1,000.00 $1,000.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $19.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $19.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forDIF - SINGLE FAMILY DWELLING $6,894.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT = PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $73.98 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $30.48 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT = PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # = CHECK # CLTD BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $297.35 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $0.00 _ PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forGRADING: $143.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $181.30 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $120.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT _ PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $181.30 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $120.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $108.81 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $43.47 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $773.50 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $732.21 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forNEW CONSTRUCTION PERMIT: $732.21 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,577.08 $0.00 PAID BY' METHOD RECEIPT # CHECK # CLTD BY Total Paid forNEW CONSTRUCTION PLAN CHECK: $1,577.08 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $290.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $290.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ROOF DRAIN 101-0000-42401 0 $48.36 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ROOF DRAIN PC 101-0000-42600 0 $48.36 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY Total Paid for PLUMBING FEES: $822.09 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $60.87 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI $60.87 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forTUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:$1,000.00 • Permit Details PERMIT NUMBER City of La Qu i nta SFD=F13=1683_^i Description: NEW SFD Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: OK TO ISSUE Applied: 12/31/2013 STAFF NAME FAMILY DETACHED Approved: 4/14/2014 Parcel No: 772420999 Site Address: 53612 VIA DONA LA QUINTA,CA 92253 Subdivision: Block: Lot: Issued: Lot Scl Ft: Building Scl Ft: Zoning: Finaled: Valuation: $468,245.40 Occupancy Type: Construction Type: Expired: No. Buildings: No. Stories: No. Unites: Details: 4668 S.F. SFD, WITH 528 S.F. CASITA, GARAGE 1060 S.F. DECK 1278 S.F. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH. FIRE -PIT, WATER FEATURE OR BBQ. HOME IS FIRE SPRINKLED PER 2013 CRC CODES. 104, 0 J Applied to Approved Printed: Monday, January 05, 2015 12:22:55 PM 1 of 5 CRWsrSTEMs CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES TELEPHONE CALL JIM JOHNSON 12/9/2014 12/9/2014 CALLED LANCE TO INFORM HIM ABOUT FEES. NO ANSWER ON PHONE GOT MESSASE MACHINE CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SUNROSE CORPORATION 72850 SOMERA ROAD PALM Dfi6GRT CA 42260 CONTRACTOR SUN ROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT CA 92260 OWNER SEDONA HOMES INC 73091 COUNTRY CLUB NO A481 PALM DESERT CA 0 Printed: Monday, January 05, 2015 12:22:55 PM 1 of 5 CRWsrSTEMs Permit Details PERMIT NUMBER ..,r. City of La Quinta SFW,1'3` 1683 - Y DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY ART IN PUBLIC PLACES - 270-0000-43201 0 $670.61 $0.00 RESIDENTIAL Total Paid forART IN PUBLIC PLACES - AIPP: $670.61 $0.00 BLDG PC 200K -1M 10160003428200 $1,000.00 $1,000.00 1/3/14 Total Paid for BLDG PC 200K -1M: $1,000.00 $1,000.00 BSAS SB1473 FEE 101-0000-20306 0 $19.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION - $19.00 $0.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 DIF - COMMUNITY 254-0000-43200 0 $129.00 $0.00 CENTERS DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 DIF - PARK 256-0000-43200 0 $40.00 $0.00 MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 DIF - STREET 255-0000-43200 0 $116.00 $0.00 MAINTENANCE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 1 Total Paid forDIF - SINGLE FAMILY DWELLING $6,894.00 $0.00 RESIDENTIAL, EA 101-40or1.474n3 n $73.98 S0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $30.48 $0.00 ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF Printed: Monday, January 05, 2015 12:22:55 PM 2 of 5 CN?WSrsrEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,000SF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $297.35 $0.00 RESIDENTIAL FINISH 101-0000-426000 $143.00 $0.00 GRADING PC Total Paid forGRADING: $143.00 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $181.30 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $120.85 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 FURNACE 101-0000-42402 0 $181.30 $0.00 FURNACE PC 101-0000-42600 0 $120.85 $0.00 VENT FAN 101-0000-42402 0 $108.81 $0.00 VENT FAN PC 101-0000-42600 0 $43.47 $0.00 Total Paid for M ECHAN [CAL: $773.50 $0.00 NEW CONSTRUCTION 101-0000-424000 $732.21 $0.00 PERMIT Total Paid forNEW CONSTRUCTION PERMIT: $732.21 $0.00 NEW CONSTRUCTION 101-0000-4261 Q I $1,577 n8 tn,nn PLAN CHECK Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,577.08 $0.00 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 Printed: Monday, January 05, 2015 12:22:55 PM 3 of 5 CRWYSTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 FIXTURE/TRAP 101-0000-42401 0 $290.16 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $290.16 $0.00 GAS SYSTEM, 5+ 101-0000-42401 0 $36.26 $0.00 OUTLETS GAS SYSTEM, S+ 101-0000-42600 0 $24.17 $0.00 OUTLETS PC ROOF DRAIN 101-0000-42401 0 $48.36 $0.00 ROOF DRAIN PC 101-0000-42600 0 j $48.36 $0.00 WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 WATER HEATER/VENT 101-0000-42600 0 $7.25 $0.00 PC WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $12.09 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $822.09 $0.00 SMI - RESIDENTIAL 101-0000-20308 1 0 $60.87 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $60.87 $0.00 SINGLE FAMILY 224-0000-203200 $1,837.44 $0.00 DETACHED Total Paid forTUMF - RESIDEN PIAL: $1,837.44 $u.uu TOTALS:$1,000.00 Printed: Monday, January 05, 2015 12:22:55 PM 4 of 5 CRWYSTEM5 REVIEW TYPE I REVIEWER I SENT DATE I DUE DATE I RETDUAR EED I STATUS I REMARKS I NOTES Printed: Monday, January 05, 2015 12:22:55 PM 5 of 5 Cl?wsrsTEMS P.O. BOX 1504 Building,r f 78-495 CALLE TAMPICO Address.? 3 - &II 6 � , Do it LA QUINTA, CALIFORNIA 92253 _)ICA01fa ��e1& '1_;7k L. Mailing 41 Address �Q -�Q 0 Oc- b 1 -,2-11/ � CiW Zip Y 2� - D Tel. 160 -773 - 6o3 contractor Address t0 -101 1- vY C�t�i�OGlt�%u zi6 �Z�� Tel. Z6d �Z73 �63� State Lic.c�, & Classif.✓� '7D City Lic. # Arch., Engr., Designer kC Address Tel. iib Sr ©G>��v ZW k%I}'/� / f __�-,,, L .. Zip a --%`P : r State LIC. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the Provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is.exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) A Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE .(This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). *1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject !o the Workers' Compensation provisions of the Labor Code, you must forthwith comply wim such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT tt13 ��83 APPL.CATION ONLY BUILDING: TYPE CONST. r Lgt> OPP. CC. GRP A.P. Number -71/7- 1�`� -e to Legal Description Project Description Sq. Ft. t No. No. DIN. Size) 6 Stories 7, Units NewX Add ❑ Alter ❑ Repair ❑ Demolition ❑ EATy0F LA QUINTA Estimated Valuation t—r PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback frcrn Center Line Rear Setback fro n Rear Prop. Line _ Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE Issued by: INSPECTOR Date Permit IValidated by: Validation: YELLOW = APPLICANT PINK = FINANCE 13,V7-15 t Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: 10TIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:[I he Hideaway Date: January 5, 2015 Owner's Name: Sedona Homes, Inc. Phone Xo. 760-773-6633 Project Address: 53-612 Via Dona, LaQuinta Project Description: New SFD APN: 777-420-010-4 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 5196 Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: January 5, 2015 Signature: *****************************************-*************4**************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 5196 $3.36 $17458.56 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from 3eveloper fees. Any mobile homes being relocated within tte same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this D -strict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day ?eriod to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other Epplicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable'at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts en the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocsldevfeesicelliiicate of compliance form updated 3-2007 11/2010 RECORDING REQUESTED BY: COMMONWEALTH LAND TITLE COMPANY AND WHEN RECORDED, MAIL TO: Sedona Homes Inc. 73091 Country Club Drive Ste. A 481 Palm Desert, CA 92260 DOC # 2008-0667953 12/23/2008 08:00A Fee:12.00 Page 1 of 2 Doe T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder 1111111111111111111111111111111111111111111111111111111 S R I U PAGE SIZE DA MISC I LONG RFD COPY M A L 465 426 PCO NCOR SMF NCHG exnM T TY UNI GRANT DEED T 006 ASSESSOR'S PARCEL NO.: 777-420-010 yThe undersigned Grantor(s) declare that the DOCUMENT TRANSFER TAX IS: TITLE ORDER NO.: 2154486 $ 385.00 County ESCROW NO.: 25875-003 XX computed on the full value of the interest of property conveyed, or computed on the full value less the value of liens or encumbrances remaining thereon TYt.-CN.'O-L'�>-at the time of sale. OR transfer is EXEMPT from tax for the following reason: FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Old World Wood, Inc., A California Corporation hereby GRANT(S) to Sedona Homes Inc., A California Corporation all that real property situated in the City of La Quinta, County of Riverside, State of CA, described as: Lot 27 of Tract No. 29894-4, as shown by Map on file in Book 351, Pages 49 to 57, inclusive, of Maps, in the Office of the County Recorder of Riverside County, California. Dated December 17, 2008 State of Califbmi2} County -d } On Before eL Ti / (i�� Notary Public Personally appeared _7L6hP.t✓l�/J p. Who proved to me on the basis of satisfactory evidence to be the personK whose name 1s/are, subscribed to the within instrument and acknowledged to me tha a/shefthay executed the same in".s authorized capacity(iass), and that by is%herltheir signature(pa on the instrument the person(o or the entity upon behalf of which the personoo acted, executed the instrument. I certify under PENALTY OF PERJURY under. the laws of the State of California that the foregoing paragraph is true and correct. WITNE/$3 my h d -and o _ • ial seal Signature 7 MAIL TAX STATEMENTS' TO: Sedona Homes Inc. 73091 Country Club Drive Ste. A 481 Palm Desert, CA 92260 Old World By: Commisc!on at<• 7 57 7,130 H i401ury Pub:lc' - Cailiorrda I�iverst in County ��>'°`� il4yt�omrn. Exp!ros!V!ay 17, 2009 ,IFCE1VED MAR 2 4 2014 CIT► DF to QU114 rA &qMt4UNVy DEVELIPPMENT (This area for official notary seal) HIDEAWAY OWNERS ASSOCIATION April 13, 2009 Sedona Homes Attn Mike Tuvell and Lance Alacano 73091 Country Club Drive, Suite A4-81 Palm Desert, CA 92260 RE: Sedona Homes/Final Design Review Lot 27D at 53612 Via Dona Dear Mr. Tuvell and Mr. Alacano, The Hideaway Design Review Committee met to review your submittal of Final Design plans for your Lot 27D at The Hideaway. The plans were approved for construction to -:)egin provided the following comments are addressed prior to the setback inspection: 1. The pool and spa equipment is still located directly outside the bedrocm windows. This will need to be moved. 2. The approved colors need to be shown on the architectural plans. 3. Stone caps should be used on the planter walls located in the front yard 4. The landscape architect mentions that the screen walls will be raised =0 6', the plans do not reflect this but the grading plan does. 5. Please be sure that adequate room is given for the palms shown in the equipment area. Any deviation from the Design Guidelines must be submitted with a request for Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process it will be the design team's responsibility to make modifications at a later date if requested by the Design Review Committee. Please call Mindy Gutierrez at (760) 3 93 -5211 to schedule your preconstruction meeting. Sincerely, Hideaway Design Review Committee cc: Anton Marinkovich, John Krieg, Gerry Tarsitano, DRC File 80955 Avenue 52 La Quinta, CA 92253 P: 760 393-5210 F: 760 398-5788 I CITY'OF-LA QUINTA - PUBLIC'WORKS'DEPARTMENT'GREEN'SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed .- below, are complete. Incompleteapplicationsor:applications which cannot. be - processed -will _be_returned,to applicant-- _ Date: 02 / 28 / 14 Developer: Sunrose Corporation ` Tract No: 29894 -4 --=Tract Name:=tiideaway C C"�-- «-CotNo:(s):27D-=� -� - --�--r---- --_- !Z Address(s):=Via Dona Phone Number:7( 60 ) 773-6633 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the r� Building & Safety Department: CUSTOM'HOMESPROVIDE ITEMS #2,J# , #4: ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1. #2, #3, #5 & #7 BELOW �_- _•:., WALLS, SIGNSrOTHER:s:PROVIDE ITEM #6 BELOW x R - 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation.of.+/T 0.1 foot), .Pad Elevation Certificates, must be,current (within -6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal untillaa Pad Elevation _ T Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils - Engineer.- =Engineer._Recently-rough,7graded- residential -developments: which have !a�previousty= approved geotechnical--= certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. w4_^_Complete the. attached <1 acre per.lot or_infiIIrproject Fugitive; Dust Control project information form,,PM10 plan & , agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM 10 certification number is required. "-� T-5`-�Attach a -co- .. of`the,rou.h-oF recise radifi4- lar -to the -Public W6-rks-D6 50rnent7showin 'buildin 'locations'' PY 9 P 9 9 P P 9' 9' () for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7._ Complete- and. sign;,the; attached,water-. quality- management, plan(WQIVIP), exemption Jorm, -if-. applicable->_P_W, - approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved Tap/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx 1 have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, -'the above project maybe released for, building: permit issuance. 2:- This section completed by City staff. Recommended by: Date: Public Works Distribution: ( ) Green Sheet to Building & Safety )Green Sheef fo Planning Depaitmenf-- Declined for approval for reason(s) as follow(s), please correct and resubmit: '� : T:lChecktists - Fonns & Applicationsworms & Apptications\GREEN SHEET cover& PM10less than t Acre Revised 9-25-09.doc - - --='•=--��' —'<- ^_-.Y -"-- =^ = ,-"�.. City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement <1 acre/lot or Infill Project Project Information Project Contractor: Sunrose Corporation Project Phase (check one) Construction Demolition Project Name: Sedona Homes Project Tract/Lot Numbers: 29894-4 / Lot 27D Project Street Address: 53613 Via Dona Total Acres in Active Construction (<1 acre per Lot): 15,637 02 28 14 02 28 14 Anticipated Start Date: / / Anticipated Completion Date: / / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: Jenny McIntire Title: Administration Company Name: Sunrose Corporation Mailing Address: 40101 Monterey Ave. #B1-214 City, State, ZIP Code: Rancho Mirage, CA 92270 Primary Phone #: 760-773-6633 Fax #: 760-773-0634 24 Hour Emergency Phone#: 760-773-6633 Cell Phone #: 760-702-0119 Email Address: sedonahomes@dc.rr.com PM 10 Certificate #: I CV1402-000405-449 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceab lity, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) dais a week, throughout the period of project performance, regardless of project size or status; s Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/o- abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions- related to this dust control plan or any City/C un initiated abatement activities. )111� Q�-� 511")111 of Prop Owner or Authorized Representative Date TAC-hecklists - Forms & ApplicationsWonns & ApplicationslGREEN SHEET cover & PM10less than 1 Acre Revised 9-25-09.doc EsGil Corporation In Tartnership witk Government for Building Safety DATE: 04/08/14 JURISDICTION: La Quinta PLAN CHECK NO.: 13-1683 PROJECT ADDRESS: 53-612 Via Dona SET: II ❑ APPLICANT ❑ JURIS. ❑ PLAN REVIEWER ❑ FILE PROJECT NAME: SFD/ Garage/ Casita/ Covered Porches/Decks for Sedona Homes ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by bLilding department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are. being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. . ❑ The applicant's copy of the check list has been sent to: ® EsGil Corporation staff did not advise the applicant that the plan check has been completed. ❑ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person Fax #: ® REMARKS: Permit is for Building Structure Only. Pool , spa , site walls and other landscape features are not apart of this permit. Structural observation required per sheet SGN. By: Ray Fuller EsGil Corporation F1 GA C-] EJ ❑MB ❑ Enclosures: PC (E/PME/RL) 04/01/14 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Ii Plan Submittal Building Permit Number. Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan 1/31/2014 Job Sfte Address l 53611 Vla Dona Owners Name Number, Street, or PO Bo* City, State, Postel Code Owner's Phone Number Owners E -Mall Address Project Managers Name Project Managers Phone Number Project Managers E-mail Address Builder / Contractor', Number, Street or PO Box City, State, Postal Code Protect Square Footage City Approval By Sedona Homes, Inc. 40101 Monterey Ave., B1-214 Rancho Mirage, CA 92270 Jenny 773.6633 Sunrose Corp. 40101 Monterey Ave., B1-214 Rancho Mirage, CA 92270 RECEIVED MAR 2 4 2014 CM OF LA QUIIffA COMMUNrfy DEVELOPMENT Date of City Approval fx Materials To Be Discarded: Product Tons Trash 9.87 Not recyclable Product Asphalt 0.00 Recyclable Masonry (broken) Brick/Block 0.00 Recyclable Plaster Cardboard 1.71 Recyclable Scrap Metal Commingled 0.00 Recyclable Tile (floor) Concrete 0.42 Recyclable Tile (roof) Drywall 0.31 Recyclable Wood Donated / Reuse* 0.00 Recyclable Landscape Debris f 'Describe Items I Totals: Recycle Trash Projected Diversion: 17.3 9.9 63.7% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. l hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shell guarantee that at least 5D% of the jobsite waste la diverted from landfilling. The remaining materiel will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DHAP is issued in the name of the property owne(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP Is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept Informed of the diversion progress through bHnonthlh reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer station. Owner/ Developer'rProject Manager / Suparintendant Date 9 I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Sedona Homes Hideaway Lot #27D La Quinta, CA 92253 Project Designer: STRACTS, Inc. 550 S. Oleander Palm Springs, CA 92264 (760) 636-8951 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: 3/12/2014 b; t cif OF LA QUIINTA COMr4LNM DEVELOPMENT CITE' OF LA QUINTA BUILUN , 84. 'A'FETY !SEPT. FOR CONST f i�CTION DATE B The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. Tris program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-03-12716:49:31 /D: t"p W • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additior/Alteration Date 3/12/2014 Project Address Hideaway Lot #27D La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,196 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,470 Radiant Barrier New Wall Wood Framed R-21 4,733 New Slab Unheated Slab -on -Grade None 4,384 Perim = 419' New Door Opaque Door None 22 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (N) 137.0 0.390 0.39 none none Bug Screen New Rear (E) 210.0 0.390 0.39 none none Bug Screen New Front (W 213.0 0.390 0.39 none none Bug Screen New Left (N) 40.0 0.390 0.39 14.0 none Bug Screen New Rear (E) 185.0 0.390 0.39 18.0 none Bug Screen New Right (S) 193.0 0.390 0.39 none none Bug Screen New Front (IM 40.0 0.940 0.43 none none Bug Screen New Rear (E) 46.0 0.390 0.39 11.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented t:.0 New HVAC 2 & 3 Ducted Ducted Attic, kCeiling "Ins; wente— dy New HVAC 4 Ducted Ducted Attic, Ceiling Ins; -vented,' , t_t-y Q (E!O !+ l 1 A New WATER HEATING - " ``" "� :�tii-` j. Y- DEPT, Qty. Type Gallons Min. Eff Distribut oni-to F- Status 1 Large Gas 100 �RUC 0.80 � All Pipes•InW sl.vIVJ j UCT'Q(V New E3y--- EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12T16:49:31 ID: Page 3 of 37 10 C PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family 0 Addition Alone O Multi Family 0 Existing+ Addition/Alteration Date 3/12/2014 Project Address Hideaway Lot #27D La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,196 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type ' Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins . Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff The,mostat Status 1 Central Furnace 80% AFUE Splii Air Conditioner 15.5 SEER Setbacb New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins; vented_-- 3:0�. New 5' LA n ih..6:A EAFETyT WATER HEATING, Qty. Type Gallons Min. Eff Distributionf)R CONS- i �� Stat js • 'Y r ATE RV EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-03-12716:49:31 ID.� Page 4 of 37 EO C C PERFORMANCE CERTIFICATE: Residential Part 22 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 3/12/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White M-I-100S6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 690.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 313.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 306.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 75.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 234.0 ft2 Covered Slab Floor, 3.500" thick at Great/Dining/Kitchen/Nook HIGH MASS Design - Verify Thermal Mass: 2,238.0 ft2 Exposed Slab Floor, 3.500" thick at Great/Dining/Kitchen/Nook The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 10 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 282.0 ft2 Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 246.0 ft2 Exposed Slab Floor, 3.500" thick at Casita HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA548 / 58CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing :s required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA548 /58CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA536 / 58CVX070 includes credit for a 12.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 24APA524 / 58CVX070 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field veriflca�fidn'and- diagnostic testing s required to verify that duct leakage meets the specified criteria. 7 Y ",FETY nl=D-r • ..�iv� I I-S�.K; ��jOi'V BY —�__ EnerqvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12716:49:31 ID: Page 5 of 37 C 0 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additicn/Alteration Date 1311212014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items -equire special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Lased on the adequacy of the special 'ustification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation crite*a as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. FF --r,, O .fes, o--- %—ve r r Vii` IJA Q,UBNTA '-UH CONSTRUCTION DATE EnergyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 201403-12T16:49:31 /D: Page 6 of 37 C=7 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes 1 ❑ Multi Family • ❑ Existing+ Addition/Alteration 3/12/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.95 4.52 0.43 Space Cooling 54.07 49.68 4.39 Fans 10.92 14.44 -3.52 Domestic Hot Water 6.61 4.35 2.26 Pumps 0.00 0.00 0.00 Totals 76.55 72.98 3.57 Percent Better Than Standard: 4.7 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (tM 290 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tM °,272 253 Fuel Available at Site: Natural Gas (N) 1,529 177 Raised Floor Area: 0 (E) 1,447 441 Slab on Grade Area: 4,384 (S) ',571 193 Average Ceiling Height: 11.3 Roof 4,470 0 Fenestration Average U -Factor: 0.41 TGTAL: 1,064 Average SHGC: 0.39 Fenestration/CFA Ratio: 20.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 3/12/1014 City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizesathat,compiiance-using-duct esign, duct sealing, verification of refrigerant charge, insulation installation quality,rand�bulldtng1en�elope '1-q,� Ire installer testing and certification and field verification by an approved HERS tater-. )IIv3S SAFETY Y DEPT, Designer or Owner (per Business & Professions Code) A3 (�i� ® F! Company STRACTS, Inc. FOR CONSTRJCTION [DATE Address 550 S. Oleander Name Anton Marinkovich City/State/Zip Palm Springs, CA 92264 Phone (760) 636-8951 –Signed— BY License # Date EneroyPro 5.1 by Ene Sok User Number: 6712 Run Code: 2014-03-12T16:49:31 /D: Pae 7 of 37 C CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1-1/1212014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Append:x Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 926 0.025 R-38 0 0 New 4.2.1-A21 Master Bedroom Wall 465 0.069 R-21 20 90 New 4.3.1-A6 Master Bedroom Wall 194 0.069 R-21 110 90 New 4.3.1-A6 Master Bedroom Wall 140 0.069 R-21 200 90 New 4.3.1-A6 Master Bedroom Wall 60 0.069 R-21 290 90 New 4.3.1-A6 Master Bedroom Slab 690 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 313 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Wall 225 0.069 R-21 20 90 New 4.3.1-A6 Bedroom 2 Wall 113 0.069 R-21 290 90 New 4.3.1-A6 Bedroom 2 Slab 306 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 751 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 2,204 0.025 R-38 0 0 New 4.2.1-A21 GreatlDinin /Kitchen/Noo Wall 138 0.069 R-21 20 90 New 4.3.1-A6 Great/Dinin /Kitchen/Noo Wall 363 0.069 R-21 110 90 New 4.3.1-A6 Great/Dinin /Kitchen/Noo Wall 731 0.069 R-21 200 90 New 4.3.1-A6 Great/Dinin /Kitchen/Noo Wall 366 0.069 R-21 1 290 90 New 14.3.1-A6 Great/Dinin /Kitchen/Noo FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 20.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window Master Bedroom 2 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windowl Master Bedroom 3 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window'Master Bedroom 4 Window 24.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window, -Master Bedroom 5 Window 48.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window,- Master Bedroom 6 Window 24.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window; Master Bedroom 7 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window, -Bedroom 2 8 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window -Bedroom 2 9 Window 6.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions VVindow'Bedroom 2 10 Window 6.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window. Bedroom 2 11 Window 40.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window Great/Dining/Kitchen/Nook 12 Window 185.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window Great/Dining/Kitchen/Nook 13 Window 40.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window Great/Dining/Kitchen/Nook 14 Window 40.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window Great/Dining/Kitchen/Nook 15 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window Great/Dining/Kitchen/Nook 16 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window Great/Dining/Kitchen/Nook (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len Hct Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Sua Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 8.0 5.0 14.0 0.1 14.0 l 14V"' B U ) ,A 12 Bug Screen 0.76 10.0 18.5 18.0 0.1 18.0 1 1i8!,0 I I !) J, v, r `` ! 1I A g 13 Bug Screen 0.76 14 Bug Screen 0.76 -ILA �-J 9 ,n 15 Bug Screen 0.76 T I JBug Screen 0.76 ' ' hi DATE RV I EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-03-12T16:49:31 a e 8 of 37 C c CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addit'on/Alteration Date 3/12/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Append x Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Door 22 1.450 None 290 90 New 4.5.1-A1 Great/Dinin /Kitchen/Noo Slab 234 0.730 None 0 180 New 4.4.7-A1 Great/Dinin /Kitchen/Noo Slab 2,238 0.730 None 0 180 New 4.4.7-A1 Great/Dinin /Kitchen/Noo Roof 812 0.025 R-38 1 0 0 New 4.2.1-A21 2nd Floor Wall 2561 0.069 R-21 20 90 New 4.3.1-A6 2nd Floor Wall 2851 0.069 R-21 110 90 New 4.3.1-A6 2nd Floor Wall 209 0.069 R-21 200 90 New 4.3.1-A6 2nd Floor Wall 263 0.069 R-21 290 90 New 4.3.1-A6 2nd Floor Roof 528 0.025 R-38 0 0 New 4.2.1-A21 Casita Wall 268 0.069 R-21 20 90 New 4.3.1-A6 Casita Wall 164 0.069 R-21 110 90 New 4.3.1-A6 Casita Wall 298 0.069 R-21 200 90 New 4.3.1-A6 Casita Wall 195 0.069 R-21 290 90 New 4.3.1-A6 Casita Slab 282 0.730 None 0 180 New 4.4.7-A1 Casita Slab 246 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 18 Window 12.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 19 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 20 Window 12.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 21 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Windows Great/Dining/Kitchen/Nook 22 Window 12.5 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 23 Window 12.5 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 24 Window 16.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window: GreaUDining/Kitchen/Nook 25 Window 4.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 26 Window 40.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window; Great/Dining/Kitchen/Nook 27 Window 16.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Windowi Great/Dining/Kitchen/Nook 28 Window 4.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window: Great/Dining/Kitchen/Nook 29 Window 40.0 0.940 NFRC 0.43 NFRC 290 New Laminated Entry Door Great/Dining/Kitchen/Nook 30 Window 10.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions WindowGreat/Dining/Kitchen/Nook 31 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window: 2nd Floor 32 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window; 2nd Floor (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt REA Dist Len Hct Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 , 24 Bug Screen 0.76"��-- 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 ` tx ; 28 Bug Screen 0.76 29 Bug Screen 0.76 j 30 Bug Screen 0.76 31 Bug Screen 1 0.76 ON 32 JBug Screen 1 0.76 fl f E By EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-12T16:49:31 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1311212014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 40.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 34 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 35 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 36 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 37 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window. 2nd Floor 38 Window 6.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: 2nd Floor 39 Window 6.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window. 2nd Floor 40 Window 10.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window., 2nd Floor 41 Window 40.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Windows 2nd Floor 42 Window 10.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Windows 2nd Floor 43 Window 6.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Windowl 2nd Floor 44 Window 20.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window 2nd Floor 45 Window 40.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Windo 2nd Floor 46 Window 20.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Windowl 2nd Floor 47 Window 24.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Wndowj Casita 48 Window 6.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window. Casita (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left FinRi ht Fin Len H t LExt RExt Dist Len Hot Dist Len H t 33 Bug Screen 0.76 8.0 5.0 11.0 0.1 11.0 11.0 34 Bug Screen 0.76 3.0 2.0 11.0 0.1 11.0 11.0 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 j , ` ' -" + k -i 117 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 I , "�', 1 44 Bug Screen 0.76 hot I wIVz ► H45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 - BY� _ 48 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-03-12T16:49:31 ID: Pae 10 of 37 C NAL U CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additon/Alteration Date 1-111212014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Append x Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 6.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windows Casita 50 Window 6.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window: Casita 51 Window 10.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Wndow.- Casita 52 Window 40.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window: Casita 53 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window= Casita 54 Window 6.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Casita 55 Window 6.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window: Casita 56 Window 25.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window: Casita (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 ----_ . N C; Y' �M'= 1 � � ...=� fully 1A N Y Y._L.JI V 0 z.4\ - g iiU N L — ---_ BY I EnergyPro 5.1 by Energ ySoft User Number: 6712 RunCode: 2014-03-12T16:49:31 ID: Pae 11 of 37 C x CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Sedona Homes Building Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addit on/Alteration Date 1 3/12/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,003 10,231 Bedroom 2 381 3,810 HVAC 2 & 3 Great/Dining/Kitchen/Nook 2,472 32,630 HVAC 4 2nd Floor 812 6,902 HVAC 5 Casita 528 5,280 Totals 5,196 0 0 0 HVAC SYSTEMS System Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Slit Air Conditioner 15.0 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE S lit Air Conditioner 15.5 SEER Setbacc New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 1 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distr;bution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loas or Filot Ext. Tank Insul. R- Value Status Bradford White M-1-10056 1 Large Gas All Pipes Ins 90,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft \ o Q�'—+ — C; p -)t--- Bull D u; S stem,,Nam_er..- Pipe:� LFn th ,�11\1TA �, rPpe Diar�'et r 71nsul.Control hick. Qt . HP Plenum Outside Buried ❑ ❑ I , ❑ N DATE By_ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12T16:49:31 ID: Pae 12 of 37 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R r-, Project Name Date �_14Sedona Homes 1311212014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Sum-nary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50a : Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50d : Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.30; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioratio 1. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 1 50e 1 A: Masonry or factory-built fire laces have a closable metal or glass door covering the entire open nq of the firebox. §150(e)l B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are ,ertified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupEncies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113 c'5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112 c). _ §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the _ tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated-between.he`at, in_g source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. , V r!,_ ,. Pipe insulation for steam hydropic heating systems or hot water syst s �5�psi,;m�� s t��he'r qr eT en Konisrds Table §23-A.1 23 A)2. 150(4)3A: Insulation is protected from damage, including that due to sunlight, moistures a ui�me6ffnaintenance an wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vaporl.retaarddan�t Jrr�e� sEd�bntirely i " conditioned space. 150(j)4: Solar water-heating systems and/or collectors are certified by the Solar, Rating and Certification Cbr oration. _ Hit---BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12T16:49:31 /D: Page 13 of 37 G C C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Sedona Homes 1311212014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a mnimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with mwerials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and prcvides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with ft Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units urger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmabre,control,system; and all permanently installed . -_ _ --�._ luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility d"_ooms are high effi---cacy and'controlled=by manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no rriord-than.20,watts Of power qer linear_foot of illuminated cabinet. __� -, — Ljt:PT. VLD FUR C 01\1S'1-R?JCT10N DATE EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2014-03-12716:49:31 ""lD= ——Pge 14 of 37 Le C MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date 43edona Homes 1311212014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are contro led by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requiremerts of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detF-ched storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact ( C) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building :)r to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that:disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). }§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. C SIT' 0- LA C_')UITA IFUILDIN,O et S RETY DEPT. �' lED F013COtNSTRUCTION DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12716:49:31 /D: age 15 of 37 C C 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I Project Name ,Sedona Homes Date 3/12/2014 System Name HVAC 1 Floor Area 1,384 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 716 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 13,879 1,560 294 16,586 Total Output Btuh 89,000 0 Output Btuh/s ft 64.3 654 633 Cooling System 0 0 Output perSystem 46,000 0 0 0 0 Total Output Btuh 46,000 2,480 1,560 -2,480 Total Output Tons 3.8 654 633 Total Output Btuh/s ft 33.2 Total Output s ft/Ton 361.0 1 17,667 15,372 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24APA548 / 58CVX090 34,819 5,622 89,000 Airflow cfm/s ft 1.16 89,000 F Jan 1 AM Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 34,819 5,622 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Avg 3 PM Outside Air cfm/s ft 0.00 )Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 0 cfm 70 OF -d 70 OF 122 OF 123 OF Heating Coil Supply Fan o 1,600 cfm 123 F ROOM 70 OF A COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78/64°F 78/64°F 58/57°F 59/57°F �-----l—rre _ aJ, �lr y 1 `�-KLANT =11. , _9 _ ��ILC}�;�1L# ��1 c. Supply Fan .�rii 60 / 57 °F Cooling Coil 1' SEPT`, 1,600 cfmia L = ` # F , , V F2OOM FOR COt�ii;U /n 7f/64°F DATE= EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12716:49:31 /D: Page 16 of 37 C HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ,,Sedona Homes Date 3/12/2014 System Name HVAC 2 & 3 Floor Area 2,472 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 1,467 28,763 Return Vented Lighting 0 Return Air Ducts 1,355 Return Fan 01 Ventilation 0 0 Supply Fan 4,960 Supply Air Ducts 1,355 TOTAL SYSTEM LOAD 1 36,434 PEA{ COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 89,000 2,072 573 32,321 Total Output Btuh 178,000 Output Btuh/s ft 72.0 1,234 Cooling System 0 Output per System 46,000 0 0 0 Total Output Btuh 92,000 2,072 -4,960 Total Output Tons 7.7 1,234 Total Output Btuh/s ft 37.2 Total Output s ft/Ton 322.4 29,828 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Alrflow cfm 3,200 Carrier 24APA548 / 58CVX090 70,408 10,172 178,000 Airflow cfm/s ft 1.29 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 70,408 10,172 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Arg 3 PM 178,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 122 OF 123 OF Heating Coil Supply Fan ° 3,200 cfm 123 F ROOM I 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78 / 64 OF 78/64°F 58/57°F 59/57°F C 0 r� , c '-- y Cooling Coil Supply Fan Li(f jl_�j��. ��l � Q I NT,q 6 /5 °F 3,200 cfm u 1 -m FOR C(D,%S- , PA. CTfOiy 8 / 64 OF DqrE By EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12T16:49:31 /D: Page 17 of 37 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name �Sedona Homes Date 3/12/2014 System Name HVAC 4 Floor Area 812 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 658 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEA{ COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 13,437 1,081 182 10,891 Total Output Btuh 71,000 0 Output Btuh/s ft 87.4 633 416 Cooling System 0 0 Output per System 35,200 0 0 0 0 Total Output Btuh 35,200 1,675 1,081 -1,675 Total Output Tons 2.9 633416 Total Output Btuh/s ft 43.3 Total Output s ft/Ton 276.8 16,378 10,048 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA536 / 58CVX070 27,444 3,241 71,000 Airflow cfm/s ft 1.48 Total Adjusted System Output 27,444 3,241 71,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Ag 3 PM Jan 1 AM Airflow cfm/Ton 409.1 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 0 cfm 70 OF 70 OF 125 OF ^ 127 OF 10 Heating Coil Supply Fan 126 OF 1,200 cfm ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78/64°F 78/64°F 57/56°F 58/56°F c erg g �p g Supply Fan U'i ` �� �!' 1 'NTA �A 59 / 57 OF Cooling Coil 1,200 cfm �I .G R SAFE -P( REPT. r, ;-%x"5,45:'6%" 00 FOR CONSTRUCTION RUCTION 78 / 64 OF DATE B�, EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12716:49:31 /D: Page 18 of 37 E10 L L HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sedona Homes Date 3/12/2014 System Name HVAC 5 Floor Area 528 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 468 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 8,981 643 121 10,727 Total Output Btuh 71,000 0 Output Btuh/s ft 134.5 423 409 Cooling System 0 0 Output per System 22,800 0 0 0 0 Total Output Btuh 22,800 995 643 _995 Total Output Tons 1.9 423 409 Total Output Btuh/s ft 43.2 Total Output s ft/Ton 277.9 1 10,822 10,552 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 24APA524 / 58CVX070 17,188 2,916 71,000 Airflow cfm/s ft 1.52 Airflow cfm/Ton 421.1 Outside Air °i° 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 17,188 2,916 Aug 3PM 71,000 Outside Air cfm/s ft 0.00 )Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 153 OF 154 OF ren Heating Coil Supply Fan 154 OF 800 cfm ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78/64°F 78/65°F 58/57°F 59/58°F c Cooling Coil Supply Fan 800 cfmKr% _ I LA 0, MI �� � BUILDINC3 & SA(=ET Y 0,69_/1'58 °F Ai FO cotjS- RI ! TInKI 78/64° UAIE BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12716:49:31 /D: Page 19o ROOM LOAD SUMMARY Project Name Date Sedona Homes 3/12/2014 System Name Floor Area HVAC 1 1,384 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM Sensible Master Bedroom Master Bedroom 1 564 10,942 1,041 564 10,942 1,041 223 12,573 Bedroom 2 Bedroom 2 1 1 151 2,938 1,519 151 2,938 519 71 4,013 * Total load for zonal PAGE TOTAL G 1 DATE Z uf 716' JIV TOTA T879,( j(` ' 560 294116,586 716 13,879 1,560 29" 16,586 PAGE TOTAL G 1 DATE Z uf 716' JIV TOTA ROOM LOAD SUMMARY �72 Project Name Sedona Homes 32,321 Date 3/12/2014 System Name HVAC 2 & 3 p73 Floor Area 2,472 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Great/Dining/Kitchen/Nook Great/Dining/Kitchen/Noo 1 1,467 28,763 2,072 1,467 28,763 2,072 573 32,321 ' Total includes ventilation load for zonal systems. PAGE TOTAL" TOTAL ' r — I Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 201403-12Wd 49131 /D: Page 21 of �37 � 1;4i67 �72 X73 32,321 �1�46-7 V� 2817.6�.�Tj�;,O� p73 32,321 ROOM LOAD SUMMARY Project Name QSedona Homes System Name HVAC 4 ROOM LOAD SUMMARY 3/12/2014 Area 812 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name J Mult. I CFMSensible Latent CFM I Sensible I Latent CFM I Sensible 2nd Floor 2nd Floor 1 1 1 658 13,4371 1,081 6581 13,4371 1,081 1821 10,891 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal rl r -- /658g^13437 11081�IN 182 1 10,891 r�G58 CiCi1a437 v X108: 18211 10,891 101 ROOM LOAD SUMMARY Project Name Date Sedona Homes 3/12/2014 System Name Floor Area HVAC 5 528 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible (Latent I CFM I Sensible Casita Casita 1 1 468 8,981 643 468 8,9811 6431 1211 10,727 * Total includes ventilation load for zonal EnemvPro 5.1 by EnemySoft User N PAGE TOTAL TOTAL* '01403-12TI &: D[NG cr-": SJI ET%J DE t e --), i--1 r -, "-k t I -:-e r-, InN 1121 10,q727 468 81981 ., 643 121 10, C Es ROOM HEATING PEAK LOADS Project Name7311212014 Sedona Homes ate ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1, 003.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X w.,'"/,6 i AT *F = = = = = = Btu/hr R-38 Roof Attic 926.0 0.0250 44 1,019 R-21 Wall 859.0 0.0690 44 2,608 Architectural Traditions Windows 141.0 0.3900 44 2,420 Slab -On -Grade perim = 100.0 0.7300 44 3,212 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface 1,003 X X Area another room --------..a.,_--.____ CITY 10.20 t�0415' X \ Height ACH, FOR Page Total OF ; > X al�r�-rtii4�c_ �" �' ED G ,J l 9,258 A 3,315 TOTAL HOURLY HEAT LOSS FOR ROOM' �2 573 DATE 3Y Ene Pro 5.1 b Energ Soft User Number: 6712 Run Code: 2014 03-12T16:49:3 age 4 of 37 L401 A ROOM HEATING PEAK LOADS Project Name Sedona Homes 73/12/2014 Date ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Floor Area 381.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ° i P AT °F = = = _ = = was 44 Ut=P D Btu/hr R-21 Wall 338.0 0.0690 44 1,026 Architectural Traditions Windows 37.0 0.3900 44 635 Slab -On -Grade perim = 34.0 0.7300 44 1,092 Items shown with an asterisk (`) denote conduction Infiltration: 1.00 1.064 X Schedule Air Sensible Fraction through an interior surface X 381 X Area another roorsi.......EY__ A 10.00 Xy 0.42„4 Height ACH FOPZ.iC !Page Total op I at w`4F a oyC�,Jtl��,T- ,/ 6Q-] CX° r-� _ t ' `�``� �- IAT �-OV Tt�i .. 2,753 . 1,259 TOTAL HOURLY HEAT LOSS FOR ROOM � — ` ”" " ""' t ivl 4,013 DATE Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2014-03-12T16:49:31----.-_iD_' _ �Pag 25 of 37 O ROOM HEATING PEAK LOADS Project Name Sedona Homes 73/12/2014 Date ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Dining/Kitchen/Nook Floor Area 2,472.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 21' Q� , �, AT OF = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 2,204.0 X 0.0250 44 2,424 R-21 Wall 1,598.4 X 0.0690 44 4,853 Architectural Traditions Windows 464.0 X 0.3900 44 7,962 Laminated Entry Door 40.0 X X 0.9400 44 1,654 Wood Door 21.6 1.4500 44 1,378 Slab -On -Grade perim = 183.0 X 0.7300 44 5,878 X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,472 X1 Area to another room 13.61X(' '0. Ceiling Heicfht — ""-AEH Page Total 60��-•-j ���°a4'4;�_ � - AT iE7Y 24,150 8,171 ° ' � DEPT. TOTAL HOURLY HEAT LOSS FOR ROOM UUNSTPI IC—TI—pp, 32,321 I DA F ' Ene Pro 5.1 6 Ene Soft User Number: 6712 Run Code: 2014-03-12T164931 /D BY P ge 26 of 37 J ROOM HEATING PEAK LOADS Project Name7311212014 Sedona Homes ate ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 812.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT'F = c _ = = = = = = = = = = = = = = = = = = = = = = = = = = Qt4 Btu/hr R-38 Roof Attic 812.0 0.0250 44 893 R-21 Wall 1,013.0 0.0690 44 3,075 Architectural Traditions Windows 247.0 0.3900 44 4,239 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 812 X Area another room 8.50 X/ Height ' Page Total 601lFX _A ING uc c„'FLT-IFY 8,207 �� 2684 DEPT. ff(U TOTAL HOURLY HEAT LOSS FOR ROOM FOR Q0WFTPI 1&-10 891 I� I tPgL,27 Energ Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2014-03-12716:49:31 „I IDS_ By f 37 �J E91 C ROOM HEATING PEAK LOADS Project Name Sedona Homes Date 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 528.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4? -4 AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = t 144 ° ° DEPT. - Btu/hr R-38 Roof Attic 528.0 X X 0.0250 44 581 R-21 Wall 925.0 0.0690 44 2,808 Architectural Traditions Windows 135.0 X 0.3900 44 2,317 Slab -On -Grade perim = 102.0 X X 0.7300 44 3,276 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 528 X I Area Ceiling another room 10.00 X(�0 Height c ACH BUILDING Page Total C6O-] L5A1I n- & SAFETY n Fri r,�\ .,_ c 8,982 �-- 1,745 v I /-AE3U TOTAL HOURLY HEAT LOSS FOR ROOM v �--' 0 727 QR GGr'S R � .� � r� lJ C Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 201403-12T16:49 3 /D: Page 28 of 37 01 U RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,003.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (N) 926.0 X 0.0250 X 56.0 = 1,296 R-21 Wall (N) 465.0 X 0.0690 X 25.7 = 824 R-21 Wall (E) 194.0 X 0.0690 X 32.1 = 430 R-21 Wall (S) 140.0 X 0.0690 X 28.2 = 273 R-21 Wall (lM 60.0 X 0.0690 X 31.8 = 132 X X = X X = X X = X X = Pale Total 2,954 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 22.3 + 20.0 ,~ 27.8 = 557 Window (N) 0.0 X 22.3 + 12.5 X 27.8 = 348 Window (N) 0.0 X 22.3 + 12.5 X 27.8 = 348 Window (E) 0.0 X 22.3 + 24.0 X 43.7 = 1,049 Window (E) 0.0 X 22.3 + 48.0 X 43.7 = 2,098 Window (E) 0.0 X 22.3 + 24.0 X 43.7 = 1,049 X + X - X + X - X + X - Page Total 5,44s Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,600 Btu - 0 Infiltration: 1.064 X 1.16 X 54.88 X 34 = 2,308 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,942 Latent Gain Btu/hr Occupants 1.0 Occupants X 200=, gt- uh/occ. -�--1�-200 Yas i P y I Y �,,�- fi Y 1 �1 T� Infiltration: X 1.16 X 54.88 X 0.00276 = BUILDING & SAFETYnFPT 84 Sensible Air Sensible CFM ELA AW A; s 1:10 i`i - TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I ., �' �' I I 1,0,1 EnemvPro 5.1 by Ene-mySoft User Number: 6712 Run Code: 2014-03-12716:49:31 py Pace 20 of 7 0 O CEO RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Namee Dat Sedona Homes 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 381.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (N) 225.0 X 0.0690 X 25.7 = 398 R-21 Wall (lM 113.0 X 0.0690 X 31.8 = 248 X X = X X = X X = X X = X X = X X = X X = Page Total 646 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 22.3 + 12.5 : 27.8 = 348 Window (N) 0.0 X 22.3 + 12.5 X 27.8 = 348 Window (tM 0.0 X 22.3 + 6.0 X 40.7 = 244 Window (W) 0.0 X 22.3 + 6.0 Z 40.7 = 244 X + Z - X + : - X + - X + : - X + a - Page Total 1,185 Internal Gain Btu/hr Occupants 1.0 Occupants X_:7A Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X Btu = 0 Infiltration: 1.064 X 1.16 X 20.85 X 34 = 877 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 2,938 Latent Gain Btu/hr Occupants 1.0 Occupants X 1 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 20.85 X0.00276TY OF pp�,1 319 Air Sensible CFM ELA pW ��- U 1 B V�6'� D�!)s r� -T SAF DE T. TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 14 } •' 519 FOP: f"11 t ^"rest�an-r; EnerovPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-03-12T16:.49:31 ID: ' Pa 30 of 37 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Sedona Homes ROOM INFORMATION DESIGN CONDITIONS Room Name GreabDining/Kitchen/Nook Outdoor Dry Bulb Temperature Floor Area 2,472.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranoe: Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Wood Door Orientation (WM Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) 3/12/2014 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,204.01 0.0250 56.0 138.0 0.0690 25.7 363.0 0.0690 32.1 731.0 0.0690 28.2 366.4 0.0690 31.8 21.6 1.4500 31.8 0.0 22.3 4.0 26.3 0.0 22.3 4.0 26.3 0.0 22.3 4.0 Page Total Fenestratinn Window Window Window Window Window Window Window Window Window Orientation (N) (E) (E) (S) (S) (S) (S) (S) (S) Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 3,086 244 804 1,424 803 995 1 7,3561 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X :X X X X GLF = = = c = - = = = 0.0 22.3 40.0 27.8 185.0 22.3 0.0 43.7 0.0 22.3 40.0 43.7 0.0 22.3 40.0 26.3 0.0 22.3 4.0 26.3 0.0 22.3 4.0 26.3 0.0 22.3 4.0 26.3 22.3 12.0 26.3 10.0 0.0 22.3 1 4.01 26.3 Page Total Internal Gain 0.0 Occupants X 230 Btuh/occ 0.0 Dwelling Unit X 1,600 Btu • I Infiltration: 1.064 X 1.16 X 135.27 X 34 = Air Sensible CFM ELA AT Btu/hr 1,114 4,120 1,748 1,053 105 105 105 316 105 8, 772 Btu/hr 0 5,689 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,i Latent Gain Btu/hr Occupants o.0 Occupants X 200 Bt_ uh/occ. �� D D D _kYlnil�7[�� �j11 ' A2,6Infiltration: 4,771 X 1.16 XX 0.00276 - Air Sensible CFM ELA AW -•1���ETY DEPT. TOTAL HOURLY LATENT HEAT GAIN FOR ROOM t'',0 rte. . Jr, -" ') n C!] RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name --7 Date p 6c Homes 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Dining/Kitchen/Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 2,472.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF _ _ = _ = = = = = 0.0 22.3 12.0 26.3 0.0 22.3 4.0 26.3 0.0 22.3 12.5 26.3 0.0 22.3 12.5 26.3 0.0 22.3 16.0 40.7 0.0 22.3 4.0 40.7 0.0 22.3 40.0 Page Total Fenestration Mindow Mindow Window Mindow Window Window t/Vindow Window Window Orientation Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area X X X X X :X X X X GLF _ _ = _ = = = = = 0.0 22.3 12.0 26.3 0.0 22.3 4.0 26.3 0.0 22.3 12.5 26.3 0.0 22.3 12.5 26.3 0.0 22.3 16.0 40.7 0.0 22.3 4.0 40.7 0.0 22.3 40.0 40.7 0.0 22.3 16.0 40.7 0.0 22.3 4.0 40.7 Page Total Btu/hr 9❑ Btu/hr 316 105 329 329 651 163 1,628 651 163 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 135.27 X 34 = 5,689 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,763 Latent Gain Btu/hr Occupants o•o Occupants X 50, -uh/o Y OF LA s r� Infiltration: 4,771 X 1.16 X 135.27 X o.0027s - BUILDING & SAFETY QEPT2,o Air Sensible CFM ELA AW A ROVED TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ' " n C C C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7311212014 ate Sedona Homes ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Dining/Kitchen/Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 2,472.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area 1.1 -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshe.ded Fenestration Orientation Area GLF Area GLF Btu/hr Window (tM 0.0 X 34.8 + 40.0 .K 55.1 = 2,203 Window (tM 0.0 X 22.3 + 10.0 x 40.7 = 407 t r X + K - X + K - X + x - x x — x x — x x — x XI — Page Total 2,611 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ.. = do Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 x 1.16 X 135.27 x 34 = 5,689 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,763 Latent Gain1-7-77--— Btu/hr Occupants o•o Occupants X U 1200 Btuh"/o_cd o BU)LDi^NO & SAFETY QE Infiltration: 4,771 x 1.16 X 135.27 X 0.00276 = `, ". Ir �T2.072 Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM DATE 13 EnemvPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2014-03-12T16:49:31---4 • Pae of 37 L RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 812.0 f 2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 °F ODaaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X C -TD' = = = = = = = = = 812.0 0.0250 56.0 256.0 0.0690 25.7 285.0 0.0690 32.1 209.0 0.0690 28.2 263.01 0.0690 31.8 22.3 0.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 Page Total Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (E) (E) (E) (E) (E) (S) (S) Shaded Unshaded 1 3,2051 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF _ _ _ = = _ c 0.0 22.3 12.5 27.8 0.0 22.3 12.5 27.8 40.0 22.3 0.0 43.7 6.0 22.3 0.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 26.3 0.0 22.3 6.0 Page Total Btu/hr 348 348 891 134 262 262 262 158 158 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. Equipment 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.16 X 44.43 X 34 = 1,869 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13.4371 Latent Gain C1 0' LA QUI t�r Occupants 2.o Occupants X 20'0 1BtLih/occ & �'� � --PT. a APPROVED Infiltration: 4,771 X 1.16 X x4.43 X o.0027s = FOR CONSTNUCTI� Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM C C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 812.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (S) 0.0 X 22.3 + 10.0 X 26.3 = 263 Window (S) 0.0 X 22.3 + 40.0 :{ 26.3 = 1,053 Window (S) 0.0 X 22.3 + 10.0 X 26.3 = 263 Window (W) 0.0 X 22.3 + 6.0 .K 40.7 = 244 Window (W) 0.0 X 22.3 + 20.0 K 40.7 = 814 Window (W) 0.0 X 22.3 + 40.01 K 40.7 = 1,628 Window (IM 0.0 X 22.3 + 20.0 X 40.7 = 814 X + X - X + X - Page Total 5,080 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ- = 460 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 44.43 X 34 = 1,869 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,437 Latent Gain , ,a �� �- LA i! / r � E Occupants 2.0 Occupants X 00 g h% ec:, 400 Infiltration: 4,771 X 1.16 X 44.43 X 0.00276 = o-,;& r- 1A 681 Air Sensible CFM ELA AW FOR CONSTRUCTS I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM„� 1 �81 i ----- Ene Pro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2014-03-12716:49:31 Page 35 of 37 J I RESIDENTIAL ROOM COOLING LOAD SUMMARY I vroiect Name Date Sedona Homes 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 528.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: 34 OF Or)aaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 528.0 0.0250 56.0 268.0 0.0690 25.7 164.0 0.0690 32.1 298.0 0.0690 28.2 195.0 0.0690 31.8 22.3 6.0 27.8 0.0 22.3 10.0 43.7 0.0 22.3 40.0 43.7 0.0 22.3 6.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Internal Gain Orientation (N) (N) (N) (N) (E) (E) (E) (S) (S) Btu/hr 739 475 363 580 1 2,5851 Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area ={ X "{ K K X X X X GLF = = = = = = = = 0.0 22.3 24.0 27.8 0.0 22.3 6.0 27.8 0.0 22.3 6.0 27.8 0.0 22.3 6.0 27.8 0.0 22.3 10.0 43.7 0.0 22.3 40.0 43.7 0.0 22.3 6.0 43.7 0.0 22.3 6.0 26.3 0.0 22.3 6.0 26.3 Page Total 1.0 Occupants X 230 Btuh/occ.. 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.16 X 28.89 X 34 = Air Sensible CFM ELA AT Btu/hr 668 167 167 167 437 1,748 262 158 158 3,9331 Btu/hr c 230 0 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8.9811 Latent Gain _ �_tU Occupants 1.0 Occupants X 200 J`gtuli/o3cc.F CLL [(-�-�U� NITA B�J1Lftit�i (Y J�ii-� 1 i Infiltration: 4,771 X 1.16 X 28.89 X 0.00276 = Air Sensible CFM ELA AW j;-�•a I ROVED 401 FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I FAA rw RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 3/12/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 528.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 0.0 X 22.3 + 25.0 X 40.7 c 1,018 X + X — X + X - X + X - x x - x x - x x - x x - x XI - Page Total 1.018 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 x 1.16 x 28.89 x 34 = 1,215 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,981 Latent Gain Btu/hr Occupants 1.0 Occupants X ,200-_Btuh/.eco P� t 'Y' LA QUI I 00 t "e.J' r a�-, 1, Infiltration: 4,771 x 1.16 x 28.89 x 0.00276 = BUILDING & SAFETY ;EPI. 43 Air Sensible CFM EIA AW AF PROVE I FOR r)Kl. TOTAL HOURLY LATENT HEAT GAIN FOR ROOML43 Ener Pro 5.1 6 Ene Soft User Number. 6712 RunCode: 2014-03-12716:49:31 DAT/x B e -37-o 37 Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition.'Alteration Date 3/13/2014 Project Address Hideaway Lot #27D La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,196 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 92 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,470 Radiant Barrier New Wall Wood Framed R-21 4,733 New Slab Unheated Slab -on -Grade None 4,384 Perim = 419' New Door Opaque Door None 22V%§0^CJJJV1JNew MAR 2 A 2014 Crry Of A QUIN" FENESTRATION U- C0tQ4UNi @ff Orientation Area(ft`) Factor SHGC Overhang Sidefins Shades Status Left (N) 137.0 0.390 0.39 none none Bug Screen New Rear (E)210.0 0.390 _ 0.39 none none Bug Screen New Front (Ko 213.0 0.390 , 0.39 none none Bug Screen New Left (N) 1!40.0 / 0.390 0.39 14.0 none Bug Screen New Rear (E) /`' 185.0 0.390 0.39 18.0 _ none Bug Screen New Right (S) '193.0 10.390 0.39 none .,none r- BugFScrf_ A New FrontI (VV) 40.0 0.940 I i L�Br-1 re. 1'4 0.43 none no a ug,Scren _ New Rear (E) 46.0 0.390 0.39 11.0 1 Hones "' `7 '`1 ') Bug1 Screen c -New /A r' f- f` tr_:1l C UFS 'Uiv,,:) i i-YU I IUN 10 off, HVAC SYSTEMS Qty. Heating Min. Eff DATE BY Cooling ostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setbact New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setbacr New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback: New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 9.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATINGr Qt . Type Gallons Min. Eff Distribution '• 117, --; t tus 1 Large Gas 100 0.80 All Pipes Ins r:4 rNe I - (� 1i�,. • 1, T;n EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2014-03-12716:49:31 ID: a e 1 of 10 Reg: 213-N0089677B-000000000-0000 Registration Late/Time: 2013/12/02 10737:53---..HER$_Pr=i�ider: CaTCER�I Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 E],Qctronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additior/Alteration Date 3/13/2014 Project Address Hideaway Lot #27D La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,196 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(fr) Factor SHGC Overhang Sidefins Shades Status ..mac... --_ - — •c---,—�• .-•-tee-... r�-.-�..�•-� ..a -+e.._ 17 V HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING FC Qty.Type Gallons Min. Eff Distributiony.0 �-'� i,yUINIS t s N _ �:�., •, �Y ;, ,� f 1' EP DEPT- - '•J (. ,., - • ' YY• = n EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-12T16 49:31' - --ID--pry of 10 Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 1` 0: 37:53r H RS—Pr-) �- a10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family ❑ Existing+ Addition/Alteration 3/13/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies tased on the adequacy of the special 'ustification and documentation submitted. The DHW System Bradford White M-I-100S6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 20 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 690.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 313.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 306.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 75.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 41) sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 234.0 ft2 Covered Slab Floor, 3.500" thick at GreabDining/Kitchen/Nook HIGH MASS Design - Verify Thermal Mass: 2,238.0 ft2 Exposed Slab Floor, 3.500" thick at Great/Dining/Kitchen/Nook The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3 3 must be met. The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix Rf:3.3 must be met. HIGH MASS. Design Verify Thermal Mass: 282.0 ft2 Covered Slab'Floor, 3.500" thick at Casita / I� Y } f HIGH MASS Design - Verify Thermal #Mass: 246.0 ft2 Exposed Slab Floor, 3.500" thick at Casita HERS REQUIRED VERIFICATION Items in this section require field te`stirig and/or verification by a certified HERS Rater-The'in`spe �or,m st receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA548 / 58CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA548 / 58CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rate must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA536 / 58CVX070 includes credit for a 12.9 EER Condenser. A certified HERS rates must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS verified Duct leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 24APA524 / 58CVX070 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. lll! P'N, 0, R. CBC1C?-y faD FOR COrISTRUCTION Ene Pro 5.1 by Enem YSoft User Number: 6712 Run Code: 2014-03-12716:49:31 ID: Page 3 of 10 ' UHIt BY Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 H Pr�vider:CR RTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family ❑ Existing+ Addition/Alteration 1 3/13/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation critepia as specified in Residential ADDendix RA4.2.2. HERS REQUIRED }V ERIFICATION 4 '07or' W Items in this section require field testing and/or verification'by a certified'HERS Rater^The'inspector,must receive a completed CF -4R form for each of the measures listed below for final to be given. User O� R �� ✓ y� y� - yi ^rF 1F it �KLA 'e-', R yi / y A R R � A f..� l 0 BUILDING, 8,, ;I -SAFETY IDFPT n =R.\!�D F -UH GONS T RU TION 16.49:31 /D: It Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: Ca CERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS. com by Antnn MAri nknvi rh !.quart- T„r i n /i z /,3ni a PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Proiect Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family ❑ Existing+Additim/Alteration 1 3/13/2014 ANNUAL ENERGY USE SUMMARY TDV kBtu/ft2- r Space Heating 4.95 4.52 0.43 Space Cooling 54.07 49.68 4.39 Fans 10.92 14.44 -3.52 Domestic Hot Water 6.61 4.35 2.26 Pumps 0.00 0.00 0.00 Totals 76.55 72.98 3.57 Percent Better Than Standard: (E) 4.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 3/132014 City/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building enve�ope sealing require installer testing and certification and field verification by an approved -KERS -rater. Designer or Owner (per Business & Professions Cod) CI*Ty Or Uiw rA Company _ sTRACTS, Inc. BUILDING & SAFETY DEPT. Address 550 S. Oleander Name Anton Marin pvich A y�Rr) �/ City/State/Zip Palm Springs, CA 92264 Phone (760) 636-89I¢1 FOR C%! 16d�UGTIONicense Date Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: CalCERTS, Inc r-enestratlon Building Front Orientation: (M 290 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tM 1,272 253 Fuel Available at Site: /Natural Gas (N) 1,529 177 Raised Floor Area: 0 (E) 1,447 441 Slab on Grade Area: 4,384 (S) 1,571 193 Average Ceiling Height: 11.3 Roof 4,470 0 Fenestration Average U -Factor: 0.41 TOTAL: 1,064 Average SHGC: 0.39 Fenestration/CFA :Ratio: 20.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 3/132014 City/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building enve�ope sealing require installer testing and certification and field verification by an approved -KERS -rater. Designer or Owner (per Business & Professions Cod) CI*Ty Or Uiw rA Company _ sTRACTS, Inc. BUILDING & SAFETY DEPT. Address 550 S. Oleander Name Anton Marin pvich A y�Rr) �/ City/State/Zip Palm Springs, CA 92264 Phone (760) 636-89I¢1 FOR C%! 16d�UGTIONicense Date Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additi)n/Alteration Date 1311312014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Append,x Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 926 0.025 R-38 0 0 New 4.2.1-A21 Master Bedroom Wall 465 0.069 R-21 20 90 New 4.3.1-A6 Master Bedroom Wall 194 0.069 R-21 110 90 New 4.3.1-A6 Master Bedroom Wall 140 0.069 R-21 200 90 New 4.3.1-A6 Master Bedroom Wall 60 0.069 R-21 290 90 New 4.3.1-A6 Master Bedroom Slab 690 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 313 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Wall 225 0.069 R-21 20 90 New 4.3.1-A6 Bedroom 2 Wall 113 0.069 R-21 290 90 New 4.3.1-A6 Bedroom 2 Slab 306 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 75 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 2,204 0.025 R-38 0 0 New 4.2.1-A21 Great/Dinin /Kitchen/Noo Wall 138 0.069 R-21 20 90 New 4.3.1-A6 Great/Dinin /Kitchen/Noo Wall 363 0.069 R-21 110 90 New 4.3.1-A6 Great/Dinin /Kitchen/Noo Wall 731 0.069 R-21 200 90 New 4.3.1-A6 1Great/Dinin /Kitchen/fool Wall 366 0.069 1 R-21 290 90 New 14.3.1-A6 Great/Dining/Kitchen/fool FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 20.0 0.390 NFRC 0.39 1 NFRC 20 New Architectural Traditions WindovL Master Bedroom 2 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windo Master Bedroom 3 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windom Master Bedroom 4 Window 24.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window Master Bedroom 5 Window_ -1-, 48.0 0.390 NFRC 0.39 NFRC 110 New . _ Architectural Traditions Window Master Bedroom 6 Window` N 24.0 0.390 NFRC f 0.39 NFRC 110 New Architectural Traditions Window Master Bedroom 7 Window `12.5 0.390 NFRC r' 0.39 'NFRC 20 New Architectural Traditions Window Bedroom 2 8 Window 12.5 :;0.390 NFRC 0.39 NFRC ..-4 20 New Architectural Traditions,Windovr Bedroom 2 9 Window 6.0 / 0.390 NFRC 0.39 NFRC 1 290 New Architectural Traditions WindoYr Bedroom 2, 10 Window 41 6.0 a 0.390 NFRC 0.39 NFRC 1290 New. t Architectural Traditions WindoYr Bedroom 2 11 Window. ► 9,40.0 -0.390 NFRC- ---#0.39 NFRC,.- a 20 New Architectural Traditions WindoK GreabDining/Kitchen/Nook 12 Window 185.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window, GreaUDining/Kitchen/Nook 13 Window 40.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window., GreaUDining/Kitchen/Nook 14 Window 40.0 0.390 1 NFRC 0.39 NFRC 200 New Architectural Traditions Windows Great/Dining/Kitchen/Nook 15 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window+ GreaUDining/Kitchen/Nook 16 Window 4.0 0.390 NFRC 1 0.39 NFRC 200 New Architectural Traditions Windowl GreatlDining/Kitchen/Nook (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bvq Screen 0.76 _ 11 Bug Screen 0.76 8.01 5.0 14.0 0.1 14.0 �1,4 0 i F- �`►! I I I 12 Bug Screen 0.76 10.01 18.5 18.0 0.1 18.0 M18:0r-.., 13 Bu Screen 0.76 "''" "� �� +� Ct 14 Bug Screen 0.76 15 IBug Screen 0.76 16 JBug Screen 0.76 7i Y ver��e� Y rcr i (Vj DATE RV EnergyPro 5.1 by EnefgySoft User Number. 6712 RunCode: 201403-12T116;49a _.._._ JjD age 6 of 10 Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+Additim/Alteration Date 1311312014 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Append'x Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Door 22 1.450 None 290 90 New 4.5.1-A1 Great/Dinin /Kitchen/Noo Slab 234 0.730 None 0 180 New 4.4.7-A 1 Great/Dinin /Kitchen/Noo Slab 2,238 0.730 None 0 180 New 4.4.7-A1 Great/Dinin /Kitchen/Noo Roof 812 0.025 R-38 0 0 New 4.2.1-A21 2nd Floor Wall 256 0.069 R-21 20 90 New 4.3.1-A6 2nd Floor Wall 285 0.069 R-21 110 90 New 4.3.1-A6 2nd Floor Wall 209 0.069 R-21 200 90 New 4.3.1-A6 2nd Floor Wall 263 0.069 R-21 290 90 New 4.3.1-A6 2nd Floor Roof 528 0.025 R-38 0 0 New 4.2.1-A21 Casita Wall 268 0.069 R-21 20 90 New 4.3.1-A6 Casita Wall 164 0.069 R-21 110 90 New 4.3.1-A6 Casita Wall 298 0.069 R-21 200 90 1 New 4.3.1-A6 Casita Wall 195 0.069 R-21 290 90 New 4.3.1-A6 Casita Slab 282 0.730 None 0 180 New 4.4.7-A1 Casita Slab 246 0.730 1 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC4 Azm Status Glazing Type Location/Comments 17 Window 4.0 0.390 1 NFRC 0.39 NFRC 200 New Architectural Traditions Window Great/Dining/Kitchen/Nook 18 Window 12.0 0.390 1 NFRC 0.39 NFRC 200 New Architectural Traditions Window GreatlDining/Kitchen/Nook 19 Window 4.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Windor, GreatlDining/Kitchen/Nook 20 Window 12.0 0.390 NFRC 0.39 NFRC 200 New Architectural Traditions Window Great/Dining/Kitchen/Nook 21 Window,_ ` 4.0 0.390 NFRC ,0.39 NFRC 200 New _ .__ - Architectural Traditions Window. GreabDining/Kitchen/Nook 22 Window' I 'x,12.5 0.390 NFRC % 0.39 NFRC 200 New i Architectural Traditions, Window. GreabDining/Kitchen/Nook 23 Window • 12.5 0.390 NFRC ! 0.39 'NFRC 200 New . Architectural Traditions Window GreabDining/Kitchen/Nook 24 Window 16.0 0"0.390 NFRC 0.39 NFRC x.4290 New. Architectural Traditions+Window GreabDining/Kitchen/Nook 25 Window _4.0 /0.390 NFRC 0.39 NFRC V 290 New Architectural,TraditionsWindov GreabDining/Kitchen/Nook 26 Window 4 140.0, 1 0.390 NFRC 0.39 NFRC 290 New 1 Architectural •Traditions Window. GreabDining/Kitchen/Nook 27 Window. f 0.16.0 -0.390 NFRC • 0.39 NFRC -r�290 New R Architectural,Traditions;Windov Great/Dining/Kitchen/Nook 28 Window 4.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window Great/Dining/Kitchen/Nook 29 Window _ 40.0 0.940 NFRC 0.43 NFRC 290 New Laminated Entry Door Great/Dining/Kitchen/Nook 30 . Window 10.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window GreabDining/Kitchen/Nook 31 Window 12.5 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window, 2nd Floor 32 Window 12.51 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windoav 2nd Floor (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len Hot Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76-1-- 26 Buq Screen 0.76 ,1 Y' q" t_ I A f I I A 1 27 Bug Screen 0.76 „ n - _ - ' - r 28 Bug Screen 0.76 L1 t_ I lr C _ 29 Bug Screen 0.76 30 Bug Screen 0.76 t �' •�' r. r- 31 Bu Screen 0.76 �'"'� FiL1t; ION. 32 Bu Screen 0.76 DATE �_ Bti- Ene Pro 5.1 b Ene Soft User Number: 6712 Run Code: 2014-03-12T16:49:31 ID: a e 7 of 10 Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS PrDvider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 3/13/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 ,of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1311312014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 40.0 0.390 NFRC 0.39 1 NFRC 110 New Architectural Traditions Windom 2nd Floor 34 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 35 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window 2nd Floor 36 Window 6.0 0.390 NFRC 0.39 NFRC 110 New Architectural Traditions Window. 2nd Floor 37 Window_,-- ,_•_ 6.0 0.390 NFRC 0.39 NFRC 110 New, _ _ Architectural Traditions Window- 2nd Floor 38 Window. 'N/ 6.0 0.390 NFRC ,.+ % 0.39 NFRC -200 New L._ I Architectural Traditions +Window 2nd Floor 39 tVIndow, , ' 6.0 0.390 NFRC _ A 0.39 'NFRC 200 New., , Architectural Traditions Window, 2nd Floor 40 Window 10.Q 60.390 NFRC.( 0.39 NFRC -4200 New, -,oP Architectural TraditionsiWindow, 2nd Floor 41 Window 40.0 10.390 NFRC 0.39 NFRC 9 200 New 3 4 ArchitecturalTTraditions Window, 2nd Floor.., 42 Window 4 i10.0, 1.0.390 NFRC 0.39 NFRC , 200 Newer. ->L • Architectural, Traditions Window 2nd Floor lr !! 43 Windowr41' 46.0 _.0.390 NFRC- X0:39 NFRC,-'-., !S'290 New ArchitecturabTraditions,Window, 2nd Floor YVwo!! 44 Window 20.0 0.390 NFRC 0.39 NFRC" 290 New Architectural Traditions Window, 2nd Floor 45 Window 40.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window, 2nd Floor 46 , Window '20.0 0.390 NFRC 0.39 NFRC 290 New Architectural Traditions Window, 2nd Floor 47 Window 24.0 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Window Casita 48 Window 6.0 • 0.390 NFRC 0.39 NFRC 20 New Architectural Traditions Windowl Casita (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 8.01 5.0 11.0 0.1 11.0 11.0 34 Bug Screen 0.76 3.01 2.0 11.0 0.1 11.0 11.0 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 t ; u M M 44 Bug Screen 0.76 +l) h?;�,r� rr. Q -A1 r -v r 45 Bug Screen 0.76 - -' 46 Bug Screen 0.76 47 IBug Screen 0.76F..� r,s-s E;� 48 Bu Screen 0.76 ' '" 'E N 1 DATE gY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-12T16:4"1------40-----Lade 8 of 70 Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 Electronically Sianed at Calr'RRTR rnm by nntnn M—inlrnvinh tQt- tc Tnn 1 1/iz/�nin CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1311312014 OPAQUE SURFACE DETAILS SurfaceU Insulation Joint Appendix T e Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS Screen ID Type Area U -Factor SHGC 49 Window 6.0 0.390 NFRC 0.39 NFRC 50 Window 6.0 0.390 NFRC 0.39 NFRC 51 Window 10.0 0.390 NFRC 0.39 NFRC 52 Window 40.0 0.390 NFRC 0.39 NFRC 53 Window.,_,,, - 6.0 0.390 NFRC 0.39 NFRC 54 Window' Nti 6.0 0.390 1 NFRC ,r / 0.39 NFRC 55 Window 6.0 0.390 NFRC r 0.39 'NFRC 56 Window 25.Q -0.390 NFRC 0.39 NFRC .If / / f t I 1 4P •) ' ,f. �' 1 Azm Stag 20 New 20 New 110 New 110 New 110 New 200 New ! 200 New —4290 New V J , � r Glazing Type Architectural Traditions Architectural Traditions Architectural Traditions Architectural Traditions Architectural Traditions Architectural Traditions` Architectural Traditions Architectural Traditionsi i idoviz Casita ido ' Casita ldo : Casita 7dom Casita 7dow Casita 1doN Casita ldovr. Casita idovr Casita on/Comments (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Overhang Left Fin Right Fin ID Exterior Shade Type SHGC I H t Wd Len H t LExt RExt__1 Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Buq Screen 0.76 Screen 0.76 Screen 0.76 Screen 0.76 Screen 0.76 Screen 0.76 Screen 0.76 I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014.03-12T1t6:4O:31- !D: BY Oaoe 9 of 10 11-1. — _,,,.. „ �-���������-���� RCyL�lLdl1VII LdLe/liMe: LVld/1L/VL 1V:3/:73 kiERS Yroviaer: CaiCERTS, inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/13/2014 El*ctronically Sinned at ra1rRRTR — h„ n„t— M.,-;,L—,i,1, re« «a T-- i CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Sedona Homes Building Type ❑ Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addit on/Alteration Date 3/13/2014 BUILDING ZONE INFORMATION 11 �J 114 System Name Qty. Heating Type System Name Zone Name Floor Area New Existinq Altered I Removed Volume Year Built HVAC 1 Master Bedroom 1,003 10,231 New Bedroom 2 381 3,810 HVAC 2 & 3 GreatlDiningA<itchen/Nook 2,472 32,630 80%-AFUE Split Air Conditioner= 15.0 SEER Setback HVAC 4 2nd or 812 6,902 1 t Central Furnace HVAC 5 1 Casita 5281 1 5,280 MULTI -FAMILY WATER HEATING DETAILS Hot Water Piping Length nl o -0 Control Qty. HP Plenum Outside Buried a C HEATING SYSTEM PIPING CITY OF BUILDING & S stem Namej;,L`en Totals 1 5,1961 01 01 0 ;° cPR.,PT. DIIAmeter r 4,w H HVAC SYSTEMS .. 1..I I 1 VY' --- 1 I-IU'U 11 �J 114 System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 - . 1 _ Central.Furnace," 80%-AFUE Split Air Conditioner= 15.0 SEER Setback New HVAC 517 r 1 t Central Furnace 80% AFUE Split �4ii Conditioner ) 15.5 SEER Setback New r HVAC DISTRIBUTION f s. �/ �. System Name �. <•f-- rljeafinq _ � r" `�. s,**Ir,--,, A 0' :;,*eDuct.TL,,' V Ducts�rQ 'Cooling Duct Location R-Vabe Tested? Status HVAC 1 _ Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.01 m New El WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White M -1-100S6 1 Large Gas All Pipes Ins 90,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS Hot Water Piping Length nl o -0 Control Qty. HP Plenum Outside Buried a C HEATING SYSTEM PIPING CITY OF BUILDING & S stem Namej;,L`en LA C%UINTA S." ape T thr ;° cPR.,PT. DIIAmeter r 4,w H :i —e .. 1..I I 1 VY' --- 1 I-IU'U 11 �J 114 DATE BY nsul. hick. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014.03-12716:49:31 ID: Pae 10 of 10 Reg: 213-N0089677B-000000000-0000 Registration Date/Time: 2013/12/02 10:37:53 HERS Provider: CalCERTS, Inc