Loading...
04-6782 (SFD).14 P.O. Box 1504 �F f9 - LLE TAMPICO p1� CALIFORNIA 92253 D I APR 2 $ 2005 BUILDING PERMIT Application description . . Property Zoning . . . . . . Application valuation Owner ------------------------ MICHAEL INCS,rrE?,, 20600 LOMITA AVE. SARATOGA CA 95070 BUILDING & SAFETY DEPARTMENT (760),777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 r04-0,0006782 Date 1/28/05 53697 -VIA DONA 772-420-999-35 -298944- DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL . 439787 Contractor LUDINGTON SIN GENERAL CONTR 45120 SAN PABLO, STE #2-I PALM DESER-' CA 92260 (760) 568-6070 WCC: SATE FUND WC: 1423538 08/01/05 CSLB: 796780 06/30/05 CCC: B ------ Structure Information 5083 SQ: FT. SFD ----- Construction Type . . . . . TYPE V -'NON RATED Occupancy Type . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 5.00 FIRE SPRINKLERS NO GARAGE SQ FTG 989.00. PATIO SQ'FTG 729.00 NUMBER OF UNIT'S 1.00 1ST FLOOR SQUARE FOOTAGE 5083.00 ---------------------------------------------------_------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee. . . . . 1829..50 Plan Check Fee 1189.18 Issue Date . . . . Valuation_ 439787 Expiration Date 7/28/05 Qty Unit Charge Per Extension BASE FEE 639.50 340.00 3.5000 THOU BLDG 100,001-500,000 1190.00 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc 'Permit Fee . . . . 227.69 Plan Check Fee 56.92 Issue Date Valuation_ . . . . 0 Expiration Date 7/28/05 Qty Unit Charge Per Extension BASE FEE 15.00 • ��IVIf�'IN P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: Architect or Engineer: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of pedury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class / License No. Date �1�Contractor OWNER43UILDER DECLARATION I hereby affirm under penalty of perj that I exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to ruct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason t�o / Date Zr/ .0 WORKERS' COMPENSATION DECLARATION I hereby affirm under penalt)(C ne rofthe following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is is ue yvIorkers' compensation insurance carrier and olicy uriTb�,r are: Carrier 7+4 ...+,Ci Policy Number / 4•_ � S Ji _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date Applicant k_ WARNING: FAILURE TO SECUR WORKERS COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDR THOUS D DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, EST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date 4-2,cLJI0 " Signature (Applicant or Page 2 Application Number . . . . . 04-00006782 Date 1/28/05 Qty Unit -Charge Per Extension 5083.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 177.91 989.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 19.78 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit . . . ... . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/28/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL .Additional desc . . Permit Fee . . . . 139.00 Plan Check Fee 34.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/28/05 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K FTU 36.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ----------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc . . Permit Fee . . . . 244.50 Plan Check Fee 61.13 Issue Date . . . . Valuation_ . . . . 0 Expiration Date 7/28/05 Qty Unit Charge Per Extension BASE FEE 15.00 27.00 6.0000 EA PLB FIXTURE 162.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER.INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 .7500 EA PLB GAS PIPE >=5 10.50 1.00 ---------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 5083 SQ. FT. SFD THIS PERMIT DOES NOT I Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2455.69 Page 3 Application Number . . . . . 04-00006782 Date 1/28/05 ---------------------------------------------------------------------------- Special Notes and Comments INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH. 11/8/04 11:20:53 AM JJOHNSON ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 599.46 DIF COMMUNITY CEN -ERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 118.92 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SM]) - RES 43.97 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2455.69 .00 1341.98 750.00 3167.35 .00 6965.02 750..00 Credited Due .00 2455.69 .00 591.98 .00 3167.35 .00 6215.02 t� T4'1t " P.O. BOX 1504 Buildingj q-7 V�� P�n� 78-495 CALLE TAMPICO Ar1r1rPRS of v/ t LA QUINTA, CALIFORNIA 92253 Mailing o v __`i ` _ � I Address GLC/V 1 l.Tc/ Citv t _ _ Zip _ _ I Tel. _ tor Conga IlUnfif m f Uo 1< 1 r-911-70,60 Roo) SiAt 2 .State Lic. IL;I[y & Classif. Lic. # Arch., Engr Designer Y k ����� I� 5 - - UWV rt City, 6,, A -Zips State lh ils� v, - lf'7!7 f ., /1 I Lic. # G -J Pi LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to ,its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant fo a civil penalty of not more than five hundred dollars ($500). 1-: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of Completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law.) l 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company (l Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) 1 certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT APPLICATION ONLY BUILDING: TYPEE''IC�O1/N�ST./��l N OCC./GARP. MM/C\`1TJklL/ A.P. Number 1 /oC� - I I�— ✓ /}� j� Legal Descriptiona�' I Project Description I`K/V" � mz/ Sq. Ft. �JC/�J No. No. Dw. Size Stories Units New"`C Add ❑ Alter ❑ Repair ❑ Demolition ❑ imated Valuation PERMIT I n I AMOUNT Plan Chk. Dep Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure YELLOW = APPLICANT PINK = FINANCE TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property. Line S FINAL DATE �'�*� �" INSPECTOf3l , I � 4F� D l l Il Issued by: jj ft TDate Permit Validated by: �.1� ',u�I 200��� Validation: r"— ,�nr n% ► 411iM A YELLOW = APPLICANT PINK = FINANCE r Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE, RFrAIPT- CHF.CK H- INITIALS - CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is at The Hideaway Owner's Name: Mr. Michael Ingster Project Address: 53-697 Via Dona La Quinta, CA Project Description: 1 SFD APN: 772-410-004 Tract #: Date: April 28, 2005 Phone No. Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 5,083 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is :orrect and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the ownerfleveloper. Dated: April 28, 2005 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR T1=0VE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 5,083 Amount per Sq.Ft. $ 2.88 Amount Collected $ 14,639.04 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services r Certificate issued by: Elvira Mattson, Office Technician Signature: _&Atel--) NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that 9his District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 911 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and cther applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause: as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has nofl been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. !ti V:c;m�docshk� liectcertilieauc orc(mpliatnce !i)rm ulbloclTo L1Sf;.doc 1/16/03 T T4hf 4 4 Q" P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 To: Greg Butler, Building & Safety Manager From• scar Orci fanning Manager BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 Building Plans Approval (This is an approval to issue a Building Permit) To CDD: -3-8-05 Due date:3-9-05 Status: Co ✓eAAI The Community Development Department has reviewed the Building Plans for the following project: Description: Guest House Address or general location: 53697 Via Dona Applicant Contact: M/M Ingster The Community Development Department finds that: ❑ ...these Building Plans do not require Community Development Department approval. ®-� ...these Building Plans are approved by the Community Develcpment Department. ❑ '...these Building Plans require corrections. Please forward a co -Dy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. Doug Evans, Commfmity Development Department Director 0 Date AkM: MuP 71 r9e MT -W66 AWp to c,ontu*W or 49C4WPA*JV P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 October 7, 2004 Kristi Hanson 72-185 Painters Path, Suite A Palm Desert, Ca 92260 SUBJECT: MINOR USE PERMIT 2004-544 (GUEST HOUSE) (760) 777-7000 FAX (760) 777-7101 Dear Kristi: S3 69 ;;7 The Community Development Department has reviewed your request to establish a guest house on property located at -56-6 Via Dona (Lot 35D of Tract 29894-4) within The Hideaway development, and hzs approved your request subject to the following conditions: 1. Only one guest house (attached or detached) may be established per lot, in addition to the primary residence. 2. The guest. house shall be architecturally compatible with the main residence on the property. 3. The height of the guest house shall not exceed seventeen feet in height and not be more than one story. 4. The floor area of the guest house shall not exceed thirty percent of the existing living area of the primary residence and not result in violation of the lot coverage maximum. 5. There shall be no kitchen or cooking facilities within the guest house. 6. The guest house shall used only by the occuparrts of the main residence, their non-paying guests, or domestic employees. 7. The guest house shall not be rented or otherwise occupied separately from the main residence. 8. A deed restriction shall be required for recordation against the property to prohibit the use or conversion of the guest house t:) a rental unit, a 3 K. Hanson MUP 04-544 Page 2 unit for sale, or to add a kitchen or cooking facility. The attached deed restriction shall be signed, notarized and recorded at the Riverside County Assessor's Office by the property owner(s). 9. The guest house shall be hooked up to the existing sewage disposal system for the property. 10. The City may elect to addConditions to this application request to mitigate any problems that arise not previously addressed herein. This decision may be appealed to the Planning Commission by anyone provided they submit the necessary paperwork and filing fee of $175.00 with this office within 15 days of approval of this permit, which is the appeal period established under Section 9.200.120 of the Zoning Code. Please have the property owner sign, notarize and record the attached deed restriction and have a copy mailed back to us for our records. Should you have any questions or need additional information, please do not hesitate to contact me directly at (760) 777-7068. Sincerely, OSCAR ORCI, INTERIM COMMUNITY DEVELOPMENT DIRECTOR Ae C,,� "r, re. 4 MARTIN MAGANA Associate Planner C: Building & Safety Department Chron file P:\Martin\MUP's\MUP 04-544 Hanson.doc RECORDING REQUESTED BY: City of La Quinta – City Clerk's Office P. O. Box 1504 La Quinta, CA 92247-15.04 WHEN RECORDED.PLEASE MAIL TO: Michael & Stephanie Ingster 20-600 Lomita Avenue -Saratoga, Ca 95070 COVENANT DOC 8* 2005-0165614 03/02/2005 08:00A Fee:NC Page 1 of 4 Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk 8 Recorder ... IIIIIII III IIIIIII IIII II III 111111 III IIIII IIII III RESTRICTING THE USE OF THE RESIDENCE AT na , LA QUINTA, CALIFORNIA f� This covenant agreement are made and executed this day of e 6vN a , 20 05, by N1 i e S 1 , as the record owner(s) of the pro erty described herein. The City of ta Quinta, a unicipal Corporation, is hereby made a party to this agreement for the purposes set forth below. The undersigned hereby certifies that he/she is the property owner of the following described real property in the City of La Quinta, County of Riverside, State of California: Lot 35D of Tract 298944 (The Hideaway), as per record map on file with the Recorder of Riverside County In consideration of the City of La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and.agree to and with said'City to restrict the use of said property as follows: 1. The guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2004-544); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zoning District) and 9.60.110 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (i.e., a maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zoning and other codes as set forth in the La Quinta Municipal Code, as may be amended from time to time. . s U PAGE SIZE DA POOR NOCOR SMF NSC. LA R L COPY LONG REFUND NCHG EXAM RESTRICTING THE USE OF THE RESIDENCE AT na , LA QUINTA, CALIFORNIA f� This covenant agreement are made and executed this day of e 6vN a , 20 05, by N1 i e S 1 , as the record owner(s) of the pro erty described herein. The City of ta Quinta, a unicipal Corporation, is hereby made a party to this agreement for the purposes set forth below. The undersigned hereby certifies that he/she is the property owner of the following described real property in the City of La Quinta, County of Riverside, State of California: Lot 35D of Tract 298944 (The Hideaway), as per record map on file with the Recorder of Riverside County In consideration of the City of La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and.agree to and with said'City to restrict the use of said property as follows: 1. The guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2004-544); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zoning District) and 9.60.110 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (i.e., a maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zoning and other codes as set forth in the La Quinta Municipal Code, as may be amended from time to time. fR.. This covenant and agreement shall run with the land and shall be binding upon future owners, their successors, heirs, or assigns, and ourselves, and shall continue in effect while said accessory building remains on the real property or unless otherwise Mgased by the authority of the City of La Quinta. All leases of said dwelling and/or property''shai be subject to this restriction. This agreement shall be entitled to the remedy of injunctive.ielief in addition of any remedy in law or equity. This covenant and agreement and the provisions hereof are irrevocable, except by the written consent of all parties to the agreement, including the City of La Quinta, a municipal corporation. The City shall have the right to enforce each and every provision hereof and the parties agree that the agreement shall not be rescinded, revoked, modified, or otherwise amended or changed, without the expressed written consent of the City first being obtained. . In the event that the owners, their heirs, assigns or successors in interest, shall fail to perform any obligation hereunder, they hereby agree to pay all costs and expenses incurred by the City of La Quinta in securing performance of such obligation, including attorney's fees: By: 1. I �.. Michael Ingster 2. Stephanie Ingster 3. 4. Signature(s) Printed Name(s) Dated: > Approved as to form: Oscar W. Orci Interim Community Development Director City of La Quinta Dated: r/Zi'!? se- ALL e ALL PURPOSE NOTARY ACKNOWLEDGMENT(S) MUST BE ATTACHED IN 8-1/2 X 11" FORMAT, FOR EACH SIGNATURE. STATE OF CALIFORNIA ) COUNTY OF RIVERSIDE) ss. CITY OF LA QUINTA ) 1 1 On B1 aoo L , before me,-i}.o Personally appeared 1ks. nc�, personally known to a or proved to me on the basis of satisfactory evidence to be the peson(s) whose name(s) is/are subscribed to the within instrument and acknowledged to meAhat lie/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal, QuL' &,�-w- Signature of the gotai4 Publiclo PHYLLJS MANLEY CgnrraMn #1376 IVotCrY PJ400 - C0 ftm'O ' Mmoe County Cbmrn EgIresQct'14.2006 CALIFORNIA ALL-PURPOSE ACKNOWLEDGMENT State of California - County of : Sa v -t - On E,y,V2 3i ZooS before me,�Qruyf , Date Name and Title of Ofrt r (e.g., 'Jane Doe, Notary Public') personally appeared S{�Ohmie_ Twj-, � Name(s) of Signer(s) SARAH L�ZSANNIEL C10MM W 1140 =531 _ Pbtory Pubic-600MIO Santo acro County_. AllyCon,ME4pMNb15► ❑ personally known to me jk proved to me on the basis of satisfactory, evidence to be the person(sy whose name(s) is/are subscribed to the within instrument and acknowledged to me that He/she/they executed the same in bis/her/tha=t authorized capacity(jW, and that by ftis/her/their signature(* -on the instrument the person(,sr), or the entity upon behalf of which the personal acted, executed the instrument. WITNESS my hand an ficial seal. of Notary Public OPTIONAL Though the information below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent removal and reattachment of this form to another document. Description of Attached Document Tit e or Type of Document: �D� d �//��' `'� 9_,e#tGif/� * IL Document Date: Z/23/ e4' Number of Pages: Signer(s) Other Than Named Above: Capacity(ies) Claimed by Signer Signer's ❑ Individual ❑ Corporate Officer — Title(s): ❑ Partner — ❑ Limited ❑ Geperal ❑ Attorney -in -Fact ❑ Trustee ❑ Guardian or Conservator ❑ Other: Signer Is Representing: 0 1999 National Notary Association - 9350 Do Soto Ave., P.O. Box 2402 -Chatsworth, CA 91313-2402 - www.nationalnotary.org Prod. No. 5907 Reorder. Call Toll -Free 1.800.876.6527 CALIFORNIA ALL-PURPOSE ACKNOWLEDGMENT State of Californ`eavia- County of SW IC��✓ - as. ;r '1 On )�kyaN 234 14� before me, Date Name and Title of Officer (e.g., -Jane Doe, Not Public') personally appeared Names) of Signer(s) SARAH SAMUEL ' ' 14MWI "�' Corrlrnlssior► • -i Notary RMC - Calton** Santa Olga 1& courhy.- COOM Moff ❑ personally known to me proved to me on the basis of satisfactory' evidence to be the personaay whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/heft& authorized capacity(ija ' and that by his/49~ signature(Won the instrument the person(a), or the entity upon behalf of which the person(s,)' acted, executed the instrument. WITNESS my hand an ficial seal. e of Notary Public OPTIONAL Though the information below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent removal and reattachment of this form to another document. Description of Attached Document )tle or Type of Document: ��U�� //%{ L�y�'f�T /SSP` �� 1A- U5c a �-- i6� � � SB- !e �� 14 n4, ui/L1r r C+ Document Date: _2 g2�/ flS Number of Pages: —� Signer(s) Other Than Named Above: _ Capacity(ies) Claimed by Signer Signer's ❑ Individual \ ❑ Corporate Officer — Title(s): _ ❑ Partner — ❑ Limited ❑ General ❑ Attorney -in -Fact ❑ Trustee ❑ Guardian or Conservator ❑ Other: Signer Is Representing: 0 1999 National Notary Association • 9350 De Solo Ave., P.O. Box 2402 • Chatsworth, CA 91313.2402 • www.naoonalnotary.org Prod. No. 5907 Reorder: Cell Toll -Free 1-600-676-6827 7-7(,'o- 40(06 oj��� Certificate of Occupancy Lraro�7rx�4� .0 .... OF T9�5 Buildin & Safet Department g y This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-697 VIA DONA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-6782 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Ruilding: Michael Ingster Address: 20600 Lomita Avenue City, ST, ZIP: Saratoga, CA 95070 By: Steven Willett ^� Date: April 20, 2006 Building Official POST IN A CONSPICUOUS PLACE _ j Will TITLE 24 REPORT Title 24 Report for: Ingster Residence Lot 35-D, The Hideawa La Quinta, CA 92253 ,, Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA �� Kristi Hanson Architects, Inc. 72-185 Painters Path Suite #A Palm Desert, CA 92260 760-776-4068 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 11/24/2004 D computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. �•;, EnergyPro 3.1 By EnergySoft Job Number. User Number: 5862 50.4)s697 umOnnA ef�l(E�foP4 i� ' TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads Equipment Specifications 1 2 3 6 8 12 14 16 19 23 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5862 Certificate of Compliance: Residential (Pa -t 1 of 2) CF -1 R Ingster Residence 11/24/2004 Project Title Date Lot 35-D. The Hideaway La Quinta Project Address Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,468 ft2 Average Ceiling Height: 12.4 ft Total Conditioned Slab Area: 3,863 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Flocr Number of Dwelling Units: 1.00 Number of Stories: 2 ® Raised Floor Const. Component Frame Assembly Location/Comments TvDe Type U -Value (attic, garage, tyoical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Ihsulation Solid Wood Door Wood 0.387 Exterior Door Between Floors Wood 0.080 Exterior Floor / Over Open Space FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (North) 25.0 0.55 0.45 Bug Screen ❑ K ❑ Q Left (South) 11.0 0.45 0.45 Bug Screen ❑ 191 ❑ 0 Left (South) 46.0 0.55 0.45 Bug Screen ❑ 0 ❑ n Rear (West) 86.8 0.45 0.45 Bug Screen ❑ 0 ❑ 0 Rear (West) 250.0 0.60 0.50 Bug Screen ❑ X❑ ❑ 0 Right (North) 36.0 0.45 0.45 Bug Screen ❑ Q ❑ X❑ Front (East) 144.0 0.60 0.50 Bug Screen ❑ X❑ ❑ Q Front (East) 46.0 0.45 0.45 Bug Screen ❑ X❑ ❑ 0 Front (East) 20.0 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Left (South) 80.0 0.60 0.50 Bug Screen ❑ Q ❑ X❑ ❑ ❑ ❑ ❑ Run Initiation Time: 11/24/0410:37:21 Run Code: 1101321441 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Pa e:3 of 32 0 Certificate of Compliance: Residential (Prart 2 of 2) CF -1 R Ingster Residence 11/24/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 42 Setback Sleeping Areas Central Furnace 80% AFUE Ducts in Attic 42 Setback Living Areas Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 42 Sethack Sleeping Arenc Split Air Conditioner 13.0 SEER Ducts in Attic 42 Sethack I eying Areas WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Temp 1_ 75,000 75_ 0J6 n/a n/a A.O. SMITH FPS -40-224 Small Gas Recirc/Time+Temp 1 42,000 40 032 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's req,iires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Gina Rose Title/Firm: Kristi Hanson Architects, Inc. Title/Firm: G.R. Rose CAD Design Address: 72-185 Painters Path Suite #A Address: 42335 Washington Suite F #330 Palm Desert, CA 92260 Palm Desert, CA 92211 Teleph ne: 0-776-4068 Telephone: (760) 345-4859 Lic. #: (signatu ( te) signature) (da e) Enforce ent Agency Name: Title/Firm: Address: Telephone: 1EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: PageA of 32 1 Certificate of Compliance: Residential (Addendum) CF -1 R Title 11/24/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "Sleeping Areas" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Sleeping Areas" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 472 sgft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 947 sgft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Areas" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Living Areas" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2244 sgft Exposed Slab Floor, 4.00" thick at Zone 2 -Downstairs HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sgft Covered Slab Floor, 4.00" thick at Zone 2-Downmtairs HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R. plan Field he HVAC System "Sleeping Areas" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide erifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Sleeping Areas" is using reduced duct leakage to comply and must have diagnostic site test.ng of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Areas" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Areas" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 11/24/04 10:37:21 Run Code: 11OM321441 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 32 Mandatory Measures Checklist: Residential (Pace 1 of 2) MF -1 R NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance s;pproach used. Items marked with an . asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance- When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(,): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑t§150(c): i( not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent. E] §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. ❑X §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 32 40 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. Alien this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance spec.fications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FV §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5862 Job Number: Page:7 of 32 Computer Method Summary (Part 1 of 3) C -2R gst, Residence 11 /24/2004 rolect Title C is -n The�lideaway La Quinta Date Project Address Beilding Permit # SS_.B_Ro (760) 345-4859 _Se_CADDesign Documentation Author Telephone Plan Check/Date Computer�elformance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.48 4.03 1.45 Space Cooling 46.13 41.39 4.74 Domestic Hot Water 6.38 5.83 0.55 Totals 57.98 51.25 6.73 rd: Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 4,468 ft2 Single Fam Detached (East) 90 deg 1.00 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume 11.6% Floor Construction Type: XX Raised Floor ❑X Slab Floor Total Fenestration Araa: 16.7% Total Conditioned Volume: 55,455 ft 3 Total Conditioned Slab Area: - 3,863 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area RleepingAwas1419 X7,028 -0._32 -Lwin-Areas 3,.0.4.9 38-427 -0-68_ OPAQUE SURFACES Solar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference RooL 0.,41.9 O.D28 0 0 WaU- -29.9 -0059 0 _90_ Wall- 204 _0..059 _9.0 90_ Wall- 667 -W05,9 1 80 90 -Wall _--195 9.0.59 _27-0 90 Root 0..839 0028 0 0_ -Nat X40 0..059 0 90 Wall 6247 0.050 90 90 RnoL 20 0..387 90_ 90_ -Wall- X8.0 0M.9- x.80_ 90_ _Wall- -390 ---0-059- 97090 Roof- 605 0028 0 0. -Walt X87 -0-(159- 0_ 90 -Wall 39.6 0.059 -90--9-0 Mall- 171 _0_059 180 -90- -Wall X6.8_ -0_05.9 -270_ 90 Boor- -6.05 008.0 0_ x_8.0 r R38BooL(B_382xt416) R2LW,�L(w 21_1.6.) &2L1p(a11 (W2�.16.) R -21-W_ IL(18L21. W-1-6) R-21_1Nall MI 21_2x6._1.6) R3.L16.) _R-2LWalL(W.2.12x6.1.6) R-21 Wa1L(W.21-2x6161 _Solid 1 nnri noor R-21 Wall (-W-221 9YR 16.) 2J -V .R_38B0oL(R_38 2xt416a R-21 Wall (W.21 24.16) R- WalL(N21.2x616) R-21_1VLaILpN.21.2x6.16) B21_1NaILpN.21..7YFs .B.eiween_Eloots Sleeping -SleepingStaL 8 n/a Living _LivingSiat- 8 -nta Location / Comments Zone) Zone 1 Zone 1 7-one24.ownstairs 7-One2D.ownstairs Zone2DDWnstalrS 7one2_Downstairs 7-one2D.ownstairs Zone�.olemstairs ZBr1e_2 JpsWrs Zone 2Jpstairs Zone 9- pstairs Zone -2 -- upstairs Zone--Jpstairs Zone -2 -Upstairs EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:8 of 32 1 Computer Method Summary (Part 2 of 3) C -2R j- 2 3 4 5 6 7-- 8 8 .9- J-0 1 12 13. 14 15 16 17 18 19 20 21 22. 23 24 25 26 0 - Area Factor SHGC Act. Azm Tilt Glazing Type 11/24/2004 D ate Location/ Comments Wfl3d.o.w Right (North) -25_0 -0.55.0_ Q 45_ 0 -9.0. Fleetwood Glazing Zone 1 Window Left (South) 3.0 0.450 0.45 180 90 Fleetwood Glazing Zone 1 Window Left (South) 30.0 0.550 0.45 180 90 Fleetwood Glazing Zone 1 Window Left (South) 8.0 0.450 0.45 180 90 Fleetwood Glazing Zone 1 Window Rear (West) 3.0 0.450 0.45 270 90 Fleetwood Glazing Zone 1 Window RearWest 15.0 0.450 0.45 270 90 Fleetwood Glazing Zone 1 Window Rear (Westl 15.0 0,450 0.49 270 -90 Fleetwood Glazing Zone 1 Window Rear (West) 60.0 0.600 0.50 270 90 Fleetwood Glazing Zone 1 Window Right (North) 12.0 0.450 0.45 0 90 Fleetwood Glazing Zone 2 -Downstairs Window Right ( `LIQ 12.0 0.450 0.45 0 90 Fleetwood Glazing Zone 2 -Downstairs Window Right North 12.0 0.450 0.45 0 90 Fleetwood Glazing Zone 2 -Downstairs Window Front (East) 48.0 0.600 0.50 90 90 Fleetwood Glazing Zone 2 -Downstairs WMdoyv Eront (East)_ 48-0 0-600- 5Q 90. -90 Fteetvv_oo f7lazing Zoae_2_Domstairs Window Front (East)_ 6.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Downstairs Window Front (East) 20.0 0.550 0.45 90 90 Fleetwood Glazing Zone 2 -Downstairs Window Left South 80.0 0.600 0.50 180 90 Fleetwood Glazing Zone 2 -Downstairs Window RearWest_ 2.8 0.450 0.45 270 90 Fleetwood Glazing Zone 2 -Downstairs Window Rear (West) 190.0 0.600 0.50 270 90 Fleetwood Glazing Zone 2 -Downstairs Window Rear (West). 45_,9_ 0.450 0.45 270 40 Fleetwood Glazing Zone 2 -Downstairs Window Front (East) 48.0 0.600 0.50 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Front (East) 8.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Front (East) 8.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Front _(East)_ 8.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Front East 8.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Front (East) 8.0 0.450 0.45 90 90 Fleetwood Glazing Zone 2 -Upstairs Window Left (South) 16.0 0.550 0.45 180 90 Fleetwood Glazing Zone 2 -Upstairs Window Rear (West) 8.0 0.450 0.45 270 90 Fleetwood Glazing Zone 2 -Upstairs Window Rear (West) 8.0 0.450 0.45 270 90 Fleetwood Glazing Zone 2 -Upstairs INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bua Screen 0.76 3 Bug Screen 4 Bug Screen 5 Bug Screen 6 Bug Screen 7 Bug Screen 8 Bug Screen 9 Bug Screen 10 Bug Screen 11 Bug Screen 12 Bug Screen 13 Bug Screen 14 15 16 17 18 19 20 21 22 23 24 25 26 27 W Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Pane:9 of 32 1 Computer Method Summary (Part 3 of 3) C -2R 11/24/2004 Date THERMAL MASS FOR HIGH MASS DESIGN Minimum Distribution Type Energy Factl Type (furnace, heat Area Thick. Heat pump, etc.) Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments - crate Heavvweight 472 X0.0 —28. _0_98. n/a Q ZoftelLSJab-o�Grade Concrete. HeamMeight 947 4_00 28 0_98 n/a 2 cone 1 / Slab on Grade Concrete. Heavyweight 2,244 4.00 28 -OM n/a 0 cone 2 -Downstairs / Slab on Grade Concrete, Heavyweight 200 4_00 28 0_98 n/a 2 cone 2 -Downstairs / Slab on Grade PERIMETER LOSSES Slab Perimeter 23 -Slab-I?-e =ler X04. Slab Perimeter 173 HVAC SYSTEMS F2 Insulation Factor R -Val. Dept/ 0 04 0 026 —0-0. —Q 0.76 2Q _Q Location / Comments Zone 2 -Downstairs Heating Equipment Minimum Distribution Type Energy Factl Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Sleeping Areas Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Living Areas Oydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Energy Factl 1 Tank Insul. Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments .Split Air Conditioner 13.0 SEE ts in Attic 4.2 Setback Sleeping Areas Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback Living Areas WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) 'Efficiency Loss (%) Ext. A.O. SMITH FPS -75-230 $ma 1 Gas Recirc/Time+Temp_ 1 75,000 75 0.76 n/a n/a A.O. SMITH FPS -40-224 Small Gas Recirc/Time+Temp 1 42.000 40 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Sta-ldby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 11/24/0410:37:21 Run Code: 1101321441 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 10 of 32 41 Computer Method Summary (Addendum) C -2R Title 11/24/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "Sleeping Areas" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Sleeping Areas" includes credit for a Radiant Barrier installed per Section 8.13 of the Resideltial Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 472 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 947 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Areas" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Living Areas" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2244 sqft Exposed Slab Floor, 4.00" thick at Zone 2 -Downstairs HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Covered Slab Floor, 4.00" thick at Zone 2 -Downstairs HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CECGapproved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "Sleeping Areas" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Sleeping Areas" is using reduced duct leakage to comply and must have diagnostic site tes.ing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Areas" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Areas" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form- EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 11 of 32 1 0 iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE In ster Residence 11/24/2004 YSTEM NAME FLOOR AREA Sleeping Areas 1,419 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensibly Latent CFM I Sensible 1,467 26,542 656 575 21,409 0 1,327 1,070 0 0 0 0 0 0 0 0 0 1,327 1,070 29 136 656 TRANE 4TTX4060/TUD100R960 (5) 41,652 5,602 Total Adjusted System Output 41,652 5,602 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 26.0 of 69.5 of 69.5 of ■ 105.0 of Outside Air 0 cfm Supply Fan Heating Coil 2000 cfm 69.5 of >% Return Air Ducts 'I 23,549 79,000 79,000 Jan 12 am Supply Air Ducts 104.5 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0/73.5OF 72.6/60.5OF 72.6/60.5OF 55.0/53.8OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.6 / 54.0 of 2000 cfm 51.1% R.H. ROOMS 72.6/60.5 of 72.0 / 60.3 of K Return Air Ducts 4 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:12 of 32 JHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE 4 Ingster Residence 11/24/2004 YSTEM NAME FLOOR AREA Living Areas 3.049 26.0 of 69.2 of 69.2 of Outside Air 0 cfm Supply Fan 4000 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblal Latent CFM I Sensible 4,986 90,201 1,408 1,789 66,625 0 4,540 3,331 0 0 0 0 0 0 0 0 0 4,510 3,331 99 � 1,408 73 287 TRANE 4TTX4060/TUD100R960 (5) 84,,-278 10,481 158,000 Total Adjusted System Output ga X78 1o,a81 158,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Heating Coil Supply Air Ducts 104.2 of ROOMS 70.0 of Return Air Ducts `S :OGLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 15.0 / 73.5 of 73.1 / 60.7 of 73.1 / 60.7 of 55.0 / 53.8 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 56.1 / 54.2 of 4000 cfm 51.2% R.H. ROOMS 73.1/60.7 of 72.0 / 60.3 of Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 13 of 32 r IROOM LOAD SUMMARY --71 PROJECT NAME DATE In ster Residence 11/24/2004 YSTEM NAME FLOOR AREA Sleeping Areas 1,419 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 1,467 26,542 656 1,467 2E,542 656 575 21,409 PAGE TOTAL 1 1,467 26,542 656 575 21,409 TOTAL 1 1,467 26,542 656 575 21,409 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 14 of 32 ROOM LOAD SUMMARY PROJECT NAME DATE In ster Residence 11/24/2004 YSTEM NAME FLOOR AREA Living Areas 3,049 Rnnm I nAn St IMMARY PAGE TOTAL TOTAL ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 -Downstairs Zone 2 -Downstairs 1 4,010 72,549 1,129 4,010 72549 1,129 1,482 55,203 Zone 2 -Upstairs Zone 2 -Upstairs 1 976 17,652 280 976 17'652 2801 307 11,421 PAGE TOTAL TOTAL 1 4,986 90,201 1,408 F 1,786 66,625 1 4,986 90,201 1,408 1,789 66,625 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 15 of 32 77771 ROOM HEATING PEAK LOADS Project Title Date ster Residence 11/24/2004 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 1,419 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 7001 Conduction Area U -Value AT 01= Btu/hr 1419.0 X X X X X X x x x x x x x X X X X X X x x X x x x x x x x x x x x x x x x x x 0.0284 X X X X X X x x x x X x x x x x X K IK x x x x x x x x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,770 1,365.0 0.0592 44.0 3,556 55.0 0.5500 44.0 1,331 44.0 0.4500 44.0 871 60.0 0.6000 44.0 1,584 perimeter = 127.0 44.5 5,652 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 764 Infiltration: I1.00 X 1.064 X 1 419 X 12.00 X 0.50 / 60] X 0 = 6645 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,409 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 16 of 32 ROOM HEATING PEAK LOADS Project Title Date Affillingster Residence 11 /24/2004 Room Information Design Conditions Room Name zone 2 -Downstairs Time of Peak Jan 12 am Floor Area 2,444 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1,839.0 X X X x X X X x x x x x x x x x x x x x x x x x X X x x x x x x x x x x x x x 0.0284 x X X x x X X x x x x x x x x x x If x x x x x :C K X x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = = = = =. = = 2,294 7,963.2 0.0592 44.0 20,746 79.8 0.4500 44.0 1,580 20.0 0.3872 44.0 341 366.0 0.6000 44.0 9,662 20.0 0.5500 44.0 484 perimeter = 173.0 44.5 7,698 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 42,806 Infiltration: II 1.001X 1.064 x 2444 x 13.00 x 0.50 / 60] x 0 = 12 398 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 55,203 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 17 of 32 ROOM HEATING PEAK LOADS AhProject Title Date nester Residence 11/24/2004 Room Information Desicin Conditions Room Name zone 2 -Upstairs Time of Peak Jan 12 am Floor Area 605 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 605.0 X X X X X X X x X X X X x x X x x x x x X X X x x X X X X X X x x x x x x x x 0.0284 X x X X x x X x X X X x x x x x x x x x x x x x x x x ={ K K K x x x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = 755 1222.0 0.0592 44.0 3,184 48.0 0.6000 44.0 1,267 56.0 0.4500 44.0 1,109 16.0 0.5500 44.0 387 605.0 0.0797 44.0 2,123 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 8 824 Infiltration:1 1.00 x 1.064 x soy x 11.00 X 6] x &T = 2 597 chedule Ir Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,421 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 18 of 32 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Ingster Residence 11/24/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction 38 Roof R.38.2x14.16 21 Wall W.21.2x6.16 leetwood Glazing leetwood Glazin Fleetwood Glazing Area U -Value DETD1 61.0 40.6 44.0 44.0 44.0 Zone 1 72°F 116°F 440E Btu/hr 2,454 3,281 1,331 871 1,584 1. Design Equivalent Temperature Difference (DETD) Page Total 9 522 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 1 (North) 16 (South) 15 (South) 14 (South) 13 (West) 12 (West) 11 (West) G (West) 48 ( 0.0 1 30.0 ( 0.0 X x X x X X x x x x 1 + + + + + + + + + + 25.0 X X X X x X X X x x 15 ) X X X X x X X X )x )x 0.50 = = = = = = = = = = 188 ( 0.0 1 3.0 32) 0.50 48 ( 0.0 1 30.0 32) 0.50 481 ( 0.0 1 8.0 32) 0.50 128 ( 0.0 1 3.0 73) 0.50 110 ( 0.0 1 15.0 73) 0.50 549 ( 0.0 1 15.0 73) 0.50 549 ( 0.0 1 60.0 73) 0.557 2,438 ( ( Sched. Page Total 4 490 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,419 X 0.500 Watts/sgft xA3.413BtuhfWatt Btuh/Watt = 2,422 Occupants 1.00 X 1,419 X 245 Btuh/OCC. / sgft/occ. = 1,043 Receptacle 1.00 x 1,419 x 0.500 Watts/sgft X - 2,422 Process 1.00 x 1,414 x 91x9 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Infiltration: Q0 x Air s �m x A 1Ceiling Height x / 60] _ E=V�A� Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,5421 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 419 x 155 Btuh/OCC. / 333 sgft/occ. = 660 Receptacle 1.00 X 1 419 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 X 1 419 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: 1.00 x 4 77 x 1 41 x 12.00 x 60] -0.00001 = 0 chedule Air Latent Area Ceiling Height ACH n1yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 656 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 19 of 32 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Ingster Residence 11/24/2004 Project Title Date Room Name Zone 2 -Downstairs Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 1160F Design Temperature Difference: 440F Conduction 38 Roof R.38.2x14.16 21 Wall W.21.24.16) leetwood Glazin Solid Wood Door leetwood Glazing leetwood Glazing Area U -Value 0.0284 0.0592 X X X X X X DETD 1 = = = = = = Btu/hr 61.0 3,181 40.6 19,143 44.0 1,580 40.6 314 44.0 9 662 44.0 484 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 34,364 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 5 North (North) 3 (North) C B (East) (East) 2 (East) 17 (East) E (South) 28 (West) F West ( 0.0 X X x x X x xA111 x X 1 + + + + + + + 12.0 X X X X X X x x X 15)X X X x X x X x 0.50 = = = = = = = = = = 90 ( 0.0 15+ 12.0 15) 0.50 90 ( 0.0 1 12.0 15)X 0.50 90 ( 0.0 14,+ 48.0 73) 0.557 1,950 ( 0.0 151+ 48.0 73) 0.557 1,950 ( 0.0 6.0 73) 0.50 219 ( 0.0 20.0 73) 0.50 731 ( 0.0 15 80.0 32) 0.557 1,425 ( 0.0x:A111 2.8X 7)x 0.50 102 ( 0.0 1 190.0 73) 0.557 7,720 Sched. Page Total 14 370 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,444 x 0.500 Watts/sgft X 3.41 Btuh/Watt = 4,171 Occupants 1.00 X 2,444 X 245 Btuh/OCC. / 333 sgft/occ. = 1,796 Receptacle 1.00 x 2,444 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 4,171 Process 1.00 x 2,444 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Infiltration: 00 x1.o5a x x x 0.50 / 60] Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,549 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2444 x 155 Btuh/occ. / 333 sgft/occ. = 1 136 Receptacle 1.00 x 2444 x 0.000 Watts/sqft X 1 3.41 Btuh/Watt = 0 Process 1.00 x 2444 x 0.000 Watts/sqft x 1 3.413 Btuh/Watt = 0 Infiltration: I tool X L 4,77 X 2444 X 13.00 x 0.50 / 60] 0.00001 = chedule AIr Latent Area Ceiling Height ACH DW • Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,129 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:20 of 32 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Inaster Residence 11/24/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 2 -Downstairs 720F 116°F 44°F Conduction Area U -Value DETD' Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 10 est) 0.0 X 1 + 35.0 x 73)X 0.50 = 1,280 x + X )X x + x )x x + x )x = X + x )x x + X )X x + X )x X + X )x X t X )X = Sched. Page Total 1 280 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 2,444 X 0.500 Watts/sgft x 3.4 Btuh/Watt = 4,171 Occupants 1.00 X 2,444 X 245 Btuh/occ. / 323 sgft/occ. = 1,796 Receptacle 1.00 x 2,444 X 0.500 Watts/sgft x 3.4-3 Btuh/Watt = 4,171 Process 1.00 x 2,444 x 0.000 Watts/sgft x 3.4' 3 Btuh/Watt = 0 Infiltration: Qp x 1.osa x 2,444 x Oo x / 60] = 12s$ Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,5491 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2444 x 155 Btuh/OCC. sgft/occ. = 1 136 Receptacle 1.00 x 2444 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0' Process j� 1.00 x 2444 x 0.000 Watts/sgft Btuh/Watt = 0 Infiltration: I 1.0o x a 77 x 2444 x 13.0o x o.50 / 60] -m000l = �8 —Schedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,129 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:21 of 32 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Ingster Residence 11/24/2004 Project Title Date Room Name Zone 2 -Upstairs Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 116 0F Design Temperature Difference: 440F Conduction 2x14.1 Area U -Value 605.1 X 1 0.02841 X X X X X X DETD 1 = = = = = = Btu/hr 61.0 1,046 40.6 2,938 44.0 1,267 44.0 1,109 44.0 387 32.0 1.544 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 8,291 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr AP (East) 29 (East) 30 (East) 31 32 33 (East) (East) (East) 28 South 26 (West) 27 (West) 73 0.50 ( 0.0 X X X x X x x x x x 15 + + + + + + + + + 48.0 X X X X X X X x X x 73 ) X ) x X x X X x X x )XI 0.557 = = = = = = = = _ = 1,950 ( 0.0 151+ 8.0 73 0.50 293 ( 0.0 1 8.0 73) 0.50 293 ( 0.0 1 8.0 73) 0.50 293 ( 0.0 15 8.0 73) 0.50 293 ( 0.0 1 8.0 73) 0.50 293 ( 0.0 1 16.0 32) 0.50 256 ( 0.0 1 8.0 73) 0.50 293 ( 0.0 15 8.0 7) 0.50 293 ( I I Sched. Page Total 4 255 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 605 x 0.500 Watts/sgft X 3.413 Btuh/Watt = 1,032 Occupants 1.00 X 605 x 245 Btuh/OCC. / 333 sgft/occ. = 445 Receptacle 1.00 x 605 x 0.500 Watts/sgft X 3.413 Btuh/VVatt = 1,032 Process 1.00 X 605 x 0.000 Watts/sgft X 3.413 BtuhfWatt = 0 Infiltration: ��n d o� x Air Sensible x Area Ceiling x calling Height o x 60] ACH 5 / _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,652 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 605 x 155 Btuh/occ. / 333 sgft/occ. = 281 Receptacle 1.00 x 605 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 X 605 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 1.00 X 4 77 X 60 X 11.00 X 60] 0.00001 = 0 chedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 280 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:22 of 32 TITLE 24 REPORT Title 24 Report for: Ingster Residence -Guest House Lot 35-D, The Hideaway La Quinta, CA 92253 Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path Suite #A Palm Desert, CA 92260 760-776-4068 • Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 10/26/2004 EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is eue thorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Buitling Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5862 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 Room Heating Peak Loads 14 Room Cooling Peak Loads 15 Equipment Specifications 16 EnergyPro 3.1 By EnergySoR Job Number: User Number: 5862 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Ingster Residence -Guest House 10/26/2004 • Protect Title Date Lot 35-D, The Hideaway La Quinta Project Address Bu Iding Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only • n u GENERAL INFORMATION Total Conditioned Floor Area: 615 ft2 Total Conditioned Slab Area: 615 ft2 Building Type: (check one or more) Average Ceiling Height: 11.0 ft X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Fcoor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Hnsulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (North) 40.0 0.45 0.45 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 37.5 0.55 0.45 Bug Screen ❑ x❑ ❑ X❑ Front (West) 48.0 0.60 0.50 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ 1:1 El ❑❑ 1:1 1:1 1:1 F1 1:1 El 1:1 El El El El El Run Initiation Time: 10/26/04 09:32:21 Run Code: 1098808341 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Pa e:3 of 25 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has oeen signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Kristi Hanson Architects, Inc. Address: 72-185 Painters Path Suite #A Palm Deserl, CA 92260 Telephone: 760- o Lic. #: (signature) (date Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Certificate of Compliance: Residential (Part 2 of 2) CF -1 R G.R. Rose CAD Design Ingster Residence -Guest House Project Title 42335 Washingtor Suite F #330 10/26/2004 Date Palm Desert. CA 62211 HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Cesign Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat !Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnnre 80% AFUE Ducts in Attic 42 Setback Guest House Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Setback Guest House WATER HEATING SYSTEMS Rated 1 Tank Energy Facti 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A O. SMITH FPS -40-224 Small Gas Recirclrime+Temp 1- 40 000 40 032 n/a n/a • 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency an i Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has oeen signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Kristi Hanson Architects, Inc. Address: 72-185 Painters Path Suite #A Palm Deserl, CA 92260 Telephone: 760- o Lic. #: (signature) (date Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Gina Rose Title/Firm: G.R. Rose CAD Design Address: 42335 Washingtor Suite F #330 Palm Desert. CA 62211 Telephone: 760 345-4859 �� Z4 4tl (slature) (date) IEnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:4 of 25 1 Certificate of Compliance: Residential (Acdendum) CF -1 R JJnqster Residence -Guest House 10/26/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These iL-ms require special written justification and documentation, and special verification to be used with the performance approach The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "Guest House" must meet all CEC Criteria for a Zonally Controlled system serving only Sleepiag Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 359 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 256 sqft Covered Slab Floor, 4.00" thick at Zone 1 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC•approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 10/26/04 09:32:21 Run Code: 1098808341 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 25 • • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance a 3proach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures 1150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. w Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X§150(c): not apply to exterior mass walls). §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. LX ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA orACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. VI §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 25 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an • asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. W,en this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools o- spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. RI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greatec for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy :)f 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5862 Job Number: Page:7 of 25 r Computer Method Summary (Part 1 of 3) C -2R ste.r_Re.s.idence-G.ue.st_H.ou.se 61.5 0.028_ 0- 10/26/_2rotectTitle On 4.0.0_ _0...0.59_ 0_ Date ot_3-s-D, The_Hid.e.away La_Qui.nta _0..0.59_ 9.0_ Bu Iding Permit # Project Address _EZ2.1_Wall_(W.21..2x6.1-6.) 0..059 18090 G Wall_ 1-61. (760) 345-4859 _27_0 _R.._Ro_se_CAD_Design Documentation Author Telephone Plan Check/Date Computee-man e 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.16 7.87 -2.72 Space Cooling 59.67 47.72 11.95 Domestic Hot Water 31.47 24.84 6.63 Totals 96.29 80.43 15.86 16.5% Total Conditioned Floor Area: 615 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 20.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 6,765 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 615 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Gvest-House 615 _6,.7.65 —J_0.0_ Sleeping _S.leepingS.tat_ 2 —n/.a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt _Roof 61.5 0.028_ 0- —0- 0_Wall— -Wall- 4.0.0_ _0...0.59_ 0_ 9.0_ Wall— 72 _0..0.59_ 9.0_ 9.0_ Wall_4_40 _EZ2.1_Wall_(W.21..2x6.1-6.) 0..059 18090 Wall_ 1-61. 0 059 _27_0 90 • Solar Gains Y / N Form 3 Reference ❑ _B_38_R— 0-0QR..38..2xx1_4..16) ❑ _R2.1_Wa1l_(W.21.2x6._t6.) ❑ R2.1_Wall_(W.2_t.2x6.._1.6.) ❑ .R21_Wall_(W.21-.2x1i16) X 0 _EZ2.1_Wall_(W.21..2x6.1-6.) Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:8 of 25 1 Computer Method Summary (Fart 2 of 3) C -2R Project Residence -Guest House 10/26/2004 Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J_ Windnv—Left(Nortb) 10_0_ —0-450- 0..4.5_ 0_ _90. FleetwoodGlazing -Zone—1 2 Window Left (North. 10.0 0.450 0.45 0 90 Fleetwood Glazing Zone 1 3 Window Left (North). 10.0 0.450 0.45 0 90 Fleetwood Glazing Zone 1 4 Window Left North). 10.0 0.450 0.45 0 90 Fleetwood Glazing Zone 1 5 Window Rear —(East- 37.5 0.550 0.45 90 90 Fleetwood Glazing Zone 1 6 Window Front (West)_ 48.0 0.600 0.50 270 90 Fleetwood Glazing Zone 1 INTERIOR AND EXTERIOR SHADING window Overhang LF#t Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. _en. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 Run Initiation Time: 10/26/04 09.32.21 Run Code: 10988841 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:9 of 25 Computer Method Summary (Part 3 of 3) C -2R ngster r project Title dence-Guest House THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (sf) (in.) Cap. -C9sc-re-t% Heavyw_ejght _3.5.9 -4-00 _28. Concrete. Heavyweight 256 4_00 28 PERIMETER LOSSES 10/26/2004 Date Inside Location Cond. Form 3 Reference R -Val. Comments _0..9.8. Na 0_ Z..,ne_1_1-Slab_onGrade 0_98 n/a 2 Zone 1 / Slab on Grade F2 Insulation h Factor R -Val. Depth Location / Comments Slab—P-e-nmeter 49 -9 76 00 Q Sl.ab_Eebmet er 49 01-6. 0.0 0 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 8019 AFIE D i-cts in A tic 4.2�gthsnsk G�es�4u_ e Oydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Minimum Duct Efficiency Location Duct Thermostat (SEER) (attic, etc) R -Value Type Location / Comments SpR —mlit9ner 14.0 SEER Duuct. in Attic 4.2 SPtback GuW HQu�e WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/hr (gam Efficiency Loss (%) Ext. A.O. SMITH FPS -40-224 Small 3as Reci_rc/Time+Temp 1_ 44999 40 0_62 /a_ n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list emergy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 10/26/04 09:32:21 Run Code: 1098808341 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: -Pa ge:10 of 25 Computer Method Summary (Addendum) 2-2R Title 10/26/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that ctherwise complies 3ased on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "Guest House" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 359 sgft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 256 sgft Covered Slab Floor, 4.00" thick at Zone 1 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field I EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:11 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Ingster Residence -Guest House 10/26/2004 •YSTEM NAME FLOOR AREA Guest House 615 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 866 15,6e2 284 394 14,679 at Time of Cooling 0 115.0/73.5 of 72.6/60.5 of 72.6/60.5 of 763 734 0 0 0 0 0 0 0 0 0 :83 734 17.228 284 TRANE 4TTX4036/TUD100R936 (3) 26,215 3,086 Total Adjusted System Output; 215 3,086 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 51,000 51,000 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 of 69.4 of 69.4 of Outside Air 0 cfm 69.4 of 105.0 of Supply Fan Heating Coil 1200 cfm Supply Air Ducts 104.4 of ROOMS 70.0 of EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 12 of 25 Return Air Ducts S COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 115.0/73.5 of 72.6/60.5 of 72.6/60.5 of 55.0/53.7 of Supply Air Ducts O Outside Air 0 cfm Supply Fan Cooling Coil 55.6 / 54.0 of 1200 cfm ROOMS 50.9% R.H. of 72.0 ! 60.3 of 72.6/60.5 I big Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 12 of 25 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 13 of 25 PROJECT NAME In ster Residence -Guest House DATE 10/26/2004 YSTEM NAME Guest House FLOOR AREA 615 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOL'NG PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Zone 1 Zone 1 1 866 15,662 284 866 15,662 284 394 14,679 PAGE TOTAL 1 836 15,662 284 394 14,679 TOTAL I �i6 15,662 28411 394 14,679 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 13 of 25 ROOM HEATING PEAK LOADS Project Title Date _gster Residence -Guest House 10/26/2004 Room Information Desicin Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 615 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr 615.0 1,172.5 40.0 37.5 48.0 perimeter = 118.0 X x X x x X 44.0 = = = = = = 767 44.0 3,055 44.0 792 44.0 908 44.0 1,267 44.5 5,251 X X Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 12 040 Infiltration: [ 1.001 X 1.064 X 615 X 11.00 X E0] x 44 = 2 640 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,679 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 14 of 25 • RESIDENTIAL ROOM COOLING LOAD SUMMARY ingster Residence -Guest House 10/26/2004 Project Title Date Room Name Zone 1 Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 116 0F Design Temperature Difference: 440F Conduction R-38 Roof (R.38.2x14.16) R-2 W II (W.21.24.16) FIei d Glazing leetwood Glazin Fleetwood Glazin Area U -Value 615rJ. 1.172.5 X 1 0.02841 X X x X X X x :{ DETD 1 = = = = = = = _ Btu/hr 61.0 1,064 40.6 2,819 44.0 792 44.0 908 44.0 1,267 15)x 0.501= 75 ( 0.0 15 10.0 15) 0.50 1. Design Equivalent Temperature Difference (DETD) Page Total 6 849 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area -SGF SC Btu/hr 22 _(North 23 North 24 _(No Lh 25 _ North 21 (East) M (West) 15+ 10.0 15)x 0.501= 75 ( 0.0 15 10.0 ( 0.0 X X x x X X x x X X 15 + + + + + + + + + 10.0 x x x X X X X X X X 15) X X X x x )x )X )X )X 0.501 = = = = = = = 75 ( 0.0 15+ 10.0 15)x 0.501= 75 ( 0.0 15 10.0 15) 0.50 75 ( 0.0 15 10.0 15) 0.50 75 ( 0.0 15 37.5 73) 0.50 1,371 ( 0.0 15 48.0 73) 0.557 1,950 ( ( ( ( Sched. Page Total 3 622 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 615 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,049 Occupants 1.00 X 615 X 245 Btuh/OCC. / 333 sgft/OCc. = 452 Receptacle 1.00 x 615 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,049 Process 1.00 x 615 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: 00 x E x615 x 00 x0=50 / 60] _,640 schedule Air Sensible Area Ceiling Height ACH 4T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,6621 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 615 x 155 Btuh/OCC. / 333 sgft/occ.= 286 Receptacle 1.00 x 615 x 0.000 Watts/sgft X 1 3.413 Btuh/Waft = 0 Process ( 1.00 x 615 x 0.000 Watts/sgft x 1 3.413 Btuh/Watt = 0 Infiltration: I 1.00 x 4 77 x 615 x 11.00 x 0.50 / 6a] 1 -0.00001 = 02 -Schedule Air Latent Area Ceiling Height ACH pyy • Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 284 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 15 of 25 rRAMETM Project Name Equipment Number Sales Office/Distributor Upflow/ Horizontal Gas Furnace" Fan -Assisted 5,8.. Combustion" 21" 19-3/4 \� TUD10OR960K 5/8" -5/8" 28-3/8" 5/8" 1/2 DIA. HOLES ELECTRICAL 13-1/1 CONNECTION f / 4-1/16" 3/4 3-15/16" ` 8-1/4" • 3/4" 28 1/4" 3/4" � ` 22-1 /2" 23-1(2" 3-13/16" l� u 4" DIAMETER FLUE CONNECT 1/2" DO�DO� i 0000 � f DDDD 2-1/16" D D 40" 3-3/4" I 2 1/16" I `)` I 28-1/4" 1 5-5/16" 1-1/2" DIA. HOLE 3/g" GAS CONNECTION 2-1/8" 7/8" DIA. K.O. — ELECTRICAL CONNECTION (ALTERNATE) 1-1/2" DIA. K.O. GAS CONNECTION (ALTERNATE) FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD10OR960K 4 -HIGH -Black 2201 2146 2077 2026 1948 1882 1810 1738 1625 3 - MED. -HIGH - Blue 1943 1909 1857 1804 1786 1716 1659 1579 1506 2 - MED. -LOW - Yellow 1543 1520 1509 1490 1481 1460 1398 1356 1303 1- LOW -Red 1282 1272 1267 1268 1256 1226 1176 1163 1102 CFM VS. TEMPERATURE RISE CFM CUBIC FEET PER MINUTE MODEL 1200 1300 1400 1 1500 1 1600 1 1700 1 1800 1900 1 2000 2100 1 2200 1 2300 2400 TUD10OR960K 62 57 1 53 1 49 1 46 1 44 1 41 39 1 37 35 1 34 1 32 1 31 ©American Standard Inc. 2002 0 General Data o TYPE Upf low / Horizontal RATINGS 2 1 st Stage Input BTUH 65,000 1 st Stage Capacity BTUH (ICS) 3 52,000 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH (ICS) 3 80,000 Temp. rise (Min. -Max.) °F. 30-60 BLOWER DRIVE DIRECT Diameter -Width (In.) 11 x 10 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Performance Motor HP 1/2 R.P.M. 1075 Volts/Ph/Hz 115/1/60 COMBUSTION FAN -Type Centrifugal Drive - No. Speeds Direct - 2 Motor HP - RPM 1/50-3000 Volts/Ph/Hz 115/1/60 F.L. Amps 0.93 FILTER — Furnished? Yes Type Recommended High Velocity Hi Vel. (No.-Size-Thk.) Shipped 1 - 20x25 - 1 in. VENT COLLAR — Size (in.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 5-45 L.P. Gas Qty. — Drill Size 5-56 GAS VALVE Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS—Type Multiport Inshot Number 5 POWER CONN. — V/Ph/Hz 0 115/1/60 Ampacity (In Amps) 12.8 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (In.) 41-3/4 x 23 x 30-1/2 Uncrated (In.) 40 x 21 x 28 WEIGHT Shipping (Lbs.) / Net (Lbs) 162/151 O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. OO Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% br each 1000 feet above sea level. OO Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local odes. Mechanical Specifications NATURAL GAS MODELS—Central heat- ising furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING—Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature - Printed in U.S.A. American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL— Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY—The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for Strength and beauty. The heat exchanges section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces enploy a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem contol lights the main burners upon a demand, for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. 'lent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design withow notice. TRAMETM Project Name Equipment Number Sales Office/Distributor �5/8"� 1 -5/8" 28 3/ 1/2 7/8" DIA. HOLES ELECTRICAL CONNECTION 4-1/16" 3/4 3-15/16" \ \ � \ 8-1/4" 16" 0 • ` 3/4" 28-1/4" 3/4" � ` 22-1/2" 23-1 2" 3-13/16" Upflow/ Horizontal Gas Furnace" Fan -Assisted Combustion" TUD080R936K 4" DIAMETER FLUE CONNECT `)` I 28-1/4" F1 5-5/16" 1-1/2" DIA. HOLE GAS CONNECTION 2-1/8" FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) 1/2" SPEED TAP 0.10 0.20 0.30 1 0.40 1 0.60 0.70 2-1/16" DIA. K.O. TUD080R936K 4 - HIGH - Black ELECTRICAL EL Q Q 1364 CONNECTION 1296 40" (ALTERNATE) 0 3-3/4" 3 - MED. -HIGH - Blue 1-1/2" DIA. 1209 1198 1177 K.O. GAS 1107 1058 999 CONNECTION 2-1/16" I 2 - MED. -LOW - Yellow 1046 (ALTERNATE) `)` I 28-1/4" F1 5-5/16" 1-1/2" DIA. HOLE GAS CONNECTION 2-1/8" FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 1 0.40 0.50 0.60 0.70 0.80 0.90 TUD080R936K 4 - HIGH - Black 1392 1384 1364 1335 1296 1247 1189 1120 1042 3 - MED. -HIGH - Blue 1210 1209 1198 1177 1147 1107 1058 999 930 2 - MED. -LOW - Yellow 1046 1052 1047 1033 1008 973 928 873 808 1 - LOW -Red 900 903 895 888 869 842 808 766 717 CFM VS. TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 1000 1 1100 1 1200 1 1300 1 1400 TUD080R936K 59 1 54 1 49 1 46 1 42 ©American Standard Inc. 2002 General Data o •TYPE Upf low / Horizontal RATINGS 2 1 st Stage Input BTUH 52,000 1 st Stage Capacity BTUH (ICS) 3 41,600 2nd Stage Input BTUH 80,000 2nd Stage Capacity BTUH (ICS) 3 63,000 Temp. rise (Min. -Max.) °F. 30-60 BLOWER DRIVE DIRECT Diameter -Width (In.) 10 x 7 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Performance Motor HP 1/3 R.P.M. 1075 Volts/Ph/Hz 115/1/60 COMBUSTION FAN -Type Centrifugal Drive - No. Speeds Direct - 2 Motor HP - RPM 1/50-3000 Volts/Ph/Hz 115/1/60 F.L. Amps 1.0 FILTER — Furnished? Yes Type Recommended High Velocity Hi Vel. (No.-Size-Thk.) Shipped 1 - 17x25 - 1 in. VENT COLLAR — Size (in.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 4-45 L.P. Gas Qty. — Drill Size 4-56 GAS VALVE Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS — Type Multiport Inshot Number 4 POWER CONN. — V/Ph/Hz < 115/1/60 Ampacity (In Amps) 10.4 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (In.) 41-3/4 x 19-1/2 x 30-1/2 Uncrated (In.) 40 x 17-1/2 x 28 WEIGHT Shipping (Lbs.) / Net (Lbs) 142/132 O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. O Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% tr each 1000 feet above sea level. O Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local Bodes. Mechanical Specifications NATURAL GAS MODELS—Central heat- ising furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING—Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature - Printed in U.S.A. •American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL— Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY—The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in tha cabinet with baked -on enamel finish for Strength and beauty. The heat exchanger section of the cabinet is com- pletely lin3d with foil -faced fiberglass insu- lation. T -tis results in quiet and efficient operation due to the excellent acoustical and insuating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, whch eliminates the waste of a con- stantly turning pilot. The integrated sys- tem cortrol lights the main burners upon a demand for heat from the room thermo- stat. CSmplete front service access. a. Low energy power venter. b. Vent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design withcjt notice. rAME® Project Name Equipment Number Sales Office/Distributor Date 4TTX4060-SUB-100.00 M • NOTE: All dimensions are in mm/inches. ELECTRICAL AND RURIGERANI COMPONENT CLEARANCES PER PREVAILING CODES. LIDUID UNE SERV VALVE, -E I.D TEN. A" C WITH SAC S PRESSURE EAP rITTINI UNITS HOULD BE PLACED SO ROOT RUN -Orf WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 111'1 THOU WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. 01 HER IWO SIDES UNRESTRICTED. MODELS BASE A B C I D I E I F G H I J 4TTX4060A 1 4 1267 946 870 7/8 3/8 152 98 219 86 (49-7/8) (37.1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) From Dwg.21D152635 Rev.3 0 2002 American Standard Inc. All Rights Reserved 5 Ton Sprit System Cooling —1 Phase 4TTX4060A Outdoor Unif o0 4TTX406OA1000A General Data SOUND RATING (CECIBELS) OO 0 78/78 POWER CONNS. — V/PH/HZ 0 208/230/1/60 MIN. BRCH. CIR. AMPACITY 39 BR. CIR. l MAX. (AMPS) 60 PROT. RTG. f MIM. (AMPS) 60 COMPRESSOR CLIMATUFF0 - SCROLL NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS O - L.9. AMPS 30.1 -158 FACTORY INSTALLED START COMPGNENTS OB YES INSULATION/SIDUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN — TYPE PROPELLER DIA. (IN.) - NO. USED 27.6 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN. VY.G. O 4400 NO. MOTORS - HP. 1 -1/6 MOTOR SPEED tR.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.4 OUTDOOR COIR_ — TYPE SPINE FINTAB ROWS-F.P.I. 2-24 FACE AREA (SO. FT.) 26.32 TUBE SIZE (IN-) 5/16 REFRIGERAN'E R-41 OA (O.D. UNIT) NP CHRG. 0 8/04-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN, O.D. GAS 0 7/8 LINE SIZE - In O.D. LIQ. © 3/8 FCCV RESTRICTOR ORIFICE SIZE 0.086 DIMENSIONS H X W X D OUTDOOR UMIT CRATED (IN.) 54 X 35.1 X 38.7 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LBS.) 360 NET (LBS.) 312 NOTES: O CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. O RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. O CRATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD FIR - DRY COIL - OUTDOOR O THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATEAND SERVICE INSTRUCTION. O MAX. LINEAF LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 32,3312-01. O THE VALUE SHOWN FOR COMPRESSOR ALA ON THE UNIT NAMEPLATE AND ON TH S SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH C RCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS -HE BRANCH CIRCUIT SELECTION CURRENT. O NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONEATS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. O RATED IN .CCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 4TTX4060A With Cooling Coils 4TEE3F49A 4TEE3F65A 4TEP3F42A 4TEP3F48A 4TEP3F63A TWE04204 TWE048C14 TYPE RXA061S3 RXC054S3 RXC060S3 RXC061S3 RXC065S3 RXH063S3 •RXA060S3 EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 62500 63000 58500 60500 63000 58000 BTUH (TOTAL) 59500 60500 59500 59500 60500 61500 63500 BTUH (SENSIBLE) 41700 43600 41800 41700 43600 46100 48000 INDOOR AIRFLOW (CFM) 1700 1800 1700 1700 1800 2000 2000 SYSTEM POWER (KW) 5.83 5.87 5.83 5.83 5.87 5.94 6.02 EER / SEER (BTUANATT--HR.) 10.20/12.25 10.30/12.50 10.20/12.25 10.20/12.25 10.30/12.50 '10.35/12.50 10.55/12.75 O Certified in accordance with A.R.I. Standard 210/240. TXA042C4 TXA043C4 TXA048C4 TXA049C4 TXA050C4 TXC042C4 TXC043C4 EXPANSION TYPE CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 RATINGS (COOLING) O BTUH (TOTAL) 54500 58500 57000 60000 60000 54500 58500 BTUH (SENSIBLE) 35200 40300 37700 42000 42000 35200 40300 INDOOR AIRFLOW (CFM) 1200 1575 1350 1675 1675 1200 1575 SYSTEM POWER (KW) 5.53 5.85 5.67 5.94 5.94 5.53 5.85 EER / SEER (BTU/WATT-HR.) 9.85/11.25 10.00/11.50 10.05/11.50 10.10/11.50 10.10/11.50 9.85/11.25 10.00/11.50 TXC048C4 TXC049C4 TXC050C4 TXH041A4 TXH054A4 EXPANSION TYPE CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 RATINGS (COOLING) O BTUH (TOTAL) 57000 60000 60000 59500 62500 BTUH (SENSIBLE) 37700 42000 42000 41300 44700 INDOOR AIRFLOW (CFM) 1350 1675 1675 1575 1700 SYSTEM POWER (KW) 5.67 5.94 5.94 5.86 6.04 EER / SEER (BTU/WATT-HR.) 10.05111.50 10.10/11.50 10.10/11.50 10.15/11.50 10.35/11.75 4TTX4060A With Air Handlers • 4TTX4060-SUB-100.00 4TEE3F49A 4TEE3F65A 4TEP3F42A 4TEP3F48A 4TEP3F63A TWE04204 TWE048C14 TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB CHG TO 86 CHG TO 86 •EXPANSION RATINGS (COOLING) O BTUH (TOTAL) 62500 63000 58500 60500 63000 58000 60500 BTUH (SENSIBLE) 45400 45700 40500 43600 47400 40400 43800 INDOOR AIRFLOW (CFM) 1800 1800 1575 1800 2000 1575 1800 SYSTEM POWER (KW) 5.95 5.83 5.79 5.87 6.24 5.89 6.08 EER / SEER (BTUANATTHR.) 10.50112.50 10.80/13.00 10.10112.00 10.30/12.25 10.10/12.00 9.85/11.50 9.95/11.50 Notes: O Certified in accordance with A.R.I. Standard 210/240. • 4TTX4060-SUB-100.00 4TTX4060A With Furnaces & Coils TUO140R9 • +RXC065S3 EXPANSION TYPE TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 59000 BTUH (SENSIBLE) 40800 INDOOR AIRFLOW (CFM) 1575 SYSTEM POWER (KW) 5.78 EER 1 SEER (BTUANATT--HR.) 10.20112.45 Notes: O Certified in accordance with A.R.I. Standard 210/240. • 4TTX4060-SUB-100.00 • • Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 DuratuffTm Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The ClimatufP compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff® compressor is standard with a 10 year limited warranty. O�,pED TO4q jWP % C e 3'' l F - 9 � It 9�JS14'DA PDM10 as TRMIE' Condenser :oil The Spine FinTM coil shall be continuously wrapped, co rosion resistant all alumi- num with mi iimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a oantinuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure rper square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro- tected on all four sides by louvered panels and! has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability -o 55D17. The addition of an evaporato defrost control permits operation to 40DF. The addition of an evaporatcr defrost control with TXV permits !cw ambient cooling to 30DF. Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -bas -3 to match thermostat and locking t;nermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemental heat ou_door ambient lockout from 46 to -- ODF. Trane A business of American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trane.com design and specifications without notice. TRAWE® Project Name Equipment Number Sales Office/Distributor 4TTX4036.-S U B-100.00 • C7 NOTE: All dimensions are in mm/inches. 61Cw4MZ"to ELECTRICAL AND REFRIGERANT COMPONENT CLCARANC ES PER PREVAILING CODES. LIOUID LINE SCAM VALVE, B'B' ZE COI,D EENNCtiMI RAI WITH IYA• SAE FLI PRESSURE IAP FITTIN( UNITSHOULD BE PLACED SO ROOF RUNOFF WAY CR DOES NOT POUR DIRECTLY ON UNIT. AND SHOULD BE AT LEAST 305 IIZ'I FROM WALL AND ALL SURROUNDING SHRUBBERY ON I'x0 SIDES. OTHER TWO SIDES UNRESTRICTED. MODELS BASE A B C I D I E I F G H J 4TTX4036A 3 1118 829 756 3/4 3/8 143 92 210 79 44 32-5/8 29-3/4 5-5/8)l (3-5/8)l8-1/4 3-1/8 From Dwg. 21D152635 Rev. 3 0 2002 American Standard Inc. All Rights Reserved 3 Ton Split System Cooling —1 Phase 4TTX4036A Outdoor Unit o0 4TTX4036A1000A General DatE. SOUND RATING (CECIBELS) (D 0 74/72 POWER CONNS. — V/PH/HZ O 208/230/1/60 MIN. BRCH. CIR. A%IPACITY 21 BR. CIR.l MAX (AMPS) 35 PROT. RTG. } Mlh-. (AMPS) 30 COMPRESSOR CLIMATUFF® - SCROLL NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 208/230/11/60 R.L. AMPS O - L.R. AMPS 15.4-83 FACTORY INSTAL' _ED START COMPONENTS OO NO INSULATION/SOUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN — TYPE PROPELLER DIA. (IN.) - NO. USED 23 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN.1ILG. O 3100 NO. MOTORS - FP. 1 -1/6 MOTOR SPEED Q.P.M. 825 VOLTS/PH/HZ 200/230/11/60 F.L. AMPS 1.4 OUTDOOR COIL — TYPE SPINE FIN TM ROWS - F.P.I. 1 -24 FACE AREA (SC. FT.) 21.20 TUBE SIZE (IN.) 5/16 REFRIGERANT R-41 OA (O.D. UNIT) NP :,-HRG. © 5/11-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 3/4 LINE SIZE - IN.. O.D. LIQ. © 3/8 FCCV RESTRICTOR ORIFICE SIZE 0.065 DIMENSIONS H X W X D OUTDOOR UNIT CRATED (IN.) 48.3 X 30.1 X 33.8 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LIS.) 255 NET (LBS.) 219 NOTES: O CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT ZERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. CJ RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. O CALCULATED`NACCORDANCEWITHNATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIA - DRY COIL - OUTDOOR OO THIS VALUE PPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. © MAX. LINEAR _ENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCR DLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 324.312-01. 0' THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. 0 NO MEANS JO START COMPONENTSYES MEANS QUICK START KIT COMPONENJS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. OO RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 4TTX4036A With Cooling Coils RXC036S3 RXC037S3 RXC054S3 TXA030C4 7=31C4 TXA035C4 •RXC031S3 EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 35200 36400 36400 36800 34600 35000 34600 BTUH (SENSIBLE) 26100 27700 27700 29000 25300 25700 25300 INDOOR AIRFLOW (CFM) 1110 1200 1200 1350 1100 1100 1100 SYSTEM POWER (KW) 3.20 3.26 3.26 3.32 3.22 3.24 3.22 EER / SEER (BTU/WATT--HR.) 11.00/13.00 11.15/13.25 11.15/13.25 11.10/13.00 10.15/12.00 10.80112.00 10.75112.00 TXA036C4 TXA037C4 TXA042C4 TXA043C4 TXA048C4 TXA049C4 TXA050C4 EXPANSION TYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 35600 35600 36000 36400 37000 37000 37000 BTUH (SENSIBLE) 27000 27000 27300 28800 29300 29300 29300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1350 1350 1350 1350 SYSTEM POWER (KW) 3.30 3.30 3.30 3.39 3.41 3.41 3.41 EER / SEER (BTUIWATTHR.) 10.80112.00 10.80/12.00 10.90/12.00 10.75/12.00 10.85/12.00 10.85112.00 10.85/12.00 TXC030C4 TXC030D4 TXC031C4 TXC031134 TXC035C4 TXC035D4 TXC036C4 EXPANSION TYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 34600 34600 35000 35000 34600 34600 35600 BTUH (SENSIBLE) 25300 25300 25700 25700 25300 25300 27000 INDOOR AIRFLOW (CFM) 1100 1100 1100 1100 1100 1100 1200 SYSTEM POWER (KW) 3.22 3.22 3.24 3.24 3.22 3.22 3.30 EER / SEER (BTUANATTHR.) 10.75112.00 10.75/12.00 10.80112.00 10.80/12.00 10.75/12.00 10.75112.00 10.80/12.00 TXC03604 TXC037C4 TXC042C4 TXC043C4 TXC048C4 TXC049C4 TXC050C4 EXPANSION TYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 35600 35600 36000 36400 37000 37000 37000 BTUH (SENSIBLE) 27000 27000 27300 28800 29300 29300 29300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1350 1350 1350 1350 SYSTEM POWER (KW) 3.30 3.30 3.30 3.39 3.41 3.41 3.41 EER / SEER (BTU/WATT-HR.) 10.80/12.00 10.80/12.00 10.90/12.00 10.75/12.00 10.85/12.00 10.85/12.00 10.85/12.00 TXH033A4 TXH041A4 EXPANSION TYPE CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 35400 37000 BTUH (SENSIBLE) 26500 29600 INDOOR AIRFLOW (CFM) 1125 1350 SYSTEM POWER (KW) 3.26 3.41 EER / SEER (BTUIWATT-HR.) 10.85/12.25 10.85/12.00 4TTX4036A With Air Handlers 4TEE3F31A 4TEE3F37A 4TEE3F40A 4TEE3F49A 4TEP3F30A 4TEP3F36A 4TEP3F42A EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 35400 35800 37800 38000 34200 35200 36600 BTUH (SENSIBLE) 27200 27100 29100 29100 24000 26700 29200 INDOOR AIRFLOW (CFM) 1220 1160 1200 1200 940 1200 1350 SYSTEM POWER (KW) 3.19 3.06 3.09 3.05 3.08 3.23 3.33 EER 1 SEER (BTU/WATT-HR.) 11.10/13.00 11.70114.00 12.25/14.50 12.45/14.75 11.10/13.00 10.90112.75 11.00113.00 4TEP3F48A TVF03OA14 TVF03SA14 TWE03OC14 TWE036C14 TWE042C14 TWE048C14 EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 35 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 37000 35600 36400 33400 35200 36400 36800 • BTUH (SENSIBLE) 29500 26800 28000 23400 27200 29300 29600 INDOOR AIRFLOW (CFM) 1350 1125 1200 945 1200 1350 1350 SYSTEM POWER (KW) 3.26 3.30 3.35 3.08 3.26 3.39 3.44 EER 1 SEER (BTUIWATTHR.) 11.35/13.25 10.80112.25 10.85112.25 10.85/12.25 10.80112.25 10.75112.00 10.70/12.00 2 Notes: O Certified in accordance with A.R.I. Standard 210/240 4TTX4036-SUB-100.00 4TTX4036A With Furnaces & Coils TDD060R9V3 TDD060R9V3 TDD060R9V3 TDD060R9V3 TDD080R9V3 TDD080R9V3 TDD0809V3 +TXH033A4 +TXH041A4 +RXC03lS3 +RXC03653 +TXH033A4 +TXH041A4 +RXC03lS3 EXPANSION TYPE CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 CHG TO 65 TXV-NB R/UNNGS (COOLING) O BTUH (TOTAL) 36000 37000 35800 36600 35800 36800 35600 BTUH (SENSIBLE) 27700 28400 27400 27900 26900 27700 26600 INDOOR AIRFLOW (CFM) 1200 1200 1200 1200 1125 1140 1120 SYSTEM POWER (KW) 3.19 3.19 3.17 3.16 3.13 3.15 3.11 EER / SEER (BTU/WATT-HR.) 11.30113.00 11.60113.25 11.30113.25 11.60/13.75 11.45113.00 11.70113.50 11.45113.50 TDD080R9V3 TOD1001119VS TDD100R9V5 TDD100R9V5 TUY060R9V3 TDY0601119V3 TOY06OR9V3 +RXC036S3 +TXH033A4 +TXH041A4 +RXC037S3 +TXH033A4 +TXH041A4 +RXC03lS3 EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB CHG TO 65 CHG TO 65 TXV-NB R/UINGS (COOLING) OO BTUH (TOTAL) 36600 35800 37200 37000 35600 36400 35600 BTUH (SENSIBLE) 27300 27000 28600 28100 26400 26800 26300 INDOOR AIRFLOW (CFM) 1130 1130 1200 1180 1080 1070 1090 SYSTEM POWER (KW) 3.10 3.13 3.11 3.05 3.11 3.11 3.11 EER I SEER (BTU/WATT-HR.) 11.80/14.00 11.45/13.25 11.95114.00 12.15114.50 11.45/13.00 11.70113.50 11.45113.50 TDY06011190 TING8011190 TDY080R9V3 TOY0801119V3 TDY080R9V3 TOY100R9V4 TDY100R9V4 +RXC036S3 +TXH033A4 +TXH041A4 +RXC03lS3 +RXC036S3 +TXH033A4 +TXH041A4 EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65' CHG TO 65 RAnNGS (COOLING) O BTUH (TOTAL) 36200 35400 36400 35200 36000 35400 36400 BTUH (SENSIBLE) 26600 26400 27000 25600 26100 26000 26600 INDOOR AIRFLOW (CFM) 1085 1100 1100 1050 1050 1050 1050 SYSTEM POWER (KW) 3.09 3.16 3.18 3.14 3.13 3.08 3.11 EER / SEER (BTUIWATT-HR.) 11.70114.00 11.20113.00 11.45113.00 11.20113.00 11.50113.50 11.50113.25 11.70113.50 TOY100R9V4 TUD060R9V3 TUD060R9V3 TUD060R9V3 TUD060R9V3 TUD080R9V3 TUD080R9V3 +RXC037S3 +TXH033A4 +TXH041A4 +RXC03lS3 +RXC036S3. +TXH033A4 +TXH041A4 EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 CHG TO 65 R/UINGS (COOLING) O • BTUH (TOTAL) 36200 36000 37000 35800 36600 36000 36800 BTUH (SENSIBLE) 26300 28100 28800 27400 27900 27700 28200 INDOOR AIRFLOW (CFM) 1050 1250 1250 1200 1200 1200 1200 SYSTEM POWER (KW) 3.07 3.27 3.27 3.20 3.20 3.20 3.20 EER / SEER (BTU/WATT--HR.) 11.80/14.00 11.00/12.50 11.30113.00 11.20113.00 11.45/13.59 11.25113.00 11.50113.25 TUD080R9V3 TUD080RSV3 TUD100R9VS TUD100R9V5 TUD100RW5 TUY060R9V3 TUY060R9V3 +RXC03lS3 +RXC036S3 +TXH033A4 +TXH041A4 +RXC037S3 +TXH033A4 +TXH041A4 EXPANSION TYPE TXV-NB TXV-NB CHG TO 65 CHG TO 65 TXV-NB CHG TO 65 CHG TO 65 RARNGS (COOLING) O BTUH (TOTAL) 35800 36600 36200 37200 37200 35400 36200 BTUH (SENSIBLE) 27400 27900 27900 28600 27600 26100 26300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1200 1110 1070 1025 SYSTEM POWER (KW) 3.20 3.21 3.12 3.14 3.14 3.12 3.07 EER / SEER (BTU/WATT-HR.) 11.20113.00 11.40113.25 11.60113.50 11.85113.75 11.85/1400 11.35/13.00 11.80113.50 TUY060R9V3 TUY060R9V3 TUY080R9V3 TUY090R9V3 TUY080N8V3 TUY080R9V3 TUY100R9V4 +RXC031S3 +RXC036S3 +TXH033A4 +TXHO41A4 +RXC03JS3 +RXC036S3 +TXH033A4 EXPANSION TYPE TXV-NB TXV-NB CHG TO 65 CHG TO 65 TXV-k9 TXV-NB CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 35400 36200 35200 36200 35400 36200 35600 BTUH (SENSIBLE) 25800 26300 25400 26300 25700 26200 26200 INDOOR AIRFLOW (CFM) 1050 1050 1000 1025 1046 1040 1050 SYSTEM POWER (KW) 3.11 3.09 3.06 3.07 3.0E 3.08 3.07 EER 1 SEER (BTU/WATT--HR.) 11.40113.50 11.70114.00 11.50113.25 11.80113.50 11.50/13.50 11.75114.00 11.60/13.50 TUY100R9V4 TUY100R9V4 +TXH041A4 +RXC037S3 EXPANSION TYPE CHG TO 65 TXV-NB RAnNGS (COOLING) O BTUH (TOTAL) 36400 36400 BTUH (SENSIBLE) • 26600 26600 INDOOR AIRFLOW (CFM) 1050 1060 SYSTEM POWER (KW) 3.07 3.01 EER / SEER (BTUIWATT-HR.) 11.85113.75 12.10114.50 4TTX4036-SUB-100.00 Notes: O Certified in accordance with A.R.I. Standard 210/240. 3 L_J • Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 DuratuffT"" Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The ClimatuffO compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff® compressor is standard with a 10 year limited warranty. 4 P �F�EO T09Ai� ' c+ TRANE' Condenser Gail The Spine Fin_M coil shall be continuously wrapped, corr)sion resistant all alumi- num with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides ow airflow resistance and efficient heat transfer. The coil is pro- tected on all taur sides by louvered panels and has a 10 year limited warranty. Low Ambiert Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator dafrost control permits operation to 40°F. The addition of an evaporator dbfrost control with TXV permits low ambient cooling to 30°F. Accessorie.a Thermostats — Heating/Cooling (manual anc automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Coling. Outdoor Ttermostat — Supplemental heat outdocr ambient lockout from 46 to –10°F Trane A business of American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trane.com design and specifications without notice.